  1. Nasal airway responses to nasal continuous positive airway pressure breathing: An in-vivo pilot study.

    PubMed

    White, David E; Bartley, Jim; Shakeel, Muhammad; Nates, Roy J; Hankin, Robin K S

    2016-06-14

    The nasal cycle, through variation in nasal airflow partitioning, allows the upper airway to accommodate the contrasting demands of air conditioning and removal of entrapped air contaminants. The purpose of this study was to investigate the influence of nasal continuous positive airway pressure (nCPAP) breathing has on both nasal airflow partitioning and nasal geometry. Using a custom-made nasal mask, twenty healthy participants had the airflow in each naris measured during normal nasal breathing followed by nCPAP breathing. Eight participants also underwent magnetic resonance imaging (MRI) of the nasal region during spontaneous nasal breathing, and then nCPAP breathing over a range of air pressures. During nCPAP breathing, a simultaneous reduction in airflow through the patent airway together with a corresponding increase in airway flow within the congested nasal airway were observed in sixteen of the twenty participants. Nasal airflow resistance is inversely proportional to airway cross-sectional area. MRI data analysis during nCPAP breathing confirmed airway cross-sectional area reduced along the patent airway while the congested airway experienced an increase in this parameter. During awake breathing, nCPAP disturbs the normal inter-nasal airflow partitioning. This could partially explain the adverse nasal drying symptoms frequently reported by many users of this therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance.

    PubMed

    Richards, G N; Cistulli, P A; Ungar, R G; Berthon-Jones, M; Sullivan, C E

    1996-07-01

    Nasal congestion, dry nose and throat, and sore throat affect approximately 40% of patients using nasal continuous positive airway pressure (CPAP). The mechanisms causing nasal symptoms are unclear, but mouth leaks causing high unidirectional nasal airflow may be important. We conducted a study to investigate the effects of mouth leak and the influence of humidification on nasal resistance in normal subjects. Nasal resistance was measured with posterior rhinomanometry in six normal subjects who deliberately produced a mouth leak for 10 min while using nasal CPAP. Nasal resistance was measured regularly for 20 min after the challenge. A series of tests were performed using air at differing temperatures and humidities. There was no change in nasal resistance when subjects breathed through their noses while on CPAP, but a mouth leak caused a large increase in resistance (at a flow of 0.5 L/s) from a baseline mean of 2.21 cm H2O/L/s to a maximum mean of 7.52 cm H2O/L/s at 1 min after the challenge. Use of a cold passover humidifier caused little change in the response (maximum mean: 8.27 cm H2O/L/s), but a hot water bath humidifier greatly attenuated the magnitude (maximum mean: 4.02 cm H2O/L/s) and duration of the response. Mouth leak with nasal CPAP leads to high unidirectional nasal airflow, which causes a large increase in nasal resistance. This response can be largely prevented by fully humidifying the inspired air.

  3. Hydrocolloid dressing in preventing nasal trauma secondary to nasal continuous positive airway pressure in preterm infants

    PubMed Central

    Xie, Li- hua

    2014-01-01

    BACKGROUND: Continuous positive airway pressure (CPAP) with nasal devices (nCPAP) is widely used in the respiratory management of newborns. The present study aimed to compare the incidence of nasal trauma secondary to nasal continuous positive airway pressure (nCPAP) protected with or without hydrocolloid dressing in preterm infants. METHODS: This prospective controlled study was performed in the neonatal intensive care unit (NICU) of the Children’s Hospital of Hunan Province from March 1, 2010 to June 31, 2010. A total of 65 infants, 46 males and 19 females, were recruited in this study. Their average gestational age was 32.6 weeks (range 28–37 weeks). The infants were randomly divided into clinical trial group (group A, n=33) and control group (group B, n=32). Paraffin oil was smeared around the nostrils before inserting prongs in group B; the infants in group A were covered on the infant’s nostrils surface with hydrocolloid dressing (hydrocolloid dressing, 1.8 mm thick, 90029T, 3M Company, Minnesota, USA) with a size of 2–3 cm cutting two holes adapted to the nose and nostrils. The nostrils of those infants were inspected daily during nCPAP support until they were weaned off nCPAP. RESULTS: Nine infants (2 in group A and 7 in group B) developed nasal injury during nCPAP support. The Chi-square test revealed that there was a statistically significant difference (P=0.01) in the incidence of nasal injury between groups A and B. CONCLUSION: The study demonstrated that hydrocolloid dressing significantly decreased the incidence and the severity of nasal injury. PMID:25225588

  4. Hydrocolloid dressing in preventing nasal trauma secondary to nasal continuous positive airway pressure in preterm infants.

    PubMed

    Xie, Li-Hua

    2014-01-01

    Continuous positive airway pressure (CPAP) with nasal devices (nCPAP) is widely used in the respiratory management of newborns. The present study aimed to compare the incidence of nasal trauma secondary to nasal continuous positive airway pressure (nCPAP) protected with or without hydrocolloid dressing in preterm infants. This prospective controlled study was performed in the neonatal intensive care unit (NICU) of the Children's Hospital of Hunan Province from March 1, 2010 to June 31, 2010. A total of 65 infants, 46 males and 19 females, were recruited in this study. Their average gestational age was 32.6 weeks (range 28-37 weeks). The infants were randomly divided into clinical trial group (group A, n=33) and control group (group B, n=32). Paraffin oil was smeared around the nostrils before inserting prongs in group B; the infants in group A were covered on the infant's nostrils surface with hydrocolloid dressing (hydrocolloid dressing, 1.8 mm thick, 90029T, 3M Company, Minnesota, USA) with a size of 2-3 cm cutting two holes adapted to the nose and nostrils. The nostrils of those infants were inspected daily during nCPAP support until they were weaned off nCPAP. Nine infants (2 in group A and 7 in group B) developed nasal injury during nCPAP support. The Chi-square test revealed that there was a statistically significant difference (P=0.01) in the incidence of nasal injury between groups A and B. The study demonstrated that hydrocolloid dressing significantly decreased the incidence and the severity of nasal injury.

  5. Nasal deformities resulting from flow driver continuous positive airway pressure.

    PubMed Central

    Robertson, N J; McCarthy, L S; Hamilton, P A; Moss, A L

    1996-01-01

    Over a period of six months, seven cases were documented of trauma to the nose as a result of flow driver continuous positive airway pressure in babies of very low birthweight (VLBW). There was a complication rate of 20% in the babies who required it. Deformities consisted of columella nasi necrosis which can occur within three days, flaring of nostrils which worsens with duration of continuous positive airway pressure, and snubbing of the nose which persists after prolonged continuous positive airway pressure. These complications should be preventable by modifications to the mechanism and method of use. Images PMID:8976689

  6. Comparison of nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure treatments using parametric survival models.

    PubMed

    Baneshi, Mohammad-Reza; Bahmanbijari, Bahareh; Mahdian, Reza; Haji-Maghsoodi, Saeide; Nikbakht, Roya

    2014-04-01

    The Cox model is the dominant tool in clinical trials to compare treatment options. This model does not specify any specific form to the hazard function. On the other hand, parametric models allow the researcher to consider an appropriate shape of hazard function for the event of interest. The aim of this article is to compare performance of Cox and parametric models. We used data collected in a prospective clinical trial that aimed to compare performance of nasal intermittent positive pressure ventilation (NIPPV) and nasal continuous positive airway pressure (NCPAP) treatments in terms of survival of newborn infants who had respiratory distress syndrome (RDS). Performance of Cox, exponential, Weibull, and log-logistic models were compared in terms of goodness of fit. Fitting the Cox model, we have seen that infants who received NCPAP were 4.23 (Hazard Ratio= 4.23, 95% Confidence Interval: 1.87-9.59) times more likely to fail than those received NIPPV (P=0.001). Adequacy of the exponential model was rejected. We have seen a decreasing hazard rate over time, in both treatment groups. This decrease was sharper in NCPAP group. Akiake information criterion corresponded to the log-logistic model and was lower than all other models followed by Weibull model. Our results demonstrate the benefit of parametric survival models over traditional Cox regression model in terms of modeling of shape of hazard function. We saw a decreasing hazard that confirms the flexibility of parametric models in terms of the modeling of hazard rate.

  7. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    PubMed

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Heated Humidified High Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure as Primary Mode of Respiratory Support for Respiratory Distress in Preterm Infants.

    PubMed

    Hegde, Deeparaj; Mondkar, Jayashree; Panchal, Harshad; Manerkar, Swati; Jasani, Bonny; Kabra, Nandkishor

    2016-02-01

    To compare the outcomes of preterm infants with respiratory distress initiated on either Heated Humidified High Flow Nasal Cannula or Nasal Continuous Positive Airway Pressure as a primary mode of respiratory support. Prospective observational cohort study. Tertiary care level III neonatal intensive care unit. 88 preterm infants between 28 to 34 weeks of gestation with mild to moderate respiratory distress within 6 hours of birth. Eligible infants were treated either with Heated Humidified High Flow Nasal Cannula (n=46) or Nasal Continuous Positive Airway Pressure (n=42). Need for mechanical ventilation within 72 hrs of initiating support. Baseline demographic characteristics were comparable between the two groups. There was no difference in the requirement of mechanical ventilation between Heated Humidified High Flow Nasal Cannula (19.5%) and Nasal Continuous Positive Airway Pressure (26.2%) groups [RD-0.74 (95% CI 0.34-1.62; P =0.46)]. Moderate or severe nasal trauma occurred less frequently with Heated Humidified High Flow Nasal Cannula (10.9%) in comparison to Nasal Continuous Positive Airway Pressure (40.5%) (P= 0.004). Heated Humidified High Flow Nasal Cannula was comparable to Nasal Continuous Positive Airway Pressure as a primary respiratory support for preterm infants with respiratory distress, with lesser incidence of nasal trauma.

  9. The use of nasal dilator strips as a placebo for trials evaluating continuous positive airway pressure

    PubMed Central

    Amaro, Aline C.S.; Duarte, Felipe H.G.; Jallad, Raquel S.; Bronstein, Marcello D.; Redline, Susan; Lorenzi-Filho, Geraldo

    2012-01-01

    OBJECTIVES: The aim of the current study was to compare the objective and subjective effects of continuous positive airway pressure to the use of nasal dilator strips in patients with acromegaly and moderate to severe obstructive sleep apnea. METHODS: We studied 12 patients with acromegaly and moderate to severe obstructive sleep apnea (male/females = 8/4, age = 52±8 ys, body mass index = 33.5±4.6 Kg/m2, apnea–hypopnea index = 38±14 events/h) who had been included in a randomized, crossover study to receive three months of treatment with continuous positive airway pressure and nasal dilator strips. All patients were evaluated at study entry and at the end of each treatment by polysomnography, and Epworth Sleepiness Scale, Pittsburgh Sleep Quality Index and treatment satisfaction questionnaires. ClinicalTrials.gov: NCT01265121 RESULTS: The apnea–hypopnea index values decreased significantly with continuous positive airway pressure treatment but did not change with the use of nasal dilator strips. All of the subjective symptoms improved with both treatments, but these improvements were significantly greater with continuous positive airway pressure than with the nasal dilator strips. CONCLUSION: The use of nasal dilator strips had a much smaller effect on the severity of obstructive sleep apnea in patients with acromegaly and moderate to severe obstructive sleep apnea in comparison to the use of continuous positive airway pressure. Moreover, the improvement in several subjective parameters without any significant objective improvement in obstructive sleep apnea resulting from the use of nasal dilator strips is compatible with a placebo effect. PMID:22666791

  10. Effect of Nasal Obstruction on Continuous Positive Airway Pressure Treatment: Computational Fluid Dynamics Analyses

    PubMed Central

    Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi

    2016-01-01

    Objective Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. Methods We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject’s CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Results Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. Conclusion This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow

  11. Effect of Nasal Obstruction on Continuous Positive Airway Pressure Treatment: Computational Fluid Dynamics Analyses.

    PubMed

    Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi

    2016-01-01

    Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject's CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow velocity was found.

  12. Effects of nasal continuous positive airway pressure therapy on partners' sexual lives.

    PubMed

    Acar, Mustafa; Kaya, Coskun; Catli, Tolgahan; Hancı, Deniz; Bolluk, Ozge; Aydin, Yunus

    2016-01-01

    To assess sexual functioning in male and female partners before and after nasal continuous positive airway pressure (CPAP) therapy in men with obstructive sleep apnea (OSA). Twenty-one male patients with moderate to severe OSA and erectile dysfunction, and their female partner, were recruited into this prospective study. Males diagnosed with OSA were treated with nasal CPAP therapy for 12 weeks. Women were assessed for sexual functioning using the Female Sexual Function Index (FSFI), and for mood status using the Beck Depression Inventory (BDI), before and after their male partner underwent nasal CPAP therapy. Sexual functioning was assessed in men using the International Index of Erectile Function (IIEF), before and after nasal CPAP therapy. After nasal CPAP therapy for OSA in men, IIEF scores were significantly higher than pre-treatment scores. Total pre- and post-treatment IIEF scores (mean ± standard deviation) were 50.28 ± 15.88 and 65.42 ± 7.47, respectively, P < 0.01. Pre- and post-treatment FSFI scores in women were 21.54 ± 6.62 and 29.94 ± 3.76, respectively, P < 0.01. Pre- and post-treatment BDI scores in women were 14.61 ± 9.69 and 12.42 ± 8.92, respectively, P < 0.01. Following treatment of men with OSA, our data indicate benefits for nasal CPAP therapy on sexual functioning in both the male and female partners. Moreover, our findings indicate that improved sexual function in women after their male partner underwent nasal CPAP also had psychological benefits.

  13. Influence of body position on the displacement of nasal prongs in preterm newborns receiving continuous positive airway pressure

    PubMed Central

    Brunherotti, Marisa Afonso Andrade; Martinez, Francisco Eulógio

    2015-01-01

    Abstract Objective: To evaluate the influence of body position on the displacement of nasal prongs in preterm infants. Methods: This prospective, randomized, crossover study enrolled infants born at a mean gestational age of 29.7±2 weeks, birth weight of 1353±280g and 2.9±2.2 days of life, submitted to continuous positive airway pressure by nasal prongs. The main outcome was the number of times that the nasal prongs were displaced following infant positioning in the following body positions: prone, right lateral, left lateral, and supine, according to a pre-established random order. Moreover, cardiorespiratory variables (respiratory rate, heart rate, and oxygen saturation) were evaluated for each body position. Data for each position were collected every 10 min, over a period of 60 min. An occurrence was defined when the nasal prongs were displaced from the nostrils after 3 min in the desired position, requiring intervention of the examiner. Results: Among the 16 studied infants, the occurrence of nasal prong displacement was only observed in the prone position (9 infants - 56.2%) and in the left lateral position (2 infants - 12.5%). The number of times that the prongs were displaced was 11 in the prone position (7 within the first 10min) and 2 in the left lateral position (1 within the first 10min). No clinically significant changes were observed in the cardiorespiratory variables. Conclusions: Maintenance of the nasal prongs to provide adequate noninvasive respiratory support was harder in the prone position. PMID:26116326

  14. [Influence of body position on the displacement of nasal prongs in preterm newborns receiving continuous positive airway pressure].

    PubMed

    Brunherotti, Marisa Afonso Andrade; Martinez, Francisco Eulógio

    2015-01-01

    To evaluate the influence of body position on the displacement of nasal prongs in preterm infants. This prospective, randomized, crossover study enrolled infants born at a mean gestational age of 29.7±2 weeks, birth weight of 1.353±280g and 2.9±2.2 days of life, submitted to continuous positive airway pressure by nasal prongs. The main outcome was the number of times that the nasal prongs were displaced following infant positioning in the following body positions: prone, right lateral, left lateral, and supine, according to a pre-established random order. Moreover, cardiorespiratory variables (respiratory rate, heart rate, and oxygen saturation) were evaluated for each body position. Data for each position were collected every 10 minutes, over a period of 60minutes. An occurrence was defined when the nasal prongs were displaced from the nostrils after 3 minutes in the desired position, requiring intervention of the examiner. Among the 16 studied infants, the occurrence of nasal prong displacement was only observed in the prone position (9 infants-56.2%) and in the left lateral position (2 infants-12.5%). The number of times that the prongs were displaced was 11 in the prone position (seven within the first 10minutes) and two in the left lateral position (one within the first 10minutes). No clinically significant changes were observed in the cardiorespiratory variables. Maintenance of the nasal prongs to provide adequate noninvasive respiratory support was harder in the prone position. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  15. Effects of nasal mask leak and heated humidification on nasal mucosa in the therapy with nasal continuous positive airway pressure (nCPAP).

    PubMed

    Fischer, Yvonne; Keck, Tilman; Leiacker, Richard; Rozsasi, Ajnacska; Rettinger, Gerhard; Gruen, Philipp M

    2008-11-01

    The purpose of this study was to determine the objective short-term influence of nasal continuous positive airway pressure (nCPAP) therapy, nasal mask leak (NML) and heated humidifiers (HH) to nasal conditioning of spontaneously breathing subjects. This was a prospective, non-randomized, non-blinded day-time study. Eighteen healthy subjects were enrolled in the study. All subjects received nCPAP therapy for 60 min in three different conditions successively: (1) nCPAP without humidification, (2) nCPAP with a defined leakage of nasal mask (slashed circle 28.3 mm2) and (3) nCPAP with HH. Nasal humidity and temperature were measured in the anterior turbinate area using a miniaturized thermocouple and a relative humidity sensor. The measurements were accomplished at the beginning of therapy, after 60, 120 and 180 min. Absolute humidity (aH) in the anterior turbinate area decreased significantly (p = 0.0075) from 17.41 +/- 3.81 mg/l (baseline) to 15.27 +/- 2.21 mg/l (nCPAP alone). With attachment of a NML, aH decreased from 15.27 mg/l not significantly (p = 0.058) to 13.77 +/- 2.28 mg/l (nCPAP and NML) compared to nCPAP alone. After addition of heated humidification to nCPAP, aH increased again from 13.77 mg/l significantly (p = 0.042) to 15.29 +/- 3.51 mg/l (nCPAP and HH) compared to aH (nCPAP+NML). No difference was found between aH (nCPAP and HH) and aH (nCPAP alone). Airway temperature did not change significantly after application of nCPAP alone, nCPAP and NML, and nCPAP and HH. These data indicate that nCPAP therapy with NML tends to have more remarkable reduction of the nasal humidity than nCPAP therapy without NML. nCPAP with heated humidifier is able to compensate the dehydration effects induced by nCPAP therapy with NML by increasing the aH at the anterior turbinate area to the levels observed during breathing with nCPAP alone.

  16. Effects of Heated Humidification and Topical Steroids on Compliance, Nasal Symptoms, and Quality of Life in Patients with Obstructive Sleep Apnea Syndrome Using Nasal Continuous Positive Airway Pressure

    PubMed Central

    Ryan, Silke; Doherty, Liam S.; Nolan, Geraldine M.; McNicholas, Walter T.

    2009-01-01

    Background: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. Methods: 125 patients with the established diagnosis of OSAS (apnea/hypopnea index ≥ 10/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. Results: There was no difference in compliance between groups after 4 weeks (dry: 5.21 ± 1.66 h/night, fluticasone: 5.66 ± 1.68, humidifier: 5.21 ± 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. Conclusion: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered. Citation: Ryan S; Doherty LS; Nolan GM; McNicholas WT. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal

  17. Prophylactic nasal continuous positive airways pressure for preventing morbidity and mortality in very preterm infants.

    PubMed

    Subramaniam, P; Henderson-Smart, D J; Davis, P G

    2005-07-20

    Cohort studies (Avery 1987; Jonsson 1997) have suggested that early post-natal nasal continuous positive airways pressure (CPAP) may be beneficial in reducing the need for intubation and intermittent positive pressure ventilation, and in preventing chronic lung disease in preterm or low birth weight infants. To determine if prophylactic nasal CPAP commenced soon after birth regardless of respiratory status in the very preterm or very low birth weight infant reduces the use of IPPV and the incidence of chronic lung disease (CLD) without adverse effects. The search was updated in April 2005. The standard search strategy of the Neonatal Review Group was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Library Issue 1 2005, MEDLINE 1966-April 2005, previous reviews including cross references, abstracts, conferences, symposia, proceedings, expert informants, journal hand searching mainly in the English language. All trials using random or quasi-random patient allocation of very preterm infants < 32 weeks gestation and / or < 1500 gms at birth were eligible. Comparison had to be between prophylactic nasal CPAP commencing soon after birth regardless of the respiratory status of the infant compared with "standard" methods of treatment where CPAP or IPPV is used for a defined respiratory condition. Standard methods of the Cochrane Collaboration and its Neonatal Review Group, including independent assessment of trial quality and extraction of data by each author, were used. Data were analysed using relative risk (RR). Meta-analysis was performed using a fixed effects model. There are no statistically significant differences in any of the outcomes studied in either of the eligible trials (Han 1987; Sandri 2004) reporting on 82 and 230 infants respectively. In Han 1987 there are trends towards increases in the incidence of BPD at 28 days [RR 2.27 (0.77, 6.65)], death [RR 3.63 (0.42, 31.08)] and any IVH [RR 2.18 (0.84, 5.62)] in the CPAP group

  18. [Two cases of chronic atelectasis that improved through use of nasal continuous positive pressure].

    PubMed

    Tsuchiya, Michiko; Katsuki, Yuko; Enokibori, Toru; Ninomiya, Kiyoshi; Fujimura, Naoki

    2007-06-01

    We observed improvements in two cases of chronic atelectasis through use of nasal continuous positive airway pressure (nCPAP). Case 1 suffered from middle lobe syndrome accompanied by chronic atelectasis resistant to medical treatment. Case 2 suffered from respiratory failure caused by chronic atelectasis and airway infection complications thereof following a total pneumonectomy and post-pneumonectomy syndrome. The patient was placed on artificial ventilation, and atelectasis was improved by maintaining PEEP and airflow to the atelectatic region. Following extubation we obtained good pneumatization using nCPAP. nCPAP has been reported as effective not only in cases of sleep apnea, but also for cardiogenic pulmonary edema and post-operative atelectasis; we believe it holds great promise for chronic atelectasis as well.

  19. Mouth breathing in obstructive sleep apnea prior to and during nasal continuous positive airway pressure.

    PubMed

    Ruhle, Karl Heinz; Nilius, Georg

    2008-01-01

    Patients with obstructive sleep apnea syndrome (OSAS) often complain of dryness of mouth and throat prior to and during nasal continuous positive airway pressure (nCPAP). It is believed that this is due to mouth breathing (MB). However, the association between mouth breathing and apneas/hypopneas and the effect of CPAP on MB has not been studied. The purpose of the present study was, therefore, to assess the frequency and duration of episodes of MB prior to and during treatment with nCPAP. MB was recorded prior to and during nCPAP with a closely fitting mouth mask connected to a pneumotachograph and nasal flow was measured via nasal prongs. MB episodes were expressed as the number of events divided by total sleep time x 60, to give the MB event index per hour of sleep. MB time divided by total sleep time x 60 was calculated in minutes to get the MB time index per hour of sleep. Eleven male patients with OSAS (mean age 57.9 +/- 8.3 years, body mass index 30.2 +/- 3.8) were recruited to the study. Prior to nCPAP, the apnea/hypopnea index was 55.8 +/- 26 and decreased during nCPAP to 8.0 +/- 3.4. The lowest SaO2 measured was 82.9 +/- 4.7%, and increased to 87.5 +/- 2.7% under nCPAP. The mean nCPAP was 7.8 +/- 1.6 cm H2O. MB event index per hour of sleep decreased from 35.2 +/- 19.7 prior to treatment to 5.0 +/- 5.2 under nCPAP (p < 0.01). In 52.2 +/- 27.4% of obstructive respiratory events, MB started at the end of an apnea/hypopnea episode, decreasing to 8.5 +/- 12.5% with nCPAP treatment. MB time index per hour of sleep was reduced from 13.5 +/- 10.2 min prior to treatment to 4.6 +/- 5.5 min under nCPAP (p < 0.05). In OSAS patients, MB episodes often appear at the termination of an apnea/hypopnea episode. In many cases, MB episodes can be markedly reduced by nCPAP treatment. When patients on nCPAP complain of dry mouth, appropriate measurements should be performed to verify MB. 2007 S. Karger AG, Basel.

  20. Effects of flow amplitudes on intraprong pressures during bubble versus ventilator-generated nasal continuous positive airway pressure in premature infants.

    PubMed

    Kahn, Doron J; Habib, Robert H; Courtney, Sherry E

    2008-11-01

    The goal were to characterize the flow dependence of bubble nasal continuous positive airway pressure delivery in a cohort of preterm infants and to compare the actual (delivered) intraprong continuous positive airway pressure with the intended (set) nasal continuous positive airway pressure for both ventilator-generated nasal continuous positive airway pressure and bubble nasal continuous positive airway pressure delivery. A range of set values and constant flow rates were studied in the same preterm infants. For 12 premature infants of <1500 g (birth weight: 1140 +/- 267 g; gestational age: 28.5 +/- 1.9 weeks; study age: 12.9 +/- 8 days; all mean +/- SD), intraprong pressures were measured at 3 increasing flow settings, repeated for set nasal continuous positive airway pressures (or desired immersion depths) of 4 and 6 cm H(2)O. Next, intraprong pressures were measured at bubble nasal continuous positive airway pressure expiratory tubing submersion depths and ventilator-generated nasal continuous positive airway pressure set expiratory pressures of 2, 3, 4, 5, and 7 cm H(2)O while the flow rate was held constant. Actual (delivered) intraprong pressure during bubble nasal continuous positive airway pressure delivery was highly flow dependent and increased as the flow rate increased. During ventilator-generated nasal continuous positive airway pressure delivery, actual pressure at the nasal prongs closely approximated the pressure set at the ventilator. During bubble nasal continuous positive airway pressure delivery at constant flow rate, the average delivered prong pressure was 1.3 cm H(2)O (range: 0.5-2.2 cm H(2)O) higher than that set through submersion of the expiratory tubing, and the relative difference between the set and actual pressures increased at lesser immersion depths. Prong pressure during bubble nasal continuous positive airway pressure delivery is highly variable and depends on the interaction of submersion depth and flow amplitudes.

  1. Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial.

    PubMed

    Chandrasekaran, Aparna; Thukral, Anu; Jeeva Sankar, M; Agarwal, Ramesh; Paul, Vinod K; Deorari, Ashok K

    2017-03-01

    The objective of this study was to compare the efficacy and safety of continuous positive airway pressure (CPAP) delivered using nasal masks with binasal prongs. We randomly allocated 72 neonates between 26 and 32 weeks gestation to receive bubble CPAP by either nasal mask (n = 37) or short binasal prongs (n = 35). Primary outcome was mean FiO2 requirement at 6, 12 and 24 h of CPAP initiation and the area under curve (AUC) of FiO2 against time during the first 24 h (FiO2 AUC0-24). Secondary outcomes were the incidence of CPAP failure and nasal trauma. FiO2 requirement at 6, 12 and 24 h (mean (SD); 25 (5.8) vs. 27.9 (8); 23.8 (4.5) vs. 25.4 (6.8) and 22.6 (6.8) vs. 22.7 (3.3)) as well as FiO2 AUC0-24 (584.0 (117.8) vs. 610.6 (123.6)) were similar between the groups. There was no difference in the incidence of CPAP failure (14 vs. 20%; relative risk 0.67; 95% confidence interval 0.24-1.93). Incidence of severe nasal trauma was lower with the use of nasal masks (0 vs. 31%; p < .001). Nasal masks appear to be as efficacious as binasal prongs in providing CPAP. Masks are associated with lower risk of severe nasal trauma. CTRI2012/08/002868 What is Known? • Binasal prongs are better than single nasal and nasopharyngeal prongs for delivering continuous positive airway pressure (CPAP) in preventing need for re-intubation. • It is unclear if they are superior to newer generation nasal masks in preterm neonates requiring CPAP. What is New? • Oxygen requirement during the first 24 h of CPAP delivery is comparable with use of nasal masks and binasal prongs. • Use of nasal masks is, however, associated with significantly lower risk of severe grades of nasal injury.

  2. Mandibular Advancement Device as a Comparable Treatment to Nasal Continuous Positive Airway Pressure for Positional Obstructive Sleep Apnea

    PubMed Central

    Takaesu, Yoshikazu; Tsuiki, Satoru; Kobayashi, Mina; Komada, Yoko; Nakayama, Hideaki; Inoue, Yuichi

    2016-01-01

    Study Objectives: Positional obstructive sleep apnea (P-OSA) is a clinically common phenotype of OSA, which can be treated effectively with mandibular advancement devices (MADs). We hypothesized that the efficacy of an MAD is comparable to that of nasal continuous positive airway pressure (nCPAP) in P-OSA patients. Methods: Among patients diagnosed with OSA at a single sleep center from January 2008 to May 2014, male subjects with moderate OSA were recruited and stringently categorized as having P-OSA when the ratio of their lateral apnea-hypopnea index (AHI) to supine AHI was ≤ 0.5, their lateral sleep time was > 60 minutes, and their lateral REM sleep time was longer than 10 minutes. Treatment efficacy was compared between P-OSA subjects with an MAD (n = 34) and those with nCPAP (n = 34) after matching for age, body-mass index, and baseline AHI. Results: There were no significant differences in baseline AHI (MAD: nCPAP = 20.6 ± 3.9/h: 21.3 ± 1.7/h, p = 0.35) or in follow-up AHI (MAD: nCPAP = 4.7 ± 3.5/h: 3.4 ± 3.7/h, p = 0.12) between the 2 treatment groups, and hence MADs lowered the AHI to the same extent as nCPAP. Conclusions: These findings suggest that an MAD is as efficacious as nCPAP for P-OSA patients. MAD treatment for this specific phenotype may be a promising patient-tailored and first-line approach to OSA. Commentary: A commentary on this article appears in this issue on page 1079. Citation: Takaesu Y, Tsuiki S, Kobayashi M, Komada Y, Nakayama H, Inoue Y. Mandibular advancement device as a comparable treatment to nasal continuous positive airway pressure for positional obstructive sleep apnea. J Clin Sleep Med 2016;12(8):1113–1119. PMID:27250814

  3. Effect of Nasal Continuous Positive Pressure on the Nostrils of Patients with Sleep Apnea Syndrome and no Previous Nasal Pathology. Predictive Factors for Compliance.

    PubMed

    Aguilar, Francina; Cisternas, Ariel; Montserrat, Josep Maria; Àvila, Manuel; Torres-López, Marta; Iranzo, Alex; Berenguer, Joan; Vilaseca, Isabel

    2016-10-01

    To evaluate the effect of continuous positive airway pressure (CPAP) on the nostrils of patients with sleep apnea-hypopnea syndrome and its impact on quality of life, and to identify predictive factors for compliance. Longitudinal prospective study. Thirty-six consecutive patients evaluated before and 2 months after CPAP using the following variables: clinical (eye, nose and throat [ENT] symptoms, Epworth test, anxiety/depression scales, general and rhinoconjunctivitis-specific quality of life); anatomical (ENT examination, computed tomography); functional (auditive and Eustachian tube function, nasal flow, mucociliary transport); biological (nasal cytology); and polisomnographics. The sample was divided into compliers (≥4h/d) and non-compliers (<4h/d). A significant improvement was observed in daytime sleepiness (p=0.000), anxiety (P=.006), and depression (P=.023). Nasal dryness (P=.000), increased neutrophils in nasal cytology (P=.000), and deteriorating ciliary function were evidenced, particularly in compliers. No significant differences were observed in the other variables. Baseline sleepiness was the only factor predictive of compliance. CPAP in patients without previous nasal pathology leads to an improvement in a series of clinical parameters and causes rhinitis and airway dryness. Some ENT variables worsened in compliers. Sleepiness was the only prognostic factor for poor tolerance. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Improved growth and development in premature infants managed with nasal continuous positive airway pressure.

    PubMed

    Flesher, Susan Lee; Domanico, Renee S

    2014-01-01

    Our goal was to assess the association between the use of nasal continuous positive airway pressure (NCPAP) vs. conventional ventilation (CV) in premature infants and its effects on: 1) growth in the NICU and at follow up visits 2) neurodevelopmental outcomes measured by Bayley Infant Neurodevelopmental Screener (BINS) 3) the incidence of retinopathy of prematurity (ROP) and chronic lung disease (CLD). A retrospective chart review of two groups of NICU patients was conducted. The first group was from 1/1999-12/2000 (n = 140) and was managed by CV. The second group (n = 168) was from 1/2003-12/2004 and was managed primarily by NCPAP. Categorical variables were analyzed using Pearson Chi Square. Mean numerical values were analyzed with the student t-test. There was no statistical difference between the groups in regard to 15 demographic and interventional variables. There were significant differences between the two groups in CLD (p < 0.05) and ROP (p < 0.01), mean weight at one month (p < 0.05), 9-12 months (p < 0.01) and 15-18 months (p < 0.01), length at 4-6 months (p < 0.05), 9-12 months (p < 0.05), 15-18 months (p < 0.01), and 2 years (p = .05), and in BINS scores at 9-12 months (p < 0.01) and 15-18 months (p < 0.01). Managing babies with NCPAP therapy when compared with CV, significantly increased the weight at one month which was sustained at the 9-12 month and 15-18 month visits, increased length at all follow up visits, increased BINS scores at the 9-12 month and 15-18 month visits, and decreased the incidence of ROP and CLD.

  5. Nasal nitric oxide improved by continuous positive airway pressure therapy for upper airway inflammation in obstructive sleep apnea.

    PubMed

    Hamada, Satoshi; Tatsumi, Shuji; Kobayashi, Yoshiki; Yasuba, Hirotaka

    2017-05-01

    In this report, we examined the association between obstructive sleep apnea (OSA) and upper and lower airway inflammation based on nitric oxide (NO) measurements. Study subjects included 51 consecutive participants. Sleep-disordered breathing was evaluated by a type 3 portable monitor and quantified by respiratory disturbance index (RDI). Airway inflammation was noninvasively analyzed by the measurement of nasally and orally exhaled NO; nasal value was presented as nasally exhaled NO minus orally exhaled NO. In 15 patients prescribed nasal continuous positive airway pressure (nCPAP) therapy, exhaled NO was re-evaluated in 10.7 ± 6.3 months after nCPAP therapy. Nasal NO was significantly higher in patients with severe OSA (RDI ≥ 30/h) than those with non-OSA (RDI < 10/h) (76.9 ± 26.0 ppb vs. 47.9 ± 22.0 ppb, respectively, p = 0.016) and correlated with RDI (rho = 0.36, p = 0.0099), whereas orally exhaled NO did not differ between non-OSA and OSA patients and was not correlated with RDI. In 15 patients, nasal NO after nCPAP therapy was significantly decreased than that before nCPAP therapy (81.9 ± 31.2 ppb vs. 53.7 ± 27.2 ppb, respectively, p = 0.0046); in 11 patients having good compliance to nCPAP therapy (nCPAP use >4 h per night on more than 70% of nights), this association was more remarkable. In OSA, upper but not lower airway inflammation can be increased by repetitive collapse of the upper airway. Future studies are required to determine the role of nasal NO in OSA.

  6. Nasal pillows as an alternative interface in patients with obstructive sleep apnoea syndrome initiating continuous positive airway pressure therapy.

    PubMed

    Ryan, Silke; Garvey, John F; Swan, Valerie; Behan, Renata; McNicholas, Walter T

    2011-06-01

    Side-effects directly due to the nasal mask are common in patients with obstructive sleep apnoea syndrome (OSAS) commencing continuous positive airway pressure (CPAP). Recently, nasal pillows have been designed to overcome these issues. Limited evidence exists of the benefits and effectiveness of these devices. Twenty-one patients (19 male, 49±10years) with the established diagnosis of OSAS [apnoea/hypopnoea index (AHI): 52±22] and who had a successful CPAP titration were commenced on CPAP therapy (10±2cmH2O), and randomized to 4weeks of a nasal pillow (P) and a standard nasal mask (M) in a crossover design. Outcome measures were objective compliance, AHI, quality of life, Epworth Sleepiness Score (ESS) and CPAP side-effects. There was no difference in compliance (M versus P: 5.1±1.9h versus 5.0±1.7h; P=0.701) and AHI (2.6±2.7 versus 3.0±2.9; P=0.509). Quality of life and ESS improved with CPAP, but there was no difference in the extent of improvement between both devices. Usage of nasal pillows resulted in less reported pressure on the face and more subjects found the nasal pillow the more comfortable device. However, there was no clear overall preference for either device at the end of the study (mask=57%, pillow=43%; P=0.513). The applied CPAP pressure did not correlate with compliance, AHI and ESS. Furthermore, no differences in outcome parameters were noted comparing groups with CPAP pressure <10 and ≥10cm H(2) O. Nasal pillows are equally effective in CPAP therapy, but do not generally lead to improved compliance.

  7. A multicenter randomized controlled trial comparing effectiveness of two nasal continuous positive airway pressure devices in very-low-birth-weight infants.

    PubMed

    Bober, Klaudiusz; Świetliński, Janusz; Zejda, Jan; Kornacka, Katarzyna; Pawlik, Dorota; Behrendt, Jakub; Gajewska, Elżbieta; Czyżewska, Małgorzata; Korbal, Piotr; Witalis, Janusz; Walas, Wojciech; Wilińska, Maria; Turzańska, Agnieszka; Zieliński, Grzegorz; Czeszyńska, Beata; Bachman, Thomas

    2012-03-01

    Many studies suggest nasal continuous positive airway pressure is an effective and relatively complication-free means of respiratory support in premature infants. However, only limited data exist regarding the practical aspects of nasal continuous positive airway pressure delivery, including the best way to provide the positive airway pressure. Our aim was to compare the results of treatment using two different nasal continuous positive airway pressure devices: variable flow Infant Flow and constant flow nasal continuous positive airway pressure in two different groups of very-low-birth-weight infants in a multicenter randomized controlled trial. The indication groups were elective to avoid intubation and weaning from mechanical ventilation. Twelve leading tertiary care neonatal centers in Poland. Among 276 infants (weighing between 750-1500g, with a gestational age ≤32 wks) enrolled, 51% were randomized to receive Infant Flow and 49% to receive constant flow nasal continuous positive airway pressure. Treatment success (i.e., no need for intubation/reintubation) occurred in 75% of our patients with a nonstatistically significant advantage seen with Infant Flow. The incidence of severe nasal complications and necrotizing enterocolitis were statistically significantly lower in the infants treated with Infant Flow. In our study, factors associated with elective nasal continuous positive airway pressure failure were birth weight ≤1000 g, gestational age ≤28 wks, clinical risk index for babies score >1, and PaO(2)/FIO(2) ratio of <150. Only birth weight ≤1000 g was associated with weaning failure. We found fewer severe nasal complications but no statistically significant advantage in treatment success in infants assigned to Infant Flow nasal continuous positive airway pressure compared with those assigned to constant flow nasal continuous positive airway pressure treatment. Significant risk factors of treatment failure include small size, maturity, and severity

  8. [Compliance with nasal continuous positive airway pressure (CPAP) treatment in sleep apnea-hypopnea syndrome].

    PubMed

    Alarcón, A; León, C; Maimó, A; Barbé, F; Agustí, A G; Rodríguez-Roisin, R; Granados, A; Montserrat, J M

    1995-02-01

    Ever since Sullivan introduced nighttime nasal continuous pressure on the upper airway (CPAP) in 1981 it has been the standard treatment for sleep-hypopnea syndrome (SAHS). However, CPAP is carried out at great expense and is not tolerated by all patients. Moreover, its efficacy is dependent on the degree of compliance. In this study we set out to analyze the degree of compliance with CPAP over the first 3 months of treatment in a group of 142 consecutive patients with moderate to severe SAHS (apnea-hypopnea index: 48.9 +/- 20). Diagnosis and measurement of the level of CPAP needed (9.6 +/- 2.5 cm H2O) were based on polysomnography. Eighteen (13%) patients did not return for follow-up evaluation. In the remaining 124 patients (age 54 +/- 11 years) compliance with treatment was evaluated by way of a sleep diary in which the patient recorded the hours CPAP was used at night; this record was compared with readings from the CPAP generator's counter. All subjects were asked about their degree of sleepiness before treatment by way of a standard questionnaire. Although most patients reported regular use of CPAP in diaries, only about 60% actually used it for longer than a mean 4.5 hours daily. The most compliant patients could not be differentiated from the least compliant with respect to degree of initial sleepiness, apnea-hypopnea-per-hour index or level of CPAP required.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Effect of ethanol on the efficacy of nasal continuous positive airway pressure as a treatment for obstructive sleep apnea.

    PubMed

    Berry, R B; Desa, M M; Light, R W

    1991-02-01

    The effect of ethanol ingestion on the efficacy of nasal continuous positive airway pressure (nasal CPAP) as a treatment for the obstructive sleep apnea (OSA) syndrome was studied in ten obese male subjects undergoing this therapy. On the first night of polysomnography, the lowest level of CPAP that maintained airway patency was determined (critical level). On the second (control) night (C), subjects slept the entire night on this level of CPAP. On the third night (E), subjects ingested either 1.5 ml/kg (part A, N = 6) or 2.0 ml/kg (part B, N = 4) of 50 percent ethanol (100 proof vodka) over one half-hour starting 1 h before bedtime. A serum ethanol level was obtained at bedtime (part A: 63.7 +/- 17.3 mg/dl; part B: 108.6 +/- 20.6 mg/dl), and subjects were monitored on the critical level of CPAP. Comparison of nights C and E for parts A + B showed no difference in total sleep time (TST) or the amount of different sleep stages as an absolute time or a percentage of TST except that there was more stage 2 (as a percent of TST) on E nights. The apnea + hypopnea index and C and E nights did not differ and was quite low (3.6 +/- 3.7/h vs 1.9 +/- 2.7/h). Similarly, ethanol ingestion did not increase the number of desaturations to at or below 90 and 85 percent, or lower the mean arterial oxygen saturation in NREM or REM sleep. Analysis of parts A and B separately also showed no differences with respect to the apnea + hypopnea index or the number of desaturations on control and ethanol nights. We conclude that acute moderate ethanol ingestion does not decrease the efficacy of an optimum level of nasal CPAP.

  10. Comparison of a high-flow humidified nasal cannula to nasal continuous positive airway pressure in children with acute bronchiolitis: experience in a pediatric intensive care unit.

    PubMed

    Metge, Prune; Grimaldi, Céline; Hassid, Sophie; Thomachot, Laurent; Loundou, Anderson; Martin, Claude; Michel, Fabrice

    2014-07-01

    The objective of the current study is to compare the use of a nasal continuous positive airway pressure (nCPAP) to a high-flow humidified nasal cannula (HFNC) in infants with acute bronchiolitis, who were admitted to a pediatric intensive care unit (PICU) during two consecutive seasons. We retrospectively reviewed the medical records of all infants admitted to a PICU at a tertiary care French hospital during the bronchiolitis seasons of 2010/11 and 2011/12. Infants admitted to the PICU, who required noninvasive respiratory support, were included. The first noninvasive respiratory support modality was nCPAP during the 2010/11 season, while HFNC was used during the 2011/2012 season. We compared the length of stay (LOS) in the PICU; the daily measure of PCO2 and pH; and the mean of the five higher values of heart rate (HR), respiratory rate (RR), FiO2, and SpO2 each day, during the first 5 days. Thirty-four children met the inclusion criteria: 19 during the first period (nCPAP group) and 15 during the second period (HFNC group). Parameters such as LOS in PICU and oxygenation were similar in the two groups. Oxygen weaning occurred during the same time for the two groups. There were no differences between the two groups for RR, HR, FiO2, and CO2 evolution. HFNC therapy failed in three patients, two of whom required invasive mechanical ventilation, versus one in the nCPAP group. We did not find a difference between HFNC and nCPAP in the management of severe bronchiolitis in our PICU. Larger prospective studies are required to confirm these findings.

  11. Successful treatment of obstructive sleep apnea with use of nasal continuous positive airway pressure in three patients with mucosal hemangiomas of the oral cavity.

    PubMed

    Kimura, K; Adlakha, A; Staats, B A; Shepard, J W

    1999-02-01

    Cysts and benign tumors are uncommon causes of obstructive sleep apnea (OSA), and surgical removal is usually favored. In patients in whom an operation poses a high risk, however, nasal continuous positive airway pressure (CPAP) may prove beneficial. We describe three patients with hemangiomas of the oral cavity in whom polysomnography revealed moderate to severe OSA. In all three patients, nasal CPAP effectively decreased sleep-related disordered breathing events and dramatically improved their sleep. To our knowledge, this is the first report of OSA associated with hemangiomas involving the upper airway. Our experience suggests that nasal CPAP therapy is effective and well tolerated in such patients.

  12. Sleep-related breathing disorders. 5. Nasal continuous positive airway pressure treatment for obstructive sleep apnoea.

    PubMed

    Grunstein, R R

    1995-10-01

    CPAP should be considered the first line of treatment in patients with moderate to severe obstructive sleep apnoea. In our centre in Sydney this generally means patients with more than 20 apnoea/hypopnoeas per hour with repeated dips in oxyhaemoglobin saturation and usually some symptomatology. Despite this first line role of nasal CPAP, recent objective studies question whether earlier enthusiastic reports on adherence to CPAP are correct. The role of technical innovations in new CPAP machines in improving usage remains to be tested. The "drop out" rate from physician selection for a CPAP trial to highly compliant user is certainly more than 50% of patients. What happens to these patients? Data from some studies suggest that surgical treatments are used, at least in the USA, but in all probability many of these patients remain untreated. The challenge in the next decade is either to improve CPAP devices to increase usage in this group or to develop other treatment options. The role of intensive inhospital "acclimatisation" to CPAP also has yet to be objectively tested. It is unclear whether "intelligent" CPAP will make huge inroads in increasing the number of patients who accept CPAP trials, prescriptions, or compliance. It will have minimal impact on patients with mask problems or claustrophobia or those who feel that CPAP is inconvenient. There is a high likelihood that it will reduce technologist workload during CPAP titration studies. "Intelligent" CPAP may help to reduce total overnight mouth leakage and therefore reduce nasal side effects. The current expense of developing such devices will mean that they are unlikely to supersede much cheaper standard "one pressure" CPAP machines in the next few years.

  13. Efficacy of Home Single-Channel Nasal Pressure for Recommending Continuous Positive Airway Pressure Treatment in Sleep Apnea

    PubMed Central

    Masa, Juan F.; Duran-Cantolla, Joaquin; Capote, Francisco; Cabello, Marta; Abad, Jorge; Garcia-Rio, Francisco; Ferrer, Antoni; Fortuna, Ana M.; Gonzalez-Mangado, Nicolas; de la Peña, Monica; Aizpuru, Felipe; Barbe, Ferran; Montserrat, Jose M.; Larrateguy, Luis D.; de Castro, Jorge Rey; Garcia-Ledesma, Estefania; Corral, Jaime; Martin-Vicente, Maria J.; Martinez-Null, Cristina; Egea, Carlos; Cancelo, Laura; García-Díaz, Emilio; Carmona-Bernal, Carmen; Sánchez-Armengol, Ángeles; Mayos, Merche; Miralda, Rosa M; Troncoso, Maria F.; Gonzalez, Monica; Martinez-Martinez, Marian; Cantalejo, Olga; Piérola, Javier; Vigil, Laura; Embid, Cristina; del Mar Centelles, Mireia; Prieto, Teresa Ramírez; Rojo, Blas; Lores, Vanesa

    2015-01-01

    Introduction: Unlike other prevalent diseases, obstructive sleep apnea (OSA) has no simple tool for diagnosis and therapeutic decision-making in primary healthcare. Home single-channel nasal pressure (HNP) may be an alternative to polysomnography for diagnosis but its use in therapeutic decisions has yet to be explored. Objectives: To ascertain whether an automatically scored HNP apnea-hypopnea index (AHI), used alone to recommend continuous positive airway pressure (CPAP) treatment, agrees with decisions made by a specialist using polysomnography and several clinical variables. Methods: Patients referred by primary care physicians for OSA suspicion underwent randomized polysomnography and HNP. We analyzed the total sample and both more and less symptomatic subgroups for Bland and Altman plots to explore AHI agreement; receiver operating characteristic curves to establish area under the curve (AUC) measurements for CPAP recommendation; and therapeutic decision efficacy for several HNP AHI cutoff points. Results: Of the 787 randomized patients, 35 (4%) were lost, 378 (48%) formed the more symptomatic and 374 (48%) the less symptomatic subgroups. AHI bias and agreement limits were 5.8 ± 39.6 for the total sample, 5.3 ± 38.7 for the more symptomatic, and 6 ± 40.2 for the less symptomatic subgroups. The AUC were 0.826 for the total sample, 0.903 for the more symptomatic, and 0.772 for the less symptomatic subgroups. In the more symptomatic subgroup, 70% of patients could be correctly treated with CPAP. Conclusion: Automatic home single-channel nasal pressure scoring can correctly recommend CPAP treatment in most of more symptomatic patients with OSA suspicion. Our results suggest that this device may be an interesting tool in initial OSA management for primary care physicians, although future studies in a primary care setting are necessary. Clinical Trials Information: Clinicaltrial.gov identifier: NCT01347398. Citation: Masa JF, Duran-Cantolla J, Capote F, Cabello

  14. Effect of nasal continuous positive airway pressure during sleep on 24-hour blood pressure in obstructive sleep apnea.

    PubMed

    Wilcox, I; Grunstein, R R; Hedner, J A; Doyle, J; Collins, F L; Fletcher, P J; Kelly, D T; Sullivan, C E

    1993-09-01

    Ambulatory blood pressure (BP) was measured noninvasively (Oxford Medilog ABP) at 15-minute intervals for 24 hours before and after 8 weeks of treatment with nasal continuous positive airway pressure (nCPAP) in 19 men with obstructive sleep apnea (OSA). We included both normotensive and hypertensive patients, but hypertensives were studied after withdrawal of antihypertensive drugs. Ambulatory BP before and after treatment was compared using patients as their own controls. Treatment with nCPAP was successfully established in 14 of the 19 patients (74%). Blood pressure fell significantly in patients who were successfully treated: 24-hour mean BP (systolic/diastolic) decreased from 141 +/- 18/89 +/- 11 mm Hg to 134 +/- 19/85 +/- 13 mm Hg (p < 0.05). The reduction in 24-hour mean systolic BP occurred during both day and night, but a significant fall in mean diastolic BP was only observed during the day. The mean blood pressure fell in both normotensive and hypertensive patients. Patients who were inadequately treated with nCPAP had no reduction in mean 24-hour BP. Effective treatment of sleep apnea with nCPAP was associated with a significant fall in both systolic and diastolic BP independent of changes in body weight or alcohol consumption, suggesting that sleep apnea was an independent factor contributing to elevated nighttime and daytime BP in these patients.

  15. Effects of nasal continuous positive airway pressure and oxygen supplementation on norepinephrine kinetics and cardiovascular responses in obstructive sleep apnea.

    PubMed

    Mills, Paul J; Kennedy, Brian P; Loredo, Jose S; Dimsdale, Joel E; Ziegler, Michael G

    2006-01-01

    Obstructive sleep apnea (OSA) is characterized by noradrenergic activation. Nasal continuous positive airway pressure (CPAP) is the treatment of choice and has been shown to effectively reduce elevated norepinephrine (NE) levels. This study examined whether the reduction in NE after CPAP is due to an increase in NE clearance and/or a decrease of NE release rate. Fifty CPAP-naive OSA patients with an apnea-hypopnea index >15 were studied. NE clearance and release rates, circulating NE levels, urinary NE excretion, and blood pressure and heart rate were determined before and after 14 days of CPAP, placebo CPAP (CPAP administered at ineffective pressure), or oxygen supplementation. CPAP led to a significant increase in NE clearance (P < or = 0.01), as well as decreases in plasma NE levels (P < or = 0.018) and daytime (P < 0.001) and nighttime (P < 0.05) NE excretion. NE release rate was unchanged with treatment. Systolic (P < or = 0.013) and diastolic (P < or = 0.026) blood pressure and heart rate (P < or = 0.014) were decreased in response to CPAP but not in response to oxygen or placebo CPAP treatment. Posttreatment systolic blood pressure was best predicted by pretreatment systolic blood pressure and posttreatment NE clearance and release rate (P < 0.01). The findings indicate that one of the mechanisms through which CPAP reduces NE levels is through an increase in the clearance of NE from the circulation.

  16. The Impact of Obstructive Sleep Apnoea and Nasal Continuous Positive Airway Pressure on Circulating Ischaemia-Modified Albumin Concentrations

    PubMed Central

    Uygur, Firat; Tanriverdi, Hakan; Can, Murat; Ornek, Tacettin; Erboy, Fatma; Altinsoy, Bulent; Atalay, Figen; Damar, Murat; Kokturk, Furuzan; Tor, Meltem

    2016-01-01

    The aim of the present study was to evaluate the impact of obstructive sleep apnoea syndrome (OSAS) and the effects of nasal continuous positive airway pressure (CPAP) on circulating ischaemia-modified albumin (IMA) concentrations. The study included 97 newly diagnosed OSAS patients and 30 nonapnoeic controls. Blood samples were obtained in the morning after polysomnography. After 3 months of CPAP treatment, 31 patients with moderate-severe OSAS were reassessed for serum IMA concentrations. Significantly higher serum IMA concentrations were measured in the OSAS group than in the control group [0.518 ± 0.091 absorbance units (ABSU), 0.415 ± 0.068 ABSU, P < 0.001]. Serum IMA concentrations correlated significantly with the apnoea-hypopnoea index, mean SaO2, desaturation index, and C-reactive protein concentrations. Multiple logistic regression analyses showed that OSAS increased the serum IMA concentration independent of age, sex, body mass index, smoking habit, and cardiovascular disease. After 3 months of treatment with CPAP, OSAS patients had significantly lower serum IMA concentrations (0.555 ± 0.062 ABSU to 0.431 ± 0.063 ABSU, P < 0.001). The results showed that OSAS is associated with elevated concentrations of IMA, which can be reversed by effective CPAP treatment. PMID:26903714

  17. The Impact of Obstructive Sleep Apnoea and Nasal Continuous Positive Airway Pressure on Circulating Ischaemia-Modified Albumin Concentrations.

    PubMed

    Uygur, Firat; Tanriverdi, Hakan; Can, Murat; Ornek, Tacettin; Erboy, Fatma; Altinsoy, Bulent; Atalay, Figen; Damar, Murat; Kokturk, Furuzan; Tor, Meltem

    2016-01-01

    The aim of the present study was to evaluate the impact of obstructive sleep apnoea syndrome (OSAS) and the effects of nasal continuous positive airway pressure (CPAP) on circulating ischaemia-modified albumin (IMA) concentrations. The study included 97 newly diagnosed OSAS patients and 30 nonapnoeic controls. Blood samples were obtained in the morning after polysomnography. After 3 months of CPAP treatment, 31 patients with moderate-severe OSAS were reassessed for serum IMA concentrations. Significantly higher serum IMA concentrations were measured in the OSAS group than in the control group [0.518 ± 0.091 absorbance units (ABSU), 0.415 ± 0.068 ABSU, P < 0.001]. Serum IMA concentrations correlated significantly with the apnoea-hypopnoea index, mean SaO2, desaturation index, and C-reactive protein concentrations. Multiple logistic regression analyses showed that OSAS increased the serum IMA concentration independent of age, sex, body mass index, smoking habit, and cardiovascular disease. After 3 months of treatment with CPAP, OSAS patients had significantly lower serum IMA concentrations (0.555 ± 0.062 ABSU to 0.431 ± 0.063 ABSU, P < 0.001). The results showed that OSAS is associated with elevated concentrations of IMA, which can be reversed by effective CPAP treatment.

  18. Long-term effects of treatment with nasal continuous positive airway pressure on lung function in patients with overlap syndrome.

    PubMed

    de Miguel, Javier; Cabello, Jorge; Sánchez-Alarcos, José M F; Alvarez-Sala, Rudolfo; Espinós, Domingo; Alvarez-Sala, José L

    2002-03-01

    We assessed the effects of chronic nasal continuous positive airway pressure (CPAP) therapy on lung function in a series of unselected patients with overlap syndrome, and we determined whether there were differences in the response induced by CPAP between hypercapnic (PaCO2 > or =45 mm Hg) and eucapnic patients with overlap syndrome. The study population included 55 unselected patients (48 men, mean age of 58.5 +/- 10.5 years) with a concurrent diagnosis of chronic obstructive pulmonary disease (COPD) and obstructive sleep apnea-hypopnea syndrome (OSAHS) who had been referred to the Department of Pulmonology of our hospital over 2 consecutive years and in whom work-up studies resulted in the prescription of nasal CPAP therapy. An apnea-hypopnea index (AHI) greater than or equal to 10 in the cardiorespiratory polygraphy was required for the diagnosis of OSAHS. A forced expiratory volume in one second (FEV1) less than 80% and FEV1-forced vital capacity (FVC) ratio less than 70% of the reference values were required for the diagnosis of COPD. Control lung function studies and arterial blood gas measurements were performed at 6 and 18 months of CPAP therapy. These patients with overlap syndrome accounted for 28.5% of all patients with OSAHS treated with CPAP during the study period. The mean AHI was 37.3 +/- 26.1 and the mean CPAP level 7.3 +/- 1.3 cm H2O. Thirty-three patients were hypercapnic (PaCO2 > or = 45 mm Hg) and 22 eucapnic. The hypercapnic group had higher AHI value (44.3 +/- 26.9) than the eucapnic group (28.6 +/- 21.9) (P < 0.05). After 6 months of CPAP therapy, there were statistically significant increases in PaO2, FEV1, and FVC, accompanied by significant decreases in PaCO2, serum bicarbonate levels, and alveolar-arterial oxygen difference. Response of overlap syndrome patients to CPAP therapy was superior in the hypercapnic group, particularly in relation to improvement of arterial blood gases. However, statistically significant differences in all

  19. The effect of nasal surgery on continuous positive airway pressure device use and therapeutic treatment pressures: a systematic review and meta-analysis.

    PubMed

    Camacho, Macario; Riaz, Muhammad; Capasso, Robson; Ruoff, Chad M; Guilleminault, Christian; Kushida, Clete A; Certal, Victor

    2015-02-01

    The relationship between nasal surgery and its effect on continuous positive airway pressure (CPAP) device therapeutic treatment pressures and CPAP device use has not been previously systematically examined. To conduct a systematic review and meta-analysis evaluating the effect of isolated nasal surgery on therapeutic CPAP device pressures and use in adults with obstructive sleep apnea (OSA). MEDLINE, Scopus, Web of Science, and The Cochrane Library were searched through July 15, 2014. The MOOSE consensus statement and PRISMA statement were followed. Eighteen studies (279 patients) reported CPAP data after isolated nasal surgery. Seven studies (82 patients) reported preoperative and postoperative mean therapeutic CPAP device pressures and standard deviations (SD), which reduced from 11.6 ± 2.2 to 9.5 ± 2.0 centimeters of water pressure (cwp) after nasal surgery. Pooled random effects analysis demonstrated a statistically significant pressure reduction, with a mean difference (MD) of -2.66 cwp (95% confidence interval (CI), -3.65 to -1.67); P < 0.00001. Eleven studies (153 patients) reported subjective, self-reported data for CPAP use; and a subgroup analysis demonstrated that 89.1% (57 of 64 patients) who were not using CPAP prior to nasal surgery subsequently accepted, adhered to, or tolerated it after nasal surgery. Objective, device meter-based hours of use increased in 33 patients from 3.0 ± 3.1 to 5.5 ± 2.0 h in the short term (<6 mo of follow-up). Isolated nasal surgery in patients with OSA and nasal obstruction reduces therapeutic CPAP device pressures and the currently published literature's objective and subjective data consistently suggest that it also increases CPAP use in select patients. © 2015 Associated Professional Sleep Societies, LLC.

  20. A randomised control study comparing the Infant Flow Driver with nasal continuous positive airway pressure in preterm infants

    PubMed Central

    Mazzella, M; Bellini, C; Calevo, M; Campone, F; Massocco, D; Mezzano, P; Zullino, E; Scopesi, F; Arioni, C; Bonacci, W; Serra, G

    2001-01-01

    OBJECTIVE—To compare the effectiveness of the Infant Flow Driver (IFD) with single prong nasal continuous positive airway pressure (nCPAP) in preterm neonates affected by respiratory distress syndrome.
DESIGN—Randomised controlled study.
PATIENTS—Between September 1997 and March 1999, 36 preterm infants who were eligible for CPAP treatment were randomly selected for either nCPAP or IFD and studied prospectively for changes in oxygen requirement and/or respiratory rate. The requirement for mechanical ventilation, complications of treatment, and effects on mid-term outcome were also evaluated.
RESULTS—Use of the IFD had a significantly beneficial effect on both oxygen requirement and respiratory rate (p < 0.0001) when compared with nCPAP. Moreover, O2 requirement and respiratory rate were significantly decreased by four hours (p < 0.001 and p < 0.03 respectively). The probability of remaining supplementary oxygen free over the first 48 hours of treatment was significantly higher in patients treated with the IFD than with nCPAP (p < 0.02). IFD treated patients had a higher success (weaning) rate (94% v 72%) and shorter duration of treatment (49.3 (31) v 56 (29.7) hours respectively; mean (SD)), although the difference was not significant.
CONCLUSIONS—IFD appears to be a feasible device for managing respiratory distress syndrome in preterm infants, and benefits may be had with regard to oxygen requirement and respiratory rate when compared with nCPAP. The trend towards reduced requirement for mechanical ventilation, shorter clinical recovery time, and shorter duration of treatment requires further evaluation in a multicentre randomised clinical trial.

 PMID:11517199

  1. Elective nasal continuous positive airway pressure to support respiration after prolonged ventilation in infants after congenital cardiac surgery

    PubMed Central

    Gandhi, Hemang; Mishra, Amit; Thosani, Rajesh; Acharya, Himanshu; Shah, Ritesh; Surti, Jigar; Sarvaia, Alpesh

    2017-01-01

    Background: We sought to compare the effectiveness of oxygen (O2) treatment administered by an O2 mask and nasal continuous positive airway pressure (NCPAP) in infants after congenital cardiac surgery. Methods: In this retrospective observational study, 54 infants undergoing corrective cardiac surgery were enrolled. According to the anesthesiologist's preference, the patients ventilated for more than 48 h were either put on NCPAP or O2 mask immediately after extubation. From pre-extubation to 24 h after treatment, arterial blood gas and hemodynamic data were measured. Results: After 24 h of NCPAP institution, the patients showed a significant improvement in oxygenation compared to O2 mask group. Respiratory rate (per minute) decreased from 31.67 ± 4.55 to 24.31 ± 3.69 (P < 0.0001), PO2 (mmHg) increased from 112.12 ± 22.83 to 185.74 ± 14.81 (P < 0.0001), and PCO2 (mmHg) decreased from 42.88 ± 5.01 to 37.00 ± 7.22 (P < 0.0076) in patients on NCPAP. In this group, mean pediatric cardiac surgical Intensive Care Unit (PCSICU) stay was 4.72 ± 1.60 days, with only 2 (11.11%) patients requiring re-intubation. Conclusion: NCPAP can be used safely and effectively in infants undergoing congenital cardiac surgery to improve oxygenation/ventilation. It also reduces the work of breathing, PCSICU stay, and may reduce the likelihood of re-intubation. PMID:28163425

  2. Efficacy of home single-channel nasal pressure for recommending continuous positive airway pressure treatment in sleep apnea.

    PubMed

    Masa, Juan F; Duran-Cantolla, Joaquin; Capote, Francisco; Cabello, Marta; Abad, Jorge; Garcia-Rio, Francisco; Ferrer, Antoni; Fortuna, Ana M; Gonzalez-Mangado, Nicolas; de la Peña, Monica; Aizpuru, Felipe; Barbe, Ferran; Montserrat, Jose M

    2015-01-01

    Unlike other prevalent diseases, obstructive sleep apnea (OSA) has no simple tool for diagnosis and therapeutic decision-making in primary healthcare. Home single-channel nasal pressure (HNP) may be an alternative to polysomnography for diagnosis but its use in therapeutic decisions has yet to be explored. To ascertain whether an automatically scored HNP apnea-hypopnea index (AHI), used alone to recommend continuous positive airway pressure (CPAP) treatment, agrees with decisions made by a specialist using polysomnography and several clinical variables. Patients referred by primary care physicians for OSA suspicion underwent randomized polysomnography and HNP. We analyzed the total sample and both more and less symptomatic subgroups for Bland and Altman plots to explore AHI agreement; receiver operating characteristic curves to establish area under the curve (AUC) measurements for CPAP recommendation; and therapeutic decision efficacy for several HNP AHI cutoff points. Of the 787 randomized patients, 35 (4%) were lost, 378 (48%) formed the more symptomatic and 374 (48%) the less symptomatic subgroups. AHI bias and agreement limits were 5.8 ± 39.6 for the total sample, 5.3 ± 38.7 for the more symptomatic, and 6 ± 40.2 for the less symptomatic subgroups. The AUC were 0.826 for the total sample, 0.903 for the more symptomatic, and 0.772 for the less symptomatic subgroups. In the more symptomatic subgroup, 70% of patients could be correctly treated with CPAP. Automatic HNP scoring can correctly recommend CPAP treatment in most of more symptomatic patients with OSA suspicion. Our results suggest that this device may be an interesting tool in initial OSA management for primary care physicians, although future studies in a primary care setting are necessary. Clinicaltrial.gov identifier: NCT01347398. © 2014 Associated Professional Sleep Societies, LLC.

  3. The Effect of Nasal Surgery on Continuous Positive Airway Pressure Device Use and Therapeutic Treatment Pressures: A Systematic Review and Meta-Analysis

    PubMed Central

    Camacho, Macario; Riaz, Muhammad; Capasso, Robson; Ruoff, Chad M.; Guilleminault, Christian; Kushida, Clete A.; Certal, Victor

    2015-01-01

    Background: The relationship between nasal surgery and its effect on continuous positive airway pressure (CPAP) device therapeutic treatment pressures and CPAP device use has not been previously systematically examined. Study Objectives: To conduct a systematic review and meta-analysis evaluating the effect of isolated nasal surgery on therapeutic CPAP device pressures and use in adults with obstructive sleep apnea. Methods: MEDLINE, Scopus, Web of Science, and The Cochrane Library were searched through July 15, 2014. The MOOSE consensus statement and PRISMA statement were followed. Results: Eighteen studies (279 patients) reported CPAP data after isolated nasal surgery. Seven studies (82 patients) reported preoperative and postoperative mean therapeutic CPAP device pressures and standard deviations, which reduced from 11.6 ± 2.2 to 9.5 ± 2.0 centimeters of water pressure (cwp) after nasal surgery. Pooled random effects analysis demonstrated a statistically significant pressure reduction, with a mean difference of −2.66 cwp (95% confidence intervals, −3.65 to −1.67); P < 0.00001. Eleven studies (153 patients) described subjective, self-reported data for CPAP use; and a subgroup analysis demonstrated that 89.1% (57 of 64 patients) who were not using CPAP prior to nasal surgery subsequently accepted, adhered to, or tolerated it after nasal surgery. Objective, device meter-based hours of use increased in 33 patients from 3.0 ± 3.1 to 5.5 ± 2.0 h in the short term (< 6 mo of follow-up). Conclusion: Isolated nasal surgery in patients with obstructive sleep apnea and nasal obstruction reduces therapeutic CPAP device pressures and the currently published literature's objective and subjective data consistently suggest that it also increases CPAP use in select patients. Citation: Camacho M, Riaz M, Capasso R, Ruoff CM, Guilleminault C, Kushida CA, Certal V. The effect of nasal surgery on continuous positive airway pressure device use and therapeutic treatment

  4. A randomised controlled trial of two methods of delivering nasal continuous positive airway pressure after extubation to infants weighing less than 1000 g: binasal (Hudson) versus single nasal prongs

    PubMed Central

    Davis, P; Davies, M; Faber, B

    2001-01-01

    OBJECTIVES—Primary: to determine whether nasal continuous positive airway pressure (CPAP) delivered through binasal prongs results in a greater proportion of extremely low birthweight infants being successfully extubated, after a period of intermittent positive pressure ventilation, than nasal CPAP delivered by a single nasal prong. Secondary: to evaluate the effect of mode of delivery of nasal CPAP after extubation on the need for endotracheal reintubation, weight gain, rates of feeding intolerance, sepsis, suspected sepsis, cranial ultrasound abnormalities, retinopathy of prematurity, chronic lung disease, and the duration of assisted ventilation and care in the tertiary neonatal unit.
DESIGN AND SETTING—Randomised, controlled, clinical trial conducted at the neonatal intensive care unit of the Royal Women's Hospital, Melbourne, Australia.
PATIENTS—Infants of birth weight less than 1000 g, ventilated, requiring < 50% oxygen and ventilator rate less than or equal to 20/minute, and considered by the clinical management team to be ready for extubation.
INTERVENTION—Infants were randomly allocated to receive nasal CPAP delivered through binasal (Hudson) prongs or a single nasal prong.
PRIMARY OUTCOME MEASURE—Failure of extubation as defined by the following criteria: (a) apnoea (more than one episode/hour over a six hour period or one episode requiring bag and mask ventilation); (b) absolute increase in oxygen requirement greater than 15% above that required before extubation; (c) respiratory acidosis (pH < 7.25 with PCO2 > 6.67 kPa).
RESULTS—Ten of the 41 (24%) infants randomised to binasal prongs reached predetermined failure criteria compared with 26 of the 46(57%) infants randomised to a single nasal prong (p = 0.005). Four of 17 (24%) infants of birth weight less than 800 g extubated to binasal prongs reached failure criteria compared with 14 of 16 (88%) extubated to a single nasal prong (p < 0.001). There were no significant differences in

  5. Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak.

    PubMed

    Bakker, Jessie P; Neill, Alister M; Campbell, Angela J

    2012-09-01

    This single-blinded, randomized, controlled pilot study aimed to investigate whether there is a difference between nasal and oronasal masks in therapeutic continuous positive airway pressure (CPAP) requirement, residual disease, or leak when treating obstructive sleep apnea (OSA) and if differences were related to measures of upper airway size. Patients with severe OSA currently using CPAP at ≥4 h/night with a nasal mask were examined (including Mallampati scale, incisal relationship, and mandibular protrusion) and then randomized to receive auto-positive airway pressure (PAP) or fixed CPAP at a manually titrated pressure for 1 week each at home, with immediate crossover. Within each week, a nasal mask and two oronasal masks were to be used for two or three nights each in random order. Data were downloaded from the device. Twelve patients completed the trial (mean ± SD AHI 59.8 ± 28.6 events/h; CPAP 11.1 ± 3.2 cmH(2)O; BMI 37.7 ± 5.0 kg/m(2)). During auto-PAP, the median 95th percentile pressure delivered with all masks was within 0.5 cmH(2)O (p > 0.05). During CPAP, median residual AHI was 0.61 (IQR = 1.18) for the nasal mask, 1.70 (IQR = 4.04) for oronasal mask 1, and 2.48 (IQR = 3.74) for oronasal mask 2 (p = 0.03). The 95th percentile leak was lowest with the nasal mask during both CPAP and auto-PAP (both p < 0.01). Differences in pressure or residual disease were not related to measures of upper airway shape or body habitus. In obese OSA patients changing from a nasal to oronasal mask increased leak and residual AHI but did not affect the therapeutic pressure requirement. The findings of the current study highlight mask leak as the major difficulty in the use of oronasal masks.

  6. Acute effects of nasal continuous positive airway pressure on 24-hour blood pressure and catecholamines in patients with obstructive sleep apnea.

    PubMed

    Minemura, H; Akashiba, T; Yamamoto, H; Akahoshi, T; Kosaka, N; Horie, T

    1998-12-01

    To assess the acute effects of nasal continuous positive airway pressure (CPAP) on the 24-hour blood pressure and the secretion of catecholamines in urine and plasma, we investigated the changes in the 24-hour blood pressure and urinary and plasma concentrations of epinephrine (E) and norepinephrine (NE) in 26 men with obstructive sleep apnea (OSA) with and without nasal CPAP. Nasal CPAP resulted in significant decreases in the daytime diastolic pressure (from 86 +/-16 mmHg to 83+/-12 mmHg), the nighttime diastolic pressure (from 81+/-12 mmHg to 77+/-9 mmHg) and the nighttime systolic pressures (from 125+/-15 mmHg to 120+/-10 mmHg). There was no significant difference between patients with and without CPAP in the daytime or nighttime urinary E level, but patients who received CPAP showed a significant decrease in daytime urinary NE level (from 156+/-112 microg/14h to 119+/-101 microg/14h) and nighttime urinary NE level (from 143+/-91 microg/10h to 112+/-65 microg/10h). The morning plasma level of NE also decreased (from 371+/-181 pg/ml to 273 +/-148 pg/ml) in patients who received nasal CPAP (p<0.02), but the plasma level of E remained unchanged. There were no correlations between PSG parameters and the reductions in blood pressure and the catecholamine levels induced by nasal CPAP. These findings suggest that OSA contributes, at least in part, to the development of systemic hypertension by increasing sympathetic nervous activity.

  7. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series

    PubMed Central

    Ng, Justin R.; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G.; Chai-Coetzer, Ching Li; McEvoy, R. Doug; Antic, Nick

    2016-01-01

    Study Objectives: The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. Methods: We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. Results: The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m2) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. Conclusions: If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Ng JR, Aiyappan V, Mercer J, Catcheside PG, Chai-Coetzer CL, McEvoy RD, Antic N. Choosing an oronasal mask to deliver continuous positive airway pressure may cause more upper airway obstruction or lead to higher continuous positive airway pressure requirements than a nasal

  8. Nasal bi-level positive airway pressure (BiPAP) versus nasal continuous positive airway pressure (CPAP) in preterm infants ≤32 weeks: A retrospective cohort study.

    PubMed

    Rong, Zhi-Hui; Li, Wen-Bin; Liu, Wei; Cai, Bao-Huan; Wang, Jing; Yang, Min; Li, Wei; Chang, Li-Wen

    2016-05-01

    To investigate whether Bi-level positive airway pressure (BiPAP), compared with nasal continuous positive airway pressure (CPAP), is a more effective therapeutic strategy in preterm infants ≤32 weeks. All inborn infants between 26(+1) and 32(+6) weeks' gestation, admitted to the neonatal intensive care unit (NICU ) of Tongji Medical Hospital between 1 January, 2010 and 31 December, 2011 (the 2010-2011 cohort or CPAP cohort) and between 1 January, 2012 and 31 December, 2013 (the 2012-2013 cohort or BiPAP cohort), were retrospectively identified. The primary outcome was intubation in infants < 72 h of age; secondary outcomes were mortality and the incidence of bronchopulmonary dysplasia (BPD). There were 213 in the 2010-2011 cohort and 243 infants in the 2012-2013 cohort. There were fewer infants intubated within the first 72 h of age in the 2012-2013 cohort than in the 2010-2011 cohort (15% vs. 23%, P < 0.05). Of the infants who received some form of positive airway pressure, 12/94 (13%) of infants on BiPAP versus 23/74 (31%) on CPAP were subsequently intubated (P < 0.01). There was no difference in the incidence of moderate and severe BPD between the two groups (7% vs. 8%, P=0.52). In this retrospective cohort study, we found BiPAP, compared with CPAP, reduced the need for intubation within the first 72 h of age. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  9. Amelioration of vascular endothelial dysfunction in obstructive sleep apnea syndrome by nasal continuous positive airway pressure--possible involvement of nitric oxide and asymmetric NG, NG-dimethylarginine.

    PubMed

    Ohike, Yumiko; Kozaki, Koichi; Iijima, Katsuya; Eto, Masato; Kojima, Taro; Ohga, Eijiro; Santa, Tomofumi; Imai, Kazuhiro; Hashimoto, Masayoshi; Yoshizumi, Masao; Ouchi, Yasuyoshi

    2005-02-01

    Asymmetric NG,NG-dimethylarginine (ADMA) is an endogenous inhibitor of endothelial nitric oxide (NO) synthase and its plasma concentration is elevated in patients with cardiovascular risk factors, including hyperlipidemia, hypertension, diabetes, and hyperhomocysteinemia. Obstructive sleep apnea syndrome (OSAS) has been attracting attention as a risk factor for cardiovascular disorders because it often accompanies hypertension, obesity, glucose impairment, and dyslipidemia, all of which are factors in metabolic syndrome and risk factors for cardiovascular disease. In the present study, flow-mediated vasodilatation (FMD) of the brachial artery and plasma concentrations of ADMA were measured before and after nasal continuous positive airway pressure (nCPAP) therapy, which abrogates apnea, in 10 male patients aged 36-69 years old, who were given a diagnosis of OSAS by polysomnography. The percent FMD (%FMD) improved significantly from 3.3+/-0.3% to 5.8+/-0.4% (p<0.01) and 6.6+/-0.3% (p<0.01), before, 1 week, and 4 weeks after nCPAP, respectively. At the same time, the plasma NOx concentrations, metabolites of NO, tended to increase, but the plasma ADMA concentration decreased inversely to %FMD and NOx. A negative correlation between %FMD and plasma ADMA concentration, and a positive correlation between %FMD and plasma NOx concentrations were observed. Nasal CPAP improves endothelial function, in part by the decreasing ADMA concentration, thereby potentiating NO production.

  10. A pilot study of inhaled nitric oxide in preterm infants treated with nasal continuous positive airway pressure for respiratory distress syndrome.

    PubMed

    Lindwall, Robert; Blennow, Mats; Svensson, Mats; Jonsson, Baldvin; Berggren-Boström, Eva; Flanby, Martino; Lönnqvist, Per-Arne; Frostell, Claes; Norman, Mikael

    2005-07-01

    To explore the acute effects of inhaled nitric oxide (iNO) on oxygenation, respiratory rate, and CO2 levels in spontaneously breathing preterm infants treated with nasal continuous positive airway pressure (nCPAP) for moderate respiratory distress syndrome (RDS). Randomized, prospective, double-blind, cross-over study in the neonatal intensive care units of a university hospital. 15 infants treated for RDS, with a median gestational age of 32 weeks (27-36), birth weight 1940 g (1100-4125), and postnatal age at the beginning of study 23 h (3-91). nCPAP pressure was kept constant at 4.3 cmH2O (3.4-5.1). We examined effects on gas exchange and vital signs during a 30-min exposure to 10 ppm iNO or placebo gas (nitrogen). Before administering test gases the baseline arterial to alveolar oxygen tension ratio (aAPO2) was 0.19+/-0.06. aAPO2 remained unchanged during placebo but increased to 0.22+/-0.05 (+20%) during iNO exposure. Respiratory rate and arterial carbon dioxide tension remained unchanged, as did heart rate, blood pressure, and methemoglobin. Follow-up at 30 days of age showed no deaths, delayed morbidity, or need for supplemental oxygen. Adding 10 ppm nitric oxide to nasal CPAP treatment in preterm infants suffering from RDS results in a moderate but statistically significant improvement in oxygenation, with no effect on respiratory drive or systemic circulatory parameters.

  11. Humidified High Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure as an Initial Respiratory Support in Preterm Infants with Respiratory Distress: a Randomized, Controlled Non-Inferiority Trial

    PubMed Central

    2017-01-01

    Heated, humidified, high-flow nasal cannula (HHFNC) is frequently used as a noninvasive respiratory support for preterm infants with respiratory distress. But there are limited studies that compares HHFNC with nasal continuous positive airway pressure (nCPAP) only as the initial treatment of respiratory distress in preterm infants immediately after birth. The aim of this study is to assess the effectiveness and safety of HHFNC compared to nCPAP for the initial treatment of preterm infants with respiratory distress. Preterm infants at between 30 and 35 weeks of gestational age were randomized to HHFNC or nCPAP when they showed respiratory distress in less than 24 hours of age postnatally. Preterm infants who needed invasive respiratory supports were excluded. Primary outcome was the incidence of treatment failure (defined as need for the intubation or mechanical ventilation). Eighty-five infants were analyzed. Sixteen of 42 infants randomized to HHFNC showed treatment failure compared to 9 of 43 infants using nCPAP (Risk difference 17.17 [−1.90–36.23]; P = 0.099). In terms of the reason for treatment failure, the frequency of hypoxia was significantly higher in the HHFNC group than in the nCPAP group (P = 0.020). There was no difference between the 2 groups in terms of respiratory and clinical outcomes and complications. Although HHFNC is safe compared to nCPAP, it is not certain that HHFNC is effective compared to nCPAP non-inferiorly as an initial respiratory support in preterm infants with respiratory distress. PMID:28244292

  12. Humidified High Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure as an Initial Respiratory Support in Preterm Infants with Respiratory Distress: a Randomized, Controlled Non-Inferiority Trial.

    PubMed

    Shin, Jeonghee; Park, Kyuhee; Lee, Eun Hee; Choi, Byung Min

    2017-04-01

    Heated, humidified, high-flow nasal cannula (HHFNC) is frequently used as a noninvasive respiratory support for preterm infants with respiratory distress. But there are limited studies that compares HHFNC with nasal continuous positive airway pressure (nCPAP) only as the initial treatment of respiratory distress in preterm infants immediately after birth. The aim of this study is to assess the effectiveness and safety of HHFNC compared to nCPAP for the initial treatment of preterm infants with respiratory distress. Preterm infants at between 30 and 35 weeks of gestational age were randomized to HHFNC or nCPAP when they showed respiratory distress in less than 24 hours of age postnatally. Preterm infants who needed invasive respiratory supports were excluded. Primary outcome was the incidence of treatment failure (defined as need for the intubation or mechanical ventilation). Eighty-five infants were analyzed. Sixteen of 42 infants randomized to HHFNC showed treatment failure compared to 9 of 43 infants using nCPAP (Risk difference 17.17 [-1.90-36.23]; P = 0.099). In terms of the reason for treatment failure, the frequency of hypoxia was significantly higher in the HHFNC group than in the nCPAP group (P = 0.020). There was no difference between the 2 groups in terms of respiratory and clinical outcomes and complications. Although HHFNC is safe compared to nCPAP, it is not certain that HHFNC is effective compared to nCPAP non-inferiorly as an initial respiratory support in preterm infants with respiratory distress.

  13. Randomised prospective parallel trial of therapeutic versus subtherapeutic nasal continuous positive airway pressure on simulated steering performance in patients with obstructive sleep apnoea

    PubMed Central

    Hack, M.; Davies, R.; Mullins, R.; Choi, S. J.; Ramdassingh-Dow, S.; Jenkinson, C.; Stradling, J.

    2000-01-01

    BACKGROUND—Obstructive sleep apnoea (OSA) impairs vigilance and may lead to an increased rate of driving accidents. In uncontrolled studies accident rates and simulated steering performance improve following treatment with nasal continuous positive airway pressure (NCPAP). This study seeks to confirm the improvement in steering performance in a randomised controlled trial using subtherapeutic NCPAP as a control treatment.
METHODS—Fifty nine men with OSA (Epworth Sleepiness Score (ESS) of ⩾10, and ⩾10/h dips in SaO2 of >4% due to OSA) received therapeutic or subtherapeutic NCPAP (≈1 cm H2O) for one month. Simulated steering performance over three 30-minute "drives" was quantified as: standard deviation (SD) of road position, deterioration in SD across the drive, length of drive before "crashing", and number of off-road events. The reaction times to peripheral target stimuli during the drive were also measured.
RESULTS—Subtherapeutic NCPAP did not improve overnight >4% SaO2 dips/h compared with baseline values, thus acting as a control. The SD of the steering position improved from 0.36 to 0.21 on therapeutic NCPAP, and from 0.35 to 0.30 on subtherapeutic NCPAP (p = 0.03). Deterioration in SD of the steering position improved from 0.18to 0.06 SD/h with therapeutic NCPAP and worsened from 0.18 to 0.24 with subtherapeutic NCPAP (p = 0.04). The reaction time to target stimuli was quicker after therapeutic than after subtherapeutic NCPAP (2.3 versus 2.7 seconds, p = 0.04).
CONCLUSIONS—Therapeutic NCPAP improves steering performance and reaction time to target stimuli in patients with OSA, lending further support to the hypothesis that OSA impairs driving, increases driving accident rates, and that these improve following treatment with NCPAP.

 PMID:10679542

  14. A comparison of the effects of invasive mechanic ventilation/surfactant therapy and non-invasive nasal-continuous positive airway pressure in preterm newborns.

    PubMed

    Celik, Muhittin; Bulbul, Ali; Uslu, Sinan; Dursun, Mesut; Guran, Omer; Kıray Bas, Evrim; Arslan, Selda; Zubarioglu, Umut

    2017-08-31

    This study compared the early-term outcomes of mechanical ventilation (MV)/surfactant treatment with nasal-continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS). Data from newborns born between ≥24 and ≤32 weeks of gestation, hospitalized at our newborn intensive care unit, and diagnosed with RDS between January 2009 and February 2012 were analyzed. Of 193 newborns with RDS who were enrolled in the study, 113 were treated with nCPAP and 80 with MV at a level of 57.5% of nCPAP. Within the study group, 46.3% of the infants were female. The mean gestation of the continuous positive airway pressure (CPAP) group was 29.07 ± 1.99 weeks; that of the MV group was 28.61 ± 2.01 weeks. The birth weight was 1321.1 ± 325.4 g and 1240.3 ± 366.1 g; however, the difference between the two groups was not significant. MV was not required in 54.9% of the patients with nCPAP treatment. Bronchopulmonary dysplasia (BPD) developed in 20 (18.7%) patients in the nCPAP group and 18 (24.4%) patients in the MV group; the difference was not significant (p = .351). Between 2009 and 2012, nCPAP was used at a rate of 33.9, 70.8, 68.4, and 69%. The risk factors for developing BPD were low gestation week, duration of intubation, and proven sepsis (p = .0001, p = .004, and p = .011, respectively). Early nCPAP treatment in preterm infants (≤32 weeks of gestation) decreases both the need for MV and the use of surfactant, but without a significant effect on BPD development. (No. 2016/324).

  15. Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial

    PubMed Central

    2013-01-01

    Introduction Upper airway obstruction (UAO) is a major problem in unconscious subjects, making full face mask ventilation difficult. The mechanism of UAO in unconscious subjects shares many similarities with that of obstructive sleep apnea (OSA), especially the hypotonic upper airway seen during rapid eye movement sleep. Continuous positive airway pressure (CPAP) via nasal mask is more effective at maintaining airway patency than a full face mask in patients with OSA. We hypothesized that CPAP via nasal mask and ventilation (nCPAP) would be more effective than full face mask CPAP and ventilation (FmCPAP) for unconscious subjects, and we tested our hypothesis during induction of general anesthesia for elective surgery. Methods In total, 73 adult subjects requiring general anesthesia were randomly assigned to one of four groups: nCPAP P0, nCPAP P5, FmCPAP P0, and FmCPAP P5, where P0 and P5 represent positive end-expiratory pressure (PEEP) 0 and 5 cm H2O applied prior to induction. After apnea, ventilation was initiated with pressure control ventilation at a peak inspiratory pressure over PEEP (PIP/PEEP) of 20/0, then 20/5, and finally 20/10 cm H2O, each applied for 1 min. At each pressure setting, expired tidal volume (Vte) was calculated by using a plethysmograph device. Results The rate of effective tidal volume (Vte > estimated anatomical dead space) was higher (87.9% vs. 21.9%; P<0.01) and the median Vte was larger (6.9 vs. 0 mL/kg; P<0.01) with nCPAP than with FmCPAP. Application of CPAP prior to induction of general anesthesia did not affect Vte in either approach (nCPAP pre- vs. post-; 7.9 vs. 5.8 mL/kg, P = 0.07) (FmCPAP pre- vs. post-; 0 vs. 0 mL/kg, P = 0.11). Conclusions nCPAP produced more effective tidal volume than FmCPAP in unconscious subjects. Trial registration ClinicalTrials.gov identifier: NCT01524614. PMID:24365207

  16. Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial.

    PubMed

    Oto, Jun; Li, Qian; Kimball, William R; Wang, Jingping; Sabouri, Abdolnabi S; Harrell, Priscilla G; Kacmarek, Robert M; Jiang, Yandong

    2013-12-23

    Upper airway obstruction (UAO) is a major problem in unconscious subjects, making full face mask ventilation difficult. The mechanism of UAO in unconscious subjects shares many similarities with that of obstructive sleep apnea (OSA), especially the hypotonic upper airway seen during rapid eye movement sleep. Continuous positive airway pressure (CPAP) via nasal mask is more effective at maintaining airway patency than a full face mask in patients with OSA. We hypothesized that CPAP via nasal mask and ventilation (nCPAP) would be more effective than full face mask CPAP and ventilation (FmCPAP) for unconscious subjects, and we tested our hypothesis during induction of general anesthesia for elective surgery. In total, 73 adult subjects requiring general anesthesia were randomly assigned to one of four groups: nCPAP P0, nCPAP P5, FmCPAP P0, and FmCPAP P5, where P0 and P5 represent positive end-expiratory pressure (PEEP) 0 and 5 cm H2O applied prior to induction. After apnea, ventilation was initiated with pressure control ventilation at a peak inspiratory pressure over PEEP (PIP/PEEP) of 20/0, then 20/5, and finally 20/10 cm H2O, each applied for 1 min. At each pressure setting, expired tidal volume (Vte) was calculated by using a plethysmograph device. The rate of effective tidal volume (Vte > estimated anatomical dead space) was higher (87.9% vs. 21.9%; P<0.01) and the median Vte was larger (6.9 vs. 0 mL/kg; P<0.01) with nCPAP than with FmCPAP. Application of CPAP prior to induction of general anesthesia did not affect Vte in either approach (nCPAP pre- vs. post-; 7.9 vs. 5.8 mL/kg, P = 0.07) (FmCPAP pre- vs. post-; 0 vs. 0 mL/kg, P = 0.11). nCPAP produced more effective tidal volume than FmCPAP in unconscious subjects. ClinicalTrials.gov identifier: NCT01524614.

  17. Mandibular advancement devices vs nasal-continuous positive airway pressure in the treatment of obstructive sleep apnoea. Systematic review and meta-analysis

    PubMed Central

    Galletti, Cosimo; Galletti, Francesco; Galletti, Bruno; Galletti, Claudio; Gay-Escoda, Cosme

    2017-01-01

    Background Obstructive sleep apnoea (OSA) is a common disorder that may affect at least 2 to 4% of the adult population. Nasal-Continuous Positive Airway Pressure (N-CPAP) is today considered the gold standard for the treatment of OSA. The development of oral appliances (OAs) represents a new approach for the management of this pathology. The aim of this systematic review is to compare the efficacy of OAs and N-CPAP in the treatment of patients with mild to severe OSA. Material and Methods A PubMed-MEDLINE and Cochrane databases search of articles published between 1982 and 2016 comparing the effect of N-CPAP and OAs in OSA patients was conducted during July 2016. The studies were selected and stratified according to PRISMA and SORT criteria. The main outcome measure was post-treatment Apnoea-Hypopnoea Index (AHI) while secondary outcomes included post-treatment Epworth Score Scale (ESS) score and lowest Oxygen Saturation level. Results N-CPAP was significantly more effective in suppressing AHI than OA. Moreover, N- CPAP was significantly more effective in increasing post-treatment lowest Oxygen Saturation level than OA. However, no significant different in decreasing ESS values was found between the two treatments. Conclusions On the basis of evidence in this review it would appear appropriate to offer OA therapy to those who are unwilling or unable to persist with CPAP therapy. N-CPAP still must be considered the gold standard treatment for OSA and, therefore, OAs may be included in the list of alternative options. Key words:CPAP, obstructive sleep apnoea, oral appliances. PMID:28578372

  18. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    PubMed Central

    Valizadeh, Sousan; Hosseini, Mohammad Bagher; Asghari Jafarabadi, Mohammad; Ajoodanian, Najmeh

    2012-01-01

    Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs), massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS) treated with nasal continuous positive airway pressure (NCPAP). Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran). The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils). Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR), fraction of inspired oxygen (FiO2) and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP. PMID:25276695

  19. Effects of three month nasal continuous positive airway pressure treatment on electrocardiographic, echocardiographic and overnight polysomnographic parameters in newly diagnosed moderate/severe obstructive sleep apnea patients.

    PubMed

    Cicek, Davran; Balcioğlu, Akif Serhat; Lakadamyali, Hüseyin; Müderrisoğlu, Haldun

    2015-01-01

    The objective of the study was to determine the effects of nasal continuous positive airway pressure (nCPAP) therapy on left ventricular (LV) function and electrocardiographic parameters in newly diagnosed moderate/severe obstructive sleep apnea (OSA) patients without cardiovascular comorbidities and medical treatments. We examined 44 patients who underwent overnight polysomnography together with 24-hour Holter electrocardiography, cardiopulmonary exercise testing including heart rate recovery at 1 minute (HRR-1), echocardiography, surface electrocardiography, and those who were diagnosed with moderate/severe OSA apnea--hypopnea index ≥ 15. After 3 months of nCPAP treatment, the above-mentioned examinations were repeated. Forty-four patients completed the treatment period. Twelve weeks on effective nCPAP induced a significant increase in the mitral E/A ratio (P = 0.001), as well as reductions in isovolumic relaxation time (P = 0.001) and mitral deceleration time (DT) (P = 0.002). There were no significant differences in LV ejection fraction, LV mass index, and pulsed wave Doppler parameters. Mean heart rate was 79.2 ± 12.5 pulses/minute, maximum P-wave duration 117.5 ± 8.6 msec, P-wave dispersion (PWd) 54.6 ± 10.2 msec, corrected QT interval (QTc) 436.5 ± 40.5 msec, and QT dispersion (QTd) 46.3 ± 7.1 msec, which significantly decreased to 70.4 ± 9.6 pulses/minute (P < 0.001), 111.5 ± 8.7 msec (P < 0.001), 51.6 ± 8.9 msec (P < 0.001), 418.4 ± 31.2 msec (P < 0.001), and 33.8 ± 3.4 msec (P < 0.001), respectively. Exercise capacity at baseline determined as 10.5 ± 2.2 metabolic equivalents (METS) and HRR-1 (20.6 ± 11.7 bpm) significantly increased (12.1 ± 1.5 METS and 27.4 ± 8.6 bpm). There was no significant difference in aortic root parameters. Three-month nCPAP therapy significantly increased LV shortening fraction, with no effect on systolic function or aortic root diameters and a positive effect on heart rate, PWd, HRR-1, QTc and QTd time following

  20. Effect of adherence on daytime sleepiness, fatigue, depression and sleep quality in the obstructive sleep apnea/hypopnea syndrome patients undertaking nasal continuous positive airway pressure therapy.

    PubMed

    Wang, Yeying; Ai, Li; Luo, Jiahong; Li, Ran; Chai, Yanlin; He, Xiaojie; Cao, Yu; Li, Yongxia

    2017-01-01

    The aims of this study were to describe changes in day- and nighttime symptoms and the adherence to nasal continuous positive airway pressure (nCPAP) during the first 3-month nCPAP therapy among newly diagnosed patients with obstructive sleep apnea/hypopnea syndrome (OSAS) and to identify the effect of adherence on the changes in day- and nighttime symptoms during the first 3 months. Newly diagnosed OSAS patients were consecutively recruited from March to August 2013. Baseline clinical information and measures of the Epworth Sleepiness Scale (ESS), Fatigue Severity Scale (FSS), Zung's Self-Rating Depression Scale (SDS) and the Pittsburgh Sleep Quality Index (PSQI) at baseline and the end of 3rd, 6th, 9th and 12th week of therapy were collected. Twelve weeks' adherence was calculated as the average of each 3-week period. Mixed model was used to explore the effect of adherence to nCPAP therapy on ESS, FSS, SDS and PSQI in each 3-week phase. Seventy-six patients completed the 12-week follow-up. The mixed-effects models showed that under the control of therapy phase adherence in the range of <4 hours per night, using nCPAP could independently improve daytime sleepiness, in terms of ESS (coefficient, [95% confidence interval] unit; -4.49 [-5.62, -3.36]). Adherence at 4-6 hours per night could independently improve all variables of day- and nighttime symptoms included in this study, namely ESS -6.69 (-7.40, -5.99), FSS -6.02 (-7.14, -4.91), SDS -2.40 (-2.95, -1.85) and PSQI -0.20 (-0.52, -0.12). Further improvement in symptoms could be achieved at ≥6 hours per night using nCPAP, which was ESS -8.35 (-9.26, -7.44), FSS -10.30 (-11.78, -8.83), SDS -4.42 (-5.15, -3.68) and PSQI -0.40 (-0.82, -0.02). The interaction between adherence level and therapy phase was not significant in day- and nighttime symptoms. The effect of adherence on the above-mentioned symptoms is stable through the first 3 months. Under the control of therapy phase, the nCPAP therapy effectively

  1. In vivo efficacy of heated and non-heated humidifiers during nasal continuous positive airway pressure (nCPAP)-therapy for obstructive sleep apnoea.

    PubMed

    Wiest, G H; Fuchs, F S; Brueckl, W M; Nusko, G; Harsch, I A; Hahn, E G; Ficker, J H

    2000-04-01

    Upper airway dryness is a frequent side-effect of nasal continuous positive airway pressure therapy (nCPAP) in obstructive sleep apnoea (OSA). In this situation, heated or non-heated passover humidifiers are often added to the nCPAP-therapy. The efficacy of these two modes in terms of increasing the absolute humidity of the inspired air in vivo has so far not been established. The present investigation was therefore designed to compare various heated and non-heated passover humidifiers in terms of the their ability to increase the absolute humidity in the inspired air during nCPAP. In six healthy test individuals, nCPAP-therapy at pressures of 5 mbar and 10 mbar was simulated, and the relative humidity and temperature of the air within the tube at the junction between CPAP tube and mask were measured. In each test person, measurements were carried out both with and without the two heated (HC 100, Fischer&Paykel Inc., New Zealand and HumidAire, ResMed Ltd., Australia) and two non-heated (Oasis and Humidifier, both from Respironics Inc., U.S.A.) passover humidifiers under steady-state conditions. The absolute humidity was calculated from the relative humidity and temperature measurements. The mean (SD) absolute humidity (gm(-3)) in the steady-state was significantly (P<0.05 higher with each of the humidifiers than that calculated when no humidifier was used. The relevant figures were as follows: no humidifier: 10(-2) (1.8) gm(-3) (at 5 mbar)/9.8 (1.8) gm(-3) (at 10 mbar); Humidifier: 16.4 (0.97)/15.6 (1.26); Oasis: 17.3 (0.97)/ 16.7 (0.93); HC100: 26.5 (1.40)/26.2 (1.23); HumidAire: 31.8 (2.50)/30.9 (2.64). The mean increase in absolute humidity (in gm(-3)) with the aid of the heated humidifiers was 16.3 (5 mbar) gm(-3)/16.4 (10 mbar) gm(-3) with HC100 and 21.6/21.1 with HumidAire, and in both cases was clearly and significantly (P=0.028) higher in comparison with the non-heated humidifiers--6.2/5.8 with Humidifier and 7.2/6.9 with Oasis. In terms of the absolute

  2. In vitro validation and clinical testing of an indirect calorimetry system for ventilated preterm infants that is unaffected by endotracheal tube leaks and can be used during nasal continuous positive airway pressure.

    PubMed

    Bauer, K; Ketteler, J; Laurenz, M; Versmold, H

    2001-03-01

    Energy expenditure measurements in ventilated preterm infants are difficult because indirect calorimetry underestimates energy expenditure during gas leaks around uncuffed endotracheal tubes routinely used in preterm infants or during nasal continuous positive airway pressure (CPAP). We, therefore, developed a breath collector that simultaneously sampled expired air expelled at the ventilator outlet and escaping via the tube leak from the infant's mouth and nose. Our breath collector was combined with a proprietary calorimeter (Deltatrac II). In vitro validation was done by methanol burning (VO(2), 13.8 mL/min; VCO(2), 9.2 mL/min) during intermittent positive pressure ventilation (IPPV) with two commonly used ventilators (Sechrist IV-100B and Infant Star). Measurement error was determined at different ventilator flows, peak inspiratory pressures of 12-24 cm H(2)O, and during a complete tube leak. The mean measurement error with both ventilators was low (VO(2) +/- 3 %, VCO(2) +/- 2 %) even during a complete tube leak and did not increase with peak inspiratory pressure. The system response time was 2 min. In vivo measurements at the bedside were performed in 25 preterm infants (body weight, 537-1402 g). Energy expenditure during IPPV was 40 +/- 9 kcal/kg per day and 46 +/- 15 kcal/kg per day during nasal CPAP. The tube leak in the preterm infants studied during IPPV was 0 to 47 %, and during nasal CPAP 84 to 97 %. In conclusion, indirect calorimetry performed with our breath collector was accurate during IPPV and nasal CPAP and was unaffected by tube leaks.

  3. The sleep supine position has a major effect on optimal nasal continuous positive airway pressure : relationship with rapid eye movements and non-rapid eye movements sleep, body mass index, respiratory disturbance index, and age.

    PubMed

    Oksenberg, A; Silverberg, D S; Arons, E; Radwan, H

    1999-10-01

    To evaluate the impact of sleep position on optimal nasal continuous positive airway pressure (nCPAP [op-nCPAP]) in obstructive sleep apnea (OSA) patients and to investigate how rapid eye movements (REM) and Non-REM (NREM) sleep, body mass index (BMI), respiratory disturbance index (RDI), and age are related to this effect. Retrospective analysis. Sleep Disorders Unit at Loewenstein Hospital Rehabilitation Center. Eighty-three consecutive adult OSA patients who underwent a complete nCPAP titration. From this group, 60 patients who spent at least 30 min in both the supine (Sup) and lateral (Lat) positions and 46 patients who had data on both positions during REM and NREM sleep were included in the analysis. In most OSA patients (52; 86.7%), the recommended op-nCPAP was obtained when the patients slept in the Sup posture. The mean op-nCPAP was significantly higher in the Sup posture (10.00 +/- 2.20 cm H(2)O) than it was in the Lat posture (7.61 +/- 2.69 cm H(2)O). The op-nCPAP was significantly higher in the Sup position than it was in the Lat position in both REM and NREM sleep, as well as in the severe BMI group (BMI >/= 30) and in the less obese group (BMI < 30). Similarly, in the severe (RDI >/= 40) and less severe groups (RDI < 40), as well as in both age groups (< and > 60 years of age), the op-nCPAP was significantly higher in the Sup posture than it was in the Lat posture. Irrespective of the four parameters mentioned, the actual differences in op-nCPAP between the two body postures were almost identical, ranging between 2.31 and 2.66 cm H(2)O. For most OSA patients, the op-nCPAP level is significantly higher in the Sup position than it is in the Lat position. This is true for REM and NREM sleep, for obese and nonobese patients, for patients with different degrees of severity, and for young and old OSA patients. Since the op-nCPAP was highest in the Sup posture during REM sleep, no nCPAP titration should be considered complete without the patient having slept

  4. [Smokers develop a nasal obstruction in supine position].

    PubMed

    Gudziol, H; Krause, J; Stadeler, M; Guntinas-Lichius, O

    2011-07-01

    We found in a previous study a healthy non-smoker nose does not develop obstruction lying in supine position . We examined whether a designated smoker nose behaves consistently. 39 healthy young smokers participated. The daily consumption was Ø 21 cigarettes. 9 test positions have been realized. Acoustic rhinometry was used for the estimation of nasal volumes and the nasal minimum cross-sectional areas as parameters for nasal respiration. Additionally, blood pressure and heart rate were measured to control the cardiovascular behavior. The total nasal volume decreased significantly lying down. Only one third of the volunteers noticed this obstruction. Going upstairs all measured parameters increased. 2 min later all rhinometric parameters, the diastolic blood pressure and heart rate had reached its baseline level. Systolic blood pressure took about 4 min. A cigarette smoke-induced nasal obstruction can be demonstrated during supine position using the acoustic rhinometry. One third of smokers noted a deterioration of nasal breathing. During stairs climbing the sympathic tone is increasing followed by nasal decongestion, raised blood pressure and heart rate. If smokers complaint of nasal obstruction in lying position - whether alert or during sleep - it is advisable to lift the bed-head. In medium term a therapy of chronic rhinitis with topical corticosteroids, in longer term a smoking cessation is recommended. © Georg Thieme Verlag KG Stuttgart · New York.

  5. A multicentre, randomised controlled, non-inferiority trial, comparing high flow therapy with nasal continuous positive airway pressure as primary support for preterm infants with respiratory distress (the HIPSTER trial): study protocol.

    PubMed

    Roberts, Calum T; Owen, Louise S; Manley, Brett J; Donath, Susan M; Davis, Peter G

    2015-06-24

    High flow (HF) therapy is an increasingly popular mode of non-invasive respiratory support for preterm infants. While there is now evidence to support the use of HF to reduce extubation failure, there have been no appropriately designed and powered studies to assess the use of HF as primary respiratory support soon after birth. Our hypothesis is that HF is non-inferior to the standard treatment--nasal continuous positive airway pressure (NCPAP)--as primary respiratory support for preterm infants. The HIPSTER trial is an unblinded, international, multicentre, randomised, non-inferiority trial. Eligible infants are preterm infants of 28-36(+6) weeks' gestational age (GA) who require primary non-invasive respiratory support for respiratory distress in the first 24 h of life. Infants are randomised to treatment with either HF or NCPAP. The primary outcome is treatment failure within 72 h after randomisation, as determined by objective oxygenation, blood gas, and apnoea criteria, or the need for urgent intubation and mechanical ventilation. Secondary outcomes include the incidence of intubation, pneumothorax, bronchopulmonary dysplasia, nasal trauma, costs associated with hospital care and parental stress. With a specified non-inferiority margin of 10%, using a two-sided 95% CI and 90% power, the study requires 375 infants per group (total 750 infants). Ethical approval has been granted by the relevant human research ethics committees at The Royal Women's Hospital (13/12), The Royal Children's Hospital (33144A), The Mercy Hospital for Women (R13/34), and the South-Eastern Norway Regional Health Authority (2013/1657). The trial is currently recruiting at 9 centres in Australia and Norway. The trial results will be published in peer-reviewed international journals, and presented at national and international conferences. Australian New Zealand Clinical Trials Registry ID: ACTRN12613000303741. Published by the BMJ Publishing Group Limited. For permission to use (where not

  6. A multicentre, randomised controlled, non-inferiority trial, comparing high flow therapy with nasal continuous positive airway pressure as primary support for preterm infants with respiratory distress (the HIPSTER trial): study protocol

    PubMed Central

    Roberts, Calum T; Owen, Louise S; Manley, Brett J; Donath, Susan M; Davis, Peter G

    2015-01-01

    Introduction High flow (HF) therapy is an increasingly popular mode of non-invasive respiratory support for preterm infants. While there is now evidence to support the use of HF to reduce extubation failure, there have been no appropriately designed and powered studies to assess the use of HF as primary respiratory support soon after birth. Our hypothesis is that HF is non-inferior to the standard treatment—nasal continuous positive airway pressure (NCPAP)— as primary respiratory support for preterm infants. Methods and analysis The HIPSTER trial is an unblinded, international, multicentre, randomised, non-inferiority trial. Eligible infants are preterm infants of 28–36+6 weeks’ gestational age (GA) who require primary non-invasive respiratory support for respiratory distress in the first 24 h of life. Infants are randomised to treatment with either HF or NCPAP. The primary outcome is treatment failure within 72 h after randomisation, as determined by objective oxygenation, blood gas, and apnoea criteria, or the need for urgent intubation and mechanical ventilation. Secondary outcomes include the incidence of intubation, pneumothorax, bronchopulmonary dysplasia, nasal trauma, costs associated with hospital care and parental stress. With a specified non-inferiority margin of 10%, using a two-sided 95% CI and 90% power, the study requires 375 infants per group (total 750 infants). Ethics and dissemination Ethical approval has been granted by the relevant human research ethics committees at The Royal Women's Hospital (13/12), The Royal Children's Hospital (33144A), The Mercy Hospital for Women (R13/34), and the South-Eastern Norway Regional Health Authority (2013/1657). The trial is currently recruiting at 9 centres in Australia and Norway. The trial results will be published in peer-reviewed international journals, and presented at national and international conferences. Trial registration number Australian New Zealand Clinical Trials Registry ID: ACTRN

  7. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnea syndrome: a randomized, placebo-controlled trial on self-reported symptoms of common sleep disorders and sleep-related problems.

    PubMed

    Nikolopoulou, Maria; Byraki, Anna; Ahlberg, Jari; Heymans, Martijn W; Hamburger, H L; De Lange, Jan; Lobbezoo, Frank; Aarab, Ghizlane

    2017-03-10

    Obstructive sleep apnea syndrome (OSAS) is associated with several sleep disorders and sleep-related problems. Therefore, the aim of this study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) on self-reported symptoms of common sleep disorders and sleep-related problems in mild and moderate OSAS patients. In this randomized placebo-controlled trial sixty-four OSAS patients (52.0± 9.6 years) were randomly assigned to an MAD, nCPAP or an intra-oral placebo appliance in a parallel design. All participants filled out the validated Dutch Sleep Disorders Questionnaire (SDQ) twice: one before treatment and one after six months of treatment. With 88 questions, thirteen scales were constructed, representing common sleep disorders and sleep-related problems. Linear mixed model analyses were performed to study differences between the groups for the different SDQ scales over time. The MAD group showed significant improvements over time in symptoms corresponding with "insomnia", "excessive daytime sleepiness", "psychiatric sleep disorder", "periodic limb movements", "sleep apnea", "sleep paralysis", "daytime dysfunction", "hypnagogic hallucinations/dreaming", "restless sleep", "negative conditioning", and "automatic behaviour" (range of P values: 0.000-0.014). These improvements in symptoms were, however, not significantly different from the improvements in symptoms observed in the nCPAP and placebo groups (range of P values: 0.090-0.897). It can be concluded that there is no significant difference between MAD and nCPAP in their positive effects on self-reported symptoms of common sleep disorders and sleep-related problems in mild and moderate OSAS patients. These beneficial effects may be a result of placebo effects. This article is protected by copyright. All rights reserved.

  8. Retrograde Lacrimal Duct Airflow During Nasal Positive Pressure Ventilation

    PubMed Central

    Zandieh, Stephanie; Katz, Eliot S.

    2010-01-01

    Noninvasive ventilation is widely used for chronic respiratory failure in children with neuromuscular disorders, thus avoiding the need for tracheostomy. However, the pressures required to support ventilation in these children may be considerably higher than those necessary to treat obstructive sleep apnea. The complications of nasal positive airway pressure are numerous, including skin breakdown, conjunctivitis, nasal congestion, airway dryness, pneumothorax, and bowel obstruction. Ophthalmologic complaints are particularly common, largely attributed to an air leak in the mask. In the present case, we demonstrate, through two modalities—video and CT scan—retrograde airflow through the nasolacrimal duct causing sleep disruption and eye irritation in a profoundly hypotonic 14-month-old boy with chronic respiratory failure on bilevel ventilation during sleep. Citation: Zandieh S; Katz ES. Retrograde lacrimal duct airflow during nasal positive pressure ventilation. J Clin Sleep Med 2010;6(6):603-604. PMID:21206550

  9. Response of Preterm Infants to 2 Noninvasive Ventilatory Support Systems: Nasal CPAP and Nasal Intermittent Positive-Pressure Ventilation.

    PubMed

    Silveira, Carmen Salum Thomé; Leonardi, Kamila Maia; Melo, Ana Paula Carvalho Freire; Zaia, José Eduardo; Brunherotti, Marisa Afonso Andrade

    2015-12-01

    Noninvasive ventilation (NIV) in preterm infants is currently applied using intermittent positive pressure (2 positive-pressure levels) or in a conventional manner (one pressure level). However, there are no studies in the literature comparing the chances of failure of these NIV methods. The aim of this study was to evaluate the occurrence of failure of 2 noninvasive ventilatory support systems in preterm neonates over a period of 48 h. A randomized, prospective, clinical study was conducted on 80 newborns (gestational age < 37 weeks, birthweight < 2,500 g). The infants were randomized into 2 groups: 40 infants were treated with nasal CPAP and 40 infants with nasal intermittent positive-pressure ventilation (NIPPV). The occurrence of apnea, progression of respiratory distress, nose bleeding, and agitation was defined as ventilation failure. The need for intubation and re-intubation after failure was also observed. There were no significant differences in birth characteristics between groups. Ventilatory support failure was observed in 25 (62.5%) newborns treated with nasal CPAP and in 12 (30%) newborns treated with NIPPV, indicating an association between NIV failure and the absence of intermittent positive pressure (odds ratio [OR] 1.22, P < .05). Apnea (32.5%) was the main reason for nasal CPAP failure. After failure, 25% (OR 0.33) of the newborns receiving nasal CPAP and 12.5% (OR 0.14) receiving NIPPV required invasive mechanical ventilation. Ventilatory support failure was significantly more frequent when nasal CPAP was used. Copyright © 2015 by Daedalus Enterprises.

  10. The utility of noninvasive nasal positive pressure ventilators for optimizing oxygenation during rapid sequence intubation.

    PubMed

    Kim, Tae Hoon; Hwang, Sung Oh; Cha, Yong Sung; Kim, Oh Hyun; Lee, Kang Hyun; Kim, Hyun; Cha, Kyoung-Chul

    2016-08-01

    The objective of the study is to investigate the feasibility of noninvasive nasal positive pressure ventilation (NINPPV) for optimizing oxygenation during the rapid sequence intubation in critically ill patients. A prospective, observational study was performed in an emergency department. Noninvasive nasal positive pressure ventilation was applied in the preoxygenation step and maintained until successful intubation. A pulse oximetry (Spo2) was continuously monitored throughout the procedure and recorded 5 times. The degree of interfering was surveyed with 10-point Likert scale. Thirty patients were enrolled. The most of enrolled patients were diagnosed as pneumonia, acute heart failure, and traumatic brain injury. The Spo2 was increased to 100% (98%-100%) at the time of starting endotracheal intubation with NINPPV and maintained as 97% (95%-100%) until successful intubation (P< .001). Total apnea duration was 195 seconds (190-196). The degree of interfering intubation was 1 (0-1). Noninvasive nasal positive pressure ventilation would be useful for optimizing oxygenation during rapid sequence intubation. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Hemodynamic Effects of Nasal Intermittent Positive Pressure Ventilation in Preterm Infants

    PubMed Central

    Chang, Hung-Yang; Cheng, Kun-Shan; Lung, Hou-Ling; Li, Sung-Tse; Lin, Chien-Yu; Lee, Hung-Chang; Lee, Ching-Hsiao; Hung, Hsiao-Fang

    2016-01-01

    Abstract Nasal intermittent positive pressure ventilation (NIPPV) and nasal continuous positive airway pressure (NCPAP) have proven to be effective modes of noninvasive respiratory support in preterm infants. Although they are increasingly used in neonatal intensive care, their hemodynamic consequences have not been fully evaluated. The aim of this study was to investigate the hemodynamic changes between NIPPV and NCPAP in preterm infants. This prospective observational study enrolled clinically stable preterm infants requiring respiratory support received NCPAP and nonsynchronized NIPPV at 40/minute for 30 minutes each, in random order. Cardiac function and cerebral hemodynamics were assessed by ultrasonography after each study period. The patients continued the study ventilation during measurements. Twenty infants with a mean gestational age of 27 weeks (range, 25–32 weeks) and birth weight of 974 g were examined at a median postnatal age of 20 days (range, 9–28 days). There were no significant differences between the NCPAP and NIPPV groups in right (302 vs 292 mL/kg/min, respectively) and left ventricular output (310 vs 319 mL/kg/min, respectively), superior vena cava flow (103 vs 111 mL/kg/min, respectively), or anterior cerebral artery flow velocity. NIPPV did not have a significant effect on the hemodynamics of stable preterm infants. Future studies assessing the effect of NIPPV on circulation should focus on less stable and very preterm infants. PMID:26871833

  12. Persistent nasal symptoms and mediator release after continuous pollen exposure in an environmental challenge chamber.

    PubMed

    Okuma, Yusuke; Okamoto, Yoshitaka; Yonekura, Syuji; Iinuma, Tomohisa; Sakurai, Toshioki; Hamasaki, Sawako; Ohki, Yuji; Yamamoto, Heizaburo; Sakurai, Daiju

    2016-08-01

    Immediate- and late-phase reactions are associated with nasal symptoms of patients with allergic rhinitis. To examine the symptoms and mediators released after continuous allergen exposure in an environmental challenge chamber (ECC). Fifteen patients with Japanese cedar pollinosis were enrolled in this study and continuously exposed to cedar pollen at a concentration of 8,000 grains/m(3) for 3 hours in an ECC. Nasal function tests were performed, and nasal secretions were collected before pollen exposure (0 hour), immediately after exiting the ECC (3 hours), and 6 hours after exiting the ECC (9 hours). Symptom scores were recorded every 30 minutes in the ECC and every 3 hours after exiting the ECC. The frequency of sneezing and nose blowing also was monitored. The severity of symptoms in the ECC peaked approximately 2 hours after the beginning of pollen exposure and continued more than 6 hours after leaving the ECC. Concentrations of histamine, tryptase, interleukins 5, 3, 33, and 31, and substance P increased over time, whereas that of nasal fractional exhaled nitric oxide decreased. Various mediators are released during continuous allergen exposure, which subsequently induce persistent nasal symptoms. Effective treatment is required to control the intense inflammation observed after allergen exposure. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  13. Inhibitory Effect of Nasal Intermittent Positive Pressure Ventilation on Gastroesophageal Reflux

    PubMed Central

    Cantin, Danny; Djeddi, Djamal; Carrière, Vincent; Samson, Nathalie; Nault, Stéphanie; Jia, Wan Lu; Beck, Jennifer; Praud, Jean-Paul

    2016-01-01

    Non-invasive intermittent positive pressure ventilation can lead to esophageal insufflations and in turn to gastric distension. The fact that the latter induces transient relaxation of the lower esophageal sphincter implies that it may increase gastroesophageal refluxes. We previously reported that nasal Pressure Support Ventilation (nPSV), contrary to nasal Neurally-Adjusted Ventilatory Assist (nNAVA), triggers active inspiratory laryngeal closure. This suggests that esophageal insufflations are more frequent in nPSV than in nNAVA. The objectives of the present study were to test the hypotheses that: i) gastroesophageal refluxes are increased during nPSV compared to both control condition and nNAVA; ii) esophageal insufflations occur more frequently during nPSV than nNAVA. Polysomnographic recordings and esophageal multichannel intraluminal impedance pHmetry were performed in nine chronically instrumented newborn lambs to study gastroesophageal refluxes, esophageal insufflations, states of alertness, laryngeal closure and respiration. Recordings were repeated without sedation in control condition, nPSV (15/4 cmH2O) and nNAVA (~ 15/4 cmH2O). The number of gastroesophageal refluxes recorded over six hours, expressed as median (interquartile range), decreased during both nPSV (1 (0, 3)) and nNAVA [1 (0, 3)] compared to control condition (5 (3, 10)), (p < 0.05). Meanwhile, the esophageal insufflation index did not differ between nPSV (40 (11, 61) h-1) and nNAVA (10 (9, 56) h-1) (p = 0.8). In conclusion, nPSV and nNAVA similarly inhibit gastroesophageal refluxes in healthy newborn lambs at pressures that do not lead to gastric distension. In addition, the occurrence of esophageal insufflations is not significantly different between nPSV and nNAVA. The strong inhibitory effect of nIPPV on gastroesophageal refluxes appears identical to that reported with nasal continuous positive airway pressure. PMID:26785264

  14. Comparison of the Upper Airway Dynamics of Oronasal and Nasal Masks with Positive Airway Pressure Treatment using cine Magnetic Resonance Imaging

    PubMed Central

    Ebben, Matthew R.; Milrad, Sara; Dyke, Jonathan P.; Phillips, C. Douglas; Krieger, Ana C.

    2016-01-01

    Purpose It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine Magnetic Resonance Imaging (cMRI). Methods 10-Subjects (8-men, 2-women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10 and 15 cm of H2O, while in the supine position along the sagittal plane. Results The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p=0.016. No differences were found in the retroglossal region between mask styles. Conclusions Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region. PMID:25924934

  15. The Emergence of an Unmarkedness Effect in Mandarin Speech Errors: Nasals in a Coda Position

    ERIC Educational Resources Information Center

    Hsu, Hsiu-ling

    2011-01-01

    This study aims to explore how the markedness effect shapes Mandarin slips of the tongue with respect to nasals in syllable-final positions. Data were collected via natural speech and elicitation tasks from 35 participants' reading of 346 test items. Three hundred and eight slips in Mandarin from natural data and 360 slips from elicited data were…

  16. The emergence of an unmarkedness effect in Mandarin speech errors: nasals in a coda position.

    PubMed

    Hsu, Hsiu-ling

    2011-09-01

    This study aims to explore how the markedness effect shapes Mandarin slips of the tongue with respect to nasals in syllable-final positions. Data were collected via natural speech and elicitation tasks from 35 participants' reading of 346 test items. Three hundred and eight slips in Mandarin from natural data and 360 slips from elicited data were investigated. This study shows that there exists a strong preference for unmarked coronal nasals over marked dorsal nasals in the syllable-final position in both spontaneous and elicited Mandarin slips. This tendency toward the unmarked [n] reveals that the influence of the unmarkedness effect is present in the coda position in Mandarin slips. Interestingly, this tendency is inconsistent with that found in a previous study by Wan of Mandarin slips in the onset position, which shows a tendency for coronals to be replaced by other sounds. This suggests an onset-coda distinction occurring in Mandarin speech errors, which implies that the markedness effect works differently in distinct syllable positions. More precisely, the unmarkedness effect emerges in the coda position in Mandarin slips, leading to the occurrence of unmarked segments, whereas it submerges in the onset position, resulting in marked segments.

  17. Nasal Expiratory Positive Airway Pressure Devices (Provent) for OSA: A Systematic Review and Meta-Analysis

    PubMed Central

    Riaz, Muhammad; Certal, Victor; Nigam, Gaurav; Abdullatif, Jose; Zaghi, Soroush; Kushida, Clete A.; Camacho, Macario

    2015-01-01

    Objective. To quantify the effectiveness of nasal expiratory positive airway pressure (nasal EPAP) devices or Provent as treatment for obstructive sleep apnea (OSA). Methods. PubMed and six other databases were searched through November 15, 2015, without language limitations. Results. Eighteen studies (920 patients) were included. Pre- and post-nasal EPAP means ± standard deviations (M ± SD) for apnea-hypopnea index (AHI) in 345 patients decreased from 27.32 ± 22.24 to 12.78 ± 16.89 events/hr (relative reduction = 53.2%). Random effects modeling mean difference (MD) was −14.78 events/hr [95% CI −19.12, −10.45], p value < 0.00001. Oxygen desaturation index (ODI) in 247 patients decreased from 21.2 ± 19.3 to 12.4 ± 14.1 events/hr (relative reduction = 41.5%, p value < 0.00001). Lowest oxygen saturation (LSAT) M ± SD improved in 146 patients from 83.2 ± 6.8% to 86.2 ± 11.1%, MD 3 oxygen saturation points [95% CI 0.57, 5.63]. Epworth Sleepiness Scale (ESS) M ± SD improved (359 patients) from 9.9 ± 5.3 to 7.4 ± 5.0, MD −2.5 [95% CI −3.2, −1.8], p value < 0.0001. Conclusion. Nasal EPAP (Provent) reduced AHI by 53.2%, ODI by 41.5% and improved LSAT by 3 oxygen saturation points. Generally, there were no clear characteristics (demographic factors, medical history, and/or physical exam finding) that predicted favorable response to these devices. However, limited evidence suggests that high nasal resistance could be associated with treatment failure. Additional studies are needed to identify demographic and polysomnographic characteristics that would predict therapeutic success with nasal EPAP (Provent). PMID:26798519

  18. Nasal nitric oxide and regulation of human pulmonary blood flow in the upright position.

    PubMed

    Sánchez Crespo, Alejandro; Hallberg, Jenny; Lundberg, Jon O; Lindahl, Sten G E; Jacobsson, Hans; Weitzberg, Eddie; Nyrén, Sven

    2010-01-01

    There are a number of evidences suggesting that lung perfusion distribution is under active regulation and determined by several factors in addition to gravity. In this work, we hypothesised that autoinhalation of nitric oxide (NO), produced in the human nasal airways, may be one important factor regulating human lung perfusion distribution in the upright position. In 15 healthy volunteers, we used single-photon emission computed tomography technique and two tracers (99mTc and 113mIn) labeled with human macroaggregated albumin to assess pulmonary blood flow distribution. In the sitting upright position, subjects first breathed NO free air through the mouth followed by the administration of the first tracer. Subjects then switched to either nasal breathing or oral breathing with the addition of exogenous NO-enriched air followed by the administration of the second tracer. Compared with oral breathing, nasal breathing induced a blood flow redistribution of approximately 4% of the total perfusion in the caudal to cranial and dorsal to ventral directions. For low perfused lung regions like the apical region, this represents a net increase of 24% in blood flow. Similar effects were obtained with the addition of exogenous NO during oral breathing, indicating that NO and not the breathing condition was responsible for the blood flow redistribution. In conclusion, these results provide evidence that autoinhalation of endogenous NO from the nasal airways may ameliorate the influence of gravity on pulmonary blood flow distribution in the upright position. The presence of nasal NO only in humans and higher primates suggest that it may be an important part of the adaptation to bipedalism.

  19. [Continuous positive airways pressure treatment for obstructive sleep apnoea].

    PubMed

    Antone, E; Gilbert, M; Bironneau, V; Meurice, J C

    2015-04-01

    Continuous positive airway pressure (CPAP) still remains the most frequently used and the most efficient treatment for obstructive sleep apnea syndrome. However, its efficiency is conditioned by healthcare quality depending on many factors such as medical specificities of the patients as well as the severity of sleep-related breathing disorders. In order to optimize CPAP efficiency, it is necessary to be aware of the functional abilities of the different devices, and to perform a close monitoring of the patients, particularly during the first weeks of treatment, by maximally using the data provided by the CPAP apparatus. Some questions remain unsolved, such as the impact of nasal CPAP on glucose metabolism or cardiovascular prognosis. Furthermore, the strategy of CPAP use should be improved according to future results of studies dedicated to the interest of home telemonitoring and taking into account the validated mode of CPAP initiation. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  20. Positive Behavior Support: Sustainability and Continuous Regeneration

    ERIC Educational Resources Information Center

    McIntosh, Kent; Turri, Mary G.

    2014-01-01

    Because of its widespread adoption and implementation (in over 13,000 schools in the US; Center on Positive Behavioral Interventions and Supports, 2010), there has been increasing attention to how School-wide Positive Behavior Support (SWPBS) systems can be sustained. Sustained implementation can be defined as "continued use of an…

  1. Repercussions of Surgically Assisted Maxillary Expansion on Nose Width and Position of Septum and Inferior Nasal Conchae

    PubMed Central

    Landim, Fabrício Souza; Freitas, George Borba; Malouf, Andreana Braga; Studart, Liana P. Carvalho; Rocha, Nelson Studart; de Souza Andrade, Emanuel Sávio; Caubi, Antônio Figueiredo; Filho, José Rodrigues Laureano; Oliveira e Silva, Emanuel Dias

    2011-01-01

    The aim of the present study was to assess the clinical and radiographic repercussions of surgically assisted maxillary expansion on the septum, nasal cavity and nasal conchae. The sample was made up of 15 patients with skeletal maturity (9 females and 6 males between 16 and 45 years of age) and maxillary transverse deficiency. Assessments were performed through anterior rhinoscopy and frontal cephalometric radiographs on three occasions: (T0) preoperative period, (T1) locking of the expander and (T2) six months following the locking procedure. An increase was observed in the basal portion of the pyriform aperture and distances between the lateral wall of the basal portion of the pyriform aperture and the septum. The radiographic exam revealed that the nasal septum did not undergo any statistically significant change in its position. Moreover, no significant changes in the position of the nasal septum or nasal conchae were detected throughout the three evaluation times. The results suggest that surgically assisted maxillary expansion is capable of widening the basal portion of the pyriform aperture, with little repercussion on the anterior position of the nasal septum and inferior nasal conchae. PMID:22135612

  2. Nasal temperatures in dairy cows are influenced by positive emotional state.

    PubMed

    Proctor, Helen S; Carder, Gemma

    2015-01-01

    Understanding how animals express positive emotions is an important area of focus for animal welfare science, yet it is widely neglected. Emotions can be either positive or negative in valence, depending on the rewarding or punishing nature of the stimulus, and they can vary in the degree of arousal or excitement. Previous literature has shown a strong connection between peripheral temperatures and high arousal, negative experiences. Stress, fear and frustration have all been found to cause a drop in peripheral temperature. Little is known however, about whether the experience of positive emotions affects peripheral temperatures. In this study we sought to identify whether the nasal temperature of cows was affected by emotions, and if nasal temperature could be reliably used as a measure of emotional state in cows. We induced a positive, low arousal emotional state by stroking cows in preferred regions, in a similar manner to allogrooming. We performed 350 full focal observations, each comprising three conditions; pre-stroking, stroking, and post-stroking. During each 15minute focal observation we remotely took the focal cow's nasal temperature six times, twice during each condition. We analysed the data using the one-way ANOVA repeated measures test and found a significant difference overall (F (2, 1.935)=9.372, p<0.01). Post-hoc pairwise comparisons indicated that the total mean nasal temperature decreased significantly during the stroking condition (25.91°C, SD=1.21), compared with both the pre-stroking (26.27°C, SD=1.01, p<0.01) and post-stroking conditions (26.44°C, SD=1.12, p<0.01). There was no significant difference between the pre-stroking and post-stroking conditions (p=0.14). We suggest that the cows were in a low state of arousal during the entire focal observation, as no other changes to the cows' environment had been made, and the cows were habituated to both the procedure and the researchers. Furthermore, the stroking stimulus is known to induce a

  3. Use of Biphasic Continuous Positive Airway Pressure in Premature Infant with Cleft Lip–Cleft Palate

    PubMed Central

    George, Lovya; Jain, Sunil K.

    2015-01-01

    Preterm infants (PIs) often require respiratory support due to surfactant deficiency. Early weaning from mechanical ventilation to noninvasive respiratory support decreases ventilation-associated irreversible lung damage. This wean is particularly challenging in PIs with cleft lip and cleft palate due to anatomical difficulties encountered in maintaining an adequate seal for positive pressure ventilation. PI with a cleft lip and palate often fail noninvasive respiratory support and require continued intubation and mechanical ventilation. We are presenting the first case report of a PI with cleft lip and palate who was managed by biphasic nasal continuous positive airway pressure. PMID:26495158

  4. Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients

    PubMed Central

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    Rationale In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. Objective To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Methods Newly CPAP treated OSA participating in “Observatoire Sommeil de la Fédération de Pneumologie”, a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. Results 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. Conclusion As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed. PMID:23691209

  5. Traumatic keratoplasty rupture resulting from continuous positive airway pressure mask.

    PubMed

    Fiorentzis, Miltiadis; Seitz, Berthold; Viestenz, Arne

    2015-06-01

    To report a rare case of traumatic wound dehiscence caused by the use of a continuous positive airway pressure (CPAP) mask in a patient with chronic obstructive pulmonary disease (COPD) after penetrating keratoplasty (PKP). Observational case report. A 55-year-old man who was treated with uncomplicated PKP due to pellucid marginal corneal degeneration in the right eye 9 months earlier presented to the emergency department after a globe rupture caused by dislocation of his CPAP mask during sleep. The best-corrected visual acuity (BCVA) was light perception in the right eye. The corneal graft was dehisced from 12 over 3 to 6 o'clock (180 degrees) with interruption of the double running corneal sutures and nasal iris as well as vitreous incarceration. The graft was resutured in place with 33 interrupted 10-0 monofilament nylon sutures. The BCVA improved to 20/100 three months after globe reconstruction. This case underlines the necessity of education for patients undergoing keratoplasty regarding the use of protective eyewear, to avoid predictable or accidental ocular injuries and graft dehiscence or its subsequent consequences. CPAP masks should be fitted (eyeball sparing) to the margins of the orbit after PKP.

  6. Kinect based real-time position calibration for nasal endoscopic surgical navigation system

    NASA Astrophysics Data System (ADS)

    Fan, Jingfan; Yang, Jian; Chu, Yakui; Ma, Shaodong; Wang, Yongtian

    2016-03-01

    Unanticipated, reactive motion of the patient during skull based tumor resective surgery is the source of the consequence that the nasal endoscopic tracking system is compelled to be recalibrated. To accommodate the calibration process with patient's movement, this paper developed a Kinect based Real-time positional calibration method for nasal endoscopic surgical navigation system. In this method, a Kinect scanner was employed as the acquisition part of the point cloud volumetric reconstruction of the patient's head during surgery. Then, a convex hull based registration algorithm aligned the real-time image of the patient head with a model built upon the CT scans performed in the preoperative preparation to dynamically calibrate the tracking system if a movement was detected. Experimental results confirmed the robustness of the proposed method, presenting a total tracking error within 1 mm under the circumstance of relatively violent motions. These results point out the tracking accuracy can be retained stably and the potential to expedite the calibration of the tracking system against strong interfering conditions, demonstrating high suitability for a wide range of surgical applications.

  7. When continuous positive airway pressure (CPAP) fails

    PubMed Central

    Virk, Jagdeep S.

    2016-01-01

    Obstructive sleep apnoea (OSA) is increasingly prevalent, particularly in the context of the obesity epidemic, and is associated with a significant social, health and economic impact. The gold standard of treatment for moderate to severe OSA is continuous positive airway pressure (CPAP). However compliance rates can be low. Methodology to improve patient tolerance to CPAP alongside with alternative, non-surgical and surgical, management strategies are discussed. All patients that fail CPAP therapy would benefit from formal upper airway evaluation by the otolaryngologist to identify any obvious causes and consider site-specific surgical therapies. Patient selection is integral to ensuring successful outcomes. A multidisciplinary team is needed to manage these patients. PMID:27867577

  8. Treatment of Obstructive Sleep Apnea Syndrome with Nasal Positive Airway Pressure Improves Golf Performance

    PubMed Central

    Benton, Marc L.; Friedman, Neil S.

    2013-01-01

    Study Objectives: Obstructive sleep apnea syndrome (OSAS) is associated with impairment of cognitive function, and improvement is often noted with treatment. Golf is a sport that requires a range of cognitive skills. We evaluated the impact of nasal positive airway pressure (PAP) therapy on the handicap index (HI) of golfers with OSAS. Methods: Golfers underwent a nocturnal polysomnogram (NPSG) to determine whether they had significant OSAS (respiratory disturbance index > 15). Twelve subjects with a positive NPSG were treated with PAP. HI, an Epworth Sleepiness Scale (ESS), and sleep questionnaire (SQ) were submitted upon study entry. After 20 rounds of golf on PAP treatment, the HI was recalculated, and the questionnaires were repeated. A matched control group composed of non-OSAS subjects was studied to assess the impact of the study construct on HI, ESS, and SQ. Statistical comparisons between pre- and post-PAP treatment were calculated. Results: The control subjects demonstrated no significant change in HI, ESS, or SQ during this study, while the OSAS group demonstrated a significant drop in average HI (11.3%, p = 0.01), ESS, (p = 0.01), and SQ (p = 0.003). Among the more skilled golfers (defined as HI ≤ 12), the average HI dropped by an even greater degree (31.5%). Average utilization of PAP was 91.4% based on data card reporting. Conclusions: Treatment of OSAS with PAP enhanced performance in golfers with this condition. Treatment adherence was unusually high in this study. Non-medical performance improvement may be a strong motivator for selected subjects with OSAS to seek treatment and maximize adherence. Commentary: A commentary on this article appears in this issue on page 1243. Citation: Benton ML; Friedman NS. Treatment of obstructive sleep apnea syndrome with nasal positive airway pressure improves golf performance. J Clin Sleep Med 2013;9(12):1237-1242. PMID:24340283

  9. [Long-term effects of home mechanical ventilation with positive pressure using a nasal mask].

    PubMed

    Escarrabill, J; Estopà, R; Robert, D; Casolivé, V; Manresa, F

    1991-10-05

    Home mechanical ventilation (HMV) is an efficient alternative in the treatment of patients with chronic respiratory failure secondary to restrictive mechanical disorders (neuromuscular disease, such as Duchenne's disease, thorax deformities due to kyphoscoliosis or tuberculosis sequelae). The case of a patient with severe kyphoscoliosis in the phase of chronic respiratory failure (PaO2 34 mmHg and PaCO2 61 mmHg, breathing ambient air) is presented in which, following the failure of negative pressure mechanical ventilation ("poncho"), positive pressure ventilation was tested with a silicon made-to-measure nasal mask as the access via. Adaptation to HMV was good with the patient using the ventilation nightly. Following 12 months of treatment the patient is able to carry out everyday activities and arterial gasometry breathing ambient air is PaO2 77 mmHg and PaCO2 43 mmHg.

  10. [Phrenic nerve paralysis of obstetrical origin: favorable course using continuous positive airway pressure].

    PubMed

    Escande, B; Cerveau, C; Kuhn, P; Astruc, D; Daemgen, F; Messer, J

    2000-09-01

    Isolated diaphragmatic paralysis due to obstetrical factors is rare and therapeutic management modalities are not quite clear. A neonate born by breech delivery presented with respiratory distress due to isolated paralysis of the right hemidiaphragm. The clinical course was progressive, his condition worsening with oxygen supplementation. Continuous positive airway pressure (CPAP) delivered via a nasal cannula was started in the one-month-old child, inducing gradual improvement towards recovery at the age of two months and a half. Non-invasive nasal CPAP should be proposed for the treatment of phrenic nerve obstetrical palsy before introducing more invasive ventilation techniques. Surgical plication should be delayed until the child reaches the age of at least three months.

  11. Nasal Anatomy

    MedlinePlus

    ... Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure Statement CONDITIONS Adult ... Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure Statement Printer Friendly ...

  12. Key nasal symptoms predicting a positive skin test in allergic rhinitis and patient characteristics according to ARIA classification.

    PubMed

    Chaiyasate, Saisawat; Roongrotwattanasiri, Kannika; Fooanant, Supranee; Sumitsawan, Yupa

    2009-03-01

    To find predicting symptom(s) in patients with a positive skin test, and identify patient characteristics according to ARIA classification. Four hundred and thirty four rhinologic patients were retrospectively studied. Nasal obstruction, rhinorrhea, itching, sneezing, and smell dysfunction were assessed. Patients were also classified according to the ARIA guideline. Of 434 patients, 277 (63.8%) were skin prick test positive. There was no statistical difference in sex, but the mean age of the positive skin test group was lower than that in the negative group (p < 0.05). Intermittent or persistent symptoms and total symptom score were not significantly different. Severe nasal itching was more common in the positive group (p = 0.04). The impact of symptoms was similar between the two groups, except for self-reported comorbidity, which was higher in the negative group (p = 0.039). There were no predicting symptoms and no difference in the symptom characteristics for the patients with positive skin test.

  13. Change in upper airway geometry between upright and supine position during tidal nasal breathing.

    PubMed

    Van Holsbeke, Cedric S; Verhulst, Stijn L; Vos, Wim G; De Backer, Jan W; Vinchurkar, Samir C; Verdonck, Pascal R; van Doorn, Johanna W D; Nadjmi, Nasser; De Backer, Wilfried A

    2014-02-01

    As the upper airway is the most important limiting factor for the deposition of inhalation medication in the lower airways, it is interesting to assess how its morphology varies between different postures. The goal of this study is to compare the upper airway morphology and functionality of healthy volunteers in the upright and supine positions during tidal nasal breathing and to search for baseline indicators for these changes. This is done by performing three-dimensional measurements on computed tomography (CT) and cone beam computed tomography (CBCT) scans. This prospective study was approved by all relevant institutional review boards. All patients gave their signed informed consent. In this study, 20 healthy volunteers (mean age, 62 years; age range, 37-78 years; mean body mass index, 29.26; body mass index range, 21.63-42.17; 16 men, 4 women) underwent a supine low-dose CT scan and an upright CBCT scan of the upper airway. The (local) average (Savg) and minimal (Smin) cross-sectional area, the position of the latter, the concavity, and the airway resistance were examined to determine if they changed from the upright to the supine position. If changes were found, baseline parameters were sought that were indicators for these differences. There were five dropouts due to movement artifacts in the CBCT scans. Savg and Smin were 9.76% and 26.90% larger, respectively, in the CBCT scan than in the CT scan, whereas the resistance decreased by 26.15% in the upright position. The Savg of the region between the hard palate and the bottom of the uvula increased the most (49.85%). In people with a high body mass index, this value changed the least. The airway resistance in men decreased more than in women. This study demonstrated that there are differences in upper airway morphology and functionality between the supine and upright positions and that there are baseline indicators for these differences.

  14. Role of nasal positive end expiratory pressure valve as an alternative treatment for obstructive sleep apnoea in Chinese patients.

    PubMed

    To, Kin Wang; Chan, Tat O; Ng, Susana; Ngai, Jenny; Hui, David Sc

    2016-04-01

    As compliance of continuous positive airway pressure (CPAP) for treatment of obstructive sleep apnoea (OSA) is often suboptimal, a less cumbersome treatment is desirable. We explored the clinical usefulness of nasal positive end expiratory pressure (nPEEP) valves. Symptomatic OSA patients (apnoea hypopnea index (AHI) >5/h by polysomnography (PSG) or >10/h by type III devices), who declined CPAP, were recruited. A nPEEP valve was attached to each nostril before bed. After successful acclimatization for 1 week, treatment was continued for 4 weeks. The nPEEP valves provided expiratory resistance to build up PEEP. PSG was performed at week 4. Among 196 subjects, 46 (23%) failed acclimatization and 14 (7%) withdrew. Among the 120 patients with a valid PSG, 72 (60%) and 75 (63%) had >50% reduction in mean (standard deviation) overall AHI 26 (16)/h to 18 (18)/h and mean supine AHI 31 (19)/h to 11(16)/h, respectively, P < 0.001. Compared with responders, patients with <50% reduction in AHI had a higher mean overall AHI (30/h vs 23/h, P = 0.03), higher mean supine AHI (35/h vs 26/h, P = 0.04), more severe mean oxygen desaturation nadir (76.7% vs 82.7%, P < 0.01) and longer mean period of desaturation <90% SaO2 (7.7 vs 2.4, P = 0.02). Breathing discomfort and dry mouth were the most common side effects. Compared with a dental device, there was a larger mean reduction in supine AHI using nPEEP (29 (14)/h vs 16 (17)/h). nPEEP valves were useful in selected patients with mild or positional-related OSA. © 2015 Asian Pacific Society of Respirology.

  15. Bubble continuous positive airway pressure in a human immunodeficiency virus-infected infant

    PubMed Central

    McCollum, E. D.; Smith, A.; Golitko, C. L.

    2014-01-01

    SUMMARY World Health Organization-classified very severe pneumonia due to Pneumocystis jirovecii infection is recognized as a life-threatening condition in human immunodeficiency virus (HIV) infected infants. We recount the use of nasal bubble continuous positive airway pressure (BCPAP) in an HIV-infected African infant with very severe pneumonia and treatment failure due to suspected infection with P. jirovecii. We also examine the potential implications of BCPAP use in resource-poor settings with a high case index of acute respiratory failure due to HIV-related pneumonia, but limited access to mechanical ventilation. PMID:21396221

  16. Effects of non-synchronised nasal intermittent positive pressure ventilation on spontaneous breathing in preterm infants.

    PubMed

    Owen, L S; Morley, C J; Dawson, J A; Davis, P G

    2011-11-01

    Nasal intermittent positive pressure ventilation (NIPPV) may be beneficial but the mechanisms of action are undetermined. To investigate the effects of non-synchronised NIPPV on spontaneous breathing in premature infants. 10 infants receiving ventilator generated non-synchronised NIPPV were studied for 30 min. Delivered pressure was measured at the nose; respiration was recorded using respiratory inductance plethysmography. Oxygen saturation, carbon dioxide, heart rate, inspired oxygen and video images were recorded. Median gestational age, birth weight, age and study weight were 25(+3) weeks, 797 g, 24 days and 1076 g. When the NIPPV pressure peak commenced during spontaneous inspiration the inspiratory time increased by 21% (p=0.002), relative tidal volume increased by 15% (p=0.01) and expiratory time was unchanged. When the NIPPV pressure peak commenced during spontaneous expiration the expiratory time increased by 13% (p=0.04). NIPPV pressures delivered during apnoea (range 8-28 cm H(2)O) produced chest inflation 5% of the time, resulting in small tidal volumes (26.7% of spontaneous breath size) but reduced oxygen desaturation. NIPPV pressure peaks occurred throughout spontaneous respiration proportional to the inspiratory: expiratory ratio. NIPPV pressure peaks only resulted in a small increase in relative tidal volumes when delivered during spontaneous inspiration. During apnoea pressure peaks occasionally resulted in chest inflation, which ameliorated oxygen desaturations. Infants did not become entrained with the NIPPV pressure changes. Synchronising every rise in applied pressure with spontaneous inspiration may increase the effectiveness of NIPPV and warrants investigation.

  17. Use of nasal intermittent positive pressure ventilation to avoid intubation in neonates.

    PubMed

    Manzar, Shabih; Nair, Arun K; Pai, Mangalore G; Paul, Jose; Manikoth, Prakash; Georage, Mariam; Al-Khusaiby, Saleh M

    2004-10-01

    Nasal intermittent positive pressure ventilation (NIPPV) has widely been used in neonates to prevent extubation failure and apnea. This pilot study was carried out to look at the early use of NIPPV to avoid intubation. The study was carried out over a period of 3 months from August 2003 to October 2003 at the Royal Hospital, Muscat, Sultanate of Oman. The neonates with clinical signs of moderate to severe respiratory distress were given a trial of early NIPPV based on the avoid-intubation protocol. Inclusion, exclusion and failure criteria with general procedure were made clear to all medical and nursing staff and the protocol was posted in the unit for further time to time referral. A total of 16 neonates met the inclusion criteria for early NIPPV trial. Out of these, 13 (81%) had a successful NIPPV. The mean age of entry was 0.95 hours; however, the mean duration of NIPPV was 23 hours. No NIPPV related complications were noted in the study group. We concluded that NIPPV is an appropriate mode of ventilation in neonates requiring respiratory support. The major advantage of NIPPV is the non-invasive mechanics. It is also less expensive and less labor intensive. Further randomized controlled trials with larger sample size are warranted to confirm our findings.

  18. High Altitude, Continuous Positive Airway Pressure, and Obstructive Sleep Apnea: Subjective Observations and Objective Data

    PubMed Central

    Malhotra, Atul; Schwartz, Eli

    2013-01-01

    Abstract Ginosar, Yehuda, Atul Malhotra, and Eli Schwartz. High altitude, continuous positive airway pressure, and obstructive sleep apnea: Subjective observations and objective data. High Alt Med Biol 14:186–189, 2013.—We report observations made by one of the authors who ascended to the Thorang La pass (5416 m) in the Nepal Himalaya in October 2010, despite moderate-severe obstructive sleep apnea. We report the first recorded use of nasal CPAP to treat high altitude pulmonary edema (progressively severe dyspnea at rest and severe orthopnea, with tachycardia and tachypnea) that occurred at 4400 meters, when snow and darkness made safe evacuation difficult. We also present objective longitudinal data of the effects of altitude on auto-adjusting CPAP delivered via a portable nasal CPAP device, and on the apnea hypopnea index measured during sleep while using the device. OSA may be a risk factor for the development of high altitude pulmonary edema and we suggest that a nasal CPAP device located in high altitude trekking stations may provide an additional or alternative treatment option for managing high altitude pulmonary edema until evacuation is possible. PMID:23795742

  19. Rhinoplasty Setsquare Device: A Novel Instrument to Verify Columellar and Nasal Dorsal Position at the Midsagittal Line.

    PubMed

    Çerçi Özkan, Aret

    2017-07-01

    Even a mild degree of postoperative deviation of the nasal dorsum and/or columella from the midsagittal plane could be enough to displease a patient. Postoperative judgment of the nasal dorsum and the columellar positioning on the midsagittal plane is somewhat of a subjective decision determined by the surgeons' naked eye. Most innovations tend to evolve from necessities. The risk and reality of misjudging the positioning for both the nasal dorsum and/or the columella led me to develop a device for the objective measurement of the midsagittal axis of the nose. I have called it the rhinoplasty setsquare device. This device is made from 316 quality stainless chrome. It is completely sterilizable. It consists of 4 main parts. During the finishing touches of the operation, the correct placement of the rhinoplasty setsquare device will provide the surgeon with an objective decision that will help make the positioning of the nasal dorsum and the columella more precise. When I conducted my research on literature and device catalogs for possible devices designed for measurement in rhinoplasty operations, I ran into devices such as the Castroviejo caliper, calibrated lateral crus stabilizer, Joseph measuring rod, and Thorpe Marchac caliper. All of them are unique in their function and design. However, as far as I could see, there is no device similar in form and function to my rhinoplasty setsquare device. I have been using this device for 8 months for all my rhinoplasty patients. I am more confident now in my postoperative results due to its objective measurement of the midsagittal line.

  20. [The effectiveness of measurement of nasal resistance in patients with sleep disordered breathing].

    PubMed

    Shimoyama, Kumiko; Yasuda, Kyo; Kawano, Masako; Satoh, Makoto

    2009-06-01

    Nasal breathing disorder has been associated with the condition and treatment of sleep disordered breathing (SDB). In the current study, we investigated the utility of measurement of nasal resistance in patients with SDB. We examined the relationship between nasal symptoms and nasal resistance in 219 patients, and how the results affected the administration of nasal continuous positive airway pressure (nCPAP) in 34 SDB patients. Total nasal resistance was not significantly different between patients who were divided into two groups: those with nasal symptoms, and those without. The left-right ratio of nasal flow in the group with nasal symptoms was higher than in the group without nasal symptoms (p < 0.01). The mean percentage of nCPAP use was not significantly different between two groups divided by total nasal resistance. The mean percentage of nCPAP use > or = 4 hours was lower in the group in which total nasal resistance was more than 0.25Pa/cm3/sec (p < 0.05). The left-right ratio of nasal flow does not affect nCPAP use. We conclude that measurement of nasal resistance for confirming nasal breathing disorder is effective in patients with SDB, whether a patient complains of nasal symptoms or not.

  1. Dynamic Changes in Heart Rate Variability and Nasal Airflow Resistance during Nasal Allergen Provocation Test.

    PubMed

    Seppänen, Tiina M; Alho, Olli-Pekka; Seppänen, Tapio

    2016-01-01

    Allergic rhinitis is a major chronic respiratory disease and an immunoneuronal disorder. We aimed at providing further knowledge on the function of the neural system in nasal allergic reaction. Here, a method to assess simultaneously the nasal airflow resistance and the underlying function of autonomic nervous system (ANS) is presented and used during the nasal provocation of allergic and nonallergic subjects. Continuous nasal airflow resistance and spectral heart rate variability parameters show in detail the timing and intensity differences in subjects' reactions. After the provocation, the nasal airflow resistance of allergic subjects showed a positive trend, whereas LF/HF (Low Frequency/High Frequency) ratio and LF power showed a negative trend. This could imply a gradual sympathetic withdrawal in allergic subjects after the allergen provocation. The groups differed significantly by these physiological descriptors. The proposed method opens entirely new opportunities to research accurately concomitant changes in nasal breathing function and ANS.

  2. Dynamic Changes in Heart Rate Variability and Nasal Airflow Resistance during Nasal Allergen Provocation Test

    PubMed Central

    Seppänen, Tiina M.; Alho, Olli-Pekka; Seppänen, Tapio

    2016-01-01

    Allergic rhinitis is a major chronic respiratory disease and an immunoneuronal disorder. We aimed at providing further knowledge on the function of the neural system in nasal allergic reaction. Here, a method to assess simultaneously the nasal airflow resistance and the underlying function of autonomic nervous system (ANS) is presented and used during the nasal provocation of allergic and nonallergic subjects. Continuous nasal airflow resistance and spectral heart rate variability parameters show in detail the timing and intensity differences in subjects' reactions. After the provocation, the nasal airflow resistance of allergic subjects showed a positive trend, whereas LF/HF (Low Frequency/High Frequency) ratio and LF power showed a negative trend. This could imply a gradual sympathetic withdrawal in allergic subjects after the allergen provocation. The groups differed significantly by these physiological descriptors. The proposed method opens entirely new opportunities to research accurately concomitant changes in nasal breathing function and ANS. PMID:27196870

  3. Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas.

    PubMed

    Chen, John Z; Katz, Ira M; Pichelin, Marine; Zhu, Kaixian; Caillibotte, Georges; Noga, Michelle L; Finlay, Warren H; Martin, Andrew R

    2017-01-01

    Portable oxygen concentrators (POCs) typically include pulse flow (PF) modes to conserve oxygen. The primary aims of this study were to develop a predictive in vitro model for inhaled oxygen delivery using a set of realistic airway replicas, and to compare PF for a commercial POC with steady flow (SF) from a compressed oxygen cylinder. Experiments were carried out using a stationary compressed oxygen cylinder, a POC, and 15 adult nasal airway replicas based on airway geometries derived from medical images. Oxygen delivery via nasal cannula was tested at PF settings of 2.0 and 6.0, and SF rates of 2.0 and 6.0 L/min. A test lung simulated three breathing patterns representative of a chronic obstructive pulmonary disease patient at rest, during exercise, and while asleep. Volume-averaged fraction of inhaled oxygen (FiO2) was calculated by analyzing oxygen concentrations sampled at the exit of each replica and inhalation flow rates over time. POC pulse volumes were also measured using a commercial O2 conserver test system to attempt to predict FiO2 for PF. Relative volume-averaged FiO2 using PF ranged from 68% to 94% of SF values, increasing with breathing frequency and tidal volume. Three of 15 replicas failed to trigger the POC when used with the sleep breathing pattern at the 2.0 setting, and four of 15 replicas failed to trigger at the 6.0 setting. FiO2 values estimated from POC pulse characteristics followed similar trends but were lower than those derived from airway replica experiments. For the POC tested, PF delivered similar, though consistently lower, volume-averaged FiO2 than SF rates equivalent to nominal PF settings. Assessment of PF oxygen delivery using POC pulse characteristics alone may be insufficient; testing using airway replicas is useful in identifying possible cases of failure and may provide a better assessment of FiO2.

  4. Nasal polyps

    MedlinePlus

    ... get rid of nasal polyps. Nasal steroid sprays shrink polyps. They help clear blocked nasal passages and ... is stopped. Corticosteroid pills or liquid may also shrink polyps, and can reduce swelling and nasal congestion. ...

  5. Continuous positive airway pressure (CPAP) for acute bronchiolitis in children.

    PubMed

    Jat, Kana R; Mathew, Joseph L

    2015-01-07

    Acute bronchiolitis is one of the most frequent causes of emergency department visits and hospitalisation in infants. There is no specific treatment for bronchiolitis except for supportive therapy. Continuous positive airway pressure (CPAP) is supposed to widen the peripheral airways of the lung, allowing deflation of over-distended lungs in bronchiolitis. The increase in airway pressure also prevents the collapse of poorly supported peripheral small airways during expiration. In observational studies, CPAP is found to be beneficial in acute bronchiolitis. To assess the efficacy and safety of CPAP compared to no CPAP or sham CPAP in infants and children up to three years of age with acute bronchiolitis. We searched CENTRAL (2014, Issue 3), MEDLINE (1946 to April week 2, 2014), EMBASE (1974 to April 2014), CINAHL (1981 to April 2014) and LILACS (1982 to April 2014). We considered randomised controlled trials (RCTs), quasi-RCTS, cross-over RCTs and cluster-RCTs evaluating the effect of CPAP in children with acute bronchiolitis. Two review authors independently assessed study eligibility, extracted data using a structured proforma, analysed the data and performed meta-analyses. We included two studies with a total of 50 participants under 12 months of age. In one study there was a high risk of bias for incomplete outcome data and selective reporting, and both studies had an unclear risk of bias for several domains including random sequence generation. The effect of CPAP on the need for mechanical ventilation in children with acute bronchiolitis was uncertain due to imprecision around the effect estimate (two RCTs, 50 participants; risk ratio (RR) 0.19, 95% CI 0.01 to 3.63; low quality evidence). Neither trial measured our other primary outcome of time to recovery. One trial found that CPAP significantly improved respiratory rate compared with no CPAP (one RCT, 19 participants; mean difference (MD) -5.70 breaths per minute, 95% CI -9.30 to -2.10), although the other

  6. The effect of head position on the distribution of topical nasal medication using the Mucosal Atomization Device: a cadaver study.

    PubMed

    Habib, Al-Rahim R; Thamboo, Andrew; Manji, Jamil; Dar Santos, Rachelle C; Gan, Eng Cern; Anstead, Amy; Javer, Amin R

    2013-12-01

    The Mucosal Atomization Device (MAD) distributes medication throughout the paranasal sinuses for patients with chronic rhinosinusitis (CRS). Determining the optimal head position is important to ensure maximal delivery of medication to the sinus cavities. The objective of this work was to determine the effect of the lying-head-back (LHB) and head-down and forward (HDF) position, on the distribution of topical nasal medication via MAD in cadaver specimens. Twenty specimens having received complete functional endoscopic sinus dissection were chosen. The MAD was used to administer 2 mL of fluorescein-impregnated saline solution through the nose in both the LHB and HDF positions. Fluorescein was identified on 11 predetermined anatomical areas using a blue light filter. Three blinded investigators assessed endoscopic images to determine the presence of fluorescein. A total of 440 anatomical locations (n = 20 cadavers) received administration of the fluorescein nasal spray in the LHB or HDF position. LHB position had significantly greater total distribution to all pertinent anatomical sites than the HDF position (76% vs 41%; p < 0.001; 95% confidence interval [CI], 0.26-0.44). The proportion of staining was significantly greater for the ethmoid (p = 0.11; 95% CI, 0.05-0.66), frontal (p < 0.01; 95% CI, 0.20-0.80), and sphenoid sinuses (p = 0.03; 95% CI, 0.07-0.73) when compared to the HDF position. A greater distribution of medication to the sinonasal cavities was observed in the LHB position compared to the HDF position. These areas are of particular clinical relevance in postsurgical patients with refractory CRS. © 2013 ARS-AAOA, LLC.

  7. Randomized trial of continuous positive airways pressure to prevent reventilation in preterm infants.

    PubMed

    Peake, M; Dillon, P; Shaw, N J

    2005-03-01

    A prospective randomized controlled trial was performed comparing the use of a short period (24 hr) of postextubation nasal continuous positive airways pressure (CPAP) with direct extubation into headbox oxygen on the outcome of the need for reintubation within 7 days of initial extubation. Infants at less than 32 weeks of gestation who had received mechanical ventilation in the first 28 postnatal days and were being extubated for the first time were recruited. Ninety-seven babies were entered into the study (48 CPAP and 49 headbox oxygen). Twenty-four (49%) babies in the headbox group were reventilated within a week, compared to 16 (33%) in the CPAP group (P=0.17). By 14 days after initial extubation, 25 babies (51%) in the headbox group and 23 (48%) in the CPAP group required reventilation (P=0.9). There was a trend toward babies in the CPAP group requiring fewer reintubations (median, 2; range, 1-6) compared to those in the headbox group (median, 3; range, 1-7) (P=0.063). There was no significant difference between groups with respect to total number of days of ventilation (headbox median, 4; range, 1-24; CPAP median, 2; range, 1-20). In conclusion, this study showed that a short period of nasal CPAP is not associated with a reduction in reventilation.

  8. Obstructive sleep apnea: a comparison of continuous positive airway pressure and surgical treatment.

    PubMed

    Anand, V K; Ferguson, P W; Schoen, L S

    1991-09-01

    Since earlier descriptions of the syndrome of obstructive sleep apnea (OSA), various treatment alternatives have included a variety of medical regimens, continuous positive airway pressure (CPAP), tracheostomy, and other surgical options. A lack of acceptable criteria for surgical intervention remains an important concern for the surgeon. in an attempt to resolve some of the controversies pertaining to various therapeutic modalities, we performed a retrospective analysis--from 1983 to the present--of posttreatment results in patients who underwent surgical therapy and those who were treated primarily with CPAP at this institution. Of 400 patients diagnosed with OSA, only 66 underwent surgical treatment, including uvulopalatopharyngoplasty. CPAP was the mainstay of treatment in the majority of our patients. Post-treatment data were available for 50 patients treated with CPAP and for 45 patients treated surgically. A comparative analysis of polysomnographic studies revealed superior cures with CPAP, although long-term compliance remains a significant problem. We advocate CPAP as initial therapy in patients with no clinically apparent causes for obstruction (e.g., nasal polyps, deviated nasal septum, or obstructive tonsillar hypertrophy) because of the predictability of success, and lower costs and complication rates. Long-term followup of OSA patients is indicated, regardless of treatment modality.

  9. The continuity of the output entropy of positive maps

    SciTech Connect

    Shirokov, Maxim E

    2011-10-31

    Global and local continuity conditions for the output von Neumann entropy for positive maps between Banach spaces of trace-class operators in separable Hilbert spaces are obtained. Special attention is paid to completely positive maps: infinite dimensional quantum channels and operations. It is shown that as a result of some specific properties of the von Neumann entropy (as a function on the set of density operators) several results on the output entropy of positive maps can be obtained, which cannot be derived from the general properties of entropy type functions. In particular, it is proved that global continuity of the output entropy of a positive map follows from its finiteness. A characterization of positive linear maps preserving continuity of the entropy (in the following sense: continuity of the entropy on an arbitrary subset of input operators implies continuity of the output entropy on this subset) is obtained. A connection between the local continuity properties of two completely positive complementary maps is considered. Bibliography: 21 titles.

  10. A Novel Nasal Expiratory Positive Airway Pressure (EPAP) Device for the Treatment of Obstructive Sleep Apnea: A Randomized Controlled Trial

    PubMed Central

    Berry, Richard B.; Kryger, Meir H.; Massie, Clifford A.

    2011-01-01

    Study Objectives: Investigate the efficacy of a novel nasal expiratory positive airway pressure (EPAP) device as a treatment for obstructive sleep apnea (OSA). Design: A prospective, multicenter, sham-controlled, parallel-group, randomized, double-blind clinical trial. Setting: 19 sites including both academic and private sleep disorder centers Patients: Obstructive sleep apnea with a pre-study AHI ≥ 10/hour Interventions: Treatment with a nasal EPAP device (N = 127) or similar appearing sham device (N = 123) for 3 months. Polysomnography (PSG) was performed on 2 non-consecutive nights (random order: device-on, device-off) at week 1 and after 3 months of treatment. Analysis of an intention to treat group (ITT) (patients completing week 1 PSGs) (EPAP N = 119, sham N = 110) was performed. Measurements and Results: At week 1, the median AHI value (device-on versus device-off) was significantly lower with EPAP (5.0 versus 13.8 events/h, P < 0.0001) but not sham (11.6 versus 11.1 events/h, P = NS); the decrease in the AHI (median) was greater (−52.7% vs. −7.3%, P < 0.0001) for the ITT group. At month 3, the percentage decrease in the AHI was 42.7% (EPAP) and 10.1% (sham), P < 0.0001. Over 3 months of EPAP treatment the Epworth Sleepiness Scale decreased (9.9 ± 4.7 to 7.2 ± 4.2, P < 0.0001), and the median percentage of reported nights used (entire night) was 88.2%. Conclusions: The nasal EPAP device significantly reduced the AHI and improved subjective daytime sleepiness compared to the sham treatment in patients with mild to severe OSA with excellent adherence. Clinical Trial Information: Registrations: ClinicalTrials.gov. Trial name: Randomized Study of Provent Versus Sham Device to Treat Obstructive Sleep Apnea (AERO). URL: http://www.clinicaltrials.gov/ct2/show/NCT00772044?term=Ventus&rank=1. Registration Number: NCT00772044. Citation: Berry RB; Kryger MH; Massie CA. A novel nasal expiratory positive airway pressure (EPAP) device for the treatment of

  11. The Supraglottic Effect of a Reduction in Expiratory Mask Pressure During Continuous Positive Airway Pressure

    PubMed Central

    Masdeu, Maria J.; Patel, Amit V.; Seelall, Vijay; Rapoport, David M.; Ayappa, Indu

    2012-01-01

    Study Objectives: Patients with obstructive sleep apnea may have difficulty exhaling against positive pressure, hence limiting their acceptance of continuous positive airway pressure (CPAP). C-Flex is designed to improve comfort by reducing pressure in the mask during expiration proportionally to expiratory airflow (3 settings correspond to increasing pressure changes). When patients use CPAP, nasal resistance determines how much higher supraglottic pressure is than mask pressure. We hypothesized that increased nasal resistance results in increased expiratory supraglottic pressure swings that could be mitigated by the effects of C-Flex on mask pressure. Design: Cohort study. Setting: Sleep center. Participants: Seventeen patients with obstructive sleep apnea/hypopnea syndrome and a mechanical model of the upper airway. Interventions: In patients on fixed CPAP, CPAP with different C-Flex levels was applied multiple times during the night. In the model, 2 different respiratory patterns and resistances were tested. Measurements and Results: Airflow, expiratory mask, and supraglottic pressures were measured on CPAP and on C-Flex. Swings in pressure during expiration were determined. On CPAP, higher nasal resistance produced greater expiratory pressure swings in the supraglottis in the patients and in the model, as expected. C-Flex 3 produced expiratory drops in mask pressure (range −0.03 to −2.49 cm H2O) but mitigated the expira-tory pressure rise in the supraglottis only during a sinusoidal respiratory pattern in the model. Conclusions: Expiratory changes in mask pressure induced by C-Flex did not uniformly transmit to the supraglottis in either patients with obstructive sleep apnea on CPAP or in a mechanical model of the upper airway with fixed resistance. Data suggest that the observed lack of expiratory drop in supraglottic pressure swings is related to dynamics of the C-Flex algorithm. Citation: Masdeu MJ; Patel AV; Seelall V; Rapoport DM; Ayappa I. The

  12. Graded exposure therapy for addressing claustrophobic reactions to continuous positive airway pressure: a case series report.

    PubMed

    Means, Melanie K; Edinger, Jack D

    2007-01-01

    Continuous positive airway pressure (CPAP) is a safe, effective treatment for obstructive sleep apnea, and yet many patients develop claustrophobic reactions to the CPAP nasal mask and cannot tolerate this treatment. We examined the efficacy of a graded in-vivo exposure therapy for enhancing CPAP adherence using a retrospective, case series design. Objective CPAP adherence data were obtained on clinical patients who attended 1 or more sessions of exposure therapy with a behavioral sleep psychologist. Compared to pre-treatment, patients used CPAP significantly longer after exposure therapy. No predictors of treatment response were identified. CPAP exposure therapy may be beneficial in some cases; however, further research is needed to determine types of patients most likely to benefit from this therapy.

  13. Measuring Nasal Obstruction.

    PubMed

    Keeler, Jarrod; Most, Sam P

    2016-08-01

    The nose and the nasal airway is highly complex with intricate 3-dimensional anatomy, with multiple functions in respiration and filtration of the respired air. Nasal airway obstruction (NAO) is a complex problem with no clearly defined "gold-standard" in measurement. There are 3 tools for the measurement of NAO: patient-derived measurements, physician-observed measurements, and objective measurements. We continue to work towards finding a link between subjective and objective nasal obstruction. The field of evaluation and surgical treatment for NAO has grown tremendously in the past 4-5 decades and will continue to grow as we learn more about the pathophysiology and treatment of nasal obstruction.

  14. Effect of silicon gel sheeting in nasal injury associated with nasal CPAP in preterm infants.

    PubMed

    Günlemez, Ayla; Isken, Tonguç; Gökalp, Ayse S; Türker, Gülcan; Arisoy, Engin A

    2010-03-01

    We conducted this study to investigate the efficacy of the silicon gel application on the nares in prevention of nasal injury in preterm infants ventilated with nasal continuous positive airway pressure (NCPAP). Patients (n=179) were randomized into two groups: Group 1 (n=87) had no silicon gel applied to nares, and in Group 2 (n=92), the silicon gel sheeting was used on the surface of nares during ventilation with NCPAP. Nasal injury developed in 13 (14.9%) neonates in Group 1 and 4 (4.3%) newborns in Group 2 (OR:3.43; 95% CI: 1.1-10.1; P<0.05). The incidence of columella necrosis was also significantly higher in the Group 1 (OR: 6.34; 95% CI: 0.78-51.6; P<0.05). We conclude that the silicon gel application may reduce the incidence and the severity of nasal injury in preterm infants on nasal CPAP.

  15. Intergenerational continuity in economic hardship, parental positivity, and positive parenting: The association with child behavior.

    PubMed

    Jeon, Shinyoung; Neppl, Tricia K

    2016-02-01

    The current study examined intergenerational continuity in economic hardship, parental positivity, and positive parenting across generations based on both the family stress model (FSM) and the family resilience framework. The study included 220 generation 1 (G1) parents, their target youth (generation 2: G2) who participated from adolescence through adulthood, and the target's child (generation 3: G3). Assessments included observational and self-report measures. Results indicated that G1 economic hardship negatively influenced both G1 positivity and G1 positive parenting. Similarly, G2 economic hardship was negatively related to both G2 positivity and G2 positive parenting, which in turn was associated with G3 positive behavior to G2. For both G1 and G2, parental positivity mediated the association between economic hardship and positive parenting. G2 economic hardship was indirectly related to G3 positive behavior through G2 parental positivity and positive parenting. An important finding is that the intergenerational continuity of economic hardship, positivity, and positive parenting were transmitted from G1 to G2. Results suggest that even in times of economic adversity, parental positivity and positive parenting were transmitted from G1 parents to their G2 youth during adulthood. Such continuity seems to influence the positive behavior of the G3 children.

  16. Intergenerational continuity in economic hardship, parental positivity, and positive parenting: The association with child behavior

    PubMed Central

    Jeon, Shinyoung; Neppl, Tricia K.

    2015-01-01

    The current study examined intergenerational continuity in economic hardship, parental positivity, and positive parenting across generations based on both the Family Stress Model and the Family Resilience Framework. The study included 220 generation one (G1) parents, their target youth (generation two: G2) who participated from adolescence through adulthood, and the target’s child (generation three: G3). Assessments included observational and self-report measures. Results indicated that G1 economic hardship negatively influenced both G1 positivity and G1 positive parenting. Similarly, G2 economic hardship was negatively related to both G2 positivity and G2 positive parenting which, in turn, was associated with G3 positive behavior to G2. For both G1 and G2, parental positivity mediated the association between economic hardship and positive parenting. G2 economic hardship was indirectly related to G3 positive behavior through G2 parental positivity and positive parenting. An important finding is that the intergenerational continuity of economic hardship, positivity, and positive parenting were transmitted from G1 to G2. Results suggest that even in times of economic adversity, parental positivity and positive parenting were transmitted from G1 parents to their G2 youth during adulthood. Such continuity seems to influence the positive behavior of the G3 children. PMID:26371448

  17. Continuously-Variable Positive-Mesh Power Transmission

    NASA Technical Reports Server (NTRS)

    Johnson, J. L.

    1982-01-01

    Proposed transmission with continuously-variable speed ratio couples two mechanical trigonometric-function generators. Transmission is expected to handle higher loads than conventional variable-pulley drives; and, unlike variable pulley, positive traction through entire drive train with no reliance on friction to transmit power. Able to vary speed continuously through zero and into reverse. Possible applications in instrumentation where drive-train slippage cannot be tolerated.

  18. Continuous Morse-Smale flows with three equilibrium positions

    NASA Astrophysics Data System (ADS)

    Zhuzhoma, E. V.; Medvedev, V. S.

    2016-05-01

    Continuous Morse-Smale flows on closed manifolds whose nonwandering set consists of three equilibrium positions are considered. Necessary and sufficient conditions for topological equivalence of such flows are obtained and the topological structure of the underlying manifolds is described. Bibliography: 36 titles.

  19. Sleep and neuromuscular disease: bilevel positive airway pressure by nasal mask as a treatment for sleep disordered breathing in patients with neuromuscular disease

    PubMed Central

    Guilleminault, C.; Philip, P.; Robinson, A.

    1998-01-01

    their masks. Three patients with myotonic dystrophy presented continued daytime somnolence despite apparent adequate treatment of their sleep disordered breathing. This required the addition of stimulant medication to their regimen. During this time three additional subjects had to be switched to nasal mask intermittent positive pressure ventilation delivered by traditional volume cycled home ventilator (volume controlled NIPPV).
CONCLUSIONS—Bilevel positive airway pressure delivered by nasal mask may be used successfully to treat sleep disordered breathing associated with neuromuscular disease. This device can be employed to assist nocturnal ventilation by either the spontaneous or timed mode. In the United States it is less expensive and easier to institute than volume controlled NIPPV and may be as efficacious as this mode if close surveillance and regular re-evaluation of the patient's status is maintained.

 PMID:9703177

  20. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    PubMed

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to < 5/h on a titration study. However, it was not previously known whether switching from one CPAP mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, p<0.001). All 14 subjects had a higher residual AHI with the oronasal versus nasal mask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of < 5/h in the laboratory. A higher residual AHI was seen in all patients with the use of an oronasal mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Continuous position measurements and the quantum Zeno effect

    NASA Astrophysics Data System (ADS)

    Gagen, M. J.; Wiseman, H. M.; Milburn, G. J.

    1993-07-01

    We present a model of continuous (in time) position measurements on a quantum system using a single pseudoclassical meter. The nonselective evolution of the system is described by a master equation which is identical to that obtained from previous models. The selective evolution is described by a stochastic nonlinear Schrödinger equation. The significance of this equation is that the stochastic term has a physical interpretaion. By carefully choosing the parameters which define the meter and the system-meter coupling, we obtain a meter pointer with well-defined position which undergoes fluctuations. This ``jitter'' in the pointer position gives rise to the stochastic dynamical collapse of the system wave function. By the inclusion of feedback on the meter, the pointer is made to relax towards an appropriate readout. We apply this model to the selective measurement of the position of a particle in a double-well potential. In contrast to a recent claim [H. Fearn and W. E. Lamb, Jr., Phys. Rev. A 46, 1199 (1992)] we show that truly continuous position measurements lead to a quantum Zeno effect in certain parameter regimes. This is manifest by the changing of the particle dynamics from coherent tunneling between the well minima to incoherent flipping, as in a random telegraph. As the measurement strength increases, the average length of time the particle remains stuck in one well increases proportionally.

  2. Continuous positive airway pressure improves sleep apnea associated fatty liver.

    PubMed

    Shpirer, Isaac; Copel, Laurian; Broide, Efrat; Elizur, Arnon

    2010-08-01

    Treatment of sleep apnea can improve liver enzyme abnormalities in patients with nonalcoholic fatty liver disease. However, the effect of continuous positive airway pressure therapy for sleep apnea on liver fat accumulation was not assessed. Liver biopsy is the "gold standard" for determining and quantifying liver fat accumulation; however, obtaining two separate liver biopsies is challenging. We examined, using a newly described computerized tomography method to quantify liver fat accumulation, whether treatment of sleep apnea improves liver steatosis. In a prospective cohort study, patients diagnosed with obstructive sleep apnea, at Assaf Harofeh Medical Center's sleep laboratory, were identified. Patients completed a questionnaire and underwent blood tests for liver enzymes and lipid profile, and computed tomography scans to determine the liver attenuation index. Patients with liver attenuation index or=30%) were treated with continuous positive airway pressure for 2-3 years. Subsequently, patients underwent repeat blood tests and tomography scans. Of 47 patients who were analyzed, 16 had a low liver attenuation index (continuous positive airway pressure treatment demonstrated significant improvement in the mean liver attenuation index, whereas noncompliant patients did not. Patients with nonalcoholic fatty-liver disease may benefit from identification and treatment for obstructive sleep apnea because treatment may improve liver steatosis.

  3. False-Positive Stress Echocardiograms: A Continuing Challenge.

    PubMed

    Qamruddin, Salima

    2016-01-01

    Stress echocardiography is an integral test in the cardiac diagnostic laboratory and has high sensitivity and specificity. Despite the excellent specificity of stress echocardiography, we continue to see a subset of patients with false-positive tests (defined as <50% diameter stenosis on subsequent coronary angiography). These false-positive findings present a management challenge because it remains unclear if and how to treat these patients. This article reviews relevant clinical studies and their outcomes. Studies suggest that a group of patients develops a hypertensive response to exercise and therefore may have false-positive stress echocardiography. Hence, superior blood pressure control prior to stress echocardiography may prevent some false-positive tests. In addition, a subset of patients has microvascular abnormalities, vasomotor changes, endothelial dysfunction, and/or small vessel coronary disease that can lead to false-positive stress echocardiography. The evidence is insufficient to state that a false-positive stress echocardiography in the absence of obstructive coronary artery disease portends a poor outcome, but considerable evidence shows that some of these patients have microvascular abnormalities and endothelial dysfunction and consequently may benefit from aggressive medical management and further testing.

  4. Nasal ventilation.

    PubMed Central

    Simonds, A. K.

    1998-01-01

    Nasal intermittent positive pressure ventilation is likely to have an increasing role in the management of acute ventilatory failure, weaning, and chronic ventilatory problems. Further improvements in ventilator and mask design will be seen. Appropriate application is likely to reduce both mortality and admissions to intensive care, while domiciliary use can improve life expectancy and/or quality of life in chronic ventilatory disorders. As with any new technique, enthusiasm should not outweigh clear outcome information, and possible new indications should always be subject to careful assessment. Images Figure 2 PMID:9799887

  5. Midfacial and Dental Changes Associated with Nasal Positive Airway Pressure in Children with Obstructive Sleep Apnea and Craniofacial Conditions

    PubMed Central

    Roberts, Soleil D.; Kapadia, Hitesh; Greenlee, Geoff; Chen, Maida L.

    2016-01-01

    Study Objectives: Nasal positive airway pressure (nPAP) for treatment of pediatric obstructive sleep apnea (OSA) is a widespread therapy that currently lacks longitudinal data describing how mask pressure impacts the developing facial skeleton. This retrospective cohort study compared midfacial growth in pediatric patients with underlying craniofacial conditions diagnosed with OSA who were compliant vs. noncompliant with nPAP therapy, and explored correlations between demographic, medical, and sleep variables with annual rate of facial change. Methods: Records from Seattle Children's Hospital's Craniofacial Center and Sleep Disorders Center were reviewed to identify patients prescribed nPAP for OSA with serial cephalographic images obtained during routine clinical care for concomitant craniofacial diagnosis. Lateral cephalometric analysis was used to determine mean annual change in midfacial structures from T1 (pre-nPAP) to T2 (post-nPAP) in compliant vs. noncompliant subjects. Compliance was indicated by nPAP usage of > 20 h/week for > 6 months. Results: 50 subjects were compliant with nPAP therapy (mean age 10.42 years) for an average of 2.57 years, and 50 subjects were noncompliant (mean age 8.53 years). Compliant subjects experienced negative mean annual change (retrusion) of the midface compared to forward growth seen in noncompliant subjects (SNA: −0.57° vs. 0.56°), counterclockwise rotation of palatal plane (SN-PP: −1.15° vs. 0.09°), and upper incisor flaring (U1-SN: 2.41° vs. −0.51°). Conclusions: Pressure to the midface from compliant nPAP use may alter normal facial growth. Cephalometric findings indicate a greater need for collaboration between sleep medicine physicians and orthodontists to monitor midfacial growth during nPAP treatment. Citation: Roberts SD, Kapadia H, Greenlee G, Chen ML. Midfacial and dental changes associated with nasal positive airway pressure in children with obstructive sleep apnea and craniofacial conditions. J Clin

  6. Effects of flow rate and airleak at the nares and mouth opening on positive distending pressure delivery using commercially available high-flow nasal cannula systems: a lung model study.

    PubMed

    Hasan, Rashed A; Habib, Robert H

    2011-01-01

    Use of high-flow humidified nasal cannulas to deliver continuous positive airway pressure in children is increasing. Data on the relationship between the flow values and the corresponding pressures are limited. The purpose of this experiment was to evaluate the relationship between the device, intraprong, and proximal airway pressures and the flow values in a neonatal/pediatric test lung model, using the Vapotherm 2000i and Fisher-Paykel humidified nasal cannulas devices. Using a pediatric size cannula (2-mm inner diameter), we measured the device, intraprong, and proximal airway pressures at random flow values between 0 L/min and 12 L/min with an FIO2 of 0.21 at a temperature of 37°C and 100% humidity. Measurements were repeated for both devices under simulated minimal and moderate nares-prong leak (leak). Effects of varying mouth leak were also studied. All three pressures generally increased with increasing flows with both devices, irrespective of leak. In case of minimal leak, the Fisher-Paykel device generated larger pressures than the Vapotherm device for flows of < 8 L/min, whereas this trend was reversed at higher flows due principally to the pressure release feature of the Fisher-Paykel system. Under minimal leak, the intraprong pressure values varied between 22% and 27% and 20% and 32% of the corresponding device pressure value for Fisher-Paykel and Vapotherm, respectively. The proximal airway pressure was further reduced by about 20% to 30% relative to the intrapong pressure values with the two devices. The device pressure was essentially unaffected by nares-prong leaks or mouth leak. The intraprong pressure and particularly the proximal airway pressure were reduced substantially, as either nares or mouth leak increased. High flow humidified nasal cannulas systems may deliver uncontrolled continuous positive airway pressure to infants. This, along with the potentially large nares and mouth leak effects on any form of continuous positive airway pressure

  7. GPS and odometer data fusion for outdoor robots continuous positioning

    NASA Astrophysics Data System (ADS)

    Pozo-Ruz, Ana; Garcia-Perez, Lia; Garcia-Alegre, Maria C.; Guinea, Domingo; Ribeiro, Angela; Sandoval, Francisco

    2002-02-01

    Present work describes an approximation to obtain the best estimation of the position of the outdoor robot ROJO, a low cost lawnmower to perform unmanned precision agriculture task such are the spraying of pesticides in horticulture. For continuous location of ROJO, two redundant sensors have been installed onboard: a DGPS submetric precision model and an odometric system. DGPS system will allow an absolute positioning of the vehicle in the field, but GPS failures in the reception of the signals due to obstacles and electrical and meteorological disturbance, lead us to the integration of the odometric system. Thus, a robust odometer based upon magnetic strip sensors has been designed and integrated in the vehicle. These sensors continuosly deliver the position of the vehicle relative to its initial position, complementing the DGPS blindness periods. They give an approximated location of the vehicle in the field that can be in turn conveniently updated and corrected by the DGPS. Thus, to provided the best estimation, a fusion algorithm has been proposed and proved, wherein the best estimation is calculated as the maximum value of the join probability function obtained from both position estimation of the onboard sensors. Some results are presented to show the performance of the proposed sensor fusion technique.

  8. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3900 Nasal dilator. (a) Identification. A nasal... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external...

  9. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3900 Nasal dilator. (a) Identification. A nasal... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external...

  10. Epstein-Barr virus-positive blastoid nasal T/natural killer-cell lymphoma in a caucasian.

    PubMed

    Ling, T C; Harris, M; Craven, N M

    2002-04-01

    T/natural killer (NK)-cell lymphoma is a subtype of non-Hodgkin's lymphoma, with frequent cutaneous involvement; it follows an aggressive course. Most cases are reported in Asia, and typically present with nasopharyngeal involvement. There is a distinct variant known as blastoid T/NK-cell lymphoma, which affects elderly, non-Asian patients, with absence of nasal involvement. We report a middle-aged caucasian man who had blastoid T/NK-cell lymphoma with nasal involvement.

  11. Nasal Cancer

    MedlinePlus

    ... the way to your throat as you breathe. Cancer of the nasal cavity and paranasal sinuses is ... be like those of infections. Doctors diagnose nasal cancer with imaging tests, lighted tube-like instruments that ...

  12. The association of asthma, nasal allergies, and positive skin prick tests with obesity, leptin, and adiponectin.

    PubMed

    Newson, R B; Jones, M; Forsberg, B; Janson, C; Bossios, A; Dahlen, S-E; Toskala, E M; Al-Kalemji, A; Kowalski, M L; Rymarczyk, B; Salagean, E M; van Drunen, C M; Bachert, C; Wehrend, T; Krämer, U; Mota-Pinto, A; Burney, P; Leynaert, B; Jarvis, D

    2014-02-01

    Cross-sectional and longitudinal reports show that obese adults have more asthma than non-obese adults. A proposed mechanism is via effects of adipokines (leptin and adiponectin) on the immune system. We wished to measure the associations of asthma and other atopic diseases with serum adipokine levels and to find whether the associations with asthma were strong enough to rule out the possibility that they are secondary to the association of fatness measures with asthma. The Global Asthma and Allergy Network of Excellence (GA(2) LEN) clinical follow-up survey is a clinical survey, embedded in a larger multi-centre cross-sectional postal survey, involving, with a case/control design, enrichment of the sample with subjects with asthma and chronic rhinosinusitis (CRS). We recorded serum leptin or adiponectin in 845 men and 1110 women in 15 centres and also anthropometric measures of fatness including body mass index and waist/hip ratio, current asthma, and specific skin prick and IgE sensitisation. We used inverse sampling-probability-weighted rank and regression statistics to measure population associations of disease outcomes with adipokines in males and females, adjusting for confounders (area, age, smoking history, and number of elder siblings) and also mutually adjusting associations with adipokines and fatness measures. One thousand nine hundred and fifty-five subjects aged 16-77 years had information on leptin or adiponectin levels. Leptin and leptin/adiponectin ratio were positively associated with the level of asthma, especially in females (Somers' D of leptin by asthma score, 0.20; 95% CI, 0.08-0.30; P = 0.00079). These associations were attenuated after adjusting for confounders and became non-significant after additionally adjusting for fatness measures and multiple comparisons. Asthma levels are positively associated with serum leptin. However, we cannot rule out the possibility that this association is secondary to associations of both with fatness

  13. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    PubMed

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  14. Upper Airway Variation and Frequent Alcohol Consumption Can Affect Compliance With Continuous Positive Airway Pressure

    PubMed Central

    Jeong, Jong In; Kim, Hyo Yeol; Hong, Sang Duk; Ryu, Gwanghui; Kim, Su Jin; Lee, Kyung Eun; Dhong, Hun-Jong; Chung, Seung-Kyu

    2016-01-01

    Objectives Compliance with continuous positive airway pressure (CPAP) treatment remains a primary concern for improving treatment outcomes of obstructive sleep apnea. There are few studies that have considered the role of upper airway anatomy on the compliance with CPAP. We hypothesized that upper airway anatomy would influence the compliance with CPAP. Methods One hundred out of 161 consecutive patients were enrolled in this study. The following possible determinants were tested against CPAP use: demographic and anthropometric data, minimal cross-sectional area on acoustic rhinometry, cephalometric and polysomnographic data, questionnaires of Epworth sleepiness scale and Beck depression index, and histories of previous upper airway surgery, degree of nasal obstruction, daily cigarette consumption, and weekly frequency of alcohol intake. Results Univariate analysis showed that histories of previous upper airway surgery and less frequent alcohol consumption, and longer mandibular plane-hyoid length (MP-H) on cephalometry were associated with longer average daily CPAP use. After adjustment for the confounding factors with multiple linear regression analysis, alcohol consumption and MP-H were still associated with the compliance with CPAP significantly. Conclusion To improve compliance with CPAP, careful evaluations of upper airway problems and life style are important before initiating CPAP. PMID:27334512

  15. Continuing Education Workshops in Bioinformatics Positively Impact Research and Careers.

    PubMed

    Brazas, Michelle D; Ouellette, B F Francis

    2016-06-01

    Bioinformatics.ca has been hosting continuing education programs in introductory and advanced bioinformatics topics in Canada since 1999 and has trained more than 2,000 participants to date. These workshops have been adapted over the years to keep pace with advances in both science and technology as well as the changing landscape in available learning modalities and the bioinformatics training needs of our audience. Post-workshop surveys have been a mandatory component of each workshop and are used to ensure appropriate adjustments are made to workshops to maximize learning. However, neither bioinformatics.ca nor others offering similar training programs have explored the long-term impact of bioinformatics continuing education training. Bioinformatics.ca recently initiated a look back on the impact its workshops have had on the career trajectories, research outcomes, publications, and collaborations of its participants. Using an anonymous online survey, bioinformatics.ca analyzed responses from those surveyed and discovered its workshops have had a positive impact on collaborations, research, publications, and career progression.

  16. Routine nasal packing follwoing nasal surgery-Is it necessary?

    PubMed

    Basha, S I; Gupta, D; Kaluskar, S K

    2005-01-01

    The practice of routine nasal packing after nasal surgery is usually customary and not evidence based. Post operative complications, while uncoumon, are sometimes pack related. A retrospective analysis of 110 patients who underwent a variety of nasal operations was performed to determine the incidence of complications when nasal packs were not routinely inserted 9 cases (8.2%) [6 out of these were revision surgeries] needed nasal packing for haemostasis at the end of surgery. 4 cases (3.6%) required to be packed in the immediate post operative period. One patient who required nasal packing developed a unilateral adhesion. No patient developed septal hematoma. The need for routine nasal packing is not supported. Packing should be indicated where there continuous bleeding at.

  17. [A patient with both cocaine-induced nasal septum destruction and antibodies against anti-neutrophil cytoplasmic antibodies (ANCA); potential confusion with Wegener's disease].

    PubMed

    Scheenstra, R J; van Buren, M; Koopman, J P

    2007-10-27

    A 37-year-old male cocaine user presented with continual, sanguinolent nasal obstruction and persistant pain following a nasal operation one year ago. Examination showed crustae, granulations and exposed septal cartilage in the right nasal passage in addition to a considerable septal deviation to the left. No other physical abnormalities were found. A biopsy of the nasal mucosa showed acute necrotic inflammation. The serological examination revealed markedly elevated anti-neutrophil cytoplasmic antibodies (ANCA) titres with positive reactions against proteinase-3, indicating Wegener's disease. Additional testing also showed a positive ANCA reaction for human neutrophil elastase, which made cocaine use a more plausible cause for the nasal abnormalities than Wegener's disease. Treatment consisted of nasal flushing with saline and, for a short period, a nasal tampon with hydrocortisone-oxytetracycline-polymyxin B ointment. However, the patient did, ultimately, develop a septal perforation. Cocaine-induced nasal abnormalities can imitate symptoms that may fit Wegener's disease, including relevant serological ANCA findings.

  18. Midfacial and Dental Changes Associated with Nasal Positive Airway Pressure in Children with Obstructive Sleep Apnea and Craniofacial Conditions.

    PubMed

    Roberts, Soleil D; Kapadia, Hitesh; Greenlee, Geoff; Chen, Maida L

    2016-04-15

    Nasal positive airway pressure (nPAP) for treatment of pediatric obstructive sleep apnea (OSA) is a widespread therapy that currently lacks longitudinal data describing how mask pressure impacts the developing facial skeleton. This retrospective cohort study compared midfacial growth in pediatric patients with underlying craniofacial conditions diagnosed with OSA who were compliant vs. noncompliant with nPAP therapy, and explored correlations between demographic, medical, and sleep variables with annual rate of facial change. Records from Seattle Children's Hospital's Craniofacial Center and Sleep Disorders Center were reviewed to identify patients prescribed nPAP for OSA with serial cephalographic images obtained during routine clinical care for concomitant craniofacial diagnosis. Lateral cephalometric analysis was used to determine mean annual change in midfacial structures from T1 (pre-nPAP) to T2 (post-nPAP) in compliant vs. noncompliant subjects. Compliance was indicated by nPAP usage of > 20 h/week for > 6 months. 50 subjects were compliant with nPAP therapy (mean age 10.42 years) for an average of 2.57 years, and 50 subjects were noncompliant (mean age 8.53 years). Compliant subjects experienced negative mean annual change (retrusion) of the midface compared to forward growth seen in noncompliant subjects (SNA: -0.57° vs. 0.56°), counterclockwise rotation of palatal plane (SN-PP: -1.15° vs. 0.09°), and upper incisor flaring (U1-SN: 2.41° vs. -0.51°). Pressure to the midface from compliant nPAP use may alter normal facial growth. Cephalometric findings indicate a greater need for collaboration between sleep medicine physicians and orthodontists to monitor midfacial growth during nPAP treatment. © 2016 American Academy of Sleep Medicine.

  19. Interstitial radiation therapy for early-stage nasal vestibule cancer: A continuing quest for optimal tumor control and cosmesis

    SciTech Connect

    Levendag, Peter C. . E-mail: p.levendag@erasmusmc.nl; Nijdam, Wideke M.; Moolenburgh, Sanne E. van; Tan, Lisa; Noever, Inge R.T.T.; Rooy, Peter van; Mureau, Marc; Jansen, Peter P.; Munte, Kai; Hofer, Stefan O.P.

    2006-09-01

    Introduction: This article reports on the effectiveness, cosmetic outcome, and costs of interstitial high-dose-rate (HDR) brachytherapy for early-stage cancer of the nasal vestibule (NV) proper and/or columella high-dose-rate (HDR). Methods and Materials: Tumor control, survival, cosmetic outcome, functional results, and costs were established in 64 T1/T2N0 nasal vestibule cancers treated from 1991-2005 by fractionated interstitial radiation therapy (IRT) only. Total dose is 44 Gy: 2 fractions of 3 Gy per day, 6-hour interval, first and last fraction 4 Gy. Cosmesis is noted in the chart by the medical doctor during follow-up, by the patient (visual analog scale), and by a panel. Finally, full hospital costs are computed. Results: A local relapse-free survival rate of 92% at 5 years was obtained. Four local failures were observed; all four patients were salvaged. The neck was not treated electively; no neck recurrence in follow-up was seen. Excellent cosmetic and functional results were observed. With 10 days admission for full treatment, hospital costs amounted to Euro 5772 ($7044). Conclusion: Excellent tumor control, cosmesis, and function of nasal airway passage can be achieved when HDR-IRT for T1/T2N0 NV cancers is used. For the more advanced cancers (Wang classification: T3 tumor stage), we elect to treat by local excision followed by a reconstructive procedure. The costs, admission to hospital inclusive, for treatment by HDR-IRT amounts to Euro 5772 ($7044 US). This contrasts substantially with the full hospital costs when NV cancers are treated by plastic reconstructive surgery, being on average threefold as expensive.

  20. Comparison of conventional continuous positive airway pressure to continuous positive airway pressure titration performed with sleep endoscopy.

    PubMed

    Civelek, Senol; Emre, Ismet Emrah; Dizdar, Denizhan; Cuhadaroglu, Caglar; Eksioglu, Birsen Karaci; Eraslan, Algın Kayar; Turgut, Suat

    2012-03-01

    To evaluate the effect and obtain a pressure value of continuous positive airway pressure (CPAP) under direct visualization using drug-induced sleep endoscopy (DISE) and compare the pressure values with values obtained using conventional CPAP. Prospective, double-blinded, cohort study. Sixteen patients with obstructive sleep apnea syndrome (OSAS) were included in the study. Each patient underwent polysomnographic evaluation. After diagnosis of OSAS, patients underwent conventional CPAP titration. Patients were then taken to the operating theatre and put under sedation, where CPAP titration with nasendoscopy was performed (DISE CPAP). There were no statistically significant differences between the two techniques regarding pressure levels that decreased apneas in conventional CPAP and provided sufficient opening during DISE CPAP. Results with conventional CPAP titration and endoscopy-assisted CPAP titration showed no statistically significant difference. Endoscopy-assisted CPAP is a cheaper and less time consuming alternative to conventional CPAP and has similar results. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  1. Nasal carriage of multi-drug resistant Panton-Valentine leucocidin-positive methicillin-resistant Staphylococcus aureus in children in Tripoli-Libya.

    PubMed

    Al-haddad, Omaima H; Zorgani, Abdulaziz; Ghenghesh, Khalifa Sifaw

    2014-04-01

    Methicillin-resistant Staphylococcus aureus (MRSA) colonized children are at an increased risk of developing infections than methicillin-sensitive S. aureus colonized children. Nasal specimens from inpatient children, mothers of inpatient children, healthcare workers, and outpatient children at Tripoli Children Hospital (TCH) were examined for MRSA by chromogenic MRSA ID medium. Susceptibility of MRSA isolates to antibiotics was determined by the disc diffusion method. The nasal carriage rate of MRSA among inpatient children (8.3%, 24 of 289), their mothers (11%, 22 of 200), and healthcare workers (12.4%, 22 of 178) was significantly higher than among outpatient children (2.2%, 2 of 91) (P < 0.05, P < 0.02, and P < 0.006, respectively). Of the examined MRSA isolates (N = 35) 10 (28.6%) were positive for Panton-Valentine leucocidin genes by polymerase chain reaction. Multidrug resistance was found in 24.3% (17 of 70) of MRSA isolates. Nasal carriage of multidrug-resistant Panton-Valentine leucocidin-positive MRSA is not uncommon among inpatient children and their mothers in Tripoli.

  2. Personality correlates of adherence with continuous positive airway pressure (CPAP).

    PubMed

    Moran, Alicia M; Everhart, Daniel Erik; Davis, Claude Ervin; Wuensch, Karl L; Lee, Daniel O; Demaree, Heath A

    2011-12-01

    Adherence with continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA) has been problematic. Understanding the factors associated with nonadherence may assist with psychosocial interventions. The objective of this study was to examine the relationship between adherence and three measures of personality and coping strategies. Ratings on the behavioral inhibition system/behavioral activation system (BIS/BAS) scales, the ways of coping inventory, and a broad personality measure (mini-IPIP) were analyzed with a binary logistic regression among 63 subjects, adult men (31) and women (32), diagnosed with OSA. Data from the CPAP device was obtained following initial 30 days at minimum, with adherence defined as >4 h/night on 70% of nights. Elevated BIS was the strongest predictor of nonadherence (r = -.452, p < .01), followed by neuroticism. The regression correctly classified 73% of participants as adherent or nonadherent. Nonadherence is associated with elevated BIS scores and neuroticism, which indicates that personality factors play a role in determining adherence to CPAP. Although more research is needed to draw firm conclusions, the differences noted in BIS may also point toward differences in neurophysiological function. The BIS scale may be a useful tool for predicting nonadherence and assist with the development of intervention strategies that will increase adherence.

  3. Usage of four-phase high-resolution rhinomanometry and measurement of nasal resistance in sleep-disordered breathing.

    PubMed

    Toh, Song-Tar; Lin, Cheng-Hui; Guilleminault, Christian

    2012-10-01

    To investigate the ease of use of four-phase high-resolution rhinomanometry (HRR), a new way of measuring nasal resistance, in measuring change in nasal resistance from supine to inclined position in a clinical sleep laboratory setting, and to correlate findings with continuous positive airway pressure (CPAP) tolerance. Retrospective review of clinical charts. Forty successively seen Caucasian subjects diagnosed with sleep-disordered breathing (SDB) with complete charts were analyzed. Using four-phase HRR and acoustic rhinometry, nasal resistance and minimal cross-sectional area of the nasal cavity were objectively measured with the patient in the supine position and repeated in the inclined position (30° from the horizontal plane), respectively. From the supine to inclined position, reduction in total nasal resistance was observed in 87.5% (35 out of 40). There was a mean reduction of nasal resistance by 37.1 ± 21.6%. Five (12.5%) out of 40 subjects showed no change or mild increase in nasal resistance. Subjects with nasal resistance unresponsive to the inclined position change tended to have difficulty using nasal CPAP based on downloaded compliance card data. Four-phase HRR and acoustic rhinometry are tests that can be easily performed by sleep specialists to characterize nasal resistance in SDB patients and determine changes in resistance with positional changes. In this study, we found that patients who did not demonstrate a decrease in nasal resistance with inclined position were more likely to be noncompliant with nasal CPAP. These measurements may help us objectively identify patients who might have trouble tolerating nasal CPAP. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  4. Computer-aided design and manufacturing construction of a surgical template for craniofacial implant positioning to support a definitive nasal prosthesis.

    PubMed

    Ciocca, Leonardo; Fantini, Massimiliano; De Crescenzio, Francesca; Persiani, Franco; Scotti, Roberto

    2011-08-01

    To design a surgical template to guide the insertion of craniofacial implants for nasal prosthesis retention. The planning of the implant position was obtained using software for virtual surgery; the positions were transferred to a free-form computer-aided design modeling software and used to design the surgical guides. A rapid prototyping system was used to 3D-print a three-part template: a helmet to support the others, a starting guide to mark the skin before flap elevation, and a surgical guide for bone drilling. An accuracy evaluation between the planned and the placed final position of each implant was carried out by measuring the inclination of the axis of the implant (angular deviation) and the position of the apex of the implant (deviation at apex). The implant in the glabella differed in angulation by 7.78°, while the two implants in the premaxilla differed by 1.86 and 4.55°, respectively. The deviation values at the apex of the implants with respect to the planned position were 1.17 mm for the implant in the glabella and 2.81 and 3.39 mm, respectively, for those implanted in the maxilla. The protocol presented in this article may represent a viable way to position craniofacial implants for supporting nasal prostheses. © 2010 John Wiley & Sons A/S.

  5. Impact of group education on continuous positive airway pressure adherence.

    PubMed

    Lettieri, Christopher J; Walter, Robert J

    2013-06-15

    To compare the impact of a group educational program versus individual education on continuous positive airway pressure (CPAP) adherence. Post hoc assessment of a performance improvement initiative designed to improve clinic efficiency, access to care, and time to initiate therapy. Consecutive patients newly diagnosed with obstructive sleep apnea (OSA) initiating CPAP therapy participated in either an individual or group educational program. The content and information was similar in both strategies. Of 2,116 included patients, 1,032 received education regarding OSA and CPAP through a group clinic, and 1,084 received individual education. Among the cohort, 76.6% were men, mean age 48.3 ± 9.2 years, mean body mass index 29.6 ± 4.6 kg/m(2), and mean apnea-hypopnea index was 33.3 ± 24.4 events/hour. Baseline characteristics were similar between groups. CPAP adherence was significantly greater in those participating in a group program than those receiving individual education. Specifically, CPAP was used for more nights (67.2% vs. 62.1%, p = 0.02) and more hours per night during nights used (4.3 ± 2.1 vs. 3.7 ± 2.8, p = 0.03). Further, fewer individuals discontinued therapy (10.6% vs. 14.5%, p < 0.001), more achieved regular use of CPAP (45.2%. vs. 40.6%, p = 0.08), and time to initiate therapy was shorter (13.2 ± 3.1 versus 24.6 ± 7.4 days, p < 0.001). Group education resulted in a 3- to 4-fold increase in the number of patients seen per unit time. A group educational program facilitated improved CPAP adherence. If confirmed by prospective randomized studies, group CPAP education may be an appropriate alternative to individual counseling, may improve acceptance of and adherence to therapy, and decrease time to treatment.

  6. Myofunctional therapy improves adherence to continuous positive airway pressure treatment.

    PubMed

    Diaféria, Giovana; Santos-Silva, Rogerio; Truksinas, Eveli; Haddad, Fernanda L M; Santos, Renata; Bommarito, Silvana; Gregório, Luiz C; Tufik, Sergio; Bittencourt, Lia

    2017-05-01

    Few studies have investigated myofunctional therapy in patients with obstructive sleep apnea syndrome (OSAS). The objective of this study was to evaluate the effect of myofunctional therapy on continuous positive airway pressure (CPAP) adherence. The study was registered at ClinicalTrials.gov (NCT01289405). Male patients with OSAS were randomly divided into four treatment groups: placebo, patients undergoing placebo myofunctional therapy (N = 24); myofunctional therapy, undergoing myofunctional therapy (N = 27); CPAP, undergoing treatment with CPAP (N = 27); and combined, undergoing CPAP therapy and myofunctional therapy (N = 22). All patients underwent evaluations before and after 3 months of treatment evaluation and after 3 weeks of washout. Evaluations included Epworth sleepiness scale (ESS), polysomnography, and myofunctional evaluation. The 100 men had a mean age of 48.1 ± 11.2 years, body mass index of 27.4 ± 4.9 kg/m(2), ESS score of 12.7 ± 3.0, and apnea-hypopnea index (AHI) of 30.9 ± 20.6. All treated groups (myofunctional therapy, CPAP, and combined myofunctional therapy with CPAP) showed decreased ESS and snoring, and the myofunctional therapy group maintained this improvement after the "washout" period. AHI reduction occurred in all treated groups and was more significant in CPAP group. The myofunctional therapy and combined groups showed improvement in tongue and soft palate muscle strength when compared with the placebo group. The association of myofunctional therapy to CPAP (combined group) showed an increased adherence to CPAP compared with the CPAP group. Our results suggest that in patients with OSAS, myofunctional therapy may be considered as an adjuvant treatment and an intervention strategy to support adherence to CPAP.

  7. Eosinophil count in nasal mucosa is more suitable than the number of ICAM-1-positive nasal epithelial cells to evaluate the severity of house dust mite-sensitive allergic rhinitis: a clinical correlation study.

    PubMed

    Klaewsongkram, Jettanong; Ruxrungtham, Kiat; Wannakrairot, Pongsak; Ruangvejvorachai, Preecha; Phanupak, Praphan

    2003-09-01

    House dust mite (HDM)-sensitive allergic rhinitis is a perennial rhinitis with persistent nasal inflammation. Currently, there are no reliable parameters to monitor the severity of perennial allergic rhinitis. The purpose of this study was to evaluate correlations between clinical and laboratory parameters in patients with HDM-sensitive allergic rhinitis. We measured nasal symptoms, did the Dermatophagoides pteronyssinus (Der P) skin prick test (SPT), evaluated the Der P allergen nasal challenge threshold, and laboratory parameters [(1) inflammatory cell count from nasal mucosal scraping specimens: eosinophils and neutrophils and (2) immunocytochemistry: ICAM-1 expression on nasal epithelial cells] in 20 cases of HDM-sensitive allergic rhinitis and performed correlation tests between all parameters. The wheal diameter induced by Der P SPT was significantly correlated with the Der P allergen nasal challenge threshold (p = 0.001). The number of eosinophils from nasal mucosal scrapping specimens was correlated with the ICAM-1 expression on nasal epithelial cells (p = 0.039), the number of neutrophils from nasal mucosal scrapping specimens (p = 0.001), and nasal stuffiness (p = 0.037) but did not correlate with total nasal symptom scores. Clinical symptoms of HDM-sensitive allergic rhinitis showed a poor correlation with inflammatory parameters. The eosinophil count in nasal mucosa is correlated with ICAM-1 expression and more suitable than ICAM-1 levels to evaluate the severity of HDM-sensitive allergic rhinitis. This study also supports the role of the SPT in the diagnosis of nasal allergy to HDM. Copyright 2003 S. Karger AG, Basel

  8. Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure

    PubMed Central

    Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-01-01

    ABSTRACT Objective: To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Methods: Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Results: Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Conclusions: Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. PMID:27812636

  9. Nasal polyposis

    PubMed Central

    Brown, Gerald A.

    1969-01-01

    A review of 313 cases of nasal polyposis indicates that there is a high incidence of recurrence in this disease. Other nasal pathology affects a significant number of these patients. Simple surgical removal of the polypi by a transnasal route is the common mode of treatment. PMID:4187956

  10. Matizaciones ortologicas: La nasalizacion (Orthoepic Variations: Nasalization)

    ERIC Educational Resources Information Center

    Prado, Eduardo

    1975-01-01

    This paper discusses the slight nasalization occurring in Spanish to the vowels preceding "n" or "m" when placed before a "b" or "p" between two nasal consonants, in word-initial position or in elision. (Text is in Spanish.) (CHK)

  11. Positioning Continuing Education Computer Programs for the Corporate Market.

    ERIC Educational Resources Information Center

    Tilney, Ceil

    1993-01-01

    Summarizes the findings of the market assessment phase of Bellevue Community College's evaluation of its continuing education computer training program. Indicates that marketing efforts must stress program quality and software training to help overcome strong antiacademic client sentiment. (MGB)

  12. When pressure is positive: a literature review of the prehospital use of continuous positive airway pressure.

    PubMed

    Williams, Brett; Boyle, Malcolm; Robertson, Nicole; Giddings, Coco

    2013-02-01

    Heart failure poses a significant burden of disease, resulting in 2,658 Australian deaths in 2008, and listed as an associated cause of death in a further 14,466 cases. Common in the hospital setting, continuous positive airway pressure (CPAP) therapy is a non-invasive ventilation technique used to prevent airway collapse and manage acute pulmonary edema (APO). In the hospital setting, CPAP has been known to decrease the need for endotracheal intubation in patients with APO. Therefore the objective of this literature review was to identify the effectiveness of CPAP therapy in the prehospital environment. A review of selected electronic medical databases (Cochrane, Medline, EMBASE, and CINAHL) was conducted from their commencement date through the end of May 2012. Inclusion criterion was any study type reporting the use of CPAP therapy in the prehospital environment, specifically in the treatment of heart failure and acute pulmonary edema. References of relevant articles were also reviewed. The literature search located 1,253 articles, 12 of which met the inclusion criteria. The majority of studies found that the use of CPAP therapy in the prehospital environment is associated with reduced short-term mortality as well as reduced rates of endotracheal intubation. Continuous positive airway pressure therapy was also shown to improve patient vital signs during prehospital transport and reduce myocardial damage. The studies conducted of prehospital use of CPAP to manage APO have all demonstrated improvement in patient outcomes in the short term. Available evidence suggests that the use of CPAP therapy in the prehospital environment may be beneficial to patients with acute pulmonary edema as it can potentially decrease the need for endotracheal intubation, improve vital signs during transport to hospital, and improve short-term mortality.

  13. Nasal and cutaneous aspergillosis in a goat.

    PubMed

    do Carmo, P M S; Portela, R A; de Oliveira-Filho, J C; Dantas, A F M; Simões, S V D; Garino, F; Riet-Correa, F

    2014-01-01

    Nasal and cutaneous aspergillosis is reported in an adult goat. The clinical signs were severe respiratory distress due to partial nasal obstruction, bilateral mucopurulent nasal discharge, skin nodules on the ears and dorsal nasal region and focal depigmentation of the ventral commissure of the right nostril. At necropsy examination, sagittal sectioning of the head revealed a yellow irregular mass extending from the nasal vestibule to the frontal portion of the nasal cavity. Microscopically, there was pyogranulomatous rhinitis and dermatitis, with numerous intralesional periodic acid-Schiff-positive fungal hyphae morphologically suggestive of Aspergillus spp. Aspergillus niger was isolated by microbiological examination.

  14. Clinical evaluation of a novel internal nasal dilation stent for the improvement of nasal breathing.

    PubMed

    Brandt, Michael G; Moore, Corey C; Doyle, Philip C

    2008-05-01

    This study assessed rhinometric improvement in nasal airflow, perceived comfort, and the utility of nasal dilation devices for individuals with nasal obstruction treated with an external nasal dilator (END) or a novel internal nasal dilation stent (INDS). Prospective, randomized, crossover trial. Individuals with symptoms of nasal obstruction. Twenty-three participants underwent rhinometry and a trial with a novel INDS and a validated END. Devices were used in a randomized, crossover fashion. Nasal airflow, maximum use, continuous use, comfort, and challenge with these devices were assessed. The END and INDS showed greater nasal airflow from baseline, with the INDS being significantly better than the END. The INDS was used significantly more than the END, and demonstrated significantly greater comfort and less associated challenge. The novel INDS showed 3.4 times improved nasal airflow from baseline, was used maximally and continuously longer than a validated END, and was judged to be significantly more tolerable.

  15. Desmopressin Nasal

    MedlinePlus

    ... stop some types of bleeding in people with hemophilia (condition in which the blood does not clot ... When desmopressin nasal (Stimate®) is used to treat hemophilia and von Willebrand's disease, 1 to 2 spray(s) ...

  16. Positioning a University Outreach Center: Strategies for Support and Continuation.

    ERIC Educational Resources Information Center

    Skivington, Kristen D.

    1998-01-01

    Argues that a strong case can be made for supporting outreach as a value-added function in a university. Specific strategies for positioning outreach within the university by developing a power base are outlined. The case of the University of Michigan-Flint is offered as an example of this approach. Seven lessons learned in the process are noted.…

  17. Positioning a University Outreach Center: Strategies for Support and Continuation.

    ERIC Educational Resources Information Center

    Skivington, Kristen D.

    1998-01-01

    Argues that a strong case can be made for supporting outreach as a value-added function in a university. Specific strategies for positioning outreach within the university by developing a power base are outlined. The case of the University of Michigan-Flint is offered as an example of this approach. Seven lessons learned in the process are noted.…

  18. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea*

    PubMed Central

    de Andrade, Rafaela Garcia Santos; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect. PMID:25610507

  19. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea.

    PubMed

    Andrade, Rafaela Garcia Santos de; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.

  20. The use of high-flow nasal cannula in the pediatric emergency department.

    PubMed

    Slain, Katherine N; Shein, Steven L; Rotta, Alexandre T

    2017-08-15

    To summarize the current literature describing high-flow nasal cannula use in children, the components and mechanisms of action of a high-flow nasal cannula system, the appropriate clinical applications, and its role in the pediatric emergency department. A computer-based search of PubMed/MEDLINE and Google Scholar for literature on high-flow nasal cannula use in children was performed. High-flow nasal cannula, a non-invasive respiratory support modality, provides heated and fully humidified gas mixtures to patients via a nasal cannula interface. High-flow nasal cannula likely supports respiration though reduced inspiratory resistance, washout of the nasopharyngeal dead space, reduced metabolic work related to gas conditioning, improved airway conductance and mucociliary clearance, and provision of low levels of positive airway pressure. Most data describing high-flow nasal cannula use in children focuses on those with bronchiolitis, although high-flow nasal cannula has been used in children with other respiratory diseases. Introduction of high-flow nasal cannula into clinical practice, including in the emergency department, has been associated with decreased rates of endotracheal intubation. Limited prospective interventional data suggest that high-flow nasal cannula may be similarly efficacious as continuous positive airway pressure and more efficacious than standard oxygen therapy for some patients. Patient characteristics, such as improved tachycardia and tachypnea, have been associated with a lack of progression to endotracheal intubation. Reported adverse effects are rare. High-flow nasal cannula should be considered for pediatric emergency department patients with respiratory distress not requiring immediate endotracheal intubation; prospective, pediatric emergency department-specific trials are needed to better determine responsive patient populations, ideal high-flow nasal cannula settings, and comparative efficacy vs. other respiratory support modalities

  1. Impact of Randomization, Clinic Visits, and Medical and Psychiatric Cormorbidities on Continuous Positive Airway Pressure Adherence in Obstructive Sleep Apnea

    PubMed Central

    Budhiraja, Rohit; Kushida, Clete A.; Nichols, Deborah A.; Walsh, James K.; Simon, Richard D.; Gottlieb, Daniel J.; Quan, Stuart F.

    2016-01-01

    Study Objectives: To evaluate factors associated with continuous positive airway pressure (CPAP) adherence in patients with obstructive sleep apnea (OSA) in the Apnea Positive Pressure Long-term Efficacy Study (APPLES) cohort. Methods: The data from a prospective 6-mo multicenter randomized controlled trial with 558 subjects randomized to active CPAP and 547 to sham CPAP were analyzed to assess adherence to CPAP during first 2 mo (early period) and during months 5-6 (late period). Results: Participants randomized to active CPAP had higher hours of nightly adherence compared to the sham CPAP group at both 2 (4.9 ± 2.0 h versus 4.07 ± 2.14 h, p < 0.001) and 6 mo (4.70 ± 2.08 h versus 3.41 ± 2.19 h, p < 0.001). Those assigned to sham CPAP were more likely to correctly identify their treatment group (70.0% versus 55.2%, p < 0.001). Irrespective of treatment group assignment, those who believed they were receiving active CPAP had higher hours of adherence than those who thought they were in the sham CPAP group at both 2 mo (4.91 ± 2.01 versus 4.17 ± 2.17, p < 0.001) and 6 mo (4.65 ± 2.10 versus 3.65 ± 2.22, p < 0.001). Among those randomized to active CPAP, older age was significantly related to CPAP use > 4 h per night. Presence of cardiovascular disorders was associated with higher hours of CPAP use, whereas presence of anxiety was associated with a trend toward lower hours of CPAP use. Presence of nasal congestion was associated with a decrease in mean daily CPAP use between the early and the late adherence period. The adherence during the week prior to a clinic visit was higher than the average adherence during the 2-mo period prior to the visit. Conclusions: Randomization to active therapy, belief that one is in the active treatment group, older age, and possibly presence of cardiovascular disorders are positively linked to CPAP adherence. Nasal congestion and anxiety are negatively associated with CPAP adherence. CPAP nightly usage increases as clinic

  2. Clinical verification of patients with obstructive sleep apnea provided with a customized cushion for continuous positive airway pressure.

    PubMed

    Cheng, Yih-Lin; Hsu, Ding-Yang; Lee, Hsin-Chien; Bien, Mauo-Ying

    2015-01-01

    Patients with obstructive sleep apnea may stop breathing momentarily during sleep because of a narrow upper respiratory tract. One of the main treatments for obstructive sleep apnea is continuous positive airway pressure. However, after long-term treatment, patients tend to complain about the leakage, inconvenience, and discomfort of the nasal mask. The purpose of the study was to develop customized cushions and compare the clinical performance of the customized cushion with the conventional one. Each participant's face was replicated by using a 3-dimensional scanner and reverse-engineering technology, and computer numerical control techniques were used to design and manufacture customized cushions. Forty participants were randomly divided into 2 groups, a control group with conventional cushions and an experimental group with customized cushions. The saturation level of peripheral oxygen, apnea-hypopnea index, leakage data, and answers to a comfort questionnaire were examined. Customized and conventional cushions were compared with independent sampling t tests and relational analyses. A significant difference was found in the apnea-hypopnea index (P=.001) of participants with the customized cushion and those with the conventional cushion. Participants with the conventional cushion had a lower apnea-hypopnea index. The customized cushion applied less headgear force and fit better than the conventional cushion. The leakage volume, saturation of peripheral oxygen (SpO2), treatment compliance, and degree of comfort were not significantly different between the groups. Customized nasal mask cushions fit better and reduce the force applied by the headgear. Participants using a customized cushion showed an improved apnea-hypopnea index. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Effect of continuous positive airway pressure (CPAP) therapy on IL-23 in patients with obstructive sleep apnea.

    PubMed

    Can, Murat; Uygur, Fırat; Tanrıverdi, Hakan; Acıkgoz, Bilgehan; Alper, Barıs; Guven, Berrak

    2016-12-01

    Obstructive sleep apnea syndrome (OSAS) is a common sleep disorder characterized by repeated episodes of apnea and hypopnea during sleep. Continuous positive airway pressure (CPAP) is the most effective method for treating OSAS and alleviating the patients' symptoms. The aim of this study was to assess the effect of 3-month CPAP therapy on serum levels of IL-23 in patients with OSAS. Twenty-three patients with newly diagnosed moderate-to-severe OSAS who had not yet started nasal CPAP treatment were prospectively enrolled. All of the subjects underwent simple spirometry and an overnight sleep study. Twenty-seven healthy individuals without OSAS were also recruited as the control group. Serum IL-23 and C-reactive protein (CRP) levels were measured before and after 3 months of CPAP therapy. There was no significant difference between moderate and severe OSAS patients in IL-23 and CRP, but both parameters were significantly higher than control group. The CPAP treatment produced a significant decrease in the levels of the inflammatory mediators CRP and IL-23 in patients. Changes in IL-23 were positively correlated with changes in AHI and in CRP. In conclusion, based on these results, serum IL-23 levels reflect OSAS-related systemic inflammation and are a useful marker for improvement in OSAS following CPAP therapy.

  4. Objective monitoring of nasal patency and nasal physiology in rhinitis.

    PubMed

    Nathan, Robert A; Eccles, Ron; Howarth, Peter H; Steinsvåg, Sverre K; Togias, Alkis

    2005-03-01

    impaired mucociliary clearance and altered nasal responsiveness. Measures exist for the monitoring of these aspects of nasal dysfunction. Although measures of mucociliary clearance are simple to perform, they have a poor record of reproducibility. Their incorporation into clinical trials is thus questionable, although positive outcomes from therapeutic intervention have been reported. Measures of nasal responsiveness are at present largely confined to research studies investigating disease mechanisms in allergic and nonallergic rhinitis. The techniques are insufficiently standardized to be applied to multicenter clinical trials but could be used in limited-center studies to gain insight into the regulatory effects of different therapeutic modalities.

  5. Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure.

    PubMed

    Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-01-01

    To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. Determinar se o uso de um travesseiro de gel com recortes laterais para acomodar a máscara de continuous positive airway pressure (CPAP, pressão positiva contínua nas vias aéreas) e diminuir a temperatura em torno da cabeça melhora a eficácia do tratamento com auto-CPAP e a adesão dos pacientes ao tratamento. Foram incluídos no estudo 23 pacientes consecutivos com apneia obstrutiva do sono que nunca haviam recebido tratamento com CPAP. Os

  6. Effects of Nasal Port Area on Perception of Nasality and Measures of Nasalance Based on Computational Modeling

    PubMed Central

    Bunton, Kate

    2015-01-01

    Objective The purpose of this study was to extend previously published modeling work examining the relation between nasal port opening, measures of nasalance, and perceptual ratings of nasality by experienced listeners for three simulated English corner vowels, /i/, /u/, and /ɑ/. Design Samples were generated using a computational model that allowed for exact control of nasal port size and direct measures of nasalance. Perceptual ratings were obtained using a paired stimulus presentation. Participants Four experienced listeners. Main Outcome Measures Nasalance and perceptual ratings of nasality. Results Findings indicate that perceptual ratings of nasality and nasalance increased for samples generated with nasal port areas up to and including 0.16 cm2 but plateaued in samples generated with larger nasal port areas. No vowel differences were noted for perceptual ratings. Conclusions This work extends previously published work by including nasal port areas representative of those reported in the literature for clinical populations, however, continued work using samples with varied phonetic context, and varying suprasegmental and temporal characteristics are needed. PMID:24437587

  7. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and

  8. Does post septoplasty nasal packing reduce complications?

    PubMed

    Naghibzadeh, Bijan; Peyvandi, Ali Asghar; Naghibzadeh, Ghazal

    2011-01-01

    The main issues in nasal surgery are to stabilize the nose in the good position after surgery and preserve the cartilages and bones in the favorable situation and reduce the risk of deviation recurrence. Also it is necessary to avoid the synechia formation, nasal valve narrowing, hematoma and bleeding. Due to the above mentioned problems and in order to solve and minimize them nasal packing, nasal splint and nasal mold have been advised. Patients for whom the nasal packing used may faced to some problems like naso-pulmonary reflex, intractable pain, sleep disorder, post operation infection and very dangerous complication like toxic shock syndrome. We have two groups of patients and three surgeons (one of the surgeons used post operative nasal packing in his patients and the two others surgeons did not).Complications and morbidities were compared in these two groups. Comparing the two groups showed that the rate of complication and morbidities between these two groups were same and the differences were not valuable, except the pain and discomfort post operatively and at the time of its removal. Nasal packing has several risks for the patients while its effects are not studied. Septoplasty can be safely performed without postoperative nasal packing. Nasal packing had no main findings that compensated its usage. Septal suture is one of the procedures that can be used as alternative method to nasal packing. Therefore the nasal packing after septoplasty should be reserved for the patients with increased risk of bleeding.

  9. Airflow patterns in a human nasal model

    SciTech Connect

    Hornung, D.E.; Leopold, D.A.; Youngentob, S.L.; Sheehe, P.R.; Gagne, G.M.; Thomas, F.D.; Mozell, M.M.

    1987-02-01

    Nasal airflow patterns were studied by using xenon 133 gas to image the course taken by air as it flowed through a plastic model of the human nasal cavity. The model was produced from the head of a human cadaver, and was anatomically correct. A needle catheter was used to infuse the radioactive xenon into a continuous flow of room air maintained through the model by a variable vacuum source connected to the nasopharynx. The radioactive gas was infused at one of five release sites in the nostril, and the distribution of the radioactivity was imaged in the sagittal plane with a scintillation camera. The data were organized to show the activity in six contiguous regions of the midnose. For each catheter, release site activity patterns were determined for three flow rates. The results of this experiment showed that both catheter position and flow rate had significant and reproducible effects on the distribution of radioactivity within the model.

  10. Post Septorhinoplasty Custom-Made Unilateral Nasal Stent for Nasal Cleft Deformity

    PubMed Central

    Rathee, Manu; Bhoria, Mohaneesh; Boora, Priyanka

    2015-01-01

    Context: Nasal cleft deformity is a complicated problem. Utilization of nasal stent in post septorhinoplastyaims at establishing and maintaining airway patency, tissue position, and reduces tissue contracture after surgery. Case Report: A 16-year-old female patient presented with history of surgical reconstruction of congenital cleft lip and cleft palate with secondary septorhinoplasty of nasal cleft deformity. Patient was referred for nasal stent 1 week after septorhinoplasty. This case report provides a novel technique for fabrication of esthetic nasal stent after postseptorhinoplasty for secondary cleft nose deformity correction. Conclusion: This case report presents a simple, convenient technique for nasal stent fabrication for prevention of restenosis for cleft nose deformity post secondary septorhinoplasty. Provision of nasal stent allows breathing, maintains esthetics, comfort, nasal patency, and contour with minimal discomfort. PMID:25789253

  11. Sharing More than Friendship — Nasal Colonization with Coagulase-Positive Staphylococci (CPS) and Co-Habitation Aspects of Dogs and Their Owners

    PubMed Central

    Walther, Birgit; Hermes, Julia; Cuny, Christiane; Wieler, Lothar H.; Vincze, Szilvia; Abou Elnaga, Yassmin; Stamm, Ivonne; Kopp, Peter A.; Kohn, Barbara; Witte, Wolfgang; Jansen, Andreas; Conraths, Franz J.; Semmler, Torsten; Eckmanns, Tim; Lübke-Becker, Antina

    2012-01-01

    Background Since the relationship between dogs and their owners has changed, and dogs moved from being working dogs to family members in post-industrial countries, we hypothesized that zoonotic transmission of opportunistic pathogens like coagulase positive staphylococci (CPS) is likely between dogs and their owners. Methodology/Principal Findings CPS- nasal carriage, different aspects of human-to-dog relationship as well as potential interspecies transmission risk factors were investigated by offering nasal swabs and a questionnaire to dog owners (108) and their dogs (108) at a dog show in 2009. S. aureus was found in swabs of 20 (18.5%) humans and two dogs (1.8%), and spa types which correspond to well known human S. aureus lineages dominated (e.g. CC45, CC30 and CC22). Multilocus sequence typing (MLST) of the two canine strains revealed ST72 and ST2065 (single locus variant of ST34). Fifteen dogs (13.9%) and six owners (5.6%) harboured S. pseudintermedius, including one mecA-positive human isolate (MRSP). Pulsed field gel electrophoresis (PFGE) revealed that one dog/owner pair harboured indistinguishable S. pseudintermedius- isolates of ST33. Ten (48%) of the 21 S. pseudintermedius-isolates showed resistance towards more than one antimicrobial class. 88.9% of the dog owners reported to allow at least one dog into the house, 68.5% allow the dog(s) to rest on the sofa, 39.8% allow their dogs to come onto the bed, 93.5% let them lick their hands and 52.8% let them lick their face. Bivariate analysis of putative risk factors revealed that dog owners who keep more than two dogs have a significantly higher chance of being colonized with S. pseudintermedius than those who keep 1–2 dogs (p<0.05). Conclusions/Recommendations In conclusion, CPS transmission between dog owners and their dogs is possible. Further investigation regarding interspecies transmission and the diverse adaptive pathways influencing the epidemiology of CPS (including MRSA and MRSP) in different

  12. Sharing more than friendship--nasal colonization with coagulase-positive staphylococci (CPS) and co-habitation aspects of dogs and their owners.

    PubMed

    Walther, Birgit; Hermes, Julia; Cuny, Christiane; Wieler, Lothar H; Vincze, Szilvia; Abou Elnaga, Yassmin; Stamm, Ivonne; Kopp, Peter A; Kohn, Barbara; Witte, Wolfgang; Jansen, Andreas; Conraths, Franz J; Semmler, Torsten; Eckmanns, Tim; Lübke-Becker, Antina

    2012-01-01

    Since the relationship between dogs and their owners has changed, and dogs moved from being working dogs to family members in post-industrial countries, we hypothesized that zoonotic transmission of opportunistic pathogens like coagulase positive staphylococci (CPS) is likely between dogs and their owners. CPS- nasal carriage, different aspects of human-to-dog relationship as well as potential interspecies transmission risk factors were investigated by offering nasal swabs and a questionnaire to dog owners (108) and their dogs (108) at a dog show in 2009. S. aureus was found in swabs of 20 (18.5%) humans and two dogs (1.8%), and spa types which correspond to well known human S. aureus lineages dominated (e.g. CC45, CC30 and CC22). Multilocus sequence typing (MLST) of the two canine strains revealed ST72 and ST2065 (single locus variant of ST34). Fifteen dogs (13.9%) and six owners (5.6%) harboured S. pseudintermedius, including one mecA-positive human isolate (MRSP). Pulsed field gel electrophoresis (PFGE) revealed that one dog/owner pair harboured indistinguishable S. pseudintermedius- isolates of ST33. Ten (48%) of the 21 S. pseudintermedius-isolates showed resistance towards more than one antimicrobial class. 88.9% of the dog owners reported to allow at least one dog into the house, 68.5% allow the dog(s) to rest on the sofa, 39.8% allow their dogs to come onto the bed, 93.5% let them lick their hands and 52.8% let them lick their face. Bivariate analysis of putative risk factors revealed that dog owners who keep more than two dogs have a significantly higher chance of being colonized with S. pseudintermedius than those who keep 1-2 dogs (p<0.05). In conclusion, CPS transmission between dog owners and their dogs is possible. Further investigation regarding interspecies transmission and the diverse adaptive pathways influencing the epidemiology of CPS (including MRSA and MRSP) in different hosts is needed.

  13. A systematic technical review of the systems for the continuous positive airway pressure.

    PubMed

    Chiumello, D; Esquinas, A M; Moerer, O; Terzi, N

    2012-12-01

    Continuous positive airway pressure (CPAP) is the application in the airways of continuous positive pressure, close to the positive end expiratory pressure. The two common available systems are by a continuous (high/low) flow system and by a mechanical ventilator. Aim of this study was to compare the mechanical performance of the CPAP systems in intubated and not intubated patients. Medical literature databases (MEDLINE and EMBASE) were searched for articles on "clinical trials" and "randomized controlled trials". The key words "continuous positive airway pressure" and "CPAP", were combined with any of these key words: adult, work of breathing, continuous flow, mechanical valve, water valve, balloon reservoir, mechanical ventilator, pressure triggering, flow triggering, lung model, demand valve, equipment. Thirty-two articles (18 human and 14 bench studies) met the inclusion criteria. The continuous flow systems are able to maintain acceptable airway pressure variations during normal breathing. The most recent mechanical ventilators equipped with flow by systems compared to the first one, presented a similar or better work of breathing compared to the continuous flow systems due to the application of a little amount of pressure support. Although the use of a continuous flow is cheaper compared to mechanical ventilators, it does not allow a continuous respiratory monitoring.

  14. Continuous positive airway pressure for children with undifferentiated respiratory distress in Ghana: an open-label, cluster, crossover trial.

    PubMed

    Wilson, Patrick T; Baiden, Frank; Brooks, Joshua C; Morris, Marilyn C; Giessler, Katie; Punguyire, Damien; Apio, Gavin; Agyeman-Ampromfi, Akua; Lopez-Pintado, Sara; Sylverken, Justice; Nyarko-Jectey, Kwadwo; Tagbor, Harry; Moresky, Rachel T

    2017-06-01

    In low-income and middle-income countries, invasive mechanical ventilation is often not available for children at risk of death from respiratory failure. We aimed to determine if continuous positive airway pressure (CPAP), a form of non-invasive ventilation, decreases all-cause mortality in children with undifferentiated respiratory distress in Ghana. This open-label, cluster, crossover trial was done in two Ghanaian non-tertiary hospitals where invasive mechanical ventilation is not routinely available. Eligible participants were children aged from 1 month to 5 years with a respiratory rate of more than 50 breaths per min in children 1-12 months old, or more than 40 breaths per min in children older than 12 months, and use of accessory muscles or nasal flaring. CPAP machines were allocated to one hospital during each study block, while the other hospital served as the control site. The initial intervention site was randomly chosen using a coin toss. 5 cm of water pressure was delivered via CPAP nasal prongs. The primary outcome measure was all-cause mortality rate at 2 weeks after enrolment in patients for whom data were available after 2 weeks. We also did post-hoc regression analysis and subgroup analysis of children by malaria status, oxygen saturation, and age. This study is registered with ClinicalTrials.gov, number NCT01839474. Between Jan 20, 2014, and Dec 5, 2015, 2200 children were enrolled: 1025 at the intervention site and 1175 at the control site. Final analysis included 1021 patients in the CPAP group and 1160 patients in the control group. 2 weeks after enrolment, 26 (3%) of 1021 patients in the CPAP group, and 44 (4%) of 1160 patients in the control group, had died (relative risk [RR] of mortality 0·67, 95% CI 0·42-1·08; p=0·11). In children younger than 1 year, all-cause mortality was ten (3%) of 374 patients in the CPAP group, and 24 (7%) of 359 patients in the control group (RR 0·40, 0·19-0·82; p=0·01). After adjustment for study site

  15. Residual sleepiness in sleep apnea patients treated by continuous positive airway pressure.

    PubMed

    Gasa, Merce; Tamisier, Renaud; Launois, Sandrine H; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Levy, Patrick; Pepin, Jean-Louis

    2013-08-01

    Hypoxic brain damage might explain persistent sleepiness in some continuous positive airway pressure-compliant obstructive sleep apnea called residual excessive sleepiness. Although continuous positive airway pressure may not be fully efficient in treating this symptom, wake-promoting drug prescription in residual excessive sleepiness is no longer allowed by the European Medicines Agency. The aim of this study is to describe residual excessive sleepiness phenotypes in a large prospective sample of patients with obstructive sleep apnea. Residual excessive sleepiness was defined by an Epworth Sleepiness Scale score ≥ 11. Eligible patients from the French National Sleep Registry attending follow-up continuous positive airway pressure visits numbered 1047. Patients using continuous positive airway pressure < 3 h (n = 275), with residual apnea-hypopnea index > 15 h⁻¹ (n = 31) or with major depression were excluded (n = 150). Residual excessive sleepiness prevalence in continuous positive airway pressure-treated obstructive sleep apnea was 13% (18% for those with an initial Epworth Sleepiness Scale score > 11), and significantly decreased with continuous positive airway pressure use (9% in ≥ 6 h night⁻¹ continuous positive airway pressure users, P < 0.005). At the time of diagnosis, patients with residual excessive sleepiness had worse subjective appreciation of their disease (general health scale, Epworth Sleepiness Scale and fatigue score), and complained more frequently of continuous positive airway pressure side-effects. Residual excessive sleepiness prevalence was lower in severe obstructive sleep apnea than in moderate obstructive sleep apnea (11% when AHI > 30 h⁻¹ versus 18% when AHI 15-30, P < 0.005). There was no relationship between residual excessive sleepiness and body mass index, cardiovascular co-morbidities or diabetes. Continuous positive airway pressure improved symptoms in the whole population, but to a lower extent in patients with

  16. Adherence to Continuous Positive Airway Pressure in Existing Users: Self-Efficacy Enhances the Association between Continuous Positive Airway Pressure and Adherence

    PubMed Central

    Dzierzewski, Joseph M.; Wallace, Douglas M.; Wohlgemuth, William K.

    2016-01-01

    Study Objectives: Obstructive sleep apnea-hypopnea syndrome (OSAHS) is a common sleep disorder associated with a myriad of sequelae. OSAHS is effectively treated with continuous positive airway pressure (CPAP) therapy. However, fewer than 50% of patients are compliant with their CPAP therapy prescriptions. The current study sought to explore an integrated, biopsychological approach to CPAP adherence among experienced CPAP users. Methods: We performed a retrospective, cross-sectional analysis of a cohort of veterans with a diagnosis of OSAHS (n = 191) who were prescribed CPAP therapy and returned for adherence download at the Miami VA Sleep Clinic. The relationships between biomedical characteristics (e.g., CPAP pressure, self-reported sleepiness, and change in sleep efficiency) and psychological factors (e.g., self-efficacy beliefs and psychological diagnoses) and objectively measured CPAP use were examined to determine whether psychological factors moderated the relationships between biomedical characteristics and CPAP adherence. Results: Hierarchical regression analyses predicting CPAP adherence (adjusting for time since CPAP prescription, age, education, prescribed CPAP pressure, daytime sleepiness, changes in sleep efficiency with CPAP, and psychiatric conditions) revealed the following: (1) CPAP self-efficacy and CPAP pressure were positively related to adherence, and (2) CPAP self-efficacy moderates the relationship between CPAP pressure and CPAP adherence. Conclusions: There was no relationship between CPAP pressure and adherence in individuals with low self-efficacy beliefs. However, for individuals with high self-efficacy beliefs, there was a significant positive relationship between CPAP pressure and adherence. Self-efficacy beliefs appear to be a prime target for focused interventions aimed at improving CPAP adherence among those individuals with higher pressure prescriptions. Citation: Dzierzewski JM, Wallace DM, Wohlgemuth WK. Adherence to continuous

  17. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    PubMed

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P < 0.001) in 51 patients. The cohort study of 100 patients showed that AHI was satisfactorily decreased after CPAP treatment using a pressure derived from manual titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P < 0.001). The results suggest that automatic titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  18. The Effect of Nasal Obstruction after Different Nasal Surgeries Using Acoustic Rhinometry and Nasal Obstruction Symptom Evaluation Scale

    PubMed Central

    Kahraman, Erkan; Cil, Yakup; Incesulu, Armagan

    2016-01-01

    BACKGROUND The efficiency of nasal surgeries can be determined by objective or subjective methods. We have assessed the effect of nasal obstruction after different nasal surgeries using Acoustic Rhinometry (AR) and Nasal Obstruction Symptom Evaluation (NOSE) Scale. METHODS Between May 2011 and May 2012, 40 young adult patients and 10 healthy volunteers as control group who referred to Otorhinolaryngology Clinic in Eskisehir Military Hospital due to nasal obstruction were enrolled. Depending on operation, patients were divided into four equal groups. Group 1: Septoplasty, Group 2: Septoplasty with sprader graft, Group 3: Septorinoplasty and Group 4: Septorhinoplasty with spreader graft. The patients completed NOSE scale, 1 week before and 1 month after the surgery and AR measurements. RESULTS There were a significant improvement in mean NOSE scores of patients and statistical difference was found between pre and post-operational values for each group. There was a statistically significant change of the mean minimal cross section areas (MCA) of the deviated side of nasal passages measured by AR between pre and postoperative period. CONCLUSION In patients with nasal obstruction, functional nasal surgeries which were performed after appropriate medical examination and with right operation methods had a positive impact on quality of life and patient satisfaction. We observed that nasal findings were correlated with NOSE scores and MCA values. So, we suggest that NOSE scale and AR to be used for evaluation of the efficiency of functional nasal surgeries. PMID:27853686

  19. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3900 Nasal dilator. (a) Identification. A...

  20. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3900 Nasal dilator. (a) Identification. A...

  1. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3900 Nasal dilator. (a) Identification. A...

  2. Oxidative stress mediated arterial dysfunction in patients with obstructive sleep apnoea and the effect of continuous positive airway pressure treatment

    PubMed Central

    2012-01-01

    Background Several studies suggest an increase of oxidative stress and a reduction of endothelial function in obstructive sleep apnoea syndrome (OSAS). We assessed the association between OSAS, endothelial dysfunction and oxidative stress. Further aim was to evaluate the effect of nasal continuous positive airway pressure (nCPAP) on oxidative stress and arterial dysfunction. Methods We studied 138 consecutive patients with heavy snoring and possible OSAS. Patients underwent unattended overnight home polysomnography. Ten patients with severe OSAS were revaluated after 6 months of nCPAP therapy. To assess oxidative stress in vivo, we measured urinary 8-iso-PGF2α and serum levels of soluble NOX2-derived peptide (sNOX2-dp). Serum levels of nitrite/nitrate (NOx) were also determined. Flow-mediated brachial artery dilation (FMD) was measured to asses endothelial function. Results Patients with severe OSAS had higher urinary 8-iso-PGF2α (p<0.001) and serum NOX2 and lower NOx. A negative association was observed between FMD and OSA severity. Apnea/hypopnea index was significantly correlated with the indices of central obesity and with urinary 8-isoprostanes (r=0.298, p<0.001). The metabolic syndrome (t=-4.63, p<0.001) and urinary 8-isoprostanes (t=-2.02, p<0.05) were the only independent predictors of FMD. After 6-months nCPAP treatment, a significant decrease of serum NOX2, (p<0.005) and urinary 8-iso-PGF2α (p<0.01) was observed, while serum NOx showed only a minor increase. A statistically significant increase of FMD was observed (from 3.6% to 7.0%). Conclusions The results of our study indicate that patients with OSAS and cardiometabolic comorbidities have increased oxidative stress and arterial dysfunction that are partially reversed by nCPAP treatment. PMID:22824065

  3. Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial.

    PubMed

    Benes, Jan; Simanova, Alena; Tovarnicka, Tereza; Sevcikova, Silvie; Kletecka, Jakub; Zatloukal, Jan; Pradl, Richard; Chytra, Ivan; Kasal, Eduard

    2015-02-01

    Intermittent blood pressure (BP) monitoring is the standard-of-care during low and intermediate risk anaesthesia, yet it could lead to delayed recognition of BP fluctuations. Perioperative hypotension is known to be associated with postoperative complications. Continuous, non-invasive methods for BP monitoring have been developed recently. We have tested a novel non-invasive, continuous monitor (using the volume clamp method) to assist with maintaining BP in safe ranges for patients undergoing surgery in a beach chair position. Forty adult patients undergoing thyroid gland surgery in an upright position were included in this prospective randomised controlled trial. Patients were equally allocated to the group with continuous monitoring of BP using the CNAP® Monitor and to the control group managed using an intermittent oscillometric BP cuff. The absolute and proportional time spent outside the range of ±20% of the target BP along with other hemodynamic and clinical parameters were evaluated. The continuous monitoring decreased the anaesthesia time spent below -20% pressure range [absolute: 12 min (4-20) vs. 27 min (16-34); p=0.001; relative to procedure length: 14% (7-20) vs. 33.5% (17.5-53); p=0.003]. No significant differences were observed in postoperative morbidity or in hospital length of stay. Continuous non-invasive BP monitoring via the CNAP® Monitor allows for better BP management in patients undergoing surgery in a beach chair position. In our randomised trial the time spent in hypotension was significantly shorter using continuous monitoring.

  4. Effect of bi-level positive airway pressure (BiPAP) nasal ventilation on the postoperative pulmonary restrictive syndrome in obese patients undergoing gastroplasty.

    PubMed

    Joris, J L; Sottiaux, T M; Chiche, J D; Desaive, C J; Lamy, M L

    1997-03-01

    Upper abdominal surgery results in a postoperative restrictive pulmonary syndrome. Bi-level positive airway pressure (BiPAP System; Respironics Inc; Murrysville, Pa), which combines pressure support ventilation and positive end-expiratory pressure via a nasal mask, could allow alveolar recruitment during inspiration and prevent expiratory alveolar collapse, and therefore limit the postoperative pulmonary restrictive syndrome. This study investigated the effect of BiPAP on postoperative pulmonary function in obese patients after gastroplasty. Prospective controlled randomized study. GI surgical ward in a university hospital. Thirty-three morbidly obese patients scheduled for gastroplasty were studied. The patients were assigned to one of three techniques of ventilatory support during the first 24 h postoperatively: O2 via a face mask, BiPAP System 8/4, with inspiratory and expiratory positive airway pressure set at 8 and 4 cm H2O, respectively, or BiPAP System 12/4 set at 12 and 4 cm H2O. Pulmonary function (FVC, FEV1, and peak expiratory flow rate [PEFR]) were measured the day before surgery, 24 h after surgery, and on days 2 and 3. Oxygen saturation by pulse oximeter (SpO2) was also recorded during room air breathing. Three patients were excluded. After surgery, FVC, FEV1, PEFR, and SpO2 significantly decreased in the three groups. On day 1, FVC and FEV1 were significantly improved in the group BiPAP System 12/4, as compared with no BiPAP; SpO2 was also significantly improved. After removal of BiPAP System 12/4, these benefits were maintained, allowing faster recovery of pulmonary function. No significant effects were observed on PEFR. BiPAP System 8/4 had no significant effect on the postoperative pulmonary restrictive syndrome. Prophylactic use of BiPAP System 12/4 during the first 24 h postoperatively significantly reduces pulmonary dysfunction after gastroplasty in obese patients and accelerates reestablishment of preoperative pulmonary function.

  5. Bilateral cleft lip nasal deformity

    PubMed Central

    Singh, Arun Kumar; Nandini, R.

    2009-01-01

    Bilateral cleft lip nose deformity is a multi-factorial and complex deformity which tends to aggravate with growth of the child, if not attended surgically. The goals of primary bilateral cleft lip nose surgery are, closure of the nasal floor and sill, lengthening of the columella, repositioning of the alar base, achieving nasal tip projection, repositioning of the lower lateral cartilages, and reorienting the nares from horizontal to oblique position. The multiplicity of procedures in the literature for correction of this deformity alludes to the fact that no single procedure is entirely effective. The timing for surgical intervention and its extent varies considerably. Early surgery on cartilage may adversely affect growth and development; at the same time, allowing the cartilage to grow in an abnormal position and contributing to aggravation of deformity. Some surgeons advocate correction of deformity at an early age. However, others like the cartilages to grow and mature before going in for surgery. With peer pressure also becoming an important consideration during the teens, the current trend is towards early intervention. There is no unanimity in the extent of nasal dissection to be done at the time of primary lip repair. While many perform limited nasal dissection for the fear of growth retardation, others opt for full cartilage correction at the time of primary surgery itself. The value of naso-alveolar moulding (NAM) too is not universally accepted and has now more opponents than proponents. Also most centres in the developing world have neither the personnel nor the facilities for the same. The secondary cleft nasal deformity is variable and is affected by the extent of the original abnormality, any prior surgeries performed and alteration due to nasal growth. This article reviews the currently popular methods for correction of nasal deformity associated with bilateral cleft lip, it's management both at the time of cleft lip repair and also secondarily

  6. Nasalance, nasality, voice, and articulation after uvulopalatopharyngoplasty.

    PubMed

    Van Lierde, Kristiane M; Van Borsel, John; Moerman, Mieke; Van Cauwenberge, Paul

    2002-05-01

    The main purpose of the study was to determine the impact of uvulopalatopharyngoplasty (UPPP) on nasalance and nasality. It was hypothesized that nasalance would change from the presurgical to the postsurgical condition because the surgical protocol involves removal of palatal tissue. An additional objective of the study was to provide objective and subjective data about changes in voice and articulation after UPPP. Because the surgical procedure of UPPP does not involve laryngeal tissue, it was hypothesized that the voice characteristics remain relatively stable. Because of removal of effective velar length, articulation problems of the uvular /R/ can occur in the Dutch language. Prospective study in which 26 men were studied before (1 week before UPPP) and after (3 weeks after UPPP) surgery. The Nasometer was used to obtain nasalance scores. The mirror-fogging test, a perceptual evaluation of each subject's readings, and the Gutzmann and the Bzoch hypernasality tests were used for the assessment of nasality. For the assessment of articulation, a phonetic analysis was performed. Voice assessment included a perceptual rating of the voice and a determination of fundamental frequency. No significant differences were found between the conditions before and after surgery regarding nasalance (except for the vowel /i/), nasality, and voice. Regarding articulation, only 1 patient showed a derhotacized /R/. The findings of the study indicate that UPPP does not have an impact on nasality, voice, and articulation. Regarding nasalance, no significant nasalance change occurred after UPPP, except for the high vowel /i/.

  7. Absolute continuity for operator valued completely positive maps on C∗-algebras

    NASA Astrophysics Data System (ADS)

    Gheondea, Aurelian; Kavruk, Ali Şamil

    2009-02-01

    Motivated by applicability to quantum operations, quantum information, and quantum probability, we investigate the notion of absolute continuity for operator valued completely positive maps on C∗-algebras, previously introduced by Parthasarathy [in Athens Conference on Applied Probability and Time Series Analysis I (Springer-Verlag, Berlin, 1996), pp. 34-54]. We obtain an intrinsic definition of absolute continuity, we show that the Lebesgue decomposition defined by Parthasarathy is the maximal one among all other Lebesgue-type decompositions and that this maximal Lebesgue decomposition does not depend on the jointly dominating completely positive map, we obtain more flexible formulas for calculating the maximal Lebesgue decomposition, and we point out the nonuniqueness of the Lebesgue decomposition as well as a sufficient condition for uniqueness. In addition, we consider Radon-Nikodym derivatives for absolutely continuous completely positive maps that, in general, are unbounded positive self-adjoint operators affiliated to a certain von Neumann algebra, and we obtain a spectral approximation by bounded Radon-Nikodym derivatives. An application to the existence of the infimum of two completely positive maps is indicated, and formulas in terms of Choi's matrices for the Lebesgue decomposition of completely positive maps in matrix algebras are obtained.

  8. Acute Effects of Continuous Positive Air way Pressure on Pulse Pressure in Chronic Heart Failure

    PubMed Central

    Quintão, Mônica; Chermont, Sérgio; Marchese, Luana; Brandão, Lúcia; Bernardez, Sabrina Pereira; Mesquita, Evandro Tinoco; Rocha, Nazareth de Novaes; Nóbrega, Antônio Claudio L.

    2014-01-01

    Background Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. Objective The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Methods Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. Results CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min). Conclusion NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome. PMID:24676373

  9. Acute effects of continuous positive air way pressure on pulse pressure in chronic heart failure.

    PubMed

    Quintão, Mônica; Chermont, Sérgio; Marchese, Luana; Brandão, Lúcia; Bernardez, Sabrina Pereira; Mesquita, Evandro Tinoco; Novaes Rocha, Nazareth de; Nóbrega, Antônio Claudio L

    2014-02-01

    Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60±11 years; BMI 29±5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. CPAP decreased resting heart rate (Pre: 72±9; vs. Post 5 min: 67±10 bpm; p<0.01) and MAP (CPAP: 87±11; vs. control 96±11 mmHg; p<0.05 post 5 min). CPAP decreased PP (CPAP: 47±20 pre to 38±19 mmHg post; vs. control: 42±12 mmHg, pre to 41±18 post p<0.05 post 5 min). NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome.

  10. [Initiation of therapy in the sleep apnea syndrome using continuous positive pressure respiration].

    PubMed

    Sonka, K; Kucerová, O; Hoskovec, P; Nevsímalová, S

    1994-09-26

    Continuous positive airway pressure is the most important therapeutic method of sleep apnea syndrome (SAS). The prerequisite for its initiation is assessment of the optimal positive pressure and adaptation of the patient to this treatment. The basic criterium for assessment of positive pressure is elimination of apnoic intervals. The objective of the present work was to evaluate the optimal positive pressure CPAP according to the continuity of sleep and the appearance of an abnormally long (longer than 30 mins.) episode of REM sleep ("REM rebound"). CPAP was indicated in 13 patients with SAS (12 men, 1 woman), mean age 52.1 +/- 8.8 (SD) years, mean body mass index (BMI) 37.4 +/- 10.5. Severe cases of SAS were involved and/or SAS associated with other diseases (acromegaly-2, hypertension-8, IHD-4, chronic bronchopulmonary obstruction-3, and stroke-1). During one-night polysomnographic monitoring gradually the CPAP pressure was increased. Optimal positive pressure was signalized in addition to indicators of ventilation by uninterrupted sleep and "REM rebound". For treatment equipment of SEFAM Co. was used: 2x Pression+, 7x REM+, 4x REM+Control. Two patients refused CPAP treatment during the adaptation night. Eleven patients accepted CPAP treatment. The mean positive pressure value was 10.4 +/- 3.0 mbar. Assessment based on "REM rebound" was possible in six patients and based on continuity in 5 patients. Later pressure changes were called for in one patient (during adaptation he did not have "REM rebound"). Assessment of the optimal CPAP pressure as the lowest positive pressure compatible with regular breathing, as well as stabilized normal oxygen saturation of peripheral blood, continuous sleep and possibly "rebound" REM sleep proved useful.

  11. Quilting sutures for nasal septum.

    PubMed

    Hari, C; Marnane, C; Wormald, P J

    2008-05-01

    Suturing of the nasal septum after septal surgery is a commonly performed procedure designed to prevent complications such as septal haematoma and bleeding. It is also useful for closing any inadvertent tears of the septal mucosa and providing additional support for the cartilage pieces retained in septoplasty. In addition, the suture can be placed through the middle turbinates, stabilising them during the healing process. Placing knots for interrupted sutures in the posterior and middle part of the nasal septum can be technically difficult. We describe a continuous suturing technique for approximating the mucosal flaps following septal surgery.

  12. Continuous positive airway pressure-associated cutaneous amoebiasis in an immunosuppressed patient.

    PubMed

    Sells, R E; Chen, C A; Wong, M T; Zimarowski, M J; Kirby, J E; Joyce, R M; Wu, P A

    2016-03-01

    Organisms of the genus Acanthamoeba are environmentally ubiquitous and colonizers of the oral mucosa in humans. While largely asymptomatic in healthy persons, Acanthamoeba infection can cause disseminated disease with poor prognosis in immunosuppressed populations. Here we report a unique case of cutaneous amoebiasis associated with continuous positive airway pressure use in an immunosuppressed patient. © 2015 British Association of Dermatologists.

  13. Use of continuous positive airway pressure in the acute management of laryngeal paralysis in a cat.

    PubMed

    Ticehurst, K; Zaki, S; Hunt, G B; Macpherson, C; Nicholson, H

    2008-10-01

    Continuous positive airway pressure (CPAP) has been is used widely in humans to manage obstructive sleep apnoea syndrome, but it has not been widely used in animals. A brachycephalic cat, with previously undiagnosed laryngeal paralysis, that developed acute upper respiratory tract obstruction on recovery from anaesthesia, is presented. The condition was managed by CPAP, delivered via a facial mask.

  14. Motivational Interviewing (MINT) Improves Continuous Positive Airway Pressure (CPAP) Acceptance and Adherence: A Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Olsen, Sara; Smith, Simon S.; Oei, Tian P. S.; Douglas, James

    2012-01-01

    Objective: Adherence to continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA) is poor. We assessed the effectiveness of a motivational interviewing intervention (motivational interview nurse therapy [MINT]) in addition to best practice standard care to improve acceptance and adherence to CPAP therapy in people with…

  15. Motivational Interviewing (MINT) Improves Continuous Positive Airway Pressure (CPAP) Acceptance and Adherence: A Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Olsen, Sara; Smith, Simon S.; Oei, Tian P. S.; Douglas, James

    2012-01-01

    Objective: Adherence to continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA) is poor. We assessed the effectiveness of a motivational interviewing intervention (motivational interview nurse therapy [MINT]) in addition to best practice standard care to improve acceptance and adherence to CPAP therapy in people with…

  16. Continuous Positive Airway Pressure Treatment of Sleepy Patients with Milder Obstructive Sleep Apnea

    PubMed Central

    Mancini, Cristina; Maislin, Greg; Cater, Jacqueline; Staley, Bethany; Landis, J. Richard; Ferguson, Kathleen A.; George, Charles F. P.; Schulman, David A.; Greenberg, Harly; Rapoport, David M.; Walsleben, Joyce A.; Lee-Chiong, Teofilo; Gurubhagavatula, Indira; Kuna, Samuel T.

    2012-01-01

    Rationale: Twenty-eight percent of people with mild to moderate obstructive sleep apnea experience daytime sleepiness, which interferes with daily functioning. It remains unclear whether treatment with continuous positive airway pressure improves daytime function in these patients. Objectives: To evaluate the efficacy of continuous positive airway pressure treatment to improve functional status in sleepy patients with mild and moderate obstructive sleep apnea. Methods: Patients with self-reported daytime sleepiness (Epworth Sleepiness Scale score >10) and an apnea-hypopnea index with 3% desaturation and from 5 to 30 events per hour were randomized to 8 weeks of active or sham continuous positive airway pressure treatment. After the 8-week intervention, participants in the sham arm received 8 weeks of active continuous positive airway pressure treatment. Measurements and Main Results: The Total score on the Functional Outcomes of Sleep Questionnaire was the primary outcome measure. The adjusted mean change in the Total score after the first 8-week intervention was 0.89 for the active group (n = 113) and −0.06 for the placebo group (n = 110) (P = 0.006). The group difference in mean change corresponded to an effect size of 0.41 (95% confidence interval, 0.14–0.67). The mean (SD) improvement in Functional Outcomes of Sleep Questionnaire Total score from the beginning to the end of the crossover phase (n = 91) was 1.73 ± 2.50 (t[90] = 6.59; P < 0.00001) with an effect size of 0.69. Conclusions: Continuous positive airway pressure treatment improves the functional outcome of sleepy patients with mild and moderate obstructive sleep apnea. Clinical trial registered with www.clinicaltrials.gov (NCT 00127348). PMID:22837377

  17. Deprojecting the nasal profile.

    PubMed

    Papel, I D; Mabrie, D C

    1999-02-01

    The nose is the most prominent aesthetic feature of the facial profile. Nasal length, tip rotation, and tip projection are integral aspects in analysis of the nasal profile. In most rhinoplasties the surgeon has the difficult task of increasing or maintaining tip projection of an underprojected or normally projected nasal tip. Less commonly, the rhinoplastic surgeon is presented with an overprojected nasal tip, and efforts are focused on deprojecting the nasal profile. In this article, the authors present a discussion of the overprojected tip, elucidating strategies of analysis, etiologies, and management of the nasal profile and give clinical examples.

  18. Nasal Injuries in Sports.

    PubMed

    Marston, Alexander P; O'Brien, Erin K; Hamilton, Grant S

    2017-04-01

    Nasal trauma is a common consequence of athletic competition. The nasal bones are the most commonly fractured facial bone and are particularly at risk during sports participation. Acute management of trauma to the nose includes thorough evaluation of all injuries and may require immediate management for repair of facial lacerations, epistaxis control, or septal hematoma drainage. Nasal fractures can often be addressed with closed reduction techniques; however, in the setting of complex nasal trauma, an open approach may be indicated. Using appropriate treatment techniques, posttraumatic nasal sequelae can be minimized; most patients report satisfactory long-term nasal form and function.

  19. Distributed Position-Based Consensus of Second-Order Multiagent Systems With Continuous/Intermittent Communication.

    PubMed

    Song, Qiang; Liu, Fang; Wen, Guanghui; Cao, Jinde; Yang, Xinsong

    2017-04-24

    This paper considers the position-based consensus in a network of agents with double-integrator dynamics and directed topology. Two types of distributed observer algorithms are proposed to solve the consensus problem by utilizing continuous and intermittent position measurements, respectively, where each observer does not interact with any other observers. For the case of continuous communication between network agents, some convergence conditions are derived for reaching consensus in the network with a single constant delay or multiple time-varying delays on the basis of the eigenvalue analysis and the descriptor method. When the network agents can only obtain intermittent position data from local neighbors at discrete time instants, the consensus in the network without time delay or with nonuniform delays is investigated by using the Wirtinger's inequality and the delayed-input approach. Numerical examples are given to illustrate the theoretical analysis.

  20. Bubble continuous positive airway pressure for children with severe pneumonia and hypoxaemia in Bangladesh: an open, randomised controlled trial.

    PubMed

    Chisti, Mohammod J; Salam, Mohammed A; Smith, Jonathan H; Ahmed, Tahmeed; Pietroni, Mark A C; Shahunja, K M; Shahid, Abu S M S B; Faruque, Abu S G; Ashraf, Hasan; Bardhan, Pradip K; Sharifuzzaman; Graham, Stephen M; Duke, Trevor

    2015-09-12

    In developing countries, mortality in children with very severe pneumonia is high, even with the provision of appropriate antibiotics, standard oxygen therapy, and other supportive care. We assessed whether oxygen therapy delivered by bubble continuous positive airway pressure (CPAP) improved outcomes compared with standard low-flow and high-flow oxygen therapies. This open, randomised, controlled trial took place in Dhaka Hospital of the International Centre for Diarrhoeal Disease Research, Bangladesh. We randomly assigned children younger than 5 years with severe pneumonia and hypoxaemia to receive oxygen therapy by either bubble CPAP (5 L/min starting at a CPAP level of 5 cm H2O), standard low-flow nasal cannula (2 L/min), or high-flow nasal cannula (2 L/kg per min up to the maximum of 12 L/min). Randomisation was done with use of the permuted block methods (block size of 15 patients) and Fisher and Yates tables of random permutations. The primary outcome was treatment failure (ie, clinical failure, intubation and mechanical ventilation, death, or termination of hospital stay against medical advice) after more than 1 h of treatment. Primary and safety analyses were by intention to treat. We did two interim analyses and stopped the trial after the second interim analysis on Aug 3, 2013, as directed by the data safety and monitoring board. This trial is registered at ClinicalTrials.gov, number NCT01396759. Between Aug 4, 2011, and July 17, 2013, 225 eligible children were recruited. We randomly allocated 79 (35%) children to receive oxygen therapy by bubble CPAP, 67 (30%) to low-flow oxygen therapy, and 79 (35%) to high-flow oxygen therapy. Treatment failed for 31 (14%) children, of whom five (6%) had received bubble CPAP, 16 (24%) had received low-flow oxygen therapy, and ten (13%) had received high-flow oxygen therapy. Significantly fewer children in the bubble CPAP group had treatment failure than in the low-flow oxygen therapy group (relative risk [RR] 0·27

  1. Continuous Indoor Positioning Fusing WiFi, Smartphone Sensors and Landmarks

    PubMed Central

    Deng, Zhi-An; Wang, Guofeng; Qin, Danyang; Na, Zhenyu; Cui, Yang; Chen, Juan

    2016-01-01

    To exploit the complementary strengths of WiFi positioning, pedestrian dead reckoning (PDR), and landmarks, we propose a novel fusion approach based on an extended Kalman filter (EKF). For WiFi positioning, unlike previous fusion approaches setting measurement noise parameters empirically, we deploy a kernel density estimation-based model to adaptively measure the related measurement noise statistics. Furthermore, a trusted area of WiFi positioning defined by fusion results of previous step and WiFi signal outlier detection are exploited to reduce computational cost and improve WiFi positioning accuracy. For PDR, we integrate a gyroscope, an accelerometer, and a magnetometer to determine the user heading based on another EKF model. To reduce accumulation error of PDR and enable continuous indoor positioning, not only the positioning results but also the heading estimations are recalibrated by indoor landmarks. Experimental results in a realistic indoor environment show that the proposed fusion approach achieves substantial positioning accuracy improvement than individual positioning approaches including PDR and WiFi positioning. PMID:27608019

  2. Continuous Indoor Positioning Fusing WiFi, Smartphone Sensors and Landmarks.

    PubMed

    Deng, Zhi-An; Wang, Guofeng; Qin, Danyang; Na, Zhenyu; Cui, Yang; Chen, Juan

    2016-09-05

    To exploit the complementary strengths of WiFi positioning, pedestrian dead reckoning (PDR), and landmarks, we propose a novel fusion approach based on an extended Kalman filter (EKF). For WiFi positioning, unlike previous fusion approaches setting measurement noise parameters empirically, we deploy a kernel density estimation-based model to adaptively measure the related measurement noise statistics. Furthermore, a trusted area of WiFi positioning defined by fusion results of previous step and WiFi signal outlier detection are exploited to reduce computational cost and improve WiFi positioning accuracy. For PDR, we integrate a gyroscope, an accelerometer, and a magnetometer to determine the user heading based on another EKF model. To reduce accumulation error of PDR and enable continuous indoor positioning, not only the positioning results but also the heading estimations are recalibrated by indoor landmarks. Experimental results in a realistic indoor environment show that the proposed fusion approach achieves substantial positioning accuracy improvement than individual positioning approaches including PDR and WiFi positioning.

  3. Tension pneumocephalus induced by high-flow nasal cannula ventilation in a neonate.

    PubMed

    Iglesias-Deus, Alicia; Pérez-Muñuzuri, Alejandro; López-Suárez, Olalla; Crespo, Pilar; Couce, Maria-Luz

    2017-03-01

    The use of high-flow nasal cannula (HFNC) therapy as respiratory support for preterm infants has increased rapidly worldwide. The evidence available for the use of HFNC is as an alternative to nasal continuous positive airway pressure (CPAP) and in particular to prevent postextubation failure. We report a case of tension pneumocephalus in a preterm infant as a complication during HFNC ventilation. Significant neurological impairment was detected and support was eventually withdrawn. Few cases of pneumocephalus as a complication of positive airway pressure have been reported in the neonatal period, and they all have been related to CPAP. This report reinforces the need to be aware of this rare but possible complication during HFNC therapy, as timely diagnosis and treatment can prevent neurological sequelae. We also stress the importance of paying close attention to flow rate, nasal cannula size and insertion, and mouth position, and of regularly checking insertion depth.

  4. Changes in lung volume and upper airway using MRI during application of nasal expiratory positive airway pressure in patients with sleep-disordered breathing.

    PubMed

    Braga, C W; Chen, Q; Burschtin, O E; Rapoport, D M; Ayappa, I

    2011-11-01

    Nasal expiratory positive airway pressure (nEPAP) delivered with a disposable device (Provent, Ventus Medical) has been shown to improve sleep-disordered breathing (SDB) in some subjects. Possible mechanisms of action are 1) increased functional residual capacity (FRC), producing tracheal traction and reducing upper airway (UA) collapsibility, and 2) passive dilatation of the airway by the expiratory pressure, carrying over into inspiration. Using MRI, we estimated change in FRC and ventilation, as well as UA cross-sectional area (CSA), in awake patients breathing on and off the nEPAP device. Ten patients with SDB underwent nocturnal polysomnography and MRI with and without nEPAP. Simultaneous images of the lung and UA were obtained at 6 images/s. Image sequences were obtained during mouth and nose breathing with and without the nEPAP device. The nEPAP device produced an end-expiratory pressure of 4-17 cmH(2)O. End-tidal Pco(2) rose from 39.7 ± 5.3 to 47.1 ± 6.0 Torr (P < 0.01). Lung volume changes were estimated from sagittal MRI of the right lung. Changes in UA CSA were calculated from transverse MRI at the level of the pharynx above the epiglottis. FRC determined by MRI was well correlated to FRC determined by N(2) washout (r = 0.76, P = 0.03). nEPAP resulted in a consistent increase in FRC (46 ± 29%, P < 0.001) and decrease in ventilation (50 ± 15%, P < 0.001), with no change in respiratory frequency. UA CSA at end expiration showed a trend to increase. During wakefulness, nEPAP caused significant hyperinflation, consistent with an increase in tracheal traction and a decrease in UA collapsibility. Direct imaging effects on the UA were less consistent, but there was a trend to dilatation. Finally, we showed significant hypoventilation and rise in Pco(2) during use of the nEPAP device during wakefulness and sleep. Thus, at least three mechanisms of action have the potential to contribute to the therapeutic effect of nEPAP on SDB.

  5. The Effects of Sleep Continuity Disruption on Positive Mood and Sleep Architecture in Healthy Adults.

    PubMed

    Finan, Patrick H; Quartana, Phillip J; Smith, Michael T

    2015-11-01

    The purpose of this study was to test an experimental model of the effects of sleep continuity disturbance on sleep architecture and positive mood in order to better understand the mechanisms linking insomnia and depression. Participants were randomized to receive 3 consecutive nights of sleep continuity disruption via forced nocturnal awakenings (FA, n = 21), or one of two control conditions: restricted sleep opportunity (RSO, n = 17) or uninterrupted sleep (US, n = 24). The study was set in an inpatient clinical research suite. Healthy, good-sleeping men and women were included. Polysomnography was used to measure sleep architecture, and mood was assessed via self-report each day. Compared to restricted sleep opportunity controls, forced awakenings subjects had significantly less slow wave sleep (P < 0.05) after the first night of sleep deprivation, and significantly lower positive mood (P < 0.05) after the second night of sleep deprivation. The differential change in slow wave sleep statistically mediated the observed group differences in positive mood (P = 0.002). To our knowledge, this is the first human experimental study to demonstrate that, despite comparable reductions in total sleep time, partial sleep loss from sleep continuity disruption is more detrimental to positive mood than partial sleep loss from delaying bedtime, even when controlling for concomitant increases in negative mood. With these findings, we provide temporal evidence in support of a putative biologic mechanism (slow wave sleep deficit) that could help explain the strong comorbidity between insomnia and depression. © 2015 Associated Professional Sleep Societies, LLC.

  6. The Effects of Sleep Continuity Disruption on Positive Mood and Sleep Architecture in Healthy Adults

    PubMed Central

    Finan, Patrick H.; Quartana, Phillip J.; Smith, Michael T.

    2015-01-01

    Objective: The purpose of this study was to test an experimental model of the effects of sleep continuity disturbance on sleep architecture and positive mood in order to better understand the mechanisms linking insomnia and depression. Design: Participants were randomized to receive 3 consecutive nights of sleep continuity disruption via forced nocturnal awakenings (FA, n = 21), or one of two control conditions: restricted sleep opportunity (RSO, n = 17) or uninterrupted sleep (US, n = 24). Setting: The study was set in an inpatient clinical research suite. Participants: Healthy, good-sleeping men and women were included. Measurement and Results: Polysomnography was used to measure sleep architecture, and mood was assessed via self-report each day. Compared to restricted sleep opportunity controls, forced awakenings subjects had significantly less slow wave sleep (P < 0.05) after the first night of sleep deprivation, and significantly lower positive mood (P < 0.05) after the second night of sleep deprivation. The differential change in slow wave sleep statistically mediated the observed group differences in positive mood (P = 0.002). Conclusions: To our knowledge, this is the first human experimental study to demonstrate that, despite comparable reductions in total sleep time, partial sleep loss from sleep continuity disruption is more detrimental to positive mood than partial sleep loss from delaying bedtime, even when controlling for concomitant increases in negative mood. With these findings, we provide temporal evidence in support of a putative biologic mechanism (slow wave sleep deficit) that could help explain the strong comorbidity between insomnia and depression. Citation: Finan PH, Quartana PJ, Smith MT. The effects of sleep continuity disruption on positive mood and sleep architecture in healthy adults. SLEEP 2015;38(11):1735–1742. PMID:26085289

  7. Efficacy of continuous positive airway pressure treatment on 5-year survival in patients with ischaemic stroke and obstructive sleep apnea: a randomized controlled trial.

    PubMed

    Parra, Olga; Sánchez-Armengol, Ángeles; Capote, Francisco; Bonnin, Marc; Arboix, Adrià; Campos-Rodríguez, Francisco; Pérez-Ronchel, José; Durán-Cantolla, Joaquín; Martínez-Null, Cristina; de la Peña, Mónica; Jiménez, Maria Carmen; Masa, Fernando; Casadon, Ignacio; Alonso, Maria Luz; Macarrón, José L

    2015-02-01

    The main purpose of the present analysis is to assess the influence of introducing early nasal continuous positive airway pressure (nCPAP) treatment on cardiovascular recurrences and mortality in patients with a first-ever ischaemic stroke and moderate-severe obstructive sleep apnea (OSA) with an apnea-hypopnea index (AHI) ≥20 events h(-1) during a 5-year follow-up. Patients received conventional treatment for stroke and were assigned randomly to the nCPAP group (n = 71) or the control group (n = 69). Cardiovascular events and mortality were registered for all patients. Survival and cardiovascular event-free survival analysis were performed after 5-year follow-up using the Kaplan-Meier test. Patients in the nCPAP group had significantly higher cardiovascular survival than the control group (100 versus 89.9%, log-rank test 5.887; P = 0.015) However, and also despite a positive tendency, there were no significant differences in the cardiovascular event-free survival at 68 months between the nCPAP and control groups (89.5 versus 75.4%, log-rank test 3.565; P = 0.059). Early nCPAP therapy has a positive effect on long-term survival in ischaemic stroke patients and moderate-severe OSA.

  8. Sleep continuity is positively correlated with sleep duration in laboratory nighttime sleep recordings.

    PubMed

    Kishi, Akifumi; Van Dongen, Hans P A; Natelson, Benjamin H; Bender, Amy M; Palombini, Luciana O; Bittencourt, Lia; Tufik, Sergio; Ayappa, Indu; Rapoport, David M

    2017-01-01

    Sleep duration varies widely across individuals and appears to be trait-like. Differences in the stability of underlying sleep processes may underlie this phenomenon. To investigate underlying mechanisms, we examined the relationship between sleep duration and sleep continuity in baseline polysomnography (PSG) recordings from three independently collected datasets: 1) 134 healthy controls (ages 37 ± 13 years) from the São Paulo Epidemiologic Sleep Study, who spent one night in a sleep laboratory, 2) 21 obstructive sleep apnea (OSA) patients who were treated with continuous positive airway pressure for at least 2 months (45 ± 12 years, respiratory disturbance index <15), who spent one night in a sleep laboratory with previous experience of multiple PSG studies, and 3) 62 healthy controls (28 ± 6 years) who, as part of larger experiments, spent 2 consecutive nights in a sleep laboratory. For each dataset, we used total sleep time (TST) to separate subjects into those with shorter sleep (S-TST) and those with longer sleep (L-TST). In all three datasets, survival curves of continuous sleep segments showed greater sleep continuity in L-TST than in S-TST. Correlation analyses with TST as a continuous variable corroborated the results; and the results also held true after controlling for age. There were no significant differences in baseline waking performance and sleepiness between S-TST and L-TST. In conclusion, in both healthy controls and treated OSA patients, sleep continuity was positively correlated with sleep duration. These findings suggest that S-TST may differ from L-TST in processes underlying sleep continuity, shedding new light on mechanisms underlying individual differences in sleep duration.

  9. Sleep continuity is positively correlated with sleep duration in laboratory nighttime sleep recordings

    PubMed Central

    Van Dongen, Hans P. A.; Natelson, Benjamin H.; Bender, Amy M.; Palombini, Luciana O.; Bittencourt, Lia; Tufik, Sergio; Ayappa, Indu; Rapoport, David M.

    2017-01-01

    Sleep duration varies widely across individuals and appears to be trait-like. Differences in the stability of underlying sleep processes may underlie this phenomenon. To investigate underlying mechanisms, we examined the relationship between sleep duration and sleep continuity in baseline polysomnography (PSG) recordings from three independently collected datasets: 1) 134 healthy controls (ages 37 ± 13 years) from the São Paulo Epidemiologic Sleep Study, who spent one night in a sleep laboratory, 2) 21 obstructive sleep apnea (OSA) patients who were treated with continuous positive airway pressure for at least 2 months (45 ± 12 years, respiratory disturbance index <15), who spent one night in a sleep laboratory with previous experience of multiple PSG studies, and 3) 62 healthy controls (28 ± 6 years) who, as part of larger experiments, spent 2 consecutive nights in a sleep laboratory. For each dataset, we used total sleep time (TST) to separate subjects into those with shorter sleep (S-TST) and those with longer sleep (L-TST). In all three datasets, survival curves of continuous sleep segments showed greater sleep continuity in L-TST than in S-TST. Correlation analyses with TST as a continuous variable corroborated the results; and the results also held true after controlling for age. There were no significant differences in baseline waking performance and sleepiness between S-TST and L-TST. In conclusion, in both healthy controls and treated OSA patients, sleep continuity was positively correlated with sleep duration. These findings suggest that S-TST may differ from L-TST in processes underlying sleep continuity, shedding new light on mechanisms underlying individual differences in sleep duration. PMID:28394943

  10. Beclomethasone Nasal Spray

    MedlinePlus

    ... the lining of the nose) after nasal polyp removal surgery. Beclomethasone nasal spray should not be used ... room temperature and away from excess heat and moisture (not in the bathroom).Unneeded medications should be ...

  11. Triamcinolone Nasal Spray

    MedlinePlus

    ... itchy nose and itchy, watery eyes caused by hay fever or other allergies. Triamcinolone nasal spray should not ... germs.Triamcinolone nasal spray controls the symptoms of hay fever and allergies but does not cure these conditions. ...

  12. Evaluation of the add-on NOWAPI® medical device for remote monitoring of compliance to Continuous Positive Airway Pressure and treatment efficacy in obstructive sleep apnea.

    PubMed

    Leger, Damien; Elbaz, Maxime; Piednoir, Benoît; Carron, Amélie; Texereau, Joëlle

    2016-02-27

    Optimizing the measurement of Continuous Positive Airway Pressure (CPAP) compliance and treatment efficacy is paramount for patients with obstructive sleep apnea syndrome (OSAS). Compliance knowledge is currently based on data coming from CPAP machines; however algorithms and measured parameters vary from one machine to another. This study was conducted to clinically evaluate a novel device, NOWAPI(®), designed to assess compliance remotely in conjunction with any CPAP machine. NOWAPI(®) was tested against polygraphy, the gold standard for the measurement of CPAP treatment duration and residual apnea-hypopnea index (AHI). Single group assignment, open label, non-randomized. Sleep laboratory setting. 22 adult patients with OSAS treated by CPAP were included. Recordings were performed during one night while the patient was treated with his/her usual CPAP and interface. NOWAPI(®) data were collected electronically and compared to data acquisition and visual scoring using an EMBLETTA(®) GOLD polygraph. Statistics were only descriptive. Recordings were performed with six different CPAP machines and three different interfaces (full facemask, nasal pillow, nasal mask). The median [Q1; Q3] absolute difference in CPAP treatment duration between NOWAPI(®) and polygraphy was of 1.0 min [0.0; 12.0], corresponding to a relative difference of 0.21 % [0.0; 2.2] (Per Protocol data set, n = 20). NOWAPI(®) tended to underestimate residual AHI in a magnitude of two events per hour as compared to polygraphy. The device was well tolerated and the patient satisfaction was good. This clinical study confirmed prior bench tests, showing that NOWAPI(®) estimate of CPAP treatment duration was clinically acceptable and in agreement with polygraphy. Although a limited number of OSAS patients treated by CPAP were included, relevant findings for the device improvement were identified. Trial Registration ClinicalTrials.gov identifier: NCT01441622. The study was funded by Air Liquide HealthCare.

  13. Ant Colony Optimization Algorithm for Continuous Domains Based on Position Distribution Model of Ant Colony Foraging

    PubMed Central

    Liu, Liqiang; Dai, Yuntao

    2014-01-01

    Ant colony optimization algorithm for continuous domains is a major research direction for ant colony optimization algorithm. In this paper, we propose a distribution model of ant colony foraging, through analysis of the relationship between the position distribution and food source in the process of ant colony foraging. We design a continuous domain optimization algorithm based on the model and give the form of solution for the algorithm, the distribution model of pheromone, the update rules of ant colony position, and the processing method of constraint condition. Algorithm performance against a set of test trials was unconstrained optimization test functions and a set of optimization test functions, and test results of other algorithms are compared and analyzed to verify the correctness and effectiveness of the proposed algorithm. PMID:24955402

  14. Apical Lung Herniation Associated with Continuous Positive Airway Pressure in a 4-Year-Old Girl

    PubMed Central

    Lehmann, Christopher J.; Daftary, Ameet S.; Machogu, Evans M.

    2016-01-01

    We report a case of apical lung herniation through the superior thoracic aperture of an obese child using nocturnal CPAP. Lung herniation has been described in association with congenital thoracic abnormalities and elevated intra-thoracic pressure, such as trauma. This patient was hospitalized with community acquired pneumonia and required nocturnal CPAP for treatment of concurrent obstructive sleep apnea. Her lung hernia was discovered incidentally on routine follow-up chest radiography and resolved with cessation of CPAP treatment. Lung herniation in association with the use of continuous positive airway pressure (CPAP) has not been previously described. Citation: Lehmann CJ, Daftary AS, Machogu EM. Apical lung herniation associated with continuous positive airway pressure in a 4-year-old girl. J Clin Sleep Med 2016;12(11):1565–1566. PMID:27397657

  15. Ant colony optimization algorithm for continuous domains based on position distribution model of ant colony foraging.

    PubMed

    Liu, Liqiang; Dai, Yuntao; Gao, Jinyu

    2014-01-01

    Ant colony optimization algorithm for continuous domains is a major research direction for ant colony optimization algorithm. In this paper, we propose a distribution model of ant colony foraging, through analysis of the relationship between the position distribution and food source in the process of ant colony foraging. We design a continuous domain optimization algorithm based on the model and give the form of solution for the algorithm, the distribution model of pheromone, the update rules of ant colony position, and the processing method of constraint condition. Algorithm performance against a set of test trials was unconstrained optimization test functions and a set of optimization test functions, and test results of other algorithms are compared and analyzed to verify the correctness and effectiveness of the proposed algorithm.

  16. Nasal Harmony in Aguaruna.

    ERIC Educational Resources Information Center

    Moon, Gui-Sun

    A discussion of the nasal harmony of Aguaruna, a language of the Jivaroan family in South America, approaches the subject from the viewpoint of generative phonology. This theory of phonology proposes an underlying nasal consonant, later deleted, that accounts for vowel nasalization. Complex rules that suppose a complex system of vowel and…

  17. Nasal Harmony in Aguaruna.

    ERIC Educational Resources Information Center

    Moon, Gui-Sun

    A discussion of the nasal harmony of Aguaruna, a language of the Jivaroan family in South America, approaches the subject from the viewpoint of generative phonology. This theory of phonology proposes an underlying nasal consonant, later deleted, that accounts for vowel nasalization. Complex rules that suppose a complex system of vowel and…

  18. Nasal septal hematoma.

    PubMed

    Ginsburg, C M

    1998-04-01

    Nasal septal hematoma is a rare but potentially serious complication of nasal trauma. Proper management consists of early recognition, prompt surgical evacuation of the hematoma, and antimicrobial therapy if a secondary nasal septal abscess is suspected. Clindamycin is recommended as initial therapy until the results of cultures and susceptibility studies are available.

  19. Nasal computed tomography.

    PubMed

    Kuehn, Ned F

    2006-05-01

    Chronic nasal disease is often a challenge to diagnose. Computed tomography greatly enhances the ability to diagnose chronic nasal disease in dogs and cats. Nasal computed tomography provides detailed information regarding the extent of disease, accurate discrimination of neoplastic versus nonneoplastic diseases, and identification of areas of the nose to examine rhinoscopically and suspicious regions to target for biopsy.

  20. Supraglottic Atomization of Surfactant in Spontaneously Breathing Lambs Receiving Continuous Positive Airway Pressure.

    PubMed

    Milesi, Ilaria; Tingay, David G; Lavizzari, Anna; Bianco, Federico; Zannin, Emanuela; Tagliabue, Paolo; Mosca, Fabio; Ventura, Maria Luisa; Rajapaksa, Anushi; Perkins, Elizabeth J; Black, Don; Di Castri, Marco; Sourial, Magdy; Pohlmann, Gerhard; Dellaca', Raffaele L

    2017-09-01

    To determine the short-term tolerance, efficacy, and lung deposition of supraglottic atomized surfactant in spontaneously breathing lambs receiving continuous positive airway pressure. Prospective, randomized animal study. Animal research laboratory. Twenty-two preterm lambs on continuous positive airway pressure (132 ± 1 d gestational age). Animals receiving continuous positive airway pressure via binasal prongs at 8 cm H2O were randomized to receive atomized surfactant at approximately 60-minute of life (atom; n = 15) or not (control; n = 7). The atom group received 200 mg/kg of poractant alfa (Curosurf; Chiesi Farmaceutici SpA, Parma, Italy) over 45 minutes via a novel atomizer located in the upper pharynx that synchronized surfactant delivery with the inspiratory phase. Arterial blood gas, regional distribution of tidal ventilation (electrical impedance tomography), and carotid blood flow were recorded every 15 minutes until 90 minutes after stabilizing on continuous positive airway pressure. Gas exchange, respiratory rate, and hemodynamic variables, including carotid blood flow, remained stable during surfactant treatment. There was a significant improvement in arterial alveolar ratio after surfactant delivery in the atom group (p < 0.05; Sidak posttests), while there was no difference in PaCO2. Electrical impedance tomography data showed a more uniform pattern of ventilation in the atom group. In the atom group, the median (interquartile range) deposition of surfactant in the lung was 32% (22-43%) of the delivered dose, with an even distribution between the right and the left lungs. In our model of spontaneously breathing lambs receiving CPAP, supraglottic atomization of Curosurf via a novel device was safe, improved oxygenation and ventilation homogeneity compared with CPAP only, and provided a relatively large lung deposition suggesting clinical utility.

  1. Definability of semifields of continuous positive functions by the lattices of their subalgebras

    NASA Astrophysics Data System (ADS)

    Sidorov, V. V.

    2016-09-01

    We consider the lattice {A}(U(X)) of subalgebras of a semifield U(X) of continuous positive functions on an arbitrary topological space X and its sublattice {A}_1(U(X)) of subalgebras with unity. The main result of the paper is the proof of the definability of any semifield U(X) both by the lattice {A}(U(X)) and by its sublattice {A}_1(U(X)). Bibliography: 12 titles.

  2. Upper airway obstruction during midazolam sedation: modification by nasal CPAP.

    PubMed

    Nozaki-Taguchi, N; Isono, S; Nishino, T; Numai, T; Taguchi, N

    1995-08-01

    We examined the depressant effect of midazolam on respiration in 21 healthy women undergoing lower abdominal surgery with spinal anaesthesia. Airway gas flow, airway pressure, and the sound of snoring were recorded together with arterial oxygen saturation (SpO2). After spinal anaesthesia was established, subjects were deeply sedated with pentazocine 15 mg followed by incremental doses of midazolam 1 mg i.v. up to 0.1 mg.kg-1. When SpO2 decreased to < 90% or snoring and/or apnoea was observed, continuous positive airway pressure applied through the nose (nasal CPAP) was increased until the respiratory deterioration was reversed. While one patient remained free of respiratory events, the other 20 patients were successfully treated with nasal CPAP restoring normal SpO2 (95.5 +/- 1.7%) without snoring. Stepwise reduction of nasal CPAP determined the minimally effective CPAP to prevent snoring to be 5.1 +/- 2.1 cm H2O. Further reduction of nasal CPAP induced snoring in 15 patients and obstructive apnoea in five patients with the latter accompanied by a severe reduction of SpO2 (87.4 +/- 6.1%). Patients with apnoea were older than those who snored (P < 0.05. We conclude that upper airway obstruction contributes considerably to decreases in SpO2 during midazolam sedation for spinal anaesthesia.

  3. Nasal bone clip: a novel approach to nasal bone fixation.

    PubMed

    Kosaka, Masaaki; Sai, Kenshin; Shiratake, Yasuhisa; Ohjimi, Hiroyuki

    2010-03-01

    Nasal bone fracture is a common injury, but its repair can be unexpectedly difficult. To date, intranasal gauze packing has been used to support the nasal bone in position and to maintain contact between the mucosa of the septum and the cartilage. This gauze packing, however, has a tendency to shift, resulting in an inflammatory response characterized by a foul odor until removal, which detracts from the comfort of the patient. We developed a novel device, the nasal bone clip (NBC), which provides a satisfactory nasal airway and improved comfort. A 1.2-mm Kirschner wire and a small piece of hydrocolloid wound dressing are used. The single wire is bent into a double-curved shape, after which each of the 2 tips is curled with pliers. The end of the wire in the nasal passage is covered with a piece of wound dressing to protect the mucosa. After reduction, the external portion of the wire is inserted on the surface of the splint. The NBC was applied in 14 cases: 12 instances of fresh fractures and 2 of old fractures; there were 8 men and 6 women; their mean age was 19.9 years. Complications were not observed; moreover, no patients exhibited problems during the treatment. The advantages of the NBC are that all materials are available in the operating room or outpatient department, it is low cost, it is readily installable and detachable, it affords superior support for gauze packing, it provides effective external splinting with intranasal support, it never disturbs the nasal airway, and it offers comfort.

  4. Nasal foreign body removal in children.

    PubMed

    Kiger, James R; Brenkert, Timothy E; Losek, Joseph D

    2008-11-01

    Nasal foreign bodies in children are often managed in the pediatric emergency department. The child is usually between 2 and 4 years old, and the foreign body is most commonly a plastic toy or bead. Nasal foreign bodies are removed by a number of techniques. Positive-pressure expulsion is accomplished by orally applied pressure via a parent's mouth or an Ambu bag or by nasally applied pressure via a catheter or an oxygen source. The object can be washed out with nasally applied saline. Direct mechanical extraction is possible with a variety of tools, including forceps, hooks, or balloon-tipped catheters. Each method carries its own risks and benefits. Serious complications of nasal foreign bodies include posterior dislodgement and aspiration, trauma caused by the object itself or removal attempts, infection, and choanal stenosis. Magnets and button batteries require emergent removal as they carry the risk of septal perforation or necrosis, which may develop within a relatively short time.

  5. Respiratory mode, nasal patency and palatine dimensions.

    PubMed

    Trevisan, Maria Elaine; Bellinaso, José Humberto; Pacheco, Andrielle de Bitencourt; Augé, Luciana Barros; Silva, Ana Maria Toniolo da; Corrêa, Eliane Castilhos Rodrigues

    2015-01-01

    To investigate the influence of breathing mode and nasal patency in the dimensions of the hard palate by comparing mouth breathing (MB) and nasal breathing (NB) adults. Seventy-seven individuals, distributed into the MB group (n=38) and the NB group (n=39), of both genders and aged between 18 and 30 years old, took part in the study. The respiratory mode diagnosis was based on anamnesis, physical characteristics, and otorhinolaryngological examination. The volunteers were evaluated in terms of nasal patency, with a peak nasal inspiratory flow (PNIF) meter, and obstruction symptoms, by a Nasal Obstruction Symptom Evaluation (NOSE) scale, and had their transversal and vertical hard palate dimensions measured with a digital caliper in plaster models. Comparing both groups, the MB group presented significantly higher values in the NOSE scale, lower values in the PNIF, lower values in the transversal distance of the palate in the intercanine region, and significantly higher values in the vertical distance in the regions of the first and second premolars and molars. There was a negative correlation between PNIF and NOSE, and a positive correlation between PNIF and transversal distance of the palate in the region of the first premolars. MB adults presented reduced nasal patency and a higher degree of nasal obstruction symptoms. The hard palate was morphologically narrower and deeper in adults with the MB mode compared to the NB mode. Moreover, it was concluded that the smaller the nasal patency, the greater the obstruction symptoms and the narrower the hard palate.

  6. Effect of a heated humidifier during continuous positive airway pressure delivered by a helmet

    PubMed Central

    Chiumello, Davide; Chierichetti, Monica; Tallarini, Federica; Cozzi, Paola; Cressoni, Massimo; Polli, Federico; Colombo, Riccardo; Castelli, Antonio; Gattinoni, Luciano

    2008-01-01

    Introduction The helmet may be an effective interface for the delivery of noninvasive positive pressure ventilation. The high internal gas volume of the helmet can act as a 'mixing chamber', in which the humidity of the patient's expired alveolar gases increases the humidity of the dry medical gases, thus avoiding the need for active humidification. We evaluated the temperature and humidity of respiratory gases inside the helmet, with and without a heated humidifier, during continuous positive airway pressure (CPAP) delivered with a helmet. Methods Nine patients with acute respiratory failure (arterial oxygen tension/fractional inspired oxygen ratio 209 ± 52 mmHg) and 10 healthy individuals were subjected to CPAP. The CPAP was delivered either through a mechanical ventilator or by continuous low (40 l/min) or high flow (80 l/min). Humidity was measured inside the helmet using a capacitive hygrometer. The level of patient comfort was evaluated using a continuous scale. Results In patients with acute respiratory failure, the heated humidifier significantly increased the absolute humidity from 18.4 ± 5.5 mgH2O/l to 34.1 ± 2.8 mgH2O/l during ventilator CPAP, from 11.4 ± 4.8 mgH2O/l to 33.9 ± 1.9 mgH2O/l during continuous low-flow CPAP, and from 6.4 ± 1.8 mgH2O/l to 24.2 ± 5.4 mgH2O/l during continuous high-flow CPAP. Without the heated humidifier, the absolute humidity was significantly higher with ventilator CPAP than with continuous low-flow and high-flow CPAP. The level of comfort was similar for all the three modes of ventilation and with or without the heated humidifier. The findings in healthy individuals were similar to those in the patients with acute respiratory failure. Conclusion The fresh gas flowing through the helmet with continuous flow CPAP systems limited the possibility to increase the humidity. We suggest that a heated humidifier should be employed with continuous flow CPAP systems. PMID:18426561

  7. The effect of short-term withdrawal from continuous positive airway pressure therapy on sympathetic activity and markers of vascular inflammation in subjects with obstructive sleep apnoea.

    PubMed

    Phillips, Craig L; Yang, Qiao; Williams, Andrew; Roth, Michael; Yee, Brendon J; Hedner, Jan A; Berend, Norbert; Grunstein, Ronald R

    2007-06-01

    Obstructive sleep apnoea (OSA) is commonly associated with cardiovascular disease and sympathetic activation. However, it is unclear whether this association is independent of obesity and to what extent treatment with nasal continuous positive airway pressure (CPAP) alleviates the vascular inflammation that underpins cardiovascular disease. We therefore evaluated whether short-term withdrawal from CPAP therapy in subjects with moderate-severe OSA would result in increased levels of sympathetic activity and circulating inflammatory cytokines independent of weight. Vascular inflammatory markers (hsCRP, hsIL-6 and hsTNF-alpha) were assessed in 20 subjects after one and seven nights of withdrawal from CPAP together with the hypoxia-responsive angiogenic marker VEGF and urinary catecholamines. Compared with baseline on CPAP, withdrawal from therapy resulted in an immediate return of OSA with an increase in RDI to 26.7 +/- 5.2 and 39.0 +/- 5.9 events per hour after one and seven nights without CPAP, respectively (both P < 0.0001). This was accompanied by a concomitant rise in daytime urinary noradrenaline (P < 0.0001) after seven nights CPAP withdrawal that was positively associated with the severity of hypoxaemia. In contrast, withdrawal from CPAP therapy was not accompanied by any change in measured cytokines or VEGF (all P > 0.1). In conclusion, 1 week of CPAP withdrawal was associated with a return of OSA and a marked increase in sympathetic activity without a concomitant elevation of vascular inflammatory markers.

  8. [Clinical analysis of nasal resistance and pulmonary function testing in patients with chronic nasal-sinusitis and nasal polyps].

    PubMed

    Liao, Hua; Shen, Ying; Wang, Pengjun

    2015-05-01

    To study the pulmonary function and nasal resistance characteristics of patients with chronic nose-sinusitis and nasal polyps (CRSwNP), to explore the evaluation role of nasal resistance in nasal ventilation function and the effect of endoscopic sinus surgery on pulmonary function in patients with CRSwNP. Fifty CRSwNP patients that met the study criteria were selected . The patients were performed endoscopic surgeries according to Messerklinger surgical procedures under general anesthesia. Extent of surgery was based on preoperative CT showing the range of the lesion of disease and endoscopic findings. Perioperative treatments contained intranasal corticosteroids, cephalosporin or penicillin antibiotics, nasal irrigation and other treatments. Main outcome measures included visual analog scale (VAS), endoscopic Lind-Kennedy scores, nasal resistence, pulmonary function in patientsone week before and after surgery, three months and six months after surgery. Pulmonary function includes forced expiratory volume in one second (FEV1), forced vital capacity FEV1/FVC and peak expiratory flow (PEF). The study found that there were significantly positive correlations among VAS score, Lund-Kennedy score and nasal resistance (P < 0.05) in CRSwNP patients, but there is a significantly negative correlation between VAS score, Lund-Kennedy score, nasal resistance and pulmonary function indexes of FEV1, FVC and PEF (P < 0.05). The VAS score, Lund-Kennedy score and nasal resistance values of CRSwNP patients were decreased significantly after comprehensive treatments with nasal endoscopic operation as the major one, the difference was statistically different (P < 0.05). And the pulmonary function indexs (FEV1, FVC, PEF) were significantly increased after surgery in CRSwNP patients. The nasal resistance can objectively and reliably reflect the degree of nasal congestion and the recovery of nasal function in CRSwNP patients after endoscopic sinus surgery. The detection method of nasal

  9. Prone positioning does not affect cannula function during extracorporeal membrane oxygenation or continuous renal replacement therapy

    PubMed Central

    Goettler, Claudia E; Pryor, John P; Hoey, Brian A; Phillips, JoAnne K; Balas, Michelle C; Shapiro, Michael B

    2002-01-01

    Introduction Prone positioning in respiratory failure has been shown to be a useful adjunct in the treatment of severe hypoxia. However, the prone position can result in dislodgment or malfunction of tubes and cannulae. Certain patients receiving extracorporeal membrane oxygenation (ECMO) or continuous renal replacement therapy (CRRT) may also benefit from positional therapy. The impact of cannula-related complications in these patients is potentially disastrous. The safety and efficacy of prone positioning of these patients has not been previously reported. Materials and methods A retrospective chart review evaluated ECMO or CRRT cannula location, and displacement or malfunction during positional change or while prone. The study was set in a General Surgery and Trauma Intensive Care Unit. The subjects were all patients at our institution who simultaneously underwent ECMO or CRRT and prone positioning from July 1996 to July 2001. There were no interventions. Results Ten patients underwent ECMO and 42 patients underwent CRRT during the study period. Seven patients underwent simultaneous prone positioning and either ECMO (4/10) or CRRT (4/42). A total of 68 turning events (prone to supine or supine to prone) were recorded, with each patient averaging 9.7 (range, 4–16) turning episodes. Turning was performed with sheets and extra nursing personnel; no special mechanical assist devices were used. No patients experienced inadvertent cannula removal during turning. Two patients had poor flow through their cannulae. In one patient, this occurred in the supine position and required repositioning of the cannula. In the second patient, cannulae were changed twice and flow was poor in both the supine and the prone positions. All ECMO and CRRT patients received venous cannulae. Cannula location (seven internal jugular and 11 femoral) did not the affect risk of malfunction. Discussion and conclusions Patients with venous cannulae for ECMO or CRRT can be safely placed in the

  10. Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome

    PubMed Central

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-01-01

    Study Objective: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Design: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Setting: Accredited laboratory in a university hospital. Patients or Participants: Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. Interventions: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. Measurements and Results: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H2O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Conclusions: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Clinical Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx Citation: Teo M

  11. Improvement of nasal breathing and patient satisfaction by the endonasal dilator Airmax®.

    PubMed

    Hellings, P W; Nolst Trenite, G J

    2014-03-01

    Patients suffering from nasal obstruction due to external nasal valve dysfunction may benefit from either corrective surgery or a conservative approach with a nasal dilator. At present, devices for widening the external nasal valve region can be applied externally or endonasally. It remains unknown to what extent the en dona sal dilator Airmax® objectively improves the nasal flow and can be offered as an alternative for surgery. Thirty patients suffering from nasal obstruction due to external nasal valve problems were proposed to use the nasal dilator for 4 weeks as an alternative for corrective surgery. The improvement of nasal flow by the dilator was evaluated by measuring the peak nasal inspiratory flow (PNIF). Then, patients were asked for their willingness to continue to use the nasal dilator or to undergo nasal valve surgery. The endonasal dilator improved the mean PNIF from baseline values with a mean increase of 176.1 o/o. After a 4 week trial period, 19 of 30 patients expressed the intention to continue the use of the nasal dilator. Inappropriate size, local irritation and/or aesthetic nasal complaints were mentioned by the other patients as reasons for discontinuation of using the nasal dilator. The endonasal dilator Airmax® represents a powerful device to improve nasal breathing in the target patients and therefore represents a good alternative for corrective surgery.

  12. Effects of rider position on continuous wave Doppler responses to maximal cycle ergometry.

    PubMed Central

    Franke, W D; Betz, C B; Humphrey, R H

    1994-01-01

    Using 10 well-trained (VO2peak = 60.6 ml kg-1min-1) college age cyclists and continuous wave Doppler echocardiography, peak acceleration (PkA) and velocity (PkV) of blood flow in the ascending aorta, and the stroke velocity integral (SVI) were assessed to determine if rider position influenced the central haemodynamic responses to graded maximal cycle ergometry. Cyclist position was determined by hand placement on the uprights (UPRI) or drops (DROP) of conventional handlebars or using aerodynamic handlebars (AHB). All subjects consistently achieved a peak workload of 300 W. The Doppler variables did not differ significantly between rider positions at each stage of the maximal exercise tests but did change in response to increasing workloads. PkA was significantly (P < 0.05) greater at workloads > or = 240 W versus < or = 120 W. PkV increased significantly (P < 0.05) up to 180 W and then reached a plateau. SVI increased to a workload of 120 W and then progressively declined, becoming significantly (P < 0.05) less at 300 W. For each stage, neither submaximal VO2, VI nor heart rate (HR) differed significantly between each trial. These results suggest that rider position does not affect the physiological response to maximal bicycle ergometry as responses to each position are similar. PMID:8044492

  13. Linear motor drive system for continuous-path closed-loop position control of an object

    DOEpatents

    Barkman, William E.

    1980-01-01

    A precision numerical controlled servo-positioning system is provided for continuous closed-loop position control of a machine slide or platform driven by a linear-induction motor. The system utilizes filtered velocity feedback to provide system stability required to operate with a system gain of 100 inches/minute/0.001 inch of following error. The filtered velocity feedback signal is derived from the position output signals of a laser interferometer utilized to monitor the movement of the slide. Air-bearing slides mounted to a stable support are utilized to minimize friction and small irregularities in the slideway which would tend to introduce positioning errors. A microprocessor is programmed to read command and feedback information and converts this information into the system following error signal. This error signal is summed with the negative filtered velocity feedback signal at the input of a servo amplifier whose output serves as the drive power signal to the linear motor position control coil.

  14. Discrete and continuous fractional persistence problems - the positivity property and applications

    NASA Astrophysics Data System (ADS)

    Cresson, Jacky; Szafrańska, Anna

    2017-03-01

    In this article, we study the continuous and discrete fractional persistence problem which looks for the persistence of properties of a given classical (α = 1) differential equation in the fractional case (here using fractional Caputo's derivatives) and the numerical scheme which are associated (here with discrete Grünwald-Letnikov derivatives). Our main concerns are positivity, order preserving ,equilibrium points and stability of these points. We formulate explicit conditions under which a fractional system preserves positivity. We deduce also sufficient conditions to ensure order preserving. We deduce from these results a fractional persistence theorem which ensures that positivity, order preserving, equilibrium points and stability is preserved under a Caputo fractional embedding of a given differential equation. At the discrete level, the problem is more complicated. Following a strategy initiated by R. Mickens dealing with non local approximations, we define a non standard finite difference scheme for fractional differential equations based on discrete Grünwald-Letnikov derivatives, which preserves positivity unconditionally on the discretization increment. We deduce a discrete version of the fractional persistence theorem for what concerns positivity and equilibrium points. We then apply our results to study a fractional prey-predator model introduced by Javidi et al.

  15. Parametric positioning of a continuous crystal PET detector with depth of interaction decoding

    PubMed Central

    Ling, T; Burnett, T H; Lewellen, T K; Miyaoka, R S

    2009-01-01

    Here we demonstrate a parametric positioning method on a continuous crystal detector. Three different models for the light distribution were tested. Diagnosis of the residues showed that the parametric model fits the experimental data better than Gaussian and Cauchy models in our particular experimental setup. Based on the correlation between the spread and the peak value of the light distribution model with the depth of interaction (DOI), we were able to estimate the three-dimensional position of a scintillation event. On our continuous miniature crystal element (cMiCE) detector module with 8 mm thick LYSO crystal, the intrinsic spatial resolution is 1.06 mm at the center and 1.27 mm at the corner using a maximum-likelihood estimation (MLE) method and the parametric model. The DOI resolution (full width at half maximum) is estimated to be ∼3.24 mm. The positioning method using the parametric model outperformed the Gaussian and Cauchy models, in both MLE and weighted least-squares (WLS) fitting methods. The key feature of this technique is that it requires very little calibration of the detector, but still retains high resolution and high sensitivity. PMID:18364542

  16. Parametric positioning of a continuous crystal PET detector with depth of interaction decoding.

    PubMed

    Ling, T; Burnett, T H; Lewellen, T K; Miyaoka, R S

    2008-04-07

    Here we demonstrate a parametric positioning method on a continuous crystal detector. Three different models for the light distribution were tested. Diagnosis of the residues showed that the parametric model fits the experimental data better than Gaussian and Cauchy models in our particular experimental setup. Based on the correlation between the spread and the peak value of the light distribution model with the depth of interaction (DOI), we were able to estimate the three-dimensional position of a scintillation event. On our continuous miniature crystal element (cMiCE) detector module with 8 mm thick LYSO crystal, the intrinsic spatial resolution is 1.06 mm at the center and 1.27 mm at the corner using a maximum-likelihood estimation (MLE) method and the parametric model. The DOI resolution (full width at half maximum) is estimated to be approximately 3.24 mm. The positioning method using the parametric model outperformed the Gaussian and Cauchy models, in both MLE and weighted least-squares (WLS) fitting methods. The key feature of this technique is that it requires very little calibration of the detector, but still retains high resolution and high sensitivity.

  17. Hypoxia depresses nitric oxide output in the human nasal airways.

    PubMed

    Haight, J S; Qian, W; Daya, H; Chalmers, P; Zamel, N

    2000-03-01

    The role of oxygen in the nasal air on nasal nitric oxide (NO) output was studied in 13 adult volunteers. Nasal NO was measured while air containing oxygen (0%-100% in nitrogen) was aspirated through the nasal airway before and after the topical application of xylometazoline. The mean nasal NO output of the untreated nose was 507.8 +/- 161.9 nL/min (mean +/- SD) when 21% oxygen was aspirated through the nasal cavities in series and remained unaltered by 100% O2 (P = .79). Below 10% oxygen the reduction in nasal NO output correlated positively and significantly with the decrease in oxygen concentration (r2 = 0.14). NO output was 245.2 +/- 153.4 nL/min at 0% oxygen, a significant decline from 21% oxygen (P < .0001). Nasal vasoconstriction induced by xylometazoline and alterations in the blood oxygen content by a maximal breath-holding or breathing 100% oxygen did not alter nasal NO in hypoxia (P = .41). Nasal NO output is markedly depressed in hypoxia and is oxygen dependent at concentrations of less than 10%. Approximately 50% of nasally generated NO is produced from oxygen in nasal air or regulated by it.

  18. Older individuals have increased oro-nasal breathing during sleep.

    PubMed

    Madronio, M R; Di Somma, E; Stavrinou, R; Kirkness, J P; Goldfinch, E; Wheatley, J R; Amis, T C

    2004-07-01

    Breathing route during sleep has been studied very little, however, it has potential importance in the pathophysiology of sleep disordered breathing. Using overnight polysomnography, with separate nasal and oral thermocouple probes, data were obtained from 41 subjects (snorers and nonsnorers; 25 male and 16 female; aged 20-66 yrs). Awake, upright, inspiratory nasal resistance (Rn) was measured using posterior rhinomanometry. Each 30-s sleep epoch (not affected by apnoeas/hypopnoeas) was scored for presence of nasal and/or oral breathing. Overnight, seven subjects breathed nasally, one subject oro-nasally and the remainder switched between nasal and oro-nasal breathing. Oral-only breathing rarely occurred. Nasal breathing epochs were 55.79 (69.78) per cent of total sleep epochs (%TSE; median (interquartile range)), a value not significantly different to that for oro-nasal (TSE: 44.21 (68.66)%). Oro-nasal breathing was not related to snoring, sleep stage, posture, body mass index, height, weight, Rn (2.19 (1.77) cm H2O x L(-1) x sec(-1)) or sex, but was positively associated with age. Subjects > or = 40 yrs were approximately six times more likely than younger subjects to spend >50% of sleep epochs utilising oro-nasal breathing. Ageing is associated with an increasing occurrence of oro-nasal breathing during sleep.

  19. Oral appliance titration and nasal resistance in nonapneic subjects.

    PubMed

    Okawara, Yoko; Tsuiki, Satoru; Hiyama, Shigetoshi; Hashimoto, Koji; Ono, Takashi; Ohyama, Kimie

    2004-11-01

    Initial mandibular position might be a key factor leading to rapid therapeutic outcome in oral appliance therapy for patients with obstructive sleep apnea (OSA). The purpose of this study was to investigate the effects of an adjustable oral appliance on nasal resistance in 7 nonapneic patients. Upright and supine nasal resistance was measured for each subject with an adjustable oral appliance in place in 3 mandibular positions: most retruded (MAX0), maximum protrusion (MAX100), and 67% of MAX100 (MAX67). A significant decrease in upright and supine nasal resistance was observed between MAX0 and MAX67 (P < .01), and between MAX0 and MAX100 (P < .01), but not between MAX67 and MAX100. In addition, there was a positive correlation between the nasal resistance at MAX0 and the nasal resistance change from MAX0 to MAX67 (P < .01), indicating that when the mandible was advanced from MAX0 to MAX67, the more nasal resistance at MAX0, the greater the reduction in nasal resistance at MAX67. These findings suggest that MAX67 might be indicated as the initial mandibular position and that gradual anterior titration of mandibular position beyond MAX67 would give OSA patients rapid therapeutic effects by reducing the nasal resistance. Moreover, OSA patients with augmented nasal resistance at MAX0 might have a greater reduction in nasal resistance in response to MAX67 in oral appliance therapy.

  20. Septal suturing following nasal septoplasty, a valid alternative for nasal packing?

    PubMed

    Lemmens, W; Lemkens, P

    2001-01-01

    Septal suturing following nasal septoplasty, a valid alternative for nasal packing? After septal surgery most surgeons still routinely perform nasal packing since this is generally recommended. The aims of packing are numerous: haemostasis, prevention of haematoma, increase septal flap apposition, closure of dead space and prevention of displacement of the replaced cartilage. However, nasal packing is not an innocuous procedure and may lead to cardiovascular changes, continued bleeding, nasal injury, hypoxia, foreign body reaction or infection. The major disadvantage of nasal packing is patient discomfort--usually necessitating hospital stay--and the need to administer antibiotics. Therefore alternatives were sought. Sessions, Lee and Vukovic conceived and reported in the eighties forms of continuous septal suturing, but are not widely used. A similar technique of septal suturing after nasal septoplasty without nasal packing was used in 226 consecutive surgical procedures and reviewed retrospectively. Complications like postoperative episodes of bleeding, infections, septal haematomas, septal perforations or synechia were not noted. On one patient a recurrence of the septal deviation occurred. Patients reported almost no discomfort. Moreover, the septal surgery procedure could be carried out on a day-surgery basis. Readmission of a patient was never necessary. Based on these observations the septal suturing technique is a valid alternative to intranasal packing following septal surgery.

  1. Management of severe obstructive sleep apnea using mandibular advancement devices with auto continuous positive airway pressures

    PubMed Central

    Upadhyay, Rashmi; Dubey, Abhishek; Kant, Surya; Singh, Balendra Pratap

    2015-01-01

    The use of continuous positive airway pressures (CPAP) is considered standard treatment of moderate to severe obstructive sleep apnea (OSA). Treatment of the disease poses a great challenge not only for its diagnostic purpose but also for its treatment part. In about 29-83% of the patients, treatment is difficult because of non-compliance resulting due to high pressures, air leaks and other related issues. In such situations, alternative methods of treatment need to be looked for so as to ascertain better management. Mandibular advancement devices along with CPAP may show better treatment outcome in specific situations. PMID:25814802

  2. Nasal ventilation is more effective than combined oral-nasal ventilation during induction of general anesthesia in adult subjects.

    PubMed

    Liang, Yafen; Kimball, William R; Kacmarek, Robert M; Zapol, Warren M; Jiang, Yandong

    2008-06-01

    The authors hypothesized that nasal mask ventilation may be more effective than combined oral-nasal mask ventilation during induction of general anesthesia. They tested this hypothesis by comparing the volume of carbon dioxide removed per breath with nasal versus combined oral-nasal mask ventilation in nonparalyzed, apneic, adult subjects during induction of general anesthesia. Fifteen adult subjects receiving general anesthesia were ventilated first with a combined oral-nasal mask and then with only a nasal mask. The patient's head was maintained in a neutral position, without head extension or lower jaw thrust. Respiratory parameters were recorded simultaneously from both the nasal and oral masks regardless of ventilation approach. The volume of carbon dioxide removed per breath during nasal mask ventilation (median, 5.0 ml; interquartile range, 3.4-8.8 ml) was significantly larger than that during combined oral-nasal mask ventilation (median, 0.0 ml; interquartile range, 0.0-0.4 ml; P = 0.001); even the peak inspiratory airway pressure during nasal ventilation (16.7 +/- 2.7 cm H2O) was lower than that during combined oral-nasal ventilation (24.5 +/- 4.7 cm H2O; P = 0.002). The expiratory tidal volume during nasal ventilation (259.8 +/- 134.2 ml) was also larger than that during combined oral-nasal ventilation (98.9 +/- 103.4 ml; P = 0.003). Nasal mask ventilation was more effective than combined oral-nasal mask ventilation in apneic, nonparalyzed, adult subjects during induction of general anesthesia. The authors suggest that nasal mask ventilation, rather than full facemask ventilation, be considered during induction of anesthesia.

  3. Single-point position and transition defects in continuous time quantum walks

    PubMed Central

    Li, Z. J.; Wang, J. B.

    2015-01-01

    We present a detailed analysis of continuous time quantum walks (CTQW) with both position and transition defects defined at a single point in the line. Analytical solutions of both traveling waves and bound states are obtained, which provide valuable insight into the dynamics of CTQW. The number of bound states is found to be critically dependent on the defect parameters, and the localized probability peaks can be readily obtained by projecting the state vector of CTQW on to these bound states. The interference between two bound states are also observed in the case of a transition defect. The spreading of CTQW probability over the line can be finely tuned by varying the position and transition defect parameters, offering the possibility of precision quantum control of the system. PMID:26323855

  4. Continuous and Discrete Space Particle Filters for Predictions in Acoustic Positioning

    NASA Astrophysics Data System (ADS)

    Bauer, Will; Kim, Surrey; Kouritzin, Michael A.

    2002-12-01

    Predicting the future state of a random dynamic signal based on corrupted, distorted, and partial observations is vital for proper real-time control of a system that includes time delay. Motivated by problems from Acoustic Positioning Research Inc., we consider the continual automated illumination of an object moving within a bounded domain, which requires object location prediction due to inherent mechanical and physical time lags associated with robotic lighting. Quality computational predictions demand high fidelity models for the coupled moving object signal and observation equipment pair. In our current problem, the signal represents the vector position, orientation, and velocity of a stage performer. Acoustic observations are formed by timing ultrasonic waves traveling from four perimeter speakers to a microphone attached to the performer. The goal is to schedule lighting movements that are coordinated with the performer by anticipating his/her future position based upon these observations using filtering theory. Particle system based methods have experienced rapid development and have become an essential technique of contemporary filtering strategies. Hitherto, researchers have largely focused on continuous state particle filters, ranging from traditional weighted particle filters to adaptive refining particle filters, readily able to perform path-space estimation and prediction. Herein, we compare the performance of a state-of-the-art refining particle filter to that of a novel discrete-space particle filter on the acoustic positioning problem. By discrete space particle filter we mean a Markov chain that counts particles in discretized cells of the signal state space in order to form an approximated unnormalized distribution of the signal state. For both filters mentioned above, we will examine issues like the mean time to localize a signal, the fidelity of filter estimates at various signal to noise ratios, computational costs, and the effect of signal

  5. [Acceptability and compliance to long-term continuous positive pressure treatment].

    PubMed

    Berkani, K; Dimet, J

    2015-03-01

    Compliance with continuous positive pressure treatment (CPAP) is a determining factor in the management of the obstructive sleep apnea syndrome (OSAS). Long-term compliance has been poorly studied. The probability of long-term continuation of CPAP was evaluated retrospectively by an analysis of survival in 252 patients treated by CPAP after a screening of 472 patients during the years 2002 and 2003. Twenty-eight patients fulfilling the criteria for CPAP immediately refused the treatment. The mean follow-up for the 252 treated patients was 76.9±46.4 months, with 38 patients having died and 75 having discontinued treatment during the period. The 136 patients who continued treatment used CPAP for a mean of 7.4±1.6hours daily. The probability of continuing treatment was 71% at 5 years and 68% at 10 years. The severity of OSAS was a predictive factor for long-term CPAP compliance, with a 10-year compliance of 82% in patients having an apnoea/hypopnoea index >60, versus 68% with an index between 30-60 and 44% with an index <30. Long-term CPAP treatment is globally well accepted, with a 68% probability of continuing treatment for 10 years, particularly in the most severely affected patients. Long-term daily compliance is very satisfactory. Copyright © 2014 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  6. [Nasal breath recovery and rhinoplasty in cleft lip and palate patient with unilateral choanal atresia].

    PubMed

    Chkadua, T Z; Ivanova, M D; Daminov, R O; Brusova, L A; Savvateeva, D M

    2016-01-01

    The paper presents the analysis of clinical case of endoscopic nasal breath restoration and elimination of the secondary cleft lip nasal deformity in 27 years old patient with unilateral choanal atresia and secondary nasal deformity after rhinocheiloplasty. Preoperative examination revealed the absence of nasal breathing on collateral side due to complete bone choanal atresia. Surgical treatment included endoscopic choanal repair, elimination of the secondary nasal deformity, septoplasty, conchotomy and lateroposition of the inferior conchae. The treatment resulted in nasal breath restoration and elimination of nasal deformity. Long-term follow-up at 1 and 12 months post-operatively proved stable positive aesthetic and functional results.

  7. [Nasal septum cartilage-silica gel complex for repairing nasal deformities of unilateral cleft lip].

    PubMed

    Li, Qingwei; Sheng, Zunqi; Tang, Shengjian; Yang, Biaobing; Yu, Xiaohua

    2009-07-01

    To evaluate the operative methods and therapeutic effects of nasal septum cartilage-silica gel complex for two-stage repair of nasal deformities of unilateral cleft lip. From June 2001 to June 2007, 38 cases of secondary nasal deformity and septum deviation of cleft lip were treated with transplanting nasal septum cartilage-silica gel complex. Among of them, there were 21 males and 17 females, aging 14-23 years with an average of 17.6 years. All cases were with nasal deformities of unilateral cleft lip, including 21 cases of complete cleft lip and 17 cases of incomplete cleft lip. The locations were left side in 26 cases and right side in 12 cases. Nasal deformities were columella nasi deflexion, flattened nasal tip, pteleorrhine and alanasi collapse. The patients received 1-4 times operations, and the interval of two operations was 3-10 years (mean 5.5 years). According to nasal deformity, the nasal septum cartilage of 1.8 cm x 1.2 cm was cut, and transplanted into the nose point phantom surface forming "the shield" to extend nose column and to raise the tip of the nose. At the same time the nasal tip fat-connective tissue flap graft with fat knot was given. After fixation, the nasal alar cartilage and soft tissues were reduced to normal position. Primary healing of the incisions was achieved in all cases. The nasal deformity was corrected. The postoperative follow-up period was 12-18 months with an average of 15.6 months. All the patients of regional cartilage scars had no complication. The figure of nose was slinky, the height of apex of nose and the shape of nose was natural, the apex of nose, nasal ala, nostrils and nasal columella were satisfactory [(the results were satisfactory in 30 cases (78.9%), general in 8 cases (21.1%)]. The nose department overall esthetics shape was improved in all the patients, no complications of the phantom sliding, shifting and exposure, hemorrhage and infection occurred. The nasal septum cartilage-silica gel complex to repair

  8. [Bilateral parotitis in a patient under continuous positive airway pressure treatment].

    PubMed

    Abdullayev, Ruslan; Saral, Filiz Cosku; Kucukebe, Omer Burak; Sayiner, Hakan Sezgin; Bayraktar, Cem; Akgun, Sadik

    Many conditions such as bacterial and viral infectious diseases, mechanical obstruction due to air and calculi and drugs can cause parotitis. We present a case of unusual bilateral parotitis in a patient under non-invasive continuous positive airway pressure (CPAP) therapy for chronic obstructive pulmonary disease exacerbation in intensive care unit. A 36-year-old patient was admitted to intensive care unit with the diagnosis of chronic obstructive pulmonary disease exacerbation. Antibiotherapy, bronchodilator therapy and non-invasive positive pressure ventilation were applied as treatment regimen. Painless swellings developed on the 3rd day of admission on the right and a day after this on the left parotid glands. Amylase levels were increased and ultrasonographic evaluation revealed bilateral parotitis. No intervention was made and the therapy was continued. The patient was discharged on the 6th day with clinical improvement and regression of parotid swellings without any complications. Parotitis may have occurred after retrograde air flow in the Stensen duct during CPAP application. After the exclusion of possible viral and bacteriological etiologies and possible drug reactions we can focus on this diagnosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  9. Spontaneous breathing patterns of very preterm infants treated with continuous positive airway pressure at birth.

    PubMed

    te Pas, Arjan B; Davis, Peter G; Kamlin, C Omar F; Dawson, Jennifer; O'Donnell, Colm P F; Morley, Colin J

    2008-09-01

    There are no data describing how very preterm infants breathe spontaneously immediately after birth. We studied a convenience sample of spontaneously breathing infants continuous positive airway pressure at birth. Airway pressure and flow were measured and each breath analyzed. Twelve infants had 792 breaths suitable for analysis. Results are given as mean (SD). Gestational age and birth weight were 29 (1.9) wk and 1220 (412) g. Recordings were started 159 (77) s after birth. The inspiratory pattern and duration was similar in all breaths at 0.36 (0.11) s. There were five expiratory patterns; most infants had more than one. In 79% of breaths expiratory duration (1.6 (1.1) s) was slowed or held by interruption or braking of expiratory flow. It was braked in 47% to a complete expiratory hold, in 22% by grunting or crying, and in 10% by slow or interrupted expiration. In 21% of the breaths, expiration was not interrupted and lasted 0.53 (0.13) s. Half of these breaths represented a panting pattern (rate >60 /min). Immediately after birth, most very preterm infants, treated with continuous positive airway pressure, frequently prolong their expiration by braking the expiratory flow. :

  10. Uptake and continuous use of copper intrauterine device in a cohort of HIV-positive women.

    PubMed

    Landolt, Nadia Kancheva; Phanuphak, Nittaya; Teeratakulpisarn, Nipat; Kriengsinyot, Rosalin; Ahluwalia, Jennisa; Pinyakorn, Suteeraporn; Chaithongwongwatthana, Surasith; Ananworanich, Jintanat

    2013-01-01

    Copper intrauterine device (IUD) is not commonly used in many countries, though it provides effective reversible contraception with no or minimal primary systemic side effects. We assessed its uptake and continuation of use among HIV-positive Thai women. Sixty-six of 322 women of reproductive age, whom we approached for the study, met the eligibility criteria. Sterilization (62%) was the main reason for failure to enroll. Twenty-nine of them (44%) underwent IUD insertion. Considering condom use sufficient for pregnancy prevention (12%) was the main reason among eligible women for the refusal to participate in the study. At six months, 54% of enrolled participants reported one or more side effects such as increased menstrual flow (43%), spotting (21%) and dysmenorrhea (11%). The continuation rate of IUD use was high (93%), in spite of the persistent non-systemic side effects. The study showed that copper IUD could be an acceptable contraceptive choice for Thai HIV-positive women. Easy access to the method in a setting linked with the HIV service, and education on IUD risks and benefits is needed to promote the use of IUD in addition to condoms as an effective contraceptive option in HIV-infected women.

  11. Bilateral parotitis in a patient under continuous positive airway pressure treatment.

    PubMed

    Abdullayev, Ruslan; Saral, Filiz Cosku; Kucukebe, Omer Burak; Sayiner, Hakan Sezgin; Bayraktar, Cem; Akgun, Sadik

    Many conditions such as bacterial and viral infectious diseases, mechanical obstruction due to air and calculi and drugs can cause parotitis. We present a case of unusual bilateral parotitis in a patient under non-invasive continuous positive airway pressure (CPAP) therapy for chronic obstructive pulmonary disease exacerbation in intensive care unit. A 36-year-old patient was admitted to intensive care unit with the diagnosis of chronic obstructive pulmonary disease exacerbation. Antibiotherapy, bronchodilator therapy and non-invasive positive pressure ventilation were applied as treatment regimen. Painless swellings developed on the 3rd day of admission on the right and a day after this on the left parotid glands. Amylase levels were increased and ultrasonographic evaluation revealed bilateral parotitis. No intervention was made and the therapy was continued. The patient was discharged on the 6th day with clinical improvement and regression of parotid swellings without any complications. Parotitis may have occurred after retrograde air flow in the Stensen duct during CPAP application. After the exclusion of possible viral and bacteriological etiologies and possible drug reactions we can focus on this diagnosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  12. Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

    SciTech Connect

    Stevens, M. Tynan R.; Parsons, Dave D.; Robar, James L.

    2016-05-15

    Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three

  13. Continuous positive airway pressure treatment for acute mountain sickness at 4240 m in the Nepal Himalaya.

    PubMed

    Johnson, Pamela L; Johnson, Claire C; Poudyal, Prasanta; Regmi, Nirajan; Walmsley, Megan A; Basnyat, Buddha

    2013-09-01

    Acute mountain sickness (AMS) is very common at altitudes above 2500 m. There are few treatment options in the field where electricity availability is limited, and medical assistance or oxygen is unavailable or difficult to access. Positive airway pressure has been used to treat AMS at 3800 m. We hypothesized that continuous positive airway pressure (CPAP) could be used under field conditions powered by small rechargeable batteries. Methods Part 1. 5 subjects trekked to 3500 m from 2800 m in one day and slept there for one night, ascending in the late afternoon to 3840 m, where they slept using CPAP 6-7 cm via mask. The next morning they descended to 3500 m, spent the day there, ascended in late afternoon to 3840 m, and slept the night without CPAP. Continuous overnight oximetry was recorded and the Lake Louise questionnaire for AMS administered both mornings. Methods Part 2. 14 trekkers with symptoms of AMS were recruited at 4240 m. All took acetazolamide. The Lake Louise questionnaire was administered, oximetry recorded, and CPAP 6-7 cm was applied for 10-15 min. CPAP was used overnight and oximetry recorded continuously. In the morning the Lake Louise questionnaire was administered, and oximetry recorded for 10-15 min. The equipment used in both parts was heated, humidified Respironics RemStar® machines powered by Novuscell™ rechargeable lithium ion batteries. Oximetry was recorded using Embletta™ PDS. Results Part 1. CPAP improved overnight Sao2 and eliminated AMS symptoms in the one subject who developed AMS. CPAP was used for 7-9 h and the machines operated for >8 h using the battery. Results Part 2. CPAP use improved Sao2 when used for 10-15 min at the time of recruitment and overnight CPAP use resulted in significantly reduced AMS symptoms. Conclusion. CPAP with rechargeable battery may be a useful treatment option for trekkers and climbers who develop AMS.

  14. [A case of neurinoma of the nasal septum].

    PubMed

    Sakamoto, Kikuo; Gondo, Kyujiro; Tomita, Kazuhide; Kasuya, Takao

    2003-05-01

    Neurinoma grows in the modulated nerve with Schwann cells, and is observed for all positions of the body. It is comparatively rare for neurinoma to grow in the nasal cavity and paranasal sinuses, however. We report a case of neurinoma of the nasal septum. A 24-year-old man seen for nasal obstruction was found in anterior rhinoscopy to have a tumor of the bilateral nasal cavity. Computed tomography (CT) showed a soft tissue density mass in the anterior part of the nasal cavity. Because we suspected neurinoma from biopsy, we resected the tumor by Denker's operation under general anesthesia. We found that it originated from the nasal septum. Histopathological findings of the tumor indicated an Antoni A type neurinoma. After surgery, cartilago costalis was transplanted the plastic surgery to correct the defect in the nasal septum. The post operative course was good and no signs of recurrence were seen. This is the 19th case found in the literature.

  15. Impact of treatment with continuous positive airway pressure (CPAP) on weight in obstructive sleep apnea.

    PubMed

    Quan, Stuart F; Budhiraja, Rohit; Clarke, Denise P; Goodwin, James L; Gottlieb, Daniel J; Nichols, Deborah A; Simon, Richard D; Smith, Terry W; Walsh, James K; Kushida, Clete A

    2013-10-15

    To determine the impact of continuous positive airway pressure (CPAP) on weight change in persons with obstructive sleep apnea (OSA). The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blinded sham-controlled multicenter clinical trial conducted at 5 sites in the United States. Of 1,105 participants with an apnea hypopnea index ≥ 10 events/ hour initially randomized, 812 had body weight measured at baseline and after 6 months of study. CPAP or Sham CPAP. Body weight, height, hours of CPAP or Sham CPAP use, Epworth Sleepiness Scale score. Participants randomized to CPAP gained 0.35 ± 5.01 kg, whereas those on Sham CPAP lost 0.70 ± 4.03 kg (mean ± SD, p = 0.001). Amount of weight gain with CPAP was related to hours of device adherence, with each hour per night of use predicting a 0.42 kg increase in weight. This association was not noted in the Sham CPAP group. CPAP participants who used their device ≥ 4 h per night on ≥ 70% of nights gained the most weight over 6 months in comparison to non-adherent CPAP participants (1.0 ± 5.3 vs. -0.3 ± 5.0 kg, p = 0.014). OSA patients using CPAP may gain a modest amount of weight with the greatest weight gain found in those most compliant with CPAP. A commentary on this article appears in this issue on page 995. Quan SF; Budhiraja R; Clarke DP; Goodwin JL; Gottlieb DJ; Nichols DA; Simon RD; Smith TW; Walsh JK; Kushida CA. Impact of treatment with continuous positive airway pressure (CPAP) on weight in obstructive sleep apnea.

  16. Impact of Treatment with Continuous Positive Airway Pressure (CPAP) on Weight in Obstructive Sleep Apnea

    PubMed Central

    Quan, Stuart F.; Budhiraja, Rohit; Clarke, Denise P.; Goodwin, James L.; Gottlieb, Daniel J.; Nichols, Deborah A.; Simon, Richard D.; Smith, Terry W.; Walsh, James K.; Kushida, Clete A.

    2013-01-01

    Study Objective: To determine the impact of continuous positive airway pressure (CPAP) on weight change in persons with obstructive sleep apnea (OSA). Design, Setting, and Participants: The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blinded sham-controlled multicenter clinical trial conducted at 5 sites in the United States. Of 1,105 participants with an apnea hypopnea index ≥ 10 events/ hour initially randomized, 812 had body weight measured at baseline and after 6 months of study. Intervention: CPAP or Sham CPAP. Measurements: Body weight, height, hours of CPAP or Sham CPAP use, Epworth Sleepiness Scale score. Results: Participants randomized to CPAP gained 0.35 ± 5.01 kg, whereas those on Sham CPAP lost 0.70 ± 4.03 kg (mean ± SD, p = 0.001). Amount of weight gain with CPAP was related to hours of device adherence, with each hour per night of use predicting a 0.42 kg increase in weight. This association was not noted in the Sham CPAP group. CPAP participants who used their device ≥ 4 h per night on ≥ 70% of nights gained the most weight over 6 months in comparison to non-adherent CPAP participants (1.0 ± 5.3 vs. -0.3 ± 5.0 kg, p = 0.014). Conclusions: OSA patients using CPAP may gain a modest amount of weight with the greatest weight gain found in those most compliant with CPAP. Commentary: A commentary on this article appears in this issue on page 995. Citation: Quan SF; Budhiraja R; Clarke DP; Goodwin JL; Gottlieb DJ; Nichols DA; Simon RD; Smith TW; Walsh JK; Kushida CA. Impact of treatment with continuous positive airway pressure (CPAP) on weight in obstructive sleep apnea. J Clin Sleep Med 2013;9(10):989-993. PMID:24127141

  17. Increased dead space in face mask continuous positive airway pressure in neonates.

    PubMed

    Hishikawa, Kenji; Fujinaga, Hideshi; Ito, Yushi

    2017-01-01

    Continuous positive airway pressure (CPAP) by face mask is commonly performed in newborn resuscitation. We evaluated the effect of face mask CPAP on system dead space. Face mask CPAP increases dead space. A CPAP model study. We estimated the volume of the inner space of the mask. We devised a face mask CPAP model, in which the outlet of the mask was covered with plastic; and three modified face mask CPAP models, in which holes were drilled near to the cushion of the covered face mask to alter the air exit. We passed a continuous flow of 21% oxygen through each model and we controlled the inner pressure to 5 cmH2 O by adjusting the flow-relief valve. To evaluate the ventilation in the inner space of each model, we measured the oxygen concentration rise time, that is, the time needed for the oxygen concentration of each model to reach 35% after the oxygen concentration of the continuous flow was raised from 21% to 40%. The volume of inner space of the face mask was 38.3 ml. Oxygen concentration rise time in the face mask CPAP model was significantly longer at various continuous flow rates and points of the inner space of the face mask compared with that of the modified face mask CPAP model. Our study indicates that face mask CPAP leads to an increase in dead space and a decrease in ventilation efficiency under certain circumstances. Pediatr Pulmonol. 2017;52:107-111. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. [Nasal fractures in adults].

    PubMed

    Sjöstedt, Sannia; Larsen, Christian Grønhøj; Bilde, Anders; von Buchwald, Christian

    2016-03-07

    The risk of complications warrants treatment of most dislocated nasal fractures. Other injuries including other facial fractures and septal haematoma must be treated if present at the initial presentation. The usual treatment for a simple nasal fracture is closed reduction in local anaesthesia after five to seven days. Complicated cases require open reduction in general anaesthesia. Later revision of the deviated nose may become necessary in patients suffering from complications such as persistent nasal stenosis and/or deformity.

  19. A New Animal Model of Obstructive Sleep Apnea Responding to Continuous Positive Airway Pressure

    PubMed Central

    Neuzeret, Pierre-Charles; Gormand, Frédéric; Reix, Philippe; Parrot, Sandrine; Sastre, Jean-Pierre; Buda, Colette; Guidon, Gérard; Sakai, Kazuya; Lin, Jian-Sheng

    2011-01-01

    Study Objectives: An improved animal model of obstructive sleep apnea (OSA) is needed for the development of effective pharmacotherapies. In humans, flexion of the neck and a supine position, two main pathogenic factors during human sleep, are associated with substantially greater OSA severity. We postulated that these two factors might generate OSA in animals. Design: We developed a restraining device for conditioning to investigate the effect of the combination of 2 body positions—prone (P) or supine (S)—and 2 head positions—with the neck flexed at right angles to the body (90°) or in extension in line with the body (180°)—during sleep in 6 cats. Polysomnography was performed twice on each cat in each of the 4 sleeping positions—P180, S180, P90, or S90. The effect of continuous positive airway pressure (CPAP) treatment was then investigated in 2 cats under the most pathogenic condition. Setting: NA. Patients or Participants: NA. Interventions: NA. Measurements and Results: Positions P180 and, S90 resulted, respectively, in the lowest and highest apnea-hypopnea index (AHI) (3 ± 1 vs 25 ± 2, P < 0.001), while P90 (18 ± 3, P < 0.001) and S180 (13 ± 5, P < 0.01) gave intermediate values. In position S90, an increase in slow wave sleep stage 1 (28% ± 3% vs 22% ± 3%, P < 0.05) and a decrease in REM sleep (10% ± 2% vs 18% ± 2%, P < 0.001) were also observed. CPAP resulted in a reduction in the AHI (8 ± 1 vs 27 ± 3, P < 0.01), with the added benefit of sleep consolidation. Conclusion: By mimicking human pathogenic sleep conditions, we have developed a new reversible animal model of OSA. Citation: Neuzeret PC; Gormand F; Reix P; Parrot S; Sastre JP; Buda C; Guidon G; Sakai K; Lin JS. A new animal model of obstructive sleep apnea responding to continuous positive airway pressure. SLEEP 2011;34(4):541-548. PMID:21461333

  20. A high-value, low-cost bubble continuous positive airway pressure system for low-resource settings: technical assessment and initial case reports.

    PubMed

    Brown, Jocelyn; Machen, Heather; Kawaza, Kondwani; Mwanza, Zondiwe; Iniguez, Suzanne; Lang, Hans; Gest, Alfred; Kennedy, Neil; Miros, Robert; Richards-Kortum, Rebecca; Molyneux, Elizabeth; Oden, Maria

    2013-01-01

    Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design--consumer-grade pumps, medical tubing, and regulators--it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.

  1. A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports

    PubMed Central

    Brown, Jocelyn; Machen, Heather; Kawaza, Kondwani; Mwanza, Zondiwe; Iniguez, Suzanne; Lang, Hans; Gest, Alfred; Kennedy, Neil; Miros, Robert; Richards-Kortum, Rebecca; Molyneux, Elizabeth; Oden, Maria

    2013-01-01

    Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device. PMID:23372661

  2. Retrograde air escape via the nasolacrimal system: a previously unrecognized complication of continuous positive airway pressure in the management of obstructive sleep apnea.

    PubMed

    Singh, Narinder Pal; Walker, Robbie James Eades; Cowan, Fiona; Davidson, Arthur Craig; Roberts, David Newton

    2014-05-01

    Continuous positive airway pressure (CPAP) is the gold standard treatment for moderate to severe obstructive sleep apnoea (OSA). Eye-related side effects of CPAP are commonly attributed to a poorly sealed mask, allowing leaked air to blow over the eye. We present 3 cases where attended polysomnography (A-PSG) demonstrated CPAP-associated retrograde air escape via the nasolacrimal system (CRANS) in the absence of any mask leaks. Symptoms included dry eye, epiphora, air escape from the medial canthus, and eyelid flutter. Symptoms were controlled with a variety of surgical and nonsurgical techniques. CRANS represents a previously undescribed clinical entity. CRANS may be responsible for some CPAP-related eye side effects and possibly for rarer secondary eye complications, including conjunctivitis and corneal ulceration. CRANS should be suspected in any patient on CPAP complaining of eye symptoms. CRANS may be diagnosed through careful observation during A-PSG and confirmed by performing a "saline bubble test." Management options include nonsurgical (mask alternatives, humidification, nasopharyngeal airway) and surgical techniques (nasal airway surgery, inferior turbinate out-fracture and adhesion, injection of bulking agent around Hasner's valve).

  3. Automatic detection of position and depth of potential UXO using continuous wavelet transforms

    NASA Astrophysics Data System (ADS)

    Billings, Stephen D.; Herrmann, Felix J.

    2003-09-01

    Inversion algorithms for UXO discrimination using magnetometery have recently been used to achieve very low False Alarm Rates, with 100% recovery of detected ordnance. When there are many UXO and/or when the UXO are at significantly different depths, manual estimation of the initial position and scale for each item, is a laborious and time-consuming process. In this paper, we utilize the multi-resolution properties of wavelets to automatically estimate both the position and scale of dipole peaks. The Automated Wavelet Detection (AWD) algorithm that we develop consists of four-stages: (i) maxima and minima in the data are followed across multiple scales as we zoom with a continuous wavelet transform; (ii) the decay of the amplitude of each peak with scale is used to estimate the depth to source; (iii) adjacent maxima and minima of comparable depth are joined together to form dipole anomalies; and (iv) the relative positions and amplitudes of the extrema, along with their depths, are used to estimate a dipole model. We demonstrate the application of the AWD algorithm to three datasets with different characteristics. In each case, the method rapidly located the majority of dipole anomalies and produced accurate estimates of dipole parameters.

  4. Positioning Continuing Education: Boundaries and Intersections between the Domains Continuing Education, Knowledge Translation, Patient Safety and Quality Improvement

    ERIC Educational Resources Information Center

    Kitto, Simon; Bell, Mary; Peller, Jennifer; Sargeant, Joan; Etchells, Edward; Reeves, Scott; Silver, Ivan

    2013-01-01

    Public and professional concern about health care quality, safety and efficiency is growing. Continuing education, knowledge translation, patient safety and quality improvement have made concerted efforts to address these issues. However, a coordinated and integrated effort across these domains is lacking. This article explores and discusses the…

  5. Positioning Continuing Education: Boundaries and Intersections between the Domains Continuing Education, Knowledge Translation, Patient Safety and Quality Improvement

    ERIC Educational Resources Information Center

    Kitto, Simon; Bell, Mary; Peller, Jennifer; Sargeant, Joan; Etchells, Edward; Reeves, Scott; Silver, Ivan

    2013-01-01

    Public and professional concern about health care quality, safety and efficiency is growing. Continuing education, knowledge translation, patient safety and quality improvement have made concerted efforts to address these issues. However, a coordinated and integrated effort across these domains is lacking. This article explores and discusses the…

  6. The supernumerary nasal tooth.

    PubMed

    Kirmeier, R; Truschnegg, A; Payer, M; Malyk, J; Daghighi, S; Jakse, N

    2009-11-01

    Teeth exceeding the normal dental complement that have erupted into the nasal cavity are a rare pathological entity. This case report describes a female patient with recurrent complaints and fetid discharge from the left nasal cavity. The suspected clinical diagnosis of a supernumerary nasal tooth was confirmed by computed tomography. After endoscopic removal, the tooth was examined using X-ray microtomography and thin-section preparations; these findings are presented for the first time. A literature search identified 25 supernumerary nasal teeth in 23 patients.

  7. Pathogenesis of nasal polyposis

    PubMed Central

    Hulse, K. E.; Stevens, W. W.; Tan, B. K.; Schleimer, R. P.

    2015-01-01

    Summary Chronic rhinosinusitis with nasal polyps (CRSwNP) is a complex inflammatory condition that affects a large proportion of the population world-wide and is associated with high cost of management and significant morbidity. Yet, there is a lack of population-based epidemiologic studies using current definitions of CRSwNP, and the mechanisms that drive pathogenesis in this disease remain unclear. In this review, we summarize the current evidence for the plethora of factors that likely contribute to CRSwNP pathogenesis. Defects in the innate function of the airway epithelial barrier, including diminished expression of antimicrobial products and loss of barrier integrity, combined with colonization by fungi and bacteria likely play a critical role in the development of chronic inflammation in CRSwNP. This chronic inflammation is characterized by elevated expression of many key inflammatory cytokines and chemokines, including IL-5, thymic stromal lymphopoietin and CCL11, that help to initiate and perpetuate this chronic inflammatory response. Together, these factors likely combine to drive the influx of a variety of immune cells, including eosinophils, mast cells, group 2 innate lymphoid cells and lymphocytes, which participate in the chronic inflammatory response within the nasal polyps. Importantly, however, future studies are needed to demonstrate the necessity and sufficiency of these potential drivers of disease in CRSwNP. In addition to the development of new tools and models to aid mechanistic studies, the field of CRSwNP research also needs the type of robust epidemiologic data that has served the asthma community so well. Given the high prevalence, costs and morbidity, there is a great need for continued research into CRS that could facilitate the development of novel therapeutic strategies to improve treatment for patients who suffer from this disease. PMID:25482020

  8. [Model of nasal cavity and paranasal sinuses created for studying the dynamics of the nasal airflow].

    PubMed

    Jiang, Guang-Li; Xu, Geng

    2008-09-01

    To create a model from an adult cadaver's nasal cavity and verify whether it can be used to study the airflow dynamics in the nasal cavity and paranasal sinuses. (1) The model was made by the material of transparent resin and Bengal gelatin according to a nasal cast of a cadaver. (2) The model was check by Acoustic Rhino-meter, CT scan and nasal endoscope, then compared with the normal. (3) To observe the smoke flow in the model and record it by a digital camera It was succeeded in creating a model of the nasal cavity and paranasal sinus. The model was good at simulation and transparency. The structure of the model, the cross-sectional areas of the nasal passage and the CT scan results of the model were similar to the normal. The airflows in the model could be recorded by a digital camera. It showed that there were two types of airflows in the nose. The majority of airflows were found in the common and middle nasal meatus, the little part of the airflows passed through the upper of the nose like a parabola. There was an increasing proportion of airflows in the olfactory region when elevated the airflow rates. A relatively large vortex formed in the upper part of the nose, just behind the nasal valve, and another one was in the pharynx nasals. (1) The transparent resin and Bengal gelatin are suitable for making the model of the nose. The model can be used to study the airflows dynamics of the nasal cavity and paranasal sinuses. (2) The majority of inspired airflows go straightly to the pharynx nasals through the combined middle and inferior airways, a little part of inspired airflows through the olfactory region like a parabola. (3) The inspired airflows first arrived at the front position of the middle and inferior turbinate. The airflows can go into the maxillary sinus, a vortex can be see in the maxillary sinus during breath.

  9. The Emergence of Central Sleep Apnea after Surgical Relief of Nasal Obstruction in Obstructive Sleep Apnea

    PubMed Central

    Goldstein, Cathy; Kuzniar, Tomasz J.

    2012-01-01

    By the current definition, complex sleep apnea (CompSA) refers to the emergence of central sleep apnea (CSA) during the treatment of obstructive sleep apnea (OSA) with continuous positive airway pressure (CPAP). However, new-onset CSA has been described with use of other treatments for OSA, including tracheostomy, maxillofacial surgery, and mandibular advancement device. We present a patient with CSA beginning after endoscopic sinus and nasal surgery for nasal obstruction in the setting of mild OSA. This case highlights the importance of non-PAP mechanisms in the pathogenesis of CompSA. Citation: Goldstein C; Kuzniar TJ. The emergence of central sleep apnea after surgical relief of nasal obstruction in obstructive sleep apnea. J Clin Sleep Med 2012;8(3):321-322. PMID:22701391

  10. Nonexistence of entangled continuous-variable Werner states with positive partial transpose

    NASA Astrophysics Data System (ADS)

    McNulty, Daniel; Tatham, Richard; Mišta, Ladislav

    2014-03-01

    We address an open question about the existence of entangled continuous-variable (CV) Werner states with positive partial transpose (PPT). We prove that no such state exists by showing that all PPT CV Werner states are separable. The separability follows by observing that these CV Werner states can be approximated by truncating the states into a finite-dimensional convex mixture of product states. In addition, the constituents of the product states comprise a generalized non-Gaussian measurement which gives, rather surprisingly, a strictly tighter upper bound on quantum discord than photon counting. These results uncover the presence of only negative partial transpose entanglement and illustrate the complexity of more general nonclassical correlations in this paradigmatic class of genuine non-Gaussian quantum states.

  11. Efficiency of cold passover and heated humidification under continuous positive airway pressure.

    PubMed

    Randerath, W J; Meier, J; Genger, H; Domanski, U; Rühle, K H

    2002-07-01

    Cold passover and heated humidifiers are employed for the prevention of side-effects associated with continuous positive airway pressure (CPAP) treatment. However, to date, it has not been possible to separately measure the humidity of inspired and expired air. The aim of this study was to compare the relative humidity of the inspired air and the water loss during respiration between cold passover and heated humidifiers under CPAP. Humidity and temperature were determined separately for the respiratory phases, without humidification, with cold passover and heated humidifiers in 10 healthy subjects. Humidity was measured with a capacitive hygrometer, temperature with a "Type K" thermosensor, and impedance of the total respiratory system with impulse oscillometry. The relative humidity (rH) of the inspired air (mean+/-SD) increased significantly from 24.0+/-9.1%, rH (34.8+/-1.0 degrees C, no humidifier) to 34.5+/-10.1%, rH (34.6+/-1.0 degrees C) under cold humidification, and to 53.9+/-13.2% rH (35.0+/-1.1 degrees C) under heated humidification. With heated humidification, water loss was reduced by 38% compared to cold humidification. The impedance increased from 5.7+/-1.8 cmH2O x L x s(-1) (no humidifier) to 6.7+/-1.8 cmH2O x L x s(-1) (heated humidifier). The authors conclude that the use of a heated humidifier during continuous positive airway pressure appreciably increases the relative humidity of the inspired air and reduces the water loss during respiration.

  12. Aerophagia and Gastroesophageal Reflux Disease in Patients using Continuous Positive Airway Pressure: A Preliminary Observation

    PubMed Central

    Watson, Nathaniel F.; Mystkowski, Sue K.

    2008-01-01

    Study Objectives: Aerophagia is a complication of continuous positive airway pressure (CPAP) therapy for sleep disordered breathing (SDB), whereupon air is forced into the stomach and bowel. Associated discomfort can result in CPAP discontinuation. We hypothesize that aerophagia is associated with gastroesophageal reflux disease (GERD) via mechanisms involving GERD related lower esophageal sphincter (LES) compromise. Methods: Twenty-two subjects with aerophagia and 22 controls, matched for age, gender, and body mass index, who were being treated with CPAP for SDB were compared in regard to clinical aspects of GERD, GERD associated habits, SDB severity as measured by polysomnography, and mean CPAP pressure. Results: More subjects with aerophagia had symptoms of GERD (77.3% vs. 36.4%; p < 0.01) and were on GERD related medications (45.5% vs. 18.2%, p < 0.05) than controls. Regarding polysomnography, mean oxygen saturation percentages were lower in the aerophagia group than controls (95.0% vs. 96.5%, p < 0.05). No other differences were observed, including mean CPAP pressures. No one in the aerophagia group (vs. 27.3% of the control group) was a current tobacco user (p < 0.01). There was no difference in caffeine or alcohol use between the 2 groups. Conclusions: These results imply aerophagia is associated with GERD symptoms and GERD related medication use. This finding suggests a relationship between GERD related LES pathophysiology and the development of aerophagia in patients with SDB treated with CPAP. Citation: Watson NF; Mystkowski SK. Aerophagia and gastroesophageal reflux disease in patients using continuous positive airway pressure: a preliminary observation. J Clin Sleep Med 2008;4(5):434–438. PMID:18853700

  13. Continuous positive airway pressure therapy in obstuctive sleep apnea: benefits and alternatives.

    PubMed

    Cao, Michelle T; Sternbach, Joshua M; Guilleminault, C

    2017-04-01

    Obstructive sleep apnea (OSA) is a highly prevalent condition affecting persons of all age with an increasing public health burden. It is implicated in cardiovascular disease, metabolic syndrome, neurocognitive impairment, reductions in quality of life, and increased motor vehicle accidents. The goals of OSA treatment are to improve sleep and daytime symptoms, and minimize cardiovascular risks.Areas covered: Continuous positive airway pressure (CPAP) is considered the gold standard therapy that delivers pressurized air into the upper airway to relieve obstruction during sleep. Although CPAP is an effective modality of treatment for OSA, adherence to therapy is highly variable. This article highlights the benefits of CPAP therapy, along with alternative treatment options including oral appliance, implantable and wearable devices, and surgery. Expert commentary: CPAP therapy is the gold standard treatment option and should continue to be offered to those who suffer from OSA. Alternative options are available for those who are unable to adhere to CPAP or choose an alternative treatment modality. The most interesting advances have been incorporating orthodontic procedures in conjunction with myofunctional therapy in prepubertal children, raising the possibility of OSA prevention by initiating treatment early in life.

  14. Toxicology of the nasal passages

    SciTech Connect

    Barrow, C.S.

    1986-01-01

    Contents of this work include: Comparative Anatomy and Function of the Nasal Passages; Light Microscopic Examination of the Rat Nasal Passages: Preparation and Morphologic Features; Histopathology of Acute and Subacute Nasal Toxicity; Pathology of Chronic Nasal Toxic Responses Including Cancer; Responses of the Nasal Mucociliary Apparatus to Airborne Irritants; Effects of Chemical Exposure on Olfaction in Humans, Possible Consequences of Cytochrome P-450-Dependent Monooxygenases in Nasal Tissues.

  15. Positional stability of electromagnetic transponders used for prostate localization and continuous, real-time tracking.

    PubMed

    Litzenberg, Dale W; Willoughby, Twyla R; Balter, James M; Sandler, Howard M; Wei, John; Kupelian, Patrick A; Cunningham, Alexis A; Bock, Andrea; Aubin, Michele; Roach, Mack; Shinohara, Katsuto; Pouliot, Jean

    2007-07-15

    To determine the relative positional stability of implanted glass-encapsulated circuits (transponders) used in continuous electromagnetic localization and tracking of target volumes during radiation therapy. Ideally, the distances between transponders remains constant over the course of treatment. In this work, we evaluate the accuracy of these conditions. Three transponders were implanted in each of 20 patients. Images (CT scan or X-ray pair) were acquired at 13 time points. These images occurred from the day of implant (2 weeks before simulation) to 4 weeks posttreatment. The distance between transponders was determined from each dataset. The average and standard deviation of each distance were determined, and changes were evaluated over several time periods, including pretreatment and during therapy. Of 60 transponders implanted, 58 showed no significant migration from their intended positions. Of the two transponders that did migrate, one appears to have been implanted in the venous plexus, and the other in the urethra, with no clinical consequences to the patients. An analysis that included the planning CT scan and all subsequent distance measurements showed that the standard deviation of intertransponder distances was < or =1.2 mm for up to 1 month after the completion of therapy. Implanted transponders demonstrate the same long-term stability characteristics as implanted gold markers, within statistical uncertainties. As with gold markers, and using the same implant procedure, basic guidelines for the placement of transponders within the prostate help ensure minimal migration.

  16. Modeling and Implementation of Multi-Position Non-Continuous Rotation Gyroscope North Finder

    PubMed Central

    Luo, Jun; Wang, Zhiqian; Shen, Chengwu; Kuijper, Arjan; Wen, Zhuoman; Liu, Shaojin

    2016-01-01

    Even when the Global Positioning System (GPS) signal is blocked, a rate gyroscope (gyro) north finder is capable of providing the required azimuth reference information to a certain extent. In order to measure the azimuth between the observer and the north direction very accurately, we propose a multi-position non-continuous rotation gyro north finding scheme. Our new generalized mathematical model analyzes the elements that affect the azimuth measurement precision and can thus provide high precision azimuth reference information. Based on the gyro’s principle of detecting a projection of the earth rotation rate on its sensitive axis and the proposed north finding scheme, we are able to deduct an accurate mathematical model of the gyro outputs against azimuth with the gyro and shaft misalignments. Combining the gyro outputs model and the theory of propagation of uncertainty, some approaches to optimize north finding are provided, including reducing the gyro bias error, constraining the gyro random error, increasing the number of rotation points, improving rotation angle measurement precision, decreasing the gyro and the shaft misalignment angles. According them, a north finder setup is built and the azimuth uncertainty of 18” is obtained. This paper provides systematic theory for analyzing the details of the gyro north finder scheme from simulation to implementation. The proposed theory can guide both applied researchers in academia and advanced practitioners in industry for designing high precision robust north finder based on different types of rate gyroscopes. PMID:27657067

  17. Continuous separation of multiple particles by negative and positive dielectrophoresis in a modified H-filter.

    PubMed

    Lewpiriyawong, Nuttawut; Yang, Chun

    2014-03-01

    The article presents a new application of the modified H-filter with insulating rectangular blocks using negative and positive DEP for separation of multiple particles in a continuous pressure-driven flow. The multiple insulating blocks fabricated along the main channel induce spatially nonuniform electric fields which exert differential repulsive (negative) or attractive (positive) DEP forces on particles, depending on the size and the polarizability of particles relative to their suspending medium. As a result, particles of different sizes and polarizability can be separated into different outlets of the H-filter. Numerical simulations are also performed to analyze the effects of block gap and width on electric field distribution and DEP force characteristics near the insulating blocks so as to provide design guidelines for optimal structural dimensions of the microfluidic device. The device performance is demonstrated by separating a three-sized particles mixture, including 2 μm fluorescent particles with an attractive DEP force and both 5 and 10 μm nonfluorescent particles with differential repulsive DEP forces. High separation rate of 99% is successfully achieved. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Modeling and Implementation of Multi-Position Non-Continuous Rotation Gyroscope North Finder.

    PubMed

    Luo, Jun; Wang, Zhiqian; Shen, Chengwu; Kuijper, Arjan; Wen, Zhuoman; Liu, Shaojin

    2016-09-20

    Even when the Global Positioning System (GPS) signal is blocked, a rate gyroscope (gyro) north finder is capable of providing the required azimuth reference information to a certain extent. In order to measure the azimuth between the observer and the north direction very accurately, we propose a multi-position non-continuous rotation gyro north finding scheme. Our new generalized mathematical model analyzes the elements that affect the azimuth measurement precision and can thus provide high precision azimuth reference information. Based on the gyro's principle of detecting a projection of the earth rotation rate on its sensitive axis and the proposed north finding scheme, we are able to deduct an accurate mathematical model of the gyro outputs against azimuth with the gyro and shaft misalignments. Combining the gyro outputs model and the theory of propagation of uncertainty, some approaches to optimize north finding are provided, including reducing the gyro bias error, constraining the gyro random error, increasing the number of rotation points, improving rotation angle measurement precision, decreasing the gyro and the shaft misalignment angles. According them, a north finder setup is built and the azimuth uncertainty of 18" is obtained. This paper provides systematic theory for analyzing the details of the gyro north finder scheme from simulation to implementation. The proposed theory can guide both applied researchers in academia and advanced practitioners in industry for designing high precision robust north finder based on different types of rate gyroscopes.

  19. The role of nasal allergy in chronic secretory otitis media.

    PubMed

    Pelikan, Zdenek

    2007-11-01

    Chronic secretory otitis media (SOM) has multifactorial causes, and nasal allergy is suspected as one of these causative factors. To investigate the possible role of nasal allergy in SOM in adults and to determine the diagnostic value of nasal challenges with allergens (nasal provocation tests) combined with tympanometry for the diagnosis of this disorder. In 69 young adults with chronic or recurrent SOM, 173 nasal challenges with allergens were performed by anterior rhinomanometry combined with tympanometry (pure-tone air conduction tympanometry). In 42 control subjects with only allergic rhinitis and no history of middle ear disease, 42 nasal challenges with allergens were repeated and combined with tympanometry. The study design was a placebo-controlled comparison. Of the 69 patients, 54 developed 129 positive nasal responses of various types (P < .01), 117 of which were accompanied by significant changes in middle ear pressure (P < .01). No significant tympanometric changes (P > .10) were recorded during the 42 positive nasal responses in control subjects. These results may confirm the occurrence of chronic SOM in some adult patients and the possible involvement of nasal allergy in chronic SOM. The nasal challenges with allergen performed by rhinomanometry, combined with tympanometry, seem to be a valuable supplementary tool for the diagnosis of this disorder.

  20. Continuous positive airway pressure therapy for infants with respiratory distress in non tertiary care centers: a randomized, controlled trial.

    PubMed

    Buckmaster, Adam G; Arnolda, Gaston; Wright, Ian M R; Foster, Jann P; Henderson-Smart, David J

    2007-09-01

    Our objective was to determine whether continuous positive airway pressure therapy would safely reduce the need for up-transfer of infants with respiratory distress from nontertiary centers. We randomly assigned 300 infants at >30 weeks of gestation with respiratory distress to receive either Hudson prong bubble continuous positive airway pressure therapy or headbox oxygen treatment (standard care). The primary end point was "up-transfer or treatment failure." Secondary end points included death, length of nursery stay, time receiving oxygen therapy, cost of care, and other measures of morbidity. Of 151 infants who received continuous positive airway pressure therapy, 35 either were up-transferred or experienced treatment failure, as did 60 of the 149 infants given headbox oxygen treatment. There was no difference in the length of stay or the duration of oxygen treatment. For every 6 infants treated with continuous positive airway pressure therapy, there was an estimated cost saving of $10,000. Pneumothorax was identified for 14 infants in the continuous positive airway pressure group and 5 in the headbox group. There was no difference in any other measure of morbidity or death. Hudson prong bubble continuous positive airway pressure therapy reduces the need for up-transfer of infants with respiratory distress in nontertiary centers. There is a clinically relevant but not statistically significant increase in the risk of pneumothorax. There are significant benefits associated with continuous positive airway pressure use in larger nontertiary centers.

  1. Combination of constant-flow and continuous positive-pressure ventilation in canine pulmonary edema.

    PubMed

    Sznajder, J I; Becker, C J; Crawford, G P; Wood, L D

    1989-08-01

    Constant-flow ventilation (CFV) maintains alveolar ventilation without tidal excursion in dogs with normal lungs, but this ventilatory mode requires high CFV and bronchoscopic guidance for effective subcarinal placement of two inflow catheters. We designed a circuit that combines CFV with continuous positive-pressure ventilation (CPPV; CFV-CPPV), which negates the need for bronchoscopic positioning of CFV cannula, and tested this system in seven dogs having oleic acid-induced pulmonary edema. Addition of positive end-expiratory pressure (PEEP, 10 cmH2O) reduced venous admixture from 44 +/- 17 to 10.4 +/- 5.4% and kept arterial CO2 tension (PaCO2) normal. With the innovative CFV-CPPV circuit at the same PEEP and respiratory rate (RR), we were able to reduce tidal volume (VT) from 437 +/- 28 to 184 +/- 18 ml (P less than 0.001) and elastic end-inspiratory pressures (PEI) from 25.6 +/- 4.6 to 17.7 +/- 2.8 cmH2O (P less than 0.001) without adverse effects on cardiac output or pulmonary exchange of O2 or CO2; indeed, PaCO2 remained at 35 +/- 4 Torr even though CFV was delivered above the carina and at lower (1.6 l.kg-1.min-1) flows than usually required to maintain eucapnia during CFV alone. At the same PEEP and RR, reduction of VT in the CPPV mode without CFV resulted in CO2 retention (PaCO2 59 +/- 8 Torr). We conclude that CFV-CPPV allows CFV to effectively mix alveolar and dead spaces by a small bulk flow bypassing the zone of increased resistance to gas mixing, thereby allowing reduction of the CFV rate, VT, and PEI for adequate gas exchange.

  2. Changes in Energy Metabolism after Continuous Positive Airway Pressure for Obstructive Sleep Apnea.

    PubMed

    Tachikawa, Ryo; Ikeda, Kaori; Minami, Takuma; Matsumoto, Takeshi; Hamada, Satoshi; Murase, Kimihiko; Tanizawa, Kiminobu; Inouchi, Morito; Oga, Toru; Akamizu, Takashi; Mishima, Michiaki; Chin, Kazuo

    2016-09-15

    Disrupted energy homeostasis in obstructive sleep apnea (OSA) may lead to weight gain. Paradoxically, treating OSA with continuous positive airway pressure (CPAP) may also promote weight gain, although the underlying mechanism remains unclear. To explore the underlying mechanism by which patients with OSA gain weight after CPAP. A comprehensive assessment of energy metabolism was performed in 63 newly diagnosed OSA study participants (51 men; 60.8 ± 10.1 yr; apnea-hypopnea index >20 h(-1)) at baseline, CPAP initiation, and at a 3-month follow-up. Measurements included polysomnography, body weight, body composition, basal metabolic rate (BMR), hormones (norepinephrine, cortisol, leptin, ghrelin, insulin-like growth factor-1), dietary intake, eating behavior, and physical activity. BMR significantly decreased after CPAP (1,584 kcal/d at baseline, 1,561 kcal/d at CPAP initiation, and 1,508 kcal/d at follow-up; P < 0.001), whereas physical activity and total caloric intake did not significantly change. In multivariate regression, baseline apnea-hypopnea index, Δurine norepinephrine, and CPAP adherence were significant predictors of ΔBMR. The weight gainers had higher leptin levels, lower ghrelin levels, and higher eating behavior scores than the non-weight gainers, indicating a positive energy balance and disordered eating behavior among the weight gainers. Among the parameters related to energy metabolism, increased caloric intake was a particularly significant predictor of weight gain. Although a reduction in BMR after CPAP predisposes to a positive energy balance, dietary intake and eating behavior had greater impacts on weight change. These findings highlight the importance of lifestyle modifications combined with CPAP. Clinical trial registered with http://www.umin.ac.jp/english/ (UMIN000012639).

  3. Anterior rhinomanometry in nasal allergen challenges.

    PubMed

    Ferreira, M B; Carlos, A G

    1998-11-01

    Even simple and relatively safe provocation procedures like nasal allergen challenges, should aim to allow detection of positivity with the less possible discomfort to the patient. The objective of this work was to evaluate if the use of rhinomanometric measurements during nasal provocation procedures could allow a decrease in the total administered allergen dose, causing less symptoms to the patients but without increasing the number of false-negatives, comparatively to clinical scores or nasal peak-flow measurements. Our results showed that performing rhinomanometric measurements during nasal HDM challenge procedures can lead in many patients to a reduction in the total dose of allergen administered during the challenge, without loss of sensitivity or specificity. This allergen dose reduction translates in less time consumed during the provocation and less patients' discomfort.

  4. Nasality in Taiwanese

    ERIC Educational Resources Information Center

    Pan, Ho-hsien

    2004-01-01

    This study used perceptual and articulatory data to investigate a language specific phonemic inventory, and allophonic rules for homorganic initial voiced stops versus homorganic nasal stops, and oral versus nasal vowels in Taiwanese. Four experiments were conducted: concept formation, gating, and two airflow studies. Results of a first nasal…

  5. Nasality in Taiwanese

    ERIC Educational Resources Information Center

    Pan, Ho-hsien

    2004-01-01

    This study used perceptual and articulatory data to investigate a language specific phonemic inventory, and allophonic rules for homorganic initial voiced stops versus homorganic nasal stops, and oral versus nasal vowels in Taiwanese. Four experiments were conducted: concept formation, gating, and two airflow studies. Results of a first nasal…

  6. Lining in nasal reconstruction.

    PubMed

    Haack, Sebastian; Fischer, Helmut; Gubisch, Wolfgang

    2014-06-01

    Restoring nasal lining is one of the essential parts during reconstruction of full-thickness defects of the nose. Without a sufficient nasal lining the whole reconstruction will fail. Nasal lining has to sufficiently cover the shaping subsurface framework. But in addition, lining must not compromise or even block nasal ventilation. This article demonstrates different possibilities of lining reconstruction. The use of composite grafts for small rim defects is described. The limits and technical components for application of skin grafts are discussed. Then the advantages and limitations of endonasal, perinasal, and hingeover flaps are demonstrated. Strategies to restore lining with one or two forehead flaps are presented. Finally, the possibilities and technical aspects to reconstruct nasal lining with a forearm flap are demonstrated. Technical details are explained by intraoperative pictures. Clinical cases are shown to illustrate the different approaches and should help to understand the process of decision making. It is concluded that although the lining cannot be seen after reconstruction of the cover it remains one of the key components for nasal reconstruction. When dealing with full-thickness nasal defects, there is no way to avoid learning how to restore nasal lining.

  7. Nasal dermoid sinus cyst.

    PubMed

    Cauchois, R; Laccourreye, O; Bremond, D; Testud, R; Küffer, R; Monteil, J P

    1994-08-01

    Nasal dermoid sinus cyst is one of the diagnoses of midline nasal masses in children. This retrospective study analyzes the various theories regarding the origin of this congenital abnormality, the differential diagnosis, and the value of magnetic resonance imaging, as well as the various surgical options available.

  8. Nasal CPAP and weight loss in hypertensive patients with obstructive sleep apnoea.

    PubMed Central

    Rauscher, H; Formanek, D; Popp, W; Zwick, H

    1993-01-01

    BACKGROUND--The high prevalence of obstructive sleep apnoea (OSA) in patients with systemic hypertension and of hypertension in patients with OSA suggests a causal link between the two disorders. This study was carried out to determine whether nasal continuous positive airway pressure (CPAP) and weight loss affect daytime hypertension in OSA. METHODS--Sixty hypertensive patients with OSA took part in the study; 33 accepted nasal CPAP and used their machine for 5.7 (0.2) hours per night, and the remaining 27 patients refused nasal CPAP and upper airway surgery so the only therapeutic intervention was a recommendation of weight loss. A significant change in hypertension during follow up was defined as either a change in mean blood pressure of at least 10 mm Hg (or more than 8%) without a change in drug treatment, or a reduction in drug dosage with mean blood pressure within these limits. Weight loss was defined as a body mass index of at least 5% below the baseline value. RESULTS--After 512 (41) days, hypertension had become less severe in seven of 12 patients (58%) treated with weight loss only, in eight of 28 patients (29%) with nasal CPAP only, in two of five patients with nasal CPAP and weight loss, and in one of 15 patients without nasal CPAP or weight loss. Multivariate analysis of variance with the outcome of hypertension at follow up as the dependent variable revealed that only the percentage change in body mass index significantly contributed to the course of hypertension. CONCLUSION--The course of hypertension in OSA is more closely linked to weight loss than to elimination of sleep apnoea by nasal CPAP. PMID:8322241

  9. Nasal CPAP and weight loss in hypertensive patients with obstructive sleep apnoea.

    PubMed

    Rauscher, H; Formanek, D; Popp, W; Zwick, H

    1993-05-01

    The high prevalence of obstructive sleep apnoea (OSA) in patients with systemic hypertension and of hypertension in patients with OSA suggests a causal link between the two disorders. This study was carried out to determine whether nasal continuous positive airway pressure (CPAP) and weight loss affect daytime hypertension in OSA. Sixty hypertensive patients with OSA took part in the study; 33 accepted nasal CPAP and used their machine for 5.7 (0.2) hours per night, and the remaining 27 patients refused nasal CPAP and upper airway surgery so the only therapeutic intervention was a recommendation of weight loss. A significant change in hypertension during follow up was defined as either a change in mean blood pressure of at least 10 mm Hg (or more than 8%) without a change in drug treatment, or a reduction in drug dosage with mean blood pressure within these limits. Weight loss was defined as a body mass index of at least 5% below the baseline value. After 512 (41) days, hypertension had become less severe in seven of 12 patients (58%) treated with weight loss only, in eight of 28 patients (29%) with nasal CPAP only, in two of five patients with nasal CPAP and weight loss, and in one of 15 patients without nasal CPAP or weight loss. Multivariate analysis of variance with the outcome of hypertension at follow up as the dependent variable revealed that only the percentage change in body mass index significantly contributed to the course of hypertension. The course of hypertension in OSA is more closely linked to weight loss than to elimination of sleep apnoea by nasal CPAP.

  10. Long-term survival of patients with obstructive sleep apnea treated by uvulopalatopharyngoplasty or nasal CPAP.

    PubMed

    Keenan, S P; Burt, H; Ryan, C F; Fleetham, J A

    1994-01-01

    Patients with obstructive sleep apnea (OSA) have decreased long-term survival. Treatment of OSA with either nasal continuous positive airway pressure (CPAP) or tracheostomy improves survival, but the effect of uvulopalatopharyngoplasty (UPPP) on survival is unclear. We attempted to contact all patients with OSA treated with either UPPP or nasal CPAP over a 6-year period to compare long-term survival between these two treatments. One hundred fifty-four patients had a UPPP during this period. Five of these patients were later treated with nasal CPAP and were excluded from the analysis. Twelve of the remaining 149 were unavailable for follow-up but were included in the analysis. Follow-up polysomnography was performed on 140 (94 percent) of these patients; 114 (81 percent) had either a postoperative apnea index < 5/h or > 50 percent reduction in apnea index. Two hundred eight patients were started on a regimen of nasal CPAP during the same period. Eighty-two patients discontinued nasal CPAP therapy and were excluded from analysis. Nine of the remaining 126 were unavailable for follow-up but were included in the analysis. Six patients treated with UPPP died. Three of these six patients had a 3-month follow-up polysomnogram that revealed apnea indices of 1/h, 5/h, and 23/h. Three patients treated with nasal CPAP died. There was no difference in the long-term survival between the two treatment groups. We conclude that there may be no difference in the long-term survival of patients with OSA between those treated with UPPP and those treated with nasal CPAP. This study emphasizes the importance of follow-up polysomnography in all patients after UPPP.

  11. [Nasal allergenic provocation test].

    PubMed

    Becerril Angeles, M H; Pérez López, A; Azuara Pliego, E

    2000-01-01

    This is a method to evaluate both specific sensitivity to allergens in the nasal mucosa, IgE-mediated hypersensitivity, and antiinflammatory and antiallergic drugs efficacy, whose objectives are for research in diagnosis and treatment. The method is based in allergen extracts delivery in the nasal mucosa and the post-challenge measurement of rhinitis symptoms, vasoactive mediators release quantification and nasal obstruction degree evaluated by rhinomanometry. Nasal allergen challenge is a procedure of diagnostic and therapeutic evaluation usefulness, that must be performed in selected patients, in adequate facilities, by experts physicians, with standardised allergen dosages, in an specific nasal area, with objective measurements (rhinomanometry, mediators and secretions of the allergic response) and symptoms scoring that allow get reliable results in patients with allergic rhinitis under study.

  12. Nanoparticles for nasal vaccination.

    PubMed

    Csaba, Noemi; Garcia-Fuentes, Marcos; Alonso, Maria Jose

    2009-02-27

    The great interest in mucosal vaccine delivery arises from the fact that mucosal surfaces represent the major site of entry for many pathogens. Among other mucosal sites, nasal delivery is especially attractive for immunization, as the nasal epithelium is characterized by relatively high permeability, low enzymatic activity and by the presence of an important number of immunocompetent cells. In addition to these advantageous characteristics, the nasal route could offer simplified and more cost-effective protocols for vaccination with improved patient compliance. The use of nanocarriers provides a suitable way for the nasal delivery of antigenic molecules. Besides improved protection and facilitated transport of the antigen, nanoparticulate delivery systems could also provide more effective antigen recognition by immune cells. These represent key factors in the optimal processing and presentation of the antigen, and therefore in the subsequent development of a suitable immune response. In this sense, the design of optimized vaccine nanocarriers offers a promising way for nasal mucosal vaccination.

  13. Continuous Positive Airway Pressure and Breathlessness in Obese Patients with Obstructive Sleep Apnea: A Pilot Study

    PubMed Central

    Xiao, Sichang; Bastianpillai, Johan; Ratneswaran, Culadeeban; Pengo, Martino F.; Luo, Yuanming; Jolley, Caroline J.; Moxham, John; Steier, Joerg

    2016-01-01

    Study Objectives: Continuous positive airway pressure (CPAP) is an effective treatment for obstructive sleep apnea (OSA). However, long-term compliance with CPAP is limited. We tested the hypothesis that CPAP levels routinely used during sleep increase neural respiratory drive (NRD) and breathlessness, which may discourage compliance. Methods: This was an observational physiological cohort study in a respiratory physiology and sleep unit, University Hospital. Patients with a body mass index (BMI) > 25 kg/m2 and confirmed OSA were studied supine and awake on CPAP (4–20 cm H2O, increments of 2 cm H2O/3 min). We measured NRD during awake CPAP titration in obese subjects to quantify the response to the load of the respiratory system and compared it to the CPAP used for nocturnal treatment, with the modified Borg Scale (mBorg) for dyspnea recorded (from 0 to 10 points, with higher numbers indicating more breathlessness). Results: Fifteen patients (age 48 ± 10 years, 12 male, BMI 38.9 ± 5.8 kg/m2) with OSA (AHI 32.2 ± 21.1/h, 95th percentile of CPAP 14.1 ± 3.8 cm H2O) were studied and NRD (electromyogram of the parasternal intercostals, EMGpara; EMG of the external oblique, EMGabdomen) was recorded (awake, supine). Awake, EMGpara declined from baseline to 70.2% ± 17.1% when CPAP of 10.7 ± 3.4 cm H2O (P = 0.026) was applied. Further increase in CPAP led to a rise in EMGpara and increased breathlessness (P = 0.02). CPAP compliance (nights used) correlated negatively with mBorg scores (r = −0.738, P = 0.006). Conclusions: Awake, the respiratory system is maximally offloaded with lower than therapeutic CPAP levels in obese patients with OSA. Levels of NRD observed at effective CPAP levels while asleep are associated with breathlessness which may limit long-term CPAP compliance. Citation: Xiao S, Bastianpillai J, Ratneswaran C, Pengo MF, Luo Y, Jolley CJ, Moxham J, Steier J. Continuous positive airway pressure and breathlessness in obese patients with obstructive

  14. Effect of Continuous Positive Airway Pressure on Stroke Rehabilitation: A Pilot Randomized Sham-Controlled Trial

    PubMed Central

    Khot, Sandeep P.; Davis, Arielle P.; Crane, Deborah A.; Tanzi, Patricia M.; Li Lue, Denise; Claflin, Edward S.; Becker, Kyra J.; Longstreth, W.T.; Watson, Nathaniel F.; Billings, Martha E.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) predicts poor functional outcome after stroke and increases the risk for recurrent stroke. Less is known about continuous positive airway pressure (CPAP) treatment on stroke recovery. Methods: In a pilot randomized, double-blind, sham-controlled trial, adult stroke rehabilitation patients were assigned to auto-titrating or sham CPAP without diagnostic testing for OSA. Change in Functional Independence Measure (FIM), a measure of disability, was assessed between rehabilitation admission and discharge. Results: Over 18 months, 40 patients were enrolled and 10 withdrew from the study: 7 from active and 3 from sham CPAP (p > 0.10). For the remaining 30 patients, median duration of CPAP use was 14 days. Average CPAP use was 3.7 h/night, with at least 4 h nightly use among 15 patients. Adherence was not influenced by treatment assignment or stroke severity. In intention-to-treat analyses (n = 40), the median change in FIM favored active CPAP over sham but did not reach statistical significance (34 versus 26, p = 0.25), except for the cognitive component (6 versus 2.5, p = 0.04). The on-treatment analyses (n = 30) yielded similar results (total FIM: 32 versus 26, p = 0.11; cognitive FIM: 6 versus 2, p = 0.06). Conclusions: A sham-controlled CPAP trial among stroke rehabilitation patients was feasible in terms of recruitment, treatment without diagnostic testing and adequate blinding—though was limited by study retention and CPAP adherence. Despite these limitations, a trend towards a benefit of CPAP on recovery was evident. Tolerance and adherence must be improved before the full benefits of CPAP on recovery can be assessed in larger trials. Citation: Khot SP, Davis AP, Crane DA, Tanzi PM, Li Lue D, Claflin ES, Becker KJ, Longstreth WT, Watson NF, Billings ME. Effect of continuous positive airway pressure on stroke rehabilitation: a pilot randomized sham-controlled trial. J Clin Sleep Med 2016;12(7):1019–1026. PMID

  15. Does personality play a role in continuous positive airway pressure compliance?

    PubMed Central

    Maschauer, Emily L.; Fairley, Donna M.

    2017-01-01

    Key points Continuous positive airway pressure (CPAP) adherence is low among individuals with obstructive sleep apnoea. Type D personality and high scores on the depression and hypochondriasis scales on the Minnesota Multiphasic Personality Inventory (MMPI) have been identified as factors contributing to non-compliance with CPAP. Further research into personality type may assist in understanding why some people adhere to CPAP, while others fail. Obstructive sleep apnoea (OSA) is a condition characterised by repetitive, intermittent partial or complete collapse/obstruction of the upper airway during sleep. Continuous positive airway pressure (CPAP) is highly efficacious in treating OSA but its effectiveness is limited due to suboptimal acceptance and adherence rates, with as many as 50% of OSA patients discontinuing CPAP treatment within the first year. Until recently, research has focused on examining mechanistic and demographic factors that could explain nonadherence (e.g. age, sex, race and education level) with limited applicability in a prospective or clinical manner. More recent research has focused on personality factors or types of patients with OSA who comply and do not comply with CPAP adherence in an attempt to enhance the accuracy of predicting treatment compliance. Type D personality has been found to be prevalent in one third of patients with OSA. The presence of Type D personality increases noncompliance and poor treatment outcomes due to negative affectivity, social inhibition, unhealthy lifestyle, and a reluctance to consult and/or follow medical advice. Conversely, individuals who are more likely to adhere to CPAP treatment tend to have a high internal locus of control and high self-efficacy, self-refer for treatment, and have active coping skills. By assessing personality and coping skills, the clinician may gain insight into the likelihood of a patient’s adherence to treatment. If the patient displays potential risk factors for CPAP

  16. Overnight Motor Skill Learning Outcomes in Obstructive Sleep Apnea: Effect of Continuous Positive Airway Pressure

    PubMed Central

    Landry, Shane; O'Driscoll, Denise M.; Hamilton, Garun S.; Conduit, Russell

    2016-01-01

    Study Objective: To determine the effectiveness of continuous positive airway pressure (CPAP) therapy in alleviating known impairments in the overnight consolidation of motor skill learning in patients with obstructive sleep apnea (OSA). Methods: Twenty-five patients with untreated moderate-severe OSA, 13 first-night CPAP users, 17 compliant CPAP users, and 14 healthy control patients were trained on a motor sequence learning task (Sequential Finger Tapping Task, SFTT) and were subsequently tested prior to and after polysomnographic recorded sleep. Measures of subjective sleepiness (Karolinska Sleepiness Scale) and sustained attention (Psychomotor Vigilance Task) were also completed before and after sleep. Results: Typical analyses of overnight improvement on the SFTT show significantly greater overnight gains in motor task speed in controls (+11.6 ± 4.7%, p = 0.007) and compliant CPAP users (+8.9 ± 4.3%, p = 0.008) compared to patients with OSA (−4.86 ± 4.5%). Additional analyses suggest that these improvements in motor performance occurred prior to the sleep episode, as all groups significantly improved (15% to 22%) over a 10-min presleep rest period. Thereafter, performance in all groups significantly deteriorated over sleep (6% to 16%) with trends toward patients with OSA showing greater losses in performance compared to control patients and compliant CPAP users. No between-group differences in subjective sleepiness and sustained attention were found presleep and postsleep. Conclusions: The current data suggest impairments in overnight motor learning in patients with OSA may be a combination of deficient stabilization of memory over a sleep episode as well as increased vulnerability to time on task fatigue effects. Compliant CPAP usage possibly offsets both of these impediments to learning outcomes by improving both sleep quality and subsequent daytime function. Citation: Landry S, O'Driscoll DM, Hamilton GS, Conduit R. Overnight motor skill learning

  17. Is the Relationship between Race and Continuous Positive Airway Pressure Adherence Mediated by Sleep Duration?

    PubMed Central

    Billings, Martha E.; Rosen, Carol L.; Wang, Rui; Auckley, Dennis; Benca, Ruth; Foldvary-Schaefer, Nancy; Iber, Conrad; Zee, Phyllis; Redline, Susan; Kapur, Vishesh K.

    2013-01-01

    Study Objectives: Black race has been associated with decreased continuous positive airway pressure (CPAP) adherence. Short sleep duration, long sleep latency, and insomnia complaints may affect CPAP adherence as they affect sleep and opportunity to use CPAP. We assessed whether self-reported sleep measures were associated with CPAP adherence and if racial variations in these sleep characteristics may explain racial differences in CPAP adherence. Design: Analysis of data from a randomized controlled trial (HomePAP), which investigated home versus laboratory-based diagnosis and treatment of obstructive sleep apnea. Setting: Seven American Academy of Sleep Medicine-accredited sleep centers in five cities in the United States. Patients or Participants: Enrolled subjects (n = 191) with apnea-hypopnea index ≥ 15 and sleepiness (Epworth Sleepiness Scale > 12). Interventions: N/A. Measurements and Results: Multivariable regression was used to assess if subjective sleep measures and symptoms predicted 3-mo CPAP use. Mediation analysis was used to assess if sleep measures mediated the association of race with CPAP adherence. Black participants reported shorter sleep duration and longer sleep latency at baseline than white and Hispanic participants. Shorter sleep duration and longer sleep latency predicted worse CPAP adherence. Sleep duration mediated the association of black race with lower CPAP adherence. However, insomnia symptoms were not associated with race or CPAP adherence. Conclusions: Among subjects with similar severity of obstructive sleep apnea and sleepiness, baseline self-reported sleep duration and latency, but not perceived insomnia, predicted CPAP adherence over 3 mo. Sleep duration explains some of the observed differences in CPAP use by race. Sleep duration and latency should be considered when evaluating poor CPAP adherence. Clinical Trial Information: Portable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http

  18. Similarity and Enhancement: Nasality from Moroccan Arabic Pharyngeals and Nasals

    ERIC Educational Resources Information Center

    Zellou, Georgia Eve

    2012-01-01

    Experimental studies of the articulation, acoustics, and perception of nasal and pharyngeal consonants and adjacent vowels were conducted to investigate nasality in Moroccan Arabic (MA). The status of nasality in MA is described as coarticulatorily complex, where two phoneme types (pharyngeal segments and nasal segments) yield similar…

  19. Comparison of Nasal Acceleration and Nasalance across Vowels

    ERIC Educational Resources Information Center

    Thorp, Elias B.; Virnik, Boris T.; Stepp, Cara E.

    2013-01-01

    Purpose: The purpose of this study was to determine the performance of normalized nasal acceleration (NNA) relative to nasalance as estimates of nasalized versus nonnasalized vowel and sentence productions. Method: Participants were 18 healthy speakers of American English. NNA was measured using a custom sensor, and nasalance was measured using…

  20. Similarity and Enhancement: Nasality from Moroccan Arabic Pharyngeals and Nasals

    ERIC Educational Resources Information Center

    Zellou, Georgia Eve

    2012-01-01

    Experimental studies of the articulation, acoustics, and perception of nasal and pharyngeal consonants and adjacent vowels were conducted to investigate nasality in Moroccan Arabic (MA). The status of nasality in MA is described as coarticulatorily complex, where two phoneme types (pharyngeal segments and nasal segments) yield similar…

  1. Comparison of Nasal Acceleration and Nasalance across Vowels

    ERIC Educational Resources Information Center

    Thorp, Elias B.; Virnik, Boris T.; Stepp, Cara E.

    2013-01-01

    Purpose: The purpose of this study was to determine the performance of normalized nasal acceleration (NNA) relative to nasalance as estimates of nasalized versus nonnasalized vowel and sentence productions. Method: Participants were 18 healthy speakers of American English. NNA was measured using a custom sensor, and nasalance was measured using…

  2. Effect of continuous positive airway pressure therapy on hypothalamic-pituitary-adrenal axis function and 24-h blood pressure profile in obese men with obstructive sleep apnea syndrome.

    PubMed

    Carneiro, Gláucia; Togeiro, Sônia Maria; Hayashi, Lílian F; Ribeiro-Filho, Fernando Flexa; Ribeiro, Artur Beltrame; Tufik, Sérgio; Zanella, Maria Teresa

    2008-08-01

    Obstructive sleep apnea syndrome (OSAS) increases the risk of cardiovascular events. Sympathetic nervous system and hypothalamic-pituitary-adrenal (HPA) axis activation may be the mechanism of this relationship. The aim of this study was to evaluate HPA axis and ambulatory blood pressure monitoring in obese men with and without OSAS and to determine whether nasal continuous positive airway pressure therapy (nCPAP) influenced responses. Twenty-four-hour ambulatory blood pressure monitoring and overnight cortisol suppression test with 0.25 mg of dexamethasone were performed in 16 obese men with OSAS and 13 obese men controls. Nine men with severe apnea were reevaluated 3 mo after nCPAP therapy. Body mass index and blood pressure of OSAS patients and obese controls were similar. In OSAS patients, the percentage of fall in systolic blood pressure at night (P = 0.027) and salivary cortisol suppression postdexamethasone (P = 0.038) were lower, whereas heart rate (P = 0.022) was higher compared with obese controls. After nCPAP therapy, patients showed a reduction in heart rate (P = 0.036) and a greater cortisol suppression after dexamethasone (P = 0.001). No difference in arterial blood pressure (P = 0.183) was observed after 3 mo of nCPAP therapy. Improvement in cortisol suppression was positively correlated with an improvement in apnea-hypopnea index during nCPAP therapy (r = 0.799, P = 0.010). In conclusion, men with OSAS present increased postdexamethasone cortisol levels and heart rate, which were recovered by nCPAP.

  3. Continuous positive airway pressure (CPAP) decreases pulmonary shunt in anaesthetized horses.

    PubMed

    Mosing, Martina; MacFarlane, Paul; Bardell, David; Lüthi, Laura; Cripps, Peter J; Bettschart-Wolfensberger, Regula

    2016-11-01

    To evaluate the effects of continuous positive airway pressure (CPAP) on intrapulmonary shunt, cardiac output and oxygen delivery in horses subjected to a 6 hour period of general anaesthesia. Randomized, experimental, crossover study. Ten healthy adult horses. Following medetomidine, diazepam and ketamine administration, orotracheal intubation was performed and horses positioned in dorsal recumbency. Anaesthesia was maintained with isoflurane carried in an oxygen and air mix (FiO2 0.5) combined with a medetomidine infusion. Horses were anaesthetized twice and either CPAP (8 cmH2 O) or physiologic airway pressure (NO CPAP) was applied to the lungs for 6 hours; the order of treatments was randomly assigned. Following induction of anaesthesia, cardiovascular and respiratory variables (including arterial blood gas analysis) were recorded every 30 minutes, cardiac output was measured every 60 minutes using the lithium dilution technique and oxygen delivery calculated. If PaCO2 exceeded 100 mmHg (13.3 kPa), controlled ventilation was initiated and horses excluded from further data collection. Groups were compared using a general linear model. Data from eight horses were analysed. PaO2 was 15-56 mmHg (2.00-7.45 kPa) higher (p < 0.001) and shunt fraction 6-14% lower (p < 0.001) in the CPAP group. No differences were seen for cardiac output and oxygen delivery. The lack of difference in oxygen delivery was attributed to lower haemoglobin levels in the CPAP group than in the NO CPAP group. CPAP of 8 cmH2 O can be used in dorsally recumbent horses to decrease pulmonary shunt fraction without causing a decrease in cardiac output during longterm anaesthesia. © 2016 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  4. Adapting the Bird Mark 7 to deliver noninvasive continuous positive airway pressure: a bench study.

    PubMed

    Kikuti, Beatriz Mayumi; Utsunomia, Karen; Colaneri, Renata Potonyacz; Carvalho, Carlos Roberto Ribeiro de; Caruso, Pedro

    2008-03-01

    To test the efficiency of the Bird Mark 7 ventilator adapted to deliver continuous positive airway pressure (CPAP) in noninvasive positive pressure ventilation. This was an experimental study using a mechanical model of the respiratory system. A Bird Mark 7 ventilator was supplied with 400 and 500 kPa and tested at CPAP of 5, 10 and 15 cmH2O. The following variables were analyzed: difference between the preset CPAP and the CPAP actually attained CPAP (trueCPAP); area of airway pressure at the CPAP level employed (AREA CPAP); and tidal volume generated. Adapting the Bird Mark 7 to offer CPAP achieved the expected tidal volume in all situations of inspiratory effort (normal or high), ventilator pressure supply (400 or 500 kPa) and CPAP value (5, 10 or 15 cmH2O). At a CPAP of 5 or 10 cmH2O, the trueCPAP was near the preset level, and the AREA CPAP was near zero. However, at a CPAP of 15 cmH2O, the value remained below the preset, and the AREA CPAP was high. The efficiency of Bird Mark 7 adaptation in offering CPAP was satisfactory at 5 and 10 cmH2O but insufficient at 15 cmH2O. If adapted as described in our study, the Bird Mark 7 might be an option for offering CPAP up to 10 cmH2O in areas where little or no equipment is available.

  5. Lung Volume and Continuous Positive Airway Pressure Requirements in Obstructive Sleep Apnea

    PubMed Central

    Heinzer, Raphael C.; Stanchina, Michael L.; Malhotra, Atul; Fogel, Robert B.; Patel, Sanjay R.; Jordan, Amy S.; Schory, Karen; White, David P.

    2005-01-01

    Previous studies have demonstrated that lung volume during wakefulness influences upper airway size and resistance, particularly in patients with sleep apnea. We sought to determine the influence of lung volume on the level of continuous positive airway pressure (CPAP) required to prevent flow limitation during non-REM sleep in subjects with sleep apnea. Seventeen subjects (apnea–hypopnea index, 42.6 ± 6.2 [SEM]) were studied during stable non-REM sleep in a rigid head-out shell equipped with a positive/negative pressure attachment for manipulation of extrathoracic pressure. An epiglottic pressure catheter plus a mask/pneumotachometer were used to assess flow limitation. When lung volume was increased by 1,035 ± 22 ml, the CPAP level could be decreased from 11.9 ± 0.7 to 4.8 ± 0.7 cm H2O (p < 0.001) without flow limitation. The decreased CPAP at the same negative extrathoracic pressure yielded a final lung volume increase of 421 ± 36 ml above the initial value. Conversely, when lung volume was reduced by 732 ± 74 ml (n = 8), the CPAP level had to be increased from 11.9 ± 0.7 to 17.1 ± 1.0 cm H2O (p < 0.001) to prevent flow limitation, with a final lung volume decrease of 567 ± 78 ml. These results demonstrate that relatively small changes in lung volume have an important effect on the upper airway in subjects with sleep apnea during non-REM sleep. PMID:15817803

  6. An Indoor Continuous Positioning Algorithm on the Move by Fusing Sensors and Wi-Fi on Smartphones.

    PubMed

    Li, Huaiyu; Chen, Xiuwan; Jing, Guifei; Wang, Yuan; Cao, Yanfeng; Li, Fei; Zhang, Xinlong; Xiao, Han

    2015-12-11

    Wi-Fi indoor positioning algorithms experience large positioning error and low stability when continuously positioning terminals that are on the move. This paper proposes a novel indoor continuous positioning algorithm that is on the move, fusing sensors and Wi-Fi on smartphones. The main innovative points include an improved Wi-Fi positioning algorithm and a novel positioning fusion algorithm named the Trust Chain Positioning Fusion (TCPF) algorithm. The improved Wi-Fi positioning algorithm was designed based on the properties of Wi-Fi signals on the move, which are found in a novel "quasi-dynamic" Wi-Fi signal experiment. The TCPF algorithm is proposed to realize the "process-level" fusion of Wi-Fi and Pedestrians Dead Reckoning (PDR) positioning, including three parts: trusted point determination, trust state and positioning fusion algorithm. An experiment is carried out for verification in a typical indoor environment, and the average positioning error on the move is 1.36 m, a decrease of 28.8% compared to an existing algorithm. The results show that the proposed algorithm can effectively reduce the influence caused by the unstable Wi-Fi signals, and improve the accuracy and stability of indoor continuous positioning on the move.

  7. An Indoor Continuous Positioning Algorithm on the Move by Fusing Sensors and Wi-Fi on Smartphones

    PubMed Central

    Li, Huaiyu; Chen, Xiuwan; Jing, Guifei; Wang, Yuan; Cao, Yanfeng; Li, Fei; Zhang, Xinlong; Xiao, Han

    2015-01-01

    Wi-Fi indoor positioning algorithms experience large positioning error and low stability when continuously positioning terminals that are on the move. This paper proposes a novel indoor continuous positioning algorithm that is on the move, fusing sensors and Wi-Fi on smartphones. The main innovative points include an improved Wi-Fi positioning algorithm and a novel positioning fusion algorithm named the Trust Chain Positioning Fusion (TCPF) algorithm. The improved Wi-Fi positioning algorithm was designed based on the properties of Wi-Fi signals on the move, which are found in a novel “quasi-dynamic” Wi-Fi signal experiment. The TCPF algorithm is proposed to realize the “process-level” fusion of Wi-Fi and Pedestrians Dead Reckoning (PDR) positioning, including three parts: trusted point determination, trust state and positioning fusion algorithm. An experiment is carried out for verification in a typical indoor environment, and the average positioning error on the move is 1.36 m, a decrease of 28.8% compared to an existing algorithm. The results show that the proposed algorithm can effectively reduce the influence caused by the unstable Wi-Fi signals, and improve the accuracy and stability of indoor continuous positioning on the move. PMID:26690447

  8. 21 CFR 874.5550 - Powered nasal irrigator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered nasal irrigator. 874.5550 Section 874.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5550 Powered nasal irrigator....

  9. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint....

  10. 21 CFR 874.5550 - Powered nasal irrigator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered nasal irrigator. 874.5550 Section 874.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5550 Powered nasal irrigator....

  11. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint....

  12. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint....

  13. 21 CFR 874.5550 - Powered nasal irrigator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered nasal irrigator. 874.5550 Section 874.5550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5550 Powered nasal irrigator....

  14. Continuous Positive Airway Pressure Device Time to Procurement in a Disadvantaged Population.

    PubMed

    DelRosso, Lourdes M; Hoque, Romy; Chesson, Andrew L

    2015-01-01

    Introduction. The management of obstructive sleep apnea (OSA) in patients who cannot afford a continuous positive airway pressure (CPAP) device is challenging. In this study we compare time to CPAP procurement in three groups of patients diagnosed with OSA: uninsured subsidized by a humanitarian grant (Group 1), uninsured unsubsidized (Group 2), and those with Medicare or Medicaid (Group 3). We evaluate follow-up and adherence in Group 1. We hypothesize that additional factors, rather than just the ability to obtain CPAP, may uniquely affect follow-up and adherence in uninsured patients. Methods. 30 patients were in Groups 1 and 2, respectively. 12 patients were in Group 3. Time of CPAP procurement from OSA diagnosis to CPAP initiation was assessed in all groups. CPAP adherence data was collected for Group 1 patients at 1, 3, 6, and 9 months. Results. There were no significant differences between groups in gender, age, body mass index, or apnea hypopnea index. The mean time to procurement in Group 1 was shorter compared to Group 2 but not significant. Compared to both Group 1 and Group 2, Group 3 patients had significantly shorter times to device procurement. Conclusion. Time to procurement of CPAP was significantly shorter in those with Medicaid/Medicare insurance compared to the uninsured.

  15. Tobacco industry litigation position on addiction: continued dependence on past views

    PubMed Central

    Henningfield, Jack E; Rose, Christine A; Zeller, Mitch

    2006-01-01

    This paper reviews the tobacco industry's litigation strategy for addressing the addiction issue through trial testimony by its experts, and opening and closing statements by its lawyers. Despite the fact that several companies now claim to accept, in varying degrees, the conclusions of the Surgeon General concerning tobacco addiction, the tobacco industry litigation strategy pertaining to addiction is essentially unchanged since that of the early 1980s when the issue emerged as crucial. The industry uses its experts and the process of cross‐examination of plaintiff's experts to imply that the addictiveness of tobacco and nicotine are more comparable to substances such as caffeine, chocolate, and even milk, than to heroin, cocaine and alcohol. Furthermore, the tobacco industry contends that the definition of addiction has now become so broadened as to include carrots and caffeine and hence that any concurrence that smoking is addictive, does not imply that cigarettes are addictive to the standards that drugs such as heroin and cocaine are addictive. Finally, the industry has continuously asserted that tobacco users assumed the risks of tobacco since they understood that quitting could be difficult when they began to use, and moreover, that the main barrier to cessation is lack of desire or motivation to quit and not physical addiction. These positions have been maintained through the 2004–2005 US Government litigation that was ongoing as the time of this writing. PMID:17130621

  16. Effects of continuous positive airway pressure on energy balance regulation: a systematic review

    PubMed Central

    Shechter, Ari

    2016-01-01

    Obesity is both a cause and a possible consequence of obstructive sleep apnoea (OSA), as OSA seems to affect parameters involved in energy balance regulation, including food intake, hormonal regulation of hunger/satiety, energy metabolism and physical activity. It is known that weight loss improves OSA, yet it remains unclear why continuous positive airway pressure (CPAP) often results in weight gain. The goal of this systematic review is to explore if and how CPAP affects the behaviour and/or metabolism involved in regulating energy balance. CPAP appears to correct for a hormonal profile characterised by abnormally high leptin and ghrelin levels in OSA, by reducing the circulating levels of each. This is expected to reduce excess food intake. However, reliable measures of food intake are lacking, and not yet sufficient to make conclusions. Although studies are limited and inconsistent, CPAP may alter energy metabolism, with reports of reductions in resting metabolic rate or sleeping metabolic rate. CPAP appears to not have an appreciable effect on altering physical activity levels. More work is needed to characterise how CPAP affects energy balance regulation. It is clear that promoting CPAP in conjunction with other weight loss approaches should be used to encourage optimal outcomes in OSA patients. PMID:27824596

  17. Controlled trial of continuous positive airway pressure given by face mask for hyaline membrane disease.

    PubMed Central

    Allen, L P; Reynolds, E R; Rivers, R P; Le Souëf, P M; Wimberley, P D

    1977-01-01

    A controlled trial of elective intervention with continuous positive airway pressure (CPAP) was performed on 24 infants with hyaline membrane disease whose arterial oxygen tension (Pao2) fell below 8kPa (60 mmHg) while they were breathing a fractional inspired oxygen concentration (F1O2) greater than 0.60. A face mask was used to apply the CPAP. The progress of the 12 infants who were treated on entry to the trial was compared with that of 12 infants who were treated later. All 12 infants in the early-intervention group and 8 infants in the late-intervention group survived. When CPAP was started, Pao2 increased and the early-treated infants breathed high concentrations of oxygen for a shorter period than the late-treated infants. The 4 infants in the early-intervention group who required mechanical ventilation needed lower mean airway pressures to achieve satisfactory gas exchange than the 7 ventilated infants in the late-intervention group. We conclude that a Pao2 less than 8 kPa while breathing an F1o2 greater than 0.60 is an adequate indication for giving CPAP in hyaline membrane disease, and that early intervention with CPAP allows infants who go on to require mechanical ventilation to be ventilated at lower pressures. PMID:326199

  18. The effect of continuous positive airway pressure on metabolic variables in patients with obstructive sleep apnoea.

    PubMed

    Schlatzer, Christian; Schwarz, Esther I; Kohler, Malcolm

    2014-02-01

    Obstructive sleep apnoea (OSA) is increasingly considered as a risk factor for metabolic disturbances, such as diabetes mellitus or dyslipidaemia. Continuous positive airway pressure (CPAP) therapy, the standard treatment for patients with OSA, may improve various metabolic variables, such as insulin sensitivity, glucose metabolism, lipids, fat distribution and adipokines. Several observational and uncontrolled clinical studies claim an improvement of these metabolic variables through the use of CPAP. However, there is only a limited number of clinical randomised controlled trials (RCTs) evaluating the effect of CPAP on metabolic variables. In this review, we summarise and discuss non-randomised studies and RCTs evaluating the effect of CPAP on metabolic variables in patients with OSA. In summary, the currently available body of evidence does not support a clinically important effect of CPAP treatment on any of the investigated metabolic variables. However, some investigators found small, but statistically significant changes in some metabolic variables, thus beneficial effects of CPAP treatment in selected patient cohorts cannot be excluded. To answer this question, more data from RCTs with well-defined study populations are warranted.

  19. Adherence to Continuous Positive Airway Pressure Treatment for Obstructive Sleep Apnea: Implications for Future Interventions

    PubMed Central

    Weaver, Terri E.; Sawyer, Amy M.

    2010-01-01

    Adherence to continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) is a critical problem with adherence rates ranging from 30–60%. Poor adherence to CPAP is widely recognized as a significant limiting factor in treating OSA, reducing the overall effectiveness of the treatment and leaving many OSA patients at heightened risk for comorbid conditions, impaired function and quality of life. The extant literature examining adherence to CPAP provides critical insight to measuring adherence outcomes, defining optimal adherence levels, and predicting CPAP adherence. This research has revealed salient factors that are associated with or predict CPAP adherence and may guide the development of interventions to promote CPAP adherence. Over the past 10 years, intervention studies to promote CPAP adherence have incorporated a multitude of strategies including education, support, cognitive behavioral approaches, and mixed strategies. This review of the current state of science of CPAP adherence will (1) synthesize the extant literature with regard to measuring, defining, and predicting CPAP adherence, (2) review published intervention studies aimed at promoting CPAP adherence, and (3) suggest directions for future empiric study of adherence to CPAP that will have implications for translational science. Our current understanding of CPAP adherence suggests that adherence is a multi-factorial, complex clinical problem that requires similarly designed approaches to effectively address poor CPAP adherence in the OSA population. PMID:20308750

  20. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    PubMed Central

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to methacholine was assessed using the in vitro living lung slice preparation. Results One week of CPAP increased AW responsiveness to methacholine in male, but not female mice, compared to untreated control animals. The AW hyper-reactivity of male mice persisted for 2 weeks (at P21) after CPAP treatment ended. 4 days of CPAP, however, did not significantly increase AW reactivity. Females also exhibited AW hyper-reactivity at P21, suggesting a delayed response to early (7 days) CPAP treatment. The effects of 7 days of CPAP on hyper-reactivity to methacholine were unique to smaller AWs whereas larger ones were relatively unaffected. Conclusion These data may be important to our understanding of the potential long-term consequences of neonatal CPAP therapy used in the intensive care of preterm infants. PMID:25950451

  1. Continuous positive pressure ventilation during epidural blockade--effects on cardiac output distribution.

    PubMed

    Elowsson, P; Norlén, K; Jakobson, S

    2001-01-01

    It has been shown that when cardiac output (CO) decreases during continuous positive pressure ventilation (CPPV), its regional distribution adapts with a favouring of vital organs. Does epidural blockade modify this adaptation? Regional blood flows were assessed by the microsphere technique (15 microm) in 17 anaesthetised pigs during spontaneous breathing and CPPV with 8 cm H2O end-expiratory pressure (CPPV8) before and after epidural blockade. The block was induced at either the Th6-7 (Thep) or the L6-S1 (Lep) level with 1 ml of lidocaine 40 mg x ml(-1). When Lep was combined with CPPV8, mean arterial pressure and CO decreased significantly, and they decreased even more when combined with Thep. In contrast, the relative perfusion of the central nervous system, heart and kidneys remained stable during the four conditions studied. The adrenal perfusion during CPPV8 was obviated by epidural blockade. The absolute and relative perfusion of the skeletal muscle decreased during epidural blockade. The administered doses of epidural lidocaine did not affect blood flow in the spinal cord. The locally mediated nutritive vasoregulation of vital organs outweighed the sympathetic blockade induced by epidural blockade. During Thep blockade the animals were less capable of responding to the haemodynamic changes induced by CPPV8, probably due to the blockade of the cardiac part of the sympathetic nervous system.

  2. Tobacco industry litigation position on addiction: continued dependence on past views.

    PubMed

    Henningfield, Jack E; Rose, Christine A; Zeller, Mitch

    2006-12-01

    This paper reviews the tobacco industry's litigation strategy for addressing the addiction issue through trial testimony by its experts, and opening and closing statements by its lawyers. Despite the fact that several companies now claim to accept, in varying degrees, the conclusions of the Surgeon General concerning tobacco addiction, the tobacco industry litigation strategy pertaining to addiction is essentially unchanged since that of the early 1980s when the issue emerged as crucial. The industry uses its experts and the process of cross-examination of plaintiff's experts to imply that the addictiveness of tobacco and nicotine are more comparable to substances such as caffeine, chocolate, and even milk, than to heroin, cocaine and alcohol. Furthermore, the tobacco industry contends that the definition of addiction has now become so broadened as to include carrots and caffeine and hence that any concurrence that smoking is addictive, does not imply that cigarettes are addictive to the standards that drugs such as heroin and cocaine are addictive. Finally, the industry has continuously asserted that tobacco users assumed the risks of tobacco since they understood that quitting could be difficult when they began to use, and moreover, that the main barrier to cessation is lack of desire or motivation to quit and not physical addiction. These positions have been maintained through the 2004-2005 US Government litigation that was ongoing as the time of this writing.

  3. Critical care patients' experience of the helmet continuous positive airway pressure.

    PubMed

    Dimech, Andrew

    2012-01-01

    Continuous positive airway pressure (CPAP) is a common treatment modality for acute respiratory failure (ARF) in critical care. Historically, a tight-fitting mask is used to provide respiratory support. This however is not without risks to the patient. The helmet CPAP is a new product that provides the same treatment with a different method of delivery. There is minimal evidence to date explaining the patient's experience of the new helmet modality. The aim of this research study is to explore critical care patient's experience of helmet CPAP. A qualitative approach was taken utilizing descriptive phenomenological methodology. In order to obtain rich data, six interviews with cues provided the platform for data generation and collection. A thematic framework was utilized with emergent themes manually analysed using a constant comparative technique to express the experiences or phenomena of a particular event or experiences. The overall experience was unique to each patient. The patients entrusted the health care team which made the experience more tolerable. Paradoxical themes were experienced during treatment. The themes included entrapment, confusion, helping me breathe, liberation, challenges, apprehension, relief, trust and endurance. The desire to survive the acute illness proved to be a driving factor. The study has provided an insight into the patient's experience of helmet CPAP in the critical care setting. The findings have provided a basis for policy and guideline development. It will also assist in developing future patient focused care. © 2012 The Author. Nursing in Critical Care © 2012 British Association of Critical Care Nurses.

  4. Continuous Positive Airway Pressure Device Time to Procurement in a Disadvantaged Population

    PubMed Central

    DelRosso, Lourdes M.; Chesson, Andrew L.

    2015-01-01

    Introduction. The management of obstructive sleep apnea (OSA) in patients who cannot afford a continuous positive airway pressure (CPAP) device is challenging. In this study we compare time to CPAP procurement in three groups of patients diagnosed with OSA: uninsured subsidized by a humanitarian grant (Group 1), uninsured unsubsidized (Group 2), and those with Medicare or Medicaid (Group 3). We evaluate follow-up and adherence in Group 1. We hypothesize that additional factors, rather than just the ability to obtain CPAP, may uniquely affect follow-up and adherence in uninsured patients. Methods. 30 patients were in Groups 1 and 2, respectively. 12 patients were in Group 3. Time of CPAP procurement from OSA diagnosis to CPAP initiation was assessed in all groups. CPAP adherence data was collected for Group 1 patients at 1, 3, 6, and 9 months. Results. There were no significant differences between groups in gender, age, body mass index, or apnea hypopnea index. The mean time to procurement in Group 1 was shorter compared to Group 2 but not significant. Compared to both Group 1 and Group 2, Group 3 patients had significantly shorter times to device procurement. Conclusion. Time to procurement of CPAP was significantly shorter in those with Medicaid/Medicare insurance compared to the uninsured. PMID:26137322

  5. Relationships between Obstructive Sleep Apnea Syndrome, Continuous Positive Airway Pressure Treatment, and Inflammatory Cytokines

    PubMed Central

    Ünüvar Doğan, Filiz; Yosunkaya, Şebnem; Kuzu Okur, Hacer; Can, Ümmügülsüm

    2014-01-01

    The cardiovascular complications that frequently accompany obstructive sleep apnea syndrome (OSAS) are thought to develop as a result of inflammatory stress associated with cytokines such as IL-6 and TNF-α. We conducted the current study to compare levels of these cytokines in OSAS patients (n = 33) and nonapneic controls (n = 24). Furthermore, we investigated the impact of a three-month regime of continuous positive airway pressure (CPAP) on serum levels of IL-6 and TNF-α only in the OSAS patients. There were no significant differences in serum levels of either IL-6 (P = 0.782) or TNF- α (P = 0.722) or TNF-α (P = 0.722) between OSAS patients and nonapneic controls. Serum IL-6 levels correlated significantly with neck circumference in OSAS patients (P = 0.006). In OSAS patients, reduced levels of TNF-α and IL-6 correlated with increases in mean SaO2 after CPAP treatment (P = 0.020 and P = 0.051, resp.). However, neither of cytokine levels was significantly impacted by CPAP therapy (both P > 0.137). We have demonstrated that plasma cytokine levels are similar in both otherwise healthy subjects with OSAS and in nonapneic control, and we conclude that OSAS-related parameters and CPAP treatment do not play a significant role in altering cytokine levels. PMID:24895539

  6. Alternative methods of titrating continuous positive airway pressure: a large multicenter study.

    PubMed

    Masa, Juan F; Jiménez, Antonio; Durán, Joaquín; Capote, Francisco; Monasterio, Carmen; Mayos, Mercedes; Terán, Joaquín; Hernández, Lourdes; Barbé, Ferrán; Maimó, Andrés; Rubio, Manuela; Montserrat, José M

    2004-12-01

    Standard practice for continuous positive airway pressure (CPAP) treatment in sleep apnea and hypopnea syndrome (SAHS) requires pressure titration during attended laboratory polysomnography. However, polysomnographic titration is expensive and time-consuming. The aim of this study was to ascertain, in a large sample of CPAP-naive patients, whether CPAP titration performed by an unattended domiciliary autoadjusted CPAP device or with a predicted formula was as effective as CPAP titration performed by full polysomnography. The main outcomes were the apnea-hypopnea index and the subjective daytime sleepiness. We included 360 patients with SAHS requiring CPAP treatment. Patients were randomly allocated into three groups: standard, autoadjusted, and predicted formula titration with domiciliary adjustment. The follow-up period was 12 weeks. With CPAP treatment, the improvement in subjective sleepiness and apnea-hypopnea index was very similar in the three groups. There were no differences in the objective compliance of CPAP treatment and in the dropout rate of the three groups at the end of the follow-up. Autoadjusted titration at home and predicted formula titration with domiciliary adjustment can replace standard titration. These procedures could lead to considerable savings in cost and to significant reductions in the waiting list.

  7. Patient experience with mupirocin or povidone-iodine nasal decolonization.

    PubMed

    Maslow, Jed; Hutzler, Lorraine; Cuff, Germaine; Rosenberg, Andrew; Phillips, Michael; Bosco, Joseph

    2014-06-01

    Led by the federal government, the payers of health care are enacting policies designed to base provider reimbursement on the quality of care they render. This study evaluated and compared patient experiences and satisfaction with nasal decolonization with either nasal povidone-iodine (PI) or nasal mupirocin ointment (MO). A total of 1903 patients were randomized to undergo preoperative nasal decolonization with either nasal MO or PI solution. All randomized patients were also given 2% chlorhexidine gluconate topical wipes. Patients were interviewed prior to discharge to assess adverse events and patient experience with their assigned preoperative antiseptic protocol. Of the 1903 randomized patients, 1679 (88.1%) were interviewed prior to discharge. Of patients receiving PI, 3.4% reported an unpleasant or very unpleasant experience, compared with 38.8% of those using nasal MO (P<.0001). Sixty-seven percent of patients using nasal MO believed it to be somewhat or very helpful in reducing surgical site infections, compared with 71% of patients receiving PI (P>.05). Being recruited as an active participant in surgical site infection prevention was a positive experience for 87.2% of MO patients and 86.3% of PI patients (P=.652). Those assigned to receive PI solution preoperatively reported significantly fewer adverse events than the nasal MO group (P<.01). Preoperative nasal decolonization with either nasal PI or MO was considered somewhat or very helpful by more than two-thirds of patients. Copyright 2014, SLACK Incorporated.

  8. [Successful treatment of laryngomalacia and bilateral vocal cord paralysis with continuous positive airway pressure].

    PubMed

    Sovtić, Aleksandar; Minić, Predrag; Vukcević, Miodrag; Rodić, Milan

    2010-01-01

    Laryngomalacia is the most frequent congenital anomaly of airways, and it may cause obstructive sleep apneas. The associated vocal cord paralysis may aggravate the symptoms of upper airway obstruction. In a 14 month old boy severe laryngomalacia and bilateral vocal cord paralysis were diagnosed by flexible bronchoscopy. A sleep study showed a severe obstructive sleep apnoea (OSA). The patient was ventilated at home via the face mask with non invasive mechanical ventilation (CPAP) for a year. The level of pressure had to be set at 7 cm H2O to correct desaturation with an improvement in mean SpO2. On the follow up bronchoscopic examination laryngomalatia was improved, vocal cord paralysis persisted and sleep study revealed significant improvement. In the patient with severe laryngomalatia and bilateral vocal cord paralysis with OSA conservative treatment with CPAP was used instead of a surgical intervention. Non invasive ventilation was used every night, for at least 6 hours, without adverse events. Invasive measurement of transdiaphragmatic pressure is the best way of titrating of CPAP level. This case report suggests the efficacy of noninvasive titrating of CPAP level by the hemoglobin oxygen saturation trend measurement. In case of severe laryngomalatia and associated vocal cord paralysis, followed by OSA non invasive ventilation by nasal CPAP represents an effective and safe alternative to surgery.

  9. Continuous positive airway pressure for bronchiolitis in a general paediatric ward; a feasibility study.

    PubMed

    Oymar, Knut; Bårdsen, Kjersti

    2014-05-12

    Continuous positive airway pressure (CPAP) is commonly used to relieve respiratory distress in infants with bronchiolitis, but has mostly been studied in an intensive care setting. Our prime aim was to evaluate the feasibility of CPAP for infants with bronchiolitis in a general paediatric ward, and secondary to assess capillary PCO2 (cPCO2) levels before and during treatment. From May 1(st) 2008 to April 30(th) 2012, infants with bronchiolitis at Stavanger University Hospital were treated with CPAP in a general paediatric ward, but could be referred to an intensive care unit (ICU) when needed, according to in-house guidelines. Levels of cPCO2 were prospectively registered before the start of CPAP and at approximately 4, 12, 24 and 48 hours of treatment as long as CPAP was given. We had a continuous updating program for the nurses and physicians caring for the infants with CPAP. The study was population based. 672 infants (3.4%) were hospitalized with bronchiolitis. CPAP was initiated in 53 infants (0.3%; 7.9% of infants with bronchiolitis), and was well tolerated in all but three infants. 46 infants were included in the study, the majority of these (n = 33) were treated in the general ward only. These infants had lower cPCO2 before treatment (8.0; 7.7, 8.6)(median; quartiles) than those treated at the ICU (n = 13) (9.3;8.5, 9.9) (p < 0.001). The level of cPCO2 was significantly reduced after 4 h in both groups; 1.1 kPa (paediatric ward) (p < 0.001) and 1.3 kPa (ICU) (p = 0.002). Two infants on the ICU did not respond to CPAP (increasing cPCO2 and severe apnoe) and were given mechanical ventilation, otherwise no side effects were observed in either group treated with CPAP. Treatment with CPAP for infants with bronchiolitis may be feasible in a general paediatric ward, providing sufficient staffing and training, and the possibility of referral to an ICU when needed.

  10. Continuous positive airway pressure for bronchiolitis in a general paediatric ward; a feasibility study

    PubMed Central

    2014-01-01

    Background Continuous positive airway pressure (CPAP) is commonly used to relieve respiratory distress in infants with bronchiolitis, but has mostly been studied in an intensive care setting. Our prime aim was to evaluate the feasibility of CPAP for infants with bronchiolitis in a general paediatric ward, and secondary to assess capillary PCO2 (cPCO2) levels before and during treatment. Methods From May 1st 2008 to April 30th 2012, infants with bronchiolitis at Stavanger University Hospital were treated with CPAP in a general paediatric ward, but could be referred to an intensive care unit (ICU) when needed, according to in-house guidelines. Levels of cPCO2 were prospectively registered before the start of CPAP and at approximately 4, 12, 24 and 48 hours of treatment as long as CPAP was given. We had a continuous updating program for the nurses and physicians caring for the infants with CPAP. The study was population based. Results 672 infants (3.4%) were hospitalized with bronchiolitis. CPAP was initiated in 53 infants (0.3%; 7.9% of infants with bronchiolitis), and was well tolerated in all but three infants. 46 infants were included in the study, the majority of these (n = 33) were treated in the general ward only. These infants had lower cPCO2 before treatment (8.0; 7.7, 8.6)(median; quartiles) than those treated at the ICU (n = 13) (9.3;8.5, 9.9) (p < 0.001). The level of cPCO2 was significantly reduced after 4 h in both groups; 1.1 kPa (paediatric ward) (p < 0.001) and 1.3 kPa (ICU) (p = 0.002). Two infants on the ICU did not respond to CPAP (increasing cPCO2 and severe apnoe) and were given mechanical ventilation, otherwise no side effects were observed in either group treated with CPAP. Conclusion Treatment with CPAP for infants with bronchiolitis may be feasible in a general paediatric ward, providing sufficient staffing and training, and the possibility of referral to an ICU when needed. PMID:24886569

  11. [Survey of sensory perception and patients' subjective assessment of the application of nasal sprays - the nasal-spray-sensoric-scale].

    PubMed

    Mösges, Ralph; Pasch, N; Sayar, A; Schmalz, P; Vent, J

    2009-09-01

    The Nasal Spray Evaluation Questionnaire is a standardized means to evaluate hedonicity of nasal sprays in the English speaking countries. To date, there is no such questionnaire for German speaking patients. The here presented study aimed at evaluating the translated questionnaire. Three nasal sprays were tested and the questionnaire was used to estimate sensory hedonicity. Finally, the questionnaire was improved and can now serve as a standardized means to measure nasal sensory perceptions. The questionnaire was literally translated from English to German. There were three groups of 60 patients each presenting with the sensation of a 'dry nose' to a secondary medical center with a board certified otolaryngologist. The ingredients of the three different nasal sprays varied only in one phytotherapeutic addition. The first evaluation of the nasal spray was conducted immediately after application of the nasal spray, and two minutes after application. A third and optional telephone survey was performed several days later after continuous use of the spray. The different evaluations of nasal sprays were already lined out after the first questionnaire. It could serve as a new, reliable and reproduceable tool for the evaluation of nasal sensory perceptions. The questionnaire served as an adequate tool to estimate hedonicity of nasal sprays. First results of the German version show, however, that it could facilitate the evaluation by restructuring the questionnaire. Continuously marking good grades with high points (maximum 100) and negative answers with low points (minimum 0 points) will unify and simplify the questionnaire. The translation of the Nasal Spray Evaluation Questionnaire into a German version can serve as a new standard tool for measuring nasal sensation. Georg Thieme Verlag KG Stuttgart * New York.

  12. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    PubMed

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P < 0.001). After using a ΔP of 3 cmH(2)O for the cutoff value (ΔP was defined as the difference of automatic titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P < 0.001). However, there were no differences for the pressure of manual titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the

  13. Development of the cetacean nasal skull.

    PubMed

    Klima, M

    1999-01-01

    The adaptation of cetaceans to aquatic life habits is reflected, in their nasal region, in three marked changes from the original relations found in land mammals. These changes include (1) the loss of the sense of smell, (2) translocation of the nostrils from the tip of the rostrum to the vertex of the head, and (3) elongation of the anterior head to form a rostrum protruding far towards anterior. The morphogenetic processes taking place during embryogenesis of the nasal skull play a decisive part in the development of all these changes. The lateral parts of the embryonic nasal capsule, encompassing the nasal passages, change their position from horizontal to vertical. At the same time, the structures of the original nasal floor (the solum nasi) are shifted in front of the nasal passages towards the rostrum. The structures of the original nasal roof (the tectum nasi) and of the nasal side wall (the paries nasi) are translocated behind the nasal passages towards the neurocranium. The medial nasal septum (the septum nasi) mostly loses its connection to the nasal passages and is produced into a point protruding far towards anterior. The transformed embryonic nasal skull of the Cetacea can be divided into three sections: 1. The median structures. These include the cartilaginous structures, viz., the rostrum nasi, the septum interorbitale and the spina mesethmoidalis, which are accompanied by the dermal bones, the vomer and the praemaxillare. In adult cetaceans the rostrum nasi is mostly preserved as a robust cartilage of the skull, which may possibly serve as a sound transmitting structure of the sonar system, or it may be responsible for the sensing of water streams and vibrations. 2. The posterior side wall structures. These include the following cartilaginous structures that are mostly heavily reduced or mutually fused: the cupula nasi anterior, the tectum nasi, the lamina cribrosa, the paries nasi, the commissura orbitonasalis, the cupula nasi posterior, the

  14. Nasal septal trauma in children.

    PubMed

    Olsen, K D; Carpenter, R J; Kern, E B

    1979-07-01

    If the septal component of a nasal injury is adequately managed, usually the entire nasal injury will be well managed. Major or minor nasal trauma can cause cartilage fracture, deviation, dislocation, hematoma, or abscess formation, and the various associated sequelae, some of them life-threatening. A negative x-ray report should never be used as a substitute for a complete intranasal examination in any child with nasal trauma. Any nasal abnormality should be referred for immediate evaluation and treatment.

  15. Application of continuous positive airway pressure in the delivery room: a multicenter randomized clinical trial

    PubMed Central

    Gonçalves-Ferri, W.A.; Martinez, F.E.; Caldas, J.P.S.; Marba, S.T.M.; Fekete, S.; Rugolo, L.; Tanuri, C.; Leone, C.; Sancho, G.A.; Almeida, M.F.B.; Guinsburg, R.

    2014-01-01

    This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min. PMID:24554040

  16. Application of continuous positive airway pressure in the delivery room: a multicenter randomized clinical trial.

    PubMed

    Gonçalves-Ferri, W A; Martinez, F E; Caldas, J P S; Marba, S T M; Fekete, S; Rugolo, L; Tanuri, C; Leone, C; Sancho, G A; Almeida, M F B; Guinsburg, R

    2014-02-01

    This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min.

  17. Randomized trial of early bubble continuous positive airway pressure for very low birth weight infants.

    PubMed

    Tapia, Jose L; Urzua, Soledad; Bancalari, Aldo; Meritano, Javier; Torres, Gabriela; Fabres, Jorge; Toro, Claudia A; Rivera, Fabiola; Cespedes, Elizabeth; Burgos, Jaime F; Mariani, Gonzalo; Roldan, Liliana; Silvera, Fernando; Gonzalez, Agustina; Dominguez, Angelica

    2012-07-01

    To determine whether very low birth weight infants (VLBWIs), initially supported with continuous positive airway pressure (CPAP) and then selectively treated with the INSURE (intubation, surfactant, and extubation to CPAP; CPAP/INSURE) protocol, need less mechanical ventilation than those supported with supplemental oxygen, surfactant, and mechanical ventilation if required (Oxygen/mechanical ventilation [MV]). In a multicenter randomized controlled trial, spontaneously breathing VLBWIs weighing 800-1500 g were allocated to receive either therapy. In the CPAP/INSURE group, if respiratory distress syndrome (RDS) did not occur, CPAP was discontinued after 3-6 hours. If RDS developed and the fraction of inspired oxygen (FiO(2)) was >0.35, the INSURE protocol was indicated. Failure criteria included FiO(2) >0.60, severe apnea or respiratory acidosis, and receipt of more than 2 doses of surfactant. In the Oxygen/MV group, in the presence of RDS, supplemental oxygen without CPAP was given, and if FiO(2) was >0.35, surfactant and mechanical ventilation were provided. A total of 256 patients were randomized to either the CPAP/INSURE group (n = 131) or the Oxygen/MV group (n = 125). The need for mechanical ventilation was lower in the CPAP/INSURE group (29.8% vs 50.4%; P = .001), as was the use of surfactant (27.5% vs 46.4%; P = .002). There were no differences in death, pneumothorax, bronchopulmonary dysplasia, and other complications of prematurity between the 2 groups. CPAP and early selective INSURE reduced the need for mechanical ventilation and surfactant in VLBWIs without increasing morbidity and death. These results may be particularly relevant for resource-limited regions. Copyright © 2012 Mosby, Inc. All rights reserved.

  18. Effectiveness of prehospital continuous positive airway pressure in the management of acute pulmonary edema.

    PubMed

    Hubble, Michael W; Richards, Michael E; Jarvis, Roger; Millikan, Tori; Young, Dwayne

    2006-01-01

    To compare the effectiveness of continuous positive airway pressure (CPAP) with standard pharmacologic treatment in the management of prehospital acute pulmonary edema. Using a nonrandomized control group design, all consecutive patients presenting to two participating emergency medical services (EMS) systems with a field impression of acute pulmonary edema between July 1, 2004, and June 30, 2005, were included in the study. The control EMS system patients received standard treatment with oxygen, nitrates, furosemide, morphine, and, if indicated, endotracheal intubation. The intervention EMS system patients received CPAP via face mask at 10 cm H2O in addition to standard therapy. Ninety-five patients received standard therapy, and 120 patients received CPAP and standard therapy. Intubation was required in 8.9% of CPAP-treated patients compared with 25.3% in the control group (p = 0.003), and mortality was lower in the CPAP group than in the control group (5.4% vs. 23.2%; p = 0.000). When compared with the control group, the CPAP group had more improvement in respiratory rate (-4.55 vs. -1.81; p = 0.001), pulse rate (-4.77 vs. 0.82; p = 0.013), and dyspnea score (-2.11 vs. -1.36; p = 0.008). Using logistic regression to control for potential confounders, patients receiving standard treatment were more likely to be intubated (odds ratio, 4.04; 95% confidence interval, 1.64 to 9.95) and more likely to die (odds ratio, 7.48; 95% confidence interval, 1.96 to 28.54) than those receiving standard therapy and CPAP. The prehospital use of CPAP is feasible, may avert the need for endotracheal intubation, and may reduce short-term mortality.

  19. Is the relationship between race and continuous positive airway pressure adherence mediated by sleep duration?

    PubMed

    Billings, Martha E; Rosen, Carol L; Wang, Rui; Auckley, Dennis; Benca, Ruth; Foldvary-Schaefer, Nancy; Iber, Conrad; Zee, Phyllis; Redline, Susan; Kapur, Vishesh K

    2013-02-01

    Black race has been associated with decreased continuous positive airway pressure (CPAP) adherence. Short sleep duration, long sleep latency, and insomnia complaints may affect CPAP adherence as they affect sleep and opportunity to use CPAP. We assessed whether self-reported sleep measures were associated with CPAP adherence and if racial variations in these sleep characteristics may explain racial differences in CPAP adherence. Analysis of data from a randomized controlled trial (HomePAP), which investigated home versus laboratory-based diagnosis and treatment of obstructive sleep apnea. Seven American Academy of Sleep Medicine-accredited sleep centers in five cities in the United States. Enrolled subjects (n = 191) with apnea-hypopnea index ≥ 15 and sleepiness (Epworth Sleepiness Scale > 12). N/A. Multivariable regression was used to assess if subjective sleep measures and symptoms predicted 3-mo CPAP use. Mediation analysis was used to assess if sleep measures mediated the association of race with CPAP adherence. Black participants reported shorter sleep duration and longer sleep latency at baseline than white and Hispanic participants. Shorter sleep duration and longer sleep latency predicted worse CPAP adherence. Sleep duration mediated the association of black race with lower CPAP adherence. However, insomnia symptoms were not associated with race or CPAP adherence. Among subjects with similar severity of obstructive sleep apnea and sleepiness, baseline self-reported sleep duration and latency, but not perceived insomnia, predicted CPAP adherence over 3 mo. Sleep duration explains some of the observed differences in CPAP use by race. Sleep duration and latency should be considered when evaluating poor CPAP adherence. PORTABLE MONITORING FOR DIAGNOSIS AND MANAGEMENT OF SLEEP APNEA (HOMEPAP) URL: http://clinicaltrials.gov/show/NCT00642486. NIH clinical trials registry number: NCT00642486.

  20. Obstructive sleep apnoea in the elderly: role of continuous positive airway pressure treatment.

    PubMed

    Martínez-García, Miguel Ángel; Chiner, Eusebi; Hernández, Luis; Cortes, Jose Pascual; Catalán, Pablo; Ponce, Silvia; Diaz, Jose Ramón; Pastor, Ester; Vigil, Laura; Carmona, Carmen; Montserrat, Josep Maria; Aizpuru, Felipe; Lloberes, Patricia; Mayos, Mercedes; Selma, Maria José; Cifuentes, Jose Fernando; Muñoz, Alvaro

    2015-07-01

    Almost all the information about the effect of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnoea (OSA) comes from clinical trials involving only middle-aged patients. The objective of this study was to assess the effect of CPAP treatment in elderly patients with severe OSA on clinical, quality-of-life and neurocognitive spheres. We performed an open-label, randomised, multicentre clinical trial in a consecutive clinical cohort of 224 elderly (≥70 years old) patients with confirmed severe OSA (apnoea-hypopnea index ≥30) randomised to receive CPAP (n=115) or no CPAP (n=109) for 3 months. A sleep study was performed by either full polysomnography or respiratory polygraphy. CPAP titration was performed by an autoCPAP device. The primary endpoint was quality of life (Quebec Sleep Questionnaire) and secondary endpoints included sleep-related symptoms, presence of anxiety/depression, office-based blood pressure and some neurocognitive tests. The mean±sd age was 75.5±3.9 years. The CPAP group achieved a greater improvement in all quality-of-life domains (p<0.001; effect size: 0.41-0.98), sleep-related symptoms (p<0.001; effect size 0.31-0.91) as well as anxiety (p=0.016; effect size 0.51) and depression (p<0.001; effect size: 0.28) indexes and some neurocognitive tests (digit symbol test (p=0.047; effect size: 0.20) and Trail Making Test A (p=0.029; effect size: 0.44)) in an intention-to-treat analysis. In conclusion, CPAP treatment resulted in an improvement in quality of life, sleep-related symptoms, anxiety and depression indexes and some neurocognitive aspects in elderly people with severe OSA. Copyright ©ERS 2015.

  1. Effects of Continuous Positive Airway Pressure on Middle Ear Pressure and Acoustic Stapedial Reflex.

    PubMed

    Li, Jinrang; Li, Keliang

    2016-08-01

    This study investigated the effects of continuous positive airway pressure (CPAP) on middle ear pressure and acoustic stapedial reflex and the correlation between CPAP and middle ear pressure. Prospective cohort study. Tertiary hospitals. Fifty patients with obstructive sleep apnea-hypopnea syndrome were assigned to the study group, and 50 healthy volunteers were assigned to the control group. The subjects underwent standard tympanometry while wearing a CPAP device (ie, simulated CPAP treatment), which was set to 0, 5, 10, and 15 cm H2O, respectively. Tympanometry was performed before and after swallowing at each pressure of CPAP treatment. The mean middle ear pressures were 21.2, 22.6, 22.7, and 23.4 daPa (before swallowing) and 21.6, 42.6, 81.4, and 118.6 daPa (after swallowing) in the study group and 17.6, 18.7, 19.5, and 20.8 daPa (before swallowing) and 17.7, 44.2, 85.6, and 120.5 daPa (after swallowing) in the control group at the CPAPs of 0, 5, 10, and 15 cm H2O, respectively. While the CPAPs were at 0 and 15 cm H2O, the stapedial muscle reflex at 1.0 kHz did not have a significant difference between the 2 groups (χ(2) = 0.521, P = .470). The Pearson correlation coefficient of the CPAP pressure and the middle ear pressure after swallowing was 0.812 (P < .001). CPAP affected middle ear pressure and was directly proportional to the pressure of the CPAP. However, CPAP treatment had no significant effect on stapedial muscle reflex. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  2. Biomarkers of oxidative stress following continuous positive airway pressure withdrawal: data from two randomised trials.

    PubMed

    Stradling, John R; Schwarz, Esther I; Schlatzer, Christian; Manuel, Ari R; Lee, Regent; Antoniades, Charalambos; Kohler, Malcolm

    2015-10-01

    There is conflicting evidence whether intermittent hypoxia in obstructive sleep apnoea (OSA) influences oxidative stress. We hypothesised that withdrawal of continuous positive airway pressure (CPAP) from patients with OSA would raise markers of oxidative stress.59 patients with CPAP-treated moderate-to-severe OSA (oxygen desaturation index (ODI) >20 events·h(-1)) were randomised 1:1 to either stay on CPAP (n=30) or change to sham CPAP (n=29) for 2 weeks. Using samples from two similar studies at two sites, we measured early morning blood malondialdehyde (MDA, a primary outcome in one study and a secondary outcome in the other), lipid hydroperoxides, total antioxidant capacity, superoxide generation from mononuclear cells and urinary F2-isoprostane. We also measured superoxide dismutase as a marker of hypoxic preconditioning. "Treatment" effects (sham CPAP versus CPAP) were calculated via linear regression.Sham CPAP provoked moderate-to-severe OSA (mean ODI 46 events·h(-1)), but blood markers of oxidative stress did not change significantly (MDA "treatment" effect (95% CI) -0.02 (-0.23 to +0.19) μmol·L(-1)). Urinary F2-isoprostane fell significantly by ~30% (-0.26 (-0.42 to -0.10) ng·mL(-1)) and superoxide dismutase increased similarly (+0.17 (+0.02 to +0.30) ng·mL(-1)).We found no direct evidence of increased oxidative stress in patients experiencing a return of their moderate-to-severe OSA. The fall in urinary F2-isoprostane and rise in superoxide dismutase implies that hypoxic preconditioning may have reduced oxidative stress. Copyright ©ERS 2015.

  3. Randomised controlled crossover trial of humidified continuous positive airway pressure in mild obstructive sleep apnoea

    PubMed Central

    Marshall, N; Neill, A; Campbell, A; Sheppard, D

    2005-01-01

    Background: It is unclear whether continuous positive airway pressure (CPAP), the treatment of choice for severe obstructive sleep apnoea (OSA), is effective at improving outcomes in mild OSA. Methods: To help define the role of humidified CPAP in mild OSA, a randomised crossover study was undertaken of patients with an apnoea hypopnoea index (AHI) of 5–30/hour. Subjective sleepiness, objective wakefulness, mood, reaction time, and quality of life were measured at baseline, after 3 weeks treatment with humidified CPAP and 3 weeks sham CPAP (2 week washout). Results: Twenty nine of 31 enrolled patients (age 25–67 years, seven women, mean (SD) body mass index 31.5 (6) kg/m2) completed the protocol. Humidified CPAP improved polysomnographic indices of OSA and Epworth Sleepiness Scale (2.4 points (95% CI 0.6 to 4.2)). Objective wakefulness (modified maintenance of wakefulness test) showed a trend towards improvement (5.2 minutes (95% CI –0.6 to 11)). Mood (Hospital Anxiety and Depression Scale), quality of life (SF 36, Functional Outcomes of Sleep Questionnaire), and reaction times (Psychomotor Vigilance Task) were not improved more than sham CPAP. Compliance with humidified and sham CPAP both averaged 4.9 hours/night. Placebo effects were evident in many outcomes and there was no clear treatment preference. Conclusions: Humidified CPAP improves subjective sleepiness and possibly objective wakefulness but not reaction times, quality of life, or mood. These results do not support the routine use of CPAP in all patients with mild OSA, but offers some support for the trialling of CPAP in those with severe sleepiness. PMID:15860720

  4. Noninvasive continuous positive airway pressure in acute respiratory failure: helmet versus facial mask.

    PubMed

    Chidini, Giovanna; Calderini, Edoardo; Cesana, Bruno Mario; Gandini, Cristiano; Prandi, Edi; Pelosi, Paolo

    2010-08-01

    Noninvasive continuous positive airway pressure (nCPAP) is applied through different interfaces to treat mild acute respiratory failure (ARF) in infants. Recently a new pediatric helmet was introduced in clinical practice to deliver nCPAP. The objective of this study was to compare the feasibility of the delivery of nCPAP by the pediatric helmet with delivery by a conventional facial mask in infants with ARF. We conducted a single-center physiologic, randomized, controlled study with a crossover design on 20 consecutive infants with ARF. All patients received nCPAP by helmet and facial mask in random order for 90 minutes. In infants in both trials, nCPAP treatment was preceded by periods of unassisted spontaneous breathing through a Venturi mask. The primary end point was the feasibility of nCPAP administered with the 2 interfaces (helmet and facial mask). Feasibility was evaluated by the number of trial failures defined as the occurrence of 1 of the following: intolerance to the interface; persistent air leak; gas-exchange derangement; or major adverse events. nCPAP application time, number of patients who required sedation, and the type of complications with each interface were also recorded. The secondary end point was gas-exchange improvement. Feasibility of nCPAP delivery was enhanced by the helmet compared with the mask, as indicated by a lower number of trial failures (P < .001), less patient intolerance (P < .001), longer application time (P < .001), and reduced need for patient sedation (P < .001). For both delivery methods, no major patient complications occurred. The results of this current study revealed that the helmet is a feasible alternative to the facial mask for delivery of nCPAP to infants with mild ARF.

  5. Association between continuous positive airway pressure and circulating omentin levels in patients with obstructive sleep apnoea.

    PubMed

    Uygur, Firat; Tanrıverdi, Hakan; Can, Murat; Erboy, Fatma; Altınsoy, Bulent; Atalay, Figen; Ornek, Tacettin; Damar, Murat; Kokturk, Furuzan; Tor, Meltem

    2016-09-01

    Inflammation and oxidative stress play important roles in the pathogenesis of obstructive sleep apnoea syndrome (OSAS). Omentin is expressed in visceral adipose tissue and is associated with the inflammatory response. The aim of this study was to assess the relationship between OSAS and omentin based on a comparison of its serum levels at baseline and after 3 months of continuous positive airway pressure (CPAP) therapy. Ninety-six newly diagnosed OSAS patients and 31 non-apnoeic controls were enrolled in this study. Blood samples were obtained in the morning after polysomnography. Within the OSAS group, 30 patients were started on CPAP therapy and then reassessed clinically, including a blood test for serum omentin and other biochemical analysis, at 3 months. Serum omentin levels were significantly lower in the OSAS group than in the control group (27.7 ± 7.6 and 42.5 ± 5.2 ng/mL, P < 0.001). In the subgroup analysis, omentin concentrations were significantly lower in patients with severe OSAS than in those with mild/moderate OSAS (P < 0.001). Circulating omentin levels were significantly correlated with the apnoea-hypopnoea index (AHI), mean SaO2, oxygen desaturation index, and serum C-reactive protein levels. Treatment with CPAP resulted in a significant increase in circulating omentin levels after 3 months, from 22.7 ± 1.4 to 41.2 ± 3.3 ng/mL (P < 0.001). OSAS is associated with low serum omentin levels, and these levels can be reversed by effective CPAP treatment.

  6. Acceptance, effectiveness and safety of continuous positive airway pressure in acute stroke: a pilot study.

    PubMed

    Scala, Raffaele; Turkington, Peter M; Wanklyn, Peter; Bamford, John; Elliott, Mark W

    2009-01-01

    To evaluate the acceptance, effectiveness in preventing upper airways obstruction, and haemodynamic effects of continuous positive airway pressure (CPAP) in acute stroke. Twelve patients (4 M, and 8 F; mean (SD), 75.2 (5.5) years) within 48 h of acute stroke onset underwent: (1) sleep studies (1st night: auto-CPAP mode; 2nd night: diagnostic); (2) nocturnal non-invasive blood pressure studies (1st night during CPAP; 2nd night during spontaneous breathing (SB)); and (3) daytime cerebral blood flow velocity measurement in middle cerebral artery (FV) with transcranial Doppler during SB and with CPAP (5, 10, 15 cm H(2)O). Ninety percent, 60% and 50% of stroke patients had a respiratory disturbance index (RDI) of >or=5, >or=10 and >or=15 events per hour, respectively (18.2 (11.3)). CPAP acceptance was 84%; 42% used CPAP more than 6h and 42% between 1-3h with a mean use of CPAP of 5.2h (4.0). Compared to SB, CPAP reduced, though not significantly, RDI, time with SaO(2)<90%, mean blood pressure and mean blood pressure dips (10 mm Hg)/h. Compared with SB, any level of CPAP progressively and significantly reduced systolic and mean FV; drop in diastolic FV was significant at CPAP10 and CPAP15. The partial pressure of end-tidal CO(2) was significantly lowered by all levels of CPAP. According to this pilot study, CPAP is reasonably well tolerated by patients with acute stroke for at least one night. Despite its possible beneficial effect on obstructive sleep-disordered breathing and blood pressure variability, CPAP use in acute stroke should be still considered with caution due to possible harmful haemodynamic effects at higher pressures.

  7. Effect of Continuous Positive Airway Pressure on Stroke Rehabilitation: A Pilot Randomized Sham-Controlled Trial.

    PubMed

    Khot, Sandeep P; Davis, Arielle P; Crane, Deborah A; Tanzi, Patricia M; Lue, Denise Li; Claflin, Edward S; Becker, Kyra J; Longstreth, W T; Watson, Nathaniel F; Billings, Martha E

    2016-07-15

    Obstructive sleep apnea (OSA) predicts poor functional outcome after stroke and increases the risk for recurrent stroke. Less is known about continuous positive airway pressure (CPAP) treatment on stroke recovery. In a pilot randomized, double-blind, sham-controlled trial, adult stroke rehabilitation patients were assigned to auto-titrating or sham CPAP without diagnostic testing for OSA. Change in Functional Independence Measure (FIM), a measure of disability, was assessed between rehabilitation admission and discharge. Over 18 months, 40 patients were enrolled and 10 withdrew from the study: 7 from active and 3 from sham CPAP (p > 0.10). For the remaining 30 patients, median duration of CPAP use was 14 days. Average CPAP use was 3.7 h/night, with at least 4 h nightly use among 15 patients. Adherence was not influenced by treatment assignment or stroke severity. In intention-to-treat analyses (n = 40), the median change in FIM favored active CPAP over sham but did not reach statistical significance (34 versus 26, p = 0.25), except for the cognitive component (6 versus 2.5, p = 0.04). The on-treatment analyses (n = 30) yielded similar results (total FIM: 32 versus 26, p = 0.11; cognitive FIM: 6 versus 2, p = 0.06). A sham-controlled CPAP trial among stroke rehabilitation patients was feasible in terms of recruitment, treatment without diagnostic testing and adequate blinding-though was limited by study retention and CPAP adherence. Despite these limitations, a trend towards a benefit of CPAP on recovery was evident. Tolerance and adherence must be improved before the full benefits of CPAP on recovery can be assessed in larger trials. © 2016 American Academy of Sleep Medicine.

  8. Nocturnal continuous positive airway pressure in severe non-apneic asthma. A pilot study.

    PubMed

    D'Amato, Maria; Stanziola, Anna A; de Laurentiis, Guglielmo; Diana, Radicella; Russo, Cristian; Maniscalco, Mauro; D'Amato, Gennaro; Sofia, Matteo

    2014-10-01

    It has been demonstrated that brief periods of nocturnal continuous positive airway pressure (nCPAP) reduce airway reactivity in animal models and in patients with asthma. The effects of nCPAP in severe uncontrolled non-apneic asthmatic patients are not well known. In this open pilot study, we aimed to assess the effect nCPAP on peak flow (PEF) variability and asthma control in this type of patients. CPAP was applied to 10 patients with severe long-standing asthma without obstructive sleep apnea for seven consecutive nights. CPAP was titrated in auto setting and applied to the patients. Daily PEF, was measured from 2 weeks before the intervention to 2 weeks after the end of nCPAP treatment. PEF amplitude and PEF morning dip (MD) over 24-h periods averaged over 1 week were calculated as indexes of PEF variability. Asthma control test (ACT) and European quality of life (EuroQol) questionnaire were measured at baseline and after 1 month, and at baseline and at the end of CPAP period, respectively. The PEF amplitude significantly decreased both during CPAP period and in the first week after nCPAP discontinuation as compared with the baseline (19.8 ± 7.5%, 23.9 ± 9.1% and 28.9 ± 11.5%, respectively, always P < 0.05). PEF MD significantly decreased during nCPAP in comparison with the baseline (P < 0.001). The ACT and EuroQol significantly improved after nCPAP in comparison with the basal value. In this preliminary report, brief period of nCPAP reduces PEF variability and improves control in severe non-apneic asthma at a short-term evaluation. Further studies with longer-term evaluation and larger number of patients are warranted. © 2013 John Wiley & Sons Ltd.

  9. Position-gram - A Visual Method for Detecting Transient Events in Continuous GPS Time Series

    NASA Astrophysics Data System (ADS)

    Jiang, Y.; Wdowinski, S.

    2008-12-01

    Continuous Global Positioning System (CGPS) time series provide excellent observations for detecting crustal deformation at various length and time-scales. With the increasing precision and length of the time series, new modes of deformation, such as slow slip events and sub-continental scale changes in crustal velocities, can be detected. However, non-tectonic surface movements and measurement noise limit our ability to detect and quantify tectonic-induced transient deformation. Two common methods for reducing noise level in CGPS time series, spatial filtering and periodic seasonal fitting, significantly improve the secular tectonic signal, but fail when transient deformation events are embedded in the time series. We developed a new visually-based method for detecting transient events in CGPS time series. The development was inspired by wavelet analysis presentations that use color to present quantitative information about relationships between time and frequency domains. Here we explore the relationship between time and space domains. The displacement information is color coded according to spline fitting of each time series. This 3-D information (time, space, and displacement in color) allows easy detection of spatio-temporal patterns, which can serve as indicators for transient deformation events. We tested the new method with CGPS time series from three regions with different spatial scales: the Pacific Northwest, Southern California, and the entire continental US. The Pacific Northwest study confirmed that our proposed methodology is capable of detecting transient events and mapping their lateral distribution. The Southern California study detected a new transient event near the intersection of the San Andreas and San Jacinto faults, far from any known creeping fault segments. Finally the continental scale analysis revealed regionally correlated crustal movements in the Basin and Range and California, but uncorrelated with sites in eastern US. Such signal

  10. Noninvasive continuous positive airway pressure delivered using a pediatric helmet in dogs recovering from general anesthesia.

    PubMed

    Staffieri, Francesco; Crovace, Antonio; De Monte, Valentina; Centonze, Paola; Gigante, Giulio; Grasso, Salvatore

    2014-01-01

    To evaluate the feasibility and efficacy of noninvasive continuous positive airway pressure (CPAP) administered with a pediatric helmet in healthy dogs recovering from general anesthesia. Randomized, cross-over, clinical study. University teaching hospital. Fifteen healthy female, client-owned dogs recovering from general anesthesia following elective ovariohysterectomy. All dogs received the same standardized anesthetic protocol (acepromazine, morphine, propofol, and isoflurane in oxygen). After extubation, a pediatric helmet was placed on all dogs and connected to a venturi valve supplied with medical air. In all patients, the gas flow was set to 50 L/minute and the FiO2 to 0.21. Dogs received the following sequence of treatments, each lasting 20 minutes: 0 CPAP (pre-CPAP), CPAP of 5 cm H2 O (CPAP), and again 0 CPAP (post-CPAP). During the entire study, the following data were collected: pressure and FiO2 inside the helmet, mean arterial pressure, respiratory rate, heart rate, sedation score (0 = awake, 10 = deep sedation), and tolerance to the helmet (0 = excellent, 4 = poor). At the end of each phase, an arterial blood sample was sampled. As compared with the pre-CPAP and the post-CPAP periods, during the CPAP period, the PaCO2 , alveolar-arterial oxygen gradient (P[A-a]O2 ), and respiratory rate significantly decreased. The PaO2 was higher at CPAP (105.6 ± 4.0 mm Hg) compared with pre-CPAP (80.6 ± 6.9 mm Hg) and post-CPAP (86.7 ± 5.8 mm Hg). Tolerance and sedation scores during the CPAP period were not different from those in the pre-CPAP and post-CPAP periods. Noninvasive CPAP applied through a helmet is a feasible and effective supportive technique in dogs recovering from general anesthesia. © Veterinary Emergency and Critical Care Society 2014.

  11. Continuous positive airway pressure administered via face mask in tranquilized dogs.

    PubMed

    Briganti, Angela; Melanie, Pierre; Portela, Diego; Breghi, Gloria; Mama, Khursheed

    2010-10-01

    To evaluate the tolerance of a continuous positive airway pressure (CPAP) mask in tranquilized dogs and compare PaO₂ in arterial blood in dogs receiving oxygen with a regular face mask or CPAP mask set to maintain a pressure of 2.5 or 5 cm H₂O. Prospective, randomized clinical study. University teaching hospital. Sixteen client-owned dogs without evidence of cardiopulmonary disease were studied. Eight animals were randomly assigned to each of 2 treatment groups: group A received 2.5 cm H₂O CPAP and group B received 5 cm H₂O CPAP after first receiving oxygen (5 L/min) by a regular face mask. Animals were tranquilized with acepromazine 0.05 mg/kg, i.v. and morphine 0.2 mg/kg, i.m.. An arterial catheter was then placed to facilitate blood sampling for pHa, PaO₂, and PaCO₂ determinations before and after treatments. Direct mean arterial pressure, heart rate, respiratory rate, and temperature were also recorded after each treatment. CPAP administration was well tolerated by all animals. The mean arterial pressure, heart rate, respiratory rate, temperature, PaCO₂, and pHa, did not differ at any time point between groups. Differences were seen in oxygenation; in group A, PaO₂ significantly increased from a mean of 288.3 ± 47.5 mm Hg with a standard mask to a mean of 390.3 ± 65.5 mm Hg with the CPAP mask and in group B, PaO₂ increased similarly from 325.0 ± 70.5 to 425.2 ± 63.4 mm Hg (P<0.05); no differences were detected between the 2 CPAP treatments. In healthy tranquilized dogs noninvasive CPAP is well tolerated and increases PaO₂ above values obtained when using a regular face mask. © Veterinary Emergency and Critical Care Society 2010.

  12. Effects of Use of a Continuous Positive Airway Pressure Device on Glaucoma

    PubMed Central

    Ulusoy, Seckin; Erden, Meltem; Dinc, Mehmet Emre; Yavuz, Nurdogan; Caglar, Erdem; Dalgic, Abdullah; Erdogan, Coskun

    2015-01-01

    Background The aim of this study was to investigate the prevalence of glaucoma in obstructive sleep apnea syndrome (OSAS) and to determine the efficacy of the equipment used in the treatment of this disease. Material/Methods In this cross-sectional study, 38 patients with OSAS used the continuous positive airway pressure (CPAP) device (Group 1) and 32 patients with OSAS refused CPAP device (Group 2). Thirty-six patients did not have OSAS (Group 3). Results Patient age, gender, height, weight, and neck circumference did not differ among groups (p>0.05); and the apnea-hypopnea index (AHI) and respiratory disturbance index (RDI) values did not differ between Groups 1 and 2 (p>0.05). Vision and pachymetric values did not differ among groups (p>0.05). The IOP was significantly higher in Group 2 than in Group 1 (p<0.05) but did not differ between Groups 1 and 3 (p>0.05). The fundus C/D ratio was significantly higher (p<0.05) in Group 2 than in the other groups but did not differ between Groups 1 and 3 (p>0.05). In Group 1, 2, and 3, 5.2%, 12.5%, and 0%, respectively, of patients had glaucoma. Conclusions OSAS should be considered a significant risk factor for glaucoma. Eye tests may help to identify individuals with undiagnosed OSAS, and such testing of patients with diagnosed OSAS may allow early detection of glaucoma and referral of such patients for CPAP therapy to prevent development of complications. PMID:26547930

  13. [Effect of the external nasal dilator breathe right and nasal cycle influence].

    PubMed

    Yoshinami, Hiroyoshi; Takegoshi, Hideki; Kikuchi, Shigeru; Iinuma, Toshitaka

    2005-11-01

    The external nasal dilator Breathe Right is a nonprescription disposable mechanical device worn over the bridge of the nose that supports the outer walls of the nasal vestibule to increase cross-sectional nasal valve area and enhance air flow through the nose. When worn, the device applies a gentle outward pull to the outside walls of the nasal vestibule that helps prevent collapse of the lateral walls of the nasal vestibule. The device appears similar to an adhesive bandage with two polyester springs attached lengthwise to the nonadhesive side of the backing material. The form of the external nose varies significantly between racial groups and some comment is possible about the form of the nasal valve, i.e., Caucasian noses are leptorrhine, Negroid noses platyrrhine, and Oriental noses intermediate. A question exists about whether Breathe Right is as effective in Japanese as in Caucasians against nasal obstruction. We measured the effect by acoustic rhinometry in 35 healthy subjects. We measured 2 cross-sectional areas-the I-notch and C-notch-and 3 nasal volumes-V(0-1), from 0 to 1 cm corresponding to the I-notch, V(1-3), from 1 to 3cm corresponding to the C notch, and V (3-6), from 3 to 6cm. We studied the influence of the nasal cycle on the effect of Breathe Right in the nasal cavity. We evaluated subjects in a stable sitting position before applying Breathe Right, after using 5 minutes, and in a free interval of 25 minutes following. The experiment was repeated 10 times. We found that Breathe Right increases the nasal volume especially in V(1-3) and the cross-sectional area especially in the C-notch. Interestingly, the change in the C-notch decreased gradually with time. One possible mechanism may be the change in compliance between the skin under the Breathe Right and the nasal mucous membrane. The nasal cycle did not significantly influence the effect of Breathe Right.

  14. Nasal corticosteroid sprays

    MedlinePlus

    ... best for decreasing symptoms during that season. Several brands of nasal corticosteroid sprays are available. They all ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  15. Budesonide Nasal Spray

    MedlinePlus

    ... by an allergy to pollen, mold, dust, or pets). Budesonide nasal spray should not be used to ... disposed of in special ways to ensure that pets, children, and other people cannot consume them. However, ...

  16. Cyanocobalamin Nasal Gel

    MedlinePlus

    ... B12 can cause anemia (condition in which the red blood cells do not bring enough oxygen to the organs) ... be treated with vitamin B12 injections. After the red blood cells have returned to normal, cyanocobalamin nasal gel can ...

  17. Nasal fracture (image)

    MedlinePlus

    A nasal fracture is a break in the bone over the ridge of the nose. It usually results from a blunt ... and is one of the most common facial fracture. Symptoms of a broken nose include pain, blood ...

  18. Chapter 6: Nasal polyps.

    PubMed

    Settipane, Russell A; Peters, Anju T; Chiu, Alexander G

    2013-01-01

    Nasal polyps occur in 1-4% of the population, usually occurring in the setting of an underlying local or systemic disease. The most common associated condition is chronic rhinosinusitis (CRS). A high prevalence of nasal polyps is also seen in allergic fungal rhinosinusitis, aspirin-exacerbated respiratory disease, Churg-Strauss syndrome, and cystic fibrosis. In the setting of CRS, nasal polyps are not likely to be cured by either medical or surgical therapy; however, control is generally attainable. The best medical evidence supports the use of intranasal corticosteroids for maintenance therapy and short courses of oral corticosteroids for exacerbations. The evidence for short- and long-term antibiotics is much less robust. For patients with symptomatic nasal polyposis nonresponsive to medical therapies, functional endoscopic sinus surgery provides an adjunctive therapeutic option.

  19. Nasal packing and stenting

    PubMed Central

    Weber, Rainer K.

    2011-01-01

    Nasal packs are indispensable in ENT practice. This study reviews current indications, effectiveness and risks of nasal packs and stents. In endoscopic surgery, nasal packs should always have smooth surfaces to minimize mucosal damage, improve wound healing and increase patient comfort. Functional endoscopic endonasal sinus surgery allows the use of modern nasal packs, since pressure is no longer required. So called hemostatic/resorbable materials are a first step in this direction. However, they may lead to adhesions and foreign body reactions in mucosal membranes. Simple occlusion is an effective method for creating a moist milieu for improved wound healing and avoiding dryness. Stenting of the frontal sinus is recommended if surgery fails to produce a wide, physiologically shaped drainage path that is sufficiently covered by intact tissue. PMID:22073095

  20. Saline nasal washes

    MedlinePlus

    ... Be sure you only use distilled, boiled, or filtered water. While rare, some tap water may contain small ... pot or nasal bulb with distilled, boiled, or filtered water after every use and let it dry. Use ...

  1. Exhaled nitric oxide and nasal tryptase are associated with wheeze, rhinitis and nasal allergy in primary school children.

    PubMed

    De Prins, Sofie; Marcucci, Francesco; Sensi, Laura; Van de Mieroop, Els; Nelen, Vera; Nawrot, Tim S; Schoeters, Greet; Koppen, Gudrun

    2014-09-01

    Rhinitis and asthma are the most common respiratory diseases in children. We assessed whether airway inflammation markers were associated with nasal allergies and self-reported symptoms of wheeze and rhinitis in 130 children 6-12 year old in an epidemiological context. Independent of sex and age, the fraction of exhaled nitric oxide (FeNO) and nasal mast cell (MC) activation (tryptase ≥ 5 ng/mL) were positively associated with wheeze, rhinitis and with nasal allergy. Nasal eosinophil cationic protein (ECP) and exhaled breath condensate (EBC) markers (pH, 8-isoprostane, interleukin-1β) were not associated with symptoms or with nasal allergy. In conclusion, FeNO and nasal tryptase reflect allergic inflammation in the respiratory system.

  2. Nasal and exhaled nitric oxide in chronic rhinosinusitis with polyps.

    PubMed

    Jeong, Jin Hyeok; Yoo, Han Seok; Lee, Seung Hwan; Kim, Kyung Rae; Yoon, Ho Joo; Kim, Sang Heon

    2014-01-01

    The ciliary epithelial cells in the paranasal sinuses produce nasal nitric oxide (NO) continuously and plays a variety of roles in the paranasal sinuses. The purpose of this study was to assess whether we can use the levels of nasal NO (nNO) and exhaled NO (eNO) as a tool for evaluation in chronic rhinosinusitis (CRS) with nasal polyp patients. We used chemiluminescent NO analyzer to measure nNO and eNO among normal controls (32) and CRS with polyp (30) and CRS with polyp and allergic rhinitis patients (27) and compared it with various clinical symptoms, laboratory data, and computed tomography (CT) scores. Levels of nNO were significantly lower in patients with CRS with polyps (88.5 ± 54.7 ppb) compared with controls (241.0 ± 89.5 ppb). Levels of nNO in CRS with polyps and allergic rhinitis (167.0 ± 47.6 ppb) were significantly higher than CRS with polyps and lower than controls. A significant inverse relationship was observed between nNO and sinus CT scores, severity of nasal obstruction, and purulent rhinorrhea in CRS with polyps. Low values of nNO separated well patients with CRS with polyps, and the cutoff value of <163 ppb was associated with the best combination of specificity (93%) and sensitivity (81%). A significant positive relationship was observed between eNO and CT scores. The nNO could be used for another screening of CRS with polyps for the more severe phenotypes, which may eventually have to be treated with surgery.

  3. Long-term continuous positive airway pressure therapy improves cardiac autonomic tone during sleep in patients with obstructive sleep apnea.

    PubMed

    Palma, Jose-Alberto; Iriarte, Jorge; Fernandez, Secundino; Alegre, Manuel; Valencia, Miguel; Artieda, Julio; Urrestarazu, Elena

    2015-08-01

    Cardiac autonomic tone after long-term continuous positive airway pressure therapy in patients with obstructive sleep apnea remains unexplored. Thirty patients with obstructive sleep apnea (14 with moderate and 16 with severe obstructive sleep apnea) were studied during a baseline polysomnographic study, after a full night of acute continuous positive airway pressure treatment, and after long-term (~2 years) chronic continuous positive airway pressure therapy. Twenty age- and gender-matched controls with baseline sleep study were selected for comparison purposes. Cross-spectral analysis and the low-frequency (LF) and high-frequency (HF) components of the heart rate variability were computed separately over 10-min ECG epochs during rapid eye movement sleep, non-rapid eye movement sleep, and wakefulness. During the baseline study, obstructive sleep apnea patients exhibited increased LF, decreased HF, and increased LF/HF ratio during sleep when compared to controls. In a multiple regression model, the mean oxygen saturation explained the increased LF during rapid and non-rapid eye movement sleep in obstructive sleep apnea patients. Acute continuous positive airway pressure therapy decreased the LF modulations and the LF/HF ratio and increased the HF modulations during sleep in patients with severe obstructive sleep apnea. Long-term continuous positive airway pressure therapy decreased LF modulations and LF/HF ratio with increased HF modulations during sleep in patients with moderate and severe obstructive sleep apnea. Long-term continuous positive airway pressure reduces the sympathovagal imbalance in patients with moderate and severe obstructive sleep apnea, both during rapid and non-rapid eye movement sleep. Continuous positive airway pressure seems to exert its changes in cardiac autonomic modulation by decreasing the burden of nocturnal hypoxia.

  4. Diastolic function and functional capacity after a single session of continuous positive airway pressure in patients with compensated heart failure

    PubMed Central

    Bussoni, Marjory Fernanda; Guirado, Gabriel Negretti; Matsubara, Luiz Shiguero; Roscani, Meliza Goi; Polegato, Bertha Furlan; Minamoto, Suzana Tanni; Bazan, Silméia Garcia Zanati; Matsubara, Beatriz Bojikian

    2014-01-01

    OBJECTIVE: The effects of acute continuous positive airway pressure therapy on left ventricular diastolic function and functional capacity in patients with compensated systolic heart failure remain unclear. METHODS: This randomized, double-blind, placebo-controlled clinical trial included 43 patients with heart failure and a left ventricular ejection fraction <0.50 who were in functional classes I-III according to the New York Heart Association criteria. Twenty-three patients were assigned to continuous positive airway pressure therapy (10 cmH2O), while 20 patients received placebo with null pressure for 30 minutes. All patients underwent a 6-minute walk test (6MWT) and Doppler echocardiography before and immediately after intervention. Clinicaltrials.gov: NCT01088854. RESULTS: The groups had similar clinical and echocardiographic baseline variables. Variation in the diastolic function index (e′) after intervention was associated with differences in the distance walked in both groups. However, in the continuous positive airway pressure group, this difference was greater (continuous positive airway pressure group: Δ6MWT = 9.44+16.05×Δe′, p = 0.002; sham group: Δ6MWT = 7.49+5.38×Δe′; p = 0.015). There was a statistically significant interaction between e′ index variation and continuous positive airway pressure for the improvement of functional capacity (p = 0.020). CONCLUSIONS: Continuous positive airway pressure does not acurately change the echocardiographic indexes of left ventricle systolic or diastolic function in patients with compensated systolic heart failure. However, 30-minute continuous positive airway pressure therapy appears to have an effect on left ventricular diastolic function by increasing functional capacity. PMID:24838902

  5. Pathophysiology of nasal congestion

    PubMed Central

    Naclerio, Robert M; Bachert, Claus; Baraniuk, James N

    2010-01-01

    Nasal congestion is a common symptom in rhinitis (both allergic and nonallergic), rhinosinusitis and nasal polyposis. Congestion can also be caused by physical obstruction of nasal passages and/or modulation of sensory perception. Mucosal inflammation underlies many of the specific and interrelated factors that contribute to nasal congestion, as well as other symptoms of both allergic rhinitis and rhinosinusitis. A wide range of biologically active agents (eg, histamine, tumor necrosis factor-α, interleukins, cell adhesion molecules) and cell types contribute to inflammation, which can manifest as venous engorgement, increased nasal secretions and tissue swelling/edema, ultimately leading to impaired airflow and the sensation of nasal congestion. Inflammation-induced changes in the properties of sensory afferents (eg, expression of peptides and receptors) that innervate the nose can also contribute to altered sensory perception, which may result in a subjective feeling of congestion. Increased understanding of the mechanisms underlying inflammation can facilitate improved treatment selection and the development of new therapies for congestion. PMID:20463823

  6. Correlation of nasal inflammation and nasal airflow with forced expiratory volume in 1 second in patients with perennial allergic rhinitis and asthma.

    PubMed

    Ciprandi, Giorgio; Cirillo, Ignazio; Vizzaccaro, Andrea; Milanese, Manlio; Tosca, Maria Angela

    2004-12-01

    Allergic rhinitis and asthma are frequently associated and are characterized by TH2-dependent inflammation. Nasal and bronchial obstruction largely depend on allergic inflammation. To evaluate the relationships among nasal eosinophil counts, interleukin 4 (IL-4) and interferon-gamma (IFN-gamma) levels, nasal airflow, and forced expiratory volume in 1 second (FEV1) in patients with perennial allergic rhinitis and asthma. Eight men and 7 women (mean +/- SD age, 24.8 +/- 4.7 years) with perennial allergic rhinitis and asthma were evaluated. All 15 patients had a moderate-to-severe grade of nasal obstruction. Total symptom score, rhinomanometry, nasal lavage, nasal scraping, and spirometry were evaluated in all patients. Eosinophils were counted using conventional staining; IL-4 and IFN-gamma levels were measured by immunoassay in fluids recovered from nasal lavage. Significant positive relationships were demonstrated between eosinophil infiltration and IL-4 levels, nasal airflow and IFN-gamma levels, FEV1 and IFN-gamma levels, and nasal airflow and FEV1 (P < .001 for all). Significant negative relationships were demonstrated between eosinophil infiltration and IFN-gamma levels, IL-4 and IFN-gamma levels, eosinophil infiltration and nasal airflow, IL-4 values and nasal airflow, nasal eosinophil counts and FEV1, and IL-4 values and FEV1 (P < .001 for all). There is a close association between TH2 cytokines and eosinophil infiltration in the nose. There is also clear evidence concerning the relationships among eosinophil infiltration, IL-4 and IFN-gamma levels, and nasal airflow. Nasal eosinophil, IL-4, and IFN-gamma levels correlate with FEV1. Finally, nasal airflow is related to FEV1. These findings constitute the first evidence of a relationship between TH2-related nasal inflammation and nasal and bronchial airflow in patients with perennial allergic rhinitis and asthma.

  7. Titanium Mesh Nasal Repair without Nasal Lining.

    PubMed

    Zenga, Joseph; Kao, Katherine; Chen, Collin; Gross, Jennifer; Hahn, Samuel; Chi, John J; Branham, Gregory H

    2017-02-01

    The objective of this study was to describe outcomes for patients who underwent titanium mesh reconstruction of full-thickness nasal defects without internal lining repair. This is a retrospective cohort study. Patients with through-and-through nasal defects were identified at a single academic institution between 2008 and 2016. Nasal reconstruction was performed with either titanium mesh and external skin reconstruction without repair of the intranasal lining or traditional three-layer closure. Five patients underwent titanium mesh reconstruction and 11 underwent traditional three-layer repair. Median follow-up was 11 months (range, 2-66 months). The only significant difference between groups was older age in patients undergoing titanium reconstruction (mean, 81 vs. 63 years; difference of 18; 95% confidence interval [CI], 4-32 years). Defect extent including overall size and structures removed was similar between groups (p > 0.05). Paramedian forehead flap was the most common external reconstruction in both groups (100% for titanium mesh and 73% for three-layer closure). Time under anesthesia was significantly shorter for titanium mesh reconstruction (median, 119 vs. 314 minutes; difference of 195; 95% CI, 45-237). Estimated blood loss and length of hospital stay were similar between groups (p > 0.05). Complication rates were substantial although not significantly different, 40 and 36% in titanium and three-layer reconstruction, respectively (p > 0.05). All patients with complications after titanium reconstruction had prior or postoperative radiotherapy. Titanium mesh reconstruction of through-and-through nasal defects can successfully be performed without reconstruction of the intranasal lining, significantly decreasing operative times. This reconstructive technique may not be suitable for patients who undergo radiotherapy.

  8. Learning from Public Television and the Web: Positioning Continuing Education as a Knowledge Portal.

    ERIC Educational Resources Information Center

    Vedro, Steven R.

    1999-01-01

    Digital convergence--the merging of television and computing--challenges localized monopolies of public television and continuing education. Continuing educators can reposition themselves in the electronic marketplace by serving as an educational portal, bringing their strengths of "brand recognition," local customer base, and access to…

  9. Learning from Public Television and the Web: Positioning Continuing Education as a Knowledge Portal.

    ERIC Educational Resources Information Center

    Vedro, Steven R.

    1999-01-01

    Digital convergence--the merging of television and computing--challenges localized monopolies of public television and continuing education. Continuing educators can reposition themselves in the electronic marketplace by serving as an educational portal, bringing their strengths of "brand recognition," local customer base, and access to…

  10. Cost-effectiveness of Out-of-Hospital Continuous Positive Airway Pressure for Acute Respiratory Failure

    PubMed Central

    Thokala, Praveen; Goodacre, Steve; Ward, Matt; Penn-Ashman, Jerry; Perkins, Gavin D.

    2015-01-01

    Study objective We determine the cost-effectiveness of out-of-hospital continuous positive airway pressure (CPAP) compared with standard care for adults presenting to emergency medical services with acute respiratory failure. Methods We developed an economic model using a United Kingdom health care system perspective to compare the costs and health outcomes of out-of-hospital CPAP to standard care (inhospital noninvasive ventilation) when applied to a hypothetical cohort of patients with acute respiratory failure. The model assigned each patient a probability of intubation or death, depending on the patient’s characteristics and whether he or she had out-of-hospital CPAP or standard care. The patients who survived accrued lifetime quality-adjusted life-years (QALYs) and health care costs according to their age and sex. Costs were accrued through intervention and hospital treatment costs, which depended on patient outcomes. All results were converted into US dollars, using the Organisation for Economic Co-operation and Development purchasing power parities rates. Results Out-of-hospital CPAP was more effective than standard care but was also more expensive, with an incremental cost-effectiveness ratio of £20,514 per QALY ($29,720/QALY) and a 49.5% probability of being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold. The probability of out-of-hospital CPAP’s being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold depended on the incidence of eligible patients and varied from 35.4% when a low estimate of incidence was used to 93.8% with a high estimate. Variation in the incidence of eligible patients also had a marked influence on the expected value of sample information for a future randomized trial. Conclusion The cost-effectiveness of out-of-hospital CPAP is uncertain. The incidence of patients eligible for out-of-hospital CPAP appears to be the key determinant of cost-effectiveness. PMID:25737210

  11. Comparison of the effects of continuous positive airway pressure, oral appliance and exercise training in obstructive sleep apnea syndrome.

    PubMed

    Schütz, Teresa Cristina Barros; Cunha, Thays Crosara Abrahão; Moura-Guimaraes, Thais; Luz, Gabriela Pontes; Ackel-D'Elia, Carolina; Alves, Eduardo da Silva; Pantiga, Gilberto; Mello, Marco Tulio de; Tufik, Sergio; Bittencourt, Lia

    2013-01-01

    There are several treatments for obstructive sleep apnea syndrome, such as weight loss, use of an oral appliance and continuous positive airway pressure, that can be used to reduce the signs and symptoms of obstructive sleep apnea syndrome. Few studies have evaluated the effectiveness of a physical training program compared with other treatments. The aim of this study was to assess the effects of physical exercise on subjective and objective sleep parameters, quality of life and mood in obstructive sleep apnea patients and to compare these effects with the effects of continuous positive airway pressure and oral appliance treatments. Male patients with moderate to severe obstructive sleep apnea and body mass indices less than 30 kg/m2 were randomly assigned to three groups: continuous positive airway pressure (n = 9), oral appliance (n = 9) and physical exercise (n = 7). Polysomnographic recordings, blood samples and daytime sleepiness measurements were obtained prior to and after two months of physical exercise or treatment with continuous positive airway pressure or an oral appliance. Clinicaltrials.gov: NCT01289392 RESULTS: After treatment with continuous positive airway pressure or an oral appliance, the patients presented with a significant reduction in the apnea-hypopnea index. We did not observe changes in the sleep parameters studied in the physical exercise group. However, this group presented reductions in the following parameters: T leukocytes, very-low-density lipoprotein and triglycerides. Two months of exercise training also had a positive impact on subjective daytime sleepiness. Our results suggest that isolated physical exercise training was able to modify only subjective daytime sleepiness and some blood measures. Continuous positive airway pressure and oral appliances modified the apnea-hypopnea index.

  12. Respiratory support with heated humidified high flow nasal cannula in preterm infants.

    PubMed

    Jeon, Ga Won

    2016-10-01

    The incidence of bronchopulmonary dysplasia (BPD) has not decreased over the last decade. The most important way to decrease BPD is by weaning the patient from the ventilator as soon as possible in order to reduce ventilator-induced lung injury that underlies BPD, and by using a noninvasive ventilator (NIV). Use of a heated, humidified, high flow nasal cannula (HHHFNC), which is the most recently introduced NIV mode for respiratory support in preterm infants, is rapidly increasing in many neonatal intensive care units due to the technical ease of use without sealing, and the attending physician's preference compared to other NIV modes. A number of studies have shown that nasal breakdown and neonatal complications were lower when using a HHHFNC than when using nasal continuous positive airway pressure (nCPAP), or nasal intermittent positive pressure ventilation. The rates of extubation failure during respiratory support were not different between patients who used HHHFNC and nCPAP. However, data from the use of HHHFNC as the initial respiratory support "after birth", particularly in extremely preterm infants, are lacking. Although the HHHFNC is efficacious and safe, large randomized controlled trials are needed before the HHHFNC can be considered an NIV standard, particularly for extremely preterm infants.

  13. Objectivating nasality in healthy and velopharyngeal insufficient children with the Nasalance Acquisition System (NasalView). Defining minimal required speech tasks assessing normative values for Dutch language.

    PubMed

    Hogen Esch, Thijs T; Dejonckere, Philippe H

    2004-08-01

    (1) To define normative nasalance data for Dutch language with "the NasalView System", and obtain a reference for normality when nasality is evaluated in children. (2) To investigate the minimal number of required speech tasks for a reliable nasalance measurement. 55 children (30 normal and 25 velopharyngeal insufficient), aged between 4 and 11 were included. All children had to read or repeat two Dutch passages ((one with a normal amount of nasal consonants (normal passage) and one with none (nonnasal passage)). Further, one normal and one velopharyngeal insufficient subject read a passage in repetition to test the NasalViews reproducibility: (1) For both passages, group means (GM) and standard deviations (S.D.) were used to compute "pathological nasalance boundaries" [GM +/- (2 x S.D.)], in combination with the coefficient of variation (CV), sensitivity, specificity and positive predictive values. (2) With ANOVA all sentences within each passage were tested for significant differences in nasalance. (1) The pathological boundaries were 28.6-41.4% (GM: 35.0) and 21.4-34.7% (GM: 28.1), for the normal and nonnasal passage, respectively. For the normal passage a sensitivity of 96%, a specificity of 93% and a positive predictive value of 92% was computed. For the nonnasal passage these parameters were 96, 95 and 96%, respectively. Intra subject CVs of 3.6% (normal subject) and 1.5% (VI subject) showed good reproducibility of measurements. (2) Within the normal passage only the third sentence was significantly different in nasalance, compared to the entire passage (31.2% versus 35.0%). Within the nonnasal passage the second and fifth sentences were significantly different (23.8 and 24.8% versus 28.1%). However, the individual nonsignificantly different sentences showed a higher variation in nasalance compared to the entire passages. The NasalView System seems to be reliable and quantifies valid nasalance values when nasality is evaluated. Within both passages high

  14. [Do the effects of posture change and climbing stairs on nasal patency differ in acoustic rhinometry?].

    PubMed

    Gudziol, H; Stadeler, M

    2008-04-01

    Divergent results concerning nasal patency during positional body changes are found using acoustic rhinometry. Only small numbers of healthy subjects have been tested. The present study shall examine a larger number of healthy subjects providing a basis for later findings in sick nasal mucosa. 40 healthy subjects (20 female, 20 male; average age: 32.8+/-13.8 years) without any nasal and cardiovascular disease were examined. Using acoustic rhinometry, the total nasal volume (Vt) and the total minimum nasal cross-sectional area (Ft) were calculated from the collected data. Six measurements were made: in sedentary rest position, standing, lying dorsally, after standing up, after climbing stairs and in iteration in sedentary rest position. In healthy subjects, the total nasal volume (i. e. the nasal respiration space of the two nasal passages) did not change during standing and lying, after rapid standing up and in a repeat measurement 5 hours later. After climbing stairs, the nasal mucosa decongested significantly, chiefly dorsal to the isthmus nasi. The birhine partial volume (V2) increased by an average of 33 %. Positional changes have no effect on healthy nasal mucosa. Total nasal respiration is unaffected. The reaction of sick nasal mucosa must be established in future investigations.

  15. Perceptual Processing of Mandarin Nasals by L1 and L2 Mandarin Speakers

    ERIC Educational Resources Information Center

    Lai, Yi-hsiu

    2012-01-01

    Nasals are cross-linguistically susceptible to change, especially in the syllable final position. Acoustic reports on Mandarin nasal production have recently shown that the syllable-final distinction is frequently dropped. Few studies, however, have addressed the issue of perceptual processing in Mandarin nasals for L1 and L2 speakers of Mandarin…

  16. Muscle-building therapy in treatment of nasal valve collapse.

    PubMed

    Vaiman, Michael; Eviatar, Ephraim; Segal, Samuel

    2004-09-01

    The purpose of this paper is to describe the outcome of muscle-building therapy for nasal muscles in cases of nasal valve stenosis or collapse. The present study was performed to investigate the best way to combine transcutaneous and intranasal surface electromyography (sEMG) biofeedback training of muscles involved in nasal valve function with a home exercise program and electric stimulation of nasal muscles. A randomized pilot study of 3 groups of patients (n1=12, n2=12, n3=10; total 34 patients) presenting with symptoms of obstructed nasal breathing was conducted. All selected patients demonstrated nasal valve stenosis with a positive Cottler maneuver and clinically evident nasal valve collapse. Follow-up ranged from 8 to 12 months. Treatment for Group 1 included transcutaneous and intranasal electric stimulation of nasal muscles only. Treatment for Group 2 included biofeedback training and home exercise program of specific nasal movements, and treatment for Group 3 included surface and intranasal EMG biofeedback assisted specific strategies for nasal muscle education, home exercises and electric stimulation. All patients in these groups exhibited subjective improvement. For Group 3, in 80% the improvement was proved objectively; for Group 2, in 75% the improvement was proved objectively; for Group 1, in 58,33% the improvement was proved objectively. We found no significant difference between the results in Groups 3 and 2 and poorer results in Group 1. Relieve of nasal valve stenosis and collapse can be achieved with a complex muscle-building therapy as described. It helps a significant cohort of patients with symptoms of obstructed nasal breathing to avoid surgical intervention. Electric stimulation of the muscles does not contribute significantly in achieving of good results.

  17. Chondrosarcoma of the nasal septum

    PubMed Central

    Bahgat, Mohammed; Bahgat, Yassin; Bahgat, Ahmed; Elwany, Yasmine

    2012-01-01

    Chondrosarcoma of the nasal septum is a rare malignancy. When it occurs, early diagnosis is difficult because patients generally present with common, non-specific sinonasal complaints. This is the report of a 62-year-old woman who presented with a 1-month history of nasal obstruction, headache and anosmia. Nasal endoscopy showed a nasal mass obstructing both nasal cavities not separable from the septum. A wedge biopsy of the nasal mass was taken. Histopathology was suggestive of chondrosarcoma. The tumour was removed by an endoscopic approach. The clinical presentation, diagnosis and treatment of this case as well as a review of the literature are discussed. PMID:22669930

  18. Effect of Nasal CPAP on SIRT1 and Endothelial Function in Obstructive Sleep Apnea Syndrome.

    PubMed

    Chen, Wei-Ji; Liaw, Shwu-Fang; Lin, Ching-Chi; Chiu, Chung-Hsin; Lin, Mei-Wei; Chang, Feng-Ting

    2015-12-01

    Sirtuin 1 (SIRT1), a histone/protein deacetylase, has been implicated in aging, metabolism, and stress resistance. SIRT1 regulates endothelial nitric oxide (NO) synthase, restores NO availability, and is involved in different aspects of cardiovascular disease. The aim of this study was to evaluate any abnormalities with regard to SIRT1 protein level in the blood, SIRT1 activity, and impaired endothelial function in patients with obstructive sleep apnea syndrome (OSAS). We also investigated whether or not OSAS patients who received nasal continuous positive airway pressure (CPAP) treatment showed improvements in the levels of SIRT1. Thirty-five patients with moderately severe to severe OSAS who requested nasal CPAP treatment and 20 healthy controls were prospectively enrolled. The SIRT1 protein levels in blood and its activity, and the serum levels of nitric oxide derivative (NO x ) were assessed. All subjects participated in sleep studies, which were repeated 3 months after nasal CPAP treatment in the patients with OSAS. In the patients with OSAS, the level of SIRT1 in the blood, its activity, and that of NO x was lower than those of normal subjects before nasal CPAP treatment. After nasal CPAP treatment, the level of SIRT1 in the blood and its activity increased from 0.55 ± 0.32 pg/μg of total protein and 3085.53 ± 1071.57 arbitrary fluorescence units (AFUs)/μg of total protein to 1.13 ± 0.43 pg/μg of total protein and 5344.65 ± 1579.71 AFUs/μg of total protein. The serum levels of NO x in the patients with OSAS increased from 16.36 ± 5.78 to 25.94 ± 5.17 µM. Successful treatment for OSAS with nasal CPAP can restore blood levels of the SIRT1 protein and its activity and serum levels of NO x .

  19. Comparison of Effort of Breathing for Infants on Nasal Modes of Respiratory Support.

    PubMed

    Kamerkar, Asavari; Hotz, Justin; Morzov, Rica; Newth, Christopher J L; Ross, Patrick A; Khemani, Robinder G

    2017-06-01

    To directly compare effort of breathing between high flow nasal cannula (HFNC), nasal intermittent mechanical ventilation (NIMV), and nasal continuous positive airway pressure (NCPAP). This was a single center prospective cross-over study for patients <6 months in the cardiothoracic or pediatric intensive care unit receiving nasal noninvasive respiratory support after extubation. We measured effort of breathing using esophageal manometry with pressure-rate product (PRP) on all 3 modes. NIMV synchrony was determined by comparing patient efforts (esophageal manometry) with mechanically delivered breaths (spirometry in ventilator circuit). On NIMV, PRP and synchrony was also measured after adding a nasal clip on 26 patients. Forty-two children were included. Median (IQR) age was 2 (0.5, 4) months. There was no difference in median PRP between HFNC 6 liters per minute, 355 (270,550), NIMV 12/5 cm H2O, 341 (235, 472), and NCPAP 5 cm H2O, 340 (245,506) (P?=?.33). Results were similar regardless of HFNC flow rate or NIMV inspiratory pressure. Median PRP on CPAP of 5 cm H2O prior to extubation 255 (176, 375) was significantly lower than all postextubation values (P?nasal clip (P?>?.07)). However, as NIMV synchrony improved (>60%), PRP on NIMV was lower than on HFNC. For infants, effort of breathing is similar on HFNC, NIMV, and NCPAP after extubation, regardless of flow rate or inspiratory pressure. We speculate that bi-level NIMV may be superior if high levels of synchrony can be achieved. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Triclosan promotes Staphylococcus aureus nasal colonization.

    PubMed

    Syed, Adnan K; Ghosh, Sudeshna; Love, Nancy G; Boles, Blaise R

    2014-04-08

    The biocide triclosan is used in many personal care products, including toothpastes, soaps, clothing, and medical equipment. Consequently, it is present as a contaminant in the environment and has been detected in some human fluids, including serum, urine, and milk. Staphylococcus aureus is an opportunistic pathogen that colonizes the noses and throats of approximately 30% of the population. Colonization with S. aureus is known to be a risk factor for several types of infection. Here we demonstrate that triclosan is commonly found in the nasal secretions of healthy adults and the presence of triclosan trends positively with nasal colonization by S. aureus. We demonstrate that triclosan can promote the binding of S. aureus to host proteins such as collagen, fibronectin, and keratin, as well as inanimate surfaces such as plastic and glass. Lastly, triclosan-exposed rats are more susceptible to nasal colonization with S. aureus. These data reveal a novel factor that influences the ability of S. aureus to bind surfaces and alters S. aureus nasal colonization. IMPORTANCE Triclosan has been used as a biocide for over 40 years, but the broader effects that it has on the human microbiome have not been investigated. We demonstrate that triclosan is present in nasal secretions of a large portion of a test population and its presence correlates with Staphylococcus aureus nasal colonization. Triclosan also promotes the binding of S. aureus to human proteins and increases the susceptibility of rats to nasal colonization by S. aureus. These findings are significant because S. aureus colonization is a known risk factor for the development of several types of infections. Our data demonstrate the unintended consequences of unregulated triclosan use and contribute to the growing body of research demonstrating inadvertent effects of triclosan on the environment and human health.

  1. Prevalence of multidrug-resistant, coagulase-positive Staphylococcus aureus in nasal carriage, food, wastewater and paper currency in Jalandhar city (north-western), an Indian state of Punjab.

    PubMed

    Kumar, Harsh; Palaha, Rajdeep; Kaur, Navreet; Ratnakar, Wankhede Swapnil; Sodi, Aakanksha; Kaur, Manmeet; Katiyar, Richa; Sharma, Mamta; Kaur, Charanpreet; Kumar, Virendra

    2015-01-01

    Development of multidrug-resistant pattern in the bacterial community is a major threat to the society. Staphylococcus aureus is perhaps the pathogen of the greatest concern because of its inherent virulence, its ability to cause a diverse array of life-threatening situations and capacity to adapt to different environmental conditions. The aims of this study is to investigate the multidrug-resistant pattern of the coagulase-positive S. aureus isolated from nasal carriage, food, paper currency and wastewater samples. We had also studied the multiple antibiotic resistance index and in vitro production of β-lactamase. The study had found out 130 coagulase-positive S. aureus strains isolated from total of 595 samples such as anterior nares of preschool children (195), hospital nurses (100), drivers (76), food (86), wastewater (3) and paper currency (135) (Indian rupee). The biotypes pattern were as follows; A > D > B > C> UT. Multiple antibiotic resistance (MAR) value clearly defines the multidrug-resistant pattern of the S. aureus among different sources. Statistical analysis (one-way ANOVA) of results obtained indicated that the difference in the antibiotic resistance observed in the 130 bacterial isolates against the 23 different antibiotics used in this study was statically significant (p < 0.01).

  2. Mask versus Nasal Tube for Stabilization of Preterm Infants at Birth: Respiratory Function Measurements.

    PubMed

    van Vonderen, Jeroen J; Kamlin, C Omar; Dawson, Jennifer A; Walther, Frans J; Davis, Peter G; te Pas, Arjan B

    2015-07-01

    To compare the nasal tube with face mask as interfaces for stabilization of very preterm infants at birth by using physiological measurements of leak, obstruction, and expired tidal volumes during positive pressure ventilation (PPV). In the delivery room, 43 infants <30 weeks gestation were allocated to receive respiratory support by nasal tube or face mask. Respiratory function, heart rate, and oxygen saturation were measured. Occurrence of obstruction, amount of leak, and tidal volumes were compared using a Mann-Whitney U test or a Fisher exact test. The first 5 minutes after initiation of PPV were analyzed (1566 inflations in the nasal tube group and 1896 inflations in the face mask group). Spontaneous breathing coincided with PPV in 32% of nasal tube and 34% of face mask inflations. During inflations, higher leak was observed using nasal tube compared with face mask (98% [33%-100%] vs 14 [0%-39%]; P < .0001). Obstruction occurred more often (8.2% vs 1.1%; P < .0001). Expired tidal volumes were significantly lower during inflations when using nasal tube compared with face mask (0.0 [0.0-3.1] vs 9.9 [5.5-12.8] mL/kg; P < .0001) and when spontaneous breathing coincided with PPV (4.4 [2.1-8.4] vs 9.6 [5.4-15.2] mL/kg; P < .0001) but were similar during breathing on continuous positive airway pressure (4.7 [2.8-6.9] vs 4.8 [2.7-7.9] mL/kg; P > 0.05). Heart rate was not significantly different between groups, but oxygen saturation was significantly lower in the nasal tube group the first 2 minutes after start of respiratory support. The use of a nasal tube led to large leak, more obstruction, and inadequate tidal volumes compared with face mask. Trial registration Registered with the Dutch Trial Registry (NTR 2061) and the Australia and New Zealand Clinical Trials Register (ACTRN 12610000230055). Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Use of in vivo desensitization to treat a patient's claustrophobic response to nasal CPAP.

    PubMed

    Edinger, J D; Radtke, R A

    1993-10-01

    Continuous positive airway pressure (CPAP) has proven to be a safe, effective treatment for sleep apnea patients. However, many patients display claustrophobic reactions to the CPAP nasal mask and cannot tolerate this treatment. The current report describes the successful application of in vivo desensitization with a male apnea patient who initially failed CPAP therapy due to his claustrophobia. Over the course of treatment, the patient became able to tolerate using his CPAP device throughout his nocturnal sleep periods. Moreover, follow-up visits scheduled 6 months and again at 6 1/2 years after behavioral treatment showed that the patient continued to use CPAP on a regular basis. It is concluded that in vivo desensitization therapy may be useful in assisting claustrophobic patients to tolerate nasal CPAP. Results are discussed in view of the specific features of the case presented, and future applications of this behavioral procedure are encouraged.

  4. Nasal commensal Staphylococcus epidermidis counteracts influenza virus

    PubMed Central

    Chen, Hui-Wen; Liu, Pei-Feng; Liu, Yu-Tsueng; Kuo, Sherwin; Zhang, Xing-Quan; Schooley, Robert T.; Rohde, Holger; Gallo, Richard L.; Huang, Chun-Ming

    2016-01-01

    Several microbes, including Staphylococcus epidermidis (S. epidermidis), a Gram-positive bacterium, live inside the human nasal cavity as commensals. The role of these nasal commensals in host innate immunity is largely unknown, although bacterial interference in the nasal microbiome may promote ecological competition between commensal bacteria and pathogenic species. We demonstrate here that S. epidermidis culture supernatants significantly suppressed the infectivity of various influenza viruses. Using high-performance liquid chromatography together with mass spectrometry, we identified a giant extracellular matrix-binding protein (Embp) as the major component involved in the anti-influenza effect of S. epidermidis. This anti-influenza activity was abrogated when Embp was mutated, confirming that Embp is essential for S. epidermidis activity against viral infection. We also showed that both S. epidermidis bacterial particles and Embp can directly bind to influenza virus. Furthermore, the injection of a recombinant Embp fragment containing a fibronectin-binding domain into embryonated eggs increased the survival rate of virus-infected chicken embryos. For an in vivo challenge study, prior Embp intranasal inoculation in chickens suppressed the viral titres and induced the expression of antiviral cytokines in the nasal tissues. These results suggest that S. epidermidis in the nasal cavity may serve as a defence mechanism against influenza virus infection. PMID:27306590

  5. Nasal commensal Staphylococcus epidermidis counteracts influenza virus.

    PubMed

    Chen, Hui-Wen; Liu, Pei-Feng; Liu, Yu-Tsueng; Kuo, Sherwin; Zhang, Xing-Quan; Schooley, Robert T; Rohde, Holger; Gallo, Richard L; Huang, Chun-Ming

    2016-06-16

    Several microbes, including Staphylococcus epidermidis (S. epidermidis), a Gram-positive bacterium, live inside the human nasal cavity as commensals. The role of these nasal commensals in host innate immunity is largely unknown, although bacterial interference in the nasal microbiome may promote ecological competition between commensal bacteria and pathogenic species. We demonstrate here that S. epidermidis culture supernatants significantly suppressed the infectivity of various influenza viruses. Using high-performance liquid chromatography together with mass spectrometry, we identified a giant extracellular matrix-binding protein (Embp) as the major component involved in the anti-influenza effect of S. epidermidis. This anti-influenza activity was abrogated when Embp was mutated, confirming that Embp is essential for S. epidermidis activity against viral infection. We also showed that both S. epidermidis bacterial particles and Embp can directly bind to influenza virus. Furthermore, the injection of a recombinant Embp fragment containing a fibronectin-binding domain into embryonated eggs increased the survival rate of virus-infected chicken embryos. For an in vivo challenge study, prior Embp intranasal inoculation in chickens suppressed the viral titres and induced the expression of antiviral cytokines in the nasal tissues. These results suggest that S. epidermidis in the nasal cavity may serve as a defence mechanism against influenza virus infection.

  6. Infarcted angiomatous nasal polyps.

    PubMed

    Sheahan, Patrick; Crotty, Paul L; Hamilton, Sam; Colreavy, Michael; McShane, Donald

    2005-03-01

    Angiomatous nasal polyps are a rarely reported subtype of inflammatory sinonasal polyps that are characterized by extensive vascular proliferation and ectasia. Compromise of their vascular supply may occasionally lead to infarction, resulting in clinical, radiological and pathological features that simulate a neoplastic process. In the present paper, the salient characteristics of this unusual entity are described. The clinical, radiological and pathological features of two patients with infarcted angiomatous nasal polyps are presented. Grossly, the polyps had an unusual inhomogenous appearance and texture and were associated with a foul odor. CT findings included bony expansion and destruction. MRI findings included markedly inhomogenous contrast enhancement on T1-weighted images. Histopathologically, both cases showed abundant vascular ectasia, with widespread intraluminal thrombosis and necrosis. Recanalization and reparative changes were also present. Angiomatous nasal polyps are poorly documented in the literature. Although entirely benign, they may simulate neoplastic processes, thus awareness of their existence is of considerable importance.

  7. Nasal spray flu vaccine (image)

    MedlinePlus

    The flu vaccine can also be administered as a nasal spray instead of the usual injection method. It can be ... the recombinant influenza vaccine (RIV). The nasal spray flu vaccine (live attenuated influenza vaccine or LAIV) should not ...

  8. Positive Affect Relevant to Epistemic Curiosity to Reflect Continuance Intention to Join a Hands-On Making Contest

    ERIC Educational Resources Information Center

    Hong, Jon-Chao; Hwang, Ming-Yueh; Szeto, Elson; Tai, Kai-Hsin; Tsai, Chi-Ruei

    2016-01-01

    Hands-on making (e.g., "Maker") has become prevalent in current educational settings. To understand the role that students' epistemic curiosity plays in hands-on making contests, this study explored its correlation to students' positive affect and continuance intention to participate in a hands-on making contest called…

  9. Positive Affect Relevant to Epistemic Curiosity to Reflect Continuance Intention to Join a Hands-On Making Contest

    ERIC Educational Resources Information Center

    Hong, Jon-Chao; Hwang, Ming-Yueh; Szeto, Elson; Tai, Kai-Hsin; Tsai, Chi-Ruei

    2016-01-01

    Hands-on making (e.g., "Maker") has become prevalent in current educational settings. To understand the role that students' epistemic curiosity plays in hands-on making contests, this study explored its correlation to students' positive affect and continuance intention to participate in a hands-on making contest called…

  10. A quasi-positive family of continuous Darcy-flux finite-volume schemes with full pressure support

    NASA Astrophysics Data System (ADS)

    Edwards, Michael G.; Zheng, Hongwen

    2008-11-01

    A new family of flux-continuous, locally conservative, finite-volume schemes is presented for solving the general tensor pressure equation of subsurface flow in porous media. The new schemes have full pressure continuity imposed across control-volume faces. Previous families of flux-continuous schemes are point-wise continuous in pressure and flux. When applying the earlier point-wise flux-continuous schemes to strongly anisotropic full-tensor fields their failure to satisfy a maximum principle (as with other FEM and finite-volume methods) can result in loss of local stability for high anisotropy ratios which can cause strong spurious oscillations in the numerical pressure solution. An M-matrix analysis reveals the upper limits for guaranteeing a maximum principle for general 9-point schemes and aids in the design of schemes that minimize the occurrence of spurious oscillations in the discrete pressure field. The full pressure continuity schemes are shown to possess a larger range of flux-continuous schemes, than the previous point-wise counter parts. For strongly anisotropic full-tensor cases it is shown that the full quadrature range possessed by the new schemes permits these schemes to exploit quadrature points (previously out of range) that are shown to minimize spurious oscillations in discrete pressure solutions. The new formulation leads to a more robust quasi-positive family of flux-continuous schemes applicable to general discontinuous full-tensor fields.

  11. Nasalance in Cochlear Implantees

    PubMed Central

    Sreedevi, N; Lepcha, Anjali; Mathew, John

    2015-01-01

    Objectives Speech intelligibility is severely affected in children with congenital profound hearing loss. Hypernasality is a problem commonly encountered in their speech. Auditory information received from cochlear implants is expected to be far superior to that from hearing aids. Our study aimed at comparing the percentages of nasality in the speech of the cochlear implantees with hearing aid users and also with children with normal hearing. Methods Three groups of subjects took part in the study. Groups I and II comprised 12 children each, in the age range of 4-10 years, with prelingual bilateral profound hearing loss, using multichannel cochlear implants and digital hearing aids respectively. Both groups had received at least one year of speech therapy intervention since cochlear implant surgery and hearing aid fitting respectively. The third group consisted of age-matched and sex-matched children with normal hearing. The subjects were asked to say a sentence which consisted of only oral sounds and no nasal sounds ("Buy baby a bib"). The nasalance score as a percentage was calculated. Results Statistical analysis revealed that the children using hearing aids showed a high percentage of nasalance in their speech. The cochlear implantees showed a lower percentage of nasalance compared to children using hearing aids, but did not match with their normal hearing peers. Conclusion The quality of speech of the cochlear implantees was superior to that of the hearing aid users, but did not match with the normal controls. The study suggests that acoustic variables still exist after cochlear implantation in children, with hearing impairments at deviant levels, which needs attention. Further research needs to be carried out to explore the effect of the age at implantation as a variable in reducing nasality in the speech and attaining normative values in cochlear implantees, and also between unilateral versus bilateral implantees. PMID:26330912

  12. Transepithelial electrophysiological parameters in rabbit respiratory nasal mucosa isolated in vitro.

    PubMed

    Cremaschi, D; Rossetti, C; Draghetti, M T; Manzoni, C; Porta, C; Aliverti, V

    1991-01-01

    1. Transepithelial electrical p.d. (Vms), short circuit current (Isc) and transepithelial resistance (Rep) were determined in rabbit nasal mucosa and were compared with the equivalent parameters of human nasal mucosa. 2. Vms was about 1 mV (submucosa positive) in the absence of glucose, but increased continuously in the presence of glucose. Since Isc also increased in parallel and Rep remained constant (about 40 omega cm2), glucose effect was to power pumping. 3. Diffusion potentials raised by reducing luminal Cl- or Na+ or Cl- and Na+ concentrations were also measured and compared with values obtained in trachea and gallbladder. 4. Evidence is produced, with sounder basis than in trachea, that junctional pathways in airway epithelia are lined with fixed positive charges (which make anions more permeable than cations), unlike junctional pathways of the gastrointestinal tract which are lined with fixed negative charges.

  13. Nasal reconstruction after epithelioma.

    PubMed

    Rodríguez-Camps, S

    2001-01-01

    In this paper we present our procedure for the treatment, histopathological diagnosis, and resection of skin cancer in the nasal pyramid and its subsequent reconstruction. Because we are dealing with the most important anatomical feature of the face our goal is an aesthetic reconstruction [2,4] according to the anatomical subunits criterion of Burget [3]. First, a histopathological diagnosis is made to determine the nature of the tumor. Then, we proceed with the resection according to the Mohs Micrographic Surgery [1,5,7]. Then we begin with the first step of the nasal reconstruction.

  14. Large rhinolith causing nasal obstruction

    PubMed Central

    Dincer Kose, Onur; Kose, Taha Emre; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2015-01-01

    Rhinoliths are calcified masses located in the nasal cavity and may cause symptoms such as nasal obstruction, fetid odour and facial pain. They are usually diagnosed incidentally on radiographic examinations or depending on the symptoms. In this paper we report a 27-year-old Caucasian woman with a calcified mass in the right nasal cavity causing nasal obstruction, anosmia and facial pain. The calcified mass was removed by endonasal approach. PMID:25759270

  15. Geoscience Australia Continuous Global Positioning System (CGPS) Station Field Campaign Report

    SciTech Connect

    Ruddick, R.; Twilley, B.

    2016-03-01

    This station formed part of the Australian Regional GPS Network (ARGN) and South Pacific Regional GPS Network (SPRGN), which is a network of continuous GPS stations operating within Australia and its Territories (including Antarctica) and the Pacific. These networks support a number of different science applications including maintenance of the Geospatial Reference Frame, both national and international, continental and tectonic plate motions, sea level rise, and global warming.

  16. Control system to reduce the effects of friction in drive trains of continuous-path-positioning systems. [Patent application

    DOEpatents

    Green, W.L.

    1980-12-01

    An improved continuous-path-positioning servo-control system is provided for reducing the effects of friction arising at very low cutting speeds in the drive trains of numerically controlled cutting machines, and the like. The improvement comprises a feed forward network for altering the gain of the servo-control loop at low positioning velocities to prevent stick-slip movement of the cutting tool holder being positioned by the control system. The feed forward network shunts conventional lag-compensators in the control loop, or loops, so that the error signal used for positioning varies linearly when the value is small, but being limited for larger values. Thus, at higher positioning speeds there is little effect of the added component upon the control being achieved.

  17. Nasalance Norms in Greek Adults

    ERIC Educational Resources Information Center

    Okalidou, Areti; Karathanasi, Asimina; Grigoraki, Eleni

    2011-01-01

    The purposes of this study were to derive nasalance norms for monolingual Greek speakers, to examine nasalance scores as a function of gender and to draw cross-linguistic comparisons based on normative data. Participants read aloud a corpus of linguistic material, consisting of (1) a nasal text, an oral text and a balanced text; (2) a set of nasal…

  18. Nasalance Norms in Greek Adults

    ERIC Educational Resources Information Center

    Okalidou, Areti; Karathanasi, Asimina; Grigoraki, Eleni

    2011-01-01

    The purposes of this study were to derive nasalance norms for monolingual Greek speakers, to examine nasalance scores as a function of gender and to draw cross-linguistic comparisons based on normative data. Participants read aloud a corpus of linguistic material, consisting of (1) a nasal text, an oral text and a balanced text; (2) a set of nasal…

  19. Lysosomal exoglycosidases in nasal polyps.

    PubMed

    Chojnowska, Sylwia; Minarowska, Alina; Knaś, Małgorzata; Niemcunowicz-Janica, Anna; Kołodziejczyk, Paweł; Zalewska-Szajda, Beata; Kępka, Alina; Minarowski, Łukasz; Waszkiewicz, Napoleon; Zwierz, Krzysztof; Szajda, Sławomir Dariusz

    2013-01-01

    Nasal polyps are smooth outgrowths assuming a shape of grapes, formed from the nasal mucosa, limiting air flow by projecting into a lumen of a nasal cavity. Up to now the surgical resection is the best method of their treatment, but etiology and pathogenesis of the nasal polyps is not yet fully established. The aim of the study was the assessment of the selected lysosomal exoglycosidases activity in the nasal polyps. In this study the activity of β-galactosidase, α-mannosidase and α-fucosidase was determined in the tissue of the nasal polyps obtained from 40 patients (10F, 30M) and control tissues derived from mucosa of lower nasal conchas obtained during mucotomy from 20 patients (10F, 10M). We observed significant lower values of GAL, FUC and tendency to decrease of MAN and GLU concentration in nasal polyps (P) in comparison to control healthy nasal mucosa (C). In nasal polyp tissue (P) no differences of GAL, MAN and FUC specific activity in comparison to control mucosa (C) were found. Our research supports bioelectrical theory of the nasal polyps pathogenesis and directs attention at research on glycoconjugates and glycosidases of the nasal mucosa extracellular matrix. Copyright © 2013 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  20. Cosmetic and Functional Nasal Deformities

    MedlinePlus

    ... nasal complaints. Nasal deformity can be categorized as “cosmetic” or “functional.” Cosmetic deformity of the nose results in a less ... taste , nose bleeds and/or recurrent sinusitis . A cosmetic or functional nasal deformity may occur secondary to ...

  1. Nasal obstruction and human communication.

    PubMed

    Malinoff, R; Moreno, C

    1989-04-01

    Nasal obstruction may cause a variety of communication disorders, particularly in children. The effects of nasal obstruction on hearing, speech, language, and voice are examined. Methods for assessing the effects of nasal obstruction are delineated, and recommendations for therapeutic interventions are described.

  2. Recodifications of Academic Positions and Reiterations of Desire: Change but Continuity in Gendered Subjectivities

    ERIC Educational Resources Information Center

    Lapping, Claudia

    2006-01-01

    This article argues that the analysis of changes in the social position of women needs to distinguish between levels of social practice and psychic subjectification. The argument draws on Lacan's conception of the relationship between subjectivity, desire and sexual difference to describe gendered aspects of subjectivity embedded within the…

  3. Rural Special Education Teachers' Plans to Continue or Leave Their Teaching Positions.

    ERIC Educational Resources Information Center

    Westling, David L.; Whitten, Thomas M.

    1996-01-01

    A survey of 158 rural special education teachers found that 57% expected to be in the same position in 5 years. A predictive model developed through logistic regression analysis suggested that administrative support and job requirements played important roles in teachers' five-year plans. (Author/DB)

  4. The Effect of the Treatment with Heated Humidified High-Flow Nasal Cannula on Neonatal Respiratory Distress Syndrome in China: A Single-Center Experience

    PubMed Central

    Zheng, Ge; Huang, Xiao-qiu; Zhao, Hui-hui; Jin, Guo-Xing

    2017-01-01

    Background. Noninvasive respiratory support is considered the optimal method of providing assistance to preterm babies with breathing problems, including nasal continuous positive airway pressure (NCPAP) and humidified high flow nasal cannula (HHHFNC). The evidence of the efficacy and safety of HHHFNC used as the primary respiratory support for respiratory distress syndrome (RDS) is insufficient in low- and middle-income countries. Objective. To investigate the effect of heated humidified high flow nasal cannula on neonatal respiratory distress syndrome compared with nasal continuous positive airway pressure. Methods. An observational cross-sectional study was performed at a tertiary neonatal intensive care unit in suburban Wenzhou, China, in the period between January 2014 and December 2015. Results. A total of 128 infants were enrolled in the study: 65 in the HHHFNC group and 63 in the NCPAP group. The respiratory support with HHHFNC was similar to that with NCPAP with regard to the primary outcome. There is no significant difference between two groups in secondary outcomes. Comparing with NCPAP group, the incidence of nasal damage was lower in HHHFNC group. Conclusions. HHHFNC is an effective and well-tolerated strategy as the primary treatment of mild to moderate RDS in preterm infants older than 28 weeks of GA. PMID:28167860

  5. New maneuver for fixation of pediatric nasal bone fracture.

    PubMed

    Aldelaimi, Tahrir N

    2011-07-01

    Surgical treatment of nasal bone fractures in children is a complex and challenging task not only to maxillofacial surgeons but exceeding to ears, nose, and throat and plastic surgeons. Twelve child patients including 9 boys (75%) and 3 girls (25%) with nasal bone fractures were seen at the Maxillofacial Surgery Department at Ramadi Teaching Hospital during the period of December 2009 to December 2010. Fractured nasal bone is reduced to its anatomic position with Walsham forceps, and the dislocated or disrupted nasal septum with Asch forceps. The most common cause of the injury was road traffic accident and motorcycle accident 5 (42%); nasal deviation was found in 9 cases (75%), and depression in 2 (17%). In 9 patients (75%), injuries were isolated, and 3 (25%) were associated with other facial bone fractures. Significant advances have been made in the management of these injuries, decreasing the incidence of secondary deformities.

  6. Comparison of nasal acceleration and nasalance across vowels.

    PubMed

    Thorp, Elias B; Virnik, Boris T; Stepp, Cara E

    2013-10-01

    The purpose of this study was to determine the performance of normalized nasal acceleration (NNA) relative to nasalance as estimates of nasalized versus nonnasalized vowel and sentence productions. Participants were 18 healthy speakers of American English. NNA was measured using a custom sensor, and nasalance was measured using the KayPentax Nasometer II. Speech stimuli consisted of CVC syllables with the vowels (//, /æ/, /i/, /u/) and sentences loaded with high front, high back, low front, and low back vowels in both nasal and nonnasal contexts. NNA showed a small but significant effect of the vowel produced during syllable stimuli but no significant effect of vowel loading during sentence stimuli. Nasalance was significantly affected by the vowel being produced during both syllables and sentences with large effect sizes. Both NNA and nasalance were highly sensitive and specific to nasalization. NNA was less affected by vowel than nasalance. Discrimination of nasal versus nonnasal stimuli using NNA and nasalance was comparable, suggesting potential for use of NNA for biofeedback applications. Future work to improve calibration of NNA is needed to lower intersubject variability.

  7. Is a Bioprosthetic Valve in the Aortic Position Desirable with a Continuous Flow LVAD?

    PubMed

    Doi, Atsuo; Marasco, Silvana F; McGiffin, David C

    2015-05-01

    Commissural fusion of the native aortic valve in a patient with a continuous flow left ventricular assist device (LVAD) is a known phenomenon. This may result in aortic insufficiency (AI) leading to symptomatic heart failure. In patients with AI at the time of LVAD implantation, repairing, or replacing the aortic valve is advisable. We describe a patient who had a severe dilated cardiomyopathy and moderate AI who underwent implantation of an LVAD and aortic valve replacement with a bioprosthesis that subsequently developed commissural fusion which was found at the time of heart transplantation. This case highlights the conundrum of the management of AI in patients requiring LVAD support.

  8. Measuring and Characterizing the Human Nasal Cycle

    PubMed Central

    Kahana-Zweig, Roni; Geva-Sagiv, Maya; Weissbrod, Aharon; Secundo, Lavi; Soroker, Nachum; Sobel, Noam

    2016-01-01

    Nasal airflow is greater in one nostril than in the other because of transient asymmetric nasal passage obstruction by erectile tissue. The extent of obstruction alternates across nostrils with periodicity referred to as the nasal cycle. The nasal cycle is related to autonomic arousal and is indicative of asymmetry in brain function. Moreover, alterations in nasal cycle periodicity have been linked to various diseases. There is therefore need for a tool allowing continuous accurate measurement and recording of airflow in each nostril separately. Here we provide detailed instructions for constructing such a tool at minimal cost and effort. We demonstrate application of the tool in 33 right-handed healthy subjects, and derive several statistical measures for nasal cycle characterization. Using these measures applied to 24-hour recordings we observed that: 1: subjects spent slightly longer in left over right nostril dominance (left = 2.63 ± 0.89 hours, right = 2.17 ± 0.89 hours, t(32) = 2.07, p < 0.05), 2: cycle duration was shorter in wake than in sleep (wake = 2.02 ± 1.7 hours, sleep = 4.5 ± 1.7 hours, (t(30) = 5.73, p < 0.0001). 3: slower breathing was associated with a more powerful cycle (the extent of difference across nostrils) (r = 0.4, p < 0.0001), and 4: the cycle was influenced by body posture such that lying on one side was associated with greater flow in the contralateral nostril (p < 0.002). Finally, we provide evidence for an airflow cycle in each nostril alone. These results provide characterization of an easily obtained measure that may have diagnostic implications for neurological disease and cognitive state. PMID:27711189

  9. Measuring and Characterizing the Human Nasal Cycle.

    PubMed

    Kahana-Zweig, Roni; Geva-Sagiv, Maya; Weissbrod, Aharon; Secundo, Lavi; Soroker, Nachum; Sobel, Noam

    2016-01-01

    Nasal airflow is greater in one nostril than in the other because of transient asymmetric nasal passage obstruction by erectile tissue. The extent of obstruction alternates across nostrils with periodicity referred to as the nasal cycle. The nasal cycle is related to autonomic arousal and is indicative of asymmetry in brain function. Moreover, alterations in nasal cycle periodicity have been linked to various diseases. There is therefore need for a tool allowing continuous accurate measurement and recording of airflow in each nostril separately. Here we provide detailed instructions for constructing such a tool at minimal cost and effort. We demonstrate application of the tool in 33 right-handed healthy subjects, and derive several statistical measures for nasal cycle characterization. Using these measures applied to 24-hour recordings we observed that: 1: subjects spent slightly longer in left over right nostril dominance (left = 2.63 ± 0.89 hours, right = 2.17 ± 0.89 hours, t(32) = 2.07, p < 0.05), 2: cycle duration was shorter in wake than in sleep (wake = 2.02 ± 1.7 hours, sleep = 4.5 ± 1.7 hours, (t(30) = 5.73, p < 0.0001). 3: slower breathing was associated with a more powerful cycle (the extent of difference across nostrils) (r = 0.4, p < 0.0001), and 4: the cycle was influenced by body posture such that lying on one side was associated with greater flow in the contralateral nostril (p < 0.002). Finally, we provide evidence for an airflow cycle in each nostril alone. These results provide characterization of an easily obtained measure that may have diagnostic implications for neurological disease and cognitive state.

  10. A prospective 8 week trial of nasal interfaces vs. a novel oral interface (Oracle) for treatment of obstructive sleep apnea hypopnea syndrome.

    PubMed

    Khanna, Ritu; Kline, Lewis R

    2003-07-01

    To compare efficacy, compliance rates, and side effects of a new strapless oral interface, the Oracle, with available nasal masks over 8 weeks of use for the treatment of obstructive sleep apnea hypopnea syndrome (OSAHS). A total of 38 patients with OSAHS (respiratory disturbance index (RDI) >/=15/h) were enrolled after the diagnostic polysomnogram for subsequent continuous positive airway pressure (CPAP) therapy. After randomization, therapeutic pressures during a titration study were determined for 21 patients in the oral group and 17 patients in the nasal group. Comparisons for nasal and oral interfaces were made for baseline patient characteristics, average hours of CPAP use, side effects from therapy, and among questionnaires evaluating patients' subjective responses to therapy at months 1 and 2. No significant difference was observed in the average hours of CPAP use between the oral (4.5+/-2.1; 5.5+/-2.6) and nasal groups (4.0+/-2.6; 4.8+/-2.5) for either month 1 or 2 (P>0.05). The dropout rates were similar for both groups after 8 weeks of therapy. However, patients in the nasal group had higher occurrences of side effects such as nasal congestion, dryness, and air leaks, whereas patients in the oral group experienced more oral dryness and gum pain. Oral delivery of CPAP with the Oracle is an effective and suitable alternative for patients with OSAHS.

  11. Continuous Attractor Network Model for Conjunctive Position-by-Velocity Tuning of Grid Cells

    PubMed Central

    Si, Bailu; Romani, Sandro; Tsodyks, Misha

    2014-01-01

    The spatial responses of many of the cells recorded in layer II of rodent medial entorhinal cortex (MEC) show a triangular grid pattern, which appears to provide an accurate population code for animal spatial position. In layer III, V and VI of the rat MEC, grid cells are also selective to head-direction and are modulated by the speed of the animal. Several putative mechanisms of grid-like maps were proposed, including attractor network dynamics, interactions with theta oscillations or single-unit mechanisms such as firing rate adaptation. In this paper, we present a new attractor network model that accounts for the conjunctive position-by-velocity selectivity of grid cells. Our network model is able to perform robust path integration even when the recurrent connections are subject to random perturbations. PMID:24743341

  12. Effects of nasal drug delivery device and its orientation on sprayed particle deposition in a realistic human nasal cavity.

    PubMed

    Tong, Xuwen; Dong, Jingliang; Shang, Yidan; Inthavong, Kiao; Tu, Jiyuan

    2016-10-01

    In this study, the effects of nasal drug delivery device and the spray nozzle orientation on sprayed droplets deposition in a realistic human nasal cavity were numerically studied. Prior to performing the numerical investigation, an in-house designed automated actuation system representing mean adults actuation force was developed to produce realistic spray plume. Then, the spray plume development was filmed by high speed photography system, and spray characteristics such as spray cone angle, break-up length, and average droplet velocity were obtained through off-line image analysis. Continuing studies utilizing those experimental data as boundary conditions were applied in the following numerical spray simulations using a commercially available nasal spray device, which was inserted into a realistic adult nasal passage with external facial features. Through varying the particle releasing direction, the deposition fractions of selected particle sizes on the main nasal passage for targeted drug delivery were compared. The results demonstrated that the middle spray direction showed superior spray efficiency compared with upper or lower directions, and the 10µm agents were the most suitable particle size as the majority of sprayed agents can be delivered to the targeted area, the main passage. This study elaborates a comprehensive approach to better understand nasal spray mechanism and evaluate its performance for existing nasal delivery practices. Results of this study can assist the pharmaceutical industry to improve the current design of nasal drug delivery device and ultimately benefit more patients through optimized medications delivery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Effect of continuing repeated passive and active exercises on knee's position senses in patients with hemiplegia.

    PubMed

    Kwon, Oh Sung; Lee, Seung Won

    2013-01-01

    To determine the repeated passive movement (RPM) and repeated active movement (RAM) exercise on position sense of the knee joint in patients with hemiplegia. 45 hemiplegia patients were randomly allocated to either the control group(no exercise), RPM group, or RAM group, with 15 subjects in each group. The exercise was repeated 60 times on the angle 10 to 100 degrees of the knee joint with an angle speed of 120°/s, with three sets for 15 minutes. Evaluation was performed using Passive Angle Repositioning (PAR) and Active Angle Repositioning (AAR). Error of positioning sense showed a decrease in PAR and AAR in the RPM group (p < 0.01) and an increase in AAR was observed in the RAM group (p < 0.05). In comparison of knee joint position sense error value and rate of change among the three groups, the RPM group is decreased mostly in PAR and AAR (p < 0.01), and Error value (p < 0.05) and rate of change (p < 0.01) of the RAM group showed a greater increase in AAR than the control group. RAM exercise can support an increase in proprioception on the knee joint of hemiplegia; however, RAM exercise that causes fatigue can decrease proprioception.

  14. Continuous wavelength tunable laser source with optimum positioning of pivot axis for grating

    DOEpatents

    Pushkarsky, Michael; Amone, David F.

    2010-06-08

    A laser source (10) for generating a continuously wavelength tunable light (12) includes a gain media (16), an optical output coupler (36F), a cavity collimator (38A), a diffraction grating (30), a grating beam (54), and a beam attacher (56). The diffraction grating (30) is spaced apart from the cavity collimator (38A) and the grating (30) cooperates with the optical output coupler (36F) to define an external cavity (32). The grating (30) includes a grating face surface (42A) that is in a grating plane (42B). The beam attacher (56) retains the grating beam (54) and allows the grating beam (54) and the grating (30) to effectively pivot about a pivot axis (33) that is located approximately at an intersection of a pivot plane (50) and the grating plane (42B). As provided herein, the diffraction grating (30) can be pivoted about the unique pivot axis (33) to move the diffraction grating (30) relative to the gain media (16) to continuously tune the lasing frequency of the external cavity (32) and the wavelength of the output light (12) so that the output light (12) is mode hop free.

  15. Azelastine Nasal Spray

    MedlinePlus

    ... and replace with the pump unit. Prime the delivery system (pump unit) with four sprays or until a fine mist appears. If 3 days or more have elapsed since your last use of the nasal spray, reprime the pump with two sprays or until a fine mist appears.

  16. Management of nasal hemangiomas.

    PubMed

    Hochman, Marcelo; Mascareno, Alfredo

    2005-01-01

    Infantile hemangiomas commonly involve the nose. Because of the nose's prominence as an aesthetically and functionally sensitive area, management of these lesions has important implications. The available options including medical therapy, lasers, and surgery are reviewed with recommendations specific to nasal tip and lobule lesions based on the senior author's (M.H.) experience.

  17. Oxymetazoline Nasal Spray

    MedlinePlus

    ... Rinse the tip of the dispenser with hot water or wipe it clean after you use it.Follow the directions for using the nasal spray that appear on the package label. If you are using a product that comes in a pump dispenser, press down on the rim several times ...

  18. Cromolyn Sodium Nasal Solution

    MedlinePlus

    Cromolyn comes as a solution to use with a special nasal applicator. It usually is inhaled three to six times a day to prevent allergy ... first time, read the instructions provided with the solution. Ask your doctor, pharmacist, or respiratory therapist to ...

  19. Positive appraisal of in-home family caregivers of dementia patients as an influence on the continuation of caregiving.

    PubMed

    Kajiwara, Kohei; Nakatani, Hisae; Ono, Mitsu; Miyakoshi, Yukiko

    2015-03-01

    We attempted to determine the factors that influence the continuation of in-home caregiving for patients with dementia. The participants were family caregivers of dementia patients who received home care services. Data were collected via a questionnaire completed by caregivers and then returned in the mail. Of the 705 caregivers who received the questionnaire, 405 completed and returned it (response rate: 57.4%). The average age of the caregivers was 63.9 ± 11.5 years, and they had been providing care for an average of 5.1 ± 4.1 years. The average age of the patients was 84.7 ± 7.4 years. We analyzed the path model. Caregivers' current feelings about continuing caregiving were directly affected by a positive appraisal of caregiving (β = 0.20, P < 0.001) and by the burden they experienced (β = -0.39, P < 0.001). The continuation of caregiving of patients with worsening symptoms was directly affected by a positive appraisal of caregiving (β = 0.15, P < 0.01) and by the burden experienced by the caregivers (β = -0.46, P < 0.001). The continuation of caregiving was indirectly affected by the patients' cognitive impairment and by the behavioral and psychological symptoms of dementia score. The continuation of in-home caregiving among caregivers of patients with dementia was affected by both positive appraisal and caregiver burden. In addition, the present study revealed that behavioral and psychological symptoms of dementia score indirectly affects the continuation of caregiving by directly affecting caregiver burden. © 2014 The Authors. Psychogeriatrics © 2014 Japanese Psychogeriatric Society.

  20. [Clinical application of the forced oscillation technique for titration of pressure support levels in chronic obstructive pulmonary disease patients during nasal noninvasive positive pressure ventilation].

    PubMed

    Wang, Hua; Chen, Rong-Chang; He, Sheng; Luo, Qun

    2009-01-01

    To study the use of oscillatory resistance (Rrs) and reactance (Xrs) to guide the settings of pressure level of ventilators in patients with severe chronic obstructive pulmonary disease (COPD) during noninvasive positive pressure ventilation (NPPV). Five Hz oscillatory inspiratory Rrs (R(re, in)) at different NPPV pressure levels in 8 patients were calculated and compared to inspiratory pulmonary resistance (R(L, in)) measured by means of oesophageal manometry. The difference between inspiratory and expiratory Xrs (deltaXrs) at different CPAP levels were also measured for each breathing cycle, which were subsequently analyzed and classified as flow-limited (EFL) or non-EFL by means of Mead-Whittenberger method. Then, the relationship among CPAP levels, the percentage of EFL breathing cycles at different CPAP levels and deltaXrs were analyzed and the threshold value of deltaXrs with maximum sensitivity and specificity to detect EFL were calculated. The mean values of R(rs, in) and R(L, in) were (6.5 +/- 1.6) and (9 +/- 5) cm H2O x s(-1) x L(-1) (1 cm H2O = 0.098 kPa), respectively,r = 0.64, P < 0.01, but the agreement between these two resistances were poor and with a median of -2. 7 (-5.7 - 0.7)cm H2O x s(-1) x L(-1), and the limits of agreement ranged from -10.6 cm H2O x s(-1) x L(-1) to 4.9 cm H2O x s(-1) x L(-1). The linear regression equation of R(rs, in) to R(L, in) was R(L, in) = -1.62 + 1.69 R(rs, i), F = 109.6, P < 0.01. Increase in CPAP level resulted in decrease in deltaXrs and in numbers of EFL breathing cycles. The mean value of deltaXrs in EFL breathing cycles was significantly higher than that in NFL, and the threshold value of deltaXrs for detecting EFL was 1.83 cm H2O x s(-1) x L(-1), with a sensitivity of 94% and specificity of 97% respectively. Although slightly underestimated, R(rs, in) is helpful to guide the settings of inspiratory positive airway pressure level, which will appropriately overcome the elevated pulmonary resistance, and the

  1. Lgr5 regulates the regeneration of lesioned nasal respiratory epithelium.

    PubMed

    Zhang, Yan-Qiang; Li, Peng; Zhang, Feng-Qin; Sun, Shao-Jun; Cao, Yin-Guang

    2016-12-09

    Nasal respiratory epithelium is a ciliated pseudostratified columnar epithelium. The cellular components of nasal respiratory epithelium include ciliated cells, goblet cells, and basal cells. Until now, our knowledge in the development of nasal respiratory epithelium is still limited and the cellular mechanism of regeneration is still elusive. In this study, we found that adult stem cell marker leucine-rich repeat-containing G-protein coupled receptor 5 (Lgr5) is expressed in the mice nasal respiratory epithelium. Both immunostaining and lineage tracing analysis indicated Lgr5 positive cells in the nasal respiratory epithelium are proliferative stem/progenitor cells. Using the Rosa-Tdtomato and Rosa26-DTR mice, we elucidated that Lgr5(+) cells participate in the regeneration of lesioned nasal respiratory epithelium, and this group of cells is necessary in the process of epithelium recovery. Using the in vitro culture system, we observed the formation of spheres from Lgr5(+) cells and these spheres have the capacity to generate other types of cells. Above all, this study reported a group of previously unidentified progenitor/stem cells in nasal respiratory epithelium, unveiling the potential cellular mechanism in nasal respiratory epithelium regeneration.

  2. Correlation between Objective and Subjective Assessment of Nasal Patency

    PubMed Central

    Mozzanica, Francesco; Gera, Roberto; Bulgheroni, Chiara; Ambrogi, Federico; Schindler, Antonio; Ottaviani, Francesco

    2016-01-01

    Introduction: This study was performed to evaluate the correlation between the objective and subjective sensation of nasal patency, assessed through a validated questionnaire, the Italian version of the NOSE scale, and the rhinomanometric results in a large cohort of patients complaining about nasal obstruction. Materials and Methods: Data was obtained from a total of 233 adult patients, (123 males, 110 females, with a mean age of 43.7 years) with a diagnosis of septal deviation and complaining about nasal obstruction. Anterior active rhinomanometry was used for objective assessment, while the I-NOSE scale and a visual analog scale (VAS) were used for subjective evaluation. Results: Positive correlations between I-NOSE scores and VAS and rhinomanometric results were found. The higher correlation was demonstrated between the HUNR (higher unilateral nasal resistance) parameter of rhinomanometry and the second item of the I-NOSE scale (Nasal blockage or obstruction). No significant correlation was found between the fourth item of the I-NOSE (Trouble sleeping) and the VAS score. The VAS score appeared mildly, but still significantly, correlated with the HUNR parameter of rhinomanometry. Conclusion: The correlation between the subjective sensation of nasal patency and the rhinomanometric data proved to be significant. No correlation between subjective sensation of trouble sleeping and rhinomanometric assessment was found. In counselling with patients complaining of nasal obstruction trouble in sleeping should not be considered as a symptom related to nasal obstruction. PMID:27738607

  3. Cosmetic Concerns Related to the Posttraumatic Nose without Nasal Obstruction.

    PubMed

    Farrior, Edward H; Eisler, Lindsay S

    2015-06-01

    Because of its prominent position on the facial skeleton, the nose is commonly injured. Though significant trauma can result in nasal obstruction, there is also considerable concern for potential cosmetic deformity. Repairing traumatic deformities is complex and can involve all aspects of the nose, including the bony and cartilaginous framework as well as the soft tissue envelope. Trauma can result in deflection, asymmetry, and deformity of the bony nasal dorsum, midvault, and nasal tip. Any serious nasal trauma places patients at risk for complications that may include nasal septal hematoma, septal perforation, and possible cerebral spinal fluid leak. Unrecognized or untreated septal hematomas can result in cartilaginous septal necrosis followed by saddle nose deformity. Though damage to structural scaffolding is often the cause of cosmetic deformity following nasal trauma, the nasal soft tissue envelope is also commonly affected. This can result in lacerations, avulsions, and traumatic tattooing. The following will discuss the evaluation, diagnosis, and management of these cosmetic concerns relating to nasal trauma.

  4. Continuous vs. intermittent vancomycin therapy for Gram-positive infections not caused by methicillin-resistant Staphylococcus aureus.

    PubMed

    Duszynska, Wieslawa; Taccone, Fabio S; Hurkacz, Magdalena; Wiela-Hojenska, Anna; Kübler, Andrzej

    2016-03-01

    The aim of this study was to evaluate the effects of vancomycin pharmacokinetics (PKs) on effectiveness and safety in the treatment of Gram-positive infections due to pathogens other than methicillin-resistant Staphylococcus aureus (MRSA). Prospective study including septic patients received either continuous (N.=21) or intermittent (N.=21) infusions of vancomycin; the target drug concentration was 15-20 mg/L and target area under the curve of vancomycin concentrations over the minimum inhibitory concentration of the pathogen on day 1 (AUC24/MIC) >400. Clinical and microbiological responses, the development of acute kidney injury (AKI) and therapy costs were recorded. The median AUC24/MIC was 195(133-343) vs. 189(136-328) mg/L*h in the continuous and intermittent infusion groups. Target drug concentrations were achieved in 15/21 vs. 9/21 (P=0.12) patients and AUC24/MIC>400 in only 5/21 vs. 3/21 (P=0.35) patients of continuous and intermittent groups, respectively. High clinical cure (17/21 for continuous vs. 17/21 for intermittent, P=1.00) and microbiological eradication (17/21 vs. 15/21, P=0.47) were observed in both groups and not associated with drug concentrations or with AUC24/MIC. AKI was diagnosed during therapy in 5/21 patients in the continuous group and 8/21 in the intermittent group (P=0.32). The median total therapy costs were lower in the continuous than in the intermittent group (377 [304-485] vs. 552 [371-644] €, P=0.04). Vancomycin resulted in high clinical response during non-MRSA Gram-positive infections treatment even at drug concentrations lower than those for MRSA. A continuous infusion of vancomycin was associated with a significant reduction in therapy costs compared to intermittent infusions.

  5. Nasalance norms in Greek adults.

    PubMed

    Okalidou, Areti; Karathanasi, Asimina; Grigoraki, Eleni

    2011-08-01

    The purposes of this study were to derive nasalance norms for monolingual Greek speakers, to examine nasalance scores as a function of gender and to draw cross-linguistic comparisons based on normative data. Participants read aloud a corpus of linguistic material, consisting of (1) a nasal text, an oral text and a balanced text; (2) a set of nasal sentences and four sets of oral sentences and (3) repetitions of each of 12 syllable types (8 oral and 4 nasal). The last two sets of material corpus were based on an adaptation of the Simplified Nasometric Assessment Procedures Test (SNAP test) test ( MacKay and Kummer, 1994 ) in Greek, called the G-SNAP test. Eighty monolingual healthy young adult speakers of Greek, 40 males (mean age = 21 years) and 40 females (mean age = 20.5 years), with normal hearing and speech characteristics and unremarkable history were included in the study. The Nasometer (model 6200-3) was used to derive nasalance scores. Mean normative nasalance for spoken Greek was 25.50%, based on the G-oronasal text (with 8.6% nasals). Nasalance scores did not differ significantly with respect to gender. Finally, spoken Greek consistently yielded lower nasalance scores than other languages examined in past work. The aforementioned normative data on nasalance of young adult speakers of Greek are valid across gender and have direct clinical utility as they provide valuable reference information for the diagnosis and management of Greek adults with resonance disorders caused by velar dysfunction.

  6. Does rhinoplasty improve nasal breathing?

    PubMed

    Xavier, Rui

    2010-08-01

    Rhinoplasty is a surgical procedure that aims to improve nasal aesthetics and nasal breathing. The aesthetic improvement of the nose is usually judged subjectively by the patient and the surgeon, but the degree of improvement of nasal obstruction is difficult to assess by clinical examination only. The measurement of peak nasal inspiratory flow (PNIF) is a reliable tool that has been shown to correlate with other objective methods of assessing nasal breathing and with patients' symptoms of nasal obstruction. Twenty-three consecutive patients undergoing rhinoplasty have been evaluated by measurement of PNIF before and after surgery. All but three patients had an increase in PNIF after surgery. The mean preoperative PNIF was 86.5 L/min and the mean postoperative PNIF was 123.0 L/min ( P < 0.001). Not surprisingly, the greatest improvement in PNIF was achieved when bilateral spreader grafts were used. This study suggests that rhinoplasty does improve nasal breathing. (c) Thieme Medical Publishers

  7. Facilitation of accurate and effective radiation therapy using fentanyl pectin nasal spray (FPNS) to reduce incidental breakthrough pain due to procedure positioning.

    PubMed

    Prieto, Isabel; Pardo, José; Luna, Javier; Marin, Juan P; Olivera, Jesús; Garcia, Antonio J; Perez, Ana M

    2016-04-01

    To provide effective and accurate radiotherapy (RT) for advanced cancer patients who experience breakthrough pain (BP) due to positioning manoeuvres, through the use of FPNS. Secondary endpoints were the dose and time required to achieve a 50% numeric rating scale (NRS) reduction and conduction of a pharmacoeconomic analysis. Twenty-seven advanced cancer patients with moderate-severe BP associated with routine radiotherapy procedures and manoeuvres were selected to receive FPNS. Most patients (20/27) had bone metastases. The patients showed a low Karnovsky performance status (mean 54%; range: 30-80). BP intensity was scored with the NRS before and after the procedures that triggered it. All patients were already receiving opioid baseline treatment at a total dose equivalent to 40-160mg oral morphine. Before the procedure, BP was treated with 100-400μg of FPNS. Data related to tolerance, pain relief, onset of the relief and efficient dose to allow RT to proceed were collected. In 26 patients the BP score was reduced by at least 50% as determined in 15.5min (range 8-35min) after fentanyl pectin intranasal administration, and pain relief started after 7min (range 3-15min); p<0.05 in both cases. The duration of pain reduction facilitated the proceeding of RT. The Mean NRS score before the procedure was 9 (95%CI: 8.6-9.4) and decreased during procedure to 3 (95%CI: 2.5-3.8). The average dose of FPNS for most patients was 100-200μg to achieve pain control, except in three patients who required progressive doses of up to 300-400μg. After receiving 300μg, one patient dropped out of the study due to severe adverse effects (nausea). Seven patients reported minor undesirable effects related to FPNS administration. Certain necessary RT procedures in advanced cancer patients can cause severe BP episodes. A simple, safe, fast acting and strong analgesic is needed. FPNS is a rapidly absorbed opioid analgesic with a pain relief profile that would be particularly well suited

  8. Mask versus nasal tube for stabilization of preterm infants at birth: a randomized controlled trial.

    PubMed

    Kamlin, C Omar F; Schilleman, Kim; Dawson, Jennifer A; Lopriore, Enrico; Donath, Susan M; Schmölzer, Georg M; Walther, Frans J; Davis, Peter G; Te Pas, Arjan B

    2013-08-01

    Positive-pressure ventilation (PPV) using a manual ventilation device and a face mask is recommended for compromised newborn infants in the delivery room (DR). Mask ventilation is associated with airway obstruction and leak. A nasal tube is an alternative interface, but its safety and efficacy have not been tested in extremely preterm infants. An unblinded randomized controlled trial was conducted in Australia, and the Netherlands. Infants were stratified by gestational age (24-25/26-29 weeks) and center. Immediately before birth infants were randomly assigned to receive PPV and/or continuous positive airway pressure with either a nasal tube or a size 00 soft, round silicone mask. Resuscitation protocols were standardized; respiratory support was provided using a T-piece device commencing in room air. Criteria for intubation included need for cardiac compressions, apnea, continuous positive airway pressure >7 cm H2O, and fraction of inspired oxygen >0.4. Primary outcome was endotracheal intubation in the first 24 hours from birth. Three hundred sixty-three infants were randomly assigned; the study terminated early on the grounds of futility. Baseline variables were similar between groups. Intubation rates in the first 24 hours were 54% and 55% in the nasal tube and face mask groups, respectively (odds ratio: 0.97; 95% confidence interval: 0.63-1.50). There were no important differences in any of the secondary outcomes within the whole cohort or between the 2 gestational age subgroups. In infants at <30 weeks' gestation receiving PPV in the DR, there were no differences in short-term outcomes using the nasal tube compared with the face mask.

  9. Continuous lateral gradients in film morphology for position sensitive detection and organic solar cell optimization

    NASA Astrophysics Data System (ADS)

    Campoy-Quiles, M.; Randon, V.; Mróz, M. M.; Jarzaguet, M.; Garriga, M.; Cabanillas-González, J.

    2013-07-01

    We present a method to fabricate binary organic donor and acceptor blends exhibiting a controlled lateral gradient in morphology. Upon combining photometry, ellipsometry and Xray maps together with photoinduced absorption measurements, we show how the gradual exposure to solvent vapor results in a varying degree of polymer crystallinity for the polythiophene/soluble fullerene system along one direction. These morphologically graded samples are characterized by a spectral photoresponse that depends on the specific location in the area of the device where the light beam impinges, a property that stands as proof-of-concept for position sensitive detection. Moreover, we demonstrate that the development of graded morphologies is an effective one-step method which allows for fast performance optimization of organic solar cells. Finally, the appropriateness of eight different solvents for morphology control via vapor annealing is evaluated in a time-effective way using the advanced method, which helps to identify boiling point and solubility as the key processing parameters.

  10. [Post-traumatic aneurysm of the dorsal nasal artery. A rarity following blunt trauma].

    PubMed

    Schuldt, T

    2010-12-01

    We report the case of a 69-year-old male patient who appeared in our clinic with persistent swelling on the right middle nasal bridge of 3 months' standing following blunt trauma. On physical examination the swelling was pulsatile and a flow was identified on color Doppler sonography. MRT of the head demonstrated an aneurysm of the dorsal nasal artery. We treated the aneurysm in an open surgical procedure under local anaesthesia. Due to the superficial position of this artery, open injuries are common after blunt nasal trauma. Some cases of aneurysm of the temporal artery have been described. Aneurysm of the dorsal nasal artery is a rare result of nasal trauma.

  11. Position Statement on the management of continuous subcutaneous insulin infusion (CSII): The Italian Lazio experience.

    PubMed

    Maurizi, Anna R; Suraci, Concetta; Pitocco, Dario; Schiaffini, Riccardo; Tubili, Claudio; Morviducci, Lelio; Giordano, Renato; Manfrini, Silvia; Lauro, Davide; Frontoni, Simona; Pozzilli, Paolo; Buzzetti, Raffaella

    2016-01-01

    This document has been developed by a group of Italian diabetologists with extensive experience in continuous subcutaneous insulin infusion (CSII) therapy to provide indications for the clinical management of CSII in diabetic patients (both type 1 and type 2) based on delivery mode operating in Italy. Although the potential benefits of pump therapy in achieving glycemic goals is now accepted, such results cannot be obtained without specific knowledge and skills being conveyed to patients during ad hoc educational training. To ensure that these new technologies reach their full effectiveness, as demonstrated theoretically and clinically, a careful assessment of the overall therapeutic and educational process is required, in both qualitative and quantitative terms. Therefore, to ensure the cost-effectiveness of insulin pump therapy and to justify reimbursement of therapy costs by the National Health System in Italy, in this article we present a model for diabetes and healthcare centers to follow that provides for different levels of expertise in the field of CSII therapy. This model will guarantee the provision of excellent care during insulin pump therapies, thus representing the basis for a successful outcome and expansion of this form of insulin treatment in patients with diabetes while also keeping costs under control. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  12. Positioning.

    ERIC Educational Resources Information Center

    Conone, Ruth M.

    The key to positioning is the creation of a clear benefit image in the consumer's mind. One positioning strategy is creating in the prospect's mind a position that takes into consideration the company's or agency's strengths and weaknesses as well as those of its competitors. Another strategy is to gain entry into a position ladder owned by…

  13. Auto-titrating continuous positive airway pressure treatment for obstructive sleep apnoea after acute quadriplegia (COSAQ): study protocol for a randomized controlled trial.

    PubMed

    Berlowitz, David J; Ayas, Najib; Barnes, Maree; Brown, Douglas J; Cistulli, Peter A; Geraghty, Tim; Graham, Alison; Lee, Bonsan Bonne; Morris, Meg; O'Donoghue, Fergal; Rochford, Peter D; Ross, Jack; Singhal, Balraj; Spong, Jo; Wadsworth, Brooke; Pierce, Robert J

    2013-06-19

    Quadriplegia is a severe, catastrophic injury that predominantly affects people early in life, resulting in lifelong physical disability. Obstructive sleep apnoea is a direct consequence of quadriplegia and is associated with neurocognitive deficits, sleepiness and reduced quality of life. The usual treatment for sleep apnoea is nasal continuous positive airway pressure (CPAP); however, this is poorly tolerated in quadriplegia. To encourage patients to use this therapy, we have to demonstrate that the benefits outweigh the inconvenience. We therefore propose a prospective, multinational randomized controlled trial of three months of CPAP for obstructive sleep apnoea after acute quadriplegia. Specialist spinal cord injury centres across Australia, New Zealand, the UK and Canada will recruit medically stable individuals who have sustained a (new) traumatic quadriplegia (complete or incomplete second cervical to first thoracic level lesions). Participants will be screened for obstructive sleep apnoea using full, portable sleep studies. Those with an apnoea hypopnoea index greater than 10 per hour will proceed to an initial three-night trial of CPAP. Those who can tolerate CPAP for at least 4 hours on at least one night of the initial trial will be randomized to either usual care or a 3-month period of auto-titrating CPAP. The primary hypothesis is that nocturnal CPAP will improve neuropsychological functioning more than usual care alone. The secondary hypothesis is that the magnitude of improvement of neuropsychological function will be predicted by the severity of baseline sleepiness measures, sleep fragmentation and sleep apnoea. Neuropsychological tests and full polysomnography will be performed at baseline and 3 months with interim measures of sleepiness and symptoms of autonomic dysfunction measured weekly. Spirometry will be performed monthly. Neuropsychological tests will be administered by blinded assessors. Recruitment commenced in July 2009. The results of

  14. Correlation between subjective and objective nasal breathing assessments in examinees with nasal septum deformities.

    PubMed

    Savović, Slobodan; Smajić, Miroslav; Molnar, Slavko; Jovancević, Ljiljana; Buljcik-Cupić, Maja; Kljajić, Vladimir; Pilija, Vladimir

    2013-04-01

    Nasal obstruction is one of the most frequent disorders because of which patients see their Ear, Nose and Throath (ENT) doctors. Impaired nose breath ing is a subjective symptom and it often does not coincide with clinical nose findings and functional tests of breath ing function. Therefore, the aim of this study was to es tablish if there is an accordance between a subjective nose breathing assessment and objective methods (rhinoma nometry and acoustic rhinometry) in assessing nose breathing function in patients with diverse nasal septum deformity degrees, as well as to establish an accordance between these two objective methods. This study involved the total of 90 examinees divided into three groups. The group I consisted of examinees with nasal septum deformities less than 10 degrees. The group II consisted of examinees with nasal septum deformities ranged from 10 degrees to 15 degrees. The group III involved examinees with nasal septum deformities over 15 degrees. Each examinee had subjec tively graded his/her nasal breathing on the side of the nose septum deformity from 0 to 10, and afterwards the whole noses. Rhinomanometry and acoustic rhinometry were done on the side of the nasal septum deformities and after that on the other side of the nose using the Interacoustics SRE 2000 device. In the groups II and III there was a positive correlation between a subjective nose breathing assessment and rhinomanometric values both on the side of the nasal septum deformities and the nose as a whole, (p < 0.05), and no correlation between these traits in the group I (p > 0.05). In none of the exam ined groups correlation was found between a subjective nose breathing assessment and rhinometric values, both minimum cross-sectional area (MCA) and volume (VOL), both on the side of the nasal septum deformities and the nose as a whole (p > 0.05). There was no correlation found between rhinomanometric and rhinometric MCA and VOL values in either on the sides of nasal septum

  15. Application of segmented dental panoramic tomography among children: positive effect of continuing education in radiation protection.

    PubMed

    Pakbaznejad Esmaeili, Elmira; Waltimo-Sirén, Janna; Laatikainen, Tuula; Haukka, Jari; Ekholm, Marja

    2016-05-23

    Dental panoramic tomography is the most frequent examination among 7-12-year olds, according to the Radiation Safety and Nuclear Authority of Finland. At those ages, dental panoramic tomographs (DPTs) are mostly obtained for orthodontic reasons. Children's dose reduction by trimming the field size to the area of interest is important because of their high radiosensitivity. Yet, the majority of DPTs in this age group are still taken by using an adult programme and never by using a segmented programme. The purpose of the present study was to raise the awareness of dental staff with respect to children's radiation safety, to increase the application of segmented and child DPT programmes by further educating the whole dental team and to evaluate the outcome of the educational intervention. A five-step intervention programme, focusing on DPT field limitation possibilities, was carried out in community-based dental care as a part of mandatory continuing education in radiation protection. Application of segmented and child DPT programmes was thereafter prospectively followed up during a 1-year period and compared with our similar data from 2010 using a logistic regression analysis. Application of the child programme increased by 9% and the segmented programme by 2%, reaching statistical significance (odds ratios 1.68; 95% confidence interval 1.23-2.30; p-value < 0.001). The number of repeated exposures remained at an acceptable level. The segmented DPTs were most frequently taken from the maxillary lateral incisor-canine area. The educational intervention resulted in improvement of radiological practice in respect to radiation safety of children during dental panoramic tomography. Segmented and child DPT programmes can be applied successfully in dental practice for children.

  16. Application of segmented dental panoramic tomography among children: positive effect of continuing education in radiation protection

    PubMed Central

    Waltimo-Sirén, Janna; Laatikainen, Tuula; Haukka, Jari; Ekholm, Marja

    2016-01-01

    Objectives: Dental panoramic tomography is the most frequent examination among 7–12-year olds, according to the Radiation Safety and Nuclear Authority of Finland. At those ages, dental panoramic tomographs (DPTs) are mostly obtained for orthodontic reasons. Children's dose reduction by trimming the field size to the area of interest is important because of their high radiosensitivity. Yet, the majority of DPTs in this age group are still taken by using an adult programme and never by using a segmented programme. The purpose of the present study was to raise the awareness of dental staff with respect to children's radiation safety, to increase the application of segmented and child DPT programmes by further educating the whole dental team and to evaluate the outcome of the educational intervention. Methods: A five-step intervention programme, focusing on DPT field limitation possibilities, was carried out in community-based dental care as a part of mandatory continuing education in radiation protection. Application of segmented and child DPT programmes was thereafter prospectively followed up during a 1-year period and compared with our similar data from 2010 using a logistic regression analysis. Results: Application of the child programme increased by 9% and the segmented programme by 2%, reaching statistical significance (odds ratios 1.68; 95% confidence interval 1.23–2.30; p-value < 0.001). The number of repeated exposures remained at an acceptable level. The segmented DPTs were most frequently taken from the maxillary lateral incisor–canine area. Conclusions: The educational intervention resulted in improvement of radiological practice in respect to radiation safety of children during dental panoramic tomography. Segmented and child DPT programmes can be applied successfully in dental practice for children. PMID:27142159

  17. Blood pressure improvement with continuous positive airway pressure is independent of obstructive sleep apnea severity.

    PubMed

    Bakker, Jessie P; Edwards, Bradley A; Gautam, Shiva P; Montesi, Sydney B; Durán-Cantolla, Joaquín; Aizpuru, Felipe; Barandiarán, Felipe Aizpuru; Barbé, Ferran; Sánchez-de-la-Torre, Manuel; Malhotra, Atul

    2014-04-15

    We sought to perform a patient-level meta-analysis using the individual patient data of the trials identified in our previous study-level meta-analysis investigating the effect of positive airway pressure (PAP) treatment for obstructive sleep apnea (OSA) on blood pressure (BP). Patient-level meta-analysis. N/A. 968 adult OSA subjects without major comorbidities drawn from eight randomized controlled trials. Therapeutic PAP versus non-therapeutic control conditions (sham-PAP, pill placebo or standard care) over at least one week. The mean reductions in BP between PAP and non-therapeutic control arms were -2.27 mm Hg (95% CI -4.01 to -0.54) for systolic BP and -1.78 mm Hg (95% CI -2.99 to -0.58) for diastolic BP. The presence of uncontrolled hypertension at baseline was significantly associated with a reduction in systolic BP of 7.1 mm Hg and diastolic BP of 4.3 mm Hg after controlling for OSA severity (apnea-hypopnea index, Epworth Sleepiness Scale score, PAP level), patient demographics (age, gender, body mass index, use of antihypertensive medication/s), and measures of PAP efficacy (PAP adherence and treatment duration). OSA patients with uncontrolled hypertension are likely to gain the largest benefit from PAP in terms of a substantial reduction in BP, even after controlling for disease severity.

  18. [Differential proteins analysis among human nasal inverted papilloma and nasal polyposis and normal nasal mucosa].

    PubMed

    Meng, Qing-shu; Jin, Sheng; Zhang, Qiu-hang; Zhang, Man

    2010-04-01

    Proteomics-based approach was applied to analyze and compare the difference of proteins among human nasal inverted papilloma (NIP), nasal polyposis and normal nasal mucosa, in order to screen different proteins as marker. The total proteins of NIP, nasal polyposis and normal nasal mucosa were separated by two-dimensional gel electrophoresis (2-DE). Protein image obtained by using the gel of Calibrated GS-800 Densitometer system, and determined different protein spots. Six differential proteins between NIP and nasal polyp tissue were identified, which were galectin-1, Manganese-superoxide dismutase, galectin-7, trichostatin A, prohibitin and transferring. All of them were increased in NIP. Six differential proteins were possibly involved in NIP, which provided a new way for discriminating NIP from nasal polyposis. The data would be good for the establishment of NIP protein 2-DE map.

  19. Nasal reconstruction with articulated irradiated rib cartilage

    SciTech Connect

    Murakami, C.S.; Cook, T.A.; Guida, R.A. )

    1991-03-01

    Nasal structural reconstruction is a formidable task in cases where there is loss of support to both the nasal dorsum and tip. A multitude of surgical approaches and materials have been used for the correction of the saddle-nose deformity with varying degrees of success. Articulated irradiated rib cartilage inserted through an external rhinoplasty approach was used to reconstruct nasal deformities in 18 patients over a 6-year period. Simultaneous use of a midline forehead flap to reconstruct the overlying soft tissue was required in four cases. Follow-up ranged from 1 to 6 years (mean, 2.8 years). Results were rewarding in most cases with marked improvement in nasal support and airway. Revision and/or replacement secondary to trauma or warping of the graft was required in four cases. None of the patients exhibited infection, extrusion, or noticeable resorption. A description of the surgical technique, review of all the cases, and recommendation for continued use of this graft material are discussed.

  20. Continuous Positive Airway Pressure Improves Sleep and Daytime Sleepiness in Patients with Parkinson Disease and Sleep Apnea

    PubMed Central

    Neikrug, Ariel B.; Liu, Lianqi; Avanzino, Julie A.; Maglione, Jeanne E.; Natarajan, Loki; Bradley, Lenette; Maugeri, Alex; Corey-Bloom, Jody; Palmer, Barton W.; Loredo, Jose S.; Ancoli-Israel, Sonia

    2014-01-01

    Study Objectives: Obstructive sleep apnea (OSA), common in Parkinson disease (PD), contributes to sleep disturbances and daytime sleepiness. We assessed the effect of continuous positive airway pressure (CPAP) on OSA, sleep, and daytime sleepiness in patients with PD. Design: This was a randomized placebo-controlled, crossover design. Patients with PD and OSA were randomized into 6 w of therapeutic treatment or 3 w of placebo followed by 3 w of therapeutic treatment. Patients were evaluated by polysomnography (PSG) and multiple sleep latency test (MSLT) pretreatment (baseline), after 3 w, and after 6 w of CPAP treatment. Analyses included mixed models, paired analysis, and within-group analyses comparing 3 w to 6 w of treatment. Setting: Sleep laboratory. Participants: Thirty-eight patients with PD (mean age = 67.2 ± 9.2 y; 12 females). Intervention: Continuous positive airway pressure. Measurements: PSG outcome measures: sleep efficiency, %sleep stages (N1, N2, N3, R), arousal index, apnea-hypopnea index (AHI), and % time oxygen saturation < 90% (%time SaO2 < 90%). MSLT outcome measures: mean sleep-onset latency (MSL). Results: There were significant group-by-time interactions for AHI (P < 0.001), % time SaO2 < 90% (P = 0.02), %N2 (P = 0.015) and %N3 (P = 0.014). Subjects receiving therapeutic CPAP showed significant decrease in AHI, %time SaO2 < 90%, %N2, and significant increase in %N3 indicating effectiveness of CPAP in the treatment of OSA, improvement in nighttime oxygenation, and in deepening sleep. The paired sample analyses revealed that 3 w of therapeutic treatment resulted in significant decreases in arousal index (t = 3.4, P = 0.002). All improvements after 3 w were maintained at 6 w. Finally, 3 w of therapeutic CPAP also resulted in overall decreases in daytime sleepiness (P = 0.011). Conclusions: Therapeutic continuous positive airway pressure versus placebo was effective in reducing apnea events, improving oxygen saturation, and deepening sleep in

  1. The European positional paper on rhinosinusitis and nasal polyps: has the introduction of guidance on the management of sinus disease affected uptake of surgery and acute admissions for sinusitis?

    PubMed

    Cosway, Ben; Tomkinson, Alun; Owens, David

    2013-03-01

    Rhinosinusitis is a common condition with adults experiencing 2-5 episodes per year. The European Positional Paper on Rhinosinusitis and Nasal Polyps (EP3OS) published in 2005 and updated in 2007 provided evidence-based guidelines on the management of sinus disease promoting a conservative approach to treatment. This study examines the effect of EP3OS on sinus surgery uptake and acute admissions for sinusitis in England and Wales. A retrospective study using the national electronic health databases of England (Hospital Episodes Statistics, HES online) and Wales (Patient Episodes Database of Wales, PEDW) was undertaken from 2000 to 2010 using the OPCS-4 codes E12-E17 (sinus surgery) and ICD10 code J01 (acute admission for sinusitis). Data were analysed for effect following the introduction of the EP3OS in 2005 using linear regression and Chi squared analysis. 116,370 sinus procedures and 10,916 acute admissions for sinusitis were made during the study period. No significant decrease in sinus surgery procedures occurred following the introduction of the EP3OS as may have been expected (p > 0.05), although subgroup analysis suggested a significant increase in Wales (p < 0.05). In addition, significant increases in acute admissions for sinusitis were observed following the introduction of EP3OS (p < 0.05). However, subgroup analysis suggested this was not the case in Wales (p > 0.05). The EP3OS appears to have had little impact on the rates of sinus surgery but more conservative approaches to managing of sinus disease may have led to an increase in acute admissions. Further research is required to investigate whether changes in practice were adopted.

  2. Using acoustic sensors to discriminate between nasal and mouth breathing.

    PubMed

    Curran, Kevin; Yuan, Peng; Coyle, Damian

    2012-01-01

    The recommendation to change breathing patterns from the mouth to the nose can have a significantly positive impact upon the general well being of the individual. We classify nasal and mouth breathing by using an acoustic sensor and intelligent signal processing techniques. The overall purpose is to investigate the possibility of identifying the differences in patterns between nasal and mouth breathing in order to integrate this information into a decision support system which will form the basis of a patient monitoring and motivational feedback system to recommend the change from mouth to nasal breathing.

  3. [Nasal foreign body in infants].

    PubMed

    Claudet, I; Salanne, S; Debuisson, C; Maréchal, C; Rekhroukh, H; Grouteau, E

    2009-09-01

    principal symptoms. The right nostril was the predominant location (60%). This difference tended to disappear in the group of children aged less than 4 years. Five children had bilateral NFB. Nonorganic compounds accounted for 80% of the NFB: plastic beads or balls (39%), plastic or toy parts (20%), stones or pebbles (11%), and paper (6%). The extraction was instrumental in 82% of cases, and 26% of patients were referred to an ENT specialist when PED attempts were unsuccessful. One child needed hospitalization for extraction under general anesthesia of two beads located deep in the same nostril. No complication occurred. Five children had repeated accidents within an average delay of 6 months. Often benign, this frequent accident can be serious in case of batteries or neodymium magnet insertion: the extraction becomes an emergency because of risks of nasal mucosa necrosis and/or nasal septum perforation. In other cases, positive pressure techniques (the parent's kiss or its variants) could be tried first in the emergency department or at home at the time of a call to emergency services before a medical visit.

  4. Impact of airflow communication between nasal cavities on nasal ventilation.

    PubMed

    Zhou, Bing; Huang, Qian; Cui, Shunjiu; Liu, Yingxi; Han, Demin

    2013-01-01

    To investigate the impact of airflow communication between bilateral nostril sides on nasal ventilation. In addition, we try to validate the efficacy of the Draf III procedure from the aerodynamics perspective. One health model and two disease models were constructed. These included 2 patients with nasal septum perforation and 1 patient who received the Draf III procedure. With the computational fluid dynamics method, indices such as airflow velocity and wall shear stress in the nasal cavity were detected and compared among the 3 subjects. The main pathway for airflow in the nasal cavity is the common meatus. Little airflow exchange occurred in the patient who underwent the Draf III procedure, and the wall shear stress around the communication site was as low as in the adjacent areas. However, when airflow communication occurred in the lower part of the nasal cavity, the airflow velocity and wall shear stress were obviously altered, and the ventilation function of the nasal cavity was impaired. Airflow communication in the upper part of the nasal cavity has little impact on nasal ventilation. Nonetheless, airflow communication occurring in the lower part of the nasal cavity disturbs the overall airflow distribution and a repair procedure is necessary. © 2013 S. Karger AG, Basel.

  5. Triclosan Promotes Staphylococcus aureus Nasal Colonization

    PubMed Central

    Syed, Adnan K.; Ghosh, Sudeshna; Love, Nancy G.; Boles, Blaise R.

    2014-01-01

    ABSTRACT The biocide triclosan is used in many personal care products, including toothpastes, soaps, clothing, and medical equipment. Consequently, it is present as a contaminant in the environment and has been detected in some human fluids, including serum, urine, and milk. Staphylococcus aureus is an opportunistic pathogen that colonizes the noses and throats of approximately 30% of the population. Colonization with S. aureus is known to be a risk factor for several types of infection. Here we demonstrate that triclosan is commonly found in the nasal secretions of healthy adults and the presence of triclosan trends positively with nasal colonization by S. aureus. We demonstrate that triclosan can promote the binding of S. aureus to host proteins such as collagen, fibronectin, and keratin, as well as inanimate surfaces such as plastic and glass. Lastly, triclosan-exposed rats are more susceptible to nasal colonization with S. aureus. These data reveal a novel factor that influences the ability of S. aureus to bind surfaces and alters S. aureus nasal colonization. PMID:24713325

  6. Some acoustic features of nasal and nasalized vowels: a target for vowel nasalization.

    PubMed

    Feng, G; Castelli, E

    1996-06-01

    In order to characterize acoustic properties of nasal and nasalized vowels, these sounds will be considered as a dynamic trend from an oral configuration toward an [n]-like configuration. The latter can be viewed as a target for vowel nasalization. This target corresponds to the pharyngonasal tract and it can be modeled, with some simplifications, by a single tract without any parallel paths. Thus the first two resonance frequencies (at about 300 and 1000 Hz) characterize this target well. A series of measurements has been carried out in order to describe the acoustic characteristics of the target. Measured transfer functions confirm the resonator nature of the low-frequency peak. The introduction of such a target allows the conception of the nasal vowels as a trend beginning with a simple configuration, which is terminated in the same manner, so allowing the complex nasal phenomena to be bounded. A complete study of pole-zero evolutions for the nasalization of the 11 French vowels is presented. It allows the proposition of a common strategy for the nasalization of all vowels, so a true nasal vowel can be placed in this nasalization frame. The measured transfer functions for several French nasal vowels are also given.

  7. Nasal airflow during respiratory cycle.

    PubMed

    Chung, Seung-Kyu; Son, Young Rak; Shin, Seok Jae; Kim, Sung-Kyun

    2006-01-01

    Knowledge on the airflow patterns in the nasal cavity is essential to understanding the function of the nasal cavity. This study has attempted to observe the breath cycle of nasal airflow during respiration at rest. We constructed a nasal cavity model by rapid prototyping using 1.25-mm-thick CT data and devised a piston pump driven by a cam, to simulate respiration at rest. The airflow was evaluated with particle image velocimetry and visualized in coronal reconstructed images. During the inspiration, a maximal velocity was observed at the valve area and the main stream occurred in the middle and superior airways. During the expiration, main stream was noted in the middle airway and was slow compared with the flow during inspiration. Vortexes were observed between inspiration and expiration. This result widens our knowledge of nasal airflow and this technique will allow a more physiological understanding of nasal operations.

  8. Impact of continuous positive airway pressure (CPAP) on quality of life in patients with obstructive sleep apnea (OSA).

    PubMed

    Batool-Anwar, Salma; Goodwin, James L; Kushida, Clete A; Walsh, James A; Simon, Richard D; Nichols, Deborah A; Quan, Stuart F

    2016-12-01

    Obstructive sleep apnea is a chronic illness with increasing prevalence. In addition to associated cardiovascular comorbidities, obstructive sleep apnea syndrome has been linked to poor quality of life, occupational accidents, and motor vehicle crashes secondary to excessive daytime sleepiness. Although continuous positive airway pressure is the gold standard for sleep apnea treatment, its effects on quality of life are not well defined. In the current study we investigated the effects of treatment on quality of life using the data from the Apnea Positive Pressure Long-term Efficacy Study (APPLES), a randomized controlled trial of continuous positive airway pressure (CPAP) versus sham CPAP. The Calgary Sleep Apnea Quality of Life Index (SAQLI) was used to assess quality of life. Overall we found no significant improvement in quality of life among sleep apnea patients after CPAP treatment. However, after stratifying by OSA severity, it was found that long-term improvement in quality of life might occur with the use of CPAP in people with severe and possibly moderate sleep apnea, and no demonstrable improvement in quality of life was noted among participants with mild obstructive sleep apnea. © 2016 European Sleep Research Society.

  9. A subsequent positive stroke developing in the channel of preceding negative stroke and containing bipolar continuing current

    NASA Astrophysics Data System (ADS)

    Zhu, Y.; Rakov, V. A.; Tran, M. D.; Lu, W.

    2016-09-01

    A bipolar cloud-to-ground lightning flash was observed to exhibit two types of polarity reversal associated with the first two strokes separated by a not unduly long time interval of 70 ms. The first stroke was negative and had a peak current of -101 kA. The second stroke was positive, had a peak current of 16 kA and was followed by a 122 ms long bipolar continuing current. The first two strokes, including the bipolar continuing current, occurred in the same channel to ground, whose imaged 2-D length was 4.2 km. The occurrence of positive stroke in the negative-stroke channel is highly unusual. The 2-D speed versus height profiles for the negative stepped leader of the first stroke and, for the first time, for the positive leader in the previously conditioned, first-stroke channel were examined and the average speeds were found to be 4.7 × 105 m/s and 7.2 × 105 m/s, respectively.

  10. Nasal nitric oxide is dependent on sinus obstruction in allergic rhinitis.

    PubMed

    Suojalehto, Hille; Vehmas, Tapio; Lindström, Irmeli; Kennedy, David W; Kilpeläinen, Maritta; Plosila, Tuomas; Savukoski, Sauli; Sipilä, Jukka; Varpula, Matti; Wolff, Henrik; Alenius, Harri; Toskala, Elina

    2014-06-01

    The aim of this study was to evaluate the associations between nasal nitric oxide and nasal symptoms, sinus opacification, and markers of allergic inflammation in allergic and in nonallergic rhinitis while taking into account the effect of sinus obstruction. We studied 175 young adult subjects divided into three groups: 1) allergic rhinitis, 2) nonallergic rhinitis, and 3) controls. We measured nasal nitric oxide using the breath-holding method and exhaled nitric oxide and scored semiquantitatively nasal computed tomography scans for opacification and obstruction. We also assessed the visual analogue scores of nasal symptoms, eosinophil count, and interleukin-13 mRNA levels in nasal biopsies. The level of nasal nitric oxide correlated with exhaled nitric oxide (r = 0.377, P < .001). In allergic rhinitis, nasal nitric oxide was elevated when compared to the controls, and an inverse correlation existed between the nasal nitric oxide level and sinus ostial obstruction (r = -0.272, P = .013). In nonallergic rhinitis, the level of nasal nitric oxide was similar to that of the controls. In allergic rhinitis, nasal nitric oxide correlated positively with the opacification score (r = 0.250, P = .033) and the nasal eosinophil count (r = 0.293, P = .030) of patients without a marked sinus ostial obstruction. Sinus ostial obstruction lowers the level of nasal nitric oxide and reduces its value as an indicator of allergic mucosal inflammation. A high nasal nitric oxide level may be a useful marker of eosinophilic inflammation in the nasal cavity and indicate the absence of marked sinus ostial obstruction. 3b. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Effects of Continuous Positive Airway Pressure on Neurocognitive Function in Obstructive Sleep Apnea Patients: The Apnea Positive Pressure Long-term Efficacy Study (APPLES)

    PubMed Central

    Kushida, Clete A.; Nichols, Deborah A.; Holmes, Tyson H.; Quan, Stuart F.; Walsh, James K.; Gottlieb, Daniel J.; Simon, Richard D.; Guilleminault, Christian; White, David P.; Goodwin, James L.; Schweitzer, Paula K.; Leary, Eileen B.; Hyde, Pamela R.; Hirshkowitz, Max; Green, Sylvan; McEvoy, Linda K.; Chan, Cynthia; Gevins, Alan; Kay, Gary G.; Bloch, Daniel A.; Crabtree, Tami; Dement, William C.

    2012-01-01

    Study Objective: To determine the neurocognitive effects of continuous positive airway pressure (CPAP) therapy on patients with obstructive sleep apnea (OSA). Design, Setting, and Participants: The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blind, 2-arm, sham-controlled, multicenter trial conducted at 5 U.S. university, hospital, or private practices. Of 1,516 participants enrolled, 1,105 were randomized, and 1,098 participants diagnosed with OSA contributed to the analysis of the primary outcome measures. Intervention: Active or sham CPAP Measurements: Three neurocognitive variables, each representing a neurocognitive domain: Pathfinder Number Test-Total Time (attention and psychomotor function [A/P]), Buschke Selective Reminding Test-Sum Recall (learning and memory [L/M]), and Sustained Working Memory Test-Overall Mid-Day Score (executive and frontal-lobe function [E/F]) Results: The primary neurocognitive analyses showed a difference between groups for only the E/F variable at the 2 month CPAP visit, but no difference at the 6 month CPAP visit or for the A/P or L/M variables at either the 2 or 6 month visits. When stratified by measures of OSA severity (AHI or oxygen saturation parameters), the primary E/F variable and one secondary E/F neurocognitive variable revealed transient differences between study arms for those with the most severe OSA. Participants in the active CPAP group had a significantly greater ability to remain awake whether measured subjectively by the Epworth Sleepiness Scale or objectively by the maintenance of wakefulness test. Conclusions: CPAP treatment improved both subjectively and objectively measured sleepiness, especially in individuals with severe OSA (AHI > 30). CPAP use resulted in mild, transient improvement in the most sensitive measures of executive and frontal-lobe function for those with severe disease, which suggests the existence of a complex OSA-neurocognitive relationship

  12. Modafinil Increases Awake EEG Activation and Improves Performance in Obstructive Sleep Apnea during Continuous Positive Airway Pressure Withdrawal

    PubMed Central

    Wang, David; Bai, Xiao Xue; Williams, Shaun C.; Hua, Shu Cheng; Kim, Jong-Won; Marshall, Nathaniel S.; D'Rozario, Angela; Grunstein, Ronald R.

    2015-01-01

    Objectives: We examined the changes in waking electroencephalography (EEG) biomarkers with modafinil during continuous positive airway pressure (CPAP) withdrawal in patients with obstructive sleep apnea (OSA) to investigate neurophysiological evidence for potential neurocognitive improvements. Design: Randomized double-blind placebo-controlled crossover study. CPAP was used for the first night and then withdrawn for 2 subsequent nights. Each morning after the 2 CPAP withdrawal nights, patients received either 200 mg modafinil or placebo. After a 5-w washout, the procedure repeated with the crossover drug. Setting: University teaching hospital. Participants: Stable CPAP users (n = 23 men with OSA) Measurement and Results: Karolinska Drowsiness Test (KDT) (awake EEG measurement with eyes open and closed), Psychomotor Vigilance Task (PVT), and driving simulator Performance were assessed bihourly during the 3 testing days following CPAP treatment and CPAP withdrawal nights. Compared to placebo, modafinil significantly increased awake EEG activation (faster EEG frequency) with increased alpha/delta (A/D) ratio (P < 0.0001) and fast ratio = (alpha+beta)/(delta+theta) (P < 0.0001) across the 2 days of CPAP withdrawal. The A/D ratio significantly correlated with the driving simulator response time (P = 0.015), steering variation (P = 0.002), and PVT reaction time (P = 0.006). In contrast, individual EEG band power of alpha, beta, theta, and delta did not correlate with any neurocognitive performance. Conclusions: Modafinil administration during continuous positive airway pressure (CPAP) withdrawal increased awake EEG activation, which correlated to improved performance. This study provides supporting neurophysiological evidence that modafinil is a potential short-term treatment option during acute CPAP withdrawal. Citation: Wang D, Bai XX, Williams SC, Hua SC, Kim JW, Marshall NS, D'Rozario A, Grunstein RR. Modafinil increases awake EEG activation and improves performance

  13. Nasal high flow treatment in preterm infants.

    PubMed

    Roberts, Calum T; Hodgson, Kate A

    2017-01-01

    Nasal High Flow (HF) is a mode of 'non-invasive' respiratory support for preterm infants, with several potential modes of action, including generation of distending airway pressure, washout of the nasopharyngeal dead space, reduction of work of breathing, and heating and humidification of inspired gas. HF has several potential advantages over continuous positive airway pressure (CPAP), the most commonly applied form of non-invasive support, such as reduced nasal trauma, ease of use, and infant comfort, which has led to its rapid adoption into neonatal care. In recent years, HF has become a well-established and commonly applied treatment in neonatal care. Recent trials comparing HF and CPAP as primary support have had differing results. Meta-analyses suggest that primary HF results in an increased risk of treatment failure, but that 'rescue' CPAP use in those infants with HF failure results in no greater risk of mechanical ventilation. Even in studies with higher rates of HF failure, the majority of infants were successfully treated with HF, and rates of important neonatal morbidities did not differ between treatment groups. Importantly, these studies have included only infants born at ≥28 weeks' gestational age (GA). The decision whether to apply primary HF will depend on the value placed on its advantages over CPAP by clinicians, the approach to surfactant treatment, and the severity of respiratory disease in the relevant population of preterm infants. Post-extubation HF use results in similar rates of treatment failure, mechanical ventilation, and adverse events compared to CPAP. Post-extubation HF appears most suited to infants ≥28 weeks; there are few published data for infants below this gestation, and available evidence suggests that these infants are at high risk of HF failure, although rates of intubation and other morbidities are similar to those seen with CPAP. There is no evidence that using HF to 'wean' off CPAP allows for respiratory support to

  14. Continuous positive airway pressure improves sleep and daytime sleepiness in patients with Parkinson disease and sleep apnea.

    PubMed

    Neikrug, Ariel B; Liu, Lianqi; Avanzino, Julie A; Maglione, Jeanne E; Natarajan, Loki; Bradley, Lenette; Maugeri, Alex; Corey-Bloom, Jody; Palmer, Barton W; Loredo, Jose S; Ancoli-Israel, Sonia

    2014-01-01

    Obstructive sleep apnea (OSA), common in Parkinson disease (PD), contributes to sleep disturbances and daytime sleepiness. We assessed the effect of continuous positive airway pressure (CPAP) on OSA, sleep, and daytime sleepiness in patients with PD. This was a randomized placebo-controlled, crossover design. Patients with PD and OSA were randomized into 6 w of therapeutic treatment or 3 w of placebo followed by 3 w of therapeutic treatment. Patients were evaluated by polysomnography (PSG) and multiple sleep latency test (MSLT) pretreatment (baseline), after 3 w, and after 6 w of CPAP treatment. Analyses included mixed models, paired analysis, and within-group analyses comparing 3 w to 6 w of treatment. Sleep laboratory. Thirty-eight patients with PD (mean age = 67.2 ± 9.2 y; 12 females). Continuous positive airway pressure. PSG OUTCOME MEASURES: sleep efficiency, %sleep stages (N1, N2, N3, R), arousal index, apnea-hypopnea index (AHI), and % time oxygen saturation < 90% (%time SaO2 < 90%). MSLT outcome measures: mean sleep-onset latency (MSL). There were significant group-by-time interactions for AHI (P < 0.001), % time SaO2 < 90% (P = 0.02), %N2 (P = 0.015) and %N3 (P = 0.014). Subjects receiving therapeutic CPAP showed significant decrease in AHI, %time SaO2 < 90%, %N2, and significant increase in %N3 indicating effectiveness of CPAP in the treatment of OSA, improvement in nighttime oxygenation, and in deepening sleep. The paired sample analyses revealed that 3 w of therapeutic treatment resulted in significant decreases in arousal index (t = 3.4, P = 0.002). All improvements after 3 w were maintained at 6 w. Finally, 3 w of therapeutic CPAP also resulted in overall decreases in daytime sleepiness (P = 0.011). Therapeutic continuous positive airway pressure versus placebo was effective in reducing apnea events, improving oxygen saturation, and deepening sleep in patients with Parkinson disease and obstructive sleep apnea. Additionally, arousal index was reduced

  15. Established vascular effects of continuous positive airway pressure therapy in patients with obstructive sleep apnoea—an update

    PubMed Central

    Wons, Annette Marie

    2015-01-01

    The aim of this review was to summarize the current data from randomised controlled trials (RCTs) on vascular effects of continuous positive airway pressure (CPAP) therapy in patients with obstructive sleep apnoea (OSA). There is good evidence from RCTs that CPAP lowers blood pressure (BP) to a clinically significant amount. The effect seems to be dependent on the hours of nightly CPAP usage. Data from RCTs have also proven a beneficial effect of CPAP on measures of vascular function such as endothelial function and arterial stiffness. However, there is still a lack of evidence from RCTs proving that CPAP reduces vascular events and mortality. PMID:26101649

  16. Craniofacial Deviations in the Children With Nasal Obstruction.

    PubMed

    Ant, Ayca; Kemaloglu, Yusuf Kemal; Yilmaz, Metin; Dilci, Alper

    2017-01-20

    Nasal obstruction mainly caused by adenoid hypertrophy in children affects the craniofacial growth and development process, and the craniofacial deviations and/or differences reported in the children are very similar to those in the adults with obstructive sleep apnea syndrome (OSAS). The authors aimed to look for relationships of the linear craniofacial dimensions in the children suffering from nasal obstruction with age, de