Sample records for nasal inspiratory flow

  1. Variations in peak nasal inspiratory flow among healthy students after using saline solutions.

    PubMed

    Olbrich Neto, Jaime; Olbrich, Sandra Regina Leite Rosa; Mori, Natália Leite Rosa; Oliveira, Ana Elisa de; Corrente, José Eduardo

    2016-01-01

    Nasal hygiene with saline solutions has been shown to relieve congestion, reduce the thickening of the mucus and keep nasal cavity clean and moist. Evaluating whether saline solutions improve nasal inspiratory flow among healthy children. Students between 8 and 11 years of age underwent 6 procedures with saline solutions at different concentrations. The peak nasal inspiratory flow was measured before and 30 min after each procedure. Statistical analysis was performed by means of t test, analysis of variance, and Tukey's test, considering p<0.05. We evaluated 124 children at all stages. There were differences on the way a same concentration was used. There was no difference between 0.9% saline solution and 3% saline solution by using a syringe. The 3% saline solution had higher averages of peak nasal inspiratory flow, but it was not significantly higher than the 0.9% saline solution. It is important to offer various options to patients. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  2. Evaluation of polyvinylidene fluoride nasal sensor to assess deviated nasal septum in comparision with peak nasal inspiratory flow measurements.

    PubMed

    Manjunatha, Roopa G; Rajanna, K; Mahapatra, D Roy; Prakash, Surya

    2014-01-01

    Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.

  3. Inspiratory Tube Condensation During High-Flow Nasal Cannula Therapy: A Bench Study.

    PubMed

    Chikata, Yusuke; Unai, Kazuaki; Izawa, Masayo; Okuda, Nao; Oto, Jun; Nishimura, Masaji

    2016-03-01

    High-flow nasal cannula (HFNC) therapy provides better humidification than conventional oxygen therapy. To allay loss of vapor as condensation, a servo-controlled heating wire is incorporated in the inspiratory tube, but condensation is not completely avoidable. We investigated factors that might affect condensation: thermal characteristics of the inspiratory tube, HFNC flow, and ambient temperature. We evaluated 2 types of HFNC tubes, SLH Flex 22-mm single tube and RT202. Both tubes were connected to a heated humidifier with water reservoir. HFNC flow was set at 20, 40, and 60 L/min, and FIO2 was set at 0.21. Air conditioning was used maintain ambient temperature at close to either 20 or 25°C. We weighed the tubes on a digital scale before (0 h) and at 3, 6, and 24 h after, turning on the heated humidifier, and calculated the amount of condensation by simple subtraction. The amount of distilled water used during 24 h was also recorded. At 25°C, there was little condensation, but at 20°C and HFNC flow of 20, 40, and 60 L/min for 24 h, the amount of condensation with the SLH was 50.2 ± 10.7, 44.3 ± 17.7, and 56.6 ± 13.9 mg, and the amount with the RT202 was 96.0 ± 35.1, 72.8 ± 8.2, and 64.9 ± 0.8 mg. When ambient temperature was set to 20°C, condensation with the RT202 was statistically significantly greater than with the SLH at all flow settings (P < .001). Ambient temperature statistically significantly influenced the amount of condensation in the tubes. Copyright © 2016 by Daedalus Enterprises.

  4. Peak nasal inspiratory flow correlates with quality of life in functional endoscopic sinus surgery.

    PubMed

    Whitcroft, K L; Andrews, P J; Randhawa, P S

    2017-12-01

    Whilst nasal function and airflow improve subjectively following functional endoscopic sinus surgery (FESS), a clinically useful and objective tool for quantifying such improvement is lacking. The peak nasal inspiratory flow (PNIF) metre offers convenient and objective measures of nasal patency. However, it has not yet been established whether changes in PNIF after surgery reflect changes in subjective disease burden. In this study we aimed to determine whether changes in PNIF correlate with commonly used subjective symptom and quality of life outcome measures following FESS for chronic rhinosinusitis (CRS). Prospective cohort. Royal National Throat Nose and Ear Hospital. Thirty-seven patients undergoing FESS for CRS, with or without polyps (21 male, mean age 48.8). PNIF, "SNOT-22", "NOSE" and "VAS" questionnaires were performed before and after surgery. In all patients, there was a strong negative correlation between change in PNIF and change in "SNOT-22" score following surgery (Pearson r=-.64, P<.0001). Strong negative correlations were also seen during subgroup analysis of patients with and without polyps (r=-.57, P=.006 and r=-.67, P=.005, respectively). Change in PNIF correlated significantly with change in "NOSE" score following surgery in all patients and those without polyps (r=-.54, P=.0005 and r=-.68, P=.003). There were no significant correlations between PNIF and VAS (nasal obstruction). Changes in PNIF after FESS appear to best reflect improvements in quality of life in CRS as measured using the "SNOT-22" questionnaire. © 2017 John Wiley & Sons Ltd.

  5. Pressure-flow specificity of inspiratory muscle training.

    PubMed

    Tzelepis, G E; Vega, D L; Cohen, M E; Fulambarker, A M; Patel, K K; McCool, F D

    1994-08-01

    The inspiratory muscles (IM) can be trained by having a subject breathe through inspiratory resistive loads or by use of unloaded hyperpnea. These disparate training protocols are characterized by high inspiratory pressure (force) or high inspiratory flow (velocity), respectively. We tested the hypothesis that the posttraining improvements in IM pressure or flow performance are specific to training protocols in a way that is similar to force-velocity specificity of skeletal muscle training. IM training was accomplished in 15 normal subjects by use of three protocols: high inspiratory pressure-no flow (group A, n = 5), low inspiratory pressure-high flow (group B, n = 5), and intermediate inspiratory pressure and flow (group C, n = 5). A control group (n = 4) did no training. Before and after training, we measured esophageal pressure (Pes) and inspiratory flow (VI) during single maximal inspiratory efforts against a range of external resistances including an occluded airway. Efforts originated below relaxation volume (Vrel), and peak Pes and VI were measured at Vrel. Isovolume maximal Pes-VI plots were constructed to assess maximal inspiratory pressure-flow performance. Group A (pressure training) performed 30 maximal static inspiratory maneuvers at Vrel daily, group B (flow training) performed 30 sets of three maximal inspiratory maneuvers with no added external resistance daily, and group C (intermediate training) performed 30 maximal inspiratory efforts on a midrange external resistance (7 mm ID) daily. Subjects trained 5 days/wk for 6 wk. Data analysis included comparison of posttraining Pes-VI slopes among training groups.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Inspiratory flow pattern in humans.

    PubMed

    Lafortuna, C L; Minetti, A E; Mognoni, P

    1984-10-01

    The theoretical estimation of the mechanical work of breathing during inspiration at rest is based on the common assumption that the inspiratory airflow wave is a sine function of time. Different analytical studies have pointed out that from an energetic point of view a rectangular wave is more economical than a sine wave. Visual inspection of inspiratory flow waves recorded during exercise in humans and various animals suggests that a trend toward a rectangular flow wave may be a possible systematic response of the respiratory system. To test this hypothesis, the harmonic content of inspiratory flow waves that were recorded in six healthy subjects at rest, during exercise hyperventilation, and during a maximum voluntary ventilation (MVV) maneuver were evaluated by a Fourier analysis, and the results were compared with those obtained on sinusoidal and rectangular models. The dynamic work inherent in the experimental waves and in the sine-wave model was practically the same at rest; during exercise hyperventilation and MVV, the experimental wave was approximately 16-20% more economical than the sinusoidal one. It was concluded that even though at rest the sinusoidal model is a reasonably good approximation of inspiratory flow, during exercise and MVV, a physiological controller is probably operating in humans that can select a more economical inspiratory pattern. Other peculiarities of airflow wave during hyperventilation and some optimization criteria are also discussed.

  7. Prediction of inspiratory flow shapes during sleep with a mathematic model of upper airway forces.

    PubMed

    Aittokallio, Tero; Gyllenberg, Mats; Saaresranta, Tarja; Polo, Olli

    2003-11-01

    To predict the airflow dynamics during sleep using a mathematic model that incorporates a number of static and dynamic upper airway forces, and to compare the numerical results to clinical flow data recorded from patients with sleep-disordered breathing on and off various treatment options. Upper airway performance was modeled in virtual subjects characterized by parameter settings that describe common combinations of risk factors predisposing to upper airway collapse during sleep. The treatments effect were induced by relevant changes of the initial parameter values. Computer simulations at our website (http://www.utu.fi/ml/sovmat/bio/). Risk factors considered in the simulation settings were sex, obesity, pharyngeal collapsibility, and decreased phasic activity of pharyngeal muscles. The effects of weight loss, pharyngeal surgery, nasal continuous positive airway pressure, and respiratory stimulation on the inspiratory flow characteristics were tested with the model. Numerical predictions were investigated by means of 3 measurable inspiratory airflow characteristics: initial slope, total volume, and flow shape. The model was able to reproduce the inspiratory flow shape characteristics that have previously been described in the literature. Simulation results also supported the observations that a multitude of factors underlie the pharyngeal collapse and, therefore, certain medical therapies that are effective in some conditions may prove ineffective in others. A mathematic model integrating the current knowledge of upper airway physiology is able to predict individual treatment responses. The model provides a framework for designing novel and potentially feasible treatment alternatives for sleep-disordered breathing.

  8. Nasal patency and otorhinolaryngologic-orofacial features in children.

    PubMed

    Milanesi, Jovana de Moura; Berwig, Luana Cristina; Schuch, Luiz Henrique; Ritzel, Rodrigo Agne; Silva, Ana Maria Toniolo da; Corrêa, Eliane Castilhos Rodrigues

    2017-11-21

    Nasal obstruction is a common symptom in childhood, related to rhinitis and pharyngeal tonsil hypertrophy. In the presence of nasal obstruction, nasal patency may be reduced, and nasal breathing is replaced by mouth breathing. Orofacial and otorhinolaryngologic changes are related to this breathing mode. Objective evaluation of upper airways may be obtained through nasal patency measurement. To compare nasal patency and otorhinolaryngologic-orofacial features in children. One hundred and twenty three children, 6-12 year-old, and of both sexes underwent speech therapy evaluation, according to Orofacial Myofunctional Evaluation protocol, clinical and endoscopic otorhinolaryngologic examination and nasal patency measurement, using the absolute and predicted (%) peak nasal inspiratory flow values. Lower values of absolute and estimated peak nasal inspiratory flow values were found in children with restless sleep (p=0.006 and p=0.002), nasal obstruction report (p=0.027 and p=0.023), runny nose (p=0.004 and p=0.012), unsystematic lip closure during mastication (p=0.040 and p=0.026), masticatory speed reduced (p=0.006 and p=0.008) and altered solid food swallowing (p=0.006 and p=0.001). Absolute peak nasal inspiratory flow was lower in children with pale inferior turbinate (p=0.040), reduced hard palate width (p=0.037) and altered speech (p=0.004). Higher absolute values were found in children with increased tongue width (p=0.027) and, higher absolute and predicted (%) in children with mild everted lip (p=0.008 and p=0.000). Nasal patency was lower in children with restless sleep, rhinitis signs and symptoms, hard palate width reduced and with changes in mastication, deglutition and speech functions. It is also emphasized that most of the children presented signs and symptom of allergic rhinitis. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. [PNIF (Peak nasal inspiratory flow) as a method for assessing nasal airway patency in the ECAP (Epidemiology of Allergic Disorders in Poland) multicenter study].

    PubMed

    Krzych-Fałta, Edyta; Lusawa, Adam; Samoliński, Bolesław

    2012-01-01

    The aim of the study was to evaluate the usefulness of PNIF in assessing nasal airway patency based on test results. The sample in the study was a group of 4 674 subjects, including 1291 people aged 6-7 years (woman 643, men 648), 1293 people aged 13-14 years (woman 625, men 668) and 2090 adults (woman 1284, men 806). The research method employed in the study was the measurement of peak nasal inspiratory flow using a peak flow meter with a suitable mask as used in rhinomanometry tests and with a flow rate ranging from 20 to 350 l/min. The study was conducted in 2006-2008 at the following centres: Katowice, Wroclaw, Krakow, Lublin, Warszawa, Bydgoszcz, Gdansk and in the rural areas of the former province of Zamosc. For the purposes of the study, the average values for the subjects were calculated for a number of criteria: - subject age: The average PNIF value was 52,41/min for subjects aged 6-7 years(n=1291), 94.7 l/min for subjects aged 13-14 (n=1293) and 108.0 l/min for the adults (n=2090). Indeed statistical dependences for all aged groups were observed on level p<0,0005. -diagnosis: The average PNIF value for healthy was 52,3 l/min p=0,338 for subjects aged 6-7 years (n=680), 97,3 l/min p=0,279 for subjects aged 13-14 (n=640) and 111,7 l/min p=0,438 for the adults (n=1035) and for allergic rhinitis PNIF value was 50,41/min p=0,028 for subjects aged 6-7 years(n=310), 93,3 l/min p=0,299 for subjects aged 13-14 (n=389) and 107,71 1/min p=0,276 for the adults (n=623) and asthma PNIF value was 51,6/min for subjects aged 6-7 years(n=149) 87,3 l/min p=0,062 for subjects aged 13-14 (n=145) p=0,097 and 105,3 l/min p=0,13 for the adults (n=198) -exposure to tobacco smoke (adults): passive smoking - 105,311 min (n=1202) p=0,017, active smoking-119.1 l/min(n=885) p=0,108. PINF is important investigative tool thanks which we can: to differentiate in dependence the functional state of nose from: put the recognition (the patients with allergic rhinitis, the bronchial asthma

  10. Does rhinoplasty improve nasal breathing?

    PubMed

    Xavier, Rui

    2010-08-01

    Rhinoplasty is a surgical procedure that aims to improve nasal aesthetics and nasal breathing. The aesthetic improvement of the nose is usually judged subjectively by the patient and the surgeon, but the degree of improvement of nasal obstruction is difficult to assess by clinical examination only. The measurement of peak nasal inspiratory flow (PNIF) is a reliable tool that has been shown to correlate with other objective methods of assessing nasal breathing and with patients' symptoms of nasal obstruction. Twenty-three consecutive patients undergoing rhinoplasty have been evaluated by measurement of PNIF before and after surgery. All but three patients had an increase in PNIF after surgery. The mean preoperative PNIF was 86.5 L/min and the mean postoperative PNIF was 123.0 L/min ( P < 0.001). Not surprisingly, the greatest improvement in PNIF was achieved when bilateral spreader grafts were used. This study suggests that rhinoplasty does improve nasal breathing. (c) Thieme Medical Publishers

  11. Responses of Six-Weeks Aquatic Exercise on the Autonomic Nervous System, Peak Nasal Inspiratory Flow and Lung Functions in Young Adults with Allergic Rhinitis.

    PubMed

    Janyacharoen, Taweesak; Kunbootsri, Narupon; Arayawichanon, Preeda; Chainansamit, Seksun; Sawanyawisuth, Kittisak

    2015-06-01

    Allergic rhinitis is a chronic respiratory disease. Sympathetic hypofunction is identified in all of the allergic rhinitis patients. Moreover, allergic rhinitis is associated with decreased peak nasal inspiratory flow (PNIF) and impaired lung functions. The aim of this study was to investigate effects of six-week of aquatic exercise on the autonomic nervous system function, PNIF and lung functions in allergic rhinitis patients. Twenty-six allergic rhinitis patients, 12 males and 14 females were recruited in this study. Subjects were diagnosed by a physician based on history, physical examination, and positive reaction to a skin prick test. Subjects were randomly assigned to two groups. The control allergic rhinitis group received education and maintained normal life. The aquatic group performed aquatic exercise for 30 minutes a day, three days a week for six weeks. Heart rate variability, PNIF and lung functions were measured at the beginning, after three weeks and six weeks. There were statistically significant increased low frequency normal units (LF n.u.), PNIF and showed decreased high frequency normal units (HF n.u.) at six weeks after aquatic exercise compared with the control group. Six weeks of aquatic exercise could increase sympathetic activity and PNIF in allergic rhinitis patients.

  12. Characterization of deposition from nasal spray devices using a computational fluid dynamics model of the human nasal passages.

    PubMed

    Kimbell, Julia S; Segal, Rebecca A; Asgharian, Bahman; Wong, Brian A; Schroeter, Jeffry D; Southall, Jeremy P; Dickens, Colin J; Brace, Geoff; Miller, Frederick J

    2007-01-01

    Many studies suggest limited effectiveness of spray devices for nasal drug delivery due primarily to high deposition and clearance at the front of the nose. Here, nasal spray behavior was studied using experimental measurements and a computational fluid dynamics model of the human nasal passages constructed from magnetic resonance imaging scans of a healthy adult male. Eighteen commercially available nasal sprays were analyzed for spray characteristics using laser diffraction, high-speed video, and high-speed spark photography. Steadystate, inspiratory airflow (15 L/min) and particle transport were simulated under measured spray conditions. Simulated deposition efficiency and spray behavior were consistent with previous experimental studies, two of which used nasal replica molds based on this nasal geometry. Deposition fractions (numbers of deposited particles divided by the number released) of 20- and 50-microm particles exceeded 90% in the anterior part of the nose for most simulated conditions. Predicted particle penetration past the nasal valve improved when (1) the smaller of two particle sizes or the lower of two spray velocities was used, (2) the simulated nozzle was positioned 1.0 rather than 0.5 or 1.5 cm into the nostril, and (3) inspiratory airflow was present rather than absent. Simulations also predicted that delaying the appearance of normal inspiratory airflow more than 1 sec after the release of particles produced results equivalent to cases in which no inspiratory airflow was present. These predictions contribute to more effective design of drug delivery devices through a better understanding of the effects of nasal airflow and spray characteristics on particle transport in the nose.

  13. Multiparametric Analysis of Sniff Nasal Inspiratory Pressure Test in Middle Stage Amyotrophic Lateral Sclerosis.

    PubMed

    Sarmento, Antonio; Aliverti, Andrea; Marques, Layana; Pennati, Francesca; Dourado-Júnior, Mario Emílio; Fregonezi, Guilherme; Resqueti, Vanessa

    2018-01-01

    The relaxation rates and contractile properties of inspiratory muscles are altered with inspiratory muscle weakness and fatigue. This fact plays an important role in neuromuscular disorders patients and had never been extensively studied in amyotrophic lateral sclerosis (ALS). In this cross-sectional study, these parameters were investigated non-invasively through nasal inspiratory sniff pressure test (SNIP) in 39 middle stage spinal onset ALS subjects and compared with 39 healthy controls. ALS patients were also divided into three subgroups according to a decline in their percentage of predicted forced vital capacity (FVC %pred ) as well as a decline in the ALS functional rating scale score and its respiratory subscore (R-subscore) in order to determine the best parameter linked to early respiratory muscle weakness. When compared with healthy subjects, middle stage ALS subjects exhibited a significantly lower ( p  < 0.0001) maximum relaxation rate and maximum rate of pressure development (MRPD), as well as a significantly higher ( p  < 0.0001) tau (τ), contraction time, and half-relaxation time. The results from receiver operating characteristic curves showed that MRPD (AUC 0.735, p  < 0.001) and FVC %pred (AUC 0.749, p  = 0.009) were the best discriminator parameters between ALS patients with ≤30 and >30 points in the ALS functional rating scale. In addition, 1/2RT (AUC 0.720, p  = 0.01), FVC %pred (AUC 0.700, p  = 0.03), τ (AUC 0.824, p  < 0.0001), and MRPD (AUC 0.721, p  = 0.01) were the parameters more sensitive in detecting a fall of three points in the R-subscore. On the other hand, MRPD (AUC 0.781, p  < 0.001), τ (AUC 0.794, p  = 0.0001), and percentage of predicted of SNIP (AUC 0.769, p  = 0.002) were the parameters able to detect a fall in 30% of the FVC %pred in middle stage ALS patients. The contractile properties and relaxation rates of the diaphragm are altered in middle stage spinal onset ALS when

  14. Diagnostic strategies in nasal congestion

    PubMed Central

    Krouse, John; Lund, Valerie; Fokkens, Wytske; Meltzer, Eli O

    2010-01-01

    Nasal congestion is a major symptom of upper respiratory tract disorders, and its characterization an important part of the diagnosis of these illnesses. Patient history and assessment of nasal symptoms are essential components of diagnosis, providing an initial evaluation that may be adequate to rule out serious conditions. However, current congestion medications are not always fully effective. Thus, if symptoms do not respond adequately to therapy, or symptoms suggestive of more serious conditions are present, specialized assessments may be needed. Various techniques are available for diagnosing patients, including those used chiefly by primary care clinicians and those requiring the expertise of otolaryngologists, allergists, and other specialists. Endoscopy remains a mainstay for evaluating nasal blockage and its causes, while modalities such as peak nasal inspiratory flow and acoustic rhinometry are evolving to provide easy-to-use, noninvasive procedures that are sensitive enough to measure small but clinically important abnormalities and therapeutic changes. Several imaging modalities are available to the specialist for severe or unusual cases, as are specialized diagnostic procedures that measure adjunctive features of congestion, such as impaired mucociliary function. PMID:20463824

  15. Effort of breathing in children receiving high-flow nasal cannula.

    PubMed

    Rubin, Sarah; Ghuman, Anoopindar; Deakers, Timothy; Khemani, Robinder; Ross, Patrick; Newth, Christopher J

    2014-01-01

    High-flow humidified nasal cannula is often used to provide noninvasive respiratory support in children. The effect of high-flow humidified nasal cannula on effort of breathing in children has not been objectively studied, and the mechanism by which respiratory support is provided remains unclear. This study uses an objective measure of effort of breathing (Pressure. Rate Product) to evaluate high-flow humidified nasal cannula in critically ill children. Prospective cohort study. Quaternary care free-standing academic children's hospital. ICU patients younger than 18 years receiving high-flow humidified nasal cannula or whom the medical team planned to extubate to high-flow humidified nasal cannula within 72 hours of enrollment. An esophageal pressure monitoring catheter was placed to measure pleural pressures via a Bicore CP-100 pulmonary mechanics monitor. Change in pleural pressure (ΔPes) and respiratory rate were measured on high-flow humidified nasal cannula at 2, 5, and 8 L/min. ΔPes and respiratory rate were multiplied to generate the Pressure.Rate Product, a well-established objective measure of effort of breathing. Baseline Pes, defined as pleural pressure at end exhalation during tidal breathing, reflected the positive pressure generated on each level of respiratory support. Twenty-five patients had measurements on high-flow humidified nasal cannula. Median age was 6.5 months (interquartile range, 1.3-15.5 mo). Median Pressure,Rate Product was lower on high-flow humidified nasal cannula 8 L/min (median, 329 cm H2O·min; interquartile range, 195-402) compared with high-flow humidified nasal cannula 5 L/min (median, 341; interquartile range, 232-475; p = 0.007) or high-flow humidified nasal cannula 2 L/min (median, 421; interquartile range, 233-621; p < 0.0001) and was lower on high-flow humidified nasal cannula 5 L/min compared with high-flow humidified nasal cannula 2 L/min (p = 0.01). Baseline Pes was higher on high-flow humidified nasal

  16. The new agreement of the international RIGA consensus conference on nasal airway function tests.

    PubMed

    Vogt, K; Bachmann-Harildstad, G; Lintermann, A; Nechyporenko, A; Peters, F; Wernecke, K D

    2018-01-21

    The report reflects an agreement based on the consensus conference of the International Standardization Committee on the Objective Assessment of the Nasal Airway in Riga, 2nd Nov. 2016. The aim of the conference was to address the existing nasal airway function tests and to take into account physical, mathematical and technical correctness as a base of international standardization as well as the requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices. Rhinomanometry, acoustic rhinometry, peak nasal inspiratory flow, Odiosoft-Rhino, optical rhinometry, 24-h measurements, computational fluid dynamics, nasometry and the mirrow test were evaluated for important diagnostic criteria, which are the precision of the equipment including calibration and the software applied; validity with sensitivity, specificity, positive and negative predictive values, reliability with intra-individual and inter-individual reproducibility and responsiveness in clinical studies. For rhinomanometry, the logarithmic effective resistance was set as the parameter of high diagnostic relevance. In acoustic rhinometry, the area of interest for the minimal cross-sectional area will need further standardization. Peak nasal inspiratory flow is a reproducible and fast test, which showed a high range of mean values in different studies. The state of the art with computational fluid dynamics for the simulation of the airway still depends on high performance computing hardware and will, after standardization of the software and both the software and hardware for imaging protocols, certainly deliver a better understanding of the nasal airway flux.

  17. Flow through the nasal cavity of the spiny dogfish, Squalus acanthias

    NASA Astrophysics Data System (ADS)

    Timm-Davis, L. L.; Fish, F. E.

    2015-12-01

    The nasal cavity of spiny dogfish is a blind capsule with no internal connection to the oral cavity. Water is envisioned to flow through the cavity in a smooth, continuous flow pattern; however, this assumption is based on previous descriptions of the morphology of the olfactory cavity. No experimentation on the flow through the internal nasal cavity has been reported. Morphology of the head of the spiny dogfish ( Squalus acanthias) does not suggest a close external connection between the oral and nasal systems. However, dye visualization showed that there was flow through the nasal apparatus and from the excurrent nostril to the mouth when respiratory flows were simulated. The hydrodynamic flow through the nasal cavity was observed from flow tank experiments. The dorsum of the nasal cavity of shark heads from dead animals was exposed by dissection and a glass plate was glued over of the exposed cavity. When the head was placed in a flow, dye was observed to be drawn passively into the cavity showing a complex, three-dimensional hydrodynamic flow. Dye entered the incurrent nostril, flowed through the nasal lamellae, crossed over and under the nasal valve, and circulated around the nasal valve before exiting the excurrent nostril. When the nasal valve was removed, the dye became stagnant and back flowed out through the incurrent nostril. The single nasal valve has a hydrodynamic function that organizes a coherent flow of water through the cavity without disruption. The results suggest that the morphology of the nasal apparatus in concert with respiratory flow and ambient flows from active swimming can be used to draw water through the olfactory cavity of the shark.

  18. Humidification performance of two high-flow nasal cannula devices: a bench study.

    PubMed

    Chikata, Yusuke; Izawa, Masayo; Okuda, Nao; Itagaki, Taiga; Nakataki, Emiko; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2014-08-01

    Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. We evaluated 2 HFNC (Airvo 2 and Optiflow system) devices. Each HFNC was connected to simulated external nares using the manufacturer's standard circuit. The Airvo 2 outlet-chamber temperature was set at 37°C. The Optiflow system incorporated an O2/air blender and a heated humidifier, which was set at 40°C/3. For both systems, HFNC flow was tested at 20, 40, and 50 L/min. Simulating spontaneous breathing using a mechanical ventilator and TTL test lung, we tested tidal volumes (VT) of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. The TTL was connected to the simulated external nares with a standard ventilator circuit. To prevent condensation, the circuit was placed in an incubator maintained at 37°C. Small, medium, and large nasal prongs were tested. Absolute humidity (AH) of inspired gas was measured at the simulated external nares. At 20, 40, and 50 L/min of flow, respective AH values for the Airvo 2 were 35.3 ± 2.0, 37.1 ± 2.2, and 37.6 ± 2.1 mg/L, and for the Optiflow system, 33.1 ± 1.5, 35.9 ± 1.7, and 36.2 ± 1.8 mg/L. AH was lower at 20 L/min of HFNC flow than at 40 and 50 L/min (P < .01). While AH remained constant at 40 and 50 L/min, at 20 L/min of HFNC flow, AH decreased as VT increased for both devices. During bench use of HFNC, AH increased with increasing HFNC flow. When the inspiratory flow of spontaneous breathing exceeded the HFNC flow, AH was influenced by VT. At all experimental settings, AH remained > 30 mg/L.

  19. A placebo-controlled study of the nasal decongestant effect of phenylephrine and pseudoephedrine in the Vienna Challenge Chamber.

    PubMed

    Horak, Friedrich; Zieglmayer, Petra; Zieglmayer, René; Lemell, Patrick; Yao, Ruji; Staudinger, Heribert; Danzig, Melvyn

    2009-02-01

    Studies on the efficacy of phenylephrine in the treatment of nasal congestion have yielded inconsistent results, notwithstanding its approval for this indication. To evaluate and compare the decongestant effect of a single dose of phenylephrine to placebo and pseudoephedrine in patients with seasonal allergic rhinitis. This randomized, placebo-controlled, 3-way crossover study evaluated patient-scored nasal congestion, peak nasal inspiratory flow, and rhinomanometry at more than 6 hours in 39 grass-sensitive patients exposed to grass pollen in the Vienna Challenge Chamber. Patients were dosed with immediate-release formulations of phenylephrine, 12 mg, pseudoephedrine, 60 mg, as a control, or placebo. Phenylephrine was not significantly different from placebo in the primary end point, mean change in nasal congestion score at more than 6 hours (P = .56), whereas pseudoephedrine was significantly more effective than both placebo (P < .01) and phenylephrine (P = .01). Phase 1 results showed a difference between phenylephrine and placebo that was 64% of the difference between pseudoephedrine and placebo, substantially greater than the 17% difference observed for all phases. Carryover bias due to patient recall of the pseudoephedrine effect may have influenced these results. Rhinomanometry and peak nasal inspiratory flow results were consistent with these data. Neither phenylephrine nor pseudoephedrine had an effect on the nonnasal symptoms. No adverse events were reported in this study. During a 6-hour observation period, a single dose of pseudoephedrine but not phenylephrine resulted in significant improvement in measures of nasal congestion. Neither phenylephrine nor pseudoephedrine had an effect on nonnasal symptoms.

  20. The effects of flow on airway pressure during nasal high-flow oxygen therapy.

    PubMed

    Parke, Rachael L; Eccleston, Michelle L; McGuinness, Shay P

    2011-08-01

    Nasal high-flow oxygen therapy increases the mean nasopharyngeal airway pressure in adults, but the relationship between flow and pressure is not well defined. To determine the relationship between flow and pressure with the Optiflow nasal high-flow oxygen therapy system. We invited patients scheduled for elective cardiac surgery to participate. Measurements were performed with nasal high-flow oxygen at flows of 30, 40, and 50 L/min, with the patient's mouth both open and closed. Pressures were recorded over one minute of breathing, and average flows were calculated via simple averaging. With the mouth closed, the mean ± SD airway pressures at 30, 40, and 50 L/min were 1.93 ± 1.25 cm H(2)O, 2.58 ± 1.54 cm H(2)O, and 3.31 ± 1.05 cm H(2)O, respectively. There was a positive linear relationship between flow and pressure. The mean nasopharyngeal pressure during nasal high-flow oxygen increases as flow increases. Australian Clinical Trials Registry http://www.adhb.govt.nz/achicu/hot_2_airway_pressure.htm.

  1. Unsteady flow in the nasal cavity with high flow therapy measured by stereoscopic PIV

    NASA Astrophysics Data System (ADS)

    Spence, C. J. T.; Buchmann, N. A.; Jermy, M. C.

    2012-03-01

    Nasal high flow (NHF) cannulae are used to deliver heated and humidified air to patients at steady flows ranging from 5 to 50 l/min. In this study, the flow velocities in the nasal cavity across the complete respiratory cycle during natural breathing and with NHF has been mapped in vitro using time-resolved stereoscopic particle image velocimetry (SPIV). An anatomically accurate silicone resin model of a complete human nasal cavity was constructed using CT scan data and rapid prototyping. Physiological breathing waveforms were reproduced in vitro using Reynolds and Womersley number matching and a piston pump driven by a ball screw and stepper motor. The flow pattern in the nasal cavity with NHF was found to differ significantly from natural breathing. Velocities of 2.4 and 3.3 ms-1 occurred in the nasal valve during natural breathing at peak expiration and inspiration, respectively; however, on expiration, the maximum velocity of 3.8 ms-1 occurred in the nasopharynx. At a cannula flow rate of 30 l/min, maximal velocities of 13.6 and 16.5 ms-1 at peak expiration and inspiration, respectively, were both located in the cannula jet within the nasal valve. Results are presented that suggest the quasi-steady flow assumption is invalid in the nasal cavity during natural breathing; however, it was valid with NHF. Cannula flow has been found to continuously flush the nasopharyngeal dead space, which may enhance carbon dioxide removal and increase oxygen fraction.

  2. REDUCTION IN INSPIRATORY FLOW ATTENUATES IL-8 RELEASE AND MAPK ACTIVATION OF LUNG OVERSTRETCH

    EPA Science Inventory

    Lung overstretch involves mechanical factors, including large tidal volumes (VT), which induce inflammatory responses. The current authors hypothesised that inspiratory flow contributes to ventilator-induced inflammation. Buffer-perfused rabbit lungs were ventilated for 2 h with ...

  3. Effect of anatomy on human nasal air flow and odorant transport patterns: implications for olfaction.

    PubMed

    Zhao, Kai; Scherer, Peter W; Hajiloo, Shoreh A; Dalton, Pamela

    2004-06-01

    Recent studies that have compared CT or MRI images of an individual's nasal anatomy and measures of their olfactory sensitivity have found a correlation between specific anatomical areas and performance on olfactory assessments. Using computational fluid dynamics (CFD) techniques, we have developed a method to quickly (nasal CT scans from an individual patient into an anatomically accurate 3-D numerical nasal model that can be used to predict airflow and odorant transport, which may ultimately determine olfactory sensitivity. The 3-D model can be also be rapidly modified to depict various anatomical deviations, such as polyps and their removal, that may alter nasal airflow and impair olfactory ability. To evaluate the degree to which variations in critical nasal areas such as the olfactory slit and nasal valve can alter airflow and odorant transport, inspiratory and expiratory airflow with odorants were simulated using numerical finite volume methods. Results suggest that anatomical changes in the olfactory region (upper meatus below the cribriform plate) and the nasal valve region will strongly affect airflow patterns and odorant transport through the olfactory region, with subsequent effects on olfactory function. The ability to model odorant transport through individualized models of the nasal passages holds promise for relating anatomical deviations to generalized or selective disturbances in olfactory perception and may provide important guidance for treatments for nasal-sinus disease, occupational rhinitis and surgical interventions that seek to optimize airflow and improve deficient olfactory function.

  4. Reference values of inspiratory spirometry for Finnish adults.

    PubMed

    Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R

    2018-03-07

    Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.

  5. Humidification of inspired oxygen is increased with pre-nasal cannula, compared to intranasal cannula.

    PubMed

    Dellweg, Dominic; Wenze, Markus; Hoehn, Ekkehard; Bourgund, Olaf; Haidl, Peter

    2013-08-01

    Oxygen therapy is usually combined with a humidification device, to prevent mucosal dryness. Depending on the cannula design, oxygen can be administered pre- or intra-nasally (administration of oxygen in front of the nasal ostia vs cannula system inside the nasal vestibulum). The impact of cannula design on intra-nasal humidity, however, has not been investigated to date. First, to develop a system, that samples air from the nasal cavity and analyzes the humidity of these samples. Second, to investigate nasal humidity during pre-nasal and intra-nasal oxygen application, with and without humidification. We first developed and validated a sampling and analysis system to measure humidity from air samples. By means of this system we measured inspiratory air samples from 12 subjects who received nasal oxygen with an intra-nasal and pre-nasal cannula at different flows, with and without humidification. The sampling and analysis system showed good correlation to a standard hygrometer within the tested humidity range (r = 0.99, P < .001). In our subjects intranasal humidity dropped significantly, from 40.3 ± 8.7% to 35.3 ± 5.8%, 32 ± 5.6%, and 29.0 ± 6.8% at flows of 1, 2, and 3 L, respectively, when oxygen was given intra-nasally without humidification (P = .001, P < .001, and P < .001, respectively). We observed no significant change in airway humidity when oxygen was given pre-nasally without humidification. With the addition of humidification we observed no significant change in humidity at any flow, and independent of pre- or intranasal oxygen administration. Pre-nasal administration of dry oxygen achieves levels of intranasal humidity similar to those achieved by intranasal administration in combination with a bubble through humidifier. Pre-nasal oxygen simplifies application and may reduce therapy cost.

  6. Inspiratory flow rate, not type of incentive spirometry device, influences chest wall motion in healthy individuals.

    PubMed

    Chang, Angela T; Palmer, Kerry R; McNaught, Jessie; Thomas, Peter J

    2010-08-01

    This study investigated the effect of flow rates and spirometer type on chest wall motion in healthy individuals. Twenty-one healthy volunteers completed breathing trials to either two times tidal volume (2xV(T)) or inspiratory capacity (IC) at high, low, or natural flow rates, using a volume- or flow-oriented spirometer. The proportions of rib cage movement to tidal volume (%RC/V(T)), chest wall diameters, and perceived level of exertion (RPE) were compared. Low and natural flow rates resulted in significantly lower %RC/V(T) compared to high flow rate trials (p=0.001) at 2xV(T). Low flow trials also resulted in significantly less chest wall motion in the upper anteroposterior direction than high and natural flow rates (p<0.001). At IC, significantly greater movement occurred in the abdominal lateral direction during low flow compared to high and natural flow trials (both p<0.003). RPE was lower for the low flow trials compared to high flow trials at IC and 2xV(T) (p<0.01). In healthy individuals, inspiratory flow (not device type) during incentive spirometry determines the resultant breathing pattern. High flow rates result in greater chest wall motion than low flow rates.

  7. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.

    PubMed

    Yu, Chun-Hsiang; Su, Po-Lan; Lin, Wei-Chieh; Lin, Sheng-Hsiang; Chen, Chang-Wen

    2015-02-01

    Late inspiratory rise in airway pressure (LIRAP, Paw/ΔT) caused by inspiratory muscle relaxation or expiratory muscle contraction is frequently seen during pressure support ventilation (PSV), although the modulating factors are unknown. We investigated the effects of respiratory mechanics (normal, obstructive, restrictive, or mixed), inspiratory effort (-2, -8, or -15 cm H2O), flow cycle criteria (5-40% peak inspiratory flow), and duration of inspiratory muscle relaxation (0.18-0.3 s) on LIRAP during PSV using a lung simulator and 4 types of ventilators. LIRAP occurred with all lung models when inspiratory effort was medium to high and duration of inspiratory muscle relaxation was short. The normal lung model was associated with the fastest LIRAP, whereas the obstructive lung model was associated with the slowest. Unless lung mechanics were normal or mixed, LIRAP was unlikely to occur when inspiratory effort was low. Different ventilators were also associated with differences in LIRAP speed. Except for within the restrictive lung model, changes in flow cycle level did not abolish LIRAP if inspiratory effort was medium to high. Increased duration of inspiratory relaxation also led to the elimination of LIRAP. Simulation of expiratory muscle contraction revealed that LIRAP occurred only when expiratory muscle contraction occurred sometime after the beginning of inspiration. Our simulation study reveals that both respiratory resistance and compliance may affect LIRAP. Except for under restrictive lung conditions, LIRAP is unlikely to be abolished by simply lowering flow cycle criteria when inspiratory effort is strong and relaxation time is rapid. LIRAP may be caused by expiratory muscle contraction when it occurs during inspiration. Copyright © 2015 by Daedalus Enterprises.

  8. Effect of acute inspiratory muscle exercise on blood flow of resting and exercising limbs and glucose levels in type 2 diabetes.

    PubMed

    Corrêa, Ana Paula dos Santos; Antunes, Cristiano Fetter; Figueira, Franciele Ramos; de Castro, Marina Axmann; Ribeiro, Jorge Pinto; Schaan, Beatriz D'Agord

    2015-01-01

    To evaluate the effects of inspiratory loading on blood flow of resting and exercising limbs in patients with diabetic autonomic neuropathy. Ten diabetic patients without cardiovascular autonomic neuropathy (DM), 10 patients with cardiovascular autonomic neuropathy (DM-CAN) and 10 healthy controls (C) were randomly assigned to inspiratory muscle load of 60% or 2% of maximal inspiratory pressure (PImax) for approximately 5 min, while resting calf blood flow (CBF) and exercising forearm blood flow (FBF) were measured. Reactive hyperemia was also evaluated. From the 20 diabetic patients initially allocated, 6 wore a continuous glucose monitoring system to evaluate the glucose levels during these two sessions (2%, placebo or 60%, inspiratory muscle metaboreflex). Mean age was 58 ± 8 years, and mean HbA1c, 7.8% (62 mmol/mol) (DM and DM-CAN). A PImax of 60% caused reduction of CBF in DM-CAN and DM (P<0.001), but not in C, whereas calf vascular resistance (CVR) increased in DM-CAN and DM (P<0.001), but not in C. The increase in FBF during forearm exercise was blunted during 60% of PImax in DM-CAN and DM, and augmented in C (P<0.001). Glucose levels decreased by 40 ± 18.8% (P<0.001) at 60%, but not at 2%, of PImax. A negative correlation was observed between reactive hyperemia and changes in CVR (Beta coefficient = -0.44, P = 0.034). Inspiratory muscle loading caused an exacerbation of the inspiratory muscle metaboreflex in patients with diabetes, regardless of the presence of neuropathy, but influenced by endothelial dysfunction. High-intensity exercise that recruits the diaphragm can abruptly reduce glucose levels.

  9. Humidity and Inspired Oxygen Concentration During High-Flow Nasal Cannula Therapy in Neonatal and Infant Lung Models.

    PubMed

    Chikata, Yusuke; Ohnishi, Saki; Nishimura, Masaji

    2017-05-01

    High-flow nasal cannula therapy (HFNC) for neonate/infants can deliver up to 10 L/min of heated and humidified gas, and F IO 2 can be adjusted to between 0.21 and 1.0. With adults, humidification and actual F IO 2 are known to vary according to inspiratory and HFNC gas flow, tidal volume (V T ), and ambient temperature. There have been few studies focused on humidification and F IO 2 in HFNC settings for neonates/infants, so we performed a bench study to investigate the influence of gas flow, ambient temperature, and respiratory parameters on humidification and actual F IO 2 in a neonate/infant simulation. HFNC gas flow was set at 3, 5, and 7 L/min, and F IO 2 was set at 0.3, 0.5, and 0.7. Spontaneous breathing was simulated using a 2-bellows-in-a-box model of a neonate lung. Tests were conducted with V T settings of 20, 30, and 40 mL and breathing frequencies of 20 and 30 breaths/min. Inspiratory time was 0.8 s with decelerating flow waveform. The HFNC tube was placed in an incubator, which was either set at 37°C or turned off. Absolute humidity (AH) and actual F IO 2 were measured for 1 min using a hygrometer and an oxygen analyzer, and data for the final 3 breaths were extracted. At all settings, when the incubator was turned on, AH was greater than when it was turned off ( P < .001). When the incubator was turned off, as gas flow increased, AH increased ( P < .001); however, V T did not affect AH ( P = .16). As gas flow increased, actual F IO 2 more closely corresponded to set F IO 2 . When gas flow was 3 L/min, measured F IO 2 decreased proportionally more at each F IO 2 setting increment ( P < .001). AH was affected by ambient temperature and HFNC gas flow. Actual F IO 2 depended on V T when gas flow was 3 L/min. Copyright © 2017 by Daedalus Enterprises.

  10. Modeling the pharyngeal pressure during adult nasal high flow therapy.

    PubMed

    Kumar, Haribalan; Spence, Callum J T; Tawhai, Merryn H

    2015-12-01

    Subjects receiving nasal high flow (NHF) via wide-bore nasal cannula may experience different levels of positive pressure depending on the individual response to NHF. In this study, airflow in the nasal airway during NHF-assisted breathing is simulated and nasopharyngeal airway pressure numerically computed, to determine whether the relationship between NHF and pressure can be described by a simple equation. Two geometric models are used for analysis. In the first, 3D airway geometry is reconstructed from computed tomography images of an adult nasal airway. For the second, a simplified geometric model is derived that has the same cross-sectional area as the complex model, but is more readily amenable to analysis. Peak airway pressure is correlated as a function of nasal valve area, nostril area and cannula flow rate, for NHF rates of 20, 40 and 60 L/min. Results show that airway pressure is related by a power law to NHF rate, valve area, and nostril area. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. External nasal dilators: definition, background, and current uses

    PubMed Central

    Dinardi, Ricardo Reis; de Andrade, Cláudia Ribeiro; Ibiapina, Cássio da Cunha

    2014-01-01

    Our goal was to revise the literature about external nasal dilators (ENDs) as to their definition, history, and current uses. We reviewed journals in the PubMed and MEDLINE databases. The current uses hereby presented and discussed are physical exercise, nasal congestion and sleep, snoring, pregnancy, cancer, and healthy individuals. Numerous studies have shown that ENDs increase the cross-sectional area of the nasal valve, reducing nasal resistance and transnasal inspiratory pressure and stabilizing the lateral nasal vestibule, avoiding its collapse during final inspiration. These effects also facilitate breathing and are beneficial to patients with nasal obstruction. Furthermore, END use is simple, noninvasive, painless, affordable, and bears minimum risk to the user. Most studies have limited sample size and are mainly focused on physical exercise. In conclusion, ENDs seem useful, so further studies involving potential effects on the performance of physical tests and improvements in sleep quality are necessary, especially in children and teenagers. PMID:25419156

  12. Changes in nasal airflow and heat transfer correlate with symptom improvement after surgery for nasal obstruction.

    PubMed

    Kimbell, J S; Frank, D O; Laud, Purushottam; Garcia, G J M; Rhee, J S

    2013-10-18

    Surgeries to correct nasal airway obstruction (NAO) often have less than desirable outcomes, partly due to the absence of an objective tool to select the most appropriate surgical approach for each patient. Computational fluid dynamics (CFD) models can be used to investigate nasal airflow, but variables need to be identified that can detect surgical changes and correlate with patient symptoms. CFD models were constructed from pre- and post-surgery computed tomography scans for 10 NAO patients showing no evidence of nasal cycling. Steady-state inspiratory airflow, nasal resistance, wall shear stress, and heat flux were computed for the main nasal cavity from nostrils to posterior nasal septum both bilaterally and unilaterally. Paired t-tests indicated that all CFD variables were significantly changed by surgery when calculated on the most obstructed side, and that airflow, nasal resistance, and heat flux were significantly changed bilaterally as well. Moderate linear correlations with patient-reported symptoms were found for airflow, heat flux, unilateral allocation of airflow, and unilateral nasal resistance as a fraction of bilateral nasal resistance when calculated on the most obstructed nasal side, suggesting that these variables may be useful for evaluating the efficacy of nasal surgery objectively. Similarity in the strengths of these correlations suggests that patient-reported symptoms may represent a constellation of effects and that these variables should be tracked concurrently during future virtual surgery planning. © 2013 Elsevier Ltd. All rights reserved.

  13. Estimation of Pharyngeal Collapsibility During Sleep by Peak Inspiratory Airflow.

    PubMed

    Azarbarzin, Ali; Sands, Scott A; Taranto-Montemurro, Luigi; Oliveira Marques, Melania D; Genta, Pedro R; Edwards, Bradley A; Butler, James; White, David P; Wellman, Andrew

    2017-01-01

    Pharyngeal critical closing pressure (Pcrit) or collapsibility is a major determinant of obstructive sleep apnea (OSA) and may be used to predict the success/failure of non-continuous positive airway pressure (CPAP) therapies. Since its assessment involves overnight manipulation of CPAP, we sought to validate the peak inspiratory flow during natural sleep (without CPAP) as a simple surrogate measurement of collapsibility. Fourteen patients with OSA attended overnight polysomnography with pneumotachograph airflow. The middle third of the night (non-rapid eye movement sleep [NREM]) was dedicated to assessing Pcrit in passive and active states via abrupt and gradual CPAP pressure drops, respectively. Pcrit is the extrapolated CPAP pressure at which flow is zero. Peak and mid-inspiratory flow off CPAP was obtained from all breaths during sleep (excluding arousal) and compared with Pcrit. Active Pcrit, measured during NREM sleep, was strongly correlated with both peak and mid-inspiratory flow during NREM sleep (r = -0.71, p < .005 and r = -0.64, p < .05, respectively), indicating that active pharyngeal collapsibility can be reliably estimated from simple airflow measurements during polysomnography. However, there was no significant relationship between passive Pcrit, measured during NREM sleep, and peak or mid-inspiratory flow obtained from NREM sleep. Flow measurements during REM sleep were not significantly associated with active or passive Pcrit. Our study demonstrates the feasibility of estimating active Pcrit using flow measurements in patients with OSA. This method may enable clinicians to estimate pharyngeal collapsibility without sophisticated equipment and potentially aid in the selection of patients for non- positive airway pressure therapies. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  14. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    PubMed

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P < 0.001], with parallel changes in QPA Neither PEEP nor volume state altered RVR (P = 0.489). MSFPinsp_hold overestimated MSFPRAO [16.5 (SD 5.8) vs. 13.6 (SD 3.2) mmHg, P = 0.001; mean difference 3.0 (SD 5.1) mmHg]. Inspiratory holds shifted the RAP/QPA relationship rightward in euvolemia because inferior vena cava flow (QIVC) recovered early after an inspiratory hold nadir. The QIVC nadir was lowest after bleeding [36% (SD 24%) of preinspiratory hold at 15 cmH2O inspiratory pressure], and the QIVC recovery was most complete at the lowest inspiratory pressures independent of volume state [range from 80% (SD 7%) after bleeding to 103% (SD 8%) at PEEP 10 cmH2O of QIVC before inspiratory hold]. The QIVC recovery thus defends venous return, possibly via hepatosplanchnic vascular waterfall. Copyright © 2016 the American Physiological Society.

  15. Effect of Nasal Obstruction on Continuous Positive Airway Pressure Treatment: Computational Fluid Dynamics Analyses

    PubMed Central

    Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi

    2016-01-01

    Objective Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. Methods We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject’s CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Results Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. Conclusion This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow

  16. Nasal versus oronasal raised volume forced expirations in infants – A real physiologic challenge

    PubMed Central

    Morris, Mohy G.

    2012-01-01

    Summary Raised volume rapid thoracoabdominal compression (RTC) generates forced expiration (FE) in infants typically from an airway opening pressure of 30 cm H2O (V30). We hypothesized that the higher nasal than pulmonary airway resistance limits forced expiratory flows (FEF%) during (nasal) FEn, which an opened mouth, (oronasal) FEo, would resolve. Measurements were performed during a brief post-hyperventilation apnea on twelve healthy infants aged 6.9–104 weeks. In two infants, forced expiratory (FEFV) flow volume (FV) curves were generated using a facemask that covered the nose and a closed mouth, then again with a larger mask with the mouth opened. In other infants (n=10), the mouth closed spontaneously during FE. Oronasal passive expiration from V30 generated either the inspiratory capacity (IC) or by activating RTC before end-expiration, the slow vital capacity (jSVC). Peak flow (PF), FEF25, FEF50, FEF25–75, FEV0.4 and FEV0.5 were lower via FEn than FEo (p<0.05), but the ratio of expired volume at PF and forced vital capacity (FVC) as percent was higher (p<0.05). FEF75, FEF85, FEF90, FVC as well as the applied jacket pressures were not different (p>0.05). FEFV curves generated via FEo exhibited higher PF than FV curves of IC (p< 0.05); PF of those produced via FEn were not different from FV curves of IC (p> 0.05) but lower than those of jSVC (p< 0.05). In conclusion, the higher nasal than pulmonary airways resistance unequivocally affects the FEFV curves by consistently reducing PF and decreases mid-expiratory flows. A monitored slightly opened mouth and a gentle anterior jaw thrust are physiologically integral for raised volume RTC in order to maximize the oral and minimize nasal airways contribution to FE so that flow limitation would be in the pulmonary not nasal airways. PMID:22328241

  17. Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals

    PubMed Central

    Bailey, Ryan S.; Casey, Kevin P.; Pawar, Sachin S.; Garcia, Guilherme J. M.

    2016-01-01

    Importance Historically, otolaryngologists have focused on nasal resistance to airflow and minimum airspace cross-sectional area as objective measures of nasal obstruction using methods such as rhinomanometry and acoustic rhinometry. However, subjective sensation of nasal patency may be more associated with activation of cold receptors by inspired air than with respiratory effort. Objective To investigate whether subjective nasal patency correlates with nasal mucosal temperature in healthy subjects. Design, Setting, and Participants Twenty-two healthy adults were recruited for this study. Subjects first completed the Nasal Obstruction Symptom Evaluation (NOSE) and a unilateral visual analog scale (VAS) to quantify subjective nasal patency. A miniaturized thermocouple sensor was then used to record nasal mucosal temperature bilaterally in two locations along the nasal septum: at the vestibule and across from the inferior turbinate head. Results The range of temperature oscillations during the breathing cycle, defined as the difference between end-expiratory and end-inspiratory temperatures, was greater during deep breaths (ΔTexp-insp = 6.2 ± 2.6°C) than during resting breathing (ΔTexp-insp = 4.2 ± 2.3°C) in both locations (p < 10−13). Mucosal temperature measured at the right vestibule had a statistically significant correlation with both right-side VAS score (Pearson r = −0.55, p=0.0076) and NOSE score (Pearson r = −0.47, p=0.028). No other statistically significant correlations were found between mucosal temperature and subjective nasal patency scores. Nasal mucosal temperature was lower in the first cavity to be measured, which was the right cavity in all subjects. Conclusions and Relevance The greater mucosal temperature oscillations during deep breathing is consistent with the common experience that airflow sensation is enhanced during deep breaths, thus supporting the hypothesis that mucosal cooling plays a central role in nasal airflow sensation

  18. Effector cell signature in peripheral blood following nasal allergen challenge in grass pollen allergic individuals.

    PubMed

    Shamji, M H; Bellido, V; Scadding, G W; Layhadi, J A; Cheung, D K M; Calderon, M A; Asare, A; Gao, Z; Turka, L A; Tchao, N; Togias, A; Phippard, D; Durham, S R

    2015-02-01

    Several studies have demonstrated the time course of inflammatory mediators in nasal fluids following nasal allergen challenge (NAC), whereas the effects of NAC on cells in the periphery are unknown. We examined the time course of effector cell markers (for basophils, dendritic cells and T cells) in peripheral blood after nasal grass pollen allergen challenge. Twelve participants with seasonal allergic rhinitis underwent a control (diluent) challenge followed by NAC after an interval of 14 days. Nasal symptoms and peak nasal inspiratory flow (PNIF) were recorded along with peripheral basophil, T-cell and dendritic cell responses (flow cytometry), T-cell proliferative responses (thymidine incorporation), and cytokine expression (FluoroSpot assay). Robust increases in nasal symptoms and decreases in PNIF were observed during the early (0-1 h) response and modest significant changes during the late (1-24 h) response. Sequential peaks in peripheral blood basophil activation markers were observed (CD107a at 3 h, CD63 at 6 h, and CD203c(bright) at 24 h). T effector/memory cells (CD4(+) CD25(lo) ) were increased at 6 h and accompanied by increases in CD80(+) and CD86(+) plasmacytoid dendritic cells (pDCs). Ex vivo grass antigen-driven T-cell proliferative responses and the frequency of IL-4(+) CD4(+) T cells were significantly increased at 6 h after NAC when compared to the control day. Basophil, T-cell, and dendritic cell activation increased the frequency of allergen-driven IL-4(+) CD4(+) T cells, and T-cell proliferative responses are detectable in the periphery after NAC. These data confirm systemic cellular activation following a local nasal provocation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. CONTRIBUTION OF INSPIRATORY FLOW TO ACTIVATION OF EGFR, RAS, MAPK, ATF-2 AND C-JUN DURING LUNG STRETCH

    EPA Science Inventory

    Contribution of Inspiratory Flow to Activation of EGFR, Ras, MAPK, ATF-2 and c-Jun during Lung Stretch

    R. Silbajoris 1, Z. Li 2, J. M. Samet 1 and Y. C. Huang 1. 1 NHEERL, ORD, US EPA, RTP, NC and 2 CEMALB, UNC-CH, Chapel Hill, NC .

    Mechanical ventilation with larg...

  20. Nasal high flow clears anatomical dead space in upper airway models

    PubMed Central

    Celik, Gülnaz; Feng, Sheng; Bartenstein, Peter; Meyer, Gabriele; Eickelberg, Oliver; Schmid, Otmar; Tatkov, Stanislav

    2015-01-01

    Recent studies showed that nasal high flow (NHF) with or without supplemental oxygen can assist ventilation of patients with chronic respiratory and sleep disorders. The hypothesis of this study was to test whether NHF can clear dead space in two different models of the upper nasal airways. The first was a simple tube model consisting of a nozzle to simulate the nasal valve area, connected to a cylindrical tube to simulate the nasal cavity. The second was a more complex anatomically representative upper airway model, constructed from segmented CT-scan images of a healthy volunteer. After filling the models with tracer gases, NHF was delivered at rates of 15, 30, and 45 l/min. The tracer gas clearance was determined using dynamic infrared CO2 spectroscopy and 81mKr-gas radioactive gamma camera imaging. There was a similar tracer-gas clearance characteristic in the tube model and the upper airway model: clearance half-times were below 1.0 s and decreased with increasing NHF rates. For both models, the anterior compartments demonstrated faster clearance levels (half-times < 0.5 s) and the posterior sections showed slower clearance (half-times < 1.0 s). Both imaging methods showed similar flow-dependent tracer-gas clearance in the models. For the anatomically based model, there was complete tracer-gas removal from the nasal cavities within 1.0 s. The level of clearance in the nasal cavities increased by 1.8 ml/s for every 1.0 l/min increase in the rate of NHF. The study has demonstrated the fast-occurring clearance of nasal cavities by NHF therapy, which is capable of reducing of dead space rebreathing. PMID:25882385

  1. Inspiratory muscle training increases inspiratory muscle strength in patients weaning from mechanical ventilation: a systematic review.

    PubMed

    Moodie, Lisa; Reeve, Julie; Elkins, Mark

    2011-01-01

    Does inspiratory muscle training improve inspiratory muscle strength and endurance, facilitate weaning, improve survival, and reduce the rate of reintubation and tracheostomy in adults receiving mechanical ventilation? Systematic review of randomised or quasi-randomised controlled trials. Adults over 16 years of age receiving mechanical ventilation. Inspiratory muscle training versus sham or no inspiratory muscle training. Data were extracted regarding inspiratory muscle strength and endurance, the duration of unassisted breathing periods, weaning success and duration, reintubation and tracheostomy, survival, adverse effects, and length of stay. Three studies involving 150 participants were included in the review. The studies varied in time to commencement of the training, the device used, the training protocol, and the outcomes measured. Inspiratory muscle training significantly increased inspiratory muscle strength over sham or no training (weighted mean difference 8 cmH(2)O, 95% CI 6 to 9). There were no statistically significant differences between the groups in weaning success or duration, survival, reintubation, or tracheostomy. Inspiratory muscle training was found to significantly increase inspiratory muscle strength in adults undergoing mechanical ventilation. Despite data from a substantial pooled cohort, it is not yet clear whether the increase in inspiratory muscle strength leads to a shorter duration of mechanical ventilation, improved weaning success, or improved survival. Further large randomised studies are required to clarify the impact of inspiratory muscle training on patients receiving mechanical ventilation. PROSPERO CRD42011001132. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.

  2. Heated, humidified high-flow nasal cannula therapy: yet another way to deliver continuous positive airway pressure?

    PubMed

    Kubicka, Zuzanna J; Limauro, Joseph; Darnall, Robert A

    2008-01-01

    The goal was to estimate the level of delivered continuous positive airway pressure by measuring oral cavity pressure with the mouth closed in infants of various weights and ages treated with heated, humidified high-flow nasal cannula at flow rates of 1-5 L/minute. We hypothesized that clinically relevant levels of continuous positive airway pressure would not be achieved if a nasal leak is maintained. After performing bench measurements and demonstrating that oral cavity pressure closely approximated levels of traditionally applied nasal continuous positive airway pressure, we successfully measured oral cavity pressure during heated, humidified, high-flow nasal cannula treatment in 27 infants. Small (outer diameter: 0.2 cm) cannulae were used for all infants, and flow rates were left as ordered by providers. Bench measurements showed that, for any given leak size, there was a nearly linear relationship between flow rate and pressure. The highest pressure achieved was 4.5 cmH2O (flow rate: 8 L/minute; leak: 3 mm). In our study infants (postmenstrual age: 29.1-44.7 weeks; weight: 835-3735 g; flow rate: 1-5 L/minute), no pressure was generated with the mouth open at any flow rate. With the mouth closed, the oral cavity pressure was related to both flow rate and weight. For infants of < or = 1500 g, there was a linear relationship between flow rate and oral cavity pressure. Oral cavity pressure can estimate the level of continuous positive airway pressure. Continuous positive airway pressure generated with heated, humidified, high-flow nasal cannula treatment depends on the flow rate and weight. Only in the smallest infants with the highest flow rates, with the mouth fully closed, can clinically significant but unpredictable levels of continuous positive airway pressure be achieved. We conclude that heated, humidified high-flow nasal cannula should not be used as a replacement for delivering continuous positive airway pressure.

  3. [Psychopathological characteristics in patients with deviation of nasal septum: a preliminary analysis].

    PubMed

    Li, W T; Chen, X Z; Tu, W J; Huang, Z Z; Chang, L H; Wang, J; Zhang, G H

    2016-09-07

    -90 ( Z =0.415, P =0.005, Z =0.445, P =0.002, respectively). The scores of SDS and SAS had positive correlation ( Z =0.392, P =0.008). The VAS score of nasal obstruction was 6.0±3.2. The rhinomanometry in inspiratory and expiratory phase were (0.202±0.140) kPa·S/cm 3 and (0.230±0.161) kPa·S/cm 3 . Besides the positive correlation between the rhinomanometry in inspiratory phase and SDS ( Z =0.332, P =0.045), the psychological scores, including SCL-90 score, depression, anxiety factors score, SAS and SDS, had no correlation with VAS scores and rhinomanometry ( r value was -0.030, -0.052, -0.026, 0.107, 0.185, 0.066, 0.160, 0.203, respectively, all P >0.05). Conclusions: High prevalence of depression and anxiety is found in patients with deviation of nasal septum. The SCL-90 score is consistent with SDS and SAS. Besides the positive correlation between the rhinomanometry in inspiratory phase and SDS, the psychological scores (SCL-90 score, depression, anxiety factors score, SAS and SDS) have no correlation with VAS score and rhinomanometry.

  4. Inspiratory and expiratory aerosol deposition in the upper airway.

    PubMed

    Verbanck, S; Kalsi, H S; Biddiscombe, M F; Agnihotri, V; Belkassem, B; Lacor, C; Usmani, O S

    2011-02-01

    Aerosol deposition efficiency (DE) in the extrathoracic airways during mouth breathing is currently documented only for the inspiratory phase of respiration, and there is a need for quantification of expiratory DE. Our aim was to study both inspiratory and expiratory DE in a realistic upper airway geometry. This was done experimentally on a physical upper airway cast by scintigraphy, and numerically by computational fluid dynamic simulations using a Reynolds Averaged Navier?Stokes (RANS) method with a k-? SST turbulence model coupled with a stochastic Lagrangian approach. Experiments and simulations were carried out for particle sizes (3 and 6 μm) and flow rates (30 and 60 L/min) spanning the ranges of Stokes (Stk) and Reynolds (Re) number pertinent to therapeutic and environmental aerosols. We showed that inspiratory total deposition data obtained by scintigraphy fell onto a previously published deposition curve representative of a range of upper airway geometries. We also found that expiratory and inspiratory DE curves were almost identical. Finally, DE in different compartments of the upper airway model showed a very different distribution pattern of aerosol deposition during inspiration and expiration, with preferential deposition in oral and pharyngeal compartments, respectively. These compartmental deposition patterns were very consistent and only slightly dependent on particle size or flow rate. Total deposition for inspiration and expiration was reasonably well-mimicked by the RANS simulation method we employed, and more convincingly so in the upper range of the Stk and Re number. However, compartmental deposition patterns showed discrepancies between experiments and RANS simulations, particularly during expiration.

  5. Optimal arrangement of magnetic coils for functional magnetic stimulation of the inspiratory muscles in dogs.

    PubMed

    Lin, Vernon Weh-Hau; Zhu, Ercheng; Sasse, Scott A; Sassoon, Catherine; Hsiao, Ian N

    2005-12-01

    In an attempt to maximize inspiratory pressure and volume, the optimal position of a single or of dual magnetic coils during functional magnetic stimulation (FMS) of the inspiratory muscles was evaluated in twenty-three dogs. Unilateral phrenic magnetic stimulation (UPMS) or bilateral phrenic magnetic stimulation (BPMS), posterior cervical magnetic stimulation (PCMS), anterior cervical magnetic stimulation (ACMS) as well as a combination of PCMS and ACMS were performed. Trans-diaphragmatic pressure (Pdi), flow, and lung volume changes with an open airway were measured. Transdiaphragmatic pressure was also measured with an occluded airway. Changes in inspiratory parameters during FMS were compared with 1) electrical stimulation of surgically exposed bilateral phrenic nerves (BPES) and 2) ventral root electrical stimulation at C5-C7 (VRES C5-C7). Relative to the Pdi generated by BPES of 36.3 +/- 4.5 cm H2O (Mean +/- SEM), occluded Pdi(s) produced by UPMS, BPMS, PCMS, ACMS, and a combined PCMS + ACMS were 51.7%, 61.5%, 22.4%, 100.3%, and 104.5% of the maximal Pdi, respectively. Pdi(s) produced by UPMS, BPMS, PCMS, ACMS, and combined ACMS + PCMS were 38.0%, 45.2%, 16.5%, 73.8%, and 76.8%, respectively, of the Pdi induced by VRES (C5-C7) (48.0 +/- 3.9 cm H2O). The maximal Pdi(s) generated during ACMS and combined PCMS + ACMS were higher than the maximal Pdi(s) generated during UPMS, BPMS, or PCMS (p < 0.05). ACMS alone induced 129.8% of the inspiratory flow (73.0 +/- 9.4 L/ min) and 77.5% of the volume (626 +/- 556 ml) induced by BPES. ACMS and combined PCMS + ACMS produce a greater inspiratory pressure than UPMS, BPMS or PCMS. ACMS can be used to generate sufficient inspiratory pressure, flow, and volume for activation of the inspiratory muscles.

  6. Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals.

    PubMed

    Bailey, Ryan S; Casey, Kevin P; Pawar, Sachin S; Garcia, Guilherme J M

    2017-01-01

    Historically, otolaryngologists have focused on nasal resistance to airflow and minimum airspace cross-sectional area as objective measures of nasal obstruction using methods such as rhinomanometry and acoustic rhinometry. However, subjective sensation of nasal patency may be more associated with activation of cold receptors by inspired air than with respiratory effort. To investigate whether subjective nasal patency correlates with nasal mucosal temperature in healthy individuals. Healthy adult volunteers first completed the Nasal Obstruction Symptom Evaluation (NOSE) and a unilateral visual analog scale to quantify subjective nasal patency. A miniaturized thermocouple sensor was then used to record nasal mucosal temperature bilaterally in 2 locations along the nasal septum: at the vestibule and across from the inferior turbinate head. Nasal mucosal temperature and subjective patency scores in healthy individuals. The 22 healthy adult volunteers (12 [55%] male; mean [SD] age, 28.3 [7.0] years) had a mean (SD) NOSE score of 5.9 (8.4) (range, 0-30) and unilateral VAS score of 1.2 (1.4) (range, 0-5). The range of temperature oscillations during the breathing cycle, defined as the difference between end-expiratory and end-inspiratory temperatures, was greater during deep breaths (mean [SD] change in temperature, 6.2°C [2.6°C]) than during resting breathing (mean [SD] change in temperature, 4.2°C [2.3°C]) in both locations (P < .001). Mucosal temperature measured at the right vestibule had a statistically significant correlation with both right-side visual analog scale score (Pearson r = -0.55; 95% CI, -0.79 to -0.17; P = .008) and NOSE score (Pearson r = -0.47; 95% CI, -0.74 to -0.06; P = .03). No other statistically significant correlations were found between mucosal temperature and subjective nasal patency scores. Nasal mucosal temperature was lower (mean of 1.5°C lower) in the first cavity to be measured, which was the right cavity in all

  7. CPAP and High-Flow Nasal Cannula Oxygen in Bronchiolitis.

    PubMed

    Sinha, Ian P; McBride, Antonia K S; Smith, Rachel; Fernandes, Ricardo M

    2015-09-01

    Severe respiratory failure develops in some infants with bronchiolitis because of a complex pathophysiologic process involving increased airways resistance, alveolar atelectasis, muscle fatigue, and hypoxemia due to mismatch between ventilation and perfusion. Nasal CPAP and high-flow nasal cannula (HFNC) oxygen may improve the work of breathing and oxygenation. Although the mechanisms behind these noninvasive modalities of respiratory support are not well understood, they may help infants by way of distending pressure and delivery of high concentrations of warmed and humidified oxygen. Observational studies of varying quality have suggested that CPAP and HFNC may confer direct physiologic benefits to infants with bronchiolitis and that their use has reduced the need for intubation. No trials to our knowledge, however, have compared CPAP with HFNC in bronchiolitis. Two randomized trials compared CPAP with oxygen delivered by low-flow nasal cannula or face mask and found some improvements in blood gas results and some physiologic parameters, but these trials were unable to demonstrate a reduction in the need for intubation. Two trials evaluated HFNC in bronchiolitis (one comparing it with headbox oxygen, the other with nebulized hypertonic saline), with the results not seeming to suggest important clinical or physiologic benefits. In this article, we review the pathophysiology of respiratory failure in bronchiolitis, discuss these trials in detail, and consider how future research studies may be designed to best evaluate CPAP and HFNC in bronchiolitis.

  8. Effects of inspiratory and expiratory resistance in divers' breathing apparatus.

    PubMed

    Warkander, D E; Nagasawa, G K; Lundgren, C E

    2001-01-01

    This study was performed to determine if inspiratory breathing resistance causes greater or smaller changes than expiratory resistance. Unacceptable inspiratory resistances were also determined. Five subjects exercised at 60% of their VO2max while immersed in a hyperbaric chamber. The chamber was pressurized to either 147 kPa (1.45 atm abs, 4.5 msw, 15 fsw) or 690 kPa (6.8 atm abs, 57 msw, 190 fsw). Breathing resistance was imposed on the inspiratory or expiratory side and was as high as 0.8-1.2 kPa liter(-1) x s(-1) (8-12 cm H2O x liter(-1) x s(-1)) at a flow of 2-3 liter x s(-1) at 1 atm abs., the other side being unloaded. The subjects reacted to the imposed load by prolonging the phase of breathing that was loaded. Inspiratory breathing resistance caused greater changes than expiratory resistance in end-tidal CO2, dyspnea scores, maximum voluntary ventilation, and respiratory duty cycle. Using previously published criteria for acceptable levels of dyspnea scores and the CO2 levels, we found that an inspiratory resistance inducing a volume-averaged pressure of 1.5 kPa is not acceptable. Similarly, an expiratory resistance should not induce a volume-averaged pressure exceeding 2.0 kPa

  9. A Comparison of Over-the-Counter Mechanical Nasal Dilators: A Systematic Review.

    PubMed

    Kiyohara, Nicole; Badger, Christopher; Tjoa, Tjoson; Wong, Brian

    2016-09-01

    The internal nasal valve is the narrowest part of the nasal airway and a common site of inspiratory collapse and obstruction of nasal airflow. Over-the-counter mechanical nasal dilators are an alternative to surgical intervention that attempts to improve airflow through the internal nasal valve. To determine the efficacy of over-the-counter mechanical nasal dilators and classify these products by mechanism. A database of 33 available over-the-counter mechanical nasal dilators was generated via a PubMed search as well as an internet search via Amazon.com and Google, conducted from April 1, 2013, through December 31, 2015. Products determined to be unavailable or discontinued were excluded from the database. Of the devices examined in published literature, efficacy was based on objective measures, such as measured airflow, the cross-sectional area of the nasal valve, and changes in resistance. Measures of reported sleep quality or patient perception were excluded. An analysis of each product's mechanism revealed 4 broad classes: external nasal dilator strips, nasal stents, nasal clips, and septal stimulators. A review demonstrated 5 studies supporting the use of external nasal dilator strips, 4 studies supporting the use of nasal clips, 1 study supporting the use of nasal stents, and no studies supporting the use of septal stimulators. Our findings suggest that external nasal dilator strips and nasal clips effectively relieve obstruction of the internal nasal valve and may be an alternative to surgical intervention in some patients.

  10. ASTHMA, CHRONIC BRONCHITIS AND EMPHYSEMA—The Use of Intermittent Positive Pressure Breathing with Inspiratory Flow Rate Control: A Review of the Literature

    PubMed Central

    Sheldon, Gerard P.

    1963-01-01

    In chronic obstructive lung disease (asthma, chronic bronchitis, obstructive emphysema) there is a segmental reduction in the caliber of the airways, which always results in obstruction to air-flow. Increased airway resistance is a physiological expression of airway obstruction. The addition of inspiratory flow rate control to an intermittent positive pressure breathing device permits slow filling of a lung with obstructed airways, and is presented as a simple means of reducing the high pulmonary flow resistance and increasing the tidal volume. ImagesFigure 1. PMID:13977070

  11. Inspiratory High Frequency Airway Oscillation Attenuates Resistive Loaded Dyspnea and Modulates Respiratory Function in Young Healthy Individuals

    PubMed Central

    Morris, Theresa; Sumners, David Paul; Green, David Andrew

    2014-01-01

    Direct chest-wall percussion can reduce breathlessness in Chronic Obstructive Pulmonary Disease and respiratory function may be improved, in health and disease, by respiratory muscle training (RMT). We tested whether high-frequency airway oscillation (HFAO), a novel form of airflow oscillation generation can modulate induced dyspnoea and respiratory strength and/or patterns following 5 weeks of HFAO training (n = 20) compared to a SHAM-RMT (conventional flow-resistive RMT) device (n = 15) in healthy volunteers (13 males; aged 20–36 yrs). HFAO causes oscillations with peak-to-peak amplitude of 1 cm H2O, whereas the SHAM-RMT device was identical but created no pressure oscillation. Respiratory function, dyspnoea and ventilation during 3 minutes of spontaneous resting ventilation, 1 minute of maximal voluntary hyperventilation and 1 minute breathing against a moderate inspiratory resistance, were compared PRE and POST 5-weeks of training (2×30 breaths at 70% peak flow, 5 days a week). Training significantly reduced NRS dyspnoea scores during resistive loaded ventilation, both in the HFAO (p = 0.003) and SHAM-RMT (p = 0.005) groups. Maximum inspiratory static pressure (cm H2O) was significantly increased by HFAO training (vs. PRE; p<0.001). Maximum inspiratory dynamic pressure was increased by training in both the HFAO (vs. PRE; p<0.001) and SHAM-RMT (vs. PRE; p = 0.021) groups. Peak inspiratory flow rate (L.s−1) achieved during the maximum inspiratory dynamic pressure manoeuvre increased significantly POST (vs. PRE; p = 0.001) in the HFAO group only. HFAO reduced inspiratory resistive loading–induced dyspnoea and augments static and dynamic maximal respiratory manoeuvre performance in excess of flow-resistive IMT (SHAM-RMT) in healthy individuals without the respiratory discomfort associated with RMT. PMID:24651392

  12. High-flow nasal prong oxygen therapy or nasopharyngeal continuous positive airway pressure for children with moderate-to-severe respiratory distress?*.

    PubMed

    ten Brink, Fia; Duke, Trevor; Evans, Janine

    2013-09-01

    The aim of this study was to compare the use of high-flow nasal prong oxygen therapy to nasopharyngeal continuous positive airway pressure in a PICU at a tertiary hospital; to understand the safety and effectiveness of high-flow nasal prong therapy; in particular, what proportion of children require escalation of therapy, whether any bedside monitoring data predict stability or need for escalation, and complications of the therapies. This was a prospective observational study of the first 6 months after the introduction of high-flow nasal prong oxygen therapy at the Royal Children's Hospital in Melbourne. Data were collected on all children who were managed with either high-flow nasal prong oxygen therapy or nasopharyngeal continuous positive airway pressure. The mode of respiratory support was determined by the treating medical staff. Data were collected on each patient before the use of high-flow nasal prong or nasopharyngeal continuous positive airway pressure, at 2 hours after starting the therapy, and the children were monitored and data collected until discharge from the ICU. Therapy was considered to be escalated if children on high-flow nasal prong required a more invasive form or higher level of respiratory support, including nasopharyngeal continuous positive airway pressure or mask bilevel positive airway pressure or endotracheal intubation and mechanical ventilation. Therapy was considered to be escalated if children on nasopharyngeal continuous positive airway pressure required bilevel positive airway pressure or intubation and mechanical ventilation. As the first mode of respiratory support, 72 children received high-flow nasal prong therapy and 37 received nasopharyngeal continuous positive airway pressure. Forty-four patients (61%) who received high-flow nasal prong first were weaned to low-flow oxygen or to room air and 21 (29%) required escalation of respiratory support, compared with children on nasopharyngeal continuous positive airway pressure

  13. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    PubMed

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved

  14. The Effect of Inspiratory Muscle Training on Respiratory and Limb Locomotor Muscle Deoxygenation During Exercise with Resistive Inspiratory Loading.

    PubMed

    Turner, L A; Tecklenburg-Lund, S L; Chapman, R; Shei, R-J; Wilhite, D P; Mickleborough, T

    2016-07-01

    We investigated how inspiratory muscle training impacted respiratory and locomotor muscle deoxygenation during submaximal exercise with resistive inspiratory loading. 16 male cyclists completed 6 weeks of either true (n=8) or sham (n=8) inspiratory muscle training. Pre- and post-training, subjects completed 3, 6-min experimental trials performed at ~80%  ˙VO2peak with interventions of either moderate inspiratory loading, heavy inspiratory loading, or maximal exercise imposed in the final 3 min. Locomotor and respiratory muscle oxy-, deoxy-, and total-haemoglobin and myoglobin concentration was continuously monitored using near-infrared spectroscopy. Locomotor muscle deoxygenation changes from 80%  ˙VO2peak to heavy inspiratory loading were significantly reduced pre- to post-training from 4.3±5.6 µM to 2.7±4.7 µM. Respiratory muscle deoxygenation was also significantly reduced during the heavy inspiratory loading trial (4.6±3.5 µM to 1.9±1.5 µM) post-training. There was no significant difference in oxy-, deoxy-, or total-haemoglobin and myoglobin during any of the other loading trials, from pre- to post-training, in either group. After inspiratory muscle training, highly-trained cyclists exhibited decreased locomotor and respiratory muscle deoxygenation during exercise with heavy inspiratory loading. These data suggest that inspiratory muscle training reduces oxygen extraction by the active respiratory and limb muscles, which may reflect changes in respiratory and locomotor muscle oxygen delivery. © Georg Thieme Verlag KG Stuttgart · New York.

  15. High flow through a nasal cannula and CPAP effect in a simulated infant model.

    PubMed

    Volsko, Teresa A; Fedor, Kathy; Amadei, Jason; Chatburn, Robert L

    2011-12-01

    Limited data are available to describe the CPAP effects that can be expected when using high flow with a traditional nasal cannula. To describe the relationship between the pressure generated at the airway opening and flow through a nasal cannula using a simulated infant model. We hypothesized that positive pressure generated by a standard cannula at flows > 2 L/min would be minimal and clinically unimportant. Nares were simulated with holes drilled in a plastic fixture. A nares template for CPAP prongs served as a sizing template for the holes. Small, medium, and large nares fixtures were constructed and connected to a lung simulator that simulated spontaneous breathing. Respiratory muscle pressure was simulated by setting a waveform and adjusting the amplitude to deliver a range of tidal volumes (V(T)) from 3 mL to 12 mL. Lung compliance and resistance were set at 0.5 mL/cm H(2)O and 125 cm H(2)O/L/s, respectively. Nasal cannulas were inserted in the model nares. We assured that the prong occlusion of the nares did not exceed 50%. Cannula flow was adjusted from 2-6 L/min in 1-L/min increments. Data were averaged over 20 breaths. Mean airway pressure and percent change in V(T) were recorded. The greatest effect on V(T) (mean ± SD 0.16 ± 0.10 mL) and pressure change (mean ± SD 0.7 ± 0.5 cm H(2)O) occurred with the premature cannula. The least effect on pressure (mean ± SD 0.3 ± 0.22 cm H(2)O) and V(T) change (mean ± SD 0.01 ± 0.02 mL) occurred with the infant cannula. Clinically important pressures were not generated by high flows with a standard nasal cannula. The differences in spontaneous V(T) across all flows were negligible.

  16. An evaluation of 2 new devices for nasal high-flow gas therapy.

    PubMed

    Waugh, Jonathan B; Granger, Wesley M

    2004-08-01

    The traditional nasal cannula with bubble humidifier is limited to a maximum flow of 6 L/min to minimize the risk of complications. We conducted a bench study of 2 new Food and Drug Administration-approved nasal cannula/humidifier products designed to deliver at flows> 6 L/min. Using a digital psychrometer we measured the relative humidity and temperature of delivered gas from each device, at 5 L/min increments over the specified functional high-flow range. The Salter Labs unit achieved 72.5-78.7% relative humidity (5-15 L/min range) at ambient temperature (21-23 degrees C). The Vapotherm device achieved 99.9% relative humidity at a temperature setting of 37 degrees C (5-40 L/min). Both devices meet minimum humidification standards and offer practical new treatment options. The patient-selection criteria are primarily the severity of the patient's condition and cost.

  17. Association between desloratadine and prednisolone in the treatment of children with acute symptoms of allergic rhinitis: a double-blind, randomized and controlled clinical trial.

    PubMed

    Wandalsen, Gustavo F; Miranda, Carolina; Ensina, Luis Felipe; Sano, Flavio; Amazonas, Roberto Bleul; Silva, Joyce Macedo da; Solé, Dirceu

    A combination of antihistamines and oral corticosteroids is often used to treat acute symptoms of allergic rhinitis. To evaluate safety and efficacy of desloratadine plus prednisolone in the treatment of acute symptoms of children (2-12 years) with allergic rhinitis, and to compare it to dexchlorpheniramine plus betamethasone. Children with moderate/severe persistent allergic rhinitis and symptomatic (nasal symptoms score [0-12]≥6) were allocated in a double-blind, randomized fashion to receive dexchlorpheniramine plus betamethasone (n=105; three daily doses) or desloratadine plus prednisolone (n=105; single dose followed by two of placebo) for 7 days. At the beginning and end of the evaluation, the following were obtained: nasal symptoms score, extra nasal symptoms score, peak nasal inspiratory flow, blood biochemistry, and electrocardiogram. Ninety-six children of the dexchlorpheniramine plus betamethasone group and 98 of the desloratadine plus prednisolone group completed the protocol. The two groups were similar regarding initial and final nasal symptoms scores, extra nasal symptoms scores and peak nasal inspiratory flow. A drop of 76.4% and 79.1% for nasal symptoms score, 86.0% and 79.2% for extra nasal symptoms score, as well as an increase of 25.2% and 24.3% for peak nasal inspiratory flow occurred for those treated with desloratadine plus prednisolone and dexchlorpheniramine plus betamethasone, respectively. There were no significant changes in blood chemistry. Sinus tachycardia was the most frequent electrocardiogram change, but with no clinical significance. Drowsiness was reported significantly more often among those of dexchlorpheniramine plus betamethasone group (17.14%×8.57%, respectively). The desloratadine plus prednisolone combination was able to effectively control acute symptoms of rhinitis in children, improving symptoms and nasal function. Compared to the dexchlorpheniramine plus betamethasone combination, it showed similar clinical action

  18. High-Flow Nasal Oxygen vs Noninvasive Positive Airway Pressure in Hypoxemic Patients After Cardiothoracic Surgery: A Randomized Clinical Trial.

    PubMed

    Stéphan, François; Barrucand, Benoit; Petit, Pascal; Rézaiguia-Delclaux, Saida; Médard, Anne; Delannoy, Bertrand; Cosserant, Bernard; Flicoteaux, Guillaume; Imbert, Audrey; Pilorge, Catherine; Bérard, Laurence

    2015-06-16

    Noninvasive ventilation delivered as bilevel positive airway pressure (BiPAP) is often used to avoid reintubation and improve outcomes of patients with hypoxemia after cardiothoracic surgery. High-flow nasal oxygen therapy is increasingly used to improve oxygenation because of its ease of implementation, tolerance, and clinical effectiveness. To determine whether high-flow nasal oxygen therapy was not inferior to BiPAP for preventing or resolving acute respiratory failure after cardiothoracic surgery. Multicenter, randomized, noninferiority trial (BiPOP Study) conducted between June 15, 2011, and January 15, 2014, at 6 French intensive care units. A total of 830 patients who had undergone cardiothoracic surgery, of which coronary artery bypass, valvular repair, and pulmonary thromboendarterectomy were the most common, were included when they developed acute respiratory failure (failure of a spontaneous breathing trial or successful breathing trial but failed extubation) or were deemed at risk for respiratory failure after extubation due to preexisting risk factors. Patients were randomly assigned to receive high-flow nasal oxygen therapy delivered continuously through a nasal cannula (flow, 50 L/min; fraction of inspired oxygen [FiO2], 50%) (n = 414) or BiPAP delivered with a full-face mask for at least 4 hours per day (pressure support level, 8 cm H2O; positive end-expiratory pressure, 4 cm H2O; FiO2, 50%) (n = 416). The primary outcome was treatment failure, defined as reintubation, switch to the other study treatment, or premature treatment discontinuation (patient request or adverse effects, including gastric distention). Noninferiority of high-flow nasal oxygen therapy would be demonstrated if the lower boundary of the 95% CI were less than 9%. Secondary outcomes included mortality during intensive care unit stay, changes in respiratory variables, and respiratory complications. High-flow nasal oxygen therapy was not inferior to BiPAP: the treatment

  19. Evaluating the Effect of Flow and Interface Type on Pressures Delivered With Bubble CPAP in a Simulated Model.

    PubMed

    Bailes, Stephanie A; Firestone, Kimberly S; Dunn, Diane K; McNinch, Neil L; Brown, Miraides F; Volsko, Teresa A

    2016-03-01

    Bubble CPAP, used for spontaneously breathing infants to avoid intubation or postextubation support, can be delivered with different interface types. This study compared the effect that interfaces had on CPAP delivery. We hypothesized that there would be no difference between set and measured levels between interface types. A validated preterm infant nasal airway model was attached to the ASL 5000 breathing simulator. The simulator was programmed to deliver active breathing of a surfactant-deficient premature infant with breathing frequency at 70 breaths/min inspiratory time of 0.30 s, resistance of 150 cm H2O/L/s, compliance of 0.5 mL/cm H2O, tidal volume of 5 mL, and esophageal pressure of -10 cm H2O. Nasal CPAP prongs, size 4030, newborn and infant RAM cannulas were connected to a nasal airway model and a bubble CPAP system. CPAP levels were set at 4, 5, 6, 7, 8, and 9 cm H2O with flows of 6, 8, and 10 L/min each. Measurements were recorded after 1 min of stabilization. The analysis was performed using SAS 9.4. The Kolmogorov-Smirnov test assessed normality of the data. The Friedman test was used to compare non-normally distributed repeated measures. The Wilcoxon signed-rank test was used to conduct post hoc analysis. All tests were 2-sided, and P values of <.05 were considered as indicating significant differences unless otherwise indicated. At lower set CPAP levels, 4-6 cm H2O, measured CPAP dropped precipitously with the nasal prongs with the highest flow setting. At higher CPAP levels, 7-9 cm H2O measured CPAP concomitantly increased as the flow setting increased. Statistically significant differences in set and measured CPAP occurred for all devices across all CPAP levels, with the measured CPAP less than set for all conditions, P < .001. Set flow had a profound effect on measured CPAP. The concomitant drop in measured pressure with high and low flows could be attributed to increased resistance to spontaneous breathing or insufficient flow to meet

  20. Role of nasal challenge and local eosinophilia in indirect exposure to cat in allergic rhinitis patients.

    PubMed

    Al Ahmad, M; Arifhodzic, N; Nurkic, J; Jusufovic, E; Hanoun, A L; Rodriguez, T

    2018-01-17

    Introduction. Sensitization to cat allergens is common worldwide. Currently, there is a trend towards costly and often unavailable diagnostic analysis. Objectives. The aim is to assess the reliability of skin prick test (SPT) and serum specific IgE (ssIgE) to cat sensitization, by performing nasal challenge test (NCT) in a community with low cat ownership but common presence of stray cats. Patients and methods. Forty-one pa-tients with perennial allergic rhinitis (AR) who were mono or polysensitized (including cat) were included. We had 31 cat non-owners and 10 present cat owners. SPT (> 5 mm / diameter), ssIgE (≥ 0.70 IU/ml), nasal smear for eosinophil (Eo) and NCT were compared between groups. Outcomes included nasal challenge score, nasal Eo positivity, peak inspiratory and expiratory flow (PIF and PEF) 2 and 8 hours after the NCT, and were compared to baseline. Results. Baseline SPT wheal size and ssIgE level were similar in both groups. NCT positivity was more frequent in cat owners. The strongest nasal reaction was on the top concentration in both groups. Nasal Eo positivity in cat owners was higher before and 2 hours after NCT, but similar to non-owners at last measurement. NCT positive cat non-owners had bigger SPT wheal size than NCT negative non-owners, but smaller than NCT positive cat owners. In contrast to PEF, a significant fall in PIF was noticed in both groups. Mono and polysensitised patients showed similar NCT positivity. Conclusion. Stray cats may pose a relevant risk of developing perennial AR. Regardless of cat ownership status, SPT and ssIgE should be the first diagnostic tool. Nasal Eo and NCT seem to be good diagnostic tools in cat non-owners if diagnosis is elusive.

  1. Regional peak mucosal cooling predicts the perception of nasal patency.

    PubMed

    Zhao, Kai; Jiang, Jianbo; Blacker, Kara; Lyman, Brian; Dalton, Pamela; Cowart, Beverly J; Pribitkin, Edmund A

    2014-03-01

    Nasal obstruction is the principal symptom that drives patients with rhinosinus disease to seek medical treatment. However, patient perception of obstruction often bears little relationship to actual measured physical obstruction of airflow. This lack of an objective clinical tool hinders effective diagnosis and treatment. Previous work has suggested that the perception of nasal patency may involve nasal trigeminal activation by cool inspiratory airflow; we attempt to derive clinically relevant variables following this phenomenon. Prospective healthy cohort. Twenty-two healthy subjects rated unilateral nasal patency in controlled room air using a visual analog scale, followed by rhinomanometry, acoustic rhinometry, and butanol lateralization thresholds (BLTs). Each subject then immediately underwent a computed tomography scan, enabling the construction of a real-time computational fluid dynamics (CFD) nasal airway model, which was used to simulate nasal mucosa heat loss during steady resting breathing. Among all measured and computed variables, only CFD-simulated peak heat loss posterior to the nasal vestibule significantly correlated with patency ratings (r = -0.46, P < .01). Linear discriminant analysis predicted patency categories with 89% success rate, with BLT and rhinomanometric nasal resistance being two additional significant variables. As validation, CFD simulated nasal resistance significantly correlated with rhinomanometrically measured resistance (r = 0.41, P < .01). These results reveal that our noses are sensing patency via a mechanism involving localized peak nasal mucosal cooling. The analysis provides a strong rationale for combining the individualized CFD with other objective and neurologic measures to create a novel clinical tool to diagnose nasal obstruction and to predict and evaluate treatment outcomes. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Impact of High-flow Nasal Cannula Therapy in Quality Improvement and Clinical Outcomes in a Non-invasive Ventilation Device-free Pediatric Intensive Care Unit.

    PubMed

    Can, Fulva Kamit; Anil, Ayse Berna; Anil, Murat; Zengin, Neslihan; Bal, Alkan; Bicilioglu, Yuksel; Gokalp, Gamze; Durak, Fatih; Ince, Gulberat

    2017-10-15

    To analyze the change in quality indicators due to the use of high-flow nasal cannula therapy as a non-invasive ventilation method in children with respiratory distress/failure in a non-invasive ventilation device-free pediatric intensive care unit. Retrospective chart review of children with respiratory distress/failure admitted 1 year before (period before high-flow nasal cannula therapy) and 1 year after (period after high-flow nasal cannula therapy) the introduction of high-flow nasal cannula therapy. We compared quality indicators as rate of mechanical ventilation, total duration of mechanical ventilation, rate of re-intubation, pediatric intensive care unit length of stay, and mortality rate between these periods. Between November 2012 and November 2014, 272 patients: 141 before and 131 after high-flow nasal cannula therapy were reviewed (median age was 20.5 mo). Of the patients in the severe respiratory distress/failure subgroup, the rate of intubation was significantly lower in period after than in period before high-flow nasal cannula therapy group (58.1% vs. 76.1%; P <0.05). The median pediatric intensive care unit length of stay was significantly shorter in patients who did not require mechanical ventilation in the period after than in the period before high-flow nasal cannula therapy group (3d vs. 4d; P<0,05). Implementation of high-flow nasal cannula therapy in pediatric intensive care unit significantly improves the quality of therapy and its outcomes.

  3. Evaluation and comparison of nasal airway flow patterns among three subjects from Caucasian, Chinese and Indian ethnic groups using computational fluid dynamics simulation.

    PubMed

    Zhu, Jian Hua; Lee, Heow Pueh; Lim, Kian Meng; Lee, Shu Jin; Wang, De Yun

    2011-01-31

    Nasal airflow is one of the most important determinants for nasal physiology. During the long evolution of human beings, different races have developed their own attributes of nasal morphologies which result in variations of nasal airflow patterns and nasal functions. This study evaluated and compared the effects of differences of nasal morphology among three healthy male subjects from Caucasian, Chinese and Indian ethnic groups on nasal airflow patterns using computational fluid dynamics simulation. By examining the anterior nasal airway, the nasal indices and the nostril shapes of the three subjects were found to be similar to nasal cavities of respective ethnic groups. Computed tomography images of these three subjects were obtained to reconstruct 3-dimensional models of nasal cavities. To retain the flow characteristics around the nasal vestibules, a 40 mm-radius semi sphere was assembled around the human face for the prescription of zero ambient gauge pressure. The results show that more airflow tends to pass through the middle passage of the nasal airway in the Caucasian model, and through the inferior portion in the Indian model. The Indian model was found with extremely low flow flux flowing through the olfactory region. The sizes of vortexes near the anterior cavity were found to be correlated with the angles between the upper nasal valve wall and the anterior head of the nasal cavity. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Position paper on nasal obstruction: evaluation and treatment.

    PubMed

    Valero, A; Navarro, A M; Del Cuvillo, A; Alobid, I; Benito, J R; Colás, C; de Los Santos, G; Fernández Liesa, R; García-Lliberós, A; González-Pérez, R; Izquierdo-Domínguez, A; Jurado-Ramos, A; Lluch-Bernal, M M; Montserrat Gili, J R; Mullol, J; Puiggròs Casas, A; Sánchez-Hernández, M C; Vega, F; Villacampa, J M; Armengot-Carceller, M; Dordal, M T

    2018-01-01

    Nasal obstruction (NO) is defined as the subjective perception of discomfort or difficulty in the passage of air through the nostrils. It is a common reason for consultation in primary and specialized care and may affect up to 30%-40% of the population. It affects quality of life (especially sleep) and lowers work efficiency. The aim of this document is to agree on how to treat NO, establish a methodology for evaluating and diagnosing it, and define an individualized approach to its treatment. NO can be unilateral or bilateral, intermittent or persistent and may be caused by local or systemic factors, which may be anatomical, inflammatory, neurological, hormonal, functional, environmental, or pharmacological in origin. Directed study of the medical history and physical examination are key for diagnosing the specific cause. NO may be evaluated using subjective assessment tools (visual analog scale, symptom score, standardized questionnaires) or by objective estimation (active anterior rhinomanometry, acoustic rhinometry, peak nasal inspiratory flow). Although there is little correlation between the results, they may be considered complementary and not exclusive. Assessing the impact on quality of life through questionnaires standardized according to the underlying disease is also advisable. NO is treated according to its cause. Treatment is fundamentally pharmacological (topical and/or systemic) when the etiology is inflammatory or functional. Surgery may be necessary when medical treatment fails to complement or improve medical treatment or when other therapeutic approaches are not possible. Combinations of surgical techniques and medical treatment may be necessary.

  5. Breathing response of the tegu lizard to 1-4% CO2 in the mouth and nose or inspired into the lungs.

    PubMed

    Ballam, G O

    1985-12-01

    This study investigated the influence on ventilation of elevated CO2 in the nasal and buccal cavities (NaBuCO2) vs the effect of elevated CO2 levels inspired into the lungs (LuCO2). Separate gas sources were used to independently alter NaBuCO2 and LuCO2. As little as 1% NaBuCO2 or LuCO2 significantly increased the pause duration between the active expiratory-inspiratory cycles. Elevated NaBuCO2 caused minor changes in tidal volume, mean inspiratory and expiratory flow, and inspiratory and expiratory durations with a significant reduction in total ventilation. Elevated LuCO2 had little effect on inspiratory or expiratory durations but unlike CO2 in the upper airways, significantly increased tidal volume and mean inspiratory and expiratory flows. This study demonstrates that the increased pause duration seen in the tegu lizard to elevated environmental CO2 is due to a receptor response in the buccal or nasal cavities and also to elevated CO2 concentrations inspired into the lungs. Sensitivity of the ventilatory responses to CO2 in the upper airways is well within a physiologically relevant range.

  6. Immediate effect of benzalkonium chloride in decongestant nasal spray on the human nasal mucosal temperature.

    PubMed

    Lindemann, J; Leiacker, R; Wiesmiller, K; Rettinger, G; Keck, T

    2004-08-01

    Benzalkonium chloride is a preservative commonly used in nasal decongestant sprays. It has been suggested that benzalkonium chloride may be harmful to the nasal mucosa. Decongestion with the vasoconstrictor xylometazoline containing benzalkonium chloride has been shown to cause a significant reduction of the nasal mucosal temperature. The purpose of the present study was to determine the short-term influence of xylometazoline nasal spray with and without benzalkonium chloride on the nasal mucosal temperature. Healthy volunteers (30) were included in the study. Fifteen volunteers received xylometazoline nasal spray (1.0 mg/mL) containing benzalkonium chloride (0.1 mg/mL) and 15 age-matched subjects, received xylometazoline nasal spray without benzalkonium chloride. Using a miniaturized thermocouple the septal mucosal temperature was continuously measured at defined intranasal detection sites before and after application of the nasal spray. The mucosal temperature values did not significantly differ between the group receiving xylometazoline containing benzalkonium chloride and the group receiving xylometazoline spray without benzalkonium chloride before and after decongestion (P > 0.05). In both study groups septal mucosal temperatures significantly decreased after decongestion (P < 0.05) because of a reduction of the nasal mucosal blood flow following vasoconstriction. This study indicates that benzalkonium chloride itself does not seem to influence nasal blood flow and nasal mucosal temperature in topical nasal decongestants.

  7. A decrease in nasal CO2 stimulates breathing in the tegu lizard.

    PubMed

    Coates, E L; Furilla, R A; Ballam, G O; Bartlett, D

    1991-10-01

    Tegu lizards decrease ventilatory frequency (f) when constant CO2, as low as 0.4%, is delivered to the nasal cavities. In contrast, CO2, as high as 6%, pulsed into the nasal cavities during the expiratory phase of the breathing cycle does not alter f. The purpose of the present study was to investigate further the effect of nasal CO2 pattern on f in tegu lizards. Specifically, we tested: (1) whether f was affected by CO2 delivered to the nasal cavities during the inspiratory phase of the breathing cycle, and (2) whether pulsed decreases in nasal CO2 from 4% to 2% and from 4% to 0% would remove the f inhibition caused by constant nasal CO2. Ventilation was measured using a pneumotachograph and pressure transducer in-line with an endotracheal T-tube inserted through the glottis. CO2 was delivered to the nasal cavities through small tubes inserted into the external nares. Ventilatory frequency was not significantly altered when 4% CO2 was pulsed into the nasal cavities during inspiration. Dropping the CO2 in the nasal cavities from 4% to 0% at either 15 cycles/min (0.25 Hz) or for one cycle stimulated breathing. There was no significant difference between the f response to a drop in CO2 from 4% to 0% and that to a drop in CO2 from 4% to 2%. The failure to link the phasic CO2 ventilatory response to a phase in the respiratory cycle indicates that the nasal CO2 receptors do not participate in the breath-by-breath regulation of breathing in these lizards. The observation that small decreases in nasal CO2 abolished the f inhibition caused by constant nasal CO2 provides further evidence for the ability of the nasal CO2 receptors to distinguish between pulsed and constant CO2.

  8. Infant Flow Driver or single prong nasal continuous positive airway pressure: short-term physiological effects.

    PubMed

    Ahluwalia, J S; White, D K; Morley, C J

    1998-03-01

    The effectiveness of single prong nasal continuous positive airway pressure (CPAP) was compared with the Infant Flow Driver (IFD) in a crossover study in 20 neonates treated with > or = 30% oxygen by nasal CPAP. They were randomized to the device used at the start of the study. Each infant was studied for four consecutive 2-h periods alternating between single prong nasal CPAP and the IFD. The FiO2 from the IFD read 0.02 higher than the same setting on the ventilators used for single prong nasal CPAP. The IFD improved the mean (95% CI) of the FiO2 by 0.05 (0.02-0.08), p = 0.008. Taking into account the systematic error in the FiO2 between the devices the real mean improvement in FiO2 produced by the IFD was 0.03 (-0.005 to 0.06), p=0.09. There were no significant differences in respiratory rate, heart rate, blood pressure or comfort score of infants during periods of single nasal prong CPAP compared with periods on the IFD.

  9. Maximum static inspiratory and expiratory pressures with different lung volumes

    PubMed Central

    Lausted, Christopher G; Johnson, Arthur T; Scott, William H; Johnson, Monique M; Coyne, Karen M; Coursey, Derya C

    2006-01-01

    Background Maximum pressures developed by the respiratory muscles can indicate the health of the respiratory system, help to determine maximum respiratory flow rates, and contribute to respiratory power development. Past measurements of maximum pressures have been found to be inadequate for inclusion in some exercise models involving respiration. Methods Maximum inspiratory and expiratory airway pressures were measured over a range of lung volumes in 29 female and 19 male adults. A commercial bell spirometry system was programmed to occlude airflow at nine target lung volumes ranging from 10% to 90% of vital capacity. Results In women, maximum expiratory pressure increased with volume from 39 to 61 cmH2O and maximum inspiratory pressure decreased with volume from 66 to 28 cmH2O. In men, maximum expiratory pressure increased with volume from 63 to 97 cmH2O and maximum inspiratory pressure decreased with volume from 97 to 39 cmH2O. Equations describing pressures for both sexes are: Pe/Pmax = 0.1426 Ln( %VC) + 0.3402 R2 = 0.95 Pi/Pmax = 0.234 Ln(100 - %VC) - 0.0828 R2 = 0.96 Conclusion These results were found to be consistent with values and trends obtained by other authors. Regression equations may be suitable for respiratory mechanics models. PMID:16677384

  10. Specific inspiratory muscle warm-up enhances badminton footwork performance.

    PubMed

    Lin, Hua; Tong, Tom Kwokkeung; Huang, Chuanye; Nie, Jinlei; Lu, Kui; Quach, Binh

    2007-12-01

    The effects of inspiratory muscle (IM) warm-up on IM function and on the maximum distance covered in a subsequent incremental badminton-footwork test (FWmax) were examined. Ten male badminton players were recruited to perform identical tests in three different trials in a random order. The control trial did not involve an IM warm-up, whereas the placebo and experimental trials did involve an IM warm-up consisting of two sets of 30-breath manoeuvres with an inspiratory pressure-threshold load equivalent to 15% (PLA) and 40% (IMW) maximum inspiratory mouth pressure, respectively. In the IMW trial, IM function was improved with 7.8%+/-4.0% and 6.9%+/-3.5% increases from control found in maximal inspiratory pressure at zero flow (P0) and maximal rate of P0 development (MRPD), respectively (p<0.05). FWmax was enhanced 6.8%+/-3.7%, whereas the slope of the linear relationship of the increase in the rating of perceived breathlessness for every minute (RPB/min) was reduced (p<0.05). Reduction in blood lactate ([La-]b) accumulation was observed when the test duration was identical to that of the control trial (P<0.05). In the PLA trial, no parameter was changed from control. For the changes (Delta) in parameters in IMW (n=10), negative correlations were found between DeltaP0 and DeltaRPB/min (r2=0.58), DeltaMRPD and DeltaRPB/min (r2=0.48), DeltaRPB/min, and DeltaFWmax (r2=0.55), but not between Delta[La-]b accumulation and DeltaFWmax. Such findings suggest that the IM-specific warm-up improved footwork performance in the subsequent maximum incremental badminton-footwork test. The improved footwork was partly attributable to the reduced breathless sensation resulting from the enhanced IM function, whereas the contribution of the concomitant reduction in [La-]b accumulation was relatively minor.

  11. High-Flow Nasal Oxygen in Patient With Obstructive Sleep Apnea Undergoing Awake Craniotomy: A Case Report.

    PubMed

    Wong, Jaclyn W M; Kong, Amy H S; Lam, Sau Yee; Woo, Peter Y M

    2017-12-15

    Patients with obstructive sleep apnea are frequently considered unsuitable candidates for awake craniotomy due to anticipated problems with oxygenation, ventilation, and a potentially difficult airway. At present, only a handful of such accounts exist in the literature. Our report describes the novel use of high-flow nasal oxygen therapy for a patient with moderate obstructive sleep apnea who underwent an awake craniotomy under deep sedation. The intraoperative application of high-flow nasal oxygen therapy achieved satisfactory oxygenation, maintained the partial carbon dioxide pressure within a reasonable range even during periods of deep sedation, permitted responsive patient monitoring during mapping, and provided excellent patient and surgeon satisfaction.

  12. [Effect of nasal CPAP on human diaphragm position and lung volume].

    PubMed

    Yoshimura, N; Abe, T; Kusuhara, N; Tomita, T

    1994-11-01

    The cephalic margin of the zone of apposition (ZOA) was observed with ultrasonography at ambient pressure and during nasal continuous positive airway pressure (nasal CPAP) in nine awake healthy males in a supine position. In a relaxed state at ambient pressure, there was a significant (p < 0.001) linear relationship between lung volume and the movement of the cephalic margin of the ZOA over the range from maximum expiratory position (MEP) to maximum inspiratory position (MIP). With nasal CPAP, functional residual capacity increased significantly (p < 0.01) in proportion to the increase in CPAP. At 20 cmH2O CPAP, the mean increase in volume at end expiration was 36% of the vital capacity measured at ambient pressure. The cephalic margin of the ZOA moved significantly (p < 0.01) in a caudal direction as CPAP was increased. At 20 cmH2O CPAP, the cephalic margin of the ZOA at end expiratory position (EEP) had moved 55% of the difference from MIP to MEP measured at ambient pressure. The end expiratory diaphragm position during nasal CPAP was lower than the diaphragm position at ambient pressure when lung volumes were equal. These results suggest that during nasal CPAP the chest wall is distorted from its relaxed configuration, with a decrease in rib cage expansion and an increase in outward displacement of the abdominal wall.

  13. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    PubMed

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  14. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    PubMed Central

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; p<0.001). With oronasal masks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  15. Effect of two doses of carbamylated allergoid extract of dust mite on nasal reactivity.

    PubMed

    Scalone, G; Compalati, E; Bruno, M E; Mistrello, G

    2013-11-01

    Background and Objective. Single SLIT studies with native allergen extracts support a dose-response effect for clinical and immunological outcomes. Conversely for carbamylated allergoids this dose-response effects is less evident, likely because the threshold for efficacy is more easily reached through the enhanced bioavailability of the extract consequent to the selective chemical modification. Thus this pilot study investigates the dose-response effect on nasal specific reactivity and safety of two unusual doses of carbamylated allergoid in patients mono-sensitized to house dust mites. Methods. A prospective open randomized study involved 6-65 year-old Italian patients with clinically relevant sensitization to house dust mites and positive response to nasal provocation challenge. Monomeric carbamylated allergoid was delivered once daily at the dose of 1000 AU or 2000 AU from June to September 2009, during the lowest level of mites exposure. Primary outcomes were the change of the threshold of allergen concentration for a positive nasal provocation test (NPT) before and after the treatment and the product safety. Secondary outcome was the change  in the mean percentage fall of peak nasal inspiratory flow (PNIF) following nasal challenge. Results. Thirty-four patients were enrolled. Fifteen in group 1 and 14 in group 2 concluded the study. After 12 weeks all patients treated in group 1 and all but one in group 2 showed an increase in the threshold dose provoking a positive NPT. Those with no symptoms onset with the highest dose delivered were 80% in group 1 and 78.6% in group 2 (p=0.92). From first to second challenge, the mean percentage fall of PNIF  was reduced with no statistical difference between groups (p=0.95), and with no difference between the final mean percentage falls (p=0.65). No serious adverse reactions occurred and the frequency of events, all mild, was similar in the two groups. Conclusions. Twelve weeks of carbamylated sublingual allergoid

  16. [Clinical analysis of nasal resistance and pulmonary function testing in patients with chronic nasal-sinusitis and nasal polyps].

    PubMed

    Liao, Hua; Shen, Ying; Wang, Pengjun

    2015-05-01

    To study the pulmonary function and nasal resistance characteristics of patients with chronic nose-sinusitis and nasal polyps (CRSwNP), to explore the evaluation role of nasal resistance in nasal ventilation function and the effect of endoscopic sinus surgery on pulmonary function in patients with CRSwNP. Fifty CRSwNP patients that met the study criteria were selected . The patients were performed endoscopic surgeries according to Messerklinger surgical procedures under general anesthesia. Extent of surgery was based on preoperative CT showing the range of the lesion of disease and endoscopic findings. Perioperative treatments contained intranasal corticosteroids, cephalosporin or penicillin antibiotics, nasal irrigation and other treatments. Main outcome measures included visual analog scale (VAS), endoscopic Lind-Kennedy scores, nasal resistence, pulmonary function in patientsone week before and after surgery, three months and six months after surgery. Pulmonary function includes forced expiratory volume in one second (FEV1), forced vital capacity FEV1/FVC and peak expiratory flow (PEF). The study found that there were significantly positive correlations among VAS score, Lund-Kennedy score and nasal resistance (P < 0.05) in CRSwNP patients, but there is a significantly negative correlation between VAS score, Lund-Kennedy score, nasal resistance and pulmonary function indexes of FEV1, FVC and PEF (P < 0.05). The VAS score, Lund-Kennedy score and nasal resistance values of CRSwNP patients were decreased significantly after comprehensive treatments with nasal endoscopic operation as the major one, the difference was statistically different (P < 0.05). And the pulmonary function indexs (FEV1, FVC, PEF) were significantly increased after surgery in CRSwNP patients. The nasal resistance can objectively and reliably reflect the degree of nasal congestion and the recovery of nasal function in CRSwNP patients after endoscopic sinus surgery. The detection method of nasal

  17. Breathing efficiency during inspiratory threshold loading in patients with chronic obstructive pulmonary disease.

    PubMed

    Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F

    1998-05-01

    Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.

  18. Numerical simulation of two consecutive nasal respiratory cycles: toward a better understanding of nasal physiology.

    PubMed

    de Gabory, Ludovic; Reville, Nicolas; Baux, Yannick; Boisson, Nicolas; Bordenave, Laurence

    2018-01-16

    Computational fluid dynamic (CFD) simulations have greatly improved the understanding of nasal physiology. We postulate that simulating the entire and repeated respiratory nasal cycles, within the whole sinonasal cavities, is mandatory to gather more accurate observations and better understand airflow patterns. A 3-dimensional (3D) sinonasal model was constructed from a healthy adult computed tomography (CT) scan which discretized in 6.6 million cells (mean volume, 0.008 mm 3 ). CFD simulations were performed with ANSYS©FluentTMv16.0.0 software with transient and turbulent airflow (k-ω model). Two respiratory cycles (8 seconds) were simulated to assess pressure, velocity, wall shear stress, and particle residence time. The pressure gradients within the sinus cavities varied according to their place of connection to the main passage. Alternations in pressure gradients induced a slight pumping phenomenon close to the ostia but no movement of air was observed within the sinus cavities. Strong movements were observed within the inferior meatus during expiration contrary to the inspiration, as in the olfactory cleft at the same time. Particle residence time was longer during expiration than inspiration due to nasal valve resistance, as if the expiratory phase was preparing the next inspiratory phase. Throughout expiration, some particles remained in contact with the lower turbinates. The posterior part of the olfactory cleft was gradually filled with particles that did not leave the nose at the next respiratory cycle. This pattern increased as the respiratory cycle was repeated. CFD is more efficient and reliable when the entire respiratory cycle is simulated and repeated to avoid losing information. © 2018 ARS-AAOA, LLC.

  19. High-Flow Nasal Cannula Oxygenation in Immunocompromised Patients With Acute Hypoxemic Respiratory Failure: A Groupe de Recherche Respiratoire en Réanimation Onco-Hématologique Study.

    PubMed

    Lemiale, Virginie; Resche-Rigon, Matthieu; Mokart, Djamel; Pène, Frédéric; Argaud, Laurent; Mayaux, Julien; Guitton, Christophe; Rabbat, Antoine; Girault, Christophe; Kouatchet, Achille; Vincent, François; Bruneel, Fabrice; Nyunga, Martine; Seguin, Amélie; Klouche, Kada; Colin, Gwenahel; Kontar, Loay; Perez, Pierre; Meert, Anne-Pascale; Benoit, Dominique D; Papazian, Laurent; Demoule, Alexandre; Chevret, Sylvie; Azoulay, Elie

    2017-03-01

    In immunocompromised patients with acute respiratory failure, invasive mechanical ventilation remains associated with high mortality. Choosing the adequate oxygenation strategy is of the utmost importance in that setting. High-flow nasal oxygen has recently shown survival benefits in unselected patients with acute respiratory failure. The objective was to assess outcomes of immunocompromised patients with hypoxemic acute respiratory failure treated with high-flow nasal oxygen. We performed a post hoc analysis of a randomized controlled trial of noninvasive ventilation in critically ill immunocompromised patients with hypoxemic acute respiratory failure. Twenty-nine ICUs in France and Belgium. Critically ill immunocompromised patients with hypoxemic acute respiratory failure. A propensity score-based approach was used to assess the impact of high-flow nasal oxygen compared with standard oxygen on day 28 mortality. Among 374 patients included in the study, 353 met inclusion criteria. Underlying disease included mostly malignancies (n = 296; 84%). Acute respiratory failure etiologies were mostly pneumonia (n = 157; 44.4%) or opportunistic infection (n = 76; 21.5%). Noninvasive ventilation was administered to 180 patients (51%). Invasive mechanical ventilation was ultimately needed in 142 patients (40.2%). Day 28 mortality was 22.6% (80 deaths). Throughout the ICU stay, 127 patients (36%) received high-flow nasal oxygen whereas 226 patients received standard oxygen. Ninety patients in each group (high-flow nasal oxygen or standard oxygen) were matched according to the propensity score, including 91 of 180 (51%) who received noninvasive ventilation. High-flow nasal oxygen was neither associated with a lower intubation rate (hazard ratio, 0.42; 95% CI, 0.11-1.61; p = 0.2) nor day 28 mortality (hazard ratio, 0.80; 95% CI, 0.45-1.42; p = 0.45). In immunocompromised patients with hypoxemic acute respiratory failure, high-flow nasal oxygen when compared with standard oxygen

  20. Inspiratory Muscle Training and Functional Capacity in Patients Undergoing Cardiac Surgery.

    PubMed

    Cordeiro, André Luiz Lisboa; de Melo, Thiago Araújo; Neves, Daniela; Luna, Julianne; Esquivel, Mateus Souza; Guimarães, André Raimundo França; Borges, Daniel Lago; Petto, Jefferson

    2016-04-01

    Cardiac surgery is a highly complex procedure which generates worsening of lung function and decreased inspiratory muscle strength. The inspiratory muscle training becomes effective for muscle strengthening and can improve functional capacity. To investigate the effect of inspiratory muscle training on functional capacity submaximal and inspiratory muscle strength in patients undergoing cardiac surgery. This is a clinical randomized controlled trial with patients undergoing cardiac surgery at Instituto Nobre de Cardiologia. Patients were divided into two groups: control group and training. Preoperatively, were assessed the maximum inspiratory pressure and the distance covered in a 6-minute walk test. From the third postoperative day, the control group was managed according to the routine of the unit while the training group underwent daily protocol of respiratory muscle training until the day of discharge. 50 patients, 27 (54%) males were included, with a mean age of 56.7±13.9 years. After the analysis, the training group had significant increase in maximum inspiratory pressure (69.5±14.9 vs. 83.1±19.1 cmH2O, P=0.0073) and 6-minute walk test (422.4±102.8 vs. 502.4±112.8 m, P=0.0031). We conclude that inspiratory muscle training was effective in improving functional capacity submaximal and inspiratory muscle strength in this sample of patients undergoing cardiac surgery.

  1. Effects of inspiratory muscle training on pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation: a randomized controlled trial.

    PubMed

    Zeren, Melih; Demir, Rengin; Yigit, Zerrin; Gurses, Hulya N

    2016-12-01

    To investigate the effects of inspiratory muscle training on pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation. Prospective randomized controlled single-blind study. Cardiology department of a university hospital. A total of 38 patients with permanent atrial fibrillation were randomly allocated to either a treatment group (n = 19; age 66.2 years (8.8)) or a control group (n = 19; age 67.1 years (6.4)). The training group received inspiratory muscle training at 30% of maximal inspiratory pressure for 15 minutes twice a day, 7 days a week, for 12 weeks alongside the standard medical treatment. The control group received standard medical treatment only. Spirometry, maximal inspiratory and expiratory pressures and 6-minute walking distance was measured at the beginning and end of the study. There was a significant increase in maximal inspiratory pressure (27.94 cmH 2 O (8.90)), maximal expiratory pressure (24.53 cmH 2 O (10.34)), forced vital capacity (10.29% (8.18) predicted), forced expiratory volume in one second (13.88% (13.42) predicted), forced expiratory flow 25%-75% (14.82% (12.44) predicted), peak expiratory flow (19.82% (15.62) predicted) and 6-minute walking distance (55.53 m (14.13)) in the training group (p < 0.01). No significant changes occurred in the control group (p > 0.05). Inspiratory muscle training can improve pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation. © The Author(s) 2016.

  2. Aerosol Delivery with Two Nebulizers Through High-Flow Nasal Cannula: A Randomized Cross-Over Single-Photon Emission Computed Tomography-Computed Tomography Study.

    PubMed

    Dugernier, Jonathan; Hesse, Michel; Jumetz, Thibaud; Bialais, Emilie; Roeseler, Jean; Depoortere, Virginie; Michotte, Jean-Bernard; Wittebole, Xavier; Ehrmann, Stephan; Laterre, Pierre-François; Jamar, François; Reychler, Gregory

    2017-10-01

    High-flow nasal cannula use is developing in ICUs. The aim of this study was to compare aerosol efficiency by using two nebulizers through a high-flow nasal cannula: the most commonly used jet nebulizer (JN) and a more efficient vibrating-mesh nebulizer (VN). Aerosol delivery of diethylenetriaminepentaacetic acid labeled with technetium-99m (4 mCi/4 mL) to the lungs by using a VN (Aerogen Solo ® ; Aerogen Ltd., Galway, Ireland) and a constant-output JN (Opti-Mist Plus Nebulizer ® ; ConvaTec, Bridgewater, NJ) through a high-flow nasal cannula (Optiflow ® ; Fisher & Paykel, New Zealand) was compared in six healthy subjects. Flow rate was set at 30 L/min through the heated humidified circuit. Pulmonary and extrapulmonary deposition was measured by single-photon emission computed tomography combined with a low-dose computed tomographic scan and by planar scintigraphy. Lung deposition was only 3.6 (2.1-4.4) and 1 (0.7-2)% of the nominal dose with the VN and the JN, respectively (p < 0.05). The JN showed higher retained doses than the VN. However, both nebulizers were associated with substantial deposition in the single limb circuit, the humidification chamber, and the nasal cannula [58.2 (51.6-61.6)% of the nominal dose with the VN versus 19.2 (15.8-22.9)% of the nominal dose with the JN, p < 0.05] and in the upper respiratory tract [17.6 (13.4-27.9)% of the nominal dose with the VN and 8.6 (6.0-11.0)% of the nominal dose with the JN, p < 0.05], especially in the nasal cavity. In the specific conditions of the study, pulmonary drug delivery through the high-flow nasal cannula is about 1%-4% of the initial amount of drugs placed in the nebulizer, despite the higher efficiency of the VN as compared with the JN.

  3. Diagnostic methods to assess inspiratory and expiratory muscle strength*

    PubMed Central

    Caruso, Pedro; de Albuquerque, André Luis Pereira; Santana, Pauliane Vieira; Cardenas, Leticia Zumpano; Ferreira, Jeferson George; Prina, Elena; Trevizan, Patrícia Fernandes; Pereira, Mayra Caleffi; Iamonti, Vinicius; Pletsch, Renata; Macchione, Marcelo Ceneviva; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Impairment of (inspiratory and expiratory) respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation); and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength. PMID:25972965

  4. The effectiveness of combining inspiratory muscle training with manual therapy and a therapeutic exercise program on maximum inspiratory pressure in adults with asthma: a randomized clinical trial.

    PubMed

    López-de-Uralde-Villanueva, Ibai; Candelas-Fernández, Pablo; de-Diego-Cano, Beatriz; Mínguez-Calzada, Orcález; Del Corral, Tamara

    2018-06-01

    The objective of this study was to evaluate whether the addition of manual therapy and therapeutic exercise protocol to inspiratory muscle training was more effective in improving maximum inspiratory pressure than inspiratory muscle training in isolation. This is a single-blinded, randomized controlled trial. In total, 43 patients with asthma were included in this study. The patients were allocated into one of the two groups: (1) inspiratory muscle training ( n = 21; 20-minute session) or (2) inspiratory muscle training (20-minute session) combined with a program of manual therapy (15-minute session) and therapeutic exercise (15-minute session; n = 22). All participants received 12 sessions, two days/week, for six weeks and performed the domiciliary exercises protocol. The main measures such as maximum inspiratory pressure, spirometric measures, forward head posture, and thoracic kyphosis were recorded at baseline and after the treatment. For the per-protocol analysis, between-group differences at post-intervention were observed in maximum inspiratory pressure (19.77 cmH 2 O (11.49-28.04), P < .05; F = 22.436; P < .001; η 2 p  = 0.371) and forward head posture (-1.25 cm (-2.32 to -0.19), P < .05; F = 5.662; P = .022; η 2 p  = 0.13). The intention-to-treat analysis showed the same pattern of findings. The inspiratory muscle training combined with a manual therapy and therapeutic exercise program is more effective than its application in isolation for producing short-term maximum inspiratory pressure and forward head posture improvements in patients with asthma.

  5. Factors contributing to the failure of Humidified High-Flow Nasal Cannulae.

    PubMed

    Teoh, Sophia; Clyde, Elizabeth; Dassios, Theodore; Greenough, Anne

    2018-05-24

    The use of humidified high-flow nasal cannulae (HHFNC) as an alternative mode of non-invasive ventilation (NIV) in neonates has become widespread. A survey of UK neonatal units showed the proportion using HHFNC had increased from 56% in 2012 to 87% in 2015 (1). A recently reported Cochrane Review (2) comparing the use of HHFNC against other NIV modes of ventilation immediately after birth or following extubation showed no significant difference in the rates of bronchopulmonary dysplasia (BPD) or death and no significant difference in the rates of treatment failure/reintubation. Benefits cited include a significantly reduced risk of nasal trauma as compared to continuous positive airway pressure (CPAP). Furthermore, both medical staff and parents (3) were found to prefer HHFNC to CPAP. Identification of infants in whom use of HHFNC as either a primary or step-down mode of respiratory support may be inappropriate might further reduce the failure rate of HHFNC. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Inspiratory muscle training in quadriplegic patients.

    PubMed

    Silveira, Janne Marques; Gastaldi, Ada Clarice; Boaventura, Cristina de Matos; Souza, Hugo Celso

    2010-01-01

    To determine whether inspiratory muscle training can increase strength and endurance of these muscles in quadriplegic patients. Eight quadriplegic patients (7 males and 1 female) with injury to the lower cervical spine (segments C4-C7) were submitted to inspiratory muscle training with a threshold inspiratory muscle trainer adjusted to 30% of MIP. The training sessions were carried out with the patients in a sitting position, 5 days a week for 8 weeks. Endurance time, MIP, MEP and FVC were determined at baseline, week 4 and week 8. In comparison with the mean baseline value, there was an increase in MIP, measured in the sitting position, at weeks 4 and 8 (-83.0 +/- 18.9 cmH2O vs. -104.0 +/- 19.4 cmH2O and -111.3 +/- 22.7 cmH2O). There was an increase in MEP, also in the sitting position, at week 4 (from 36.8 +/- 8.1 to 42.6 +/- 8.8 cmH2O). There was an improvement in FVC at week 4 (from 2.1 +/- 0.8 to 2.5 +/- 0.6 L, representing an increase of 24 +/- 22%). Although there was an increase in endurance (sitting) at week 8, the difference was not significant in comparison with the baseline value (29.8 +/- 21.0 vs. 35.9 +/- 15.5 min, an increase of 173 +/- 233%). Quadriplegic patients can benefit from training at low loads (30% of MIP), which can improve inspiratory muscle strength, FVC and expiratory muscle performance.

  7. The fluid dynamics of canine olfaction: unique nasal airflow patterns as an explanation of macrosmia

    PubMed Central

    Craven, Brent A.; Paterson, Eric G.; Settles, Gary S.

    2010-01-01

    The canine nasal cavity contains hundreds of millions of sensory neurons, located in the olfactory epithelium that lines convoluted nasal turbinates recessed in the rear of the nose. Traditional explanations for canine olfactory acuity, which include large sensory organ size and receptor gene repertoire, overlook the fluid dynamics of odorant transport during sniffing. But odorant transport to the sensory part of the nose is the first critical step in olfaction. Here we report new experimental data on canine sniffing and demonstrate allometric scaling of sniff frequency, inspiratory airflow rate and tidal volume with body mass. Next, a computational fluid dynamics simulation of airflow in an anatomically accurate three-dimensional model of the canine nasal cavity, reconstructed from high-resolution magnetic resonance imaging scans, reveals that, during sniffing, spatially separate odour samples are acquired by each nostril that may be used for bilateral stimulus intensity comparison and odour source localization. Inside the nose, the computation shows that a unique nasal airflow pattern develops during sniffing, which is optimized for odorant transport to the olfactory part of the nose. These results contrast sharply with nasal airflow in the human. We propose that mammalian olfactory function and acuity may largely depend on odorant transport by nasal airflow patterns resulting from either the presence of a highly developed olfactory recess (in macrosmats such as the canine) or the lack of one (in microsmats including humans). PMID:20007171

  8. Common drive to the upper airway muscle genioglossus during inspiratory loading

    PubMed Central

    Woods, Michael J.; Nicholas, Christian L.; Semmler, John G.; Chan, Julia K. M.; Jordan, Amy S.

    2015-01-01

    Common drive is thought to constitute a central mechanism by which the efficiency of a motor neuron pool is increased. This study tested the hypothesis that common drive to the upper airway muscle genioglossus (GG) would increase with increased respiratory drive in response to an inspiratory load. Respiration, GG electromyographic (EMG) activity, single-motor unit activity, and coherence in the 0–5 Hz range between pairs of GG motor units were assessed for the 30 s before an inspiratory load, the first and second 30 s of the load, and the 30 s after the load. Twelve of twenty young, healthy male subjects provided usable data, yielding 77 pairs of motor units: 2 Inspiratory Phasic, 39 Inspiratory Tonic, 15 Expiratory Tonic, and 21 Tonic. Respiratory and GG inspiratory activity significantly increased during the loads and returned to preload levels during the postload periods (all showed significant quadratic functions over load trials, P < 0.05). As hypothesized, common drive increased during the load in inspiratory modulated motor units to a greater extent than in expiratory/tonic motor units (significant load × discharge pattern interaction, P < 0.05). Furthermore, this effect persisted during the postload period. In conclusion, common drive to inspiratory modulated motor units was elevated in response to increased respiratory drive. The postload elevation in common drive was suggestive of a poststimulus activation effect. PMID:26378207

  9. Mechanics of airflow in the human nasal airways.

    PubMed

    Doorly, D J; Taylor, D J; Schroter, R C

    2008-11-30

    The mechanics of airflow in the human nasal airways is reviewed, drawing on the findings of experimental and computational model studies. Modelling inevitably requires simplifications and assumptions, particularly given the complexity of the nasal airways. The processes entailed in modelling the nasal airways (from defining the model, to its production and, finally, validating the results) is critically examined, both for physical models and for computational simulations. Uncertainty still surrounds the appropriateness of the various assumptions made in modelling, particularly with regard to the nature of flow. New results are presented in which high-speed particle image velocimetry (PIV) and direct numerical simulation are applied to investigate the development of flow instability in the nasal cavity. These illustrate some of the improved capabilities afforded by technological developments for future model studies. The need for further improvements in characterising airway geometry and flow together with promising new methods are briefly discussed.

  10. Efficacy of high-flow oxygen by nasal cannula with active humidification in a patient with acute respiratory failure of neuromuscular origin.

    PubMed

    Díaz-Lobato, Salvador; Folgado, Miguel Angel; Chapa, Angel; Mayoralas Alises, Sagrario

    2013-12-01

    The treatment of choice for patients with respiratory failure of neuromuscular origin, especially in patients with hypercapnic respiratory acidosis, is noninvasive ventilation (NIV). Endotracheal intubation and invasive ventilation are indicated for patients with severe respiratory compromise or failure of NIV. In recent years, high-flow oxygen therapy and active humidification devices have been introduced, and emerging evidence suggests that high-flow oxygen may be effective in various clinical settings, such as acute respiratory failure, after cardiac surgery, during sedation and analgesia, in acute heart failure, in hypoxemic respiratory distress, in do-not-intubate patients, in patients with chronic cough and copious secretions, pulmonary fibrosis, or cancer, in critical areas and the emergency department. We report on a patient with amyotrophic lateral sclerosis who arrived at the emergency department with acute hypercapnic respiratory failure. She did not tolerate NIV and refused intubation, but was treated successfully with heated, humidified oxygen via high-flow nasal cannula. Arterial blood analysis after an hour on high-flow nasal cannula showed improved pH, P(aCO2), and awareness. The respiratory acidosis was corrected, and she was discharged after 5 days of hospitalization. Her response to high-flow nasal cannula was similar to that expected with NIV. We discuss the mechanisms of action of heated, humidified high-flow oxygen therapy.

  11. Topical nasal decongestant oxymetazoline (0.05%) provides relief of nasal symptoms for 12 hours.

    PubMed

    Druce, H M; Ramsey, D L; Karnati, S; Carr, A N

    2018-05-22

    Nasal congestion, often referred to as stuffy nose or blocked nose is one of the most prevalent and bothersome symptoms of an upper respiratory tract infection. Oxymetazoline, a widely used intranasal decongestant, offers fast symptom relief, but little is known about the duration of effect. The results of 2 randomized, double-blind, vehicle-controlled, single-dose, parallel, clinical studies (Study 1, n=67; Study 2, n=61) in which the efficacy of an oxymetazoline (0.05% Oxy) nasal spray in patients with acute coryzal rhinitis was assessed over a 12-hour time-period. Data were collected on both subjective relief of nasal congestion (6-point nasal congestion scale) and objective measures of nasal patency (anterior rhinomanometry) in both studies. A pooled study analysis showed statistically significant changes from baseline in subjective nasal congestion for 0.05% oxymetazoline and vehicle at each hourly time-point from Hour 1 through Hour 12 (marginally significant at Hour 11). An objective measure of nasal flow was statistically significant at each time-point up to 12 hours. Adverse events on either treatment were infrequent. The number of subjects who achieved an improvement in subjective nasal congestion scores of at least 1.0 was significantly higher in the Oxy group vs. vehicle at all hourly time-points on a 6-point nasal congestion scale. This study shows for the first time, that oxymetazoline provides both statistically significant and clinically meaningful relief of nasal congestion and improves nasal airflow for up to 12 hours following a single dose.

  12. Response characteristics for thermal and pressure devices commonly used for monitoring nasal and oral airflow during sleep studies.

    PubMed

    Gehring, J M; Cho, J-G; Wheatley, J R; Amis, T C

    2014-03-01

    We examined thermocouple and pressure cannulae responses to oral and nasal airflow using a polyester model of a human face, with patent nasal and oral orifices instrumented with a dual thermocouple (F-ONT2A, Grass) or a dual cannula (0588, Braebon) pressure transducer (± 10 cm H2O, Celesco) system. Tidal airflow was generated using a dual compartment facemask with pneumotachographs (Fleisch 2) connected to the model orifices. During nasal breathing: thermocouple amplitude = 0.38 Ln [pneumotachograph amplitude] + 1.31 and pressure cannula amplitude = 0.93 [pneumotachograph amplitude](2.15); during oral breathing: thermocouple amplitude = 0.44 Ln [pneumotachograph amplitude] + 1.07 and pressure cannula amplitude = 0.33 [pneumotachograph amplitude](1.72); (all range ∼ 0.1-∼ 4.0 L s(-1); r(2) > 0.7). For pneumotachograph amplitudes <1 L s(-1) (linear model) change in thermocouple amplitude/unit change in pneumotachograph amplitude was similar for nasal and oral airflow, whereas nasal pressure cannula amplitude/unit change in pneumotachograph amplitude was almost four times that for oral. Increasing oral orifice area from 0.33 cm(2) to 2.15 cm(2) increased oral thermocouple amplitude/unit change in pneumotachograph amplitude by ∼ 58% but decreased pressure cannula amplitude/unit change in pneumotachograph amplitude by 49%. For pneumotachograph amplitudes up to 1 L s(-1), alterations in inspiratory/expiratory ratios or total respiratory time did not affect the sensitivity of either nasal or oral pressure cannulae or the nasal thermocouple, but the oral thermocouple sensitivity was influenced by respiratory cycle time. Different nasal and oral responses influence the ability of these systems to quantitatively assess nasal and oral airflow and oro-nasal airflow partitioning.

  13. Inspiratory muscle training in patients with chronic obstructive pulmonary disease: structural adaptation and physiologic outcomes.

    PubMed

    Ramirez-Sarmiento, Alba; Orozco-Levi, Mauricio; Guell, Rosa; Barreiro, Esther; Hernandez, Nuria; Mota, Susana; Sangenis, Merce; Broquetas, Joan M; Casan, Pere; Gea, Joaquim

    2002-12-01

    The present study was aimed at evaluating the effects of a specific inspiratory muscle training protocol on the structure of inspiratory muscles in patients with chronic obstructive pulmonary disease. Fourteen patients (males, FEV1, 24 +/- 7% predicted) were randomized to either inspiratory muscle or sham training groups. Supervised breathing using a threshold inspiratory device was performed 30 minutes per day, five times a week, for 5 consecutive weeks. The inspiratory training group was subjected to inspiratory loading equivalent to 40 to 50% of their maximal inspiratory pressure. Biopsies from external intercostal muscles and vastus lateralis (control muscle) were taken before and after the training period. Muscle samples were processed for morphometric analyses using monoclonal antibodies against myosin heavy chain isoforms I and II. Increases in both the strength and endurance of the inspiratory muscles were observed in the inspiratory training group. This improvement was associated with increases in the proportion of type I fibers (by approximately 38%, p < 0.05) and in the size of type II fibers (by approximately 21%, p < 0.05) in the external intercostal muscles. No changes were observed in the control muscle. The study demonstrates that inspiratory training induces a specific functional improvement of the inspiratory muscles and adaptive changes in the structure of external intercostal muscles.

  14. High-flow nasal cannula therapy for adult patients

    PubMed Central

    Zhang, Jian; Lin, Ling; Pan, Konghan; Zhou, Jiancang

    2016-01-01

    High-flow nasal cannula (HFNC) oxygen therapy has several physiological advantages over traditional oxygen therapy devices, including decreased nasopharyngeal resistance, washing out of the nasopharyngeal dead space, generation of positive pressure in the pharynx, increasing alveolar recruitment in the lungs, humidification of the airways, increased fraction of inspired oxygen and improved mucociliary clearance. Recently, the use of HFNC in treating adult critical illness patients has significantly increased, and it is now being used in many patients with a range of different disease conditions. However, there are no established guidelines to direct the safe and effective use of HFNC for these patients. This review article summarizes the available published literature on the positive physiological effects, mechanisms of action, and the clinical applications of HFNC, compared with traditional oxygen therapy devices. The available literature suggests that HFNC oxygen therapy is an effective modality for the early treatment of critically adult patients. PMID:27698207

  15. Delayed Onset Muscle Soreness After Inspiratory Threshold Loading in Healthy Adults

    PubMed Central

    Mathur, Sunita; Sheel, A. William; Road, Jeremy D.; Reid, W. Darlene

    2010-01-01

    Purpose: Skeletal muscle damage occurs following high-intensity or unaccustomed exercise; however, it is difficult to monitor damage to the respiratory muscles, particularly in humans. The aim of this study was to use clinical measures to investigate the presence of skeletal muscle damage in the inspiratory muscles. Methods: Ten healthy subjects underwent 60 minutes of voluntary inspiratory threshold loading (ITL) at 70% of maximal inspiratory pressure. Maximal inspiratory and expiratory mouth pressures, delayed onset muscle soreness on a visual analogue scale and plasma creatine kinase were measured prior to ITL, and at repeated time points after ITL (4, 24 and 48 hours post-ITL). Results: Delayed onset muscle soreness was present in all subjects 24 hours following ITL (intensity = 22 ± 6 mm; significantly higher than baseline p = 0.02). Muscle soreness was reported primarily in the anterior neck region, and was correlated to the amount of work done by the inspiratory muscles during ITL (r = 0.72, p = 0.02). However, no significant change was observed in maximal inspiratory or expiratory pressures or creatine kinase. Conclusions: These findings suggest that an intense bout of ITL results in muscle soreness primarily in the accessory muscles of inspiration, however, may be insufficient to cause significant muscle damage in healthy adults. PMID:20467514

  16. Impact of High-Flow Nasal Cannula Use on Neonatal Respiratory Support Patterns and Length of Stay.

    PubMed

    Hoffman, Suma B; Terrell, Natalie; Driscoll, Colleen Hughes; Davis, Natalie L

    2016-10-01

    Heated humidified high-flow nasal cannula (HFNC) is thought to be comparable with nasal CPAP. The effect of multimodality mid-level respiratory support use in the neonatal ICU is unknown. The objective of this work was to evaluate the effect of introducing HFNC on length of respiratory support and stay. A chart review was conducted on subjects at 24-32 weeks gestation requiring mid-level support (HFNC/nasal CPAP) 1 y before and after HFNC implementation. The 2 groups were compared for clinical and demographic data using t test or chi-square analysis. Further, multivariate linear and logistic regression was done to determine significant risk factors for outcomes controlling for covariates. Eighty subjects were eligible in the pre-HFNC group, and 83 were eligible in the post-HFNC group. Subjects were similar in their baseline characteristics. In clinical outcomes, the post-HFNC group had higher rates of retinopathy of prematurity (P = .02) and a trend toward higher bronchopulmonary dysplasia rates (P = .063). The post-HFNC subjects had longer duration of mid-level support and were older at the time they were weaned to stable low-flow nasal cannula (P < .05). Although the length of respiratory support and stay and corrected gestational age at discharge were similar, those in the pre-HFNC period were more likely to be receiving full oral feeds and be discharged home versus being transferred to an intermediate care facility (P < .05). HFNC introduction was significantly associated with a longer duration of mid-level respiratory support, decrease in oral feeding at discharge, increased retinopathy of prematurity rates, and higher use of intermediate care facilities, leading us to examine our noninvasive ventilation and weaning strategies. Copyright © 2016 by Daedalus Enterprises.

  17. Discharge Identity of Medullary Inspiratory Neurons is Altered during Repetitive Fictive Cough

    PubMed Central

    Segers, L. S.; Nuding, S. C.; Vovk, A.; Pitts, T.; Baekey, D. M.; O’Connor, R.; Morris, K. F.; Lindsey, B. G.; Shannon, R.; Bolser, Donald C.

    2012-01-01

    This study investigated the stability of the discharge identity of inspiratory decrementing (I-Dec) and augmenting (I-Aug) neurons in the caudal (cVRC) and rostral (rVRC) ventral respiratory column during repetitive fictive cough in the cat. Inspiratory neurons in the cVRC (n = 23) and rVRC (n = 17) were recorded with microelectrodes. Fictive cough was elicited by mechanical stimulation of the intrathoracic trachea. Approximately 43% (10 of 23) of I-Dec neurons shifted to an augmenting discharge pattern during the first cough cycle (C1). By the second cough cycle (C2), half of these returned to a decrementing pattern. Approximately 94% (16 of 17) of I-Aug neurons retained an augmenting pattern during C1 of a multi-cough response episode. Phrenic burst amplitude and inspiratory duration increased during C1, but decreased with each subsequent cough in a series of repetitive coughs. As a step in evaluating the model-driven hypothesis that VRC I-Dec neurons contribute to the augmentation of inspiratory drive during cough via inhibition of VRC tonic expiratory neurons that inhibit premotor inspiratory neurons, cross-correlation analysis was used to assess relationships of tonic expiratory cells with simultaneously recorded inspiratory neurons. Our results suggest that reconfiguration of inspiratory-related sub-networks of the respiratory pattern generator occurs on a cycle-by-cycle basis during repetitive coughing. PMID:22754536

  18. Detection of flow limitation in obstructive sleep apnea with an artificial neural network.

    PubMed

    Norman, Robert G; Rapoport, David M; Ayappa, Indu

    2007-09-01

    During sleep, the development of a plateau on the inspiratory airflow/time contour provides a non-invasive indicator of airway collapsibility. Humans recognize this abnormal contour easily, and this study replicates this with an artificial neural network (ANN) using a normalized shape. Five 10 min segments were selected from each of 18 sleep records (respiratory airflow measured with a nasal cannula) with varying degrees of sleep disordered breathing. Each breath was visually scored for shape, and breaths split randomly into a training and test set. Equally spaced, peak amplitude normalized flow values (representing breath shape) formed the only input to a back propagation ANN. Following training, breath-by-breath agreement of the ANN with the manual classification was tabulated for the training and test sets separately. Agreement of the ANN was 89% in the training set and 70.6% in the test set. When the categories of 'probably normal' and 'normal', and 'probably flow limited' and 'flow limited' were combined, the agreement increased to 92.7% and 89.4% respectively, similar to the intra- and inter-rater agreements obtained by a visual classification of these breaths. On a naive dataset, the agreement of the ANN to visual classification was 57.7% overall and 82.4% when the categories were collapsed. A neural network based only on the shape of inspiratory airflow succeeded in classifying breaths as to the presence/absence of flow limitation. This approach could be used to provide a standardized, reproducible and automated means of detecting elevated upper airway resistance.

  19. Post-extubation atelectasis in newborns with surgical diseases: a report of two cases involving the use of a high-flow nasal cannula.

    PubMed

    de Paula, Lúcia Cândida Soares; Siqueira, Fernanda Corsante; Juliani, Regina Célia Turola Passos; de Carvalho, Werther Brunow; Ceccon, Maria Esther Jurfest Rivero; Tannuri, Uenis

    2014-01-01

    Atelectasis is a pulmonary disorder that lengthens the hospitalization time of newborns in intensive care units, resulting in increased morbidity among these infants. High-flow nasal cannulae have been used in newborns to prevent atelectasis and/or expand pulmonary regions affected by atelectasis; however, to date, no evidence-based data regarding this approach have been reported. In this paper, we report on the cases of two male newborn patients. The first and second patients described in this report were hospitalized for a neurosurgical procedure and the treatment of abdominal disease, respectively, and were subjected to invasive mechanical ventilation for 4 and 36 days, respectively. After extubation, these patients continued receiving oxygen therapy but experienced clinical and radiological worsening typical of atelectasis. In both cases, by 24 hours after the implantation of an high-flow nasal cannulae to provide noninvasive support, radiological examinations revealed the complete resolution of atelectasis. In these cases, the use of an high-flow nasal cannulae was effective in reversing atelectasis. Thus, this approach may be utilized as a supplemental noninvasive ventilatory therapy to avoid unnecessary intubation.

  20. The effect of the inspiratory muscle training on functional ability in stroke patients.

    PubMed

    Jung, Nam-Jin; Na, Sang-Su; Kim, Seung-Kyu; Hwangbo, Gak

    2017-11-01

    [Purpose] This study was to find out an inspiratory muscle training (IMT) program therapeutic effects on stroke patients' functional ability. [Subjects and Methods] Twenty stroke patients were assigned to one of two groups: inspiratory muscle training (n=10), and control (n=10), randomization. The inspiratory muscle training participants undertook an exercise program for 30 minute per times, 5 times a week for 6 weeks. The investigator measured the patients' trunk impairment scale (TIS) and 6 minute walking test (6MW) for functional ability before and after IMT. [Results] The TIS appeared some significant differences in both groups before and after the training. The 6MW test showed some significant differences in the inspiratory muscle training group, but didn't show any significant difference in the control group. And the differences in both groups after depending the inspiratory muscle training were significantly found in the tests of TIS and 6MW test [Conclusion] The results showed that the inspiratory muscle training in stroke patients are correlated with the trunk stability and locomotion ability, suggesting that physical therapist must take into consideration the inspiratory muscle training, as well as functional training to improve physical function in stroke patients.

  1. Differential impact of flow and mouth leak on oropharyngeal humidification during high-flow nasal cannula: a neonatal bench study.

    PubMed

    Ullrich, Tim Leon; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik Stefan

    2018-06-01

    Heated humidification is paramount during neonatal high-flow nasal cannula (HFNC) therapy. However, there is little knowledge about the influence of flow rate and mouth leak on oropharyngeal humidification and temperature. The effect of the Optiflow HFNC on oropharyngeal gas conditioning was investigated at flow rates of 4, 6 and 8 L min -1 with and without mouth leak in a bench model simulating physiological oropharyngeal air conditions during spontaneous breathing. Temperature and absolute humidity (AH) were measured using a digital thermo-hygrosensor. Without mouth leak, oropharyngeal temperature and AH increased significantly with increasing flow (P < 0.001). Mouth leak did not affect this increase up to 6 L min -1 , but at 8 L min -1 , temperature and AH plateaued, and the effect of mouth leak became statistically significant (P < 0.001). Mouth leak during HFNC had a negative impact on oropharyngeal gas conditioning when high flows were applied. However, temperature and AH always remained clinically acceptable.

  2. Effect of Ambient Ozone Exposure Assessed by Individual Monitors on Nasal Function and Exhaled NO Among School Children in the Area of Thessaloniki, Greece.

    PubMed

    Angelis, Nikolaos; Spyratos, Dionisios; Domvri, Kalliopi; Dimakopoulou, Konstantina; Samoli, Evangelia; Kalamaras, Georgios; Karakatsani, Anna; Grivas, Georgios; Katsouyanni, Klea; Papakosta, Despina

    2017-06-01

    The study of short-term effects of environmental ozone exposure on nasal airflow, lung function, and airway inflammation. Ninety one children-47 underwent rhinomanometry-were included. The study was carried out during the 2013 to 2014 academic year. Activity questionnaires and personal O3 samplers were distributed and 1 week later, respiratory measurements were performed. Daily measurements of outdoor ozone were also considered. A 10 μg/m increase in weekly personal ozone exposure concentrations was associated with a non-statistically significant 12.7% decrease in nasal inspiratory airflow (29.4% during the high ozone period). When the outdoor exposure of the same and the previous day were taken into account the corresponding figures were 13.48% and 43.58% (P = 0.02). There is an indication for increased risk of nasal obstruction during exposure to high ozone.

  3. Effects of hypercapnia and hypoxia on nasal vasculature and airflow resistance in the anaesthetized dog.

    PubMed Central

    Lung, M A; Wang, J C

    1986-01-01

    The experiments were performed on anaesthetized dogs which breathed spontaneously or were artificially ventilated and paralysed. The spontaneous nasal arterial blood flow was measured on one side of the nose while nasal vascular resistance was determined on the other side simultaneously. Nasal arterial blood flow was measured by means of an electromagnetic flow sensor placed around the terminal branch of the internal maxillary artery, the main arterial supply to the nasal mucosa. Nasal vascular resistance was measured by constant-flow perfusion of the terminal branch of the internal maxillary artery. Nasal airway resistance was assessed by monitoring the transnasal pressure at constant airflow through each side of the nose simultaneously. Hypercapnic gas challenge (8% CO2, 30% O2 in N2) to the lungs increased nasal vascular resistance and decreased nasal airway resistance. Similar gas challenge to the nose did not affect nasal vascular resistance but decreased nasal airway resistance. Hypoxic gas challenge (6% O2 in N2) to the lungs did not affect the nasal vascular resistance but decreased nasal airway resistance only when the nasal vascular bed was under controlled perfusion. Similar gas challenge to the nose did not affect either nasal vascular or airway resistance. Arterial chemoreceptor stimulation by intracarotid injection of sodium cyanide increased nasal vascular resistance and decreased nasal airway resistance. The nasal vascular response to hypercapnia and arterial chemoreceptor stimulation was reflex in nature, being abolished by nasal sympathectomy. The nasal airway response to hypercapnia, hypoxia and arterial chemoreceptor stimulation was reflex in nature, being partially or completely abolished by nasal sympathectomy. Hypercapnia probably induced a local vasodilatatory effect on the capacitance vessels whereas hypoxia had no direct action on the vasculature. PMID:3091811

  4. "Functional" Inspiratory and Core Muscle Training Enhances Running Performance and Economy.

    PubMed

    Tong, Tomas K; McConnell, Alison K; Lin, Hua; Nie, Jinlei; Zhang, Haifeng; Wang, Jiayuan

    2016-10-01

    Tong, TK, McConnell, AK, Lin, H, Nie, J, Zhang, H, and Wang, J. "Functional" inspiratory and core muscle training enhances running performance and economy. J Strength Cond Res 30(10): 2942-2951, 2016-We compared the effects of two 6-week high-intensity interval training interventions. Under the control condition (CON), only interval training was undertaken, whereas under the intervention condition (ICT), interval training sessions were followed immediately by core training, which was combined with simultaneous inspiratory muscle training (IMT)-"functional" IMT. Sixteen recreational runners were allocated to either ICT or CON groups. Before the intervention phase, both groups undertook a 4-week program of "foundation" IMT to control for the known ergogenic effect of IMT (30 inspiratory efforts at 50% maximal static inspiratory pressure [P0] per set, 2 sets per day, 6 days per week). The subsequent 6-week interval running training phase consisted of 3-4 sessions per week. In addition, the ICT group undertook 4 inspiratory-loaded core exercises (10 repetitions per set, 2 sets per day, inspiratory load set at 50% post-IMT P0) immediately after each interval training session. The CON group received neither core training nor functional IMT. After the intervention phase, global inspiratory and core muscle functions increased in both groups (p ≤ 0.05), as evidenced by P0 and a sport-specific endurance plank test (SEPT) performance, respectively. Compared with CON, the ICT group showed larger improvements in SEPT, running economy at the speed of the onset of blood lactate accumulation, and 1-hour running performance (3.04% vs. 1.57%, p ≤ 0.05). The changes in these variables were interindividually correlated (r ≥ 0.57, n = 16, p ≤ 0.05). Such findings suggest that the addition of inspiratory-loaded core conditioning into a high-intensity interval training program augments the influence of the interval program on endurance running performance and that this may be

  5. Inspiratory muscle training in bronchiectasis patients: a prospective randomized controlled study.

    PubMed

    Liaw, Mei-Yun; Wang, Yi-Hsi; Tsai, Yu-Chin; Huang, Kuo-Tung; Chang, Pei-Wen; Chen, Yung-Che; Lin, Meng-Chih

    2011-06-01

    To investigate the efficacy and feasibility of home-based inspiratory muscle training in patients with bronchiectasis. A prospective, single-blind, randomized, controlled study. Outpatient clinic of a tertiary care medical centre. Twenty-six patients with bronchiectasis were randomly divided into inspiratory muscle training and control groups. In the inspiratory muscle training group (n = 13), the training programme started with an intensity of 30% maximal inspiratory pressure (MIP), which was increased by 2 cmH(2)O each week, for 30 minutes daily, 5 days a week for eight weeks. The control group (n = 13) did not receive inspiratory muscle training. Main outcome measures included spirometry, resting oxyhaemoglobin saturation by pulse oximetry (SpO(2)), lowest SpO(2) and Borg Scale during 6-minute walking tests, 6-minute walking distance (6MWD), 6-minute walking work (6M(work)), MIP, maximal expiratory pressure (MEP) and St George's Respiratory Questionnaire. There were significant differences in change from baseline in 6MWD (411.9 (133.5) vs. 473.2 (117.2) m, P = 0.021), 6M(work) (21 051.0 (8286.7) vs. 23 915.5 (8343.0) kg-m, P = 0.022), MIP (60.8 (21.8) vs. 84.6 (29.0) cmH(2)O, P = 0.004), and MEP (72.3 (31.1) vs. 104.2 (35.7) cmH(2)O, P = 0.004) in the inspiratory muscle training group. Significant improvements in both MIP (23.8 (25.3) vs. 2.3 (16.4) cmH(2)O, adjusted P-value = 0.005) and MEP (31.9 (30.8) vs. 11.5 (20.8) cmH(2)O, adjusted P-value = 0.038) levels after adjusting for age by linear regression analysis were observed between groups. An eight-week home-based inspiratory muscle training is feasible and effective in improving both inspiratory and expiratory muscle strength, but has no effect on respiratory function and quality of life in patients with bronchiectasis.

  6. Computed Intranasal Spray Penetration: Comparisons Before and After Nasal Surgery

    PubMed Central

    Frank, Dennis O.; Kimbell, Julia S.; Cannon, Daniel; Rhee, John S.

    2012-01-01

    Background Quantitative methods for comparing intranasal drug delivery efficiencies pre- and postoperatively have not been fully utilized. The objective of this study is to use computational fluid dynamics techniques to evaluate aqueous nasal spray penetration efficiencies before and after surgical correction of intranasal anatomic deformities. Methods Ten three-dimensional models of the nasal cavities were created from pre- and postoperative computed tomography scans in five subjects. Spray simulations were conducted using a particle size distribution ranging from 10–110μm, a spray speed of 3m/s, plume angle of 68°, and with steady state, resting inspiratory airflow present. Two different nozzle positions were compared. Statistical analysis was conducted using Student T-test for matched pairs. Results On the obstructed side, posterior particle deposition after surgery increased by 118% and was statistically significant (p-value=0.036), while anterior particle deposition decreased by 13% and was also statistically significant (p-value=0.020). The fraction of particles that by-passed the airways either pre- or post-operatively was less than 5%. Posterior particle deposition differences between obstructed and contralateral sides of the airways were 113% and 30% for pre- and post-surgery, respectively. Results showed that nozzle positions can influence spray delivery. Conclusions Simulations predicted that surgical correction of nasal anatomic deformities can improve spray penetration to areas where medications can have greater effect. Particle deposition patterns between both sides of the airways are more evenly distributed after surgery. These findings suggest that correcting anatomic deformities may improve intranasal medication delivery. For enhanced particle penetration, patients with nasal deformities may explore different nozzle positions. PMID:22927179

  7. Effect on lung function of continuous positive airway pressure administered either by infant flow driver or a single nasal prong.

    PubMed

    Kavvadia, V; Greenough, A; Dimitriou, G

    2000-04-01

    The aim of this study was to assess if continuous positive airways pressure (CPAP) delivered by an infant flow driver (IFD) was a more effective method of improving lung function than delivering CPAP by a single nasal prong. A total of 36 infants (median gestational age 29 weeks, range 25-35 weeks) were studied, 12 who received CPAP via an IFD, 12 who received CPAP via a single nasal prong and 12 without CPAP. CPAP was administered post extubation if apnoeas and bradycardias or a respiratory acidosis developed or electively if the infant was of birth weight <1.0 kg. Lung function was assessed by the supplementary oxygen requirement and measurement of compliance of the respiratory system using an occlusion technique. Assessments were made immediately prior to and after 24 h of CPAP administration and at similar postnatal ages in the non-CPAP group. The infants who did not require CPAP had better lung function (non significant) than the other two groups before they received CPAP. After 24 h, lung function had improved in both CPAP groups to the level of the non CPAP infants. The supplementary oxygen requirements of all three groups decreased over the 24 h period, but this only reached significance in the single nasal prong group (P<0.05). Four infants supported by the IFD, but none with a single nasal prong, became hyperoxic. Continuous positive airways pressure administration via the infant flow driver appears to offer no short-term advantage over a single nasal prong system when used after extubation in preterm infants.

  8. Shape of the human nasal cavity promotes retronasal smell

    NASA Astrophysics Data System (ADS)

    Trastour, Sophie; Melchionna, Simone; Mishra, Shruti; Zwicker, David; Lieberman, Daniel E.; Kaxiras, Efthimios; Brenner, Michael P.

    2015-11-01

    Humans are exceptionally good at perceiving the flavor of food. Flavor includes sensory input from taste receptors but is dominated by olfactory (smell) receptors. To smell food while eating, odors must be transported to the nasal cavity during exhalation. Olfactory performance of this retronasal route depends, among other factors, on the position of the olfactory receptors and the shape of the nasal cavity. One biological hypothesis is that the derived configuration of the human nasal cavity has resulted in a greater capacity for retronasal smell, hence enhanced flavor perception. We here study the air flow and resulting odor deposition as a function of the nasal geometry and the parameters of exhalation. We perform computational fluid dynamics simulations in realistic geometries obtained from CT scans of humans. Using the resulting flow fields, we then study the deposition of tracer particles in the nasal cavity. Additionally, we derive scaling laws for the odor deposition rate as a function of flow parameters and geometry using boundary layer theory. These results allow us to assess which changes in the evolution of the human nose led to significant improvements of retronasal smell.

  9. Influence of inspiratory resistive loading on expiratory muscle fatigue in healthy humans.

    PubMed

    Peters, Carli M; Welch, Joseph F; Dominelli, Paolo B; Molgat-Seon, Yannick; Romer, Lee M; McKenzie, Donald C; Sheel, A William

    2017-09-01

    What is the central question of this study? This study is the first to measure objectively both inspiratory and expiratory muscle fatigue after inspiratory resistive loading to determine whether the expiratory muscles are activated to the point of fatigue when specifically loading the inspiratory muscles. What is the main finding and its importance? The absence of abdominal muscle fatigue suggests that future studies attempting to understand the neural and circulatory consequences of diaphragm fatigue can use inspiratory resistive loading without considering the confounding effects of abdominal muscle fatigue. Expiratory resistive loading elicits inspiratory as well as expiratory muscle fatigue, suggesting parallel coactivation of the inspiratory muscles during expiration. It is unknown whether the expiratory muscles are likewise coactivated to the point of fatigue during inspiratory resistive loading (IRL). The purpose of this study was to determine whether IRL elicits expiratory as well as inspiratory muscle fatigue. Healthy male subjects (n = 9) underwent isocapnic IRL (60% maximal inspiratory pressure, 15 breaths min -1 , 0.7 inspiratory duty cycle) to task failure. Abdominal and diaphragm contractile function was assessed at baseline and at 3, 15 and 30 min post-IRL by measuring gastric twitch pressure (P ga,tw ) and transdiaphragmatic twitch pressure (P di,tw ) in response to potentiated magnetic stimulation of the thoracic and phrenic nerves, respectively. Fatigue was defined as a significant reduction from baseline in P ga,tw or P di,tw . Throughout IRL, there was a time-dependent increase in cardiac frequency and mean arterial blood pressure, suggesting activation of the respiratory muscle metaboreflex. The P di,tw was significantly lower than baseline (34.3 ± 9.6 cmH 2 O) at 3 (23.2 ± 5.7 cmH 2 O, P < 0.001), 15 (24.2 ± 5.1 cmH 2 O, P < 0.001) and 30 min post-IRL (26.3 ± 6.0 cmH 2 O, P < 0.001). The P ga,tw was not significantly

  10. Acute effects of inspiratory muscle warm-up on pulmonary function in healthy subjects.

    PubMed

    Özdal, Mustafa

    2016-06-15

    The acute effects of inspiratory muscle warm-up on pulmonary functions were examined in 26 healthy male subjects using the pulmonary function test (PFT) in three different trials. The control trial (CON) did not involve inspiratory muscle warm-up, while the placebo (IMWp) and experimental (IMW) trials involved inspiratory muscle warm-up. There were no significant changes between the IMWp and CON trials (p>0.05). All the PFT measurements, including slow vital capacity, inspiratory vital capacity, forced vital capacity, forced expiratory volume in one second, maximal voluntary ventilation, and maximal inspiratory pressure were significantly increased by 3.55%, 12.52%, 5.00%, 2.75%, 2.66%, and 7.03% respectively, in the subjects in the IMW trial than those in the CON trial (p<0.05). These results show that inspiratory muscle warm-up improved the pulmonary functions. The mechanisms responsible for these improvements are probably associated with the concomitant increase in the inspiratory muscle strength, and the cooperation of the upper thorax, neck, and respiratory muscles, and increased level of reactive O2 species in muscle tissue, and potentially improvement of muscle O2 delivery-to-utilization. However, further investigation is required to determine the precise mechanisms responsible from among these candidates. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Inspiratory muscle training to enhance recovery from mechanical ventilation: a randomised trial.

    PubMed

    Bissett, Bernie M; Leditschke, I Anne; Neeman, Teresa; Boots, Robert; Paratz, Jennifer

    2016-09-01

    In patients who have been mechanically ventilated, inspiratory muscles remain weak and fatigable following ventilatory weaning, which may contribute to dyspnoea and limited functional recovery. Inspiratory muscle training may improve inspiratory muscle strength and endurance following weaning, potentially improving dyspnoea and quality of life in this patient group. We conducted a randomised trial with assessor-blinding and intention-to-treat analysis. Following 48 hours of successful weaning, 70 participants (mechanically ventilated ≥7 days) were randomised to receive inspiratory muscle training once daily 5 days/week for 2 weeks in addition to usual care, or usual care (control). Primary endpoints were inspiratory muscle strength and fatigue resistance index (FRI) 2 weeks following enrolment. Secondary endpoints included dyspnoea, physical function and quality of life, post-intensive care length of stay and in-hospital mortality. 34 participants were randomly allocated to the training group and 36 to control. The training group demonstrated greater improvements in inspiratory strength (training: 17%, control: 6%, mean difference: 11%, p=0.02). There were no statistically significant differences in FRI (0.03 vs 0.02, p=0.81), physical function (0.25 vs 0.25, p=0.97) or dyspnoea (-0.5 vs 0.2, p=0.22). Improvement in quality of life was greater in the training group (14% vs 2%, mean difference 12%, p=0.03). In-hospital mortality was higher in the training group (4 vs 0, 12% vs 0%, p=0.051). Inspiratory muscle training following successful weaning increases inspiratory muscle strength and quality of life, but we cannot confidently rule out an associated increased risk of in-hospital mortality. ACTRN12610001089022, results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Pulse transit time as a measure of inspiratory effort in children.

    PubMed

    Pagani, Jacopo; Villa, Maria Pia; Calcagnini, Giovanni; Alterio, Arianna; Ambrosio, Rosa; Censi, Federica; Ronchetti, Roberto

    2003-10-01

    The current criterion standard for measuring inspiratory effort, esophageal manometry, is an invasive procedure that young patients find intolerable. Inspiratory effort can also be assessed noninvasively by measuring the pulse transit time (PTT). PTT is the time the pulse wave (PW) takes to travel between two arterial sites (normally heart to finger). The speed at which the PW travels is directly proportional to arterial BP. When BP rises, PTT shortens. Conversely, when BP falls, PTT lengthens. In this study, we investigated PTT as a measure for evaluating inspiratory effort in children. We studied 15 healthy children (age range, 5 to 12 years; mean age [+/- SD], 8.3 +/- 2.74; 9 male children) selected from patients referred to our pediatric center for routine assessment. We assessed changes in the PTT during breathing against known resistances in awake children. Resistance was applied to the nose and mouth with a modified, two-way, nonrebreathing facemask. Our data show a good correlation between the induced inspiratory effort and the amplitude of PTT variations. PTT should be a useful method for quantifying changes in inspiratory effort due to augmented upper airway resistance in awake children.

  13. Improvement of nasal breathing in cleft patients following midface osteotomy.

    PubMed

    Götzfried, H F; Masing, H

    1988-02-01

    In 20 adult cleft patients, the influence of a Le-Fort-I-osteotomy and ventral-caudal advancement of the maxilla on nasal breathing was studied. An increase of nasal air flow in the majority of patients is due to an increase in the volume of nasal skeleton and/or in the nasolabial angle and alar nasal base. Rhinomanometric measurements and X-ray examination confirm the results.

  14. [High-Flow Nasal Cannulae (HFNC) in Neonates: A Survey of Current Practice in Level 1 Perinatal Centres in the German State of North Rhine-Westphalia].

    PubMed

    Hepping, N; Garbe, W; Schneider, K

    2015-12-01

    High-flow nasal cannulae (HFNC) is a kind of non-invasive respiratory support. In recent years, its application has gained increasing popularity for treating neonates with respiratory failure. Within this study, neonatologists employed at high level perinatal centres within the region of North Rhine-Westphalia, Germany were interviewed. We evaluated their personal experience as well as the underlying indication for using HFNC. We undertook an online survey. 93% of the interviewed participants use HFNC systems in their NICU. The most prominent indications were CPAP-weaning, nasal trauma, and apnoea of prematurity. Both initial flow and maximum and minimum flow rates varied widely. The primary benefit of HFNC vs. conventional CPAP was the improved neonate tolerance, less nasal traumata and ease of application and care. A common disadvantage was the inability to conduct PEEP measurements. The application of the HFNC system is increasing for specific neonatal indications, thereby increasing the data for the evaluation of effectivity and safety. Nevertheless, detailed investigations of the appropriate flow rate settings are still lacking. © Georg Thieme Verlag KG Stuttgart · New York.

  15. The Relationship between High Flow Nasal Cannula Flow Rate and Effort of Breathing in Children.

    PubMed

    Weiler, Thomas; Kamerkar, Asavari; Hotz, Justin; Ross, Patrick A; Newth, Christopher J L; Khemani, Robinder G

    2017-10-01

    To use an objective metric of effort of breathing to determine optimal high flow nasal cannula (HFNC) flow rates in children <3 years of age. Single-center prospective trial in a 24-bed pediatric intensive care unit of children <3 years of age on HFNC. We measured the percent change in pressure∙rate product (PRP) (an objective measure of effort of breathing) as a function of weight-indexed flow rates of 0.5, 1.0, 1.5, and 2.0 L/kg/minute. For a subgroup of patients, 2 different HFNC delivery systems (Fisher & Paykel [Auckland, New Zealand] and Vapotherm [Exeter, New Hampshire]) were compared. Twenty-one patients (49 titration episodes) were studied. The most common diagnoses were bronchiolitis and pneumonia. Overall, there was a significant difference in the percent change in PRP from baseline (of 0.5 L/kg/minute) with increasing flow rates for the entire cohort (P < .001) with largest change at 2.0 L/kg/min (-21%). Subgroup analyses showed no significant difference in percent change in PRP from baseline when comparing the 2 different HFNC delivery systems (P = .12). Patients ≤8 kg experienced a larger percent change in PRP as HFNC flow rates were increased (P = .001) than patients >8 kg. The optimal HFNC flow rate to reduce effort of breathing in infants and young children is approximately 1.5-2.0 L/kg/minute with more benefit seen in children ≤8 kg. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Visualization and Quantification of Nasal and Olfactory Deposition in a Sectional Adult Nasal Airway Cast.

    PubMed

    Xi, Jinxiang; Yuan, Jiayao Eddie; Zhang, Yu; Nevorski, Dannielle; Wang, Zhaoxuan; Zhou, Yue

    2016-06-01

    To compare drug deposition in the nose and olfactory region with different nasal devices and administration techniques. A Sar-Gel based colorimetry method will be developed to quantify local deposition rates. A sectional nasal airway cast was developed based on an MRI-based nasal airway model to visualize deposition patterns and measure regional dosages. Four nasal spray pumps and four nebulizers were tested with both standard and point-release administration techniques. Delivered dosages were measured using a high-precision scale. The colorimetry correlation for deposited mass was developed via image processing in Matlab and its performance was evaluated through comparison to experimental measurements. Results show that the majority of nasal spray droplets deposited in the anterior nose while only a small fraction (less than 4.6%) reached the olfactory region. For all nebulizers considered, more droplets went beyond the nasal valve, leading to distinct deposition patterns as a function of both the nebulizer type (droplet size and initial speed) and inhalation flow rate. With the point-release administration, up to 9.0% (±1.9%) of administered drugs were delivered to the olfactory region and 15.7 (±2.4%) to the upper nose using Pari Sinus. Standard nasal devices are inadequate to deliver clinically significant olfactory dosages without excess drug losses in other nasal epitheliums. The Sar-Gel based colorimetry method appears to provide a simple and practical approach to visualize and quantify regional deposition.

  17. What is normal nasal airflow? A computational study of 22 healthy adults

    PubMed Central

    Zhao, Kai; Jiang, Jianbo

    2014-01-01

    Objective Nasal airflow is essential for functioning of the human nose. Given individual variation in nasal anatomy, there is yet no consensus what constitutes normal nasal airflow patterns. We attempt to obtain such information that is essential to differentiate disease-related variations. Methods Computational fluid dynamics (CFD) simulated nasal airflow in 22 healthy subjects during resting breathing. Streamline patterns, airflow distributions, velocity profiles, pressure, wall stress, turbulence, and vortical flow characteristics under quasi-steady state were analyzed. Patency ratings, acoustically measured minimum cross-sectional area (MCA), and rhinomanometric nasal resistance (NR) were examined for potential correlations with morphological and airflow-related variables. Results Common features across subjects included: >50% total pressure-drop reached near the inferior turbinate head; wall shear stress, NR, turbulence energy, and vorticity were lower in the turbinate than in the nasal valve region. However, location of the major flow path and coronal velocity distributions varied greatly across individuals. Surprisingly, on average, more flow passed through the middle than the inferior meatus and correlated with better patency ratings (r=-0.65, p<0.01). This middle flow percentage combined with peak post-vestibule nasal heat loss and MCA accounted for >70% of the variance in subjective patency ratings and predicted patency categories with 86% success. Nasal index correlated with forming of the anterior dorsal vortex. Expected for resting breathing, the functional impact for local and total turbulence, vorticity, and helicity was limited. As validation, rhinomanometric NR significantly correlated with CFD simulations (r=0.53, p<0.01). Conclusion Significant variations of nasal airflow found among healthy subjects; Key features may have clinically relevant applications. PMID:24664528

  18. Pretreatment Prediction of the Outcomes of Intranasal Steroid Sprays in Cases with Inferior Turbinate Hypertrophy.

    PubMed

    Karataş, Abdullah

    2017-09-01

    Intranasal steroid sprays (INSS) are frequently prescribed for treating inferior turbinate hypertrophy (ITH). Complications due to the long-term application of INSS such as crusting, epistaxis, nasal mucosa dryness, and septal perforation may occur. Predicting patients who would benefit from INSS early might lower treatment costs and complication rates. We examined the predictive value of nasal decongestant response rates for the outcomes of INSS in ITH. Fifty patients with bilateral ITH were included in two groups: patients benefiting from INSS and those not benefiting. Nasal airflow was assessed by peak nasal inspiratory flow (PNIF) measurement in all cases. Measurements were taken three times: before and after the application of nasal decongestant sprays and after the application of INSS. In both groups, the nasal air flow rates significantly increased after the application of nasal decongestant sprays; however, the nasal decongestant response rates were higher in the group with patients benefiting from INSS. There was a strong correlation between the nasal air flow rates measured after the application of nasal decongestant sprays and after the application of INSS. The cut-off value for the relationship between increased nasal air flow rates after the application of nasal decongestant sprays and outcomes of INSS was 23%. Measurement of nasal airflow increase rate after the application of nasal decongestant sprays is a simple and easy method for the early prediction of the outcomes of INSS in ITH. A higher than 23% increase in nasal air flow rates after the application of nasal decongestant sprays indicates much better outcomes of INSS for patients.

  19. Pretreatment Prediction of the Outcomes of Intranasal Steroid Sprays in Cases with Inferior Turbinate Hypertrophy

    PubMed Central

    Karataş, Abdullah

    2017-01-01

    Objective Intranasal steroid sprays (INSS) are frequently prescribed for treating inferior turbinate hypertrophy (ITH). Complications due to the long-term application of INSS such as crusting, epistaxis, nasal mucosa dryness, and septal perforation may occur. Predicting patients who would benefit from INSS early might lower treatment costs and complication rates. We examined the predictive value of nasal decongestant response rates for the outcomes of INSS in ITH. Methods Fifty patients with bilateral ITH were included in two groups: patients benefiting from INSS and those not benefiting. Nasal airflow was assessed by peak nasal inspiratory flow (PNIF) measurement in all cases. Measurements were taken three times: before and after the application of nasal decongestant sprays and after the application of INSS. Results In both groups, the nasal air flow rates significantly increased after the application of nasal decongestant sprays; however, the nasal decongestant response rates were higher in the group with patients benefiting from INSS. There was a strong correlation between the nasal air flow rates measured after the application of nasal decongestant sprays and after the application of INSS. The cut-off value for the relationship between increased nasal air flow rates after the application of nasal decongestant sprays and outcomes of INSS was 23%. Conclusion Measurement of nasal airflow increase rate after the application of nasal decongestant sprays is a simple and easy method for the early prediction of the outcomes of INSS in ITH. A higher than 23% increase in nasal air flow rates after the application of nasal decongestant sprays indicates much better outcomes of INSS for patients. PMID:29392066

  20. Flow Induced by Ex-Vivo Nasal Cilia: Developing an Index of Dyskinesis

    NASA Astrophysics Data System (ADS)

    Grotberg, James; Bottier, Mathieu; Pena-Fernandez, Marta; Blanchon, Sylvain; Pelle, Gabriel; Bequignon, Emilie; Isabey, Daniel; Coste, Andre; Escudier, Estelle; Papon, Jean-Francois; Filoche, Marcel; Louis, Bruno

    2017-11-01

    Mucociliary clearance is one of the major lines of defense of the respiratory system. The mucus layer coating the pulmonary airways is moved along and out of the lung by the activity of motile cilia, thus expelling the particles trapped in it. Here we compare ex vivomeasurements of a Newtonian flow induced by cilia beating (using micro-beads as tracers) and a mathematical model of this fluid flow. Samples of nasal epithelial cells placed in water are recorded by high-speed video-microscopy and ciliary beat pattern is inferred. Automatic tracking of micro-beads, used as markers of the flow generated by cilia motion, enables us also to assess the steady velocity profile as a function of the distance above the cilia. This profile is shown to be essentially parabolic. This compares well to a 2D mathematical model for ciliary fluid propulsion using an envelope model. From the model and the experimental measurements, the shear stress exerted by the cilia is deduced. Finally, this shear stress is proposed as a new index for characterizing the efficiency of ciliary beating and diagnosing dyskinesis.

  1. Effect of Very-High-Flow Nasal Therapy on Airway Pressure and End-Expiratory Lung Impedance in Healthy Volunteers.

    PubMed

    Parke, Rachael L; Bloch, Andreas; McGuinness, Shay P

    2015-10-01

    Previous research has demonstrated a positive linear correlation between flow delivered and airway pressure generated by high-flow nasal therapy. Current practice is to use flows over a range of 30-60 L/min; however, it is technically possible to apply higher flows. In this study, airway pressure measurements and electrical impedance tomography were used to assess the relationship between flows of up to 100 L/min and changes in lung physiology. Fifteen healthy volunteers were enrolled into this study. A high-flow nasal system capable of delivering a flow of 100 L/min was purpose-built using 2 Optiflow systems. Airway pressure was measured via the nasopharynx, and cumulative changes in end-expiratory lung impedance were recorded using the PulmoVista 500 system at gas flows of 30-100 L/min in increments of 10 L/min. The mean age of study participants was 31 (range 22-44) y, the mean ± SD height was 171.8 ± 7.5 cm, the mean ± SD weight was 69.7 ± 10 kg, and 47% were males. Flows ranged from 30 to 100 L/min with resulting mean ± SD airway pressures of 2.7 ± 0.7 to 11.9 ± 2.7 cm H2O. A cumulative and linear increase in end-expiratory lung impedance was observed with increasing flows, as well as a decrease in breathing frequency. Measured airway pressure and lung impedance increased linearly with increased gas flow. Observed airway pressures were in the range used clinically with face-mask noninvasive ventilation. Developments in delivery systems may result in this therapy being an acceptable alternative to face-mask noninvasive ventilation. Copyright © 2015 by Daedalus Enterprises.

  2. Effects of inspiratory muscle training on resistance to fatigue of respiratory muscles during exhaustive exercise.

    PubMed

    Segizbaeva, M O; Timofeev, N N; Donina, Zh A; Kur'yanovich, E N; Aleksandrova, N P

    2015-01-01

    The aim of this study was to assess the effect of inspiratory muscle training (IMT) on resistance to fatigue of the diaphragm (D), parasternal (PS), sternocleidomastoid (SCM) and scalene (SC) muscles in healthy humans during exhaustive exercise. Daily inspiratory muscle strength training was performed for 3 weeks in 10 male subjects (at a pressure threshold load of 60% of maximal inspiratory pressure (MIP) for the first week, 70% of MIP for the second week, and 80% of MIP for the third week). Before and after training, subjects performed an incremental cycle test to exhaustion. Maximal inspiratory pressure and EMG-analysis served as indices of inspiratory muscle fatigue assessment. The before-to-after exercise decreases in MIP and centroid frequency (fc) of the EMG (D, PS, SCM, and SC) power spectrum (P<0.05) were observed in all subjects before the IMT intervention. Such changes were absent after the IMT. The study found that in healthy subjects, IMT results in significant increase in MIP (+18%), a delay of inspiratory muscle fatigue during exhaustive exercise, and a significant improvement in maximal work performance. We conclude that the IMT elicits resistance to the development of inspiratory muscles fatigue during high-intensity exercise.

  3. Effect of volume-oriented versus flow-oriented incentive spirometry on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly.

    PubMed

    Lunardi, Adriana C; Porras, Desiderio C; Barbosa, Renata Cc; Paisani, Denise M; Marques da Silva, Cibele C B; Tanaka, Clarice; Carvalho, Celso R F

    2014-03-01

    Aging causes physiological and functional changes that impair pulmonary function. Incentive spirometry is widely used for lung expansion, but the effects of volume-oriented incentive spirometry (VIS) versus flow-oriented incentive spirometry (FIS) on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly are poorly understood. We compared VIS and FIS in elderly subjects and healthy adult subjects. Sixteen elderly subjects (9 women, mean ± SD age 70.6 ± 3.9 y, mean ± SD body mass index 23.8 ± 2.5 kg/m(2)) and 16 healthy adults (8 women, mean ± age 25.9 ± 4.3 y, mean ± body mass index 23.6 ± 2.4 kg/m(2)) performed quiet breathing, VIS, and FIS in randomized sequence. Chest wall kinematics (via optoelectronic plethysmography) and inspiratory muscle activity (via surface electromyography) were assessed simultaneously. Synchrony between the superior thorax and abdominal motion was calculated (phase angle). In the elderly subjects both types of incentive spirometry increased chest wall volumes similarly, whereas in the healthy adult subjects VIS increased the chest wall volume more than did FIS. FIS and VIS triggered similar lower thoracoabdominal synchrony in the elderly subjects, whereas in the healthy adults FIS induced lower synchrony than did VIS. FIS required more muscle activity in the elderly subjects to create an increase in chest wall volume. Incentive spirometry performance is influenced by age, and the differences between elderly and healthy adults response should be considered in clinical practice.

  4. Effect of inspiratory muscle warm-up on submaximal rowing performance.

    PubMed

    Arend, Mati; Mäestu, Jarek; Kivastik, Jana; Rämson, Raul; Jürimäe, Jaak

    2015-01-01

    Performing inspiratory muscle warm-up might increase exercise performance. The aim of this study was to investigate the impact of inspiratory muscle warm-up to submaximal rowing performance and to find if there is an effect on lactic acid accumulation and breathing parameters. Ten competitive male rowers aged between 19 and 27 years (age, 23.1 ± 3.8 years; height, 188.1 ± 6.3 cm; body mass, 85.6 ± 6.6 kg) were tested 3 times. During the first visit, maximal inspiratory pressure (MIP) assessment and the incremental rowing test were performed to measure maximal oxygen consumption and maximal aerobic power (Pamax). A submaximal intensity (90% Pamax) rowing test was performed twice with the standard rowing warm-up as test 1 and with the standard rowing warm-up and specific inspiratory muscle warm-up as test 2. During the 2 experimental tests, distance, duration, heart rate, breathing frequency, ventilation, peak oxygen consumption, and blood lactate concentration were measured. The only value that showed a significant difference between the test 1 and test 2 was breathing frequency (52.2 ± 6.8 vs. 53.1 ± 6.8, respectively). Heart rate and ventilation showed a tendency to decrease and increase, respectively, after the inspiratory muscle warm-up (p < 0.1). Despite some changes in respiratory parameters, the use of 40% MIP intensity warm-up is not suggested if the mean intensity of the competition is at submaximal level (at approximately 90% maximal oxygen consumption). In conclusion, the warm-up protocol of the respiratory muscles used in this study does not have a significant influence on submaximal endurance performance in highly trained male rowers.

  5. Rapid systematic review shows that using a high-flow nasal cannula is inferior to nasal continuous positive airway pressure as first-line support in preterm neonates.

    PubMed

    Conte, Francesca; Orfeo, Luigi; Gizzi, Camilla; Massenzi, Luca; Fasola, Salvatore

    2018-05-11

    We reviewed using a high-flow nasal cannula (HFNC) as first-line support for preterm neonates with, or at risk of, respiratory distress. This rapid systematic review covered biomedical databases up to June 2017. We included randomised controlled trials (RCTs) published in English. The reference lists of the studies and relevant reviews we included were also screened. We performed the study selection, data extraction, study quality assessment, meta-analysis and quality of evidence assessment following the Grading of Recommendations Assessment, Development and Evaluation system. Pooled results from six RCTs covering 1227 neonates showed moderate-quality evidence that HFNC was associated with a higher rate of failure than nasal continuous positive airway pressure (NCPAP) in preterm neonates of at least 28 weeks of gestation, with a risk ratio of 1.57. Low-quality evidence showed no significant differences between HFNC and NCPAP in the need for intubation and bronchopulmonary dysplasia rate. HFNC yielded a lower rate of nasal injury (risk ratio 0.50). When HFNC failed, intubation was avoided in some neonates by switching them to NCPAP. HFNC had higher failure rates than NCPAP when used as first-line support. Subsequently switching to NCPAP sometimes avoided intubation. Data on the most immature neonates were lacking. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  6. Effects of Ramadan Fasting on Inspiratory Muscle Function.

    PubMed

    Soori, Mohsen; Mohaghegh, Shahram; Hajain, Maryam; Moraadi, Behrooz

    2016-09-01

    Ramadan fasting is a major challenge for exercising Muslims especially in warm seasons. There is some evidence to indicate that Ramadan fasting causes higher subjective ratings of perceived exertion (RPE) in fasting Muslims. The mechanisms of this phenomenon are not known exactly. The role of respiratory muscle strength in this regard has not been studied yet. The aim of this study was investigation of the effects of Ramadan fasting on respiratory muscle strength. In a before-after study, from 35 fasting, apparently healthy, male adults who had fasted from the beginning of Ramadan, maximal inspiratory muscle pressure (MIP) and peak inspiratory flow (PIF) were measured in the last week of Ramadan month in summer. At the time of test, there was not any sleep problem in participants and all of them had good cooperation. Three months later, after exclusion of incompatible persons mainly because of change in their physical activity level, smoking behavior or drug consumption, the measurements were repeated in 12 individuals. Weight, MIP and PIF data had normal distribution (Kolmogorov-Smirnov Test). There was a significant increase in MIP (mean 8.3 cm H 2 O with 95% confidence interval of 2.2 - 14.3) and PIF (mean 0.55 lit/s with 95% confidence interval of 0.02 - 1.07) and weight (mean 3.4 Kg with 95% confidence interval of 2.2 - 4.5) after Ramadan (Paired t test with P < 0.05). When weight difference was used as a covariate in repeated measure ANOVA test, there was no further significant difference between MIP and PIF measurements. Ramadan fasting may cause reduction of respiratory muscle strength through reduction of body weight.

  7. Rhinophototherapy in persistent allergic rhinitis.

    PubMed

    Bella, Zsolt; Kiricsi, Ágnes; Viharosné, Éva Dósa-Rácz; Dallos, Attila; Perényi, Ádám; Kiss, Mária; Koreck, Andrea; Kemény, Lajos; Jóri, József; Rovó, László; Kadocsa, Edit

    2017-03-01

    Previous published results have revealed that Rhinolight ® intranasal phototherapy is safe and effective in intermittent allergic rhinitis. The present objective was to assess whether phototherapy is also safe and effective in persistent allergic rhinitis. Thirty-four patients with persistent allergic rhinitis were randomized into two groups; twenty-five subjects completed the study. The Rhinolight ® group was treated with a combination of UV-B, UV-A, and high-intensity visible light, while the placebo group received low-intensity visible white light intranasal phototherapy on a total of 13 occasions in 6 weeks. The assessment was based on the diary of symptoms, nasal inspiratory peak flow, quantitative smell threshold, mucociliary transport function, and ICAM-1 expression of the epithelial cells. All nasal symptom scores and nasal inspiratory peak flow measurements improved significantly in the Rhinolight ® group relative to the placebo group and this finding persisted after 4 weeks of follow-up. The smell and mucociliary functions did not change significantly in either group. The number of ICAM-1 positive cells decreased non-significantly in the Rhinolight ® group. No severe side-effects were reported during the treatment period. These results suggest that Rhinolight ® treatment is safe and effective in persistent allergic rhinitis.

  8. Control of nasal vasculature and airflow resistance in the dog.

    PubMed Central

    Lung, M A; Phipps, R J; Wang, J C; Widdicombe, J G

    1984-01-01

    Nasal vascular and airflow resistances have been measured in dogs, simultaneously on both sides separately. Vascular resistance was measured either by constant flow perfusion of the terminal branch of the maxillary artery (which supplies, via the sphenopalatine artery, the nasal septum, most of the turbinates and the nasal sinuses) or by measuring blood flow through this artery, maintained by the dog's own blood pressure. Airflow resistance was assessed by inserting balloon-tipped endotracheal catheters into the back of each nasal cavity via the nasopharynx, and measuring transnasal pressure at constant airflow through each side of the nose simultaneously. Preliminary experiments indicated that there was 5-10% collateral anastomosis between the two sides. Close-arterial injection of drugs showed different patterns of response. Adrenaline, phenylephrine, chlorpheniramine and low doses of prostaglandin F2 alpha increased vascular resistance and lowered airway resistance. Salbutamol, methacholine and histamine lowered vascular resistance and increased airway resistance. Dobutamine decreased airway resistance with a small increase in vascular resistance. Prostaglandins E1, E2 and F2 alpha (high dose) decreased both vascular and airway resistances. Substance P, eledoisin-related peptide and vasoactive intestinal polypeptide lowered vascular resistance with little change in airway resistance. The results are interpreted in terms of possible drug actions on precapillary resistance vessels, sinusoids and venules, and arteriovenous anastomoses. It is concluded that nasal airway resistance cannot be correlated with vascular resistance or blood flow, since the latter has a complex and ill-defined relationship with nasal vascular blood volume. PMID:6204040

  9. Control of nasal vasculature and airflow resistance in the dog.

    PubMed

    Lung, M A; Phipps, R J; Wang, J C; Widdicombe, J G

    1984-04-01

    Nasal vascular and airflow resistances have been measured in dogs, simultaneously on both sides separately. Vascular resistance was measured either by constant flow perfusion of the terminal branch of the maxillary artery (which supplies, via the sphenopalatine artery, the nasal septum, most of the turbinates and the nasal sinuses) or by measuring blood flow through this artery, maintained by the dog's own blood pressure. Airflow resistance was assessed by inserting balloon-tipped endotracheal catheters into the back of each nasal cavity via the nasopharynx, and measuring transnasal pressure at constant airflow through each side of the nose simultaneously. Preliminary experiments indicated that there was 5-10% collateral anastomosis between the two sides. Close-arterial injection of drugs showed different patterns of response. Adrenaline, phenylephrine, chlorpheniramine and low doses of prostaglandin F2 alpha increased vascular resistance and lowered airway resistance. Salbutamol, methacholine and histamine lowered vascular resistance and increased airway resistance. Dobutamine decreased airway resistance with a small increase in vascular resistance. Prostaglandins E1, E2 and F2 alpha (high dose) decreased both vascular and airway resistances. Substance P, eledoisin-related peptide and vasoactive intestinal polypeptide lowered vascular resistance with little change in airway resistance. The results are interpreted in terms of possible drug actions on precapillary resistance vessels, sinusoids and venules, and arteriovenous anastomoses. It is concluded that nasal airway resistance cannot be correlated with vascular resistance or blood flow, since the latter has a complex and ill-defined relationship with nasal vascular blood volume.

  10. Visualization of nasal airflow patterns in a patient affected with atrophic rhinitis using particle image velocimetry

    NASA Astrophysics Data System (ADS)

    Garcia, G. J. M.; Mitchell, G.; Bailie, N.; Thornhill, D.; Watterson, J.; Kimbell, J. S.

    2007-10-01

    The relationship between airflow patterns in the nasal cavity and nasal function is poorly understood. This paper reports an experimental study of the interplay between symptoms and airflow patterns in a patient affected with atrophic rhinitis. This pathology is characterized by mucosal dryness, fetor, progressive atrophy of anatomical structures, a spacious nasal cavity, and a paradoxical sensation of nasal congestion. A physical replica of the patient's nasal geometry was made and particle image velocimetry (PIV) was used to visualize and measure the flow field. The nasal replica was based on computed tomography (CT) scans of the patient and was built in three steps: three-dimensional reconstruction of the CT scans; rapid prototyping of a cast; and sacrificial use of the cast to form a model of the nasal passage in clear silicone. Flow patterns were measured by running a water-glycerol mixture through the replica and evaluating the displacement of particles dispersed in the liquid using PIV. The water-glycerol flow rate used corresponded to an air flow rate representative of a human breathing at rest. The trajectory of the flow observed in the left passage of the nose (more affected by atrophic rhinitis) differed markedly from what is considered normal, and was consistent with patterns of epithelial damage observed in cases of the condition. The data are also useful for validation of computational fluid dynamics predictions.

  11. The 'aerobic/resistance/inspiratory muscle training hypothesis in heart failure'.

    PubMed

    Laoutaris, Ioannis D

    2018-01-01

    Evidence from large multicentre exercise intervention trials in heart failure patients, investigating both moderate continuous aerobic training and high intensity interval training, indicates that the 'crème de la crème' exercise programme for this population remains to be found. The 'aerobic/resistance/inspiratory (ARIS) muscle training hypothesis in heart failure' is introduced, suggesting that combined ARIS muscle training may result in maximal exercise pathophysiological and functional benefits in heart failure patients. The hypothesis is based on the decoding of the 'skeletal muscle hypothesis in heart failure' and on revision of experimental evidence to date showing that exercise and functional intolerance in heart failure patients are associated not only with reduced muscle endurance, indication for aerobic training (AT), but also with reduced muscle strength and decreased inspiratory muscle function contributing to weakness, dyspnoea, fatigue and low aerobic capacity, forming the grounds for the addition of both resistance training (RT) and inspiratory muscle training (IMT) to AT. The hypothesis will be tested by comparing all potential exercise combinations, ARIS, AT/RT, AT/IMT, AT, evaluating both functional and cardiac indices in a large sample of heart failure patients of New York Heart Association class II-III and left ventricular ejection fraction ≤35% ad hoc by the multicentre randomized clinical trial, Aerobic Resistance, InSpiratory Training OutcomeS in Heart Failure (ARISTOS-HF trial).

  12. The laser Doppler flowmeter for measuring microcirculation in human nasal mucosa.

    PubMed

    Olsson, P; Bende, M; Ohlin, P

    1985-01-01

    A new technique, based on the laser doppler principle, for measuring nasal mucosal microcirculation in humans, is presented. With this technique the relation between the blood flow and the temperature of the nasal mucosa was evaluated in healthy subjects exposed to peripheral cold stimulus. A decrease in blood flow and in mucosal temperature was found in all subjects when the feet were exposed to cold water for 5 min. The decrease in blood flow occurred almost momentarily and was restored to normal within the 5 min of exposure, while the drop in mucosal temperature was more gradual and persisted for a longer time. The implication of this study is that the laser doppler flowmeter seems to be a useful tool for estimation of changes in nasal mucosal microcirculation.

  13. Velocity Measurements in Nasal Cavities by Means of Stereoscopic Piv - Preliminary Tests

    NASA Astrophysics Data System (ADS)

    Cozzi, Fabio; Felisati, Giovanni; Quadrio, Maurizio

    2017-08-01

    The prediction of detailed flow patterns in human nasal cavities using computational fluid dynamics (CFD) can provide essential information on the potential relationship between patient-specific geometrical characteristics of the nasal anatomy and health problems, and ultimately led to improved surgery. The complex flow structure and the intricate geometry of the nasal cavities make achieving such goals a challenge for CFD specialists. The need for experimental data to validate and improve the numerical simulations is particularly crucial. To this aim an experimental set-up based on Stereo PIV and a silicon phantom of nasal cavities have been designed and realized at Politecnico di Milano. This work describes the main features and challenges of the set-up along with some preliminary results.

  14. Sonographic assessment of changes in diaphragmatic kinetics induced by inspiratory resistive loading.

    PubMed

    Soilemezi, Eleni; Tsagourias, Matthew; Talias, Michael A; Soteriades, Elpidoforos S; Makrakis, Vasilios; Zakynthinos, Epaminondas; Matamis, Dimitrios

    2013-04-01

    Diaphragmatic breathing patterns under resistive loading remain poorly documented. To our knowledge, this is the first study assessing diaphragmatic motion under conditions of inspiratory resistive loading with the use of sonography. We assessed diaphragmatic motion during inspiratory resistive loading in 40 healthy volunteers using M-mode sonography. In phase I of the study, sonography was performed during normal quiet breathing without respiratory loading. In phase II, sonography was performed after application of a nose clip and connection of the subjects to a pneumotachograph through a mouth piece. In phase III, the participants were assessed while subjected to inspiratory resistive loading of 50 cm H(2)O/L/s. Compared with baseline, the application of a mouth piece and nose clip induced a significant increase in diaphragmatic excursion (from 1.7 to 2.3 cm, P < 0.001) and a decrease in respiratory rate (from 13.4 to 12.2, P < 0.01). Inspiratory resistive loading induced a further decrease in respiratory rate (from 12.2 to 8.0, P < 0.01) and a decrease in diaphragmatic velocity contraction (from 1.2 to 0.8 cm/s, P < 0.01), and also an increase in tidal volume (from 795 to 904 mL, P < 0.01); diaphragmatic excursion, however, did not change significantly. Inspiratory resistive loading induced significant changes in diaphragmatic contraction pattern, which mainly consisted of decreased velocity of diaphragmatic displacement with no change in diaphragmatic excursion. Tidal volume, increased significantly; the increase in tidal volume, along with the unchanged diaphragmatic excursion, provides sonographic evidence of increased recruitment of extradiaphragmatic muscles under inspiratory resistive loading. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  15. Are high flow nasal cannulae noisier than bubble CPAP for preterm infants?

    PubMed

    Roberts, C T; Dawson, J A; Alquoka, E; Carew, P J; Donath, S M; Davis, P G; Manley, B J

    2014-07-01

    Noise exposure in the neonatal intensive care unit is believed to be a risk factor for hearing loss in preterm neonates. Continuous positive airway pressure (CPAP) devices exceed recommended noise levels. High flow nasal cannulae (HFNC) are an increasingly popular alternative to CPAP for treating preterm infants, but there are no in vivo studies assessing noise production by HFNC. To study whether HFNC are noisier than bubble CPAP (BCPAP) for preterm infants. An observational study of preterm infants receiving HFNC or BCPAP. Noise levels within the external auditory meatus (EAM) were measured using a microphone probe tube connected to a calibrated digital dosimeter. Noise was measured across a range of frequencies and reported as decibels A-weighted (dBA). A total of 21 HFNC and 13 BCPAP noise measurements were performed in 21 infants. HFNC gas flows were 2-5 L/min, and BCPAP gas flows were 6-10 L/min with set pressures of 5-7 cm of water. There was no evidence of a difference in average noise levels measured at the EAM: mean difference (95% CI) of -1.6 (-4.0 to 0.9) dBA for HFNC compared to BCPAP. At low frequency (500 Hz), HFNC was mean (95% CI) 3.0 (0.3 to 5.7) dBA quieter than BCPAP. Noise increased with increasing BCPAP gas flow (p=0.007), but not with increasing set pressure. There was a trend to noise increasing with increasing HFNC gas flows. At the gas flows studied, HFNC are not noisier than BCPAP for preterm infants.

  16. Optimizing the Respiratory Pump: Harnessing Inspiratory Resistance to Treat Systemic Hypotension

    DTIC Science & Technology

    2011-06-01

    Lurie KG, Vicaut E, Martin D, Gueugniaud PY, Petit JL, Payen D. Evaluation of an impedance threshold device in pa- tients receiving active compression...inspiratory im- pedance threshold device for out-of-hospital cardiac arrest. Cir- culation 2003;108(18):2201-2205. 32. Lindstrom DA, Parquette BA. Use...Lurie KG, Voelckel WG, Zielinski T, McKnite S, Lindstrom P, Peterson C, et al. Improving standard cardiopulmonary resuscitation with an inspiratory

  17. The golden ratio of nasal width to nasal bone length.

    PubMed

    Goynumer, G; Yayla, M; Durukan, B; Wetherilt, L

    2011-01-01

    To calculate the ratio of fetal nasal width over nasal bone length at 14-39 weeks' gestation in Caucasian women. Fetal nasal bone length and nasal width at 14-39 weeks' gestation were measured in 532 normal fetuses. The mean and standard deviations of fetal nasal bone length, nasal width and their ratio to one another were calculated in normal fetuses according to the gestational age to establish normal values. A positive and linear correlation was detected between the nasal bone length and the gestational week, as between the nasal width and the gestational week. No linear growth pattern was found between the gestational week and the ratio of nasal width to nasal bone length, nearly equal to phi, throughout gestation. The ratio of nasal width to nasal bone length, approximately equal to phi, can be calculated at 14-38 weeks' gestation. This might be useful in evaluating fetal abnormalities.

  18. Impact of flow and temperature on patient comfort during respiratory support by high-flow nasal cannula.

    PubMed

    Mauri, Tommaso; Galazzi, Alessandro; Binda, Filippo; Masciopinto, Laura; Corcione, Nadia; Carlesso, Eleonora; Lazzeri, Marta; Spinelli, Elena; Tubiolo, Daniela; Volta, Carlo Alberto; Adamini, Ileana; Pesenti, Antonio; Grasselli, Giacomo

    2018-05-09

    The high-flow nasal cannula (HFNC) delivers up to 60 l/min of humidified air/oxygen blend at a temperature close to that of the human body. In this study, we tested whether higher temperature and flow decrease patient comfort. In more severe patients, instead, we hypothesized that higher flow might be associated with improved comfort. A prospective, randomized, cross-over study was performed on 40 acute hypoxemic respiratory failure (AHRF) patients (PaO 2 /FiO 2  ≤ 300 + pulmonary infiltrates + exclusion of cardiogenic edema) supported by HFNC. The primary outcome was the assessment of patient comfort during HFNC delivery at increasing flow and temperature. Two flows (30 and 60 l/min), each combined with two temperatures (31 and 37 °C), were randomly applied for 20 min (four steps per patient), leaving clinical FiO 2 unchanged. Toward the end of each step, the following were recorded: comfort by Visual Numerical Scale ranging between 1 (extreme discomfort) and 5 (very comfortable), together with respiratory parameters. A subgroup of more severe patients was defined by clinical FiO 2  ≥ 45%. Patient comfort was reported as significantly higher during steps at the lower temperature (31 °C) in comparison to 37 °C, with the HFNC set at both 30 and 60 l/min (p < 0.0001). Higher flow, however, was not associated with poorer comfort. In the subgroup of patients with clinical FiO 2  ≥ 45%, both lower temperature (31 °C) and higher HFNC flow (60 l/min) led to higher comfort (p < 0.01). HFNC temperature seems to significantly impact the comfort of AHRF patients: for equal flow, lower temperature could be more comfortable. Higher flow does not decrease patient comfort; at variance, it improves comfort in the more severely hypoxemic patient.

  19. The incompressibility assumption in computational simulations of nasal airflow.

    PubMed

    Cal, Ismael R; Cercos-Pita, Jose Luis; Duque, Daniel

    2017-06-01

    Most of the computational works on nasal airflow up to date have assumed incompressibility, given the low Mach number of these flows. However, for high temperature gradients, the incompressibility assumption could lead to a loss of accuracy, due to the temperature dependence of air density and viscosity. In this article we aim to shed some light on the influence of this assumption in a model of calm breathing in an Asian nasal cavity, by solving the fluid flow equations in compressible and incompressible formulation for different ambient air temperatures using the OpenFOAM package. At low flow rates and warm climatological conditions, similar results were obtained from both approaches, showing that density variations need not be taken into account to obtain a good prediction of all flow features, at least for usual breathing conditions. This agrees with most of the simulations previously reported, at least as far as the incompressibility assumption is concerned. However, parameters like nasal resistance and wall shear stress distribution differ for air temperatures below [Formula: see text]C approximately. Therefore, density variations should be considered for simulations at such low temperatures.

  20. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount of pressure produced in a patient's airway during maximal inspiration. (b) Classification. Class II...

  1. Fluid mechanics based classification of the respiratory efficiency of several nasal cavities.

    PubMed

    Lintermann, Andreas; Meinke, Matthias; Schröder, Wolfgang

    2013-11-01

    The flow in the human nasal cavity is of great importance to understand rhinologic pathologies like impaired respiration or heating capabilities, a diminished sense of taste and smell, and the presence of dry mucous membranes. To numerically analyze this flow problem a highly efficient and scalable Thermal Lattice-BGK (TLBGK) solver is used, which is very well suited for flows in intricate geometries. The generation of the computational mesh is completely automatic and highly parallelized such that it can be executed efficiently on High Performance Computers (HPCs). An evaluation of the functionality of nasal cavities is based on an analysis of pressure drop, secondary flow structures, wall-shear stress distributions, and temperature variations from the nostrils to the pharynx. The results of the flow fields of three completely different nasal cavities allow their classification into ability groups and support the a priori decision process on surgical interventions. © 2013 Elsevier Ltd. All rights reserved.

  2. Nasal polyps

    MedlinePlus

    ... get rid of nasal polyps. Nasal steroid sprays shrink polyps. They help clear blocked nasal passages and ... is stopped. Corticosteroid pills or liquid may also shrink polyps, and can reduce swelling and nasal congestion. ...

  3. Comparison of Nasal Acceleration and Nasalance across Vowels

    ERIC Educational Resources Information Center

    Thorp, Elias B.; Virnik, Boris T.; Stepp, Cara E.

    2013-01-01

    Purpose: The purpose of this study was to determine the performance of normalized nasal acceleration (NNA) relative to nasalance as estimates of nasalized versus nonnasalized vowel and sentence productions. Method: Participants were 18 healthy speakers of American English. NNA was measured using a custom sensor, and nasalance was measured using…

  4. Virtual surgery for patients with nasal obstruction: Use of computational fluid dynamics (MeComLand®, Digbody® & Noseland®) to document objective flow parameters and optimise surgical results.

    PubMed

    Burgos, Manuel A; Sevilla García, Maria Agustina; Sanmiguel Rojas, Enrique; Del Pino, Carlos; Fernández Velez, Carlos; Piqueras, Francisco; Esteban Ortega, Francisco

    Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. We present a novel CFD software package to improve results following nasal surgery for obstruction. A group of engineers in collaboration with otolaryngologists have developed a very intuitive CFD software package called MeComLand®, which uses the patient's cross-sectional (tomographic) images, thus showing in detail results originated by CFD such as airflow distributions, velocity profiles, pressure, or wall shear stress. NOSELAND® helps medical evaluation with dynamic reports by using a 3D endoscopic view. Using this CFD-based software a patient underwent virtual surgery (septoplasty, turbinoplasty, spreader grafts, lateral crural J-flap and combinations) to choose the best improvement in nasal flow. To present a novel software package to improve nasal surgery results. To apply the software on CT slices from a patient affected by septal deviation. To evaluate several surgical procedures (septoplasty, turbinectomy, spreader-grafts, J-flap and combination among them) to find the best alternative with less morbidity. The combination of all the procedures does not provide the best nasal flow improvement. Septoplasty plus turbinoplasty obtained the best results. Turbinoplasty alone rendered almost similar results to septoplasty in our simulation. CFD provides useful complementary information to cover diagnosis, prognosis, and follow-up of nasal pathologies based on quantitative magnitudes linked to fluid flow. MeComLand®, DigBody® and NoseLand® represent a non-invasive, low-cost alternative for the functional study of patients with nasal obstruction. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  5. The role of the inspiratory muscle weakness in functional capacity in hemodialysis patients

    PubMed Central

    Gomes, Rosalina Tossige; Neves, Camila Danielle Cunha; de Oliveira, Evandro Silveira; Alves, Frederico Lopes; Rodrigues, Vanessa Gomes Brandão; Maciel, Emílio Henrique Barroso

    2017-01-01

    Introduction Inspiratory muscle function may be affected in patients with End-Stage Renal Disease (ESRD), further worsening the functional loss in these individuals. However, the impact of inspiratory muscle weakness (IMW) on the functional capacity (FC) of hemodialysis patients remains unknown. Thus, the present study aimed to evaluate the impact of IMW on FC in ESRD patients undergoing hemodialysis. Materials and methods ESRD patients on hemodialysis treatment for more than six months were evaluated for inspiratory muscle strength and FC. Inspiratory muscle strength was evaluated based on maximal inspiratory pressure (MIP). IMW was defined as MIP values less than 70% of the predicted value. FC was evaluated using the Incremental Shuttle Walk test (ISWT). Patients whose predicted peak oxygen uptake (VO2peak) over the distance walked during the ISWT was less than 16mL/kg/min were considered to have FC impairment. Associations between variables were assessed by linear and logistic regression, with adjustment for age, sex, body mass index (BMI), presence of diabetes and hemoglobin level. Receiver-operating characteristic (ROC) analysis was used to determine different cutoff values of the MIP for normal inspiratory muscle strength and FC. Results Sixty-five ERSD patients (67.7% male), aged 48.2 (44.5–51.9) years were evaluated. MIP was an independent predictor of the distance walked during the ISWT (R2 = 0.44). IMW was an independent predictor of VO2peak < 16mL/kg/min. (OR = 5.7; p = 0.048) in adjusted logistic regression models. ROC curves showed that the MIP cutoff value of 82cmH2O had a sensitivity of 73.5% and specificity of 93.7% in predicting normal inspiratory strength and a sensitivity and specificity of 76.3% and 70.4%, respectively, in predicting VO2peak ≥ 16mL/kg/min. Conclusions IMW is associated with reduced FC in hemodialysis patients. Evaluation of the MIP may be important to functional monitoring in clinical practice and can help in the

  6. The role of the inspiratory muscle weakness in functional capacity in hemodialysis patients.

    PubMed

    Figueiredo, Pedro Henrique Scheidt; Lima, Márcia Maria Oliveira; Costa, Henrique Silveira; Gomes, Rosalina Tossige; Neves, Camila Danielle Cunha; Oliveira, Evandro Silveira de; Alves, Frederico Lopes; Rodrigues, Vanessa Gomes Brandão; Maciel, Emílio Henrique Barroso; Balthazar, Cláudio Heitor

    2017-01-01

    Inspiratory muscle function may be affected in patients with End-Stage Renal Disease (ESRD), further worsening the functional loss in these individuals. However, the impact of inspiratory muscle weakness (IMW) on the functional capacity (FC) of hemodialysis patients remains unknown. Thus, the present study aimed to evaluate the impact of IMW on FC in ESRD patients undergoing hemodialysis. ESRD patients on hemodialysis treatment for more than six months were evaluated for inspiratory muscle strength and FC. Inspiratory muscle strength was evaluated based on maximal inspiratory pressure (MIP). IMW was defined as MIP values less than 70% of the predicted value. FC was evaluated using the Incremental Shuttle Walk test (ISWT). Patients whose predicted peak oxygen uptake (VO2peak) over the distance walked during the ISWT was less than 16mL/kg/min were considered to have FC impairment. Associations between variables were assessed by linear and logistic regression, with adjustment for age, sex, body mass index (BMI), presence of diabetes and hemoglobin level. Receiver-operating characteristic (ROC) analysis was used to determine different cutoff values of the MIP for normal inspiratory muscle strength and FC. Sixty-five ERSD patients (67.7% male), aged 48.2 (44.5-51.9) years were evaluated. MIP was an independent predictor of the distance walked during the ISWT (R2 = 0.44). IMW was an independent predictor of VO2peak < 16mL/kg/min. (OR = 5.7; p = 0.048) in adjusted logistic regression models. ROC curves showed that the MIP cutoff value of 82cmH2O had a sensitivity of 73.5% and specificity of 93.7% in predicting normal inspiratory strength and a sensitivity and specificity of 76.3% and 70.4%, respectively, in predicting VO2peak ≥ 16mL/kg/min. IMW is associated with reduced FC in hemodialysis patients. Evaluation of the MIP may be important to functional monitoring in clinical practice and can help in the stratification of patients eligible to perform exercise testing.

  7. Effects of Inspiratory Muscle Training and Calisthenics-and-Breathing Exercises in COPD With and Without Respiratory Muscle Weakness.

    PubMed

    Basso-Vanelli, Renata P; Di Lorenzo, Valéria A Pires; Labadessa, Ivana G; Regueiro, Eloisa M G; Jamami, Mauricio; Gomes, Evelim L F D; Costa, Dirceu

    2016-01-01

    Patients with COPD may experience respiratory muscle weakness. Two therapeutic approaches to the respiratory muscles are inspiratory muscle training and calisthenics-and-breathing exercises. The aims of the study are to compare the effects of inspiratory muscle training and calisthenics-and-breathing exercises associated with physical training in subjects with COPD as an additional benefit of strength and endurance of the inspiratory muscles, thoracoabdominal mobility, physical exercise capacity, and reduction in dyspnea on exertion. In addition, these gains were compared between subjects with and without respiratory muscle weakness. 25 subjects completed the study: 13 composed the inspiratory muscle training group, and 12 composed the calisthenics-and-breathing exercises group. Subjects were assessed before and after training by spirometry, measurements of respiratory muscle strength and test of inspiratory muscle endurance, thoracoabdominal excursion measurements, and the 6-min walk test. Moreover, scores for the Modified Medical Research Council dyspnea scale were reported. After intervention, there was a significant improvement in both groups of respiratory muscle strength and endurance, thoracoabdominal mobility, and walking distance in the 6-min walk test. Additionally, there was a decrease of dyspnea in the 6-min walk test peak. A difference was found between groups, with higher values of respiratory muscle strength and thoracoabdominal mobility and lower values of dyspnea in the 6-min walk test peak and the Modified Medical Research Council dyspnea scale in the inspiratory muscle training group. In the inspiratory muscle training group, subjects with respiratory muscle weakness had greater gains in inspiratory muscle strength and endurance. Both interventions increased exercise capacity and decreased dyspnea during physical effort. However, inspiratory muscle training was more effective in increasing inspiratory muscle strength and endurance, which could

  8. Nasal deposition of ciclesonide nasal aerosol and mometasone aqueous nasal spray in allergic rhinitis patients.

    PubMed

    Emanuel, Ivor A; Blaiss, Michael S; Meltzer, Eli O; Evans, Philip; Connor, Alyson

    2014-01-01

    Sensory attributes of intranasal corticosteroids, such as rundown to the back of the throat, may influence patient treatment preferences. This study compares the nasal deposition and nasal retention of a radiolabeled solution of ciclesonide nasal aerosol (CIC-hydrofluoroalkane [HFA]) with a radiolabeled suspension of mometasone furoate monohydrate aqueous nasal spray (MFNS) in subjects with either perennial allergic rhinitis (AR) or seasonal AR. In this open-label, single-dose, randomized, crossover scintigraphy study, 14 subjects with symptomatic AR received a single dose of radiolabeled 74-μg CIC-HFA (37 μg/spray, 1 spray/each nostril) via a nasal metered-dose inhaler or a single dose of radiolabeled 200-μg MFNS (50 μg/spray, 2 sprays/each nostril), with a minimum 5-day washout period between treatments. Initial deposition (2 minutes postdose) of radiolabeled CIC-HFA and MFNS in the nasal cavity, nasopharynx, and on nasal wipes, and retention of radioactivity in the nasal cavity and nasal run-out on nasal wipes at 2, 4, 6, 8, and 10 minutes postdose were quantified with scintigraphy. At 2 and 10 minutes postdose, deposition of radiolabeled CIC-HFA was significantly higher in the nasal cavity versus radiolabeled MFNS (99.42% versus 86.50% at 2 minutes, p = 0.0046; and 81.10% versus 54.31% at 10 minutes, p < 0.0001, respectively; p values unadjusted for multiplicity). Deposition of radioactivity on nasal wipes was significantly higher with MFNS versus CIC-HFA at all five time points, and posterior losses of radiolabeled formulation were significantly higher with MFNS at 6, 8, and 10 minutes postdose. In this scintigraphic study, significantly higher nasal deposition and retention of radiolabeled aerosol CIC-HFA were observed versus radiolabeled aqueous MFNS in subjects with AR.

  9. Hydrogen sulphide in human nasal air quantified using thermal desorption and selected ion flow tube mass spectrometry.

    PubMed

    Wondimu, Taddese; Wang, Rui; Ross, Brian

    2014-09-01

    The discovery that hydrogen sulphide (H2S) acts as a gasotransmitter when present at very low concentrations (sub-parts per billion (ppbv)) has resulted in the need to quickly quantify trace amounts of the gas in complex biological samples. Selected ion flow tube mass spectrometry (SIFT-MS) is capable of real-time quantification of H2S but many SIFT-MS instruments lack sufficient sensitivity for this application. In this study we investigate the utility of combining thermal desorption with SIFT-MS for quantifying H2S in the 0.1-1 ppbv concentration range. Human orally or nasally derived breath, and background ambient air, were collected in sampling bags and dried by passing through CaCl2 and H2S pre-concentrated using a sorbent trap optimised for the capture of this gas. The absorbed H2S was then thermally desorbed and quantified by SIFT-MS. H2S concentrations in ambient air, nasal breath and oral breath collected from 10 healthy volunteers were 0.12  ±  0.02 (mean ± SD), 0.40  ±  0.11 and 3.1  ±  2.5 ppbv respectively, and in the oral cavity H2S, quantified by SIFT-MS without pre-concentration, was present at 13.5  ±  8.6 ppbv. The oral cavity H2S correlates well with oral breath H2S but not with nasal breath H2S, suggesting that oral breath H2S derives mainly from the oral cavity but nasal breath is likely pulmonary in origin. The successful quantification of such low concentrations of H2S in nasal air using a rapid analytical procedure paves the way for the straightforward analysis of H2S in breath and may assist in elucidating the role that H2S plays in biological systems.

  10. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system.

    PubMed

    Hentschel, Roland; Semar, Nicole; Guttmann, Josef

    2012-09-01

    To study appropriateness of respiratory system compliance calculation using an inflation hold and compare it with ventilator readouts of pressure and tidal volume as well as with measurement of compliance of the respiratory system with the single-breath-single-occlusion technique gained with a standard lung function measurement. Prospective clinical trial. Level III neonatal unit of a university hospital. Sixty-seven newborns, born prematurely or at term, ventilated for a variety of pathologic conditions. A standardized sigh maneuver with a predefined peak inspiratory pressure of 30 cm H2O, termed inspiratory capacity at inflation hold, was applied. Using tidal volume, exhaled from inspiratory pause down to ambient pressure, as displayed by the ventilator, and predefined peak inspiratory pressure, compliance at inspiratory capacity at inflation hold conditions could be calculated as well as ratio of tidal volume and ventilator pressure using tidal volume and differential pressure at baseline ventilator settings: peak inspiratory pressure minus positive end-expiratory pressure. For the whole cohort, the equation for the regression between tidal volume at inspiratory capacity at inflation hold and compliance of the respiratory system was: compliance of the respiratory system = 0.052 * tidal volume at inspiratory capacity at inflation hold - 0.113, and compliance at inspiratory capacity at inflation hold conditions was closely related to the standard lung function measurement method of compliance of the respiratory system (R = 0.958). In contrast, ratio of tidal volume and ventilator pressure per kilogram calculated from the ventilator readouts and displayed against compliance of the respiratory system per kilogram yielded a broad scatter throughout the whole range of compliance; both were only weakly correlated (R = 0.309) and also the regression line was significantly different from the line of identity (p < .05). Peak inspiratory pressure at study entry did not

  11. Activation of respiratory muscles during respiratory muscle training.

    PubMed

    Walterspacher, Stephan; Pietsch, Fabian; Walker, David Johannes; Röcker, Kai; Kabitz, Hans-Joachim

    2018-01-01

    It is unknown which respiratory muscles are mainly activated by respiratory muscle training. This study evaluated Inspiratory Pressure Threshold Loading (IPTL), Inspiratory Flow Resistive Loading (IFRL) and Voluntary Isocapnic Hyperpnea (VIH) with regard to electromyographic (EMG) activation of the sternocleidomastoid muscle (SCM), parasternal muscles (PARA) and the diaphragm (DIA) in randomized order. Surface EMG were analyzed at the end of each training session and normalized using the peak EMG recorded during maximum inspiratory maneuvers (Sniff nasal pressure: SnPna, maximal inspiratory mouth occlusion pressure: PImax). 41 healthy participants were included. Maximal activation was achieved for SCM by SnPna; the PImax activated predominantly PARA and DIA. Activations of SCM and PARA were higher in IPTL and VIH than for IFRL (p<0.05). DIA was higher applying IPTL compared to IFRL or VIH (p<0.05). IPTL, IFRL and VIH differ in activation of inspiratory respiratory muscles. Whereas all methods mainly stimulate accessory respiratory muscles, diaphragm activation was predominant in IPTL. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Objective Measure of Nasal Air Emission Using Nasal Accelerometry

    ERIC Educational Resources Information Center

    Cler, Meredith J.; Lien, Yu-An, S.; Braden, Maia N.; Mittleman, Talia; Downing, Kerri; Stepp, Cara, E.

    2016-01-01

    Purpose: This article describes the development and initial validation of an objective measure of nasal air emission (NAE) using nasal accelerometry. Method: Nasal acceleration and nasal airflow signals were simultaneously recorded while an expert speech language pathologist modeled NAEs at a variety of severity levels. In addition, microphone and…

  13. Systematic Review of Inspiratory Muscle Training After Cerebrovascular Accident.

    PubMed

    Martín-Valero, Rocío; De La Casa Almeida, Maria; Casuso-Holgado, Maria Jesus; Heredia-Madrazo, Alfonso

    2015-11-01

    This systematic review examines levels of evidence and recommendation grades of various therapeutic interventions of inspiratory muscle training in people who have had a stroke. Benefits from different levels of force and resistance in respiratory muscles are shown in this population. This review was conducted following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) directives and was completed in November 2014. The search limits were studies published in English between 2004 and 2014. Relevant studies were searched for in MEDLINE, PEDro, OAIster, Scopus, PsycINFO, Web of Knowledge, CINAHL, SPORTDiscus, DOAJ, Cochrane, Embase, Academic Search Complete, Fuente Académica, and MedicLatina. Initially, 20 articles were identified. After analyzing all primary documents, 14 studies were excluded. Only 6 studies were relevant to this review. Three different types of interventions were found (maximum inspiratory training, controlled training, and nonintervention) in 3 different groups. One specific study compared 3 inspiratory muscle training groups with a group of breathing exercises (diaphragmatic exercises with pursed lips) and a control group. Future long-term studies with larger sample sizes are needed. It is necessary to apply respiratory muscle training as a service of the national health system and to consider its inclusion in the conventional neurological program. Copyright © 2015 by Daedalus Enterprises.

  14. The effect of inspiratory and expiratory respiratory muscle training in rowers.

    PubMed

    Forbes, S; Game, A; Syrotuik, D; Jones, R; Bell, G J

    2011-10-01

    This study examined inspiratory and expiratory resistive loading combined with strength and endurance training on pulmonary function and rowing performance. Twenty-one male (n = 9) and female (n = 12) rowers were matched on 2000 m simulated rowing race time and gender and randomly assigned to two groups. The experimental group trained respiratory muscles using a device that provided both an inspiratory and expiratory resistance while the control group used a SHAM device. Respiratory muscle training (RMT) or SHAM was performed 6 d/wk concurrent with strength (3 d/wk) and endurance (3 d/wk) training on alternate days for 10 weeks. Respiratory muscle training (RMT) enhanced maximum inspiratory (PI(max)) and expiratory (PE(max)) strength at rest and during recovery from exercise (P < 0.05). Both groups showed improvements in peak VO2, strength, and 2000 m performance time (P < 0.05). It was concluded that RMT is effective for improving respiratory strength but did not facilitate greater improvements to simulated 2000 m rowing performance.

  15. Assessment of nasal spray deposition pattern in a silicone human nose model using a color-based method.

    PubMed

    Kundoor, Vipra; Dalby, Richard N

    2010-01-01

    To develop a simple and inexpensive method to visualize and quantify droplet deposition patterns. Deposition pattern was determined by uniformly coating the nose model with Sar-Gel (a paste that changes from white to purple on contact with water) and subsequently discharging sprays into the nose model. The color change was captured using a digital camera and analyzed using Adobe Photoshop. Several tests were conducted to validate the method. Deposition patterns of different nasal sprays (Ayr, Afrin, and Zicam) and different nasal drug delivery devices (Afrin nasal spray and PARI Sinustar nasal nebulizer) were compared. We also used the method to evaluate the effect of inhaled flow rate on nasal spray deposition. There was a significant difference in the deposition area for Ayr, Afrin, and Zicam. The deposition areas of Afrin nasal spray and PARI Sinustar nasal nebulizer (2 min and 5 min) were significantly different. Inhaled flow rate did not have a significant effect on the deposition pattern. Lower viscosity formulations (Ayr, Afrin) provided greater coverage than the higher viscosity formulation (Zicam). The nebulizer covered a greater surface area than the spray pump we evaluated. Aerosol deposition in the nose model was not affected by air flow conditions.

  16. Maximal inspiratory pressure is influenced by intensity of the warm-up protocol.

    PubMed

    Arend, Mati; Kivastik, Jana; Mäestu, Jarek

    2016-08-01

    The aim of the study was to compare the effect of inspiratory muscle warm-up protocols with different intensities and breathing repetitions on maximal inspiratory pressure (MIP). Ten healthy and recreationally active men (183.3±5.5cm, 83.7±7.8kg, 26.4±4.1years) completed four different inspiratory muscle (IM) warm-up protocols (2×30 inspirations at 40% MIP, 2×12 inspirations at 60% MIP, 2×6 inspirations at 80% MIP, 2×30 inspirations at 15% MIP) on separate, randomly assigned visits. Pre-post values of MIP using MicroRPM (Micro Medical, Kent, UK) showed a significant increase in the mean values after the IM warm-up (POWERbreathe(®) K1, Warwickshire, UK) with 40% MIP and 60% MIP warm-up protocols, when MIP increased by 7cm H2O (95% CI: 0.10…13.89) (p=0.047) and by 6.4cm H2O (95% CI: 2.98…13.83) (p=0.027), respectively. In conclusion, a higher intensity inspiratory muscle warm-up protocol (2×12 breaths at 60% of MIP) can increase IM strength. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. High-Flow, Heated, Humidified Air Via Nasal Cannula Treats CPAP-Intolerant Children With Obstructive Sleep Apnea

    PubMed Central

    Hawkins, Stephen; Huston, Stephanie; Campbell, Kristen; Halbower, Ann

    2017-01-01

    Study Objectives: Continuous positive airway pressure (CPAP) is effective but challenging for children with obstructive sleep apnea (OSA). High-flow air via open nasal cannula (HFNC) as treatment in children remains controversial. We report the efficacy of HFNC in children with OSA and CPAP intolerance, a titration protocol, and a discussion of potential mechanisms. Methods: Patients aged 1 to 18 years with OSA (defined by obstructive apnea-hypopnea index [OAHI] greater than 1 event/h) and CPAP intolerance were enrolled. Routine polysomnography data obtained during 1 night wearing HFNC was compared with diagnostic data by Wilcoxon rank-sum test. Results: Ten school-age subjects (representing all patients attempting HFNC at our institution to date) with varied medical conditions, moderate to severe OSA, and CPAP intolerance wore HFNC from 10 to 50 L/min of room air with oxygen supplementation if needed (room air alone for 6 of the 10). HFNC reduced median OAHI from 11.1 events/h (interquartile range 8.7–18.8 events/h) to 2.1 events/h (1.7–2.2 events/h; P = .002); increased oxyhemoglobin saturation (SpO2) mean from 91.3% (89.6% to 93.5%) to 94.9% (92.4% to 96.0%; P < .002); increased SpO2 nadir from 76.0% (67.3% to 82.3%) to 79.5% (77.2% to 86.0%; P = .032); decreased SpO2 desaturation index from 19.2 events/h (12.7–25.8 events/h) to 6.4 events/h (4.7–10.7 events/h; P = .013); and reduced heart rate from 88 bpm (86–91 bpm) to 74 bpm (67–81 bpm; P = .004). Stratified analysis of the 6 subjects with only room air via HFNC, the OAHI, obstructive hypopnea index, and mean SpO2 still demonstrated improvements (P = .031). Conclusions: High-flow nasal cannula reduces respiratory events, improves oxygenation, reduces heart rate, and may be effective for CPAP intolerant children with moderate to severe OSA. Our data suggest HFNC warrants further study and consideration by payers as OSA therapy. Citation: Hawkins S, Huston S, Campbell K, Halbower A. High-flow

  18. A proprietary blend of quail egg for the attenuation of nasal provocation with a standardized allergenic challenge: a randomized, double-blind, placebo-controlled study

    PubMed Central

    Benichou, Annie-Claude; Armanet, Marion; Bussière, Anthony; Chevreau, Nathalie; Cardot, Jean-Michel; Tétard, Jan

    2014-01-01

    Occasional rhinitis symptoms caused by exposure to pollution or allergens is a growing concern. Based first on empirical observation of a lesser occurrence of allergies in quail farmers and then scientific works on ovomucoids properties, we developed a dietary supplement for the relief of such occasional rhinitis symptoms. The objective of the study was to determine whether one acute oral dose of the study product attenuates nasal provocation and other allergy-related symptoms after exposure to a standardized allergenic challenge as compared to placebo. Healthy subjects were recruited to participate in a randomized, double-blind, two-arm crossover, placebo-controlled, clinical trial. One acute dose of either the active study product (proprietary blend of quail egg) or placebo was given concomitantly to the standardized allergenic challenge. The primary endpoint was peak nasal inspiratory flow (PNIF) measurement and the secondary endpoints were subjects' perceived feelings of well-being based on Visual Analog Scale (VAS) scores for allergy-related symptoms, as well as immunoglobulin E count. Forty-three healthy subjects were enrolled and evaluable in a per protocol analysis. A gradual increase in PNIF from nadir up to Time 120 reflected the normal, gradual recovery from nasal obstruction induced by allergenic challenge for both the active and the placebo groups. At all postchallenge time points, the active group had higher PNIF values compared to the placebo group, indicating that the active product was associated with fewer symptoms and reduced intensity of these symptoms. The active product resulted also in statistically significant improvements of most of the subjects' perceived feelings of well-being based on VAS scores. No adverse events occurred during the study. In conclusion, the dietary supplement consisting of proprietary blend made of quail eggs provides fast and efficient relief of allergic rhinitis symptoms caused by the most common outdoor and indoor

  19. [Effectiveness of nasal positive pressure ventilation in the management of acute refractory left ventricular insufficiency].

    PubMed

    Chesi, G; Pinelli, G; Galimberti, D; Navazio, A; Montanari, P

    1994-04-01

    Ehen refractory to optimal medical treatment cardiogenic pulmonary edema requires mechanical ventilation as a last therapeutic resource. In recent years an increasing number of authors reported their experience in the management of acute or subacute respiratory failure with non-invasive mechanical ventilation by nasal mask. Encouraged by the first promising results reported in literature we experimented this new therapeutic tool in a first group of seven elderly patients (mean age: 76.57--range: 65-89); they all had been admitted for severe cardiogenic pulmonary edema unresponsive to maximal doses of the conventional drugs available for treating acute decompensated heart failure. The enrolled patients were treated with intermittent ventilation administered by nasal mask at selected values of inspiratory positive airway pressure (IPAP) that were comprised between 10 and 20 cm H2O. At the same time an expiratory positive airway pressure (EPAP) at values comprised between 3 and 8 cm H2O was applied. Ventilation was continued for variable periods of 3-24 hours until acceptable values of PaO2 and PaCO2 were obtained. The ventilation modality was spontaneous, spontaneous-time or timed depending on the patients' level of consciousness at starting time. A good short-term outcome was achieved in all the patients regardless of the ventilation modality applied. The main blood gas alteration was severe hypercapnia with acidosis in three patients, while the other four presented critical hypoxemia unresponsive to simple oxygen supply even if delivered by high-flow Venturi mask. Four of our seven patients were discharged from hospital in satisfactory haemodynamic conditions; the remaining three died during hospitalization from refractory heart failure. In this our preliminary experience the therapeutic approach with nasal positive pressure ventilation (NPPV) and EPAP proved to be very effective to improve the signs and symptoms of acute refractory cardiogenic pulmonary edema as

  20. Humidified high flow nasal cannulae: current practice in Australasian nurseries, a survey.

    PubMed

    Hough, Judith L; Shearman, Andrew D; Jardine, Luke A; Davies, Mark W

    2012-02-01

    Humidified High Flow Nasal Cannula (HHFNC) has been increasingly adopted as a new means of respiratory support throughout the world. However, evidence to support its safety and efficacy is limited. The aim of the present survey was to determine current practices regarding the usage of HHFNC by neonatologists in Australia and New Zealand. Surveys were sent to all 167 neonatologists identified by the list of centres in the Australia and New Zealand Neonatal Network. A total of 157 surveys were sent to valid email addresses: 111 (71%) responded of which 105 (67%) had completed the questionnaire. HHFNC is used in 17 (63%) of neonatal intensive care units in Australia and New Zealand. It is most commonly used to reduce nasal trauma (91%) and provide continuous positive airways pressure (62%). The main perceived benefits of HHFNC were the easier application and care of the infant (86%), and improved tolerance by the baby (84%). Rain out leading to fluid instillation into the upper airway (59%) was the most common problem. This survey has provided a snapshot of the practice of HHFNC usage in Australia and New Zealand in 2010 and has revealed that HHFNC use is widespread and that clinical practices are diverse. The majority of neonatologists acknowledge that there is limited evidence to support its efficacy and safety, and would be happy to participate in clinical trials to address how best to deliver HHFNC. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  1. Learning to breathe? Feedforward regulation of the inspiratory motor drive.

    PubMed

    Zaman, Jonas; Van den Bergh, Omer; Fannes, Stien; Van Diest, Ilse

    2014-09-15

    Claims have been made that breathing is in part controlled by feedforward regulation. In a classical conditioning paradigm, we investigated anticipatory increases in the inspiratory motor drive as measured by inspiratory occlusion pressure (P100). In an acquisition phase, an experimental group (N=13) received a low-intensity resistive load (5 cmH2O/l/s) for three consecutive inspirations as Conditioned Stimulus (CS), preceding a load of a stronger intensity (20 cmH2O/l/s) for three subsequent inspirations as unconditioned stimulus (US). The control group (N=11) received the low-intensity load for six consecutive inspirations. In a post-acquisition phase both groups received the low-intensity load for six consecutive inspirations. Responses to the CS-load only differed between groups during the first acquisition trials and a strong increase in P100 during the US-loads was observed, which habituated across the experiment. Our results suggest that the disruption caused by adding low to moderate resistive loads to three consecutive inspirations results in a short-lasting anticipatory increase in inspiratory motor drive. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Effects of inspiratory muscle training on respiratory muscle electromyography and dyspnea during exercise in healthy men.

    PubMed

    Ramsook, Andrew H; Molgat-Seon, Yannick; Schaeffer, Michele R; Wilkie, Sabrina S; Camp, Pat G; Reid, W Darlene; Romer, Lee M; Guenette, Jordan A

    2017-05-01

    Inspiratory muscle training (IMT) has consistently been shown to reduce exertional dyspnea in health and disease; however, the physiological mechanisms remain poorly understood. A growing body of literature suggests that dyspnea intensity can be explained largely by an awareness of increased neural respiratory drive, as measured indirectly using diaphragmatic electromyography (EMGdi). Accordingly, we sought to determine whether improvements in dyspnea following IMT can be explained by decreases in inspiratory muscle electromyography (EMG) activity. Twenty-five young, healthy, recreationally active men completed a detailed familiarization visit followed by two maximal incremental cycle exercise tests separated by 5 wk of randomly assigned pressure threshold IMT or sham control (SC) training. The IMT group ( n = 12) performed 30 inspiratory efforts twice daily against a 30-repetition maximum intensity. The SC group ( n = 13) performed a daily bout of 60 inspiratory efforts against 10% maximal inspiratory pressure (MIP), with no weekly adjustments. Dyspnea intensity was measured throughout exercise using the modified 0-10 Borg scale. Sternocleidomastoid and scalene EMG was measured using surface electrodes, whereas EMGdi was measured using a multipair esophageal electrode catheter. IMT significantly improved MIP (pre: -138 ± 45 vs. post: -160 ± 43 cmH 2 O, P < 0.01), whereas the SC intervention did not. Dyspnea was significantly reduced at the highest equivalent work rate (pre: 7.6 ± 2.5 vs. post: 6.8 ± 2.9 Borg units, P < 0.05), but not in the SC group, with no between-group interaction effects. There were no significant differences in respiratory muscle EMG during exercise in either group. Improvements in dyspnea intensity ratings following IMT in healthy humans cannot be explained by changes in the electrical activity of the inspiratory muscles. NEW & NOTEWORTHY Exertional dyspnea intensity is thought to reflect an increased awareness of neural respiratory

  3. Effects of inspiratory muscle training on respiratory muscle electromyography and dyspnea during exercise in healthy men

    PubMed Central

    Molgat-Seon, Yannick; Schaeffer, Michele R.; Wilkie, Sabrina S.; Camp, Pat G.; Reid, W. Darlene; Romer, Lee M.

    2017-01-01

    Inspiratory muscle training (IMT) has consistently been shown to reduce exertional dyspnea in health and disease; however, the physiological mechanisms remain poorly understood. A growing body of literature suggests that dyspnea intensity can be explained largely by an awareness of increased neural respiratory drive, as measured indirectly using diaphragmatic electromyography (EMGdi). Accordingly, we sought to determine whether improvements in dyspnea following IMT can be explained by decreases in inspiratory muscle electromyography (EMG) activity. Twenty-five young, healthy, recreationally active men completed a detailed familiarization visit followed by two maximal incremental cycle exercise tests separated by 5 wk of randomly assigned pressure threshold IMT or sham control (SC) training. The IMT group (n = 12) performed 30 inspiratory efforts twice daily against a 30-repetition maximum intensity. The SC group (n = 13) performed a daily bout of 60 inspiratory efforts against 10% maximal inspiratory pressure (MIP), with no weekly adjustments. Dyspnea intensity was measured throughout exercise using the modified 0–10 Borg scale. Sternocleidomastoid and scalene EMG was measured using surface electrodes, whereas EMGdi was measured using a multipair esophageal electrode catheter. IMT significantly improved MIP (pre: −138 ± 45 vs. post: −160 ± 43 cmH2O, P < 0.01), whereas the SC intervention did not. Dyspnea was significantly reduced at the highest equivalent work rate (pre: 7.6 ± 2.5 vs. post: 6.8 ± 2.9 Borg units, P < 0.05), but not in the SC group, with no between-group interaction effects. There were no significant differences in respiratory muscle EMG during exercise in either group. Improvements in dyspnea intensity ratings following IMT in healthy humans cannot be explained by changes in the electrical activity of the inspiratory muscles. NEW & NOTEWORTHY Exertional dyspnea intensity is thought to reflect an increased awareness of neural respiratory

  4. Similarity and Enhancement: Nasality from Moroccan Arabic Pharyngeals and Nasals

    ERIC Educational Resources Information Center

    Zellou, Georgia Eve

    2012-01-01

    Experimental studies of the articulation, acoustics, and perception of nasal and pharyngeal consonants and adjacent vowels were conducted to investigate nasality in Moroccan Arabic (MA). The status of nasality in MA is described as coarticulatorily complex, where two phoneme types (pharyngeal segments and nasal segments) yield similar…

  5. Early experience with high-flow nasal oxygen therapy (HFNOT) in pediatric endoscopic airway surgery.

    PubMed

    Riva, Thomas; Theiler, Lorenz; Jaquet, Yves; Giger, Roland; Nisa, Lluís

    2018-05-01

    Reporting our institutional experience with high-flow nasal oxygen therapy (HFNOT), a recently-introduced technique, for endoscopic airway approaches. Prospective collection of data of children (<16 years) undergoing endoscopic between January 2016 and August 2017 at a tertiary referral university hospital. HFNOT was used in 6 children who underwent 14 procedures for different forms and causes of upper airway obstruction of various origins. No intraoperative complications; related to oxygenation were observed, and the surgical procedures could be carried out as; initially planned. We found that HFNOT is an effective and safe technique with a variety of potential applications in the field of endoscopic pediatric airway surgery. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    PubMed

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  7. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery

    PubMed Central

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-01-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function. PMID:23460599

  8. The influence of inspiratory effort and emphysema on pulmonary nodule volumetry reproducibility.

    PubMed

    Moser, J B; Mak, S M; McNulty, W H; Padley, S; Nair, A; Shah, P L; Devaraj, A

    2017-11-01

    To evaluate the impact of inspiratory effort and emphysema on reproducibility of pulmonary nodule volumetry. Eighty-eight nodules in 24 patients with emphysema were studied retrospectively. All patients had undergone volumetric inspiratory and end-expiratory thoracic computed tomography (CT) for consideration of bronchoscopic lung volume reduction. Inspiratory and expiratory nodule volumes were measured using commercially available software. Local emphysema extent was established by analysing a segmentation area extended circumferentially around each nodule (quantified as percent of lung with density of -950 HU or less). Lung volumes were established using the same software. Differences in inspiratory and expiratory nodule volumes were illustrated using the Bland-Altman test. The influences of percentage reduction in lung volume at expiration, local emphysema extent, and nodule size on nodule volume variability were tested with multiple linear regression. The majority of nodules (59/88 [67%]) showed an increased volume at expiration. Mean difference in nodule volume between expiration and inspiration was +7.5% (95% confidence interval: -24.1, 39.1%). No relationships were demonstrated between nodule volume variability and emphysema extent, degree of expiration, or nodule size. Expiration causes a modest increase in volumetry-derived nodule volumes; however, the effect is unpredictable. Local emphysema extent had no significant effect on volume variability in the present cohort. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Saline nasal washes

    MedlinePlus

    ... nasal wash helps flush pollen, dust, and other debris from your nasal passages. It also helps remove excess mucus (snot) and adds moisture. Your nasal passages are open spaces behind your nose. Air passes through your nasal ...

  10. Impaired Air Conditioning within the Nasal Cavity in Flat-Faced Homo

    PubMed Central

    Nishimura, Takeshi; Mori, Futoshi; Hanida, Sho; Kumahata, Kiyoshi; Ishikawa, Shigeru; Samarat, Kaouthar; Miyabe-Nishiwaki, Takako; Hayashi, Misato; Tomonaga, Masaki; Suzuki, Juri; Matsuzawa, Tetsuro; Matsuzawa, Teruo

    2016-01-01

    We are flat-faced hominins with an external nose that protrudes from the face. This feature was derived in the genus Homo, along with facial flattening and reorientation to form a high nasal cavity. The nasal passage conditions the inhaled air in terms of temperature and humidity to match the conditions required in the lung, and its anatomical variation is believed to be evolutionarily sensitive to the ambient atmospheric conditions of a given habitat. In this study, we used computational fluid dynamics (CFD) with three-dimensional topology models of the nasal passage under the same simulation conditions, to investigate air-conditioning performance in humans, chimpanzees, and macaques. The CFD simulation showed a horizontal straight flow of inhaled air in chimpanzees and macaques, contrasting with the upward and curved flow in humans. The inhaled air is conditioned poorly in humans compared with nonhuman primates. Virtual modifications to the human external nose topology, in which the nasal vestibule and valve are modified to resemble those of chimpanzees, change the airflow to be horizontal, but have little influence on the air-conditioning performance in humans. These findings suggest that morphological variation of the nasal passage topology was only weakly sensitive to the ambient atmosphere conditions; rather, the high nasal cavity in humans was formed simply by evolutionary facial reorganization in the divergence of Homo from the other hominin lineages, impairing the air-conditioning performance. Even though the inhaled air is not adjusted well within the nasal cavity in humans, it can be fully conditioned subsequently in the pharyngeal cavity, which is lengthened in the flat-faced Homo. Thus, the air-conditioning faculty in the nasal passages was probably impaired in early Homo members, although they have survived successfully under the fluctuating climate of the Plio-Pleistocene, and then they moved “Out of Africa” to explore the more severe climates of

  11. Impaired Air Conditioning within the Nasal Cavity in Flat-Faced Homo.

    PubMed

    Nishimura, Takeshi; Mori, Futoshi; Hanida, Sho; Kumahata, Kiyoshi; Ishikawa, Shigeru; Samarat, Kaouthar; Miyabe-Nishiwaki, Takako; Hayashi, Misato; Tomonaga, Masaki; Suzuki, Juri; Matsuzawa, Tetsuro; Matsuzawa, Teruo

    2016-03-01

    We are flat-faced hominins with an external nose that protrudes from the face. This feature was derived in the genus Homo, along with facial flattening and reorientation to form a high nasal cavity. The nasal passage conditions the inhaled air in terms of temperature and humidity to match the conditions required in the lung, and its anatomical variation is believed to be evolutionarily sensitive to the ambient atmospheric conditions of a given habitat. In this study, we used computational fluid dynamics (CFD) with three-dimensional topology models of the nasal passage under the same simulation conditions, to investigate air-conditioning performance in humans, chimpanzees, and macaques. The CFD simulation showed a horizontal straight flow of inhaled air in chimpanzees and macaques, contrasting with the upward and curved flow in humans. The inhaled air is conditioned poorly in humans compared with nonhuman primates. Virtual modifications to the human external nose topology, in which the nasal vestibule and valve are modified to resemble those of chimpanzees, change the airflow to be horizontal, but have little influence on the air-conditioning performance in humans. These findings suggest that morphological variation of the nasal passage topology was only weakly sensitive to the ambient atmosphere conditions; rather, the high nasal cavity in humans was formed simply by evolutionary facial reorganization in the divergence of Homo from the other hominin lineages, impairing the air-conditioning performance. Even though the inhaled air is not adjusted well within the nasal cavity in humans, it can be fully conditioned subsequently in the pharyngeal cavity, which is lengthened in the flat-faced Homo. Thus, the air-conditioning faculty in the nasal passages was probably impaired in early Homo members, although they have survived successfully under the fluctuating climate of the Plio-Pleistocene, and then they moved "Out of Africa" to explore the more severe climates of

  12. Airflow, gas deposition, and lesion distribution in the nasal passages.

    PubMed Central

    Morgan, K T; Monticello, T M

    1990-01-01

    The nasal passages of laboratory animals and man are complex, and lesions induced in the delicate nasal lining by inhaled air pollutants vary considerably in location and nature. The distribution of nasal lesions is generally a consequence of regional deposition of the inhaled material, local tissue susceptibility, or a combination of these factors. Nasal uptake and regional deposition are are influenced by numerous factors including the physical and chemical properties of the inhaled material, such as water solubility and reactivity; airborne concentration and length of exposure; the presence of other air contaminants such as particulate matter; nasal metabolism, and blood and mucus flow. For certain highly water-soluble or reactive gases, nasal airflow patterns play a major role in determining lesion distribution. Studies of nasal airflow in rats and monkeys, using casting and molding techniques combined with a water-dye model, indicate that nasal airflow patterns are responsible for characteristic differences in the distribution of nasal lesions induced by formaldehyde in these species. Local tissue susceptibility is also a complex issue that may be a consequence of many factors, including physiologic and metabolic characteristics of the diverse cell populations that comprise each of the major epithelial types lining the airways. Identification of the principal factors that influence the distribution and nature of nasal lesions is important when attempting the difficult process of determining potential human risks using data derived from laboratory animals. Toxicologic pathologists can contribute to this process by carefully identifying the site and nature of nasal lesions induced by inhaled materials. Images FIGURE 4. FIGURE 6. FIGURE 7. PMID:2200663

  13. Patient specific CFD models of nasal airflow: overview of methods and challenges.

    PubMed

    Kim, Sung Kyun; Na, Yang; Kim, Jee-In; Chung, Seung-Kyu

    2013-01-18

    Respiratory physiology and pathology are strongly dependent on the airflow inside the nasal cavity. However, the nasal anatomy, which is characterized by complex airway channels and significant individual differences, is difficult to analyze. Thus, commonly adopted diagnostic tools have yielded limited success. Nevertheless, with the rapid advances in computer resources, there have been more elaborate attempts to correlate airflow characteristics in human nasal airways with the symptoms and functions of the nose by computational fluid dynamics study. Furthermore, the computed nasal geometry can be virtually modified to reflect predicted results of the proposed surgical technique. In this article, several computational fluid mechanics (CFD) issues on patient-specific three dimensional (3D) modeling of nasal cavity and clinical applications were reviewed in relation to the cases of deviated nasal septum (decision for surgery), turbinectomy, and maxillary sinus ventilation (simulated- and post-surgery). Clinical relevance of fluid mechanical parameters, such as nasal resistance, flow allocation, wall shear stress, heat/humidity/NO gas distributions, to the symptoms and surgical outcome were discussed. Absolute values of such parameters reported by many research groups were different each other due to individual difference of nasal anatomy, the methodology for 3D modeling and numerical grid, laminar/turbulent flow model in CFD code. But, the correlation of these parameters to symptoms and surgery outcome seems to be obvious in each research group with subject-specific models and its variations (virtual- and post-surgery models). For the more reliable, patient-specific, and objective tools for diagnosis and outcomes of nasal surgery by using CFD, the future challenges will be the standardizations on the methodology for creating 3D airway models and the CFD procedures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study.

    PubMed

    Roopa Manjunatha, G; Rajanna, K; Mahapatra, D Roy; Nayak, M M; Krishnaswamy, Uma Maheswari; Srinivasa, R

    2013-12-01

    Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 ± 4.1) and the RIP (19.57 ± 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.

  15. Bench experiments comparing simulated inspiratory effort when breathing helium-oxygen mixtures to that during positive pressure support with air

    PubMed Central

    2012-01-01

    Background Inhalation of helium-oxygen (He/O2) mixtures has been explored as a means to lower the work of breathing of patients with obstructive lung disease. Non-invasive ventilation (NIV) with positive pressure support is also used for this purpose. The bench experiments presented herein were conducted in order to compare simulated patient inspiratory effort breathing He/O2 with that breathing medical air, with or without pressure support, across a range of adult, obstructive disease patterns. Methods Patient breathing was simulated using a dual-chamber mechanical test lung, with the breathing compartment connected to an ICU ventilator operated in NIV mode with medical air or He/O2 (78/22 or 65/35%). Parabolic or linear resistances were inserted at the inlet to the breathing chamber. Breathing chamber compliance was also varied. The inspiratory effort was assessed for the different gas mixtures, for three breathing patterns, with zero pressure support (simulating unassisted spontaneous breathing), and with varying levels of pressure support. Results Inspiratory effort increased with increasing resistance and decreasing compliance. At a fixed resistance and compliance, inspiratory effort increased with increasing minute ventilation, and decreased with increasing pressure support. For parabolic resistors, inspiratory effort was lower for He/O2 mixtures than for air, whereas little difference was measured for nominally linear resistance. Relatively small differences in inspiratory effort were measured between the two He/O2 mixtures. Used in combination, reductions in inspiratory effort provided by He/O2 and pressure support were additive. Conclusions The reduction in inspiratory effort afforded by breathing He/O2 is strongly dependent on the severity and type of airway obstruction. Varying helium concentration between 78% and 65% has small impact on inspiratory effort, while combining He/O2 with pressure support provides an additive reduction in inspiratory effort

  16. Bench experiments comparing simulated inspiratory effort when breathing helium-oxygen mixtures to that during positive pressure support with air.

    PubMed

    Martin, Andrew R; Katz, Ira M; Jenöfi, Katharina; Caillibotte, Georges; Brochard, Laurent; Texereau, Joëlle

    2012-10-03

    Inhalation of helium-oxygen (He/O2) mixtures has been explored as a means to lower the work of breathing of patients with obstructive lung disease. Non-invasive ventilation (NIV) with positive pressure support is also used for this purpose. The bench experiments presented herein were conducted in order to compare simulated patient inspiratory effort breathing He/O2 with that breathing medical air, with or without pressure support, across a range of adult, obstructive disease patterns. Patient breathing was simulated using a dual-chamber mechanical test lung, with the breathing compartment connected to an ICU ventilator operated in NIV mode with medical air or He/O2 (78/22 or 65/35%). Parabolic or linear resistances were inserted at the inlet to the breathing chamber. Breathing chamber compliance was also varied. The inspiratory effort was assessed for the different gas mixtures, for three breathing patterns, with zero pressure support (simulating unassisted spontaneous breathing), and with varying levels of pressure support. Inspiratory effort increased with increasing resistance and decreasing compliance. At a fixed resistance and compliance, inspiratory effort increased with increasing minute ventilation, and decreased with increasing pressure support. For parabolic resistors, inspiratory effort was lower for He/O2 mixtures than for air, whereas little difference was measured for nominally linear resistance. Relatively small differences in inspiratory effort were measured between the two He/O2 mixtures. Used in combination, reductions in inspiratory effort provided by He/O2 and pressure support were additive. The reduction in inspiratory effort afforded by breathing He/O2 is strongly dependent on the severity and type of airway obstruction. Varying helium concentration between 78% and 65% has small impact on inspiratory effort, while combining He/O2 with pressure support provides an additive reduction in inspiratory effort. In addition, breathing He/O2 alone may

  17. Comparing nasal packing with trans-septal suturing following septoplasty: a randomized clinical trial.

    PubMed

    Dadgarnia, Mohammadhossein; Meybodian, Mojtaba; Karbasi, Akbar; Baradaranfar, Mohammadhossein; Atighechi, Saeid; Zand, Vahid; Vaziribozorg, Sedighe

    2017-09-01

    It has been shown that nasal packing after septoplasty is associated with several complications. Our aim was to compare post-septoplasty nasal packing and trans-septal suturing, in terms of complications and outcome of operation. This randomized clinical trial was performed on patients with deviated nasal septum who were candidates for septoplasty. Patients were visited three times after operation (on the first 48 h, first week, and third post-operative month). Participants were checked for having common complications. Rhinomanometric evaluation was performed to measure nasal air flow and airway resistance, as indicators of operation efficacy, both prior to and after surgery. A total of 72 patients were allocated into the two trial arms. Patients in nasal pack group reported higher pain scores on the first 48 h (P < 0.001) and one week after surgery (P < 0.001). Epiphora (P = 0.028), sleep disturbance (P = 0.012), and dyspnea (P < 0.001) were also more commonly observed in patients using nasal pack. Objective evaluation of bleeding demonstrated that more severe bleeding occurred in patients with trans-septal sutures (P = 0.001). No differences were found comparing the indices of rhinomanometry between the two groups. Using trans-septal sutures after septoplasty compared to nasal packing, might be associated with lower frequencies of several specific complications and a lower rate of patients' discomfort. Nevertheless, increase in the risk of bleeding and hematoma was noted in the trans-septal suture group. No differences were observed between the nasal air flow and resistance of patients in the two groups.

  18. Extubation success in premature infants with respiratory distress syndrome treated with bi-level nasal continuous positive airway pressure versus nasal intermittent positive pressure ventilation.

    PubMed

    Thomas, Patricia E; LeFlore, Judy

    2013-01-01

    Infants born prematurely with respiratory distress syndrome are at high risk for complications from mechanical ventilation. Strategies are needed to minimize their days on the ventilator. The purpose of this study was to compare extubation success rates in infants treated with 2 different types of continuous positive airway pressure devices. A retrospective cohort study design was used. Data were retrieved from electronic medical records for patients in a large, metropolitan, level III neonatal intensive care unit. A sample of 194 premature infants with respiratory distress syndrome was selected, 124 of whom were treated with nasal intermittent positive pressure ventilation and 70 with bi-level variable flow nasal continuous positive airway pressure (bi-level nasal continuous positive airway pressure). Infants in both groups had high extubation success rates (79% of nasal intermittent positive pressure ventilation group and 77% of bi-level nasal continuous positive airway pressure group). Although infants in the bi-level nasal continuous positive airway pressure group were extubated sooner, there was no difference in duration of oxygen therapy between the 2 groups. Promoting early extubation and extubation success is a vital strategy to reduce complications of mechanical ventilation that adversely affect premature infants with respiratory distress syndrome.

  19. Assessment of nasalance and nasality in patients with a repaired cleft palate.

    PubMed

    Sinko, Klaus; Gruber, Maike; Jagsch, Reinhold; Roesner, Imme; Baumann, Arnulf; Wutzl, Arno; Denk-Linnert, Doris-Maria

    2017-07-01

    In patients with a repaired cleft palate, nasality is typically diagnosed by speech language pathologists. In addition, there are various instruments to objectively diagnose nasalance. To explore the potential of nasalance measurements after cleft palate repair by NasalView ® , we correlated perceptual nasality and instrumentally measured nasalance of eight speech items and determined the relationship between sensitivity and specificity of the nasalance measures by receiver-operating characteristics (ROC) analyses and AUC (area under the curve) computation for each single test item and specific item groups. We recruited patients with a primarily repaired cleft palate receiving speech therapy during follow-up. During a single day visit, perceptive and instrumental assessments were obtained in 36 patients and analyzed. The individual perceptual nasality was assigned to one of four categories; the corresponding instrumental nasalance measures for the eight specific speech items were expressed on a metric scale (1-100). With reference to the perceptual diagnoses, we observed 3 nasal and one oral test item with high sensitivity. However, the specificity of the nasality indicating measures was rather low. The four best speech items with the highest sensitivity provided scores ranging from 96.43 to 100%, while the averaged sensitivity of all eight items was below 90%. We conclude that perceptive evaluation of nasality remains state of the art. For clinical follow-up, instrumental nasalance assessment can objectively document subtle changes by analysis of four speech items only. Further studies are warranted to determine the applicability of instrumental nasalance measures in the clinical routine, using discriminative items only.

  20. The effects of respiratory muscle training on peak cough flow in patients with Parkinson's disease: a randomized controlled study.

    PubMed

    Reyes, Alvaro; Castillo, Adrián; Castillo, Javiera; Cornejo, Isabel

    2018-05-01

    To compare the effects of an inspiratory versus and expiratory muscle-training program on voluntary and reflex peak cough flow in patients with Parkinson disease. A randomized controlled study. Home-based training program. In all, 40 participants with diagnosis of Parkinson's disease were initially recruited in the study and randomly allocated to three study groups. Of them, 31 participants completed the study protocol (control group, n = 10; inspiratory training group, n = 11; and expiratory training group, n = 10) Intervention: The inspiratory and expiratory group performed a home-based inspiratory and expiratory muscle-training program, respectively (five sets of five repetitions). Both groups trained six times a week for two months using a progressively increased resistance. The control group performed expiratory muscle training using the same protocol and a fixed resistance. Spirometric indices, maximum inspiratory pressure, maximum expiratory pressure, and peak cough flow during voluntary and reflex cough were assessed before and at two months after training. The magnitude of increase in maximum expiratory pressure ( d = 1.40) and voluntary peak cough flow ( d = 0.89) was greater for the expiratory muscle-training group in comparison to the control group. Reflex peak cough flow had a moderate effect ( d = 0.27) in the expiratory group in comparison to the control group. Slow vital capacity ( d = 0.13) and forced vital capacity ( d = 0.02) had trivial effects in the expiratory versus the control group. Two months of expiratory muscle-training program was more beneficial than inspiratory muscle-training program for improving maximum expiratory pressure and voluntary peak cough flow in patients with Parkinson's disease.

  1. Noise levels of neonatal high-flow nasal cannula devices--an in-vitro study.

    PubMed

    König, Kai; Stock, Ellen L; Jarvis, Melanie

    2013-01-01

    Excessive ambient noise levels have been identified as a potential risk factor for adverse outcome in very preterm infants. Noise level measurements for continuous positive airway pressure (CPAP) devices demonstrated that these constantly exceed current recommendations. The use of high-flow nasal cannula (HFNC) as an alternative non-invasive ventilation modality has become more popular in recent years in neonatal care. To study noise levels of two HFNC devices commonly used in newborns. As a comparison, noise levels of a continuous flow CPAP device were also studied. In-vitro study. The noise levels of two contemporary HFNC devices (Fisher & Paykel NHF™ and Vapotherm Precision Flow®) and one CPAP device (Dräger Babylog® 8000 plus) were measured in the oral cavity of a newborn manikin in an incubator in a quiet environment. HFNC flows of 4-8 l/min and CPAP pressures of 4-8 cm H2O were applied. The CPAP flow was set at 8 l/min as per unit practice. Vapotherm HFNC generated the highest noise levels, measuring 81.2-91.4 dB(A) with increasing flow. Fisher & Paykel HFNC noise levels were between 78.8 and 81.2 dB(A). The CPAP device generated the lowest noise levels between 73.9 and 77.4 dB(A). Both HFNC devices generated higher noise levels than the CPAP device. All noise levels were far above current recommendations of the American Academy of Pediatrics. In light of the long duration of non-invasive respiratory support of very preterm infants, less noisy devices are required to prevent the potentially adverse effects of continuing excessive noise exposure in the neonatal intensive care unit. Copyright © 2013 S. Karger AG, Basel.

  2. [Exercise-induced inspiratory stridor. An important differential diagnosis of exercise-induced asthma].

    PubMed

    Christensen, Pernille; Thomsen, Simon Francis; Rasmussen, Niels; Backer, Vibeke

    2007-11-19

    Recent studies suggest that exercise-induced inspiratory stridor (EIIS) is an important and often overlooked differential diagnosis of exercise-induced asthma. EIIS is characterised by astma-like symptoms, but differs by inspiratory limitation, fast recovery, and a lack of effect of inhaled bronchodilators. The prevalence of EIIS is reported to be 5-27%, and affects both children and adults. The pathophysiology, the pathogenesis, and the treatment of the condition are not yet clarified. At present, a population-based study is being conducted in order to address these points.

  3. Inspiratory muscle performance in endurance-trained elderly males during incremental exercise.

    PubMed

    Chlif, Mehdi; Keochkerian, David; Temfemo, Abdou; Choquet, Dominique; Ahmaidi, Said

    2016-07-01

    The aim of this study was to compare the inspiratory muscle performance during an incremental exercise of twelve fit old endurance-trained athletes (OT) with that of fit young athletes (YT) and healthy age-matched controls (OC). The tension-time index (TT0.1) was determined according to the equation TT0.1=P0.1/PImax×ti/ttot, where P0.1 is the mouth occlusion pressure, PImax the maximal inspiratory pressure and ti/ttot the duty cycle. For a given VCO2, OT group displayed P0.1, P0.1/PImax ratio, TT0.1 and effective impedance of the respiratory muscle values which were lower than OC group and higher than YT group. At maximal exercise, P0.1/PImax ratio and TT0.1 was still lower in the OT group than OC group and higher than YT group. This study showed lower inspiratory muscle performance attested by a higher (TT0.1) during exercise in the OT group than YT group, but appeared to be less marked in elderly men having performed lifelong endurance training compared with sedentary elderly subjects. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. MP29-02 reduces nasal hyperreactivity and nasal mediators in patients with house dust mite-allergic rhinitis.

    PubMed

    Kortekaas Krohn, I; Callebaut, I; Alpizar, Y A; Steelant, B; Van Gerven, L; Skov, P S; Kasran, A; Talavera, K; Wouters, M M; Ceuppens, J L; Seys, S F; Hellings, P W

    2018-05-01

    Nasal hyperreactivity (NHR) is an important clinical feature of allergic rhinitis (AR). The efficacy of MP29-02 (azelastine hydrochloride (AZE) and fluticasone propionate [FP]) nasal spray on local inflammatory mediators and NHR in AR is unknown. We tested if MP29-02 decreases inflammatory mediators and NHR in AR and if this effect is due to restoration of nasal epithelial barrier function. A 4-week double-blinded placebo-controlled trial with MP29-02 treatment was conducted in 28 patients with house dust mite (HDM) AR. The presence of NHR was evaluated by measuring reduction in nasal flow upon cold dry air exposure. The effects of AZE ± FP on barrier integrity and airway inflammation were studied in a murine model of HDM-induced NHR and on reduced activation of murine sensory neurons and human mast cells. MP29-02 but not placebo reduced NHR (P < .0001 vs P = .21), levels of substance P (P = .026 vs P = .941), and β-hexosaminidase (P = .036 vs P = .632) in human nasal secretions. In wild-type C57BL6 mice, the reduction in β-hexosaminidase levels (P < .0001) by AZE + FP treatment upon HDM challenge was found in parallel with a decreased transmucosal passage (P = .0012) and completely reversed eosinophilic inflammation (P = .0013). In vitro, repeated applications of AZE + FP desensitized sensory neurons expressing the transient receptor potential channels TRPA1 and TRPV1. AZE + FP reduced MC degranulation to the same extent as AZE alone. MP29-02 treatment reduces inflammatory mediators and NHR in AR. The effects of AZE + FP on MC degranulation, nasal epithelial barrier integrity, and TRP channels provide novel insights into the pathophysiology of allergic rhinitis. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  5. Nasal Anatomy and Function.

    PubMed

    Patel, Ruchin G

    2017-02-01

    The nose is a complex structure important in facial aesthetics and in respiratory physiology. Nasal defects can pose a challenge to reconstructive surgeons who must re-create nasal symmetry while maintaining nasal function. A basic understanding of the underlying nasal anatomy is thus necessary for successful nasal reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Island composite nasal flap for nasal dorsum skin defects.

    PubMed

    Skitarelić, Neven; Mladina, Ranko; Mraovic, Boris; Simurina, Tatjana; Skitarelić, Nataa; Vuković, Katarina

    2009-08-01

    Skin defects on the nasal dorsum remain a challenge for the plastic surgeon. There are few local nasal flap options for the repair of proximally positioned nasal skin defects. During a 3-year period, 22 patients were treated after excision of skin cancer in the proximal two-thirds of the nose. Nine patients (41%) were female and 13 (59%) were male, with an average age of 69 years. All patients were operated on under local anesthesia. The average follow-up was 25 months. In all patients, after tumor ablation, the skin defect was closed with an island composite nasal skin flap. Pathohistologic analysis confirmed that the margins of the removed tumor were free of malignant cells. Six patients (27.3%) had squamous cell and 16 (72.7%) had basal cell carcinoma. There was no total or partial flap loss. None of the patients has suffered from recurrence of the tumor. The island composite nasal flap is a reliable technique for the closure of proximal nasal skin defects. Complications in the elevation of the island composite flap were rare, and the final result was acceptable.

  7. Measuring and Characterizing the Human Nasal Cycle

    PubMed Central

    Kahana-Zweig, Roni; Geva-Sagiv, Maya; Weissbrod, Aharon; Secundo, Lavi; Soroker, Nachum; Sobel, Noam

    2016-01-01

    Nasal airflow is greater in one nostril than in the other because of transient asymmetric nasal passage obstruction by erectile tissue. The extent of obstruction alternates across nostrils with periodicity referred to as the nasal cycle. The nasal cycle is related to autonomic arousal and is indicative of asymmetry in brain function. Moreover, alterations in nasal cycle periodicity have been linked to various diseases. There is therefore need for a tool allowing continuous accurate measurement and recording of airflow in each nostril separately. Here we provide detailed instructions for constructing such a tool at minimal cost and effort. We demonstrate application of the tool in 33 right-handed healthy subjects, and derive several statistical measures for nasal cycle characterization. Using these measures applied to 24-hour recordings we observed that: 1: subjects spent slightly longer in left over right nostril dominance (left = 2.63 ± 0.89 hours, right = 2.17 ± 0.89 hours, t(32) = 2.07, p < 0.05), 2: cycle duration was shorter in wake than in sleep (wake = 2.02 ± 1.7 hours, sleep = 4.5 ± 1.7 hours, (t(30) = 5.73, p < 0.0001). 3: slower breathing was associated with a more powerful cycle (the extent of difference across nostrils) (r = 0.4, p < 0.0001), and 4: the cycle was influenced by body posture such that lying on one side was associated with greater flow in the contralateral nostril (p < 0.002). Finally, we provide evidence for an airflow cycle in each nostril alone. These results provide characterization of an easily obtained measure that may have diagnostic implications for neurological disease and cognitive state. PMID:27711189

  8. The Allergic Rhinitis Clinical Investigator Collaborative (AR-CIC): verification of nasal allergen challenge procedures in a study utilizing an investigational immunotherapy for cat allergy.

    PubMed

    Neighbour, Helen; Soliman, Mena; Steacy, Lisa M; Hickey, Pascal; Forbes, Beth; Larché, Mark; Ellis, Anne K

    2018-01-01

    The Allergic Rhinitis Clinical Investigator Collaborative (AR-CIC) is a network of experienced Allergic Rhinitis (AR) researchers developing better research tools based on the nasal allergen challenge (NAC). A key objective of such is the ability to detect efficacy in a small population. AR-CIC sought to test its NAC protocol as a secondary objective in two small mechanistic research trials of a novel form of immunotherapy [Cat Peptide Antigen Desensitisation (Cat-PAD)] for which efficacy had previously been demonstrated. The primary objective (not presented here) was to identify potential biomarkers of efficacy for peptide immunotherapy, and this provided an ideal opportunity to corroborate the NAC protocol. We aim to clinically validate the AR-CIC NAC methodology in a pooled analysis of secondary endpoints measured in two open label mechanistic studies of cat allergic participants treated with Cat-PAD. Cat allergic AR sufferers with ongoing cat exposure were included. Participants had to demonstrate a total nasal symptom score (TNSS) of at least 8 (max 12) and/or achieve a reduction in peak nasal inspiratory flow (PNIF) of ≥ 50% during a screening titrated NAC. Eligible participants then underwent a baseline NAC visit with the allergen dose that produced a positive challenge at screening, followed by four monthly injections of 6 nmol Cat-PAD. A follow up NAC visit documented changes in nasal response 1 month following the completion of treatment. Nineteen subjects completed the study protocol in the two studies combined. Four injections of Cat-PAD resulted in a significant reduction in TNSS responses generated via NAC following allergen challenge (15 min p  < 0.05, 30 min p  < 0.05, 1 h p  < 0.01, 2 h p  < 0.05). There was modest correlation between symptom scores and PNIF measurements. This study supports the validity of the AR-CIC's optimised NAC protocol for conducting research of the potential efficacy of novel therapeutics in multi

  9. The need for an objective measure in septorhinoplasty surgery: are we any closer to finding an answer?

    PubMed

    Andrews, P J; Choudhury, N; Takhar, A; Poirrier, A L; Jacques, T; Randhawa, P S

    2015-12-01

    To assess the reliability of nasal inspiratory peak flow (NIPF) in providing a clinically accurate objective measure following functional septorhinoplasty by comparing it to the validated disease-specific quality-of-life questionnaire, SNOT-22. Studies so far have demonstrated poor correlation between bilateral NIPF and symptom-specific nasal questionnaires following septorhinoplasty. To perform a prospective comparative analysis between NIPF and the validated disease-specific quality-of-life questionnaire SNOT-22 and to determine whether a correlation exists following septorhinoplasty surgery. The Royal National Throat Nose and Ear Hospital, London. A total of 122 patients (78 males, 44 females; mean age 33.5 ± 12.2 years) were recruited from the senior authors rhinology clinic and underwent functional septorhinoplasty surgery. Preoperative and postoperative nasal inspiratory peak flow (NIPF) measurements were performed in addition to the completion of three subjective quality-of-life and symptom assessment tool questionnaires; Sinonasal Outcome Test 22 (SNOT-22), Nasal Obstruction Symptom Evaluation (NOSE) and Visual Analogue Scale (VAS: 0-10). The mean preoperative NIPF was 88.2 L/min, and the postoperative value was 101.6 L/min and showed a significant improvement following surgery (P = 0.0064). The mean total SNOT-22 score improved significantly from 48.6 to 26.6 (P < 0.0001); the NOSE score from 14.1 to 6.6 (P < 0.0001); and the Visual Analogue Scale (VAS) blockage score from 6.9 to 3.2 (P < 0.0001). All individual domains assessed showed improvements postoperatively, but no correlation was found between the NIPF and SNOT-22 score. Equally, we did not find a correlation between NIPF and the symptom-specific NOSE questionnaire and the nasal blockage domain on the Visual Analogue Scale (VAS) scale. We have demonstrated that NIPF does not correlate with the SNOT-22 disease-specific questionnaire, although both outcomes significantly improve postoperatively. At

  10. On the improvement of nasal breathing following mid-face osteotomies, and possible reasons for the phenomenon.

    PubMed

    Götzfried, H F; Masing, H

    1984-02-01

    In the great majority of patients with hypoplasia of the middle third of the face, the surgical advancement or displacement of the maxilla results in a subjective improvement in nasal breathing, which can also be verified. This is due to an increase in the volume of the nasal skeleton and/or in the nasolabial angle, which improves nasal ventilation. These operations have virtually no effect on endonasal obstructions to flow, which, in order further to improve nasal breathing, should be dealt with separately.

  11. Influence of cooling face masks on nasal air conditioning and nasal geometry.

    PubMed

    Lindemann, J; Hoffmann, T; Koehl, A; Walz, E M; Sommer, F

    2017-06-01

    Nasal geometries and temperature of the nasal mucosa are the primary factors affecting nasal air conditioning. Data on intranasal air conditioning after provoking the trigeminal nerve with a cold stimulus simulating the effects of an arctic condition is still missing. The objective was to investigate the influence of skin cooling face masks on nasal air conditioning, mucosal temperature and nasal geometry. Standardized in vivo measurements of intranasal air temperature, humidity and mucosal temperature were performed in 55 healthy subjects at defined detection sites before and after wearing a cooling face mask. Measurements of skin temperature, rhinomanometry and acoustic rhinometry were accomplished. After wearing the face mask the facial skin temperature was significantly reduced. Intranasal air temperature did not change. Absolute humidity and mucosal temperature increased significantly. The acoustic rhinometric results showed a significant increase of the volumes and the cross-sectional areas. There was no change in nasal airflow. Nasal mucosal temperature, humidity of inhaled air, and volume of the anterior nose increased after application of a cold face mask. The response is mediated by the trigeminal nerve. Increased mucosal temperatures as well as changes in nasal geometries seem to guarantee sufficient steady intranasal nasal air conditioning.

  12. Reduced nasal growth after primary nasal repair combined with cleft lip surgery.

    PubMed

    Yoshimura, Y; Okumoto, T; Iijima, Y; Inoue, Y

    2015-11-01

    Nasal growth after cleft lip surgery with or without primary nasal repair was evaluated using lateral cephalograms. In 14 patients who underwent simultaneous nasal repair with primary cleft lip repair and 12 patients without simultaneous nasal repair, lateral cephalograms were obtained at 5 and 10 years of age. Lateral cephalograms of normal Japanese children were used as a control. At 5 years of age, there were significant differences in the nasal height and columellar angle among the three groups. Children without simultaneous nasal repair had shorter noses with more upward tilt of the columella compared with the controls, while children with simultaneous nasal repair had much shorter noses and more upward tilt than those without repair. At 10 years of age, the children without simultaneous nasal repair showed no differences from the control group, while those with simultaneous repair still had shorter noses and more upward tilt of the columella. These findings suggest that performing nasal repair at the same time as primary cleft lip surgery has an adverse influence on the subsequent growth of the nose. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. [Endoscopic treatment of small osteoma of nasal sinuses manifested as nasal and facial pain].

    PubMed

    Li, Yu; Zheng, Tianqi; Li, Zhong; Deng, Hongyuan; Guo, Chaoxian

    2015-12-01

    To discuss the clinical features, diagnosis and endoscopic surgical intervention for small steoma of nasal sinuses causing nasal and facial pain. A retrospective review was performed on 21 patients with nasal and facial pain caused by small osteoma of nasal sinuses, and nasal endoscopic surgery was included in the treatment of all cases. The nasal and facial pain of all the patients was relieved. Except for one ase exhibiting periorbital bruise after operation, the other patients showed no postoperative complications. Nasal and facial pain caused by small osteoma of nasal sinuses was clinically rare, mostly due to the neuropathic pain of nose and face caused by local compression resulting from the expansion of osteoma. Early diagnosis and operative treatment can significantly relieve nasal and facial pain.

  14. Effects of nasal septum perforation repair on nasal airflow: An analysis using computational fluid dynamics on preoperative and postoperative three-dimensional models.

    PubMed

    Nomura, Tsutomu; Ushio, Munetaka; Kondo, Kenji; Kikuchi, Shigeru

    2018-10-01

    The purpose of this research is to examine the changes in nasal airflow dynamics before and after the nasal perforation repair. Three dimensional (3D) models of the nasal cavity before and after septal perforation repair was reconstructed using preoperative and postoperative computed tomography (CT) images of a patient. The numerical simulation was carried out using ANSYS CFX V15.0. Pre- and post-operative models were compared by their velocity, pressure (P), pressure gradient (PG), wall shear (WS), shear strain rate (SSR) and turbulence kinetic energy (TKE) in three plains. In the post-operative state, the cross flows disappeared. In preoperative state, there were areas showing high PG, WS, SSR at the posterior border of the perforation, which exactly correspond to the area showing erosive mucosa on endoscopic inspection of the patient. In postoperative state, such high PG, WS and SSR areas disappeared. High TKEs also disappeared after surgery. The effects of septal perforation repair on airflow dynamics were evaluated using computer fluid dynamics (CFD). High WS, PG and SSR observed at the edge of the septal perforation may be related to the clinical symptom such as nasal bleeding and pain. TKE was considered to cause nasal symptom. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Oxymetazoline Nasal Spray

    MedlinePlus

    ... is recommended by a doctor. Children 6 to 12 years of age should use oxymetazoline nasal spray carefully and under adult supervision. Oxymetazoline is in a class of medications called nasal decongestants. It works by narrowing the blood vessels in the nasal passages.

  16. Validation of polyvinylidene fluoride nasal sensor to assess nasal obstruction in comparison with subjective technique.

    PubMed

    Roopa Manjunatha, G; Mahapatra, D Roy; Prakash, Surya; Rajanna, K

    2015-01-01

    The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14±5.87% and 48.85±5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33±10.54% and LN: 32.24±11.54%). Moderate correlation was observed in healthy group (r=-0.710, p<0.001 for RN and r=-0.651, p<0.001 for LN), and moderate to strong correlation in patient group (r=-0.751, p<0.01 for RN and r=-0.885, p<0.0001 for LN). PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Estimation of inhalation flow profile using audio-based methods to assess inhaler medication adherence.

    PubMed

    Taylor, Terence E; Lacalle Muls, Helena; Costello, Richard W; Reilly, Richard B

    2018-01-01

    Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be

  18. Estimation of inhalation flow profile using audio-based methods to assess inhaler medication adherence

    PubMed Central

    Lacalle Muls, Helena; Costello, Richard W.; Reilly, Richard B.

    2018-01-01

    Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be

  19. Effects of inspiratory pause on CO2 elimination and arterial PCO2 in acute lung injury

    PubMed Central

    Devaquet, Jérôme; Jonson, Björn; Niklason, Lisbet; Si Larbi, Anne-Gaëlle; Uttman, Leif; Aboab, Jérôme; Brochard, Laurent

    2008-01-01

    A high respiratory rate associated with the use of small tidal volumes, recommended for acute lung injury (ALI), shortens time for gas diffusion in the alveoli. This may decrease CO2 elimination. We hypothesized that a post-inspiratory pause could enhance CO2 elimination and reduce PaCO2 by reducing dead space in ALI. In 15 mechanically ventilated patients with ALI and hypercapnia, a 20% post-inspiratory pause (Tp20) was applied during a period of 30 min between two ventilation periods without post-inspiratory pause (Tp0). Other parameters were kept unchanged. The single breath test for CO2 was recorded every 5 minutes to measure tidal CO2 elimination (VtCO2), airway dead space (VDaw) and slope of the alveolar plateau. PaO2, PaCO2, physiological and alveolar dead space (VDphys, VDalv) were determined at the end of each 30 minute period. The post-inspiratory pause, 0.7±0.2 s, induced on average less than 0.5 cm H2O of intrinsic PEEP. During Tp20, VtCO2 increased immediately by 28±10% (14±5 ml per breath compared to 11±4 for Tp0) and then decreased without reaching the initial value within 30 minutes. The addition of a post-inspiratory pause decreased significantly VDaw by 14% and VDphys by 11% with no change in VDalv. During Tp20, the slope of alveolar plateau initially fell to 65±10 % of baseline value and continued to decrease. Tp20 induced a 10±3% decrease in PaCO2 at 30 minutes (from 55±10 to 49±9 mmHg, p<0.001) with no significant variation in PaO2. Post-inspiratory pause has a significant influence on CO2 elimination when small tidal volumes are used during mechanical ventilation for ALI. PMID:18801962

  20. Pre-operative inspiratory muscle training preserves postoperative inspiratory muscle strength following major abdominal surgery - a randomised pilot study.

    PubMed

    Kulkarni, S R; Fletcher, E; McConnell, A K; Poskitt, K R; Whyman, M R

    2010-11-01

    The aim of this pilot study was to assess the effect of pre-operative inspiratory muscle training (IMT) on respiratory variables in patients undergoing major abdominal surgery. Respiratory muscle strength (maximum inspiratory [MIP] and expiratory [MEP] mouth pressure) and pulmonary functions were measured at least 2 weeks before surgery in 80 patients awaiting major abdominal surgery. Patients were then allocated randomly to one of four groups (Group A, control; Group B, deep breathing exercises; Group C, incentive spirometry; Group D, specific IMT). Patients in groups B, C and D were asked to train twice daily, each session lasting 15 min, for at least 2 weeks up to the day before surgery. Outcome measurements were made immediately pre-operatively and postoperatively. In groups A, B and C, MIP did not increase from baseline to pre-operative assessments. In group D, MIP increased from 51.5 cmH(2)O (median) pre-training to 68.5 cmH(2)O (median) post-training pre-operatively (P < 0.01). Postoperatively, groups A, B and C showed a fall in MIP from baseline (P < 0.01, P < 0.01) and P = 0.06, respectively). No such significant reduction in postoperative MIP was seen in group D (P = 0.36). Pre-operative specific IMT improves MIP pre-operatively and preserves it postoperatively. Further studies are required to establish if this is associated with reduced pulmonary complications.

  1. Reprint of "Learning to breathe? Feedforward regulation of the inspiratory motor drive".

    PubMed

    Zaman, Jonas; Van den Bergh, Omer; Fannes, Stien; Van Diest, Ilse

    2014-12-01

    Claims have been made that breathing is in part controlled by feedforward regulation. In a classical conditioning paradigm, we investigated anticipatory increases in the inspiratory motor drive as measured by inspiratory occlusion pressure (P100). In an acquisition phase, an experimental group (N = 13) received a low-intensity resistive load (5 cmH2O/l/s) for three consecutive inspirations as Conditioned Stimulus (CS), preceding a load of a stronger intensity (20 cmH2O/l/s) for three subsequent inspirations as unconditioned stimulus (US). The control group (N = 11) received the low-intensity load for six consecutive inspirations. In a post-acquisition phase both groups received the low-intensity load for six consecutive inspirations. Responses to the CS-load only differed between groups during the first acquisition trials and a strong increase in P100 during the US-loads was observed, which habituated across the experiment. Our results suggest that the disruption caused by adding low to moderate resistive loads to three consecutive inspirations results in a short-lasting anticipatory increase in inspiratory motor drive. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Introduction of Infant Flow nasal continuous airway pressure as the standard of practice in Poland: the initial 2-year experience.

    PubMed

    Swietliński, Janusz; Bober, Klaudiusz; Gajewska, Elzbieta; Helwich, Ewa; Lauterbach, Ryszard; Manowska, Małgorzata; Maruszewski, Bohdan; Szczapa, Jerzy; Hubicki, Lech

    2007-03-01

    The aim of this prospective study was to evaluate whether a change in the standard of newborn care for respiratory insufficiency by widely introducing more aggressive use of nasal continuous airway pressure (nCPAP) and including Infant Flow technology would result in satisfactory outcomes. Prospectively defined analysis. Fifty-seven secondary and tertiary care neonatal centers in Poland. Patients were 1,299 newborns. None. We carried out a prospectively defined analysis of 1,299 newborns included in the program between August 1, 2003, and April 30, 2005. The inclusion criterion was the occurrence of symptoms of respiratory failure irrespective of its etiology. Respiratory support was provided with the use of the Infant Flow Advance Driver. The analysis was made on data from prospectively designed questionnaires completed following each infant's treatment. Infants were placed into categories based on clinical indication for use. The primary end point was avoiding tracheal intubation. A high rate of acceptance of the new practice was observed across the substantial demographic and clinical diversity of newborns. Tracheal intubation was avoided in 78% of infants treated electively with nCPAP. Of those being weaned from mechanical ventilation, 61.2% were successfully weaned. Related complications were low (1.4% pneumothorax, 12% nasal injuries). The new method of nCPAP with Infant Flow was adopted as standard practice in Poland. We monitored its safety and effectiveness over a 2-yr period and found it to be safe and effective as implemented. Additional research is still needed to determine the optimum patient population, strategy for use, and devices.

  3. [Dexpanthenol nasal spray in comparison to dexpanthenol nasal ointment. A prospective, randomised, open, cross-over study to compare nasal mucociliary clearance].

    PubMed

    Verse, T; Klöcker, N; Riedel, F; Pirsig, W; Scheithauer, M O

    2004-07-01

    Recent technical developments in metered pump systems allow the production and use of preservative-free nasal products. The aim of the current study is to compare the tolerability of a preservative-free dexpanthenol (5%) nasal spray with that of the established dexpanthenol (5%) nasal ointment, also without preservatives. The main outcome measure was in vivo mucociliary clearance. Mucociliary clearance was assessed by saccharin migration time in 20 volunteers. Wash-out phases were 7 days and the spray or ointment was always applied 20 min before the saccharin test. The study was designed to test for non-inferiority. Saccharin migration time was slightly longer after ointment administration, however, these were not significantly different to nasal spray. The saccharin migration time showed a significant correlation with the age of the volunteers. The upper confidence limit of dexpanthenol nasal spray was markedly less than that of the ointment. Therefore, dexpanthenol nasal spray is at least equal to if not better than dexpanthenol nasal ointment. Due to its ease of administration, preservative-free dexpanthenol nasal spray offers a valuable therapeutic alternative.

  4. Nasal Cancer

    MedlinePlus

    ... the way to your throat as you breathe. Cancer of the nasal cavity and paranasal sinuses is ... be like those of infections. Doctors diagnose nasal cancer with imaging tests, lighted tube-like instruments that ...

  5. Restorative procedures in disturbed function of the upper airways - nasal breathing

    PubMed Central

    Mlynski, Gunter

    2005-01-01

    These days, functional rhinosurgery is almost always taken to mean the improvement of nasal airflow. However, air should not only pass through the nose without obstruction. It needs to be warmed, moistened and filtered. This requires sufficient air/mucous membrane contact by spreading airflow over the entire turbinate region, as well as regulation of nasal airway resistance and the degree of turbulence within the nasal cycle. These factors are not considered enough in the concept of functional rhinosurgery. There cannot be a rigid concept for functional/aesthetic rhinosurgery, the surgical procedure must be adapted to the individual anatomy and pathology. In spite of this, it must be clear (based on evidence) which surgical steps can solve a functional problem of the nose in the long term. This paper cannot explain evidence-based treatment strategies to restore nasal respiratory function because in all branches of rhinosurgery, there are no prospective studies available with a sufficiently high sample size and long-term results objectivized by functional diagnosis. Studies available on septal surgery show better results for SP after Cottle than for SMR after Killian. However, the success rate of a 70 to 80% improvement in nasal breathing is not satisfactory. The incidence of postoperative, dry nasal mucosa is also too high. The task of rhinology is to stress the functional side of rhinosurgery more. This includes preoperative analysis of the causes of disturbed respiratory function using the functional diagnosis methods available, the use of evidence-based surgical techniques and postoperative, objectivized quality control. More research needs to be done on the physiology and pathophysiology of nasal airflow as well as on the effect of rhinosurgery on airflow. Numerical flow simulation can contribute greatly to this because the effects of shape changes on the flow can be visualized. Methods need to be developed which can be used for routine, diagnostic recording of

  6. [Does heliox administered by low-flow nasal cannula improve respiratory distress in infants with respiratory syncytial virus acute bronchiolitis? A randomized controlled trial].

    PubMed

    Seliem, Wael; Sultan, Amira M

    2018-04-04

    The aim of our study is to evaluate whether the use of heliox (79:21) delivered through a low flow nasal cannula would improve respiratory distress in infants with acute bronchiolitis caused by respiratory syncytial virus. We have conducted a prospective randomized controlled study. All patients fulfilled inclusion criteria were randomized to either heliox (79:21) or air via NC at 2 L/min for a continuous 24hours. Measurements were taken at baseline, after 2hours and at the end of the 24hours. We have included 104 patients into our study. The MCA-S did not show any significant difference between the two groups after 2hours 4.3 vs. 4.1 (P =.78), or at 24hours after 4.2 vs. 4.3 (P =.89). No difference was found in the proportion of participants progressed to MV, n-CPAP or oxygen via nasal cannula (RR 1.0, 0.86 and 0.89) (P= 1.0, .77 and .73). There was no notable reduction in length of treatment in Heliox group 2.42 days vs. 2.79 days in air group P =.65. The in oxygen saturation, PaO 2 , and PaCO 2 did not to have any statistical difference between the two studied groups after 2hours and 24hours of treatment. Our data showed absence of any beneficial effect of heliox in a concentration (79:21) delivered through low flow nasal cannula in terms of respiratory distress improvement in infants with RSV acute bronchiolitis. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  7. Nasal Physiology

    MedlinePlus

    ... Anatomy Virtual Anatomy Disclosure Statement Printer Friendly Nasal Physiology Jeremiah A. Alt, MD, PhD Noam Cohen, MD, ... control the inflammation. CONCLUSION An understanding of the physiology of the nose is critical to understand nasal ...

  8. [Effect of absorption enhancers on nasal ginsenoside Rg1 delivery and its nasal ciliotoxicity].

    PubMed

    Chen, Xin-mei; Zhu, Jia-bi; Sun, Wei-dong; Zhang, Li-jian

    2006-02-01

    The enhancing activity and safety of several absorption enhancers were evaluated as potential nasal absorption enhancers to increase intranasal absorption of ginsenoside Rg1. Nasal circulatory perfusion test in vivo had been employed to investigate the effect of absorption enhancers for nasal mucosa absorption of ginsenoside Rgl in rats. The safety of the absorption enhancers were evaluated by testing cilia movement of the in situ toad palate model, the hemolysis of erythrocyte membrane of the rabbit, leaching of protein and LDH from the mice nasal mucosa and the effect on cilia structural and specific cellular changes of nasal mucosa. Absorption enhancers were necessary to facilitate ginsenoside Rg1 absorption by nasal mucosa. Among the absorption enhancers 1% sodium deoxycholate had great effect to facilite ginsenoside Rgl absorption by nasal mucosa; 1% dipotassium glycyrrhizinate and 1% azone had moderate effect to facilitate ginsenoside Rg1 absorption by nasal mucosa; 1% Tween-80, 2% beta-cyclodextrin, 0.5% borneol (dissolved in paraffin liquid), 0.5% chitosan, 5% hydroxypropyl-beta-cyclodextrin and 0.1% EDTA had low effect to facilitate ginsenoside Rgl absorption by nasal mucosa. 1% sodium deoxycholate, 1% azone and 1% dipotassium glycyrrhizinate had serious nasal toxicity; 1% Tween-80, 2% beta-cyclodextrin, 5% hydroxypropyl-beta-cyclodextrin had moderate nasal toxicity; 0.5% borneol (dissolved in paraffin liquid), 0.5% chitosan and 0.1% EDTA have little nasal toxicity. 0.5% borneol and 0.5% chitosan were the promising candidates having a good balance between enhancing activity and safety for nasal ginsenoside Rg1 delivery.

  9. Nasal osteoma in a dairy cow: a combined clinical, imaging and histopathological approach to diagnosis.

    PubMed

    Wuersch, K; Bischoff, M; Thoma, R; Matter, M S

    2009-01-01

    An 8-year-old Brown Swiss dairy cow was presented with unilateral epistaxis and mild inspiratory stridor. At that time endoscopic examination revealed a smooth-surfaced mass within the left nasal cavity. Biopsy samples were collected and a diagnosis of fibrosarcoma was made. Eighteen months later the animal developed severe respiratory distress that led to difficulties in feeding and consequently to emaciation and a dramatic drop in milk production. The cow was humanely destroyed and submitted for post-mortem examination. The head was subject to further investigation by radiography, computed tomography and magnetic resonance imaging. These techniques revealed a non-infiltrative, well-circumscribed mass of both radiodense and heterogeneously intense structures. Histopathological examination revealed a mass consisting of well-differentiated and interlacing bone trabeculae lined by osteoblasts and multinucleated osteoclasts. In contrast to the initial diagnosis, the later diagnostic approaches supported the diagnosis of osteoma.

  10. [Effect of inspiratory muscle training on muscle strength and quality of life in patients with chronic airflow limitation: a randomized controlled trial].

    PubMed

    Serón, P; Riedemann, P; Muñoz, S; Doussoulin, A; Villarroel, P; Cea, X

    2005-11-01

    Chronic airflow limitation (CAL) is a significant cause of illness and death. Inspiratory muscle training has been described as a technique for managing CAL. The aim of the present study was to evaluate the effectiveness of inspiratory muscle training on improving physiological and functional variables. Randomized controlled trial in which 35 patients with CAL were assigned to receive either an experimental (n=17) or control (n=18) intervention. The experimental intervention consisted of 2 months of inspiratory muscle training using a device that administered a resistive load of 40% of maximal static inspiratory mouth pressure (PImax). Inspiratory muscle strength, exercise tolerance, respiratory function, and quality of life were assessed. Significant improvement in inspiratory muscle strength was observed in the experimental training group (P=.02). All patients improved over time in both groups (P<.001). PImax increased by 8.9 cm H2O per month of training. Likewise, the health-related quality of life scores improved by 0.56 points. Use of a threshold loading device is effective for strengthening inspiratory muscles as measured by PImax after the first month of training in patients with CAL. The long-term effectiveness of such training and its impact on quality of life should be studied in a larger number of patients.

  11. Nasal computed tomography.

    PubMed

    Kuehn, Ned F

    2006-05-01

    Chronic nasal disease is often a challenge to diagnose. Computed tomography greatly enhances the ability to diagnose chronic nasal disease in dogs and cats. Nasal computed tomography provides detailed information regarding the extent of disease, accurate discrimination of neoplastic versus nonneoplastic diseases, and identification of areas of the nose to examine rhinoscopically and suspicious regions to target for biopsy.

  12. Effect of hyperinflation on inspiratory function of the diaphragm.

    PubMed

    Minh, V D; Dolan, G F; Konopka, R F; Moser, K M

    1976-01-01

    The inspiratory efficiency of the diaphragm during unilateral and bilateral phrenic stimulation (UEPS and BEPS) with constant stimulus was studied in seven dogs from FRC to 120% TLC. Alveolar pressures (PAl) were recorded during relaxation, BEPS and UEPS at each lung volume in the closed respiratory system. From the PAl-lung volume curves, tidal volume (VT), and pressure developed by the diaphragm (Pmus) were derived. Results are summarized below. a) Hyperinflation impaired the inspiratory efficiency of the diaphragm which behaved as an expiratory muscle beyond the lung volume of 103.7% TLC (Vinef). b) The diaphragm during UEPS became expiratory at the same Vinef as during (BEPS. C) The VT-lung volume relationship was linear during BEPS, allowing simple quantitation of VT loss with hyperinflation and prediction of Vinef. d) With only one phrenic nerve stimulated, the functional loss is less pronounced in VT than in Pmus, as compared to BEPS, indicating that the respiratory system was more compliant during UEPS than BEPS. This compliance difference from UEPS to BEPS diminished with severe hyperinflation.

  13. Bayes to the Rescue: Continuous Positive Airway Pressure Has Less Mortality Than High-Flow Oxygen.

    PubMed

    Modesto I Alapont, Vicent; Khemani, Robinder G; Medina, Alberto; Del Villar Guerra, Pablo; Molina Cambra, Alfred

    2017-02-01

    The merits of high-flow nasal cannula oxygen versus bubble continuous positive airway pressure are debated in children with pneumonia, with suggestions that randomized controlled trials are needed. In light of a previous randomized controlled trial showing a trend for lower mortality with bubble continuous positive airway pressure, we sought to determine the probability that a new randomized controlled trial would find high-flow nasal cannula oxygen superior to bubble continuous positive airway pressure through a "robust" Bayesian analysis. Sample data were extracted from the trial by Chisti et al, and requisite to "robust" Bayesian analysis, we specified three prior distributions to represent clinically meaningful assumptions. These priors (reference, pessimistic, and optimistic) were used to generate three scenarios to represent the range of possible hypotheses. 1) "Reference": we believe bubble continuous positive airway pressure and high-flow nasal cannula oxygen are equally effective with the same uninformative reference priors; 2) "Sceptic on high-flow nasal cannula oxygen": we believe that bubble continuous positive airway pressure is better than high-flow nasal cannula oxygen (bubble continuous positive airway pressure has an optimistic prior and high-flow nasal cannula oxygen has a pessimistic prior); and 3) "Enthusiastic on high-flow nasal cannula oxygen": we believe that high-flow nasal cannula oxygen is better than bubble continuous positive airway pressure (high-flow nasal cannula oxygen has an optimistic prior and bubble continuous positive airway pressure has a pessimistic prior). Finally, posterior empiric Bayesian distributions were obtained through 100,000 Markov Chain Monte Carlo simulations. In all three scenarios, there was a high probability for more death from high-flow nasal cannula oxygen compared with bubble continuous positive airway pressure (reference, 0.98; sceptic on high-flow nasal cannula oxygen, 0.982; enthusiastic on high-flow

  14. Perception of Better Nasal Patency Correlates with Increased Mucosal Cooling after Surgery for Nasal Obstruction

    NASA Astrophysics Data System (ADS)

    Garcia, Guilherme; Sullivan, Corbin; Frank-Ito, Dennis; Kimbell, Julia; Rhee, John

    2014-11-01

    Nasal airway obstruction (NAO) is a common health problem with 340,000 patients undergoing surgery annually in the United States. Traditionally, otolaryngologists have focused on airspace cross-sectional areas and nasal resistance to airflow as objective measures of nasal patency, but neither of these variables correlated consistently with patients' symptoms. Given that the sensation of nasal airflow is also associated with mucosal cooling (i.e., heat loss) during inspiration, we investigated the correlation between the sensation of nasal obstruction and mucosal cooling in 10 patients before and after NAO surgery. Three-dimensional models of the nasal anatomy were created based on pre- and post-surgery computed tomography scans. Computational fluid dynamics (CFD) simulations were conducted to quantify nasal resistance and mucosal cooling. Patient-reported symptoms were measured by a visual analog scale and the Nasal Obstruction Symptom Evaluation (NOSE), a disease-specific quality of life questionnaire. Our results revealed that the subjective sensation of nasal obstruction correlated with both nasal resistance and heat loss, but the strongest correlation was between the NOSE score and the nasal surface area where heat flux exceeds 50 W /m2 . In conclusion, a significant post-operative increase in mucosal cooling correlates well with patients' perception of better nasal patency after NAO surgery.

  15. [Clinical effects of nasal glucocorticoid on amelioration of nasal obstruction in patients with persistent non-allergic rhinitis].

    PubMed

    Sail, Giyab A; Zuo, Ke-jun; Xu, Geng

    2009-09-01

    To observe the efficacy of nasal glucocorticoid continuously used for 12 weeks on nasal obstruction in patients with persistent non-allergic rhinitis (PNAR). The changes of nasal obstruction, nasal resistance, nasal mucous membrane and quality of life in 47 patients with PNAR were observed. The efficacy of nasal glucocorticoid (Mometasone Furoate Nasal Spray, MFNS 200 microg/day) on patients with PNAR was evaluated. The results of nasal glucocorticoid (MFNS) continuously used for 12 weeks demonstrated: (1) After treatment, the nasal obstruction, nasal discharge, nasal obstruction related dizziness, headache, hyposmia, daily life activity, whole body fatigue, mental status were significantly improved (P < 0.05). (2) Nasal resistance showed significant amelioration (pre-treatment = 0.28 +/- 0.10, post- treatment = 0.16 +/- 0.05; F = 91.471, P < 0.05). (3) SF-36 questionnaire revealed that role physical, bodily pain, general health, role emotional had significant amelioration (P < 0.01). (4) SNOT-20 questionnaire revealed that the defatigation, impaired concentration, pinch the nose, nasal discharging into the throat, sleep quality had significant amelioration (P < 0.01). (5) Continued treatment for 12 weeks was better than 4 weeks, continued treatment had good effect. The study shows that nasal glucocorticoid improved the nasal obstruction, nasal resistance, nasal mucous membrane and quality of life in patients with PNAR.

  16. Transdiaphragmatic pressure and neural respiratory drive measured during inspiratory muscle training in stable patients with chronic obstructive pulmonary disease.

    PubMed

    Wu, Weiliang; Zhang, Xianming; Lin, Lin; Ou, Yonger; Li, Xiaoying; Guan, Lili; Guo, Bingpeng; Zhou, Luqian; Chen, Rongchang

    2017-01-01

    Inspiratory muscle training (IMT) is a rehabilitation therapy for stable patients with COPD. However, its therapeutic effect remains undefined due to the unclear nature of diaphragmatic mobilization during IMT. Diaphragmatic mobilization, represented by transdiaphragmatic pressure (Pdi), and neural respiratory drive, expressed as the corrected root mean square (RMS) of the diaphragmatic electromyogram (EMGdi), both provide vital information to select the proper IMT device and loads in COPD, therefore contributing to the curative effect of IMT. Pdi and RMS of EMGdi (RMSdi%) were measured and compared during inspiratory resistive training and threshold load training in stable patients with COPD. Pdi and neural respiratory drive were measured continuously during inspiratory resistive training and threshold load training in 12 stable patients with COPD (forced expiratory volume in 1 s ± SD was 26.1%±10.2% predicted). Pdi was significantly higher during high-intensity threshold load training (91.46±17.24 cmH 2 O) than during inspiratory resistive training (27.24±6.13 cmH 2 O) in stable patients with COPD, with P <0.01 for each. Significant difference was also found in RMSdi% between high-intensity threshold load training and inspiratory resistive training (69.98%±16.78% vs 17.26%±14.65%, P <0.01). We concluded that threshold load training shows greater mobilization of Pdi and neural respiratory drive than inspiratory resistive training in stable patients with COPD.

  17. Inspiratory muscle training in difficult to wean patients: work it harder, make it better, do it faster, makes us stronger.

    PubMed

    Nava, Stefano; Fasano, Luca

    2011-01-01

    Weaning from prolonged mechanical ventilation is a complex, time-consuming process that involves the loss of force/generating capacity of the inspiratory muscle. In their study 'Inspiratory muscle strength training improves the outcome in failure to wean patients: a randomized trial', Martin and colleagues showed that the use of an inspiratory muscle strength program increased the maximal inspiratory pressure and improved weaning success compared to a control group. The study was performed mainly in post-surgical patients, however, and the results, therefore, may not be generalizable to other subsets of patients, such as those with chronic obstructive pulmonary disease or congestive heart failure. Indeed, the study applied so-called 'strength training' and not 'endurance training', which may be more appropriate in certain circumstances.

  18. Daily inspiratory muscle training lowers blood pressure and vascular resistance in healthy men and women.

    PubMed

    DeLucia, Claire M; De Asis, Roxanne M; Bailey, E Fiona

    2018-02-01

    What is the central question of this study? What impact does inspiratory muscle training have on systemic vascular resistance, cardiac output and baroreflex sensitivity in adult men and women? What is the main finding and its importance? Inspiratory muscle training exerts favorable effects on blood pressure, vascular resistance and perception of stress. This exercise format is well-tolerated and equally effective whether implemented in men or women. Previous work has shown that inspiratory muscle training (IMT) lowers blood pressure after a mere 6 weeks, identifying IMT as a potential therapeutic intervention to prevent or treat hypertension. Here, we explore the effects of IMT on respiratory muscle strength and select cardiovascular parameters in recreationally active men and women. Subjects were randomly assigned to IMT (n = 12, 75% maximal inspiratory pressure) or sham training (n = 13, 15% maximal inspiratory pressure) groups and underwent a 6-week intervention comprising 30 breaths day -1 , 5 days week -1 . Pre- and post-training measures included maximal inspiratory pressure and resting measures of blood pressure, cardiac output, heart rate, spontaneous cardiac baroreflex sensitivity and systemic vascular resistance. We evaluated psychological and sleep status via administration of the Cohen-Hoberman inventory of physical symptoms and the Epworth sleepiness scale. Male and female subjects in the IMT group showed declines in systolic/diastolic blood pressures (-4.3/-3.9 mmHg, P < 0.025) and systemic vascular resistance (-3.5 mmHg min l -1 , P = 0.008) at week 6. There was no effect of IMT on cardiac output (P = 0.722), heart rate (P = 0.795) or spontaneous cardiac baroreflex sensitivity (P = 0.776). The IMT subjects also reported fewer stress-related symptoms (pre- versus post-training, 12.5 ± 8.5 versus 7.2 ± 9.7, P = 0.025). Based on these results, we suggest that a short course of IMT confers significant respiratory and

  19. Effect of nitric oxide synthase inhibitor on increase in nasal mucosal blood flow induced by sensory and parasympathetic nerve stimulation in rats.

    PubMed

    Ogawa, Fumio; Hanamitsu, Masakazu; Ayajiki, Kazuhide; Aimi, Yoshinari; Okamura, Tomio; Shimizu, Takeshi

    2010-06-01

    Neural control of nasal blood flow (NBF) has not been systematically investigated. The aim of the present study was to evaluate the effect of electrical stimulation of both sensory and parasympathetic nerves innervating the nasal mucosal arteries on NBF in rats. In anesthetized rats, nasociliary (sensory) nerves and postganglionic (parasympathetic) nerves derived from the right sphenopalatine ganglion were electrically stimulated. We measured NBF with a laser-Doppler flowmeter. The nerve stimulation increased NBF on both sides and increased the mean arterial blood pressure. The increase in NBF was larger on the ipsilateral side than on the contralateral side. Hexamethonium bromide, a ganglion blocker, abolished the stimulation-induced pressure effect and the increase in NBF on the contralateral side, but did not abolish the increase in NBF on the ipsilateral side. The remaining increase in NBF was abolished by N(G)-nitro-L-arginine, a nitric oxide synthase inhibitor. Histochemical analysis with nicotinamide adenine dinucleotide phosphate-diaphorase showed neuronal nitric oxide synthase-containing nerves that innervate nasal mucosal arteries. Nitric oxide released from parasympathetic nitrergic nerves may contribute to an increase in NBF in rats. The afferent impulses induced by sensory nerve stimulation may lead to an increase in mean arterial blood pressure that is partly responsible for the increase in NBF.

  20. Design of experiments to optimize an in vitro cast to predict human nasal drug deposition.

    PubMed

    Shah, Samir A; Dickens, Colin J; Ward, David J; Banaszek, Anna A; George, Chris; Horodnik, Walter

    2014-02-01

    Previous studies showed nasal spray in vitro tests cannot predict in vivo deposition, pharmacokinetics, or pharmacodynamics. This challenge makes it difficult to assess deposition achieved with new technologies delivering to the therapeutically beneficial posterior nasal cavity. In this study, we determined best parameters for using a regionally divided nasal cast to predict deposition. Our study used a model suspension and a design of experiments to produce repeatable deposition results that mimic nasal deposition patterns of nasal suspensions from the literature. The seven-section (the nozzle locator, nasal vestibule, front turbinate, rear turbinate, olfactory region, nasopharynx, and throat filter) nylon nasal cast was based on computed tomography images of healthy humans. It was coated with a glycerol/Brij-35 solution to mimic mucus. After assembling and orienting, airflow was applied and nasal spray containing a model suspension was sprayed. After disassembling the cast, drug depositing in each section was assayed by HPLC. The success criteria for optimal settings were based on nine in vivo studies in the literature. The design of experiments included exploratory and half factorial screening experiments to identify variables affecting deposition (angles, airflow, and airflow time), optimization experiments, and then repeatability and reproducibility experiments. We found tilt angle and airflow time after actuation affected deposition the most. The optimized settings were flow rate of 16 L/min, postactuation flow time of 12 sec, a tilt angle of 23°, nozzle angles of 0°, and actuation speed of 5 cm/sec. Neither cast nor operator caused significant variation of results. We determined cast parameters to produce results resembling suspension nasal sprays in the literature. The results were repeatable and unaffected by operator or cast. These nasal spray parameters could be used to assess deposition from new devices or formulations. For human deposition

  1. Respiratory mechanics by least squares fitting in mechanically ventilated patients: application on flow-limited COPD patients.

    PubMed

    Volta, Carlo A; Marangoni, Elisabetta; Alvisi, Valentina; Capuzzo, Maurizia; Ragazzi, Riccardo; Pavanelli, Lina; Alvisi, Raffaele

    2002-01-01

    Although computerized methods of analyzing respiratory system mechanics such as the least squares fitting method have been used in various patient populations, no conclusive data are available in patients with chronic obstructive pulmonary disease (COPD), probably because they may develop expiratory flow limitation (EFL). This suggests that respiratory mechanics be determined only during inspiration. Eight-bed multidisciplinary ICU of a teaching hospital. Eight non-flow-limited postvascular surgery patients and eight flow-limited COPD patients. Patients were sedated, paralyzed for diagnostic purposes, and ventilated in volume control ventilation with constant inspiratory flow rate. Data on resistance, compliance, and dynamic intrinsic positive end-expiratory pressure (PEEPi,dyn) obtained by applying the least squares fitting method during inspiration, expiration, and the overall breathing cycle were compared with those obtained by the traditional method (constant flow, end-inspiratory occlusion method). Our results indicate that (a) the presence of EFL markedly decreases the precision of resistance and compliance values measured by the LSF method, (b) the determination of respiratory variables during inspiration allows the calculation of respiratory mechanics in flow limited COPD patients, and (c) the LSF method is able to detect the presence of PEEPi,dyn if only inspiratory data are used.

  2. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    PubMed

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  3. Surgical management of nasal obstruction.

    PubMed

    Moche, Jason A; Palmer, Orville

    2012-05-01

    The proper evaluation of the patient with nasal obstruction relies on a comprehensive history and physical examination. Once the site of obstruction is accurately identified, the patient may benefit from a trial of medical management. At times however, the definitive treatment of nasal obstruction relies on surgical management. Recognizing the nasal septum, nasal valve, and turbinates as possible sites of obstruction and addressing them accordingly can dramatically improve a patient's nasal breathing. Conservative resection of septal cartilage, submucous reduction of the inferior turbinate, and structural grafting of the nasal valve when appropriate will provide the optimal improvement in nasal airflow and allow for the most stable results. Copyright © 2012. Published by Elsevier Inc.

  4. Snoring and Nasal Congestion

    MedlinePlus

    ... treat the various causes of nasal congestion include: Topical nasal steroid spray Topical nasal antihistamine spray Oral antibiotic (in case of ... include more than just the decrease in oxygen levels at night during the apnea episodes. They also ...

  5. A novel and well tolerated mite allergoid subcutaneous immunotherapy: evidence of clinical and immunologic efficacy

    PubMed Central

    Roger, Albert; Depreux, Nathalie; Jurgens, Yani; Heath, Matthew D; Garcia, Gloria; Skinner, Murray A

    2014-01-01

    Allergy to house dust mite is one of the most common causes of allergic rhinitis. A novel tyrosine-adsorbed, modified allergen product, Acarovac Plus, developed for the treatment of perennial mite allergy seeks to address the underlying cause of allergic rhinitis in this instance. One of two dosing regimens may be used, either the Conventional Regimen or the Cluster Regimen. We sought to compare the efficacy and safety of a specific immunotherapy, developed for the treatment of perennial mite allergy, administered under a Conventional and Clustered dosing schedule in patients with persistent allergic rhinitis. Thirty adult patients, between 18 and 65 years old, with allergic rhinitis and/or asthma secondary to hypersensitivity to Dermatophagoides pteronyssinus were administered with either conventional or cluster initial regime, with a final visit one week after the last dose administration. The efficacy to the Conventional and Cluster regimens was measured using a Nasal Challenge Test monitoring clinical symptoms and peak nasal inspiratory flow. Total IgE, serum-specific inmunoglobulins (IgE and IgG4) to Dermatophagoides pteronyssinus and relevant cytokines (IFN-γ, IL-4, IL-5, IL-10 and IL-13) were assessed. A Satisfaction Questionnaire (TSQM) was completed after each patient's final visit. The tolerability of the vaccine was assessed monitoring adverse reactions. No adverse events were recorded in either conventional or cluster regime. The specific Nasal Challenge Test led to a decrease in symptom scores and a significant decrease in mean nasal peak inspiratory flow drop was recorded in both dosing regimen groups. A significant increase in IgG4-specific antibody titres was assessed. No significant changes were observed in concentrations of total IgE, specific IgE or cytokines (IFN-γ, IL-4, IL-5, IL-10 and IL-13). Patients declared themselves most satisfied in relation to “Secondary effects”, with high overall satisfaction in both groups. Cluster and

  6. Inspiratory muscle training improves respiratory muscle strength, functional capacity and quality of life in patients with chronic kidney disease: a systematic review.

    PubMed

    de Medeiros, Ana Irene Carlos; Fuzari, Helen Kerlen Bastos; Rattesa, Catarina; Brandão, Daniella Cunha; de Melo Marinho, Patrícia Érika

    2017-04-01

    Does inspiratory muscle training improve respiratory muscle strength, functional capacity, lung function and quality of life of patients with chronic kidney disease? Does inspiratory muscle training improve these outcomes more than breathing exercises? Systematic review and meta-analysis of randomised trials. People with chronic kidney disease undergoing dialysis treatment. The primary outcomes were: maximal inspiratory pressure, maximal expiratory pressure, and distance covered on the 6-minute walk test. The secondary outcomes were: forced vital capacity, forced expiratory volume in the first second (FEV 1 ), and quality of life. The search identified four eligible studies. The sample consisted of 110 participants. The inspiratory muscle training used a Threshold ® or PowerBreathe ® device, with a load ranging from 30 to 60% of the maximal inspiratory pressure and lasting from 6 weeks to 6 months. The studies showed moderate to high risk of bias, and the quality of the evidence was rated low or very low, due to the studies' methodological limitations. The meta-analysis showed that inspiratory muscle training significantly improved maximal inspiratory pressure (MD 23 cmH 2 O, 95% CI 16 to 29) and the 6-minute walk test distance (MD 80m, 95% CI 41 to 119) when compared with controls. Significant benefits in lung function and quality of life were also identified. When compared to breathing exercises, significant benefits were identified in maximal expiratory pressure (MD 6 cmH 2 O, 95% CI 2 to 10) and FEV 1 (MD 0.24litres 95% CI 0.14 to 0.34), but not maximal inspiratory pressure or forced vital capacity. In patients with chronic renal failure on dialysis, inspiratory muscle training with a fixed load significantly improves respiratory muscle strength, functional capacity, lung function and quality of life. The evidence for these benefits may be influenced by some sources of bias. PROSPERO (CRD 42015029986). [de Medeiros AIC, Fuzari HKB, Rattesa C, Brandão DC, de

  7. Evaluation of nasal IgA secretion in normal subjects by nasal spray and aspiration.

    PubMed

    Fujimoto, Chisa; Kido, Hiroshi; Sawabuchi, Takako; Mizuno, Dai; Hayama, Masaki; Yanagawa, Hiroaki; Takeda, Noriaki

    2009-06-01

    Nasal washing (NW) is a popular method for collecting human nasal lavage fluid. However, for NW the subject must be trained, and the method is unsuitable for field studies on untrained subjects. To overcome this problem, we have developed an easy and painless method, a nasal spray and aspiration (NSA) method. This method is different from NW in that the nasal cavity is misted over with saline, and the nasal lavage fluid is aspirated from the nostrils through a silicon tube. First, nasal lavage fluid was obtained twice by NSA with an interval of a week between lavages to evaluate intraindividual variability, and the IgA and protein levels in the nasal lavage fluid were measured by enzyme-linked immunosorbent assay and bicinchoninic acid assay, respectively. Next, the IgA value determined by NSA was compared with that by NW in another 12 normal subjects 2 days after NSA. In 10 normal subjects, mean volume of saline sprayed into the nose was 0.46+/-0.15 ml (mean+/-S.D.). Mean volume of aspirated nasal lavage fluid containing both sprayed saline and nasal secretion was 0.44+/-0.37 ml. The mean IgA level/mg protein in the nasal lavage fluid determined by NSA was 112+/-18 microg/mg protein at the first and 99+/-20 at the second times of measurement, being highly reproducible. The mean value by NSA was 114+/-19 microg/mg protein, being almost the same as that by NW of 99+/-27. These findings suggest that the IgA level/mg protein in nasal lavage fluid determined by NSA instead of NW might be useful for assessing the variability of nasal IgA secretion.

  8. Perceiving nasal patency through mucosal cooling rather than air temperature or nasal resistance.

    PubMed

    Zhao, Kai; Blacker, Kara; Luo, Yuehao; Bryant, Bruce; Jiang, Jianbo

    2011-01-01

    Adequate perception of nasal airflow (i.e., nasal patency) is an important consideration for patients with nasal sinus diseases. The perception of a lack of nasal patency becomes the primary symptom that drives these patients to seek medical treatment. However, clinical assessment of nasal patency remains a challenge because we lack objective measurements that correlate well with what patients perceive. The current study examined factors that may influence perceived patency, including air temperature, humidity, mucosal cooling, nasal resistance, and trigeminal sensitivity. Forty-four healthy subjects rated nasal patency while sampling air from three facial exposure boxes that were ventilated with untreated room air, cold air, and dry air, respectively. In all conditions, air temperature and relative humidity inside each box were recorded with sensors connected to a computer. Nasal resistance and minimum airway cross-sectional area (MCA) were measured using rhinomanometry and acoustic rhinometry, respectively. General trigeminal sensitivity was assessed through lateralization thresholds to butanol. No significant correlation was found between perceived patency and nasal resistance or MCA. In contrast, air temperature, humidity, and butanol threshold combined significantly contributed to the ratings of patency, with mucosal cooling (heat loss) being the most heavily weighted predictor. Air humidity significantly influences perceived patency, suggesting that mucosal cooling rather than air temperature alone provides the trigeminal sensation that results in perception of patency. The dynamic cooling between the airstream and the mucosal wall may be quantified experimentally or computationally and could potentially lead to a new clinical evaluation tool.

  9. Accuracy of Perceptual and Acoustic Methods for the Detection of Inspiratory Loci in Spontaneous Speech

    PubMed Central

    Wang, Yu-Tsai; Nip, Ignatius S. B.; Green, Jordan R.; Kent, Ray D.; Kent, Jane Finley; Ullman, Cara

    2012-01-01

    The current study investigates the accuracy of perceptually and acoustically determined inspiratory loci in spontaneous speech for the purpose of identifying breath groups. Sixteen participants were asked to talk about simple topics in daily life at a comfortable speaking rate and loudness while connected to a pneumotach and audio microphone. The locations of inspiratory loci were determined based on the aerodynamic signal, which served as a reference for loci identified perceptually and acoustically. Signal detection theory was used to evaluate the accuracy of the methods. The results showed that the greatest accuracy in pause detection was achieved (1) perceptually based on the agreement between at least 2 of the 3 judges; (2) acoustically using a pause duration threshold of 300 ms. In general, the perceptually-based method was more accurate than was the acoustically-based method. Inconsistencies among perceptually-determined, acoustically-determined, and aerodynamically-determined inspiratory loci for spontaneous speech should be weighed in selecting a method of breath-group determination. PMID:22362007

  10. Functional anatomy of the nasal bones and adjacent structures. Consequences for nasal surgery.

    PubMed

    Popko, M; Verlinde-Schellekens, S A M W; Huizing, E H; Bleys, R L A W

    2018-03-01

    The periosteum of the nasal bones, the periosteal-perichondrial nasal envelope, and the cartilaginous support of the bony vault were studied in serial coronal sections of four human cadaver noses. To differentiate between the various tissue components, the sections were stained according to Mallory-Cason and Verhoeff-Van Gieson stain. The results demonstrated: 1. the presence of clearly distinguishable layers of the periosteum covering the nasal bones; 2. the presence of a continuous periosteal-perichondrial covering of the bony and cartilaginous nasal vaults; 3. the way the cartilaginous support of the bony vault is constructed. The findings described in the present study may have clinical relevance in nasal surgery.

  11. Comparison between Perceptual Assessments of Nasality and Nasalance Scores

    ERIC Educational Resources Information Center

    Brunnegard, Karin; Lohmander, Anette; van Doorn, Jan

    2012-01-01

    Background: There are different reports of the usefulness of the Nasometer[TM] as a complement to listening, often as correlation calculations between listening and nasalance measurements. Differences between findings have been attributed to listener experience and types of speech stimuli. Aims: To compare nasalance scores from the Nasometer with…

  12. Three-dimensional inspiratory flow in a double bifurcation airway model

    NASA Astrophysics Data System (ADS)

    Jalal, Sahar; Nemes, Andras; Van de Moortele, Tristan; Schmitter, Sebastian; Coletti, Filippo

    2016-09-01

    The flow in an idealized airway model is investigated for the steady inhalation case. The geometry consists of a symmetric planar double bifurcation that reflects the anatomical proportions of the human bronchial tree, and a wide range of physiologically relevant Reynolds numbers ( Re = 100-5000) is considered. Using magnetic resonance velocimetry, we analyze the three-dimensional fields of velocity and vorticity, along with flow descriptors that characterize the longitudinal and lateral dispersion. In agreement with previous studies, the symmetry of the flow partitioning is broken even at the lower Reynolds numbers, and at the second bifurcation, the fluid favors the medial branches over the lateral ones. This trend reaches a plateau around Re = 2000, above which the turbulent inflow results in smoothed mean velocity gradients. This also reduces the streamwise momentum flux, which is a measure of the longitudinal dispersion by the mean flow. The classic Dean-type counter-rotating vortices are observed in the first-generation daughter branches as a result of the local curvature. In the granddaughter branches, however, the secondary flows are determined by the local curvature only for the lower flow regimes ( Re ≤ 250), in which case the classic Dean mechanism prevails. At higher flow regimes, the field is instead dominated by streamwise vortices extending from the daughter into the medial granddaughter branches, where they rotate in the opposite direction with respect to Dean vortices. Circulation and secondary flow intensity show a similar trend as the momentum flux, increasing with Reynolds number up to Re = 2000 and then dropping due to turbulent dissipation of vorticity. The streamwise vortices interact both with each other and with the airway walls, and for Re > 500 they can become stronger in the medial granddaughter than in the upstream daughter branches. With respect to realistic airway models, the idealized geometry produces weaker secondary flows

  13. Formulation of a dry powder influenza vaccine for nasal delivery.

    PubMed

    Garmise, Robert J; Mar, Kevin; Crowder, Timothy M; Hwang, C Robin; Ferriter, Matthew; Huang, Juan; Mikszta, John A; Sullivan, Vincent J; Hickey, Anthony J

    2006-03-10

    The purpose of this research was to prepare a dry powder vaccine formulation containing whole inactivated influenza virus (WIIV) and a mucoadhesive compound suitable for nasal delivery. Powders containing WIIV and either lactose or trehalose were produced by lyophilization. A micro-ball mill was used to reduce the lyophilized cake to sizes suitable for nasal delivery. Chitosan flakes were reduced in size using a cryo-milling technique. Milled powders were sieved between 45 and 125 microm aggregate sizes and characterized for particle size and distribution, morphology, and flow properties. Powders were blended in the micro-ball mill without the ball. Lyophilization followed by milling produced irregularly shaped, polydisperse particles with a median primary particle diameter of approximately 21 microm and a yield of approximately 37% of particles in the 45 to 125 microm particle size range. Flow properties of lactose and trehalose powders after lyophilization followed by milling and sieving were similar. Cryo-milling produced a small yield of particles in the desired size range (<10%). Lyophilization followed by milling and sieving produced particles suitable for nasal delivery with different physicochemical properties as a function of processing conditions and components of the formulation. Further optimization of particle size and morphology is required for these powders to be suitable for clinical evaluation.

  14. Effect of Nasal Continuous Positive Pressure on the Nostrils of Patients with Sleep Apnea Syndrome and no Previous Nasal Pathology. Predictive Factors for Compliance.

    PubMed

    Aguilar, Francina; Cisternas, Ariel; Montserrat, Josep Maria; Àvila, Manuel; Torres-López, Marta; Iranzo, Alex; Berenguer, Joan; Vilaseca, Isabel

    2016-10-01

    To evaluate the effect of continuous positive airway pressure (CPAP) on the nostrils of patients with sleep apnea-hypopnea syndrome and its impact on quality of life, and to identify predictive factors for compliance. Longitudinal prospective study. Thirty-six consecutive patients evaluated before and 2 months after CPAP using the following variables: clinical (eye, nose and throat [ENT] symptoms, Epworth test, anxiety/depression scales, general and rhinoconjunctivitis-specific quality of life); anatomical (ENT examination, computed tomography); functional (auditive and Eustachian tube function, nasal flow, mucociliary transport); biological (nasal cytology); and polisomnographics. The sample was divided into compliers (≥4h/d) and non-compliers (<4h/d). A significant improvement was observed in daytime sleepiness (p=0.000), anxiety (P=.006), and depression (P=.023). Nasal dryness (P=.000), increased neutrophils in nasal cytology (P=.000), and deteriorating ciliary function were evidenced, particularly in compliers. No significant differences were observed in the other variables. Baseline sleepiness was the only factor predictive of compliance. CPAP in patients without previous nasal pathology leads to an improvement in a series of clinical parameters and causes rhinitis and airway dryness. Some ENT variables worsened in compliers. Sleepiness was the only prognostic factor for poor tolerance. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    PubMed Central

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A

    2018-01-01

    Purpose The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. Conclusion The TIRE measures of MIP, SMIP and ID have excellent test–retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP. PMID:29805255

  16. Perceiving Nasal Patency through Mucosal Cooling Rather than Air Temperature or Nasal Resistance

    PubMed Central

    Zhao, Kai; Blacker, Kara; Luo, Yuehao; Bryant, Bruce; Jiang, Jianbo

    2011-01-01

    Adequate perception of nasal airflow (i.e., nasal patency) is an important consideration for patients with nasal sinus diseases. The perception of a lack of nasal patency becomes the primary symptom that drives these patients to seek medical treatment. However, clinical assessment of nasal patency remains a challenge because we lack objective measurements that correlate well with what patients perceive.The current study examined factors that may influence perceived patency, including air temperature, humidity, mucosal cooling, nasal resistance, and trigeminal sensitivity. Forty-four healthy subjects rated nasal patency while sampling air from three facial exposure boxes that were ventilated with untreated room air, cold air, and dry air, respectively. In all conditions, air temperature and relative humidity inside each box were recorded with sensors connected to a computer. Nasal resistance and minimum airway cross-sectional area (MCA) were measured using rhinomanometry and acoustic rhinometry, respectively. General trigeminal sensitivity was assessed through lateralization thresholds to butanol. No significant correlation was found between perceived patency and nasal resistance or MCA. In contrast, air temperature, humidity, and butanol threshold combined significantly contributed to the ratings of patency, with mucosal cooling (heat loss) being the most heavily weighted predictor. Air humidity significantly influences perceived patency, suggesting that mucosal cooling rather than air temperature alone provides the trigeminal sensation that results in perception of patency. The dynamic cooling between the airstream and the mucosal wall may be quantified experimentally or computationally and could potentially lead to a new clinical evaluation tool. PMID:22022361

  17. Extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training: a randomized clinical trial.

    PubMed

    Cader, Samária Ali; de Souza Vale, Rodrigo Gomes; Zamora, Victor Emmanuel; Costa, Claudia Henrique; Dantas, Estélio Henrique Martin

    2012-01-01

    The purpose of this study was to evaluate the extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training (IMT) and identify predictors of successful weaning. Twenty-eight elderly intubated patients in an intensive care unit were randomly assigned to an experimental group (n = 14) that received conventional physiotherapy plus IMT with a Threshold IMT(®) device or to a control group (n = 14) that received only conventional physiotherapy. The experimental protocol for muscle training consisted of an initial load of 30% maximum inspiratory pressure, which was increased by 10% daily. The training was administered for 5 minutes, twice daily, 7 days a week, with supplemental oxygen from the beginning of weaning until extubation. Successful extubation was defined by the ventilation time measurement with noninvasive positive pressure. A vacuum manometer was used for measurement of maximum inspiratory pressure, and the patients' Tobin index values were measured using a ventilometer. The maximum inspiratory pressure increased significantly (by 7 cm H(2)O, 95% confidence interval [CI] 4-10), and the Tobin index decreased significantly (by 16 breaths/ min/L, 95% CI -26 to 6) in the experimental group compared with the control group. The Chi-squared distribution did not indicate a significant difference in weaning success between the groups (χ(2) = 1.47; P = 0.20). However, a comparison of noninvasive positive pressure time dependence indicated a significantly lower value for the experimental group (P = 0.0001; 95% CI 13.08-18.06). The receiver-operating characteristic curve showed an area beneath the curve of 0.877 ± 0.06 for the Tobin index and 0.845 ± 0.07 for maximum inspiratory pressure. The IMT intervention significantly increased maximum inspiratory pressure and significantly reduced the Tobin index; both measures are considered to be good extubation indices. IMT was associated with a reduction in noninvasive positive

  18. Impact of nasal septal perforations of varying sizes and locations on the warming function of the nasal cavity: A computational fluid-dynamics analysis of 5 cases.

    PubMed

    Li, Lifeng; Han, Demin; Zhang, Luo; Li, Yunchuan; Zang, Hongrui; Wang, Tong; Liu, Yingxi

    2016-09-01

    Patients with a nasal septal perforation often exhibit symptoms associated with disturbed airflow, which can have an adverse effect on the warming function of the nasal cavity. The impact of this effect is not fully understood. The warming function is an important factor in the maintenance of nasal physiology. We conducted a study to investigate the impact of septal perforations of various sizes and locations on the warming function during inspiration in 5 patients-3 men and 2 women, aged 25 to 47 years. Three-dimensional computed tomography and computational fluid dynamics were used to model the flux of communication and temperature, and differences among patients were compared. All 5 patients exhibited an impairment of their nasal warming function. As the size of the perforation increased, the flux of communication increased and the warming function decreased. Perforations located in an anterior position were associated with greater damage to the warming function than those in a posterior position. In patients with a large or anteriorly located perforation, airflow temperature in the nasopharynx was decreased. Our findings suggest that septal perforations not only induce airflow disturbance, but they also impair the nasal warming function. Further analysis of warming function is necessary to better explore flow mechanisms in patients with structural abnormalities.

  19. Comparison of Early-period Results of Nasal Splint and Merocel Nasal Packs in Septoplasty

    PubMed Central

    Bingöl, Fatih; Budak, Ali; Şimşek, Eda; Kılıç, Korhan; Bingöl, Buket Özel

    2017-01-01

    Objective Several types of nasal packs are used postoperatively in septoplasty. In this study, we compared two commonly used nasal packing materials, the intranasal septal splint with airway and Merocel tampon, in terms of pain, bleeding, nasal obstruction, eating difficulties, discomfort in sleep, and pain and bleeding during removal of packing in the early period. Methods The study group included 60 patients undergoing septoplasty. Patients were divided into two groups (n=30 in each group). An intranasal splint with airway was used for the patients in the first group after septoplasty, while Merocel nasal packing was used for the second group. Patients were investigated in terms of seven different factors - pain, bleeding while the tampon was in place, nasal obstruction, eating difficulties, night sleep, pain during removal of the nasal packing, and bleeding after removal of packing. Results There was no statistically significant difference between the groups in terms of pain 24 hours after operation (p=0.05), while visual analog scale (VAS) scores for nasal obstruction, night sleep, eating difficulties, and pain during packing removal were lower in the nasal splint group with a statistically significant difference (p<0.05). There was no statistically significant difference between the groups in terms of postoperative bleeding (p=0.23). Significantly less bleeding occurred during removal of the packing in the nasal splint group (p<0.05). Conclusion Our study indicates that the nasal splint was more comfortable and effective in terms of causing lesser bleeding and pain during removal of packing. PMID:29392071

  20. Nasalance measures in Cantonese-speaking women.

    PubMed

    Whitehill, T L

    2001-03-01

    To establish and evaluate stimulus materials for nasalance measurement in Cantonese speakers, to provide normative data for Cantonese-speaking women, and to evaluate session-to-session reliability of nasalance measures. One hundred forty-one Cantonese-speaking women with normal resonance who were students in the Department of Speech and Hearing Sciences, University of Hong Kong. Participants read aloud four speech stimuli: oral sentences, nasal sentences, an oral paragraph (similar to the Zoo Passage), and an oral-nasal paragraph (similar to the Rainbow Passage). Data were collected and analyzed using the Kay Nasometer 6200. Data collection was repeated for a subgroup of speakers (n = 28) on a separate day. Nasalance materials were evaluated by using statistical tests of difference and correlation. Group mean (standard deviation) nasalance scores for oral sentences, nasal sentences, oral paragraph, and oral-nasal paragraph were 16.79 (5.99), 55.67 (7.38), 13.68 (7.16), and 35.46 (6.22), respectively. There was a significant difference in mean nasalance scores for oral versus nasal materials. Correlations between stimuli were as expected, ranging from 0.43 to 0.91. Session-to-session reliability was within 5 points for over 95% of speakers for the oral stimuli but for less than 76% of speakers for the nasal and oral-nasal stimuli. Standard nasalance materials have been developed for Cantonese, and normative data have been established for Cantonese women. Evaluation of materials indicated acceptable differentiation between oral and nasal materials. Two stimuli (nasal sentences and oral paragraph) are recommended for future use. Comparison with findings from other languages showed similarities in scores; possible language-specific differences are discussed. Session-to-session reliability was poorer for nasal than oral stimuli.

  1. Nasal septal hematoma

    MedlinePlus

    ... medlineplus.gov/ency/article/001292.htm Nasal septal hematoma To use the sharing features on this page, please enable JavaScript. A nasal septal hematoma is a collection of blood within the septum ...

  2. Same Noses, Different Nasalance Scores: Data from Normal Subjects and Cleft Palate Speakers for Three Systems for Nasalance Analysis

    ERIC Educational Resources Information Center

    Bressmann, Tim; Klaiman, Paula; Fischbach, Simone

    2006-01-01

    Nasalance scores from the Nasometer, the NasalView and the OroNasal System were compared. The data was collected from 50 normal participants and 19 hypernasal patients with cleft palate. The Nasometer had the lowest nasalance scores for the non-nasal Zoo Passage and that the OroNasal System had the lowest nasalance scores for the Nasal Sentences.…

  3. Nasal hydropulsion.

    PubMed

    Elizabeth, Ashbaugh

    2013-08-01

    Intranasal tumors of dogs and cats pose a diagnostic and therapeutic challenge for the small animal practitioner. A simplified flushing technique to biopsy and debulk nasal tumors, that often results in immediate clinical relief for the patient is described. This technique can also be utilized to remove nasal foreign bodies. © 2013 Elsevier Inc. All rights reserved.

  4. Comparison between a Single-Channel Nasal Airflow Device and Oximetry for the Diagnosis of Obstructive Sleep Apnea

    PubMed Central

    Rofail, Lydia Makarie; Wong, Keith K.H.; Unger, Gunnar; Marks, Guy B.; Grunstein, Ronald R.

    2010-01-01

    Rationale: The most common single channel devices used for obstructive sleep apnea (OSA) screening are nasal airflow and oximetry. No studies have directly compared their role in diagnosing OSA at home. Study Objectives: To prospectively compare the diagnostic utility of home-based nasal airflow and oximetry to attended polysomnography (PSG) and to assess the diagnostic value of adding oximetry to nasal airflow for OSA. Design: Cross-sectional study Setting: Laboratory and home Participants: Sleep clinic patients with suspected OSA. Interventions: All patients had laboratory PSG and 2 sets of 3 consecutive nights on each device; nasal airflow (Flow Wizard, DiagnoseIT, Australia) and oximetry (Radical Set, Masimo, USA) at home in random order. Results: Ninety-eight of the 105 patients enrolled completed home monitoring. The accuracy of nasal airflow respiratory disturbance index (NF RDI) was not different from oximetry (ODI 3%) for diagnosing OSA (area under the ROC curve (AUC) difference, 0.04; 95% CI of difference −0.05 to 0.12; P = 0.43) over 3 nights of at-home recording. The accuracy of NF RDI was higher after 3 nights compared to one night (AUC difference, 0.05; 95% CI of difference, 0.01 to 0.08; P = 0.04). Addition of oximetry to nasal airflow did not increase the accuracy for predicting OSA compared to nasal airflow alone (P > 0.1). Conclusions: Nasal flow and oximetry have equivalent accuracy for diagnosing OSA in the home setting. Choice of device for home screening of sleep apnea may depend on logistical and service delivery issues. Citation: Makarie Rofail L; Wong KKH; Unger G; Marks GB; Grunstein RR. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. SLEEP 2010;33(8):1106-1114. PMID:20815194

  5. [Analysis of the PNIF measurement (Peak Nas Inspiratory Flow) in ECAP study (The Epidemiology of Allergic Diseases in Poland)].

    PubMed

    Modzelewska, Dominika; Krzych-Fałta, Edyta; Lusawa, Adam; Samoliński, Bolesław

    2012-01-01

    Measurement of PNIF is often used as a indicator in provocation studies or used for assessment the therapeutic effect of medicines. Unfortunately, there is a lack of norm for this parameter. Therefore, the aim of this study was to assess a few variables which are advisable to estimate the norm for PNIF measurements. The study was a part of the ECAP study (The Epidemiology of Allergic Diseases in Poland). Study group was selected randomly: children aged 6-7, 13-14 and adults. Subjects were inhabitants of 8 cities: Białystok, Gdańsk, Katowice, Kraków, Lublin, Poznań, Warszawa i Wrocław and one village district: zamojski and krasnystawski. PNIF level had been measured among qualified respondents by In-Check inspiratory flow meter manufactured by Clement. Clark. PNIF level was measured before and after application of Oxalin (0,05%) aimed at improve patency of nasal passages. The study was conducted three times, the highest value was noted. There were 4674 qualified subjects, of which 27,6% were children aged 6-7, 27,7%-children aged 13-14 and 44,7%-adults. Results were quantified by Statistica 10 programme and Microsoft Excel programme. Analysis were conducted in regards of sex, age, health status and study area. SEX: Statistically significant higher level of PNIF, as before as after application of medicine, were observed among man than woman. Average level of PNIF after application of medicine among adult man were 151,99 l/min (SD=61,73 l/min), boys aged 13-14-127,62 l/min (SD=53,0), boys aged 6-7- 54,44 l/min (SD=33,44 l/min). Average level of PNIF after application of medicine among adult woman were 119,31 l/min (SD= 45,71 l/min), girls aged 13-14- 109,13 l/min (SD=42,86 l/ min), girls aged 6-7- 61,35 l/min (SD= 31,56 l/min). AGE: There was observed statistically significant difference between age's groups. Average level of PNIF among adults were 131,91 l/min (SD=54,82 l/min), children aged 13-14- 118,68 l/min (SD=49,23 l/min), children aged 6-7- 64,27 l

  6. Ipratropium Nasal Spray

    MedlinePlus

    ... follow these steps: Remove the clear plastic dust cap and the safety clip from the nasal spray ... the other nostril. Replace the clear plastic dust cap and safety clip. If the nasal tip becomes ...

  7. Nasal fracture - aftercare

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000554.htm Nasal fracture - aftercare To use the sharing features on this ... that gives your nose its shape. A nasal fracture occurs when the bony part of your nose ...

  8. Nasal Wash Treatment

    MedlinePlus

    ... Guidelines Wash your hands. Make the nasal wash solution. Do not use tap water for the nasal ... Whichever water you use to make the saline solution, replace container or water at least weekly. To ...

  9. Beclomethasone Nasal Spray

    MedlinePlus

    ... the lining of the nose) after nasal polyp removal surgery. Beclomethasone nasal spray should not be used ... room temperature and away from excess heat and moisture (not in the bathroom).Unneeded medications should be ...

  10. Nasal Harmony in Aguaruna.

    ERIC Educational Resources Information Center

    Moon, Gui-Sun

    A discussion of the nasal harmony of Aguaruna, a language of the Jivaroan family in South America, approaches the subject from the viewpoint of generative phonology. This theory of phonology proposes an underlying nasal consonant, later deleted, that accounts for vowel nasalization. Complex rules that suppose a complex system of vowel and…

  11. External Nasal Neuralgia: A Neuropathic Pain Within the Territory of the External Nasal Nerve.

    PubMed

    García-Moreno, Héctor; Aledo-Serrano, Ángel; Gimeno-Hernández, Jesús; Cuadrado, María-Luz

    2015-10-01

    Nasal pain is a challenging diagnosis and very little has been reported in the neurological literature. The nose is a sophisticated structure regarding its innervation, which is supplied by the first and second divisions of the trigeminal nerve. Painful cranial neuropathies are an important group in the differential diagnosis, although they have been described only scarcely. Here, we report a case that can conform a non-traumatic external nasal nerve neuralgia. A 76-year-old woman was referred to our office due to pain in her left nose. She was suffering from daily excruciating attacks, which were strictly limited to the territory supplied by her left external nasal nerve (left ala nasi and apex nasi). She denied previous traumatisms and the ancillary tests did not yield any underlying pathology. An anesthetic blockade of her left external nasal nerve achieved a marked reduction of the number of episodes as well as their intensity. External nasal neuralgia seems a specific neuralgia causing nasal pain. Anesthetic blockades of the external nasal nerve may be a valid treatment for this condition. © 2015 American Headache Society.

  12. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    PubMed

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  13. Respiratory reflexes in response to nasal administration of halothane to anesthetized, spontaneously breathing dogs.

    PubMed

    Mutoh, T; Kanamaru, A; Tsubone, H; Nishimura, R; Sasaki, N

    2000-03-01

    To characterize and determine the sensory innervation of respiratory reflexes elicited by nasal administration of halothane to dogs. 10 healthy Beagles. Dogs underwent permanent tracheostomy and, 2 to 3 weeks later, were anesthetized with thiopental and alpha-chloralose administered IV. The nasal passages were functionally isolated so that halothane could be administered to the nasal passages while dogs were breathing 100% O2 via the tracheostomy. Respiratory reflexes in response to administration of halothane at concentrations of 1.25, 1.75, and 2.5 times the minimum alveolar concentration (MAC), and 5% (administered in 100% O2 at a flow rate of 5 L/min) were recorded. Reflexes in response to administration of 5% halothane were also recorded following transection of the infraorbital nerve, transection of the caudal nasal nerve, and nasal administration of lidocaine. Nasal administration of halothane induced an inhibition of breathing characterized by a dose-dependent increase in expiratory time and a resultant decrease in expired volume per unit time. Effects were noticeable immediately after the onset of halothane administration and lasted until its cessation. Reflex responses to halothane administration were attenuated by transection of the caudal nasal nerve and by nasal administration of lidocaine, but transection of the infraorbital nerve had no effect. Nasal administration of halothane at concentrations generally used for mask induction of anesthesia induces reflex inhibition of breathing. Afferent fibers in the caudal nasal nerve appear to play an important role in the reflex inhibition of breathing induced by halothane administration.

  14. Management of nasal septal perforation using silicone nasal septal button

    PubMed Central

    Mullace, M; Gorini, E; Sbrocca, M; Artesi, L; Mevio, N

    2006-01-01

    Summary Nasal septal perforation may present with various symptoms: epistaxis, crusting, secondary infection, whistling and nasal obstruction. Perforation may be treated by conservative pharmacological treatment or closed by surgical approach. A useful alternative is mechanical obturation, achieved inserting a prosthesis. The present report refers to a study on 15 patients (10 male, 5 female, mean age 38.5 years) treated by insertion of a one-piece or two-piece silicone septal button (Xomed). In the follow-up period, insertion of the nasal button reduced epistaxis, eliminated whistling during inspiration, and reduced nasal obstruction and crusting around the margin of the perforation. Contraindications are presence of acute infection with osteitis, chronic septal disease (Wegener), neoplasia and extremely large perforations. The latest buttons appear to be superior to the conventional type on account of plasticity and adaptability which offer greater conformity to the septum. This study also reveals that the new septal button is well tolerated by patients. PMID:18236638

  15. The influence of inspiratory muscle training combined with the Pilates method on lung function in elderly women: A randomized controlled trial.

    PubMed

    Alvarenga, Guilherme Medeiros de; Charkovski, Simone Arando; Santos, Larissa Kelin Dos; Silva, Mayara Alves Barbosa da; Tomaz, Guilherme Oliveira; Gamba, Humberto Remigio

    2018-01-01

    Aging is progressive, and its effects on the respiratory system include changes in the composition of the connective tissues of the lung that influence thoracic and lung compliance. The Powerbreathe® K5 is a device used for inspiratory muscle training with resistance adapted to the level of the inspiratory muscles to be trained. The Pilates method promotes muscle rebalancing exercises that emphasize the powerhouse. The aim of this study was to evaluate the influence of inspiratory muscle training combined with the Pilates method on lung function in elderly women. The participants were aged sixty years or older, were active women with no recent fractures, and were not gait device users. They were randomly divided into a Pilates with inspiratory training group (n=11), a Pilates group (n=11) and a control group (n=9). Spirometry, manovacuometry, a six-minute walk test, an abdominal curl-up test, and pulmonary variables were assessed before and after twenty intervention sessions. The intervention led to an increase in maximal inspiratory muscle strength and pressure and power pulmonary variables (p<0.0001), maximal expiratory muscle strength (p<0.0014), six-minute walk test performance (p<0.01), and abdominal curl-up test performance (p<0.00001). The control group showed no differences in the analyzed variables (p>0.05). The results of this study suggest inspiratory muscle training associated with the Pilates method provides an improvement in the lung function and physical conditioning of elderly patients.

  16. Complications of Nasal Bone Fractures.

    PubMed

    Hwang, Kun; Yeom, Seung Han; Hwang, Suk Hyun

    2017-05-01

    The aim of this study was to perform a systematic review of the treatment of nasal bone fractures. The search terms ("nasal bone fracture" AND complication) and ("nasal bone fracture" AND [anosmia OR olfaction OR olfactory nerve OR smell]) and (anosmia AND ["nasal preparation" OR "nasal antiseptics"]) were used to search PubMed and SCOPUS. Of the 500 titles, 40 full papers were reviewed. One paper was excluded, and 3 mined papers were added. Ultimately, 12 papers were analyzed. The overall deformity rate was 10.4% ± 4.8%. No significant differences were found between patients who underwent closed reduction (14.7% ± 7.3%) and those who underwent open reduction (9.4% ± 4.4%), between those who underwent local anesthesia (5.8% ± 4.5%), and those who underwent general anesthesia (8.8% ± 3.8%), or between those who received timely treatment (5.7%) and those whose treatment was delayed (9.0%). Septal deviation occurred in 10.0% of patients as a sequela of nasal bone fracture. The nasal obstruction rate was 10.5% ± 5.3%. Fewer patients of nasal obstruction occurred in the open reduction patients (6.9% ± 4.4%) than in the closed reduction patients (15.2%). One patient of epiphora and 1 patient of diplopia were reportedAmong the 77 patients with nasal bone fractures, 29 (37.7% ± 11.3%) complained of olfactory disturbances. No significant associations were found between the type of fracture and the presence of olfactory disturbances. It is recommended for providers to explain to patients that approximately one-tenth of nasal bone fractures exhibit deformity, septal deviation, or nasal obstruction after surgery. Surgeons should take considerable care to avoid the olfactory mucosa during reduction surgery.

  17. Validation of automated lobe segmentation on paired inspiratory-expiratory chest CT in 8-14 year-old children with cystic fibrosis.

    PubMed

    Konietzke, Philip; Weinheimer, Oliver; Wielpütz, Mark O; Savage, Dasha; Ziyeh, Tiglath; Tu, Christin; Newman, Beverly; Galbán, Craig J; Mall, Marcus A; Kauczor, Hans-Ulrich; Robinson, Terry E

    2018-01-01

    Densitometry on paired inspiratory and expiratory multidetector computed tomography (MDCT) for the quantification of air trapping is an important approach to assess functional changes in airways diseases such as cystic fibrosis (CF). For a regional analysis of functional deficits, an accurate lobe segmentation algorithm applicable to inspiratory and expiratory scans is beneficial. We developed a fully automated lobe segmentation algorithm, and subsequently validated automatically generated lobe masks (ALM) against manually corrected lobe masks (MLM). Paired inspiratory and expiratory CTs from 16 children with CF (mean age 11.1±2.4) acquired at 4 time-points (baseline, 3mon, 12mon, 24mon) with 2 kernels (B30f, B60f) were segmented, resulting in 256 ALM. After manual correction spatial overlap (Dice index) and mean differences in lung volume and air trapping were calculated for ALM vs. MLM. The mean overlap calculated with Dice index between ALM and MLM was 0.98±0.02 on inspiratory, and 0.86±0.07 on expiratory CT. If 6 lobes were segmented (lingula treated as separate lobe), the mean overlap was 0.97±0.02 on inspiratory, and 0.83±0.08 on expiratory CT. The mean differences in lobar volumes calculated in accordance with the approach of Bland and Altman were generally low, ranging on inspiratory CT from 5.7±52.23cm3 for the right upper lobe to 17.41±14.92cm3 for the right lower lobe. Higher differences were noted on expiratory CT. The mean differences for air trapping were even lower, ranging from 0±0.01 for the right upper lobe to 0.03±0.03 for the left lower lobe. Automatic lobe segmentation delivers excellent results for inspiratory and good results for expiratory CT. It may become an important component for lobe-based quantification of functional deficits in cystic fibrosis lung disease, reducing necessity for user-interaction in CT post-processing.

  18. Effects of nasal positive expiratory pressure on dynamic hyperinflation and 6-minute walk test in patients with COPD.

    PubMed

    Wibmer, Thomas; Rüdiger, Stefan; Heitner, Claudia; Kropf-Sanchen, Cornelia; Blanta, Ioanna; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-05-01

    Dynamic hyperinflation is an important target in the treatment of COPD. There is increasing evidence that positive expiratory pressure (PEP) could reduce dynamic hyperinflation during exercise. PEP application through a nasal mask and a flow resistance device might have the potential to be used during daily physical activities as an auxiliary strategy of ventilatory assistance. The aim of this study was to determine the effects of nasal PEP on lung volumes during physical exercise in patients with COPD. Twenty subjects (mean ± SD age 69.4 ± 6.4 years) with stable mild-to-severe COPD were randomized to undergo physical exercise with nasal PEP breathing, followed by physical exercise with habitual breathing, or vice versa. Physical exercise was induced by a standard 6-min walk test (6 MWT) protocol. PEP was applied by means of a silicone nasal mask loaded with a fixed-orifice flow resistor. Body plethysmography was performed immediately pre-exercise and post-exercise. Differences in mean pre- to post-exercise changes in total lung capacity (-0.63 ± 0.80 L, P = .002), functional residual capacity (-0.48 ± 0.86 L, P = .021), residual volume (-0.56 ± 0.75 L, P = .004), S(pO2) (-1.7 ± 3.4%, P = .041), and 6 MWT distance (-30.8 ± 30.0 m, P = .001) were statistically significant between the experimental and the control interventions. The use of flow-dependent expiratory pressure, applied with a nasal mask and a PEP device, might promote significant reduction of dynamic hyperinflation during walking exercise. Further studies are warranted addressing improvements in endurance performance under regular application of nasal PEP during physical activities.

  19. Effect of Deviated Nasal Septum Type on Nasal Mucociliary Clearance, Olfactory Function, Quality of Life, and Efficiency of Nasal Surgery.

    PubMed

    Berkiten, Güler; Kumral, Tolgar Lütfi; Saltürk, Ziya; Atar, Yavuz; Yildirim, Güven; Uyar, Yavuz; Aydoğdu, Imran; Arslanoğlu, Ahmet

    2016-07-01

    The aim of this study was to analyze the influence of deviated nasal septum (DNS) type on nasal mucociliary clearance, quality of life (QoL), olfactory function, and efficiency of nasal surgery (septoplasty with or without inferior turbinate reduction and partial middle turbinectomy). Fifty patients (20 females and 30 males) with septal deviation were included in the study and were divided into 6 groups according to deviation type after examination by nasal endoscopy and paranasal computed tomography. The saccharin clearance test to evaluate the nasal mucociliary clearance time, Connecticut Chemosensory Clinical Research Center smell test for olfactory function, and sinonasal outcome test-22 (SNOT-22) for patient satisfaction were applied preoperatively and postoperatively at the sixth week after surgery. Nasal mucociliary clearance, smell, and SNOT-22 scores were measured before surgery and at the sixth week following surgery. No significant difference was found in olfactory and SNOT-22 scores for any of the DNS types (both convex and concave sides) (P > 0.05). In addition, there was no difference in the saccharin clearance time (SCT) of the concave and convex sides (P > 0.05). According to the DNS type, the mean SCT of the convex sides showed no difference, but that of the concave sides showed a difference in types 3, 4, 5, and 6. These types had a prolonged SCT (P < 0.05). Olfactory scores revealed no difference postoperatively in types 5 and 6 but were decreased significantly in types 1 to 4 (P < 0.05). There was no significant difference in the healing of both the mucociliary clearance (MCC) and olfactory functions. SNOT-22 results showed a significant decrease in type 3. All DNS types disturb the QoL regarding nasal MCC and olfaction functions. MCC values, olfactory function, and QoL scores are similar among the DNS types. Both sides of the DNS types affect the MCC scores symmetrically. Septal surgery improves olfaction function and QoL at the

  20. Nasal glial heterotopia or congenital hemangioma? A case report.

    PubMed

    Lartizien, R; Durand, C; Blaise, S; Morand, B

    2017-10-01

    Nasal glial heterotopia (NGH) is a rare benign tumor of the median line. We describe the case of a child presenting a lateral nasal mass. The characteristics of the prenatal ultrasound and the postnatal clinical examination argued in favor of a congenital hemangioma (CH). The MRI performed at 6 weeks of life suggested glial heterotopia. This diagnosis was confirmed by the pathological analysis. Congenital hemangiomas and nasal glial heterotopies have similar clinical presentations. Prenatal ultrasound diagnosis between NGH and CH is difficult. Fetal MRI is not yet highly specific for these two lesions, but it can eliminate an intracerebral connection in cases of NGH. Postnatal exams are more specific. Flow on the Doppler exam is rapid for CH and slow for NGH. On MRI, these two lesions appear as a hypersignal on T2-weighted sequences, but less intense for NGH than for CH. Distinguishing between NGH and CH can be difficult. This does not have a direct incidence on treatment because it is surgical in both cases. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Measurement of inspiratory muscle performance with incremental threshold loading: a comparison of two techniques.

    PubMed Central

    Bardsley, P A; Bentley, S; Hall, H S; Singh, S J; Evans, D H; Morgan, M D

    1993-01-01

    BACKGROUND--Incremental threshold loading (ITL) is a test of inspiratory muscle performance which is usually performed by breathing through a weighted inspiratory plunger, the load on the inspiratory muscles being increased by externally adding weights to the intake valve. This is not a true threshold device and may be inaccurate. This method was compared with a true threshold device consisting of a solenoid valve which only opens to supply air at a predetermined negative mouth pressure. METHODS--Six naive, normal subjects (three men and three women) aged 22-24 years underwent three tests using each system. The inspiratory loads were increased every minute by equivalent amounts, -10 cm H2O with the solenoid valve and by 50 g with the weighted plunger, until the subjects could not inspire or sustain inspiration for a full minute. Six experienced subjects (four men and two women) aged 23-41 years were subsequently randomised to perform ITL with the solenoid valve, twice with the breathing pattern fixed and twice free. RESULTS--The solenoid valve generated a more accurate mouth pressure response and was less variable at higher loads than the weighted plunger. The work performed (expressed as the pressure-time product) was less with the solenoid valve but was more reproducible. ITL with the solenoid valve was not influenced by controlling the breathing pattern of the subjects. CONCLUSIONS--The solenoid valve has several features that make it superior to the weighted plunger as a device for ITL. It generates a more accurate mouth pressure response which is less variable at higher loads. Increases in load are smoother and quicker to introduce. ITL with the solenoid valve is not influenced by varying breathing patterns and does not require any external regulation. PMID:8511732

  2. Measurement of inspiratory muscle performance with incremental threshold loading: a comparison of two techniques.

    PubMed

    Bardsley, P A; Bentley, S; Hall, H S; Singh, S J; Evans, D H; Morgan, M D

    1993-04-01

    Incremental threshold loading (ITL) is a test of inspiratory muscle performance which is usually performed by breathing through a weighted inspiratory plunger, the load on the inspiratory muscles being increased by externally adding weights to the intake valve. This is not a true threshold device and may be inaccurate. This method was compared with a true threshold device consisting of a solenoid valve which only opens to supply air at a predetermined negative mouth pressure. Six naive, normal subjects (three men and three women) aged 22-24 years underwent three tests using each system. The inspiratory loads were increased every minute by equivalent amounts, -10 cm H2O with the solenoid valve and by 50 g with the weighted plunger, until the subjects could not inspire or sustain inspiration for a full minute. Six experienced subjects (four men and two women) aged 23-41 years were subsequently randomised to perform ITL with the solenoid valve, twice with the breathing pattern fixed and twice free. The solenoid valve generated a more accurate mouth pressure response and was less variable at higher loads than the weighted plunger. The work performed (expressed as the pressure-time product) was less with the solenoid valve but was more reproducible. ITL with the solenoid valve was not influenced by controlling the breathing pattern of the subjects. The solenoid valve has several features that make it superior to the weighted plunger as a device for ITL. It generates a more accurate mouth pressure response which is less variable at higher loads. Increases in load are smoother and quicker to introduce. ITL with the solenoid valve is not influenced by varying breathing patterns and does not require any external regulation.

  3. Effects of lung protective mechanical ventilation associated with permissive respiratory acidosis on regional extra-pulmonary blood flow in experimental ARDS.

    PubMed

    Hering, Rudolf; Kreyer, Stefan; Putensen, Christian

    2017-10-27

    Lung protective mechanical ventilation with limited peak inspiratory pressure has been shown to affect cardiac output in patients with ARDS. However, little is known about the impact of lung protective mechanical ventilation on regional perfusion, especially when associated with moderate permissive respiratory acidosis. We hypothesized that lung protective mechanical ventilation with limited peak inspiratory pressure and moderate respiratory acidosis results in an increased cardiac output but unequal distribution of blood flow to the different organs of pigs with oleic-acid induced ARDS. Twelve pigs were enrolled, 3 died during instrumentation and induction of lung injury. Thus, 9 animals received pressure controlled mechanical ventilation with a PEEP of 5 cmH 2 O and limited peak inspiratory pressure (17 ± 4 cmH 2 O) versus increased peak inspiratory pressure (23 ± 6 cmH 2 O) in a crossover-randomized design and were analyzed. The sequence of limited versus increased peak inspiratory pressure was randomized using sealed envelopes. Systemic and regional hemodynamics were determined by double indicator dilution technique and colored microspheres, respectively. The paired student t-test and the Wilcoxon test were used to compare normally and not normally distributed data, respectively. Mechanical ventilation with limited inspiratory pressure resulted in moderate hypercapnia and respiratory acidosis (PaCO 2 71 ± 12 vs. 46 ± 9 mmHg, and pH 7.27 ± 0.05 vs. 7.38 ± 0.04, p < 0.001, respectively), increased cardiac output (140 ± 32 vs. 110 ± 22 ml/min/kg, p<0.05) and regional blood flow in the myocardium, brain and spinal cord, adrenal and thyroid glands, the mucosal layers of the esophagus and jejunum, the muscularis layers of the esophagus and duodenum, and the gall and urinary bladders. Perfusion of kidneys, pancreas, spleen, hepatic arterial bed, and the mucosal and muscularis blood flow to the other evaluated intestinal regions remained unchanged. In this

  4. Cosmetic and Functional Nasal Deformities

    MedlinePlus

    ... nasal complaints. Nasal deformity can be categorized as “cosmetic” or “functional.” Cosmetic deformity of the nose results in a less ... taste , nose bleeds and/or recurrent sinusitis . A cosmetic or functional nasal deformity may occur secondary to ...

  5. Cosmetic rostral nasal reconstruction after nasal planum and premaxilla resection: technique and results in two dogs.

    PubMed

    Gallegos, Javier; Schmiedt, Chad W; McAnulty, Jonathan F

    2007-10-01

    To describe a novel reconstructive technique after nasal planum and premaxilla resection. Case report. Dogs (n=2) with squamous cell carcinoma (SCC) of the nasal planum. A 9-year-old neutered female Labrador retriever (dog 1) and an 11-year-old neutered male Golden retriever (dog 2) had resection of the nasal planum and premaxilla for treatment of locally invasive SCC. Reconstruction of a nasal planum facsimile was based on use of the nonhaired pigmented margins of bilateral labial mucocutaneous rotation-advancement flaps. Reconstruction of the premaxilla by construction of a nasal planum facsimile resulted in uncomplicated wound healing and improved cosmesis. There was no tumor recurrence at 1290 (dog 1) and 210 (dog 2) days after surgery. Reconstruction of a nasal planum facsimile was successfully performed without complications in 2 dogs with high owner satisfaction with cosmetic appearance. This technique represents a significant advancement in surgical cosmetic outcome, may potentially reduce postoperative complications, and should be considered for dogs requiring nasal reconstruction after nasal planum resection with premaxillectomy.

  6. Smart Polymers in Nasal Drug Delivery

    PubMed Central

    Chonkar, Ankita; Nayak, Usha; Udupa, N.

    2015-01-01

    Nasal drug delivery has now been recognized as a promising route for drug delivery due to its capability of transporting a drug to systemic circulation and central nervous system. Though nasal mucosa offers improved bioavailability and quick onset of action of the drug, main disadvantage associated with nasal drug delivery is mucocilliary clearance due to which drug particles get cleared from the nose before complete absorption through nasal mucosa. Therefore, mucoadhesive polymeric approach can be successfully used to enhance the retention of the drug on nasal mucosal surface. Here, some of the aspects of the stimuli responsive polymers have been discussed which possess liquid state at the room temperature and in response to nasal temperature, pH and ions present in mucous, can undergo in situ gelation in nasal cavity. In this review, several temperature responsive, pH responsive and ion responsive polymers used in nasal delivery, their gelling mechanisms have been discussed. Smart polymers not only able to enhance the retention of the drug in nasal cavity but also provide controlled release, ease of administration, enhanced permeation of the drug and protection of the drug from mucosal enzymes. Thus smart polymeric approach can be effectively used for nasal delivery of peptide drugs, central nervous system dugs and hormones. PMID:26664051

  7. The influence of inspiratory muscle training combined with the Pilates method on lung function in elderly women: A randomized controlled trial

    PubMed Central

    de Alvarenga, Guilherme Medeiros; Charkovski, Simone Arando; dos Santos, Larissa Kelin; da Silva, Mayara Alves Barbosa; Tomaz, Guilherme Oliveira; Gamba, Humberto Remigio

    2018-01-01

    OBJECTIVE: Aging is progressive, and its effects on the respiratory system include changes in the composition of the connective tissues of the lung that influence thoracic and lung compliance. The Powerbreathe® K5 is a device used for inspiratory muscle training with resistance adapted to the level of the inspiratory muscles to be trained. The Pilates method promotes muscle rebalancing exercises that emphasize the powerhouse. The aim of this study was to evaluate the influence of inspiratory muscle training combined with the Pilates method on lung function in elderly women. METHODS: The participants were aged sixty years or older, were active women with no recent fractures, and were not gait device users. They were randomly divided into a Pilates with inspiratory training group (n=11), a Pilates group (n=11) and a control group (n=9). Spirometry, manovacuometry, a six-minute walk test, an abdominal curl-up test, and pulmonary variables were assessed before and after twenty intervention sessions. RESULTS: The intervention led to an increase in maximal inspiratory muscle strength and pressure and power pulmonary variables (p<0.0001), maximal expiratory muscle strength (p<0.0014), six-minute walk test performance (p<0.01), and abdominal curl-up test performance (p<0.00001). The control group showed no differences in the analyzed variables (p>0.05). CONCLUSION: The results of this study suggest inspiratory muscle training associated with the Pilates method provides an improvement in the lung function and physical conditioning of elderly patients. PMID:29924184

  8. Risk factors for nasal malignancies in German men: the South-German Nasal cancer study.

    PubMed

    Greiser, Eberhard M; Greiser, Karin Halina; Ahrens, Wolfgang; Hagen, Rudolf; Lazszig, Roland; Maier, Heinz; Schick, Bernhard; Zenner, Hans Peter

    2012-11-06

    There are few studies of the effects of nasal snuff and environmental factors on the risk of nasal cancer. This study aimed to investigate the impact of using nasal snuff and of other risk factors on the risk of nasal cancer in German men. A population-based case-control study was conducted in the German Federal States of Bavaria and Baden-Württemberg. Tumor registries and ear, nose and throat departments provided access to patients born in 1926 or later. Telephone interviews were conducted with 427 cases (mean age 62.1 years) and 2.401 population-based controls (mean age 60.8 years). Ever-use of nasal snuff was associated with an odds ratio (OR) for nasal cancer of 1.45 (95% confidence interval [CI] 0.88-2.38) in the total study population, whereas OR in smokers was 2.01 (95% CI 1.00-4.02) and in never smokers was 1.10 (95% CI 0.43-2.80). The OR in ever-smokers vs. never-smokers was 1.60 (95% CI 1.24-2.07), with an OR of 1.06 (95% CI 1.05-1.07) per pack-year smoked, and the risk was significantly decreased after quitting smoking. Exposure to hardwood dust for at least 1 year resulted in an OR of 2.33 (95% CI 1.40-3.91) in the total population, which was further increased in never-smokers (OR 4.89, 95% CI 1.92-12.49) in analyses stratified by smoking status. The OR for nasal cancer after exposure to organic solvents for at least 1 year was 1.53 (1.17-2.01). Ever-use of nasal sprays/nasal lavage for at least 1 month rendered an OR of 1.59 (1.04-2.44). The OR after use of insecticides in homes was 1.48 (95% CI 1.04-2.11). Smoking and exposure to hardwood dust were confirmed as risk factors for nasal carcinoma. There is evidence that exposure to organic solvents, and in-house use of insecticides could represent novel risk factors. Exposure to asbestos and use of nasal snuff were risk factors in smokers only.

  9. Nasal obstruction and human communication.

    PubMed

    Malinoff, R; Moreno, C

    1989-04-01

    Nasal obstruction may cause a variety of communication disorders, particularly in children. The effects of nasal obstruction on hearing, speech, language, and voice are examined. Methods for assessing the effects of nasal obstruction are delineated, and recommendations for therapeutic interventions are described.

  10. When Breathing Interferes with Cognition: Experimental Inspiratory Loading Alters Timed Up-and-Go Test in Normal Humans.

    PubMed

    Nierat, Marie-Cécile; Demiri, Suela; Dupuis-Lozeron, Elise; Allali, Gilles; Morélot-Panzini, Capucine; Similowski, Thomas; Adler, Dan

    2016-01-01

    Human breathing stems from automatic brainstem neural processes. It can also be operated by cortico-subcortical networks, especially when breathing becomes uncomfortable because of external or internal inspiratory loads. How the "irruption of breathing into consciousness" interacts with cognition remains unclear, but a case report in a patient with defective automatic breathing (Ondine's curse syndrome) has shown that there was a cognitive cost of breathing when the respiratory cortical networks were engaged. In a pilot study of putative breathing-cognition interactions, the present study relied on a randomized design to test the hypothesis that experimentally loaded breathing in 28 young healthy subjects would have a negative impact on cognition as tested by "timed up-and-go" test (TUG) and its imagery version (iTUG). Progressive inspiratory threshold loading resulted in slower TUG and iTUG performance. Participants consistently imagined themselves faster than they actually were. However, progressive inspiratory loading slowed iTUG more than TUG, a finding that is unexpected with regard to the known effects of dual tasking on TUG and iTUG (slower TUG but stable iTUG). Insofar as the cortical networks engaged in response to inspiratory loading are also activated during complex locomotor tasks requiring cognitive inputs, we infer that competition for cortical resources may account for the breathing-cognition interference that is evidenced here.

  11. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external nasal...

  12. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external nasal...

  13. The relationship between partial upper-airway obstruction and inter-breath transition period during sleep.

    PubMed

    Mann, Dwayne L; Edwards, Bradley A; Joosten, Simon A; Hamilton, Garun S; Landry, Shane; Sands, Scott A; Wilson, Stephen J; Terrill, Philip I

    2017-10-01

    Short pauses or "transition-periods" at the end of expiration and prior to subsequent inspiration are commonly observed during sleep in humans. However, the role of transition periods in regulating ventilation during physiological challenges such as partial airway obstruction (PAO) has not been investigated. Twenty-nine obstructive sleep apnea patients and eight controls underwent overnight polysomnography with an epiglottic catheter. Sustained-PAO segments (increased epiglottic pressure over ≥5 breaths without increased peak inspiratory flow) and unobstructed reference segments were manually scored during apnea-free non-REM sleep. Nasal pressure data was computationally segmented into inspiratory (T I , shortest period achieving 95% inspiratory volume), expiratory (T E , shortest period achieving 95% expiratory volume), and inter-breath transition period (T Trans , period between T E and subsequent T I ). Compared with reference segments, sustained-PAO segments had a mean relative reduction in T Trans (-24.7±17.6%, P<0.001), elevated T I (11.8±10.5%, P<0.001), and a small reduction in T E (-3.9±8.0, P≤0.05). Compensatory increases in inspiratory period during PAO are primarily explained by reduced transition period and not by reduced expiratory period. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. CD-sens can be a reliable and easy-to-use complement in the diagnosis of allergic rhinitis.

    PubMed

    Nopp, A; Cardell, L O; Johansson, S G O

    2013-01-01

    A reproducible standard for a graded allergen response in allergic rhinitis is lacking. The aim was to evaluate basophil allergen threshold sensitivity, CD-sens, as a diagnostic complement to nasal allergen challenge. Twenty-six patients with a history of allergic rhinitis due to grass pollen were intranasally challenged and nasal symptom score and peak nasal inspiratory flow (PNIF) changes were determined after 15 min. A 20% decrease in PNIF or a symptom score ≥2 were considered a positive test. A blood sample for CD-sens was drawn before each challenge. Eighteen patients were tested twice. CD-sens agreed with the positive or negative nasal symptom score in 22/26 and PNIF in 24/26 patients. After the second challenge, 14/18 patients had the same symptom, 17/18 the same PNIF, while all had identical CD-sens classification. CD-sens appears to be a reproducible test for diagnosis of allergic rhinitis with great advantages also for follow-up of disease development and treatment effects. Copyright © 2012 S. Karger AG, Basel.

  15. New CFD tools to evaluate nasal airflow.

    PubMed

    Burgos, M A; Sanmiguel-Rojas, E; Del Pino, C; Sevilla-García, M A; Esteban-Ortega, F

    2017-08-01

    Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. As currently CFD is not a usual tool for rhinologists, a group of engineers in collaboration with experts in Rhinology have developed a very intuitive CFD software. The program MECOMLAND ® only required snapshots from the patient's cross-sectional (tomographic) images, being the output those results originated by CFD, such as airflow distributions, velocity profiles, pressure, temperature, or wall shear stress. This is useful complementary information to cover diagnosis, prognosis, or follow-up of nasal pathologies based on quantitative magnitudes linked to airflow. In addition, the user-friendly environment NOSELAND ® helps the medical assessment significantly in the post-processing phase with dynamic reports using a 3D endoscopic view. Specialists in Rhinology have been asked for a more intuitive, simple, powerful CFD software to offer more quality and precision in their work to evaluate the nasal airflow. We present MECOMLAND ® and NOSELAND ® which have all the expected characteristics to fulfil this demand and offer a proper assessment with the maximum of quality plus safety for the patient. These programs represent a non-invasive, low-cost (as the CT scan is already performed in every patient) alternative for the functional study of the difficult rhinologic case. To validate the software, we studied two groups of patients from the Ear Nose Throat clinic, a first group with normal noses and a second group presenting septal deviations. Wall shear stresses are lower in the cases of normal noses in comparison with those for septal deviation. Besides, velocity field distributions, pressure drop between nasopharynx and the ambient, and flow rates in each nostril were different among the nasal cavities in the two groups. These software modules open up a promising future to simulate the nasal airflow behaviour in virtual surgery intervention scenarios under different pressure or

  16. Refining the Use of Nasal High-Flow Therapy as Primary Respiratory Support for Preterm Infants.

    PubMed

    Manley, Brett J; Roberts, Calum T; Frøisland, Dag H; Doyle, Lex W; Davis, Peter G; Owen, Louise S

    2018-05-01

    To identify clinical and demographic variables that predict nasal high-flow (nHF) treatment failure when used as a primary respiratory support for preterm infants. This secondary analysis used data from a multicenter, randomized, controlled trial comparing nHF with continuous positive airway pressure as primary respiratory support in preterm infants 28-36 completed weeks of gestation. Treatment success or failure with nHF was determined using treatment failure criteria within the first 72 hours after randomization. Infants in whom nHF treatment failed received continuous positive airway pressure, and were then intubated if failure criteria were again met. There were 278 preterm infants included, with a mean gestational age (GA) of 32.0 ± 2.1 weeks and a birth weight of 1737 ± 580 g; of these, nHF treatment failed in 71 infants (25.5%). Treatment failure was moderately predicted by a lower GA and higher prerandomization fraction of inspired oxygen (FiO 2 ): area under a receiver operating characteristic curve of 0.76 (95% CI, 0.70-0.83). Nasal HF treatment success was more likely in infants born at ≥30 weeks GA and with prerandomization FiO 2 <0.30. In preterm infants ≥28 weeks' GA enrolled in a randomized, controlled trial, lower GA and higher FiO 2 before randomization predicted early nHF treatment failure. Infants were more likely to be successfully treated with nHF from soon after birth if they were born at ≥30 weeks GA and had a prerandomization FiO 2 <0.30. However, even in this select population, continuous positive airway pressure remains superior to nHF as early respiratory support in preventing treatment failure. Australian New Zealand Clinical Trials Registry: ACTRN12613000303741. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. [Nasal septal abscess].

    PubMed

    Barril, María F; Ferolla, Fausto M; José, Pablo; Echave, Cecilia; Tomezzoli, Silvana; Fiorini, Sandra; López, Eduardo Luis

    2008-12-01

    A nasal septal abscess (NA) is defined as a collection of pus between the cartilage or bony septum and its normally applied mucoperichondrium or mucoperiostium. It is an uncommon disease which should be suspected in a patient with acute onset of nasal obstruction and recent history of nasal trauma, periodontal infection or an inflammatory process of the rhinosinusal region. We report a case of an 8-year-old boy with bilateral NA caused by community-acquired methicillin-resistant Staphylococcus aureus(MR-CO) in order to emphasize the importance of prompt diagnosis and adequate treatment to prevent the potentially dangerous spread of infection and the development of severe functional and cosmetic sequelae.

  18. Cycle ergometer and inspiratory muscle training offer modest benefit compared with cycle ergometer alone: a comprehensive assessment in stable COPD patients.

    PubMed

    Wang, Kai; Zeng, Guang-Qiao; Li, Rui; Luo, Yu-Wen; Wang, Mei; Hu, Yu-He; Xu, Wen-Hui; Zhou, Lu-Qian; Chen, Rong-Chang; Chen, Xin

    2017-01-01

    Cycle ergometer training (CET) has been shown to improve exercise performance of the quadriceps muscles in patients with COPD, and inspiratory muscle training (IMT) may improve the pressure-generating capacity of the inspiratory muscles. However, the effects of combined CET and IMT remain unclear and there is a lack of comprehensive assessment. Eighty-one patients with COPD were randomly allocated to three groups: 28 received 8 weeks of CET + IMT (combined training group), 27 received 8 weeks of CET alone (CET group), and 26 only received 8 weeks of free walking (control group). Comprehensive assessment including respiratory muscle strength, exercise capacity, pulmonary function, dyspnea, quality of life, emotional status, nutritional status, and body mass index, airflow obstruction, and exercise capacity index were measured before and after the pulmonary rehabilitation program. Respiratory muscle strength, exercise capacity, inspiratory capacity, dyspnea, quality of life, depression and anxiety, and nutritional status were all improved in the combined training and CET groups when compared with that in the control group ( P <0.05) after pulmonary rehabilitation program. Inspiratory muscle strength increased significantly in the combined training group when compared with that in the CET group (ΔPI max [maximal inspiratory pressure] 5.20±0.89 cmH 2 O vs 1.32±0.91 cmH 2 O; P <0.05). However, there were no significant differences in the other indices between the two groups ( P >0.05). Patients with weakened respiratory muscles in the combined training group derived no greater benefit than those without respiratory muscle weakness ( P >0.05). There were no significant differences in these indices between the patients with malnutrition and normal nutrition after pulmonary rehabilitation program ( P >0.05). Combined training is more effective than CET alone for increasing inspiratory muscle strength. IMT may not be useful when combined with CET in patients with

  19. Effects of inspiratory muscle training on balance ability and abdominal muscle thickness in chronic stroke patients

    PubMed Central

    Oh, Dongha; Kim, Gayeong; Lee, Wanhee; Shin, Mary Myong Sook

    2016-01-01

    [Purpose] This study evaluated the effects of inspiratory muscle training on pulmonary function, deep abdominal muscle thickness, and balance ability in stroke patients. [Subjects] Twenty-three stroke patients were randomly allocated to an experimental (n = 11) or control group (n = 12). [Methods] The experimental group received inspiratory muscle training-based abdominal muscle strengthening with conventional physical therapy; the control group received standard abdominal muscle strengthening with conventional physical therapy. Treatment was conducted 20 minutes per day, 3 times per week for 6 weeks. Pulmonary function testing was performed using an electronic spirometer. Deep abdominal muscle thickness was measured by ultrasonography. Balance was measured using the Berg balance scale. [Results] Forced vital capacity, forced expiratory volume in 1 second, deep abdominal muscle thickness, and Berg balance scale scores were significantly improved in the experimental group than in the control group. [Conclusion] Abdominal muscle strengthening accompanied by inspiratory muscle training is recommended to improve pulmonary function in stroke patients, and may also be used as a practical adjunct to conventional physical therapy. PMID:26957739

  20. Nasal Glial Heterotopia with Cleft Palate.

    PubMed

    Chandna, Sudhir; Mehta, Milind A; Kulkarni, Abhishek Kishore

    2018-01-01

    Congenital midline nasal masses are rare anomalies of which nasal glial heterotopia represents an even rarer subset. We report a case of a 25-day-old male child with nasal glial heterotopia along with cleft palate suggesting embryonic fusion anomaly which was treated with excision and primary closure for nasal mass followed by palatal repair at later date.

  1. [Hemangiopericytoma in nasal cavity: a case report].

    PubMed

    Hu, Honghai; Shi, Qifeng; Chen, Jidong

    2015-05-01

    We report a case of a 46 year old female patient with nasal hemangiopericytoma. She complained of left nasal congestion, pus snot for 10 years, sometimes with left nasal bleeding. Physical examination: in the left nasal tract saw red soft neoplasm, roughness surface, easy bleeding when touched. Sinus CT shows: bilateral maxillary sinus, ethmoid sinus, sphenoid sinus and the left posterior nasal cavity lesions, considering inflammation with the formation of polyps, tumor not excluded. The left nasal cavity neoplasm biopsy shows: hemangioma of left nasal cavity. After admission in general anesthesia, we do transnasal endoscopic sinus openning operation and the left nasal cavity neoplasm resection. Postoperative pathological examination shows: the left nasal cavity hemangiopericytoma. Immunohistochemical showed: Vimentin(+), Smooth muscle actin(+), Desmin(-), endothelial cells CD31(-) and CD34(-). No postoperative radiotherapy or chemotherapy, no tumor recurrence. After one year of follow-up, the contact was lost.

  2. Objective measurements for grading the nasal esthetics on Basal view in individuals with secondary cleft nasal deformity.

    PubMed

    He, Xing; Li, Hua; Shao, Yan; Shi, Bing

    2015-01-01

    The purpose of this study is to ascertain objective nasal measurements from the basal view that are predictive of nasal esthetics in individuals with secondary cleft nasal deformity. Thirty-three patients who had undergone unilateral cleft lip repair were retrospectively reviewed in this study. The degree of nasal deformity was subjectively ranked by seven surgeons using standardized basal-view measurements. Nine physical objective parameters including angles and ratios were measured. Correlations and regressions between these objective and subjective measurements were then analyzed. There was high concordance in subjective measurements by different surgeons (Kendall's harmonious coefficient = W = .825, P = .006). The strongest predictive factors for nasal aesthetics were the ratio of length of nasal alar (r = .370, P = .034) and the degree of deviation of the columnar axis (r = .451, P = .008). The columellar angle had a more powerful effect in rating nasal esthetics. There was reliable concordance in subjective ranking of nasal esthetics by surgeons. Measurement of the columnar angle may serve as an independent, objective predictor of esthetics of the nose.

  3. Nasal mucosal gene expression in patients with allergic rhinitis with and without nasal polyps.

    PubMed

    Fritz, Stephen B; Terrell, Jeffrey E; Conner, Edward R; Kukowska-Latallo, Jolanta F; Baker, James R

    2003-12-01

    Nasal polyps are a common problem that is difficult to diagnose and treat, in part because the cause of nasal polyposis is unknown. Although information on the pathogenesis of polyposis is lacking, there are reports suggesting that a genetic predisposition underlies this disorder. We sought to better understand the basis of nasal polyposis associated with allergic rhinitis. We hypothesize that the expression of unique genes is associated with the nasal polyposis phenotype. We examined 12000 human genes transcribed in the nasal mucosa of patients with allergic rhinitis with and without nasal polyps. Biopsy specimens of the mucosa of patients with and without polyps were obtained after the patients refrained from the use of topical or systemic steroid therapy for 2 weeks. Thirty-four genes were differentially expressed between the patient groups, including those for inflammatory molecules and putative growth factors. The greatest differential expression identified by the array analysis was for a group of genes associated with neoplasia, including mammaglobin, a gene transcribed 12-fold higher in patients with polyps compared with control patients with rhinitis alone. Quantitative RT-PCR confirmed this differential expression and documented that the number of mammaglobin mRNA copies is actually 64-fold greater in tissues of patients with polyps versus control patients. The specificity of mammaglobin protein expression was evaluated by means of immunohistochemistry, which showed specific staining in nasal polyp mucosal goblet cells only in patients with polyps. These data suggest that nasal polyposis involves deregulated cell growth, using gene activation in some ways similar to a neoplasm. In addition, mammaglobin, a gene of unknown function associated with breast neoplasia, might be related to polyp growth.

  4. The value and safety of specific nasal provocation in the diagnosis of allergic rhinitis in mild persistent asthma under inhaled steroid therapy.

    PubMed

    Tuskan, Tansu Cengiz; Gemicioglu, Bilun; Ikitimur, Hande; Yilmaz, Nail; Tuskan, Kemal; Oz, Ferhan; Can, Gunay

    2010-01-01

    Although specific nasal provocation is an objective diagnostic test for allergic rhinitis, it can also increase the lower airway responsiveness in asthmatic patients. Our goal was to determine the value and safety of specific nasal provocation test for the diagnosis of allergic rhinitis in mild persistent asthmatic patients under low-dose inhaled steroid therapy. The study was performed on 32 mild persistent, stable, mite-sensitive allergic asthmatics (group 1), 9 mild persistent nonallergic asthmatics (group 2) and 9 healthy non-smokers (group 3). Nasal symptoms were noted, paranasal sinus computerized tomography (PNCT) and rhinoscopic evaluations were performed. Cases with pathologic-anatomic changes in PNCT and rhinoscopy were excluded. Symptom scoring, flow-volume, peak expiratory flow (PEF), serum and nasal lavage eosinophil cationic protein (ECP) and nasal lavage eosinophil counts were performed before mite specific nasal provocation test and at the 0th, 4th and 24th hours following the test. No adverse effects were observed in all diagnostic procedures. Total diagnostic value of nasal symptoms were found to be at 92%, while being 70% for rhinoscopy and 88% for specific nasal provocation test respectively in the diagnosis of allergic rhinitis in group 1. Statistically significant differences were found between basal nasal lavage eosinophil values (p < 0.001) and ECP levels (p < 0.05) when group 1 was compared with both group 2 and group 3. In the remaining measured values between three groups, no statistically significant differences were found. Specific nasal provocation test is a safe method for mild house dust mite allergic asthma cases under low-dose inhaled steroid therapy, but history of rhinitis might be sufficient for the diagnosis of allergic rhinitis.

  5. Health risks associated with inhaled nasal toxicants.

    PubMed

    Feron, V J; Arts, J H; Kuper, C F; Slootweg, P J; Woutersen, R A

    2001-05-01

    Health risks of inhaled nasal toxicants were reviewed with emphasis on chemically induced nasal lesions in humans, sensory irritation, olfactory and trigeminal nerve toxicity, nasal immunopathology and carcinogenesis, nasal responses to chemical mixtures, in vitro models, and nasal dosimetry- and metabolism-based extrapolation of nasal data in animals to humans. Conspicuous findings in humans are the effects of outdoor air pollution on the nasal mucosa, and tobacco smoking as a risk factor for sinonasal squamous cell carcinoma. Objective methods in humans to discriminate between sensory irritation and olfactory stimulation and between adaptation and habituation have been introduced successfully, providing more relevant information than sensory irritation studies in animals. Against the background of chemoperception as a dominant window of the brain on the outside world, nasal neurotoxicology is rapidly developing, focusing on olfactory and trigeminal nerve toxicity. Better insight in the processes underlying neurogenic inflammation may increase our knowledge of the causes of the various chemical sensitivity syndromes. Nasal immunotoxicology is extremely complex, which is mainly due to the pivotal role of nasal lymphoid tissue in the defense of the middle ear, eye, and oral cavity against antigenic substances, and the important function of the nasal passages in brain drainage in rats. The crucial role of tissue damage and reactive epithelial hyperproliferation in nasal carcinogenesis has become overwhelmingly clear as demonstrated by the recently developed biologically based model for predicting formaldehyde nasal cancer risk in humans. The evidence of carcinogenicity of inhaled complex mixtures in experimental animals is very limited, while there is ample evidence that occupational exposure to mixtures such as wood, leather, or textile dust or chromium- and nickel-containing materials is associated with increased risk of nasal cancer. It is remarkable that these

  6. Nasal packing and stenting

    PubMed Central

    Weber, Rainer K.

    2011-01-01

    Nasal packs are indispensable in ENT practice. This study reviews current indications, effectiveness and risks of nasal packs and stents. In endoscopic surgery, nasal packs should always have smooth surfaces to minimize mucosal damage, improve wound healing and increase patient comfort. Functional endoscopic endonasal sinus surgery allows the use of modern nasal packs, since pressure is no longer required. So called hemostatic/resorbable materials are a first step in this direction. However, they may lead to adhesions and foreign body reactions in mucosal membranes. Simple occlusion is an effective method for creating a moist milieu for improved wound healing and avoiding dryness. Stenting of the frontal sinus is recommended if surgery fails to produce a wide, physiologically shaped drainage path that is sufficiently covered by intact tissue. PMID:22073095

  7. Appraisal of transverse nasal groove: a study.

    PubMed

    Sathyanarayana, Belagola D; Basavaraj, Halevoor B; Nischal, Kuchangi C; Swaroop, Mukunda R; Umashankar, Puttagangu N; Agrawal, Dhruv P; Swamy, Suchetha S; Okram, Sarda

    2012-01-01

    Transverse nasal groove is a condition of cosmetic concern which awaits due recognition and has been widely described as a shallow groove that extends transversely over the dorsum of nose. However, we observed variations in the clinical presentations of this entity, hitherto undescribed in literature. We conducted a clinicoepidemiological study of transverse nasal lesions in patients attending our outpatient department. We conducted a prospective observational study. We screened all patients attending our out-patient department for presence of transverse nasal lesions, signs of any dermatosis and associated other skin conditions. One hundred patients were recruited in the study. Females (80%) predominated over males. Most patients were of 15-45 years age group (70%). Majority of the transverse nasal lesions were classical transverse nasal groove (39%) and others included transverse nasal line (28%), strip (28%), ridge (4%) and loop (1%). Seborrhoeic diathesis was the most common condition associated with transverse nasal lesion. Occurrence of transverse nasal line, strip, ridge and loop, in addition to classical transverse nasal groove implies that latter is actually a subset of transverse nasal lesions. Common association of this entity with seborrheic dermatitis, seborrhea and dandruff raises a possibility of whether transverse nasal lesion is a manifestation of seborrheic diathesis.

  8. Nasal budesonide offers superior symptom relief in perennial allergic rhinitis in comparison to nasal azelastine.

    PubMed

    Stern, M A; Wade, A G; Ridout, S M; Cambell, L M

    1998-10-01

    Allergic rhinitis is usually treated with oral antihistamines or nasal steroids. Topically active nasal antihistamine is a new treatment modality for allergic rhinitis. The efficacy in comparison to well established topical treatment alternatives is not fully known. To compare the efficacy of intranasally administered azelastine to budesonide, at their respectively recommended dosage, on the symptoms of perennial rhinitis patients. A placebo-controlled, randomized, parallel group study was conducted to compare the efficacy and tolerability of intranasal budesonide aqueous suspension (256 microg once daily) with azelastine hydrochloride nasal spray (280 microg twice daily (560 microg/day)) and with placebo in the treatment of perennial allergic rhinitis. The 195 patients (with at least a 2-year history of perennial allergic rhinitis) recorded individual nasal symptom scores, the degree of symptom control achieved and any adverse events experienced over a 2-week baseline period and a 6-week treatment period. Following treatment, the reductions in mean combined and individual nasal symptom scores from baseline values were significantly greater in the budesonide group compared with the placebo group (P < .0001 for all variables except runny nose P = .01). In patients treated with budesonide, there were also significantly larger reductions from baseline values in combined nasal symptom scores (P < .01) and in scores for all individual nasal symptoms (P < or = .05) compared with those treated with azelastine. The reductions from baseline in both combined and individual nasal symptom scores did not differ between azelastine and placebo. The study medications were well tolerated, producing no unexpected or serious treatment-related adverse events. A once-daily dose of 256 microg of intranasal budesonide aqueous suspension is significantly more effective at relieving the symptoms of perennial allergic rhinitis compared with a twice daily dose of 280 microg of azelastine

  9. The effect of high flow nasal cannula oxygen therapy on middle ear pressure.

    PubMed

    Piastro, Kristina; Chaskes, Mark; Agarwal, Jay; Parnes, Steven

    2016-01-01

    To investigate the effect of high flow nasal cannula oxygen therapy (HFOT) on middle ear pressure. Ten patients (eight males and two females) with oxygen desaturations requiring HFOT were recruited with 19 ears available for our study. The study group was aged 29-90years (mean 65.3±16.5). All patients underwent a review of medical history, questioned about subjective hearing loss and underwent a standard otologic exam, with middle ear pressures measured with a GSI TympStar tympanometer. The middle ear peak pressures in our study group ranged from 25 to -200daPa (mean -13.7±56.3daPa). Volume of HFOT was delivered at 20-40L (mean 30.5±9L) and fraction of inspired oxygen required was 30-70% (mean 58±13%). There was a positive correlation between liters of oxygen delivery and middle ear pressure with a Pearson coefficient (R) of 0.436, although lacking statistical significance (p=0.06). Previous studies have shown that HFOT delivered in the range of 35-40L/min produces pharyngeal pressures at or above 5cm H2O. Since pharyngeal pressures of 5cm H2O produced via CPAP have shown to produce middle ear pressures above 40daPa, we expected HFOT to result in similar middle ear pressures of 35-40L/min. However, although our results show an increase in middle ear pressures with flow volume, HFOT did not produce significant increases in middle ear pressures. This may make HFOT an appropriate option of oxygen delivery to patients who require otologic procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Are glucose levels, glucose variability and autonomic control influenced by inspiratory muscle exercise in patients with type 2 diabetes? Study protocol for a randomized controlled trial.

    PubMed

    Schein, Aso; Correa, Aps; Casali, Karina Rabello; Schaan, Beatriz D

    2016-01-20

    Physical exercise reduces glucose levels and glucose variability in patients with type 2 diabetes. Acute inspiratory muscle exercise has been shown to reduce these parameters in a small group of patients with type 2 diabetes, but these results have yet to be confirmed in a well-designed study. The aim of this study is to investigate the effect of acute inspiratory muscle exercise on glucose levels, glucose variability, and cardiovascular autonomic function in patients with type 2 diabetes. This study will use a randomized clinical trial crossover design. A total of 14 subjects will be recruited and randomly allocated to two groups to perform acute inspiratory muscle loading at 2 % of maximal inspiratory pressure (PImax, placebo load) or 60 % of PImax (experimental load). Inspiratory muscle training could be a novel exercise modality to be used to decrease glucose levels and glucose variability. ClinicalTrials.gov NCT02292810 .

  11. Nasal symptoms following endoscopic transsphenoidal pituitary surgery: assessment using the General Nasal Patient Inventory.

    PubMed

    Wang, Yi Yuen; Srirathan, Vinothan; Tirr, Erica; Kearney, Tara; Gnanalingham, Kanna K

    2011-04-01

    The endoscopic approach for pituitary tumors is a recent innovation and is said to reduce the nasal trauma associated with transnasal transsphenoidal surgery. The authors assessed the temporal changes in the rhinological symptoms following endoscopic transsphenoidal surgery for pituitary lesions, using the General Nasal Patient Inventory (GNPI). The GNPI was administered to 88 consecutive patients undergoing endoscopic transsphenoidal surgery at 3 time points (presurgery, 3-6 months postsurgery, and at final follow-up). The total GNPI score and the scores for the individual GNPI questions were calculated and differences between groups were assessed once before surgery, several months after surgery, and at final follow-up. Of a maximum possible score of 135, the mean GNPI score at 3-6 months postsurgery was only 12.9 ± 12 and was not significantly different from the preoperative score (10.4 ± 13) or final follow-up score (10.3 ± 10). Patients with functioning tumors had higher GNPI scores than those with nonfunctioning tumors for each of these time points (p < 0.05). Individually, a mild increase in symptom severity was seen for symptoms attributable to the nasal trauma of surgery, with partial recovery (nasal sores and bleeding) or complete recovery (nasal blockage, painful sinuses, and unpleasant nasal smell) by final follow-up (p < 0.05). Progressive improvements in symptom severity were seen for symptoms more attributable to tumor mass preoperatively (for example, headaches and painkiller use [p < 0.05]). In total, by final follow-up 8 patients (9%) required further treatment or advice for ongoing nasal symptoms. Endoscopic transsphenoidal surgery is a well-tolerated minimally invasive procedure for pituitary fossa lesions. Overall patient-assessed nasal symptoms do not change, but some individual symptoms may show a mild worsening or overall improvement.

  12. Adjuncts to Improve Nasal Reconstruction Results.

    PubMed

    Gordon, Shayna Lee; Hurst, Eva A

    2017-02-01

    The final cosmetic appearance of nasal reconstruction scars is of paramount importance to both the patient and surgeon. Ideal postreconstruction nasal scars are flat and indistinguishable from surrounding skin. Unfortunately, even with meticulous surgical execution, nasal scars can occasionally be suboptimal. Abnormal fibroblast response can lead to hypertrophic nasal scars, and excessive angiogenesis may lead to telangiectasias or an erythematous scar. Imperfect surgical closure or poor postoperative management can lead to surgical outcomes with step-offs, depressions, suture marks, or dyspigmentation. Aesthetically unacceptable nasal scars can cause pruritus, tenderness, pain, sleep disturbance, and anxiety and depression in postsurgical patients. Fortunately, there are several minimally invasive or noninvasive techniques that allow for enhancement and improvement of cosmetic results with minimal risk and associated downtime. This article provides an overview of adjuncts to improve nasal reconstruction with a focus on techniques to be used in the postoperative period. Armed with an understanding of relevant available therapies, skillful surgeons may drastically improve the final cosmesis and outcome of nasal reconstruction scars. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Cycle ergometer and inspiratory muscle training offer modest benefit compared with cycle ergometer alone: a comprehensive assessment in stable COPD patients

    PubMed Central

    Luo, Yu-wen; Wang, Mei; Hu, Yu-he; Xu, Wen-hui; Zhou, Lu-qian; Chen, Rong-chang; Chen, Xin

    2017-01-01

    Background Cycle ergometer training (CET) has been shown to improve exercise performance of the quadriceps muscles in patients with COPD, and inspiratory muscle training (IMT) may improve the pressure-generating capacity of the inspiratory muscles. However, the effects of combined CET and IMT remain unclear and there is a lack of comprehensive assessment. Materials and methods Eighty-one patients with COPD were randomly allocated to three groups: 28 received 8 weeks of CET + IMT (combined training group), 27 received 8 weeks of CET alone (CET group), and 26 only received 8 weeks of free walking (control group). Comprehensive assessment including respiratory muscle strength, exercise capacity, pulmonary function, dyspnea, quality of life, emotional status, nutritional status, and body mass index, airflow obstruction, and exercise capacity index were measured before and after the pulmonary rehabilitation program. Results Respiratory muscle strength, exercise capacity, inspiratory capacity, dyspnea, quality of life, depression and anxiety, and nutritional status were all improved in the combined training and CET groups when compared with that in the control group (P<0.05) after pulmonary rehabilitation program. Inspiratory muscle strength increased significantly in the combined training group when compared with that in the CET group (ΔPImax [maximal inspiratory pressure] 5.20±0.89 cmH2O vs 1.32±0.91 cmH2O; P<0.05). However, there were no significant differences in the other indices between the two groups (P>0.05). Patients with weakened respiratory muscles in the combined training group derived no greater benefit than those without respiratory muscle weakness (P>0.05). There were no significant differences in these indices between the patients with malnutrition and normal nutrition after pulmonary rehabilitation program (P>0.05). Conclusion Combined training is more effective than CET alone for increasing inspiratory muscle strength. IMT may not be useful when

  14. Comparison of peak inspiratory flow rate via the Breezhaler®, Ellipta® and HandiHaler® dry powder inhalers in patients with moderate to very severe COPD: a randomized cross-over trial.

    PubMed

    Altman, Pablo; Wehbe, Luis; Dederichs, Juergen; Guerin, Tadhg; Ament, Brian; Moronta, Miguel Cardenas; Pino, Andrea Valeria; Goyal, Pankaj

    2018-06-14

    The chronic and progressive nature of chronic obstructive pulmonary disease (COPD) requires self-administration of inhaled medication. Dry powder inhalers (DPIs) are increasingly being used for inhalation therapy in COPD. Important considerations when selecting DPIs include inhalation effort required and flow rates achieved by patients. Here, we present the comparison of the peak inspiratory flow rate (PIF) values achieved by COPD patients, with moderate to very severe airflow limitation, through the Breezhaler®, the Ellipta® and the HandiHaler® inhalers. The effects of disease severity, age and gender on PIF rate were also evaluated. This randomized, open-label, multicenter, cross-over, Phase IV study recruited patients with moderate to very severe airflow limitation (Global Initiative for Obstructive Lung Disease 2014 strategy), aged ≥40 years and having a smoking history of ≥10 pack years. No active drug or placebo was administered during the study. The inhalation profiles were recorded using inhalers fitted with a pressure tap and transducer at the wall of the mouthpiece. For each patient, the inhalation with the highest PIF value, out of three replicate inhalations per device, was selected for analysis. A paired t-test was performed to compare mean PIFs between each combination of devices. In total, 97 COPD patients were enrolled and completed the study. The highest mean PIF value (L/min ± SE) was observed with the Breezhaler® (108 ± 23), followed by the Ellipta® (78 ± 15) and the HandiHaler® (49 ± 9) inhalers and the lowest mean pressure drop values were recorded with the Breezhaler® inhaler, followed by the Ellipta® inhaler and the HandiHaler® inhaler, in the overall patient population. A similar trend was consistently observed in patients across all subgroups of COPD severity, within all age groups and for both genders. Patients with COPD were able to inhale with the least inspiratory effort and generate the highest mean

  15. Presurgical Nasal Molding With a Nasal Spring in Patients With Mild-to-Moderate Nasal Deformity With Incomplete Unilateral Cleft Lip With or Without Cleft Palate.

    PubMed

    Peanchitlertkajorn, Supakit

    2018-01-01

    Traditional nasoalveolar molding (NAM) requires steep learning curve for clinicians and significant compliance from parents. Nasal springs have been developed by the author to simplify presurgical nasal molding. This article presents the design, construction, and application of the spring. The treatment goal is to improve nasal deformity prior to primary repair in infants born with incomplete unilateral cleft lip with or without cleft palate. The design, fabrication, and utility of the nasal spring are described. The spring has a simpler design and construction compared to a traditional NAM appliance. Two patients with incomplete unilateral cleft lip with and without cleft palate are presented. The spring is constructed and delivered. The active arm of the spring can be 3-dimensionally (3-D) adjusted to mold the alar cartilage of the affected nostril. The spring does not require an oral plate for adherence as a traditional NAM appliance does, hence an oral impression is not needed. The spring is easy for clinicians to adjust. It also requires less compliance by parents. Main Outcome Measures/Results: The presurgical molding achieved by the use of a nasal spring improved surgical nasolabial aesthetic outcomes. The nasal springs are effective in reducing the initial cleft nasal deformity. This facilitates primary surgical cleft lip and nose correction and improves surgical outcomes in patients with incomplete unilateral cleft lip with or without cleft palate.

  16. Management of Intractable Nasal Hyperreactivity by Selective Resection of Posterior Nasal Nerve Branches

    PubMed Central

    Takahara, Daisuke; Hamamoto, Takao; Ishino, Takashi; Hirakawa, Katsuhiro

    2017-01-01

    The posterior nasal nerves emerge from the sphenopalatine foramen and contain sensory and autonomic nerve components. Posterior nasal neurectomy is an effective method to remove pathological neural networks surrounding the inferior turbinate that cause unregulated nasal hypersensitivity with excess secretion in patients with severe allergic rhinitis (AR). We describe the sophisticated endoscopic surgical procedure that allows feasible access to the confined area and selective resection of the nerve branches with the preservation of the sphenopalatine artery (SPA). We retrospectively analyzed the cases of 23 symptomatic severe AR patients who failed to respond to standard medical treatment and underwent surgery. There have been no major complications after surgery including nasal bleeding or transient numbness of the upper teeth. The mean total nasal symptom scores (TNSS) were decreased by 70.2% at 12 months after the procedure. Our comparison of the clinical effectiveness based on the number of severed nerve branches revealed that the improvement of the TNSS was significantly higher in patients with >2 branches. We conclude that this minimally invasive technique that preserves the SPA is clinically useful and decreases the rate of postoperative complications. This trial is registered with UMIN000029025. PMID:29379524

  17. Management of Intractable Nasal Hyperreactivity by Selective Resection of Posterior Nasal Nerve Branches.

    PubMed

    Takahara, Daisuke; Takeno, Sachio; Hamamoto, Takao; Ishino, Takashi; Hirakawa, Katsuhiro

    2017-01-01

    The posterior nasal nerves emerge from the sphenopalatine foramen and contain sensory and autonomic nerve components. Posterior nasal neurectomy is an effective method to remove pathological neural networks surrounding the inferior turbinate that cause unregulated nasal hypersensitivity with excess secretion in patients with severe allergic rhinitis (AR). We describe the sophisticated endoscopic surgical procedure that allows feasible access to the confined area and selective resection of the nerve branches with the preservation of the sphenopalatine artery (SPA). We retrospectively analyzed the cases of 23 symptomatic severe AR patients who failed to respond to standard medical treatment and underwent surgery. There have been no major complications after surgery including nasal bleeding or transient numbness of the upper teeth. The mean total nasal symptom scores (TNSS) were decreased by 70.2% at 12 months after the procedure. Our comparison of the clinical effectiveness based on the number of severed nerve branches revealed that the improvement of the TNSS was significantly higher in patients with >2 branches. We conclude that this minimally invasive technique that preserves the SPA is clinically useful and decreases the rate of postoperative complications. This trial is registered with UMIN000029025.

  18. [Disturbances of nasal aerodynamics in patients with the curved nasal septum and the rationale for its surgical correction].

    PubMed

    Tulebaev, R K; Mustafin, A A; Zholdybaeva, Z T

    2011-01-01

    Serious disturbances of nasal aerodynamics contribute to the development of diseases of the broncho-pulmonary apparatus. The early recognition of ventilation problems in patients with the curved nasal septum is paramount for the efficacious prevention and treatment of respiratory complications. The authors describe principles of rhinosurgical correction of affected nasal aerodynamics in patients with the curved nasal septum.

  19. A Nasal Epithelial Receptor for Staphylococcus aureus WTA Governs Adhesion to Epithelial Cells and Modulates Nasal Colonization

    PubMed Central

    Faulstich, Manuela; Grau, Timo; Severin, Yannik; Unger, Clemens; Hoffmann, Wolfgang H.; Rudel, Thomas; Autenrieth, Ingo B.; Weidenmaier, Christopher

    2014-01-01

    Nasal colonization is a major risk factor for S. aureus infections. The mechanisms responsible for colonization are still not well understood and involve several factors on the host and the bacterial side. One key factor is the cell wall teichoic acid (WTA) of S. aureus, which governs direct interactions with nasal epithelial surfaces. We report here the first receptor for the cell wall glycopolymer WTA on nasal epithelial cells. In several assay systems this type F-scavenger receptor, termed SREC-I, bound WTA in a charge dependent manner and mediated adhesion to nasal epithelial cells in vitro. The impact of WTA and SREC-I interaction on epithelial adhesion was especially pronounced under shear stress, which resembles the conditions found in the nasal cavity. Most importantly, we demonstrate here a key role of the WTA-receptor interaction in a cotton rat model of nasal colonization. When we inhibited WTA mediated adhesion with a SREC-I antibody, nasal colonization in the animal model was strongly reduced at the early onset of colonization. More importantly, colonization stayed low over an extended period of 6 days. Therefore we propose targeting of this glycopolymer-receptor interaction as a novel strategy to prevent or control S. aureus nasal colonization. PMID:24788600

  20. High-flow nasal oxygen vs. standard oxygen therapy in immunocompromised patients with acute respiratory failure: study protocol for a randomized controlled trial.

    PubMed

    Azoulay, Elie; Lemiale, Virginie; Mokart, Djamel; Nseir, Saad; Argaud, Laurent; Pène, Frédéric; Kontar, Loay; Bruneel, Fabrice; Klouche, Kada; Barbier, François; Reignier, Jean; Stoclin, Anabelle; Louis, Guillaume; Constantin, Jean-Michel; Mayaux, Julien; Wallet, Florent; Kouatchet, Achille; Peigne, Vincent; Perez, Pierre; Girault, Christophe; Jaber, Samir; Oziel, Johanna; Nyunga, Martine; Terzi, Nicolas; Bouadma, Lila; Lebert, Christine; Lautrette, Alexandre; Bigé, Naike; Raphalen, Jean-Herlé; Papazian, Laurent; Rabbat, Antoine; Darmon, Michael; Chevret, Sylvie; Demoule, Alexandre

    2018-03-05

    Acute respiratory failure (ARF) is the leading reason for intensive care unit (ICU) admission in immunocompromised patients. High-flow nasal oxygen (HFNO) therapy is an alternative to standard oxygen. By providing warmed and humidified gas, HFNO allows the delivery of higher flow rates via nasal cannula devices, with FiO 2 values of nearly 100%. Benefits include alleviation of dyspnea and discomfort, decreased respiratory distress and decreased mortality in unselected patients with acute hypoxemic respiratory failure. However, in preliminary reports, HFNO benefits are controversial in immunocompromised patients in whom it has never been properly evaluated. This is a multicenter, open-label, randomized controlled superiority trial in 30 intensive care units, part of the Groupe de Recherche Respiratoire en Réanimation Onco-Hématologique (GRRR-OH). Inclusion criteria will be: (1) adults, (2) known immunosuppression, (3) ARF, (4) oxygen therapy ≥ 6 L/min, (5) written informed consent from patient or proxy. Exclusion criteria will be: (1) imminent death (moribund patient), (2) no informed consent, (3) hypercapnia (PaCO 2 ≥ 50 mmHg), (4) isolated cardiogenic pulmonary edema, (5) pregnancy or breastfeeding, (6) anatomical factors precluding insertion of a nasal cannula, (7) no coverage by the French statutory healthcare insurance system, and (8) post-surgical setting from day 1 to day 6 (patients with ARF occurring after day 6 of surgery can be included). The primary outcome measure is day-28 mortality. Secondary outcomes are intubation rate, comfort, dyspnea, respiratory rate, oxygenation, ICU length of stay, and ICU-acquired infections. Based on an expected 30% mortality rate in the standard oxygen group, and 20% in the HFNO group, error rate set at 5%, and a statistical power at 90%, 389 patients are required in each treatment group (778 patients overall). Recruitment period is estimated at 30 months, with 28 days of additional follow-up for the last included

  1. Oxymetazoline plus dexpanthenol in nasal congestion.

    PubMed

    Jagade, Mohan V; Langade, Deepak G; Pophale, Rupesh R; Prabhu, Arun

    2008-12-01

    To compare the efficacy and tolerability of Oxymetazoline 0.05 % plus Dexpanthanol 5% versus Xylometazoline 0.1 % nasal drops in patients with nasal congestion due to allergic rhinitis and following nasal surgery. An investigator-blind, randomized, controlled, phase IV clinical trial conducted in 100 patients with acute allergic rhinitis or patients post-nasal surgery. Patients received either Oxymetazoline 0.05% with Dexpanthanol 5% (OD) or Xylometazoline 0.1% (XO) nasal drops. Relief from nasal congestion was significantly better in the OD group then in the XO group (mean nasal scores 1.24 vs 1.86). Significantly more improvement in sneezing and decrease in nasal discharge was seen in the OD group than the XO group. Nasal irritation in the OD group was significantly less as compared to XO group (0.38 v/s 1.12 on second day and 0.10 vs 0.36 on the fourth day). The recovery time for OD group was 1.08 hours, which was significantly (46 min) lesser than that of the XO group. Rebound congestion was significantly less in OD as compared to XO group (6.25% vs 82.98%). 93.75% of the physicians in the OD group and 51.28% in XO group reported response to therapy as good to excellent. 95.83% patients in the OD group and only 52.91% patients in the XO group rated tolerability to therapy as good to excellent. Oxymetazoline and dexpanthenol combination has a better efficacy, shorter recovery time, causes lesser rebound congestion and has better tolerability than xylometazoline.

  2. Functional assessment of the diaphragm by speckle tracking ultrasound during inspiratory loading.

    PubMed

    Oppersma, Eline; Hatam, Nima; Doorduin, Jonne; van der Hoeven, Johannes G; Marx, Gernot; Goetzenich, Andreas; Fritsch, Sebastian; Heunks, Leo M A; Bruells, Christian S

    2017-11-01

    Assessment of diaphragmatic effort is challenging, especially in critically ill patients in the phase of weaning. Fractional thickening during inspiration assessed by ultrasound has been used to estimate diaphragm effort. It is unknown whether more sophisticated ultrasound techniques such as speckle tracking are superior in the quantification of inspiratory effort. This study evaluates the validity of speckle tracking ultrasound to quantify diaphragm contractility. Thirteen healthy volunteers underwent a randomized stepwise threshold loading protocol of 0-50% of the maximal inspiratory pressure. Electric activity of the diaphragm and transdiaphragmatic pressures were recorded. Speckle tracking ultrasound was used to assess strain and strain rate as measures of diaphragm tissue deformation and deformation velocity, respectively. Fractional thickening was assessed by measurement of diaphragm thickness at end-inspiration and end-expiration. Strain and strain rate increased with progressive loading of the diaphragm. Both strain and strain rate were highly correlated to transdiaphragmatic pressure (strain r 2  = 0.72; strain rate r 2  = 0.80) and diaphragm electric activity (strain r 2  = 0.60; strain rate r 2  = 0.66). We conclude that speckle tracking ultrasound is superior to conventional ultrasound techniques to estimate diaphragm contractility under inspiratory threshold loading. NEW & NOTEWORTHY Transdiaphragmatic pressure using esophageal and gastric balloons is the gold standard to assess diaphragm effort. However, this technique is invasive and requires expertise, and the interpretation may be complex. We report that speckle tracking ultrasound can be used to detect stepwise increases in diaphragmatic effort. Strain and strain rate were highly correlated with transdiaphragmatic pressure, and therefore, diaphragm electric activity and speckle tracking might serve as reliable tools to quantify diaphragm effort in the future. Copyright © 2017 the

  3. The role of inspiratory muscle training in the management of asthma and exercise-induced bronchoconstriction.

    PubMed

    Shei, Ren-Jay; Paris, Hunter L R; Wilhite, Daniel P; Chapman, Robert F; Mickleborough, Timothy D

    2016-11-01

    Asthma is a pathological condition comprising of a variety of symptoms which affect the ability to function in daily life. Due to the high prevalence of asthma and associated healthcare costs, it is important to identify low-cost alternatives to traditional pharmacotherapy. One of these low cost alternatives is the use of inspiratory muscle training (IMT), which is a technique aimed at increasing the strength and endurance of the diaphragm and accessory muscles of respiration. IMT typically consists of taking voluntary inspirations against a resistive load across the entire range of vital capacity while at rest. In healthy individuals, the most notable benefits of IMT are an increase in diaphragm thickness and strength, a decrease in exertional dyspnea, and a decrease in the oxygen cost of breathing. Due to the presence of expiratory flow limitation in asthma and exercise-induced bronchoconstriction, dynamic lung hyperinflation is common. As a result of varying operational lung volumes, due in part to hyperinflation, the respiratory muscles may operate far from the optimal portion of the length-tension curve, and thus may be forced to operate against a low pulmonary compliance. Therefore, the ability of these muscles to generate tension is reduced, and for any given level of ventilation, the work of breathing is increased as compared to non-asthmatics. Evidence that IMT is an effective treatment for asthma is inconclusive, due to limited data and a wide variation in study methodologies. However, IMT has been shown to decrease dyspnea, increase inspiratory muscle strength, and improve exercise capacity in asthmatic individuals. In order to develop more concrete recommendations regarding IMT as an effective low-cost adjunct in addition to traditional asthma treatments, we recommend that a standard treatment protocol be developed and tested in a placebo-controlled clinical trial with a large representative sample.

  4. Nasal dermoid sinus cyst.

    PubMed

    Cauchois, R; Laccourreye, O; Bremond, D; Testud, R; Küffer, R; Monteil, J P

    1994-08-01

    Nasal dermoid sinus cyst is one of the diagnoses of midline nasal masses in children. This retrospective study analyzes the various theories regarding the origin of this congenital abnormality, the differential diagnosis, and the value of magnetic resonance imaging, as well as the various surgical options available.

  5. Speech rate reduction and "nasality" in normal speakers.

    PubMed

    Brancewicz, T M; Reich, A R

    1989-12-01

    This study explored the effects of reduced speech rate on nasal/voice accelerometric measures and nasality ratings. Nasal/voice accelerometric measures were obtained from normal adults for various speech stimuli and speaking rates. Stimuli included three sentences (one obstruent-loaded, one semivowel-loaded, and one containing a single nasal), and /pv/ syllable trains.. Speakers read the stimuli at their normal rate, half their normal rate, and as slowly as possible. In addition, a computer program paced each speaker at rates of 1, 2, and 3 syllables per second. The nasal/voice accelerometric values revealed significant stimulus effects but no rate effects. The nasality ratings of experienced listeners, evaluated as a function of stimulus and speaking rate, were compared to the accelerometric measures. The nasality scale values demonstrated small, but statistically significant, stimulus and rate effects. However, the nasality percepts were poorly correlated with the nasal/voice accelerometric measures.

  6. The activity of N-acetyl-β-d-hexosaminidase A and B and β-glucuronidase in nasal polyps and hypertrophic nasal concha.

    PubMed

    Chojnowska, Sylwia; Minarowska, Alina; Waszkiewicz, Napoleon; Kępka, Alina; Zalewska-Szajda, Beata; Gościk, Elżbieta; Kowal, Krzysztof; Olszewska, Ewa; Konarzewska-Duchnowska, Emilia; Minarowski, Łukasz; Zwierz, Krzysztof; Ładny, Jerzy Robert; Szajda, Sławomir Dariusz

    2014-01-01

    Nasal polyps and hypertrophic lower nasal conchae are common disorders of nasal cavity. The majority of etiopathogenetic theories indicate inflammatory background of polyps and hypertrophic concha. N-acetyl-β-D-hexosaminidase and β-glucuronidase are lysosomal exoglycosidases revealing accelerated activity in inflammatory processes. The aim of the study was to evaluate the catabolism of glycoconjugates in nasal polyps and hypertrophic nasal concha basing on the activity of N-acetyl-β-D-hexosaminidase (HEX) and β-glucuronidase (GLU). Material consisted of nasal polyps taken from 40 patients during polypectomy in patients with chronic rhinosinusitis with nasal polyps (CRSwNP) and hypertrophic lower nasal conchae taken from 20 patients during mucotomy. The activity of HEX, HEX A, HEX B and GLU in supernatant of homogenates of nasal polyps and hypertrophic lower nasal concha tissues has been estimated using colorimetric method. Statistically significant decrease has been observed in concentration of the activity (per 1mg of tissue) of HEX (p<0.05), HEX B (p<0.001) and specific activity (per 1mg of protein) of HEX B (p<0.001) in nasal polyps tissue in comparison to hypertrophic lower nasal conchae tissue. Decrease in the activity and specific activity concentration of the majority of examined lysosomal exoglycosidases (increasing in inflammations) in comparison to hypertrophic lower nasal conchae suggests electrolytes disorders and questions the inflammatory background of nasal polyps. Copyright © 2013 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  7. Stimulation of respiratory changes in alae nasi length by chemoreceptor activation.

    PubMed

    Van Lunteren, E; Haxhiu, M A; Cherniack, N S

    1986-03-01

    Respiratory-related changes in length of the nasal dilator muscle, the alae nasi muscle, were measured using sonomicrometry in ten anesthetized (pentobarbital), tracheostomized, spontaneously breathing dogs. Piezoelectric crystals were inserted 7-25 mm apart along the direction of the alae nasi muscle fibers, and the effects of progressive hyperoxic hypercapnia and a peripheral and central chemoreceptor stimulant, nicotine (10-500 micrograms intravenously), were ascertained. The alae nasi shortened during inspiration in all animals, started to lengthen again towards the end of inspiration, returned to resting length during the first portion of expiration (Te-1), and remained at resting length for the remainder of expiration (Te-2). The amount of alae nasi inspiratory shortening was increased by occluding the airway for a single breath. Progressive hypercapnia caused progressive increases in the amount and velocity of nasal muscle inspiratory shortening during both unoccluded and occluded breaths; similar stimulatory effects on inspiratory shortening were seen following nicotine administration. Furthermore, both chemoreceptor stimulants caused a delay in the return of the muscle to its resting length during expiration, resulting in a significant increase in Te-1 relative to Te (Te-1/Te), and a greater amount of nasal muscle shortening to be present during Te-1. In some animals these agents also caused tonic shortening of the alae nasi, so that the muscle never returned to its resting length. These results suggest that inspiratory shortening of the alae nasi is inhibited by vagal inputs, but that chemoreceptor activation increases the amount of muscle shortening during both inspiration and early expiration.

  8. Application of an inline dry powder inhaler to deliver high dose pharmaceutical aerosols during low flow nasal cannula therapy.

    PubMed

    Farkas, Dale; Hindle, Michael; Longest, P Worth

    2018-05-05

    Inline dry powder inhalers (DPIs) offer a potentially effective option to deliver high dose inhaled medications simultaneously with mechanical ventilation. The objective of this study was to develop an inline DPI that is actuated using a low volume of air (LV-DPI) to efficiently deliver pharmaceutical aerosols during low flow nasal cannula (LFNC) therapy. A characteristic feature of the new inline LV-DPIs was the use of hollow capillary tubes that both pierced the capsule and provided a pathway for inlet air and exiting aerosol. Aerosolization characteristics, LFNC depositional losses and emitted dose (ED) were determined using 10 mg powder masses of a small-particle excipient enhanced growth (EEG) formulation. While increasing the number of inlet capillaries from one to three did not improve performance, retracting the inlet and outlet capillaries did improve ED by over 30%. It was theorized that high quality performance requires both high turbulent energy to deaggregate the powder and high wall shear stresses to minimize capsule retention. Best case performance included a device ED of approximately 85% (of loaded dose) and device emitted mass median aerodynamic diameter of 1.77 µm. Maximum ED through the LFNC system and small diameter (4 mm) nasal cannula was approximately 65% of the loaded dose. Potential applications of this device include the delivery of high dose inhaled medications such as surfactants, antibiotics, mucolytics, and anti-inflammatories. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Distilled water nasal provocation in hyperreactive patients.

    PubMed

    Baudoin, T; Anzic, S A; Kalogjera, L

    1999-01-01

    Nonisotonic aerosol may act as a provocation agent in the upper and lower airways of hyperreactive individuals. The purpose of the study was to compare the results of nasal challenge with distilled water in patients with allergic rhinitis to those with noninfective nonallergic rhinitis (NINAR), with respect to the potential clinical use of the obtained data. A group of 68 ambulatory patients with allergic rhinitis or NINAR (39 perennial allergic, 6 seasonal, 23 NINAR) were challenged with 10 mL of distilled water aerosol after the baseline active anterior rhinomanometry. Patients with nasal polyposis at endoscopy, significant unilateral septal deviation, positive bacteriologic swab, recent nasal surgery, and uncertain anamnestic data about the medication taken 6 weeks before the provocation were excluded from the study. After 10 minutes of nasal provocation, rhinomanometry was repeated to assess the response. In 15 patients of the perennial allergic group, the same measurements were performed after a 2-week oral antihistamine and topical steroid therapy. Nasal resistance was significantly increased on the more patent side of the nose after nasal provocation with distilled water aerosol in allergic patients in comparison to the nasal resistance before provocation. In the patients with NINAR, the provocation resulted in a significant rise on the more patent side, but the total nasal airway resistance (NAR) levels were also significantly increased. The systemic antihistamine and topical steroid 2-week therapy in patients with perennial allergic rhinitis significantly reduced the response to nasal distilled water provocation. Nasal provocation with distilled water aerosol is a cheap, simple, and acceptable method that provides useful clinical data on the level of nonspecific nasal hyperreactivity and the therapy success.

  10. A Computational Study of the Hydrodynamics in the Nasal Region of a Hammerhead Shark (Sphyrna tudes): Implications for Olfaction

    PubMed Central

    Rygg, Alex D.; Cox, Jonathan P. L.; Abel, Richard; Webb, Andrew G.; Smith, Nadine B.; Craven, Brent A.

    2013-01-01

    The hammerhead shark possesses a unique head morphology that is thought to facilitate enhanced olfactory performance. The olfactory chambers, located at the distal ends of the cephalofoil, contain numerous lamellae that increase the surface area for olfaction. Functionally, for the shark to detect chemical stimuli, water-borne odors must reach the olfactory sensory epithelium that lines these lamellae. Thus, odorant transport from the aquatic environment to the sensory epithelium is the first critical step in olfaction. Here we investigate the hydrodynamics of olfaction in Sphyrna tudes based on an anatomically-accurate reconstruction of the head and olfactory chamber from high-resolution micro-CT and MRI scans of a cadaver specimen. Computational fluid dynamics simulations of water flow in the reconstructed model reveal the external and internal hydrodynamics of olfaction during swimming. Computed external flow patterns elucidate the occurrence of flow phenomena that result in high and low pressures at the incurrent and excurrent nostrils, respectively, which induces flow through the olfactory chamber. The major (prenarial) nasal groove along the cephalofoil is shown to facilitate sampling of a large spatial extent (i.e., an extended hydrodynamic “reach”) by directing oncoming flow towards the incurrent nostril. Further, both the major and minor nasal grooves redirect some flow away from the incurrent nostril, thereby limiting the amount of fluid that enters the olfactory chamber. Internal hydrodynamic flow patterns are also revealed, where we show that flow rates within the sensory channels between olfactory lamellae are passively regulated by the apical gap, which functions as a partial bypass for flow in the olfactory chamber. Consequently, the hammerhead shark appears to utilize external (major and minor nasal grooves) and internal (apical gap) flow regulation mechanisms to limit water flow between the olfactory lamellae, thus protecting these delicate

  11. Nasal microenvironments and interspecific interactions influence nasal microbiota complexity and S. aureus carriage.

    PubMed

    Yan, Miling; Pamp, Sünje J; Fukuyama, Julia; Hwang, Peter H; Cho, Do-Yeon; Holmes, Susan; Relman, David A

    2013-12-11

    The indigenous microbiota of the nasal cavity plays important roles in human health and disease. Patterns of spatial variation in microbiota composition may help explain Staphylococcus aureus colonization and reveal interspecies and species-host interactions. To assess the biogeography of the nasal microbiota, we sampled healthy subjects, representing both S. aureus carriers and noncarriers at three nasal sites (anterior naris, middle meatus, and sphenoethmoidal recess). Phylogenetic compositional and sparse linear discriminant analyses revealed communities that differed according to site epithelium type and S. aureus culture-based carriage status. Corynebacterium accolens and C. pseudodiphtheriticum were identified as the most important microbial community determinants of S. aureus carriage, and competitive interactions were only evident at sites with ciliated pseudostratified columnar epithelium. In vitro cocultivation experiments provided supporting evidence of interactions among these species. These results highlight spatial variation in nasal microbial communities and differences in community composition between S. aureus carriers and noncarriers. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Nasal microenvironments and interspecific interactions influence nasal microbiota complexity and S. aureus carriage

    PubMed Central

    Yan, Miling; Pamp, Sünje J.; Fukuyama, Julia; Hwang, Peter H.; Cho, Do-Yeon; Holmes, Susan; Relman, David A.

    2013-01-01

    Summary The indigenous microbiota of the nasal cavity plays important roles in human health and disease. Patterns of spatial variation in microbiota composition may help explain Staphylococcus aureus colonization, and reveal interspecies and species-host interactions. To assess the biogeography of the nasal microbiota, we sampled healthy subjects, representing both S. aureus carriers and non-carriers, at 3 nasal sites (anterior naris, middle meatus, and sphenoethmoidal recess). Phylogenetic compositional and sparse linear discriminant analyses revealed communities that differed according to site epithelium type and S. aureus culture-based carriage status. Corynebacterium accolens and C. pseudodiphtheriticum were identified as the most important microbial community determinants of S. aureus carriage, with competitive interactions evident only at sites with ciliated pseudostratified columnar epithelium. In vitro co-cultivation experiments provided supporting evidence of interactions among these species. These results highlight spatial variation in nasal microbial communities and differences in community composition between S. aureus carriers and non-carriers. PMID:24331461

  13. Simulating the nasal cycle with computational fluid dynamics

    PubMed Central

    Patel, Ruchin G.; Garcia, Guilherme J. M.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.

    2015-01-01

    Objectives (1) Develop a method to account for the confounding effect of the nasal cycle when comparing pre- and post-surgery objective measures of nasal patency. (2) Illustrate this method by reporting objective measures derived from computational fluid dynamics (CFD) models spanning the full range of mucosal engorgement associated with the nasal cycle in two subjects. Study Design Retrospective Setting Academic tertiary medical center. Subjects and Methods A cohort of 24 nasal airway obstruction patients was reviewed to select the two patients with the greatest reciprocal change in mucosal engorgement between pre- and post-surgery computed tomography (CT) scans. Three-dimensional anatomic models were created based on the pre- and post-operative CT scans. Nasal cycling models were also created by gradually changing the thickness of the inferior turbinate, middle turbinate, and septal swell body. CFD was used to simulate airflow and to calculate nasal resistance and average heat flux. Results Before accounting for the nasal cycle, Patient A appeared to have a paradoxical worsening nasal obstruction in the right cavity postoperatively. After accounting for the nasal cycle, Patient A had small improvements in objective measures postoperatively. The magnitude of the surgical effect also differed in Patient B after accounting for the nasal cycle. Conclusion By simulating the nasal cycle and comparing models in similar congestive states, surgical changes in nasal patency can be distinguished from physiological changes associated with the nasal cycle. This ability can lead to more precise comparisons of pre and post-surgery objective measures and potentially more accurate virtual surgery planning. PMID:25450411

  14. Importance to question sinonasal symptoms and to perform rhinoscopy and rhinomanometry in cystic fibrosis patients.

    PubMed

    Bock, J M; Schien, M; Fischer, C; Naehrlich, L; Kaeding, M; Guntinas-Lichius, O; Gerber, A; Arnold, C; Mainz, J G

    2017-02-01

    Cystic fibrosis (CF) patients almost regularly reveal sinonasal pathology. The purpose of this study was to assess association between objective and subjective measurements of sinonasal involvement comparing nasal airflow obtained by active anterior rhinomanometry (AAR), nasal endoscopic findings, and symptoms assessed with the Sino-Nasal Outcome Test-20 (SNOT-20). Nasal cavities were explored by anterior rigid rhinoscopy and findings were compared to inspiratory nasal airflow measured by AAR to quantify nasal patency and subjective health-related quality of life in sinonasal disease obtained with the SNOT-20 questionnaire. Relations to upper and lower airway colonization with Pseudomonas aeruginosa, medical treatment, and sinonasal surgery were analysed. A total of 124 CF patients were enrolled (mean age 19.9 ± 10.4 years, range 4-65 years). A significant association of detection of nasal polyposis (NP) in rhinoscopy was found with increased primary nasal symptoms (PNS) which include "nasal obstruction," "sneezing," "runny nose," "thick nasal discharge," and "reduced sense of smell." At the same time patients with pathologically decreased airflow neither showed elevated SNOT-20 scores nor abnormal rhinoscopic findings. Altogether, rhinomanometric and rhinoscopic findings are not significantly related. Among SNOT-20 scores the PNS subscore is related to rhinoscopically detected polyposis and sinonasal secretion. Therefore, we recommend including short questions regarding PNS into CF-routine care. At the same time our results show that a high inspiratory airflow is not associated with a good sensation of nasal patency. Altogether, rhinomanometry is not required within routine CF-care, but it can be interesting as an outcome parameter within clinical trials. Pediatr Pulmonol. 2017;52:167-174. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. [Clinical analysis of nasal mucosa contact headache].

    PubMed

    Gu, Qingjia; Wen, Bei; Li, Jingxian; Fan, Jiangang; He, Gang

    2013-07-01

    To investigate the efficacy of nasal mucosa contact point headache with the treatment of endoscopic sinus surgery. Clinical data of 75 cases with nasal mucosa contact point headache treated in our department from Jan 2008 to Nov 2011 were retrospectively analyzed. These patients were performed with endoscopic sinus surgery. All patients were followed up for more than six months. They all achieved significant efficacy and no complications occurred. Nasal mucosa contact point headache and primary headache had different clinical features and different treatment. Misdiagnosis were easily made if not being carefully analyzed. Three lines tension relaxing septorhinoplasty combined with nasal bone fracture correction can achieve satisfactory curative effect and can effectively prevent the occurrence of complications. Therefore, it is necessary to strengthen the awareness of this disease. Nasal structure abnormality is the main reason of nasal mucosa contact point headache. The implementation of individualized nasal endoscopic sinus surgery can achieve satisfactory curative effect.

  16. Evaluation of In Vitro and In Vivo Flow Rate Dependency of Budesonide/Formoterol Easyhaler®

    PubMed Central

    Malmberg, L. Pekka; Everard, Mark L.; Haikarainen, Jussi

    2014-01-01

    Abstract Background: The Easyhaler® (EH) device-metered dry powder inhaler containing budesonide and formoterol is being developed for asthma and chronic obstructive pulmonary disease (COPD). As a part of product optimization, a series of in vitro and in vivo studies on flow rate dependency were carried out. Methods: Inspiratory flow parameters via EH and Symbicort® Turbuhaler® (TH) inhalers were evaluated in 187 patients with asthma and COPD. The 10th, 50th, and 90th percentile flow rates achieved by patients were utilized to study in vitro flow rate dependency of budesonide/formoterol EH and Symbicort TH. In addition, an exploratory pharmacokinetic study on pulmonary deposition of active substances for budesonide/formoterol EH in healthy volunteers was performed. Results: Mean inspiratory flow rates through EH were 64 and 56 L/min in asthmatics and COPD patients, and through TH 79 and 72 L/min, respectively. Children with asthma had marginally lower PIF values than the adults. The inspiratory volumes were similar in all groups between the inhalers. Using weighted 10th, 50th, and 90th percentile flows the in vitro delivered doses (DDs) and fine particle doses (FPDs) for EH were rather independent of flow as 98% of the median flow DDs and 89%–93% of FPDs were delivered already at 10th percentile air flow. Using±15% limits, EH and TH had similar flow rate dependency profiles between 10th and 90th percentile flows. The pharmacokinetic study with budesonide/formoterol EH in healthy subjects (n=16) revealed a trend for a flow-dependent increase in lung deposition for both budesonide and formoterol. Conclusions: Comparable in vitro flow rate dependency between budesonide/formoterol EH and Symbicort TH was found using the range of clinically relevant flow rates. The results of the pharmacokinetic study were in accordance with the in vitro results showing only a trend of flow rate-dependant increase in lung deposition of active substances with EH. PMID:24978441

  17. Using a high-flow nasal cannula provides superior results to OxyMask delivery in moderate to severe bronchiolitis: a randomized controlled study.

    PubMed

    Ergul, Ayse Betul; Calıskan, Emrah; Samsa, Hasan; Gokcek, Ikbal; Kaya, Ali; Zararsiz, Gozde Erturk; Torun, Yasemin Altuner

    2018-06-18

    The effectiveness of using a face mask with a small diffuser for oxygen delivery (OxyMask) was compared to use of a high-flow nasal cannula (HFNC) in patients with moderate or severe bronchiolitis.The study population in this open, phase 4, randomized controlled trial consisted of 60 patients aged 1-24 months diagnosed with moderate or severe bronchiolitis and admitted to an intensive care unit (ICU) for oxygen therapy. The patients were randomized into two groups according to the method of oxygen delivery: a diffuser mask group and an HFNC group.There were seven failures in the mask group and none in the HFNC group. The survival probability differed significantly between the two treatment methods (p = 0.009).Time to weaning off oxygen therapy was 56 h in the HFNC group and 96 h in the mask group (p < 0.001). HFNC use decreased the treatment failure rate and the duration of both oxygen therapy and ICU treatment compared to the diffuser mask, which implies that an HFNC should be the first choice for treating patients admitted to the ICU with severe bronchiolitis. What is known: • A high-flow nasal cannula (HFNC) does not significantly reduce the time on oxygen compared to standard therapy in children with moderate to severe bronchiolitis. Observational studies show that, since the introduction of HFNC, fewer children with bronchiolitis need intubation. For children with moderate to severe bronchiolitis there is no proof of its benefit. What Is New: • In children with moderate to severe bronchiolitis, HFNC provides faster and more effective improvement than can be achieved with a diffuser mask.

  18. Physiological effects and optimisation of nasal assist-control ventilation for patients with chronic obstructive pulmonary disease in respiratory failure

    PubMed Central

    Girault, C.; Chevron, V.; Richard, J. C.; Daudenthun, I.; Pasquis, P.; Leroy, J.; Bonmarchand, G.

    1997-01-01

    BACKGROUND: A study was undertaken to investigate the effects of non- invasive assist-control ventilation (ACV) by nasal mask on respiratory physiological parameters and comfort in acute on chronic respiratory failure (ACRF). METHODS: Fifteen patients with chronic obstructive pulmonary disease (COPD) were prospectively and randomly assigned to two non-invasive ventilation (NIV) sequences in spontaneous breathing (SB) and ACV mode. ACV settings were always optimised and therefore subsequently adjusted according to patient's tolerance and air leaks. RESULTS: ACV significantly decreased all the total inspiratory work of breathing (WOBinsp) parameters, pressure time product, and oesophageal pressure variation in comparison with SB mode. The ACV mode also resulted in a significant reduction in surface diaphragmatic electromyographic activity to 36% of the control values and significantly improved the breathing pattern. SB did not change the arterial blood gas tensions from baseline values whereas ACV significantly improved both the PaO2 from a mean (SD) of 8.45 (2.95) kPa to 13.31 (2.15) kPa, PaCO2 from 9.52 (1.61) kPa to 7.39 (1.39) kPa, and the pH from 7.32 (0.03) to 7.40 (0.07). The respiratory comfort was significantly lower with ACV than with SB. CONCLUSIONS: This study shows that the clinical benefit of non-invasive ACV in the management of ACRF in patients with COPD results in a reduced inspiratory muscle activity providing an improvement in breathing pattern and gas exchange. Despite respiratory discomfort, the muscle rest provided appears sufficient when ACV settings are optimised. 


 PMID:9337827

  19. Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia

    PubMed Central

    Mosing, Martina; Waldmann, Andreas D.; MacFarlane, Paul; Iff, Samuel; Auer, Ulrike; Bohm, Stephan H.; Bettschart-Wolfensberger, Regula; Bardell, David

    2016-01-01

    This study evaluated the breathing pattern and distribution of ventilation in horses prior to and following recovery from general anaesthesia using electrical impedance tomography (EIT). Six horses were anaesthetised for 6 hours in dorsal recumbency. Arterial blood gas and EIT measurements were performed 24 hours before (baseline) and 1, 2, 3, 4, 5 and 6 hours after horses stood following anaesthesia. At each time point 4 representative spontaneous breaths were analysed. The percentage of the total breath length during which impedance remained greater than 50% of the maximum inspiratory impedance change (breath holding), the fraction of total tidal ventilation within each of four stacked regions of interest (ROI) (distribution of ventilation) and the filling time and inflation period of seven ROI evenly distributed over the dorso-ventral height of the lungs were calculated. Mixed effects multi-linear regression and linear regression were used and significance was set at p<0.05. All horses demonstrated inspiratory breath holding until 5 hours after standing. No change from baseline was seen for the distribution of ventilation during inspiration. Filling time and inflation period were more rapid and shorter in ventral and slower and longer in most dorsal ROI compared to baseline, respectively. In a mixed effects multi-linear regression, breath holding was significantly correlated with PaCO2 in both the univariate and multivariate regression. Following recovery from anaesthesia, horses showed inspiratory breath holding during which gas redistributed from ventral into dorsal regions of the lungs. This suggests auto-recruitment of lung tissue which would have been dependent and likely atelectic during anaesthesia. PMID:27331910

  20. Methylxanthine reversal of opioid-evoked inspiratory depression via phosphodiesterase-4 blockade.

    PubMed

    Ruangkittisakul, Araya; Ballanyi, Klaus

    2010-07-31

    Hypothetic mechanisms for respirogenic methylxanthine actions include blockade of adenosine receptors or phosphodiesterase-4 (PDE4) in inspiratory pre-Bötzinger complex (preBötC) networks. Here, we studied this by analyzing stimulating caffeine and theophylline actions on mu-opioid-depressed inspiratory-related rhythm in the ventrolateral aspect of rat brainstem slices. The methylxanthines restored DAMGO (0.5-1 microM) depressed rhythm only at >1mM, which is approximately 10-fold higher than selective for adenosine receptors. Adenosine receptor blockers did neither counter DAMGO inhibition nor change control rhythm, similar to adenosine (0.1-2.5 mM). The specific PDE4 blocker rolipram (5 microM) restored DAMGO-depressed rhythm incompletely, but effectively reversed similar inhibition by clinical mu-agonist (fentanyl, 0.1 microM). At 0.25 microM, rolipram boosted incomplete recovery by 1 mM theophylline of DAMGO-depressed rhythm. Findings indicate that methylxanthines excite rhythmogenic preBötC networks via blockade of cAMP dependent PDE4 and suggest that specific PDE4 inhibitors (plus low methylxanthine doses) stimulate breathing effectively. We discuss why methylxanthine doses for preBötC stimulation need to be higher than those for respirogenic effects in vivo. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Nasal Drug Delivery in Traditional Persian Medicine

    PubMed Central

    Zarshenas, Mohammad Mehdi; Zargaran, Arman; Müller, Johannes; Mohagheghzadeh, Abdolali

    2013-01-01

    Background Over one hundred different pharmaceutical dosage forms have been recorded in literatures of Traditional Persian Medicine among which nasal forms are considerable. Objectives This study designed to derive the most often applied nasal dosage forms together with those brief clinical administrations. Materials and Methods In the current study remaining pharmaceutical manuscripts of Persia during 9th to 18th century AD have been studied and different dosage forms related to nasal application of herbal medicines and their therapeutic effects were derived. Results By searching through pharmaceutical manuscripts of medieval Persia, different nasal dosage forms involving eleven types related to three main groups are found. These types could be derived from powder, solution or liquid and gaseous forms. Gaseous form were classified into fumigation (Bakhoor), vapor bath (Enkebab), inhalation (Lakhlakheh), aroma agents (Ghalieh) and olfaction or smell (Shomoom). Nasal solutions were as drops (Ghatoor), nasal snuffing drops (Saoot) and liquid snuff formulations (Noshoogh). Powders were as nasal insufflation or snorting agents (Nofookh) and errhine or sternutator medicine (Otoos). Nasal forms were not applied only for local purposes. Rather systemic disorders and specially CNS complications were said to be a target for these dosage forms. Discussion While this novel type of drug delivery is known as a suitable substitute for oral and parenteral administration, it was well accepted and extensively mentioned in Persian medical and pharmaceutical manuscripts and other traditional systems of medicine as well. Accordingly, medieval pharmaceutical standpoints on nasal dosage forms could still be an interesting subject of study. Therefore, the current work can briefly show the pharmaceutical knowledge on nasal formulations in medieval Persia and clarify a part of history of traditional Persian pharmacy. PMID:24624204

  2. Impact of developing a multidisciplinary coded dataset standard on administrative data accuracy for septoplasty, septorhinoplasty and nasal trauma surgery.

    PubMed

    Nouraei, S A R; Hudovsky, A; Virk, J S; Saleh, H A

    2017-04-01

    This study aimed to develop a multidisciplinary coded dataset standard for nasal surgery and to assess its impact on data accuracy. An audit of 528 patients undergoing septal and/or inferior turbinate surgery, rhinoplasty and/or septorhinoplasty, and nasal fracture surgery was undertaken. A total of 200 septoplasties, 109 septorhinoplasties, 57 complex septorhinoplasties and 116 nasal fractures were analysed. There were 76 (14.4 per cent) changes to the primary diagnosis. Septorhinoplasties were the most commonly amended procedures. The overall audit-related income change for nasal surgery was £8.78 per patient. Use of a multidisciplinary coded dataset standard revealed that nasal diagnoses were under-coded; a significant proportion of patients received more precise diagnoses following the audit. There was also significant under-coding of both morbidities and revision surgery. The multidisciplinary coded dataset standard approach can improve the accuracy of both data capture and information flow, and, thus, ultimately create a more reliable dataset for use outcomes and health planning.

  3. Effects of particulate air pollution on nasal and lung function development among Greek children: a 19-year cohort study.

    PubMed

    Spyratos, Dionisios; Sioutas, Constantinos; Tsiotsios, Anastasios; Haidich, Anna-Bettina; Chloros, Diamantis; Triantafyllou, Georgios; Sichletidis, Lazaros

    2015-01-01

    The aim was to investigate respiratory symptoms, lung function and nasal airflow development among a cohort of children who were exposed to particulate air pollution. We used questionnaires, spirometry and rhinomanometry, while central-monitored PM10 concentrations were used for exposure assessment. We initially examined 1046 children (10-12 year old) in the heavily polluted town of Ptolemaida, Greece, and 379 children in the cleaner town of Grevena (control group). We re-evaluated 312 of the former and 119 of the latter after 19 years. PM10 concentrations were above permissible levels in Ptolemaida during all study period. At both visits, nasal flow was significantly lower in the study sample. At the follow-up visit, 34.3% had severe nasal obstruction (< 500 ml/s) and 38.5% reported chronic nasal symptoms. Spirometric parameters did not differ compared to the control group. Particulate air pollution had significant and negative effects on nasal but not on lung function development.

  4. Novel radiator for carbon dioxide absorbents in low-flow anesthesia.

    PubMed

    Hirabayashi, Go; Mitsui, Takanori; Kakinuma, Takayasu; Ogihara, Yukihiko; Matsumoto, Shohei; Isshiki, Atsushi; Yasuo, Watanabe

    2003-01-01

    During long-term low-flow sevoflurane anesthesia, dew formation and the generation of compound A are increased in the anesthesia circuit because of elevated soda lime temperature. The object of this study was to develop a novel radiator for carbon dioxide absorbents used for long durations of low-flow sevoflurane anesthesia. Eleven female swine were divided into two groups comprising a "radiator" group (n = 5) that used a novel radiator for carbon dioxide absorbents and a "control" group (n = 6) that used a conventional canister. Anesthesia was maintained with N2O, O2, and sevoflurane, and low-flow anesthesia was performed with fresh gas flow at 0.6 L/min for 12 hr. In the "control" group, the soda lime temperature reached more than 40 degrees C and soda lime dried up with severe dew formation in the inspiratory valve. In the "radiator" group, the temperature of soda lime stayed at 30 degrees C, and the water content of soda lime was retained with no dew formation in the inspiratory valve. In addition, compound A concentration was reduced. In conclusion, radiation of soda lime reduced the amounts of condensation formed and the concentration of compound A in the anesthetic circuit, and allowed long term low-flow anesthesia without equipment malfunction.

  5. Numerical simulation and nasal air-conditioning

    PubMed Central

    Keck, Tilman; Lindemann, Jörg

    2011-01-01

    Heating and humidification of the respiratory air are the main functions of the nasal airways in addition to cleansing and olfaction. Optimal nasal air conditioning is mandatory for an ideal pulmonary gas exchange in order to avoid desiccation and adhesion of the alveolar capillary bed. The complex three-dimensional anatomical structure of the nose makes it impossible to perform detailed in vivo studies on intranasal heating and humidification within the entire nasal airways applying various technical set-ups. The main problem of in vivo temperature and humidity measurements is a poor spatial and time resolution. Therefore, in vivo measurements are feasible only to a restricted extent, solely providing single temperature values as the complete nose is not entirely accessible. Therefore, data on the overall performance of the nose are only based on one single measurement within each nasal segment. In vivo measurements within the entire nose are not feasible. These serious technical issues concerning in vivo measurements led to a large number of numerical simulation projects in the last few years providing novel information about the complex functions of the nasal airways. In general, numerical simulations merely calculate predictions in a computational model, e.g. a realistic nose model, depending on the setting of the boundary conditions. Therefore, numerical simulations achieve only approximations of a possible real situation. The aim of this review is the synopsis of the technical expertise on the field of in vivo nasal air conditioning, the novel information of numerical simulations and the current state of knowledge on the influence of nasal and sinus surgery on nasal air conditioning. PMID:22073112

  6. A new approach to the treatment of nasal bone fracture: radiologic classification of nasal bone fractures and its clinical application.

    PubMed

    Han, Daniel Seung Youl; Han, Yea Sik; Park, Jin Hyung

    2011-11-01

    A radiologic examination is required in the treatment of nasal bone fracture to determine the fracture condition. Thus, there is an increasing need for radiologic classification of nasal bone fractures that can be applied to clinical practice. Computed tomography was performed in 125 patients with nasal bone fractures to determine which axial view best showed the entire nasal view. The obtained axial view was then used as a reference for classification. The length from the top to the base of the nasal bone was divided into upper, middle, and lower levels, after which the fracture location was determined. If the fracture spanned the boundaries of these levels, it was classified as the total level. Subsequently, the fracture was subclassified based on the fracture direction and pattern and the concurrent fracture. Radiologic examination of patients with nasal bone fracture showed that nasal bone fracture was frequently found at the total, middle, upper, and lower levels, in that order. Nasal bone fractures at the upper level showed lower frequencies of complication and reoperation than the fractures at the other levels, whereas nasal bone fractures at the total level showed the highest frequencies of complication and reoperation. Radiologic classification can be useful for preoperative and postoperative evaluations of nasal bone fractures and can be helpful in understanding such fractures because it can efficiently predict the prognosis of a fracture. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Clinical review: Humidifiers during non-invasive ventilation - key topics and practical implications

    PubMed Central

    2012-01-01

    Inadequate gas conditioning during non-invasive ventilation (NIV) can impair the anatomy and function of nasal mucosa. The resulting symptoms may have a negative effect on patients' adherence to ventilatory treatment, especially for chronic use. Several parameters, mostly technical aspects of NIV, contribute to inefficient gas conditioning. Factors affecting airway humidity during NIV include inspiratory flow, inspiratory oxygen fraction, leaks, type of ventilator, interface used to deliver NIV, temperature and pressure of inhaled gas, and type of humidifier. The correct application of a humidification system may avoid the effects of NIV-induced drying of the airway. This brief review analyses the consequences of airway dryness in patients receiving NIV and the technical tools necessary to guarantee adequate gas conditioning during ventilatory treatment. Open questions remain about the timing of gas conditioning for acute or chronic settings, the choice and type of humidification device, the interaction between the humidifier and the underlying disease, and the effects of individual humidification systems on delivered humidity. PMID:22316078

  8. Nasal and Oral Inspiration During Natural Speech Breathing

    PubMed Central

    Lester, Rosemary A.; Hoit, Jeannette D.

    2015-01-01

    Purpose The purpose of this study was to determine the typical pattern for inspiration during speech breathing in healthy adults, as well as the factors that might influence it. Method Ten healthy adults, 18–45 years of age, performed a variety of speaking tasks while nasal ram pressure, audio, and video recordings were obtained. Inspirations were categorized as a nasal only, oral only, simultaneous nasal and oral, or alternating nasal and oral inspiration. The method was validated using nasal airflow, oral airflow, audio, and video recordings for two participants. Results The predominant pattern was simultaneous nasal and oral inspirations for all speaking tasks. This pattern was not affected by the nature of the speaking task or by the phonetic context surrounding the inspiration. The validation procedure confirmed that nearly all inspirations during counting and paragraph reading were simultaneous nasal and oral inspirations; whereas for sentence reading, the predominant pattern was alternating nasal and oral inspirations across the three phonetic contexts. Conclusions Healthy adults inspire through both the nose and mouth during natural speech breathing. This pattern of inspiration is likely beneficial in reducing pathway resistance while preserving some of the benefits of nasal breathing. PMID:24129013

  9. Effect of inspiratory muscle training with load compared with sham training on blood pressure in individuals with hypertension: study protocol of a double-blind randomized clinical trial.

    PubMed

    Posser, Simone Regina; Callegaro, Carine Cristina; Beltrami-Moreira, Marina; Moreira, Leila Beltrami

    2016-08-02

    Hypertension is a complex chronic condition characterized by elevated arterial blood pressure. Management of hypertension includes non-pharmacologic strategies, which may include techniques that effectively reduce autonomic sympathetic activity. Respiratory exercises improve autonomic control over cardiovascular system and attenuate muscle metaboreflex. Because of these effects, respiratory exercises may be useful to lower blood pressure in subjects with hypertension. This randomized, double-blind clinical trial will test the efficacy of inspiratory muscle training in reducing blood pressure in adults with essential hypertension. Subjects are randomly allocated to intervention or control groups. Intervention consists of inspiratory muscle training loaded with 40 % of maximum inspiratory pressure, readjusted weekly. Control sham intervention consists of unloaded exercises. Systolic and diastolic blood pressures are co-primary endpoint measures assessed with 24 h ambulatory blood pressure monitoring. Secondary outcome measures include cardiovascular autonomic control, inspiratory muscle metaboreflex, cardiopulmonary capacity, and inspiratory muscle strength and endurance. Previously published work suggests that inspiratory muscle training reduces blood pressure in persons with hypertension, but the effectiveness of this intervention is yet to be established. We propose an adequately sized randomized clinical trial to test this hypothesis rigorously. If an effect is found, this study will allow for the investigation of putative mechanisms to mediate this effect, including autonomic cardiovascular control and metaboreflex. ClinicalTrials.gov NCT02275377 . Registered on 30 September 2014.

  10. Impacts of Fluid Dynamics Simulation in Study of Nasal Airflow Physiology and Pathophysiology in Realistic Human Three-Dimensional Nose Models

    PubMed Central

    Lee, Heow Peuh; Gordon, Bruce R.

    2012-01-01

    During the past decades, numerous computational fluid dynamics (CFD) studies, constructed from CT or MRI images, have simulated human nasal models. As compared to rhinomanometry and acoustic rhinometry, which provide quantitative information only of nasal airflow, resistance, and cross sectional areas, CFD enables additional measurements of airflow passing through the nasal cavity that help visualize the physiologic impact of alterations in intranasal structures. Therefore, it becomes possible to quantitatively measure, and visually appreciate, the airflow pattern (laminar or turbulent), velocity, pressure, wall shear stress, particle deposition, and temperature changes at different flow rates, in different parts of the nasal cavity. The effects of both existing anatomical factors, as well as post-operative changes, can be assessed. With recent improvements in CFD technology and computing power, there is a promising future for CFD to become a useful tool in planning, predicting, and evaluating outcomes of nasal surgery. This review discusses the possibilities and potential impacts, as well as technical limitations, of using CFD simulation to better understand nasal airflow physiology. PMID:23205221

  11. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and

  12. Phenotype and function of nasal dendritic cells

    PubMed Central

    Lee, Haekyung; Ruane, Darren; Law, Kenneth; Ho, Yan; Garg, Aakash; Rahman, Adeeb; Esterházy, Daria; Cheong, Cheolho; Goljo, Erden; Sikora, Andrew G.; Mucida, Daniel; Chen, Benjamin; Govindraj, Satish; Breton, Gaëlle; Mehandru, Saurabh

    2015-01-01

    Intranasal vaccination generates immunity across local, regional and distant sites. However, nasal dendritic cells (DC), pivotal for the induction of intranasal vaccine- induced immune responses, have not been studied in detail. Here, using a variety of parameters, we define nasal DCs in mice and humans. Distinct subsets of “classical” DCs, dependent on the transcription factor zbtb46 were identified in the murine nose. The murine nasal DCs were FLT3 ligand-responsive and displayed unique phenotypic and functional characteristics including the ability to present antigen, induce an allogeneic T cell response and migrate in response to LPS or live bacterial pathogens. Importantly, in a cohort of human volunteers, BDCA-1+ DCs were observed to be the dominant nasal DC population at steady state. During chronic inflammation, the frequency of both BDCA-1+ and BDCA-3hi DCs was reduced in the nasal tissue, associating the loss of these immune sentinels with chronic nasal inflammation. The present study is the first detailed description of the phenotypic, ontogenetic and functional properties of nasal DCs and will inform the design of preventative immunization strategies as well as therapeutic modalities against chronic rhinosinusitis. PMID:25669151

  13. Regional deposition of mometasone furoate nasal spray suspension in humans.

    PubMed

    Shah, Samir A; Berger, Robert L; McDermott, John; Gupta, Pranav; Monteith, David; Connor, Alyson; Lin, Wu

    2015-01-01

    Nasal deposition studies can demonstrate whether nasal sprays treating allergic rhinitis and polyposis reach the ciliated posterior nasal cavity, where turbinate inflammation and other pathology occurs. However, quantifying nasal deposition is challenging, because in vitro tests do not correlate to human nasal deposition; gamma scintigraphy studies are thus used. For valid data, the radiolabel must distribute, as the drug, into different-sized droplets, remain associated with the drug in the formulation after administration, and not alter its deposition. Some nasal deposition studies have demonstrated this using homogenous solutions. However, most commercial nasal sprays are heterogeneous suspensions. Using mometasone furoate nasal suspension (MFS), we developed a technique to validate radiolabel deposition as a surrogate for nasal cavity drug deposition and characterized regional deposition and nasal clearance in humans. Mometasone furoate (MF) formulation was spiked with diethylene triamine pentacaetic acid. Both unlabeled and radiolabeled formulations (n = 3) were sprayed into a regionally divided nasal cast. Drug deposition was quantified by high pressure liquid chromatography within each region; radiolabel deposition was determined by gamma camera. Healthy subjects (n = 12) were dosed and imaged for six hours. Scintigraphic images were coregistered with magnetic resonance imaging scans to quantify anterior and posterior nasal cavity deposition and mucociliary clearance. The ratio of radiolabel to unlabeled drug was 1.05 in the nasal cast and regionally appeared to match, indicating that in vivo radiolabel deposition could represent drug deposition. In humans, MFS delivered 86% (9.2) of metered dose to the nasal cavity, approximately 60% (9.1) of metered dose to the posterior nasal cavity. After 15 minutes, mucociliary clearance removed 59% of the initial radiolabel in the nasal cavity, consistent with clearance rates from the ciliated posterior surface. MFS

  14. Regional deposition of mometasone furoate nasal spray suspension in humans.

    PubMed

    Shah, S A; Berger, R L; McDermott, J; Gupta, P; Monteith, D; Connor, A; Lin, W

    2014-11-21

    Nasal deposition studies can demonstrate whether nasal sprays treating allergic rhinitis and polyposis reach the ciliated posterior nasal cavity, where turbinate inflammation and other pathology occurs. However, quantifying nasal deposition is challenging, because in vitro tests do not correlate to human nasal deposition; gamma scintigraphy studies are thus used. For valid data, the radiolabel must distribute, as the drug, into different-sized droplets, remain associated with the drug in the formulation after administration, and not alter its deposition. Some nasal deposition studies have demonstrated this using homogenous solutions. However, most commercial nasal sprays are heterogeneous suspensions. Using mometasone furoate nasal suspension (MFS), we developed a technique to validate radiolabel deposition as a surrogate for nasal cavity drug deposition and characterized regional deposition and nasal clearance in humans. Mometasone furoate (MF) formulation was spiked with diethylene triamine pentacaetic acid. Both unlabeled and radiolabeled formulations (n = 3) were sprayed into a regionally divided nasal cast. Drug deposition was quantified by high pressure liquid chromatography within each region; radiolabel deposition was determined by gamma camera. Healthy subjects (n = 12) were dosed and imaged for six hours. Scintigraphic images were coregistered with magnetic resonance imaging scans to quantify anterior and posterior nasal cavity deposition and mucociliary clearance. The ratio of radiolabel to unlabeled drug was 1.05 in the nasal cast and regionally appeared to match, indicating that in vivo radiolabel deposition could represent drug deposition. In humans, MFS delivered 86% (9.2) of metered dose to the nasal cavity, approximately 60% (9.1) of metered dose to the posterior nasal cavity. After 15 minutes, mucociliary clearance removed 59% of the initial radiolabel in the nasal cavity, consistent with clearance rates from the ciliated posterior surface. MFS

  15. A Cost-Effectiveness Analysis of Nasal Surgery to Increase Continuous Positive Airway Pressure Adherence in Sleep Apnea Patients With Nasal Obstruction

    PubMed Central

    Kempfle, Judith S.; BuSaba, Nicholas Y.; Dobrowski, John M.; Westover, Michael B.; Bianchi, Matt T.

    2017-01-01

    Objectives/Hypothesis Nasal surgery has been implicated to improve continuous positive airway pressure (CPAP) compliance in patients with obstructive sleep apnea (OSA) and nasal obstruction. However, the cost-effectiveness of nasal surgery to improve CPAP compliance is not known. We modeled the cost-effectiveness of two types of nasal surgery versus no surgery in patients with OSA and nasal obstruction undergoing CPAP therapy. Study Design Cost-effectiveness decision tree model. Methods We built a decision tree model to identify conditions under which nasal surgery would be cost-effective to improve CPAP adherence over the standard of care. We compared turbinate reduction and septoplasty to nonsurgical treatment over varied time horizons from a third-party payer perspective. We included variables for cost of untreated OSA, surgical cost and complications, improved compliance postoperatively, and quality of life. Results Our study identified nasal surgery as a cost-effective strategy to improve compliance of OSA patients using CPAP across a range of plausible model assumptions regarding the cost of untreated OSA, the probability of adherence improvement, and a chronic time horizon. The relatively lower surgical cost of turbinate reduction made it more cost-effective at earlier time horizons, whereas septoplasty became cost-effective after a longer timespan. Conclusions Across a range of plausible values in a clinically relevant decision model, nasal surgery is a cost-effective strategy to improve CPAP compliance in OSA patients with nasal obstruction. Our results suggest that OSA patients with nasal obstruction who struggle with CPAP therapy compliance should undergo evaluation for nasal surgery. PMID:27653626

  16. Nasal Chondromesenchymal Hamartoma in a Child

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finitsis, Stefanos; Giavroglou, Constantinos; Potsi, Stamatia, E-mail: matinapotsi@hotmail.co

    Nasal chondromesenchymal hamartoma (NCMH) is a benign tumor that was described in 1998. The occurrence of this lesion in the nasal cavity of infants and children is especially rare, with only 21 cases reported in the international literature. We report a 12-month-old boy with respiratory distress due to nasal obstruction. Computed tomographic scan and magnetic resonance imaging examination demonstrated a soft-tissue mass obstructing the left nasal cavity. Digital subtraction angiography and preoperative superselective embolization with microparticles were also performed. The tumor was completely resected surgically. Histopathology and immunohistochemical analyses of the tumor disclosed a NCMH. The imaging characteristics of themore » tumor are described and the radiology literature is reviewed.« less

  17. Assessment of the effect of deviated nasal septum on the structure of nasal cavity.

    PubMed

    Wang, Junguo; Dou, Xin; Liu, Dingding; Song, Panpan; Qian, Xiaoyun; Wang, Shoulin; Gao, Xia

    2016-06-01

    The present study was aimed to investigate the effects of DNS on the structure of nasal cavity. The paranasal sinus coronal view CT of 108 patients with DNS and 129 hospitalized patients without DNS was retrospectively analyzed. The transverse diameter of nasal cavity (a), transverse diameter of nasal cavity and paranasal sinus (b), angle between maxillary and palatal bone, interalveolar distance, and maxillary rotation distance were measured. The ratio of a/b in experimental group was 0.367 ± 0.006 which was significantly (P = 0.0023) less than that in control group (0.391 ± 0.005). For the angle between maxillary and palatal bone, there was no significant difference found between DNS and control group for both right and left sides. The interalveolar distance was 40.75 mm in experimental group, and 38.8 mm in control (P = 0.0002). For the maxillary rotation distance, findings were considered as significant (P < 0.0001) in experimental group (11.25 mm) compared with control (10.1 mm). The present study demonstrates that long-term DNS affects the development of nasal cavity and paranasal sinus, as well as increases the interalveolar distance and maxillary rotation distance. These influences may be caused by the alteration of airflow inside the nasal cavities.

  18. Nasal high-frequency oscillatory ventilation impairs heated humidification: A neonatal bench study.

    PubMed

    Ullrich, Tim L; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik S

    2017-11-01

    Nasal high-frequency oscillatory ventilation (nHFOV) is a novel mode of non-invasive ventilation used in neonates. However, upper airway obstructions due to viscous secretions have been described as specific adverse effects. We hypothesized that high-frequency oscillations reduce air humidity in the oropharynx, resulting in upper airway desiccation. Therefore, we aimed to investigate the effects of nHFOV ventilatory settings on oropharyngeal gas conditions. NHFOV or nasal continuous positive airway pressure (nCPAP) was applied, along with heated humidification, to a previously established neonatal bench model that simulates oropharyngeal gas conditions during spontaneous breathing through an open mouth. A digital thermo-hygro sensor measured oropharyngeal temperature (T) and humidity at various nHFOV frequencies (7, 10, 13 Hz), amplitudes (10, 20, 30 cmH 2 O), and inspiratory-to-expiratory (I:E) ratios (25:75, 33:66, 50:50), and also during nCPAP. Relative humidity was always >99%, but nHFOV resulted in lower mean T and absolute humidity (AH) in comparison to nCPAP (P < 0.001). Specifically, decreasing the nHFOV frequency and increasing nHFOV amplitude caused a decline in T and AH (P < 0.001). Mean T and AH were highest during nCPAP (T 34.8 ± 0.6°C, AH 39.3 ± 1.3 g · m -3 ) and lowest during nHFOV at a frequency of 7 Hz and an amplitude of 30 cmH 2 O (T 32.4 ± 0.3°C, AH 34.7 ± 0.5 g · m -3 ). Increasing the I:E ratio also reduced T and AH (P = 0.03). Intensified nHFOV settings with low frequencies, high amplitudes, and high I:E ratios may place infants at an increased risk of upper airway desiccation. Future studies should investigate strategies to optimize heated humidification during nHFOV. © 2017 Wiley Periodicals, Inc.

  19. Distinguishing rhinitis and nasal neoplasia by radiography.

    PubMed

    Russo, M; Lamb, C R; Jakovljevic, S

    2000-01-01

    To compare the incidence of radiographic signs in dogs with rhinitis and primary nasal neoplasia and to assess the performance of observers for distinguishing these conditions, the nasal radiographs of 72 dogs with either rhinitis (n = 42) or primary nasal neoplasia (n = 30) were examined by two independent observers using custom-designed forms to record their interpretations. Rhinitis was associated with a higher incidence of focal or multifocal lesions, localised soft tissue opacities, lucent foci, and a lack of frontal sinus involvement. Neoplasia was associated with soft tissue opacities and loss of turbinate detail that affected the entire ipsilateral nasal cavity, signs of invasion of the bones surrounding the nasal cavity, and soft tissue/fluid opacities within the ipsilateral frontal sinus. The signs with the highest positive predictive value (PPV) for rhinitis were absence of frontal sinus lesions and lucent foci in nasal cavity (PPV of each 82%), and invasion of surrounding bones for neoplasia (PPV 88%). There were no significant differences in the position of the lesion within the nasal cavity, incidence of unilateral versus bilateral lesions, calcified lesions, or absence of teeth. There was moderate agreement between observers about the diagnosis (kappa 0.59). Areas (SE) under ROC curves were 0.94 (0.03) and 0.96 (0.03) for observers A and B, respectively (not significantly different; P = 0.68). These results indicate a high accuracy for radiologists examining dogs with nasal diseases. Differentiation of rhinitis and nasal neoplasia should be based on finding combinations of radiologic signs that together have a high PPV. Differences in interpretation between experienced observers in this study suggest that certain signs are potential sources of error.

  20. [Usage of polyvinylpyrrolidonic films for nasal cavity tamponade].

    PubMed

    Kriukov, A I; Karel'skaia, N A; Kleshnin, D A; Pashkin, I I

    2006-01-01

    The experience in otorhinolaryngological application of hydrogel films for nasal tamponade in nasal hemorrhage after surgical interventions on the intranasal structures and in nasal hemorrhage in leukemia patients was analysed.

  1. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  2. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  3. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  4. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  5. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  6. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  7. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  8. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  9. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  10. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  11. Influence of the respiratory cycle structure on the flow field in human nasal cavity at a fixed level of breath depth

    NASA Astrophysics Data System (ADS)

    Bosykh, L. Yu.; Ganimedov, V. L.; Muchnaya, M. I.; Sadovskii, A. S.

    2016-10-01

    The evolution of air flow field in the human nasal cavity has studied during the respiratory cycle. Real tomographic scans of the adult without abnormalities in the upper airway have been used to construct the geometric model. Quiet breathing mode is selected: the duration of the respiratory cycle is 4.3 sec and the depth of breathing is 600 ml, which provides pulmonary ventilation at 8.4 liters of air per minute. The system of Navier - Stokes equations was used to describe the flow. Laminar flow regime was postulated. The Lagrange approach was used for calculation of submicron particles motion. The numerical solution was built on the basis of gas-dynamic solver FLUENT of software package ANSYS 12. Calculations were made for two cases in which the same value of the integral characteristic (the depth of breathing) was reached, but which had different kind of boundary conditions on the exit. In the first case, the velocity was assumed symmetrical with respect to inhalation - exhalation and was approximated by sinusoid. In the second case, the velocity as a function of time is determined by processing of the real person spirogram. For the both variants the flow fields were obtained and compared. Analysis of the results showed that in non-stationary case the use of symmetric boundary condition leads to an underestimation of respiratory effort for the implementation of the required depth of breathing. In cyclic flow the flow fields in acceleration and deceleration phases are, basically, the same as in the corresponding steady flow. At the same time taking into account of non-symmetry of respiratory cycle influences on deposition pattern of particles significantly.

  12. A review of nasal polyposis

    PubMed Central

    Newton, Jonathan Ray; Ah-See, Kim Wong

    2008-01-01

    Nasal polyps are common, affecting up to four percent of the population. Their etiology remains unclear, but they are known to have associations with allergy, asthma, infection, cystic fibrosis, and aspirin sensitivity. They present with nasal obstruction, anosmia, rhinorrhoea, post nasal drip, and less commonly facial pain. Clinical examination reveals single or multiple grey polypoid masses in the nasal cavity. Computerized tomography allows evaluation of the extent of the disease and is essential if surgical treatment is to be considered. Management of polyposis involves a combination of medical therapy and surgery. There is good evidence for the use of corticosteroids (systemic and topical) both as primary treatment and as postoperative prophylaxis against recurrence. Surgical treatment has been refined significantly over the past twenty years with the advent of endoscopic sinus surgery and, in general, is reserved for cases refractory to medical treatment. Recurrence of the polyposis is common with severe disease recurring in up to ten percent of patients. PMID:18728843

  13. Normal and variant anatomy of the nasal tip.

    PubMed

    Ketcham, Amy S; Dobratz, Eric J

    2012-04-01

    A thorough understanding of nasal tip anatomy is a prerequisite to understanding the nuances of restructuring the nasal tip. The three-dimensional structural anatomy of the nasal tip is complex. Additionally, the interrelationship between these structures determines the ultimate form and function of the nasal tip. As a result, alteration of one structure in the tip will often lead to change in other portions of the nasal tip. This dynamic concept of anatomy in the nasal tip makes proper alteration of the nasal tip one of the most challenging tasks faced by a rhinoplasty surgeon. This article provides a fundamental knowledge of the normal anatomy of the tip structures and how their interaction with each other determines the shape and support of the lower portion of the nose. It also provides a description of some common variants of tip anatomy that cause patients to seek consultation for rhinoplasty. A proper understanding of the concepts presented provides a foundation to build on as the reader continues to explore the "nuances of the nasal tip." Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Tolerance to external breathing resistance with particular reference to high inspiratory resistance

    NASA Technical Reports Server (NTRS)

    Bentley, R. A.; Griffin, O. G.; Love, R. G.; Muir, D. C. F.; Sweetland, K. F.

    1972-01-01

    The ability of men to exercise while breathing through graded inspiratory resistances was studied in order to define acceptable respiratory mouthpiece assembly standards. Experimental results with subjects wearing breathing masks and walking for 30 min on treadmills were used to calculate expiratory work rates. It is concluded that the airflow must be appropriate to the upper limit of minute ventilation likely to be encountered in the men wearing the apparatus.

  15. Normative Nasalance Scores for Brazilian Portuguese Using New Speech Stimuli.

    PubMed

    Marino, Viviane Cristina de Castro; Dutka, Jeniffer de Cássia Rillo; de Boer, Gillian; Cardoso, Vanessa Moraes; Ramos, Renata Giorgetto; Bressmann, Tim

    2015-01-01

    Normative data were established for newly developed speech materials for nasalance assessment in Brazilian Portuguese. Nasalance scores of preexisting passages (oral ZOO-BR, low-pressure oral ZOO-BR2 and NASAL-BR), new nasalance passages (oral Dudu no zoológico, oral Dudu no bosque, oral-nasal O cãozinho Totó and nasal O nenê) and Brasilcleft articulation screening sentences were collected from 245 speakers of Brazilian Portuguese, including 121 males and 124 females, divided into 4 groups: children (5-9 years), adolescents (10-19 years), young adults (20-24 years) and adults (25-35 years). Across all nasalance passages, adult females scored on average 2 percentage points higher than males. Children scored 2-4 percentage points lower than older groups for the preexisting nasalance passages ZOO-BR and ZOO-BR2. Nasalance scores for the new nasalance passages were not significantly different from the preexisting passages. Scores for high-pressure sentences did not differ significantly from the oral nasalance passage Dudu no bosque. The nasalance scores for the new nasalance passages were equivalent to the preexisting materials. The new shortened and simplified nasalance passages will be useful for assessing young children. Normative scores for the Brasilcleft high-pressure sentences were equivalent to the new oral passage Dudu no bosque. © 2016 S. Karger AG, Basel.

  16. Acoustic Analysis of Nasal Vowels in Monguor Language

    NASA Astrophysics Data System (ADS)

    Zhang, Hanbin

    2017-09-01

    The purpose of the study is to analyze the spectrum characteristics and acoustic features for the nasal vowels [ɑ˜] and [ɔ˜] in Monguor language. On the base of acoustic parameter database of the Monguor speech, the study finds out that there are five main zero-pole pairs appearing for the nasal vowel [ɔ˜] and two zero-pole pairs appear for the nasal vowel [ɔ˜]. The results of regression analysis demonstrate that the duration of the nasal vowel [ɔ˜] or the nasal vowel [ɔ˜] can be predicted by its F1, F2 and F3 respectively.

  17. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

    PubMed

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S

    2016-09-15

    Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  18. Impact of a Behavioral-Based Intervention on Inspiratory Muscle Training Prescription by a Multidisciplinary Team

    ERIC Educational Resources Information Center

    Simms, Alanna M.; Li, Linda C.; Geddes, E. Lynne; Brooks, Dina; Hoens, Alison M.; Reid, W. Darlene

    2012-01-01

    Introduction: Our goal was to compare behavioral- and information-based interventions aimed at increasing prescription of inspiratory muscle training (IMT) for people with chronic obstructive pulmonary disease (COPD) by interdisciplinary teams during pulmonary rehabilitation (PR). Methods: Six hospital PR programs were randomly assigned to a…

  19. Diagnostic and Therapeutic Management of Nasal Airway Obstruction: Advances in Diagnosis and Treatment.

    PubMed

    Mohan, Suresh; Fuller, Jennifer C; Ford, Stephanie Friree; Lindsay, Robin W

    2018-05-10

    Nasal airway obstruction (NAO) is a common complaint in the otolaryngologist's office and can have a negative influence on quality of life (QOL). Existing diagnostic methods have improved, but little consensus exists on optimal tools. Furthermore, although surgical techniques for nasal obstruction continue to be developed, effective outcome measurement is lacking. An update of recent advances in diagnostic and therapeutic management of NAO is warranted. To review advances in diagnosis and treatment of NAO from the last 5 years. PubMed, Embase, CINAHL, the Cochrane Library, LILACS, Web of Science, and Guideline.gov were searched with the terms nasal obstruction and nasal blockage and their permutations from July 26, 2012, through October 23, 2017. Studies were included if they evaluated NAO using a subjective and an objective technique, and in the case of intervention-based studies, the Nasal Obstruction Symptom Evaluation (NOSE) scale and an objective technique. Exclusion criteria consisted of animal studies; patients younger than 14 years; nasal foreign bodies; nasal masses including polyps; choanal atresia; sinus disease; obstructive sleep apnea or sleep-disordered breathing; allergic rhinitis; and studies not specific to nasal obstruction. The initial search resulted in 942 articles. After independent screening by 2 investigators, 46 unique articles remained, including 2 randomized clinical trials, 3 systematic reviews, 3 meta-analyses, and 39 nonrandomized cohort studies (including a combined systematic review and meta-analysis). An aggregate of approximately 32 000 patients were reviewed (including meta-analyses). Of the subjective measures available for NAO, the NOSE scale is outstanding with regard to disease-specific validation and correlation with symptoms. No currently available objective measure can be considered a criterion standard. Structural measures of flow, pressure, and volume appear to be necessary but insufficient to assess NAO. Therefore

  20. Nasal Base Retraction: A Treatment Algorithm.

    PubMed

    Tas, Süleyman; Colakoglu, Salih; Lee, Bernard Travis

    2017-06-01

    Nasal base retraction results from cephalic malposition of the alar base in the vertical plane, which causes disharmony of the alar base with the rest of the nose structures. Correcting nasal base retraction is very important for improved aesthetic outcomes; however, there is a limited body of literature about this deformity and its treatment. Create a nasal base retraction treatment algorithm based on a severity classification system. This is a retrospective case review study of 53 patients who underwent rhinoplasty with correction of alar base retraction by the senior author (S.T.). The minimum follow-up time was 6 months. Levator labii alaque nasi muscle dissection or alar base release with or without a rim graft on the effected side were performed based on the severity of the alar base retraction. Aesthetic results were assessed with objective grading of preoperative and postoperative patient photographs by two independent plastic surgeons. Functional improvement was assessed with patient self-evaluations of nasal patency. Also, a rhinoplasty outcomes evaluation (ROE) questionnaire was distributed to patients. Comparison of preoperative and postoperative photographs demonstrated that nasal base asymmetry was significantly improved in all cases, and 85% of the patients had complete symmetry. Nasal obstruction was also significantly reduced after surgery (P < 0.001). The majority of patients reported satisfaction (92.5%), with an ROE total score greater than or equal to 20. New techniques and a treatment algorithm for correcting nasal base retraction deformities that will help rhinoplasty surgeons obtain aesthetically and functionally pleasing outcomes for patients. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  1. High flow nasal cannula (HFNC) versus nasal continuous positive airway pressure (nCPAP) for the initial respiratory management of acute viral bronchiolitis in young infants: a multicenter randomized controlled trial (TRAMONTANE study).

    PubMed

    Milési, Christophe; Essouri, Sandrine; Pouyau, Robin; Liet, Jean-Michel; Afanetti, Mickael; Portefaix, Aurélie; Baleine, Julien; Durand, Sabine; Combes, Clémentine; Douillard, Aymeric; Cambonie, Gilles

    2017-02-01

    Nasal continuous positive airway pressure (nCPAP) is currently the gold standard for respiratory support for moderate to severe acute viral bronchiolitis (AVB). Although oxygen delivery via high flow nasal cannula (HFNC) is increasingly used, evidence of its efficacy and safety is lacking in infants. A randomized controlled trial was performed in five pediatric intensive care units (PICUs) to compare 7 cmH 2 O nCPAP with 2 L/kg/min oxygen therapy administered with HFNC in infants up to 6 months old with moderate to severe AVB. The primary endpoint was the percentage of failure within 24 h of randomization using prespecified criteria. To satisfy noninferiority, the failure rate of HFNC had to lie within 15% of the failure rate of nCPAP. Secondary outcomes included success rate after crossover, intubation rate, length of stay, and serious adverse events. From November 2014 to March 2015, 142 infants were included and equally distributed into groups. The risk difference of -19% (95% CI -35 to -3%) did not allow the conclusion of HFNC noninferiority (p = 0.707). Superiority analysis suggested a relative risk of success 1.63 (95% CI 1.02-2.63) higher with nCPAP. The success rate with the alternative respiratory support, intubation rate, durations of noninvasive and invasive ventilation, skin lesions, and length of PICU stay were comparable between groups. No patient had air leak syndrome or died. In young infants with moderate to severe AVB, initial management with HFNC did not have a failure rate similar to that of nCPAP. This clinical trial was recorded in the National Library of Medicine registry (NCT 02457013).

  2. Effects of nasal drug delivery device and its orientation on sprayed particle deposition in a realistic human nasal cavity.

    PubMed

    Tong, Xuwen; Dong, Jingliang; Shang, Yidan; Inthavong, Kiao; Tu, Jiyuan

    2016-10-01

    In this study, the effects of nasal drug delivery device and the spray nozzle orientation on sprayed droplets deposition in a realistic human nasal cavity were numerically studied. Prior to performing the numerical investigation, an in-house designed automated actuation system representing mean adults actuation force was developed to produce realistic spray plume. Then, the spray plume development was filmed by high speed photography system, and spray characteristics such as spray cone angle, break-up length, and average droplet velocity were obtained through off-line image analysis. Continuing studies utilizing those experimental data as boundary conditions were applied in the following numerical spray simulations using a commercially available nasal spray device, which was inserted into a realistic adult nasal passage with external facial features. Through varying the particle releasing direction, the deposition fractions of selected particle sizes on the main nasal passage for targeted drug delivery were compared. The results demonstrated that the middle spray direction showed superior spray efficiency compared with upper or lower directions, and the 10µm agents were the most suitable particle size as the majority of sprayed agents can be delivered to the targeted area, the main passage. This study elaborates a comprehensive approach to better understand nasal spray mechanism and evaluate its performance for existing nasal delivery practices. Results of this study can assist the pharmaceutical industry to improve the current design of nasal drug delivery device and ultimately benefit more patients through optimized medications delivery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Nasal high-flow therapy reduces work of breathing compared with oxygen during sleep in COPD and smoking controls: a prospective observational study

    PubMed Central

    Kirkness, Jason P.; Grote, Ludger; Fricke, Kathrin; Schwartz, Alan R.; Smith, Philip; Schneider, Hartmut

    2017-01-01

    Patients with chronic obstructive pulmonary disease (COPD) endure excessive resistive and elastic loads leading to chronic respiratory failure. Oxygen supplementation corrects hypoxemia but is not expected to reduce mechanical loads. Nasal high-flow (NHF) therapy supports breathing by reducing dead space, but it is unclear how it affects mechanical loads of patients with COPD. The objective of this study was to compare the effects of low-flow oxygen and NHF therapy on ventilation and work of breathing (WOB) in patients with COPD and controls during sleep. Patients with COPD (n = 12) and controls (n = 6) were recruited and submitted to polysomnography to measure sleep parameters and ventilation in response to administration of oxygen and NHF. A subset of six patients also had an esophageal catheter inserted for the purpose of measuring WOB. Patients with COPD had similar minute ventilation (V̇e) but lower tidal volumes than matched controls. With oxygen, SaO2was increased and V̇e was reduced in both controls and patients with COPD, but there was an increase in transcutaneous CO2 levels. NHF produced a greater reduction in V̇e and was associated with a reduction in CO2 levels. Although NHF halved WOB, oxygen produced only a minor reduction in this parameter. We conclude that oxygen produced little change in WOB, which was associated with CO2 elevations. On the other hand, NHF produced a large reduction in V̇e and WOB with a concomitant decrease in CO2 levels. Our data indicate that NHF improves alveolar ventilation during sleep compared with oxygen and room air in patients with COPD and therefore can decrease their cost of breathing. NEW & NOTEWORTHY Nasal high-flow (NHF) therapy can support ventilation in patients with chronic obstructive pulmonary disease during sleep by decreasing the work of breathing and improving CO2 levels. On the other hand, oxygen supplementation corrects hypoxemia, but it produces only a minimal reduction in work of breathing and is

  4. Comparison of the effectiveness of high flow nasal oxygen cannula vs. standard non-rebreather oxygen face mask in post-extubation intensive care unit patients.

    PubMed

    Brotfain, Evgeni; Zlotnik, Alexander; Schwartz, Andrei; Frenkel, Amit; Koyfman, Leonid; Gruenbaum, Shaun E; Klein, Moti

    2014-11-01

    Optimal oxygen supply is the cornerstone of the management of critically ill patients after extubation, especially in patients at high risk for extubation failure. In recent years, high flow oxygen system devices have offered an appropriate alternative to standard oxygen therapy devices such as conventional face masks and nasal prongs. To assess the clinical effects of high flow nasal cannula (HFNC) compared with standard oxygen face masks in Intensive Care Unit (ICU) patients after extubation. We retrospectively analyzed 67 consecutive ventilated critical care patients in the ICU over a period of 1 year. The patients were allocated to two treatment groups: HFNC (34 patients, group 1) and non-rebreathing oxygen face mask (NRB) (33 patients, group 2). Vital respiratory and hemodynamic parameters were assessed prior to extubation and 6 hours after extubation. The primary clinical outcomes measured were improvement in oxygenation, ventilation-free days, re-intubation, ICU length of stay, and mortality. The two groups demonstrated similar hemodynamic patterns before and after extubation. The respiratory rate was slightly elevated in both groups after extubation with no differences observed between groups. There were no statistically significant clinical differences in PaCO2. However, the use of HFNC resulted in improved PaO2/FiO2 post-extubation (P < 0.05). There were more ventilator-free days in the HFNC group (P< 0.05) and fewer patients required reintubation (1 vs. 6). There were no differences in ICU length of stay or mortality. This study demonstrated better oxygenation for patients treated with HFNC compared with NRB after extubation. HFNC may be more effective than standard oxygen supply devices for oxygenation in the post-extubation period.

  5. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    PubMed

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  6. High-flow oxygen therapy: pressure analysis in a pediatric airway model.

    PubMed

    Urbano, Javier; del Castillo, Jimena; López-Herce, Jesús; Gallardo, José A; Solana, María J; Carrillo, Ángel

    2012-05-01

    The mechanism of high-flow oxygen therapy and the pressures reached in the airway have not been defined. We hypothesized that the flow would generate a low continuous positive pressure, and that elevated flow rates in this model could produce moderate pressures. The objective of this study was to analyze the pressure generated by a high-flow oxygen therapy system in an experimental model of the pediatric airway. An experimental in vitro study was performed. A high-flow oxygen therapy system was connected to 3 types of interface (nasal cannulae, nasal mask, and oronasal mask) and applied to 2 types of pediatric manikin (infant and neonatal). The pressures generated in the circuit, in the airway, and in the pharynx were measured at different flow rates (5, 10, 15, and 20 L/min). The experiment was conducted with and without a leak (mouth sealed and unsealed). Linear regression analyses were performed for each set of measurements. The pressures generated with the different interfaces were very similar. The maximum pressure recorded was 4 cm H(2)O with a flow of 20 L/min via nasal cannulae or nasal mask. When the mouth of the manikin was held open, the pressures reached in the airway and pharynxes were undetectable. Linear regression analyses showed a similar linear relationship between flow and pressures measured in the pharynx (pressure = -0.375 + 0.138 × flow) and in the airway (pressure = -0.375 + 0.158 × flow) with the closed mouth condition. According to our hypothesis, high-flow oxygen therapy systems produced a low-level CPAP in an experimental pediatric model, even with the use of very high flow rates. Linear regression analyses showed similar linear relationships between flow and pressures measured in the pharynx and in the airway. This finding suggests that, at least in part, the effects may be due to other mechanisms.

  7. Increasing the inspiratory time and I:E ratio during mechanical ventilation aggravates ventilator-induced lung injury in mice.

    PubMed

    Müller-Redetzky, Holger C; Felten, Matthias; Hellwig, Katharina; Wienhold, Sandra-Maria; Naujoks, Jan; Opitz, Bastian; Kershaw, Olivia; Gruber, Achim D; Suttorp, Norbert; Witzenrath, Martin

    2015-01-28

    Lung-protective ventilation reduced acute respiratory distress syndrome (ARDS) mortality. To minimize ventilator-induced lung injury (VILI), tidal volume is limited, high plateau pressures are avoided, and positive end-expiratory pressure (PEEP) is applied. However, the impact of specific ventilatory patterns on VILI is not well defined. Increasing inspiratory time and thereby the inspiratory/expiratory ratio (I:E ratio) may improve oxygenation, but may also be harmful as the absolute stress and strain over time increase. We thus hypothesized that increasing inspiratory time and I:E ratio aggravates VILI. VILI was induced in mice by high tidal-volume ventilation (HVT 34 ml/kg). Low tidal-volume ventilation (LVT 9 ml/kg) was used in control groups. PEEP was set to 2 cm H2O, FiO2 was 0.5 in all groups. HVT and LVT mice were ventilated with either I:E of 1:2 (LVT 1:2, HVT 1:2) or 1:1 (LVT 1:1, HVT 1:1) for 4 hours or until an alternative end point, defined as mean arterial blood pressure below 40 mm Hg. Dynamic hyperinflation due to the increased I:E ratio was excluded in a separate group of animals. Survival, lung compliance, oxygenation, pulmonary permeability, markers of pulmonary and systemic inflammation (leukocyte differentiation in lung and blood, analyses of pulmonary interleukin-6, interleukin-1β, keratinocyte-derived chemokine, monocyte chemoattractant protein-1), and histopathologic pulmonary changes were analyzed. LVT 1:2 or LVT 1:1 did not result in VILI, and all individuals survived the ventilation period. HVT 1:2 decreased lung compliance, increased pulmonary neutrophils and cytokine expression, and evoked marked histologic signs of lung injury. All animals survived. HVT 1:1 caused further significant worsening of oxygenation, compliance and increased pulmonary proinflammatory cytokine expression, and pulmonary and blood neutrophils. In the HVT 1:1 group, significant mortality during mechanical ventilation was observed. According to the "baby lung

  8. A Cycle Ergometer Exercise Program Improves Exercise Capacity and Inspiratory Muscle Function in Hospitalized Patients Awaiting Heart Transplantation: a Pilot Study

    PubMed Central

    Forestieri, Patrícia; Guizilini, Solange; Peres, Monique; Bublitz, Caroline; Bolzan, Douglas W.; Rocco, Isadora S.; Santos, Vinícius B.; Moreira, Rita Simone L.; Breda, João R.; de Almeida, Dirceu R.; Carvalho, Antonio Carlos de C.; Arena, Ross; Gomes, Walter J.

    2016-01-01

    Objective The purpose of this study was to evaluate the effect of a cycle ergometer exercise program on exercise capacity and inspiratory muscle function in hospitalized patients with heart failure awaiting heart transplantation with intravenous inotropic support. Methods Patients awaiting heart transplantation were randomized and allocated prospectively into two groups: 1) Control Group (n=11) - conventional protocol; and 2) Intervention Group (n=7) - stationary cycle ergometer exercise training. Functional capacity was measured by the six-minute walk test and inspiratory muscle strength assessed by manovacuometry before and after the exercise protocols. Results Both groups demonstrated an increase in six-minute walk test distance after the experimental procedure compared to baseline; however, only the intervention group had a significant increase (P=0.08 and P=0.001 for the control and intervention groups, respectively). Intergroup comparison revealed a greater increase in the intervention group compared to the control (P<0.001). Regarding the inspiratory muscle strength evaluation, the intragroup analysis demonstrated increased strength after the protocols compared to baseline for both groups; statistical significance was only demonstrated for the intervention group, though (P=0.22 and P<0.01, respectively). Intergroup comparison showed a significant increase in the intervention group compared to the control (P<0.01). Conclusion Stationary cycle ergometer exercise training shows positive results on exercise capacity and inspiratory muscle strength in patients with heart failure awaiting cardiac transplantation while on intravenous inotropic support. PMID:27982348

  9. Finite Element Model and Validation of Nasal Tip Deformation

    PubMed Central

    Manuel, Cyrus T; Harb, Rani; Badran, Alan; Ho, David; Wong, Brian JF

    2016-01-01

    Nasal tip mechanical stability is important for functional and cosmetic nasal airway surgery. Palpation of the nasal tip provides information on tip strength to the surgeon, though it is a purely subjective assessment. Providing a means to simulate nasal tip deformation with a validated model can offer a more objective approach in understanding the mechanics and nuances of the nasal tip support and eventual nasal mechanics as a whole. Herein we present validation of a finite element (FE) model of the nose using physical measurements recorded using an ABS plastic-silicone nasal phantom. Three-dimensional photogrammetry was used to capture the geometry of the phantom at rest and while under steady state load. The silicone used to make the phantom was mechanically tested and characterized using a linear elastic constitutive model. Surface point clouds of the silicone and FE model were compared for both the loaded and unloaded state. The average Hausdorff distance between actual measurements and FE simulations across the nose were 0.39mm ± 1.04 mm and deviated up to 2mm at the outermost boundaries of the model. FE simulation and measurements were in near complete agreement in the immediate vicinity of the nasal tip with millimeter accuracy. We have demonstrated validation of a two-component nasal FE model, which could be used to model more complex modes of deformation where direct measurement may be challenging. This is the first step in developing a nasal model to simulate nasal mechanics and ultimately the interaction between geometry and airflow. PMID:27633018

  10. Finite Element Model and Validation of Nasal Tip Deformation.

    PubMed

    Manuel, Cyrus T; Harb, Rani; Badran, Alan; Ho, David; Wong, Brian J F

    2017-03-01

    Nasal tip mechanical stability is important for functional and cosmetic nasal airway surgery. Palpation of the nasal tip provides information on tip strength to the surgeon, though it is a purely subjective assessment. Providing a means to simulate nasal tip deformation with a validated model can offer a more objective approach in understanding the mechanics and nuances of the nasal tip support and eventual nasal mechanics as a whole. Herein we present validation of a finite element (FE) model of the nose using physical measurements recorded using an ABS plastic-silicone nasal phantom. Three-dimensional photogrammetry was used to capture the geometry of the phantom at rest and while under steady state load. The silicone used to make the phantom was mechanically tested and characterized using a linear elastic constitutive model. Surface point clouds of the silicone and FE model were compared for both the loaded and unloaded state. The average Hausdorff distance between actual measurements and FE simulations across the nose were 0.39 ± 1.04 mm and deviated up to 2 mm at the outermost boundaries of the model. FE simulation and measurements were in near complete agreement in the immediate vicinity of the nasal tip with millimeter accuracy. We have demonstrated validation of a two-component nasal FE model, which could be used to model more complex modes of deformation where direct measurement may be challenging. This is the first step in developing a nasal model to simulate nasal mechanics and ultimately the interaction between geometry and airflow.

  11. Nasal Myiasis in Hinduism and Contemporary Otorhinolaryngology.

    PubMed

    Bosmia, Anand N; Zimmermann, Terence M; Griessenauer, Christoph J; Shane Tubbs, R; Rosenthal, Eben L

    2017-08-01

    Various case reports on nasal myiasis written during the 1990s and 2000s state that nasal myiasis, which is known as peenash among South Asian natives, is a form of divine punishment in Hindu mythology, but do not provide citations from Hindu scriptures that would suggest this interpretation. This paper aims to discuss the phenomenon of peenash in a historical context by examining medical literature written during the nineteenth and early twentieth centuries, to identify Hindu texts contributing to the belief of some Hindus that nasal myiasis is a form of divine punishment, and to provide an overview of contemporary treatment for and management of nasal myiasis.

  12. Unilateral nasal pain with migraine features.

    PubMed

    Alvarez, Mónica; Montojo, Teresa; de la Casa, Beatriz; Vela, Lydia; Pareja, Juan A

    2013-09-01

    Migraine attacks exclusively felt in the face are very rare, the pain involving the territories supplied by the second and third branches of the trigeminal nerve. Two patients suffering from heminasal pain attacks accompanied with typical migrainous features and responsive to oral or intranasal triptans - but not to intranasal lidocaine or oxymetazoline. In one patient, the attacks could be precipitated upon slight touching on the tip of the nose, in the other attacks were preceded by the nasal sensation typically heralding sneezing. Migraine pain mostly develops within the innervation territory of the first branch of the trigeminal nerve, which includes the nose. Therefore, episodes of unilateral nasal pain with migrainous features could be considered a migraine with unusual topography (nasal migraine). Painful nasal attacks occasionally preceded by stimulation of trigeminal afferents in the nose, could be conceived of as migraine-tic syndrome.

  13. Physiologic effects of alveolar recruitment and inspiratory pauses during moderately-high-frequency ventilation delivered by a conventional ventilator in a severe lung injury model

    PubMed Central

    Costa, Eduardo Leite Vieira; Azevedo, Luciano Cesar Pontes; Gomes, Susimeire; Amato, Marcelo Britto Passos; Park, Marcelo

    2017-01-01

    Background and aims To investigate whether performing alveolar recruitment or adding inspiratory pauses could promote physiologic benefits (VT) during moderately-high-frequency positive pressure ventilation (MHFPPV) delivered by a conventional ventilator in a porcine model of severe acute respiratory distress syndrome (ARDS). Methods Prospective experimental laboratory study with eight pigs. Induction of acute lung injury with sequential pulmonary lavages and injurious ventilation was initially performed. Then, animals were ventilated on a conventional mechanical ventilator with a respiratory rate (RR) = 60 breaths/minute and PEEP titrated according to ARDS Network table. The first two steps consisted of a randomized order of inspiratory pauses of 10 and 30% of inspiratory time. In final step, we removed the inspiratory pause and titrated PEEP, after lung recruitment, with the aid of electrical impedance tomography. At each step, PaCO2 was allowed to stabilize between 57–63 mmHg for 30 minutes. Results The step with RR of 60 after lung recruitment had the highest PEEP when compared with all other steps (17 [16,19] vs 14 [10, 17]cmH2O), but had lower driving pressures (13 [13,11] vs 16 [14, 17]cmH2O), higher P/F ratios (212 [191,243] vs 141 [105, 184] mmHg), lower shunt (23 [20, 23] vs 32 [27, 49]%), lower dead space ventilation (10 [0, 15] vs 30 [20, 37]%), and a more homogeneous alveolar ventilation distribution. There were no detrimental effects in terms of lung mechanics, hemodynamics, or gas exchange. Neither the addition of inspiratory pauses or the alveolar recruitment maneuver followed by decremental PEEP titration resulted in further reductions in VT. Conclusions During MHFPPV set with RR of 60 bpm delivered by a conventional ventilator in severe ARDS swine model, neither the inspiratory pauses or PEEP titration after recruitment maneuver allowed reduction of VT significantly, however the last strategy decreased driving pressures and improved both shunt

  14. Naegleria fowleri immunization modifies lymphocytes and APC of nasal mucosa.

    PubMed

    Carrasco-Yepez, M M; Campos-Rodríguez, R; Reséndiz-Albor, A A; Peña-Juárez, C; Contis-Montes de Oca, A; Arciniega-Martínez, I M; Bonilla-Lemus, P; Rojas-Hernandez, S

    2018-03-01

    We investigated whether intranasal immunization with amoebic lysates plus cholera toxin modified the populations of T and B lymphocytes, macrophages and dendritic cells by flow cytometry from nose-associated lymphoid tissue (NALT), cervical lymph nodes (CN), nasal passages (NP) and spleen (SP). In all immunized groups, the percentage of CD4 was higher than CD8 cells. CD45 was increased in B cells from mice immunized. We observed IgA antibody-forming cell (IgA-AFC) response, mainly in NALT and NP. Macrophages from NP and CN expressed the highest levels of CD80 and CD86 in N. fowleri lysates with either CT or CT alone immunized mice, whereas dendritic cells expressed high levels of CD80 and CD86 in all compartment from immunized mice. These were lower than those expressed by macrophages. Only in SP from CT-immunized mice, these costimulatory molecules were increased. These results suggest that N. fowleri and CT antigens are taking by APCs, and therefore, protective immunity depends on interactions between APCs and T cells from NP and CN. Consequently, CD4 cells stimulate the differentiation from B lymphocytes to AFC IgA-positive; antibody that we previously found interacting with trophozoites in the nasal lumen avoiding the N. fowleri attachment to nasal epithelium. © 2017 John Wiley & Sons Ltd.

  15. Nose and Nasal Planum Neoplasia, Reconstruction.

    PubMed

    Worley, Deanna R

    2016-07-01

    Most intranasal lesions are best treated with radiation therapy. Computed tomographic imaging with intravenous contrast is critical for treatment planning. Computed tomographic images of the nose will best assess the integrity of the cribriform plate for central nervous system invasion by a nasal tumor. Because of an owner's emotional response to an altered appearance of their dog's face, discussions need to include the entire family before proceeding with nasal planectomy or radical planectomy. With careful case selection, nasal planectomy and radical planectomy surgeries can be locally curative. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Measurement of nasal patency in anesthetized and conscious dogs.

    PubMed

    Koss, Michael C; Yu, Yongxin; Hey, John A; McLeod, Robbie L

    2002-02-01

    Experiments were undertaken to characterize a noninvasive chronic, model of nasal congestion in which nasal patency is measured using acoustic rhinometry. Compound 48/80 was administered intranasally to elicit nasal congestion in five beagle dogs either by syringe (0.5 ml) in thiopental sodium-anesthetized animals or as a mist (0.25 ml) in the same animals in the conscious state. Effects of mast cell degranulation on nasal cavity volume as well as on minimal cross-sectional area (A(min)) and intranasal distance to A(min) (D(min)) were studied. Compound 48/80 caused a dose-related decrease in nasal cavity volume and A(min) together with a variable increase in D(min). Maximal responses were seen at 90-120 min. Compound 48/80 was less effective in producing nasal congestion in conscious animals, which also had significantly larger basal nasal cavity volumes. These results demonstrate the utility of using acoustic rhinometry to measure parameters of nasal patency in dogs and suggest that this model may prove useful in studies of the actions of decongestant drugs.

  17. Numerical Simulation of Airway Dimension Effects on Airflow Patterns and Odorant Deposition Patterns in the Rat Nasal Cavity

    PubMed Central

    Wei, Zehong; Xu, Zhixiang; Li, Bo; Xu, Fuqiang

    2013-01-01

    The sense of smell is largely dependent on the airflow and odorant transport in the nasal cavity, which in turn depends on the anatomical structure of the nose. In order to evaluate the effect of airway dimension on rat nasal airflow patterns and odorant deposition patterns, we constructed two 3-dimensional, anatomically accurate models of the left nasal cavity of a Sprague-Dawley rat: one was based on high-resolution MRI images with relatively narrow airways and the other was based on artificially-widening airways of the MRI images by referencing the section images with relatively wide airways. Airflow and odorant transport, in the two models, were determined using the method of computational fluid dynamics with finite volume method. The results demonstrated that an increase of 34 µm in nasal airway dimension significantly decreased the average velocity in the whole nasal cavity by about 10% and in the olfactory region by about 12% and increased the volumetric flow into the olfactory region by about 3%. Odorant deposition was affected to a larger extent, especially in the olfactory region, where the maximum odorant deposition difference reached one order of magnitude. The results suggest that a more accurate nasal cavity model is necessary in order to more precisely study the olfactory function of the nose when using the rat. PMID:24204875

  18. Hygroscopic condenser humidifier as a solution to nasal dryness due to nasal CPAP treatment for obstructive sleep apnea syndrome.

    PubMed

    Parra, O; Klamburg, J; Xirgu, J; Abad, J; Sala, H; Tomasa, A; Morera, J

    1991-04-01

    We report an apparent solution to nasal dryness for patients with obstructive sleep apnea syndrome treated with nasal continuous positive airway pressure (CPAP) when a hygroscopic condenser humidifier is introduced into the CPAP circuit. Six patients underwent a 5-h test period of nasal CPAP therapy with a mask containing a hygroscopic humidifier. The water vapor showed a statistically significant increase in both inspired and expired gases. The relative humidity of the inspired gases increased significantly. The levels of O2 and CO2 in the respired gases did not change. When patients were asked about nasal dryness at the end of the test, all of them reported marked improvement.

  19. Patient experience with mupirocin or povidone-iodine nasal decolonization.

    PubMed

    Maslow, Jed; Hutzler, Lorraine; Cuff, Germaine; Rosenberg, Andrew; Phillips, Michael; Bosco, Joseph

    2014-06-01

    Led by the federal government, the payers of health care are enacting policies designed to base provider reimbursement on the quality of care they render. This study evaluated and compared patient experiences and satisfaction with nasal decolonization with either nasal povidone-iodine (PI) or nasal mupirocin ointment (MO). A total of 1903 patients were randomized to undergo preoperative nasal decolonization with either nasal MO or PI solution. All randomized patients were also given 2% chlorhexidine gluconate topical wipes. Patients were interviewed prior to discharge to assess adverse events and patient experience with their assigned preoperative antiseptic protocol. Of the 1903 randomized patients, 1679 (88.1%) were interviewed prior to discharge. Of patients receiving PI, 3.4% reported an unpleasant or very unpleasant experience, compared with 38.8% of those using nasal MO (P<.0001). Sixty-seven percent of patients using nasal MO believed it to be somewhat or very helpful in reducing surgical site infections, compared with 71% of patients receiving PI (P>.05). Being recruited as an active participant in surgical site infection prevention was a positive experience for 87.2% of MO patients and 86.3% of PI patients (P=.652). Those assigned to receive PI solution preoperatively reported significantly fewer adverse events than the nasal MO group (P<.01). Preoperative nasal decolonization with either nasal PI or MO was considered somewhat or very helpful by more than two-thirds of patients. Copyright 2014, SLACK Incorporated.

  20. Nasal reaction to changes in whole body temperature.

    PubMed

    Lundqvist, G R; Pedersen, O F; Hilberg, O; Nielsen, B

    1993-11-01

    The changes in nasal patency following a 1.5 degrees C decrease or increase in whole body temperature were measured in 8 healthy young males, during and after 30 min of immersion in a 15 degrees C cold or a 40 degrees C warm bath, breathing air at the same temperature, in a cross-over experimental design. The nasal reactions were traced by consecutive measurements of changes in nasal cavity volumes by acoustic rhinometry. Swelling of the mucosa during cooling and an almost maximal shrinkage of the mucosa during heating were indicated by respectively a decrease and an increase in nasal cavity volumes. The reactions were determined predominantly by the whole body thermal balance, but were also influenced by the temperature of the inhaled air, either enhanced, reduced or temporarily reversed. The greatest change occurred in the nasal cavity, left or right, which differed most from the final state at the beginning of exposure due to the actual state of nasal cycle.

  1. ``Magical'' fluid pathways: inspired airflow corridors for optimal drug delivery to human sinuses

    NASA Astrophysics Data System (ADS)

    Basu, Saikat; Farzal, Zainab; Kimbell, Julia S.

    2017-11-01

    Topical delivery methods like nasal sprays are an important therapeutic component for sinusitis (inflammation and clogging of the paranasal sinuses). The sinuses are air-filled sacs, identified as: maxillaries (under the eyes and deep to cheeks bilaterally; largest in volume), frontals (above and medial to the eyes, behind forehead area), ethmoids (between the eyes, inferior to the frontal sinuses), and sphenoids (superior and posterior to ethmoids). We develop anatomic CT-based 3D reconstructions of the human nasal cavity for multiple subjects. Through CFD simulations on Fluent for measured breathing rates, we track inspiratory airflow in all the models and the corresponding sprayed drug transport (for a commercially available sprayer, with experimentally tested particle size distributions). The protocol is implemented for a wide array of spray release points. We make the striking observation that the same release points in each subject provide better particle deposition in all the sinuses, despite the sinuses being located at different portions of the nasal cavity. This leads to the conjecture that the complicated anatomy-based flow physics artifacts in the nasal canal generate certain ``magical'' streamlines, providing passage for improved drug transport to all sinus targets. Supported by NIH Grant R01 HL122154.

  2. Effect of bilastine upon nasal obstruction.

    PubMed

    Dávila, I; Sastre, J; Mullol, J; Montoro, J; Jáuregui, I; Ferrer, M; del Cuvillo, A; Bartra, J; Valero, A

    2011-01-01

    H1 antihistamines constitute one of the main references for the treatment of allergic rhinitis. Classically, these drugs have been considered effective in controlling sneezing, rhinorrhea and itching, though they have not been regarded as particularly effective in application to nasal obstruction. The most recent studies, involving second-generation H1 antihistamines (desloratadine, fexofenadine, levocetirizine, rupatadine), have shown these drugs to offer effects upon nasal obstruction significantly superior to those of placebo. The present review examines the effect of bilastine, a new, potent and highly specific H1 antihistamine without sedative effects or cardiac toxicity, upon nasal obstruction. The analysis of the data from the different clinical trials indicates that in patients with allergic rhinitis, the effect of bilastine upon nasal obstruction is superior to that of placebo and similar to that of other second-generation H1 antihistamines, manifesting within 24 hours after the start of treatment.

  3. High-Flow Nasal Cannula versus Conventional Oxygen Therapy in Children with Respiratory Distress.

    PubMed

    Sitthikarnkha, Punthila; Samransamruajkit, Rujipat; Prapphal, Nuanchan; Deerojanawong, Jitladda; Sritippayawan, Suchada

    2018-05-01

    The aim of this study is to determine the clinical efficacy of high-flow nasal cannula (HFNC) therapy compared with conventional oxygen therapy in children presented with respiratory distress. This was a randomized controlled study. Infants and children aged between 1 month to 5 years who were admitted to our tertiary referral center for respiratory distress (July 1, 2014 to March 31, 2015) and met the inclusion criteria were recruited. Infants and children hospitalized with respiratory distress were randomized into two groups of interventions. All clinical data, for example, respiratory score, pulse rate, and respiratory rate were recorded. The results were subsequently analyzed. A total of 98 respiratory distress children were enrolled during the study period. Only 4 children (8.2%) failed in HFNC therapy, compared with 10 children (20.4%) in conventional oxygen therapy group ( P = 0.09). After adjusted for body weight, underlying diseases, and respiratory distress score, there was an 85% reduction in the odds of treatment failure in HFNC therapy group (adjusted odds ratio 0.15, 95% confidence interval 0.03-0.66, P = 0.01). Most children in HFNC therapy group had significant improvement in clinical respiratory score, heart rate, and respiratory rate at 240, 360, and 120 min compared with conventional oxygen therapy ( P = 0.03, 0.04, and 0.03). HFNC therapy revealed a potential clinical advantage in management children hospitalized with respiratory distress compared with conventional respiratory therapy. The early use of HFNC in children with moderate-to-severe respiratory distress may prevent endotracheal tube intubation. TCTR 20170222007.

  4. Inhalation of diethylamine--acute nasal effects and subjective response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundqvist, G.R.; Yamagiwa, M.; Pedersen, O.F.

    1992-03-01

    Adult volunteers were exposed to 25 ppm (75 mg/m3) diethylamine in a climate chamber for 15 min in order to study the acute nasal reactions to an exposure equivalent to the present threshold limit value-short-term exposure limit. Changes in nasal volume and nasal resistance were measured by acoustic rhinometry and by rhinomanometry. Acute change in nasal volume, usually seen as acute nasal mucosa response to thermal stimuli, was not observed, nor was an acute change in nasal airway resistance. In a subsequent experiment, the aim was to measure acute sensory effects. Exposure to a concentration increasing from 0 to 12more » ppm took place for 60 min, equal to an average concentration of 10 ppm (30 mg/m3). A moderate to strong olfactory response and distinct nasal and eye irritation were observed. In spite of considerable individual variation, the results were in agreement with sensory effect estimates obtained from animal studies.« less

  5. Chronic Rhinosinusitis with Nasal Polyps

    PubMed Central

    Stevens, Whitney W.; Schleimer, Robert P.; Kern, Robert C.

    2016-01-01

    Chronic rhinosinusitis with nasal polyps (CRSwNP) is an important clinical entity diagnosed by the presence of both subjective and objective evidence of chronic sinonasal inflammation. Symptoms include anterior or posterior rhinorrhea, nasal congestion, hyposmia and/or facial pressure or pain that last for greater than 12 weeks duration. Nasal polyps are inflammatory lesions that project into the nasal airway, are typically bilateral, and originate from the ethmoid sinus. Males are more likely to be affected than females but no specific genetic or environmental factors have been strongly linked to the development of this disorder to date. CRSwNP is frequently associated with asthma and allergic rhinitis but the cellular and molecular mechanisms that contribute to the clinical symptoms are not fully understood. Defects in the sinonasal epithelial cell barrier, increased exposure to pathogenic and colonized bacteria, and dysregulation of the host immune system are all thought to play prominent roles in disease pathogenesis. Additional studies are needed to further explore the clinical and pathophysiological features of CRSwNP so that biomarkers can be identified and novel advances can be made to improve the treatment and management of this disease. PMID:27393770

  6. Breathing life into dinosaurs: tackling challenges of soft-tissue restoration and nasal airflow in extinct species.

    PubMed

    Bourke, Jason M; Porter, W M Ruger; Ridgely, Ryan C; Lyson, Tyler R; Schachner, Emma R; Bell, Phil R; Witmer, Lawrence M

    2014-11-01

    The nasal region plays a key role in sensory, thermal, and respiratory physiology, but exploring its evolution is hampered by a lack of preservation of soft-tissue structures in extinct vertebrates. As a test case, we investigated members of the "bony-headed" ornithischian dinosaur clade Pachycephalosauridae (particularly Stegoceras validum) because of their small body size (which mitigated allometric concerns) and their tendency to preserve nasal soft tissues within their hypermineralized skulls. Hypermineralization directly preserved portions of the olfactory turbinates along with an internal nasal ridge that we regard as potentially an osteological correlate for respiratory conchae. Fossil specimens were CT-scanned, and nasal cavities were segmented and restored. Soft-tissue reconstruction of the nasal capsule was functionally tested in a virtual environment using computational fluid dynamics by running air through multiple models differing in nasal soft-tissue conformation: a bony-bounded model (i.e., skull without soft tissue) and then models with soft tissues added, such as a paranasal septum, a scrolled concha, a branched concha, and a model combining the paranasal septum with a concha. Deviations in fluid flow in comparison to a phylogenetically constrained sample of extant diapsids were used as indicators of missing soft tissue. Models that restored aspects of airflow found in extant diapsids, such as appreciable airflow in the olfactory chamber, were judged as more likely. The model with a branched concha produced airflow patterns closest to those of extant diapsids. These results from both paleontological observation and airflow modeling indicate that S. validum and other pachycephalosaurids could have had both olfactory and respiratory conchae. Although respiratory conchae have been linked to endothermy, such conclusions require caution in that our re-evaluation of the reptilian nasal apparatus indicates that respiratory conchae may be more widespread

  7. Hemodynamics Associated with Breathing Through an Inspiratory Impedance Threshold Device in Human Volunteers

    DTIC Science & Technology

    2004-01-01

    nerve stimulation combined with an inspiratory impedance threshold in a pig model of hemorrhagic shock. Crit Care Med 2003; 31:1197–1202 16. Coast JR...training. Because of the po- tential effects on cardiovascular function, sub- jects refrained from exercise and stimulants such as caffeine and other...controlled trial. Setting: Laboratory. Subjects: Ten women and ten men. Interventions: We measured hemodynamic and respiratory re- sponses during two

  8. Influence of the upper airway on breathing pattern and expiratory time constant in unanesthetized dog pups.

    PubMed

    England, S J; Stogryn, H A

    1986-11-01

    Unanesthetized dog pups (2 to 31 days old) respond to sudden opening of a tracheal cannula to atmospheric pressure with a marked increase in breathing frequency. This response is achieved with a 25% decrease in inspiratory and 40% decrease in expiratory times. Expiratory thyroarytenoid muscle activity increased concomitantly, while inspiratory diaphragmatic and posterior cricoarytenoid muscle activities were reduced. These responses are interpreted as a compensatory mechanism for maintenance of an elevated end-expiratory lung volume with functional loss of the upper airway. The changes in expiratory time and thyroarytenoid muscle activity were not observed when positive pressure was applied at the trachea. The expiratory time constant was assessed during spontaneous breathing. The mean value was twice as long during nasal breathing than during tracheal breathing. The nasal value was substantially increased when the thyroarytenoid muscle was active during expiration.

  9. Effect of formulation- and administration-related variables on deposition pattern of nasal spray pumps evaluated using a nasal cast.

    PubMed

    Kundoor, Vipra; Dalby, Richard N

    2011-08-01

    To systematically evaluate the effect of formulation- and administration-related variables on nasal spray deposition using a nasal cast. Deposition pattern was assessed by uniformly coating a transparent nose model with Sar-Gel®, which changes from white to purple on contact with water. Sprays were subsequently discharged into the cast, which was then digitally photographed. Images were quantified using Adobe® Photoshop. The effects of formulation viscosity (which influences droplet size), simulated administration techniques (head orientation, spray administration angle, spray nozzle insertion depth), spray pump design and metering volume on nasal deposition pattern were investigated. There was a significant decrease in the deposition area associated with sprays of increasing viscosity. This appeared to be mediated by an increase in droplet size and a narrowing of the spray plume. Administration techniques and nasal spray pump design also had a significant effect on the deposition pattern. This simple color-based method provides quantitative estimates of the effects that different formulation and administration variables may have on the nasal deposition area, and provides a rational basis on which manufacturers of nasal sprays can base their patient instructions or post approval changes when it is impractical to optimize these using a clinical study.

  10. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    PubMed Central

    Togni Filho, Paulo Henrique; Casagrande, João Luiz Marin; Lederman, Henrique Manoel

    2017-01-01

    Objective To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. PMID:28428651

  11. Effect of early correction of nasal septal deformity in unilateral cleft lip and palate on inferior turbinate hypertrophy and nasal patency.

    PubMed

    Pinto, Valentina; Piccin, Ottavio; Burgio, Luca; Summo, Valeria; Antoniazzi, Elisa; Morselli, Paolo G

    2018-05-01

    A relatively neglected aspect of cleft lip nasal deformity is the effect of septal deviation and inferior turbinate hypertrophy (ITH) on the functional airway. In particular, ITH in the noncleft side can be especially problematic, because it reduces the healthy nasal area, creating bilateral nasal obstruction that might affect the growth of the maxillofacial skeleton. Although these anatomic and functional changes are documented, few recommendations have been developed regarding the proper approach to ITH. The aim of the present study was to asses the ITH severity and determine the degree of nasal airway patency in patients who have undergone primary correction of the nasal septum during lip repair compared to patients operated on without primary septal correction. The study population included two groups. One group consisted of twenty unilateral cleft lip palate UCLP patients who have previously undergone primary rhinoseptoplasty as part of their treatment plan. The control group consisted of twenty UCLP patients operated on without rhinoseptal correction. The Nasal Obstructive Symptom Evaluation (NOSE) scale and nasal endoscopy were used to assess nasal obstruction. The overall untreated group reported severe symptoms across all NOSE scale dimensions more frequently than children who have undergone primary rhinoseptoplasty. The difference was statistically significant for each dimensions (p < 0.05). The mean NOSE score for group A and group B was 21.4 ± 9.4 and 70.8 ± 17.2 respectively (p < 0.0001). In group A turbinate size decreased significantly (p < 0.05) compared to pre-operative data. Comparing the two groups a statistically significant difference in turbinate size was observed (p < 0.0001). The results of the present study confirm that there is a significant degree of ITH and nasal airway dysfunction in patients with UCLP. Early septal repositioning during primary cleft lip repair results in a statistically significant reduction in IT

  12. A retrospective study of chronic nasal disease in 75 dogs.

    PubMed

    Lobetti, R G

    2009-12-01

    Chronic nasal disease is a common problem in dogs. To determine the aetiology, a retrospective study in 75 dogs with persistent and chronic nasal disease was done. All dogs were evaluated by means of survey nasal radiographs, antegrade and retrograde rhinoscopy, bacterial and fungal cultures, and histopathology. A definitive diagnosis was made in 74/75 cases (98.6%). Nasal neoplasia was the most common diagnosis (46.7%), median age 108 months, followed by lympho-plasmacytic rhinitis (20%), median age 112 months, and fungal rhinitis (10.7%), median age 53.5 months. Other diagnoses included nasal foreign body (5.3%), median age 51 months, and primary bacterial rhinitis (6.7%), median age 116.5 months. Rare aetiologies identified were nasal polyps, granulomatous rhinitis, oro-nasal fistula and naso-pharyngeal stenosis. This study showed that by using a structured combination of survey radiography, rhinoscopy, cultures and histopathology, a diagnosis could be made in dogs with chronic nasal disease.

  13. Nasal reconstruction after epithelioma.

    PubMed

    Rodríguez-Camps, S

    2001-01-01

    In this paper we present our procedure for the treatment, histopathological diagnosis, and resection of skin cancer in the nasal pyramid and its subsequent reconstruction. Because we are dealing with the most important anatomical feature of the face our goal is an aesthetic reconstruction [2,4] according to the anatomical subunits criterion of Burget [3]. First, a histopathological diagnosis is made to determine the nature of the tumor. Then, we proceed with the resection according to the Mohs Micrographic Surgery [1,5,7]. Then we begin with the first step of the nasal reconstruction.

  14. [High flow nasal cannula oxygen therapy in the treatment of acute bronchiolitis in neonates].

    PubMed

    Bermúdez Barrezueta, Lorena; García Carbonell, Nuria; López Montes, Jorge; Gómez Zafra, Rafael; Marín Reina, Purificación; Herrmannova, Jana; Casero Soriano, Javier

    2017-01-01

    To determine whether the availability of heated humidified high-flow nasal cannula (HFNC) therapy was associated with a decrease in need for mechanical ventilation in neonates hospitalised with acute bronchiolitis. A combined retrospective and prospective (ambispective) cohort study was performed in a type II-B Neonatal Unit, including hospitalised neonates with acute bronchiolitis after the introduction of HFNC (HFNC-period; October 2011-April 2015). They were compared with a historical cohort prior to the availability of this technique (pre-HFNC; January 2008-May 2011). The need for mechanical ventilation between the two study groups was analysed. Clinical parameters and technique-related complications were evaluated in neonates treated with HFNC. A total of 112 neonates were included, 56 after the introduction of HFNC and 56 from the period before the introduction of HFNC. None of patients in the HFNC-period required intubation, compared with 3.6% of the patients in the pre-HFNC group. The availability of HFNC resulted in a significant decrease in the need for non-invasive mechanical ventilation (30.4% vs 10.7%; P=.01), with a relative risk (RR) of .353 (95% CI; .150-.829), an absolute risk reduction (ARR) of 19.6% (95% CI; 5.13 - 34.2), yielding a NNT of 5. In the HFNC-period, 22 patients received high flow therapy, and 22.7% (95% CI; 7.8 to 45.4) required non-invasive ventilation. Treatment with HFNC was associated with a significant decrease in heart rate (P=.03), respiratory rate (P=.01), and an improvement in the Wood-Downes Férres score (P=.00). No adverse effects were observed. The availability of HFNC reduces the need for non-invasive mechanical ventilation, allowing a safe and effective medical management of neonates with acute bronchiolitis. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Flow volume loops in patients with goiters.

    PubMed Central

    Geraghty, J G; Coveney, E C; Kiernan, M; O'Higgins, N J

    1992-01-01

    Plain radiology is the standard means of assessing upper airway obstruction in patients with goiters. Flow volume loop curves will provide additional information, because they allow a quantitative assessment of airflow dynamics in the respiratory cycle. Fifty-one patients had flow volume loops performed before and after thyroidectomy. There was a significant increase in the maximum inspiratory flow rate (3.9 +/- 0.2 versus 4.9 +/- 0.2 L/second, p less than 0.01) after thyroidectomy. Eight of twelve patients with normal tracheal radiology had improved airflow dynamics in the postoperative period. The flow volume loop curve is a simple noninvasive means of assessing airflow dynamics in patients with goiters and may be superior to conventional radiology. PMID:1731653

  16. Dialectal and gender differences in nasalance for a Mandarin population.

    PubMed

    Kim, Ha-Kyung; Yu, Xiao-meng; Cao, Yan-jing; Liu, Xiao-ming; Huang, Zhao-Ming

    2016-01-01

    The purpose of this study was to determine whether there are dialectal and gender related differences in nasalance of main Mandarin vowels and three sentences in 400 Chinese normal adults. The mean nasalance score difference for dialect and gender was significant (p < .001) in all speech materials. For different dialects, the average nasalance scores show that Chongqing > Beijing > Shanghai > Guangzhou for the nasal sentence, oro-nasal sentence, /a/, /i/ and /u/. In addition, the average nasalance scores of females were higher than those of males for all speech materials in all dialects. The clinical significance of this study can be helpful in making nasalance clinical decisions for Chinese people with cleft palate, hearing disorders and dysarthria with resonance disorders. It also shows the theoretical and socio-cultural features for linguists considering dialects and gender.

  17. Response of Preterm Infants to 2 Noninvasive Ventilatory Support Systems: Nasal CPAP and Nasal Intermittent Positive-Pressure Ventilation.

    PubMed

    Silveira, Carmen Salum Thomé; Leonardi, Kamila Maia; Melo, Ana Paula Carvalho Freire; Zaia, José Eduardo; Brunherotti, Marisa Afonso Andrade

    2015-12-01

    Noninvasive ventilation (NIV) in preterm infants is currently applied using intermittent positive pressure (2 positive-pressure levels) or in a conventional manner (one pressure level). However, there are no studies in the literature comparing the chances of failure of these NIV methods. The aim of this study was to evaluate the occurrence of failure of 2 noninvasive ventilatory support systems in preterm neonates over a period of 48 h. A randomized, prospective, clinical study was conducted on 80 newborns (gestational age < 37 weeks, birthweight < 2,500 g). The infants were randomized into 2 groups: 40 infants were treated with nasal CPAP and 40 infants with nasal intermittent positive-pressure ventilation (NIPPV). The occurrence of apnea, progression of respiratory distress, nose bleeding, and agitation was defined as ventilation failure. The need for intubation and re-intubation after failure was also observed. There were no significant differences in birth characteristics between groups. Ventilatory support failure was observed in 25 (62.5%) newborns treated with nasal CPAP and in 12 (30%) newborns treated with NIPPV, indicating an association between NIV failure and the absence of intermittent positive pressure (odds ratio [OR] 1.22, P < .05). Apnea (32.5%) was the main reason for nasal CPAP failure. After failure, 25% (OR 0.33) of the newborns receiving nasal CPAP and 12.5% (OR 0.14) receiving NIPPV required invasive mechanical ventilation. Ventilatory support failure was significantly more frequent when nasal CPAP was used. Copyright © 2015 by Daedalus Enterprises.

  18. Accumulation of CD69+ tissue‑resident memory T cells in the nasal polyps of patients with chronic rhinosinusitis.

    PubMed

    Ickrath, Pascal; Kleinsasser, Norbert; Ding, Xin; Ginzkey, Christian; Beyersdorf, Niklas; Hagen, Rudolf; Kerkau, Thomas; Hackenberg, Stephan

    2018-08-01

    In patients with chronic rhinosinusitis with nasal polyps (CRSwNP), a relative accumulation of cluster of differentiation (CD)8+ T cells over CD4+ T cells occurs in nasal polyps compared with the peripheral blood. Nasal CD8+ T cells and CD4+ T cells predominantly present an effector memory phenotype. Immunological studies have reported that memory T cells recirculate from the tissues to the peripheral blood and a high percentage of these T cells persist within the tissue. The aim of the present study was to characterize CD69+ sphingosine‑1‑phosphate receptor 1 (S1PR1)‑ tissue resident memory T cells (Trm) in the polyps of patients with CRSwNP. Tissue and blood samples were collected from 10 patients undergoing nasal sinus surgery. Expression of specific extra‑ and intracellular molecules were analyzed using multicolor flow cytometry. A significantly higher level of CD8+ T cells than CD4+ T cells was present in nasal polyps, while significantly more CD4+ T cells than CD8+ T cells were detected in the peripheral blood of patients with CRSwNP. The frequency of CD69+ T cells was significantly higher in CD8+ and CD4+ T cells in nasal polyps compared with the peripheral blood. The frequency of CD69+ S1PR1‑ Trm was also significantly higher in CD4+ and CD8+ T cells from nasal polyps compared with the peripheral blood. Within polyps, the frequency of CD69+ S1PR1‑ Trm was again significantly higher in CD8+ compared with CD4+ T cells. In summary, a significantly higher frequency of CD69+ S1PR1‑ T cells was observed in the nasal polyps compared with the peripheral blood in patients with CRSwNP. The results of the present study suggest that local regulation of the immune response occurs within nasal polyps. As such, Trm should be considered a potential stimulus in the pathogenesis of nasal polyps. However, the role of Trm in nasal polyps as a pathogenic trigger of the local inflammatory reaction requires further investigation.

  19. The Effect of Menstrual Cycle on Nasal Resonance Characteristics in Females

    ERIC Educational Resources Information Center

    Kumar, Suman; Basu, Shriya; Sinha, Anisha; Chatterjee, Indranil

    2012-01-01

    The purpose of this study was to analyze resonance characteristics (nasality and nasalance values) during the menstrual cycle. Previous studies indicate changes in voice quality and nasal mucosa due to temporary falling estrogen levels in human females during their menstrual cycle. The present study compared the nasality and "nasalance scores"…

  20. Inspiratory Phonation in Baby Voice.

    PubMed

    Wermke, Kathleen; Haschemi, Asin Ahmad; Hesse, Volker; Robb, Michael P

    2018-03-01

    This study aimed to evaluate the developmental occurrence of inspiratory phonations (IPs) in the spontaneous cries of healthy infants across the first 10 weeks of life. This is a populational retrospective study. The spontaneous crying of 17 healthy infants (10 were male) was retrospectively investigated. Sound files of spontaneously uttered cries that were repeatedly recorded once per week for across the first 10 weeks of life were retrospectively analyzed. Frequency spectra and waveforms were used to identify the occurrence of IPs and to measure the duration and fundamental frequency (fo) of each instance of IP. A consistent number of IPs were identified across the 10-week period. All infants were observed to produce IPs in their spontaneous cries, although the frequency of occurrence was not consistent across infants. A marked sex difference was observed with female infants producing a higher number of IPs compared to males. The duration and fo of IPs did not differ significantly across the 10 weeks or between sexes. The production of IPs is a regularly occurring phenomenon in healthy, normally developing infants' spontaneous crying. The proportional difference in the production of IPs between female and male infants, observed for the first time here, is postulated to be linked to sex-based differences (including steroidal hormones) in respiratory anatomy and physiology. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  1. [Objective measurement of normal nasality in the Saxony dialect].

    PubMed

    Müller, R; Beleites, T; Hloucal, U; Kühn, M

    2000-12-01

    In the United States of America, the nasometer was developed by Fletcher as an objective method for measuring nasality. There are no accepted normal values for comparable test materials regarding the German language. The aim of this study was the examination of the auditively normal nasality of Saxon-speaking people with the nasometer. The nasalance of 51 healthy Saxon-speaking test persons with auditively normal nasality was measured with a model 6200 nasometer (Kay-Elemetrics, U.S.A.). The text materials used were the vowels "a", "e", "i", "o", and "u", the sentences "Die Schokolade ist sehr lecker" ("The chocolate is very tasty") and "Nenne meine Mama Mimi" ("Name my mama Mimi"), and the texts of "North wind and sun", "A children's birthday", and an arbitrary selection from Strittmatter. The mean nasalance for the vowels was 17.7%, for the sentence containing no nasal sounds 13.0%, and for the sentence containing many nasal sounds 67.2%. The mean value of the texts was 33-41%. The results for the texts agreed well with the results of Reuter (1997), who examined people from the state of Brandenburg. A range from 20% to 55% is suggested as the normal value for nasalance in the German-speaking area.

  2. A Nasal Brush-based Classifier of Asthma Identified by Machine Learning Analysis of Nasal RNA Sequence Data.

    PubMed

    Pandey, Gaurav; Pandey, Om P; Rogers, Angela J; Ahsen, Mehmet E; Hoffman, Gabriel E; Raby, Benjamin A; Weiss, Scott T; Schadt, Eric E; Bunyavanich, Supinda

    2018-06-11

    Asthma is a common, under-diagnosed disease affecting all ages. We sought to identify a nasal brush-based classifier of mild/moderate asthma. 190 subjects with mild/moderate asthma and controls underwent nasal brushing and RNA sequencing of nasal samples. A machine learning-based pipeline identified an asthma classifier consisting of 90 genes interpreted via an L2-regularized logistic regression classification model. This classifier performed with strong predictive value and sensitivity across eight test sets, including (1) a test set of independent asthmatic and control subjects profiled by RNA sequencing (positive and negative predictive values of 1.00 and 0.96, respectively; AUC of 0.994), (2) two independent case-control cohorts of asthma profiled by microarray, and (3) five cohorts with other respiratory conditions (allergic rhinitis, upper respiratory infection, cystic fibrosis, smoking), where the classifier had a low to zero misclassification rate. Following validation in large, prospective cohorts, this classifier could be developed into a nasal biomarker of asthma.

  3. Disposition of nasal, intravenous, and oral methadone in healthy volunteers.

    PubMed

    Dale, Ola; Hoffer, Christine; Sheffels, Pamela; Kharasch, Evan D

    2002-11-01

    Nasal administration of many opioids demonstrates rapid uptake and fast onset of action. Nasal administration may be an alternative to intravenous and oral administration of methadone and was therefore studied in human volunteers. The study was approved by the Institutional Review Board of the University of Washington, Seattle. Eight healthy volunteers (6 men and 2 women) aged 19 to 33 years were enrolled after informed written consent was obtained. Subjects received 10 mg methadone hydrochloride nasally, orally, or intravenously on 3 separate occasions in a crossover design. Nasal methadone (50 mg/mL in aqueous solution) was given as a 100-microL spray in each nostril (Pfeiffer BiDose sprayer). Blood samples for liquid chromatography-mass spectrometry analyses of methadone and the metabolite 2-ethyl-1,5-dimethyl-3,3-diphenylpyrrolinium were drawn for up to 96 hours. The methadone effect was measured by noninvasive infrared pupilometry coincident with blood sampling. Nasal uptake of methadone was rapid, with maximum plasma concentrations occurring within 7 minutes. The maximum effects of intravenous, nasal, and oral methadone, on the basis of dark-adapted pupil diameter, were reached in about 15 minutes, 30 minutes, and 2 hours, respectively. The respective durations were 24, 10, and 8 hours. Both nasal and oral bioavailabilities were 0.85. Subjects reported that nasal methadone caused a burning sensation. Nasal administration of methadone results in rapid absorption and onset of effect and high bioavailability, which was greater than that reported for other nasal opioids, with a similar duration of effect. Nasal administration may be an alternative route of methadone administration; however, improved formulations are desirable to reduce nasal irritation.

  4. Nasal-nanotechnology: revolution for efficient therapeutics delivery.

    PubMed

    Kumar, Amrish; Pandey, Aditya Nath; Jain, Sunil Kumar

    2016-01-01

    In recent years, nanotechnology-based delivery systems have gained interest to overcome the problems of restricted absorption of therapeutic agents from the nasal cavity, depending upon the physicochemical properties of the drug and physiological properties of the human nose. The well-tolerated and non-invasive nasal drug delivery when combined with the nanotechnology-based novel formulations and carriers, opens the way for the effective systemic and brain targeting delivery of various therapeutic agents. To accomplish competent drug delivery, it is imperative to recognize the interactions among the nanomaterials and the nasal biological environment, targeting cell-surface receptors, drug release, multiple drug administration, stability of therapeutic agents and molecular mechanisms of cell signaling involved in patho-biology of the disease under consideration. Quite a few systems have been successfully formulated using nanomaterials for intranasal (IN) delivery. Carbon nanotubes (CNTs), chitosan, polylactic-co-glycolic acid (PLGA) and PLGA-based nanosystems have also been studied in vitro and in vivo for the delivery of several therapeutic agents which shown promising concentrations in the brain after nasal administration. The use of nanomaterials including peptide-based nanotubes and nanogels (NGs) for vaccine delivery via nasal route is a new approach to control the disease progression. In this review, the recent developments in nanotechnology utilized for nasal drug delivery have been discussed.

  5. Nasal septal angiofibroma, a subclass of extranasopharyngeal angiofibroma.

    PubMed

    Garcia-Rodriguez, Laura; Rudman, Kelli; Cogbill, Christopher H; Loehrl, Todd; Poetker, David M

    2012-01-01

    Extranasopharyngeal angiofibromas (ENA) arising from the nasal septum or nasal septal angiofibromas are extremely rare; only 13 such cases have been reported in the international literature. Our objective is to describe the presentation, workup, and surgical management of these lesions. Case reports were done. The setting was a tertiary care referral center and the Veterans Affairs Medical Center. PATIENTS, INTERVENTIONS, AND RESULTS: We present 2 cases of extranasopharyngeal angiofibroma occurring on the nasal septum. In this report, we discuss the occurrence, the histopathologic findings, and the treatment of nasal septal angiofibroma. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Nasal Anatomy

    MedlinePlus

    ... below. The nasal cavity is surrounded by paired, air-filled chambers on each side, and these lie towards the ... and left “choana” and open into a common chamber called the ... When we breathe in, air travels through the nostril, through the right and ...

  7. Nasal hydropulsion: a novel tumor biopsy technique.

    PubMed

    Ashbaugh, Elizabeth A; McKiernan, Brendan C; Miller, Carrie J; Powers, Barbara

    2011-01-01

    Intranasal tumors of dogs and cats pose a diagnostic and therapeutic challenge for small animal practitioners. Multiple nasal biopsy techniques have been described in the past. This report describes a simplified flushing technique to biopsy and debulk nasal tumors, which often also results in immediate clinical relief for the patient. Based on the results of this retrospective study, the authors recommend high-pressure saline hydropulsion as a minimally invasive diagnostic, and potentially therapeutic, technique for nasal tumors in dogs and cats.

  8. Nasal aesthetics: a cross-cultural analysis.

    PubMed

    Broer, Peter N; Buonocore, Samuel; Morillas, Angie; Liu, Jong; Tanna, Neil; Walker, Marc; Ng, Reuben; Ng, Ruben; Persing, John A

    2012-12-01

    Plastic surgeons often approach nasal aesthetic evaluation with the aid of seemingly objective measurements. However, ideal measurements of an attractive nose, as suggested in the literature, might not apply on a cross-cultural basis. Given these controversies, this study aimed to investigate the cultural and ethnic impact on nasal shape preferences. Computerized images of a model's nose were generated in which the nasal width, root, tip, dorsum, and projection of the lips and chin could be altered. A survey containing these images was sent to over 13,000 plastic surgeons and lay people in 50 different countries, with a total response rate of 9.6 percent. Demographic information about the interviewees was obtained. Preferred dimensions of the nose were broken down according to geographic, ethnic, occupational, and sex variables. Interregional comparison revealed that plastic surgeons from Latin America and the Caribbean overall prefer smaller and narrower noses, with more projecting tips, lips, and chins. Similar trends hold true when analyzing results from the general public. Significant differences were found comparing preferences between plastic surgeons and the general public. Plastic surgeons preferred wider nasal roots and tips and, in combination, more projected nasal dorsi, tips, lips, and chins. No universal parameter can define ideal aesthetics of the nose across cultures and ethnic backgrounds. As demonstrated, geographic, ethnic, and cultural factors influence aesthetic perceptions of patients and surgeons.

  9. Anatomy of the nasal profile

    PubMed Central

    Anderson, K J; Henneberg, M; Norris, R M

    2008-01-01

    There is a lack in the understanding of the variation within the thickness of the soft tissue structures (muscle, skin and fat) overlying the cartilaginous skeleton of the nose and their relationship to the dorsum shape. We examined such relationships by dissecting noses of six adult female and six adult male cadavers, comparing the internal anatomical structures to the external nasal profile. We found that the soft tissue structures differ in thickness along the dorsum and that these differences are individualized. Specifically, continuous presence of subcutaneous fat from root to tip was found in half the sample, one nose had fat only on the tip, another one only on the root, the four others at both positions. The nasalis muscle was identifiable in nine of the 12 noses, transversing the nose in half the sample, and in the remaining three, only the lateral section of the muscle was identified. The superior border of the septal cartilage does not form a linear extension of the profile contour of the nasal bones but angles downwards. The actual profile contour of the dorsum does not follow the profile of the nasal bones or the septal cartilage. These results may influence the current use of nasal guidelines in forensic facial approximation. PMID:19172735

  10. Factors influencing delivered mean airway pressure during nasal CPAP with the RAM cannula.

    PubMed

    Gerdes, Jeffrey S; Sivieri, Emidio M; Abbasi, Soraya

    2016-01-01

    To measure mean airway pressure (MAP) delivered through the RAM Cannula® when used with a ventilator in CPAP mode as a function of percent nares occlusion in a simulated nasal interface/test lung model and to compare the results to MAPs using a nasal continuous positive airway pressure (NCPAP) interface with nares fully occluded. An artificial airway model was connected to a spontaneous breathing lung model in which MAP was measured at set NCPAP levels between 4 and 8 cmH2 O provided by a Dräger Evita XL® ventilator and delivered through three sizes of RAM cannulae. Measurements were performed with varying leakage at the nasal interface by decreasing occlusion from 100% to 29%, half-way prong insertion, and simulated mouth leakage. Comparison measurements were made using the Dräger BabyFlow® NCPAP interface with a full nasal seal. With simulated mouth closed, the Dräger interface delivered MAPs within 0.5 cmH2 O of set CPAP levels. For the RAM cannula, with 60-80% nares occlusion, overall delivered MAPs were 60 ± 17% less than set CPAP levels (P < 0.001). Further, MAP decreased progressively with decreasing percent nares occlusion. The simulated open mouth condition resulted in significantly lower MAPs to <1.7 cmH2 O. The one-half prong insertion depth condition, with closed mouth, yielded MAPs approximately 35 ± 9% less than full insertion pressures (P < 0.001). In our bench tests, the RAM interface connected to a ventilator in NCPAP mode failed to deliver set CPAP levels when applied using the manufacturer recommended 60-80% nares occlusion, even with closed mouth and full nasal prong insertion conditions. © 2015 Wiley Periodicals, Inc.

  11. NORMAL NASAL GENE EXPRESSION LEVELS USING CDNA ARRAY TECHNOLOGY

    EPA Science Inventory

    Normal Nasal Gene Expression Levels Using cDNA Array Technology.

    The nasal epithelium is a target site for chemically-induced toxicity and carcinogenicity. To detect and analyze genetic events which contribute to nasal tumor development, we first defined the gene expressi...

  12. A combined inspiratory and expiratory muscle training program improves respiratory muscle strength and fatigue in multiple sclerosis.

    PubMed

    Ray, Andrew D; Udhoji, Supriya; Mashtare, Terry L; Fisher, Nadine M

    2013-10-01

    To determine the effects of a short-duration, combined (inspiratory and expiratory), progressive resistance respiratory muscle training (RMT) protocol on respiratory muscle strength, fatigue, health-related quality of life, and functional performance in individuals with mild-to-moderate multiple sclerosis (MS). Quasi-experimental before-after trial. University rehabilitation research laboratory. Volunteers with MS (N=21) were divided into 2 groups: RMT (n=11; 9 women, 2 men; mean age ± SD, 50.9 ± 5.7y, mean Expanded Disability Status Scale score ± SD, 3.2 ± 1.9) and a control group that did not train (n=10; 7 women, 3 men; mean age ± SD, 56.2 ± 8.8y, mean Expanded Disability Status Scale score ± SD, 4.4 ± 2.1). Expanded Disability Status Scale scores ranged from 1 to ≤6.5. No patients withdrew from the study. Training was a 5-week combined progressive resistance RMT program, 3d/wk, 30 minutes per session. The primary outcome measures were maximal inspiratory pressure and expiratory pressure and the Modified Fatigue Impact Scale. All subjects completed secondary measures of pulmonary function, the six-minute walk test, the timed stair climb, the Multiple Sclerosis Self-Efficacy Scale, the Medical Outcomes Study 36-Item Short-Form Health Survey, and the Physical Activity Disability Scale. Maximal inspiratory pressure and expiratory pressure (mean ± SD) increased 35% ± 22% (P<.001) and 26% ± 17% (P<.001), respectively, whereas no changes were noted in the control group (12% ± 23% and -4% ± 17%, respectively). RMT improved fatigue (Modified Fatigue Impact Scale, P<.029), with no change or worsening in the control group. No changes were noted in the six-minute walk test, stair climb, Multiple Sclerosis Self-Efficacy Scale, or Physical Activity Disability Scale in the RMT group. The control group had decreases in emotional well-being and general health (Medical Outcomes Study 36-Item Short-Form Health Survey). A short-duration, combined RMT program

  13. Nasal septum perforation of welders.

    PubMed

    Lee, Choong Ryeol; Yoo, Cheol In; Lee, Ji ho; Kang, Seong Kyu

    2002-07-01

    During the periodic physical checkups in 1997-2000, the authors have found eleven cases of nasal septum perforation among 2,869 welders in Ulsan, Korea. They have not suffered from diseases and conditions that could cause septum perforation such as tuberculosis, syphilis, and long-term use of topical corticosteroids. And also they did not have trauma history and surgical experiences on their nasal septum. To investigate the cause of septum perforation we reviewed the past history of pre-employment, the results of annual working environment survey and the material safety data sheets of welding rods and steels with which they have dealt. We also analyzed the concentration of several metals of welding fume and the concentration of blood and urinary chromium. In the result, we assumed that the nasal septum perforation of welders was due to chronic exposure to low-level hexavalent chromium.

  14. The effects of gas humidification with high-flow nasal cannula on cultured human airway epithelial cells.

    PubMed

    Chidekel, Aaron; Zhu, Yan; Wang, Jordan; Mosko, John J; Rodriguez, Elena; Shaffer, Thomas H

    2012-01-01

    Humidification of inspired gas is important for patients receiving respiratory support. High-flow nasal cannula (HFNC) effectively provides temperature and humidity-controlled gas to the airway. We hypothesized that various levels of gas humidification would have differential effects on airway epithelial monolayers. Calu-3 monolayers were placed in environmental chambers at 37°C with relative humidity (RH) < 20% (dry), 69% (noninterventional comparator), and >90% (HFNC) for 4 and 8 hours with 10 L/min of room air. At 4 and 8 hours, cell viability and transepithelial resistance measurements were performed, apical surface fluid was collected and assayed for indices of cell inflammation and function, and cells were harvested for histology (n = 6/condition). Transepithelial resistance and cell viability decreased over time (P < 0.001) between HFNC and dry groups (P < 0.001). Total protein secretion increased at 8 hours in the dry group (P < 0.001). Secretion of interleukin (IL)-6 and IL-8 in the dry group was greater than the other groups at 8 hours (P < 0.001). Histological analysis showed increasing injury over time for the dry group. These data demonstrate that exposure to low humidity results in reduced epithelial cell function and increased inflammation.

  15. The Effects of Gas Humidification with High-Flow Nasal Cannula on Cultured Human Airway Epithelial Cells

    PubMed Central

    Chidekel, Aaron; Zhu, Yan; Wang, Jordan; Mosko, John J.; Rodriguez, Elena; Shaffer, Thomas H.

    2012-01-01

    Humidification of inspired gas is important for patients receiving respiratory support. High-flow nasal cannula (HFNC) effectively provides temperature and humidity-controlled gas to the airway. We hypothesized that various levels of gas humidification would have differential effects on airway epithelial monolayers. Calu-3 monolayers were placed in environmental chambers at 37°C with relative humidity (RH) < 20% (dry), 69% (noninterventional comparator), and >90% (HFNC) for 4 and 8 hours with 10 L/min of room air. At 4 and 8 hours, cell viability and transepithelial resistance measurements were performed, apical surface fluid was collected and assayed for indices of cell inflammation and function, and cells were harvested for histology (n = 6/condition). Transepithelial resistance and cell viability decreased over time (P < 0.001) between HFNC and dry groups (P < 0.001). Total protein secretion increased at 8 hours in the dry group (P < 0.001). Secretion of interleukin (IL)-6 and IL-8 in the dry group was greater than the other groups at 8 hours (P < 0.001). Histological analysis showed increasing injury over time for the dry group. These data demonstrate that exposure to low humidity results in reduced epithelial cell function and increased inflammation. PMID:22988501

  16. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    PubMed

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise

  17. Infective endocarditis of native valve after anterior nasal packing.

    PubMed

    Jayawardena, Suriya; Eisdorfer, Jacob; Indulkar, Shalaka; Zarkaria, Muhammad

    2006-01-01

    We present a case report of a patient who was previously treated for spontaneous epistaxis with a petroleum jelly gauze (0.5 in x 72 in) anterior nasal packing filled with an antibiotic ointment, along with prophylactic oral clindamycin. The patient presented with fever and hypotension 3 days after the nasal packing. Her blood cultures grew methicillin-resistant Staphylococcus aureus and the transesophageal echocardiography showed vegetation on the atrial surface of the posterior mitral valve leaflet, confirming the diagnosis of bacterial endocarditis attributable to nasal packing. Several case reports discuss toxic shock syndrome after nasal packing, but none describe endocarditis of the native heart valves subsequent to anterior nasal packing. Current guidelines on endocarditis prophylaxis produced by the American Heart Association, European Cardiac Society, and British Cardiac Society together with published evidence do not recommend endocarditis prophylaxis for patients with native heart valves undergoing anterior nasal packing.

  18. Chronic and acute inspiratory muscle loading augment the effect of a 6-week interval program on tolerance of high-intensity intermittent bouts of running.

    PubMed

    Tong, Tom K; Fu, Frank H; Eston, Roger; Chung, Pak-Kwong; Quach, Binh; Lu, Kui

    2010-11-01

    This study examined the hypothesis that chronic (training) and acute (warm-up) loaded ventilatory activities applied to the inspiratory muscles (IM) in an integrated manner would augment the training volume of an interval running program. This in turn would result in additional improvement in the maximum performance of the Yo-Yo intermittent recovery test in comparison with interval training alone. Eighteen male nonprofessional athletes were allocated to either an inspiratory muscle loading (IML) group or control group. Both groups participated in a 6-week interval running program consisting of 3-4 workouts (1-3 sets of various repetitions of selected distance [100-2,400 m] per workout) per week. For the IML group, 4-week IM training (30 inspiratory efforts at 50% maximal static inspiratory pressure [P0] per set, 2 sets·d-1, 6 d·wk-1) was applied before the interval program. Specific IM warm-up (2 sets of 30 inspiratory efforts at 40% P0) was performed before each workout of the program. For the control group, neither IML was applied. In comparison with the control group, the interval training volume as indicated by the repeatability of running bouts at high intensity was approximately 27% greater in the IML group. Greater increase in the maximum performance of the Yo-Yo test (control: 16.9 ± 5.5%; IML: 30.7 ± 4.7% baseline value) was also observed after training. The enhanced exercise performance was partly attributable to the greater reductions in the sensation of breathlessness and whole-body metabolic stress during the Yo-Yo test. These findings show that the combination of chronic and acute IML into a high-intensity interval running program is a beneficial training strategy for enhancing the tolerance to high-intensity intermittent bouts of running.

  19. Nasal valve evaluation in the Mexican-Hispanic (mestizo) nose.

    PubMed

    Jasso-Ramírez, Elizabeth; Sánchez Y Béjar, Fernando; Arcaute Aizpuru, Fernando; Maulen Radován, Irene E; de la Garza Hesles, Héctor

    2018-04-01

    Our aim in this study was to determine the angle of the internal nasal valve in Mexican patients with the "mestizo nose" feature and without nasal obstructive symptoms. The work was prospective, comparative, and observational in nature and included patients >14 years of age who were seen in the Otolaryngology Department at the Los Angeles Lomas Hospital between April and May 2016. The angle of the internal nasal valve was measured in 30 patients without obstructive symptoms. Endoscopic examination was performed with a 0° endoscope framed with tape at a 13-mm distance from the endoscope's tip, and digital photographs of the internal nasal valve were taken. The measurement of the angle of the internal nasal valve was made in sexagesimal degrees using Golden Ratio v3.1 (2012) software. Statistical analysis was performed using Excel v15.13.3. The angles of the internal nasal valve of the patients were (mean ± standard deviation) 24.07 ± 4.8° for the right nasal cavity and 25.07 ± 5.0° for the left nasal cavity, wider than the angle reported in the normal Caucasian nose established in the literature. According to our results, the Mexican-Hispanic mestizo nose has a wider angle in the internal nasal valve than that considered normal in the literature (10°-15°). We believe it is necessary to undertake a second study and add an airflow resistance measurement with a rhinomanometry procedure so we can compare the results with those in the Caucasian population. © 2018 ARS-AAOA, LLC.

  20. A nasal dermoid sinus in an English bull terrier.

    PubMed

    Burrow, R D

    2004-11-01

    A five-year-old, entire female English bull terrier was presented with a six-week history of intermittent facial swelling and nasal pain, following an incident of nasal trauma. A small opening was present at the mucocutaneous junction on the dorsal nasal planum. Examination under general anaesthesia allowed catheterisation of this opening and confirmed the presence of a tract passing caudally. Plain radiographic examination of the region was unremarkable. Positive contrast sinography demonstrated contrast material filling a midline tract that passed caudally and subcutaneously towards the nasal bone. This tract was surgically excised. Histopathological examination of the excised tissue, together with the clinical findings, led to the diagnosis of nasal dermoid sinus.

  1. Effects of topical nasal steroids and diclofenac on the nasal mucosa during hyperbaric oxygen therapy: a double-blind experimental study.

    PubMed

    Vuralkan, Erkan; Cobanoglu, Hatice Bengu; Arslan, Abdullah; Arslan, Selcuk; Mungan, Sevdegul; Tatar, Selcuk; Toklu, Akın Savas

    2014-08-01

    We aimed to evaluate nasal mucosal changes and efficiency of nasal steroids and diclofenac on nasal mucosa during hyperbaric oxygen (HBO) treatment. Forty adult Albino-Wistar rats were randomized into four groups. Group 1 (control group) (n = 10) not exposed to hyperbaric or enhanced oxygen concentrations; group 2 (HBO group) (n = 10) underwent only HBO treatment; group 3 (n = 10) received HBO and intranasal mometasone furoate (10 μl/day); group 4 (n = 10) treated with HBO and diclofenac sodium (10 mg/kg/day ip). Specimens of nasal mucosa were collected after sacrificing and dissection of animals. The specimens were processed for light microscopic evaluation, and then evaluated histopathologically for fibroblastic proliferation and inflammation. Regarding the scores of inflammation, the level of inflammation in the control group was significantly less severe than the other groups (p < 0.05). Evaluation of the fibrosis scores showed that the scores of both groups 2 and 4 were significantly increased (p < 0.05). There were no statistically significant differences between groups 2, 3, and 4 as for fibrosis and inflammation (p > 0.05). Chronic HBO treatment induced mild inflammation of the nasal mucosa. These effects cannot be prevented adequately by administration of nasal steroids and diclofenac.

  2. Relative vascular permeability and vascularity across different regions of the rat nasal mucosa: implications for nasal physiology and drug delivery

    PubMed Central

    Kumar, Niyanta N.; Gautam, Mohan; Lochhead, Jeffrey J.; Wolak, Daniel J.; Ithapu, Vamsi; Singh, Vikas; Thorne, Robert G.

    2016-01-01

    Intranasal administration provides a non-invasive drug delivery route that has been proposed to target macromolecules either to the brain via direct extracellular cranial nerve-associated pathways or to the periphery via absorption into the systemic circulation. Delivering drugs to nasal regions that have lower vascular density and/or permeability may allow more drug to access the extracellular cranial nerve-associated pathways and therefore favor delivery to the brain. However, relative vascular permeabilities of the different nasal mucosal sites have not yet been reported. Here, we determined that the relative capillary permeability to hydrophilic macromolecule tracers is significantly greater in nasal respiratory regions than in olfactory regions. Mean capillary density in the nasal mucosa was also approximately 5-fold higher in nasal respiratory regions than in olfactory regions. Applying capillary pore theory and normalization to our permeability data yielded mean pore diameter estimates ranging from 13–17 nm for the nasal respiratory vasculature compared to <10 nm for the vasculature in olfactory regions. The results suggest lymphatic drainage for CNS immune responses may be favored in olfactory regions due to relatively lower clearance to the bloodstream. Lower blood clearance may also provide a reason to target the olfactory area for drug delivery to the brain. PMID:27558973

  3. Influences of Duration of Inspiratory Effort, Respiratory Mechanics, and Ventilator Type on Asynchrony With Pressure Support and Proportional Assist Ventilation.

    PubMed

    Vasconcelos, Renata S; Sales, Raquel P; Melo, Luíz H de P; Marinho, Liégina S; Bastos, Vasco Pd; Nogueira, Andréa da Nc; Ferreira, Juliana C; Holanda, Marcelo A

    2017-05-01

    Pressure support ventilation (PSV) is often associated with patient-ventilator asynchrony. Proportional assist ventilation (PAV) offers inspiratory assistance proportional to patient effort, minimizing patient-ventilator asynchrony. The objective of this study was to evaluate the influence of respiratory mechanics and patient effort on patient-ventilator asynchrony during PSV and PAV plus (PAV+). We used a mechanical lung simulator and studied 3 respiratory mechanics profiles (normal, obstructive, and restrictive), with variations in the duration of inspiratory effort: 0.5, 1.0, 1.5, and 2.0 s. The Auto-Trak system was studied in ventilators when available. Outcome measures included inspiratory trigger delay, expiratory trigger asynchrony, and tidal volume (V T ). Inspiratory trigger delay was greater in the obstructive respiratory mechanics profile and greatest with a effort of 2.0 s (160 ms); cycling asynchrony, particularly delayed cycling, was common in the obstructive profile, whereas the restrictive profile was associated with premature cycling. In comparison with PSV, PAV+ improved patient-ventilator synchrony, with a shorter triggering delay (28 ms vs 116 ms) and no cycling asynchrony in the restrictive profile. V T was lower with PAV+ than with PSV (630 mL vs 837 mL), as it was with the single-limb circuit ventilator (570 mL vs 837 mL). PAV+ mode was associated with longer cycling delays than were the other ventilation modes, especially for the obstructive profile and higher effort values. Auto-Trak eliminated automatic triggering. Mechanical ventilation asynchrony was influenced by effort, respiratory mechanics, ventilator type, and ventilation mode. In PSV mode, delayed cycling was associated with shorter effort in obstructive respiratory mechanics profiles, whereas premature cycling was more common with longer effort and a restrictive profile. PAV+ prevented premature cycling but not delayed cycling, especially in obstructive respiratory mechanics

  4. Triamcinolone Nasal Spray

    MedlinePlus

    ... An adult should help children under 12 years old to use triamcinolone nasal spray. Children younger than ... This branded product is no longer on the market. Generic alternatives may be available.

  5. Total Nasal Reconstruction for Extruded, Pending Extrusion and Severely Displaced Silicone Nasal Implants in Asian Patients.

    PubMed

    Hodgkinson, Darryl J

    2017-04-01

    The Australian population is 10% of Asian origin, and many of our Asian patients have had nasal augmentation using prosthetic material prior to immigration or as medical tourists back in their country of origin. Insertion of nasal prostheses is the most common way to augment the nasal dorsum in the Asian patient and although there is a trend towards autogenous primary augmentation still, the vast majority of patients seen in clinical practice have had augmentation by the insertion of foreign material generally silicone. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  6. Evaluation of the effect of localized skin cooling on nasal airway volume by acoustic rhinometry.

    PubMed

    Yamagiwa, M; Hilberg, O; Pedersen, O F; Lundqvist, G R

    1990-04-01

    Ten healthy subjects (four men and six women) were subjected to localized skin cooling by submersion for 5 min of both feet and, in another experiment, one hand and forearm into ice-cold water. Repeated measurements of nasal cavity volumes by a new method, acoustic rhinometry, showed characteristic patterns ranging from marked increases in volumes lasting the entire exposure period to transient monophasic or biphasic responses to no change at all. The pattern in individual subjects was reproducible with the two methods of cooling, and it could be characterized by five types when related to baseline measurements during the preexposure period. Because of large minute-to-minute variations, probably determined by local differences and fluctuations in blood flow in tissues through the nose, evaluation of induced changes in the nasal cavity volume cannot be based on single measurements as has frequently been done in the past by using rhinomanometry as the experimental method. The mechanisms behind the characteristic patterns in immediate human nasal response to local skin cooling challenge remains to be explored.

  7. Triclosan Promotes Staphylococcus aureus Nasal Colonization

    PubMed Central

    Syed, Adnan K.; Ghosh, Sudeshna; Love, Nancy G.; Boles, Blaise R.

    2014-01-01

    ABSTRACT The biocide triclosan is used in many personal care products, including toothpastes, soaps, clothing, and medical equipment. Consequently, it is present as a contaminant in the environment and has been detected in some human fluids, including serum, urine, and milk. Staphylococcus aureus is an opportunistic pathogen that colonizes the noses and throats of approximately 30% of the population. Colonization with S. aureus is known to be a risk factor for several types of infection. Here we demonstrate that triclosan is commonly found in the nasal secretions of healthy adults and the presence of triclosan trends positively with nasal colonization by S. aureus. We demonstrate that triclosan can promote the binding of S. aureus to host proteins such as collagen, fibronectin, and keratin, as well as inanimate surfaces such as plastic and glass. Lastly, triclosan-exposed rats are more susceptible to nasal colonization with S. aureus. These data reveal a novel factor that influences the ability of S. aureus to bind surfaces and alters S. aureus nasal colonization. PMID:24713325

  8. Respiratory complications from nasal packing: systematic review.

    PubMed

    Rotenberg, Brian; Tam, Samantha

    2010-10-01

    Patients with posterior nasal packing are thought to be at high risk for the development of respiratory complications. Controversy exists regarding the evidence in that regard; consequently, the level of vital sign monitoring required for these patients is unclear. The objective of this article is to systematically review the literature describing respiratory complications from nasal packing. Literature published before July 2009 on Medline and Embase was eligible for inclusion. Original research and review articles whose major topic was nasal packing for epistaxis were included. Nonhuman studies and studies not published in English were excluded. Studies were evaluated for quality using a modified Downs and Black scale. Data regarding respiratory complications of nasal packing were extracted and summarized. Of the 262 studies retrieved, 14 met inclusion criteria (7 case series, 3 cohort studies, and 4 reviews). Six studies discussed pulmonary mechanics, three discussed sleep apnea, two reviews described complications of nasal packing, and three articles focused on the treatment of posterior epistaxis. There was a lack of high-quality literature describing adverse respiratory events following posterior packing. The literature regarding development of respiratory complications from posterior packing is mostly based on expert opinion or case series. There is some suggestion that sleep apnea may develop after placement posterior nasal packing, but the severity appears to be mild. Evidence is lacking to support the contention that all patients with posterior packing are at risk for developing adverse respiratory events or require admission to a monitored setting.

  9. Nasal Involvement in Obstructive Sleep Apnea Syndrome

    PubMed Central

    Michels, Daniel de Sousa; Rodrigues, Amanda da Mota Silveira; Nakanishi, Márcio; Sampaio, André Luiz Lopes; Venosa, Alessandra Ramos

    2014-01-01

    Numerous studies have reported an association between nasal obstruction and obstructive sleep apnea syndrome (OSAS), but the precise nature of this relationship remains to be clarified. This paper aimed to summarize data and theories on the role of the nose in the pathophysiology of sleep apnea as well as to discuss the benefits of surgical and medical nasal treatments. A number of pathophysiological mechanisms can potentially explain the role of nasal pathology in OSAS. These include the Starling resistor model, the unstable oral airway, the nasal ventilatory reflex, and the role of nitric oxide (NO). Pharmacological treatment presents some beneficial effects on the frequency of respiratory events and sleep architecture. Nonetheless, objective data assessing snoring and daytime sleepiness are still necessary. Nasal surgery can improve the quality of life and snoring in a select group of patients with mild OSAS and septal deviation but is not an effective treatment for OSA as such. Despite the conflicting results in the literature, it is important that patients who are not perfectly adapted to CPAP are evaluated in detail, in order to identify whether there are obstructive factors that could be surgically corrected. PMID:25548569

  10. Clinical Effectiveness of High-Flow Nasal Cannula in Hypoxaemic Patients during Bronchoscopic Procedures.

    PubMed

    Chung, Sang Mi; Choi, Ju Whan; Lee, Young Seok; Choi, Jong Hyun; Oh, Jee Youn; Min, Kyung Hoon; Hur, Gyu Young; Lee, Sung Yong; Shim, Jae Jeong; Kang, Kyung Ho

    2018-06-19

    Bronchoscopy is a useful diagnostic and therapeutic tool. However, the clinical use of high-flow nasal cannula (HFNC) in adults with acute respiratory failure for diagnostic and invasive procedures has not been well evaluated. We present our experiences of well-tolerated diagnostic bronchoscopy as well as cases of improved saturation in hypoxaemic patients after a therapeutic bronchoscopic procedure. We retrospectively reviewed data of hypoxaemic patients who had undergone bronchoscopy for diagnostic or therapeutic purposes from October 2015 to February 2017. Ten patients (44-75 years of age) were enrolled. The clinical purposes of bronchoscopy were for diagnosis in seven patients and for intervention in three patients. For the diagnoses, we performed bronchoalveolar lavage in six patients. One patient underwent endobronchial ultrasonography with transbronchial needle aspiration of a lymph node to investigate tumour involvement. Patients who underwent bronchoscopy for therapeutic interventions had endobronchial mass or blood clot removal with cryotherapy for bleeding control. The mean saturation (SpO₂) of pre-bronchoscopy in room air was 84.1%. The lowest and highest mean saturation with HFNC during the procedure was 95% and 99.4, respectively. The mean saturation in room air post-bronchoscopy was 87.4%, which was 3.3% higher than the mean room air SpO₂ pre-bronchoscopy. Seven patients with diagnostic bronchoscopy had no hypoxic event. Three patients with interventional bronchoscopy showed improvement in saturation after the procedure. Bronchoscopy was well tolerated in all 10 cases. This study suggests that the use of HFNC in hypoxaemic patients during diagnostic and therapeutic bronchoscopy procedures has clinical effectiveness. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  11. Piezoelectric sensing: Evaluation for clinical investigation of deviated nasal septum

    PubMed Central

    Manjunatha, Roopa G.; Mahapatra, Roy D.; Dorasala, Srinivas

    2013-01-01

    Noninvasive objective evaluation of nasal airflow is one of the important clinical aspects. The developed polyvinylidene fluoride (PVDF) sensor enables measurement of airflow through each side of the nose using its piezoelectric property. This study was designed to evaluate the diagnostic capability of the PVDF sensor in assessing the deviated nasal septum (DNS). PVDF nasal sensor uses its piezoelectric property to measure the peak-to-peak amplitude (Vp-p) of nasal airflow in both of the nostrils: right nostril (RN) and left nostril (LN), separately and simultaneously. We have compared the results of PVDF nasal sensor, visual analog scale (VAS), and clinician scale for 34 DNS patients and 28 healthy controls. Additionally, the results were further analyzed by receiver operating characteristic curve and correlation between PVDF nasal sensor and VAS in detecting DNS. We found a significant difference in the peak-to-peak amplitude values of the test group and the control group. The correlation between the PVDF nasal sensor measurements and VAS (RN and LN combined) for test group was statistically significant (−0.807; p < 0.001). Sensitivity and specificity of the PVDF nasal sensor measurements in the detection of DNS (RN and LN combined) was 85.3 and 74.4%, respectively, with optimum cutoff value ≤0.34 Vp-p. The developed PVDF nasal sensor is noninvasive and requires less patient efforts. The sensitivity and specificity of the PVDF nasal sensor are reliable. According to our findings, we propose that the said PVDF nasal sensor can be used as a new diagnostic tool to evaluate the DNS in routine clinical practice. PMID:24498519

  12. An acoustic study of nasal consonants in three Central Australian languages.

    PubMed

    Tabain, Marija; Butcher, Andrew; Breen, Gavan; Beare, Richard

    2016-02-01

    This study presents nasal consonant data from 21 speakers of three Central Australian languages: Arrernte, Pitjantjatjara and Warlpiri. The six nasals considered are bilabial /m/, dental /n/, alveolar /n/, retroflex /ɳ/, alveo-palatal /ɲ/, and velar /ŋ/. Nasal formant and bandwidth values are examined, as are the locations of spectral minima. Several differences are found between the bilabial /m/ and the velar /ŋ/, and also the palatal /ɲ/. The remaining coronal nasals /n n ɳ/ are not well differentiated within the nasal murmur, but their average bandwidths are lower than for the other nasal consonants. Broader spectral shape measures (Centre of Gravity and Standard Deviation) are also considered, and comparisons are made with data for stops and laterals in these languages based on the same spectral measures. It is suggested that nasals are not as easily differentiated using the various measures examined here as are stops and laterals. It is also suggested that existing models of nasal consonants do not fully account for the observed differences between the various nasal places of articulation; and that oral formants, in addition to anti-formants, contribute substantially to the output spectrum of nasal consonants.

  13. Nitric oxide-dependent neutrophil recruitment: role in nasal secretion.

    PubMed

    Cardell, L O; Agustí, C; Nadel, J A

    2000-12-01

    Leukotriene B4 (LTB4), an inflammatory mediator, is a potent chemoattractant for neutrophils that plays an important role in nasal secretion via release of elastase. Nitric oxide (NO) is an important modulator of leucocyte-endothelial cell interactions, endogenously produced in large quantities in the paranasal sinuses. To examine the role of NO in LTB4-stimulated nasal secretion. A newly-developed method for isolating and superfusing a nasal segment in dogs was used. Instillation of LTB4 into the nasal segment caused a time-dependent increase in the volume of airway fluid and in the recruitment of neutrophils. N(G)-nitro-L-arginine-methylester (L-NAME), an inhibitor of NO synthase, prevented LTB4-induced neutrophil recruitment and nasal secretion. These studies show that NO modulates LTB4-induced neutrophil recruitment and subsequent fluid secretion in the nose, and they suggest a therapeutic role for NO inhibitors in modulating neutrophil-dependent nasal secretion.

  14. Silicone nasal prosthesis retained by an intranasal stent: a clinical report.

    PubMed

    Goveas, Reiyal; Puttipisitchet, Ongart; Shrestha, Binit; Thaworanunta, Sita; Srithavaj, M L Theerathavaj

    2012-08-01

    Nasal defects after tumor excision can leave a patient functionally and esthetically impaired. Loss of nasal septal cartilage support causes the soft tissue to collapse or undergo stenosis, further compounding the problem. Intranasal stents can be used to maintain the patency of such nasal defects. This clinical report describes the use of an acrylic resin nasal stent bonded to a silicone nasal prosthesis to rehabilitate a patient with a nasal defect. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  15. [Clinical effects of inspiratory muscle training in patients with chronic airflow limitation].

    PubMed

    Lisboa, C; Villafranca, C; Pertuzé, J; Leiva, A; Repetto, P

    1995-09-01

    The clinical role of inspiratory muscle training (IMT) in chronic obstructive pulmonary disease (COPD) has not been established, because data on its clinical effect is scarce and controversial. To further investigate these aspects we studied 20 COPD patients (FEV1 37 +/- 3% P) who were randomly and double blindly trained for 30 minutes a day during 10 weeks using a threshold inspiratory trainer with either 30% (group 1) or 10% (group 2) of PIMax as a training load. The training load was crossed after each patient completed 10 weeks of training. Effects were assessed through changes in PIMax, dyspnea through the transition dyspnea index (ITD) and the respiratory effort with Borg's score. Walking capacity was measured with the six minutes walking distance test (6WD) and depression symptoms with Beck's score. Daily life activities were also assessed. Results showed that after 10 weeks of IMT, PIMax increased in both groups (p < 0.05), dyspnea improved in group 1 as compared to group 2 (p < 0.04), 6WD increased significantly in patients of group 1, who also complained of less dyspnea (p < 0.05). Depression scores fell significantly in group 2. Daily activities improved more in group 1. After the crossover patients in group 1 disclosed a significant deterioration in PIMax whereas group 2 disclosed significant improvements in PIMax, dyspnea and 6WD. We conclude that IMT using a threshold device with 30% PIMax is a useful procedure for the treatment of severe COPD patients.

  16. Nasal inflammation in sleep apnoea patients using CPAP and effect of heated humidification.

    PubMed

    Koutsourelakis, I; Vagiakis, E; Perraki, E; Karatza, M; Magkou, C; Kopaka, M; Roussos, C; Zakynthinos, S

    2011-03-01

    Nasal continuous positive airway pressure (CPAP) can cause undesirable nasal symptoms, such as congestion to obstructive sleep apnoea (OSA) patients, whose symptoms can be attenuated by the addition of heated humidification. However, neither the nature of nasal symptoms nor the effect of heated humidification on nasal pathophysiology and pathology are convincingly known. 20 patients with OSA on nasal CPAP who exhibited symptomatic nasal obstruction were randomised to receive either 3 weeks of CPAP treatment with heated humidification or 3 weeks of CPAP treatment with sham-heated humidification, followed by 3 weeks of the opposite treatment, respectively. Nasal symptom score, nasal resistance, nasal lavage interleukin-6, interleukin-12 and tumour necrosis factor-α and nasal mucosa histopathology were assessed at baseline and after each treatment arm. Heated humidification in comparison with sham-heated humidification was associated with decrease in nasal symptomatology, resistance and lavage cytokines, and attenuation of inflammatory cell infiltration and fibrosis of the nasal mucosa. In conclusion, nasal obstruction of OSA patients on CPAP treatment is inflammatory in origin and the addition of heated humidification decreases nasal resistance and mucosal inflammation.

  17. An experimental study on the impacts of inspiratory and expiratory muscles activities during mechanical ventilation in ARDS animal model

    PubMed Central

    Zhang, Xianming; Du, Juan; Wu, Weiliang; Zhu, Yongcheng; Jiang, Ying; Chen, Rongchang

    2017-01-01

    In spite of intensive investigations, the role of spontaneous breathing (SB) activity in ARDS has not been well defined yet and little has been known about the different contribution of inspiratory or expiratory muscles activities during mechanical ventilation in patients with ARDS. In present study, oleic acid-induced beagle dogs’ ARDS models were employed and ventilated with the same level of mean airway pressure. Respiratory mechanics, lung volume, gas exchange and inflammatory cytokines were measured during mechanical ventilation, and lung injury was determined histologically. As a result, for the comparable ventilator setting, preserved inspiratory muscles activity groups resulted in higher end-expiratory lung volume (EELV) and oxygenation index. In addition, less lung damage scores and lower levels of system inflammatory cytokines were revealed after 8 h of ventilation. In comparison, preserved expiratory muscles activity groups resulted in lower EELV and oxygenation index. Moreover, higher lung injury scores and inflammatory cytokines levels were observed after 8 h of ventilation. Our findings suggest that the activity of inspiratory muscles has beneficial effects, whereas that of expiratory muscles exerts adverse effects during mechanical ventilation in ARDS animal model. Therefore, for mechanically ventilated patients with ARDS, the demands for deep sedation or paralysis might be replaced by the strategy of expiratory muscles paralysis through epidural anesthesia. PMID:28230150

  18. Dosimetry of nasal uptake of soluble and reactive gases: A first study of inter-human variability (Journal Article)

    EPA Science Inventory

    Anatomically accurate human child and adult nasal tract models will be used in concert with computationally simulated air flow information to investigate the influence of age-related differences in anatomy on inhalation dosimetry in the upper and lower airways. The findings of t...

  19. Effect of nasal deviation on quality of life.

    PubMed

    de Lima Ramos, Sueli; Hochman, Bernardo; Gomes, Heitor Carvalho; Abla, Luiz Eduardo Felipe; Veiga, Daniela Francescato; Juliano, Yara; Dini, Gal Moreira; Ferreira, Lydia Masako

    2011-07-01

    Nasal deviation is a common complaint in otorhinolaryngology and plastic surgery. This condition not only causes impairment of nasal function but also affects quality of life, leading to psychological distress. The subjective assessment of quality of life, as an important aspect of outcomes research, has received increasing attention in recent decades. Quality of life is measured using standardized questionnaires that have been tested for reliability, validity, and sensitivity. The aim of this study was to evaluate health-related quality of life, self-esteem, and depression in patients with nasal deviation. Sixty patients were selected for the study. Patients with nasal deviation (n = 32) were assigned to the study group, and patients without nasal deviation (n = 28) were assigned to the control group. The diagnosis of nasal deviation was made by digital photogrammetry. Quality of life was assessed using the Medical Outcomes Study 36-Item Short Form Health Survey questionnaire; the Rosenberg Self-Esteem/Federal University of São Paulo, Escola Paulista de Medicina Scale; and the 20-item Self-Report Questionnaire. There were significant differences between groups in the physical functioning and general health subscales of the Medical Outcomes Study 36-Item Short Form Health Survey (p < 0.05). Depression was detected in 11 patients (34.4 percent) in the study group and in two patients in the control group, with a significant difference between groups (p < 0.05). Nasal deviation is an aspect of rhinoplasty of which the surgeon should be aware so that proper psychological diagnosis can be made and suitable treatment can be planned because psychologically the patients with nasal deviation have significantly worse quality of life and are more prone to depression. Risk, II.(Figure is included in full-text article.).

  20. Pharmacokinetics of a new, nasal formulation of naloxone.

    PubMed

    Tylleskar, Ida; Skulberg, Arne Kristian; Nilsen, Turid; Skarra, Sissel; Jansook, Phatsawee; Dale, Ola

    2017-05-01

    Nasal naloxone is wanted for bystander administration in opioid overdose and as a needle-free alternative for emergency medical personnel. Epidemiologic studies have indicated a therapeutic effect of bystander administration of low-concentration/high-volume formulations. The objective for this study was to describe the nasal pharmacokinetics of a new high-concentration/low-volume nasal formulation of naloxone. This was an open, randomized triple crossover trial in healthy, human volunteers (n = 12) where two doses of nasal naloxone (0.8 and 1.6 mg) and one intravenous dose (1.0 mg) were compared. Fifteen serum samples were collected before and until 6 h after naloxone administration. Quantification of naloxone was performed by a validated liquid chromatography-tandem mass spectrometry method. Bioavailability was 0.54 (0.45-0.63) for the 0.8 mg and 0.52 (0.37-0.67) for the 1.6 mg nasal naloxone formulation. Maximum concentration levels (C max ) were 1.45 ng/ml (1.07-1.84) for 0.8 mg and 2.57 ng/ml (1.49-3.66) for the 1.6 mg. Time to maximum concentrations (T max ) were reached at 17.9 min (11.4-24.5) and 18.6 min (14.4-22.9) for the 0.8 mg and the 1.6 mg doses, respectively. This nasal naloxone formulation had a rapid, systemic uptake and higher bioavailability than naloxone formulations not designed for IN use. This indicates that an optimized high-concentration/low-volume nasal spray formulation may deliver a therapeutic dose. The 1.6 mg nasal dose provided serum concentrations that surpassed those of 1.0 mg IV after 15-20 min and stayed above for the rest of the study period.

  1. Fentanyl Nasal Spray

    MedlinePlus

    Fentanyl nasal spray is used to treat breakthrough pain (sudden episodes of pain that occur despite round ... effects of the medication) to narcotic pain medications. Fentanyl is in a class of medications called narcotic ( ...

  2. Nasal corticosteroid sprays

    MedlinePlus

    ... effects may include any of these symptoms: Dryness, burning, or stinging in the nasal passage.You can ... or your child uses the spray exactly as prescribed to avoid side effects. If you or your ...

  3. Fluticasone Nasal Spray

    MedlinePlus

    ... you are giving fluticasone nasal spray to a child, you will begin treatment with a lower dose ... the medication and increase the dose if the child's symptoms do not improve. Decrease the dose when ...

  4. Budesonide Nasal Spray

    MedlinePlus

    ... you are giving budesonide nasal spray to a child, you will begin treatment with a lower dose ... the medication and increase the dose if the child's symptoms do not improve. Decrease the dose when ...

  5. Inspiratory and expiratory respiratory muscle training as an adjunct to concurrent strength and endurance training provides no additional 2000 m performance benefits to rowers.

    PubMed

    Bell, Gordon J; Game, Alex; Jones, Richard; Webster, Travis; Forbes, Scott C; Syrotuik, Dan

    2013-01-01

    The purpose of this study was to examine respiratory muscle training (RMT) combined with 9 weeks of resistance and endurance training on rowing performance and cardiopulmonary responses. Twenty-seven rowers (mean ± SD: age = 27 ± 9 years; height = 176.9 ± 10.8 cm; and body mass = 76.1 ± 12.6 kg) were randomly assigned to an inspiratory only (n = 13) or expiratory only (n = 14) training group. Both RMT programs were 3 sets of 10 reps, 6 d/wk in addition to an identical 3 d/wk resistance and 3 d/wk endurance training program. Both groups showed similar improvements in 2000 m rowing performance, cardiorespiratory fitness, strength, and maximum inspiratory (PImax) and expiratory (PEmax) pressures (p < .05). It was concluded that there were no additional benefits of 9 weeks of inspiratory or expiratory RMT on simulated 2000 m rowing performance or cardiopulmonary responses when combined with resistance and endurance training in rowers.

  6. Nasal aerodynamics protects brain and lung from inhaled dust in subterranean diggers, Ellobius talpinus

    PubMed Central

    Moshkin, M. P.; Petrovski, D. V.; Akulov, A. E.; Romashchenko, A. V.; Gerlinskaya, L. A.; Ganimedov, V. L.; Muchnaya, M. I.; Sadovsky, A. S.; Koptyug, I. V.; Savelov, A. A.; Troitsky, S. Yu; Moshkn, Y. M.; Bukhtiyarov, V. I.; Kolchanov, N. A.; Sagdeev, R. Z.; Fomin, V. M.

    2014-01-01

    Inhalation of air-dispersed sub-micrometre and nano-sized particles presents a risk factor for animal and human health. Here, we show that nasal aerodynamics plays a pivotal role in the protection of the subterranean mole vole Ellobius talpinus from an increased exposure to nano-aerosols. Quantitative simulation of particle flow has shown that their deposition on the total surface of the nasal cavity is higher in the mole vole than in a terrestrial rodent Mus musculus (mouse), but lower on the olfactory epithelium. In agreement with simulation results, we found a reduced accumulation of manganese in olfactory bulbs of mole voles in comparison with mice after the inhalation of nano-sized MnCl2 aerosols. We ruled out the possibility that this reduction is owing to a lower transportation from epithelium to brain in the mole vole as intranasal instillations of MnCl2 solution and hydrated nanoparticles of manganese oxide MnO · (H2O)x revealed similar uptake rates for both species. Together, we conclude that nasal geometry contributes to the protection of brain and lung from accumulation of air-dispersed particles in mole voles. PMID:25143031

  7. [Clinal analysis of 202 nasal bone fractures cases].

    PubMed

    Zhong, Zhenhua; Fan, Xihui; Lian, Zhuang; Cheng, Zexing; Zhuang, Yuanling

    2014-12-01

    To evaluate the age, sex, etiology, diagnosis and treatment time of nasal bone fractures. Clinical data of 202 cases with nasal bone fractures treated in the hospital were retrospectively analysed. A total of 202 cases,163 men (80. 7%) and 39 women (19. 3%). Fifty-two patients had a relationship with alcohol consumption, and all of them were males. The most frequent reasons of the injury were fight 46. 5% (94 cases) followed by falling-down 21. 3% (43 cases), traffic accidents 19. 3% (39 cases), works related 6. 5% (13 cases), sport injuries 5. 9% (12 cases) and others 0. 5% (1 cases). Patients distribution in seasons were: spring 54 cases (26.7%), summer 42 cases (20.8%), autumn 58 cases (28.7%), winter 48 cases (23. 8%). Diagnosis of nasal bone fractures were made positively by x-ray films in 79. 7% of cases, but 100% by CT. Positive predictive value of CT was superior to that of X-ray films in the diagnosis of nasal bone fracture. High morbidity of nasal bone fracture was seen in the age group of 20-29 years, and predominantly in male. Fight was found to be the main etiologic factor. We think that CT is necessary for diagnosing nasal bone fracture.

  8. Effect of Breathe Right nasal strip on snoring.

    PubMed

    Ulfberg, J; Fenton, G

    1997-06-01

    Snoring is a significant problem both for the patient and for the bedpartner. It is well known that nasal stuffiness can contribute to snoring, and sleep quality may deteriorate because of the snoring. Nasal dilation can reduce snoring and improve sleep. Thirty-five habitual snorers (18 female, 17 male) and their bedpartners participated in an open label study. The patients were diagnosed as heavy snorers after they underwent overnight polysomnography showing that their apnoea indexes were below 5, thus sleep apnoea patients were not included in the study. The participants and their partners filled out evaluations concerning snoring intensity, mouth dryness and Epworth Sleepiness Scale prior to and after using Breath Right nasal strips for 14 consecutive nights. The Breathe Right external nasal dilator is a simple, nonpharmaceutical method to decrease nasal airway resistance and thus potentially reduce or eliminate snoring. After using the strips there were statistically significant decreases in snoring (p < 0.001) as graded by the bed partner, and in mouth dryness (p = 0.025) and in the Epworth Sleepiness Scale scores (p = 0.001), as graded by the patient. The results of this study indicate that Breathe Right nasal strips may be used to reduce snoring, mouth dryness and sleepiness in patients presenting with symptoms of snoring.

  9. 5-Oxo-ETE from Nasal Epithelial Cells Upregulates Eosinophil Cation Protein by Eosinophils in Nasal Polyps in vitro.

    PubMed

    Lin, Lin; Chen, Zheng; Tang, Xinyue; Dai, Fei; Wei, Jinjin; Sun, Guangbin

    2018-06-13

    5-Oxo-6,8,11,14-eicosatetraenoic acid (5-oxo-ETE) is a potent eosinophil chemoattractant and activator that is synthesized not only in inflammatory cells but also in bronchial epithelial cells. The purpose of this study is to clarify whether 5-oxo-ETE can promote the production of eosinophil cation protein (ECP) by eosinophils in nasal polyps (NP) in vitro, and whether normal nasal epithelial cells can produce this lipid mediator in response to oxidative stress. Nasal biopsy samples were obtained from normal subjects or subjects with chronic rhinosinusitis with NP. The infiltration of eosinophil in NP was detected and cultured. After that, concentrations of ECP in eosinophil and NP cultures were evaluated after the treatment of 5-oxo-ETE or 5-oxo-ETE + its receptor (OXER) antagonist, pertussis toxin (PT). Then we studied the synthesis of 5-oxo-ETE after H2O2 stimulation by normal nasal epithelial cells and by epithelial cells of NP alone in the cultures, and also determined the OXER expression in NP. The number of infiltrative eosinophils in NP was increased. The ECP levels in eosinophil and NP cultures were enhanced after the administration of 5-oxo-ETE, and decreased by the PT treatment. 5-Oxo-ETE was upregulated in the cultures of nasal epithelial cells in the presence of H2O2 and of NP epithelial cells alone. The OXER was expressed in inflammatory cells, and not in epithelial cells. 5-Oxo-ETE produced by nasal epithelial cells may play a role in the formation and development of NP. © 2018 S. Karger AG, Basel.

  10. Expiratory flow limitation relates to symptoms during COPD exacerbations requiring hospital admission.

    PubMed

    Jetmalani, Kanika; Timmins, Sophie; Brown, Nathan J; Diba, Chantale; Berend, Norbert; Salome, Cheryl M; Wen, Fu-Qiang; Chen, Peng; King, Gregory G; Farah, Claude S

    2015-01-01

    Expiratory flow limitation (EFL) is seen in some patients presenting with a COPD exacerbation; however, it is unclear how EFL relates to the clinical features of the exacerbation. We hypothesized that EFL when present contributes to symptoms and duration of recovery during a COPD exacerbation. Our aim was to compare changes in EFL with symptoms in subjects with and without flow-limited breathing admitted for a COPD exacerbation. A total of 29 subjects with COPD were recruited within 48 hours of admission to West China Hospital for an acute exacerbation. Daily measurements of post-bronchodilator spirometry, resistance, and reactance using the forced oscillation technique and symptom (Borg) scores until discharge were made. Flow-limited breathing was defined as the difference between inspiratory and expiratory respiratory system reactance (EFL index) greater than 2.8 cmH2O·s·L(-1). The physiological predictors of symptoms during recovery were determined by mixed-effect analysis. Nine subjects (31%) had flow-limited breathing on admission despite similar spirometry compared to subjects without flow-limited breathing. Spirometry and resistance measures did not change between enrolment and discharge. EFL index values improved in subjects with flow-limited breathing on admission, with resolution in four patients. In subjects with flow-limited breathing on admission, symptoms were related to inspiratory resistance and EFL index values. In subjects without flow-limited breathing, symptoms related to forced expiratory volume in 1 second/forced vital capacity. In the whole cohort, EFL index values at admission was related to duration of stay (Rs=0.4, P=0.03). The presence of flow-limited breathing as well as abnormal respiratory system mechanics contribute independently to symptoms during COPD exacerbations.

  11. Nasalance Scores of Children with Repaired Cleft Palate Who Exhibit Normal Velopharyngeal Closure during Aerodynamic Testing

    ERIC Educational Resources Information Center

    Zajac, David J.

    2013-01-01

    Purpose: To determine if children with repaired cleft palate and normal velopharyngeal (VP) closure as determined by aerodynamic testing exhibit greater acoustic nasalance than control children without cleft palate. Method: Pressure-flow procedures were used to identify 2 groups of children based on VP closure during the production of /p/ in the…

  12. Noise exposure is increased with neonatal helmet CPAP in comparison with conventional nasal CPAP.

    PubMed

    Trevisanuto, D; Camiletti, L; Doglioni, N; Cavallin, F; Udilano, A; Zanardo, V

    2011-01-01

    in adults, noninvasive ventilation via a helmet is associated with significantly greater noise than nasal and facial masks. We hypothesized that noise exposure could be increased with neonatal helmet continuous positive airway pressure (CPAP) in comparison with conventional nasal CPAP (nCPAP). Our primary objective was to compare the noise intensity produced by a neonatal helmet CPAP and a conventional nCPAP system. Furthermore, we aimed to evaluate the effect of the gas flow rate and the presence of the humidifier and the filter on noise levels during neonatal helmet CPAP treatment. in this bench study, noise intensity was measured in the following settings: helmet CPAP, nCPAP, incubator and the neonatal intensive care unit. In helmet CPAP, noise measurements were performed at different gas flow rates (8, 10 and 12 l/min), while in nCPAP, the flow rate was 8 l/min. For both CPAP systems, the level of pressure was maintained constant at 5 cmH(2) O. during neonatal helmet CPAP, the median (interquartile range) noise levels were significantly higher than those during nCPAP: 70.0 dB (69.9-70.4) vs. 62.7 dB (62.5-63.0); P<0.001. In the helmet CPAP, the noise intensities changed with increasing flow rate and with the presence of a humidifier or a filter. noise intensities generated by the neonatal helmet CPAP were significantly higher than those registered while using a conventional nCPAP system. In the helmet, the noise intensity depends on the gas flow rate, and the presence of a humidifier and a filter in the system. 2010 The Acta Anaesthesiologica Scandinavica Foundation.

  13. Dexmedetomidine, high-flow nasal oxygen and sugammadex-reversal of rocuronium: overcoming anaesthetic challenges in a parturient with congenital muscular dystrophy presenting for caesarean section.

    PubMed

    Creaney, M; Moriarty, R M; Milner, M; Murphy, C

    2018-05-01

    Congenital muscular dystrophies are characterised by progressive skeletal muscle weakness from birth or early infancy. Maternal respiratory compromise, joint contractures and presence of spinal instrumentation or fusion are some of the anaesthetic challenges that may be encountered in the obstetric setting. The choice of anaesthetic technique for surgical delivery needs to be considered on an individual basis. Multidisciplinary involvement is paramount to optimise peripartum care and outcomes. In this case report, we present the use of dexmedetomidine, humidified high-flow nasal oxygen, rocuronium and sugammadex in the anaesthetic management of a wheelchair-bound, non-invasive bilevel positive airway pressure ventilation-dependent parturient with congenital muscular dystrophy, who was presenting for caesarean section. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Corrective Septorhinoplasty in Acute Nasal Bone Fractures.

    PubMed

    Kim, Jisung; Jung, Hahn Jin; Shim, Woo Sub

    2018-03-01

    Closed reduction is generally recommended for acute nasal bone fractures, and rhinoplasty is considered in cases with an unsatisfactory outcome. However, concomitant rhinoplasty with fracture reduction might achieve better surgical outcomes. This study investigated the surgical techniques and outcomes in patients who underwent rhinoplasty and fracture reduction concomitantly, during the acute stage of nasal bone fracture. Forty-five patients who underwent concomitant rhinoplasty and fracture reduction were enrolled. Nasal bone fractures were classified into three major types (type I, simple fracture; type II, fracture line that mimics nasal osteotomy; and type III, comminuted fracture) based on computed tomography images and preoperative facial images. Two independent otolaryngology-head and neck surgeons evaluated the surgical outcomes and telephone based survey were made to evaluate patients satisfaction. Among 45 patients, there were 39 males and 6 females. Type I was the commonest type of fracture with 18 patients (40%), while the most frequently used surgical technique for corrective surgery was dorsal augmentation with 44 patients (97.8%). The mean visual analogue scale satisfaction score of the surgeons and patients were 7.62 and 8, respectively, with no significant differences between fracture types. Concomitant rhinoplasty with fracture reduction can be performed for acute nasal bone fracture patients, and it might lead to better aesthetic outcomes.

  15. Analyses and treatments of postoperative nasal complications after endonasal transsphenoidal resection of pituitary neoplasms

    PubMed Central

    Cheng, You; Xue, Fei; Wang, Tian-You; Ji, Jun-Feng; Chen, Wei; Wang, Zhi-Yi; Xu, Li; Hang, Chun-Hua; Liu, Xin-Feng

    2017-01-01

    Abstract In this study, we analyze and discuss the treatments of postoperative nasal complications after endonasal transsphenoidal resection of pituitary neoplasms (PNs). We performed 129 endonasal transsphenoidal resections of PNs and analyzed and treated cases with nasal complications. After endonasal transsphenoidal resection of PNs, there were 26 cases of postoperative nasal complications (20.1%), including nasal hemorrhage (4.8%), cerebrospinal fluid rhinorrhea (6.9%), sphenoid sinusitis (2.3%), atrophic rhinitis (1.6%), olfactory disorder (1.6%), perforation of nasal septum (0.8%), and nasal adhesion (2.3%). All patients clinically recovered after therapy, which included treatment of the cavity through nasal endoscopy, intranasal corticosteroids, and nasal irrigation. We propose that regular nasal endoscopic review, specific nasal medications, and regular nasal irrigation can effectively clear nasal mucosal hyperemia-induced edema and nasal/nasoantral secretions, as well as promote regeneration of nasal mucosa, prevent nasal adhesion, maintain the sinus cavity drainage, and accelerate the recovery of the physiological function of the paranasal sinus. Timely treatment of patients with nasal complications after endonasal transsphenoidal resections of PNs could greatly relieve the clinical symptoms. Nasal cleaning is very beneficial to patients after surgery recovery. PMID:28403108

  16. Marine Collagen Scaffolds for Nasal Cartilage Repair: Prevention of Nasal Septal Perforations in a New Orthotopic Rat Model Using Tissue Engineering Techniques

    PubMed Central

    Bermueller, Christian; Elsaesser, Alexander F.; Sewing, Judith; Baur, Nina; von Bomhard, Achim; Scheithauer, Marc; Notbohm, Holger; Rotter, Nicole

    2013-01-01

    Autologous grafts are frequently needed for nasal septum reconstruction. Because they are only available in limited amounts, there is a need for new cartilage replacement strategies. Tissue engineering based on the use of autologous chondrocytes and resorbable matrices might be a suitable option. So far, an optimal material for nasal septum reconstruction has not been identified. The aim of our study was to provide the first evaluation of marine collagen for use in nasal cartilage repair. First, we studied the suitability of marine collagen as a cartilage replacement matrix in the context of in vitro three dimensional cultures by analyzing cell migration, cytotoxicity, and extracellular matrix formation using human and rat nasal septal chondrocytes. Second, we worked toward developing a suitable orthotopic animal model for nasal septum repair, while simultaneously evaluating the biocompatibility of marine collagen. Seeded and unseeded scaffolds were transplanted into nasal septum defects in an orthotopic rat model for 1, 4, and 12 weeks. Explanted scaffolds were histologically and immunohistochemically evaluated. Scaffolds did not induce any cytotoxic reactions in vitro. Chondrocytes were able to adhere to marine collagen and produce cartilaginous matrix proteins, such as collagen type II. Treating septal cartilage defects in vivo with seeded and unseeded scaffolds led to a significant reduction in the number of nasal septum perforations compared to no replacement. In summary, we demonstrated that marine collagen matrices provide excellent properties for cartilage tissue engineering. Marine collagen scaffolds are able to prevent septal perforations in an autologous, orthotopic rat model. This newly described experimental surgical procedure is a suitable way to evaluate new scaffold materials for their applicability in the context of nasal cartilage repair. PMID:23621795

  17. Systematic review: the influence of nasal obstruction on sleep apnea.

    PubMed

    Migueis, Debora Petrungaro; Thuler, Luiz Claudio Santos; Lemes, Lucas Neves de Andrade; Moreira, Chirlene Santos Souza; Joffily, Lucia; Araujo-Melo, Maria Helena de

    2016-01-01

    Obstructive sleep apnea syndrome (OSAS) is a common disorder that can lead to cardiovascular morbidity and mortality, as well as to metabolic, neurological, and behavioral consequences. It is currently believed that nasal obstruction compromises the quality of sleep when it results in breathing disorders and fragmentation of sleep. However, recent studies have failed to objectively associate sleep quality and nasal obstruction. The aim of this systematic review is to evaluate the influence of nasal obstruction on OSAS and polysomnographic indices associated with respiratory events. Eleven original articles published from 2003 to 2013 were selected, which addressed surgical and non-surgical treatment for nasal obstruction, performing polysomnography type 1 before and after the intervention. In most trials, nasal obstruction was not related to the apnea-hypopnea index (AHI), indicating no improvement in OSAS with reduction in nasal resistance. However, few researchers evaluated other polysomnography indices, such as the arousal index and rapid eye movement (REM) sleep percentage. These could change with nasal obstruction, since it is possible that the nasal obstruction does not completely block the upper airways, but can increase negative intrathoracic pressure, leading to sleep fragmentation. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  18. Interpretation of nasal swab measurements following suspected releases of actinide aerosols

    DOE PAGES

    Klumpp, John Allan; Bertelli, Luiz; Waters, Tom L.

    2017-05-01

    For radionuclides such as plutonium and americium, detection of removable activity in the nose (i.e., nasal swab measurements) are frequently used to determine whether follow-up bioassay measurements are warranted following a potential intake. For this paper, the authors analyzed 429 nasal swab measurements taken following incidents or suspicious circumstances (such as an air monitor alarming) at Los Alamos National Laboratory (LANL) for which the dose was later evaluated using in vitro bioassay. Nasal swab measurements were found to be very poor predictors of dose and should not be used as such in the field. However, nasal swab measurements can bemore » indicative of whether a reliably detectable committed effective dose (CED) occurred. About 14% of nasal swab measurements between 1.25 and 16.7 Bq corresponded to CEDs greater than 1 mSv, so in general, positive nasal swabs always indicate that follow-up bioassay should be performed (positive nasal swabs less than 1.25 Bq are considered separately). This probability increased significantly for nasal swabs greater than 16.7 Bq. Only about 3% of nasal swabs with no detectable activity (NDA) corresponded to reliably detectable CEDs. As a result, a nasal swab with NDA is therefore necessary, but not sufficient, to negate the need for a follow-up bioassay if it was collected following other workplace indicators of a potential intake.« less

  19. Nasal manifestations in chromium industry workers.

    PubMed

    Aiyer, R G; Kumar, Gaurav

    2003-04-01

    People working in mines, plating factories, cement industries are mainly exposed to chrome substances, IIexavalent chromium has been implicated for its toxic effect on the nasal mucosa. Hereby we present a rare study of 28 patients who attended out patient department of Otorhinolaryngology at SSG Hospital, Baroda from a nearby chromium industry. This study aims to present various nasal manifestations of toxic effects of prolonged chromium exposure.

  20. Nasal fracture (image)

    MedlinePlus

    A nasal fracture is a break in the bone over the ridge of the nose. It usually results from a blunt ... and is one of the most common facial fracture. Symptoms of a broken nose include pain, blood ...

  1. Oxygen administration to hypoxic children in Ethiopia: a randomized controlled study comparing complications in the use of nasal prongs with nasopharyngeal catheters.

    PubMed

    Muhe, L; Degefu, H; Worku, B; Oljira, B; Mulholland, E K

    1997-09-01

    Oxygen administration is one of the most important therapeutic interventions for a child with severe acute lower respiratory tract infection (ALRI). Inexpensive and efficient methods of oxygen administration are highly desirable in hospitals in developing countries. The objectives of this study were to compare the frequency and nature of complications when nasopharyngeal catheters or nasal prongs are used to deliver oxygen. One hundred and twenty-one children between the ages of 2 weeks and 5 years with hypoxia due to ALRI were randomized to receive oxygen via a catheter (61 children) or via nasal prongs (60 children). The two groups were similar in terms of diagnoses, clinical severity, oxygen saturation on admission and case fatality rates. There was no difference in the incidence of hypoxaemic episodes between the two groups. The oxygen flow rates required on the day of admission for adequate oxygenation (SaO2 > 90%) ranged from 0.8 litres per minute to 1.2 litres per minute. The required oxygen flow rate decreased during the course of treatment. Mucus production was more of a problem in the catheter group, and nasal blockage, intolerance of the method of oxygen administration and nursing effort were generally higher amongst the catheter group, but none of these differences was significant. Ulceration or bleeding of the nose was significantly more common in the catheter group (19.7% vs 6.7%, p < 0.05). Abdominal distension and nasal perforation were not seen in either group. This study suggests that nasal prongs are safer, more comfortable and require less nursing expertise than nasopharyngeal catheters for administration of oxygen to children.

  2. Peripheral chemoreceptors tune inspiratory drive via tonic expiratory neuron hubs in the medullary ventral respiratory column network.

    PubMed

    Segers, L S; Nuding, S C; Ott, M M; Dean, J B; Bolser, D C; O'Connor, R; Morris, K F; Lindsey, B G

    2015-01-01

    Models of brain stem ventral respiratory column (VRC) circuits typically emphasize populations of neurons, each active during a particular phase of the respiratory cycle. We have proposed that "tonic" pericolumnar expiratory (t-E) neurons tune breathing during baroreceptor-evoked reductions and central chemoreceptor-evoked enhancements of inspiratory (I) drive. The aims of this study were to further characterize the coordinated activity of t-E neurons and test the hypothesis that peripheral chemoreceptors also modulate drive via inhibition of t-E neurons and disinhibition of their inspiratory neuron targets. Spike trains of 828 VRC neurons were acquired by multielectrode arrays along with phrenic nerve signals from 22 decerebrate, vagotomized, neuromuscularly blocked, artificially ventilated adult cats. Forty-eight of 191 t-E neurons fired synchronously with another t-E neuron as indicated by cross-correlogram central peaks; 32 of the 39 synchronous pairs were elements of groups with mutual pairwise correlations. Gravitational clustering identified fluctuations in t-E neuron synchrony. A network model supported the prediction that inhibitory populations with spike synchrony reduce target neuron firing probabilities, resulting in offset or central correlogram troughs. In five animals, stimulation of carotid chemoreceptors evoked changes in the firing rates of 179 of 240 neurons. Thirty-two neuron pairs had correlogram troughs consistent with convergent and divergent t-E inhibition of I cells and disinhibitory enhancement of drive. Four of 10 t-E neurons that responded to sequential stimulation of peripheral and central chemoreceptors triggered 25 cross-correlograms with offset features. The results support the hypothesis that multiple afferent systems dynamically tune inspiratory drive in part via coordinated t-E neurons. Copyright © 2015 the American Physiological Society.

  3. Peripheral chemoreceptors tune inspiratory drive via tonic expiratory neuron hubs in the medullary ventral respiratory column network

    PubMed Central

    Segers, L. S.; Nuding, S. C.; Ott, M. M.; Dean, J. B.; Bolser, D. C.; O'Connor, R.; Morris, K. F.

    2014-01-01

    Models of brain stem ventral respiratory column (VRC) circuits typically emphasize populations of neurons, each active during a particular phase of the respiratory cycle. We have proposed that “tonic” pericolumnar expiratory (t-E) neurons tune breathing during baroreceptor-evoked reductions and central chemoreceptor-evoked enhancements of inspiratory (I) drive. The aims of this study were to further characterize the coordinated activity of t-E neurons and test the hypothesis that peripheral chemoreceptors also modulate drive via inhibition of t-E neurons and disinhibition of their inspiratory neuron targets. Spike trains of 828 VRC neurons were acquired by multielectrode arrays along with phrenic nerve signals from 22 decerebrate, vagotomized, neuromuscularly blocked, artificially ventilated adult cats. Forty-eight of 191 t-E neurons fired synchronously with another t-E neuron as indicated by cross-correlogram central peaks; 32 of the 39 synchronous pairs were elements of groups with mutual pairwise correlations. Gravitational clustering identified fluctuations in t-E neuron synchrony. A network model supported the prediction that inhibitory populations with spike synchrony reduce target neuron firing probabilities, resulting in offset or central correlogram troughs. In five animals, stimulation of carotid chemoreceptors evoked changes in the firing rates of 179 of 240 neurons. Thirty-two neuron pairs had correlogram troughs consistent with convergent and divergent t-E inhibition of I cells and disinhibitory enhancement of drive. Four of 10 t-E neurons that responded to sequential stimulation of peripheral and central chemoreceptors triggered 25 cross-correlograms with offset features. The results support the hypothesis that multiple afferent systems dynamically tune inspiratory drive in part via coordinated t-E neurons. PMID:25343784

  4. Heated, Humidified High-Flow Nasal Cannula vs Nasal Continuous Positive Airway Pressure for Respiratory Distress Syndrome of Prematurity: A Randomized Clinical Noninferiority Trial.

    PubMed

    Lavizzari, Anna; Colnaghi, Mariarosa; Ciuffini, Francesca; Veneroni, Chiara; Musumeci, Stefano; Cortinovis, Ivan; Mosca, Fabio

    2016-08-08

    Heated, humidified high-flow nasal cannula (HHHFNC) has gained increasing popularity as respiratory support for newborn infants thanks to ease of use and improved patient comfort. However, its role as primary therapy for respiratory distress syndrome (RDS) of prematurity needs to be further elucidated by large, randomized clinical trials. To determine whether HHHFNC provides respiratory support noninferior to nasal continuous positive airway pressure (nCPAP) or bilevel nCPAP (BiPAP) as a primary approach to RDS in infants older than 28 weeks' gestational age (GA). An unblinded, monocentric, randomized clinical noninferiority trial at a tertiary neonatal intensive care unit. Inborn infants at 29 weeks 0 days to 36 weeks 6 days of GA were eligible if presenting with mild to moderate RDS requiring noninvasive respiratory support. Criteria for starting noninvasive respiratory support were a Silverman score of 5 or higher or a fraction of inspired oxygen higher than 0.3 for a target saturation of peripheral oxygen of 88% to 93%. Infants were ineligible if they had major congenital anomalies or severe RDS requiring early intubation. Infants were enrolled between January 5, 2012, and June 28, 2014. Randomization to either HHHFNC at 4 to 6 L/min or nCPAP/BiPAP at 4 to 6 cm H2O. Need for mechanical ventilation within 72 hours from the beginning of respiratory support. The absolute risk difference in the primary outcome and its 95% confidence interval were calculated to determine noninferiority (noninferiority margin, 10%). An intention-to-treat analysis was performed. A total of 316 infants were enrolled in the study: 158 in the HHHFNC group (mean [SD] GA, 33.1 [1.9] weeks; 52.5% female) and 158 in the nCPAP/BiPAP group (mean [SD] GA, 33.0 [2.1] weeks; 47.5% female). The use of HHHFNC was noninferior to nCPAP with regard to the primary outcome: failure occurred in 10.8% vs 9.5% of infants, respectively (95% CI of risk difference, -6.0% to 8.6% [within the noninferiority

  5. [Study on computed tomography features of nasal septum cellule and its clinical significance].

    PubMed

    Huang, Dingqiang; Li, Wanrong; Gao, Liming; Xu, Guanqiang; Ou, Xiaoyi; Tang, Guangcai

    2008-03-01

    To investigate the features of nasal septum cellule in computed tomographic (CT) images and its clinical significance. CT scans data of nasal septum in 173 patients were randomly obtained from January 2001 to June 2005. Prevalence and clinical features were summarized in the data of 19 patients with nasal septum cellule retrospectively. (1) Nineteen cases with nasal septum cellule were found in 173 patients. (2) All nasal septum cellule of 19 cases located in perpendicular plate of the ethmoid bone, in which 8 cases located in upper part of nasal septum and 11 located in middle. (3) There were totally seven patients with nasal diseases related to nasal septum cellule, in which 3 cases with inflammation, 2 cases with bone fracture, 1 case with cholesterol granuloma, 1 case with mucocele. Nasal septum cellule is an anatomic variation of nasal septum bone, and its features can provide further understanding of some diseases related to nasal septum cellule.

  6. CT analysis of nasal volume changes after surgically-assisted rapid maxillary expansion.

    PubMed

    Tausche, Eve; Deeb, Wayel; Hansen, Lars; Hietschold, Volker; Harzer, Winfried; Schneider, Matthias

    2009-07-01

    Aim of this study was to detect the changes in nasal volume due to bone-borne, surgically-assisted rapid palatal expansion (RPE) with the Dresden Distractor using computed tomography (CT). 17 patients (mean age 28.8) underwent axial CT scanning before and 6 months after RPE. The nasal bone width was examined in the coronal plane. Cross-sectional images of the nasal cavity were taken of the area surrounding the piriform aperture, choanae and in between. Bony nasal volume was computed by connecting the three cross-sectional areas. All but two patients showed a 4.8% increase in nasal volume (SD 4.6%). The highest value, 33.3% (SD 45.1%), was measured anteriorly at the level of the nasal floor. This correlated with the midpalatal suture's V-shaped opening. There was no significant correlation between an increase in nasal volume and transverse dental arch expansion. As most of the air we breathe passes the lower nasal floor, an improvement in nasal breathing is likely.

  7. Influence of Altered Auditory Feedback on Oral-Nasal Balance in Speech

    ERIC Educational Resources Information Center

    de Boer, Gillian; Bressmann, Tim

    2017-01-01

    Purpose: This study explored the role of auditory feedback in the regulation of oral-nasal balance in speech. Method: Twenty typical female speakers wore a Nasometer 6450 (KayPentax) headset and headphones while continuously repeating a sentence with oral and nasal sounds. Oral-nasal balance was quantified with nasalance scores. The signals from 2…

  8. Nasal biopsies of children exposed to air pollutants.

    PubMed

    Calderón-Garcidueñas, L; Rodriguez-Alcaraz, A; Valencia-Salazar, G; Mora-Tascareño, A; García, R; Osnaya, N; Villarreal-Calderón, A; Devlin, R B; Van Dyke, T

    2001-01-01

    Southwest Metropolitan Mexico City (SWMMC) atmosphere is a complex mixture of air pollutants, including ozone, particulate matter, and aldehydes. Children in SWMMC are exposed chronically and sequentially to numerous toxicants, and they exhibit significant nasal damage. The objective of this study was to assess p53 accumulation by immunohistochemistry in nasal biopsies of SWMMC children. We evaluated 111 biopsies from 107 children (83 exposed SWMMC children and 24 control children residents in a pollutant-compliant Caribbean island). Complete clinical histories and physical examinations, including an ear-nose-throat (ENT) exam were done. There was a significant statistical difference in the upper and lower respiratory symptomatology and ENT findings between control and exposed children (p < 0.001). Control children gave no respiratory symptomatology in the 3 months prior to the study; their biopsies exhibited normal ciliated respiratory epithelium and were p53-negative. SWMMC children complained of epistaxis, nasal obstruction. and crusting. Irregular areas of whitish-gray recessed mucosa over the inferior and middle turbinates were seen in 25% of SWMMC children, and their nasal biopsies displayed basal cell hyperplasia, decreased numbers of ciliated and goblet cells, neutrophilic epithelial infiltrates, squamous metaplasia. and mild dysplasia. Four of 21 SWMMC children with grossly abnormal mucosal changes exhibited strong transmural nuclear p53 staining in their nasal biopsies (p 0.005, odds ratio 26). In the context of lifetime exposures to toxic and potentially carcinogenic air pollutants, p53 nasal induction in children could potentially represent. a) a checkpoint response to toxic exposures, setting up a selective condition for p53 mutation, or b) a p53 mutation has already occurred as a result of such selection. Because the biological significance of p53 nuclear accumulation in the nasal biopsies of these children is not clear at this point, we strongly

  9. Using high-flow nasal cannulas for infants with bronchiolitis admitted to paediatric wards is safe and feasible.

    PubMed

    Heikkilä, Paula; Sokuri, Paula; Mecklin, Minna; Nuolivirta, Kirsi; Tapiainen, Terhi; Peltoniemi, Outi; Renko, Marjo; Korppi, Matti

    2018-05-26

    Using a high-flow nasal cannula (HFNC) for infant bronchiolitis is increasingly common, but insufficiently studied. In this retrospective study, we examined the outcomes of HFNC and compared infants who did and did not respond to this oxygen delivery method. This 2012-2015 study of six Finnish hospitals focused on 88 infants under 12 months who received HFNC: 53 on paediatric wards and 35 in paediatric intensive care units (PICUs). We reviewed patient files for underlying factors, clinical parameters and HFNC treatment. The treatment failed if the patient was transferred to another respiratory support. We found HFNC treatment was successful in 76 (86%) infants, including all 53 on the paediatric wards and 23/35 PICU patients. The responders' heart rates were significantly lower, and their oxygen saturation was significantly higher at 60 minutes after HFNC treatment started and then stayed relatively constant. Their respiratory rate was only significantly lower after 360 minutes. In non-responders, the respiratory rate initially decreased but was higher at 180 and 360 minutes after the start of HFNC. We found preliminary evidence that oxygen support needs and heart rate were useful early predictors of HFNC therapy success in infants hospitalised with bronchiolitis, but respiratory rate was not. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  10. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  11. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  12. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  13. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  14. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  15. Downregulation of peroxisome proliferator-activated receptors (PPARs) in nasal polyposis

    PubMed Central

    Cardell, Lars-Olaf; Hägge, Magnus; Uddman, Rolf; Adner, Mikael

    2005-01-01

    Background Peroxisome proliferator-activated receptor (PPAR) α, βδ and γ are nuclear receptors activated by fatty acid metabolites. An anti-inflammatory role for these receptors in airway inflammation has been suggested. Methods Nasal biopsies were obtained from 10 healthy volunteers and 10 patients with symptomatic allergic rhinitis. Nasal polyps were obtained from 22 patients, before and after 4 weeks of local steroid treatment (fluticasone). Real-time RT-PCR was used for mRNA quantification and immunohistochemistry for protein localization and quantification. Results mRNA expression of PPARα, PPARβδ, PPARγ was found in all specimens. No differences in the expression of PPARs were obtained in nasal biopsies from patients with allergic rhinitis and healthy volunteers. Nasal polyps exhibited lower levels of PPARα and PPARγ than normal nasal mucosa and these levels were, for PPARγ, further reduced following steroid treatment. PPARγ immunoreactivity was detected in the epithelium, but also found in smooth muscle of blood vessels, glandular acini and inflammatory cells. Quantitative evaluation of the epithelial immunostaining revealed no differences between nasal biopsies from patients with allergic rhinitis and healthy volunteers. In polyps, the PPARγ immunoreactivity was lower than in nasal mucosa and further decreased after steroid treatment. Conclusion The down-regulation of PPARγ, in nasal polyposis but not in turbinates during symptomatic seasonal rhinitis, suggests that PPARγ might be of importance in long standing inflammations. PMID:16271155

  16. Downregulation of peroxisome proliferator-activated receptors (PPARs) in nasal polyposis.

    PubMed

    Cardell, Lars-Olaf; Hägge, Magnus; Uddman, Rolf; Adner, Mikael

    2005-11-07

    Peroxisome proliferator-activated receptor (PPAR) alpha, betadelta and gamma are nuclear receptors activated by fatty acid metabolites. An anti-inflammatory role for these receptors in airway inflammation has been suggested. Nasal biopsies were obtained from 10 healthy volunteers and 10 patients with symptomatic allergic rhinitis. Nasal polyps were obtained from 22 patients, before and after 4 weeks of local steroid treatment (fluticasone). Real-time RT-PCR was used for mRNA quantification and immunohistochemistry for protein localization and quantification. mRNA expression of PPARalpha, PPARbetadelta, PPARgamma was found in all specimens. No differences in the expression of PPARs were obtained in nasal biopsies from patients with allergic rhinitis and healthy volunteers. Nasal polyps exhibited lower levels of PPARalpha and PPARgamma than normal nasal mucosa and these levels were, for PPARgamma, further reduced following steroid treatment. PPARgamma immunoreactivity was detected in the epithelium, but also found in smooth muscle of blood vessels, glandular acini and inflammatory cells. Quantitative evaluation of the epithelial immunostaining revealed no differences between nasal biopsies from patients with allergic rhinitis and healthy volunteers. In polyps, the PPARgamma immunoreactivity was lower than in nasal mucosa and further decreased after steroid treatment. The down-regulation of PPARgamma, in nasal polyposis but not in turbinates during symptomatic seasonal rhinitis, suggests that PPARgamma might be of importance in long standing inflammations.

  17. Trans-septal suturing following septoplasty: an alternative for nasal packing.

    PubMed

    Ghimire, A; Limbu, T R; Bhandari, R

    2012-09-01

    Septoplasty is one of the most common otorhinolaryngologic surgical procedure. It is customary to place a pack in the nose as a part of nasal surgery to stop bleeding, enhance apposition of mucosal flaps, and stabilize the operated septal cartilage and bones. But nasal packing is not an innocuous procedure. The most common problem encountered by the patients after septoplasty with nasal pack is the pain and discomfort in post operative period. The study has been performed to compare the complications and outcome of septoplasty with or without nasal packing. Forty four patients were randomly allocated into two groups, Group A (n = 21) and Group B (n = 23). In Group A trans-septal suture and in Group B intranasal pack was used following septoplasty. Both groups were compared for postoperative pain, postoperative complications and surgical outcome. Among 44 patients 31 patients were male and 13 patients were female. Most of the patients ie 79.5% were operated for nasal obstruction. Only one patient had postoperative nasal bleeding requiring nasal pack in Group A. Higher Postoperative pain score, longer hospital stay and more complications were observed in Group B patients. No difference was found in patients' satisfaction after the operation. Septoplasty can be safely performed without postoperative nasal packing and is preferred to avoid postoperative pain, discomfort and other complications.

  18. Effect of Subcutaneous Dupilumab on Nasal Polyp Burden in Patients With Chronic Sinusitis and Nasal Polyposis: A Randomized Clinical Trial.

    PubMed

    Bachert, Claus; Mannent, Leda; Naclerio, Robert M; Mullol, Joaquim; Ferguson, Berrylin J; Gevaert, Philippe; Hellings, Peter; Jiao, Lixia; Wang, Lin; Evans, Robert R; Pirozzi, Gianluca; Graham, Neil M; Swanson, Brian; Hamilton, Jennifer D; Radin, Allen; Gandhi, Namita A; Stahl, Neil; Yancopoulos, George D; Sutherland, E Rand

    2016-02-02

    Dupilumab has demonstrated efficacy in patients with asthma and atopic dermatitis, which are both type 2 helper T-cell-mediated diseases. To assess inhibition of interleukins 4 and 13 with dupilumab in patients with chronic sinusitis and nasal polyposis. A randomized, double-blind, placebo-controlled parallel-group study conducted at 13 sites in the United States and Europe between August 2013 and August 2014 in 60 adults with chronic sinusitis and nasal polyposis refractory to intranasal corticosteroids with 16 weeks of follow-up. Subcutaneous dupilumab (a 600 mg loading dose followed by 300 mg weekly; n = 30) or placebo (n = 30) plus mometasone furoate nasal spray for 16 weeks. Change in endoscopic nasal polyp score (range, 0-8; higher scores indicate worse status) at 16 weeks (primary end point). Secondary end points included Lund-Mackay computed tomography (CT) score (range, 0-24; higher scores indicate worse status), 22-item SinoNasal Outcome Test score (range, 0-110; higher scores indicating worse quality of life; minimal clinically important difference ≥8.90), sense of smell assessed using the University of Pennsylvania Smell Identification Test (UPSIT) score (range, 0-40; higher scores indicate better status), symptoms, and safety. Among the 60 patients who were randomized (mean [SD] age, 48.4 years [9.4 years]; 34 men [56.7%]; 35 with comorbid asthma), 51 completed the study. The least squares (LS) mean change in nasal polyp score was -0.3 (95% CI, -1.0 to 0.4) with placebo and -1.9 (95% CI, -2.5 to -1.2) with dupilumab (LS mean difference, -1.6 [95% CI, -2.4 to -0.7]; P < .001). The LS mean difference between the 2 groups for the Lund-Mackay CT total score was -8.8 (95% CI, -11.1 to -6.6; P < .001). Significant improvements with dupilumab were also observed for the 22-item SinoNasal Outcome Test (LS mean difference between groups, -18.1 [95% CI, -25.6 to -10.6]; P < .001) and sense of smell assessed by UPSIT (LS mean difference, 14

  19. Work of breathing during CPAP and heated humidified high-flow nasal cannula.

    PubMed

    Shetty, Sandeep; Hickey, Ann; Rafferty, Gerrard F; Peacock, Janet L; Greenough, Anne

    2016-09-01

    To determine whether continuous positive airway pressure (CPAP) compared with heated humidified, high-flow nasal cannula (HHFNC) in infants with evolving or established bronchopulmonary dysplasia (BPD) reduced the work of breathing (WOB) and thoracoabdominal asynchrony (TAA) and improved oxygen saturation (SaO2). Randomised crossover study. Tertiary neonatal unit. 20 infants (median gestational age of 27.6 weeks (range 24.6-31.9 weeks)) were studied at a median postnatal age of 30.9 weeks (range 28.1-39.1 weeks). Infants were studied on 2 consecutive days. On the first study day, they were randomised to either CPAP or HHFNC each for 2 h, the order being reversed on the second day. The WOB was assessed by measuring the pressure time product of the diaphragm (PTPdi). PTPdi, TAA and SaO2 were assessed during the final 5 min of each 2 h period and the results on the two study days were meaned. There were no significant differences in the results on CPAP versus HHFNC: mean PTPdi 226 (range 126-294) versus 224 cm H2O/s/min (95% CI for difference: -27 to 22; p=0.85) (range 170-318) (p=0.82), mean TAA 13.4° (range 4.51°-23.32°) versus 14.01° (range 4.25°-23.86°) (95% CI for difference: -3.9 to 2.8: p=0.73) (p=0.63) and mean SaO2 95% (range 93%-100%) versus 95% (94%-99%), (95% CI for difference -1.8 to 0.5; p=0.25) (p=0.45). In infants with evolving or established BPD, CPAP compared with HHFNC offered no significant advantage with regard to the WOB, degree of asynchrony or oxygen saturation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Inverted papillomas and benign nonneoplastic lesions of the nasal cavity

    PubMed Central

    Casiano, Roy R.

    2012-01-01

    Background: Benign lesions of the nasal cavity represent a diverse group of pathologies. Furthermore, each of these disorders may present differently in any given patient as pain and discomfort, epistaxis, headaches, vision changes, or nasal obstruction. Although these nasal masses are benign, many of them have a significant capacity for local tissue destruction and symptomatology secondary to this destruction. Advances in office-based endoscopic nasendoscopy have equipped the otolaryngologist with a safe, inexpensive, and rapid means of directly visualizing lesions within the nasal cavity and the initiation of appropriate treatment. Methods: The purpose of this study is to review the diagnosis, management, and controversies of many of the most common benign lesions of the nasal cavity encountered by the primary care physician or otolaryngologist. Results: This includes discussion of inverted papilloma (IP), juvenile angiofibroma, squamous papilloma, pyogenic granuloma, hereditary hemorrhagic telangiectasia, schwannoma, benign fibro-osseous lesions, and other benign lesions of the nasal cavity, with particular emphasis on IP and juvenile angiofibroma. Conclusion: A diverse array of benign lesions occur within the nasal cavity and paranasal cavities. Despite their inability to metastasize, many of these lesions have significant capability for local tissue destruction and recurrence. PMID:22487294

  1. May nasal hyperreactivity be a sequela of recurrent common cold?

    PubMed

    Cassano, M; Cassano, P; Ciprandi, G

    2011-01-01

    Respiratory viral infections may worsen bronchial hyperreactivity. However, there is no data on the possible role of recurrent infectious rhinitis in nose hyperreactivity. This study was therefore designed to investigate whether subjects suffering from recurrent common cold have nasal hyperreactivity, assessed by histamine nasal challenge. This study included a group of 40 patients (19 males, mean age 34.1 years) with history of at least five episodes of common cold in the previous year, but without documented allergy, and twenty healthy subjects (8 males, mean age 32.3 years) were enrolled as control group, all of whom were non-allergic. Nasal provocation test with histamine was performed in all subjects. Nasal provocation test with histamine induced a 200% increase in nasal resistance after provocation in 24 (60%) patients suffering from recurrent viral rhinitis. No normal subject had an increase >180% in nasal resistance. There was a significant difference between the patient group and the control group (p<0.05). In conclusion, this study shows that nasal hyperreactivity might be a sequela of recurrent common cold. Further studies should be conducted to confirm this preliminary finding.

  2. Is Surgical Navigation Useful During Closed Reduction of Nasal Bone Fractures?

    PubMed

    Kim, Seon Tae; Jung, Joo Hyun; Kang, Il Gyu

    2017-05-01

    To report the case of a 42-year-old woman with a nasal bone fracture that was easily treated using a surgical navigation system. In this clinical report, the authors suggest that intraoperative surgical navigation systems are useful diagnostically and for localizing sites of nasal bone fractures exactly. The patient underwent successful closed reduction of the nasal bone fracture. Surgical navigation is a useful tool for identifying nasal bone fracture locations and for guiding closed reduction. Surgical navigation is recommended when nasal bone fractures are complicated or not well reduced using the ordinary method.

  3. The morphological interaction between the nasal cavity and maxillary sinuses in living humans.

    PubMed

    Holton, Nathan; Yokley, Todd; Butaric, Lauren

    2013-03-01

    To understand how variation in nasal architecture accommodates the need for effective conditioning of respired air, it is necessary to assess the morphological interaction between the nasal cavity and other aspects of the nasofacial skeleton. Previous studies indicate that the maxillary sinuses may play a key role in accommodating climatically induced nasal variation such that a decrease in nasal cavity volume is associated with a concomitant increase in maxillary sinus volume. However, due to conflicting results in previous studies, the precise interaction of the nasal cavity and maxillary sinuses, in humans, is unclear. This is likely due to the prior emphasis on nasal cavity size, whereas arguably, nasal cavity shape is more important with regard to the interaction with the maxillary sinuses. Using computed tomography scans of living human subjects (N=40), the goal of this study is to assess the interaction between nasal cavity form and maxillary sinus volume in European- and African-derived individuals with differences in nasal cavity morphology. First, we assessed whether there is an inverse relationship between nasal cavity and maxillary sinus volumes. Next, we examined the relationship between maxillary sinus volume and nasal cavity shape using multivariate regression. Our results show that there is a positive relationship between nasal cavity and maxillary sinus volume, indicating that the maxillary sinuses do not accommodate variation in nasal cavity size. However, maxillary sinus volume is significantly correlated with variation in relative internal nasal breadth. Thus, the maxillary sinuses appear to be important for accommodating nasal cavity shape rather than size. Copyright © 2013 Wiley Periodicals, Inc.

  4. TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanaka, R; Sanada, S; Sakuta, K

    Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer.more » After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography

  5. A novel v- silicone vestibular stent: preventing vestibular stenosis and preserving nasal valves.

    PubMed

    Bassam, Wameedh Al; Bhargava, Deepa; Al-Abri, Rashid

    2012-01-01

    This report presents a novel style of placing nasal stents. Patients undergoing surgical procedures in the region of nasal vestibule and nasal valves are at risk of developing vestibular stenosis and lifelong problems with the external and internal nasal valves; sequels of the repair. The objective of the report is to demonstrate a simple and successful method of an inverted V- Stent placement to prevent potential complication of vestibular stenosis and nasal valve compromise later in life. Following a fall on a sharp edge of a metallic bed, a sixteen month old child with a deep lacerated nasal wound extending from the collumellar base toward the tip of the nose underwent surgical exploration and repair of the nasal vestibule and nasal cavity. A soft silicone stent fashioned as inverted V was placed bilaterally. The child made a remarkable recovery with no evidence of vestibular stenosis or nasal valve abnormalities. In patients with nasal trauma involving the nasal vestibule and internal and external nasal valves stent placement avoids sequels, adhesions, contractures, synechia vestibular stenosis and fibrosis involving these anatomical structures. The advantages of the described V- stents over the traditional readymade ridged nasal stents, tubing's and composite aural grafts are: a) technical simplicity of use, b) safety, c) less morbidity, d) more comfortable, and e) economical. To our knowledge, this is the first report of such a stent for prevention of vestibular stenosis and preserving nasal valves.

  6. A Novel V- Silicone Vestibular Stent: Preventing Vestibular Stenosis and Preserving Nasal Valves

    PubMed Central

    Bassam, Wameedh AL; Bhargava, Deepa; Al-Abri, Rashid

    2012-01-01

    This report presents a novel style of placing nasal stents. Patients undergoing surgical procedures in the region of nasal vestibule and nasal valves are at risk of developing vestibular stenosis and lifelong problems with the external and internal nasal valves; sequels of the repair. The objective of the report is to demonstrate a simple and successful method of an inverted V- Stent placement to prevent potential complication of vestibular stenosis and nasal valve compromise later in life. Following a fall on a sharp edge of a metallic bed, a sixteen month old child with a deep lacerated nasal wound extending from the collumellar base toward the tip of the nose underwent surgical exploration and repair of the nasal vestibule and nasal cavity. A soft silicone stent fashioned as inverted V was placed bilaterally. The child made a remarkable recovery with no evidence of vestibular stenosis or nasal valve abnormalities. In patients with nasal trauma involving the nasal vestibule and internal and external nasal valves stent placement avoids sequels, adhesions, contractures, synechia vestibular stenosis and fibrosis involving these anatomical structures. The advantages of the described V- stents over the traditional readymade ridged nasal stents, tubing’s and composite aural grafts are: a) technical simplicity of use, b) safety, c) less morbidity, d) more comfortable, and e) economical. To our knowledge, this is the first report of such a stent for prevention of vestibular stenosis and preserving nasal valves. PMID:22359729

  7. Inter- and intra-rater reliability of nasal auscultation in daycare children.

    PubMed

    Santos, Rita; Silva Alexandrino, Ana; Tomé, David; Melo, Cristina; Mesquita Montes, António; Costa, Daniel; Pinto Ferreira, João

    2018-02-01

    The aim of this study was to assess nasal auscultation's intra- and inter-rater reliability and to analyze ear and respiratory clinical condition according to nasal auscultation. Cross-sectional study performed in 125 children aged up to 3 years old attending daycare centers. Nasal auscultation, tympanometry and Paediatric Respiratory Severity Score (PRSS) were applied to all children. Nasal sounds were classified by an expert panel in order to determine nasal auscultation's intra and inter- rater reliability. The classification of nasal sounds was assessed against tympanometric and PRSS values. Nasal auscultation revealed substantial inter-rater (K=0.75) and intra-rater (K=0.69; K=0.61 and K=0.72) reliability. Children with a "non-obstructed" classification revealed a lower peak pressure (t=-3.599, P<0.001 in left ear; t=-2.258, P=0.026 in right ear) and a higher compliance (t=-2,728, P=0.007 in left ear; t=-3.830. P<0.001 in right ear) in both ears. There was an association between the classification of sounds and tympanogram types in both ears (X=11.437, P=0.003 in left ear; X=13.535, P=0.001 in right ear). Children with a "non-obstructed" classification had a healthier respiratory condition. Nasal auscultation revealed substantial intra- and inter-rater reliability. Nasal auscultation exhibited important differences according to ear and respiratory clinical conditions. Nasal auscultation in pediatrics seems to be an original topic as well as a simple method that can be used to identify early signs of nasopharyngeal obstruction.

  8. The influence of listener experience and academic training on ratings of nasality.

    PubMed

    Lewis, Kerry E; Watterson, Thomas L; Houghton, Sarah M

    2003-01-01

    This study assessed listener agreement levels for nasality ratings, and the strength of relationship between nasality ratings and nasalance scores on one hand, and listener clinical experience and formal academic training in cleft palate speech on the other. The listeners were 12 adults who represented four levels of clinical experience and academic training in cleft palate speech. Three listeners were teachers with no clinical experience and no academic training (TR), three were graduate students in speech-language pathology (GS) with academic training but no clinical experience, three were craniofacial surgeons (MD) with extensive experience listening to cleft palate speech but with no academic training in speech disorders, and three were certified speech-language pathologists (SLP) with both extensive academic training and clinical experience. The speech samples were audio recordings from 20 persons representing a range of nasality from normal to severely hypernasal. Nasalance scores were obtained simultaneously with the audio recordings. Results revealed that agreement levels for nasality ratings were highest for the SLPs, followed by the MDs. Thus, the more experienced groups tended to be more reliable. Mean nasality ratings obtained for each of the rater groups revealed an inverse relationship with experience. That is, the two groups with clinical experience (SLP and MD) tended to rate nasality lower than the two groups without experience (GS and TR). Correlation coefficients between nasalance scores and nasality judgments were low to moderate for all groups and did not follow a pattern. EDUCATIONAL OUTCOMES: As a result of this activity, the reader will be able to (1) describe the influence of listener experience and academic training in cleft palate speech on perceptual ratings of nasality. (2) describe the influence of experience and training on the nasality/nasalance relationship and, (3) compare the present findings to previous findings reported in the

  9. Extranasopharyngeal angiofibroma of the posterior nasal septum: a rare clinical entity.

    PubMed

    Atmaca, Sinan; Bayraktar, Cem; Yıldız, Levent

    2013-01-01

    Angiofibroma of extranasopharyngeal origin is very rare. Although it is usually originated from any mucosal structure in the head and neck region, maxilla is the most common involvement site. The nasal septum is an exceptional anatomic site of an angiofibroma. Surgery is the best treatment modality and recurrence is very rare. Nasal septal angiofibromas must be considered in the differential diagnosis of nasal vascular masses arising from the nasal septum. In this article, we report a 37-year-old male case with nasal septal angiofibroma who underwent surgical resection of the tumor. This is the 16th case in the literature.

  10. Anatomy and Surgical Approaches to the Rabbit Nasal Septum.

    PubMed

    Badran, Karam W; Chang, John C; Kuan, Edward C; Wong, Brian J F

    2017-09-01

    The rabbit is the primary animal model used to investigate aspects of nasal surgery. Although several studies have used this model, none has provided a comprehensive analysis of the surgical anatomy and techniques used to gain access to the rabbit nasal fossae and septum. To describe and optimize the surgical anatomy and approach to the rabbit nasal vault and septal cartilage. In an ex vivo animal study conducted at an academic medical center, preliminary cadaveric dissections were performed on rabbit head specimens to establish familiarity with relevant anatomy and rehearse various approaches. Live Pasteurella-free New Zealand white rabbits (3.5-4.0 kg) were used to further develop this surgical technique developed here. Access of the nasal vault was gained through a midline nasal dorsum incision and creation of an osteoplastic flap with a drill. Submucosal resection was performed with preservation of the mucoperichondrium. All rabbits were monitored daily for 4 weeks in the postoperative period for signs of infection, pain, and complications. The study was conducted from June 1, 2014, to December 1, 2014. Surgical anatomy and techniques used to gain access to the rabbit nasal vault and harvest septal cartilage. Four Pasteurella-free New Zealand white rabbits (Western Organ Rabbit Co), ranging in age from 9 to 12 months and weighing between 3.5 and 4.0 kg, were used in this study. Initial dissections demonstrated the feasibility of harvesting septal cartilage while preserving the mucoperichondrial envelope. Access to the nasal vault through this 3-osteotomy approach allowed for maximal exposure to the nasal cavity bilaterally while maintaining the integrity of the mucoperichondrium following septal cartilage harvest. The maximum amount of bulk, en bloc, cartilage harvested was 1.0 × 2.5 cm. Following surgical dissection, all animals maintained adequate airway patency and support to midface structures. Furthermore, all specimens preserved the integrity of the

  11. Accuracy of Administrative Codes for Distinguishing Positive Pressure Ventilation from High-Flow Nasal Cannula.

    PubMed

    Good, Ryan J; Leroue, Matthew K; Czaja, Angela S

    2018-06-07

    Noninvasive positive pressure ventilation (NIPPV) is increasingly used in critically ill pediatric patients, despite limited data on safety and efficacy. Administrative data may be a good resource for observational studies. Therefore, we sought to assess the performance of the International Classification of Diseases, Ninth Revision procedure code for NIPPV. Patients admitted to the PICU requiring NIPPV or heated high-flow nasal cannula (HHFNC) over the 11-month study period were identified from the Virtual PICU System database. The gold standard was manual review of the electronic health record to verify the use of NIPPV or HHFNC among the cohort. The presence or absence of a NIPPV procedure code was determined by using administrative data. Test characteristics with 95% confidence intervals (CIs) were generated, comparing administrative data with the gold standard. Among the cohort ( n = 562), the majority were younger than 5 years, and the most common primary diagnosis was bronchiolitis. Most (82%) required NIPPV, whereas 18% required only HHFNC. The NIPPV code had a sensitivity of 91.1% (95% CI: 88.2%-93.6%) and a specificity of 57.6% (95% CI: 47.2%-67.5%), with a positive likelihood ratio of 2.15 (95% CI: 1.70-2.71) and negative likelihood ratio of 0.15 (95% CI: 0.11-0.22). Among our critically ill pediatric cohort, NIPPV procedure codes had high sensitivity but only moderate specificity. On the basis of our study results, there is a risk of misclassification, specifically failure to identify children who require NIPPV, when using administrative data to study the use of NIPPV in this population. Copyright © 2018 by the American Academy of Pediatrics.

  12. [Clinical symptoms and immunology inspection characteristics of nasal cavity local allergy].

    PubMed

    Yin, Z X; Zhu, Y; Zhai, X; Zhang, J L; Liu, G

    2017-08-05

    Objective: To investigate the clinical symptoms and immunology inspection characteristics of nasal cavity local allergy. Method: Selected 60 patients as observation group, who had only nasal local allergy symptoms, allergen skin prick test and serum allergen specific IgE (SIgE) test were negative, 40 allergic rhinitis (AR) patients and 40 healthy volunteers as control groups. To detect Symptom scores and VAS scores, and eosinophilia counts in venous blood, allergen skin prick test (SPT), serum allergen SIgE test, nasal secretions allergen SIgE test, nasal mucous membrane excitation test in both observation group and AR group, eosinophilia counts in nasal secretion, taked the data for statistical analysis. Result: There was no difference ( P > 0.05) in the symptom scores and VAS scores of observation group and the AR group. The eosinophilia counts in venous blood in the AR group were higher than in the observation group ( P < 0.05). The eosinophilia counts in venous blood in the observation group were higher than in the healthy volunteers group ( P < 0.05). The positive rate of nasal secretions dust mites and pollen allergen was 90% (54/60) in observation group. There was no significant difference ( P > 0.05) in the eosinophilia percentages in nasal secretion in the observation group and the AR group. There was significant difference ( P < 0.05) in the eosinophilia percentages in nasal secretion in the observation group and the healthy volunteers group. There were 6 patients in observation group whose nasal secretions allergen SIgE test and nasal mucous membrane excitation test were both negative, could be diagnosised as non-allergic rhinitis (NAR). According to eosinophilia counts in venous blood and nasal secretions, 4 patients were diagnosised as vasomotor rhinitis and 2 patients were diagnosised as NAR with eosinophilia syndrome. There were 54 patients in observation group whose nasal secretions allergen SIgE test and (or) nasal mucous membrane excitation test

  13. Nasal aerodynamics protects brain and lung from inhaled dust in subterranean diggers, Ellobius talpinus.

    PubMed

    Moshkin, M P; Petrovski, D V; Akulov, A E; Romashchenko, A V; Gerlinskaya, L A; Ganimedov, V L; Muchnaya, M I; Sadovsky, A S; Koptyug, I V; Savelov, A A; Troitsky, S Yu; Moshkn, Y M; Bukhtiyarov, V I; Kolchanov, N A; Sagdeev, R Z; Fomin, V M

    2014-10-07

    Inhalation of air-dispersed sub-micrometre and nano-sized particles presents a risk factor for animal and human health. Here, we show that nasal aerodynamics plays a pivotal role in the protection of the subterranean mole vole Ellobius talpinus from an increased exposure to nano-aerosols. Quantitative simulation of particle flow has shown that their deposition on the total surface of the nasal cavity is higher in the mole vole than in a terrestrial rodent Mus musculus (mouse), but lower on the olfactory epithelium. In agreement with simulation results, we found a reduced accumulation of manganese in olfactory bulbs of mole voles in comparison with mice after the inhalation of nano-sized MnCl2 aerosols. We ruled out the possibility that this reduction is owing to a lower transportation from epithelium to brain in the mole vole as intranasal instillations of MnCl2 solution and hydrated nanoparticles of manganese oxide MnO · (H2O)x revealed similar uptake rates for both species. Together, we conclude that nasal geometry contributes to the protection of brain and lung from accumulation of air-dispersed particles in mole voles. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  14. Nasal erosion as an uncommon sign of child abuse.

    PubMed

    Culotta, Paige A; Isaac, Reena; Sarpong, Kwabena; Chandy, Binoy; Cruz, Andrea; Donaruma-Kwoh, Marcella

    2018-05-01

    While various forms of facial trauma, bruising, burns, and fractures are frequently seen in cases of child abuse, purposeful nasal erosion has rarely been identified as a form of abusive injury. Progressive destruction of nasal tissue in children provokes a wide differential diagnosis crossing multiple subspecialties: infectious, primary immunodeficiencies, inflammatory conditions, malignancy, and genetic disorders. Progressive nasal erosion also can be a manifestation of child abuse. The proposed mechanism is repetitive mechanical denudation of the soft tissue and cartilage resulting in chronic inflammation, bleeding, and ultimately destruction of the insulted tissue. We report 6 cases of child abuse manifesting as overt nasal destruction. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Nasal cavity ossifying fibrosarcoma: an unusual fibro-osseous neoplasm.

    PubMed

    Alameda, Yadiel A; Perez-Mitchell, Carlos; Busquets, José M

    2010-11-01

    We describe the case of a 65-year-old woman who presented with left nasal obstruction. Clinical and radiographic examinations revealed the presence of a soft-tissue mass that had obliterated the left nasal cavity. The mass was completely excised via an endoscopic approach. Histopathologic examination identified the tumor as an ossifying fibrosarcoma. The patient recovered uneventfully and remained free of disease at the 2-year postoperative follow-up. To the best of our knowledge, no case of an ossifying fibrosarcoma of the nasal cavity has been previously reported in the English-language literature. We discuss the features of this case and the clinical presentation, diagnosis, and management of fibrosarcomas of the nasal cavity and paranasal sinuses.

  16. Tolerability and effects on quality of life of liposomal nasal spray treatment compared to nasal ointment containing dexpanthenol or isotonic NaCl spray in patients with rhinitis sicca.

    PubMed

    Hahn, C; Böhm, M; Allekotte, S; Mösges, R

    2013-09-01

    This study aimed to investigate symptom reduction via the liposomal nasal spray LipoNasal (LN) in patients with rhinitis sicca. Tolerability and the impact on quality of life were also examined. The same parameters were established in parallel for treatment approaches with Bepanthen (BP) nasal ointment containing dexpanthenol and the Rhinomer (RH) nasal spray containing NaCl. This prospective, controlled, open-label observation study was a multicenter trial. 92 patients with rhinitis sicca were allocated to three arms according to their symptoms: LN: n = 33; BP: n = 32 and RH: n = 27. The study comprised three visits at an interval of 14 days. Efficacy was examined by the Rhinitis Sicca Symptom Score (RSSS) documented daily and at the visits based on an endoscopic evaluation. The nasal spray sensory scale was used to investigate the tolerability. Quality of life (QoL) was measured by means of the Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ) and the "Short Form 12" of the "Impact on Health-Related Quality of Life (HRQL)" questionnaire on general quality of life. Nasal symptoms improved significantly (p = 0.001) under all three treatment approaches, reflected by the reduction in the RSSS and the Endoscopy Sum Score. A comparison of the three groups showed that no therapy was significantly superior to any of the others (p = 0.410). The tolerability of all treatments was good. Concerning the nasal moisturization, LipoNasal was evaluated better than Bepanthen and Rhinomer. Quality of life improved in all groups, but not significantly. The results show good efficacy and tolerability of the liposomal nasal spray compared to generally recognized treatments of rhinitis sicca with dexpanthenol nasal ointment and NaCl nasal spray. LipoNasal therefore constitutes a good treatment for patients suffering from dry nose.

  17. Nasal conchae function as aerodynamic baffles: Experimental computational fluid dynamic analysis in a turkey nose (Aves: Galliformes).

    PubMed

    Bourke, Jason M; Witmer, Lawrence M

    2016-12-01

    We tested the aerodynamic function of nasal conchae in birds using CT data from an adult male wild turkey (Meleagris gallopavo) to construct 3D models of its nasal passage. A series of digital "turbinectomies" were performed on these models and computational fluid dynamic analyses were performed to simulate resting inspiration. Models with turbinates removed were compared to the original, unmodified control airway. Results revealed that the four conchae found in turkeys, along with the crista nasalis, alter the flow of inspired air in ways that can be considered baffle-like. However, these baffle-like functions were remarkably limited in their areal extent, indicating that avian conchae are more functionally independent than originally hypothesized. Our analysis revealed that the conchae of birds are efficient baffles that-along with potential heat and moisture transfer-serve to efficiently move air to specific regions of the nasal passage. This alternate function of conchae has implications for their evolution in birds and other amniotes. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Effects of Heated Humidification and Topical Steroids on Compliance, Nasal Symptoms, and Quality of Life in Patients with Obstructive Sleep Apnea Syndrome Using Nasal Continuous Positive Airway Pressure

    PubMed Central

    Ryan, Silke; Doherty, Liam S.; Nolan, Geraldine M.; McNicholas, Walter T.

    2009-01-01

    Background: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. Methods: 125 patients with the established diagnosis of OSAS (apnea/hypopnea index ≥ 10/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. Results: There was no difference in compliance between groups after 4 weeks (dry: 5.21 ± 1.66 h/night, fluticasone: 5.66 ± 1.68, humidifier: 5.21 ± 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. Conclusion: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered. Citation: Ryan S; Doherty LS; Nolan GM; McNicholas WT. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal

  19. Characterization of the nasal and oral microbiota of detection dogs.

    PubMed

    Isaiah, Anitha; Hoffmann, Aline Rodrigues; Kelley, Russ; Mundell, Paul; Steiner, Jörg M; Suchodolski, Jan S

    2017-01-01

    Little is known about physiological factors that affect the sense of olfaction in dogs. The objectives of this study were to describe the canine nasal and oral microbiota in detection dogs. We sought to determine the bacterial composition of the nasal and oral microbiota of a diverse population of detection canines. Nasal and oral swabs were collected from healthy dogs (n = 81) from four locations-Alabama, Georgia, California, and Texas. Nasal and oral swabs were also collected from a second cohort of detection canines belonging to three different detection job categories: explosive detection dogs (SP-E; n = 22), patrol and narcotics detection dogs (P-NDD; n = 15), and vapor wake dogs (VWD-E; n = 9). To understand if the nasal and oral microbiota of detection canines were variable, sample collection was repeated after 7 weeks in a subset of dogs. DNA was extracted from the swabs and used for 454-pyrosequencing of the16S rRNA genes. Nasal samples had a significantly lower diversity than oral samples (P<0.01). Actinobacteria and Proteobacteria were higher in nasal samples, while Bacteroidetes, Firmicutes, Fusobacteria, and Tenericutes were higher in oral samples. Bacterial diversity was not significantly different based on the detection job. No significant difference in beta diversity was observed in the nasal samples based on the detection job. In oral samples, however, ANOSIM suggested a significant difference in bacterial communities based on job category albeit with a small effect size (R = 0.1079, P = 0.02). Analysis of the composition of bacterial communities using LEfSe showed that within the nasal samples, Cardiobacterium and Riemerella were higher in VWD-E dogs, and Sphingobacterium was higher in the P-NDD group. In the oral samples Enterococcus and Capnocytophaga were higher in the P-NDD group. Gemella and Aggregatibacter were higher in S-PE, and Pigmentiphaga, Chryseobacterium, Parabacteroides amongst others were higher within the VWD-E group. Our initial

  20. Characterization of the nasal and oral microbiota of detection dogs

    PubMed Central

    Hoffmann, Aline Rodrigues; Kelley, Russ; Mundell, Paul; Steiner, Jörg M.

    2017-01-01

    Little is known about physiological factors that affect the sense of olfaction in dogs. The objectives of this study were to describe the canine nasal and oral microbiota in detection dogs. We sought to determine the bacterial composition of the nasal and oral microbiota of a diverse population of detection canines. Nasal and oral swabs were collected from healthy dogs (n = 81) from four locations—Alabama, Georgia, California, and Texas. Nasal and oral swabs were also collected from a second cohort of detection canines belonging to three different detection job categories: explosive detection dogs (SP-E; n = 22), patrol and narcotics detection dogs (P-NDD; n = 15), and vapor wake dogs (VWD-E; n = 9). To understand if the nasal and oral microbiota of detection canines were variable, sample collection was repeated after 7 weeks in a subset of dogs. DNA was extracted from the swabs and used for 454-pyrosequencing of the16S rRNA genes. Nasal samples had a significantly lower diversity than oral samples (P<0.01). Actinobacteria and Proteobacteria were higher in nasal samples, while Bacteroidetes, Firmicutes, Fusobacteria, and Tenericutes were higher in oral samples. Bacterial diversity was not significantly different based on the detection job. No significant difference in beta diversity was observed in the nasal samples based on the detection job. In oral samples, however, ANOSIM suggested a significant difference in bacterial communities based on job category albeit with a small effect size (R = 0.1079, P = 0.02). Analysis of the composition of bacterial communities using LEfSe showed that within the nasal samples, Cardiobacterium and Riemerella were higher in VWD-E dogs, and Sphingobacterium was higher in the P-NDD group. In the oral samples Enterococcus and Capnocytophaga were higher in the P-NDD group. Gemella and Aggregatibacter were higher in S-PE, and Pigmentiphaga, Chryseobacterium, Parabacteroides amongst others were higher within the VWD-E group. Our