Sample records for nasal optic disc

  1. Retinal displacement toward optic disc after internal limiting membrane peeling for idiopathic macular hole.

    PubMed

    Ishida, Masahiro; Ichikawa, Yoshikazu; Higashida, Rieko; Tsutsumi, Yorihisa; Ishikawa, Atsushi; Imamura, Yutaka

    2014-05-01

    To examine the retinal displacement following successful macular hole (MH) surgery with internal limiting membrane (ILM) peeling and gas tamponade, and to determine the correlation between the extent of displacement and the basal MH size. Retrospective, interventional, observational case series. The medical records of consecutive patients with an idiopathic MH that had undergone vitrectomy with ILM peeling and gas tamponade were studied. The distances between the optic disc and the intersection of 2 retinal vessels located nasal or temporal to the fovea were measured manually preoperatively (A), and 2 weeks and 1, 3, 6, and 12 months postoperatively (B), on the fundus autofluorescence or near-infrared images. The basal and minimum diameters of the MHs were measured in the spectral-domain optical coherence tomographic images. The correlations between the ratio of the retinal displacement (A - B/A) and basal diameters of the MHs were determined. Twenty-one eyes of 21 patients (9 men, mean age: 64.6 ± 8.4 years) were studied. Ten eyes (47.6%) had stage 2 MH, 9 eyes (42.9%) had stage 3 MH, and 2 eyes (9.5%) had stage 4 MH. The temporal retinal vessels were displaced 260.8 ± 145.8 μm toward the optic disc at 2 weeks postoperatively, which was significantly greater than the 91.1 ± 89.7 μm of the nasal retinal vessels (paired t test, P < .001). The ratio of retinal displacement in the temporal field at 2 weeks was significantly correlated with the basal diameter of the MH (Spearman's rank correlation coeffieient = -0.476, P = .033. The greater displacement of the temporal retina than the nasal retina toward the optic disc postoperatively suggests that the temporal retina is more flexible and can be retracted toward the optic disc during the MH closure. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Optic Disc Drusen in Children

    PubMed Central

    Chang, Melinda Y.; Pineles, Stacy L.

    2016-01-01

    Optic disc drusen occur in 0.4% of children and consist of acellular intracellular and extracellular deposits that often become calcified over time. They are typically buried early in life and generally become superficial, and therefore visible, later in childhood, at the average age of 12 years. Their main clinical significance lies in the ability of optic disc drusen, particularly when buried, to simulate true optic disc edema. Misdiagnosing drusen as true disc edema may lead to an invasive and unnecessary workup for elevated intracranial pressure. Ancillary testing, including ultrasonography, fluorescein angiography, fundus autofluorescence, and optical coherence tomography, may aid in the correct diagnosis of optic disc drusen. Complications of optic disc drusen in children include visual field defects, hemorrhages, choroidal neovascular membrane, non-arteritic anterior ischemic optic neuropathy, and retinal vascular occlusions. Treatment options for these complications include ocular hypotensive agents for visual field defects and intravitreal anti-vascular endothelial growth factor (anti-VEGF) agents for choroidal neovascular membranes. In most cases, however, children with optic disc drusen can be managed by observation with serial examinations and visual field testing, once true optic disc edema has been excluded. PMID:27033945

  3. Bilateral Optic Disc Drusen Mimicking Papilledema

    PubMed Central

    Cingü, Abdullah Kürşat; Ari, Şeyhmus; Çinar, Yasin; Çaça, İhsan

    2012-01-01

    Background Optic disc drusen, which are calcified deposits that form anterior to the lamina cribrosa in the optic nerve, may mimic papilledema. Case Report We report herein three cases referred to us with suspicion of disc swelling and papilledema. Following ophthalmologic evaluation with B-scan ultrasound, red-free fundus photography, and computed tomography, the diagnosis of papilledema was excluded in all cases and optic disc drusen was diagnosed. Conclusions Clinical suspicion of optic disc drusen in cases presenting with swelling of the optic nerve head is important in order to avoid unnecessary interventions and anxiety. The reported cases highlight the commonly encountered clinical presentations and the practical aspects of diagnosis and management of optic disc drusen. PMID:22787500

  4. Bilateral optic disc drusen mimicking papilledema.

    PubMed

    Sahin, Alparslan; Cingü, Abdullah Kürşat; Ari, Seyhmus; Cinar, Yasin; Caça, Ihsan

    2012-06-01

    Optic disc drusen, which are calcified deposits that form anterior to the lamina cribrosa in the optic nerve, may mimic papilledema. We report herein three cases referred to us with suspicion of disc swelling and papilledema. Following ophthalmologic evaluation with B-scan ultrasound, red-free fundus photography, and computed tomography, the diagnosis of papilledema was excluded in all cases and optic disc drusen was diagnosed. Clinical suspicion of optic disc drusen in cases presenting with swelling of the optic nerve head is important in order to avoid unnecessary interventions and anxiety. The reported cases highlight the commonly encountered clinical presentations and the practical aspects of diagnosis and management of optic disc drusen.

  5. Displacement of foveal area toward optic disc after macular hole surgery with internal limiting membrane peeling.

    PubMed

    Kawano, K; Ito, Y; Kondo, M; Ishikawa, K; Kachi, S; Ueno, S; Iguchi, Y; Terasaki, H

    2013-07-01

    To determine whether there is a displacement of the fovea toward the optic disc after successful macular hole (MH) surgery with internal limiting membrane (ILM) peeling. The medical records of 54 eyes of 53 patients that had undergone pars plana vitrectomy with ILM peeling and gas or air tamponade for an idiopathic MH were evaluated. Spectral-domain optical coherence tomography (OCT) had been performed before and >6 months after the surgery. The preoperative distances between the center of the MH and the optic disc (MH-OD), center of the MH and the bifurcation or crossing of retinal vessels (MH-RV) were measured in the OCT images. In addition, the postoperative distance between the center of the fovea and optic disc (F-OD) and the center of the fovea and the same bifurcation or crossing of retinal vessels (F-RV) were measured in the OCT images. The F-OD was 2.67±0.33 disc diameters (DD), which was significantly shorter than that of the MH-OD of 2.77±0.33 DD (P<0.001). The F-RV was also significantly shorter than the MH-RV on the inner nasal area (from 0.85±0.16DD to 0.79±0.15DD; P<0.001), the inner temporal area (from 0.82±0.15DD to 0.77±0.14DD; P<0.001), and outer nasal area (from 1.70±0.31DD to 1.65±0.32DD; P<0.001), but it was significantly longer than the MH-RV in the outer temporal area (from 1.65±0.29DD to 1.68±0.29DD; P<0.001). Our results showed that successful closure of a MH by vitrectomy with ILM peeling and gas tamponade leads to a displacement of the center of the macula toward the optic disc.

  6. Quantitating Human Optic Disc Topography

    NASA Astrophysics Data System (ADS)

    Graebel, William P.; Cohan, Bruce E.; Pearch, Andrew C.

    1980-07-01

    A method is presented for quantitatively expressing the topography of the human optic disc, applicable in a clinical setting to the diagnosis and management of glaucoma. Pho-tographs of the disc illuminated by a pattern of fine, high contrast parallel lines are digitized. From the measured deviation of the lines as they traverse the disc surface, disc topography is calculated, using the principles of optical sectioning. The quantitators applied to express this topography have the the following advantages : sensitivity to disc shape; objectivity; going beyond the limits of cup-disc ratio estimates and volume calculations; perfect generality in a mathematical sense; an inherent scheme for determining a non-subjective reference frame to compare different discs or the same disc over time.

  7. Bilateral Neuroretinitis in Cat Scratch Disease with Exudative, Obliterative Vasculitis in the Optic Disc.

    PubMed

    Tagawa, Yoshiaki; Suzuki, Yasuo; Sakaguchi, Takatoshi; Endoh, Hiroki; Yokoi, Masahiko; Kase, Manabu

    2014-01-01

    A 29-year-old fisherman exhibited optic disc oedema and peripapillary retinal detachment in the right eye, whereas in the left eye, optic atrophy and intraretinal exudates were already observed on first examination. About 6 months earlier, he noticed blurred vision of the left eye but took no medication. Visual acuity was 0.4 OD and 0.01 OS. Perimetry showed a large lower-half field defect with sparing 10° central field in the right eye and a large central scotoma in the left eye. Fluorescein angiography showed existence of arteriole or capillary nonperfusion and hyperpermeability of surrounding capillaries. Since serological examinations showed positive Bartonella immunoglobulin G (IgG) and other causes of neuroretinitis (NR) were excluded, NR in the present case was caused by cat scratch disease (CSD). Optic atrophy appeared 2 weeks after onset. Optical coherence tomography 13 weeks after onset revealed severe loss of retinal nerve fibre layer (RNFL) superior and nasal to the optic disc in both eyes and temporal in the left eye. Visual acuity of the right eye improved to 1.2 by the treatment, whereas visual field defects were persistent. CSD-NR in the present case developed abrupt appearance of optic atrophy with severe RNFL loss in the right eye, which was elicited by exudative, obliterative vasculitis in the superficial layer of the optic disc.

  8. Optic disc dysplasia in poland syndrome.

    PubMed

    Maxfield, Steven D; Strominger, Mitchell B

    2014-06-01

    To report optic disc dysplasia in a case of Poland syndrome. Non-interventional case report. A 2-year-old boy with Poland syndrome was referred for ophthalmic evaluation after abnormal optic discs were found on exam. Physical exam at birth revealed right-sided aplasia of the pectoralis major muscle, symbrachydactyly, hypoplastic scapula, and an abnormal third rib. On dilated examination the optic nerve heads were dysplastic. The findings included multiple cilioretinal vessels, situs inversus, inferotemporal excavation, and surrounding pigmentary disturbances. Only one case of optic disc anomaly has been reported in Poland syndrome and was described as morning glory syndrome. The optic discs in our patient do not fit well with other optic disc excavation syndromes but are most reminiscent of those in papillorenal syndrome. As both Poland syndrome and papillorenal syndrome share vascular dysfunction as a possible etiology, this case adds to the literature of vascular dysgenesis in Poland syndrome.

  9. Comparison of Optic Disc Margin Identified by Color Disc Photography and High-Speed Ultrahigh-Resolution Optical Coherence Tomography

    PubMed Central

    Manassakorn, Anita; Ishikawa, Hiroshi; Kim, Jong S.; Wollstein, Gadi; Bilonick, Richard A.; Kagemann, Larry; Gabriele, Michelle L.; Sung, Kyung Rim; Mumcuoglu, Tarkan; Duker, Jay S.; Fujimoto, James G.; Schuman, Joel S.

    2009-01-01

    Objective To determine the correspondence between optic disc margins evaluated using disc photography (DP) and optical coherence tomography (OCT). Methods From May 1, 2005, through November 10, 2005, 17 healthy volunteers (17 eyes) had raster scans (180 frames, 501 samplings per frame) centered on the optic disc taken with stereo-optic DP and high-speed ultrahigh-resolution OCT (hsUHR-OCT). Two image outputs were derived from the hsUHR-OCT data set: an en face hsUHR-OCT fundus image and a set of 180 frames of cross-sectional images. Three ophthalmologists independently and in a masked, randomized fashion marked the disc margin on the DP, hsUHR-OCT fundus, and cross-sectional images using custom software. Disc size (area and horizontal and vertical diameters) and location of the geometric disc center were compared among the 3 types of images. Results The hsUHR-OCT fundus image definition showed a significantly smaller disc size than the DP definition (P<.001, mixed-effects analysis). The hsUHR-OCT cross-sectional image definition showed a significantly larger disc size than the DP definition (P<.001). The geometric disc center location was similar among the 3 types of images except for the y-coordinate, which was significantly smaller in the hsUHR-OCT fundus images than in the DP images. Conclusion The optic disc margin as defined by hsUHR-OCT was significantly different than the margin defined by DP. PMID:18195219

  10. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma

    PubMed Central

    Jia, Yali; Wei, Eric; Wang, Xiaogang; Zhang, Xinbo; Morrison, John C.; Parikh, Mansi; Lombardi, Lori H.; Gattey, Devin M.; Armour, Rebecca L.; Edmunds, Beth; Kraus, Martin F.; Fujimoto, James G.; Huang, David

    2014-01-01

    Purpose To compare optic disc perfusion between normal and glaucoma subjects using optical coherence tomography (OCT) angiography and detect optic disc perfusion changes in glaucoma. Design Observational, cross-sectional study. Participants Twenty-four normal subjects and 11 glaucoma patients were included. Methods One eye of each subject was scanned by a high-speed 1050 nm wavelength swept-source OCT instrument. The split-spectrum amplitude-decorrelation angiography algorithm (SSADA) was used to compute three-dimensional optic disc angiography. A disc flow index was computed from four registered scans. Confocal scanning laser ophthalmoscopy (cSLO) was used to measure disc rim area, and stereo photography was used to evaluate cup/disc ratios. Wide field OCT scans over the discs were used to measure retinal nerve fiber layer (NFL) thickness. Main Outcome Measurements Variability was assessed by coefficient of variation (CV). Diagnostic accuracy was assessed by sensitivity and specificity. Comparisons between glaucoma and normal groups were analyzed by Wilcoxon rank-sum test. Correlations between disc flow index, structural assessments, and visual field (VF) parameters were assessed by linear regression. Results In normal discs, a dense microvascular network was visible on OCT angiography. This network was visibly attenuated in glaucoma subjects. The intra-visit repeatability, inter-visit reproducibility, and normal population variability of the optic disc flow index were 1.2%, 4.2%, and 5.0% CV respectively. The disc flow index was reduced by 25% in the glaucoma group (p = 0.003). Sensitivity and specificity were both 100% using an optimized cutoff. The flow index was highly correlated with VF pattern standard deviation (R2 = 0.752, p = 0.001). These correlations were significant even after accounting for age, cup/disc area ratio, NFL, and rim area. Conclusions OCT angiography, generated by the new SSADA algorithm, repeatably measures optic disc perfusion. OCT

  11. The Chemistry of Optical Discs.

    ERIC Educational Resources Information Center

    Birkett, David

    2002-01-01

    Explains the chemistry used in compact discs (CD), digital versatile discs (DVD), and magneto-optical (MO) discs focusing on the steps of initial creation of the mold, the molding of the polycarbonate, the deposition of the reflective layers, the lacquering of the CDs, and the bonding of DVDs. (Contains 15 references.) (YDS)

  12. Segmentation of optic disc and optic cup in retinal fundus images using shape regression.

    PubMed

    Sedai, Suman; Roy, Pallab K; Mahapatra, Dwarikanath; Garnavi, Rahil

    2016-08-01

    Glaucoma is one of the leading cause of blindness. The manual examination of optic cup and disc is a standard procedure used for detecting glaucoma. This paper presents a fully automatic regression based method which accurately segments optic cup and disc in retinal colour fundus image. First, we roughly segment optic disc using circular hough transform. The approximated optic disc is then used to compute the initial optic disc and cup shapes. We propose a robust and efficient cascaded shape regression method which iteratively learns the final shape of the optic cup and disc from a given initial shape. Gradient boosted regression trees are employed to learn each regressor in the cascade. A novel data augmentation approach is proposed to improve the regressors performance by generating synthetic training data. The proposed optic cup and disc segmentation method is applied on an image set of 50 patients and demonstrate high segmentation accuracy for optic cup and disc with dice metric of 0.95 and 0.85 respectively. Comparative study shows that our proposed method outperforms state of the art optic cup and disc segmentation methods.

  13. PATHOGENESIS OF OPTIC DISC EDEMA IN RAISED INTRACRANIAL PRESSURE

    PubMed Central

    Hayreh, Sohan Singh

    2015-01-01

    Optic disc edema in raised intracranial pressure was first described in 1853. Ever since, there has been a plethora of controversial hypotheses to explain its pathogenesis. I have explored the subject comprehensively by doing basic, experimental and clinical studies. My objective was to investigate the fundamentals of the subject, to test the validity of the previous theories, and finally, based on all these studies, to find a logical explanation for the pathogenesis. My studies included the following issues pertinent to the pathogenesis of optic disc edema in raised intracranial pressure: the anatomy and blood supply of the optic nerve, the roles of the sheath of the optic nerve, of the centripetal flow of fluids along the optic nerve, of compression of the central retinal vein, and of acute intracranial hypertension and its associated effects. I found that, contrary to some previous claims, an acute rise of intracranial pressure was not quickly followed by production of optic disc edema. Then, in rhesus monkeys, I produced experimentally chronic intracranial hypertension by slowly increasing in size space-occupying lesions, in different parts of the brain. Those produced raised cerebrospinal fluid pressure (CSFP) and optic disc edema, identical to those seen in patients with elevated CSFP. Having achieved that, I investigated various aspects of optic disc edema by ophthalmoscopy, stereoscopic color fundus photography and fluorescein fundus angiography, and light microscopic, electron microscopic, horseradish peroxidase and axoplasmic transport studies, and evaluated the effect of opening the sheath of the optic nerve on the optic disc edema. This latter study showed that opening the sheath resulted in resolution of optic disc edema on the side of the sheath fenestration, in spite of high intracranial CSFP, proving that a rise of CSFP in the sheath was the essential pre-requisite for the development of optic disc edema. I also investigated optic disc edema with

  14. [Clinical evaluation of the optic disc in glaucoma].

    PubMed

    Greslechner, R; Spiegel, D

    2016-10-01

    Glaucoma is defined as a progressive neuropathy of the optic nerve, characterized by specific changes of the optic disc, parapapillary region, and retinal nerve fiber layer. Characteristic glaucomatous changes of the optic disc, parapapillary region, and retinal nerve fiber layer are discussed and their ophthalmoscopic examination is described. A literature search in the PubMed database was conducted. A systematic step-by-step approach to a qualitative and quantitative ophthalmoscopic evaluation of the optic disc regarding glaucomatous damage is presented. A systematic, clinical, qualitative, and quantitative assessment of the optic disc can be performed with little effort and forms the basis for diagnosis and treatment of glaucoma.

  15. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    PubMed Central

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  16. Pathogenesis of optic disc edema in raised intracranial pressure.

    PubMed

    Hayreh, Sohan Singh

    2016-01-01

    Optic disc edema in raised intracranial pressure was first described in 1853. Ever since, there has been a plethora of controversial hypotheses to explain its pathogenesis. I have explored the subject comprehensively by doing basic, experimental and clinical studies. My objective was to investigate the fundamentals of the subject, to test the validity of the previous theories, and finally, based on all these studies, to find a logical explanation for the pathogenesis. My studies included the following issues pertinent to the pathogenesis of optic disc edema in raised intracranial pressure: the anatomy and blood supply of the optic nerve, the roles of the sheath of the optic nerve, of the centripetal flow of fluids along the optic nerve, of compression of the central retinal vein, and of acute intracranial hypertension and its associated effects. I found that, contrary to some previous claims, an acute rise of intracranial pressure was not quickly followed by production of optic disc edema. Then, in rhesus monkeys, I produced experimentally chronic intracranial hypertension by slowly increasing in size space-occupying lesions, in different parts of the brain. Those produced raised cerebrospinal fluid pressure (CSFP) and optic disc edema, identical to those seen in patients with elevated CSFP. Having achieved that, I investigated various aspects of optic disc edema by ophthalmoscopy, stereoscopic color fundus photography and fluorescein fundus angiography, and light microscopic, electron microscopic, horseradish peroxidase and axoplasmic transport studies, and evaluated the effect of opening the sheath of the optic nerve on the optic disc edema. This latter study showed that opening the sheath resulted in resolution of optic disc edema on the side of the sheath fenestration, in spite of high intracranial CSFP, proving that a rise of CSFP in the sheath was the essential pre-requisite for the development of optic disc edema. I also investigated optic disc edema with

  17. Archival-grade optical disc design and international standards

    NASA Astrophysics Data System (ADS)

    Fujii, Toru; Kojyo, Shinichi; Endo, Akihisa; Kodaira, Takuo; Mori, Fumi; Shimizu, Atsuo

    2015-09-01

    Optical discs currently on the market exhibit large variations in life span among discs, making them unsuitable for certain business applications. To assess and potentially mitigate this problem, we performed accelerated degradation testing under standard ISO conditions, determined the probable disc failure mechanisms, and identified the essential criteria necessary for a stable disc composition. With these criteria as necessary conditions, we analyzed the physical and chemical changes that occur in the disc components, on the basis of which we determined technological measures to reduce these degradation processes. By applying these measures to disc fabrication, we were able to develop highly stable optical discs.

  18. Dependence of optic disc parameters on disc area according to Heidelberg Retina Tomograph: Part II.

    NASA Astrophysics Data System (ADS)

    Machekhin, V.; Manaenkova, G.; Bondarenko, O.

    2007-05-01

    With the help of Heidelberg Retina Tomograph (HRT-II) optic disc parameters in 211 eyes of 115 healthy patients with refraction Em +/- 3,0 D and 96 eyes of 72 patients with myopia 3,5-14,0 D without any signs of glaucoma were studied. Analysis of optic disc parameters were carried out in 5 groups of patients according to disc area: less than 1,5 mm2, 1,5- 2,5 mm2, 2,5-3,0 mm2, 3,0-3,5 mm2 and more than 3,5 mm2. An accurate depending on disc area was revealed for all optic disc parameters in all sectors, which was manifested by increasing cup disc and rim disc (area and volume) and other parameters. We consider it is necessary to use the proper tables for right interpretation of received data for early diagnosis of glaucoma.

  19. Utility of Digital Stereo Images for Optic Disc Evaluation

    PubMed Central

    Ying, Gui-shuang; Pearson, Denise J.; Bansal, Mayank; Puri, Manika; Miller, Eydie; Alexander, Judith; Piltz-Seymour, Jody; Nyberg, William; Maguire, Maureen G.; Eledath, Jayan; Sawhney, Harpreet

    2010-01-01

    Purpose. To assess the suitability of digital stereo images for optic disc evaluations in glaucoma. Methods. Stereo color optic disc images in both digital and 35-mm slide film formats were acquired contemporaneously from 29 subjects with various cup-to-disc ratios (range, 0.26–0.76; median, 0.475). Using a grading scale designed to assess image quality, the ease of visualizing optic disc features important for glaucoma diagnosis, and the comparative diameters of the optic disc cup, experienced observers separately compared the primary digital stereo images to each subject's 35-mm slides, to scanned images of the same 35-mm slides, and to grayscale conversions of the digital images. Statistical analysis accounted for multiple gradings and comparisons and also assessed image formats under monoscopic viewing. Results. Overall, the quality of primary digital color images was judged superior to that of 35-mm slides (P < 0.001), including improved stereo (P < 0.001), but the primary digital color images were mostly equivalent to the scanned digitized images of the same slides. Color seemingly added little to grayscale optic disc images, except that peripapillary atrophy was best seen in color (P < 0.0001); both the nerve fiber layer (P < 0.0001) and the paths of blood vessels on the optic disc (P < 0.0001) were best seen in grayscale. The preference for digital over film images was maintained under monoscopic viewing conditions. Conclusions. Digital stereo optic disc images are useful for evaluating the optic disc in glaucoma and allow the application of advanced image processing applications. Grayscale images, by providing luminance distinct from color, may be informative for assessing certain features. PMID:20505199

  20. Progression of asymptomatic optic disc swelling to non-arteritic anterior ischaemic optic neuropathy.

    PubMed

    Subramanian, Prem S; Gordon, Lynn K; Bonelli, Laura; Arnold, Anthony C

    2017-05-01

    The time of onset of optic disc swelling in non-arteritic anterior ischaemic optic neuropathy (NAION) is not known, and it is commonly assumed to arise simultaneously with vision loss. Our goal is to report the presence and persistence of optic disc swelling without initial vision loss and its subsequent evolution to typical, symptomatic NAION. Clinical case series of patients with optic disc swelling and normal visual acuity and visual fields at initial presentation who progressed to have vision loss typical of NAION. All subjects underwent automated perimetry, disc photography and optic coherence tomography and/or fluorescein angiography to evaluate optic nerve function and perfusion. Four patients were found to have sectoral or diffuse optic disc swelling without visual acuity or visual field loss; the fellow eye of all four had either current or prior NAION or a 'disc at risk' configuration. Over several weeks of clinical surveillance, each patient experienced sudden onset of visual field and/or visual acuity loss typical for NAION. Current treatment options for NAION once vision loss occurs are limited and may not alter the natural history of the disorder. Subjects with NAION may have disc swelling for 2-10 weeks prior to the occurrence of visual loss, and with the development of new therapeutic agents, treatment at the time of observed disc swelling could prevent vision loss from NAION. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Anomalous optic discs in a patient with a Dandy-Walker cyst.

    PubMed

    Orcutt, J C; Bunt, A H

    1982-03-01

    A 19-month-old female infant with a Dandy-Walker cyst had anomalous optic discs, each of which appeared to divide to form an accessory optic nerve. The discs probably lie within the spectrum of anomalous discs including optic nerve aplasia and hypoplasia, megallopapillae, morning glory disc, optic disc dysplasia, and optic nerve colobomas. The association of anomalous optic discs with a Dandy-Walker cyst has not been previously recognized. The ocular and brain malformations in this patient likely occurred during the fourth to eighth week of gestation, when the retinal ganglion cell axons were penetrating the optic nerve, and the rhombic lips were enlarging in early cerebellar development. The etiology of these anomalies is not known; however, teratogens, sporadic events, and genetic disorders should be considered.

  2. Optic disc size and other parameters from optical coherence tomography in Vietnamese-Americans.

    PubMed

    Peng, Pai-Huei; Fu, Sheena; Nguyen, Ngoc; Porco, Travis; Lin, Shan C

    2011-08-01

    To investigate the optic disc parameters by optical coherence tomography (OCT) in Vietnamese with various types of glaucoma. Medical charts of Vietnamese and White patients within a single practice were reviewed. Disc and rim areas by OCT were compared among nonglaucoma controls, different types of glaucoma, and glaucoma suspect. The association of these parameters with demographic and ocular features was evaluated. Data from 1416 Vietnamese and 57 White patients were included. A larger mean disc area was observed in eyes with primary angle-closure glaucoma than in eyes with primary angle-closure and primary angle-closure suspect (both P<0.001). There was no association between disc size with central corneal thickness (P=0.051) and sex (P=0.155). Vietnamese patients with glaucoma and glaucoma suspicion had larger discs than diagnosis-matched Whites (P=0.043 and 0.021, respectively). Vietnamese patients with glaucoma seem to have larger optic discs than White patients. Central corneal thickness had no association with disc area in this study population.

  3. Optic disc pit with sectorial retinitis pigmentosa.

    PubMed

    Balikoglu-Yilmaz, Melike; Taskapili, Muhittin; Yilmaz, Tolga; Teke, Mehmet Yasin

    2013-01-01

    Sectorial retinitis pigmentosa (RP) and optic disc pit (ODP) are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, fluorescein angiography, and multifocal electroretinogram scans confirmed these clinical findings. Visual acuity was decreased due to an atrophic-appearing foveal lesion. No intervention was suggested because of the poor visual potential. To the best of our knowledge, the present study is the first to describe coexistent optic disc pit and sectorial RP in the superior and inferotemporal sectors covering the macula in the same eye with figures.

  4. Optic Disc Pit with Sectorial Retinitis Pigmentosa

    PubMed Central

    Taskapili, Muhittin; Yilmaz, Tolga; Teke, Mehmet Yasin

    2013-01-01

    Sectorial retinitis pigmentosa (RP) and optic disc pit (ODP) are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, fluorescein angiography, and multifocal electroretinogram scans confirmed these clinical findings. Visual acuity was decreased due to an atrophic-appearing foveal lesion. No intervention was suggested because of the poor visual potential. To the best of our knowledge, the present study is the first to describe coexistent optic disc pit and sectorial RP in the superior and inferotemporal sectors covering the macula in the same eye with figures. PMID:23781365

  5. Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.

    PubMed

    Richter, Grace M; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Chopra, Vikas; Greenfield, David S; Varma, Rohit; Schuman, Joel S; Huang, David

    2016-08-01

    To report diagnostic accuracy of optical coherence tomography (OCT) disc variables using both time-domain (TD) and Fourier-domain (FD) OCT, and to improve the use of OCT disc variable measurements for glaucoma diagnosis through regression analyses that adjust for optic disc size and axial length-based magnification error. Observational, cross-sectional. In total, 180 normal eyes of 112 participants and 180 eyes of 138 participants with perimetric glaucoma from the Advanced Imaging for Glaucoma Study. Diagnostic variables evaluated from TD-OCT and FD-OCT were: disc area, rim area, rim volume, optic nerve head volume, vertical cup-to-disc ratio (CDR), and horizontal CDR. These were compared with overall retinal nerve fiber layer thickness and ganglion cell complex. Regression analyses were performed that corrected for optic disc size and axial length. Area-under-receiver-operating curves (AUROC) were used to assess diagnostic accuracy before and after the adjustments. An index based on multiple logistic regression that combined optic disc variables with axial length was also explored with the aim of improving diagnostic accuracy of disc variables. Comparison of diagnostic accuracy of disc variables, as measured by AUROC. The unadjusted disc variables with the highest diagnostic accuracies were: rim volume for TD-OCT (AUROC=0.864) and vertical CDR (AUROC=0.874) for FD-OCT. Magnification correction significantly worsened diagnostic accuracy for rim variables, and while optic disc size adjustments partially restored diagnostic accuracy, the adjusted AUROCs were still lower. Axial length adjustments to disc variables in the form of multiple logistic regression indices led to a slight but insignificant improvement in diagnostic accuracy. Our various regression approaches were not able to significantly improve disc-based OCT glaucoma diagnosis. However, disc rim area and vertical CDR had very high diagnostic accuracy, and these disc variables can serve to complement

  6. Optic disc detection and boundary extraction in retinal images.

    PubMed

    Basit, A; Fraz, Muhammad Moazam

    2015-04-10

    With the development of digital image processing, analysis and modeling techniques, automatic retinal image analysis is emerging as an important screening tool for early detection of ophthalmologic disorders such as diabetic retinopathy and glaucoma. In this paper, a robust method for optic disc detection and extraction of the optic disc boundary is proposed to help in the development of computer-assisted diagnosis and treatment of such ophthalmic disease. The proposed method is based on morphological operations, smoothing filters, and the marker controlled watershed transform. Internal and external markers are used to first modify the gradient magnitude image and then the watershed transformation is applied on this modified gradient magnitude image for boundary extraction. This method has shown significant improvement over existing methods in terms of detection and boundary extraction of the optic disc. The proposed method has optic disc detection success rate of 100%, 100%, 100% and 98.9% for the DRIVE, Shifa, CHASE_DB1, and DIARETDB1 databases, respectively. The optic disc boundary detection achieved an average spatial overlap of 61.88%, 70.96%, 45.61%, and 54.69% for these databases, respectively, which are higher than currents methods.

  7. Medical Information on Optical Disc*

    PubMed Central

    Schipma, Peter B.; Cichocki, Edward M.; Ziemer, Susan M.

    1987-01-01

    Optical discs may permit a revolutionary change in the distribution and use of medical information. A single compact disc, similar in size to that used for digital audio recording, can contain over 500 million characters of information that is accessible by a Personal Computer. These discs can be manufactured at a cost lower than that of print on paper, at reasonable volumes. Software can provide the health care professional with nearly instantaneous access to the information. Thus, for the first time, the opportunity exists to have large local medical information collections. This paper describes an application of this technology in the field of Oncology.

  8. Study of the Radial Peripapillary Capillary Network in Congenital Optic Disc Anomalies With Optical Coherence Tomography Angiography.

    PubMed

    Cennamo, Gilda; Rossi, Claudia; Ruggiero, Pasquale; de Crecchio, Giuseppe; Cennamo, Giovanni

    2017-04-01

    To evaluate the radial peripapillary capillary network with optical coherence tomography angiography (angio-OCT) in morning glory syndrome (MGS), optic disc colobomas, and optic disc pits, and to explore possible correlations between the neural vascular structure and the pathogenesis of congenital optic disc anomalies. Prospective observational comparative case series. Fifteen eyes of 15 patients with congenital optic disc anomalies were enrolled in this study. All patients underwent angio-OCT. The scans were centered on optic discs. The mean age at presentation was 33 years (range: 19-50 years). Congenital optic disc anomalies were identified in all 15 eyes. Three eyes had the characteristic funduscopic signs of MGS, and angio-OCT scans of the peripapillary retina revealed a dense microvascular network. Optic disc colobomas were found in 5 eyes, and the characteristic funduscopic signs of optic pits were found in 7 eyes. Angio-OCT showed the absence of a radial peripapillary microvascular network in these 12 eyes. The finding that angio-OCT scans confirmed the presence of a peripapillary microvascular network only in MGS cases supports the hypothesis that a primary neuroectodermal abnormality and a secondary mesenchymal abnormality leads to MGS. Angio-OCT is a safe, rapid imaging technique that could shed light on the pathogenesis of rare diseases of the optic disc. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Ensuring long-term reliability of the data storage on optical disc

    NASA Astrophysics Data System (ADS)

    Chen, Ken; Pan, Longfa; Xu, Bin; Liu, Wei

    2008-12-01

    "Quality requirements and handling regulation of archival optical disc for electronic records filing" is released by The State Archives Administration of the People's Republic of China (SAAC) on its network in March 2007. This document established a complete operative managing process for optical disc data storage in archives departments. The quality requirements of the optical disc used in archives departments are stipulated. Quality check of the recorded disc before filing is considered to be necessary and the threshold of the parameter of the qualified filing disc is set down. The handling regulations for the staffs in the archives departments are described. Recommended environment conditions of the disc preservation, recording, accessing and testing are presented. The block error rate of the disc is selected as main monitoring parameter of the lifetime of the filing disc and three classes pre-alarm lines are created for marking of different quality check intervals. The strategy of monitoring the variation of the error rate curve of the filing discs and moving the data to a new disc or a new media when the error rate of the disc reaches the third class pre-alarm line will effectively guarantee the data migration before permanent loss. Only when every step of the procedure is strictly implemented, it is believed that long-term reliability of the data storage on optical disc for archives departments can be effectively ensured.

  10. Prediction of functional loss in glaucoma from progressive optic disc damage.

    PubMed

    Medeiros, Felipe A; Alencar, Luciana M; Zangwill, Linda M; Bowd, Christopher; Sample, Pamela A; Weinreb, Robert N

    2009-10-01

    To evaluate the ability of progressive optic disc damage detected by assessment of longitudinal stereophotographs to predict future development of functional loss in those with suspected glaucoma. The study included 639 eyes of 407 patients with suspected glaucoma followed up for an average of 8.0 years with annual standard automated perimetry visual field and optic disc stereophotographs. All patients had normal and reliable standard automated perimetry results at baseline. Conversion to glaucoma was defined as development of 3 consecutive abnormal visual fields during follow-up. Presence of progressive optic disc damage was evaluated by grading longitudinally acquired simultaneous stereophotographs. Other predictive factors included age, intraocular pressure, central corneal thickness, pattern standard deviation, and baseline stereophotograph grading. Hazard ratios for predicting visual field loss were obtained by extended Cox models, with optic disc progression as a time-dependent covariate. Predictive accuracy was evaluated using a modified R(2) index. Progressive optic disc damage had a hazard ratio of 25.8 (95% confidence interval, 16.0-41.7) and was the most important risk factor for development of visual field loss with an R(2) of 79%. The R(2)s for other predictive factors ranged from 6% to 26%. Presence of progressive optic disc damage on stereophotographs was a highly predictive factor for future development of functional loss in glaucoma. These findings suggest the importance of careful monitoring of the optic disc appearance and a potential role for longitudinal assessment of the optic disc as an end point in clinical trials and as a reference for evaluation of diagnostic tests in glaucoma.

  11. Optic nerve axons and acquired alterations in the appearance of the optic disc.

    PubMed Central

    Wirtschafter, J D

    1983-01-01

    The pathophysiologic events in optic nerve axons have recently been recognized as crucial to an understanding of clinically significant acquired alterations in the ophthalmoscopic appearance of the optic disc. Stasis and related abnormalities of axonal transport appear to explain most aspects of optic nerve head swelling, including optic disc drusen and retinal cottonwool spots. Loss of axoplasm and axonal death can be invoked to interpret optic disc pallor, thinning and narrowing of rim tissue, changes in the size and outline of the optic cup, laminar dots, atrophy of the retinal nerve fiber layer, and acquired demyelination and myelination of the retinal nerve fiber layer. It is speculated that the axons may also play a role in the mechanical support of the lamina cribrosa in resisting the pressure gradient across the pars scleralis of the optic nerve head. Axons and their associated glial cells may be involved in those cases where "reversibility" of cupping of the optic disc has been reported. The structure, physiology, and experimental pathologic findings of the optic nerve head have been reviewed. Many aspects concerning the final anatomic appearance of the optic nerve head have been explained. However, many questions remain concerning the intermediate mechanisms by which increased intracranial pressure retards the various components of axonal transport in papilledema and by which increased IOP causes axonal loss in glaucoma. Investigation of the molecular biology of axonal constituents and their responses to abnormalities in their physical and chemical milieu could extend our understanding of the events that result from mechanical compression and local ischemia. Moreover, we have identified a need to further explore the role of axons in the pathophysiology of optic disc cupping. Images FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 11 FIGURE 12 FIGURE 13 PMID:6203209

  12. Line-driven ablation of circumstellar discs - I. Optically thin decretion discs of classical Oe/Be stars.

    PubMed

    Kee, Nathaniel Dylan; Owocki, Stanley; Sundqvist, J O

    2016-05-21

    The extreme luminosities of massive, hot OB stars drive strong stellar winds through line-scattering of the star's UV continuum radiation. For OB stars with an orbiting circumstellar disc, we explore here the effect of such line-scattering in driving an ablation of material from the disc's surface layers, with initial focus on the marginally optically thin decretion discs of classical Oe and Be stars. For this we apply a multidimensional radiation-hydrodynamics code that assumes simple optically thin ray tracing for the stellar continuum, but uses a multiray Sobolev treatment of the line transfer; this fully accounts for the efficient driving by non-radial rays, due to desaturation of line-absorption by velocity gradients associated with the Keplerian shear in the disc. Results show a dense, intermediate-speed surface ablation, consistent with the strong, blueshifted absorption of UV wind lines seen in Be shell stars that are observed from near the disc plane. A key overall result is that, after an initial adjustment to the introduction of the disc, the asymptotic disc destruction rate is typically just an order-unity factor times the stellar wind mass-loss rate. For optically thin Be discs, this leads to a disc destruction time of order months to years, consistent with observationally inferred disc decay times. The much stronger radiative forces of O stars reduce this time to order days, making it more difficult for decretion processes to sustain a disc in earlier spectral types, and so providing a natural explanation for the relative rarity of Oe stars in the Galaxy. Moreover, the decrease in line-driving at lower metallicity implies both a reduction in the winds that help spin-down stars from near-critical rotation, and a reduction in the ablation of any decretion disc; together these provide a natural explanation for the higher fraction of classical Be stars, as well as the presence of Oe stars, in the lower metallicity Magellanic Clouds. We conclude with a

  13. High-Resolution Imaging of the Optic Nerve and Retina in Optic Nerve Hypoplasia

    PubMed Central

    Pilat, Anastasia; Sibley, Daniel; McLean, Rebecca J.; Proudlock, Frank A.; Gottlob, Irene

    2015-01-01

    Purpose To investigate the optic nerve and macular morphology in patients with optic nerve hypoplasia (ONH) using spectral-domain optical coherence tomography (SD OCT). Design Prospective, cross-sectional, observational study. Subjects A total of 16 participants with ONH (10 female and 6 male; mean age, 17.2 years; 6 bilateral involvement) and 32 gender-, age-, ethnicity-, and refraction-matched healthy controls. Methods High-resolution SD OCT (Copernicus [Optopol Technology S.A., Zawiercie, Poland], 3 μm resolution) and handheld SD OCT (Bioptigen Inc [Research Triangle Park, NC], 2.6 μm resolution) devices were used to acquire horizontal scans through the center of the optic disc and macula. Main Outcome Measures Horizontal optic disc/cup and rim diameters, cup depth, peripapillary retinal nerve fiber layer (RNFL), and thickness of individual retinal layers in participants with ONH and in controls. Results Patients with ONH had significantly smaller discs (P < 0.03 and P < 0.001 compared with unaffected eye and healthy controls, respectively), horizontal cup diameter (P < 0.02 for both), and cup depth (P < 0.02 and P < 0.01, respectively). In the macula, significantly thinner RNFL (nasally), ganglion cell layer (GCL) (nasally and temporally), inner plexiform layer (IPL) (nasally), outer nuclear layer (ONL) (nasally), and inner segment (centrally and temporally) were found in patients with ONH compared with the control group (P < 0.05 for all comparisons). Continuation of significantly thicker GCL, IPL, and outer plexiform layer in the central retinal area (i.e., foveal hypoplasia) was found in more than 80% of patients with ONH. Clinically unaffected fellow eyes of patients with ONH showed mild features of underdevelopment. Visual acuity and presence of septo-optic dysplasia were associated with changes in GCL and IPL. Sensitivity and specificity for the detection of ONH based on disc and retinal optical coherence tomography (OCT) parameters were >80

  14. Noonan's syndrome with keratoconus and optic disc coloboma.

    PubMed

    Ascaso, F J; Del Buey, M A; Huerva, V; Latre, B; Palomar, A

    1993-01-01

    We report the case of a 14-year-old girl with multiple findings characteristic of Noonan's syndrome, including short stature, mild mental retardation, facial, skeletal and renal abnormalities. In addition, ophthalmic examination revealed a keratoconus in the left eye and a right optic disc coloboma. To date, only two cases of Noonan's syndrome with keratoconus have been reported, and this is the second case of this syndrome with optic disc coloboma. To our knowledge, this is the first report of Noonan's syndrome associated with unilateral keratoconus and contralateral optic disc coloboma. In view of the large number of patients with Noonan's syndrome reported to date and the rarity of these ocular abnormalities, it is most likely that this association is fortuitous. Ocular findings reported in patients with Noonan's syndrome are reviewed.

  15. Influence of height, weight, and body mass index on optic disc parameters.

    PubMed

    Zheng, Yingfeng; Cheung, Carol Y L; Wong, Tien Y; Mitchell, Paul; Aung, Tin

    2010-06-01

    To examine the influence of body height, body weight, and body mass index (BMI) on optic disc parameters in a population-based study. The Singapore Malay Eye Study examined 3280 persons of Malay ethnicity, aged 40 to 80 years, of whom 2329 (71.0%) had reliable retinal scanning confocal laser tomography images for analyses. Intraocular pressure (IOP) was ascertained by Goldmann applanation tonometry. Body height and weight were measured with standardized protocols; BMI was calculated as weight (kilograms)/height squared (meters). Sociodemographic information was collected in an interviewer-administered questionnaire. In univariate analyses, body height, weight, and BMI were significantly associated with optic cup area, rim area, and cup-to-disc area ratio (all with P < 0.05) but none of the anthropometric parameters was significantly associated with optic disc area (all with P > 0.05). In multiple regression analyses after adjustment for age, sex, optic disc size, axial length, education, family income, and IOP, each SD increase in body height was associated with a 0.042-mm(2) decrease in optic rim area and a 0.020 increase in optic cup-to-disc area ratio; each SD decrease in body weight was associated with a 0.013-mm(2) decrease in optic rim area and a 0.010 increase in optic cup-to-disc ratio; and each SD decrease in BMI was associated with a 0.021-mm(2) decrease in optic rim area and a 0.010 increase in optic cup-to-disc ratio. Persons who are taller or have lower BMI have a smaller neuroretinal rim area and a larger optic cup-to-disc area ratio.

  16. Discus: investigating subjective judgment of optic disc damage.

    PubMed

    Denniss, Jonathan; Echendu, Damian; Henson, David B; Artes, Paul H

    2011-01-01

    To describe a software package (Discus) for investigating clinicians' subjective assessment of optic disc damage [diagnostic accuracy in detecting visual field (VF) damage, decision criteria, and agreement with a panel of experts] and to provide reference data from a group of expert observers. Optic disc images were selected from patients with manifest or suspected glaucoma or ocular hypertension who attended the Manchester Royal Eye Hospital. Eighty images came from eyes without evidence of VF loss in at least four consecutive tests (VF negatives), and 20 images from eyes with repeatable VF loss (VF positives). Software was written to display these images in randomized order, for up to 60 s. Expert observers (n = 12) rated optic disc damage on a 5-point scale (definitely healthy, probably healthy, not sure, probably damaged, and definitely damaged). Optic disc damage as determined by the expert observers predicted VF loss with less than perfect accuracy (mean area under receiver-operating characteristic curve, 0.78; range, 0.72 to 0.85). When the responses were combined across the panel of experts, the area under receiver-operating characteristic curve reached 0.87, corresponding to a sensitivity of ∼60% at 90% specificity. Although the observers' performances were similar, there were large differences between the criteria they adopted (p < 0.001), even though all observers had been given identical instructions. Discus provides a simple and rapid means for assessing important aspects of optic disc interpretation. The data from the panel of expert observers provide a reference against which students, trainees, and clinicians may compare themselves. The program and the analyses described in this article are freely accessible from http://www.discusproject.blogspot.com/.

  17. Line-driven ablation of circumstellar discs – I. Optically thin decretion discs of classical Oe/Be stars

    PubMed Central

    Kee, Nathaniel Dylan; Owocki, Stanley; Sundqvist, J. O.

    2016-01-01

    The extreme luminosities of massive, hot OB stars drive strong stellar winds through line-scattering of the star's UV continuum radiation. For OB stars with an orbiting circumstellar disc, we explore here the effect of such line-scattering in driving an ablation of material from the disc's surface layers, with initial focus on the marginally optically thin decretion discs of classical Oe and Be stars. For this we apply a multidimensional radiation-hydrodynamics code that assumes simple optically thin ray tracing for the stellar continuum, but uses a multiray Sobolev treatment of the line transfer; this fully accounts for the efficient driving by non-radial rays, due to desaturation of line-absorption by velocity gradients associated with the Keplerian shear in the disc. Results show a dense, intermediate-speed surface ablation, consistent with the strong, blueshifted absorption of UV wind lines seen in Be shell stars that are observed from near the disc plane. A key overall result is that, after an initial adjustment to the introduction of the disc, the asymptotic disc destruction rate is typically just an order-unity factor times the stellar wind mass-loss rate. For optically thin Be discs, this leads to a disc destruction time of order months to years, consistent with observationally inferred disc decay times. The much stronger radiative forces of O stars reduce this time to order days, making it more difficult for decretion processes to sustain a disc in earlier spectral types, and so providing a natural explanation for the relative rarity of Oe stars in the Galaxy. Moreover, the decrease in line-driving at lower metallicity implies both a reduction in the winds that help spin-down stars from near-critical rotation, and a reduction in the ablation of any decretion disc; together these provide a natural explanation for the higher fraction of classical Be stars, as well as the presence of Oe stars, in the lower metallicity Magellanic Clouds. We conclude with a

  18. Design and implementation of optical system for Placido-disc topography

    NASA Astrophysics Data System (ADS)

    Sui, Chenghua; Wo, Shengjie; Cai, Pinggen; Gao, Nan; Xu, Danyang; Han, Yonghao; Du, Chunnian

    2017-11-01

    Corneal topography provides powerful support in the diagnosis and treatment of corneal disease by displaying the corneal surface topography in data or image format. To realize the precise detection of corneal surface topography, an optical system for the corneal topography that is based on a Placido disc is designed, which includes a ring distribution on a Placido disc, an imaging system and a collimating illumination system. First, a mathematical model that is based on the corneal topography working principles is established with MATLAB to determine the distribution of white-and-black rings on the Placido disc, in which the ellipsoid facial rings-target of the Placido disc is utilized. Second, the imaging lens structure is designed and optimized by Zemax software. Last, the collimating illumination lens structure is designed by paraxial ray trace equations. The quality of the corneal topography, which is based on our designed optical system, is evaluated. The high-contrast image of uniformly distributed white-and-black rings is observed through the CCD camera. Our optical system for the corneal topography has high precision, with a measuring region of the cornea with a diameter of approximately 10 mm. Therefore, the creation of this optical system offers guidance for designing and improving the optical system of Placido-disc topography.

  19. Optical Coherence Tomography Angiography in Optic Disc Swelling.

    PubMed

    Fard, Masoud Aghsaei; Jalili, Jalil; Sahraiyan, Alireza; Khojasteh, Hassan; Hejazi, Marjane; Ritch, Robert; Subramanian, Prem S

    2018-05-04

    To compare optical coherence tomography angiography (OCT-A) of peripapillary total vasculature and capillaries in patients with optic disc swelling. Cross-sectional study. Twenty nine eyes with acute nonarteritic anterior ischemic optic neuropathy (NAION), 44 eyes with papilledema, 8 eyes with acute optic neuritis, and 48 eyes of normal subjects were imaged using OCT-A. Peripapillary total vasculature information was recorded using a commercial vessel density map. Customized image analysis with major vessel removal was also used to measure whole-image capillary density and peripapillary capillary density (PCD). Mixed models showed that the peripapillary total vasculature density values were significantly lower in NAION eyes, followed by papilledema eyes and control eyes, using commercial software (P < .0001 for all comparisons). The customized software also showed significantly lower PCD of NAION eyes compared with papilledema eyes (all P < .001), but did not show significant differences between papilledema and control subjects. Our software showed significantly lower whole image and PCD in eyes with optic neuritis than papilledema. There was no significant difference between NAION and optic neuritis using our software. The area under the receiver operating curves for discriminating NAION from papilledema eyes and optic neuritis from papilledema eyes was highest for whole-image capillary density (0.94 and 0.80, respectively) with our software, followed by peripapillary total vasculature (0.9 and 0.74, respectively ) with commercial software. OCT-A is helpful to distinguish NAION and papillitis from papilledema. Whole-image capillary density had the greatest diagnostic accuracy for differentiating disc swelling. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Comparative study of optic disc measurement by Copernicus optical coherence tomography and Heidelberg retinal tomography.

    PubMed

    Yang, Qing-Song; Yu, Ya-Jie; Li, Shu-Ning; Liu, Juan; Hao, Ying-Juan

    2012-08-01

    Copernicus optical coherence tomography (SOCT) is a new, ultra high-speed and high-resolution instrument available for clinical evaluation of optic nerve. The purpose of the study was to compare the agreements between SOCT and Heidelberg retinal tomography (HRT). A total of 44 healthy normal volunteers were recruited in this study. One eye in each subject was selected randomly. Agreement between SOCT and HRT-3 in measuring optic disc area was assessed using Bland-Altman plots. Relationships between measurements of optic nerve head parameter obtained by SOCT and HRT-3 were assessed by Pearson correlation. There was no significant difference in the average cup area (0.306 vs. 0.355 mm, P = 0.766), cup volume (0.158 vs. 0.130 mm, P = 0.106) and cup/disc ration (0.394 vs. 0.349 mm, P = 0.576) measured by the two instruments. However, other optic disc parameters from SOCT were significantly lower compared with HRT-3. The Bland-Altman plot revealed good agreement of cup area and cup volume measured by SOCT and HRT-3. Bad agreement of disc area, rim area, rim volume and cup/disc ratio were found between SOCT and HRT-3. The highest correlations between the two instruments were observed for cup area (r(2) = 0.783, P = 0.000) and cup/disc ratio (r(2) = 0.669, P = 0.000), whereas the lowest correlation was observed for disc area (r(2) = 0.100, P = 0.037), rim area (r(2) = 0.275, P = 0.000), cup volume (r(2) = 0.005, P = 0.391) and rim volume (r(2) = 0.021, P = 0.346). There were poor agreements between SOCT and HRT-3 for measurement of optic nerve parameters except cup area and cup volume. Measurement results of the two instruments are not interchangeable.

  1. Topographic optic disc analysis by Heidelberg retinal tomography in ocular Behcet's disease.

    PubMed

    Berker, Nilufer; Elgin, Ufuk; Ozdal, Pinar; Batman, Aygen; Soykan, Emel; Ozkan, Seyhan S

    2007-09-01

    To compare the topographic characteristics of the optic discs in patients with severe and mild ocular Behçet's disease by using Heidelberg retinal tomographaphy (HRT). This prospective study included 47 eyes of 47 patients with ocular BD who were being followed-up at the Uveitis Clinic of the Ankara Ulucanlar Eye Research Hospital, Ankara, Turkey. The patients were divided into two groups. Group 1 consisted of 21 eyes with mild uveitis, and group 2 consisted of 26 eyes with severe uveitis. All patients underwent topographic optic disc analysis by HRT II, and the quantitative optic disc parameters of both groups were compared by non-parametric Mann-Whitney U test. The mean cup volume, rim volume, cup area, disc area and cup depth in group 1 were found to be statistically significantly greater than those in group 2 (p<0.0001, p = 0.03, p = 0.021, p = 0.01 and p = 0.017, respectively), while the difference between the mean cup-to-disc ratios in group 1 and group 2 were found to be statistically insignificant (p = 0.148). A relationship was found between the severity of ocular BD and optic disc topography determined by HRT. In eyes with smaller optic discs, uveitis was observed to have a more severe course with more frequent relapses than those with larger discs.

  2. The Location of the Deepest Point of the Eyeball Determines the Optic Disc Configuration.

    PubMed

    Kim, Yong Chan; Jung, Younhea; Park, Hae-Young Lopilly; Park, Chan Kee

    2017-07-19

    Tilted and rotated appearances are hallmarks of the myopic optic disc. As the eyeball grows axially, the posterior pole elongates not only globally but in a localized manner as well. In this process, the optic disc is pulled towards the deepest point of the elongated eyeball, which might result in a change in optic disc configuration. Thus, we hypothesized that analyzing the variation of posterior pole contour can play a major role in understanding optic disc configuration in myopic subjects. By analyzing consecutive images of swept source OCT coronal sections at the posterior pole, the deepest interface between Bruch's membrane and the choroid could be identified as the deepest point of the eyeball (DPE). The location and the properties of the DPE differed significantly between the 125 eyes of non-glaucomatous myopic group and the 40 eyes of non-glaucomatous emmetropic group classified based on 24 mm axial length. The results suggested that the larger disc to DPE angle and the larger disc to DPE depth strongly predicts the optic disc torsion degree and the optic disc tilt. Our findings suggest that identifying the posterior pole profile plays a major role in understanding the optic disc alterations found in myopic subjects.

  3. High-Density Near-Field Optical Disc Recording

    NASA Astrophysics Data System (ADS)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Ide, Naoki; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2005-05-01

    We developed a high-density near-field optical recording disc system using a solid immersion lens. The near-field optical pick-up consists of a solid immersion lens with a numerical aperture of 1.84. The laser wavelength for recording is 405 nm. In order to realize the near-field optical recording disc, we used a phase-change recording media and a molded polycarbonate substrate. A clear eye pattern of 112 GB capacity with 160 nm track pitch and 50 nm bit length was observed. The equivalent areal density is 80.6 Gbit/in2. The bottom bit error rate of 3 tracks-write was 4.5× 10-5. The readout power margin and the recording power margin were ± 30.4% and ± 11.2%, respectively.

  4. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    PubMed

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  5. [The Autocad system for planimetric study of the optic disc in glaucoma: technique and reproducibility study].

    PubMed

    Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B

    2001-09-01

    To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.

  6. Optical Disc Applications in Libraries.

    ERIC Educational Resources Information Center

    Andre, Pamela Q. J.

    1989-01-01

    Discusses a variety of library applications of optical disc storage technology, including CD-ROM, digital videodisc, and WORM. Research and development projects at the Library of Congress, National Library of Medicine, and National Agricultural Library are described, products offered by library networks are reviewed, and activities in academic and…

  7. Optical effects related to Keplerian discs orbiting Kehagias-Sfetsos naked singularities

    NASA Astrophysics Data System (ADS)

    Stuchlík, Zdeněk; Schee, Jan

    2014-10-01

    We demonstrate possible optical signatures of the Kehagias-Sfetsos (KS) naked singularity spacetimes representing a spherically symmetric vacuum solution of the modified Hořava gravity. In such spacetimes, accretion structures significantly different from those present in standard black hole spacetimes occur due to the ‘antigravity’ effect, which causes an internal static sphere surrounded by Keplerian discs. We focus our attention on the optical effects related to the Keplerian accretion discs, constructing the optical appearance of the Keplerian discs, the spectral continuum due to their thermal radiation, and the spectral profiled lines generated in the innermost parts of such discs. The KS naked singularity signature is strongly encoded in the characteristics of predicted optical effects, especially in cases where the spectral continuum and spectral lines are profiled by the strong gravity of the spacetimes due to the vanishing region of the angular velocity gradient influencing the effectiveness of the viscosity mechanism. We can conclude that optical signatures of KS naked singularities can be well distinguished from the signatures of standard black holes.

  8. Optic disc coloboma in two nigerian siblings: Case report and review of literature.

    PubMed

    Babalola, Y O; Olawoye, O O; Idam, P O

    2017-11-01

    We report two cases of bilateral asymmetric optic disc coloboma (ODC) in siblings. The index patient is a 9-year-old Nigerian girl with severe cognitive deficit who presented with a poor vision of 3 years' duration. She had a history of childhood febrile convulsions and delayed developmental milestones. Her visual acuity could not be assessed because she had a cognitive deficit and expressive aphasia. Ocular examination revealed a very large excavated right optic disc with only a strip of remnant neuro-retinal rim superiorly, and a smaller left optic disc with inferior disc excavation, superior wedge of the pink neuro-retinal rim as well as a temporal optic disc pit. No systemic features of syndromes associated with ODCs and intellectual disability were present in both patients. The younger sibling an 8-year-old girl later presented to the eye clinic with a 5-month history of poor vision in the left eye. Ocular examination revealed visual acuity of 6/6 in the right eye and counting fingers in the left eye. Dilated binocular indirect ophthalmoscopy revealed a right large excavated colobomatous disc and a left small disc with infero-temporal disc coloboma.

  9. Fast localization of optic disc and fovea in retinal images for eye disease screening

    NASA Astrophysics Data System (ADS)

    Yu, H.; Barriga, S.; Agurto, C.; Echegaray, S.; Pattichis, M.; Zamora, G.; Bauman, W.; Soliz, P.

    2011-03-01

    Optic disc (OD) and fovea locations are two important anatomical landmarks in automated analysis of retinal disease in color fundus photographs. This paper presents a new, fast, fully automatic optic disc and fovea localization algorithm developed for diabetic retinopathy (DR) screening. The optic disc localization methodology comprises of two steps. First, the OD location is identified using template matching and directional matched filter. To reduce false positives due to bright areas of pathology, we exploit vessel characteristics inside the optic disc. The location of the fovea is estimated as the point of lowest matched filter response within a search area determined by the optic disc location. Second, optic disc segmentation is performed. Based on the detected optic disc location, a fast hybrid level-set algorithm which combines the region information and edge gradient to drive the curve evolution is used to segment the optic disc boundary. Extensive evaluation was performed on 1200 images (Messidor) composed of 540 images of healthy retinas, 431 images with DR but no risk of macular edema (ME), and 229 images with DR and risk of ME. The OD location methodology obtained 98.3% success rate, while fovea location achieved 95% success rate. The average mean absolute distance (MAD) between the OD segmentation algorithm and "gold standard" is 10.5% of estimated OD radius. Qualitatively, 97% of the images achieved Excellent to Fair performance for OD segmentation. The segmentation algorithm performs well even on blurred images.

  10. Combined in-depth, 3D, en face imaging of the optic disc, optic disc pits and optic disc pit maculopathy using swept-source megahertz OCT at 1050 nm.

    PubMed

    Maertz, Josef; Kolb, Jan Philip; Klein, Thomas; Mohler, Kathrin J; Eibl, Matthias; Wieser, Wolfgang; Huber, Robert; Priglinger, Siegfried; Wolf, Armin

    2018-02-01

    To demonstrate papillary imaging of eyes with optic disc pits (ODP) or optic disc pit associated maculopathy (ODP-M) with ultrahigh-speed swept-source optical coherence tomography (SS-OCT) at 1.68 million A-scans/s. To generate 3D-renderings of the papillary area with 3D volume-reconstructions of the ODP and highly resolved en face images from a single densely-sampled megahertz-OCT (MHz-OCT) dataset for investigation of ODP-characteristics. A 1.68 MHz-prototype SS-MHz-OCT system at 1050 nm based on a Fourier-domain mode-locked laser was employed to acquire high-definition, 3D datasets with a dense sampling of 1600 × 1600 A-scans over a 45° field of view. Six eyes with ODPs, and two further eyes with glaucomatous alteration or without ocular pathology are presented. 3D-rendering of the deep papillary structures, virtual 3D-reconstructions of the ODPs and depth resolved isotropic en face images were generated using semiautomatic segmentation. 3D-rendering and en face imaging of the optic disc, ODPs and ODP associated pathologies showed a broad spectrum regarding ODP characteristics. Between individuals the shape of the ODP and the appending pathologies varied considerably. MHz-OCT en face imaging generates distinct top-view images of ODPs and ODP-M. MHz-OCT generates high resolution images of retinal pathologies associated with ODP-M and allows visualizing ODPs with depths of up to 2.7 mm. Different patterns of ODPs can be visualized in patients for the first time using 3D-reconstructions and co-registered high-definition en face images extracted from a single densely sampled 1050 nm megahertz-OCT (MHz-OCT) dataset. As the immediate vicinity to the SAS and the site of intrapapillary proliferation is located at the bottom of the ODP it is crucial to image the complete structure and the whole depth of ODPs. Especially in very deep pits, where non-swept-source OCT fails to reach the bottom, conventional swept-source devices and the MHz-OCT alike are feasible

  11. Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma

    PubMed Central

    Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki

    2015-01-01

    Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580

  12. A novel method for retinal optic disc detection using bat meta-heuristic algorithm.

    PubMed

    Abdullah, Ahmad S; Özok, Yasa Ekşioğlu; Rahebi, Javad

    2018-05-09

    Normally, the optic disc detection of retinal images is useful during the treatment of glaucoma and diabetic retinopathy. In this paper, the novel preprocessing of a retinal image with a bat algorithm (BA) optimization is proposed to detect the optic disc of the retinal image. As the optic disk is a bright area and the vessels that emerge from it are dark, these facts lead to the selected segments being regions with a great diversity of intensity, which does not usually happen in pathological regions. First, in the preprocessing stage, the image is fully converted into a gray image using a gray scale conversion, and then morphological operations are implemented in order to remove dark elements such as blood vessels, from the images. In the next stage, a bat algorithm (BA) is used to find the optimum threshold value for the optic disc location. In order to improve the accuracy and to obtain the best result for the segmented optic disc, the ellipse fitting approach was used in the last stage to enhance and smooth the segmented optic disc boundary region. The ellipse fitting is carried out using the least square distance approach. The efficiency of the proposed method was tested on six publicly available datasets, MESSIDOR, DRIVE, DIARETDB1, DIARETDB0, STARE, and DRIONS-DB. The optic disc segmentation average overlaps and accuracy was in the range of 78.5-88.2% and 96.6-99.91% in these six databases. The optic disk of the retinal images was segmented in less than 2.1 s per image. The use of the proposed method improved the optic disc segmentation results for healthy and pathological retinal images in a low computation time. Graphical abstract ᅟ.

  13. Analysis of optic disc change using the heidelberg retina tomograph in an acquired pit of the optic nerve.

    PubMed

    Oh, Joo Youn; Park, Ki Ho

    2004-01-01

    A 51-year-old woman diagnosed as having normal-tension glaucoma developed an acquired pit of the optic nerve. The optic disc was viewed by the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) before and after development of an acquired pit of the optic nerve. HRT parameters and cross-sectional images of the optic disc were compared. Maximum cup depth at the site of the acquired pit of the optic nerve increased after development of the acquired pit of the optic nerve (from 1.200 to 2.432 mm). The neuroretinal rim area and volume in the inferotemporal octant were reduced (rim area from 0.070 to 0.010 mm2, rim volume from 0.009 to 0.001 mm3). The morphologic changes in the optic disc were also detected topographically and reflectively.

  14. Agreement of glaucoma specialists and experienced optometrists in gonioscopy and optic disc evaluation

    PubMed Central

    Kumar, Addepalli U.; Jonnadula, Ganesh B.; Garudadri, Chandrasekhar; Rao, Harsha L.; Senthil, Sirisha; Papas, Eric B.; Sankaridurg, Padmaja; Khanna, Rohit C.

    2013-01-01

    Purpose To compare the diagnostic performance of glaucoma specialists and experienced optometrists in gonioscopy and optic disc assessment. Methods This study was done to validate the diagnostic performance of two experienced optometrists for using their skills of detecting glaucoma using gonioscopy and optic disc assessment in a major epidemiological study, the L V Prasad Eye Institute Glaucoma Epidemiology and Molecular Genetics Study (LVPEI-GLEAMS). Gonioscopic findings for 150 eyes were categorized as 0, 1 and 2 for open angle, primary angle closure suspect (PACS) and primary angle closure (PAC) respectively. Optic disc findings for 200 eyes were categorized as 0, 1 and 2 for normal, suspects and glaucomatous respectively. Weighted kappa (κ) and diagnostic accuracy parameters were calculated. Two optometrists (#1 and #2) participated in the study. Results Agreement between glaucoma specialists and optometrist for interpretation of gonioscopy to discriminate PACS and PAC from open angles and for interpretation of optic disc to discriminate glaucomatous and suspicious discs from normal, the kappa (κ) was 0.92 and 0.84 and 0.90 and 0.89 for optometrists #1 and #2 respectively. Sensitivities and specificities were above 90% for gonioscopy. Optic disc evaluation had specificities greater than 95% to discriminate normal from glaucomatous discs while the sensitivities were 83% and 93% for optometrists #1 and #2 respectively. Conclusion Agreement between optometrists and glaucoma specialists, in diagnostic performance of gonioscopy and optic assessment was excellent with high sensitivity and specificity. Hence, we conclude that the experienced optometrists can detect glaucoma accurately in the LVPEI-GLEAMS.

  15. Correlation between corneal thickness and optic disc morphology in normal tension glaucoma using modern technical analysis.

    PubMed

    Coman, Laurenţiu; Costescu, Monica; Alecu, Mihail; Coman, Oana Andreia

    2014-01-01

    The purpose of this study was to evaluate the relationship between central corneal thickness (CCT) and optic disc morphology in normal tension glaucoma (NTG). Patients with NTG underwent eye examination, optic disc imaging with Heildelberg Retina Tomograph II (HRT II) and ultrasound corneal pachymetry. The morphological parameters of the optic discs were used to classify the eyes into four groups: generalized enlargement (GE) type, myopic glaucomatous (MY) type, focal ischemic (FI) type and senile sclerotic (SS) type. A correlation between CCT and optic disc morphology obtained by HRT II was calculated. Multiple comparison and post hoc tests were performed in order to determine the significance of the differences between the four groups. The strongest correlation was between CCT and the parameters of optic disc imaging obtained at HRT II in the GE type of optic disc.

  16. Optical Disc Technology for Information Management.

    ERIC Educational Resources Information Center

    Brumm, Eugenia K.

    1991-01-01

    This summary of the literature on document image processing from 1988-90 focuses on WORM (write once read many) technology and on rewritable (i.e., erasable) optical discs, and excludes CD-ROM. Highlights include vendors and products, standards, comparisons of storage media, software, legal issues, records management, indexing, and computer…

  17. Plaque radiotherapy for choroidal melanoma encircling the optic disc (circumpapillary choroidal melanoma).

    PubMed

    Sagoo, Mandeep S; Shields, Carol L; Mashayekhi, Arman; Freire, Jorge; Emrich, Jacqueline; Reiff, Jay; Komarnicky, Lydia; Shields, Jerry A

    2007-09-01

    To report results of plaque radiotherapy for choroidal melanoma that completely encircles the optic disc (circumpapillary melanoma). Retrospective medical record review over a 31-year period of 37 consecutive patients. The main outcome measures were treatment complications, long-term visual acuity, enucleation, tumor recurrence, metastasis, and death. The median patient age at treatment was 69 years (range, 20-86 years). The presenting complaint was visual loss in 19 eyes (51%), photopsia in 5 (14%), and visual field loss in 3 (8%). All tumors touched and encircled the optic disc for 360 degrees . The quadrantic location of the main tumor epicenter was superior in 8 eyes (22%), nasal in 10 (27%), inferior in 9 (24%), and temporal in 10 (27%). The median tumor basal diameter was 11 mm (range, 4.8-20 mm) and median tumor thickness was 3.6 mm (range, 1.8-14.8 mm). The optic disc was obscured to some extent by overhanging tumor in 19 cases (52%). The most commonly used isotope for plaque radiotherapy was iodine 125 (n = 34 cases; 92%), and a notched plaque design was used in 34 cases (92%). Planned adjunctive treatment included transpupillary thermotherapy in 17 cases (49%) and argon laser photocoagulation in 6 of 35 cases (17%) with follow-up. Of the 28 eyes with more than 5 months' follow-up (mean, 52 months; median, 46 months; range, 5-234 months), treatment complications included nonproliferative and proliferative retinopathy in 11 (39%) and 7 eyes (25%); maculopathy in 7 (25%); papillopathy in 9 eyes (32%); neovascular glaucoma in 5 (18%); and vitreous hemorrhage in 13 (46%). Pars plana vitrectomy was required in only 2 of 13 eyes (15%) with persistent vitreous hemorrhage. Long-term visual acuity of 20/200 or worse was observed in 13 eyes (62%), and 12 eyes (57%) lost more than 5 Snellen visual acuity lines, excluding 7 cases (25%) in which enucleation was necessary. Recurrence was noted in 4 cases (14%), of which 3 were treated with enucleation and 1 with

  18. Topographic optic disc analysis by Heidelberg retinal tomography in ocular Behçet's disease

    PubMed Central

    Berker, Nilufer; Elgin, Ufuk; Ozdal, Pinar; Batman, Aygen; Soykan, Emel; Ozkan, Seyhan S

    2007-01-01

    Aim To compare the topographic characteristics of the optic discs in patients with severe and mild ocular Behçet's disease by using Heidelberg retinal tomographaphy (HRT). Methods This prospective study included 47 eyes of 47 patients with ocular BD who were being followed‐up at the Uveitis Clinic of the Ankara Ulucanlar Eye Research Hospital, Ankara, Turkey. The patients were divided into two groups. Group 1 consisted of 21 eyes with mild uveitis, and group 2 consisted of 26 eyes with severe uveitis. All patients underwent topographic optic disc analysis by HRT II, and the quantitative optic disc parameters of both groups were compared by non‐parametric Mann‐Whitney U test. Results The mean cup volume, rim volume, cup area, disc area and cup depth in group 1 were found to be statistically significantly greater than those in group 2 (p<0.0001, p = 0.03, p = 0.021, p = 0.01 and p = 0.017, respectively), while the difference between the mean cup‐to‐disc ratios in group 1 and group 2 were found to be statistically insignificant (p = 0.148). Conclusion A relationship was found between the severity of ocular BD and optic disc topography determined by HRT. In eyes with smaller optic discs, uveitis was observed to have a more severe course with more frequent relapses than those with larger discs. PMID:17475703

  19. Comparison of Automated Analysis of Cirrus HD-OCT™ Spectral Domain Optical Coherence Tomography with Stereo Photos of the Optic Disc

    PubMed Central

    Sharma, Ashish; Oakley, Jonathan D.; Schiffman, Joyce C.; Budenz, Donald L.; Anderson, Douglas R.

    2010-01-01

    OBJECTIVE To evaluate a new automated analysis of optic disc images obtained by spectral domain optical coherence tomography (SD-OCT). Areas of the optic disc, cup, and neural rim in SD-OCT images were compared with these areas from stereoscopic photographs, to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN Evaluation of diagnostic technology. PARTICIPANTS 119 healthy eyes, 23 eyes with glaucoma, and 7 suspect eyes METHODS Optic disc and cup margins were traced from stereoscopic photographs by three individuals independently. Optic disc margins and rim widths were determined automatically in SD-OCT. A subset of photographs was examined and traced a second time, and duplicate SD-OCT images were also analyzed. MAIN OUTCOME MEASUREMENTS Agreement among photograph readers, between duplicate readings, and between SD-OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square (RMS), and the standard deviation (SD) of the differences. RESULTS Optic disc areas tended to be slightly larger when judged in photographs than by SD-OCT, while cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between average photographic reading and SD-OCT, but only fair correlation of rim areas (0.4). The SD-OCT was highly reproducible (ICC of 0.96 to 0.99). Each reader was also consistent with himself on duplicate readings of 21 photographs (ICC 0.80 to 0.88 for rim area, 0.95 to 0.98 for all other measurements), but reproducibility was not as good as SD-OCT. Measurements derived from SD-OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS Designation of the cup and optic disc boundaries by an automated analysis of SD-OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of

  20. Persistent Asymmetric Optic Disc Swelling After Long-Duration Space Flight: Implications for Pathogenesis.

    PubMed

    Mader, Thomas H; Gibson, C Robert; Otto, Christian A; Sargsyan, Ashot E; Miller, Neil R; Subramanian, Prem S; Hart, Stephen F; Lipsky, William; Patel, Nimesh B; Lee, Andrew G

    2017-06-01

    Several ophthalmic findings including optic disc swelling, globe flattening and choroidal folds have been observed in astronauts following long-duration space flight. The authors now report asymmetric choroidal expansion, disc swelling and optic disc morphologic changes in a 45-year-old astronaut which occurred during long-duration space flight and persisted following his space mission. Case study of ocular findings in an astronaut documented during and after a long-duration space flight of approximately 6 months. Before, during and after his spaceflight, he underwent complete eye examination, including fundus photography, ultrasound, and optical coherence tomography. We documented asymmetric choroidal expansion inflight that largely resolved by 30 days postflight, asymmetric disc swelling observed inflight that persisted for over 180 days postflight, asymmetric optic disc morphologic changes documented inflight by OCT that persisted for 630 days postflight and asymmetric globe flattening that began inflight and continued 660 days postflight. Lumbar puncture opening pressures obtained at 7 and 365 days post-mission were 22 and 16 cm H20 respectively. The persistent asymmetric findings noted above, coupled with the lumbar puncture opening pressures, suggest that prolonged microgravity exposure may have produced asymmetric pressure changes within the perioptic subarachnoid space.

  1. Optical coherence tomography detects characteristic retinal nerve fiber layer thickness corresponding to band atrophy of the optic discs.

    PubMed

    Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira

    2004-12-01

    To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.

  2. Role of Retinal Nerve Fiber Layer Thickness and Optic Disk Measurement by OCT on Early Diagnosis of Glaucoma.

    PubMed

    Hua, Zanmei; Fang, Qiuyun; Sha, Xiangyin; Yang, Ruiming; Hong, Zuopeng

    2015-03-01

    Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography (OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters. A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer (RNFL) thickness and the optic disc tomography by spectral-domain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma (POAG). This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control (n = 51, 98 eyes), suspected glaucoma (n = 81, 146 eyes), and POAG groups (n = 55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness, disc area (DA), cup area (CA), rim area (RA), disc volume (DV), cup volume (CV), rim volume (RV), cup/disc area ratio (CA/DA), rim/disc area ratio (RA/DA), cup/disc volume ratio (CV/DV) and rim/disc volume ratio (RV/DV). Superior, nasal, and mean RNFL parameters, DA, CA,RA, DV, CV, CA/DA, RA/DA, CV/DV and RV/DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group, the maximum area under the ROC curve (AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA/DA (0.998), followed by CA/DA (0.997). The AROC of CA, RA, CV, and DV were all > 0.900. OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG.

  3. Joint optic disc and cup boundary extraction from monocular fundus images.

    PubMed

    Chakravarty, Arunava; Sivaswamy, Jayanthi

    2017-08-01

    Accurate segmentation of optic disc and cup from monocular color fundus images plays a significant role in the screening and diagnosis of glaucoma. Though optic cup is characterized by the drop in depth from the disc boundary, most existing methods segment the two structures separately and rely only on color and vessel kink based cues due to the lack of explicit depth information in color fundus images. We propose a novel boundary-based Conditional Random Field formulation that extracts both the optic disc and cup boundaries in a single optimization step. In addition to the color gradients, the proposed method explicitly models the depth which is estimated from the fundus image itself using a coupled, sparse dictionary trained on a set of image-depth map (derived from Optical Coherence Tomography) pairs. The estimated depth achieved a correlation coefficient of 0.80 with respect to the ground truth. The proposed segmentation method outperformed several state-of-the-art methods on five public datasets. The average dice coefficient was in the range of 0.87-0.97 for disc segmentation across three datasets and 0.83 for cup segmentation on the DRISHTI-GS1 test set. The method achieved a good glaucoma classification performance with an average AUC of 0.85 for five fold cross-validation on RIM-ONE v2. We propose a method to jointly segment the optic disc and cup boundaries by modeling the drop in depth between the two structures. Since our method requires a single fundus image per eye during testing it can be employed in the large-scale screening of glaucoma where expensive 3D imaging is unavailable. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. [Flicker comparison of optic disc photographs: sensitivity and specificity].

    PubMed

    Funk, Jens; Lagrèze, Wolf; Zeyen, Thierry

    2002-12-01

    Examination and documentation of the optic nerve head are essential in monitoring glaucoma patients. Even minor changes in optic nerve head morphology can be visualised using the so-called flicker test: Two optic nerve head photographs, taken at consecutive examinations, are superimposed by projection. When occluding the pictures in a rapid alternating fashion, changes in optic nerve head morphology appear as motion. In this study, we evaluated sensitivity and specificity of the flicker test. A set of 33 pairs of serial optic disc slides was used as gold standard. These 33 pairs had been classified earlier by 3 independent groups of experts. 23 had been classified as "no change over time", 10 had been classified as "change". All 33 pairs were now evaluated by flicker comparison in a masked fashion. Flicker comparison usually took 1 minute per pair of slides. Sensitivity was 90 %, specificity was 65 %. The sensitivity was reasonably high. The moderate specificity was due to some cases showing "change" with the flicker comparison which might have been overlooked by the expert groups. Flicker comparison is an easy, fast and reliable technique to evaluate pairs of consecutive optic disc photographs.

  5. Tracking dynamics of photoreceptor disc shedding with adaptive optics-optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Furu; Liu, Zhuolin; Kurokawa, Kazuhiro; Miller, Donald T.

    2017-02-01

    Absorption of light by photoreceptors initiates vision, but also leads to accumulation of toxic photo-oxidative compounds in the photoreceptor outer segment (OS). To prevent this buildup, small packets of OS discs are periodically pruned from the distal end of the OS, a process called disc shedding. Unfortunately dysfunction in any part of the shedding event can lead to photoreceptor and RPE dystrophy, and has been implicated in numerous retinal diseases, including age related macular degeneration and retinitis pigmentosa. While much is known about the complex molecular and signaling pathways that underpin shedding, all of these advancements have occurred in animal models using postmortem eyes. How these translate to the living retina and to humans remain major obstacles. To that end, we have recently discovered the optical signature of cone OS disc shedding in the living human retina, measured noninvasively using optical coherence tomography equipped with adaptive optics in conjunction with post processing methods to track and monitor individual cones in 4D. In this study, we improve on this method in several key areas: increasing image acquisition up to MHz A-scan rates, improving reliability to detect disc shedding events, establishing system precision, and developing cone tracking for use across the entire awake cycle. Thousands of cones were successfully imaged and tracked over the 17 hour period in two healthy subjects. Shedding events were detected in 79.5% and 77.4% of the tracked cones. Similar to previous animal studies, shedding prevalence exhibited a diurnal rhythm. But we were surprised to find that for these two subjects shedding occurred across the entire day with broad, elevated frequency in the morning and decreasing frequency as the day progressed. Consistent with this, traces of the average cone OS length revealed shedding dominated in the morning and afternoon and renewal in the evening.

  6. Estimating normative limits of Heidelberg Retina Tomograph optic disc rim area with quantile regression.

    PubMed

    Artes, Paul H; Crabb, David P

    2010-01-01

    To investigate why the specificity of the Moorfields Regression Analysis (MRA) of the Heidelberg Retina Tomograph (HRT) varies with disc size, and to derive accurate normative limits for neuroretinal rim area to address this problem. Two datasets from healthy subjects (Manchester, UK, n = 88; Halifax, Nova Scotia, Canada, n = 75) were used to investigate the physiological relationship between the optic disc and neuroretinal rim area. Normative limits for rim area were derived by quantile regression (QR) and compared with those of the MRA (derived by linear regression). Logistic regression analyses were performed to quantify the association between disc size and positive classifications with the MRA, as well as with the QR-derived normative limits. In both datasets, the specificity of the MRA depended on optic disc size. The odds of observing a borderline or outside-normal-limits classification increased by approximately 10% for each 0.1 mm(2) increase in disc area (P < 0.1). The lower specificity of the MRA with large optic discs could be explained by the failure of linear regression to model the extremes of the rim area distribution (observations far from the mean). In comparison, the normative limits predicted by QR were larger for smaller discs (less specific, more sensitive), and smaller for larger discs, such that false-positive rates became independent of optic disc size. Normative limits derived by quantile regression appear to remove the size-dependence of specificity with the MRA. Because quantile regression does not rely on the restrictive assumptions of standard linear regression, it may be a more appropriate method for establishing normative limits in other clinical applications where the underlying distributions are nonnormal or have nonconstant variance.

  7. Micropulse laser for persistent optic disc pit maculopathy. A case report.

    PubMed

    Valdés-Lara, Carlos Andrés; Crim, Nicolás; García-Aguirre, Gerardo; Lule, Ismael Ávila; Morales-Cantón, Virgilio

    2018-06-01

    Optic disc pits (ODP) are rare and congenital anomalies of the optic disc, sometimes remaining asymptomatic. However, serous macular detachment or optic disc maculopathy is the most common complication, causing significant visual deterioration, without a current consensus about treatment. We describe a case of ODP maculopathy that was treated successfully with micropulse laser. A patient with ODP maculopathy remained with macular serous detachment after nine months of follow up after pars plana vitrectomy. Subthreshold micropulse laser was used to treat macular serous detachment, achieving a significant improvement in central macular thickness after one session. Subthreshold micropulse laser is designed to stimulate the retinal pigment epithelium without damage to the photoreceptors, resulting in absorption of subretinal and intraretinal fluid. Macular serous detachment in patients with ODP requires a prompt diagnosis and treatment to avoid damage to photoreceptors. Subthreshold micropulse laser is a potential treatment for eyes with ODP and macular serous detachment complication.

  8. Quantitative comparison of disc rim color in optic nerve atrophy of compressive optic neuropathy and glaucomatous optic neuropathy.

    PubMed

    Nakano, Eri; Hata, Masayuki; Oishi, Akio; Miyamoto, Kazuaki; Uji, Akihito; Fujimoto, Masahiro; Miyata, Manabu; Yoshimura, Nagahisa

    2016-08-01

    The purpose was to investigate an objective and quantitative method to estimate the redness of the optic disc neuroretinal rim, and to determine the usefulness of this method to differentiate compressive optic neuropathy (CON) from glaucomatous optic neuropathy (GON). In our study there were 126 eyes: 40 with CON, 40 with normal tension glaucoma (NTG), and 46 normal eyes (NOR). Digital color fundus photographs were assessed for the redness of disc rim color using ImageJ software. We separately measured the intensity of red, green, and blue pixels from RGB images. Three disc color indices (DCIs), which indicate the redness intensity, were calculated through existing formulas. All three DCIs of CON were significantly smaller than those of NOR (P < 0.001). In addition, when compared with NTG, DCIs were also significantly smaller in CON (P < 0.05). A comparison of mild CON and mild NTG (mean deviation (MD) > -6 dB), in which the extent of retinal nerve fiber layer thinning is comparable, the DCIs of mild CON were significantly smaller than those of mild NTG (P < 0.05). In contrast, DCIs did not differ between moderate-to-severe stages of CON and NTG (MD ≤ -6 dB), though the retinal nerve fibers of CON were more severely damaged than those of NTG. To differentiate between mild CON and mild NTG, all AUROCs for the three DCIs were above 0.700. A quantitative and objective assessment of optic disc color was useful in differentiating early-stage CON from GON and NOR.

  9. High-density near-field optical disc recording using phase change media and polycarbonate substrate

    NASA Astrophysics Data System (ADS)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2004-09-01

    We developed a high density near field optical recording disc system with a solid immersion lens and two laser sources. In order to realize the near field optical recording, we used a phase change recording media and a molded polycarbonate substrate. The near field optical pick-up consists of a solid immersion lens with numerical aperture of 1.84. The clear eye pattern of 90.2 GB capacity (160nm track pitch and 62 nm per bit) was observed. The jitter using a limit equalizer was 10.0 % without cross-talk. The bit error rate using an adaptive PRML with 8 taps was 3.7e-6 without cross-talk. We confirmed that the near field optical disc system is a promising technology for a next generation high density optical disc system.

  10. Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study.

    PubMed

    Savini, G; Zanini, M; Carelli, V; Sadun, A A; Ross-Cisneros, F N; Barboni, P

    2005-04-01

    To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4 acquisition protocol). ONH analysis was performed by means of six radial scans centred on the optic disc (Stratus OCT, Fast Optic Disc acquisition protocol). The mean RNFL values were correlated with the data obtained by ONH analysis. The superior, nasal, and inferior quadrant RNFL thickness showed a significant correlation with the optic disc area (R = 0.3822, p = 0.0043), (R = 0.3024, p = 0.026), (R = 0.4048, p = 0.0024) and the horizontal disc diameter (R = 0.2971, p = 0.0291), (R = 0.2752, p = 0.044), (R = 0.3970, p = 0.003). The superior and inferior quadrant RNFL thickness was also positively correlated with the vertical disc diameter (R = 0.3774, p = 0.0049), (R = 0.2793, p = 0.0408). A significant correlation was observed between the 360 degrees average RNFL thickness and the optic disc area and the vertical and horizontal disc diameters of the ONH (R = 0.4985, p = 0.0001), (R = 0.4454, p = 0.0007), (R = 0.4301, p = 0.0012). RNFL thickness measurements obtained by Stratus OCT increased significantly with an increase in optic disc size. It is not clear if eyes with large ONHs show a thicker RNFL as a result of an increased amount of nerve fibres or to the shorter distance between the circular scan and the optic disc edge.

  11. Interlayer Crosstalk Reduction by Controlling Backward Reflectivity in Multilayer Optical Discs

    NASA Astrophysics Data System (ADS)

    Ushiyama, Junko; Miyauchi, Yasushi; Shintani, Toshimichi; Sugiyama, Toshinori; Miyamoto, Harukazu; Kurokawa, Takahiro

    2008-05-01

    A method is proposed to reduce interlayer crosstalk in multilayer optical discs by controlling backward reflectivity of information layers, which can lead to wider tolerances of disc fabrication accuracy. Reduction of the backward reflectivity reduces the signal from the ghost spot even if thicknesses of spacer layers are equal. Experimental results showed that the ratio of the signals obtained by the readout spot and the ghost spot is less by about one order for a disc with controlled backward reflectivity than for a conventional disc. A rough estimate of the crosstalk caused by the ghost spot agrees qualitatively with the experimental results.

  12. Stereochronoscopy of the optic disc with stereoscopic cameras.

    PubMed

    Schirmer, K E; Kratky, V

    1980-09-01

    Goldmann's chronoscopy, a form of time-based photogrammetry of the optic disc, can be accomplished by repeated simultaneous stereophotography. The variations in centration and image orientation are nulled by azimuthal rotation and fusion of two pairs of stereophotographs taken at separate times.

  13. Constraints on the temperature inhomogeneity in quasar accretion discs from the ultraviolet-optical spectral variability

    NASA Astrophysics Data System (ADS)

    Kokubo, Mitsuru

    2015-05-01

    The physical mechanisms of the quasar ultraviolet (UV)-optical variability are not well understood despite the long history of observations. Recently, Dexter & Agol presented a model of quasar UV-optical variability, which assumes large local temperature fluctuations in the quasar accretion discs. This inhomogeneous accretion disc model is claimed to describe not only the single-band variability amplitude, but also microlensing size constraints and the quasar composite spectral shape. In this work, we examine the validity of the inhomogeneous accretion disc model in the light of quasar UV-optical spectral variability by using five-band multi-epoch light curves for nearly 9 000 quasars in the Sloan Digital Sky Survey (SDSS) Stripe 82 region. By comparing the values of the intrinsic scatter σint of the two-band magnitude-magnitude plots for the SDSS quasar light curves and for the simulated light curves, we show that Dexter & Agol's inhomogeneous accretion disc model cannot explain the tight inter-band correlation often observed in the SDSS quasar light curves. This result leads us to conclude that the local temperature fluctuations in the accretion discs are not the main driver of the several years' UV-optical variability of quasars, and consequently, that the assumption that the quasar accretion discs have large localized temperature fluctuations is not preferred from the viewpoint of the UV-optical spectral variability.

  14. Automated analysis of heidelberg retina tomograph optic disc images by glaucoma probability score.

    PubMed

    Coops, Annemiek; Henson, David Barry; Kwartz, Anna J; Artes, Paul Habib

    2006-12-01

    To compare the diagnostic performance of the Heidelberg Retinal Tomograph's (HRT; Heidelberg Engineering GmbH, Dossenheim, Germany) glaucoma probability score (GPS), an automated, contour line-independent method of optic disc analysis with that of the Moorfields regression analysis (MRA). HRT images were obtained from one eye of 121 patients with glaucoma (median age, 70.2 years; median mean deviation [MD], -3.6 dB, range, +2.0 to -9.9 dB) and 95 healthy control subjects (median age, 59.7 years; median MD -0.1 dB, range +2.5 to -3.7). The diagnostic performances of GPS and MRA were evaluated by including borderline classifications, either as test negatives (most specific criteria) or as test positives (least specific criteria). Agreement between global and sectoral data of both analyses was established. Logistic regression analyses were performed to evaluate the effect of covariates such as optic disc size and age on the classification outcomes of both the GPS and the MRA. In 8 (7%) patients with glaucoma and 10 (11%) control subjects, the GPS failed to provide a complete global and sectoral optic disc classification. Although we could not identify a single distinct cause of this failure in the glaucoma group, failures in the control subjects occurred most often (7/10) with small and crowded optic discs. In subjects who were successfully classified at least globally by the GPS (117 patients with glaucoma, 88 control subjects), the diagnostic performances of GPS and MRA were similar (areas under the receiver operating characteristic [ROC] curve of 0.78 and 0.77, respectively; P > 0.1). With the GPS, sensitivity and specificity were 59% and 91% (most specific criteria) and 78% and 63% (least specific criteria), respectively. Combining GPS and MRA did not increase diagnostic performance significantly (ROC area of combined classifiers, 0.81). Both GPS and MRA were affected by disc size. In patients with glaucoma as well as healthy control subjects, the odds of a

  15. Effect of systemic nitric oxide synthase inhibition on optic disc oxygen partial pressure in normoxia and in hypercapnia.

    PubMed

    Petropoulos, Ioannis K; Pournaras, Jean-Antoine C; Stangos, Alexandros N; Pournaras, Constantin J

    2009-01-01

    To investigate the effect of systemic nitric oxide synthase (NOS) inhibition on optic disc oxygen partial pressure (PO(2)) in normoxia and hypercapnia. Intervascular optic disc PO(2) was measured in 12 anesthetized minipigs by using oxygen-sensitive microelectrodes placed <50 microm from the optic disc. PO(2) was measured continuously during 10 minutes under normoxia, hyperoxia (100% O(2)), carbogen breathing (95% O(2), 5% CO(2)), and hypercapnia (increased inhaled CO(2)). Measurements were repeated after intravenous injection of N(omega)-nitro-L-arginine methyl ester (L-NAME) 100 mg/kg. Intravenous L-arginine 100 mg/kg was subsequently given to three animals. Before L-NAME injection, an increase was observed in optic disc PO(2) during hypercapnia (DeltaPO(2) = 3.2 +/- 1.7 mm Hg; 18%; P = 0.001) and carbogen breathing (DeltaPO(2) = 12.8 +/- 5.1 mm Hg; 69%; P < 0.001). Optic disc PO(2) in normoxia remained stable for 30 minutes after L-NAME injection (4% decrease from baseline; P > 0.1), despite a 21% increase of mean arterial pressure. Optic disc PO(2) increase under hypercapnia was blunted after L-NAME injection (DeltaPO(2) = 0.6 +/- 1.1 mm Hg; 3%; P > 0.1), and this effect was reversible by L-arginine. Moreover, L-NAME reduced the response to carbogen by 29% (DeltaPO(2) = 9.1 +/- 4.4 mm Hg; 49%; P = 0.01 versus before L-NAME). The response to hyperoxia was not affected. Whereas systemic NOS inhibition did not affect optic disc PO(2) in normoxia, a blunting effect was noted on the CO(2)-induced optic disc PO(2) increase. Nitric oxide appears to mediate the hypercapnic optic disc PO(2) increase.

  16. Disc origin of broad optical emission lines of the TDE candidate PTF09djl

    NASA Astrophysics Data System (ADS)

    Liu, F. K.; Zhou, Z. Q.; Cao, R.; Ho, L. C.; Komossa, S.

    2017-11-01

    An otherwise dormant supermassive black hole (SMBH) in a galactic nucleus flares up when it tidally disrupts a star passing by. Most of the tidal disruption events (TDEs) and candidates discovered in the optical/UV have broad optical emission lines with complex and diverse profiles of puzzling origin. In this Letter, we show that the double-peaked broad H α line of the TDE candidate PTF09djl can be well modelled with a relativistic elliptical accretion disc and the peculiar substructures with one peak at the line rest wavelength and the other redshifted to about 3.5 × 104 km s-1 are mainly due to the orbital motion of the emitting matter within the disc plane of large inclination 88° and pericentre orientation nearly vertical to the observer. The accretion disc has an extreme eccentricity 0.966 and semimajor axis of 340 BH Schwarzschild radii. The viewing angle effects of large disc inclination lead to significant attenuation of He emission lines originally produced at large electron scattering optical depth and to the absence/weakness of He emission lines in the spectra of PTF09djl. Our results suggest that the diversities of line intensity ratios among the line species in optical TDEs are probably due to the differences of disc inclinations.

  17. Peripapillary choroidal thickness in healthy controls and patients with focal, diffuse, and sclerotic glaucomatous optic disc damage.

    PubMed

    Roberts, Kenneth F; Artes, Paul H; O'Leary, Neil; Reis, Alexandre S C; Sharpe, Glen P; Hutchison, Donna M; Chauhan, Balwantray C; Nicolela, Marcelo T

    2012-08-01

    To examine peripapillary choroidal thickness in healthy controls and in patients with glaucoma who have focal, diffuse, and sclerotic optic disc damage. Healthy controls (n=92) and patients with glaucoma who have focal (n=34), diffuse (n=35), and sclerotic (n=34) optic disc damage were imaged with spectral-domain optical coherence tomography (12° circular scan protocol centered on optic nerve head). Peripapillary choroidal thickness was measured as the distance between the automatically segmented retinal pigment epithelium/Bruch's membrane and the manually outlined interface between the posterior choroid and the anterior border of the sclera in eyes in which the anterior scleral border was visible over more than 85% of the scan circumference. The anterior scleral border was visible in 76 controls (83%) and 89 patients (86%). Peripapillary choroidal thickness in healthy controls decreased linearly with age (-11 μm/decade; P.001; r2=0.16), with a predicted value of 137 μm at age 70 years (95% prediction interval, 62-212 μm). While this value was similar in patients with focal and diffuse optic disc damage (126 and 130 μm, respectively; P=.22 compared with controls), it was approximately 30% lower in patients with sclerotic optic disc damage (96 μm; P.001 compared with controls). The peripapillary choroid of patients with glaucoma who have sclerotic optic disc damage was approximately 25% to 30% thinner compared with that in patients with focal and diffuse optic disc damage and with that in healthy controls. The role of the choroid in the pathophysiology of sclerotic glaucomatous optic disc damage needs further investigation.

  18. Optic disc segmentation for glaucoma screening system using fundus images.

    PubMed

    Almazroa, Ahmed; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-01-01

    Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head pathologies such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of optic nerve head abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique was applied. As well an important contribution was to involve the variations in opinions among the ophthalmologists in detecting the disc boundaries and diagnosing the glaucoma. Most of the previous studies were trained and tested based on only one opinion, which can be assumed to be biased for the ophthalmologist. In addition, the accuracy was calculated based on the number of images that coincided with the ophthalmologists' agreed-upon images, and not only on the overlapping images as in previous studies. The ultimate goal of this project is to develop an automated image processing system for glaucoma screening. The disc algorithm is evaluated using a new retinal fundus image dataset called RIGA (retinal images for glaucoma analysis). In the case of low-quality images, a double level set was applied, in which the first level set was considered to be localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as the agreement among the manual markings of six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid was 83.9%, and the best agreement was observed between the results of the algorithm and manual markings in 379 images.

  19. Three-dimensional spectral domain optical coherence tomography in X linked foveal retinoschisis

    PubMed Central

    Saxena, Sandeep; Manisha; Meyer, Carsten H

    2013-01-01

    Spectral domain optical coherence tomography (SD-OCT) was performed in two cases of bilateral X linked foveal retinoschisis of different age groups. On fundus examination spoke wheel and honeycomb pattern of cysts were observed along with retinal nerve fibre layer (RNFL) defects. On SD-OCT, schisis was observed in the outer plexiform layer. External limiting membrane disruption was observed in the subfoveal area, along with disruption of outer nuclear layer (ONL) and inner–outer segment junction. Elevation of ONL due to tractional pull of central palisade was a novel observation. Retinoschisis extended beyond the optic disc up to the nasal region. Extracted RNFL tomogram presented an unprecedented visualisation of schisis along 360° of the optic disc. Tractional elevation in the foveal area and schisis involving nasal region, not observed upon clinical examination, was highlighted on SD-OCT. This investigative modality is an important adjunct in the assessment of foveal retinoschisis. PMID:23563673

  20. Optic disc, foveal, and extrafoveal damage due to surgical separation of the vitreous.

    PubMed

    Russell, S R; Hageman, G S

    2001-11-01

    To evaluate the morphologic outcomes resulting from surgical vitreoretinal separation in young adult primates. Vitrectomy and mechanical separation of the vitreous from the internal limiting lamina (ILL) of the posterior retina and surface of the optic disc were performed on 25 young adult cynomolgus monkey eyes in vivo. Lectin histochemical studies were used to evaluate the vitreoretinal interface. Morphologic outcomes were tabulated. In 11 of 25 eye regions, residual vitreous remained attached to the ILL in some of the regions. Localized ILL breaks or separation of the ILL from the neural retina was noted in 9 eyes. Retinal tissue loss, including avulsion of the ganglion cell, inner plexiform, or inner nuclear layers, was observed in 7 eyes. Avulsion of axon bundles in the optic disc was noted in 9 eyes. Significantly, partial- or full-thickness foveal tears were noted in 11 eyes. Based on the surgeons' intraoperative observations, small superficial optic disc or retinal hemorrhages were observed in 3 of 25 eyes. None of the eyes on which a vitrectomy alone was performed showed ILL damage, or retinal or optic disc tissue loss. Damage may occur to the optic disc, fovea, and extrafoveal retina as a result of surgical separation of the vitreous from the retina in young adult primates. These data support the contention that surgically induced damage at the level of the vitreoretinal interface may help explain the visual field defects noted after surgery to close full-thickness macular holes. These data also support the need for developing additional modalities to assist in vitreous separation, thereby reducing the risk of traumatic complications associated with purely mechanical procedures.

  1. Influence of optic disc leakage on objective optic nerve head assessment in patients with uveitis.

    PubMed

    Heinz, Carsten; Kogelboom, Katy; Heiligenhaus, Arnd

    2016-02-01

    Secondary glaucoma is a common complication in patients with uveitis. Heidelberg Retina Tomography (HRT) and retinal nerve fiber layer (RNFL) thickness on optical coherence tomography (OCT) are widely used for examining optic nerve head changes. We evaluated these parameters in patients with uveitis and secondary glaucoma and with inflammatory papillary leakage on fluorescein angiography. Prospective single-center analysis of patients with uveitis, evaluating the impact of optic disc leakage on objective optic disc imaging parameters. Overall, 96 eyes of 59 patients were included. Papillary leakage was found in 42 eyes (43.8 %), and secondary glaucoma was found in 41 eyes (42.7 %). Glaucoma and papillary leakage were present in 12 (29 %) eyes with leakage and in 29 (54 %) eyes without leakage (p = 0.023). Neuroretinal rim area (p = 0.004), rim volume on HRT (p = 0.004), and RNFL thickness on OCT (p = 0.0008) were significantly increased in eyes with papillary leakage, while RNFL on HRT was unchanged (p = 0.255). When only eyes with normal IOP were examined, all objective parameters on OCT and HRT were significantly increased, whereas in eyes with secondary glaucoma, there was only a trend in the same direction, which did not reach significance. A comparison of eyes with secondary glaucoma and optic disc leakage to normal eyes with no glaucoma or leakage revealed no difference in any of the parameters. The objective parameters of optic nerve head imaging tools are significantly influenced by papillary leakage. In patients with secondary glaucoma and papillary leakage, these techniques are unable to detect and monitor glaucomatous damage.

  2. Holographic optical disc

    NASA Astrophysics Data System (ADS)

    Zhou, Gan; An, Xin; Pu, Allen; Psaltis, Demetri; Mok, Fai H.

    1999-11-01

    The holographic disc is a high capacity, disk-based data storage device that can provide the performance for next generation mass data storage needs. With a projected capacity approaching 1 terabit on a single 12 cm platter, the holographic disc has the potential to become a highly efficient storage hardware for data warehousing applications. The high readout rate of holographic disc makes it especially suitable for generating multiple, high bandwidth data streams such as required for network server computers. Multimedia applications such as interactive video and HDTV can also potentially benefit from the high capacity and fast data access of holographic memory.

  3. Longitudinal changes in the visual field and optic disc in glaucoma.

    PubMed

    Artes, Paul H; Chauhan, Balwantray C

    2005-05-01

    The nature and mode of functional and structural progression in open-angle glaucoma is a subject of considerable debate in the literature. While there is a traditionally held viewpoint that optic disc and/or nerve fibre layer changes precede visual field changes, there is surprisingly little published evidence from well-controlled prospective studies in this area, specifically with modern perimetric and imaging techniques. In this paper, we report on clinical data from both glaucoma patients and normal controls collected prospectively over several years, to address the relationship between visual field and optic disc changes in glaucoma using standard automated perimetry (SAP), high-pass resolution perimetry (HRP) and confocal scanning laser tomography (CSLT). We use several methods of analysis of longitudinal data and describe a new technique called "evidence of change" analysis which facilitates comparison between different tests. We demonstrate that current clinical indicators of visual function (SAP and HRP) and measures of optic disc structure (CSLT) provide largely independent measures of progression. We discuss the reasons for these findings as well as several methodological issues that pose challenges to elucidating the true structure-function relationship in glaucoma.

  4. Retinitis pigmentosa inversa with unilateral high myopia with fellow eye optic disc pitting.

    PubMed

    Sheth, Saumil; Rush, Ryan; Narayanan, Raja

    2011-01-01

    To report a possible rare association of bilateral retinitis pigmentosa inversa (RPI) with unilateral high myopia with fellow eye optic disc pitting. A 55-year-old man with a history of reduced vision in the right eye since childhood presented with gradually decreasing vision in the left eye. On examination, a -23.00 diopter refractive error and diffuse chorioretinal atrophy consistent with pathologic myopia was found in the right eye. An optic disc pit with posterior pole pigmentary alterations thought to be consequent to a previous neurosensory detachment was found in the left eye. Though the retinal arteriolar attenuation seen in both eyes with an inconsistent history of night blindness since childhood pointed towards the possibility of a concurrently existing rod or rod-cone dystrophy, the posterior pole pigmentary alterations characteristic of RPI were clearly masked by the above pathologies. Optical coherence tomography demonstrated prominent foveal atrophy and an optic disc pit in the left eye. Electroretinography (ERG) demonstrated moderately attenuated amplitudes with prolonged implicit times of rod and cone responses bilaterally. The patient was diagnosed with bilateral RPI and anisometropic amblyopia in the right eye. This report documents a unique constellation of findings which include bilateral RPI and unilateral high myopia with an optic disc pit in the fellow eye. An ERG confirmation of a dystrophic etiology should be sought in suspicious cases, especially when findings are masked by the concurrent presence of other pathologies.

  5. A new approach to optic disc detection in human retinal images using the firefly algorithm.

    PubMed

    Rahebi, Javad; Hardalaç, Fırat

    2016-03-01

    There are various methods and algorithms to detect the optic discs in retinal images. In recent years, much attention has been given to the utilization of the intelligent algorithms. In this paper, we present a new automated method of optic disc detection in human retinal images using the firefly algorithm. The firefly intelligent algorithm is an emerging intelligent algorithm that was inspired by the social behavior of fireflies. The population in this algorithm includes the fireflies, each of which has a specific rate of lighting or fitness. In this method, the insects are compared two by two, and the less attractive insects can be observed to move toward the more attractive insects. Finally, one of the insects is selected as the most attractive, and this insect presents the optimum response to the problem in question. Here, we used the light intensity of the pixels of the retinal image pixels instead of firefly lightings. The movement of these insects due to local fluctuations produces different light intensity values in the images. Because the optic disc is the brightest area in the retinal images, all of the insects move toward brightest area and thus specify the location of the optic disc in the image. The results of implementation show that proposed algorithm could acquire an accuracy rate of 100 % in DRIVE dataset, 95 % in STARE dataset, and 94.38 % in DiaRetDB1 dataset. The results of implementation reveal high capability and accuracy of proposed algorithm in the detection of the optic disc from retinal images. Also, recorded required time for the detection of the optic disc in these images is 2.13 s for DRIVE dataset, 2.81 s for STARE dataset, and 3.52 s for DiaRetDB1 dataset accordingly. These time values are average value.

  6. Comparison of optic disc topography in non-glaucomatous eyes of children with juvenile diabetes mellitus and normal children.

    PubMed

    Elgin, Ufuk; Cankaya, Bülent; Simsek, Tulay; Batman, Aygen

    2010-01-01

    To compare the optic disc topography parameters of children with juvenile diabetes mellitus and normal children using the Heidelberg Retinal Tomograph (HRT III) (Heidelberg Engineering, Heidelberg, Germany). The topographic optic disc parameters (cup volume, cup area, rim volume, rim area, disc area, mean cup-to-disc ratio, and mean cup depth) of 28 non-glaucomatous eyes of 28 children with type 1 diabetes mellitus and 28 eyes of 28 age-matched healthy children were compared using the nonparametric Mann-Whitney U test. No statistically significant differences were found between cup volume (P = .782), cup area (P = .878), rim volume (P = .853), disc area (P = .452), mean cup-to-disc ratio (P = .852), and mean cup depth (P = .711) of eyes of cases with diabetes mellitus and normal subjects. This result suggests that non-glaucomatous eyes of children with type 1 diabetes mellitus and healthy subjects have similar topographic optic disc characteristics. Copyright 2010, SLACK Incorporated.

  7. Optical properties of nasal septum cartilage

    NASA Astrophysics Data System (ADS)

    Bagratashvili, Nodar V.; Sviridov, Alexander P.; Sobol, Emil N.; Kitai, Moishe S.

    1998-05-01

    Optical parameters (scattering coefficient s, absorption coefficient k and scattering anisotropy coefficient g) of hyaline cartilage were studied for the first time. Optical properties of human and pig nasal septum cartilage, and of bovine ear cartilage were examined using a spectrophotometer with an integrating sphere, and an Optical Multi-Channel Analyser. We measured total transmission Tt, total reflection Rt, and on-axis transmission Ta for light propagating through cartilage sample, over the visible spectral range (14000 - 28000 cm-1). It is shown that transmission and reflection spectra of human, pig and bovine cartilage are rather similar. It allows us to conclude that the pig cartilage can be used for in-vivo studies instead of human cartilage. The data obtained were treated by means of the one-dimensional diffusion approximation solution of the optical transport equation. We have found scattering coefficient s, absorption coefficient k and scattering anisotropy coefficient g by the iterative comparison of measured and calculated Tt, Rt and Ta values for human and pig cartilage. We found, in particular, that for 500 nm irradiation s equals 37,6 plus or minus 3.5 cm-1, g equals 0,56 plus or minus 0.05, k approximately equals 0,5 plus or minus 0.3 cm-1. The above data were used in Monte Carlo simulation for spatial intensity profile of light scattered by a cartilage sample. The computed profile was very similar to the profile measured using an Optical Multi-Channel Analyzer (OMA).

  8. Resolution of recalcitrant uveitic optic disc edema following administration of methotrexate: two case reports.

    PubMed

    Woo, Se Joon; Kim, Mi Jeung; Park, Kyu Hyung; Lee, Yun Jong; Hwang, Jeong-Min

    2012-02-01

    A 13-year-old male and a 15-year-old female presented with optic disc edema associated with chronic recurrent uveitis. While the ocular inflammation responded to high doses of oral prednisolone, the disc edema showed little improvement. After oral administration of methotrexate, the disc edema and ocular inflammation were resolved, and the dose of oral corticosteroid could be reduced.

  9. Resolution of Recalcitrant Uveitic Optic Disc Edema Following Administration of Methotrexate: Two Case Reports

    PubMed Central

    Kim, Mi Jeung; Park, Kyu Hyung; Lee, Yun Jong; Hwang, Jeong-Min

    2012-01-01

    A 13-year-old male and a 15-year-old female presented with optic disc edema associated with chronic recurrent uveitis. While the ocular inflammation responded to high doses of oral prednisolone, the disc edema showed little improvement. After oral administration of methotrexate, the disc edema and ocular inflammation were resolved, and the dose of oral corticosteroid could be reduced. PMID:22323889

  10. Microstructure of the optic disc pit in open-angle glaucoma.

    PubMed

    Choi, Yun Jeong; Lee, Eun Ji; Kim, Bo Hyuk; Kim, Tae-Woo

    2014-11-01

    To investigate the structural and clinical characteristics of the optic disc pit (ODP) in primary open-angle glaucoma (POAG) via enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). Prospective, observational case series. Seventy POAG eyes clinically diagnosed with an ODP via stereo disc photography. Optic discs were scanned using EDI SD-OCT. Serial horizontal and vertical B-scan images covering the optic discs were obtained from each eye. The structural characteristics of the ODP were investigated via 3-dimensional images constructed from the serial B-scans, focusing on the presence of alterations in the contour of the lamina cribrosa (LC) or prelaminar tissue (PLT), in conjunction with associated clinical characteristics. The structural characteristics of the ODP and associated clinical characteristics. In the EDI SD-OCT images, the ODP was viewed as an isolated alteration of the LC (n = 14, 20.0%) or PLT (n = 16, 22.9%) or an alteration of both the LC and PLT (n = 40, 57.1%). Alterations of the LC were located at the mid-periphery near the LC insertion (n = 17) or far periphery adjacent to the LC insertion (n = 37), and the depth of alteration was deep (n = 23), involving nearly full-thickness LC, or shallow (n = 31), with partially visible LC at the base. Fifty-four eyes (77.1%) exhibited parafoveal visual field (VF) defect within 10 degrees of fixation, and in 98.1% of these eyes (53/54) it was spatially associated with the location of ODP. The parafoveal VF defect was more prevalent in eyes with LC alteration than those without (83.3% vs. 56.2%, P = 0.023) and in eyes with deep LC defect than those with shallow defect (95.7% vs. 74.2%, P = 0.036). Disc hemorrhage (32.4% vs. 0.0%, P = 0.008) and peripapillary retinoschisis (18.9 vs. 0.0%, P = 0.055) were more strongly associated with LC alterations located at the far periphery than at the mid-periphery. Enhanced depth imaging SD-OCT facilitated visualization of the varied

  11. Glaucoma diagnostic accuracy of optical coherence tomography parameters in early glaucoma with different types of optic disc damage.

    PubMed

    Shin, Hye-Young; Park, Hae-Young Lopilly; Jung, Younhea; Choi, Jin-A; Park, Chan Kee

    2014-10-01

    To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Retrospective, observational study. A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic

  12. Intracranial pressure-induced optic nerve sheath response as a predictive biomarker for optic disc edema in astronauts.

    PubMed

    Wostyn, Peter; De Deyn, Peter Paul

    2017-11-01

    A significant proportion of the astronauts who spend extended periods in microgravity develop ophthalmic abnormalities. Understanding this syndrome, called visual impairment and intracranial pressure (VIIP), has become a high priority for National Aeronautics and Space Administration, especially in view of future long-duration missions (e.g., Mars missions). Moreover, to ensure selection of astronaut candidates who will be able to complete long-duration missions with low risk of the VIIP syndrome, it is imperative to identify biomarkers for VIIP risk prediction. Here, we hypothesize that the optic nerve sheath response to alterations in intracranial pressure may be a potential predictive biomarker for optic disc edema in astronauts. If confirmed, this biomarker could be used for preflight identification of astronauts at risk for developing VIIP-associated optic disc edema.

  13. Preliminary optical coherence tomography investigation of the temporo-mandibular joint disc

    NASA Astrophysics Data System (ADS)

    Mărcăuteanu, Corina; Demjan, Enikö; Sinescu, Cosmin; Negrutiu, Meda; Motoc, Adrian; Lighezan, Rodica; Vasile, Liliana; Hughes, Mike; Bradu, Adrian; Dobre, George; Podoleanu, Adrian G.

    2010-02-01

    Aim and objectives. The morphology and position of the temporo-mandibular disc are key issues in the diagnosis and treatment of arthrogenous temporo-mandibular disorders. Magnetic resonance imaging and arthroscopy are used today to identify: flattening of the pars posterior of the disc, perforation and/or adhesions in the pars intermedia of the disc and disc displacements. The present study proposes the investigation of the temporo-mandibular joint disc by optical coherence tomography (OCT). Material and methods. 8 human temporo-mandibular joint discs were harvested from dead subjects, under 40 year of age, and conserved in formalin. They had a normal morphology, with a thicker pars posterior (2,6 mm on the average) and a thinner pars intermedia (1mm on the average). We investigated the disc samples using two different OCT systems: an en-face OCT (time domain (TD)-OCT) system, working at 1300 nm (C-scan and B-scan mode) and a spectral OCT system (a Fourier domain (FD)-OCT) system , working at 840 nm (B-scan mode). Results. The OCT investigation of the temporo-mandibular joint discs revealed a homogeneous microstructure. The longer wavelength of the TD-OCT offers a higher penetration depth (2,5 mm in air), which is important for the analysis of the pars posterior, while the FD-OCT is much faster. Conclusions: OCT is a promising imaging method for the microstructural characterization of the temporo-mandibular disc.

  14. Automated boundary detection of the optic disc and layer segmentation of the peripapillary retina in volumetric structural and angiographic optical coherence tomography.

    PubMed

    Zang, Pengxiao; Gao, Simon S; Hwang, Thomas S; Flaxel, Christina J; Wilson, David J; Morrison, John C; Huang, David; Li, Dengwang; Jia, Yali

    2017-03-01

    To improve optic disc boundary detection and peripapillary retinal layer segmentation, we propose an automated approach for structural and angiographic optical coherence tomography. The algorithm was performed on radial cross-sectional B-scans. The disc boundary was detected by searching for the position of Bruch's membrane opening, and retinal layer boundaries were detected using a dynamic programming-based graph search algorithm on each B-scan without the disc region. A comparison of the disc boundary using our method with that determined by manual delineation showed good accuracy, with an average Dice similarity coefficient ≥0.90 in healthy eyes and eyes with diabetic retinopathy and glaucoma. The layer segmentation accuracy in the same cases was on average less than one pixel (3.13 μm).

  15. Automatic Detection of Optic Disc in Retinal Image by Using Keypoint Detection, Texture Analysis, and Visual Dictionary Techniques

    PubMed Central

    Bayır, Şafak

    2016-01-01

    With the advances in the computer field, methods and techniques in automatic image processing and analysis provide the opportunity to detect automatically the change and degeneration in retinal images. Localization of the optic disc is extremely important for determining the hard exudate lesions or neovascularization, which is the later phase of diabetic retinopathy, in computer aided eye disease diagnosis systems. Whereas optic disc detection is fairly an easy process in normal retinal images, detecting this region in the retinal image which is diabetic retinopathy disease may be difficult. Sometimes information related to optic disc and hard exudate information may be the same in terms of machine learning. We presented a novel approach for efficient and accurate localization of optic disc in retinal images having noise and other lesions. This approach is comprised of five main steps which are image processing, keypoint extraction, texture analysis, visual dictionary, and classifier techniques. We tested our proposed technique on 3 public datasets and obtained quantitative results. Experimental results show that an average optic disc detection accuracy of 94.38%, 95.00%, and 90.00% is achieved, respectively, on the following public datasets: DIARETDB1, DRIVE, and ROC. PMID:27110272

  16. Virtual tissue engineering and optic pathways: plotting the course of the axons in the retinal nerve fiber layer.

    PubMed

    Carreras, Francisco Javier; Medina, Javier; Ruiz-Lozano, Mariola; Carreras, Ignacio; Castro, Juan Luis

    2014-04-17

    As part of a larger project on virtual tissue engineering of the optic pathways, we describe the conditions that guide axons extending from the retina to the optic nerve head and formulate algorithms that meet such conditions. To find the entrance site on the optic nerve head of each axon, we challenge the fibers to comply with current models of axonal pathfinding. First, we build a retinal map using a single type of retinal ganglion cell (RGC) using density functions from the literature. Dendritic arbors are equated to receptive fields. Shape and size of retinal surface and optic nerve head (ONH) are defined. A computer model relates each soma to the corresponding entry point of its axon into the optic disc. Weights are given to the heuristics that guide the preference entry order in the nerve. Retinal ganglion cells from the area centralis saturate the temporal section of the disc. Retinal ganglion cells temporal to the area centralis curve their paths surrounding the fovea; some of these cells enter the disc centrally rather than peripherally. Nasal regions of the disc receive mixed axons from the far periphery of the temporal hemiretina, together with axons from the nasal half. The model plots the course of the axon using Bezier curves and compares them with clinical data, for a coincidence level of 86% or higher. Our model is able to simulate basic data of the early optic pathways including certain singularities and to mimic mechanisms operating during development, such as timing and fasciculation. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  17. Automated boundary detection of the optic disc and layer segmentation of the peripapillary retina in volumetric structural and angiographic optical coherence tomography

    PubMed Central

    Zang, Pengxiao; Gao, Simon S.; Hwang, Thomas S.; Flaxel, Christina J.; Wilson, David J.; Morrison, John C.; Huang, David; Li, Dengwang; Jia, Yali

    2017-01-01

    To improve optic disc boundary detection and peripapillary retinal layer segmentation, we propose an automated approach for structural and angiographic optical coherence tomography. The algorithm was performed on radial cross-sectional B-scans. The disc boundary was detected by searching for the position of Bruch’s membrane opening, and retinal layer boundaries were detected using a dynamic programming-based graph search algorithm on each B-scan without the disc region. A comparison of the disc boundary using our method with that determined by manual delineation showed good accuracy, with an average Dice similarity coefficient ≥0.90 in healthy eyes and eyes with diabetic retinopathy and glaucoma. The layer segmentation accuracy in the same cases was on average less than one pixel (3.13 μm). PMID:28663830

  18. A multiscale decomposition approach to detect abnormal vasculature in the optic disc.

    PubMed

    Agurto, Carla; Yu, Honggang; Murray, Victor; Pattichis, Marios S; Nemeth, Sheila; Barriga, Simon; Soliz, Peter

    2015-07-01

    This paper presents a multiscale method to detect neovascularization in the optic disc (NVD) using fundus images. Our method is applied to a manually selected region of interest (ROI) containing the optic disc. All the vessels in the ROI are segmented by adaptively combining contrast enhancement methods with a vessel segmentation technique. Textural features extracted using multiscale amplitude-modulation frequency-modulation, morphological granulometry, and fractal dimension are used. A linear SVM is used to perform the classification, which is tested by means of 10-fold cross-validation. The performance is evaluated using 300 images achieving an AUC of 0.93 with maximum accuracy of 88%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Automated Registration of Multimodal Optic Disc Images: Clinical Assessment of Alignment Accuracy.

    PubMed

    Ng, Wai Siene; Legg, Phil; Avadhanam, Venkat; Aye, Kyaw; Evans, Steffan H P; North, Rachel V; Marshall, Andrew D; Rosin, Paul; Morgan, James E

    2016-04-01

    To determine the accuracy of automated alignment algorithms for the registration of optic disc images obtained by 2 different modalities: fundus photography and scanning laser tomography. Images obtained with the Heidelberg Retina Tomograph II and paired photographic optic disc images of 135 eyes were analyzed. Three state-of-the-art automated registration techniques Regional Mutual Information, rigid Feature Neighbourhood Mutual Information (FNMI), and nonrigid FNMI (NRFNMI) were used to align these image pairs. Alignment of each composite picture was assessed on a 5-point grading scale: "Fail" (no alignment of vessels with no vessel contact), "Weak" (vessels have slight contact), "Good" (vessels with <50% contact), "Very Good" (vessels with >50% contact), and "Excellent" (complete alignment). Custom software generated an image mosaic in which the modalities were interleaved as a series of alternate 5×5-pixel blocks. These were graded independently by 3 clinically experienced observers. A total of 810 image pairs were assessed. All 3 registration techniques achieved a score of "Good" or better in >95% of the image sets. NRFNMI had the highest percentage of "Excellent" (mean: 99.6%; range, 95.2% to 99.6%), followed by Regional Mutual Information (mean: 81.6%; range, 86.3% to 78.5%) and FNMI (mean: 73.1%; range, 85.2% to 54.4%). Automated registration of optic disc images by different modalities is a feasible option for clinical application. All 3 methods provided useful levels of alignment, but the NRFNMI technique consistently outperformed the others and is recommended as a practical approach to the automated registration of multimodal disc images.

  20. Long-term outcomes of pars plana vitrectomy without internal limiting membrane peeling for optic disc pit maculopathy.

    PubMed

    Avci, R; Yilmaz, S; Inan, U U; Kaderli, B; Kurt, M; Yalcinbayir, O; Yildiz, M; Yucel, A

    2013-12-01

    To evaluate the results of surgical treatment of maculopathy secondary to congenital optic pit anomaly with pars plana vitrectomy (PPV), endolaser to the temporal edge of the optic disc and C3F8 tamponade without internal limiting membrane (ILM) peeling. Thirteen eyes of 12 patients with serous macular detachment and/or macular retinoschisis secondary to congenital optic disc pit (ODP) were included in the study. All eyes underwent PPV, posterior hyaloid removal, endolaser photocoagulation on the temporal margin of the optic disc and 12% C3F8 gas tamponade. Anatomic success and functional outcome determined retrospectively by optical coherence tomography and measurement of best corrected visual acuity (BCVA), respectively were the main outcome parameters. Two lines or more improvement in BCVA was obtained in 11 eyes and 6 of these eyes had 20/40 or better BCVA at the final visit. Subretinal or intraretinal fluid was completely resorbed postoperatively in 12 eyes but a little intraretinal fluid persisted in one eye at the 16-month follow-up. Better visual improvement was observed in patients treated by earlier surgical intervention. PPV, C3F8 gas tamponade and endolaser to the optic disc margin without ILM peeling may yield favourable results in the treatment of ODP maculopathy.

  1. Elasticity measurement of nasal cartilage as a function of temperature using optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Liu, Chih Hao; Skryabina, M. N.; Singh, Manmohan; Li, Jiasong; Wu, Chen; Sobol, E.; Larin, Kirill V.

    2015-03-01

    Current clinical methods of reconstruction surgery involve laser reshaping of nasal cartilage. The process of stress relaxation caused by laser heating is the primary method to achieve nasal cartilage reshaping. Based on this, a rapid, non-destructive and accurate elasticity measurement would allow for a more robust reshaping procedure. In this work, we have utilized a phase-stabilized swept source optical coherence elastography (PhSSSOCE) to quantify the Young's modulus of porcine nasal septal cartilage during the relaxation process induced by heating. The results show that PhS-SSOCE was able to monitor changes in elasticity of hyaline cartilage, and this method could potentially be applied in vivo during laser reshaping therapies.

  2. Optic disc segmentation: level set methods and blood vessels inpainting

    NASA Astrophysics Data System (ADS)

    Almazroa, A.; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2017-03-01

    Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head (ONH) pathology such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of ONH abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique is applied. The algorithm is evaluated using a new retinal fundus image dataset called RIGA (Retinal Images for Glaucoma Analysis). In the case of low quality images, a double level set is applied in which the first level set is considered to be a localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as its agreement with manual markings by six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid is 83.9%, and the best agreement is observed between the results of the algorithm and manual markings in 379 images.

  3. The Role of Heparan Sulfate Proteoglycans in Optic Disc and Stalk Morphogenesis

    PubMed Central

    Cai, Zhigang; Grobe, Kay; Zhang, Xin

    2014-01-01

    Background Heparan sulfate proteoglycans (HSPG) are important for embryonic development via the regulation of gradient formation and signaling of multiple growth factors and morphogens. Previous studies have shown that Bmp/Shh/Fgf signaling are required for the regionalization of the optic vesicle (OV) and for the closure of the optic fissure (OF), the disturbance of which underlie ocular anomalies such as microphthalmia, coloboma and optic nerve hypoplasia. Results To study HSPG-dependent coordination of these signaling pathways during mammalian visual system development, we have generated a series of OV-specific mutations in the heparan sulfate (HS) N-sulfotransferase genes (Ndst1 and Ndst2) and HS O-sulfotransferase genes (Hs2st, Hs6st1 and Hs6st2) in mice. Interestingly, the resulting HS undersulfation still allowed for normal retinal neurogenesis and optic fissure closure, but led to defective optic disc and stalk development. The adult mutant animals further developed optic nerve aplasia/hypoplasia and displayed retinal degeneration. We observed that MAPK/ERK signaling was down-regulated in Ndst mutants, and consistent with this, HS-related optic nerve morphogenesis defects in mutant mice could partially be rescued by constitutive Kras activation. Conclusions These results suggest that HSPGs, depending on their HS sulfation pattern, regulate multiple signaling pathways in optic disc and stalk morphogenesis. PMID:24753163

  4. Central corneal thickness and progression of the visual field and optic disc in glaucoma

    PubMed Central

    Chauhan, B C; Hutchison, D M; LeBlanc, R P; Artes, P H; Nicolela, M T

    2005-01-01

    Aims: To determine whether central corneal thickness (CCT) is a significant predictor of visual field and optic disc progression in open angle glaucoma. Methods: Data were obtained from a prospective study of glaucoma patients tested with static automated perimetry and confocal scanning laser tomography every 6 months. Progression was determined using a trend based approach called evidence of change (EOC) analysis in which sectoral ordinal scores based on the significance of regression coefficients of visual field pattern deviation and neuroretinal rim area over time are summed. Visual field progression was also determined using the event based glaucoma change probability (GCP) analysis using both total and pattern deviation. Results: The sample contained 101 eyes of 54 patients (mean (SD) age 56.5 (9.8) years) with a mean follow up of 9.2 (0.7) years and 20.7 (2.3) sets of examinations every 6 months. Lower CCT was associated with worse baseline visual fields and lower mean IOP in the follow up. In the longitudinal analysis CCT was not correlated with the EOC scores for visual field or optic disc change. In the GCP analyses, there was a tendency for groups classified as progressing to have lower CCT compared to non-progressing groups. In a multivariate analyses accounting for IOP, the opposite was found, whereby higher CCT was associated with visual field progression. None of the independent factors were predictive of optic disc progression. Conclusions: In this cohort of patients with established glaucoma, CCT was not a useful index in the risk assessment of visual field and optic disc progression. PMID:16024855

  5. Choroidal thickness in Chinese patients with non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Jiang, Libin; Chen, Lanlan; Qiu, Xiujuan; Jiang, Ran; Wang, Yaxing; Xu, Liang; Lai, Timothy Y Y

    2016-08-31

    Non-arteritic anterior ischemic optic neuropathy (NA-AION) is one of the most common types of ischemic optic neuropathy. Several recent studies suggested that abnormalities of choroidal thickness might be associated with NA-AION. The main objective of this case-control study was to evaluate whether choroidal thickness is an ocular risk factor for the development of NA-AION by evaluating the peripapillary and subfoveal choroidal thicknesses in affected Chinese patients. Forty-four Chinese patients with unilateral NA-AION were recruited and compared with 60 eyes of 60 normal age and refractive-error matched control subjects. Peripapillary and subfoveal choroidal thicknesses were measured by enhanced depth imaging optical coherence tomography. Choroidal thicknesses of eyes with NA-AION and unaffected fellow eyes were compared with normal controls. Choroidal thicknesses of NA-AION eyes with or without optic disc edema were also compared. The correlation between choroidal thickness and retinal nerve fiber layer (RNFL) thickness, logMAR best-corrected visual acuity (BCVA), and the mean deviation (MD) of Humphrey static perimetry in NA-AION eyes were analyzed. The peripapillary choroidal thicknesses at the nasal, nasal inferior and temporal inferior segments in NA-AION eyes with optic disc edema were significantly thicker compared with that of normal subjects (P < 0.05). There was no significant difference in the choroidal thicknesses between the unaffected fellow eyes of NA-AION patients and normal eyes of healthy controls; or between the NA-AION eyes with resolved optic disc edema and normal eyes (all P > 0.05). No significant correlation between choroidal thickness and RNFL thickness, logMAR BCVA and perimetry MD was found in eyes affected by NA-AION (all P > 0.05). Increase in peripapillary choroid thickness in some segments was found in NA-ION eyes with optic disc edema. However, our findings do not support the hypothesis that choroidal thickness is

  6. The relationship between 3D morphology of optic disc and spatial patterns of visual field loss in glaucoma

    NASA Astrophysics Data System (ADS)

    Wang, Mengyu; Wang, Hui; Baniasadi, Neda; Elze, Tobias

    2017-02-01

    Purpose: Optic disc tilt defined over 3D optic disc morphology has been shown to be associated with the location of initial glaucomatous damages. In this work, we study the impact of optic cup depth (OCD) on spatial patterns of visual field loss in glaucoma. Methods: Pairs of reliable Cirrus OCT scans around optic disc and Humphrey visual fields of glaucoma patients without visually significant cataract and age-related macular degeneration were selected. The most recent visit of a randomly selected eye of each patient was chosen. The OCD was automatically calculated on the superior-inferior cross sectional image passing through the optic disc center. The correlations between the mean pattern deviation (PD) of each sector in glaucoma hemifield test (GHT) and Garway-Heath scheme and OCD were evaluated for all severities glaucoma and mild glaucoma (mean deviation >= -5 dB), respectively. Results: 424 eyes of 424 patients passed the data reliability criteria with 346 mild glaucoma patients. For all severities glaucoma, there was no significant correlation between the mean sector PD and OCD. For mild glaucoma, OCD was uniquely correlated to the mean PD of the inferior pericentral sector (r=-0.18, p=0.01) in GHT, which was independent of mean deviation and retinal nerve fiber layer thickness (p<0.001 for both). Conclusion: OCD was uniquely correlated to the vision loss of the inferior pericentral sector in GHT and Garway- Health scheme for mild glaucoma. Future advancement of OCT imaging techniques may provide better clinical diagnosis for early glaucoma by focusing on 3D morphological variation of the optic disc.

  7. Choosing an Optical Disc System: A Guide for Users and Resellers.

    ERIC Educational Resources Information Center

    Vane-Tempest, Stewart

    1995-01-01

    Presents a guide for selecting an optional disc system. Highlights include storage hierarchy; standards; data life cycles; security; implementing an optical jukebox system; optimizing the system; performance; quality and reliability; software; cost of online versus near-line; and growing opportunities. Sidebars provide additional information on…

  8. Automated volumetric evaluation of stereoscopic disc photography

    PubMed Central

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S

    2010-01-01

    PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996

  9. Optic disc drusen: understanding an old problem from a new perspective.

    PubMed

    Hamann, Steffen; Malmqvist, Lasse; Costello, Fiona

    2018-04-16

    Optic disc drusen (ODD) are acellular deposits located in the optic nerve head of up to 2.4% of the population. They may develop as by-products of impaired axonal metabolism in genetically predisposed individuals, in whom a narrow scleral canal is hypothesized to play a role. Although ODD are often considered as benign innocent bystanders, recognized as part of a routine ophthalmological examination, the vast majority of patients with ODD have visual field defects. Optic disc drusen (ODD)-associated complications with severe visual loss, most often due to anterior ischaemic optic neuropathy, are also known to occur. There are no treatments available to prevent or ameliorate the vision loss caused by ODD. In children, the ODD are usually uncalcified and buried within the optic nerve head tissue. In these cases, the condition can be difficult to diagnose, as it often resembles a papilloedema with optic nerve head swelling caused by raised intracranial pressure. During the teenage years, the ODD progressively become more calcified and probably also larger, which allow them to be visible on ophthalmoscopy. With the advent and proper utilization of high-resolution modalities of optical coherence tomography (OCT), it has now become possible to detect even the smallest and most deeply located ODD. This allows for ODD detection at a much earlier developmental stage than has previously been possible and enhances the possibilities of research in underlying mechanisms. A review of the literature on ODD was conducted using the PUBMED database. The review focuses on the current knowledge regarding pathogenesis, diagnostics, clinical disease-tracking methodologies, structure-function relationships and treatment strategies of ODD. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Chronic optic disc swelling overlooked in a diabetic patient with a devastating outcome

    PubMed Central

    Braithwaite, Tasanee; Plant, Gordon T

    2010-01-01

    We present a case of asymmetrical but bilateral, progressive, painless visual deterioration over 5 years to no perception of light, in a 61-year-old male diabetic patient referred for a second opinion. The patient had a chronic history of bilateral diabetic maculopathy and unexplained swelling of the optic discs. He was diagnosed with optic atrophy secondary to pseudotumour cerebri (termed idiopathic intracranial hypertension when underlying causes have been excluded), which was associated with obstructive sleep apnoea. The case highlights the critical importance of identifying and investigating chronic papilloedema for reversible causes; the sometimes subtle presentation of pseudotumour cerebri; and the vital role of visual field testing and diagnostic lumbar puncture for timely diagnosis. It also reminds us that chronic bilateral optic disc swelling is not a normal feature of diabetic eye disease, and that alarm bells should sound if reduced visual acuity seems disproportionate to the degree of maculopathy. PMID:22442651

  11. Ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis.

    PubMed

    Seo, Sam; Lee, Chong Eun; Jeong, Jae Hoon; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook

    2017-03-11

    To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm 2 , P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in

  12. Multimodal segmentation of optic disc and cup from stereo fundus and SD-OCT images

    NASA Astrophysics Data System (ADS)

    Miri, Mohammad Saleh; Lee, Kyungmoo; Niemeijer, Meindert; Abràmoff, Michael D.; Kwon, Young H.; Garvin, Mona K.

    2013-03-01

    Glaucoma is one of the major causes of blindness worldwide. One important structural parameter for the diagnosis and management of glaucoma is the cup-to-disc ratio (CDR), which tends to become larger as glaucoma progresses. While approaches exist for segmenting the optic disc and cup within fundus photographs, and more recently, within spectral-domain optical coherence tomography (SD-OCT) volumes, no approaches have been reported for the simultaneous segmentation of these structures within both modalities combined. In this work, a multimodal pixel-classification approach for the segmentation of the optic disc and cup within fundus photographs and SD-OCT volumes is presented. In particular, after segmentation of other important structures (such as the retinal layers and retinal blood vessels) and fundus-to-SD-OCT image registration, features are extracted from both modalities and a k-nearest-neighbor classification approach is used to classify each pixel as cup, rim, or background. The approach is evaluated on 70 multimodal image pairs from 35 subjects in a leave-10%-out fashion (by subject). A significant improvement in classification accuracy is obtained using the multimodal approach over that obtained from the corresponding unimodal approach (97.8% versus 95.2%; p < 0:05; paired t-test).

  13. Differences in Optical Coherence Tomography Assessment of Bruch Membrane Opening Compared to Stereoscopic Photography for Estimating Cup-to-Disc Ratio.

    PubMed

    Mwanza, Jean-Claude; Huang, Linda Y; Budenz, Donald L; Shi, Wei; Huang, Gintien; Lee, Richard K

    2017-12-01

    To compare the vertical and horizontal cup-to-disc ratio (VCDR, HCDR) by an updated optical coherence tomography (OCT) Bruch membrane opening (BMO) algorithm and stereoscopic optic disc photograph readings by glaucoma specialists. Reliability analysis. A total of 195 eyes (116 glaucoma and 79 glaucoma suspect) of 99 patients with stereoscopic photographs and OCT scans of the optic discs taken during the same visit were compared. Optic disc photographs were read by 2 masked glaucoma specialists for VCDR and HCDR estimation. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess the agreement between photograph reading and OCT in estimating CDR. OCT images computed significantly larger VCDR and HCDR than photograph reading before and after stratifying eyes based on disc size (P < .001). The difference in CDR estimates between the 2 methods was equal to or greater than 0.2 in 29% and 35% of the eyes for VCDR and HCDR, respectively, with a mean difference of 0.3 in each case. The ICCs between the readers and OCT ranged between 0.50 and 0.63. The size of disagreement in VCDR correlated weakly with cup area in eyes with medium (r 2  = 0.10, P = .008) and large (r 2  = 0.09, P = .007) discs. OCT and photograph reading by clinicians agree poorly in CDR assessment. The difference in VCDR between the 2 methods was depended on cup area in medium and large discs. These differences should be considered when making conclusions regarding CDRs in clinical practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. High-resolution imaging of the retinal nerve fiber layer in normal eyes using adaptive optics scanning laser ophthalmoscopy.

    PubMed

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Arakawa, Naoko; Oshima, Susumu; Shibata, Naohisa; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2012-01-01

    To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created. AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001) AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.

  15. Spontaneous Resolution of Long-Standing Macular Detachment due to Optic Disc Pit with Significant Visual Improvement.

    PubMed

    Parikakis, Efstratios A; Chatziralli, Irini P; Peponis, Vasileios G; Karagiannis, Dimitrios; Stratos, Aimilianos; Tsiotra, Vasileia A; Mitropoulos, Panagiotis G

    2014-01-01

    To report a case of spontaneous resolution of a long-standing serous macular detachment associated with an optic disc pit, leading to significant visual improvement. A 63-year-old female presented with a 6-month history of blurred vision and micropsia in her left eye. Her best-corrected visual acuity was 6/24 in the left eye, and fundoscopy revealed serous macular detachment associated with optic disc pit, which was confirmed by optical coherence tomography (OCT). The patient was offered vitrectomy as a treatment alternative, but she preferred to be reviewed conservatively. Three years after initial presentation, neither macular detachment nor subretinal fluid was evident in OCT, while the inner segment/outer segment (IS/OS) junction line was intact. Her visual acuity was improved from 6/24 to 6/12 in her left eye, remaining stable at the 6-month follow-up after resolution. We present a case of spontaneous resolution of a long-standing macular detachment associated with an optic disc pit with significant visual improvement, postulating that the integrity of the IS/OS junction line may be a prognostic factor for final visual acuity and suggesting OCT as an indicator of visual prognosis and the probable necessity of a surgical management.

  16. The collagen structure of bovine intervertebral disc studied using polarization-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Matcher, Stephen J.; Winlove, C. Peter; Gangnus, Sergei V.

    2004-04-01

    Polarization-sensitive optical coherence tomography (PS-OCT) is used to measure the birefringence properties of bovine intervertebral disc and equine flexor tendon. For equine tendon the birefringence Dgrn is (6.0 ± 0.2) × 10-3 at a wavelength of 1.3 µm. This is somewhat larger than the values reported for bovine tendon. The surface region of the annulus fibrosus of a freshly excised intact bovine intervertebral disc displays an identical value of birefringence, Dgrn = (6.0 ± 0.6) × 10-3 at 1.3 µm. The nucleus pulposus does not display birefringence, the measured apparent value of Dgrn = (0.39 ± 0.01) × 10-3 being indistinguishable from the effects of depolarization due to multiple scattering. A clear difference is found between the depth-resolved retardance of equine tendon and that of bovine intervertebral disc. This apparently relates to the lamellar structure of the latter tissue, in which the collagen fibre orientation alternates between successive lamellae. A semi-empirical model based on Jones calculus shows that the measurements are in reasonable agreement with previous optical and x-ray data. These results imply that PS-OCT could be a useful tool to study collagen organization within the intervertebral disc in vitro and possibly in vivo and its variation with applied load and disease.

  17. The Transcription Factor Foxg1 Promotes Optic Fissure Closure in the Mouse by Suppressing Wnt8b in the Nasal Optic Stalk

    PubMed Central

    Smith, Rowena; Huang, Yu-Ting; Tian, Tian; Vojtasova, Dominika; Mesalles-Naranjo, Oscar; Price, David J.

    2017-01-01

    During vertebrate eye morphogenesis, a transient fissure forms at its inferior part, known as the optic fissure. This will gradually close, giving rise to a healthy, spherical optic cup. Failure of the optic fissure to close gives rise to an ocular disorder known as coloboma. During this developmental process, Foxg1 is expressed in the optic neuroepithelium, with highest levels of expression in the nasal optic stalk. Foxg1−/− mutant mice have microphthalmic eyes with a large ventral coloboma. We found Wnt8b expression upregulated in the Foxg1−/− optic stalk and hypothesized that, similar to what is observed in telencephalic development, Foxg1 directs development of the optic neuroepithelium through transcriptional suppression of Wnt8b. To test this, we generated Foxg1−/−;Wnt8b−/− double mutants of either sex and found that the morphology of the optic cup and stalk and the closure of the optic fissure were substantially rescued in these embryos. This rescue correlates with restored Pax2 expression in the anterior tip of the optic fissure. In addition, although we do not find evidence implicating altered proliferation in the rescue, we observe a significant increase in apoptotic cell density in Foxg1−/−;Wnt8b−/− double mutants compared with the Foxg1−/− single mutant. Upregulation of Wnt/β-catenin target molecules in the optic cup and stalk may underlie the molecular and morphological defects in the Foxg1−/− mutant. Our results show that proper optic fissure closure relies on Wnt8b suppression by Foxg1 in the nasal optic stalk to maintain balanced apoptosis and Pax2 expression in the nasal and temporal edges of the fissure. SIGNIFICANCE STATEMENT Coloboma is an ocular disorder that may result in a loss of visual acuity and accounts for ∼10% of childhood blindness. It results from errors in the sealing of the optic fissure (OF), a transient structure at the bottom of the eye. Here, we investigate the colobomatous phenotype of the

  18. Myopic Maculopathy and Optic Disc Changes in Highly Myopic Young Asian Eyes and Impact on Visual Acuity.

    PubMed

    Koh, Victor; Tan, Colin; Tan, Pei Ting; Tan, Marcus; Balla, Vinay; Nah, Gerard; Cheng, Ching-Yu; Ohno-Matsui, Kyoko; Tan, Mellisa M H; Yang, Adeline; Zhao, Paul; Wong, Tien Yin; Saw, Seang-Mei

    2016-04-01

    To determine the prevalence and risk factors of myopic maculopathy and specific optic disc and macular changes in highly myopic eyes of young Asian adults and their impact on visual acuity. Prospective cross-sectional study. In total, 593 highly myopic (spherical equivalent refraction [SER] less than -6.00 diopters [D]) and 156 emmetropic (SER between -1.00 and +1.00 D) male participants from a population-based survey were included. All participants underwent standardized medical interviews, ophthalmic examination, and color fundus photographs. These photographs were graded systematically to determine the presence of optic disc and macular lesions. Myopic maculopathy was classified based on the International Classification of Myopic Maculopathy. The mean age was 21.1 ± 1.2 years. The mean SER for the highly myopic and emmetropic group was -8.87 ± 2.11 D and 0.40 ± 0.39 D, respectively (P < .001). Compared to emmetropic eyes, highly myopic eyes were significantly more likely to have optic disc tilt, peripapillary atrophy (PPA), posterior staphyloma, chorioretinal atrophy, and myopic maculopathy (all P < .001). The main findings included PPA (98.3%), disc tilt (22.0%), posterior staphyloma (32.0%), and chorioretinal atrophy (8.3%). Myopic maculopathy was present in 8.3% of highly myopic eyes and was associated with older age (odds ratio [OR] 1.66; 95% CI: 1.22, 2.26), reduced choroidal thickness (OR 0.99; 95% CI: 0.98, 0.99), and increased axial length (AL) (OR 1.52; 95% CI: 1.06, 2.19). The presence of disc tilt, posterior staphyloma, and chorioretinal atrophy were associated with reduced visual acuity. Our study showed that myopia-related changes of the optic disc and macula were common in highly myopic eyes even at a young age. The risk factors for myopic maculopathy include increased age, longer AL, and reduced choroidal thickness. Some of these changes were associated with reduced central visual function. Copyright © 2016 Elsevier Inc. All rights

  19. Surgical approach and optic coherence tomographic evaluation of optic disc anomaly in association with serous macular detachment.

    PubMed

    Güven, Dilek; Balcıoğlu, Nihal; Türker, Cağrı; Baydar, Yasemin; Sendül, Yekta

    2013-12-01

    Serous macular detachment (SMD) may accompany optic disc pit (ODP) and cause visual loss if untreated. We want to present different therapeutic approaches and interesting optical coherence tomography (OCT) findings in three consecutive cases. In this case series, two patients with SMD and one patient with partial macular detachment and inferior retinal detachment accompanying ODP were evaluated before and after surgical intervention clinically and by spectral-domain OCT. The patients were 44 (case 1), 22 (case 2) and 24 (case 3) years old. Pars plana vitrectomy (PPV) + silicone oil + laser, PPV + sulfur hexafluoride gas (SF6) + laser and pneumatic retinopexy were applied, respectively. The patients were followed for 18, 15 and 14 months. Preoperative best-corrected visual acuities (BCVAs) were 5/100, 7/10 and counting fingers at 1 m. Vision improved in all cases with resolution of subretinal fluid. Final BCVAs were 3/10, 10/10 and 1/10, respectively. OCT images revealed optic disc anomaly details and changes after surgical intervention, photoreceptor outer segment alterations at the detached area and macular surface changes. Surgical intervention should be tailored individually in cases with SMD. OCT is efficient for in vivo evaluation of this pathological condition and anatomical outcomes of surgery.

  20. Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT.

    PubMed

    Knight, O'Rese J; Girkin, Christopher A; Budenz, Donald L; Durbin, Mary K; Feuer, William J

    2012-03-01

    To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P ≤ .005) except rim area (P = .22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r(2) = 0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups.

  1. Effect of Race, Age, and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD-OCT

    PubMed Central

    Knight, O’Rese J.; Girkin, Christopher A.; Budenz, Donald L.; Durbin, Mary K.; Feuer, William J.

    2017-01-01

    Objective To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. Methods In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. Results The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P≤.005) except rim area (P=.22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r2=0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. Conclusions There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups. PMID:22411660

  2. The relationship between central corneal thickness and optic disc size in patients with primary open-angle glaucoma in a hospital-based population.

    PubMed

    Terai, Naim; Spoerl, Eberhard; Pillunat, Lutz E; Kuhlisch, Eberhard; Schmidt, Eckart; Boehm, Andreas G

    2011-09-01

    To investigate the relationship between central corneal thickness (CCT) and optic disc size in patients with primary open-angle glaucoma (POAG) in a hospital-based population. Data for the right eyes of 1435 White patients with POAG were included in a retrospective hospital-based study. All eyes underwent optic nerve head imaging using Heidelberg Retina Tomograph II (HRT II; Heidelberg Engineering, Heidelberg, Germany) and CCT measurement by ultrasound corneal pachymetry. Eyes with prior intraocular or corneal surgery were excluded. Low-quality HRT II images were also excluded. The impact of age, gender, CCT, intraocular pressure, cylindrical and spherical refractive error as independent factors on optic disc size was investigated in a multiple linear regression analysis. The data for 1104 right eyes qualified for participation in the study. The median age of these patients was 65 years. The median CCT was 547 μm (25th-75th percentile 522-575 μm). The median optic disc size was 2.21 mm(2) (25th-75th percentile 1.89-2.60 mm(2)). Multiple linear regression analysis revealed that age (p = 0.001), CCT (p = 0.001) and spherical equivalent (p = 0.049) were correlated to disc size according to the following formula: disc area = -0.004 × age - 0.001 × CCT - 0.014 × spherical equivalent +3.290. R(2) of the whole model was 0.021. Univariate regression analysis between age and disc area provided R(2) = 0.008 with p = 0.002. Univariate regression analysis between disc area and CCT provided R(2) = 0.005 with p = 0.02. In this retrospective hospital-based study we could not detect a clinically relevant correlation between optic disc size and CCT. The correlation between CCT and disc size and between age and disc size were statistically significant, but the R(2) values were very low. The results of the study are biased because of its hospital-based design, so the results of the study need to be confirmed in a large population-based study. © 2009 The Authors. Journal

  3. Diagnostic power of optic disc morphology, peripapillary retinal nerve fiber layer thickness, and macular inner retinal layer thickness in glaucoma diagnosis with fourier-domain optical coherence tomography.

    PubMed

    Huang, Jehn-Yu; Pekmezci, Melike; Mesiwala, Nisreen; Kao, Andrew; Lin, Shan

    2011-02-01

    To evaluate the capability of the optic disc, peripapillary retinal nerve fiber layer (P-RNFL), macular inner retinal layer (M-IRL) parameters, and their combination obtained by Fourier-domain optical coherent tomography (OCT) in differentiating a glaucoma suspect from perimetric glaucoma. Two hundred and twenty eyes from 220 patients were enrolled in this study. The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis on the basis of OCT parameters and demographic factors. The diagnostic power of these parameters was evaluated with receiver operating characteristic (ROC) curve analysis. The diagnostic power in the clinically relevant range (specificity ≥ 80%) was presented as the partial area under the ROC curve (partial AROC). The individual OCT parameter with the largest AROC and partial AROC in the high specificity (≥ 80%) range were cup/disc vertical ratio (AROC = 0.854 and partial AROC = 0.142) for the optic disc parameters, average thickness (AROC = 0.919 and partial AROC = 0.147) for P-RNFL parameters, inferior hemisphere thickness (AROC = 0.871 and partial AROC = 0.138) for M-IRL parameters, respectively. The linear discriminant function further enhanced the ability in detecting perimetric glaucoma (AROC = 0.970 and partial AROC = 0.172). Average P-RNFL thickness is the optimal individual OCT parameter to detect perimetric glaucoma. Simultaneous evaluation on disc morphology, P-RNFL, and M-IRL thickness can improve the diagnostic accuracy in diagnosing glaucoma.

  4. Automated Quantification of Volumetric Optic Disc Swelling in Papilledema Using Spectral-Domain Optical Coherence Tomography

    PubMed Central

    Wang, Jui-Kai; Kardon, Randy H.; Kupersmith, Mark J.; Garvin, Mona K.

    2012-01-01

    Purpose. To develop an automated method for the quantification of volumetric optic disc swelling in papilledema subjects using spectral-domain optical coherence tomography (SD-OCT) and to determine the extent that such volumetric measurements correlate with Frisén scale grades (from fundus photographs) and two-dimensional (2-D) peripapillary retinal nerve fiber layer (RNFL) and total retinal (TR) thickness measurements from SD-OCT. Methods. A custom image-analysis algorithm was developed to obtain peripapillary circular RNFL thickness, TR thickness, and TR volume measurements from SD-OCT volumes of subjects with papilledema. In addition, peripapillary RNFL thickness measures from the commercially available Zeiss SD-OCT machine were obtained. Expert Frisén scale grades were independently obtained from corresponding fundus photographs. Results. In 71 SD-OCT scans, the mean (± standard deviation) resulting TR volumes for Frisén scale 0 to scale 4 were 11.36 ± 0.56, 12.53 ± 1.21, 14.42 ± 2.11, 17.48 ± 2.63, and 21.81 ± 3.16 mm3, respectively. The Spearman's rank correlation coefficient was 0.737. Using 55 eyes with valid Zeiss RNFL measurements, Pearson's correlation coefficient (r) between the TR volume and the custom algorithm's TR thickness, the custom algorithm's RNFL thickness, and Zeiss' RNFL thickness was 0.980, 0.929, and 0.946, respectively. Between Zeiss' RNFL and the custom algorithm's RNFL, and the study's TR thickness, r was 0.901 and 0.961, respectively. Conclusions. Volumetric measurements of the degree of disc swelling in subjects with papilledema can be obtained from SD-OCT volumes, with the mean volume appearing to be roughly linearly related to the Frisén scale grade. Using such an approach can provide a more continuous, objective, and robust means for assessing the degree of disc swelling compared with presently available approaches. PMID:22599584

  5. Poland syndrome associated with 'morning glory' syndrome (coloboma of the optic disc).

    PubMed Central

    Pisteljić, D T; Vranjesević, D; Apostolski, S; Pisteljić, D D

    1986-01-01

    A 12 year old girl with the Poland syndrome and the 'morning glory' syndrome is described. The patient presented with absence of the left pectoralis major muscle, hypoplasia of the left arm, symbrachydactyly, and ipsilateral coloboma of the optic disc. This is the first report of the association of these two congenital anomalies. Images PMID:3018249

  6. Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT.

    PubMed

    Kim, Young Kook; Ha, Ahnul; Lee, Won June; Jeoung, Jin Wook; Park, Ki Ho

    2017-12-01

    To introduce the measurement method of optic disc cup surface depth using spectral-domain optical coherence tomography (SD-OCT) and then evaluate the rates of cup surface depression at 3 different stages of glaucoma. We retrospectively identified 52 eyes with preperimetric glaucoma, 56 with mild-or-moderate glaucoma and 50 with severe glaucoma and followed them for at least 48 months. Eyes were imaged using SD-OCT (Cirrus HD-OCT) at 12-month intervals. The mean cup surface depth was calculated using the following formula: Cup volume/(disc area×average cup-to-disc ratio)-200 μm. The rates of mean cup surface depression (μm/y) were significantly greater in mild-or-moderate glaucoma (-7.96±1.03) than in preperimetric (-3.11±0.61) and severe glaucoma (-0.70±0.12; all P<0.001). The percentile rates of mean cup surface depression (%/y) were significantly greater than those of average of retinal nerve fiber layer (RNFL) thinning (%/y) in preperimetric glaucoma (-1.64±0.12 vs. -1.11±0.07; P<0.001) and mild-or-moderate glaucoma (-4.20±0.33 vs. -3.14±0.19; P<0.001); and conversely, in severe glaucoma, mean cup surface depth changed slower than did average RNFL thickness (-0.64±0.06 vs. -0.75±0.08%/y; P<0.001). In early-to-moderate glaucoma, the cup surface depth changed faster than did the RNFL thickness. These results signify the possibility that SD-OCT-based estimation of cup surface depth might be useful for monitoring of glaucoma development and progression.

  7. Incidence and rates of visual field progression after longitudinally measured optic disc change in glaucoma.

    PubMed

    Chauhan, Balwantray C; Nicolela, Marcelo T; Artes, Paul H

    2009-11-01

    To determine whether glaucoma patients with progressive optic disc change have subsequent visual field progression earlier and at a faster rate compared with those without disc change. Prospective, longitudinal, cohort study. Eighty-one patients with open-angle glaucoma. Patients underwent confocal scanning laser tomography and standard automated perimetry every 6 months. The complete follow-up was divided into initial and subsequent periods. Two initial periods-first 3 years (Protocol A) and first half of the total follow-up (Protocol B)-were used, with the respective remainder being the subsequent follow-up. Disc change during the initial follow-up was determined with liberal, moderate, or conservative criteria of the Topographic Change Analysis. Subsequent field progression was determined with significant pattern deviation change in >or=3 locations (criterion used in the Early Manifest Glaucoma Trial). As a control analysis, field change during the initial follow-up was determined with significant pattern deviation change in >or=1, >or=2, or >or=3 locations. Survival time to subsequent field progression, rates of mean deviation (MD) change, and positive and negative likelihood ratios. The median (interquartile range) total follow-up was 11.0 (8.0-12.0) years with 22 (18-24) examinations. More patients had disc changes during the initial follow-up compared with field changes. The mean time to field progression was consistently shorter (protocol A, 0.8-1.7 years; protocol B, 0.3-0.7 years) in patients with prior disc change. In the control analysis, patients with prior field change had statistically earlier subsequent field progression (protocol A, 2.9-3.0 years; protocol B, 0.7-0.9). Similarly, patients with either prior disc or field change always had worse mean rates of subsequent MD change, although the distributions overlapped widely. Patients with subsequent field progression were up to 3 times more likely to have prior disc change compared with those

  8. The Spectrum of Optic Disc Ischemia in Patients Younger than 50 Years (An Amercian Ophthalmological Society Thesis)

    PubMed Central

    Arnold, Anthony C.; Costa, Roberta M. S.; Dumitrascu, Oana M.

    2013-01-01

    Purpose: To identify the spectrum of clinical and fluorescein angiographic features of optic disc ischemia in patients younger than 50 years. Methods: This retrospective comparative case series from a university consultative neuro-ophthalmology practice consisted of two phases. The first compared 108 cases of nonarteritic anterior ischemic optic neuropathy in patients younger than 50 years (NAIONy) to a cohort of 108 cases in patients 50 years or older (NAIONo). Predisposing risk factors, fluorescein angiographic features, and clinical course were compared. In the second phase, 12 cases of diabetic papillopathy under age 50 were assessed by fluorescein angiographic criteria for evidence of optic disc ischemia and compared to patients with NAIONy. Results: NAIONy comprised 108 (12.7%) of 848 NAION cases reviewed. Chronic renal failure with dialysis and migraine were more common in NAIONy. Fellow eye involvement rate was significantly higher for NAIONy patients (46/108, 42.6%) than for NAIONo patients (32/108, 29.6%). Fluorescein angiographic features of ischemia were documented in 44 (81.5%) of 54 eyes studied. In one case, these features were documented in pre-NAION edema. Diabetic papillopathy demonstrated delayed filling consistent with ischemia in 7 of 10 (70.0%), without significant visual field loss. Conclusions: Ischemic optic neuropathy in patients younger than 50 years is not rare. Fellow eye involvement is more frequent in younger patients. Fluorescein angiography confirmation of impaired perfusion in multiple syndromes of optic neuropathy corroborates a spectrum of optic disc ischemia ranging from perfusion delay without visual loss to severely impaired perfusion and visual loss and incorporates optic neuropathies previously considered nonischemic. PMID:24167327

  9. Ametropia, retinal anatomy, and OCT abnormality patterns in glaucoma. 2. Impacts of optic nerve head parameters

    NASA Astrophysics Data System (ADS)

    Baniasadi, Neda; Wang, Mengyu; Wang, Hui; Jin, Qingying; Elze, Tobias

    2017-12-01

    Clinicians use retinal nerve fiber layer thickness (RNFLT) measured by optical coherence tomography (OCT) as an adjunct to glaucoma diagnosis. Ametropia is accompanied by changes to the optic nerve head (ONH), which may affect how OCT machines mark RNFLT measurements as abnormal. These changes in abnormality patterns may bias glaucoma diagnosis. Here, we investigate the relationship between OCT abnormality patterns and the following ONH-related and ametropia-associated parameters on 421 eyes of glaucoma patients: optic disc tilt and torsion, central retinal vessel trunk location (CRVTL), and nasal and temporal retinal curvature adjacent to ONH, quantified as nasal/temporal slopes of the inner limiting membrane. We applied multivariate logistic regression with abnormality marks as regressands to 40,401 locations of the peripapillary region and generated spatial maps of locations of false positive/negative abnormality marks independent of glaucoma severity. Effects of torsion and temporal slope were negligible. The effect of tilt could be explained by covariation with ametropia. For CRVTL/nasal slope, abnormality pattern shifts at 7.2%/23.5% of the peripapillary region were detected, respectively, independent of glaucoma severity and ametropia. Therefore, CRVTL and nasal curvature should be included in OCT RNFLT norms. Our spatial location maps may aid clinicians to improve diagnostic accuracy.

  10. Eyes with Suspicious Appearance of the Optic Disc and Normal Intraocular Pressure: Using Clinical and Epidemiological Characteristics to Differentiate Those with and without Glaucoma.

    PubMed

    Dias, Diego T; Ushida, Michele; Sousa, Marina C; Dorairaj, Syril; Biteli, Luis G; Leite, Mauro T; Paranhos, Augusto; Prata, Tiago S

    2016-01-01

    Among all glaucoma suspects, eyes with optic nerve head features suspicious or suggestive of early glaucoma are probably those that offer the greatest challenge for clinicians. In contrast with the robust longitudinal data published on ocular hypertension, there is no specific management guideline for these patients. Therefore, evaluating eyes with suspicious optic disc appearance and normal intraocular pressure (IOP), we sought to investigate potential differences in clinical and epidemiological characteristics to differentiate those with normal-tension glaucoma (NTG) from those with presumed large physiological optic disc cups (pLPC). In this observational case-control study, we consecutively enrolled individuals with pLPC and NTG. All eyes had vertical cup-to-disc ratio (VCDR)≥0.6 and untreated IOP<21 mmHg. Glaucomatous eyes had reproducible visual field defects. Eyes with pLPC required normal visual fields and ≥30 months of follow-up with no evidence of glaucomatous neuropathy. Clinical and epidemiological parameters were compared between groups. Eighty-four individuals with pLPC and 40 NTG patients were included. Regarding our main results, NTG patients were significantly older and with a higher prevalence of Japanese descendants (p<0.01). Not only did pLPC eyes have smaller mean VCDR, but also larger optic discs (p≤0.04). There were no significant differences for gender, central corneal thickness, and spherical equivalent (p≥0.38). Significant odds ratios (OR) were found for race (OR = 2.42; for Japanese ancestry), age (OR = 1.05), VCDR (OR = 5.03), and disc size (OR = 0.04; p≤0.04). In conclusion, in patients with suspicious optic disc and normal IOP, those with older age, Japanese ancestry, smaller optic discs, and larger VCDR are more likely to have NTG, and therefore, deserve deeper investigation and closer monitoring.

  11. Automated Detection of Optic Disc in Fundus Images

    NASA Astrophysics Data System (ADS)

    Burman, R.; Almazroa, A.; Raahemifar, K.; Lakshminarayanan, V.

    Optic disc (OD) localization is an important preprocessing step in the automated image detection of fundus image infected with glaucoma. An Interval Type-II fuzzy entropy based thresholding scheme along with Differential Evolution (DE) is applied to determine the location of the OD in the right of left eye retinal fundus image. The algorithm, when applied to 460 fundus images from the MESSIDOR dataset, shows a success rate of 99.07 % for 217 normal images and 95.47 % for 243 pathological images. The mean computational time is 1.709 s for normal images and 1.753 s for pathological images. These results are important for automated detection of glaucoma and for telemedicine purposes.

  12. New insights into the genetics of primary open-angle glaucoma based on meta-analyses of intraocular pressure and optic disc characteristics

    PubMed Central

    Springelkamp, Henriët; Iglesias, Adriana I.; Mishra, Aniket; Höhn, René; Wojciechowski, Robert; Khawaja, Anthony P.; Nag, Abhishek; Wang, Ya Xing; Wang, Jie Jin; Cuellar-Partida, Gabriel; Gibson, Jane; Bailey, Jessica N. Cooke; Vithana, Eranga N.; Gharahkhani, Puya; Boutin, Thibaud; Ramdas, Wishal D.; Zeller, Tanja; Luben, Robert N.; Yonova-Doing, Ekaterina; Viswanathan, Ananth C.; Yazar, Seyhan; Cree, Angela J.; Haines, Jonathan L.; Koh, Jia Yu; Souzeau, Emmanuelle; Wilson, James F.; Amin, Najaf; Müller, Christian; Venturini, Cristina; Kearns, Lisa S.; Kang, Jae Hee; Tham, Yih Chung; Zhou, Tiger; van Leeuwen, Elisabeth M.; Nickels, Stefan; Sanfilippo, Paul; Liao, Jiemin; van der Linde, Herma; Zhao, Wanting; van Koolwijk, Leonieke M.E.; Zheng, Li; Rivadeneira, Fernando; Baskaran, Mani; van der Lee, Sven J.; Perera, Shamira; de Jong, Paulus T.V.M.; Oostra, Ben A.; Uitterlinden, André G.; Fan, Qiao; Hofman, Albert; Tai, E-Shyong; Vingerling, Johannes R.; Sim, Xueling; Wolfs, Roger C.W.; Teo, Yik Ying; Lemij, Hans G.; Khor, Chiea Chuen; Willemsen, Rob; Lackner, Karl J.; Aung, Tin; Jansonius, Nomdo M.; Montgomery, Grant; Wild, Philipp S.; Young, Terri L.; Burdon, Kathryn P.; Hysi, Pirro G.; Pasquale, Louis R.; Wong, Tien Yin; Klaver, Caroline C.W.; Hewitt, Alex W.; Jonas, Jost B.; Mitchell, Paul; Lotery, Andrew J.; Foster, Paul J.; Vitart, Veronique; Pfeiffer, Norbert; Craig, Jamie E.; Mackey, David A.; Hammond, Christopher J.; Wiggs, Janey L.; Cheng, Ching-Yu; van Duijn, Cornelia M.; MacGregor, Stuart

    2017-01-01

    Abstract Primary open-angle glaucoma (POAG), the most common optic neuropathy, is a heritable disease. Siblings of POAG cases have a ten-fold increased risk of developing the disease. Intraocular pressure (IOP) and optic nerve head characteristics are used clinically to predict POAG risk. We conducted a genome-wide association meta-analysis of IOP and optic disc parameters and validated our findings in multiple sets of POAG cases and controls. Using imputation to the 1000 genomes (1000G) reference set, we identified 9 new genomic regions associated with vertical cup-disc ratio (VCDR) and 1 new region associated with IOP. Additionally, we found 5 novel loci for optic nerve cup area and 6 for disc area. Previously it was assumed that genetic variation influenced POAG either through IOP or via changes to the optic nerve head; here we present evidence that some genomic regions affect both IOP and the disc parameters. We characterized the effect of the novel loci through pathway analysis and found that pathways involved are not entirely distinct as assumed so far. Further, we identified a novel association between CDKN1A and POAG. Using a zebrafish model we show that six6b (associated with POAG and optic nerve head variation) alters the expression of cdkn1a. In summary, we have identified several novel genes influencing the major clinical risk predictors of POAG and showed that genetic variation in CDKN1A is important in POAG risk. PMID:28073927

  13. Sensitivity and specificity of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen and optic disc oedema: optic disc drusen and oedema.

    PubMed

    Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores

    2013-03-01

    Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.

  14. Automatic optic disc segmentation based on image brightness and contrast

    NASA Astrophysics Data System (ADS)

    Lu, Shijian; Liu, Jiang; Lim, Joo Hwee; Zhang, Zhuo; Tan, Ngan Meng; Wong, Wing Kee; Li, Huiqi; Wong, Tien Yin

    2010-03-01

    Untreated glaucoma leads to permanent damage of the optic nerve and resultant visual field loss, which can progress to blindness. As glaucoma often produces additional pathological cupping of the optic disc (OD), cupdisc- ratio is one measure that is widely used for glaucoma diagnosis. This paper presents an OD localization method that automatically segments the OD and so can be applied for the cup-disc-ratio based glaucoma diagnosis. The proposed OD segmentation method is based on the observations that the OD is normally much brighter and at the same time have a smoother texture characteristics compared with other regions within retinal images. Given a retinal image we first capture the ODs smooth texture characteristic by a contrast image that is constructed based on the local maximum and minimum pixel lightness within a small neighborhood window. The centre of the OD can then be determined according to the density of the candidate OD pixels that are detected by retinal image pixels of the lowest contrast. After that, an OD region is approximately determined by a pair of morphological operations and the OD boundary is finally determined by an ellipse that is fitted by the convex hull of the detected OD region. Experiments over 71 retinal images of different qualities show that the OD region overlapping reaches up to 90.37% according to the OD boundary ellipses determined by our proposed method and the one manually plotted by an ophthalmologist.

  15. Optical-to-virial velocity ratios of local disc galaxies from combined kinematics and galaxy-galaxy lensing

    NASA Astrophysics Data System (ADS)

    Reyes, R.; Mandelbaum, R.; Gunn, J. E.; Nakajima, R.; Seljak, U.; Hirata, C. M.

    2012-10-01

    In this paper, we measure the optical-to-virial velocity ratios Vopt/V200c of disc galaxies in the Sloan Digital Sky Survey (SDSS) at a mean redshift of = 0.07 and with stellar masses 109 < M* < 1011 M⊙. Vopt/V200c, the ratio of the circular velocity measured at the optical radius of the disc (˜10 kpc) to that at the virial radius of the dark matter halo (˜150 kpc), is a powerful observational constraint on disc galaxy formation. It links galaxies to their dark matter haloes dynamically and constrains the total mass profile of disc galaxies over an order of magnitude in length scale. For this measurement, we combine Vopt derived from the Tully-Fisher relation (TFR) from Reyes et al. with V200c derived from halo masses measured with galaxy-galaxy lensing. In anticipation of this combination, we use similarly selected galaxy samples for both the TFR and lensing analysis. For three M* bins with lensing-weighted mean stellar masses of 0.6, 2.7 and 6.5 × 1010 M⊙, we find halo-to-stellar mass ratios M200c/M* = 41, 23 and 26, with 1σ statistical uncertainties of around 0.1 dex, and Vopt/V200c = 1.27 ± 0.08, 1.39 ± 0.06 and 1.27 ± 0.08 (1σ), respectively. Our results suggest that the dark matter and baryonic contributions to the mass within the optical radius are comparable, if the dark matter halo profile has not been significantly modified by baryons. The results obtained in this work will serve as inputs to and constraints on disc galaxy formation models, which will be explored in future work. Finally, we note that this paper presents a new and improved galaxy shape catalogue for weak lensing that covers the full SDSS Data Release 7 footprint.

  16. Blindness associated with nasal/paranasal lymphoma in a stallion.

    PubMed

    Sano, Yuto; Okamoto, Minoru; Ootsuka, Youhei; Matsuda, Kazuya; Yusa, Shigeki; Taniyama, Hiroyuki

    2017-03-23

    A 29-year-old stallion presented with bilateral blindness following the chronic purulent nasal drainage. The mass occupied the right caudal nasal cavity and right paranasal sinuses including maxillary, palatine and sphenoidal sinuses, and the right-side turbinal and paranasal septal bones, and cribriform plate of ethmoid bone were destructively replaced by the mass growth. The right optic nerve was invaded and involved by the mass, and the left optic nerve and optic chiasm were compressed by the mass which was extended and invaded the skull base. Histologically, the optic nerves and optic chiasm were degenerated, and the mass was diagnosed as lymphoma which was morphologically and immunohistochemically classified as a diffuse large B-cell lymphoma. Based on these findings, the cause of the blindness in the stallion was concluded to be due to the degeneration of the optic nerves and chiasm associated with lymphoma occurring in the nasal and paranasal cavities. To the best of our knowledge, this is the first report of the equine blindness with optic nerve degeneration accompanied by lymphoma.

  17. A compact disc under skimming light rays

    NASA Astrophysics Data System (ADS)

    De Luca, R.; Di Mauro, M.; Fiore, O.; Naddeo, A.

    2018-03-01

    The optical properties of a compact disc (CD) under "skimming" light rays have been analyzed. We have noticed that a clear green line can be detected when the disc is irradiated with light rays coming from a lamp in such a way that only those skimming the CD, held horizontally, are selected. We provide a physical interpretation of this phenomenon on the basis of elementary optics concepts. Extension of these concepts to digital versatile discs (DVDs) is given.

  18. [Maculopathy in case of the pit of the disc].

    PubMed

    Kolár, P

    2005-09-01

    The pit of the disc is a congenital anomaly of the optic nerve disc. The prevalence is 1/11 000 patients. On the affected side, the optic disc is in 85% of cases larger than the disc of the other healthy eye. The pit of the disc is very often associated with the presence of the cilioretinal artery. Maculopathy in congenital pit of the optic nerve disc was described in the early 30's of the last century by Calhoun. The average age of the patients is roughly 30 years of age (20-40 years). The complementary examination method, which may help to clarify anatomical conditions of the macular region, is the optical coherence tomography. The defect of the optic disc of different depth caused by the pit and maculopathy caused by retinoschisis communicating with the temporal rim of the disc are found. This case report refers to a 29 years old man with disturbing relative central scotoma and decreased vision for one month in his right eye, who underwent classical three-ports pars plana vitrectomy with expansive gas tamponade. On the basis of differential diagnosis discretion, the temporally localized pit of the disc accompanied by maculopathy due to retonoschisis was detemined. The surgical treatment by means of three-ports pars plana vitrectomy and peeling of the inner limiting membrane with expansive gas tamponade restored in our patient the physiological macular structure followed by improvement of the best-corrected visual acuity. No complications were noticed during the surgery or after it as well. Among the differential diagnoses, it is necessary to eliminate other possible causes of maculopathy in young patients as well as other congenital anomalies of the optic disc, which may be related to the maculopathy. Maculopathy following the pit of the optic nerve disc represents relatively rare diagnostic entity. According to the literature, the natural course of this disease results in very low final best-corrected visual acuity, often worse than 5/50 (0,1 or 20/200). The

  19. Optic Disc Melanocytoma Report of 5 Patients From Singapore With a Review of the Literature.

    PubMed

    Lee, Elin; Sanjay, Srinivasan

    2015-01-01

    The aim of this study was to report the clinical features of optic disc melanocytoma (ODMC). This study was a retrospective case series. Five patients (6 eyes) with ODMC followed up over a mean duration of 3 years (range, 4-61 months) were included in this series. The mean age of diagnosis was 55.2 years with Chinese female predominance. Four of 6 ODMCs were unilateral with predominance to the left side. Four patients had visual acuity of 6/9 or better at presentation, and all ODMCs were discovered incidentally. All ODMCs were black, with an average size of 0.8 disc diameter and partially covering the optic disc. Five of 6 ODMCs were inferiorly located and involved adjacent choroid and retina. Three of 6 ODMCs had ill-defined borders. Fundus fluorescein angiogram findings in 1 patient showed blocked fluorescence due to pigments. No loss of visual acuity of 2 or more Snellen lines, ODMC enlargement, or malignant transformation were noted in any patients during follow-up. There were no local complications. Ocular and systemic associations were not seen. Our case series did not show any features of progression during our follow-up. Annual fundoscopic examinations are still important to detect enlargement and malignant transformation.

  20. Method and system for assigning a confidence metric for automated determination of optic disc location

    DOEpatents

    Karnowski, Thomas P [Knoxville, TN; Tobin, Jr., Kenneth W.; Muthusamy Govindasamy, Vijaya Priya [Knoxville, TN; Chaum, Edward [Memphis, TN

    2012-07-10

    A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.

  1. Optic disc detection using ant colony optimization

    NASA Astrophysics Data System (ADS)

    Dias, Marcy A.; Monteiro, Fernando C.

    2012-09-01

    The retinal fundus images are used in the treatment and diagnosis of several eye diseases, such as diabetic retinopathy and glaucoma. This paper proposes a new method to detect the optic disc (OD) automatically, due to the fact that the knowledge of the OD location is essential to the automatic analysis of retinal images. Ant Colony Optimization (ACO) is an optimization algorithm inspired by the foraging behaviour of some ant species that has been applied in image processing for edge detection. Recently, the ACO was used in fundus images to detect edges, and therefore, to segment the OD and other anatomical retinal structures. We present an algorithm for the detection of OD in the retina which takes advantage of the Gabor wavelet transform, entropy and ACO algorithm. Forty images of the retina from DRIVE database were used to evaluate the performance of our method.

  2. Nasal carriage of Methicillin- and Mupirocin-resistant S. aureus among health care workers in a tertiary care hospital.

    PubMed

    Agarwal, Loveleena; Singh, Amit Kumar; Sengupta, Chandrim; Agarwal, Amitabh

    2015-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) ranks top among the nosocomial pathogens. Nasal formulation of mupirocin is found to eradicate MRSA from colonized individuals, but the emergence of resistant strains is a matter of concern. Nasal swabs were collected from 200 health care workers (HCWs) who were screened for MRSA. Kirby-Bauer disc diffusion method was used to perform antibiotic susceptibility test. MRSA detection was done using a cefoxitin 30 µg disc and interpreted according to the Clinical and Laboratory Standards Institute guidelines. Determination of mupirocin resistance was performed using Epsilometer test (E-test). About 14% of HCWs showed nasal carriage of MRSA. Nursing orderlies were the predominant carriers. E-test showed four mupirocin resistant isolates. The antibiogram of the MRSA isolates revealed the higher resistance to antibiotics as compared to methicillin-sensitive Staphylococcus aureus. All the MRSA isolates were sensitive to linezolid. HCWs in our hospital showed high nasal carriage rate of MRSA, particularly the nursing orderlies which is statistically significant. It is advisable to detect mupirocin resistance among the isolates obtained from the HCWs so that in case of resistance, alternative treatment should be sought.

  3. Minimal invasive localization of the germinal disc in ovo for subsequent chicken sexing using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Burkhardt, Anke; Geissler, Stefan; Cimalla, Peter; Walther, Julia; Koch, Edmund

    2010-02-01

    Reason for using optical coherence tomography (OCT) to locate the germinal disc is the questionable and ethically alarming killing of male layer chickens because for the layer line only the females are necessary. To avoid this and to protect the animal rights, the sex of the fertilized chicken egg has to be determined as early as possible in the unincubated state. Because the information whether the chick becomes male or female can be found in the germinal disc an accurate localization for sexing is essential. The germinal disc is located somewhere on top of the yolk and has a diameter of approximately 4 - 5 mm. Different imaging methods like ultrasonography, 3D-X-ray micro computed tomography and magnetic resonance imaging were used for localization until now, but found to be impractical. The goal of this study is to prove if OCT can be a moderate approach for the precise in ovo localization. Because the eggshell is an impenetrable barrier for OCT and to minimize the penetration of germs a very small hole is placed in the eggshell and a fan-shaped optical scanning pattern is used.

  4. Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya.

    PubMed

    Bastawrous, Andrew; Giardini, Mario Ettore; Bolster, Nigel M; Peto, Tunde; Shah, Nisha; Livingstone, Iain A T; Weiss, Helen A; Hu, Sen; Rono, Hillary; Kuper, Hannah; Burton, Matthew

    2016-02-01

    Visualization and interpretation of the optic nerve and retina are essential parts of most physical examinations. To design and validate a smartphone-based retinal adapter enabling image capture and remote grading of the retina. This validation study compared the grading of optic nerves from smartphone images with those of a digital retinal camera. Both image sets were independently graded at Moorfields Eye Hospital Reading Centre. Nested within the 6-year follow-up (January 7, 2013, to March 12, 2014) of the Nakuru Eye Disease Cohort in Kenya, 1460 adults (2920 eyes) 55 years and older were recruited consecutively from the study. A subset of 100 optic disc images from both methods were further used to validate a grading app for the optic nerves. Data analysis was performed April 7 to April 12, 2015. Vertical cup-disc ratio for each test was compared in terms of agreement (Bland-Altman and weighted κ) and test-retest variability. A total of 2152 optic nerve images were available from both methods (also 371 from the reference camera but not the smartphone, 170 from the smartphone but not the reference camera, and 227 from neither the reference camera nor the smartphone). Bland-Altman analysis revealed a mean difference of 0.02 (95% CI, -0.21 to 0.17) and a weighted κ coefficient of 0.69 (excellent agreement). The grades of an experienced retinal photographer were compared with those of a lay photographer (no health care experience before the study), and no observable difference in image acquisition quality was found. Nonclinical photographers using the low-cost smartphone adapter were able to acquire optic nerve images at a standard that enabled independent remote grading of the images comparable to those acquired using a desktop retinal camera operated by an ophthalmic assistant. The potential for task shifting and the detection of avoidable causes of blindness in the most at-risk communities makes this an attractive public health intervention.

  5. Libraries in the Information Age: Where Are the Microcomputer and Laser Optical Disc Technologies Taking Us?

    ERIC Educational Resources Information Center

    Chen, Ching-chih

    1986-01-01

    This discussion of information technology and its impact on library operations and services emphasizes the development of microcomputer and laser optical disc technologies. Libraries' earlier responses to bibliographic utilities, online databases, and online public access catalogs are described, and future directions for library services are…

  6. Optical methods for diagnostics and feedback control in laser-induced regeneration of spine disc and joint cartilages

    NASA Astrophysics Data System (ADS)

    Sobol, Emil; Sviridov, Alexander; Omeltchenko, Alexander; Baum, Olga; Baskov, Andrey; Borchshenko, Igor; Golubev, Vladimir; Baskov, Vladimir

    2011-03-01

    In 1999 we have introduced a new approach for treatment of spine diseases based on the mechanical effect of nondestructive laser radiation on the nucleus pulposus of the intervertebral disc. Laser reconstruction of spine discs (LRD) involves puncture of the disc and non-destructive laser irradiation of the nucleus pulposus to activate reparative processes in the disc tissues. In vivo animal study has shown that LRD allows activate the growth of hyaline type cartilage in laser affected zone. The paper considers physical processes and mechanisms of laser regeneration, presents results of investigations aimed to optimize laser settings and to develop feedback control system for laser reparation in cartilages of spine and joints. The results of laser reconstruction of intervertebral discs for 510 patients have shown substantial relief of back pain for 90% of patients. Laser technology has been experimentally tested for reparation of traumatic and degenerative diseases in joint cartilage of 20 minipigs. It is shown that laser regeneration of cartilage allows feeling large (more than 5 mm) defects which usually never repair on one's own. Optical techniques have been used to promote safety and efficacy of the laser procedures.

  7. The Advanced Glaucoma Intervention Study (AGIS): 10. Variability among academic glaucoma subspecialists in assessing optic disc notching.

    PubMed

    Gaasterland, D E; Blackwell, B; Dally, L G; Caprioli, J; Katz, L J; Ederer, F

    2001-01-01

    An analysis of data from the Advanced Glaucoma Intervention Study (AGIS) has found eyes reported to have partial optic disc rim notching (not to the edge) at baseline to have less risk of subsequent visual field loss than eyes with no notching. Because this is counterintuitive and because classification of notching had not been defined in the AGIS protocol, we have assessed AGIS ophthalmologists interobserver and intraobserver agreement on notching. Fourteen glaucoma subspecialists classified notching in 26 pairs of stereoscopic disc photographs of eyes with mild to severe glaucomatous optic neuropathy. They classified images as showing either no notching, notching not to the edge, or notching to the edge. Several hours later, 10 of them classified the same images a second time. In an analysis of interobserver agreement, of 26 stereoscopic images, a plurality of ophthalmologists classified notching as absent in 9 (35%), as present but not to the edge in 7 (27%), and as present and not to the edge in 10 (38%). All 14 ophthalmologists (100%) agreed on the classification of 7 (27%) of the images, and 13 of the 14 ophthalmologists (93%) agreed on the classification of 4 additional images (15%). Of these 11 images with at least 93% agreement, notching was reported as absent in 3 (27%) and to the edge in 8 (73%). In the remaining 15 images, there was substantial disagreement about whether notching was present and, if so, whether it was to the edge. In an analysis of intraobserver agreement, none of the 10 ophthalmologists who completed the viewing a second time classified all eyes exactly the same as the first time, though 5 ophthalmologists made 4 or fewer reclassifications. Overall, 80% of the original classifications were reproduced on second reading. Of the initial classifications that were not reproduced, slightly more than half were first classified as having notching not to the edge. Without definitions or examples of optic disc rim notching, the glaucoma

  8. The Advanced Glaucoma Intervention Study (AGIS): 10. Variability among academic glaucoma subspecialists in assessing optic disc notching.

    PubMed Central

    Gaasterland, D E; Blackwell, B; Dally, L G; Caprioli, J; Katz, L J; Ederer, F

    2001-01-01

    PURPOSE: An analysis of data from the Advanced Glaucoma Intervention Study (AGIS) has found eyes reported to have partial optic disc rim notching (not to the edge) at baseline to have less risk of subsequent visual field loss than eyes with no notching. Because this is counterintuitive and because classification of notching had not been defined in the AGIS protocol, we have assessed AGIS ophthalmologists interobserver and intraobserver agreement on notching. METHODS: Fourteen glaucoma subspecialists classified notching in 26 pairs of stereoscopic disc photographs of eyes with mild to severe glaucomatous optic neuropathy. They classified images as showing either no notching, notching not to the edge, or notching to the edge. Several hours later, 10 of them classified the same images a second time. RESULTS: In an analysis of interobserver agreement, of 26 stereoscopic images, a plurality of ophthalmologists classified notching as absent in 9 (35%), as present but not to the edge in 7 (27%), and as present and not to the edge in 10 (38%). All 14 ophthalmologists (100%) agreed on the classification of 7 (27%) of the images, and 13 of the 14 ophthalmologists (93%) agreed on the classification of 4 additional images (15%). Of these 11 images with at least 93% agreement, notching was reported as absent in 3 (27%) and to the edge in 8 (73%). In the remaining 15 images, there was substantial disagreement about whether notching was present and, if so, whether it was to the edge. In an analysis of intraobserver agreement, none of the 10 ophthalmologists who completed the viewing a second time classified all eyes exactly the same as the first time, though 5 ophthalmologists made 4 or fewer reclassifications. Overall, 80% of the original classifications were reproduced on second reading. Of the initial classifications that were not reproduced, slightly more than half were first classified as having notching not to the edge. CONCLUSION: Without definitions or examples of optic

  9. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.

    PubMed

    Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka

    2018-03-01

    To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.

  10. Circumplanetary discs around young giant planets: a comparison between core-accretion and disc instability

    NASA Astrophysics Data System (ADS)

    Szulágyi, J.; Mayer, L.; Quinn, T.

    2017-01-01

    Circumplanetary discs can be found around forming giant planets, regardless of whether core accretion or gravitational instability built the planet. We carried out state-of-the-art hydrodynamical simulations of the circumplanetary discs for both formation scenarios, using as similar initial conditions as possible to unveil possible intrinsic differences in the circumplanetary disc mass and temperature between the two formation mechanisms. We found that the circumplanetary discs' mass linearly scales with the circumstellar disc mass. Therefore, in an equally massive protoplanetary disc, the circumplanetary discs formed in the disc instability model can be only a factor of 8 more massive than their core-accretion counterparts. On the other hand, the bulk circumplanetary disc temperature differs by more than an order of magnitude between the two cases. The subdiscs around planets formed by gravitational instability have a characteristic temperature below 100 K, while the core-accretion circumplanetary discs are hot, with temperatures even greater than 1000 K when embedded in massive, optically thick protoplanetary discs. We explain how this difference can be understood as the natural result of the different formation mechanisms. We argue that the different temperatures should persist up to the point when a full-fledged gas giant forms via disc instability; hence, our result provides a convenient criterion for observations to distinguish between the two main formation scenarios by measuring the bulk temperature in the planet vicinity.

  11. Opportunistic detection of glaucomatous optic discs within a diabetic retinopathy screening service.

    PubMed

    Treacy, Maxwell P; O'Neill, Evelyn C; Murphy, Melissa; O'Toole, Louise; Delaney, Yvonne; O'Brien, Colm; Connell, Paul P

    2016-06-10

    To determine the prevalence of glaucoma among patients referred to a glaucoma service with suspicious disc photographs from the diabetic retinopathy (DR) screening program. A clinical audit of all patients attending a single-center DR screening program in the Mater Misericordiae University Hospital, Dublin, between July 2010 and October 2011 was conducted with a minimum follow-up of 30 months. The DR screening service uses trained technician graders to assess 2-field color retinal photographs for the features of DR. Recently, the service was enhanced so that optic discs are also assessed for signs of glaucoma. In the 16-month study period, 3,697 diabetic patients were photographed. Following photograph grading, 91 (2.46%) were judged to require referral for assessment at the glaucoma clinic. Of these, 63 (69.23%) presented for assessment. Thirteen patients (20.63%) were diagnosed with glaucoma, comprising 7 cases of low-tension glaucoma and 6 cases of primary open-angle glaucoma. Thirty-six patients (57.14%) were classified as glaucoma suspects and 14 patients (22.22%) were discharged back to the DR screening program following normal ocular examination. Only 6 (9.52%) of the 63 patients examined had an intraocular pressure greater than 21 mm Hg. The assessment of DR screening photographs for signs of glaucomatous optic nerve damage should be considered as part of a strategy to improve glaucoma case detection and to reduce the burden of this disease on society.

  12. Optically thin core accretion: how planets get their gas in nearly gas-free discs

    NASA Astrophysics Data System (ADS)

    Lee, Eve J.; Chiang, Eugene; Ferguson, Jason W.

    2018-05-01

    Models of core accretion assume that in the radiative zones of accreting gas envelopes, radiation diffuses. But super-Earths/sub-Neptunes (1-4 R⊕, 2-20 M⊕) point to formation conditions that are optically thin: their modest gas masses are accreted from short-lived and gas-poor nebulae reminiscent of the transparent cavities of transitional discs. Planetary atmospheres born in such environments can be optically thin to both incident starlight and internally generated thermal radiation. We construct time-dependent models of such atmospheres, showing that super-Earths/sub-Neptunes can accrete their ˜1 per cent-by-mass gas envelopes, and super-puffs/sub-Saturns their ˜20 per cent-by-mass envelopes, over a wide range of nebular depletion histories requiring no fine tuning. Although nascent atmospheres can exhibit stratospheric temperature inversions affected by atomic Fe and various oxides that absorb strongly at visible wavelengths, the rate of gas accretion remains controlled by the radiative-convective boundary (rcb) at much greater pressures. For dusty envelopes, the temperature at the rcb Trcb ≃ 2500 K is still set by H2 dissociation; for dust-depleted envelopes, Trcb tracks the temperature of the visible or thermal photosphere, whichever is deeper, out to at least ˜5 au. The rate of envelope growth remains largely unchanged between the old radiative diffusion models and the new optically thin models, reinforcing how robustly super-Earths form as part of the endgame chapter in disc evolution.

  13. [Posterior vitrectomy with gas endotamponade and retinal laser therapy in treatment of patients with macular complications of the optic disc pit].

    PubMed

    Cywiński, Adam; Kałużny, Jakub; Ferda, Daniela; Piwońska-Lobermajer, Anna

    2015-01-01

    Retrospective evaluation of functional and anatomical treatment outcomes in patients with macular cornplications of optic disc pit. 9 patients (eyes) underwent central posterior vitrectomy in conjunction with posterior vitreous detachment, retinal laser therapy to the optic disc pit area and endotamponade with expansile gas. It was followed by the patient's forced positioning (recommended for a few days especially at night), which ended the treatment protocol. Improved anatomical relationships, accompanied by functional improvement were achieved in each reported case. The resolution of macular lesions was slow, lasting even for several months. Too long delay in performing the surgery (over 5 months since the onset of visual impairment) was associated with the development of retinal complications, mainly macular hole formation, most likely caused by the long-term ischemia. The central posterior vitrectomy combined with posterior vitreous detachment, laser therapy, andd expansile gas tamponade offers good outcomes in patients with retinal complications of optic disc pit. Surgery performed shortly after the onset of visual dysfunction gives the best functional outcomes. Restoration of normal anatomical relationships is a long-term process. In some cases, though, these abnormalities may not resolve completely.

  14. Chromosome 6p25 deletion syndrome: report of a case with optic disc coloboma and review of published ophthalmic findings.

    PubMed

    Beby, Francis; Des Portes, Vincent; Till, Marianne; Mottolese, Carmine; Denis, Philippe

    2012-12-01

    The 6p25 deletion syndrome is a rare disorder characterized by Dandy-Walker malformation, congenital heart defects, developmental delay, dysmorphic facial features, and malformations of the anterior segment of the eye with a risk for glaucoma. Here we report a child harboring a cryptic de novo 6p25 deletion, bilateral optic disc coloboma and characteristic anterior segment anomalies. We review reported ophthalmic findings in patients with this syndrome. Retrospective case review of a 4-day-old male with Dandy-Walker malformation and cardiac defects who was referred with a suspected diagnosis of iris coloboma. The ophthalmic examination showed bilateral corectopia associated with posterior embryotoxon. Fundus examination revealed bilateral optic disc excavation, which was diagnosed as colobomatous because of its configuration and stability over time. Because of the association of posterior embryotoxon with Dandy-Walker malformation, a terminal 6p deletion syndrome was clinically suspected. Array comparative genomic hybridization (CGH) and fluorescence in situ hybridization (FISH) studies revealed a 3.2 Mb deletion at 6p25.2p25.3 including the FOXC1 gene. Neither unaffected parent carried this deletion. Optic disc colobomas may be found in patients carrying a 6p25 deletion. This has the potential to confound assessment of affected children for glaucoma and intracranial hypertension.

  15. Localization of optic disc and fovea in retinal images using intensity based line scanning analysis.

    PubMed

    Kamble, Ravi; Kokare, Manesh; Deshmukh, Girish; Hussin, Fawnizu Azmadi; Mériaudeau, Fabrice

    2017-08-01

    Accurate detection of diabetic retinopathy (DR) mainly depends on identification of retinal landmarks such as optic disc and fovea. Present methods suffer from challenges like less accuracy and high computational complexity. To address this issue, this paper presents a novel approach for fast and accurate localization of optic disc (OD) and fovea using one-dimensional scanned intensity profile analysis. The proposed method utilizes both time and frequency domain information effectively for localization of OD. The final OD center is located using signal peak-valley detection in time domain and discontinuity detection in frequency domain analysis. However, with the help of detected OD location, the fovea center is located using signal valley analysis. Experiments were conducted on MESSIDOR dataset, where OD was successfully located in 1197 out of 1200 images (99.75%) and fovea in 1196 out of 1200 images (99.66%) with an average computation time of 0.52s. The large scale evaluation has been carried out extensively on nine publicly available databases. The proposed method is highly efficient in terms of quickly and accurately localizing OD and fovea structure together compared with the other state-of-the-art methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Measurement of retinal nerve fiber layer thickness in eyes with optic disc swelling by using scanning laser polarimetry and optical coherence tomography.

    PubMed

    Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa

    2014-01-01

    The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss.

  17. Measurement of retinal nerve fiber layer thickness in eyes with optic disc swelling by using scanning laser polarimetry and optical coherence tomography

    PubMed Central

    Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa

    2014-01-01

    Background The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Methods Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. Results No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. Conclusion In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss. PMID:24379653

  18. Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images

    NASA Astrophysics Data System (ADS)

    Hatanaka, Yuji; Noudo, Atsushi; Muramatsu, Chisako; Sawada, Akira; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2010-03-01

    Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. First, the blood vessels were erased from the image and then the edge of optic disc was then detected by use of a canny edge detection filter. Twenty profiles were then obtained around the center of the optic disc in the vertical direction on blue channel of the color image, and the profile was smoothed by averaging these profiles. After that, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method. These results indicated that this method can be useful for the analysis of the optic disc in glaucoma examinations.

  19. Accretion Discs Around Black Holes: Developement of Theory

    NASA Astrophysics Data System (ADS)

    Bisnovatyi-Kogan, G. S.

    Standard accretion disk theory is formulated which is based on the local heat balance. The energy produced by a turbulent viscous heating is supposed to be emitted to the sides of the disc. Sources of turbulence in the accretion disc are connected with nonlinear hydrodynamic instability, convection, and magnetic field. In standard theory there are two branches of solution, optically thick, and optically thin. Advection in accretion disks is described by the differential equations what makes the theory nonlocal. Low-luminous optically thin accretion disc model with advection at some suggestions may become advectively dominated, carrying almost all the energy inside the black hole. The proper account of magnetic filed in the process of accretion limits the energy advected into a black hole, efficiency of accretion should exceed ˜ 1/4 of the standard accretion disk model efficiency.

  20. Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph.

    PubMed

    Vizzeri, Gianmarco; Bowd, Christopher; Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M

    2008-08-01

    Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Observational clinical study. Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered on the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 microm), superiorly (106.2 microm), or inferiorly (104.1 microm) displaced scans and the centered scans (106.4 microm). However, a significant difference (analysis of variance with Dunnett's test: F=8.82, P<0.0001) was found between temporally displaced scans (115.8 microm) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. In normal eyes, average RNFL thickness measurements are robust and similar with significant superior, inferior, and nasal scan

  1. 3D optic disc reconstruction via a global fundus stereo algorithm.

    PubMed

    Bansal, M; Sizintsev, M; Eledath, J; Sawhney, H; Pearson, D J; Stone, R A

    2013-01-01

    This paper presents a novel method to recover 3D structure of the optic disc in the retina from two uncalibrated fundus images. Retinal images are commonly uncalibrated when acquired clinically, creating rectification challenges as well as significant radiometric and blur differences within the stereo pair. By exploiting structural peculiarities of the retina, we modified the Graph Cuts computational stereo method (one of current state-of-the-art methods) to yield a high quality algorithm for fundus stereo reconstruction. Extensive qualitative and quantitative experimental evaluation (where OCT scans are used as 3D ground truth) on our and publicly available datasets shows the superiority of the proposed method in comparison to other alternatives.

  2. Optic disc laceration with combined retinal artery and vein occlusion following penetrating injury.

    PubMed

    Lee, Mun-Wai; Lee, Shu-Yen; Ong, Sze-Guan

    2007-07-01

    Ocular trauma is a major cause of unilateral blindness and male adults in the working age group have been found to have higher rates of ocular injury. A case of a work-related penetrating ocular trauma with an intraocular foreign body causing an optic disc laceration and consequently a combined retinal arterial and venous occlusion is presented. The patient did not recover useful vision despite early surgical intervention. This case highlights an unusual sequelae following penetrating ocular trauma as well as the importance of safety eyewear for individuals in high-risk occupations.

  3. A Diagnostic Calculator for Detecting Glaucoma on the Basis of Retinal Nerve Fiber Layer, Optic Disc, and Retinal Ganglion Cell Analysis by Optical Coherence Tomography.

    PubMed

    Larrosa, José Manuel; Moreno-Montañés, Javier; Martinez-de-la-Casa, José María; Polo, Vicente; Velázquez-Villoria, Álvaro; Berrozpe, Clara; García-Granero, Marta

    2015-10-01

    The purpose of this study was to develop and validate a multivariate predictive model to detect glaucoma by using a combination of retinal nerve fiber layer (RNFL), retinal ganglion cell-inner plexiform (GCIPL), and optic disc parameters measured using spectral-domain optical coherence tomography (OCT). Five hundred eyes from 500 participants and 187 eyes of another 187 participants were included in the study and validation groups, respectively. Patients with glaucoma were classified in five groups based on visual field damage. Sensitivity and specificity of all glaucoma OCT parameters were analyzed. Receiver operating characteristic curves (ROC) and areas under the ROC (AUC) were compared. Three predictive multivariate models (quantitative, qualitative, and combined) that used a combination of the best OCT parameters were constructed. A diagnostic calculator was created using the combined multivariate model. The best AUC parameters were: inferior RNFL, average RNFL, vertical cup/disc ratio, minimal GCIPL, and inferior-temporal GCIPL. Comparisons among the parameters did not show that the GCIPL parameters were better than those of the RNFL in early and advanced glaucoma. The highest AUC was in the combined predictive model (0.937; 95% confidence interval, 0.911-0.957) and was significantly (P = 0.0001) higher than the other isolated parameters considered in early and advanced glaucoma. The validation group displayed similar results to those of the study group. Best GCIPL, RNFL, and optic disc parameters showed a similar ability to detect glaucoma. The combined predictive formula improved the glaucoma detection compared to the best isolated parameters evaluated. The diagnostic calculator obtained good classification from participants in both the study and validation groups.

  4. Vasodilatory effect of L-arginine on isolated rabbit and human posterior ciliary arteries in vitro and increased optic disc blood flow in vivo.

    PubMed

    Chuman, Hideki; Sugimoto, Takako; Nao-I, Nobuhisa

    2017-12-01

    This study aimed to clarify the vasodilatory effect of L-arginine on isolated rabbit and human posterior ciliary arteries (PCAs) and to investigate changes in optic disc blood flow after an infusion of L-arginine in vivo. Vascular ring segments were mounted on a double myograph system. After obtaining maximal contraction following administration of high-K solution, L-arginine was administrated. Six volunteers received an intravenous drip infusion of 100 ml of L-arginine or saline. Changes in optic disc blood flow were measured by laser speckle flowgraphy. L-arginine relaxed high-K solution-induced contracted rabbit PCAs. Carboxy-PTIO (nitric oxide scavenger) and L-NAME (nitric oxide synthase inhibitor) inhibited L-arginine-induced relaxation in rabbit PCAs. After removal of the endothelium of the rabbit PCAs, L-arginine still relaxed rabbit PCAs. L-arginine relaxed human PCAs, despite the lack of nitric oxide production. In the L-arginine infusion group, the mean blur rate was significantly greater than that of the control group in vivo. L-arginine has both nitric oxide-dependent and independent vasodilatory effect on high K- induced contractions in isolated rabbit and human PCAs. L-arginine increased optic disc blood flow in vivo.

  5. The absence of a thin disc in M81*

    NASA Astrophysics Data System (ADS)

    Young, A. J.; McHardy, I.; Emmanoulopoulos, D.; Connolly, S.

    2018-06-01

    We present the results of simultaneous Suzaku and NuSTAR observations of the nearest low-luminosity active galactic nucleus (LLAGN), M81*. The spectrum is well described by a cut-off power law plus narrow emission lines from Fe K α, Fe xxv, and Fe xxvi. There is no evidence of Compton reflection from an optically thick disc, and we obtain the strongest constraint on the reflection fraction in M81* to date, with a best-fitting value of R = 0.0 with an upper limit of R < 0.1. The Fe K α line may be produced in optically thin, N_H = 1 × 10^{23} cm^{-2}, gas located in the equatorial plane that could be the broad line region. The ionized iron lines may originate in the hot, inner accretion flow. The X-ray continuum shows significant variability on ˜40 ks time-scales suggesting that the primary X-ray source is ˜100 s of gravitational radii in size. If this X-ray source illuminates any putative optically thick disc, the weakness of reflection implies that such a disc lies outside a few ×103 gravitational radii. An optically thin accretion flow inside a truncated optically thick disc appears to be a common feature of LLAGN that are accreting at only a tiny fraction of the Eddington limit.

  6. Optical coherence tomography in papilledema and pseudopapilledema with and without optic nerve head drusen.

    PubMed

    Bassi, Shikha Talwar; Mohana, Kuppuswamy Parthasarthy

    2014-12-01

    To compare the spectral domain optical coherence tomography (SD-OCT) findings of the optic disc and the peripapillary retina of patients with a true papilledema and pseudopapilledema with and without optic nerve head drusen (ONHD). Retrospective Case Control Study. Peripapillary retinal nerve fiber layer (PPRNFL) thickness as depicted by SD-OCT of 94 eyes of 66 patients with papilledema (30 eyes), pseudopapiledema (31 eyes), and normal controls (33 eyes) was analyzed. The mean RNFL thickness, total retinal thickness (TRT) at a superior and inferior edge of the disc and the quadrant wise topography of increased RNFL were compared in all three groups. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) were calculated for all the parameters. The median RNFL thickness was 185.4 (129.5-349.3 μm), 122.3 (109-156.3 μm) and 91.62 ± 7 μm in papilledema, pseudopapilledema, and controls, respectively. Papilledema group had thicker PPRNFL in all quadrants except temporal quadrant. TRT was thicker in papilledema and pseudopapilledema compared to controls. ONHD could be directly visualized as high reflective clumps in the sub-retinal space or the RNFL in 30 eyes. Increased RNFL thickness in all four quadrants was noted 43.3% in papilledema and 9.7% in pseudopapilledema. Normal RNFL thickness in all four quadrants was noted in 0% in papilledema and 32.3% in pseudopapilledema. Nasal RNFL had the highest AROC (0.792) indicating high diagnostic ability to differentiate papilledema from pseudopapilledema. SD-OCT can be used as a tool to differentiate between papilledema and pseudopapilledema.

  7. Presentation and management of nasal foreign bodies at a tertiary children's hospital in an American metro area.

    PubMed

    Scholes, Melissa A; Jensen, Emily L

    2016-09-01

    To examine rates of otolaryngology intervention in children presenting to our emergency department with nasal foreign bodies, factors associated with otolaryngology involvement, rates of complications, and details on nasal button battery exposure. All patients presenting with a nasal foreign body to Children's Hospital Colorado from 2007 to 2012 were identified. Factors leading to referral to otolaryngology and operative intervention were examined, as well as complications. 102 patients were included. 36 (35%) patients were referred to the otolaryngology clinic, of which 58.9% required operating room intervention. 66 (64.7%) children had their nasal foreign bodies removed in the emergency room, however 30 (45%) of these were removed by an otolaryngology resident or attending physician. Overall, 64.7% of nasal foreign bodies required removal by otolaryngology. Of the 15 objects removed in the operating room, six were button batteries. No septal perforations occurred as a result of nasal button battery exposure. Multivariable logistic regression showed two significant predictors of OR removal: age and disc shaped objects. While emergency department providers are comfortable attempting removal of nasal foreign bodies, there was a high rate of otolaryngology intervention. Based on this data, there is a need to educate emergency room providers on nasal anatomy and techniques for nasal foreign body removal. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Comparison of optic area measurement using fundus photography and optical coherence tomography between optic nerve head drusen and control subjects.

    PubMed

    Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia

    2013-03-01

    To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  9. Nasal Carriage Rate of Methicillin Resistant Staphylococcus aureus among Health Care Workers at a Tertiary Care Hospital in Kathmandu, Nepal.

    PubMed

    Khatri, S; Pant, N D; Bhandari, R; Shrestha, K L; Shrestha, C D; Adhikari, N; Poudel, A

    2017-01-01

    Methicillin-resistant Staphylococcus aureus is one of the most common causes of nosocomial infections. Due to its multidrug resistant nature; infections due to Methicillin-resistant Staphylococcus aureus are often very difficult to treat. Colonized health care workers are the important sources of Methicillin-resistant Staphylococcus aureus. The objectives of this study were to determine the nasal carriage rate of Methicillin-resistant Staphylococcus aureus among health care workers at Kathmandu Medical College and Teaching Hospital, Nepal and to assess their antimicrobial susceptibility patterns. A cross sectional study was conducted among 252 health care workers from July to November 2013. Mannitol salt agar was used to culture the nasal swabs. Antimicrobial susceptibility testing was performed by Kirby-Bauer disc diffusion technique following Clinical and Laboratory Standards Institute guidelines. Methicillin-resistant Staphylococcus aureus strains were confirmed by using cefoxitin disc and by determining the minimum inhibitory concentration of oxacillin by agar dilution method. Of 252 healthcare workers, 46(18.3%) were positive for Staphylococcus aureus among which 19(41.3%) were Methicillin-resistant Staphylococcus aureus carriers. Overall rate of nasal carriage of Methicillin-resistant Staphylococcus aureus was 7.5% (19/252).The higher percentages of lab personnel were nasal carriers of S. aureus (31.6%) and Methicillin-resistant Staphylococcus aureus (10.5%).The percentages of nasal carriage of S. aureus (35.7%) and Methicillin-resistant Staphylococcus aureus (14.3%) were highest in the health care workers from post operative department. Higher percentage of Methicillin-resistant Staphylococcus aureus were susceptible toward amikacin (100%) and vancomycin (100%) followed by cotrimoxazole (84.2%). High rates of nasal carriage of S. aureus and Methicillin-resistant Staphylococcus aureus were observed among the healthcare workers, which indicate the need of

  10. Photoreceptor disc shedding in the living human eye

    PubMed Central

    Kocaoglu, Omer P.; Liu, Zhuolin; Zhang, Furu; Kurokawa, Kazuhiro; Jonnal, Ravi S.; Miller, Donald T.

    2016-01-01

    Cone photoreceptors undergo a daily cycle of renewal and shedding of membranous discs in their outer segments (OS), the portion responsible for light capture. These physiological processes are fundamental to maintaining photoreceptor health, and their dysfunction is associated with numerous retinal diseases. While both processes have been extensively studied in animal models and postmortem eyes, little is known about them in the living eye, in particular human. In this study, we report discovery of the optical signature associated with disc shedding using a method based on adaptive optics optical coherence tomography (AO-OCT) in conjunction with post-processing methods to track and monitor individual cone cells in 4D. The optical signature of disc shedding is characterized by an abrupt transient loss in the cone outer segment tip (COST) reflection followed by its return that is axially displaced anteriorly. Using this signature, we measured the temporal and spatial properties of shedding events in three normal subjects. Average duration of the shedding event was 8.8 ± 13.4 minutes, and average length loss of the OS was 2.1 μm (7.0% of OS length). Prevalence of cone shedding was highest in the morning (14.3%) followed by the afternoon (5.7%) and evening (4.0%), with load distributed across the imaged patch. To the best of our knowledge these are the first images of photoreceptor disc shedding in the living retina. PMID:27895995

  11. Determination of cup-to-disc ratio of optical nerve head for diagnosis of glaucoma on stereo retinal fundus image pairs

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Nakagawa, Toshiaki; Sawada, Akira; Hatanaka, Yuji; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2009-02-01

    A large cup-to-disc (C/D) ratio, which is the ratio of the diameter of the depression (cup) to that of the optical nerve head (ONH, disc), can be one of the important signs for diagnosis of glaucoma. Eighty eyes, including 25 eyes with the signs of glaucoma, were imaged by a stereo retinal fundus camera. An ophthalmologist provided the outlines of cup and disc on a regular monitor and on the stereo display. The depth image of the ONH was created by determining the corresponding pixels in a pair of images based on the correlation coefficient in localized regions. The areas of the disc and cup were determined by use of the red component in one of the color images and by use of the depth image, respectively. The C/D ratio was determined based on the largest vertical lengths in the cup and disc areas, which was then compared with that by the ophthalmologist. The disc areas determined by the computerized method agreed relatively well with those determined by the ophthalmologist, whereas the agreement for the cup areas was somewhat lower. When C/D ratios were employed for distinction between the glaucomatous and non-glaucomatous eyes, the area under the receiver operating characteristic curve (AUC) was 0.83. The computerized analysis of ONH can be useful for diagnosis of glaucoma.

  12. The golden ratio of nasal width to nasal bone length.

    PubMed

    Goynumer, G; Yayla, M; Durukan, B; Wetherilt, L

    2011-01-01

    To calculate the ratio of fetal nasal width over nasal bone length at 14-39 weeks' gestation in Caucasian women. Fetal nasal bone length and nasal width at 14-39 weeks' gestation were measured in 532 normal fetuses. The mean and standard deviations of fetal nasal bone length, nasal width and their ratio to one another were calculated in normal fetuses according to the gestational age to establish normal values. A positive and linear correlation was detected between the nasal bone length and the gestational week, as between the nasal width and the gestational week. No linear growth pattern was found between the gestational week and the ratio of nasal width to nasal bone length, nearly equal to phi, throughout gestation. The ratio of nasal width to nasal bone length, approximately equal to phi, can be calculated at 14-38 weeks' gestation. This might be useful in evaluating fetal abnormalities.

  13. Nasal polyps

    MedlinePlus

    ... get rid of nasal polyps. Nasal steroid sprays shrink polyps. They help clear blocked nasal passages and ... is stopped. Corticosteroid pills or liquid may also shrink polyps, and can reduce swelling and nasal congestion. ...

  14. Image processing based automatic diagnosis of glaucoma using wavelet features of segmented optic disc from fundus image.

    PubMed

    Singh, Anushikha; Dutta, Malay Kishore; ParthaSarathi, M; Uher, Vaclav; Burget, Radim

    2016-02-01

    Glaucoma is a disease of the retina which is one of the most common causes of permanent blindness worldwide. This paper presents an automatic image processing based method for glaucoma diagnosis from the digital fundus image. In this paper wavelet feature extraction has been followed by optimized genetic feature selection combined with several learning algorithms and various parameter settings. Unlike the existing research works where the features are considered from the complete fundus or a sub image of the fundus, this work is based on feature extraction from the segmented and blood vessel removed optic disc to improve the accuracy of identification. The experimental results presented in this paper indicate that the wavelet features of the segmented optic disc image are clinically more significant in comparison to features of the whole or sub fundus image in the detection of glaucoma from fundus image. Accuracy of glaucoma identification achieved in this work is 94.7% and a comparison with existing methods of glaucoma detection from fundus image indicates that the proposed approach has improved accuracy of classification. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Comparison of Nasal Acceleration and Nasalance across Vowels

    ERIC Educational Resources Information Center

    Thorp, Elias B.; Virnik, Boris T.; Stepp, Cara E.

    2013-01-01

    Purpose: The purpose of this study was to determine the performance of normalized nasal acceleration (NNA) relative to nasalance as estimates of nasalized versus nonnasalized vowel and sentence productions. Method: Participants were 18 healthy speakers of American English. NNA was measured using a custom sensor, and nasalance was measured using…

  16. DZ Chamaeleontis: a bona fide photoevaporating disc

    NASA Astrophysics Data System (ADS)

    Canovas, H.; Montesinos, B.; Schreiber, M. R.; Cieza, L. A.; Eiroa, C.; Meeus, G.; de Boer, J.; Ménard, F.; Wahhaj, Z.; Riviere-Marichalar, P.; Olofsson, J.; Garufi, A.; Rebollido, I.; van Holstein, R. G.; Caceres, C.; Hardy, A.; Villaver, E.

    2018-02-01

    Context. DZ Cha is a weak-lined T Tauri star (WTTS) surrounded by a bright protoplanetary disc with evidence of inner disc clearing. Its narrow Hα line and infrared spectral energy distribution suggest that DZ Cha may be a photoevaporating disc. Aims: We aim to analyse the DZ Cha star + disc system to identify the mechanism driving the evolution of this object. Methods: We have analysed three epochs of high resolution optical spectroscopy, photometry from the UV up to the sub-mm regime, infrared spectroscopy, and J-band imaging polarimetry observations of DZ Cha. Results: Combining our analysis with previous studies we find no signatures of accretion in the Hα line profile in nine epochs covering a time baseline of 20 yr. The optical spectra are dominated by chromospheric emission lines, but they also show emission from the forbidden lines [SII] 4068 and [OI] 6300Å that indicate a disc outflow. The polarized images reveal a dust depleted cavity of 7 au in radius and two spiral-like features, and we derive a disc dust mass limit of Mdust< 3 MEarth from the sub-mm photometry. No stellar (M⋆> 80 MJup) companions are detected down to 0.̋07 ( 8 au, projected). Conclusions: The negligible accretion rate, small cavity, and forbidden line emission strongly suggests that DZ Cha is currently at the initial stages of disc clearing by photoevaporation. At this point the inner disc has drained and the inner wall of the truncated outer disc is directly exposed to the stellar radiation. We argue that other mechanisms like planet formation or binarity cannot explain the observed properties of DZ Cha. The scarcity of objects like this one is in line with the dispersal timescale (≲105 yr) predicted by this theory. DZ Cha is therefore an ideal target to study the initial stages of photoevaporation. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere under ESO programme 097.C-0536. Based on data obtained from the

  17. Lenticular astigmatism in tilted disc syndrome.

    PubMed

    Gündüz, Abuzer; Evereklioglu, Cem; Er, Hamdi; Hepşen, Ibrahim F

    2002-10-01

    To evaluate whether an abnormal optic disc shape in patients with tilted disc syndrome (TDS) is associated with an abnormal configuration of the crystalline lens measured as lenticular astigmatism. Department of Ophthalmology, Inönü University Medical Faculty, Turgut Ozal Medical Center, Malatya, Turkey. This cross-sectional masked case-control study comprised 32 eyes of 32 patients with established TDS (13 men, 19 women; mean age 21.31 years +/- 7.05 [SD]) and 20 age- and sex-matched healthy control subjects (8 men, 12 women; mean age 22.65 +/- 7.11 years) with a comparable amount of myopic astigmatism (spherical equivalent) without TDS. The optic disc was morphometrically analyzed by planimetric evaluation of optic disc photographs. The total refractive and keratometric corneal astigmatism was obtained, and lenticular astigmatism was calculated by vector analysis. The Mann-Whitney U test was used for statistical analysis; 1 eye of each patient was evaluated in both groups. A P value less than 0.05 was considered statistically significant. The mean spherical equivalent refraction was comparable in TDS patients (-4.73 +/- 1.12 diopters [D]) and controls (-4.28 +/- 1.29 D) (P =.210). The mean total astigmatism was higher in TDS patients (-2.96 +/- 1.04 D) than in the controls (-2.51 +/- 1.09 D), but the difference was not significant (P =.151). The mean corneal astigmatism was comparable in TDS patients (-2.07 +/- 0.83 D) and controls (-2.28 +/- 0.87 D) (P =.454), but the calculated mean lenticular astigmatism was significantly higher in TDS patients (-1.31 +/- 0.98 D and -0.20 +/- 0.35 D, respectively) (P <.001). Twenty-nine of 32 TDS patients (90.6%) had lenticular astigmatism; in 16 (50%), it was greater than -1.00 D. Lenticular astigmatism was present in 7 controls (35%); in 2 (10%), it was greater than -1.00 D. The mean keratometry was significantly higher in TDS patients (43.84 +/- 1.06 D) than in the controls (42.75 +/- 1.45 D) (P =.011). Clinically

  18. Nasal deposition of ciclesonide nasal aerosol and mometasone aqueous nasal spray in allergic rhinitis patients.

    PubMed

    Emanuel, Ivor A; Blaiss, Michael S; Meltzer, Eli O; Evans, Philip; Connor, Alyson

    2014-01-01

    Sensory attributes of intranasal corticosteroids, such as rundown to the back of the throat, may influence patient treatment preferences. This study compares the nasal deposition and nasal retention of a radiolabeled solution of ciclesonide nasal aerosol (CIC-hydrofluoroalkane [HFA]) with a radiolabeled suspension of mometasone furoate monohydrate aqueous nasal spray (MFNS) in subjects with either perennial allergic rhinitis (AR) or seasonal AR. In this open-label, single-dose, randomized, crossover scintigraphy study, 14 subjects with symptomatic AR received a single dose of radiolabeled 74-μg CIC-HFA (37 μg/spray, 1 spray/each nostril) via a nasal metered-dose inhaler or a single dose of radiolabeled 200-μg MFNS (50 μg/spray, 2 sprays/each nostril), with a minimum 5-day washout period between treatments. Initial deposition (2 minutes postdose) of radiolabeled CIC-HFA and MFNS in the nasal cavity, nasopharynx, and on nasal wipes, and retention of radioactivity in the nasal cavity and nasal run-out on nasal wipes at 2, 4, 6, 8, and 10 minutes postdose were quantified with scintigraphy. At 2 and 10 minutes postdose, deposition of radiolabeled CIC-HFA was significantly higher in the nasal cavity versus radiolabeled MFNS (99.42% versus 86.50% at 2 minutes, p = 0.0046; and 81.10% versus 54.31% at 10 minutes, p < 0.0001, respectively; p values unadjusted for multiplicity). Deposition of radioactivity on nasal wipes was significantly higher with MFNS versus CIC-HFA at all five time points, and posterior losses of radiolabeled formulation were significantly higher with MFNS at 6, 8, and 10 minutes postdose. In this scintigraphic study, significantly higher nasal deposition and retention of radiolabeled aerosol CIC-HFA were observed versus radiolabeled aqueous MFNS in subjects with AR.

  19. Long term multiwavelength studies of the corona/disc connection in AGN

    NASA Astrophysics Data System (ADS)

    Buisson, D.; Lohfink, A.; Alston, W.; Fabian, A.; Gallo, L.; Kara, E.; Zoghbi, A.; Wilkins, D.; Miller, J.; Cackett, E.

    2017-10-01

    One way of increasing our understanding of AGN is determining the nature of the connection between the optical/UV emitting accretion disc and the X-ray emitting corona. Studies of variability in these two bands are a key tool for gaining insight into the processes involved. We will present results from a sample of long-term AGN monitoring campaigns in the optical, UV and X-ray with Swift. In particular, we will explore UV/optical-X-ray correlations and associated time lags. We will compare these measurements and the UV/optical RMS spectra with theoretical reprocessing models and confront recent claims of the observed lags being longer than those which are expected for a standard thin disc. Additionally, a new Swift monitoring campaign of the z=2 quasar PG 1247+267 allows us to probe the shorter wavelengths at the peak of the accretion disc spectrum, providing information on the region of the disc closest to the black hole. However, not all AGN show such correlations, including IRAS 13224-3809, the subject of a recent 1.5 Ms XMM observation. Using this and other examples, we will explore the possible reasons for the lack of observed correlation.

  20. Lights and shadows: multi-wavelength analysis of young stellar objects and their protoplanetary discs

    NASA Astrophysics Data System (ADS)

    Rigon, Laura

    2016-03-01

    Stars form from the collapse of molecular clouds and evolve in an environment rich in gas and dust before becoming Main Sequence stars. During this phase, characterised by the presence of a protoplanetary disc, stars manifest changes in the structure and luminosity. This thesis performs a multi-wavelength analysis, from optical to mm range, on a sample of young stars (YSOs), mainly Classical T Tauri (CTTS). The purpose is to study optical and infrared variability and its relation with the protoplanetary disc. Longer wavelength, in the mm range, are used instead to investigate the evolution of the disc, in terms of dust growth. In optical, an F-test on a sample of 39 CTTS reveals that 67% of the stars are variable. The variability, quantified through pooled sigma, is visible both in magnitude amplitudes and changes over time. Time series analysis applied on the more variable stars finds the presence of quasi periodicity, with periods longer than two weeks, interpreted either as eclipsing material in the disc happening on a non-regular basis, or as a consequence of star-disc interaction via magnetic field lines. The variability of YSOs is confirmed also in infrared, even if with lower amplitude. No strong correlations are found between optical and infrared variability, which implies a different cause or a time shift in the two events. By using a toy model to explore their origin, I find that infrared variations are likely to stem from emissions in the inner disc. The evolution of discs in terms of dust growth is confirmed in most discs by the analysis of the slope of the spectral energy distribution (SED), after correcting for wind emission and optical depth effects. However, the comparison with a radiative transfer model highlights that a number of disc parameters, in particular disc masses and temperature, dust size distribution and composition, can also affect the slope of the SED.

  1. Optical coherence tomography in papilledema and pseudopapilledema with and without optic nerve head drusen

    PubMed Central

    Bassi, Shikha Talwar; Mohana, Kuppuswamy Parthasarthy

    2014-01-01

    Aim: To compare the spectral domain optical coherence tomography (SD-OCT) findings of the optic disc and the peripapillary retina of patients with a true papilledema and pseudopapilledema with and without optic nerve head drusen (ONHD). Study Design: Retrospective Case Control Study. Subjects and Methods: Peripapillary retinal nerve fiber layer (PPRNFL) thickness as depicted by SD-OCT of 94 eyes of 66 patients with papilledema (30 eyes), pseudopapiledema (31 eyes), and normal controls (33 eyes) was analyzed. The mean RNFL thickness, total retinal thickness (TRT) at a superior and inferior edge of the disc and the quadrant wise topography of increased RNFL were compared in all three groups. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) were calculated for all the parameters. Results: The median RNFL thickness was 185.4 (129.5–349.3 μm), 122.3 (109–156.3 μm) and 91.62 ± 7 μm in papilledema, pseudopapilledema, and controls, respectively. Papilledema group had thicker PPRNFL in all quadrants except temporal quadrant. TRT was thicker in papilledema and pseudopapilledema compared to controls. ONHD could be directly visualized as high reflective clumps in the sub-retinal space or the RNFL in 30 eyes. Increased RNFL thickness in all four quadrants was noted 43.3% in papilledema and 9.7% in pseudopapilledema. Normal RNFL thickness in all four quadrants was noted in 0% in papilledema and 32.3% in pseudopapilledema. Nasal RNFL had the highest AROC (0.792) indicating high diagnostic ability to differentiate papilledema from pseudopapilledema. Conclusion: SD-OCT can be used as a tool to differentiate between papilledema and pseudopapilledema. PMID:25579359

  2. Ultra Compact Optical Pickup with Integrated Optical System

    NASA Astrophysics Data System (ADS)

    Nakata, Hideki; Nagata, Takayuki; Tomita, Hironori

    2006-08-01

    Smaller and thinner optical pickups are needed for portable audio-visual (AV) products and notebook personal computers (PCs). We have newly developed an ultra compact recordable optical pickup for Mini Disc (MD) that measures less than 4 mm from the disc surface to the bottom of the optical pickup, making the optical system markedly compact. We have integrated all the optical components into an objective lens actuator moving unit, while fully satisfying recording and playback performance requirements. In this paper, we propose an ultra compact optical pickup applicable to portable MD recorders.

  3. Objective Measure of Nasal Air Emission Using Nasal Accelerometry

    ERIC Educational Resources Information Center

    Cler, Meredith J.; Lien, Yu-An, S.; Braden, Maia N.; Mittleman, Talia; Downing, Kerri; Stepp, Cara, E.

    2016-01-01

    Purpose: This article describes the development and initial validation of an objective measure of nasal air emission (NAE) using nasal accelerometry. Method: Nasal acceleration and nasal airflow signals were simultaneously recorded while an expert speech language pathologist modeled NAEs at a variety of severity levels. In addition, microphone and…

  4. Evaluation of polyvinylidene fluoride nasal sensor to assess deviated nasal septum in comparision with peak nasal inspiratory flow measurements.

    PubMed

    Manjunatha, Roopa G; Rajanna, K; Mahapatra, D Roy; Prakash, Surya

    2014-01-01

    Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.

  5. Influence of corneal power on circumpapillary retinal nerve fiber layer and optic nerve head measurements by spectral-domain optical coherence tomography.

    PubMed

    Hirasawa, Kazunori; Shoji, Nobuyuki

    2017-01-01

    To evaluate the influence of corneal power on circumpapillary retinal nerve fiber layer (cpRNFL) and optic nerve head (ONH) measurements by spectral-domain optical coherence tomography (SD-OCT). Twenty-five eyes of 25 healthy participants (mean age 23.6±3.6y) were imaged by SD-OCT using horizontal raster scans. Disposable soft contact lenses of different powers (from -11 to +5 diopters including 0 diopter) were worn to induce 2-diopter changes in corneal power. Differences in the cpRNFL and ONH measurements per diopter of change in corneal power were analyzed. As corneal power increased by 1 diopter, total and quadrant cpRNFL thicknesses, except for the nasal sector, decreased by --0.19 to -0.32 µm ( P <0.01). Furthermore, the disc, cup, and rim areas decreased by -0.017, -0.007, and -0.015 mm 2 , respectively ( P <0.001); the cup and rim volumes decreased by -0.0013 and -0.006 mm 3 , respectively ( P <0.01); and the vertical and horizontal disc diameters decreased by -0.006 and -0.007 mm, respectively ( P <0.001). For more precise OCT imaging, the ocular magnification should be corrected by considering both the axial length and corneal power. However, the effect of corneal power changes on cpRNFL thickness and ONH topography are small when compare with those of the axial length.

  6. Optic nerve compression as a late complication of a hydrogel explant with silicone encircling band.

    PubMed

    Crama, Niels; Kluijtmans, Leo; Klevering, B Jeroen

    2018-06-01

    To present a complication of compressive optic neuropathy caused by a swollen hydrogel explant and posteriorly displaced silicone encircling band. A 72-year-old female patient presented with progressive visual loss and a tilted optic disc. Her medical history included a retinal detachment in 1993 that was treated with a hydrogel explant under a solid silicone encircling band. Visual acuity had decreased from 6/10 to 6/20 and perimetry showed a scotoma in the temporal superior quadrant. On Magnetic Resonance Imaging (MRI), compression of the optic nerve by a displaced silicone encircling band inferior nasally in combination with a swollen episcleral hydrogel explant was observed. Surgical removal of the hydrogel explant and silicone encircling band was uneventful and resulted in improvement of visual acuity and visual field loss. This is the first report on compressive optic neuropathy caused by swelling of a hydrogel explant resulting in a dislocated silicone encircling band. The loss of visual function resolved upon removal of the explant and encircling band.

  7. Incidence and evolution of subretinal precipitates in optic disc pit maculopathy.

    PubMed

    Chatziralli, Irini; Theodossiadis, George; Brouzas, Dimitrios; Theodossiadis, Panagiotis

    2017-06-26

    To study the evolution of subretinal precipitates coexistent with optic disc pit (ODP) maculopathy from their appearance at baseline examination until their absorption after successful treatment. Participants in this retrospective, multicenter study were 42 patients with ODP maculopathy, in whom complete ocular examination was performed, including visual acuity (VA) measurement, slit-lamp examination, color or red-free fundus photography, and optical coherence tomography at baseline after surgical treatment. Out of 42 cases, 17 (40.5%) cases of ODP maculopathy, which were examined between 2002 and 2015, were found to have subretinal precipitates associated with multilayer fluid accumulation at baseline. Precipitates were located at the outer part of the photoreceptor layer and remained for 3-6 months after successful treatment and absorption of subretinal fluid. The mean VA was 0.99 ± 0.21 logMAR at baseline and improved to 0.54 ± 0.25 logMAR at the final examination. Macular precipitates in association with signs of disease chronicity, such as multilayer fluid accumulation, became evident at baseline examination. Precipitates' disappearance in 15 out of 17 cases coincided with the absorption of subretinal fluid. The relative low VA at baseline probably could be attributed to the chronicity of the disease.

  8. Atomic gas in debris discs

    NASA Astrophysics Data System (ADS)

    Hales, Antonio S.; Barlow, M. J.; Crawford, I. A.; Casassus, S.

    2017-04-01

    We have conducted a search for optical circumstellar absorption lines in the spectra of 16 debris disc host stars. None of the stars in our sample showed signs of emission line activity in either Hα, Ca II or Na I, confirming their more evolved nature. Four stars were found to exhibit narrow absorption features near the cores of the photospheric Ca II and Na I D lines (when Na I D data were available). We analyse the characteristics of these spectral features to determine whether they are of circumstellar or interstellar origins. The strongest evidence for circumstellar gas is seen in the spectrum of HD 110058, which is known to host a debris disc observed close to edge-on. This is consistent with a recent ALMA detection of molecular gas in this debris disc, which shows many similarities to the β Pictoris system.

  9. Molecular mechanisms of optic axon guidance

    NASA Astrophysics Data System (ADS)

    Inatani, Masaru

    2005-12-01

    Axon guidance is one of the critical processes during vertebrate central nervous system (CNS) development. The optic nerve, which contains the axons of retinal ganglion cells, has been used as a powerful model to elucidate some of the mechanisms underlying axon guidance because it is easily manipulated experimentally, and its function is well understood. Recent molecular biology studies have revealed that numerous guidance molecules control the development of the visual pathway. This review introduces the molecular mechanisms involved in each critical step during optic axon guidance. Axonal projections to the optic disc are thought to depend on adhesion molecules and inhibitory extracellular matrices such as chondroitin sulfate. The formation of the head of the optic nerve and the optic chiasm require ligand-receptor interactions between netrin-1 and the deleted in colorectal cancer receptor, and Slit proteins and Robo receptors, respectively. The gradient distributions of ephrin ligands and Eph receptors are essential for correct ipsilateral projections at the optic chiasm and the topographic mapping of axons in the superior colliculus/optic tectum. The precise gradient is regulated by transcription factors determining the retinal dorso-ventral and nasal-temporal polarities. Moreover, the axon guidance activities by Slit and semaphorin 5A require the existence of heparan sulfate, which binds to numerous guidance molecules. Recent discoveries about the molecular mechanisms underlying optic nerve guidance will facilitate progress in CNS developmental biology and axon-regeneration therapy.

  10. Progress in Electron Beam Mastering of 100 Gbit/inch2 Density Disc

    NASA Astrophysics Data System (ADS)

    Takeda, Minoru; Furuki, Motohiro; Yamamoto, Masanobu; Shinoda, Masataka; Saito, Kimihiro; Aki, Yuichi; Kawase, Hiroshi; Koizumi, Mitsuru; Miyokawa, Toshiaki; Mutou, Masao; Handa, Nobuo

    2004-07-01

    We developed an electron beam recorder (EBR) capable of recording master discs under atmospheric conditions using a novel differential pumping head. Using the EBR and optimized fabrication process for Si-etched discs with reactive ion etching (RIE), a bottom signal jitter of 9.6% was obtained from a 36 Gbit/inch2 density disc, readout using a near-field optical pickup with an effective numerical aperture (NA) of 1.85 and a wavelength of 405 nm. We also obtained the eye patterns from a 70 Gbit/inch2 density disc readout using an optical pickup with a 2.05 NA and the same wavelength, and showed almost the same modulation ratio as the simulation value. Moreover, the capability of producing pit patterns corresponding to a 104 Gbit/inch2 density is demonstrated.

  11. Similarity and Enhancement: Nasality from Moroccan Arabic Pharyngeals and Nasals

    ERIC Educational Resources Information Center

    Zellou, Georgia Eve

    2012-01-01

    Experimental studies of the articulation, acoustics, and perception of nasal and pharyngeal consonants and adjacent vowels were conducted to investigate nasality in Moroccan Arabic (MA). The status of nasality in MA is described as coarticulatorily complex, where two phoneme types (pharyngeal segments and nasal segments) yield similar…

  12. [Vitrectomy and gas-fluid exchange for the treatment of serous macular detachment due to optic disc pit: long-term evaluation].

    PubMed

    Moreira Neto, Carlos Augusto; Moreira Junior, Carlos Augusto

    2013-01-01

    To evaluate 5 patients with serous macular detachment due to optic disc pit that were submitted to pars plana vitrectomy and were followed for at least 7 years. Patients were submitted to pars plana vitrectomy, posterior hyaloid removal, autologous serum injection and gas-fluid exchange, without laser photocoagulation, and were evaluated pre and post-operatively with visual acuity and Amsler grid testing, retinography, and recently, with autofluorescence imaging and high resolution OCT. All 5 eyes improved visual acuity significantly following the surgical procedure maintaining good vision throughout the follow-up period. Mean pre-operative visual acuity was 20/400 and final visual acuity was 20/27 with a mean follow-up time of 13.6 years. No recurrences of serous detachments were observed. OCT examinations demonstrated an attached retina up to the margin of the pit. Serous macular detachments due to optic disc pits were adequately treated with pars plana vitrectomy and gas fluid exchange, without the need for laser photocoagulation, maintaining excellent visual results for a long period of time.

  13. Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma.

    PubMed

    Cordeiro, Daniela Valença; Lima, Verônica Castro; Castro, Dinorah P; Castro, Leonardo C; Pacheco, Maria Angélica; Lee, Jae Min; Dimantas, Marcelo I; Prata, Tiago Santos

    2011-01-01

    To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect

  14. Saline nasal washes

    MedlinePlus

    ... nasal wash helps flush pollen, dust, and other debris from your nasal passages. It also helps remove excess mucus (snot) and adds moisture. Your nasal passages are open spaces behind your nose. Air passes through your nasal ...

  15. Genetic Variants Associated with Optic Nerve Vertical Cup-to-Disc Ratio Are Risk Factors for Primary Open Angle Glaucoma in a US Caucasian Population

    PubMed Central

    Fan, Bao Jian; Wang, Dan Yi; Pasquale, Louis R.; Haines, Jonathan L.

    2011-01-01

    Purpose. Genetically complex disorders, such as primary open angle glaucoma (POAG), may include highly heritable quantitative traits as part of the overall phenotype, and mapping genes influencing the related quantitative traits may effectively identify genetic risk factors predisposing to the complex disease. Recent studies have identified SNPs associated with optic nerve area and vertical cup-to-disc ratio (VCDR). The purpose of this study was to evaluate the association between these SNPs and POAG in a US Caucasian case-control sample. Methods. Five SNPs previously associated with optic disc area, or VCDR, were genotyped in 539 POAG cases and 336 controls. Genotype data were analyzed for single SNP associations and SNP interactions with VCDR and POAG. Results. SNPs associated with VCDR rs1063192 (CDKN2B) and rs10483727 (SIX1/SIX6) were also associated with POAG (P = 0.0006 and P = 0.0043 for rs1063192 and rs10483727, respectively). rs1063192, associated with smaller VCDR, had a protective effect (odds ratio [OR] = 0.73; 95% confidence interval [CI], 0.58–0.90), whereas rs10483727, associated with larger VCDR, increased POAG risk (OR = 1.33; 95% CI, 1.08–1.65). POAG risk associated with increased VCDR was significantly influenced by the C allele of rs1900004 (ATOH7), associated with increased optic nerve area (P-interaction = 0.025; OR = 1.89; 95% CI, 1.22–2.94). Conclusions. Genetic variants influencing VCDR are associated with POAG in a US Caucasian population. Variants associated with optic nerve area are not independently associated with disease but can influence the effects of VCDR variants suggesting that increased optic disc area can significantly contribute to POAG risk when coupled with risk factors controlling VCDR. PMID:21398277

  16. Disc resonator gyroscope fabrication process requiring no bonding alignment

    NASA Technical Reports Server (NTRS)

    Shcheglov, Kirill V. (Inventor)

    2010-01-01

    A method of fabricating a resonant vibratory sensor, such as a disc resonator gyro. A silicon baseplate wafer for a disc resonator gyro is provided with one or more locating marks. The disc resonator gyro is fabricated by bonding a blank resonator wafer, such as an SOI wafer, to the fabricated baseplate, and fabricating the resonator structure according to a pattern based at least in part upon the location of the at least one locating mark of the fabricated baseplate. MEMS-based processing is used for the fabrication processing. In some embodiments, the locating mark is visualized using optical and/or infrared viewing methods. A disc resonator gyroscope manufactured according to these methods is described.

  17. [Clinical analysis of nasal resistance and pulmonary function testing in patients with chronic nasal-sinusitis and nasal polyps].

    PubMed

    Liao, Hua; Shen, Ying; Wang, Pengjun

    2015-05-01

    To study the pulmonary function and nasal resistance characteristics of patients with chronic nose-sinusitis and nasal polyps (CRSwNP), to explore the evaluation role of nasal resistance in nasal ventilation function and the effect of endoscopic sinus surgery on pulmonary function in patients with CRSwNP. Fifty CRSwNP patients that met the study criteria were selected . The patients were performed endoscopic surgeries according to Messerklinger surgical procedures under general anesthesia. Extent of surgery was based on preoperative CT showing the range of the lesion of disease and endoscopic findings. Perioperative treatments contained intranasal corticosteroids, cephalosporin or penicillin antibiotics, nasal irrigation and other treatments. Main outcome measures included visual analog scale (VAS), endoscopic Lind-Kennedy scores, nasal resistence, pulmonary function in patientsone week before and after surgery, three months and six months after surgery. Pulmonary function includes forced expiratory volume in one second (FEV1), forced vital capacity FEV1/FVC and peak expiratory flow (PEF). The study found that there were significantly positive correlations among VAS score, Lund-Kennedy score and nasal resistance (P < 0.05) in CRSwNP patients, but there is a significantly negative correlation between VAS score, Lund-Kennedy score, nasal resistance and pulmonary function indexes of FEV1, FVC and PEF (P < 0.05). The VAS score, Lund-Kennedy score and nasal resistance values of CRSwNP patients were decreased significantly after comprehensive treatments with nasal endoscopic operation as the major one, the difference was statistically different (P < 0.05). And the pulmonary function indexs (FEV1, FVC, PEF) were significantly increased after surgery in CRSwNP patients. The nasal resistance can objectively and reliably reflect the degree of nasal congestion and the recovery of nasal function in CRSwNP patients after endoscopic sinus surgery. The detection method of nasal

  18. Mean curvature and texture constrained composite weighted random walk algorithm for optic disc segmentation towards glaucoma screening.

    PubMed

    Panda, Rashmi; Puhan, N B; Panda, Ganapati

    2018-02-01

    Accurate optic disc (OD) segmentation is an important step in obtaining cup-to-disc ratio-based glaucoma screening using fundus imaging. It is a challenging task because of the subtle OD boundary, blood vessel occlusion and intensity inhomogeneity. In this Letter, the authors propose an improved version of the random walk algorithm for OD segmentation to tackle such challenges. The algorithm incorporates the mean curvature and Gabor texture energy features to define the new composite weight function to compute the edge weights. Unlike the deformable model-based OD segmentation techniques, the proposed algorithm remains unaffected by curve initialisation and local energy minima problem. The effectiveness of the proposed method is verified with DRIVE, DIARETDB1, DRISHTI-GS and MESSIDOR database images using the performance measures such as mean absolute distance, overlapping ratio, dice coefficient, sensitivity, specificity and precision. The obtained OD segmentation results and quantitative performance measures show robustness and superiority of the proposed algorithm in handling the complex challenges in OD segmentation.

  19. Assessment of nasalance and nasality in patients with a repaired cleft palate.

    PubMed

    Sinko, Klaus; Gruber, Maike; Jagsch, Reinhold; Roesner, Imme; Baumann, Arnulf; Wutzl, Arno; Denk-Linnert, Doris-Maria

    2017-07-01

    In patients with a repaired cleft palate, nasality is typically diagnosed by speech language pathologists. In addition, there are various instruments to objectively diagnose nasalance. To explore the potential of nasalance measurements after cleft palate repair by NasalView ® , we correlated perceptual nasality and instrumentally measured nasalance of eight speech items and determined the relationship between sensitivity and specificity of the nasalance measures by receiver-operating characteristics (ROC) analyses and AUC (area under the curve) computation for each single test item and specific item groups. We recruited patients with a primarily repaired cleft palate receiving speech therapy during follow-up. During a single day visit, perceptive and instrumental assessments were obtained in 36 patients and analyzed. The individual perceptual nasality was assigned to one of four categories; the corresponding instrumental nasalance measures for the eight specific speech items were expressed on a metric scale (1-100). With reference to the perceptual diagnoses, we observed 3 nasal and one oral test item with high sensitivity. However, the specificity of the nasality indicating measures was rather low. The four best speech items with the highest sensitivity provided scores ranging from 96.43 to 100%, while the averaged sensitivity of all eight items was below 90%. We conclude that perceptive evaluation of nasality remains state of the art. For clinical follow-up, instrumental nasalance assessment can objectively document subtle changes by analysis of four speech items only. Further studies are warranted to determine the applicability of instrumental nasalance measures in the clinical routine, using discriminative items only.

  20. Optical excess of dim isolated neutron stars

    NASA Astrophysics Data System (ADS)

    Ertan, Ü.; Çalışkan, Ş.; Alpar, M. A.

    2017-09-01

    The optical excess in the spectra of dim isolated neutron stars (XDINs) is a significant fraction of their rotational energy loss rate. This is strikingly different from the situation in isolated radio pulsars. We investigate this problem in the framework of the fallback disc model. The optical spectra can be powered by magnetic stresses on the innermost disc matter, as the energy dissipated is emitted as blackbody radiation mainly from the inner rim of the disc. In the fallback disc model, XDINs are the sources evolving in the propeller phase with similar torque mechanisms. In this model, the ratio of the total magnetic work that heats up the inner disc matter is expected to be similar for different XDINs. Optical luminosities that are calculated consistently with the optical spectra and the theoretical constraints on the inner disc radii give very similar ratios of the optical luminosity to the rotational energy loss rate for all these sources. These ratios indicate that a significant fraction of the magnetic torque heats up the disc matter while the remaining fraction expels disc matter from the system. For XDINs, the contribution of heating by X-ray irradiation to the optical luminosity is negligible in comparison with the magnetic heating. The correlation we expect between the optical luminosities and the rotational energy loss rates of XDINs can be a property of the systems with low X-ray luminosities, in particular those in the propeller phase.

  1. Olfactory Neuroblastoma: A Rare Cause of External Ophthalmoplegia, Proptosis and Compressive Optic Neuropathy.

    PubMed

    Kartı, Ömer; Zengin, Mehmet Özgür; Çelik, Ozan; Tokat, Taşkın; Küsbeci, Tuncay

    2018-04-01

    Olfactory neuroblastoma (ONB), which is a neuroectodermal tumor of the nasal cavity, is a rare and locally aggressive malignancy that may invade the orbit via local destruction. In this study, we report a patient with proptosis, external ophthalmoplegia, and compressive optic neuropathy caused by ONB. A detailed clinical examination including ocular imaging and histopathological studies were performed. The 62-year-old female patient presented to our clinic with complaints of proptosis and visual deterioration in the left eye. Her complaints started 2 months prior to admission. Visual acuity in the left eye was counting fingers from 2 meters. There was relative afferent pupillary defect. She had 6 mm of proptosis and limitation of motility. Fundus examination was normal in the right eye, but there was a hyperemic disc, and increased vascular tortuosity and dilation of the retinal veins in the left eye. Computerized tomography and magnetic resonance imaging of the brain and orbits demonstrated a large heterogeneous mass in the left superior nasal cavity with extensions into the ethmoidal sinuses as well as into the left orbit, compressing the medial rectus muscle and optic nerve. Endoscopic biopsy of the lesion was consistent with an ONB (Hyams' grade III). Orbital invasion may occur in patients with ONB. Therefore, it is important to be aware of this malignancy because some patients present with ophthalmic signs such as external ophthalmoplegia, proptosis, or compressive optic neuropathy.

  2. Observation of neovascularization of the disc associated with proliferative diabetic retinopathy using OCT angiography.

    PubMed

    Akiyama, Hideo; Li, Danjie; Shimoda, Yukitoshi; Matsumoto, Hidetaka; Kishi, Shoji

    2018-05-01

    To describe the relationship between the vitreous and the neovascularization of the disc (NVD) using swept source optical coherence tomography (SS-OCT) and OCT angiography (OCTA). Retrospective. We examined 17 eyes of 11 consecutive patients diagnosed as NVD associated with proliferative diabetic retinopathy (PDR). The location of the NVD feeder or collector vessels were examined by using RTVue XR Avanti. To determine the condition of the posterior vitreous detachment (PVD) and the proliferative tissue of the NVD, we performed 12 mm horizontal and vertical scans through the disc using SS-OCT. OCT images of all 17 cases indicated there was no PVD on the optic disc. OCTA showed that the locations of the newly formed vessels from the optic disc were overwhelmingly outside the physiological cupping (95%). No cases exhibited formation of neovascularization inside the physiological cupping. OCT images revealed all 17 eyes had proliferative tissues located under the posterior wall of the vitreous, with 12 out of 17 eyes exhibiting additional invasion of the proliferative tissue into the vitreous through the posterior wall. Epiretinal membrane or a thickened posterior wall of the vitreous was present in 10 out of the 17 eyes. NVD associated with PDR arises from outside the physiological cupping and grows along the posterior wall of the vitreous. The absence of PVD on the optic disc is essential to the growth of NVD.

  3. Birth weight and optic nerve head parameters.

    PubMed

    Samarawickrama, Chameen; Huynh, Son C; Liew, Gerald; Burlutsky, George; Mitchell, Paul

    2009-06-01

    To assess the relationship of birth weight, birth length, and head circumference as proxy markers of intrauterine growth, cup/disc ratio, and other optic disc parameters measured using optical coherence tomography (OCT). Population-based cross sectional analysis. The Sydney Childhood Eye Study examined 2353 primarily 12-year-old children from 21 randomly selected secondary schools during 2003 to 2005. Of 2353 children examined, 2134 (90.7%) had OCT scans (Zeiss Stratus OCT, Carl Zeiss Meditec, Dublin, CA) and are included in this study. The "fast" optic disc scan protocol was used. Birth weight, birth length, and head circumference were ascertained from health records. Height and weight were measured using standardized protocols, body mass index (BMI) was defined as weight (kilograms)/ height squared (meters), and sociodemographic information was collected in a questionnaire completed by parents. Low birth weight was defined as birth weight optic disc and optic cup diameters, and cup/disc ratio. Children of low birth weight had decreased vertical disc diameter, increased cup diameter, and increased cup/disc ratio by 30 microm (P = 0.009), 44 microm (P = 0.004), and 0.03 (P<0.0001), respectively. After adjusting for age, gender, ethnicity, height, axial length, and BMI, birth weight remained positively associated with vertical optic disc diameter and inversely associated with both vertical optic cup diameter and vertical cup/disc ratio (each kilogram increase was associated with a 0.0133-mm larger mean disc diameter; P = 0.04; a 0.0203-mm smaller mean cup diameter; P = 0.02; and a 0.0136 reduction in mean cup/disc ratio; P = 0.002). These associations were not present in children with gestational age less than 33 weeks. Smaller birth length and head circumference were similarly associated with larger cup/disc ratio. Low birth weight

  4. Modeling the Compact Disc Read System in Lab

    ERIC Educational Resources Information Center

    Hinaus, Brad; Veum, Mick

    2009-01-01

    One of the great, engaging aspects of physics is its application to everyday technology. The compact disc player is an example of one such technology that applies fundamental principles from optics in order to efficiently store and quickly retrieve information. We have created a lab in which students use simple optical components to assemble a…

  5. Optic Nerve Head Development in Healthy Infants and Children Using Handheld Spectral-Domain Optical Coherence Tomography.

    PubMed

    Patel, Aarti; Purohit, Ravi; Lee, Helena; Sheth, Viral; Maconachie, Gail; Papageorgiou, Eleni; McLean, Rebecca J; Gottlob, Irene; Proudlock, Frank A

    2016-10-01

    To determine feasibility of optic nerve head (ONH) imaging and to characterize ONH development in full-term infants without sedation using handheld spectral-domain optical coherence tomography (SD OCT). Prospective cross-sectional study. Three hundred fifty-two children aged between 1 day and 13 years. All participants were imaged using handheld SD OCT without sedation during a single scan session. The percentage of successful scans was calculated. Interexaminer reproducibility and differences between right and left eyes were assessed using intraclass correlation coefficients (ICCs). Images were analyzed using ImageJ software. The developmental trajectories over time for ONH parameters were calculated using fractional polynomial modelling. Disc and cup diameter (expressed as distance in micrometers and visual angle in degrees), cup depth, Bruch's membrane opening-minimum rim width (BMO-MRW), retinal thickness, and retinal nerve fiber layer (RNFL; 1700 μm and 6° from the disc center). On average, 70% of participants were imaged successfully. Interexaminer reliability was excellent (ICC, >0.89) for diametric and retinal thickness parameters. Right and left eyes were similar for diametric measurements (ICC, >0.79), but more variable for nasal BMO-MRW, RNFL, and retinal thickness. The mean disc and cup diameter increase by 30% and 40%, respectively, between birth and 13 years of age when expressed as a distance measure, but remained constant (at 5°-5.5° and 2°, respectively) when expressed as a visual angle with reference to the eye nodal point. The peripapillary temporal RNFL demonstrated a marked initial decrease of nearly 35% between birth and approximately 18 months of age. This was followed by a slow increase up to 12 years of age when measured at 1700 μm from the disc center, although there was little change when measured at 6° from the disc center. We demonstrated feasibility of handheld SD OCT imaging of the ONH in full-term infants and children without

  6. Refraction and the axial length of the eyeball in patients with the optic disc drusen.

    PubMed

    Obuchowska, Iwona; Mariak, Zofia

    2009-01-01

    The aim of the study was to demonstrate the relationship between the optic disc drusen (ODD) and the axial length of the eyeball as well as refractive error. We examined prospectively 40 patients with ODD, 18 men and 22 women, age range from 34 to 69 years. All subjects underwent full ophthalmic examination, visual field testing and color-coded duplex sonography of the ocular vessels. Refraction was determined with an autorefractometer (Topcon RM-8000B) and further refined subjectively. Spherical equivalent refraction was calculated as the spherical dioptre plus one half of the cylindrical dioptre. Axial lengths were measured with a Sonomed ultrasound scanner model E-Z Scan AB5500. Clinical signs were observed in 65% of the eyes with drusen, among them, 38% had symptoms of visual acuity loss and all had visual fields defects. There were 21 eyes (18 eyes with and 3 without drusen), with a recorded refractive error. Significant differences in hyperopia were observed between the eyes with and without drusen (p = 0.048). The rate of occurrence of myopia did not differ significantly between affected and unaffected eyes (p = 0.06). The mean spherical equivalent refraction and axial dimensions of the eye differed significantly among the groups of eyes with and without drusen (p < 0.05). Significant differences in mean values of peak-systolic and end-diastolic velocities (p < 0.001) as well as in the resistivity index (p = 0.047) were observed between eyes with and without drusen. The optic disc drusen are often associated with shorter and hyperopic eyes. This anatomical conditions and vascular factors may contribute to pathogenesis of drusen.

  7. The local stability of the magnetized advection-dominated discs with the radial viscous force

    NASA Astrophysics Data System (ADS)

    Ghoreyshi, S. M.; Shadmehri, M.

    2018-06-01

    We study local stability of the advection-dominated optically thick (slim) and optically thin discs with purely toroidal magnetic field and the radial viscous force using a linear perturbation analysis. Our dispersion relation indicates that the presence of magnetic fields and radial viscous force cannot give rise to any new mode of the instability. We find, however, that growth rate of the thermal mode in the slim discs and that of the acoustic modes in the slim and optically thin discs are dramatically affected by the radial viscous force. This force tends to strongly decrease the growth rate of the outward-propagating acoustic mode (O-mode) in the short-wavelength limit, but it causes a slim disc to become thermally more unstable. This means that growth rate of the thermal mode increases in the presence of radial viscous force. This enhancement is more significant when the viscosity parameter is large. The growth rates of the thermal and acoustic modes depend on the magnetic field. Although the instability of O-mode for a stronger magnetic field case has a higher growth rate, the thermal mode of the slim discs can be suppressed when the magnetic field is strong. The inertial-acoustic instability of a magnetized disc may explain the quasi-periodic oscillations (QPOs) from the black holes.

  8. Foxg1 regulates retinal axon pathfinding by repressing an ipsilateral program in nasal retina and by causing optic chiasm cells to exert a net axonal growth-promoting activity.

    PubMed

    Tian, Natasha M; Pratt, Thomas; Price, David J

    2008-12-01

    Mammalian binocular vision relies on the divergence of retinal ganglion cell axons at the optic chiasm, with strictly controlled numbers projecting contralaterally and ipsilaterally. In mouse, contralateral projections arise from the entire retina, whereas ipsilateral projections arise from ventrotemporal retina. We investigate how development of these patterns of projection is regulated by the contralateral determinant Foxg1, a forkhead box transcription factor expressed in nasal retina and at the chiasm. In nasal retina, loss of Foxg1 causes increased numbers of ipsilateral projections and ectopic expression of the ipsilateral determinants Zic2, Ephb1 and Foxd1, indicating that nasal retina is competent to express an ipsilateral program that is normally suppressed by Foxg1. Using co-cultures that combine Foxg1-expressing with Foxg1-null retinal explants and chiasm cells, we provide functional evidence that Foxg1 promotes contralateral projections through actions in nasal retina, and that in chiasm cells, Foxg1 is required for the generation of a hitherto unrecognized activity supporting RGC axon growth.

  9. Nasal Anatomy and Function.

    PubMed

    Patel, Ruchin G

    2017-02-01

    The nose is a complex structure important in facial aesthetics and in respiratory physiology. Nasal defects can pose a challenge to reconstructive surgeons who must re-create nasal symmetry while maintaining nasal function. A basic understanding of the underlying nasal anatomy is thus necessary for successful nasal reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Pattern visual evoked potentials in eyes with disc swelling due to cat scratch disease-associated neuroretinitis.

    PubMed

    Chai, Yuzhu; Yamamoto, Shuichi; Hirayama, Atsuko; Yotsukura, Jiro; Yamazaki, Hiroko

    2005-01-01

    To evaluate optic nerve function by pattern visual evoked potentials (VEPs) in eyes with optic disc swelling due to neuroretinitis associated with cat scratch disease (CSD). Four eyes of four patients with marked optic disc swelling resembling optic neuritis but diagnosed serologically as CSD received systemic steroid treatment. VEPs elicited by black and white checkerboard stimuli created on a TV monitor were recorded before the treatment. The visual acuity (VA) in the affected eyes was decreased to 20/50 in two eyes and finger counting in two eyes at their initial visits. Ophthalmoscopic examination revealed neuroretinitis characterized by severe optic disc swelling, chorioretinal exudates, and macular edema in all eyes. Anti-Bartonella henselae serum antibody was markedly elevated in all patients confirming the diagnosis of CSD. The P100 of the transient VEPs was only mildly reduced without a delay in the implicit times in three eyes and only slightly delayed in the other eye. The steady-state VEPs were mildly reduced in two eyes and phase-reversed in other two eyes. The VA fully recovered after systemic steroid treatment in all patients. Although all examined patients showed marked swelling of the optic disc and visual decrease, the pattern VEPs were not affected as severely as in idiopathic optic neuritis. However, the degree of change of the pattern VEPs varied among patients.

  11. Island composite nasal flap for nasal dorsum skin defects.

    PubMed

    Skitarelić, Neven; Mladina, Ranko; Mraovic, Boris; Simurina, Tatjana; Skitarelić, Nataa; Vuković, Katarina

    2009-08-01

    Skin defects on the nasal dorsum remain a challenge for the plastic surgeon. There are few local nasal flap options for the repair of proximally positioned nasal skin defects. During a 3-year period, 22 patients were treated after excision of skin cancer in the proximal two-thirds of the nose. Nine patients (41%) were female and 13 (59%) were male, with an average age of 69 years. All patients were operated on under local anesthesia. The average follow-up was 25 months. In all patients, after tumor ablation, the skin defect was closed with an island composite nasal skin flap. Pathohistologic analysis confirmed that the margins of the removed tumor were free of malignant cells. Six patients (27.3%) had squamous cell and 16 (72.7%) had basal cell carcinoma. There was no total or partial flap loss. None of the patients has suffered from recurrence of the tumor. The island composite nasal flap is a reliable technique for the closure of proximal nasal skin defects. Complications in the elevation of the island composite flap were rare, and the final result was acceptable.

  12. Planet signatures and Size Segregation in Debris Discs

    NASA Astrophysics Data System (ADS)

    Thébault, Philippe

    2014-01-01

    The response of a debris disc to a planetary perturber is the result of the complex interplay between gravitational effects, grain collisions and stellar radiation pressure (Stark & Kuchner (2009). We investigate to what extent this response can depart from the pure gravitational case when including grain collisional production and radiation pressure. We use the DyCoSS code (Thébault (2012), designed to study the coupled effect of collisions and dynamics for systems at steady state with one perturbing body. We focus on two outcomes: the 2D surface density profile of the disc+planet system, and the way the Particle Size Distribution (PSD) is spatially segregated within the disc. We consider two set-ups: 1) a narrow ring with an exterior ``shepherding'' planet, and 2) an extended disc in which a planet is embedded. For each case, the planet mass and orbit are explored as free parameters, and an unperturbed ``no-planet'' case is also considered. Another parameter is the disc's collisional activity, as parameterized by its optical depth τ.

  13. Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals

    PubMed Central

    Bailey, Ryan S.; Casey, Kevin P.; Pawar, Sachin S.; Garcia, Guilherme J. M.

    2016-01-01

    Importance Historically, otolaryngologists have focused on nasal resistance to airflow and minimum airspace cross-sectional area as objective measures of nasal obstruction using methods such as rhinomanometry and acoustic rhinometry. However, subjective sensation of nasal patency may be more associated with activation of cold receptors by inspired air than with respiratory effort. Objective To investigate whether subjective nasal patency correlates with nasal mucosal temperature in healthy subjects. Design, Setting, and Participants Twenty-two healthy adults were recruited for this study. Subjects first completed the Nasal Obstruction Symptom Evaluation (NOSE) and a unilateral visual analog scale (VAS) to quantify subjective nasal patency. A miniaturized thermocouple sensor was then used to record nasal mucosal temperature bilaterally in two locations along the nasal septum: at the vestibule and across from the inferior turbinate head. Results The range of temperature oscillations during the breathing cycle, defined as the difference between end-expiratory and end-inspiratory temperatures, was greater during deep breaths (ΔTexp-insp = 6.2 ± 2.6°C) than during resting breathing (ΔTexp-insp = 4.2 ± 2.3°C) in both locations (p < 10−13). Mucosal temperature measured at the right vestibule had a statistically significant correlation with both right-side VAS score (Pearson r = −0.55, p=0.0076) and NOSE score (Pearson r = −0.47, p=0.028). No other statistically significant correlations were found between mucosal temperature and subjective nasal patency scores. Nasal mucosal temperature was lower in the first cavity to be measured, which was the right cavity in all subjects. Conclusions and Relevance The greater mucosal temperature oscillations during deep breathing is consistent with the common experience that airflow sensation is enhanced during deep breaths, thus supporting the hypothesis that mucosal cooling plays a central role in nasal airflow sensation

  14. Glaucoma-induced optic disc morphometric changes and glaucoma diagnostic ability of Heidelberg Retina Tomograph II in highly myopic eyes.

    PubMed

    Mayama, Chihiro; Tsutsumi, Tae; Saito, Hitomi; Asaoka, Ryo; Tomidokoro, Atsuo; Iwase, Aiko; Otani, Shinichiro; Miyata, Kazunori; Araie, Makoto

    2014-01-01

    This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glaucoma diagnosis in highly myopic eyes was compared with that in emmetropic eyes. Healthy subjects and age-matched patients with early-stage open-angle glaucoma were divided into two groups: emmetropic eyes (-1.0 to +1.0 diopters) and highly myopic eyes (-12.0 to -5.0 diopters).The participants were comprised of 65 emmetropic normal eyes, 59 emmetropic glaucomatous eyes, 62 highly myopic normal eyes, and 68 highly myopic glaucomatous eyes and eyes with pathologic myopia were carefully excluded. Confocal scanning laser tomographic parameters were compared among all subjects after adjustment for age and disc area. The ROC curves and sensitivity and specificity for glaucoma detection using several clinical methods were then compared between the emmetropic and highly myopic eyes. Rim area, cup/disc area ratio, mean cup depth, and cup shape measure of glaucoma eyes are significantly different from those of normal eyes in both highly myopic eyes and emmetropic eyes. Methodological overestimation of retinal nerve fiber layer cross sectional area due to optic disc tilting was suggested in the highly myopic eyes. The diagnostic performance of glaucoma using several discriminant methods significantly deteriorated in the highly myopic eyes. In the highly myopic glaucomatous eyes, confocal scanning laser tomographic parameters were significantly different from that of non-glaucomatous highly myopic eyes but diagnostic performance of glaucoma was deteriorated than that in emmetropic eyes. These findings demonstrate the utility and limitations of the apparatus in diagnosing glaucoma in highly myopic

  15. Influence of cooling face masks on nasal air conditioning and nasal geometry.

    PubMed

    Lindemann, J; Hoffmann, T; Koehl, A; Walz, E M; Sommer, F

    2017-06-01

    Nasal geometries and temperature of the nasal mucosa are the primary factors affecting nasal air conditioning. Data on intranasal air conditioning after provoking the trigeminal nerve with a cold stimulus simulating the effects of an arctic condition is still missing. The objective was to investigate the influence of skin cooling face masks on nasal air conditioning, mucosal temperature and nasal geometry. Standardized in vivo measurements of intranasal air temperature, humidity and mucosal temperature were performed in 55 healthy subjects at defined detection sites before and after wearing a cooling face mask. Measurements of skin temperature, rhinomanometry and acoustic rhinometry were accomplished. After wearing the face mask the facial skin temperature was significantly reduced. Intranasal air temperature did not change. Absolute humidity and mucosal temperature increased significantly. The acoustic rhinometric results showed a significant increase of the volumes and the cross-sectional areas. There was no change in nasal airflow. Nasal mucosal temperature, humidity of inhaled air, and volume of the anterior nose increased after application of a cold face mask. The response is mediated by the trigeminal nerve. Increased mucosal temperatures as well as changes in nasal geometries seem to guarantee sufficient steady intranasal nasal air conditioning.

  16. Reduced nasal growth after primary nasal repair combined with cleft lip surgery.

    PubMed

    Yoshimura, Y; Okumoto, T; Iijima, Y; Inoue, Y

    2015-11-01

    Nasal growth after cleft lip surgery with or without primary nasal repair was evaluated using lateral cephalograms. In 14 patients who underwent simultaneous nasal repair with primary cleft lip repair and 12 patients without simultaneous nasal repair, lateral cephalograms were obtained at 5 and 10 years of age. Lateral cephalograms of normal Japanese children were used as a control. At 5 years of age, there were significant differences in the nasal height and columellar angle among the three groups. Children without simultaneous nasal repair had shorter noses with more upward tilt of the columella compared with the controls, while children with simultaneous nasal repair had much shorter noses and more upward tilt than those without repair. At 10 years of age, the children without simultaneous nasal repair showed no differences from the control group, while those with simultaneous repair still had shorter noses and more upward tilt of the columella. These findings suggest that performing nasal repair at the same time as primary cleft lip surgery has an adverse influence on the subsequent growth of the nose. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. A tool to separate optical/infrared disc and jet emission in X-ray transient outbursts: the colour-magnitude diagrams of XTE J1550-564

    NASA Astrophysics Data System (ADS)

    Russell, D. M.; Maitra, D.; Dunn, R. J. H.; Fender, R. P.

    2011-09-01

    It is now established that thermal disc emission and non-thermal jet emission can both play a role at optical/infrared (OIR) wavelengths in X-ray transients. The spectra of the jet and disc components differ, as do their dependence on mass accretion properties. Here we demonstrate that the OIR colour-magnitude diagrams (CMDs) of the evolution of the X-ray transient XTE J1550-564 in outburst can be used to separate the disc from the jet. Monitoring in two wavebands is all that is required. This outburst in 2000 was well studied, and both disc and jet were known to contribute. During the outburst the data follow a well-defined path in the CMD, describing what would be expected from a heated single-temperature blackbody of approximately constant area, except when the data appear redder than this track. This is due to the non-thermal jet component which dominates the OIR moreso during hard X-ray states at high luminosities, and which is quenched in the soft state. The CMD therefore shows state-dependent hysteresis, in analogy with (but not identical to) the well-established X-ray hardness-intensity diagram of black hole transients. The blackbody originates in the X-ray illuminated, likely unwarped, outer accretion disc. We show that the CMD can be approximately reproduced by a model that assumes various correlations between X-ray, OIR disc and OIR jet fluxes. We find evidence for the OIR jet emission to be decoupled from the disc near the peak of the hard state.

  18. Multiwavelength studies of the gas and dust disc of IRAS 04158+2805

    NASA Astrophysics Data System (ADS)

    Glauser, A. M.; Ménard, F.; Pinte, C.; Duchêne, G.; Güdel, M.; Monin, J.-L.; Padgett, D. L.

    2008-07-01

    We present a study of the circumstellar environment of IRAS 04158+2805 based on multi-wavelength observations and models. Images in the optical and near-infrared, a polarisation map in the optical, and mid-infrared spectra were obtained with VLT-FORS1, CFHT-IR, and Spitzer-IRS. Additionally we used an X-ray spectrum observed with Chandra. We interpret the observations in terms of a central star surrounded by an axisymmetric circumstellar disc, but without an envelope, to test the validity of this simple geometry. We estimate the structural properties of the disc and its gas and dust content. We modelled the dust disc with a 3D continuum radiative transfer code, MCFOST, based on a Monte-Carlo method that provides synthetic scattered light images and polarisation maps, as well as spectral energy distributions. We find that the disc images and spectral energy distribution narrowly constrain many of the disc model parameters, such as a total dust mass of 1.0-1.75×10-4 M_⊙ and an inclination of 62°-63°. The maximum grain size required to fit all available data is of the order of 1.6-2.8 μm although the upper end of this range is loosely constrained. The observed optical polarisation map is reproduced well by the same disc model, suggesting that the geometry we find is adequate and the optical properties are representative of the visible dust content. We compare the inferred dust column density to the gas column density derived from the X-ray spectrum and find a gas-to-dust ratio along the line of sight that is consistent with the ISM value. To our knowledge, this measurement is the first to directly compare dust and gas column densities in a protoplanetary disc. Based on observations obtained at the Canada-France-Hawaii Telescope (CFHT) which is operated by the National Research Council of Canada, the Institut National des Sciences de l'Univers of the Centre National de la Recherche Scientifique of France, and the University of Hawaii. Based also on data collected

  19. Reproducibility of peripapillary retinal nerve fiber layer thickness with spectral domain cirrus high-definition optical coherence tomography in normal eyes.

    PubMed

    Hong, Samin; Kim, Chan Yun; Lee, Won Seok; Seong, Gong Je

    2010-01-01

    To assess the reproducibility of the new spectral domain Cirrus high-definition optical coherence tomography (HD-OCT; Carl Zeiss Meditec, Dublin, CA, USA) for analysis of peripapillary retinal nerve fiber layer (RNFL) thickness in healthy eyes. Thirty healthy Korean volunteers were enrolled. Three optic disc cube 200 x 200 Cirrus HD-OCT scans were taken on the same day in discontinuous sessions by the same operator without using the repeat scan function. The reproducibility of the calculated RNFL thickness and probability code were determined by the intraclass correlation coefficient (ICC), coefficient of variation (CV), test-retest variability, and Fleiss' generalized kappa (kappa). Thirty-six eyes were analyzed. For average RNFL thickness, the ICC was 0.970, CV was 2.38%, and test-retest variability was 4.5 microm. For all quadrants except the nasal, ICCs were 0.972 or higher and CVs were 4.26% or less. Overall test-retest variability ranged from 5.8 to 8.1 microm. The kappa value of probability codes for average RNFL thickness was 0.690. The kappa values of quadrants and clock-hour sectors were lower in the nasal areas than in other areas. The reproducibility of Cirrus HD-OCT to analyze peripapillary RNFL thickness in healthy eyes was excellent compared with the previous reports for time domain Stratus OCT. For the calculated RNFL thickness and probability code, variability was relatively higher in the nasal area, and more careful analyses are needed.

  20. Pars plana vitrectomy with juxtapapillary laser photocoagulation versus vitrectomy without juxtapapillary laser photocoagulation for the treatment of optic disc pit maculopathy: the results of the KKESH International Collaborative Retina Study Group.

    PubMed

    Abouammoh, Marwan A; Alsulaiman, Sulaiman M; Gupta, Vishali S; Mousa, Ahmed; Hirakata, Akito; Berrocal, Maria H; Chenworth, Megan; Chhablani, Jay; Oshima, Yusuke; AlZamil, Waseem M; Casella, Antonio Marcelo; Papa-Oliva, Gabriela; Banker, Alay S; Arevalo, J Fernando

    2016-04-01

    To compare the functional and anatomic outcomes of pars plana vitrectomy (PPV) with juxtapapillary laser photocoagulation (JLP) versus vitrectomy without JLP in optic disc pit maculopathy. This was a multicentre, retrospective study of 46 consecutive patients with optic disc pit maculopathy presenting at tertiary eye centres between 1992 and 2012. Indications for surgery included distorted or decreased vision. Surgical intervention included PPV, posterior vitreous detachment, with or without gas tamponade. Twenty-four patients received laser photocoagulation at the temporal edge of the optic disc pit (group A) and 22 patients had no laser (group B). Postoperative best-corrected visual acuity (BCVA) and optical coherence tomography findings were the main outcome measures. Mean follow-up was 44 months (range 12-98 months). BCVA in group A improved significantly from 0.7 logMAR (20/100) preoperatively to 0.5 logMAR (20/60) postoperatively (p=0.017). In group B, BCVA improved from 0.7 logMAR (20/100) preoperatively to 0.4 logMAR (20/40) postoperatively (p=0.014). The difference in final BCVA between groups was not statistically significant (p=0.693). The mean central macular thickness (CMT) in group A improved significantly from 750 μm preoperatively to 309 μm at last follow-up (p<0.0001). The mean CMT in group B improved from 616 μm preoperatively to 291 μm at last follow-up (p=0.028). The difference in final CMT between groups was not statistically significant (p=0.747). PPV with JLP for optic disc pit maculopathy had similar functional and anatomic outcomes compared with vitrectomy without JLP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. [Endoscopic treatment of small osteoma of nasal sinuses manifested as nasal and facial pain].

    PubMed

    Li, Yu; Zheng, Tianqi; Li, Zhong; Deng, Hongyuan; Guo, Chaoxian

    2015-12-01

    To discuss the clinical features, diagnosis and endoscopic surgical intervention for small steoma of nasal sinuses causing nasal and facial pain. A retrospective review was performed on 21 patients with nasal and facial pain caused by small osteoma of nasal sinuses, and nasal endoscopic surgery was included in the treatment of all cases. The nasal and facial pain of all the patients was relieved. Except for one ase exhibiting periorbital bruise after operation, the other patients showed no postoperative complications. Nasal and facial pain caused by small osteoma of nasal sinuses was clinically rare, mostly due to the neuropathic pain of nose and face caused by local compression resulting from the expansion of osteoma. Early diagnosis and operative treatment can significantly relieve nasal and facial pain.

  2. Planet-disc interaction in laminar and turbulent discs

    NASA Astrophysics Data System (ADS)

    Stoll, Moritz H. R.; Picogna, Giovanni; Kley, Wilhelm

    2017-07-01

    In weakly ionised discs turbulence can be generated through the vertical shear instability (VSI). Embedded planets are affected by a stochastic component in the torques acting on them, which can impact their migration. In this work we study the interplay between a growing planet embedded in a protoplanetary disc and the VSI turbulence. We performed a series of 3D hydrodynamical simulations for locally isothermal discs with embedded planets in the mass range from 5 to 100 Earth masses. We study planets embedded in an inviscid disc that is VSI unstable, becomes turbulent, and generates angular momentum transport with an effective α = 5 × 10-4. This is compared to the corresponding viscous disc using exactly this α-value. In general we find that the planets have only a weak impact on the disc turbulence. Only for the largest planet (100 M⊕) does the turbulent activity become enhanced inside of the planet. The depth and width of a gap created by the more massive planets (30,100 M⊕) in the turbulent disc equal exactly that of the corresponding viscous case, leading to very similar torque strengths acting on the planet, with small stochastic fluctuations for the VSI disc. At the gap edges vortices are generated that are stronger and longer-lived in the VSI disc. Low mass planets (with Mp ≤ 10 M⊕) do not open gaps in the disc in either case, but generate for the turbulent disc an overdensity behind the planet that exerts a significant negative torque. This can boost the inward migration in VSI turbulent discs well above the Type I rate. Owing to the finite turbulence level in realistic 3D discs the gap depth will always be limited and migration will not stall in inviscid discs.

  3. Comparison of animal discs used in disc research to human lumbar disc: torsion mechanics and collagen content.

    PubMed

    Showalter, Brent L; Beckstein, Jesse C; Martin, John T; Beattie, Elizabeth E; Espinoza Orías, Alejandro A; Schaer, Thomas P; Vresilovic, Edward J; Elliott, Dawn M

    2012-07-01

    Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these with the human disc. To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar discs, and cow, rat, and mouse caudal discs. Collagen content was measured and normalized by dry weight for the same discs except the rat and the mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human discs. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Disc torsion mechanics are comparable with human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented are useful for selecting and interpreting results for animal disc models. Structural organization of the fiber angle may explain the differences that were noted between species after geometric normalization.

  4. Oxymetazoline Nasal Spray

    MedlinePlus

    ... is recommended by a doctor. Children 6 to 12 years of age should use oxymetazoline nasal spray carefully and under adult supervision. Oxymetazoline is in a class of medications called nasal decongestants. It works by narrowing the blood vessels in the nasal passages.

  5. Validation of polyvinylidene fluoride nasal sensor to assess nasal obstruction in comparison with subjective technique.

    PubMed

    Roopa Manjunatha, G; Mahapatra, D Roy; Prakash, Surya; Rajanna, K

    2015-01-01

    The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14±5.87% and 48.85±5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33±10.54% and LN: 32.24±11.54%). Moderate correlation was observed in healthy group (r=-0.710, p<0.001 for RN and r=-0.651, p<0.001 for LN), and moderate to strong correlation in patient group (r=-0.751, p<0.01 for RN and r=-0.885, p<0.0001 for LN). PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. The clinical study of percutaneous disc decompression of treating herniation of cervical disc with Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Zhang, Dianxue; Cheng, Hefu; Wang, Jindong

    2005-07-01

    Objective: The possibility of PLDD (percutaneous laser disc decompression) and an ideal non-operative method which is long everlasting effect for PLDD was investigated. Methods: 159 patients of Cervical Disc Herniation with PLDD were studied. All the herniated discs were irradiated with 10­15J/S Nd:YAG laser quantum through optical-fiber under the supervision of C-arm X-ray. Results: All the patients were followed and reexamined CT or MRI after one to six months of PLDD. The result of cured (67.92%), excellent (24.53%), moderation (5.66%), non-effect (1.88%) was got. The excellent rate was 88.24%. The effective rate was 97.65%. Non-effective rate was 2.35%. Conclusion: When irradiated with Nd:YAG laser, the nucleus pulposus was vapouring, charring and coagulating. The volume and inner-pressure of the disc decreased. So the symptoms and signs improved. The main value of this methods were micro-damage, non-operation, no bleeding, no bone injury, good therapy effect, quick recovery, lesser pain, safety and excellent long everlasting effect. It is an ideal non-operative method of treating PLDD.

  7. The extremely truncated circumstellar disc of V410 X-ray 1: a precursor to TRAPPIST-1?

    NASA Astrophysics Data System (ADS)

    Boneberg, D. M.; Facchini, S.; Clarke, C. J.; Ilee, J. D.; Booth, R. A.; Bruderer, S.

    2018-06-01

    Protoplanetary discs around brown dwarfs and very low mass (VLM) stars offer some of the best prospects for forming Earth-sized planets in their habitable zones. To this end, we study the nature of the disc around the VLM star V410 X-ray 1, whose spectral energy distribution (SED) is indicative of an optically thick and very truncated dust disc, with our modelling suggesting an outer radius of only 0.6 au. We investigate two scenarios that could lead to such a truncation, and find that the observed SED is compatible with both. The first scenario involves the truncation of both the dust and gas in the disc, perhaps due to a previous dynamical interaction or the presence of an undetected companion. The second scenario involves the fact that a radial location of 0.6 au is close to the expected location of the H2O snowline in the disc. As such, a combination of efficient dust growth, radial migration, and subsequent fragmentation within the snowline leads to an optically thick inner dust disc and larger, optically thin outer dust disc. We find that a firm measurement of the CO J = 2-1 line flux would enable us to distinguish between these two scenarios, by enabling a measurement of the radial extent of gas in the disc. Many models we consider contain at least several Earth-masses of dust interior to 0.6 au, suggesting that V410 X-ray 1 could be a precursor to a system with tightly packed inner planets, such as TRAPPIST-1.

  8. Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals.

    PubMed

    Bailey, Ryan S; Casey, Kevin P; Pawar, Sachin S; Garcia, Guilherme J M

    2017-01-01

    Historically, otolaryngologists have focused on nasal resistance to airflow and minimum airspace cross-sectional area as objective measures of nasal obstruction using methods such as rhinomanometry and acoustic rhinometry. However, subjective sensation of nasal patency may be more associated with activation of cold receptors by inspired air than with respiratory effort. To investigate whether subjective nasal patency correlates with nasal mucosal temperature in healthy individuals. Healthy adult volunteers first completed the Nasal Obstruction Symptom Evaluation (NOSE) and a unilateral visual analog scale to quantify subjective nasal patency. A miniaturized thermocouple sensor was then used to record nasal mucosal temperature bilaterally in 2 locations along the nasal septum: at the vestibule and across from the inferior turbinate head. Nasal mucosal temperature and subjective patency scores in healthy individuals. The 22 healthy adult volunteers (12 [55%] male; mean [SD] age, 28.3 [7.0] years) had a mean (SD) NOSE score of 5.9 (8.4) (range, 0-30) and unilateral VAS score of 1.2 (1.4) (range, 0-5). The range of temperature oscillations during the breathing cycle, defined as the difference between end-expiratory and end-inspiratory temperatures, was greater during deep breaths (mean [SD] change in temperature, 6.2°C [2.6°C]) than during resting breathing (mean [SD] change in temperature, 4.2°C [2.3°C]) in both locations (P < .001). Mucosal temperature measured at the right vestibule had a statistically significant correlation with both right-side visual analog scale score (Pearson r = -0.55; 95% CI, -0.79 to -0.17; P = .008) and NOSE score (Pearson r = -0.47; 95% CI, -0.74 to -0.06; P = .03). No other statistically significant correlations were found between mucosal temperature and subjective nasal patency scores. Nasal mucosal temperature was lower (mean of 1.5°C lower) in the first cavity to be measured, which was the right cavity in all

  9. Comparison of Animal Discs Used in Disc Research to Human Lumbar Disc: Torsion Mechanics and Collagen Content

    PubMed Central

    Showalter, Brent L.; Beckstein, Jesse C.; Martin, John T.; Beattie, Elizabeth E.; Orías, Alejandro A. Espinoza; Schaer, Thomas P.; Vresilovic, Edward J.; Elliott, Dawn M.

    2012-01-01

    Study Design Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these to the human disc. Objective To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. Summary of Background Data There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Methods Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar, and cow, rat, and mouse caudal. Collagen content was measured and normalized by dry weight for the same discs except the rat and mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Results Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Conclusion Disc torsion mechanics are comparable to human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented is useful for selecting and interpreting results for animal models of the disc. Structural composition of the disc, such as initial fiber angle, may explain the differences that were noted between species after geometric normalization. PMID:22333953

  10. Internal retinal layer thickness and macular migration after internal limiting membrane peeling in macular hole surgery.

    PubMed

    Faria, Mun Y; Ferreira, Nuno P; Mano, Sofia; Cristóvao, Diana M; Sousa, David C; Monteiro-Grillo, Manuel E

    2018-05-01

    To provide a spectral-domain optical coherence tomography (SD-OCT)-based analysis of retinal layers thickness and nasal displacement of closed macular hole after internal limiting membrane peeling in macular hole surgery. In this nonrandomized prospective interventional study, 36 eyes of 32 patients were subjected to pars plana vitrectomy and 3.5 mm diameter internal limiting membrane (ILM) peeling for idiopathic macular hole (IMH). Nasal and temporal internal retinal layer thickness were assessed with SD-OCT. Each scan included optic disc border so that distance between optic disc border and fovea were measured. Thirty-six eyes had a successful surgery with macular hole closure. Total nasal retinal thickening (p<0.001) and total temporal retinal thinning (p<0.0001) were observed. Outer retinal layers increased thickness after surgery (nasal p<0.05 and temporal p<0.01). Middle part of inner retinal layers (mIRL) had nasal thickening (p<0.001) and temporal thinning (p<0.05). The mIRL was obtained by deducting ganglion cell layer (GCL) and retinal nerve fiber layer (RNFL) thickness from overall thickness of the inner retinal layer. Papillofoveal distance was shorter after ILM peeling in macular hole surgery (3,651 ± 323 μm preoperatively and 3,361 ± 279 μm at 6 months; p<0.0001). Internal limiting membrane peel is associated with important alteration in inner retinal layer architecture, with thickening of mIRL and shortening of papillofoveal distance. These factors may contribute to recovery of disrupted foveal photoreceptor and vision improvement after IMH closure.

  11. Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes.

    PubMed

    El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N

    2003-11-01

    To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to

  12. [Dexpanthenol nasal spray in comparison to dexpanthenol nasal ointment. A prospective, randomised, open, cross-over study to compare nasal mucociliary clearance].

    PubMed

    Verse, T; Klöcker, N; Riedel, F; Pirsig, W; Scheithauer, M O

    2004-07-01

    Recent technical developments in metered pump systems allow the production and use of preservative-free nasal products. The aim of the current study is to compare the tolerability of a preservative-free dexpanthenol (5%) nasal spray with that of the established dexpanthenol (5%) nasal ointment, also without preservatives. The main outcome measure was in vivo mucociliary clearance. Mucociliary clearance was assessed by saccharin migration time in 20 volunteers. Wash-out phases were 7 days and the spray or ointment was always applied 20 min before the saccharin test. The study was designed to test for non-inferiority. Saccharin migration time was slightly longer after ointment administration, however, these were not significantly different to nasal spray. The saccharin migration time showed a significant correlation with the age of the volunteers. The upper confidence limit of dexpanthenol nasal spray was markedly less than that of the ointment. Therefore, dexpanthenol nasal spray is at least equal to if not better than dexpanthenol nasal ointment. Due to its ease of administration, preservative-free dexpanthenol nasal spray offers a valuable therapeutic alternative.

  13. Nasal Cancer

    MedlinePlus

    ... the way to your throat as you breathe. Cancer of the nasal cavity and paranasal sinuses is ... be like those of infections. Doctors diagnose nasal cancer with imaging tests, lighted tube-like instruments that ...

  14. Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma.

    PubMed

    Murphy, Melissa L; Pokrovskaya, Olya; Galligan, Marie; O'Brien, Colm

    2017-01-10

    To compare corneal hysteresis (CH) measurements between patients with glaucoma, ocular hypertension (OHT) and glaucoma-like optic discs (GLD)- defined as a cup to disc ratio greater than or equal to 0.6 with normal intraocular pressure (IOP) and visual fields. The secondary aim was to investigate whether corneal resistance factor (CRF) and central corneal thickness (CCT) differ between patient groups. In this cross sectional study a total of 123 patients (one eye each) were recruited from a glaucoma outpatient department to undergo ocular response analyser (ORA) testing and ultrasound pachymetry as well as clinical examination. A One-way Analysis of Covariance (ANCOVA) was conducted to evaluate the mean difference in CH between the three diagnostic groups (glaucoma, OHT and GLD) correcting for potential confounding factors, IOP and age. Analysis was repeated for CRF and CCT. There was a significant difference in mean CH across the three diagnosis groups; F(2, 115) = 96.95; p < 0.001. Mean CH significantly higher for GLD compared to glaucoma (mean difference 1.83, p < 0.001), and significantly higher for OHT compared to glaucoma (mean difference 2.35, p < 0.001). Mean CH was slightly lower in patients with GLD than those with OHT but this difference was not statistically significant. A similar pattern was seen when the analysis was repeated for CRF and CCT. Higher CH in GLD and OHT compared to glaucoma suggests increased viscoelasticity of ocular tissues may have a protective role against glaucoma.

  15. Nasal Physiology

    MedlinePlus

    ... Anatomy Virtual Anatomy Disclosure Statement Printer Friendly Nasal Physiology Jeremiah A. Alt, MD, PhD Noam Cohen, MD, ... control the inflammation. CONCLUSION An understanding of the physiology of the nose is critical to understand nasal ...

  16. [Effect of absorption enhancers on nasal ginsenoside Rg1 delivery and its nasal ciliotoxicity].

    PubMed

    Chen, Xin-mei; Zhu, Jia-bi; Sun, Wei-dong; Zhang, Li-jian

    2006-02-01

    The enhancing activity and safety of several absorption enhancers were evaluated as potential nasal absorption enhancers to increase intranasal absorption of ginsenoside Rg1. Nasal circulatory perfusion test in vivo had been employed to investigate the effect of absorption enhancers for nasal mucosa absorption of ginsenoside Rgl in rats. The safety of the absorption enhancers were evaluated by testing cilia movement of the in situ toad palate model, the hemolysis of erythrocyte membrane of the rabbit, leaching of protein and LDH from the mice nasal mucosa and the effect on cilia structural and specific cellular changes of nasal mucosa. Absorption enhancers were necessary to facilitate ginsenoside Rg1 absorption by nasal mucosa. Among the absorption enhancers 1% sodium deoxycholate had great effect to facilite ginsenoside Rgl absorption by nasal mucosa; 1% dipotassium glycyrrhizinate and 1% azone had moderate effect to facilitate ginsenoside Rg1 absorption by nasal mucosa; 1% Tween-80, 2% beta-cyclodextrin, 0.5% borneol (dissolved in paraffin liquid), 0.5% chitosan, 5% hydroxypropyl-beta-cyclodextrin and 0.1% EDTA had low effect to facilitate ginsenoside Rgl absorption by nasal mucosa. 1% sodium deoxycholate, 1% azone and 1% dipotassium glycyrrhizinate had serious nasal toxicity; 1% Tween-80, 2% beta-cyclodextrin, 5% hydroxypropyl-beta-cyclodextrin had moderate nasal toxicity; 0.5% borneol (dissolved in paraffin liquid), 0.5% chitosan and 0.1% EDTA have little nasal toxicity. 0.5% borneol and 0.5% chitosan were the promising candidates having a good balance between enhancing activity and safety for nasal ginsenoside Rg1 delivery.

  17. Differences in Optic Nerve Head, Retinal Nerve Fiber Layer, and Ganglion Cell Complex Parameters Between Caucasian and Chinese Subjects.

    PubMed

    Chansangpetch, Sunee; Huang, Guofu; Coh, Paul; Oldenburg, Catherine; Amoozgar, Behzad; He, Mingguang; Lin, Shan C

    2018-04-01

    To compare optic nerve head, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell complex (GCC) parameters between Caucasian and ethnic Chinese. Normal subjects above 40 years old and self-identified as being Caucasian and Chinese were recruited. They were evaluated with spectral-domain optical coherence tomography (RTVue-100). Parameters related to the optic nerve head, pRNFL, and GCC analysis protocols were acquired. Multivariable linear regression was performed adjusting for potential confounders. Data from 116 Caucasian and 130 Chinese subjects were available for analysis. Mean age of all participants was 66.72 (SD 10.82) years. There were statistically significant differences for disc area (DA), area cup-to-disc, vertical cup-to-disc, and cup volume (P=0.02, 0.004, 0.02, and 0.03, respectively), greater in Chinese. After adjusting for age, sex, axial length (AL), intraocular pressure (IOP), DA, and GCC thickness, Chinese subjects had significantly greater thickness in all pRNFL parameters (mean differences ranged between 4.29 and 9.93 μm; all P<0.001) except the nasal quadrant. GCC outcomes were also adjusted for DA and pRNFL; Caucasians had significantly higher average GCC and inferior GCC (mean difference 2.97 and 3.45 μm, respectively; P<0.01), whereas the Chinese group had significantly higher ganglion cell global loss volume (mean difference 2.47 %, P<0.001). This study suggests there is significantly greater pRNFL thickness in Chinese, which were independent of age, AL, IOP, and DA, and possibly greater GCC in Caucasians after adjustment for age, AL, IOP, DA, and pRNFL thickness.

  18. A Herschel resolved debris disc around HD 105211

    NASA Astrophysics Data System (ADS)

    Hengst, S.; Marshall, J. P.; Horner, J.; Marsden, S. C.

    2017-07-01

    Debris discs are the dusty aftermath of planet formation processes around main-sequence stars. Analysis of these discs is often hampered by the absence of any meaningful constraint on the location and spatial extent of the disc around its host star. Multi-wavelength, resolved imaging ameliorates the degeneracies inherent in the modelling process, making such data indispensable in the interpretation of these systems. The Herschel Space Observatory observed HD 105211 (η Cru, HIP 59072) with its Photodetector Array Camera and Spectrometer (PACS) instrument in three far-infrared wavebands (70, 100 and 160 μm). Here we combine these data with ancillary photometry spanning optical to far-infrared wavelengths in order to determine the extent of the circumstellar disc. The spectral energy distribution and multi-wavelength resolved emission of the disc are simultaneously modelled using a radiative transfer and imaging codes. Analysis of the Herschel/PACS images reveals the presence of extended structure in all three PACS images. From a radiative transfer model we derive a disc extent of 87.0 ± 2.5 au, with an inclination of 70.7 ± 2.2° to the line of sight and a position angle of 30.1 ± 0.5°. Deconvolution of the Herschel images reveals a potential asymmetry but this remains uncertain as a combined radiative transfer and image analysis replicates both the structure and the emission of the disc using a single axisymmetric annulus.

  19. Peripapillary nerve fiber layer thickness measurement reproducibility using optical coherence tomography.

    PubMed

    Villain, Max A; Greenfield, David S

    2003-01-01

    To assess reproducibility of quadrantic and clock hour sectors of retinal nerve fiber layer thickness in normal eyes using optical coherence tomography. Normal eyes of healthy volunteers meeting eligibility criteria were imaged by two inexperienced operators. Six 360 degrees circular scans with a diameter of 3.4 mm centered on the optic disc were obtained during each scanning session, and a baseline image was formed using 3 high-quality images defined by the software. Images were obtained on three different days within a 4-week period. Variance and coefficient of variation (CV) were calculated for quadrantic and retinal nerve fiber layer clock hour sectors obtained from the baseline image. Five normal eyes were scanned. Intraoperator reproducibility was high. The mean (+/- SD) CV for total retinal nerve fiber layer thickness was 5.3 +/- 3.82% and 4.33 +/- 3.7% for operators 1 and 2, respectively. Interoperator reproducibility was good with statistically similar variance for all quadrantic and clock hour retinal nerve fiber layer parameters (P = .42 to .99). The nasal retinal nerve fiber layer was the most variable sector for both operators (mean CV: 10.42% and 7.83% for operators 1 and 2, respectively). Differences in mean total, nasal, temporal, and superior retinal nerve fiber layer thickness were not statistically significant between operators for all eyes; however, for inferior retinal nerve fiber layer thickness, there was a significant (P = .0007) difference between operators in one eye. Peripapillary retinal nerve fiber layer thickness assessments using optical coherence tomography have good intraoperator and interoperator reproducibility. Inexperienced operators can generate useful measurement data with acceptable levels of variance.

  20. Nasal computed tomography.

    PubMed

    Kuehn, Ned F

    2006-05-01

    Chronic nasal disease is often a challenge to diagnose. Computed tomography greatly enhances the ability to diagnose chronic nasal disease in dogs and cats. Nasal computed tomography provides detailed information regarding the extent of disease, accurate discrimination of neoplastic versus nonneoplastic diseases, and identification of areas of the nose to examine rhinoscopically and suspicious regions to target for biopsy.

  1. Radial optic neurotomy for ischaemic central vein occlusion

    PubMed Central

    Martínez-Jardón, C S; Meza-de Regil, A; Dalma-Weiszhausz, J; Leizaola-Fernández, C; Morales-Cantón, V; Guerrero-Naranjo, J L; Quiroz-Mercado, H

    2005-01-01

    Background/aims: Ischaemic central retinal vein occlusion (CRVO) accounts for 20–50% of all CRVO. No treatment has been proved to be effective. The efficacy of radial optic neurotomy (RON) was evaluated in eyes with ischaemic CRVO. Methods: 10 patients with ischaemic CRVO underwent RON. After pars plana vitrectomy, a microvitreoretinal blade was used to incise the scleral ring, cribriform plate, and adjacent sclera at the nasal edge of the optic disc. Best corrected visual acuity (BCVA), intraocular pressure (IOP), fluorescein angiography (FA), multifocal electroretinography (mfERG), and optical coherence tomography (OCT) were measured preoperatively and at 1, 3, and 6 months postoperatively. Results: No visual improvement was noted in the eyes that underwent RON. FA and mfERG showed no increase in retinal perfusion or retinal function postoperatively. Mean macular central thickness changed from 841 (SD 170) μm preoperatively to 162 (SD 34) μm at the sixth postoperative month. One patient had retinal central artery perforation intraoperatively. One patient developed neovascular glaucoma. Conclusion: RON in ischaemic CRVO did not improve visual function (by mfERG) or visual acuity although macular thickness did improve. This technique may be associated with potential risks. Randomised studies are needed to corroborate these results. PMID:15834084

  2. Nasal carriage and antimicrobial susceptibility of Staphylococcus aureus in healthy preschool children in Ujjain, India.

    PubMed

    Pathak, Ashish; Marothi, Yogyata; Iyer, Rama V; Singh, Binita; Sharma, Megha; Eriksson, Bo; Macaden, Ragini; Lundborg, Cecilia Stålsby

    2010-12-29

    There is increasing evidence that community acquired S. aureus infections are spreading among healthy children. Nasal colonization with S. aureus plays pivotal role in the increasing prevalence of resistant community acquired S. aureus infections worldwide. A regular surveillance system is important in ensuring quality of patient care. The aim of the study was to assess the prevalence of and the factors associated with nasal carriage of S. aureus and its antibiotic sensitivity pattern among healthy children in Ujjain, India. A prospective study was done in paediatric outpatient clinics of R.D. Gardi medical college Ujjain, India. Healthy children from 1 month to 59 months of age were included. Information on previously known risk factors for nasal colonization was collected using a pre-tested questionnaire. Swabs from anterior nares were collected and transported in Amies transport media with charcoal and cultured on 5% sheep blood agar. Antibiotic sensitivity tests were performed using Kirby Bauer's disc diffusion method according to performance standards of Clinical and Laboratory Standard Institute guidelines. Of the 1,562 children from 1-month up-to five years of age included in the study 98 children tested positive for nasal carriage of S. aureus. The prevalence of nasal carriage of S. aureus was 6.3% (95% CI 5.1-7.5) out of which 16.3% (95% CI 8.9-23.8) were methicillin-resistant S. aureus (MRSA). The factors associated with nasal carriage were "child attending preschool" (OR 4.26, 95% CI 2.25-8.03; P = 0.007) or "school" (OR 3.02, 95% CI 1.27-7.18; P < 0.001) and "family size more than 10 members" (OR 2.76 95% CI 1.06-7.15; P = 0.03). The sensitivity pattern of isolated S. aureus showed resistance to commonly used oral antibiotics while resistance to glycopeptides was not noted. We found a relatively low rate of nasal carriage of S. aureus in children below five years when compared to children of older age groups in India. Yet, prevalence of MRSA was

  3. Study of Interpolated Timing Recovery Phase-Locked Loop with Linearly Constrained Adaptive Prefilter for Higher-Density Optical Disc

    NASA Astrophysics Data System (ADS)

    Kajiwara, Yoshiyuki; Shiraishi, Junya; Kobayashi, Shoei; Yamagami, Tamotsu

    2009-03-01

    A digital phase-locked loop (PLL) with a linearly constrained adaptive filter (LCAF) has been studied for higher-linear-density optical discs. LCAF has been implemented before an interpolated timing recovery (ITR) PLL unit in order to improve the quality of phase error calculation by using an adaptively equalized partial response (PR) signal. Coefficient update of an asynchronous sampled adaptive FIR filter with a least-mean-square (LMS) algorithm has been constrained by a projection matrix in order to suppress the phase shift of the tap coefficients of the adaptive filter. We have developed projection matrices that are suitable for Blu-ray disc (BD) drive systems by numerical simulation. Results have shown the properties of the projection matrices. Then, we have designed the read channel system of the ITR PLL with an LCAF model on the FPGA board for experiments. Results have shown that the LCAF improves the tilt margins of 30 gigabytes (GB) recordable BD (BD-R) and 33 GB BD read-only memory (BD-ROM) with a sufficient LMS adaptation stability.

  4. Does the Supine Position Affect the Nasal Profile in Rhinoplasty Patients? A Comparison of Nasal Anthropometric Measurements in Different Body Positions.

    PubMed

    Kim, Su Jin; Ryu, In Yong; Kim, Sung Wan; Lee, Kun Hee

    2017-10-16

    Rhinoplasty surgeons are aware that the nasal profile differs according to body position, namely, the erect position in the consultation room vs the supine position on the operating table. It is not clear whether this difference is caused by an optical illusion or skin laxity due to positional change. To evaluate anthropometric measurements of the nose with different body positions and determine whether the supine position affects the nasal profile. In this retrospective study, 103 patients who underwent primary rhinoplasty were enrolled. Preoperatively, all patients underwent lateral cephalography in the erect position, and facial computed tomography (CT), in the supine position. We measured four nasal anthropometric parameters (the nasofrontal, nasolabial, and nasomental angles, and Simon's ratio) on lateral cephalograms and facial CT images, and compared these parameters between the two body positions. The nasofrontal angle was greater on facial CT than on cephalograms (P < 0.01). This difference was not related to age, sex, or body mass index (P > 0.05 each). We found no significant difference (P > 0.05) between the two positions in the nasolabial angle, nasomental angle, or Simon's ratio. The supine position does affect the nasal profile, especially in the radix area. Surgeons need to consider this difference in patients undergoing rhinoplasty. 2. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  5. Perception of Better Nasal Patency Correlates with Increased Mucosal Cooling after Surgery for Nasal Obstruction

    NASA Astrophysics Data System (ADS)

    Garcia, Guilherme; Sullivan, Corbin; Frank-Ito, Dennis; Kimbell, Julia; Rhee, John

    2014-11-01

    Nasal airway obstruction (NAO) is a common health problem with 340,000 patients undergoing surgery annually in the United States. Traditionally, otolaryngologists have focused on airspace cross-sectional areas and nasal resistance to airflow as objective measures of nasal patency, but neither of these variables correlated consistently with patients' symptoms. Given that the sensation of nasal airflow is also associated with mucosal cooling (i.e., heat loss) during inspiration, we investigated the correlation between the sensation of nasal obstruction and mucosal cooling in 10 patients before and after NAO surgery. Three-dimensional models of the nasal anatomy were created based on pre- and post-surgery computed tomography scans. Computational fluid dynamics (CFD) simulations were conducted to quantify nasal resistance and mucosal cooling. Patient-reported symptoms were measured by a visual analog scale and the Nasal Obstruction Symptom Evaluation (NOSE), a disease-specific quality of life questionnaire. Our results revealed that the subjective sensation of nasal obstruction correlated with both nasal resistance and heat loss, but the strongest correlation was between the NOSE score and the nasal surface area where heat flux exceeds 50 W /m2 . In conclusion, a significant post-operative increase in mucosal cooling correlates well with patients' perception of better nasal patency after NAO surgery.

  6. [Clinical effects of nasal glucocorticoid on amelioration of nasal obstruction in patients with persistent non-allergic rhinitis].

    PubMed

    Sail, Giyab A; Zuo, Ke-jun; Xu, Geng

    2009-09-01

    To observe the efficacy of nasal glucocorticoid continuously used for 12 weeks on nasal obstruction in patients with persistent non-allergic rhinitis (PNAR). The changes of nasal obstruction, nasal resistance, nasal mucous membrane and quality of life in 47 patients with PNAR were observed. The efficacy of nasal glucocorticoid (Mometasone Furoate Nasal Spray, MFNS 200 microg/day) on patients with PNAR was evaluated. The results of nasal glucocorticoid (MFNS) continuously used for 12 weeks demonstrated: (1) After treatment, the nasal obstruction, nasal discharge, nasal obstruction related dizziness, headache, hyposmia, daily life activity, whole body fatigue, mental status were significantly improved (P < 0.05). (2) Nasal resistance showed significant amelioration (pre-treatment = 0.28 +/- 0.10, post- treatment = 0.16 +/- 0.05; F = 91.471, P < 0.05). (3) SF-36 questionnaire revealed that role physical, bodily pain, general health, role emotional had significant amelioration (P < 0.01). (4) SNOT-20 questionnaire revealed that the defatigation, impaired concentration, pinch the nose, nasal discharging into the throat, sleep quality had significant amelioration (P < 0.01). (5) Continued treatment for 12 weeks was better than 4 weeks, continued treatment had good effect. The study shows that nasal glucocorticoid improved the nasal obstruction, nasal resistance, nasal mucous membrane and quality of life in patients with PNAR.

  7. Automatic classification of pathological myopia in retinal fundus images using PAMELA

    NASA Astrophysics Data System (ADS)

    Liu, Jiang; Wong, Damon W. K.; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Saw, Seang Mei; Tong, Louis; Wong, Tien Yin

    2010-03-01

    Pathological myopia is the seventh leading cause of blindness. We introduce a framework based on PAMELA (PAthological Myopia dEtection through peripapilLary Atrophy) for the detection of pathological myopia from fundus images. The framework consists of a pre-processing stage which extracts a region of interest centered on the optic disc. Subsequently, three analysis modules focus on detecting specific visual indicators. The optic disc tilt ratio module gives a measure of the axial elongation of the eye through inference from the deformation of the optic disc. In the texturebased ROI assessment module, contextual knowledge is used to demarcate the ROI into four distinct, clinically-relevant zones in which information from an entropy transform of the ROI is analyzed and metrics generated. In particular, the preferential appearance of peripapillary atrophy (PPA) in the temporal zone compared to the nasal zone is utilized by calculating ratios of the metrics. The PPA detection module obtains an outer boundary through a level-set method, and subtracts this region against the optic disc boundary. Temporal and nasal zones are obtained from the remnants to generate associated hue and color values. The outputs of the three modules are used as in a SVM model to determine the presence of pathological myopia in a retinal fundus image. Using images from the Singapore Eye Research Institute, the proposed framework reported an optimized accuracy of 90% and a sensitivity and specificity of 0.85 and 0.95 respectively, indicating promise for the use of the proposed system as a screening tool for pathological myopia.

  8. Reading disc-based bioassays with standard computer drives.

    PubMed

    Yu, Hua-Zhong; Li, Yunchao; Ou, Lily M-L

    2013-02-19

    Traditional methods of disease diagnosis are both time-consuming and labor-intensive, and many tests require expensive instrumentation and trained professionals, which restricts their use to biomedical laboratories. Because patients can wait several days (even weeks) for the results, the consequences of delayed treatment could be disastrous. Therefore, affordable and simple point-of-care (POC) biosensor devices could fill a diagnostic niche in the clinic or even at home, as personal glucose meters do for diabetics. These devices would allow patients to check their own health conditions and enable physicians to make prompt treatment decisions, which could improve the chances for rapid recovery and cure. Compact discs (CDs) provide inexpensive substrate materials for the preparation of microarray biochips, and conventional computer drives/disc players can be adapted as precise optical reading devices for signal processing. Researchers can employ the polycarbonate (PC) base of a CD as an alternative substrate to glass slides or silicon wafers for the preparation of microanalytical devices. Using the characteristic optical phenomena occurring on the metal layer of a CD, researchers can develop biosensors based on advanced spectroscopic readout (interferometry or surface plasmon resonance). If researchers integrate microfluidic functions with CD mechanics, they can control fluid transfer through the spinning motion of the disc, leading to "lab-on-a-CD" devices. Over the last decade, our laboratory has focused on the construction of POC biosensor devices from off-the-shelf CDs or DVDs and standard computer drives. Besides the initial studies of the suitability of CDs for surface and materials chemistry research (fabrication of self-assembled monolayers and oxide nanostructures), we have demonstrated that an ordinary optical drive, without modification of either the hardware or the software driver, can function as the signal transducing element for reading disc

  9. Immediate effect of benzalkonium chloride in decongestant nasal spray on the human nasal mucosal temperature.

    PubMed

    Lindemann, J; Leiacker, R; Wiesmiller, K; Rettinger, G; Keck, T

    2004-08-01

    Benzalkonium chloride is a preservative commonly used in nasal decongestant sprays. It has been suggested that benzalkonium chloride may be harmful to the nasal mucosa. Decongestion with the vasoconstrictor xylometazoline containing benzalkonium chloride has been shown to cause a significant reduction of the nasal mucosal temperature. The purpose of the present study was to determine the short-term influence of xylometazoline nasal spray with and without benzalkonium chloride on the nasal mucosal temperature. Healthy volunteers (30) were included in the study. Fifteen volunteers received xylometazoline nasal spray (1.0 mg/mL) containing benzalkonium chloride (0.1 mg/mL) and 15 age-matched subjects, received xylometazoline nasal spray without benzalkonium chloride. Using a miniaturized thermocouple the septal mucosal temperature was continuously measured at defined intranasal detection sites before and after application of the nasal spray. The mucosal temperature values did not significantly differ between the group receiving xylometazoline containing benzalkonium chloride and the group receiving xylometazoline spray without benzalkonium chloride before and after decongestion (P > 0.05). In both study groups septal mucosal temperatures significantly decreased after decongestion (P < 0.05) because of a reduction of the nasal mucosal blood flow following vasoconstriction. This study indicates that benzalkonium chloride itself does not seem to influence nasal blood flow and nasal mucosal temperature in topical nasal decongestants.

  10. Nasal carriage of multi-drug resistant Panton-Valentine leucocidin-positive methicillin-resistant Staphylococcus aureus in children in Tripoli-Libya.

    PubMed

    Al-haddad, Omaima H; Zorgani, Abdulaziz; Ghenghesh, Khalifa Sifaw

    2014-04-01

    Methicillin-resistant Staphylococcus aureus (MRSA) colonized children are at an increased risk of developing infections than methicillin-sensitive S. aureus colonized children. Nasal specimens from inpatient children, mothers of inpatient children, healthcare workers, and outpatient children at Tripoli Children Hospital (TCH) were examined for MRSA by chromogenic MRSA ID medium. Susceptibility of MRSA isolates to antibiotics was determined by the disc diffusion method. The nasal carriage rate of MRSA among inpatient children (8.3%, 24 of 289), their mothers (11%, 22 of 200), and healthcare workers (12.4%, 22 of 178) was significantly higher than among outpatient children (2.2%, 2 of 91) (P < 0.05, P < 0.02, and P < 0.006, respectively). Of the examined MRSA isolates (N = 35) 10 (28.6%) were positive for Panton-Valentine leucocidin genes by polymerase chain reaction. Multidrug resistance was found in 24.3% (17 of 70) of MRSA isolates. Nasal carriage of multidrug-resistant Panton-Valentine leucocidin-positive MRSA is not uncommon among inpatient children and their mothers in Tripoli.

  11. Surgical management of nasal obstruction.

    PubMed

    Moche, Jason A; Palmer, Orville

    2012-05-01

    The proper evaluation of the patient with nasal obstruction relies on a comprehensive history and physical examination. Once the site of obstruction is accurately identified, the patient may benefit from a trial of medical management. At times however, the definitive treatment of nasal obstruction relies on surgical management. Recognizing the nasal septum, nasal valve, and turbinates as possible sites of obstruction and addressing them accordingly can dramatically improve a patient's nasal breathing. Conservative resection of septal cartilage, submucous reduction of the inferior turbinate, and structural grafting of the nasal valve when appropriate will provide the optimal improvement in nasal airflow and allow for the most stable results. Copyright © 2012. Published by Elsevier Inc.

  12. Snoring and Nasal Congestion

    MedlinePlus

    ... treat the various causes of nasal congestion include: Topical nasal steroid spray Topical nasal antihistamine spray Oral antibiotic (in case of ... include more than just the decrease in oxygen levels at night during the apnea episodes. They also ...

  13. Appearance of Keplerian discs orbiting Kerr superspinars

    NASA Astrophysics Data System (ADS)

    Stuchlík, Zdeněk; Schee, Jan

    2010-11-01

    We study optical phenomena related to the appearance of Keplerian accretion discs orbiting Kerr superspinars predicted by string theory. The superspinar exterior is described by standard Kerr naked singularity geometry breaking the black hole limit on the internal angular momentum (spin). We construct local photon escape cones for a variety of orbiting sources that enable us to determine the superspinars silhouette in the case of distant observers. We show that the superspinar silhouette depends strongly on the assumed edge where the external Kerr spacetime is joined to the internal spacetime governed by string theory and significantly differs from the black hole silhouette. The appearance of the accretion disc is strongly dependent on the value of the superspinar spin in both their shape and frequency shift profile. Apparent extension of the disc grows significantly with the growing spin, while the frequency shift grows with the descending spin. This behaviour differs substantially from the appearance of discs orbiting black holes enabling thus, at least in principle, to distinguish clearly the Kerr superspinars and black holes. In vicinity of a Kerr superspinar the non-escaped photons have to be separated to those captured by the superspinar and those being trapped in its strong gravitational field leading to self-illumination of the disc that could even influence its structure and cause self-reflection effect of radiation of the disc. The amount of trapped photons grows with descending superspinar spin. We thus can expect significant self-illumination effects in the field of Kerr superspinars with near-extreme spin a ~ 1.

  14. Topical nasal decongestant oxymetazoline (0.05%) provides relief of nasal symptoms for 12 hours.

    PubMed

    Druce, H M; Ramsey, D L; Karnati, S; Carr, A N

    2018-05-22

    Nasal congestion, often referred to as stuffy nose or blocked nose is one of the most prevalent and bothersome symptoms of an upper respiratory tract infection. Oxymetazoline, a widely used intranasal decongestant, offers fast symptom relief, but little is known about the duration of effect. The results of 2 randomized, double-blind, vehicle-controlled, single-dose, parallel, clinical studies (Study 1, n=67; Study 2, n=61) in which the efficacy of an oxymetazoline (0.05% Oxy) nasal spray in patients with acute coryzal rhinitis was assessed over a 12-hour time-period. Data were collected on both subjective relief of nasal congestion (6-point nasal congestion scale) and objective measures of nasal patency (anterior rhinomanometry) in both studies. A pooled study analysis showed statistically significant changes from baseline in subjective nasal congestion for 0.05% oxymetazoline and vehicle at each hourly time-point from Hour 1 through Hour 12 (marginally significant at Hour 11). An objective measure of nasal flow was statistically significant at each time-point up to 12 hours. Adverse events on either treatment were infrequent. The number of subjects who achieved an improvement in subjective nasal congestion scores of at least 1.0 was significantly higher in the Oxy group vs. vehicle at all hourly time-points on a 6-point nasal congestion scale. This study shows for the first time, that oxymetazoline provides both statistically significant and clinically meaningful relief of nasal congestion and improves nasal airflow for up to 12 hours following a single dose.

  15. Evaluation of nasal IgA secretion in normal subjects by nasal spray and aspiration.

    PubMed

    Fujimoto, Chisa; Kido, Hiroshi; Sawabuchi, Takako; Mizuno, Dai; Hayama, Masaki; Yanagawa, Hiroaki; Takeda, Noriaki

    2009-06-01

    Nasal washing (NW) is a popular method for collecting human nasal lavage fluid. However, for NW the subject must be trained, and the method is unsuitable for field studies on untrained subjects. To overcome this problem, we have developed an easy and painless method, a nasal spray and aspiration (NSA) method. This method is different from NW in that the nasal cavity is misted over with saline, and the nasal lavage fluid is aspirated from the nostrils through a silicon tube. First, nasal lavage fluid was obtained twice by NSA with an interval of a week between lavages to evaluate intraindividual variability, and the IgA and protein levels in the nasal lavage fluid were measured by enzyme-linked immunosorbent assay and bicinchoninic acid assay, respectively. Next, the IgA value determined by NSA was compared with that by NW in another 12 normal subjects 2 days after NSA. In 10 normal subjects, mean volume of saline sprayed into the nose was 0.46+/-0.15 ml (mean+/-S.D.). Mean volume of aspirated nasal lavage fluid containing both sprayed saline and nasal secretion was 0.44+/-0.37 ml. The mean IgA level/mg protein in the nasal lavage fluid determined by NSA was 112+/-18 microg/mg protein at the first and 99+/-20 at the second times of measurement, being highly reproducible. The mean value by NSA was 114+/-19 microg/mg protein, being almost the same as that by NW of 99+/-27. These findings suggest that the IgA level/mg protein in nasal lavage fluid determined by NSA instead of NW might be useful for assessing the variability of nasal IgA secretion.

  16. Perceiving nasal patency through mucosal cooling rather than air temperature or nasal resistance.

    PubMed

    Zhao, Kai; Blacker, Kara; Luo, Yuehao; Bryant, Bruce; Jiang, Jianbo

    2011-01-01

    Adequate perception of nasal airflow (i.e., nasal patency) is an important consideration for patients with nasal sinus diseases. The perception of a lack of nasal patency becomes the primary symptom that drives these patients to seek medical treatment. However, clinical assessment of nasal patency remains a challenge because we lack objective measurements that correlate well with what patients perceive. The current study examined factors that may influence perceived patency, including air temperature, humidity, mucosal cooling, nasal resistance, and trigeminal sensitivity. Forty-four healthy subjects rated nasal patency while sampling air from three facial exposure boxes that were ventilated with untreated room air, cold air, and dry air, respectively. In all conditions, air temperature and relative humidity inside each box were recorded with sensors connected to a computer. Nasal resistance and minimum airway cross-sectional area (MCA) were measured using rhinomanometry and acoustic rhinometry, respectively. General trigeminal sensitivity was assessed through lateralization thresholds to butanol. No significant correlation was found between perceived patency and nasal resistance or MCA. In contrast, air temperature, humidity, and butanol threshold combined significantly contributed to the ratings of patency, with mucosal cooling (heat loss) being the most heavily weighted predictor. Air humidity significantly influences perceived patency, suggesting that mucosal cooling rather than air temperature alone provides the trigeminal sensation that results in perception of patency. The dynamic cooling between the airstream and the mucosal wall may be quantified experimentally or computationally and could potentially lead to a new clinical evaluation tool.

  17. Functional anatomy of the nasal bones and adjacent structures. Consequences for nasal surgery.

    PubMed

    Popko, M; Verlinde-Schellekens, S A M W; Huizing, E H; Bleys, R L A W

    2018-03-01

    The periosteum of the nasal bones, the periosteal-perichondrial nasal envelope, and the cartilaginous support of the bony vault were studied in serial coronal sections of four human cadaver noses. To differentiate between the various tissue components, the sections were stained according to Mallory-Cason and Verhoeff-Van Gieson stain. The results demonstrated: 1. the presence of clearly distinguishable layers of the periosteum covering the nasal bones; 2. the presence of a continuous periosteal-perichondrial covering of the bony and cartilaginous nasal vaults; 3. the way the cartilaginous support of the bony vault is constructed. The findings described in the present study may have clinical relevance in nasal surgery.

  18. Three-dimensional choroidal segmentation in spectral OCT volumes using optic disc prior information

    NASA Astrophysics Data System (ADS)

    Hu, Zhihong; Girkin, Christopher A.; Hariri, Amirhossein; Sadda, SriniVas R.

    2016-03-01

    Recently, much attention has been focused on determining the role of the peripapillary choroid - the layer between the outer retinal pigment epithelium (RPE)/Bruchs membrane (BM) and choroid-sclera (C-S) junction, whether primary or secondary in the pathogenesis of glaucoma. However, the automated choroidal segmentation in spectral-domain optical coherence tomography (SD-OCT) images of optic nerve head (ONH) has not been reported probably due to the fact that the presence of the BM opening (BMO, corresponding to the optic disc) can deflect the choroidal segmentation from its correct position. The purpose of this study is to develop a 3D graph-based approach to identify the 3D choroidal layer in ONH-centered SD-OCT images using the BMO prior information. More specifically, an initial 3D choroidal segmentation was first performed using the 3D graph search algorithm. Note that varying surface interaction constraints based on the choroidal morphological model were applied. To assist the choroidal segmentation, two other surfaces of internal limiting membrane and innerouter segment junction were also segmented. Based on the segmented layer between the RPE/BM and C-S junction, a 2D projection map was created. The BMO in the projection map was detected by a 2D graph search. The pre-defined BMO information was then incorporated into the surface interaction constraints of the 3D graph search to obtain more accurate choroidal segmentation. Twenty SD-OCT images from 20 healthy subjects were used. The mean differences of the choroidal borders between the algorithm and manual segmentation were at a sub-voxel level, indicating a high level segmentation accuracy.

  19. Optical sensing system based on wireless paired emitter detector diode device and ionogels for lab-on-a-disc water quality analysis.

    PubMed

    Czugala, Monika; Gorkin, Robert; Phelan, Thomas; Gaughran, Jennifer; Curto, Vincenzo Fabio; Ducrée, Jens; Diamond, Dermot; Benito-Lopez, Fernando

    2012-12-07

    This work describes the first use of a wireless paired emitter detector diode device (PEDD) as an optical sensor for water quality monitoring in a lab-on-a-disc device. The microfluidic platform, based on an ionogel sensing area combined with a low-cost optical sensor, is applied for quantitative pH and qualitative turbidity monitoring of water samples at point-of-need. The autonomous capabilities of the PEDD system, combined with the portability and wireless communication of the full device, provide the flexibility needed for on-site water testing. Water samples from local fresh and brackish sources were successfully analysed using the device, showing very good correlation with standard bench-top systems.

  20. Fourier-domain optical coherence tomography and adaptive optics reveal nerve fiber layer loss and photoreceptor changes in a patient with optic nerve drusen.

    PubMed

    Choi, Stacey S; Zawadzki, Robert J; Greiner, Mark A; Werner, John S; Keltner, John L

    2008-06-01

    New technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic disc drusen. Using Stratus and Fourier domain (FD) optical coherence tomography (OCT) and adaptive optics (AO) through a flood-illuminated fundus camera, we studied the retinas of a patient with long-standing optic disc drusen and acute visual loss at high altitude attributed to ischemic optic neuropathy. Stratus OCT and FD-OCT confirmed severe thinning of the retinal nerve fiber layer (RNFL). FD-OCT revealed disturbances in the photoreceptor layer heretofore not described in optic disc drusen patients. AO confirmed the FD-OCT findings in the photoreceptor layer and also showed reduced cone density at retinal locations associated with reduced visual sensitivity. Based on this study, changes occur not only in the RNFL but also in the photoreceptor layer in optic nerve drusen complicated by ischemic optic neuropathy. This is the first reported application of FD-OCT and the AO to this condition. Such new imaging technology may in the future allow monitoring of disease progression more precisely and accurately.

  1. Prominent Optic Disc Featured in Inherited Retinopathy.

    PubMed

    Todorova, M G; Bojinova, R I; Valmaggia, C; Schorderet, D F

    2017-04-01

    Background We investigated the relationship between prominent optic disc (POD) and inherited retinal dystrophy (IRD). Patients and Methods A cross-sectional consecutive study was performed in 10 children and 11 adults of 7 non-related families. We performed clinical phenotyping, including a detailed examination, fundus autofluorescence, and colour fundus and OCT imaging. Genetic testing was subsequently performed for all family members presenting retinal pathology. Results In 4 members of a 3-generation family, hyperfluorescent deposits on the surface of POD were related to a p.(L224M) heterozygous mutation in BEST1 . In the second family, one member presented deposits located on the surface on hyperaemic OD and a compound p.(R141H);(A195V) mutation in BEST1 . In the third family, POD was observed in father and child with early onset cone-rod dystrophy and a novel autosomal recessive p.(W31*) homozygous mutation in ABCA4 . In the fourth family, POD with "mulberry-like" deposits and attenuated vessels were observed in a 7-year old girl, with a mutation in USH1A , and with early onset rod-cone dystrophy, associated with hearing loss. In the fifth family, blurry OD with tortuous vessels was observed in 4 consanguineous female carriers and a hemizygous boy with a p.(R200H) mutation in the X-linked retinoschisis RS1 . In the sixth family, a mother and her son were both affected with POD and attenuated peripapillary vessels, and presented with a p.(Y836C) heterozygous mutation in TOPORS , thus confirming autosomal dominant RP. In the seventh family, in 3 family members with POD, compound p.(L541P;A1038 V);(G1961E) mutations in ABCA4 confirmed the diagnosis of Stargardt disease. Conclusions A variety of OD findings are found in a genetically heterogeneous group of IRDs. In the presence of POD, an inherited progressive photoreceptor disease should be ruled out. Georg Thieme Verlag KG Stuttgart · New York.

  2. Comparison between Perceptual Assessments of Nasality and Nasalance Scores

    ERIC Educational Resources Information Center

    Brunnegard, Karin; Lohmander, Anette; van Doorn, Jan

    2012-01-01

    Background: There are different reports of the usefulness of the Nasometer[TM] as a complement to listening, often as correlation calculations between listening and nasalance measurements. Differences between findings have been attributed to listener experience and types of speech stimuli. Aims: To compare nasalance scores from the Nasometer with…

  3. Perceiving Nasal Patency through Mucosal Cooling Rather than Air Temperature or Nasal Resistance

    PubMed Central

    Zhao, Kai; Blacker, Kara; Luo, Yuehao; Bryant, Bruce; Jiang, Jianbo

    2011-01-01

    Adequate perception of nasal airflow (i.e., nasal patency) is an important consideration for patients with nasal sinus diseases. The perception of a lack of nasal patency becomes the primary symptom that drives these patients to seek medical treatment. However, clinical assessment of nasal patency remains a challenge because we lack objective measurements that correlate well with what patients perceive.The current study examined factors that may influence perceived patency, including air temperature, humidity, mucosal cooling, nasal resistance, and trigeminal sensitivity. Forty-four healthy subjects rated nasal patency while sampling air from three facial exposure boxes that were ventilated with untreated room air, cold air, and dry air, respectively. In all conditions, air temperature and relative humidity inside each box were recorded with sensors connected to a computer. Nasal resistance and minimum airway cross-sectional area (MCA) were measured using rhinomanometry and acoustic rhinometry, respectively. General trigeminal sensitivity was assessed through lateralization thresholds to butanol. No significant correlation was found between perceived patency and nasal resistance or MCA. In contrast, air temperature, humidity, and butanol threshold combined significantly contributed to the ratings of patency, with mucosal cooling (heat loss) being the most heavily weighted predictor. Air humidity significantly influences perceived patency, suggesting that mucosal cooling rather than air temperature alone provides the trigeminal sensation that results in perception of patency. The dynamic cooling between the airstream and the mucosal wall may be quantified experimentally or computationally and could potentially lead to a new clinical evaluation tool. PMID:22022361

  4. Heidelberg Retina Tomography Analysis in Optic Disks with Anatomic Particularities

    PubMed Central

    Alexandrescu, C; Pascu, R; Ilinca, R; Popescu, V; Ciuluvica, R; Voinea, L; Celea, C

    2010-01-01

    Due to its objectivity, reproducibility and predictive value confirmed by many large scale statistical clinical studies, Heidelberg Retina Tomography has become one of the most used computerized image analysis of the optic disc in glaucoma. It has been signaled, though, that the diagnostic value of Moorfieds Regression Analyses and Glaucoma Probability Score decreases when analyzing optic discs with extreme sizes. The number of false positive results increases in cases of megalopapilllae and the number of false negative results increases in cases of small size optic discs. The present paper is a review of the aspects one should take into account when analyzing a HRT result of an optic disc with anatomic particularities. PMID:21254731

  5. Comparison of Early-period Results of Nasal Splint and Merocel Nasal Packs in Septoplasty

    PubMed Central

    Bingöl, Fatih; Budak, Ali; Şimşek, Eda; Kılıç, Korhan; Bingöl, Buket Özel

    2017-01-01

    Objective Several types of nasal packs are used postoperatively in septoplasty. In this study, we compared two commonly used nasal packing materials, the intranasal septal splint with airway and Merocel tampon, in terms of pain, bleeding, nasal obstruction, eating difficulties, discomfort in sleep, and pain and bleeding during removal of packing in the early period. Methods The study group included 60 patients undergoing septoplasty. Patients were divided into two groups (n=30 in each group). An intranasal splint with airway was used for the patients in the first group after septoplasty, while Merocel nasal packing was used for the second group. Patients were investigated in terms of seven different factors - pain, bleeding while the tampon was in place, nasal obstruction, eating difficulties, night sleep, pain during removal of the nasal packing, and bleeding after removal of packing. Results There was no statistically significant difference between the groups in terms of pain 24 hours after operation (p=0.05), while visual analog scale (VAS) scores for nasal obstruction, night sleep, eating difficulties, and pain during packing removal were lower in the nasal splint group with a statistically significant difference (p<0.05). There was no statistically significant difference between the groups in terms of postoperative bleeding (p=0.23). Significantly less bleeding occurred during removal of the packing in the nasal splint group (p<0.05). Conclusion Our study indicates that the nasal splint was more comfortable and effective in terms of causing lesser bleeding and pain during removal of packing. PMID:29392071

  6. [Research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration].

    PubMed

    Liang, Hang; Deng, Xiangyu; Shao, Zengwu

    2017-10-01

    To summarize the research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration and deduce the therapeutic potential of endogenous repair for intervertebral disc degeneration. The original articles about intervertebral disc endogenous stem cells for intervertebral disc regeneration were extensively reviewed; the reparative potential in vivo and the extraction and identification in vitro of intervertebral disc endogenous stem cells were analyzed; the prospect of endogenous stem cells for intervertebral disc regeneration was predicted. Stem cell niche present in the intervertebral discs, from which stem cells migrate to injured tissues and contribute to tissues regeneration under certain specific microenvironment. Moreover, the migration of stem cells is regulated by chemokines system. Tissue specific progenitor cells have been identified and successfully extracted and isolated. The findings provide the basis for biological therapy of intervertebral disc endogenous stem cells. Intervertebral disc endogenous stem cells play a crucial role in intervertebral disc regeneration. Therapeutic strategy of intervertebral disc endogenous stem cells is proven to be a promising biological approach for intervertebral disc regeneration.

  7. Nasalance measures in Cantonese-speaking women.

    PubMed

    Whitehill, T L

    2001-03-01

    To establish and evaluate stimulus materials for nasalance measurement in Cantonese speakers, to provide normative data for Cantonese-speaking women, and to evaluate session-to-session reliability of nasalance measures. One hundred forty-one Cantonese-speaking women with normal resonance who were students in the Department of Speech and Hearing Sciences, University of Hong Kong. Participants read aloud four speech stimuli: oral sentences, nasal sentences, an oral paragraph (similar to the Zoo Passage), and an oral-nasal paragraph (similar to the Rainbow Passage). Data were collected and analyzed using the Kay Nasometer 6200. Data collection was repeated for a subgroup of speakers (n = 28) on a separate day. Nasalance materials were evaluated by using statistical tests of difference and correlation. Group mean (standard deviation) nasalance scores for oral sentences, nasal sentences, oral paragraph, and oral-nasal paragraph were 16.79 (5.99), 55.67 (7.38), 13.68 (7.16), and 35.46 (6.22), respectively. There was a significant difference in mean nasalance scores for oral versus nasal materials. Correlations between stimuli were as expected, ranging from 0.43 to 0.91. Session-to-session reliability was within 5 points for over 95% of speakers for the oral stimuli but for less than 76% of speakers for the nasal and oral-nasal stimuli. Standard nasalance materials have been developed for Cantonese, and normative data have been established for Cantonese women. Evaluation of materials indicated acceptable differentiation between oral and nasal materials. Two stimuli (nasal sentences and oral paragraph) are recommended for future use. Comparison with findings from other languages showed similarities in scores; possible language-specific differences are discussed. Session-to-session reliability was poorer for nasal than oral stimuli.

  8. Nasal septal hematoma

    MedlinePlus

    ... medlineplus.gov/ency/article/001292.htm Nasal septal hematoma To use the sharing features on this page, please enable JavaScript. A nasal septal hematoma is a collection of blood within the septum ...

  9. Same Noses, Different Nasalance Scores: Data from Normal Subjects and Cleft Palate Speakers for Three Systems for Nasalance Analysis

    ERIC Educational Resources Information Center

    Bressmann, Tim; Klaiman, Paula; Fischbach, Simone

    2006-01-01

    Nasalance scores from the Nasometer, the NasalView and the OroNasal System were compared. The data was collected from 50 normal participants and 19 hypernasal patients with cleft palate. The Nasometer had the lowest nasalance scores for the non-nasal Zoo Passage and that the OroNasal System had the lowest nasalance scores for the Nasal Sentences.…

  10. Nasal hydropulsion.

    PubMed

    Elizabeth, Ashbaugh

    2013-08-01

    Intranasal tumors of dogs and cats pose a diagnostic and therapeutic challenge for the small animal practitioner. A simplified flushing technique to biopsy and debulk nasal tumors, that often results in immediate clinical relief for the patient is described. This technique can also be utilized to remove nasal foreign bodies. © 2013 Elsevier Inc. All rights reserved.

  11. Ipratropium Nasal Spray

    MedlinePlus

    ... follow these steps: Remove the clear plastic dust cap and the safety clip from the nasal spray ... the other nostril. Replace the clear plastic dust cap and safety clip. If the nasal tip becomes ...

  12. Nasal fracture - aftercare

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000554.htm Nasal fracture - aftercare To use the sharing features on this ... that gives your nose its shape. A nasal fracture occurs when the bony part of your nose ...

  13. Nasal Wash Treatment

    MedlinePlus

    ... Guidelines Wash your hands. Make the nasal wash solution. Do not use tap water for the nasal ... Whichever water you use to make the saline solution, replace container or water at least weekly. To ...

  14. Beclomethasone Nasal Spray

    MedlinePlus

    ... the lining of the nose) after nasal polyp removal surgery. Beclomethasone nasal spray should not be used ... room temperature and away from excess heat and moisture (not in the bathroom).Unneeded medications should be ...

  15. Nasal Harmony in Aguaruna.

    ERIC Educational Resources Information Center

    Moon, Gui-Sun

    A discussion of the nasal harmony of Aguaruna, a language of the Jivaroan family in South America, approaches the subject from the viewpoint of generative phonology. This theory of phonology proposes an underlying nasal consonant, later deleted, that accounts for vowel nasalization. Complex rules that suppose a complex system of vowel and…

  16. The Palenque Project: A Process of Design and Development as Research in the Evolution of an Optical Disc Prototype for Children. Technical Report No. 47.

    ERIC Educational Resources Information Center

    Wilson, Kathleen S.; Tally, William J.

    This report describes the Palenque Project, a highly interactive, multimedia, optical disc research prototype which was developed for home use and tested by observing 25 children in the 9 to 14 year age range and their families and 8 12-year-olds in pairs. It is noted that the project was intended to create a rich, multimedia database environment…

  17. External Nasal Neuralgia: A Neuropathic Pain Within the Territory of the External Nasal Nerve.

    PubMed

    García-Moreno, Héctor; Aledo-Serrano, Ángel; Gimeno-Hernández, Jesús; Cuadrado, María-Luz

    2015-10-01

    Nasal pain is a challenging diagnosis and very little has been reported in the neurological literature. The nose is a sophisticated structure regarding its innervation, which is supplied by the first and second divisions of the trigeminal nerve. Painful cranial neuropathies are an important group in the differential diagnosis, although they have been described only scarcely. Here, we report a case that can conform a non-traumatic external nasal nerve neuralgia. A 76-year-old woman was referred to our office due to pain in her left nose. She was suffering from daily excruciating attacks, which were strictly limited to the territory supplied by her left external nasal nerve (left ala nasi and apex nasi). She denied previous traumatisms and the ancillary tests did not yield any underlying pathology. An anesthetic blockade of her left external nasal nerve achieved a marked reduction of the number of episodes as well as their intensity. External nasal neuralgia seems a specific neuralgia causing nasal pain. Anesthetic blockades of the external nasal nerve may be a valid treatment for this condition. © 2015 American Headache Society.

  18. Engineered disc-like angle-ply structures for intervertebral disc replacement.

    PubMed

    Nerurkar, Nandan L; Sen, Sounok; Huang, Alice H; Elliott, Dawn M; Mauck, Robert L

    2010-04-15

    To develop a construction algorithm in which electrospun nanofibrous scaffolds are coupled with a biocompatible hydrogel to engineer a mesenchymal stem cell (MSC)-based disc replacement. To engineer a disc-like angle-ply structure (DAPS) that replicates the multiscale architecture of the intervertebral disc. Successful engineering of a replacement for the intervertebral disc requires replication of its mechanical function and anatomic form. Despite many attempts to engineer a replacement for ailing and degenerated discs, no prior study has replicated the multiscale hierarchical architecture of the native disc, and very few have assessed the mechanical function of formed neo-tissues. A new algorithm for the construction of a disc analogue was developed, using agarose to form a central nucleus pulposus (NP) and oriented electrospun nanofibrous scaffolds to form the anulus fibrosus region (AF). Bovine MSCs were seeded into both regions and biochemical, histologic, and mechanical maturation were evaluated with in vitro culture. We show that mechanical testing in compression and torsion, loading methods commonly used to assess disc mechanics, reveal equilibrium and time-dependent behaviors that are qualitatively similar to native tissue, although lesser in magnitude. Further, we demonstrate that cells seeded into both AF and NP regions adopt distinct morphologies that mirror those seen in native tissue, and that, in the AF region, this ordered community of cells deposit matrix that is organized in an angle-ply configuration. Finally, constructs demonstrate functional development with long-term in vitro culture. These findings provide a new approach for disc tissue engineering that replicates multi-scale form and function of the intervertebral disc, providing a foundation from which to build a multi-scale, biologic, anatomically and hierarchically relevant composite disc analogue for eventual disc replacement.

  19. The relationship between quantitative measures of disc height and disc signal intensity with Pfirrmann score of disc degeneration.

    PubMed

    Salamat, Sara; Hutchings, John; Kwong, Clemens; Magnussen, John; Hancock, Mark J

    2016-01-01

    To assess the relationship between quantitative measures of disc height and signal intensity with the Pfirrmann disc degeneration scoring system and to test the inter-rater reliability of the quantitative measures. Participants were 76 people who had recently recovered from their last episode of acute low back pain and underwent MRI scan on a single 3T machine. At all 380 lumbar discs, quantitative measures of disc height and signal intensity were made by 2 independent raters and compared to Pfirrmann scores from a single radiologist. For quantitative measures of disc height and signal intensity a "raw" score and 2 adjusted ratios were calculated and the relationship with Pfirrmann scores was assessed. The inter-tester reliability of quantitative measures was also investigated. There was a strong linear relationship between quantitative disc signal intensity and Pfirrmann scores for grades 1-4, but not for grades 4 and 5. For disc height only, Pfirrmann grade 5 had significantly reduced disc height compared to all other grades. Results were similar regardless of whether raw or adjusted scores were used. Inter-rater reliability for the quantitative measures was excellent (ICC > 0.97). Quantitative measures of disc signal intensity were strongly related to Pfirrmann scores from grade 1 to 4; however disc height only differentiated between grade 4 and 5 Pfirrmann scores. Using adjusted ratios for quantitative measures of disc height or signal intensity did not significantly alter the relationship with Pfirrmann scores.

  20. Does rhinoplasty improve nasal breathing?

    PubMed

    Xavier, Rui

    2010-08-01

    Rhinoplasty is a surgical procedure that aims to improve nasal aesthetics and nasal breathing. The aesthetic improvement of the nose is usually judged subjectively by the patient and the surgeon, but the degree of improvement of nasal obstruction is difficult to assess by clinical examination only. The measurement of peak nasal inspiratory flow (PNIF) is a reliable tool that has been shown to correlate with other objective methods of assessing nasal breathing and with patients' symptoms of nasal obstruction. Twenty-three consecutive patients undergoing rhinoplasty have been evaluated by measurement of PNIF before and after surgery. All but three patients had an increase in PNIF after surgery. The mean preoperative PNIF was 86.5 L/min and the mean postoperative PNIF was 123.0 L/min ( P < 0.001). Not surprisingly, the greatest improvement in PNIF was achieved when bilateral spreader grafts were used. This study suggests that rhinoplasty does improve nasal breathing. (c) Thieme Medical Publishers

  1. Management of nasal septal perforation using silicone nasal septal button

    PubMed Central

    Mullace, M; Gorini, E; Sbrocca, M; Artesi, L; Mevio, N

    2006-01-01

    Summary Nasal septal perforation may present with various symptoms: epistaxis, crusting, secondary infection, whistling and nasal obstruction. Perforation may be treated by conservative pharmacological treatment or closed by surgical approach. A useful alternative is mechanical obturation, achieved inserting a prosthesis. The present report refers to a study on 15 patients (10 male, 5 female, mean age 38.5 years) treated by insertion of a one-piece or two-piece silicone septal button (Xomed). In the follow-up period, insertion of the nasal button reduced epistaxis, eliminated whistling during inspiration, and reduced nasal obstruction and crusting around the margin of the perforation. Contraindications are presence of acute infection with osteitis, chronic septal disease (Wegener), neoplasia and extremely large perforations. The latest buttons appear to be superior to the conventional type on account of plasticity and adaptability which offer greater conformity to the septum. This study also reveals that the new septal button is well tolerated by patients. PMID:18236638

  2. Complications of Nasal Bone Fractures.

    PubMed

    Hwang, Kun; Yeom, Seung Han; Hwang, Suk Hyun

    2017-05-01

    The aim of this study was to perform a systematic review of the treatment of nasal bone fractures. The search terms ("nasal bone fracture" AND complication) and ("nasal bone fracture" AND [anosmia OR olfaction OR olfactory nerve OR smell]) and (anosmia AND ["nasal preparation" OR "nasal antiseptics"]) were used to search PubMed and SCOPUS. Of the 500 titles, 40 full papers were reviewed. One paper was excluded, and 3 mined papers were added. Ultimately, 12 papers were analyzed. The overall deformity rate was 10.4% ± 4.8%. No significant differences were found between patients who underwent closed reduction (14.7% ± 7.3%) and those who underwent open reduction (9.4% ± 4.4%), between those who underwent local anesthesia (5.8% ± 4.5%), and those who underwent general anesthesia (8.8% ± 3.8%), or between those who received timely treatment (5.7%) and those whose treatment was delayed (9.0%). Septal deviation occurred in 10.0% of patients as a sequela of nasal bone fracture. The nasal obstruction rate was 10.5% ± 5.3%. Fewer patients of nasal obstruction occurred in the open reduction patients (6.9% ± 4.4%) than in the closed reduction patients (15.2%). One patient of epiphora and 1 patient of diplopia were reportedAmong the 77 patients with nasal bone fractures, 29 (37.7% ± 11.3%) complained of olfactory disturbances. No significant associations were found between the type of fracture and the presence of olfactory disturbances. It is recommended for providers to explain to patients that approximately one-tenth of nasal bone fractures exhibit deformity, septal deviation, or nasal obstruction after surgery. Surgeons should take considerable care to avoid the olfactory mucosa during reduction surgery.

  3. Changes in nasal airflow and heat transfer correlate with symptom improvement after surgery for nasal obstruction.

    PubMed

    Kimbell, J S; Frank, D O; Laud, Purushottam; Garcia, G J M; Rhee, J S

    2013-10-18

    Surgeries to correct nasal airway obstruction (NAO) often have less than desirable outcomes, partly due to the absence of an objective tool to select the most appropriate surgical approach for each patient. Computational fluid dynamics (CFD) models can be used to investigate nasal airflow, but variables need to be identified that can detect surgical changes and correlate with patient symptoms. CFD models were constructed from pre- and post-surgery computed tomography scans for 10 NAO patients showing no evidence of nasal cycling. Steady-state inspiratory airflow, nasal resistance, wall shear stress, and heat flux were computed for the main nasal cavity from nostrils to posterior nasal septum both bilaterally and unilaterally. Paired t-tests indicated that all CFD variables were significantly changed by surgery when calculated on the most obstructed side, and that airflow, nasal resistance, and heat flux were significantly changed bilaterally as well. Moderate linear correlations with patient-reported symptoms were found for airflow, heat flux, unilateral allocation of airflow, and unilateral nasal resistance as a fraction of bilateral nasal resistance when calculated on the most obstructed nasal side, suggesting that these variables may be useful for evaluating the efficacy of nasal surgery objectively. Similarity in the strengths of these correlations suggests that patient-reported symptoms may represent a constellation of effects and that these variables should be tracked concurrently during future virtual surgery planning. © 2013 Elsevier Ltd. All rights reserved.

  4. Effect of Deviated Nasal Septum Type on Nasal Mucociliary Clearance, Olfactory Function, Quality of Life, and Efficiency of Nasal Surgery.

    PubMed

    Berkiten, Güler; Kumral, Tolgar Lütfi; Saltürk, Ziya; Atar, Yavuz; Yildirim, Güven; Uyar, Yavuz; Aydoğdu, Imran; Arslanoğlu, Ahmet

    2016-07-01

    The aim of this study was to analyze the influence of deviated nasal septum (DNS) type on nasal mucociliary clearance, quality of life (QoL), olfactory function, and efficiency of nasal surgery (septoplasty with or without inferior turbinate reduction and partial middle turbinectomy). Fifty patients (20 females and 30 males) with septal deviation were included in the study and were divided into 6 groups according to deviation type after examination by nasal endoscopy and paranasal computed tomography. The saccharin clearance test to evaluate the nasal mucociliary clearance time, Connecticut Chemosensory Clinical Research Center smell test for olfactory function, and sinonasal outcome test-22 (SNOT-22) for patient satisfaction were applied preoperatively and postoperatively at the sixth week after surgery. Nasal mucociliary clearance, smell, and SNOT-22 scores were measured before surgery and at the sixth week following surgery. No significant difference was found in olfactory and SNOT-22 scores for any of the DNS types (both convex and concave sides) (P > 0.05). In addition, there was no difference in the saccharin clearance time (SCT) of the concave and convex sides (P > 0.05). According to the DNS type, the mean SCT of the convex sides showed no difference, but that of the concave sides showed a difference in types 3, 4, 5, and 6. These types had a prolonged SCT (P < 0.05). Olfactory scores revealed no difference postoperatively in types 5 and 6 but were decreased significantly in types 1 to 4 (P < 0.05). There was no significant difference in the healing of both the mucociliary clearance (MCC) and olfactory functions. SNOT-22 results showed a significant decrease in type 3. All DNS types disturb the QoL regarding nasal MCC and olfaction functions. MCC values, olfactory function, and QoL scores are similar among the DNS types. Both sides of the DNS types affect the MCC scores symmetrically. Septal surgery improves olfaction function and QoL at the

  5. Resolving the disc-halo degeneracy - I: a look at NGC 628

    NASA Astrophysics Data System (ADS)

    Aniyan, S.; Freeman, K. C.; Arnaboldi, M.; Gerhard, O. E.; Coccato, L.; Fabricius, M.; Kuijken, K.; Merrifield, M.; Ponomareva, A. A.

    2018-05-01

    The decomposition of the rotation curve of galaxies into contribution from the disc and dark halo remains uncertain and depends on the adopted mass-to-light ratio (M/L) of the disc. Given the vertical velocity dispersion of stars and disc scale height, the disc surface mass density and hence the M/L can be estimated. We address a conceptual problem with previous measurements of the scale height and dispersion. When using this method, the dispersion and scale height must refer to the same population of stars. The scale height is obtained from near-infrared (IR) studies of edge-on galaxies and is weighted towards older kinematically hotter stars, whereas the dispersion obtained from integrated light in the optical bands includes stars of all ages. We aim to extract the dispersion for the hotter stars, so that it can then be used with the correct scale height to obtain the disc surface mass density. We use a sample of planetary nebulae (PNe) as dynamical tracers in the face-on galaxy NGC 628. We extract two different dispersions from its velocity histogram - representing the older and younger PNe. We also present complementary stellar absorption spectra in the inner regions of this galaxy and use a direct pixel fitting technique to extract the two components. Our analysis concludes that previous studies, which do not take account of the young disc, underestimate the disc surface mass density by a factor of ˜2. This is sufficient to make a maximal disc for NGC 628 appear like a submaximal disc.

  6. Cosmetic and Functional Nasal Deformities

    MedlinePlus

    ... nasal complaints. Nasal deformity can be categorized as “cosmetic” or “functional.” Cosmetic deformity of the nose results in a less ... taste , nose bleeds and/or recurrent sinusitis . A cosmetic or functional nasal deformity may occur secondary to ...

  7. Cosmetic rostral nasal reconstruction after nasal planum and premaxilla resection: technique and results in two dogs.

    PubMed

    Gallegos, Javier; Schmiedt, Chad W; McAnulty, Jonathan F

    2007-10-01

    To describe a novel reconstructive technique after nasal planum and premaxilla resection. Case report. Dogs (n=2) with squamous cell carcinoma (SCC) of the nasal planum. A 9-year-old neutered female Labrador retriever (dog 1) and an 11-year-old neutered male Golden retriever (dog 2) had resection of the nasal planum and premaxilla for treatment of locally invasive SCC. Reconstruction of a nasal planum facsimile was based on use of the nonhaired pigmented margins of bilateral labial mucocutaneous rotation-advancement flaps. Reconstruction of the premaxilla by construction of a nasal planum facsimile resulted in uncomplicated wound healing and improved cosmesis. There was no tumor recurrence at 1290 (dog 1) and 210 (dog 2) days after surgery. Reconstruction of a nasal planum facsimile was successfully performed without complications in 2 dogs with high owner satisfaction with cosmetic appearance. This technique represents a significant advancement in surgical cosmetic outcome, may potentially reduce postoperative complications, and should be considered for dogs requiring nasal reconstruction after nasal planum resection with premaxillectomy.

  8. Smart Polymers in Nasal Drug Delivery

    PubMed Central

    Chonkar, Ankita; Nayak, Usha; Udupa, N.

    2015-01-01

    Nasal drug delivery has now been recognized as a promising route for drug delivery due to its capability of transporting a drug to systemic circulation and central nervous system. Though nasal mucosa offers improved bioavailability and quick onset of action of the drug, main disadvantage associated with nasal drug delivery is mucocilliary clearance due to which drug particles get cleared from the nose before complete absorption through nasal mucosa. Therefore, mucoadhesive polymeric approach can be successfully used to enhance the retention of the drug on nasal mucosal surface. Here, some of the aspects of the stimuli responsive polymers have been discussed which possess liquid state at the room temperature and in response to nasal temperature, pH and ions present in mucous, can undergo in situ gelation in nasal cavity. In this review, several temperature responsive, pH responsive and ion responsive polymers used in nasal delivery, their gelling mechanisms have been discussed. Smart polymers not only able to enhance the retention of the drug in nasal cavity but also provide controlled release, ease of administration, enhanced permeation of the drug and protection of the drug from mucosal enzymes. Thus smart polymeric approach can be effectively used for nasal delivery of peptide drugs, central nervous system dugs and hormones. PMID:26664051

  9. Risk factors for nasal malignancies in German men: the South-German Nasal cancer study.

    PubMed

    Greiser, Eberhard M; Greiser, Karin Halina; Ahrens, Wolfgang; Hagen, Rudolf; Lazszig, Roland; Maier, Heinz; Schick, Bernhard; Zenner, Hans Peter

    2012-11-06

    There are few studies of the effects of nasal snuff and environmental factors on the risk of nasal cancer. This study aimed to investigate the impact of using nasal snuff and of other risk factors on the risk of nasal cancer in German men. A population-based case-control study was conducted in the German Federal States of Bavaria and Baden-Württemberg. Tumor registries and ear, nose and throat departments provided access to patients born in 1926 or later. Telephone interviews were conducted with 427 cases (mean age 62.1 years) and 2.401 population-based controls (mean age 60.8 years). Ever-use of nasal snuff was associated with an odds ratio (OR) for nasal cancer of 1.45 (95% confidence interval [CI] 0.88-2.38) in the total study population, whereas OR in smokers was 2.01 (95% CI 1.00-4.02) and in never smokers was 1.10 (95% CI 0.43-2.80). The OR in ever-smokers vs. never-smokers was 1.60 (95% CI 1.24-2.07), with an OR of 1.06 (95% CI 1.05-1.07) per pack-year smoked, and the risk was significantly decreased after quitting smoking. Exposure to hardwood dust for at least 1 year resulted in an OR of 2.33 (95% CI 1.40-3.91) in the total population, which was further increased in never-smokers (OR 4.89, 95% CI 1.92-12.49) in analyses stratified by smoking status. The OR for nasal cancer after exposure to organic solvents for at least 1 year was 1.53 (1.17-2.01). Ever-use of nasal sprays/nasal lavage for at least 1 month rendered an OR of 1.59 (1.04-2.44). The OR after use of insecticides in homes was 1.48 (95% CI 1.04-2.11). Smoking and exposure to hardwood dust were confirmed as risk factors for nasal carcinoma. There is evidence that exposure to organic solvents, and in-house use of insecticides could represent novel risk factors. Exposure to asbestos and use of nasal snuff were risk factors in smokers only.

  10. Nasal obstruction and human communication.

    PubMed

    Malinoff, R; Moreno, C

    1989-04-01

    Nasal obstruction may cause a variety of communication disorders, particularly in children. The effects of nasal obstruction on hearing, speech, language, and voice are examined. Methods for assessing the effects of nasal obstruction are delineated, and recommendations for therapeutic interventions are described.

  11. Lab-on-a-disc agglutination assay for protein detection by optomagnetic readout and optical imaging using nano- and micro-sized magnetic beads.

    PubMed

    Uddin, Rokon; Burger, Robert; Donolato, Marco; Fock, Jeppe; Creagh, Michael; Hansen, Mikkel Fougt; Boisen, Anja

    2016-11-15

    We present a biosensing platform for the detection of proteins based on agglutination of aptamer coated magnetic nano- or microbeads. The assay, from sample to answer, is integrated on an automated, low-cost microfluidic disc platform. This ensures fast and reliable results due to a minimum of manual steps involved. The detection of the target protein was achieved in two ways: (1) optomagnetic readout using magnetic nanobeads (MNBs); (2) optical imaging using magnetic microbeads (MMBs). The optomagnetic readout of agglutination is based on optical measurement of the dynamics of MNB aggregates whereas the imaging method is based on direct visualization and quantification of the average size of MMB aggregates. By enhancing magnetic particle agglutination via application of strong magnetic field pulses, we obtained identical limits of detection of 25pM with the same sample-to-answer time (15min 30s) using the two differently sized beads for the two detection methods. In both cases a sample volume of only 10µl is required. The demonstrated automation, low sample-to-answer time and portability of both detection instruments as well as integration of the assay on a low-cost disc are important steps for the implementation of these as portable tools in an out-of-lab setting. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Molecular characteristics of methicillin-resistant Staphylococcus aureus nasal carriage from hospitalized patients and medical staff in Isfahan, Iran.

    PubMed

    Moshtagheian, S; Halaji, M; Sedaghat, H; Shahin, M; Esfahani, B N; Havaei, S R; Havaei, S A

    2018-01-01

    Nasal carriage of methicillin-resistant Staphylococcus aureus (MRSA) has been accounted as one of the main risk factors for the development of complicated nosocomial infections. The present study aimed to determine nasal carriage rate, antimicrobial susceptibility pattern and molecular characteristics of MRSA isolates. This cross-sectional study was performed within 6 months period from July 2015 at 3 hospitals of Isfahan, Iran. Totally, 326 nasal samples were collected by cotton sterile swab from the nasal cavity of participants. Standard microbiological methods were used for identification S. aurues and MRSA isolates. Antibiotic susceptibility pattern was determined by the disc diffusion method according to the CLSI recommendation. Determination of SCCmec typing, agr groups, and virulence genes were performed by PCR method. Overall, 23.6% of cases were S. aureus carriers including, 23.4% (25/107) of HCWs and 23.7% (52/219) of patients. The rate of MRSA nasal carriages among patients was found to be 51.9% and 16% in HCWs. The highest levels of resistance among MRSA isolates were against ampicillin (93.5%) and tetracycline (83.4%); while, the most effective antibiotics were vancomycin and co-trimoxazole with 100% and 71%, susceptibility. The presence of hla and pvl genes was detected in 80.6% and 3.2% of MRSA isolates, respectively. SCCmec types I, III, IV and V were found in 16.1%, 25.8%, 25.8%, and 16.1% of isolates, respectively. Moreover, agr group I was the predominant type with 43.3. Our results showed a high rate of MRSA colonization in hospitalized patients which remains a significant healthcare problem in our region.

  13. Signatures of broken protoplanetary discs in scattered light and in sub-millimetre observations

    NASA Astrophysics Data System (ADS)

    Facchini, Stefano; Juhász, Attila; Lodato, Giuseppe

    2018-02-01

    Spatially resolved observations of protoplanetary discs are revealing that their inner regions can be warped or broken from the outer disc. A few mechanisms are known to lead to such 3D structures; among them, the interaction with a stellar companion. We perform a 3D SPH simulation of a circumbinary disc misaligned by 60° with respect to the binary orbital plane. The inner disc breaks from the outer regions, precessing as a rigid body and leading to a complex evolution. As the inner disc precesses, the misalignment angle between the inner and outer discs varies by more than 100°. Different snapshots of the evolution are post-processed with a radiative transfer code, in order to produce observational diagnostics of the process. Even though the simulation was produced for the specific case of a circumbinary disc, most of the observational predictions hold for any disc hosting a precessing inner rim. Synthetic scattered light observations show strong azimuthal asymmetries, where the pattern depends strongly on the misalignment angle between the inner and outer discs. The asymmetric illumination of the outer disc leads to azimuthal variations of the temperature structure, in particular in the upper layers, where the cooling time is short. These variations are reflected in asymmetric surface brightness maps of optically thick lines, as CO J = 3-2. The kinematical information obtained from the gas lines is unique in determining the disc structure. The combination of scattered light images and (sub-)mm lines can distinguish between radial inflow and misaligned inner disc scenarios.

  14. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external nasal...

  15. 21 CFR 874.3900 - Nasal dilator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external nasal...

  16. Effects of disc warping on the inclination evolution of star-disc-binary systems

    NASA Astrophysics Data System (ADS)

    Zanazzi, J. J.; Lai, Dong

    2018-07-01

    Several recent studies have suggested that circumstellar discs in young stellar binaries may be driven into misalignement with their host stars due to the secular gravitational interactions between the star, disc, and the binary companion. The disc in such systems is twisted/warped due to the gravitational torques from the oblate central star and the external companion. We calculate the disc warp profile, taking into account the bending wave propagation and viscosity in the disc. We show that for typical protostellar disc parameters, the disc warp is small, thereby justifying the `flat-disc' approximation adopted in previous theoretical studies. However, the viscous dissipation associated with the small disc warp/twist tends to drive the disc towards alignment with the binary or the central star. We calculate the relevant time-scales for the alignment. We find that the alignment is effective for sufficiently cold discs with strong external torques, especially for systems with rapidly rotating stars, but is ineffective for the majority of the star-disc-binary systems. Viscous warp-driven alignment may be necessary to account for the observed spin-orbit alignment in multiplanet systems if these systems are accompanied by an inclined binary companion.

  17. [Nasal septal abscess].

    PubMed

    Barril, María F; Ferolla, Fausto M; José, Pablo; Echave, Cecilia; Tomezzoli, Silvana; Fiorini, Sandra; López, Eduardo Luis

    2008-12-01

    A nasal septal abscess (NA) is defined as a collection of pus between the cartilage or bony septum and its normally applied mucoperichondrium or mucoperiostium. It is an uncommon disease which should be suspected in a patient with acute onset of nasal obstruction and recent history of nasal trauma, periodontal infection or an inflammatory process of the rhinosinusal region. We report a case of an 8-year-old boy with bilateral NA caused by community-acquired methicillin-resistant Staphylococcus aureus(MR-CO) in order to emphasize the importance of prompt diagnosis and adequate treatment to prevent the potentially dangerous spread of infection and the development of severe functional and cosmetic sequelae.

  18. ARGALI: an automatic cup-to-disc ratio measurement system for glaucoma detection and AnaLysIs framework

    NASA Astrophysics Data System (ADS)

    Liu, J.; Wong, D. W. K.; Lim, J. H.; Li, H.; Tan, N. M.; Wong, T. Y.

    2009-02-01

    Glaucoma is an irreversible ocular disease leading to permanent blindness. However, early detection can be effective in slowing or halting the progression of the disease. Physiologically, glaucoma progression is quantified by increased excavation of the optic cup. This progression can be quantified in retinal fundus images via the optic cup to disc ratio (CDR), since in increased glaucomatous neuropathy, the relative size of the optic cup to the optic disc is increased. The ARGALI framework constitutes of various segmentation approaches employing level set, color intensity thresholds and ellipse fitting for the extraction of the optic cup and disc from retinal images as preliminary steps. Following this, different combinations of the obtained results are then utilized to calculate the corresponding CDR values. The individual results are subsequently fused using a neural network. The learning function of the neural network is trained with a set of 100 retinal images For testing, a separate set 40 images is then used to compare the obtained CDR against a clinically graded CDR, and it is shown that the neural network-based result performs better than the individual components, with 96% of the results within intra-observer variability. The results indicate good promise for the further development of ARGALI as a tool for the early detection of glaucoma.

  19. Optical Disks.

    ERIC Educational Resources Information Center

    Gale, John C.; And Others

    1985-01-01

    This four-article section focuses on information storage capacity of the optical disk covering the information workstation (uses microcomputer, optical disk, compact disc to provide reference information, information content, work product support); use of laser videodisc technology for dissemination of agricultural information; encoding databases…

  20. Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis

    PubMed Central

    Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil

    2012-01-01

    Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869

  1. Nasal Glial Heterotopia with Cleft Palate.

    PubMed

    Chandna, Sudhir; Mehta, Milind A; Kulkarni, Abhishek Kishore

    2018-01-01

    Congenital midline nasal masses are rare anomalies of which nasal glial heterotopia represents an even rarer subset. We report a case of a 25-day-old male child with nasal glial heterotopia along with cleft palate suggesting embryonic fusion anomaly which was treated with excision and primary closure for nasal mass followed by palatal repair at later date.

  2. [Hemangiopericytoma in nasal cavity: a case report].

    PubMed

    Hu, Honghai; Shi, Qifeng; Chen, Jidong

    2015-05-01

    We report a case of a 46 year old female patient with nasal hemangiopericytoma. She complained of left nasal congestion, pus snot for 10 years, sometimes with left nasal bleeding. Physical examination: in the left nasal tract saw red soft neoplasm, roughness surface, easy bleeding when touched. Sinus CT shows: bilateral maxillary sinus, ethmoid sinus, sphenoid sinus and the left posterior nasal cavity lesions, considering inflammation with the formation of polyps, tumor not excluded. The left nasal cavity neoplasm biopsy shows: hemangioma of left nasal cavity. After admission in general anesthesia, we do transnasal endoscopic sinus openning operation and the left nasal cavity neoplasm resection. Postoperative pathological examination shows: the left nasal cavity hemangiopericytoma. Immunohistochemical showed: Vimentin(+), Smooth muscle actin(+), Desmin(-), endothelial cells CD31(-) and CD34(-). No postoperative radiotherapy or chemotherapy, no tumor recurrence. After one year of follow-up, the contact was lost.

  3. Objective measurements for grading the nasal esthetics on Basal view in individuals with secondary cleft nasal deformity.

    PubMed

    He, Xing; Li, Hua; Shao, Yan; Shi, Bing

    2015-01-01

    The purpose of this study is to ascertain objective nasal measurements from the basal view that are predictive of nasal esthetics in individuals with secondary cleft nasal deformity. Thirty-three patients who had undergone unilateral cleft lip repair were retrospectively reviewed in this study. The degree of nasal deformity was subjectively ranked by seven surgeons using standardized basal-view measurements. Nine physical objective parameters including angles and ratios were measured. Correlations and regressions between these objective and subjective measurements were then analyzed. There was high concordance in subjective measurements by different surgeons (Kendall's harmonious coefficient = W = .825, P = .006). The strongest predictive factors for nasal aesthetics were the ratio of length of nasal alar (r = .370, P = .034) and the degree of deviation of the columnar axis (r = .451, P = .008). The columellar angle had a more powerful effect in rating nasal esthetics. There was reliable concordance in subjective ranking of nasal esthetics by surgeons. Measurement of the columnar angle may serve as an independent, objective predictor of esthetics of the nose.

  4. Toxocara optic neuropathy: clinical features and ocular findings.

    PubMed

    Choi, Kwang-Dong; Choi, Jae-Hwan; Choi, Seo-Young; Jung, Jae Ho

    2018-01-01

    We evaluated thirteen eyes of twelve patients diagnosed clinically and serologically with Toxocara optic neuropathy. Eleven patients had unilateral involvement and one patient had bilateral optic neuropathy. Eight patients (66.7%) had a possible infection source to Toxocara. Six patients (50%) had painless acute optic neuropathy. Ten eyes had asymmetric, sectorial optic disc edema with peripapillary infiltration and three eyes had diffuse optic disc edema. Eosinophilia was noted in five patients (41.7%) and optic nerve enhancement was observed in eight of eleven eyes (72.7%) with available orbit magnetic resonance imaging (MRI). Mean visual acuity significantly improved following treatment [mean logarithmic of the minimum angle of resolution (logMAR) 0.94±0.56 at baseline and 0.47±0.59 at the final ( P =0.02)]. Asymmetric optic disc edema with a peripapillary lesion and a history of raw meat ingestion were important clues for diagnosing Toxocara optic neuropathy. Additionally, Toxocara IgG enzyme-linked immunosorbent assay (ELISA) test and evaluating eosinophil may be helpful for diagnosis.

  5. Toxocara optic neuropathy: clinical features and ocular findings

    PubMed Central

    Choi, Kwang-Dong; Choi, Jae-Hwan; Choi, Seo-Young; Jung, Jae Ho

    2018-01-01

    We evaluated thirteen eyes of twelve patients diagnosed clinically and serologically with Toxocara optic neuropathy. Eleven patients had unilateral involvement and one patient had bilateral optic neuropathy. Eight patients (66.7%) had a possible infection source to Toxocara. Six patients (50%) had painless acute optic neuropathy. Ten eyes had asymmetric, sectorial optic disc edema with peripapillary infiltration and three eyes had diffuse optic disc edema. Eosinophilia was noted in five patients (41.7%) and optic nerve enhancement was observed in eight of eleven eyes (72.7%) with available orbit magnetic resonance imaging (MRI). Mean visual acuity significantly improved following treatment [mean logarithmic of the minimum angle of resolution (logMAR) 0.94±0.56 at baseline and 0.47±0.59 at the final (P=0.02)]. Asymmetric optic disc edema with a peripapillary lesion and a history of raw meat ingestion were important clues for diagnosing Toxocara optic neuropathy. Additionally, Toxocara IgG enzyme-linked immunosorbent assay (ELISA) test and evaluating eosinophil may be helpful for diagnosis. PMID:29600190

  6. Nasal mucosal gene expression in patients with allergic rhinitis with and without nasal polyps.

    PubMed

    Fritz, Stephen B; Terrell, Jeffrey E; Conner, Edward R; Kukowska-Latallo, Jolanta F; Baker, James R

    2003-12-01

    Nasal polyps are a common problem that is difficult to diagnose and treat, in part because the cause of nasal polyposis is unknown. Although information on the pathogenesis of polyposis is lacking, there are reports suggesting that a genetic predisposition underlies this disorder. We sought to better understand the basis of nasal polyposis associated with allergic rhinitis. We hypothesize that the expression of unique genes is associated with the nasal polyposis phenotype. We examined 12000 human genes transcribed in the nasal mucosa of patients with allergic rhinitis with and without nasal polyps. Biopsy specimens of the mucosa of patients with and without polyps were obtained after the patients refrained from the use of topical or systemic steroid therapy for 2 weeks. Thirty-four genes were differentially expressed between the patient groups, including those for inflammatory molecules and putative growth factors. The greatest differential expression identified by the array analysis was for a group of genes associated with neoplasia, including mammaglobin, a gene transcribed 12-fold higher in patients with polyps compared with control patients with rhinitis alone. Quantitative RT-PCR confirmed this differential expression and documented that the number of mammaglobin mRNA copies is actually 64-fold greater in tissues of patients with polyps versus control patients. The specificity of mammaglobin protein expression was evaluated by means of immunohistochemistry, which showed specific staining in nasal polyp mucosal goblet cells only in patients with polyps. These data suggest that nasal polyposis involves deregulated cell growth, using gene activation in some ways similar to a neoplasm. In addition, mammaglobin, a gene of unknown function associated with breast neoplasia, might be related to polyp growth.

  7. Visualization and Quantification of Nasal and Olfactory Deposition in a Sectional Adult Nasal Airway Cast.

    PubMed

    Xi, Jinxiang; Yuan, Jiayao Eddie; Zhang, Yu; Nevorski, Dannielle; Wang, Zhaoxuan; Zhou, Yue

    2016-06-01

    To compare drug deposition in the nose and olfactory region with different nasal devices and administration techniques. A Sar-Gel based colorimetry method will be developed to quantify local deposition rates. A sectional nasal airway cast was developed based on an MRI-based nasal airway model to visualize deposition patterns and measure regional dosages. Four nasal spray pumps and four nebulizers were tested with both standard and point-release administration techniques. Delivered dosages were measured using a high-precision scale. The colorimetry correlation for deposited mass was developed via image processing in Matlab and its performance was evaluated through comparison to experimental measurements. Results show that the majority of nasal spray droplets deposited in the anterior nose while only a small fraction (less than 4.6%) reached the olfactory region. For all nebulizers considered, more droplets went beyond the nasal valve, leading to distinct deposition patterns as a function of both the nebulizer type (droplet size and initial speed) and inhalation flow rate. With the point-release administration, up to 9.0% (±1.9%) of administered drugs were delivered to the olfactory region and 15.7 (±2.4%) to the upper nose using Pari Sinus. Standard nasal devices are inadequate to deliver clinically significant olfactory dosages without excess drug losses in other nasal epitheliums. The Sar-Gel based colorimetry method appears to provide a simple and practical approach to visualize and quantify regional deposition.

  8. Kozai-Lidov disc instability

    NASA Astrophysics Data System (ADS)

    Lubow, Stephen H.; Ogilvie, Gordon I.

    2017-08-01

    Recent results by Martin et al. showed in 3D smoothed particle hydrodynamics simulations that tilted discs in binary systems can be unstable to the development of global, damped Kozai-Lidov (KL) oscillations in which the discs exchange tilt for eccentricity. We investigate the linear stability of KL modes for tilted inviscid discs under the approximations that the disc eccentricity is small and the disc remains flat. By using 1D equations, we are able to probe regimes of large ratios of outer to inner disc edge radii that are realistic for binary systems of hundreds of astronomical unit separations and are not easily probed by multidimensional simulations. For order unity binary mass ratios, KL instability is possible for a window of disc aspect ratios H/r in the outer parts of a disc that roughly scale as (nb/n)2 ≲ H/r ≲ nb/n, for binary orbital frequency nb and orbital frequency n at the disc outer edge. We present a framework for understanding the zones of instability based on the determination of branches of marginally unstable modes. In general, multiple growing eccentric KL modes can be present in a disc. Coplanar apsidal-nodal precession resonances delineate instability branches. We determine the range of tilt angles for unstable modes as a function of disc aspect ratio. Unlike the KL instability for free particles that involves a critical (minimum) tilt angle, disc instability is possible for any non-zero tilt angle depending on the disc aspect ratio.

  9. Health risks associated with inhaled nasal toxicants.

    PubMed

    Feron, V J; Arts, J H; Kuper, C F; Slootweg, P J; Woutersen, R A

    2001-05-01

    Health risks of inhaled nasal toxicants were reviewed with emphasis on chemically induced nasal lesions in humans, sensory irritation, olfactory and trigeminal nerve toxicity, nasal immunopathology and carcinogenesis, nasal responses to chemical mixtures, in vitro models, and nasal dosimetry- and metabolism-based extrapolation of nasal data in animals to humans. Conspicuous findings in humans are the effects of outdoor air pollution on the nasal mucosa, and tobacco smoking as a risk factor for sinonasal squamous cell carcinoma. Objective methods in humans to discriminate between sensory irritation and olfactory stimulation and between adaptation and habituation have been introduced successfully, providing more relevant information than sensory irritation studies in animals. Against the background of chemoperception as a dominant window of the brain on the outside world, nasal neurotoxicology is rapidly developing, focusing on olfactory and trigeminal nerve toxicity. Better insight in the processes underlying neurogenic inflammation may increase our knowledge of the causes of the various chemical sensitivity syndromes. Nasal immunotoxicology is extremely complex, which is mainly due to the pivotal role of nasal lymphoid tissue in the defense of the middle ear, eye, and oral cavity against antigenic substances, and the important function of the nasal passages in brain drainage in rats. The crucial role of tissue damage and reactive epithelial hyperproliferation in nasal carcinogenesis has become overwhelmingly clear as demonstrated by the recently developed biologically based model for predicting formaldehyde nasal cancer risk in humans. The evidence of carcinogenicity of inhaled complex mixtures in experimental animals is very limited, while there is ample evidence that occupational exposure to mixtures such as wood, leather, or textile dust or chromium- and nickel-containing materials is associated with increased risk of nasal cancer. It is remarkable that these

  10. Nasal packing and stenting

    PubMed Central

    Weber, Rainer K.

    2011-01-01

    Nasal packs are indispensable in ENT practice. This study reviews current indications, effectiveness and risks of nasal packs and stents. In endoscopic surgery, nasal packs should always have smooth surfaces to minimize mucosal damage, improve wound healing and increase patient comfort. Functional endoscopic endonasal sinus surgery allows the use of modern nasal packs, since pressure is no longer required. So called hemostatic/resorbable materials are a first step in this direction. However, they may lead to adhesions and foreign body reactions in mucosal membranes. Simple occlusion is an effective method for creating a moist milieu for improved wound healing and avoiding dryness. Stenting of the frontal sinus is recommended if surgery fails to produce a wide, physiologically shaped drainage path that is sufficiently covered by intact tissue. PMID:22073095

  11. Appraisal of transverse nasal groove: a study.

    PubMed

    Sathyanarayana, Belagola D; Basavaraj, Halevoor B; Nischal, Kuchangi C; Swaroop, Mukunda R; Umashankar, Puttagangu N; Agrawal, Dhruv P; Swamy, Suchetha S; Okram, Sarda

    2012-01-01

    Transverse nasal groove is a condition of cosmetic concern which awaits due recognition and has been widely described as a shallow groove that extends transversely over the dorsum of nose. However, we observed variations in the clinical presentations of this entity, hitherto undescribed in literature. We conducted a clinicoepidemiological study of transverse nasal lesions in patients attending our outpatient department. We conducted a prospective observational study. We screened all patients attending our out-patient department for presence of transverse nasal lesions, signs of any dermatosis and associated other skin conditions. One hundred patients were recruited in the study. Females (80%) predominated over males. Most patients were of 15-45 years age group (70%). Majority of the transverse nasal lesions were classical transverse nasal groove (39%) and others included transverse nasal line (28%), strip (28%), ridge (4%) and loop (1%). Seborrhoeic diathesis was the most common condition associated with transverse nasal lesion. Occurrence of transverse nasal line, strip, ridge and loop, in addition to classical transverse nasal groove implies that latter is actually a subset of transverse nasal lesions. Common association of this entity with seborrheic dermatitis, seborrhea and dandruff raises a possibility of whether transverse nasal lesion is a manifestation of seborrheic diathesis.

  12. The transiting dust clumps in the evolved disc of the Sun-like UXor RZ Psc

    NASA Astrophysics Data System (ADS)

    Kennedy, Grant M.; Kenworthy, Matthew A.; Pepper, Joshua; Rodriguez, Joseph E.; Siverd, Robert J.; Stassun, Keivan G.; Wyatt, Mark C.

    2017-01-01

    RZ Psc is a young Sun-like star, long associated with the UXor class of variable stars, which is partially or wholly dimmed by dust clumps several times each year. The system has a bright and variable infrared excess, which has been interpreted as evidence that the dimming events are the passage of asteroidal fragments in front of the host star. Here, we present a decade of optical photometry of RZ Psc and take a critical look at the asteroid belt interpretation. We show that the distribution of light curve gradients is non-uniform for deep events, which we interpret as possible evidence for an asteroidal fragment-like clump structure. However, the clumps are very likely seen above a high optical depth midplane, so the disc's bulk clumpiness is not revealed. While circumstantial evidence suggests an asteroid belt is more plausible than a gas-rich transition disc, the evolutionary status remains uncertain. We suggest that the rarity of Sun-like stars showing disc-related variability may arise because (i) any accretion streams are transparent and/or (ii) turbulence above the inner rim is normally shadowed by a flared outer disc.

  13. The transiting dust clumps in the evolved disc of the Sun-like UXor RZ Psc.

    PubMed

    Kennedy, Grant M; Kenworthy, Matthew A; Pepper, Joshua; Rodriguez, Joseph E; Siverd, Robert J; Stassun, Keivan G; Wyatt, Mark C

    2017-01-01

    RZ Psc is a young Sun-like star, long associated with the UXor class of variable stars, which is partially or wholly dimmed by dust clumps several times each year. The system has a bright and variable infrared excess, which has been interpreted as evidence that the dimming events are the passage of asteroidal fragments in front of the host star. Here, we present a decade of optical photometry of RZ Psc and take a critical look at the asteroid belt interpretation. We show that the distribution of light curve gradients is non-uniform for deep events, which we interpret as possible evidence for an asteroidal fragment-like clump structure. However, the clumps are very likely seen above a high optical depth midplane, so the disc's bulk clumpiness is not revealed. While circumstantial evidence suggests an asteroid belt is more plausible than a gas-rich transition disc, the evolutionary status remains uncertain. We suggest that the rarity of Sun-like stars showing disc-related variability may arise because (i) any accretion streams are transparent and/or (ii) turbulence above the inner rim is normally shadowed by a flared outer disc.

  14. Application of a relativistic accretion disc model to X-ray spectra of LMC X-1 and GRO J1655-40

    NASA Astrophysics Data System (ADS)

    Gierliński, Marek; Maciołek-Niedźwiecki, Andrzej; Ebisawa, Ken

    2001-08-01

    We present a general relativistic accretion disc model and its application to the soft-state X-ray spectra of black hole binaries. The model assumes a flat, optically thick disc around a rotating Kerr black hole. The disc locally radiates away the dissipated energy as a blackbody. Special and general relativistic effects influencing photons emitted by the disc are taken into account. The emerging spectrum, as seen by a distant observer, is parametrized by the black hole mass and spin, the accretion rate, the disc inclination angle and the inner disc radius. We fit the ASCA soft-state X-ray spectra of LMC X-1 and GRO J1655-40 by this model. We find that, having additional limits on the black hole mass and inclination angle from optical/UV observations, we can constrain the black hole spin from X-ray data. In LMC X-1 the constraint is weak, and we can only rule out the maximally rotating black hole. In GRO J1655-40 we can limit the spin much better, and we find 0.68<=a<=0.88. Accretion discs in both sources are radiation-pressure dominated. We do not find Compton reflection features in the spectra of any of these objects.

  15. Optical coherence tomography angiography in acute arteritic and non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Balducci, Nicole; Morara, Mariachiara; Veronese, Chiara; Barboni, Piero; Casadei, Nicoletta Lelli; Savini, Giacomo; Parisi, Vincenzo; Sadun, Alfredo A; Ciardella, Antonio

    2017-11-01

    The purpose of our study was to describe the feature of acute non-arteritic or arteritic anterior ischemic optic neuropathy (NA-AION and A-AION) using optical coherence tomography angiography (OCT-A) and to compare it with fluorescein angiography (FA) and indocyanine green angiography (ICGA). In this retrospective, observational case-control study four NA-AION patients and one A-AION patient were examined by FA, ICGA and OCT-A within 2 weeks from disease presentation. The characteristics of the images were analyzed. Optic nerve head (ONH) and radial peripapillary capillaries (RPC) vessel densities (VDs) were compared between NA-AION and controls. In two of four NA-AION cases and in the A-AION patient, OCT-A clearly identified the boundary of the ischemic area at the level of the optic nerve head, which was comparable to optic disc filling defects detected by FA. In the other two NA-AION cases, a generalized leakage from the disc was visible with FA, yet OCT-A still demonstrated sectorial peripapillary capillary network reduction. Both ONH and RPC VDs were reduced in NA-AION patients, when compared to controls. OCT-A was able to identify microvascular defects and VD reduction in cases of acute optic disc edema due to NA-AION and A-AION. OCT-A provides additional information in ischemic conditions of the optic nerve head.

  16. Lumbar Disc Degenerative Disease: Disc Degeneration Symptoms and Magnetic Resonance Image Findings

    PubMed Central

    Saleem, Shafaq; Rehmani, Muhammad Asim Khan; Raees, Aisha; Alvi, Arsalan Ahmad; Ashraf, Junaid

    2013-01-01

    Study Design Cross sectional and observational. Purpose To evaluate the different aspects of lumbar disc degenerative disc disease and relate them with magnetic resonance image (MRI) findings and symptoms. Overview of Literature Lumbar disc degenerative disease has now been proven as the most common cause of low back pain throughout the world. It may present as disc herniation, lumbar spinal stenosis, facet joint arthropathy or any combination. Presenting symptoms of lumbar disc degeneration are lower back pain and sciatica which may be aggravated by standing, walking, bending, straining and coughing. Methods This study was conducted from January 2012 to June 2012. Study was conducted on the diagnosed patients of lumbar disc degeneration. Diagnostic criteria were based upon abnormal findings in MRI. Patients with prior back surgery, spine fractures, sacroiliac arthritis, metabolic bone disease, spinal infection, rheumatoid arthritis, active malignancy, and pregnancy were excluded. Results During the targeted months, 163 patients of lumbar disc degeneration with mean age of 43.92±11.76 years, came into Neurosurgery department. Disc degeneration was most commonly present at the level of L4/L5 105 (64.4%).Commonest types of disc degeneration were disc herniation 109 (66.9%) and lumbar spinal stenosis 37 (22.7%). Spondylolisthesis was commonly present at L5/S1 10 (6.1%) and associated mostly with lumbar spinal stenosis 7 (18.9%). Conclusions Results reported the frequent occurrence of lumbar disc degenerative disease in advance age. Research efforts should endeavor to reduce risk factors and improve the quality of life. PMID:24353850

  17. Nasal budesonide offers superior symptom relief in perennial allergic rhinitis in comparison to nasal azelastine.

    PubMed

    Stern, M A; Wade, A G; Ridout, S M; Cambell, L M

    1998-10-01

    Allergic rhinitis is usually treated with oral antihistamines or nasal steroids. Topically active nasal antihistamine is a new treatment modality for allergic rhinitis. The efficacy in comparison to well established topical treatment alternatives is not fully known. To compare the efficacy of intranasally administered azelastine to budesonide, at their respectively recommended dosage, on the symptoms of perennial rhinitis patients. A placebo-controlled, randomized, parallel group study was conducted to compare the efficacy and tolerability of intranasal budesonide aqueous suspension (256 microg once daily) with azelastine hydrochloride nasal spray (280 microg twice daily (560 microg/day)) and with placebo in the treatment of perennial allergic rhinitis. The 195 patients (with at least a 2-year history of perennial allergic rhinitis) recorded individual nasal symptom scores, the degree of symptom control achieved and any adverse events experienced over a 2-week baseline period and a 6-week treatment period. Following treatment, the reductions in mean combined and individual nasal symptom scores from baseline values were significantly greater in the budesonide group compared with the placebo group (P < .0001 for all variables except runny nose P = .01). In patients treated with budesonide, there were also significantly larger reductions from baseline values in combined nasal symptom scores (P < .01) and in scores for all individual nasal symptoms (P < or = .05) compared with those treated with azelastine. The reductions from baseline in both combined and individual nasal symptom scores did not differ between azelastine and placebo. The study medications were well tolerated, producing no unexpected or serious treatment-related adverse events. A once-daily dose of 256 microg of intranasal budesonide aqueous suspension is significantly more effective at relieving the symptoms of perennial allergic rhinitis compared with a twice daily dose of 280 microg of azelastine

  18. The Relation of White-on-White Standard Automated Perimetry, Short Wavelength Perimetry, and Optic Coherence Tomography Parameters in Ocular Hypertension.

    PubMed

    Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan

    2016-12-01

    The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.

  19. The life cycle of starbursting circumnuclear gas discs

    NASA Astrophysics Data System (ADS)

    Schartmann, M.; Mould, J.; Wada, K.; Burkert, A.; Durré, M.; Behrendt, M.; Davies, R. I.; Burtscher, L.

    2018-01-01

    High-resolution observations from the submm to the optical wavelength regime resolve the central few 100 pc region of nearby galaxies in great detail. They reveal a large diversity of features: thick gas and stellar discs, nuclear starbursts, inflows and outflows, central activity, jet interaction, etc. Concentrating on the role circumnuclear discs play in the life cycles of galactic nuclei, we employ 3D adaptive mesh refinement hydrodynamical simulations with the RAMSES code to self-consistently trace the evolution from a quasi-stable gas disc, undergoing gravitational (Toomre) instability, the formation of clumps and stars and the disc's subsequent, partial dispersal via stellar feedback. Our approach builds upon the observational finding that many nearby Seyfert galaxies have undergone intense nuclear starbursts in their recent past and in many nearby sources star formation is concentrated in a handful of clumps on a few 100 pc distant from the galactic centre. We show that such observations can be understood as the result of gravitational instabilities in dense circumnuclear discs. By comparing these simulations to available integral field unit observations of a sample of nearby galactic nuclei, we find consistent gas and stellar masses, kinematics, star formation and outflow properties. Important ingredients in the simulations are the self-consistent treatment of star formation and the dynamical evolution of the stellar distribution as well as the modelling of a delay time distribution for the supernova feedback. The knowledge of the resulting simulated density structure and kinematics on pc scale is vital for understanding inflow and feedback processes towards galactic scales.

  20. Multicenter study of pars plana vitrectomy for optic disc pit maculopathy: MACPIT study.

    PubMed

    Avci, R; Kapran, Z; Ozdek, Ş; Teke, M Y; Oz, O; Guven, D; Yilmaz, S; Kaderli, B; Durukan, A H; Sobaci, G; Unver, Y B; Akduman, L; Kaynak, S; Dogan, I; Inan, U U

    2017-09-01

    PurposeTo evaluate surgical intervention with pars plana vitrectomy (PPV) for correction of optic disc pit maculopathy (ODP-M).Patients and methodsRetrospective chart review from 13 centres of 51 eyes of 50 patients with ODP-M who underwent PPV between 2002-2014. Anatomic and final best-corrected visual acuity (BCVA) outcomes were evaluated for all cases with different adjuvant techniques.ResultsThere were 23 males and 27 females with median age 25.5 (6-68) years. Preoperative median foveal thickness was 694.5 (331-1384) μm and improved to 252.5 (153-1405) μm. Median BCVA improved from 20/200 (20/20000 to 20/40) to 20/40 (20/2000 to 20/20) with 20/40 or better in 31 eyes. Complete retinal reattachment was achieved in 44 eyes (86.3%) at 7.1 (5.9) months. The good surgical outcomes were achieved in different adjuvant groups. Median follow-up was 24 (6 to 120) months.ConclusionsThese results confirm the long-term effectiveness of PPV for ODP-M. Prospective studies are needed to determine the effectiveness of any adjuvant technique in improving the success of PPV for ODP-M.

  1. Star-disc interaction in galactic nuclei: formation of a central stellar disc

    NASA Astrophysics Data System (ADS)

    Panamarev, Taras; Shukirgaliyev, Bekdaulet; Meiron, Yohai; Berczik, Peter; Just, Andreas; Spurzem, Rainer; Omarov, Chingis; Vilkoviskij, Emmanuil

    2018-05-01

    We perform high-resolution direct N-body simulations to study the effect of an accretion disc on stellar dynamics in an active galactic nucleus (AGN). We show that the interaction of the nuclear stellar cluster (NSC) with the gaseous accretion disc (AD) leads to formation of a stellar disc in the central part of the NSC. The accretion of stars from the stellar disc on to the super-massive black hole is balanced by the capture of stars from the NSC into the stellar disc, yielding a stationary density profile. We derive the migration time through the AD to be 3 per cent of the half-mass relaxation time of the NSC. The mass and size of the stellar disc are 0.7 per cent of the mass and 5 per cent of the influence radius of the super-massive black hole. An AD lifetime shorter than the migration time would result in a less massive nuclear stellar disc. The detection of such a stellar disc could point to past activity of the hosting galactic nucleus.

  2. Nasal symptoms following endoscopic transsphenoidal pituitary surgery: assessment using the General Nasal Patient Inventory.

    PubMed

    Wang, Yi Yuen; Srirathan, Vinothan; Tirr, Erica; Kearney, Tara; Gnanalingham, Kanna K

    2011-04-01

    The endoscopic approach for pituitary tumors is a recent innovation and is said to reduce the nasal trauma associated with transnasal transsphenoidal surgery. The authors assessed the temporal changes in the rhinological symptoms following endoscopic transsphenoidal surgery for pituitary lesions, using the General Nasal Patient Inventory (GNPI). The GNPI was administered to 88 consecutive patients undergoing endoscopic transsphenoidal surgery at 3 time points (presurgery, 3-6 months postsurgery, and at final follow-up). The total GNPI score and the scores for the individual GNPI questions were calculated and differences between groups were assessed once before surgery, several months after surgery, and at final follow-up. Of a maximum possible score of 135, the mean GNPI score at 3-6 months postsurgery was only 12.9 ± 12 and was not significantly different from the preoperative score (10.4 ± 13) or final follow-up score (10.3 ± 10). Patients with functioning tumors had higher GNPI scores than those with nonfunctioning tumors for each of these time points (p < 0.05). Individually, a mild increase in symptom severity was seen for symptoms attributable to the nasal trauma of surgery, with partial recovery (nasal sores and bleeding) or complete recovery (nasal blockage, painful sinuses, and unpleasant nasal smell) by final follow-up (p < 0.05). Progressive improvements in symptom severity were seen for symptoms more attributable to tumor mass preoperatively (for example, headaches and painkiller use [p < 0.05]). In total, by final follow-up 8 patients (9%) required further treatment or advice for ongoing nasal symptoms. Endoscopic transsphenoidal surgery is a well-tolerated minimally invasive procedure for pituitary fossa lesions. Overall patient-assessed nasal symptoms do not change, but some individual symptoms may show a mild worsening or overall improvement.

  3. Transient events in bright debris discs: Collisional avalanches revisited

    NASA Astrophysics Data System (ADS)

    Thebault, P.; Kral, Q.

    2018-01-01

    Context. A collisional avalanche is set off by the breakup of a large planetesimal, releasing vast amounts of small unbound grains that enter a debris disc located further away from the star, triggering there a collisional chain reaction that could potentially create detectable transient structures. Aims: We investigate this mechanism, using for the first time a fully self-consistent code coupling dynamical and collisional evolutions. We also quantify for the first time the photometric evolution of the system and investigate whether or not avalanches could explain the short-term luminosity variations recently observed in some extremely bright debris discs. Methods: We use the state-of-the-art LIDT-DD code. We consider an avalanche-favoring A6V star, and two set-ups: a "cold disc" case, with a dust release at 10 au and an outer disc extending from 50 to 120 au, and a "warm disc" case with the release at 1 au and a 5-12 au outer disc. We explore, in addition, two key parameters: the density (parameterized by its optical depth τ) of the main outer disc and the amount of dust released by the initial breakup. Results: We find that avalanches could leave detectable structures on resolved images, for both "cold" and "warm" disc cases, in discs with τ of a few 10-3, provided that large dust masses (≳1020-5 × 1022 g) are initially released. The integrated photometric excess due to an avalanche is relatively limited, less than 10% for these released dust masses, peaking in the λ 10-20 μm domain and becoming insignificant beyond 40-50 μm. Contrary to earlier studies, we do not obtain stronger avalanches when increasing τ to higher values. Likewise, we do not observe a significant luminosity deficit, as compared to the pre-avalanche level, after the passage of the avalanche. These two results concur to make avalanches an unlikely explanation for the sharp luminosity drops observed in some extremely bright debris discs. The ideal configuration for observing an

  4. Outer edges of debris discs. How sharp is sharp?

    NASA Astrophysics Data System (ADS)

    Thébault, P.; Wu, Y.

    2008-04-01

    Context: Rings or annulus-like features have been observed in most imaged debris discs. Outside the main ring, while some systems (e.g., β Pictoris and AU Mic) exhibit smooth surface brightness profiles (SB) that fall off roughly as ~r-3.5, others (e.g. HR 4796A and HD 139664) display large drops in luminosity at the ring's outer edge and steeper radial luminosity profiles. Aims: We seek to understand this diversity of outer edge profiles under the “natural” collisional evolution of the system, without invoking external agents such as planets or gas. Methods: We use a multi-annulus statistical code to follow the evolution of a collisional population, ranging in size from dust grains to planetesimals and initially confined within a belt (the “birth ring”). The crucial effect of radiation pressure on the dynamics and spatial distribution of the smallest grains is taken into account. We explore the dependence of the resulting disc surface brightness profile on various parameters. Results: The disc typically evolves toward a “standard” steady state, where the radial surface brightness profile smoothly decreases with radius as r-3.5 outside the birth ring. This confirms and extends the semi-analytical study of Strubbe & Chiang (2006, ApJ, 648, 652) and provides a firm basis for interpreting observed discs. Deviations from this typical profile, in the form of a sharp outer edge and a steeper fall-off, occur for two “extreme” cases: 1) when the birth ring is so massive that it becomes radially optically thick for the smallest grains. However, the required disc mass is probably too high here to be realistic; 2) when the dynamical excitation of the dust-producing planetesimals is so low (< e> and < i> ≤ 0.01) that the smallest grains, which otherwise dominate the optical depth of the system, are preferentially depleted. This low-excitation case, although possibly not generic, cannot be ruled out by observations for most systems, . Conclusions: Our

  5. Laser-induced activation of regeneration processes in spine disc cartilage

    NASA Astrophysics Data System (ADS)

    Sobol, Emil N.; Vorobjeva, Natalia N.; Sviridov, Alexander P.; Omelchenko, Alexander I.; Baskov, Andrey V.; Shekhter, Anatoliy B.; Baskov, Vladimir A.; Feldchtein, Felix I.; Kamensky, Vladislav A.; Kuranov, Roman V.

    2000-05-01

    The effect of laser radiation on the regeneration processes in spine disk cartilage has been studied in-vivo. We used rabbits as a model and a Holmium (2.09 micrometer) and an Erbium fiber (1.56 micrometer) lasers for irradiation the discs which were preliminary opened to remove annulus fibrosus and the nucleus pulposus of the intervertebral disc. The irradiated zone has been examined using an optical coherent tomography in one month after the operation and conventional histological technique in two months after the laser operation. It has been shown that laser radiation promotes the growth of the new cartilaginous tissue of fibrous and hyaline types.

  6. Adjuncts to Improve Nasal Reconstruction Results.

    PubMed

    Gordon, Shayna Lee; Hurst, Eva A

    2017-02-01

    The final cosmetic appearance of nasal reconstruction scars is of paramount importance to both the patient and surgeon. Ideal postreconstruction nasal scars are flat and indistinguishable from surrounding skin. Unfortunately, even with meticulous surgical execution, nasal scars can occasionally be suboptimal. Abnormal fibroblast response can lead to hypertrophic nasal scars, and excessive angiogenesis may lead to telangiectasias or an erythematous scar. Imperfect surgical closure or poor postoperative management can lead to surgical outcomes with step-offs, depressions, suture marks, or dyspigmentation. Aesthetically unacceptable nasal scars can cause pruritus, tenderness, pain, sleep disturbance, and anxiety and depression in postsurgical patients. Fortunately, there are several minimally invasive or noninvasive techniques that allow for enhancement and improvement of cosmetic results with minimal risk and associated downtime. This article provides an overview of adjuncts to improve nasal reconstruction with a focus on techniques to be used in the postoperative period. Armed with an understanding of relevant available therapies, skillful surgeons may drastically improve the final cosmesis and outcome of nasal reconstruction scars. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Presurgical Nasal Molding With a Nasal Spring in Patients With Mild-to-Moderate Nasal Deformity With Incomplete Unilateral Cleft Lip With or Without Cleft Palate.

    PubMed

    Peanchitlertkajorn, Supakit

    2018-01-01

    Traditional nasoalveolar molding (NAM) requires steep learning curve for clinicians and significant compliance from parents. Nasal springs have been developed by the author to simplify presurgical nasal molding. This article presents the design, construction, and application of the spring. The treatment goal is to improve nasal deformity prior to primary repair in infants born with incomplete unilateral cleft lip with or without cleft palate. The design, fabrication, and utility of the nasal spring are described. The spring has a simpler design and construction compared to a traditional NAM appliance. Two patients with incomplete unilateral cleft lip with and without cleft palate are presented. The spring is constructed and delivered. The active arm of the spring can be 3-dimensionally (3-D) adjusted to mold the alar cartilage of the affected nostril. The spring does not require an oral plate for adherence as a traditional NAM appliance does, hence an oral impression is not needed. The spring is easy for clinicians to adjust. It also requires less compliance by parents. Main Outcome Measures/Results: The presurgical molding achieved by the use of a nasal spring improved surgical nasolabial aesthetic outcomes. The nasal springs are effective in reducing the initial cleft nasal deformity. This facilitates primary surgical cleft lip and nose correction and improves surgical outcomes in patients with incomplete unilateral cleft lip with or without cleft palate.

  8. Management of Intractable Nasal Hyperreactivity by Selective Resection of Posterior Nasal Nerve Branches

    PubMed Central

    Takahara, Daisuke; Hamamoto, Takao; Ishino, Takashi; Hirakawa, Katsuhiro

    2017-01-01

    The posterior nasal nerves emerge from the sphenopalatine foramen and contain sensory and autonomic nerve components. Posterior nasal neurectomy is an effective method to remove pathological neural networks surrounding the inferior turbinate that cause unregulated nasal hypersensitivity with excess secretion in patients with severe allergic rhinitis (AR). We describe the sophisticated endoscopic surgical procedure that allows feasible access to the confined area and selective resection of the nerve branches with the preservation of the sphenopalatine artery (SPA). We retrospectively analyzed the cases of 23 symptomatic severe AR patients who failed to respond to standard medical treatment and underwent surgery. There have been no major complications after surgery including nasal bleeding or transient numbness of the upper teeth. The mean total nasal symptom scores (TNSS) were decreased by 70.2% at 12 months after the procedure. Our comparison of the clinical effectiveness based on the number of severed nerve branches revealed that the improvement of the TNSS was significantly higher in patients with >2 branches. We conclude that this minimally invasive technique that preserves the SPA is clinically useful and decreases the rate of postoperative complications. This trial is registered with UMIN000029025. PMID:29379524

  9. Management of Intractable Nasal Hyperreactivity by Selective Resection of Posterior Nasal Nerve Branches.

    PubMed

    Takahara, Daisuke; Takeno, Sachio; Hamamoto, Takao; Ishino, Takashi; Hirakawa, Katsuhiro

    2017-01-01

    The posterior nasal nerves emerge from the sphenopalatine foramen and contain sensory and autonomic nerve components. Posterior nasal neurectomy is an effective method to remove pathological neural networks surrounding the inferior turbinate that cause unregulated nasal hypersensitivity with excess secretion in patients with severe allergic rhinitis (AR). We describe the sophisticated endoscopic surgical procedure that allows feasible access to the confined area and selective resection of the nerve branches with the preservation of the sphenopalatine artery (SPA). We retrospectively analyzed the cases of 23 symptomatic severe AR patients who failed to respond to standard medical treatment and underwent surgery. There have been no major complications after surgery including nasal bleeding or transient numbness of the upper teeth. The mean total nasal symptom scores (TNSS) were decreased by 70.2% at 12 months after the procedure. Our comparison of the clinical effectiveness based on the number of severed nerve branches revealed that the improvement of the TNSS was significantly higher in patients with >2 branches. We conclude that this minimally invasive technique that preserves the SPA is clinically useful and decreases the rate of postoperative complications. This trial is registered with UMIN000029025.

  10. A disc inside the bipolar planetary nebula M2-9

    NASA Astrophysics Data System (ADS)

    Lykou, F.; Chesneau, O.; Zijlstra, A. A.; Castro-Carrizo, A.; Lagadec, E.; Balick, B.; Smith, N.

    2011-03-01

    Aims: Bipolarity in proto-planetary and planetary nebulae is associated with events occurring in or around their cores. Past infrared observations have revealed the presence of dusty structures around the cores, many in the form of discs. Characterising those dusty discs provides invaluable constraints on the physical processes that govern the final mass expulsion of intermediate mass stars. We focus this study on the famous M2-9 bipolar nebula, where the moving lighthouse beam pattern indicates the presence of a wide binary. The compact and dense dusty core in the centre of the nebula can be studied by means of optical interferometry. Methods: M2-9 was observed with VLTI/MIDI at 39-47 m baselines with the UT2-UT3 and UT3-UT4 baseline configurations. These observations are interpreted using a dust radiative transfer Monte Carlo code. Results: A disc-like structure is detected perpendicular to the lobes, and a good fit is found with a stratified disc model composed of amorphous silicates. The disc is compact, 25 × 35 mas at 8 μm and 37 × 46 mas at 13 μm. For the adopted distance of 1.2 kpc, the inner rim of the disc is ~15 AU. The mass represents a few percent of the mass found in the lobes. The compactness of the disc puts strong constraints on the binary content of the system, given an estimated orbital period 90-120 yr. We derive masses of the binary components between 0.6-1.0 M⊙ for a white dwarf and 0.6-1.4 M⊙ for an evolved star. We present different scenarios on the geometric structure of the disc accounting for the interactions of the binary system, which includes an accretion disc as well. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere, Chile, ESO N: 079.D-146.

  11. [Disturbances of nasal aerodynamics in patients with the curved nasal septum and the rationale for its surgical correction].

    PubMed

    Tulebaev, R K; Mustafin, A A; Zholdybaeva, Z T

    2011-01-01

    Serious disturbances of nasal aerodynamics contribute to the development of diseases of the broncho-pulmonary apparatus. The early recognition of ventilation problems in patients with the curved nasal septum is paramount for the efficacious prevention and treatment of respiratory complications. The authors describe principles of rhinosurgical correction of affected nasal aerodynamics in patients with the curved nasal septum.

  12. Modeling and optimization of an elastic arthroplastic disc for a degenerated disc

    NASA Astrophysics Data System (ADS)

    Ghouchani, Azadeh; Ravari, Mohammad; Mahmoudi, Farid

    2011-10-01

    A three-dimensional finite element model (FEM) of the L3-L4 motion segment using ABAQUS v 6.9 has been developed. The model took into account the material nonlinearities and is imposed different loading conditions. In this study, we validated the model by comparison of its predictions with several sets of experimental data. Disc deformation under compression and segmental rotational motions under moment loads for the normal disc model agreed well with the corresponding in vivo studies. By linking ABAQUS with MATLAB 2010.a, we determined the optimal Young s modulus as well as the Poisson's ratio for the artificial disc under different physiologic loading conditions. The results of the present study confirmed that a well-designed elastic arthroplastic disc preferably has an annulus modulus of 19.1 MPa and 1.24 MPa for nucleus section and Poisson ratio of 0.41 and 0.47 respectively. Elastic artificial disc with such properties can then achieve the goal of restoring the disc height and mechanical function of intact disc under different loading conditions and so can reduce low back pain which is mostly caused due to disc degeneration.

  13. A Nasal Epithelial Receptor for Staphylococcus aureus WTA Governs Adhesion to Epithelial Cells and Modulates Nasal Colonization

    PubMed Central

    Faulstich, Manuela; Grau, Timo; Severin, Yannik; Unger, Clemens; Hoffmann, Wolfgang H.; Rudel, Thomas; Autenrieth, Ingo B.; Weidenmaier, Christopher

    2014-01-01

    Nasal colonization is a major risk factor for S. aureus infections. The mechanisms responsible for colonization are still not well understood and involve several factors on the host and the bacterial side. One key factor is the cell wall teichoic acid (WTA) of S. aureus, which governs direct interactions with nasal epithelial surfaces. We report here the first receptor for the cell wall glycopolymer WTA on nasal epithelial cells. In several assay systems this type F-scavenger receptor, termed SREC-I, bound WTA in a charge dependent manner and mediated adhesion to nasal epithelial cells in vitro. The impact of WTA and SREC-I interaction on epithelial adhesion was especially pronounced under shear stress, which resembles the conditions found in the nasal cavity. Most importantly, we demonstrate here a key role of the WTA-receptor interaction in a cotton rat model of nasal colonization. When we inhibited WTA mediated adhesion with a SREC-I antibody, nasal colonization in the animal model was strongly reduced at the early onset of colonization. More importantly, colonization stayed low over an extended period of 6 days. Therefore we propose targeting of this glycopolymer-receptor interaction as a novel strategy to prevent or control S. aureus nasal colonization. PMID:24788600

  14. IRAS 22150+6109 - a young B-type star with a large disc

    NASA Astrophysics Data System (ADS)

    Zakhozhay, Olga V.; Miroshnichenko, Anatoly S.; Kuratov, Kenesken S.; Zakhozhay, Vladimir A.; Khokhlov, Serik A.; Zharikov, Sergey V.; Manset, Nadine

    2018-06-01

    We present the results of a spectroscopic analysis and spectral energy distribution (SED) modelling of the optical counterpart of the infrared source IRAS 22150+6109. The source was suggested to be a Herbig Be star located in the star-forming region L 1188. Absorption lines in the optical spectrum indicate a spectral type B3, while weak Balmer emission lines reflect the presence of a circumstellar gaseous disc. The star shows no excess radiation in the near-infrared spectral region and a strong excess in the far-infrared that we interpret as radiation from a large disc, the inner edge of which is located very far from the star (550 au) and does not attenuate its radiation. We conclude that IRAS 22150+6109 is an intermediate-mass star that is currently undergoing a short pre-main-sequence evolutionary stage.

  15. Instability of warped discs

    NASA Astrophysics Data System (ADS)

    Doǧan, S.; Nixon, C. J.; King, A. R.; Pringle, J. E.

    2018-05-01

    Accretion discs are generally warped. If a warp in a disc is too large, the disc can `break' apart into two or more distinct planes, with only tenuous connections between them. Further, if an initially planar disc is subject to a strong differential precession, then it can be torn apart into discrete annuli that precess effectively independently. In previous investigations, torque-balance formulae have been used to predict where and when the disc breaks into distinct parts. In this work, focusing on discs with Keplerian rotation and where the shearing motions driving the radial communication of the warp are damped locally by turbulence (the `diffusive' regime), we investigate the stability of warped discs to determine the precise criterion for an isolated warped disc to break. We find and solve the dispersion relation, which, in general, yields three roots. We provide a comprehensive analysis of this viscous-warp instability and the emergent growth rates and their dependence on disc parameters. The physics of the instability can be understood as a combination of (1) a term that would generally encapsulate the classical Lightman-Eardley instability in planar discs (given by ∂(νΣ)/∂Σ < 0) but is here modified by the warp to include ∂(ν1|ψ|)/∂|ψ| < 0, and (2) a similar condition acting on the diffusion of the warp amplitude given in simplified form by ∂(ν2|ψ|)/∂|ψ| < 0. We discuss our findings in the context of discs with an imposed precession, and comment on the implications for different astrophysical systems.

  16. Thermodynamics of giant planet formation: shocking hot surfaces on circumplanetary discs

    NASA Astrophysics Data System (ADS)

    Szulágyi, J.; Mordasini, C.

    2017-02-01

    The luminosity of young giant planets can inform about their formation and accretion history. The directly imaged planets detected so far are consistent with the `hot-start' scenario of high entropy and luminosity. If nebular gas passes through a shock front before being accreted into a protoplanet, the entropy can be substantially altered. To investigate this, we present high-resolution, three-dimensional radiative hydrodynamic simulations of accreting giant planets. The accreted gas is found to fall with supersonic speed in the gap from the circumstellar disc's upper layers on to the surface of the circumplanetary disc and polar region of the protoplanet. There it shocks, creating an extended hot supercritical shock surface. This shock front is optically thick; therefore, it can conceal the planet's intrinsic luminosity beneath. The gas in the vertical influx has high entropy which when passing through the shock front decreases significantly while the gas becomes part of the disc and protoplanet. This shows that circumplanetary discs play a key role in regulating a planet's thermodynamic state. Our simulations furthermore indicate that around the shock surface extended regions of atomic - sometimes ionized - hydrogen develop. Therefore, circumplanetary disc shock surfaces could influence significantly the observational appearance of forming gas giants.

  17. Patterns of lumbar disc degeneration are different in degenerative disc disease and disc prolapse magnetic resonance imaging analysis of 224 patients.

    PubMed

    Kanna, Rishi M; Shetty, Ajoy Prasad; Rajasekaran, S

    2014-02-01

    Existing research on lumbar disc degeneration has remained inconclusive regarding its etiology, pathogenesis, symptomatology, prevention, and management. Degenerative disc disease (DDD) and disc prolapse (DP) are common diseases affecting the lumbar discs. Although they manifest clinically differently, existing studies on disc degeneration have included patients with both these features, leading to wide variations in observations. The possible relationship or disaffect between DDD and DP is not fully evaluated. To analyze the patterns of lumbar disc degeneration in patients with chronic back pain and DDD and those with acute DP. Prospective, magnetic resonance imaging-based radiological study. Two groups of patients (aged 20-50 years) were prospectively studied. Group 1 included patients requiring a single level microdiscectomy for acute DP. Group 2 included patients with chronic low back pain and DDD. Discs were assessed by magnetic resonance imaging through Pfirmann grading, Schmorl nodes, Modic changes, and the total end-plate damage score for all the five lumbar discs. Group 1 (DP) had 91 patients and group 2 (DDD) had 133 patients. DP and DDD patients differed significantly in the number, extent, and severity of degeneration. DDD patients had a significantly higher number of degenerated discs than DP patients (p<.000). The incidence of multilevel and pan-lumbar degeneration was also significantly higher in DDD group. The pattern of degeneration also differed in both the groups. DDD patients had predominant upper lumbar involvement, whereas DP patients had mainly lower lumbar degeneration. Modic changes were more common in DP patients, especially at the prolapsed level. Modic changes were present in 37% of prolapsed levels compared with 9.9% of normal discs (p<.00). The total end-plate damage score had a positive correlation with disc degeneration in both the groups. Further the mean total end-plate damage score at prolapsed level was also significantly higher

  18. Oxymetazoline plus dexpanthenol in nasal congestion.

    PubMed

    Jagade, Mohan V; Langade, Deepak G; Pophale, Rupesh R; Prabhu, Arun

    2008-12-01

    To compare the efficacy and tolerability of Oxymetazoline 0.05 % plus Dexpanthanol 5% versus Xylometazoline 0.1 % nasal drops in patients with nasal congestion due to allergic rhinitis and following nasal surgery. An investigator-blind, randomized, controlled, phase IV clinical trial conducted in 100 patients with acute allergic rhinitis or patients post-nasal surgery. Patients received either Oxymetazoline 0.05% with Dexpanthanol 5% (OD) or Xylometazoline 0.1% (XO) nasal drops. Relief from nasal congestion was significantly better in the OD group then in the XO group (mean nasal scores 1.24 vs 1.86). Significantly more improvement in sneezing and decrease in nasal discharge was seen in the OD group than the XO group. Nasal irritation in the OD group was significantly less as compared to XO group (0.38 v/s 1.12 on second day and 0.10 vs 0.36 on the fourth day). The recovery time for OD group was 1.08 hours, which was significantly (46 min) lesser than that of the XO group. Rebound congestion was significantly less in OD as compared to XO group (6.25% vs 82.98%). 93.75% of the physicians in the OD group and 51.28% in XO group reported response to therapy as good to excellent. 95.83% patients in the OD group and only 52.91% patients in the XO group rated tolerability to therapy as good to excellent. Oxymetazoline and dexpanthenol combination has a better efficacy, shorter recovery time, causes lesser rebound congestion and has better tolerability than xylometazoline.

  19. Protoplanetary disc `isochrones' and the evolution of discs in the M˙-Md plane

    NASA Astrophysics Data System (ADS)

    Lodato, Giuseppe; Scardoni, Chiara E.; Manara, Carlo F.; Testi, Leonardo

    2017-12-01

    In this paper, we compare simple viscous diffusion models for the disc evolution with the results of recent surveys of the properties of young protoplanetary discs. We introduce the useful concept of 'disc isochrones' in the accretion rate-disc mass plane and explore a set of Monte Carlo realization of disc initial conditions. We find that such simple viscous models can provide a remarkable agreement with the available data in the Lupus star forming region, with the key requirement that the average viscous evolutionary time-scale of the discs is comparable to the cluster age. Our models produce naturally a correlation between mass accretion rate and disc mass that is shallower than linear, contrary to previous results and in agreement with observations. We also predict that a linear correlation, with a tighter scatter, should be found for more evolved disc populations. Finally, we find that such viscous models can reproduce the observations in the Lupus region only in the assumption that the efficiency of angular momentum transport is a growing function of radius, thus putting interesting constraints on the nature of the microscopic processes that lead to disc accretion.

  20. Counter-rotating accretion discs

    NASA Astrophysics Data System (ADS)

    Dyda, S.; Lovelace, R. V. E.; Ustyugova, G. V.; Romanova, M. M.; Koldoba, A. V.

    2015-01-01

    Counter-rotating discs can arise from the accretion of a counter-rotating gas cloud on to the surface of an existing corotating disc or from the counter-rotating gas moving radially inwards to the outer edge of an existing disc. At the interface, the two components mix to produce gas or plasma with zero net angular momentum which tends to free-fall towards the disc centre. We discuss high-resolution axisymmetric hydrodynamic simulations of viscous counter-rotating discs for the cases where the two components are vertically separated and radially separated. The viscosity is described by an isotropic α-viscosity including all terms in the viscous stress tensor. For the vertically separated components, a shear layer forms between them and the middle part of this layer free-falls to the disc centre. The accretion rates are increased by factors of ˜102-104 over that for a conventional disc rotating in one direction with the same viscosity. The vertical width of the shear layer and the accretion rate are strongly dependent on the viscosity and the mass fraction of the counter-rotating gas. In the case of radially separated components where the inner disc corotates and the outer disc rotates in the opposite direction, a gap between the two components opens and closes quasi-periodically. The accretion rates are ≳25 times larger than those for a disc rotating in one direction with the same viscosity.

  1. Nasal dermoid sinus cyst.

    PubMed

    Cauchois, R; Laccourreye, O; Bremond, D; Testud, R; Küffer, R; Monteil, J P

    1994-08-01

    Nasal dermoid sinus cyst is one of the diagnoses of midline nasal masses in children. This retrospective study analyzes the various theories regarding the origin of this congenital abnormality, the differential diagnosis, and the value of magnetic resonance imaging, as well as the various surgical options available.

  2. Fabrication of read-only type triple-layered disc

    NASA Astrophysics Data System (ADS)

    Yang, Huei Wen; Jeng, Tzuan Ren; Yen, Wen Hsin; Chan, Rong Po; Shin, Kuo Ding; Huang, Der Ray

    2003-06-01

    The approach to increase optical recording density has become very popular research subject in these years. One direct and effective method is to increase the recording layer stack number. That is to say, to add one more recording layer can get one more recording capacity. In this paper, we will propose a new method for manufacturing read only type multi-layered disc. The process is described in the following. This first recorded data layer (called L0) still follows the traditional DVD disc manufacturing process. We obtain the polycarbonate substrate by replicating from Ni stamper. Then polycarbonate substrate is sputtered thin silicon film for semi-reflection layer. As for second layer (L1) and even more layer (Ln-1) producing, one special kind of duplication (called SKD) method is proposed. The duplication (or replication) source of second or nth recorded data is not only limited from Ni stamper. Even polycarbonate or PMMA substrate has recording data are also acceptable sources. At next step, the duplication source is deposited by thin gold film. Then we apply spin coating to bond the first layer (L0) substrate and second layer (L1) duplication source by choosing suitable UV curing glue. After being emitted by UV lamp for several seconds, we can easily separate the duplication source of second layer (L1) from (L0) substrate. Then we find the thin second data layer (L1) is replicated and stacks upon the first layer. On the same way, we sputter thin AgTi layer on the thin second data layer for another semi- reflective layer. By following the above manufacture step, we can produce more layers. In our experimental, we prepare triple layered read-only type disc. The total capacity is almost 12GB for one side of disc, and 24GB for two side of disc. The read-out intensity of laser from each data layer is expected to be similar. Thus we have designed particular reflectance and transmittance for each data layer by controlling the thickness of thin silicon film. We can

  3. Evolution of protoplanetary discs with magnetically driven disc winds

    NASA Astrophysics Data System (ADS)

    Suzuki, Takeru K.; Ogihara, Masahiro; Morbidelli, Alessandro; Crida, Aurélien; Guillot, Tristan

    2016-12-01

    Aims: We investigate the evolution of protoplanetary discs (PPDs) with magnetically driven disc winds and viscous heating. Methods: We considered an initially massive disc with 0.1 M⊙ to track the evolution from the early stage of PPDs. We solved the time evolution of surface density and temperature by taking into account viscous heating and the loss of mass and angular momentum by the disc winds within the framework of a standard α model for accretion discs. Our model parameters, turbulent viscosity, disc wind mass-loss, and disc wind torque, which were adopted from local magnetohydrodynamical simulations and constrained by the global energetics of the gravitational accretion, largely depends on the physical condition of PPDs, particularly on the evolution of the vertical magnetic flux in weakly ionized PPDs. Results: Although there are still uncertainties concerning the evolution of the vertical magnetic flux that remains, the surface densities show a large variety, depending on the combination of these three parameters, some of which are very different from the surface density expected from the standard accretion. When a PPD is in a wind-driven accretion state with the preserved vertical magnetic field, the radial dependence of the surface density can be positive in the inner region <1-10 au. The mass accretion rates are consistent with observations, even in the very low level of magnetohydrodynamical turbulence. Such a positive radial slope of the surface density strongly affects planet formation because it inhibits the inward drift or even causes the outward drift of pebble- to boulder-sized solid bodies, and it also slows down or even reversed the inward type-I migration of protoplanets. Conclusions: The variety of our calculated PPDs should yield a wide variety of exoplanet systems.

  4. Speech rate reduction and "nasality" in normal speakers.

    PubMed

    Brancewicz, T M; Reich, A R

    1989-12-01

    This study explored the effects of reduced speech rate on nasal/voice accelerometric measures and nasality ratings. Nasal/voice accelerometric measures were obtained from normal adults for various speech stimuli and speaking rates. Stimuli included three sentences (one obstruent-loaded, one semivowel-loaded, and one containing a single nasal), and /pv/ syllable trains.. Speakers read the stimuli at their normal rate, half their normal rate, and as slowly as possible. In addition, a computer program paced each speaker at rates of 1, 2, and 3 syllables per second. The nasal/voice accelerometric values revealed significant stimulus effects but no rate effects. The nasality ratings of experienced listeners, evaluated as a function of stimulus and speaking rate, were compared to the accelerometric measures. The nasality scale values demonstrated small, but statistically significant, stimulus and rate effects. However, the nasality percepts were poorly correlated with the nasal/voice accelerometric measures.

  5. Topographical analysis of corneal astigmatism in patients with tilted-disc syndrome.

    PubMed

    Bozkurt, Banu; Irkec, Murat; Gedik, Sansal; Orhan, Mehmet; Erdener, Uğur

    2002-07-01

    To evaluate the corneal topography in patients with tilted-disc syndrome to determine the relationship between optic disc dysversion and corneal astigmatism and the pattern of astigmatism in these patients. The study included 23 eyes of the 13 tilted-disc syndrome patients with spheric refractive errors ranging between +1.00 D and -9.00 D (mean -4.00 +/- 3.4 D) and astigmatic errors ranging between -0.50 and -4.50 D (mean -1.95 +/- 0.93 D). Corneal topography was performed by computer-assisted videokeratoscope topographic modelling system 2 (TMS-2) and incidence of corneal astigmatism, corneal topographic patterns, and mean values of the topographic indices were determined. Corneal topographic analysis showed corneal astigmatism in 22 out of 23 patients with tilted discs. Corneal astigmatism was symmetric bow tie pattern in 10 eyes (45.45%), asymmetric bow tie pattern in 11 eyes (50%) and irregular in 1 eye (4.5%). Among the patients with bow tie pattern group (21 eyes), 14 eyes had with-the-rule astigmatism, 1 eye had against-the-rule astigmatism, and 6 eyes had oblique astigmatism. In 18 eyes, astigmatism was corneal, whereas combined corneal and lenticular in 4 eyes and lenticular in 1 eye. In the majority of tilted-disc cases, ocular astigmatism is mainly corneal. Morphogenetic factors in the development of the tilted disc might possibly influence the corneal development in such a way to result in corneal astigmatism.

  6. The activity of N-acetyl-β-d-hexosaminidase A and B and β-glucuronidase in nasal polyps and hypertrophic nasal concha.

    PubMed

    Chojnowska, Sylwia; Minarowska, Alina; Waszkiewicz, Napoleon; Kępka, Alina; Zalewska-Szajda, Beata; Gościk, Elżbieta; Kowal, Krzysztof; Olszewska, Ewa; Konarzewska-Duchnowska, Emilia; Minarowski, Łukasz; Zwierz, Krzysztof; Ładny, Jerzy Robert; Szajda, Sławomir Dariusz

    2014-01-01

    Nasal polyps and hypertrophic lower nasal conchae are common disorders of nasal cavity. The majority of etiopathogenetic theories indicate inflammatory background of polyps and hypertrophic concha. N-acetyl-β-D-hexosaminidase and β-glucuronidase are lysosomal exoglycosidases revealing accelerated activity in inflammatory processes. The aim of the study was to evaluate the catabolism of glycoconjugates in nasal polyps and hypertrophic nasal concha basing on the activity of N-acetyl-β-D-hexosaminidase (HEX) and β-glucuronidase (GLU). Material consisted of nasal polyps taken from 40 patients during polypectomy in patients with chronic rhinosinusitis with nasal polyps (CRSwNP) and hypertrophic lower nasal conchae taken from 20 patients during mucotomy. The activity of HEX, HEX A, HEX B and GLU in supernatant of homogenates of nasal polyps and hypertrophic lower nasal concha tissues has been estimated using colorimetric method. Statistically significant decrease has been observed in concentration of the activity (per 1mg of tissue) of HEX (p<0.05), HEX B (p<0.001) and specific activity (per 1mg of protein) of HEX B (p<0.001) in nasal polyps tissue in comparison to hypertrophic lower nasal conchae tissue. Decrease in the activity and specific activity concentration of the majority of examined lysosomal exoglycosidases (increasing in inflammations) in comparison to hypertrophic lower nasal conchae suggests electrolytes disorders and questions the inflammatory background of nasal polyps. Copyright © 2013 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  7. Observability of planet-disc interactions in CO kinematics

    NASA Astrophysics Data System (ADS)

    Pérez, Sebastián; Casassus, S.; Benítez-Llambay, P.

    2018-06-01

    Empirical evidence of planets in gas-rich circumstellar discs is required to constrain giant planet formation theories. Here we study the kinematic patterns which arise from planet-disc interactions and their observability in CO rotational emission lines. We perform three-dimensional hydrodynamical simulations of single giant planets, and predict the emergent intensity field with radiative transfer. Pressure gradients at planet-carved gaps, spiral wakes and vortices bear strong kinematic counterparts. The iso-velocity contours in the CO(2-1) line centroids vo reveal large-scale perturbations, corresponding to abrupt transitions from below sub-Keplerian to super-Keplerian rotation along with radial and vertical flows. The increase in line optical depth at the edge of the gap also modulates vo, but this is a mild effect compared to the dynamical imprint of the planet-disc interaction. The large-scale deviations from the Keplerian rotation thus allow the planets to be indirectly detected via the first moment maps of molecular gas tracers, at ALMA angular resolutions. The strength of these deviations depends on the mass of the perturber. This initial study paves the way to eventually determine the mass of the planet by comparison with more detailed models.

  8. Distilled water nasal provocation in hyperreactive patients.

    PubMed

    Baudoin, T; Anzic, S A; Kalogjera, L

    1999-01-01

    Nonisotonic aerosol may act as a provocation agent in the upper and lower airways of hyperreactive individuals. The purpose of the study was to compare the results of nasal challenge with distilled water in patients with allergic rhinitis to those with noninfective nonallergic rhinitis (NINAR), with respect to the potential clinical use of the obtained data. A group of 68 ambulatory patients with allergic rhinitis or NINAR (39 perennial allergic, 6 seasonal, 23 NINAR) were challenged with 10 mL of distilled water aerosol after the baseline active anterior rhinomanometry. Patients with nasal polyposis at endoscopy, significant unilateral septal deviation, positive bacteriologic swab, recent nasal surgery, and uncertain anamnestic data about the medication taken 6 weeks before the provocation were excluded from the study. After 10 minutes of nasal provocation, rhinomanometry was repeated to assess the response. In 15 patients of the perennial allergic group, the same measurements were performed after a 2-week oral antihistamine and topical steroid therapy. Nasal resistance was significantly increased on the more patent side of the nose after nasal provocation with distilled water aerosol in allergic patients in comparison to the nasal resistance before provocation. In the patients with NINAR, the provocation resulted in a significant rise on the more patent side, but the total nasal airway resistance (NAR) levels were also significantly increased. The systemic antihistamine and topical steroid 2-week therapy in patients with perennial allergic rhinitis significantly reduced the response to nasal distilled water provocation. Nasal provocation with distilled water aerosol is a cheap, simple, and acceptable method that provides useful clinical data on the level of nonspecific nasal hyperreactivity and the therapy success.

  9. A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements

    NASA Astrophysics Data System (ADS)

    Dennison, Christopher R.; Wild, Peter M.; Wilson, David R.; Cripton, Peter A.

    2008-08-01

    We present an in-fiber Bragg grating (FBG) based intervertebral disc (IVD) pressure sensor that has pressure sensitivity seven times greater than that of a bare fiber, and a major diameter and sensing area of only 400 µm and 0.03 mm2, respectively. This is the only optical, the smallest and the most mechanically compliant disc pressure sensor reported in the literature. This is also an improvement over other FBG pressure sensors that achieve increased sensitivity through mechanical amplification schemes, usually resulting in major diameters and sensing lengths of many millimeters. Sensor sensitivity is predicted using numerical models, and the predicted sensitivity is verified through experimental calibrations. The sensor is validated by conducting IVD pressure measurements in porcine discs and comparing the FBG measurements to those obtained using the current standard sensor for IVD pressure. The predicted sensitivity of the FBG sensor matched with that measured experimentally. IVD pressure measurements showed excellent repeatability and agreement with those obtained from the standard sensor. Unlike the current larger sensors, the FBG sensor could be used in discs with small disc height (i.e. cervical or degenerated discs). Therefore, there is potential to conduct new measurements that could lead to new understanding of the biomechanics.

  10. Nasal microenvironments and interspecific interactions influence nasal microbiota complexity and S. aureus carriage.

    PubMed

    Yan, Miling; Pamp, Sünje J; Fukuyama, Julia; Hwang, Peter H; Cho, Do-Yeon; Holmes, Susan; Relman, David A

    2013-12-11

    The indigenous microbiota of the nasal cavity plays important roles in human health and disease. Patterns of spatial variation in microbiota composition may help explain Staphylococcus aureus colonization and reveal interspecies and species-host interactions. To assess the biogeography of the nasal microbiota, we sampled healthy subjects, representing both S. aureus carriers and noncarriers at three nasal sites (anterior naris, middle meatus, and sphenoethmoidal recess). Phylogenetic compositional and sparse linear discriminant analyses revealed communities that differed according to site epithelium type and S. aureus culture-based carriage status. Corynebacterium accolens and C. pseudodiphtheriticum were identified as the most important microbial community determinants of S. aureus carriage, and competitive interactions were only evident at sites with ciliated pseudostratified columnar epithelium. In vitro cocultivation experiments provided supporting evidence of interactions among these species. These results highlight spatial variation in nasal microbial communities and differences in community composition between S. aureus carriers and noncarriers. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Nasal microenvironments and interspecific interactions influence nasal microbiota complexity and S. aureus carriage

    PubMed Central

    Yan, Miling; Pamp, Sünje J.; Fukuyama, Julia; Hwang, Peter H.; Cho, Do-Yeon; Holmes, Susan; Relman, David A.

    2013-01-01

    Summary The indigenous microbiota of the nasal cavity plays important roles in human health and disease. Patterns of spatial variation in microbiota composition may help explain Staphylococcus aureus colonization, and reveal interspecies and species-host interactions. To assess the biogeography of the nasal microbiota, we sampled healthy subjects, representing both S. aureus carriers and non-carriers, at 3 nasal sites (anterior naris, middle meatus, and sphenoethmoidal recess). Phylogenetic compositional and sparse linear discriminant analyses revealed communities that differed according to site epithelium type and S. aureus culture-based carriage status. Corynebacterium accolens and C. pseudodiphtheriticum were identified as the most important microbial community determinants of S. aureus carriage, with competitive interactions evident only at sites with ciliated pseudostratified columnar epithelium. In vitro co-cultivation experiments provided supporting evidence of interactions among these species. These results highlight spatial variation in nasal microbial communities and differences in community composition between S. aureus carriers and non-carriers. PMID:24331461

  12. Simulating the nasal cycle with computational fluid dynamics

    PubMed Central

    Patel, Ruchin G.; Garcia, Guilherme J. M.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.

    2015-01-01

    Objectives (1) Develop a method to account for the confounding effect of the nasal cycle when comparing pre- and post-surgery objective measures of nasal patency. (2) Illustrate this method by reporting objective measures derived from computational fluid dynamics (CFD) models spanning the full range of mucosal engorgement associated with the nasal cycle in two subjects. Study Design Retrospective Setting Academic tertiary medical center. Subjects and Methods A cohort of 24 nasal airway obstruction patients was reviewed to select the two patients with the greatest reciprocal change in mucosal engorgement between pre- and post-surgery computed tomography (CT) scans. Three-dimensional anatomic models were created based on the pre- and post-operative CT scans. Nasal cycling models were also created by gradually changing the thickness of the inferior turbinate, middle turbinate, and septal swell body. CFD was used to simulate airflow and to calculate nasal resistance and average heat flux. Results Before accounting for the nasal cycle, Patient A appeared to have a paradoxical worsening nasal obstruction in the right cavity postoperatively. After accounting for the nasal cycle, Patient A had small improvements in objective measures postoperatively. The magnitude of the surgical effect also differed in Patient B after accounting for the nasal cycle. Conclusion By simulating the nasal cycle and comparing models in similar congestive states, surgical changes in nasal patency can be distinguished from physiological changes associated with the nasal cycle. This ability can lead to more precise comparisons of pre and post-surgery objective measures and potentially more accurate virtual surgery planning. PMID:25450411

  13. A novel collinear optical system with annulus mirrors for holographic disc driver

    NASA Astrophysics Data System (ADS)

    Wang, Ye

    2008-12-01

    This paper focus on a novel collinear lens system with annulus mirrors for holographic disc driver, both information beam and reference beam are use same laser beam. The expanded and parallel laser beam, center part of it as the information beam then through Fourier transform lens, the beam around center part as a reference beam. On this axis, the ring reference beam reflected by two annulus shaped mirrors, then became a convergent beam, together with the information beam which through the first Fourier transform lens then produce holographic pattern to be write into the holographic disc behind of them, this lens system with two mirrors made the angle between information beam and reference beam more wide, can improved the multiplex level of holographic storage. Pair of Fourier transform lens with advance performance is designed in this paper.

  14. Yb:YAG disc for high energy laser systems

    NASA Astrophysics Data System (ADS)

    Nejezchleb, Karel; Kubát, Jan; Å ulc, Jan; Jelínková, Helena

    2017-02-01

    Large Yb:YAG crystals were grown using of new improved technology enabling to produce YAG crystals without central growth defect. The crystals diameter reached 115-120mm and their central part was used for manufacturing of discs with the diameter larger than 55 mm. Both sides of this discs were polished and coated. Doping concentration of Yb3+ ions in Yb:YAG crystals was measured using of X-ray fluorescence spectrometry. Absorption coefficient of Yb:YAG was measured for different doping concentration of Yb3+ ions. Fluorescence decay time of Yb:YAG was measured at temperatures of 300K and 80 K. We found the fluorescence decay time of the values of 0.95-1 ms at both temperatures stable and independent on the Yb3+ doping concentration in the range of 1-10 at.% Yb/Y demonstrating high chemical purity of grown crystals. Optical homogeneity as measured using of Fizeau double pass interferometer at 633nm resulted with PV values lower than 0.15 λ on clear aperture of 35 mm. Polished surfaces were ideally parallel with the wedge lower than 2 arcsec. Uniformity of laser properties of Yb:YAG was verified by scanning of the disc as active media in plan-convex pulsed laser resonator pumped by semiconductor diode (wavelength 969 nm, pumping beam diameter 100 μm). It was confirmed, that newly developed technology allows to manufacture very large high quality Yb:YAG discs suitable for high power lasers and amplifiers.

  15. [Clinical analysis of nasal mucosa contact headache].

    PubMed

    Gu, Qingjia; Wen, Bei; Li, Jingxian; Fan, Jiangang; He, Gang

    2013-07-01

    To investigate the efficacy of nasal mucosa contact point headache with the treatment of endoscopic sinus surgery. Clinical data of 75 cases with nasal mucosa contact point headache treated in our department from Jan 2008 to Nov 2011 were retrospectively analyzed. These patients were performed with endoscopic sinus surgery. All patients were followed up for more than six months. They all achieved significant efficacy and no complications occurred. Nasal mucosa contact point headache and primary headache had different clinical features and different treatment. Misdiagnosis were easily made if not being carefully analyzed. Three lines tension relaxing septorhinoplasty combined with nasal bone fracture correction can achieve satisfactory curative effect and can effectively prevent the occurrence of complications. Therefore, it is necessary to strengthen the awareness of this disease. Nasal structure abnormality is the main reason of nasal mucosa contact point headache. The implementation of individualized nasal endoscopic sinus surgery can achieve satisfactory curative effect.

  16. Rethinking Black Hole Accretion Discs

    NASA Astrophysics Data System (ADS)

    Salvesen, Greg

    Accretion discs are staples of astrophysics. Tapping into the gravitational potential energy of the accreting material, these discs are highly efficient machines that produce copious radiation and extreme outflows. While interesting in their own right, accretion discs also act as tools to study black holes and directly influence the properties of the Universe. Black hole X-ray binaries are fantastic natural laboratories for studying accretion disc physics and black hole phenomena. Among many of the curious behaviors exhibited by these systems are black hole state transitions -- complicated cycles of dramatic brightening and dimming. Using X-ray observations with high temporal cadence, we show that the evolution of the accretion disc spectrum during black hole state transitions can be described by a variable disc atmospheric structure without invoking a radially truncated disc geometry. The accretion disc spectrum can be a powerful diagnostic for measuring black hole spin if the effects of the disc atmosphere on the emergent spectrum are well-understood; however, properties of the disc atmosphere are largely unconstrained. Using statistical methods, we decompose this black hole spin measurement technique and show that modest uncertainties regarding the disc atmosphere can lead to erroneous spin measurements. The vertical structure of the disc is difficult to constrain due to our ignorance of the contribution to hydrostatic balance by magnetic fields, which are fundamental to the accretion process. Observations of black hole X-ray binaries and the accretion environments near supermassive black holes provide mounting evidence for strong magnetization. Performing numerical simulations of accretion discs in the shearing box approximation, we impose a net vertical magnetic flux that allows us to effectively control the level of disc magnetization. We study how dynamo activity and the properties of turbulence driven by the magnetorotational instability depend on the

  17. How do accretion discs break?

    NASA Astrophysics Data System (ADS)

    Dogan, Suzan

    2016-07-01

    Accretion discs are common in binary systems, and they are often found to be misaligned with respect to the binary orbit. The gravitational torque from a companion induces nodal precession in misaligned disc orbits. In this study, we first calculate whether this precession is strong enough to overcome the internal disc torques communicating angular momentum. We compare the disc precession torque with the disc viscous torque to determine whether the disc should warp or break. For typical parameters precession wins: the disc breaks into distinct planes that precess effectively independently. To check our analytical findings, we perform 3D hydrodynamical numerical simulations using the PHANTOM smoothed particle hydrodynamics code, and confirm that disc breaking is widespread and enhances accretion on to the central object. For some inclinations, the disc goes through strong Kozai cycles. Disc breaking promotes markedly enhanced and variable accretion and potentially produces high-energy particles or radiation through shocks. This would have significant implications for all binary systems: e.g. accretion outbursts in X-ray binaries and fuelling supermassive black hole (SMBH) binaries. The behaviour we have discussed in this work is relevant to a variety of astrophysical systems, for example X-ray binaries, where the disc plane may be tilted by radiation warping, SMBH binaries, where accretion of misaligned gas can create effectively random inclinations and protostellar binaries, where a disc may be misaligned by a variety of effects such as binary capture/exchange, accretion after binary formation.

  18. Laser speckle flowgraphy for differentiating between nonarteritic ischemic optic neuropathy and anterior optic neuritis.

    PubMed

    Maekubo, Tomoyuki; Chuman, Hideki; Nao-I, Nobuhisa

    2013-07-01

    The aim of this study was to investigate the usefulness of laser speckle flowgraphy (LSFG) for the differentiation of acute nonarteritic ischemic optic neuropathy (NAION) from anterior optic neuritis (ON). To investigate blood flow in the optic disc under normal conditions, NAION, and anterior ON, we compared the tissue blood flow of the right eye with that of the left eye in the control group, and that of the affected eye with that of the unaffected eye in the NAION and anterior ON groups. In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had decreased optic disc blood flow in the NAION eye when compared with the unaffected eye. By contrast, in the anterior ON group, all 6 patients had increased optic disc blood flow in the anterior ON eye when compared with the unaffected eye. In the NAION group, the mean blur rate (MBR) of the affected eyes was 29.5 % lower than that of the unaffected eyes. In the anterior ON group, the MBR of the affected eyes was 15.9 % higher than that of the unaffected eyes. LSFG could be useful in differentiating between NAION and anterior ON. In addition, this imaging technique saves time and is noninvasive.

  19. The new agreement of the international RIGA consensus conference on nasal airway function tests.

    PubMed

    Vogt, K; Bachmann-Harildstad, G; Lintermann, A; Nechyporenko, A; Peters, F; Wernecke, K D

    2018-01-21

    The report reflects an agreement based on the consensus conference of the International Standardization Committee on the Objective Assessment of the Nasal Airway in Riga, 2nd Nov. 2016. The aim of the conference was to address the existing nasal airway function tests and to take into account physical, mathematical and technical correctness as a base of international standardization as well as the requirements of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices. Rhinomanometry, acoustic rhinometry, peak nasal inspiratory flow, Odiosoft-Rhino, optical rhinometry, 24-h measurements, computational fluid dynamics, nasometry and the mirrow test were evaluated for important diagnostic criteria, which are the precision of the equipment including calibration and the software applied; validity with sensitivity, specificity, positive and negative predictive values, reliability with intra-individual and inter-individual reproducibility and responsiveness in clinical studies. For rhinomanometry, the logarithmic effective resistance was set as the parameter of high diagnostic relevance. In acoustic rhinometry, the area of interest for the minimal cross-sectional area will need further standardization. Peak nasal inspiratory flow is a reproducible and fast test, which showed a high range of mean values in different studies. The state of the art with computational fluid dynamics for the simulation of the airway still depends on high performance computing hardware and will, after standardization of the software and both the software and hardware for imaging protocols, certainly deliver a better understanding of the nasal airway flux.

  20. Macular slippage after macular hole surgery with internal limiting membrane peeling.

    PubMed

    Nakagomi, Tomomi; Goto, Teruhiko; Tateno, Yasushi; Oshiro, Tomohiro; Iijima, Hiroyuki

    2013-12-01

    To describe macular slippage toward the optic disc after macular hole surgery with internal limiting membrane (ILM) peeling. A total of 27 eyes of 27 patients with idiopathic macular hole were included in this retrospective study. The fovea-to-disc distance (FDD) was measured from digital color fundus images before and at least six months after surgery. The position of the fovea was determined as the center of the macular hole before surgery and the center of the macular pigment area after surgery. The thickness of the nasal and temporal macula was measured using spectral-domain optical coherence tomography. The difference in thickness between the nasal and temporal macula was determined as the degree of parafoveal asymmetry (PFA). The postoperative FDD was significantly shorter than the preoperative FDD: 4.00 ± 0.33 mm and 3.82 ± 0.34 mm, respectively (p < 0.0001). The mean decreased ratio of FDD was 4.68% (range, 0.38-9.24%). The appearance of the dissociated optic nerve fiber layer (DONFL) was finally found in 21 eyes (78%). The decreased FDD ratio was significantly larger in eyes with the DONFL appearance than in those without it: 5.61 ± 1.74% and 1.44 ± 1.12%, respectively (p < 0.0001). The decreased ratio of FDD was correlated with the postoperative PFA (r = 0.63, p = 0.0004). A macula in which the ILM has peeled off would slip toward the optic disc after macular hole surgery. Macular slippage can be a reasonable cause for the macular alterations such as an appearance of DONFL and changes in asymmetrical parafoveal thickness.

  1. SDSS-IV MaNGA: constraints on the conditions for star formation in galaxy discs

    NASA Astrophysics Data System (ADS)

    Stark, David V.; Bundy, Kevin A.; Orr, Matthew E.; Hopkins, Philip F.; Westfall, Kyle; Bershady, Matthew; Li, Cheng; Bizyaev, Dmitry; Masters, Karen L.; Weijmans, Anne-Marie; Lacerna, Ivan; Thomas, Daniel; Drory, Niv; Yan, Renbin; Zhang, Kai

    2018-02-01

    Regions of disc galaxies with widespread star formation tend to be both gravitationally unstable and self-shielded against ionizing radiation, whereas extended outer discs with little or no star formation tend to be stable and unshielded on average. We explore what drives the transition between these two regimes, specifically whether discs first meet the conditions for self-shielding (parametrized by dust optical depth, τ) or gravitational instability (parametrized by a modified version of Toomre's instability parameters, Qthermal, which quantifies the stability of a gas disc that is thermally supported at T = 104 K). We first introduce a new metric formed by the product of these quantities, Qthermalτ, which indicates whether the conditions for disc instability or self-shielding are easier to meet in a given region of a galaxy, and we discuss how Qthermalτ can be constrained even in the absence of direct gas information. We then analyse a sample of 13 galaxies with resolved gas measurements and find that on average galaxies will reach the threshold for disc instabilities (Qthermal < 1) before reaching the threshold for self-shielding (τ > 1). Using integral field spectroscopic observations of a sample of 236 galaxies from the Mapping Nearby Galaxies at APO (MaNGA) survey, we find that the value of Qthermalτ in star-forming discs is consistent with similar behaviour. These results support a scenario where disc fragmentation and collapse occurs before self-shielding, suggesting that gravitational instabilities are the primary condition for widespread star formation in galaxy discs. Our results support similar conclusions based on recent galaxy simulations.

  2. Nasal Drug Delivery in Traditional Persian Medicine

    PubMed Central

    Zarshenas, Mohammad Mehdi; Zargaran, Arman; Müller, Johannes; Mohagheghzadeh, Abdolali

    2013-01-01

    Background Over one hundred different pharmaceutical dosage forms have been recorded in literatures of Traditional Persian Medicine among which nasal forms are considerable. Objectives This study designed to derive the most often applied nasal dosage forms together with those brief clinical administrations. Materials and Methods In the current study remaining pharmaceutical manuscripts of Persia during 9th to 18th century AD have been studied and different dosage forms related to nasal application of herbal medicines and their therapeutic effects were derived. Results By searching through pharmaceutical manuscripts of medieval Persia, different nasal dosage forms involving eleven types related to three main groups are found. These types could be derived from powder, solution or liquid and gaseous forms. Gaseous form were classified into fumigation (Bakhoor), vapor bath (Enkebab), inhalation (Lakhlakheh), aroma agents (Ghalieh) and olfaction or smell (Shomoom). Nasal solutions were as drops (Ghatoor), nasal snuffing drops (Saoot) and liquid snuff formulations (Noshoogh). Powders were as nasal insufflation or snorting agents (Nofookh) and errhine or sternutator medicine (Otoos). Nasal forms were not applied only for local purposes. Rather systemic disorders and specially CNS complications were said to be a target for these dosage forms. Discussion While this novel type of drug delivery is known as a suitable substitute for oral and parenteral administration, it was well accepted and extensively mentioned in Persian medical and pharmaceutical manuscripts and other traditional systems of medicine as well. Accordingly, medieval pharmaceutical standpoints on nasal dosage forms could still be an interesting subject of study. Therefore, the current work can briefly show the pharmaceutical knowledge on nasal formulations in medieval Persia and clarify a part of history of traditional Persian pharmacy. PMID:24624204

  3. Simultaneous optical/X-ray study of GS 1354-64 (=BW Cir) during hard outburst: evidence for optical cyclo-synchrotron emission from the hot accretion flow

    NASA Astrophysics Data System (ADS)

    Pahari, Mayukh; Gandhi, Poshak; Charles, Philip A.; Kotze, Marissa M.; Altamirano, Diego; Misra, Ranjeev

    2017-07-01

    We present results from simultaneous optical [South African Large Telescope (SALT)] and X-ray (Swift and INTEGRAL) observations of GS 1354-64/BW Cir during the 2015 hard state outburst. During the rising phase, optical/X-ray time series shows a strong anti-correlation with X-ray photons lagging optical. Optical and X-ray power spectra show quasi-periodic oscillations (QPOs) at a frequency of ˜18 mHz with a confidence level of at least 99 per cent. Simultaneous fitting of Swift/XRT and INTEGRAL spectra in the range 0.5-1000.0 keV shows non-thermal, power-law-dominated (>90 per cent) spectra with a hard power-law index of 1.48 ± 0.03, inner disc temperature of 0.12 ± 0.01 keV and an inner disc radius of ˜3000 km. All evidence is consistent with cyclo-synchrotron radiation in a non-thermal, hot electron cloud extending to ˜100 Schwarzschild radii being a major physical process for the origin of optical photons. At outburst peak about one month later, when the X-ray flux rises and the optical drops, the apparent features in the optical/X-ray correlation vanish and the optical auto correlation widens. Although ˜0.19 Hz QPO is observed from the X-ray power spectra, the optical variability is dominated by the broad-band noise, and the inner disc temperature increases. These results support a change in the dominant optical emission source between outburst rise and peak, consistent with a weakening of hot flow as the disc moves in.

  4. Adalimumab and Non-Arteritic Anterior Ischaemic Optic Neuropathy: A Case Report.

    PubMed

    Kinard, Krista; Walsh, Jessica A; Penmetsa, Gopi K; Warner, Judith E A

    2014-01-01

    Sequential anterior ischaemic optic neuropathy was observed in a patient treated with a tumour necrosis factor α (TNF) inhibitor, adalimumab, for ankylosing spondylitis. He developed decreased visual acuity in the right eye after 17 months of treatment. Findings showed right optic disc oedema with haemorrhages and visual field defect. Adalimumab was discontinued and vision stabilised. After restarting adalimumab, he developed optic neuropathy in the left eye. Findings showed optic disc oedema, with haemorrhages and visual field changes in the left eye. Adalimumab may be associated with optic neuropathy; providers prescribing TNF inhibitors should be aware of optic neuropathy as a potential complication.

  5. Numerical simulation and nasal air-conditioning

    PubMed Central

    Keck, Tilman; Lindemann, Jörg

    2011-01-01

    Heating and humidification of the respiratory air are the main functions of the nasal airways in addition to cleansing and olfaction. Optimal nasal air conditioning is mandatory for an ideal pulmonary gas exchange in order to avoid desiccation and adhesion of the alveolar capillary bed. The complex three-dimensional anatomical structure of the nose makes it impossible to perform detailed in vivo studies on intranasal heating and humidification within the entire nasal airways applying various technical set-ups. The main problem of in vivo temperature and humidity measurements is a poor spatial and time resolution. Therefore, in vivo measurements are feasible only to a restricted extent, solely providing single temperature values as the complete nose is not entirely accessible. Therefore, data on the overall performance of the nose are only based on one single measurement within each nasal segment. In vivo measurements within the entire nose are not feasible. These serious technical issues concerning in vivo measurements led to a large number of numerical simulation projects in the last few years providing novel information about the complex functions of the nasal airways. In general, numerical simulations merely calculate predictions in a computational model, e.g. a realistic nose model, depending on the setting of the boundary conditions. Therefore, numerical simulations achieve only approximations of a possible real situation. The aim of this review is the synopsis of the technical expertise on the field of in vivo nasal air conditioning, the novel information of numerical simulations and the current state of knowledge on the influence of nasal and sinus surgery on nasal air conditioning. PMID:22073112

  6. A new approach to the treatment of nasal bone fracture: radiologic classification of nasal bone fractures and its clinical application.

    PubMed

    Han, Daniel Seung Youl; Han, Yea Sik; Park, Jin Hyung

    2011-11-01

    A radiologic examination is required in the treatment of nasal bone fracture to determine the fracture condition. Thus, there is an increasing need for radiologic classification of nasal bone fractures that can be applied to clinical practice. Computed tomography was performed in 125 patients with nasal bone fractures to determine which axial view best showed the entire nasal view. The obtained axial view was then used as a reference for classification. The length from the top to the base of the nasal bone was divided into upper, middle, and lower levels, after which the fracture location was determined. If the fracture spanned the boundaries of these levels, it was classified as the total level. Subsequently, the fracture was subclassified based on the fracture direction and pattern and the concurrent fracture. Radiologic examination of patients with nasal bone fracture showed that nasal bone fracture was frequently found at the total, middle, upper, and lower levels, in that order. Nasal bone fractures at the upper level showed lower frequencies of complication and reoperation than the fractures at the other levels, whereas nasal bone fractures at the total level showed the highest frequencies of complication and reoperation. Radiologic classification can be useful for preoperative and postoperative evaluations of nasal bone fractures and can be helpful in understanding such fractures because it can efficiently predict the prognosis of a fracture. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Nasal and Oral Inspiration During Natural Speech Breathing

    PubMed Central

    Lester, Rosemary A.; Hoit, Jeannette D.

    2015-01-01

    Purpose The purpose of this study was to determine the typical pattern for inspiration during speech breathing in healthy adults, as well as the factors that might influence it. Method Ten healthy adults, 18–45 years of age, performed a variety of speaking tasks while nasal ram pressure, audio, and video recordings were obtained. Inspirations were categorized as a nasal only, oral only, simultaneous nasal and oral, or alternating nasal and oral inspiration. The method was validated using nasal airflow, oral airflow, audio, and video recordings for two participants. Results The predominant pattern was simultaneous nasal and oral inspirations for all speaking tasks. This pattern was not affected by the nature of the speaking task or by the phonetic context surrounding the inspiration. The validation procedure confirmed that nearly all inspirations during counting and paragraph reading were simultaneous nasal and oral inspirations; whereas for sentence reading, the predominant pattern was alternating nasal and oral inspirations across the three phonetic contexts. Conclusions Healthy adults inspire through both the nose and mouth during natural speech breathing. This pattern of inspiration is likely beneficial in reducing pathway resistance while preserving some of the benefits of nasal breathing. PMID:24129013

  8. Preparation of ormetoprim-sulfadimethoxine-medicated discs for disc diffusion assay

    USDA-ARS?s Scientific Manuscript database

    Romet ( a blend of ormetoprim and sulfadimethoxine) is a type A medicated article for the manufacture of medicated feed in the catfish industry. Recently, the commercial manufacture of ormetoprim-sulfadimethoxine susceptibility discs was discontinued. Ormetoprim-sulfadimethoxine discs were prepare...

  9. X-ray and multiwavelength insights into the inner structure of high-luminosity disc-like emitters

    NASA Astrophysics Data System (ADS)

    Luo, B.; Brandt, W. N.; Eracleous, M.; Wu, Jian; Hall, P. B.; Rafiee, A.; Schneider, D. P.; Wu, Jianfeng

    2013-02-01

    We present X-ray and multiwavelength studies of a sample of eight high-luminosity active galactic nuclei (AGN) with disc-like Hβ emission-line profiles selected from the Sloan Digital Sky Survey Data Release 7. These sources have higher redshift (z ≈ 0.6) than the majority of the known disc-like emitters, and they occupy a largely unexplored space in the luminosity-redshift plane. Seven sources have typical AGN X-ray spectra with power-law photon indices of Γ ≈ 1.4-2.0; two of them show some X-ray absorption (column density NH ≈ 1021-1022 cm-2 for neutral gas). The other source, J0850+4451, has only three hard X-ray photons detected and is probably heavily obscured (NH ≳ 3 × 1023 cm-2). This object is also identified as a low-ionization broad absorption line (BAL) quasar based on Mg II λ2799 absorption; it is the first disc-like emitter reported that is also a BAL quasar. The infrared-to-ultraviolet (UV) spectral energy distributions (SEDs) of these eight sources are similar to the mean SEDs of typical quasars with a UV `bump', suggestive of standard accretion discs radiating with high efficiency, which differs from low-luminosity disc-like emitters. Studies of the X-ray-to-optical power-law slope parameters (αOX) indicate that there is no significant excess X-ray emission in these high-luminosity disc-like emitters. Energy budget analysis suggests that for disc-like emitters in general, the inner disc must illuminate and ionize the outer disc efficiently (≈15 per cent of the nuclear ionizing radiation is required on average) via direct illumination and/or scattering. Warped accretion discs are probably needed for direct illumination to work in high-luminosity objects, as their geometrically thin inner discs decrease the amount of direct illumination possible for a flat disc.

  10. Preparation of ormetoprim sulfadimethoxine medicated discs for disc diffusion assay

    USDA-ARS?s Scientific Manuscript database

    Romet (a blend of ormetoprim and sulfadimethoxine) is a typeA medicated article for the manufacture of medicated feed in the catfish industry. Recently, the commercial manufacture of ormetoprim–sulfadimethoxine susceptibility discs was discontinued. Ormetoprim–sulfadimethoxine discs were prepared at...

  11. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and

  12. Phenotype and function of nasal dendritic cells

    PubMed Central

    Lee, Haekyung; Ruane, Darren; Law, Kenneth; Ho, Yan; Garg, Aakash; Rahman, Adeeb; Esterházy, Daria; Cheong, Cheolho; Goljo, Erden; Sikora, Andrew G.; Mucida, Daniel; Chen, Benjamin; Govindraj, Satish; Breton, Gaëlle; Mehandru, Saurabh

    2015-01-01

    Intranasal vaccination generates immunity across local, regional and distant sites. However, nasal dendritic cells (DC), pivotal for the induction of intranasal vaccine- induced immune responses, have not been studied in detail. Here, using a variety of parameters, we define nasal DCs in mice and humans. Distinct subsets of “classical” DCs, dependent on the transcription factor zbtb46 were identified in the murine nose. The murine nasal DCs were FLT3 ligand-responsive and displayed unique phenotypic and functional characteristics including the ability to present antigen, induce an allogeneic T cell response and migrate in response to LPS or live bacterial pathogens. Importantly, in a cohort of human volunteers, BDCA-1+ DCs were observed to be the dominant nasal DC population at steady state. During chronic inflammation, the frequency of both BDCA-1+ and BDCA-3hi DCs was reduced in the nasal tissue, associating the loss of these immune sentinels with chronic nasal inflammation. The present study is the first detailed description of the phenotypic, ontogenetic and functional properties of nasal DCs and will inform the design of preventative immunization strategies as well as therapeutic modalities against chronic rhinosinusitis. PMID:25669151

  13. Interactive Visualization of a Thin Disc around a Schwarzschild Black Hole

    ERIC Educational Resources Information Center

    Muller, Thomas; Frauendiener, Jorg

    2012-01-01

    In a first course in general relativity, the Schwarzschild spacetime is the most discussed analytic solution to Einstein's field equations. Unfortunately, there is rarely enough time to study the optical consequences of the bending of light for some advanced examples. In this paper, we present how the visual appearance of a thin disc around a…

  14. Regional deposition of mometasone furoate nasal spray suspension in humans.

    PubMed

    Shah, Samir A; Berger, Robert L; McDermott, John; Gupta, Pranav; Monteith, David; Connor, Alyson; Lin, Wu

    2015-01-01

    Nasal deposition studies can demonstrate whether nasal sprays treating allergic rhinitis and polyposis reach the ciliated posterior nasal cavity, where turbinate inflammation and other pathology occurs. However, quantifying nasal deposition is challenging, because in vitro tests do not correlate to human nasal deposition; gamma scintigraphy studies are thus used. For valid data, the radiolabel must distribute, as the drug, into different-sized droplets, remain associated with the drug in the formulation after administration, and not alter its deposition. Some nasal deposition studies have demonstrated this using homogenous solutions. However, most commercial nasal sprays are heterogeneous suspensions. Using mometasone furoate nasal suspension (MFS), we developed a technique to validate radiolabel deposition as a surrogate for nasal cavity drug deposition and characterized regional deposition and nasal clearance in humans. Mometasone furoate (MF) formulation was spiked with diethylene triamine pentacaetic acid. Both unlabeled and radiolabeled formulations (n = 3) were sprayed into a regionally divided nasal cast. Drug deposition was quantified by high pressure liquid chromatography within each region; radiolabel deposition was determined by gamma camera. Healthy subjects (n = 12) were dosed and imaged for six hours. Scintigraphic images were coregistered with magnetic resonance imaging scans to quantify anterior and posterior nasal cavity deposition and mucociliary clearance. The ratio of radiolabel to unlabeled drug was 1.05 in the nasal cast and regionally appeared to match, indicating that in vivo radiolabel deposition could represent drug deposition. In humans, MFS delivered 86% (9.2) of metered dose to the nasal cavity, approximately 60% (9.1) of metered dose to the posterior nasal cavity. After 15 minutes, mucociliary clearance removed 59% of the initial radiolabel in the nasal cavity, consistent with clearance rates from the ciliated posterior surface. MFS

  15. Regional deposition of mometasone furoate nasal spray suspension in humans.

    PubMed

    Shah, S A; Berger, R L; McDermott, J; Gupta, P; Monteith, D; Connor, A; Lin, W

    2014-11-21

    Nasal deposition studies can demonstrate whether nasal sprays treating allergic rhinitis and polyposis reach the ciliated posterior nasal cavity, where turbinate inflammation and other pathology occurs. However, quantifying nasal deposition is challenging, because in vitro tests do not correlate to human nasal deposition; gamma scintigraphy studies are thus used. For valid data, the radiolabel must distribute, as the drug, into different-sized droplets, remain associated with the drug in the formulation after administration, and not alter its deposition. Some nasal deposition studies have demonstrated this using homogenous solutions. However, most commercial nasal sprays are heterogeneous suspensions. Using mometasone furoate nasal suspension (MFS), we developed a technique to validate radiolabel deposition as a surrogate for nasal cavity drug deposition and characterized regional deposition and nasal clearance in humans. Mometasone furoate (MF) formulation was spiked with diethylene triamine pentacaetic acid. Both unlabeled and radiolabeled formulations (n = 3) were sprayed into a regionally divided nasal cast. Drug deposition was quantified by high pressure liquid chromatography within each region; radiolabel deposition was determined by gamma camera. Healthy subjects (n = 12) were dosed and imaged for six hours. Scintigraphic images were coregistered with magnetic resonance imaging scans to quantify anterior and posterior nasal cavity deposition and mucociliary clearance. The ratio of radiolabel to unlabeled drug was 1.05 in the nasal cast and regionally appeared to match, indicating that in vivo radiolabel deposition could represent drug deposition. In humans, MFS delivered 86% (9.2) of metered dose to the nasal cavity, approximately 60% (9.1) of metered dose to the posterior nasal cavity. After 15 minutes, mucociliary clearance removed 59% of the initial radiolabel in the nasal cavity, consistent with clearance rates from the ciliated posterior surface. MFS

  16. A Cost-Effectiveness Analysis of Nasal Surgery to Increase Continuous Positive Airway Pressure Adherence in Sleep Apnea Patients With Nasal Obstruction

    PubMed Central

    Kempfle, Judith S.; BuSaba, Nicholas Y.; Dobrowski, John M.; Westover, Michael B.; Bianchi, Matt T.

    2017-01-01

    Objectives/Hypothesis Nasal surgery has been implicated to improve continuous positive airway pressure (CPAP) compliance in patients with obstructive sleep apnea (OSA) and nasal obstruction. However, the cost-effectiveness of nasal surgery to improve CPAP compliance is not known. We modeled the cost-effectiveness of two types of nasal surgery versus no surgery in patients with OSA and nasal obstruction undergoing CPAP therapy. Study Design Cost-effectiveness decision tree model. Methods We built a decision tree model to identify conditions under which nasal surgery would be cost-effective to improve CPAP adherence over the standard of care. We compared turbinate reduction and septoplasty to nonsurgical treatment over varied time horizons from a third-party payer perspective. We included variables for cost of untreated OSA, surgical cost and complications, improved compliance postoperatively, and quality of life. Results Our study identified nasal surgery as a cost-effective strategy to improve compliance of OSA patients using CPAP across a range of plausible model assumptions regarding the cost of untreated OSA, the probability of adherence improvement, and a chronic time horizon. The relatively lower surgical cost of turbinate reduction made it more cost-effective at earlier time horizons, whereas septoplasty became cost-effective after a longer timespan. Conclusions Across a range of plausible values in a clinically relevant decision model, nasal surgery is a cost-effective strategy to improve CPAP compliance in OSA patients with nasal obstruction. Our results suggest that OSA patients with nasal obstruction who struggle with CPAP therapy compliance should undergo evaluation for nasal surgery. PMID:27653626

  17. Nasal Chondromesenchymal Hamartoma in a Child

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finitsis, Stefanos; Giavroglou, Constantinos; Potsi, Stamatia, E-mail: matinapotsi@hotmail.co

    Nasal chondromesenchymal hamartoma (NCMH) is a benign tumor that was described in 1998. The occurrence of this lesion in the nasal cavity of infants and children is especially rare, with only 21 cases reported in the international literature. We report a 12-month-old boy with respiratory distress due to nasal obstruction. Computed tomographic scan and magnetic resonance imaging examination demonstrated a soft-tissue mass obstructing the left nasal cavity. Digital subtraction angiography and preoperative superselective embolization with microparticles were also performed. The tumor was completely resected surgically. Histopathology and immunohistochemical analyses of the tumor disclosed a NCMH. The imaging characteristics of themore » tumor are described and the radiology literature is reviewed.« less

  18. Assessment of the effect of deviated nasal septum on the structure of nasal cavity.

    PubMed

    Wang, Junguo; Dou, Xin; Liu, Dingding; Song, Panpan; Qian, Xiaoyun; Wang, Shoulin; Gao, Xia

    2016-06-01

    The present study was aimed to investigate the effects of DNS on the structure of nasal cavity. The paranasal sinus coronal view CT of 108 patients with DNS and 129 hospitalized patients without DNS was retrospectively analyzed. The transverse diameter of nasal cavity (a), transverse diameter of nasal cavity and paranasal sinus (b), angle between maxillary and palatal bone, interalveolar distance, and maxillary rotation distance were measured. The ratio of a/b in experimental group was 0.367 ± 0.006 which was significantly (P = 0.0023) less than that in control group (0.391 ± 0.005). For the angle between maxillary and palatal bone, there was no significant difference found between DNS and control group for both right and left sides. The interalveolar distance was 40.75 mm in experimental group, and 38.8 mm in control (P = 0.0002). For the maxillary rotation distance, findings were considered as significant (P < 0.0001) in experimental group (11.25 mm) compared with control (10.1 mm). The present study demonstrates that long-term DNS affects the development of nasal cavity and paranasal sinus, as well as increases the interalveolar distance and maxillary rotation distance. These influences may be caused by the alteration of airflow inside the nasal cavities.

  19. Optic nerve lesion following neuroborreliosis: a case report.

    PubMed

    Burkhard, C; Gleichmann, M; Wilhelm, H

    2001-01-01

    Neuroborreliosis may cause various neuro-ophthalmological complications. We describe a case with a bilateral optic neuropathy. A 58-year-old female developed facial paresis six weeks after an insect bite. One week later she developed bilateral optic disc swelling with haemorrhages and nerve fibre bundle defects in the lower visual field of the left eye. In CSF and serum, raised IgM and IgG titres to Borrelia burgdorferi were found. Systemic antibiotic treatment led to improvement of the vision and facial paresis, but not all visual field defects resolved, probably due to ischemic lesions of the optic disc. In optic nerve lesions due to neuroborreliosis it is difficult to distinguish between inflammatory and ischemic lesions. This patient demonstrated features of an ischemic optic nerve lesion.

  20. Characterization of deposition from nasal spray devices using a computational fluid dynamics model of the human nasal passages.

    PubMed

    Kimbell, Julia S; Segal, Rebecca A; Asgharian, Bahman; Wong, Brian A; Schroeter, Jeffry D; Southall, Jeremy P; Dickens, Colin J; Brace, Geoff; Miller, Frederick J

    2007-01-01

    Many studies suggest limited effectiveness of spray devices for nasal drug delivery due primarily to high deposition and clearance at the front of the nose. Here, nasal spray behavior was studied using experimental measurements and a computational fluid dynamics model of the human nasal passages constructed from magnetic resonance imaging scans of a healthy adult male. Eighteen commercially available nasal sprays were analyzed for spray characteristics using laser diffraction, high-speed video, and high-speed spark photography. Steadystate, inspiratory airflow (15 L/min) and particle transport were simulated under measured spray conditions. Simulated deposition efficiency and spray behavior were consistent with previous experimental studies, two of which used nasal replica molds based on this nasal geometry. Deposition fractions (numbers of deposited particles divided by the number released) of 20- and 50-microm particles exceeded 90% in the anterior part of the nose for most simulated conditions. Predicted particle penetration past the nasal valve improved when (1) the smaller of two particle sizes or the lower of two spray velocities was used, (2) the simulated nozzle was positioned 1.0 rather than 0.5 or 1.5 cm into the nostril, and (3) inspiratory airflow was present rather than absent. Simulations also predicted that delaying the appearance of normal inspiratory airflow more than 1 sec after the release of particles produced results equivalent to cases in which no inspiratory airflow was present. These predictions contribute to more effective design of drug delivery devices through a better understanding of the effects of nasal airflow and spray characteristics on particle transport in the nose.

  1. Gas in the protoplanetary disc of HD 169142: Herschel's view

    NASA Astrophysics Data System (ADS)

    Meeus, G.; Pinte, C.; Woitke, P.; Montesinos, B.; Mendigutía, I.; Riviere-Marichalar, P.; Eiroa, C.; Mathews, G. S.; Vandenbussche, B.; Howard, C. D.; Roberge, A.; Sandell, G.; Duchêne, G.; Ménard, F.; Grady, C. A.; Dent, W. R. F.; Kamp, I.; Augereau, J. C.; Thi, W. F.; Tilling, I.; Alacid, J. M.; Andrews, S.; Ardila, D. R.; Aresu, G.; Barrado, D.; Brittain, S.; Ciardi, D. R.; Danchi, W.; Fedele, D.; de Gregorio-Monsalvo, I.; Heras, A.; Huelamo, N.; Krivov, A.; Lebreton, J.; Liseau, R.; Martin-Zaidi, C.; Mora, A.; Morales-Calderon, M.; Nomura, H.; Pantin, E.; Pascucci, I.; Phillips, N.; Podio, L.; Poelman, D. R.; Ramsay, S.; Riaz, B.; Rice, K.; Solano, E.; Walker, H.; White, G. J.; Williams, J. P.; Wright, G.

    2010-07-01

    In an effort to simultaneously study the gas and dust components of the disc surrounding the young Herbig Ae star HD 169142, we present far-IR observations obtained with the PACS instrument onboard the Herschel Space Observatory. This work is part of the open time key program GASPS, which is aimed at studying the evolution of protoplanetary discs. To constrain the gas properties in the outer disc, we observed the star at several key gas-lines, including [OI] 63.2 and 145.5 μm, [CII] 157.7 μm, CO 72.8 and 90.2 μm, and o-H2O 78.7 and 179.5 μm. We only detect the [OI] 63.2 μm line in our spectra, and derive upper limits for the other lines. We complement our data set with PACS photometry and 12/13CO data obtained with the Submillimeter Array. Furthermore, we derive accurate stellar parameters from optical spectra and UV to mm photometry. We model the dust continuum with the 3D radiative transfer code MCFOST and use this model as an input to analyse the gas lines with the thermo-chemical code ProDiMo. Our dataset is consistent with a simple model in which the gas and dust are well-mixed in a disc with a continuous structure between 20 and 200 AU, but this is not a unique solution. Our modelling effort allows us to constrain the gas-to-dust mass ratio as well as the relative abundance of the PAHs in the disc by simultaneously fitting the lines of several species that originate in different regions. Our results are inconsistent with a gas-poor disc with a large UV excess; a gas mass of 5.0 ± 2.0 × 10-3 M⊙ is still present in this disc, in agreement with earlier CO observations. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.

  2. Distinguishing rhinitis and nasal neoplasia by radiography.

    PubMed

    Russo, M; Lamb, C R; Jakovljevic, S

    2000-01-01

    To compare the incidence of radiographic signs in dogs with rhinitis and primary nasal neoplasia and to assess the performance of observers for distinguishing these conditions, the nasal radiographs of 72 dogs with either rhinitis (n = 42) or primary nasal neoplasia (n = 30) were examined by two independent observers using custom-designed forms to record their interpretations. Rhinitis was associated with a higher incidence of focal or multifocal lesions, localised soft tissue opacities, lucent foci, and a lack of frontal sinus involvement. Neoplasia was associated with soft tissue opacities and loss of turbinate detail that affected the entire ipsilateral nasal cavity, signs of invasion of the bones surrounding the nasal cavity, and soft tissue/fluid opacities within the ipsilateral frontal sinus. The signs with the highest positive predictive value (PPV) for rhinitis were absence of frontal sinus lesions and lucent foci in nasal cavity (PPV of each 82%), and invasion of surrounding bones for neoplasia (PPV 88%). There were no significant differences in the position of the lesion within the nasal cavity, incidence of unilateral versus bilateral lesions, calcified lesions, or absence of teeth. There was moderate agreement between observers about the diagnosis (kappa 0.59). Areas (SE) under ROC curves were 0.94 (0.03) and 0.96 (0.03) for observers A and B, respectively (not significantly different; P = 0.68). These results indicate a high accuracy for radiologists examining dogs with nasal diseases. Differentiation of rhinitis and nasal neoplasia should be based on finding combinations of radiologic signs that together have a high PPV. Differences in interpretation between experienced observers in this study suggest that certain signs are potential sources of error.

  3. The role of disc self-gravity in circumbinary planet systems - I. Disc structure and evolution

    NASA Astrophysics Data System (ADS)

    Mutter, Matthew M.; Pierens, Arnaud; Nelson, Richard P.

    2017-03-01

    We present the results of two-dimensional hydrodynamic simulations of self-gravitating circumbinary discs around binaries whose parameters match those of the circumbinary planet-hosting systems Kepler-16, Kepler-34 and Kepler-35. Previous work has shown that non-self-gravitating discs in these systems form an eccentric precessing inner cavity due to tidal truncation by the binary, and planets which form at large radii migrate until stalling at this cavity. Whilst this scenario appears to provide a natural explanation for the observed orbital locations of the circumbinary planets, previous simulations have failed to match the observed planet orbital parameters. The aim of this work is to examine the role of self-gravity in modifying circumbinary disc structure as a function of disc mass, prior to considering the evolution of embedded circumbinary planets. In agreement with previous work, we find that for disc masses between one and five times the minimum mass solar nebula (MMSN), disc self-gravity affects modest changes in the structure and evolution of circumbinary discs. Increasing the disc mass to 10 or 20 MMSN leads to two dramatic changes in disc structure. First, the scale of the inner cavity shrinks substantially, bringing its outer edge closer to the binary. Secondly, in addition to the eccentric inner cavity, additional precessing eccentric ring-like features develop in the outer regions of the discs. If planet formation starts early in the disc lifetime, these changes will have a significant impact on the formation and evolution of planets and precursor material.

  4. Cervical intradural disc herniation.

    PubMed

    Iwamura, Y; Onari, K; Kondo, S; Inasaka, R; Horii, H

    2001-03-15

    A case report of anterior en bloc resected cervical intradural disc herniation and a review of the literature. To discuss the pathogenesis of cervical intradural disc herniation. Including this study case, only 17 cases of cervical intradural disc herniation have been reported. There have been few detailed reports concerning the pathogenesis of cervical intradural disc herniation. A cervical intradural disc herniation at C6-C7, with localized hypertrophy and segmentally ossified posterior longitudinal ligament, is reported in a 45-year-old man who had Brown-Sequard syndrome diagnosed on neurologic examination. Neuroradiologic, operative, and histologic findings, particularly the pathology of the anterior en bloc resected posterior vertebral portion of C6 and C7, were evaluated for discussion of the pathogenesis. Adhesion of dura mater and hypertrophic posterior longitudinal ligament was observed around a perforated portion of the herniated disc, and histologic study showed irregularity in fiber alignment accompanied by scattered inflammatory cell infiltration and hypertrophy in the posterior longitudinal ligament. The cervical intradural disc herniation was removed successfully and followed by C5-Th1 anterior interbody fusion with fibular strut graft. Neurologic recovery was complete except for minor residual sensory disturbance in the leg 7 years after the surgery. Cervical intradural disc herniation is an extremely rare condition. The pathogenesis remains obscure. Only 16 cases have been reported in the literature, and there has been little discussion concerning the local pathology of the herniated portion. The pathogenesis of the disease in the patient reported here was considered to be the adhesion and fragility of dura mater and posterior longitudinal ligament. This was caused by hypertrophy, with chronic inflammation and ossification of the posterior longitudinal ligament sustaining chronic mechanical irritation to the dura mater, leading to perforation of

  5. Combined use of Doppler OCT and en face OCT functions for discrimination of an aneurysm in the lamina cribrosa from a disc hemorrhage.

    PubMed

    Holló, Gábor

    2015-12-01

    In addition to retinal nerve fiber layer thickness measurements, the recently introduced AngioVue optical coherence tomography (OCT) offers corresponding layer-by-layer Doppler OCT and en face OCT functions, for simultaneous evaluation of perfusion and structure of the optic nerve head. We investigated the clinical usefulness of combined use of Doppler and en face Fourier-domain OCT functions of the AngioVue Fourier-domain OCT for discrimination of a disc hemorrhage and a disc hemorrhage-like atypical vessel structure located deep in the lamina cribrosa. We present our findings with AngioVue OCT on a disc hemorrhage and a spatially related retinal nerve fiber layer bundle defect in a glaucomatous eye (case 1). Both alterations were detected on en face OCT images without any Doppler OCT signal. We also report on an aneurysm suggestive for a disc hemorrhage on clinical examination and disc photography in a treated ocular hypertensive eye (case 2). The aneurysm was within the lamina cribrosa tissue at the border of the cup and the neuroretinal rim. This vascular structure produced strong Doppler signals but no structurally detectable signs on the en face OCT images. Combined evaluation of corresponding Doppler OCT and en face OCT images enables ophthalmologists to easily separate true disc hemorrhages from disc hemorrhage-like deep vascular structures. This is of clinical significance in preventing unnecessary intensification of pressure-lowering treatment in glaucoma.

  6. A simple framework for modelling the dependence of bulk Comptonization by turbulence on accretion disc parameters

    NASA Astrophysics Data System (ADS)

    Kaufman, J.; Blaes, O. M.; Hirose, S.

    2018-06-01

    Warm Comptonization models for the soft X-ray excess in active galactic nuclei (AGN) do not self-consistently explain the relationship between the Comptonizing medium and the underlying accretion disc. Because of this, they cannot directly connect the fitted Comptonization temperatures and optical depths to accretion disc parameters. Since bulk velocities exceed thermal velocities in highly radiation pressure dominated discs, in these systems bulk Comptonization by turbulence may provide a physical basis in the disc itself for warm Comptonization models. We model the dependence of bulk Comptonization on fundamental accretion disc parameters, such as mass, luminosity, radius, spin, inner boundary condition, and α. In addition to constraining warm Comptonization models, our model can help distinguish contributions from bulk Comptonization to the soft X-ray excess from those due to other physical mechanisms, such as absorption and reflection. By linking the time variability of bulk Comptonization to fluctuations in the disc vertical structure due to magnetorotational instability (MRI) turbulence, our results show that observations of the soft X-ray excess can be used to study disc turbulence in the radiation pressure dominated regime. Because our model connects bulk Comptonization to 1D vertical structure temperature profiles in a physically intuitive way, it will be useful for understanding this effect in future simulations run in new regimes.

  7. [Usage of polyvinylpyrrolidonic films for nasal cavity tamponade].

    PubMed

    Kriukov, A I; Karel'skaia, N A; Kleshnin, D A; Pashkin, I I

    2006-01-01

    The experience in otorhinolaryngological application of hydrogel films for nasal tamponade in nasal hemorrhage after surgical interventions on the intranasal structures and in nasal hemorrhage in leukemia patients was analysed.

  8. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  9. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  10. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  11. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  12. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  13. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  14. 21 CFR 868.5340 - Nasal oxygen cannula.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen cannula. 868.5340 Section 868.5340...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5340 Nasal oxygen cannula. (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through...

  15. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  16. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  17. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  18. An inner warp in the DoAr 44 T Tauri transition disc

    NASA Astrophysics Data System (ADS)

    Casassus, Simon; Avenhaus, Henning; Pérez, Sebastián; Navarro, Víctor; Cárcamo, Miguel; Marino, Sebastián; Cieza, Lucas; Quanz, Sascha P.; Alarcón, Felipe; Zurlo, Alice; Osses, Axel; Rannou, Fernando R.; Román, Pablo E.; Barraza, Marcelo

    2018-07-01

    Optical/IR images of transition discs (TDs) have revealed deep intensity decrements in the rings of HAeBes HD 142527 and HD 100453 that can be interpreted as shadowing from sharply tilted inner discs, such that the outer discs are directly exposed to stellar light. Here we report similar dips in SPHERE+IRDIS differential polarized imaging (DPI) of T Tauri DoAr 44. With a fairly axially symmetric ring in the sub-mm radio continuum, DoAr 44 is likely also a warped system. We constrain the warp geometry by comparing radiative transfer predictions with the DPI data in H band (Qϕ(H)) and with a re-processing of archival 336 GHz ALMA observations. The observed DPI shadows have coincident radio counterparts, but the intensity drops are much deeper in Qϕ(H) (˜88 per cent), compared to the shallow drops at 336 GHz (˜24 per cent). Radiative transfer predictions with an inner disc tilt of ˜30 ± 5 deg approximately account for the observations. ALMA long-baseline observations should allow the observation of the warped gas kinematics inside the cavity of DoAr 44.

  19. The lamppost model: effects of photon trapping, the bottom lamp and disc truncation

    NASA Astrophysics Data System (ADS)

    Niedźwiecki, Andrzej; Zdziarski, Andrzej A.

    2018-04-01

    We study the lamppost model, in which the primary X-ray sources in accreting black-hole systems are located symmetrically on the rotation axis on both sides of the black hole surrounded by an accretion disc. We show the importance of the emission of the source on the opposite side to the observer. Due to gravitational light bending, its emission can increase the direct (i.e., not re-emitted by the disc) flux by as much as an order of magnitude. This happens for near to face-on observers when the disc is even moderately truncated. For truncated discs, we also consider effects of emission of the top source gravitationally bent around the black hole. We also present results for the attenuation of the observed radiation with respect to that emitted by the lamppost as functions of the lamppost height, black-hole spin and the degree of disc truncation. This attenuation, which is due to the time dilation, gravitational redshift and the loss of photons crossing the black-hole horizon, can be as severe as by several orders of magnitude for low lamppost heights. We also consider the contribution to the observed flux due to re-emission by optically-thick matter within the innermost stable circular orbit.

  20. Typeability of DNA in Touch Traces Deposited on Paper and Optical Data Discs.

    PubMed

    Sołtyszewski, Ireneusz; Szeremeta, Michał; Skawrońska, Małgorzata; Niemcunowicz-Janica, Anna; Pepiński, Witold

    2015-01-01

    Nucleated epithelial cells that are transferred by casual touching and handling of objects are the primary source of biological evidence that is found in high-volume crimes. Cellular material associated with touch traces usually contains low levels of DNA template making it challenging to acquire an informative profile. The main purpose of this study was to examine the efficacy of DNA typing in fingerprints deposited on optical data discs and the office paper. Latent fingerprints were made by 60 subjects of both sexes (30 males and 30 females). A highly effective DNA extraction method with QIAamp DNA Mini Kit (Qiagen) and an increased sensitivity PCR by AmpFlSTR® NGM™ Amplification Kit (Applied Biosystems) carried out at standard 30 cycles and at increased 34 cycles were used. The mean value of total DNA recovery was 0.4 ng from CDs/DVDs and 0.3 ng from the office paper. Amplification of Low Template DNA (LT-DNA) resulted in improved analytical success by increasing the number of PCR cycles from standard 30 to 34. On the other hand, the increased PCR cycles resulted in allele drop-ins showing additional peaks, the majority of which were outside the stutter positions. Rigorous procedures and interpretation guidelines are required during LT-DNA for producing reliable and reproducible DNA profiles for forensic purposes.

  1. A review of nasal polyposis

    PubMed Central

    Newton, Jonathan Ray; Ah-See, Kim Wong

    2008-01-01

    Nasal polyps are common, affecting up to four percent of the population. Their etiology remains unclear, but they are known to have associations with allergy, asthma, infection, cystic fibrosis, and aspirin sensitivity. They present with nasal obstruction, anosmia, rhinorrhoea, post nasal drip, and less commonly facial pain. Clinical examination reveals single or multiple grey polypoid masses in the nasal cavity. Computerized tomography allows evaluation of the extent of the disease and is essential if surgical treatment is to be considered. Management of polyposis involves a combination of medical therapy and surgery. There is good evidence for the use of corticosteroids (systemic and topical) both as primary treatment and as postoperative prophylaxis against recurrence. Surgical treatment has been refined significantly over the past twenty years with the advent of endoscopic sinus surgery and, in general, is reserved for cases refractory to medical treatment. Recurrence of the polyposis is common with severe disease recurring in up to ten percent of patients. PMID:18728843

  2. Turbine disc sealing assembly

    DOEpatents

    Diakunchak, Ihor S.

    2013-03-05

    A disc seal assembly for use in a turbine engine. The disc seal assembly includes a plurality of outwardly extending sealing flange members that define a plurality of fluid pockets. The sealing flange members define a labyrinth flow path therebetween to limit leakage between a hot gas path and a disc cavity in the turbine engine.

  3. Normal and variant anatomy of the nasal tip.

    PubMed

    Ketcham, Amy S; Dobratz, Eric J

    2012-04-01

    A thorough understanding of nasal tip anatomy is a prerequisite to understanding the nuances of restructuring the nasal tip. The three-dimensional structural anatomy of the nasal tip is complex. Additionally, the interrelationship between these structures determines the ultimate form and function of the nasal tip. As a result, alteration of one structure in the tip will often lead to change in other portions of the nasal tip. This dynamic concept of anatomy in the nasal tip makes proper alteration of the nasal tip one of the most challenging tasks faced by a rhinoplasty surgeon. This article provides a fundamental knowledge of the normal anatomy of the tip structures and how their interaction with each other determines the shape and support of the lower portion of the nose. It also provides a description of some common variants of tip anatomy that cause patients to seek consultation for rhinoplasty. A proper understanding of the concepts presented provides a foundation to build on as the reader continues to explore the "nuances of the nasal tip." Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Proto-planetary disc evolution and dispersal

    NASA Astrophysics Data System (ADS)

    Rosotti, Giovanni Pietro

    2015-05-01

    Planets form from gas and dust discs in orbit around young stars. The timescale for planet formation is constrained by the lifetime of these discs. The properties of the formed planetary systems depend thus on the evolution and final dispersal of the discs, which is the main topic of this thesis. Observations reveal the existence of a class of discs called "transitional", which lack dust in their inner regions. They are thought to be the last stage before the complete disc dispersal, and hence they may provide the key to understanding the mechanisms behind disc evolution. X-ray photoevaporation and planet formation have been studied as possible physical mechanisms responsible for the final dispersal of discs. However up to now, these two phenomena have been studied separately, neglecting any possible feedback or interaction. In this thesis we have investigated what is the interplay between these two processes. We show that the presence of a giant planet in a photo-evaporating disc can significantly shorten its lifetime, by cutting the inner regions from the mass reservoir in the exterior of the disc. This mechanism produces transition discs that for a given mass accretion rate have larger holes than in models considering only X-ray photo-evaporation, constituting a possible route to the formation of accreting transition discs with large holes. These discs are found in observations and still constitute a puzzle for the theory. Inclusion of the phenomenon called "thermal sweeping", a violent instability that can destroy a whole disc in as little as 10 4 years, shows that the outer disc left can be very short-lived (depending on the X-ray luminosity of the star), possibly explaining why very few non accreting transition discs are observed. However the mechanism does not seem to be efficient enough to reconcile with observations. In this thesis we also show that X-ray photo-evaporation naturally explains the observed correlation between stellar masses and accretion

  5. The transiting dust clumps in the evolved disc of the Sun-like UXor RZ Psc

    PubMed Central

    Kenworthy, Matthew A.; Pepper, Joshua; Rodriguez, Joseph E.; Siverd, Robert J.; Stassun, Keivan G.; Wyatt, Mark C.

    2017-01-01

    RZ Psc is a young Sun-like star, long associated with the UXor class of variable stars, which is partially or wholly dimmed by dust clumps several times each year. The system has a bright and variable infrared excess, which has been interpreted as evidence that the dimming events are the passage of asteroidal fragments in front of the host star. Here, we present a decade of optical photometry of RZ Psc and take a critical look at the asteroid belt interpretation. We show that the distribution of light curve gradients is non-uniform for deep events, which we interpret as possible evidence for an asteroidal fragment-like clump structure. However, the clumps are very likely seen above a high optical depth midplane, so the disc’s bulk clumpiness is not revealed. While circumstantial evidence suggests an asteroid belt is more plausible than a gas-rich transition disc, the evolutionary status remains uncertain. We suggest that the rarity of Sun-like stars showing disc-related variability may arise because (i) any accretion streams are transparent and/or (ii) turbulence above the inner rim is normally shadowed by a flared outer disc. PMID:28280566

  6. Prevalence and risk factors for Staphylococcus aureus and methicillin-resistant Staphylococcus aureus nasal carriage inpatients in a tertiary care hospital's chest clinic in Turkey.

    PubMed

    Oguzkaya-Artan, M; Artan, C; Baykan, Z

    2016-01-01

    We aimed to determine the prevalence and associated risk factors for nasal methicillin-sensitive and methicillin-resistant Staphylococcus aureus (MSSA/MRSA) carriage among patients admitted to a chest clinic of a tertiary care hospital in this study. Nasal samples were taken from anterior nares were cultured in CHROMagar S. aureus plates, MRSA was determined by disc diffusion method (cefoxitin 30 μg) according to the Clinical and Laboratory Standards Institute guidelines and CHROMagar MRSA plates. A questionnaire was applied to determine the demographic characteristics of the participants and risk factors for carriage. Fisher's exact test, univariate and multivariate logistic regression analysis were used. A P < 0.05 indicated a statistically significant difference. This is a cross-sectional study covering all the patients (n = 431) admitted to Kayseri Training and Research Hospital's Chest Clinic from January 1st to 31st 2014. Of all these patients 55 (12.8%) were nasal S. aureus carriers. MRSA positivity was in five among these patients. In multivariate analysis, being under 65 years of age (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.0-3.3), and having prosthesis (OR, 4.8; 95% CI, 1.6-13.9) were found as risk factors for MSSA colonization. The prevalence of nasal carriage of MSSA was low in our study population. The only risk factors playing role in carriage were found as being under the age of 65 and having prosthesis.

  7. Normative Nasalance Scores for Brazilian Portuguese Using New Speech Stimuli.

    PubMed

    Marino, Viviane Cristina de Castro; Dutka, Jeniffer de Cássia Rillo; de Boer, Gillian; Cardoso, Vanessa Moraes; Ramos, Renata Giorgetto; Bressmann, Tim

    2015-01-01

    Normative data were established for newly developed speech materials for nasalance assessment in Brazilian Portuguese. Nasalance scores of preexisting passages (oral ZOO-BR, low-pressure oral ZOO-BR2 and NASAL-BR), new nasalance passages (oral Dudu no zoológico, oral Dudu no bosque, oral-nasal O cãozinho Totó and nasal O nenê) and Brasilcleft articulation screening sentences were collected from 245 speakers of Brazilian Portuguese, including 121 males and 124 females, divided into 4 groups: children (5-9 years), adolescents (10-19 years), young adults (20-24 years) and adults (25-35 years). Across all nasalance passages, adult females scored on average 2 percentage points higher than males. Children scored 2-4 percentage points lower than older groups for the preexisting nasalance passages ZOO-BR and ZOO-BR2. Nasalance scores for the new nasalance passages were not significantly different from the preexisting passages. Scores for high-pressure sentences did not differ significantly from the oral nasalance passage Dudu no bosque. The nasalance scores for the new nasalance passages were equivalent to the preexisting materials. The new shortened and simplified nasalance passages will be useful for assessing young children. Normative scores for the Brasilcleft high-pressure sentences were equivalent to the new oral passage Dudu no bosque. © 2016 S. Karger AG, Basel.

  8. Nasal patency and otorhinolaryngologic-orofacial features in children.

    PubMed

    Milanesi, Jovana de Moura; Berwig, Luana Cristina; Schuch, Luiz Henrique; Ritzel, Rodrigo Agne; Silva, Ana Maria Toniolo da; Corrêa, Eliane Castilhos Rodrigues

    2017-11-21

    Nasal obstruction is a common symptom in childhood, related to rhinitis and pharyngeal tonsil hypertrophy. In the presence of nasal obstruction, nasal patency may be reduced, and nasal breathing is replaced by mouth breathing. Orofacial and otorhinolaryngologic changes are related to this breathing mode. Objective evaluation of upper airways may be obtained through nasal patency measurement. To compare nasal patency and otorhinolaryngologic-orofacial features in children. One hundred and twenty three children, 6-12 year-old, and of both sexes underwent speech therapy evaluation, according to Orofacial Myofunctional Evaluation protocol, clinical and endoscopic otorhinolaryngologic examination and nasal patency measurement, using the absolute and predicted (%) peak nasal inspiratory flow values. Lower values of absolute and estimated peak nasal inspiratory flow values were found in children with restless sleep (p=0.006 and p=0.002), nasal obstruction report (p=0.027 and p=0.023), runny nose (p=0.004 and p=0.012), unsystematic lip closure during mastication (p=0.040 and p=0.026), masticatory speed reduced (p=0.006 and p=0.008) and altered solid food swallowing (p=0.006 and p=0.001). Absolute peak nasal inspiratory flow was lower in children with pale inferior turbinate (p=0.040), reduced hard palate width (p=0.037) and altered speech (p=0.004). Higher absolute values were found in children with increased tongue width (p=0.027) and, higher absolute and predicted (%) in children with mild everted lip (p=0.008 and p=0.000). Nasal patency was lower in children with restless sleep, rhinitis signs and symptoms, hard palate width reduced and with changes in mastication, deglutition and speech functions. It is also emphasized that most of the children presented signs and symptom of allergic rhinitis. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Acoustic Analysis of Nasal Vowels in Monguor Language

    NASA Astrophysics Data System (ADS)

    Zhang, Hanbin

    2017-09-01

    The purpose of the study is to analyze the spectrum characteristics and acoustic features for the nasal vowels [ɑ˜] and [ɔ˜] in Monguor language. On the base of acoustic parameter database of the Monguor speech, the study finds out that there are five main zero-pole pairs appearing for the nasal vowel [ɔ˜] and two zero-pole pairs appear for the nasal vowel [ɔ˜]. The results of regression analysis demonstrate that the duration of the nasal vowel [ɔ˜] or the nasal vowel [ɔ˜] can be predicted by its F1, F2 and F3 respectively.

  10. Optical Coherence Tomography in Glaucoma

    NASA Astrophysics Data System (ADS)

    Berisha, Fatmire; Hoffmann, Esther M.; Pfeiffer, Norbert

    Retinal nerve fiber layer (RNFL) thinning and optic nerve head cupping are key diagnostic features of glaucomatous optic neuropathy. The higher resolution of the recently introduced SD-OCT offers enhanced visualization and improved segmentation of the retinal layers, providing a higher accuracy in identification of subtle changes of the optic disc and RNFL thinning associated with glaucoma.

  11. Optic nerve involvement in a borderline lepromatous leprosy patient on multidrug therapy.

    PubMed

    Prabha, Neel; Mahajan, Vikram K; Sharma, Surinder K; Sharma, Vikas; Chauhan, Pushpinder S; Mehta, Karaninder S; Abhinav, C; Khatri, Gaytri; Chander, Bal; Tuli, Rajiv

    2013-12-01

    Amidst the plethora of ocular complications of leprosy, involvement of the posterior segment or optic nerve is extremely rare. The mechanism of optic neuritis in leprosy is poorly understood. A 47 year-old man presented with a single lesion suggestive of mid-borderline (BB) leprosy over left periorbital region; the histology showed borderline lepromatous (BL) leprosy with a BI of 3+. After initial improvement with WHO MDT-MB and prednisolone (40 mg/d) he developed sudden and painless diminished vision in the left eye, about 3 weeks later. His visual acuity was 6/9 in the left and 6/6 in the right eye, and there was left optic disc edema, hyperemia and blurred disc margins. Treatment with prednisolone (60 mg/d) along with WHO MDT-MB continued. A month later he returned with painless diminished vision in the other eye as well. Visual acuity was 6/6 in the right and 6/12 in the left eye, and there was right optic disc edema and left optic disc atrophy. CT of the head and MRI of the brain were normal. Inflammatory edema of the orbital connective tissue or other surrounding structures, or direct infiltration of vasa nervosa with resultant vascular occlusion leading to optic nerve ischemia, seems the most plausible explanation of optic nerve involvement in this case.

  12. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

    PubMed

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S

    2016-09-15

    Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  13. Age-related change and sex difference over 60s in disc-fovea angle in Japanese population: the Nagahama Study.

    PubMed

    Miyata, Manabu; Yoshikawa, Munemitsu; Ohtsuki, Hiroshi; Muraoka, Yuki; Hata, Masayuki; Yokota, Satoshi; Fujimoto, Masahiro; Miyake, Masahiro; Tabara, Yasuharu; Matsuda, Fumihiko; Yoshimura, Nagahisa

    2018-01-25

    To analyse the disc-fovea angle (DFA) by age group and to compare sex differences in each age group in a large cohort population. This community-based cross-sectional cohort study included 9682 eyes of 9682 volunteers (aged 30-75 years). We measured the DFA, which is the angle between a horizontal line and a line connecting the fovea with the centroid of an optic disc on fundus photographs of the right eye. We manually marked the fovea and surrounded the optic disc. The centroid of an optic disc and the DFA was automatically calculated using originally developed software. We compared the DFA between age groups in 10-year increments and investigated sex differences of DFA in each age group. Overall mean DFA was 6.32 ± 3.53°. The DFA of older subjects was significantly larger than that of younger subjects (p < 0.001). The DFA of women was larger than that of men in their 60s and 70s (p < 0.001 for both), but not in subjects in their 30s, 40s and 50s. Larger DFA in women than in men in their 60s and 70s suggests the possibility that age-related excyclo-shift occurs more easily in postmenopausal women compared to men of the same age. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Enclosed rotary disc air pulser

    DOEpatents

    Olson, A. L.; Batcheller, Tom A.; Rindfleisch, J. A.; Morgan, John M.

    1989-01-01

    An enclosed rotary disc air pulser for use with a solvent extraction pulse olumn includes a housing having inlet, exhaust and pulse leg ports, a shaft mounted in the housing and adapted for axial rotation therein, first and second disc members secured to the shaft within the housing in spaced relation to each other to define a chamber therebetween, the chamber being in communication with the pulse leg port, the first disc member located adjacent the inlet port, the second disc member being located adjacent the exhaust port, each disc member having a milled out portion, the disc members positioned on the shaft so that as the shaft rotates, the milled out portions permit alternative cyclical communication between the inlet port and the chamber and the exhaust port and the chamber.

  15. Does Optic Nerve Head Size Variation Affect Circumpapillary Retinal Nerve Fiber Layer Thickness Measurement by Optical Coherence Tomography?

    PubMed Central

    Huang, David; Chopra, Vikas; Lu, Ake Tzu-Hui; Tan, Ou; Francis, Brian; Varma, Rohit

    2012-01-01

    Purpose. To determine the relationship between retinal nerve fiber layer (RNFL) thickness, optic disc size, and image magnification. Methods. The cohort consisted of 196 normal eyes of 101 participants in the Advanced Imaging for Glaucoma Study (AIGS), a multicenter, prospective, longitudinal study to develop advanced imaging technologies for glaucoma diagnosis. Scanning laser tomography was used to measure disc size. Optical coherence tomography (OCT) was used to perform circumpapillary RNFL thickness measurements using the standard fixed 3.46-mm nominal scan diameter. A theoretical model of magnification effects was developed to relate RNFL thickness (overall average) with axial length and magnification. Results. Multivariate regression showed no significant correlation between RNFL thickness and optic disc area (95% confidence interval [CI] = −0.9 to 4.1 μm/mm2, P = 0.21). Linear regression showed that RNFL thickness depended significantly on axial length (slope = −3.1 μm/mm, 95% CI = −4.9 to −1.3, P = 0.001) and age (slope = −0.3 μm/y, 95% CI = −0.5 to −0.2, P = 0.0002). The slope values agreed closely with the values predicted by the magnification model. Conclusions. There is no significant association between RNFL thickness and optic disc area. Previous publications that showed such an association may have been biased by the effect of axial length on fundus image magnification and, therefore, both measured RNFL thickness and apparent disc area. The true diameter of the circumpapillary OCT scan is larger for a longer eye (more myopic eye), leading to a thinner RNFL measurement. Adjustment of measured RNFL thickness by axial length, in addition to age, may lead to a tighter normative range and improve the detection of RNFL thinning due to glaucoma. PMID:22743319

  16. Nasal Base Retraction: A Treatment Algorithm.

    PubMed

    Tas, Süleyman; Colakoglu, Salih; Lee, Bernard Travis

    2017-06-01

    Nasal base retraction results from cephalic malposition of the alar base in the vertical plane, which causes disharmony of the alar base with the rest of the nose structures. Correcting nasal base retraction is very important for improved aesthetic outcomes; however, there is a limited body of literature about this deformity and its treatment. Create a nasal base retraction treatment algorithm based on a severity classification system. This is a retrospective case review study of 53 patients who underwent rhinoplasty with correction of alar base retraction by the senior author (S.T.). The minimum follow-up time was 6 months. Levator labii alaque nasi muscle dissection or alar base release with or without a rim graft on the effected side were performed based on the severity of the alar base retraction. Aesthetic results were assessed with objective grading of preoperative and postoperative patient photographs by two independent plastic surgeons. Functional improvement was assessed with patient self-evaluations of nasal patency. Also, a rhinoplasty outcomes evaluation (ROE) questionnaire was distributed to patients. Comparison of preoperative and postoperative photographs demonstrated that nasal base asymmetry was significantly improved in all cases, and 85% of the patients had complete symmetry. Nasal obstruction was also significantly reduced after surgery (P < 0.001). The majority of patients reported satisfaction (92.5%), with an ROE total score greater than or equal to 20. New techniques and a treatment algorithm for correcting nasal base retraction deformities that will help rhinoplasty surgeons obtain aesthetically and functionally pleasing outcomes for patients. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  17. Immunolocalization of Delta-Giardin within the Ventral Disc in of Trophozoites and in cysts of Giardia duodenalis using the Multiplex Laser Scanning Confocal Microscopy

    USDA-ARS?s Scientific Manuscript database

    Immunolocalization of alpha2-, beta- and delta-giardin in Giardia showed that in the trophozoites and cysts delta-giardin it strictly associated with the ventral disc. Optical sectioning of the ventral discs, together with quantitative colocalization of the immunoreactivity for delta- and beta-giard...

  18. Effects of nasal drug delivery device and its orientation on sprayed particle deposition in a realistic human nasal cavity.

    PubMed

    Tong, Xuwen; Dong, Jingliang; Shang, Yidan; Inthavong, Kiao; Tu, Jiyuan

    2016-10-01

    In this study, the effects of nasal drug delivery device and the spray nozzle orientation on sprayed droplets deposition in a realistic human nasal cavity were numerically studied. Prior to performing the numerical investigation, an in-house designed automated actuation system representing mean adults actuation force was developed to produce realistic spray plume. Then, the spray plume development was filmed by high speed photography system, and spray characteristics such as spray cone angle, break-up length, and average droplet velocity were obtained through off-line image analysis. Continuing studies utilizing those experimental data as boundary conditions were applied in the following numerical spray simulations using a commercially available nasal spray device, which was inserted into a realistic adult nasal passage with external facial features. Through varying the particle releasing direction, the deposition fractions of selected particle sizes on the main nasal passage for targeted drug delivery were compared. The results demonstrated that the middle spray direction showed superior spray efficiency compared with upper or lower directions, and the 10µm agents were the most suitable particle size as the majority of sprayed agents can be delivered to the targeted area, the main passage. This study elaborates a comprehensive approach to better understand nasal spray mechanism and evaluate its performance for existing nasal delivery practices. Results of this study can assist the pharmaceutical industry to improve the current design of nasal drug delivery device and ultimately benefit more patients through optimized medications delivery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Erbium:YAG laser contouring of the nasal dorsum: a preliminary investigation

    NASA Astrophysics Data System (ADS)

    Truong, Mai T.; Majaron, Boris; Pandoh, Nidhi S.; Wong, Brian J.

    2001-05-01

    In conventional aesthetic rhinoplasty operations, manual or powered rasps are used to reduce the osseo-cartilagenous nasal dorsum. This tactile method requires palpation of the instrument and the dorsum during surgery to estimate the degree of volume reduction, and often requires forceful manipulation of the dorsum which may illicit pain during surgery and contribute to post-operative edema and echymosis. In this preliminary study, we investigated the use of the Erbium:YAG laser ((lambda) equals294 micrometers ) to reduce bone and cartilage using ex-vivo porcine nasal dorsum and human cadaveric tissues. The short pulsed length and high absorption of this laser in biologic tissues results in minimization of thermal injury which are ideal for non- contact optical contouring of osseous and cartilagenous tissues in the face. Two Erbium:YAG lasers were used to ablate fresh porcine nasal bone and compared for their use. One Erbium:YAG laser, the Fidelis Laser, Fontana Medical Lasers, Ljubljana, Slovenija with variable pulse repetition rates (2 to 50 Hz), pulse energy (80 to 1000 mJ), and pulse duration (100, 300, 750 and 1000 microsecond(s) ) was used and compared to the Ultrafine Erbium:YAG laser, Coherent Inc., Santa Clara California, with variable pulse repetition rate (2 to 10 Hz), pulse energy (2-16 J/cm2), and spot diameter (2-6 mm). Only laser parameters approximating the conditions for thermal confinement were evaluated.

  20. Review of ultra-high density optical storage technologies for big data center

    NASA Astrophysics Data System (ADS)

    Hao, Ruan; Liu, Jie

    2016-10-01

    In big data center, optical storage technologies have many advantages, such as energy saving and long lifetime. However, how to improve the storage density of optical storage is still a huge challenge. Maybe the multilayer optical storage technology is the good candidate for big data center in the years to come. Due to the number of layers is primarily limited by transmission of each layer, the largest capacities of the multilayer disc are around 1 TB/disc and 10 TB/ cartridge. Holographic data storage (HDS) is a volumetric approach, but its storage capacity is also strictly limited by the diffractive nature of light. For a holographic disc with total thickness of 1.5mm, its potential capacities are not more than 4TB/disc and 40TB/ cartridge. In recent years, the development of super resolution optical storage technology has attracted more attentions. Super-resolution photoinduction-inhibition nanolithography (SPIN) technology with 9 nm feature size and 52nm two-line resolution was reported 3 years ago. However, turning this exciting principle into a real storage system is a huge challenge. It can be expected that in the future, the capacities of 10TB/disc and 100TB/cartridge can be achieved. More importantly, due to breaking the diffraction limit of light, SPIN technology will open the door to improve the optical storage capacity steadily to meet the need of the developing big data center.

  1. Optic nerve head cupping in glaucomatous and non-glaucomatous optic neuropathy.

    PubMed

    Fard, Masoud Aghsaei; Moghimi, Sasan; Sahraian, Alireza; Ritch, Robert

    2018-05-23

    Enlargement of optic disc cupping is seen both in glaucoma and in neurological disorders. We used enhanced depth imaging with spectral-domain optical coherence tomography to differentiate glaucoma from non-glaucomatous optic neuropathy. The optic discs were scanned in this prospective comparative study, and the lamina cribrosa (LC) thickness and anterior laminar depth (ALD) in the central, superior and inferior optic nerve head, and peripapillary choroidal thicknesses, were measured. There were 31 eyes of 31 patients with severe glaucoma and 33 eyes of 19 patients with non-glaucomatous cupping. Eyes of 29 healthy controls were also enrolled. There was no significant difference in the cup-to-disc ratio and in the average peripapillary nerve fibre layer thickness between the glaucoma and non-glaucomatous cupping groups (p>0.99). The average peripapillary choroidal thickness was thinner in glaucoma eyes than in the control eyes after adjusting for age and axial length. Glaucomatous and non-glaucomatous eyes had greater ALD and thinner LC than the control eyes (p<0.001 for both). ALDs of glaucoma eyes were deeper than non-glaucomatous eyes (p=0.01 for central ALD) when age, axial length and peripapillary choroidal thickness were included in the linear mixed model. Prelaminar thickness and LC thickness of glaucoma eyes were not different from non-glaucomatous eyes after adjusting. Deeper ALD was observed in glaucoma than non-glaucomatous cupping after adjusting for choroidal thickness. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Characteristics of peripapillary retinal nerve fiber layer in preterm children.

    PubMed

    Wang, Jingyun; Spencer, Rand; Leffler, Joel N; Birch, Eileen E

    2012-05-01

    To examine quantitatively characteristics of the peripapillary retinal nerve fiber layer (RNFL) in preterm children using Fourier-domain optical coherence tomography (FD-OCT). Prospective cross-sectional study. A 3-mm high-resolution FD-OCT peripapillary RNFL circular scan centered on the optic disc was obtained from right eyes of 25 preterm children (10.6 ± 3.7 years old, 8 preterm and 17 with regressed retinopathy of prematurity with normal-appearing posterior poles) and 54 full-term controls (9.8 ± 3.2 years old). Images were analyzed using Spectralis FD-OCT software to obtain average thickness measurements for 6 sectors (temporal superior, temporal, temporal inferior, nasal inferior, nasal, nasal superior), and the global average. The RNFL global average for preterm children was 8% thinner than for full-term controls. In the preterm group, peripapillary RNFL thickness on the temporal side of the disc was 6% thicker than in full-term controls, while all other peripapillary RNFL sectors were 9% to 13% thinner. In the preterm group, temporal sector peripapillary RNFL thickness was correlated with gestational age (r = -0.47, P < .001), with foveal center total thickness (r = 0.48, P = .008, 1-tailed), and with visual acuity (r = 0.42; P = .026, 1-tailed). The significantly thinner RNFL global average for preterm children suggests that prematurity is associated with subclinical optic nerve hypoplasia. Significant correlations between temporal sector RNFL thickness and both the foveal thickness and visual acuity suggest that the peripapillary RNFL is related to abnormalities in macular development as a result of preterm birth. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Simultaneous macula detection and optic disc boundary segmentation in retinal fundus images

    NASA Astrophysics Data System (ADS)

    Girard, Fantin; Kavalec, Conrad; Grenier, Sébastien; Ben Tahar, Houssem; Cheriet, Farida

    2016-03-01

    The optic disc (OD) and the macula are important structures in automatic diagnosis of most retinal diseases inducing vision defects such as glaucoma, diabetic or hypertensive retinopathy and age-related macular degeneration. We propose a new method to detect simultaneously the macula and the OD boundary. First, the color fundus images are processed to compute several maps highlighting the different anatomical structures such as vessels, the macula and the OD. Then, macula candidates and OD candidates are found simultaneously and independently using seed detectors identified on the corresponding maps. After selecting a set of macula/OD pairs, the top candidates are sent to the OD segmentation method. The segmentation method is based on local K-means applied to color coordinates in polar space followed by a polynomial fitting regularization step. Pair scores are updated, resulting in the final best macula/OD pair. The method was evaluated on two public image databases: ONHSD and MESSIDOR. The results show an overlapping area of 0.84 on ONHSD and 0.90 on MESSIDOR, which is better than recent state of the art methods. Our segmentation method is robust to contrast and illumination problems and outputs the exact boundary of the OD, not just a circular or elliptical model. The macula detection has an accuracy of 94%, which again outperforms other macula detection methods. This shows that combining the OD and macula detections improves the overall accuracy. The computation time for the whole process is 6.4 seconds, which is faster than other methods in the literature.

  4. Metallicity of solar-type stars with debris discs and planets⋆

    NASA Astrophysics Data System (ADS)

    Maldonado, J.; Eiroa, C.; Villaver, E.; Montesinos, B.; Mora, A.

    2012-05-01

    planet eccentricity. Conclusions: Our data show that the presence of planets, not the debris disc, correlates with the stellar metallicity. The results confirm that core-accretion models represent suitable scenarios for debris disc and planet formation. These conclusions are based on a number of stars with discs and planets considerably larger than in previous works, in particular stars hosting low-mass planets and debris discs. Dynamical instabilities produced by eccentric giant planets could explain the suggested dust luminosity trends observed for stars with debris discs and planets. Based on observations collected at the Centro Astronómico Hispano Alemán (CAHA) at Calar Alto, operated jointly by the Max-Planck Institut für Astronomie and the Instituto de Astrofísica de Andalucía (CSIC); observations made with the Italian Telescopio Nazionale Galileo (TNG) operated on the island of La Palma by the Fundación Galileo Galilei of the INAF (Istituto Nazionale di Astrofisica); observations made with the Nordic Optical Telescope, operated on the island of La Palma jointly by Denmark, Finland, Iceland, Norway, and Sweden, in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofisica de Canarias; and data obtained from the ESO Science Archive Facility.Full Tables 1 and 5 are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/541/A40

  5. Polar alignment of a protoplanetary disc around an eccentric binary II: Effect of binary and disc parameters

    NASA Astrophysics Data System (ADS)

    Martin, Rebecca G.; Lubow, Stephen H.

    2018-06-01

    In a recent paper Martin & Lubow showed that a circumbinary disc around an eccentric binary can undergo damped nodal oscillations that lead to the polar (perpendicular) alignment of the disc relative to the binary orbit. The disc angular momentum vector aligns to the eccentricity vector of the binary. We explore the robustness of this mechanism for a low mass disc (0.001 of the binary mass) and its dependence on system parameters by means of hydrodynamic disc simulations. We describe how the evolution depends upon the disc viscosity, temperature, size, binary mass ratio, orbital eccentricity and inclination. We compare results with predictions of linear theory. We show that polar alignment of a low mass disc may occur over a wide range of binary-disc parameters. We discuss the application of our results to the formation of planetary systems around eccentric binary stars.

  6. Testing the molecular-hydrogen Kennicutt-Schmidt law in the low-density environments of extended ultraviolet disc galaxies

    NASA Astrophysics Data System (ADS)

    Watson, Linda C.; Martini, Paul; Lisenfeld, Ute; Böker, Torsten; Schinnerer, Eva

    2016-01-01

    Studying star formation beyond the optical radius of galaxies allows us to test empirical relations in extreme conditions with low average gas density and low molecular fraction. Previous studies discovered galaxies with extended ultraviolet (XUV) discs, which often contain star-forming regions with lower Hα-to-far-UV (FUV) flux ratios compared to inner disc star-forming regions. However, most previous studies lack measurements of molecular gas, which is presumably the component of the interstellar medium out of which stars form. We analysed published CO measurements and upper limits for 15 star-forming regions in the XUV or outer disc of three nearby spiral galaxies and a new CO upper limit from the IRAM (Institut de Radioastronomie Millimétrique) 30 m telescope in one star-forming region at r = 3.4r25 in the XUV disc of NGC 4625. We found that the star-forming regions are in general consistent with the same molecular-hydrogen Kennicutt-Schmidt law that applies within the optical radius, independent of whether we used Hα or FUV as the star formation rate (SFR) tracer. However, a number of the CO detections are significantly offset towards higher SFR surface density for their molecular-hydrogen surface density. Deeper CO data may enable us to use the presence or absence of molecular gas as an evolutionary probe to break the degeneracy between age and stochastic sampling of the initial mass function as the explanation for the low Hα-to-FUV flux ratios in XUV discs.

  7. Diagnostic strategies in nasal congestion

    PubMed Central

    Krouse, John; Lund, Valerie; Fokkens, Wytske; Meltzer, Eli O

    2010-01-01

    Nasal congestion is a major symptom of upper respiratory tract disorders, and its characterization an important part of the diagnosis of these illnesses. Patient history and assessment of nasal symptoms are essential components of diagnosis, providing an initial evaluation that may be adequate to rule out serious conditions. However, current congestion medications are not always fully effective. Thus, if symptoms do not respond adequately to therapy, or symptoms suggestive of more serious conditions are present, specialized assessments may be needed. Various techniques are available for diagnosing patients, including those used chiefly by primary care clinicians and those requiring the expertise of otolaryngologists, allergists, and other specialists. Endoscopy remains a mainstay for evaluating nasal blockage and its causes, while modalities such as peak nasal inspiratory flow and acoustic rhinometry are evolving to provide easy-to-use, noninvasive procedures that are sensitive enough to measure small but clinically important abnormalities and therapeutic changes. Several imaging modalities are available to the specialist for severe or unusual cases, as are specialized diagnostic procedures that measure adjunctive features of congestion, such as impaired mucociliary function. PMID:20463824

  8. Eccentricity evolution during planet-disc interaction

    NASA Astrophysics Data System (ADS)

    Ragusa, Enrico; Rosotti, Giovanni; Teyssandier, Jean; Booth, Richard; Clarke, Cathie J.; Lodato, Giuseppe

    2018-03-01

    During the process of planet formation, the planet-disc interactions might excite (or damp) the orbital eccentricity of the planet. In this paper, we present two long (t ˜ 3 × 105 orbits) numerical simulations: (a) one (with a relatively light disc, Md/Mp = 0.2), where the eccentricity initially stalls before growing at later times and (b) one (with a more massive disc, Md/Mp = 0.65) with fast growth and a late decrease of the eccentricity. We recover the well-known result that a more massive disc promotes a faster initial growth of the planet eccentricity. However, at late times the planet eccentricity decreases in the massive disc case, but increases in the light disc case. Both simulations show periodic eccentricity oscillations superimposed on a growing/decreasing trend and a rapid transition between fast and slow pericentre precession. The peculiar and contrasting evolution of the eccentricity of both planet and disc in the two simulations can be understood by invoking a simple toy model where the disc is treated as a second point-like gravitating body, subject to secular planet-planet interaction and eccentricity pumping/damping provided by the disc. We show how the counterintuitive result that the more massive simulation produces a lower planet eccentricity at late times can be understood in terms of the different ratios of the disc-to-planet angular momentum in the two simulations. In our interpretation, at late times the planet eccentricity can increase more in low-mass discs rather than in high-mass discs, contrary to previous claims in the literature.

  9. Finite Element Model and Validation of Nasal Tip Deformation

    PubMed Central

    Manuel, Cyrus T; Harb, Rani; Badran, Alan; Ho, David; Wong, Brian JF

    2016-01-01

    Nasal tip mechanical stability is important for functional and cosmetic nasal airway surgery. Palpation of the nasal tip provides information on tip strength to the surgeon, though it is a purely subjective assessment. Providing a means to simulate nasal tip deformation with a validated model can offer a more objective approach in understanding the mechanics and nuances of the nasal tip support and eventual nasal mechanics as a whole. Herein we present validation of a finite element (FE) model of the nose using physical measurements recorded using an ABS plastic-silicone nasal phantom. Three-dimensional photogrammetry was used to capture the geometry of the phantom at rest and while under steady state load. The silicone used to make the phantom was mechanically tested and characterized using a linear elastic constitutive model. Surface point clouds of the silicone and FE model were compared for both the loaded and unloaded state. The average Hausdorff distance between actual measurements and FE simulations across the nose were 0.39mm ± 1.04 mm and deviated up to 2mm at the outermost boundaries of the model. FE simulation and measurements were in near complete agreement in the immediate vicinity of the nasal tip with millimeter accuracy. We have demonstrated validation of a two-component nasal FE model, which could be used to model more complex modes of deformation where direct measurement may be challenging. This is the first step in developing a nasal model to simulate nasal mechanics and ultimately the interaction between geometry and airflow. PMID:27633018

  10. Finite Element Model and Validation of Nasal Tip Deformation.

    PubMed

    Manuel, Cyrus T; Harb, Rani; Badran, Alan; Ho, David; Wong, Brian J F

    2017-03-01

    Nasal tip mechanical stability is important for functional and cosmetic nasal airway surgery. Palpation of the nasal tip provides information on tip strength to the surgeon, though it is a purely subjective assessment. Providing a means to simulate nasal tip deformation with a validated model can offer a more objective approach in understanding the mechanics and nuances of the nasal tip support and eventual nasal mechanics as a whole. Herein we present validation of a finite element (FE) model of the nose using physical measurements recorded using an ABS plastic-silicone nasal phantom. Three-dimensional photogrammetry was used to capture the geometry of the phantom at rest and while under steady state load. The silicone used to make the phantom was mechanically tested and characterized using a linear elastic constitutive model. Surface point clouds of the silicone and FE model were compared for both the loaded and unloaded state. The average Hausdorff distance between actual measurements and FE simulations across the nose were 0.39 ± 1.04 mm and deviated up to 2 mm at the outermost boundaries of the model. FE simulation and measurements were in near complete agreement in the immediate vicinity of the nasal tip with millimeter accuracy. We have demonstrated validation of a two-component nasal FE model, which could be used to model more complex modes of deformation where direct measurement may be challenging. This is the first step in developing a nasal model to simulate nasal mechanics and ultimately the interaction between geometry and airflow.

  11. Nasal Myiasis in Hinduism and Contemporary Otorhinolaryngology.

    PubMed

    Bosmia, Anand N; Zimmermann, Terence M; Griessenauer, Christoph J; Shane Tubbs, R; Rosenthal, Eben L

    2017-08-01

    Various case reports on nasal myiasis written during the 1990s and 2000s state that nasal myiasis, which is known as peenash among South Asian natives, is a form of divine punishment in Hindu mythology, but do not provide citations from Hindu scriptures that would suggest this interpretation. This paper aims to discuss the phenomenon of peenash in a historical context by examining medical literature written during the nineteenth and early twentieth centuries, to identify Hindu texts contributing to the belief of some Hindus that nasal myiasis is a form of divine punishment, and to provide an overview of contemporary treatment for and management of nasal myiasis.

  12. Bulk Comptonization by Turbulence in Black Hole Accretion Discs

    NASA Astrophysics Data System (ADS)

    Kaufman, Jason

    Radiation pressure dominated accretion discs may have turbulent velocities that exceed the electron thermal velocities. Bulk Comptonization by the turbulence may therefore dominate over thermal Comptonization in determining the emergent spectrum. We discuss how to self-consistently resolve and interpret this effect in calculations of spectra of radiation MHD simulations. In particular, we show that this effect is dominated by radiation viscous dissipation and can be treated as thermal Comptonization with an equivalent temperature. We investigate whether bulk Comptonization may provide a physical basis for warm Comptonization models of the soft X-ray excess in AGN. We characterize our results with temperatures and optical depths to make contact with other models of this component. We show that bulk Comptonization shifts the Wien tail to higher energy and lowers the gas temperature, broadening the spectrum. More generally, we model the dependence of this effect on a wide range of fundamental accretion disc parameters, such as mass, luminosity, radius, spin, inner boundary condition, and the alpha parameter. Because our model connects bulk Comptonization to one dimensional vertical structure temperature profiles in a physically intuitive way, it will be useful for understanding this effect in future simulations run in new regimes. We also develop a global Monte Carlo code to study this effect in global radiation MHD simulations. This code can be used more broadly to compare global simulations with observed systems, and in particular to investigate whether magnetically dominated discs can explain why observed high Eddington accretion discs appear to be thermally stable.

  13. Unilateral nasal pain with migraine features.

    PubMed

    Alvarez, Mónica; Montojo, Teresa; de la Casa, Beatriz; Vela, Lydia; Pareja, Juan A

    2013-09-01

    Migraine attacks exclusively felt in the face are very rare, the pain involving the territories supplied by the second and third branches of the trigeminal nerve. Two patients suffering from heminasal pain attacks accompanied with typical migrainous features and responsive to oral or intranasal triptans - but not to intranasal lidocaine or oxymetazoline. In one patient, the attacks could be precipitated upon slight touching on the tip of the nose, in the other attacks were preceded by the nasal sensation typically heralding sneezing. Migraine pain mostly develops within the innervation territory of the first branch of the trigeminal nerve, which includes the nose. Therefore, episodes of unilateral nasal pain with migrainous features could be considered a migraine with unusual topography (nasal migraine). Painful nasal attacks occasionally preceded by stimulation of trigeminal afferents in the nose, could be conceived of as migraine-tic syndrome.

  14. Nose and Nasal Planum Neoplasia, Reconstruction.

    PubMed

    Worley, Deanna R

    2016-07-01

    Most intranasal lesions are best treated with radiation therapy. Computed tomographic imaging with intravenous contrast is critical for treatment planning. Computed tomographic images of the nose will best assess the integrity of the cribriform plate for central nervous system invasion by a nasal tumor. Because of an owner's emotional response to an altered appearance of their dog's face, discussions need to include the entire family before proceeding with nasal planectomy or radical planectomy. With careful case selection, nasal planectomy and radical planectomy surgeries can be locally curative. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Measurement of nasal patency in anesthetized and conscious dogs.

    PubMed

    Koss, Michael C; Yu, Yongxin; Hey, John A; McLeod, Robbie L

    2002-02-01

    Experiments were undertaken to characterize a noninvasive chronic, model of nasal congestion in which nasal patency is measured using acoustic rhinometry. Compound 48/80 was administered intranasally to elicit nasal congestion in five beagle dogs either by syringe (0.5 ml) in thiopental sodium-anesthetized animals or as a mist (0.25 ml) in the same animals in the conscious state. Effects of mast cell degranulation on nasal cavity volume as well as on minimal cross-sectional area (A(min)) and intranasal distance to A(min) (D(min)) were studied. Compound 48/80 caused a dose-related decrease in nasal cavity volume and A(min) together with a variable increase in D(min). Maximal responses were seen at 90-120 min. Compound 48/80 was less effective in producing nasal congestion in conscious animals, which also had significantly larger basal nasal cavity volumes. These results demonstrate the utility of using acoustic rhinometry to measure parameters of nasal patency in dogs and suggest that this model may prove useful in studies of the actions of decongestant drugs.

  16. The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects.

    PubMed

    Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen

    2016-06-01

    To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.

  17. Shared-hole graph search with adaptive constraints for 3D optic nerve head optical coherence tomography image segmentation

    PubMed Central

    Yu, Kai; Shi, Fei; Gao, Enting; Zhu, Weifang; Chen, Haoyu; Chen, Xinjian

    2018-01-01

    Optic nerve head (ONH) is a crucial region for glaucoma detection and tracking based on spectral domain optical coherence tomography (SD-OCT) images. In this region, the existence of a “hole” structure makes retinal layer segmentation and analysis very challenging. To improve retinal layer segmentation, we propose a 3D method for ONH centered SD-OCT image segmentation, which is based on a modified graph search algorithm with a shared-hole and locally adaptive constraints. With the proposed method, both the optic disc boundary and nine retinal surfaces can be accurately segmented in SD-OCT images. An overall mean unsigned border positioning error of 7.27 ± 5.40 µm was achieved for layer segmentation, and a mean Dice coefficient of 0.925 ± 0.03 was achieved for optic disc region detection. PMID:29541497

  18. Prognosis of intervertebral disc loss from diagnosis of degenerative disc disease

    NASA Astrophysics Data System (ADS)

    Li, S.; Lin, A.; Tay, K.; Romano, W.; Osman, Said

    2015-03-01

    Degenerative Disc Disease (DDD) is one of the most common causes of low back pain, and is a major factor in limiting the quality of life of an individual usually as they enter older stages of life, the disc degeneration reduces the shock absorption available which in turn causes pain. Disc loss is one of the central processes in the pathogenesis of DDD. In this study, we investigated whether the image texture features quantified from magnetic resonance imaging (MRI) could be appropriate markers for diagnosis of DDD and prognosis of inter-vertebral disc loss. The main objective is to use simple image based biomarkers to perform prognosis of spinal diseases using non-invasive procedures. Our results from 65 subjects proved the higher success rates of the combination marker compared to the individual markers and in the future, we will extend the study to other spine regions to allow prognosis and diagnosis of DDD for a wider region.

  19. CT morphometry of adult thoracic intervertebral discs.

    PubMed

    Fletcher, Justin G R; Stringer, Mark D; Briggs, Christopher A; Davies, Tilman M; Woodley, Stephanie J

    2015-10-01

    Despite being commonly affected by degenerative disorders, there are few data on normal thoracic intervertebral disc dimensions. A morphometric analysis of adult thoracic intervertebral discs was, therefore, undertaken. Archival computed tomography scans of 128 recently deceased individuals (70 males, 58 females, 20-79 years) with no known spinal pathology were analysed to determine thoracic disc morphometry and variations with disc level, sex and age. Reliability was assessed by intraclass correlation coefficients (ICCs). Anterior and posterior intervertebral disc heights and axial dimensions were significantly greater in men (anterior disc height 4.0±1.4 vs 3.6±1.3 mm; posterior disc height 3.6±0.90 vs 3.4±0.93 mm; p<0.01). Disc heights and axial dimensions at T4-5 were similar or smaller than at T2-3, but thereafter increased caudally (mean anterior disc height T4-5 and T10-11, 2.7±0.7 and 5.4±1.2 mm, respectively, in men; 2.6±0.8 and 5.1±1.3 mm, respectively, in women; p<0.05). Except at T2-3, anterior disc height decreased with advancing age and anteroposterior and transverse disc dimensions increased; posterior and middle disc heights and indices of disc shape showed no consistent statistically significant changes. Most parameters showed substantial to almost perfect agreement for intra- and inter-rater reliability. Thoracic disc morphometry varies significantly and consistently with disc level, sex and age. This study provides unique reference data on adult thoracic intervertebral disc morphometry, which may be useful when interpreting pathological changes and for future biomechanical and functional studies.

  20. Hygroscopic condenser humidifier as a solution to nasal dryness due to nasal CPAP treatment for obstructive sleep apnea syndrome.

    PubMed

    Parra, O; Klamburg, J; Xirgu, J; Abad, J; Sala, H; Tomasa, A; Morera, J

    1991-04-01

    We report an apparent solution to nasal dryness for patients with obstructive sleep apnea syndrome treated with nasal continuous positive airway pressure (CPAP) when a hygroscopic condenser humidifier is introduced into the CPAP circuit. Six patients underwent a 5-h test period of nasal CPAP therapy with a mask containing a hygroscopic humidifier. The water vapor showed a statistically significant increase in both inspired and expired gases. The relative humidity of the inspired gases increased significantly. The levels of O2 and CO2 in the respired gases did not change. When patients were asked about nasal dryness at the end of the test, all of them reported marked improvement.

  1. Patient experience with mupirocin or povidone-iodine nasal decolonization.

    PubMed

    Maslow, Jed; Hutzler, Lorraine; Cuff, Germaine; Rosenberg, Andrew; Phillips, Michael; Bosco, Joseph

    2014-06-01

    Led by the federal government, the payers of health care are enacting policies designed to base provider reimbursement on the quality of care they render. This study evaluated and compared patient experiences and satisfaction with nasal decolonization with either nasal povidone-iodine (PI) or nasal mupirocin ointment (MO). A total of 1903 patients were randomized to undergo preoperative nasal decolonization with either nasal MO or PI solution. All randomized patients were also given 2% chlorhexidine gluconate topical wipes. Patients were interviewed prior to discharge to assess adverse events and patient experience with their assigned preoperative antiseptic protocol. Of the 1903 randomized patients, 1679 (88.1%) were interviewed prior to discharge. Of patients receiving PI, 3.4% reported an unpleasant or very unpleasant experience, compared with 38.8% of those using nasal MO (P<.0001). Sixty-seven percent of patients using nasal MO believed it to be somewhat or very helpful in reducing surgical site infections, compared with 71% of patients receiving PI (P>.05). Being recruited as an active participant in surgical site infection prevention was a positive experience for 87.2% of MO patients and 86.3% of PI patients (P=.652). Those assigned to receive PI solution preoperatively reported significantly fewer adverse events than the nasal MO group (P<.01). Preoperative nasal decolonization with either nasal PI or MO was considered somewhat or very helpful by more than two-thirds of patients. Copyright 2014, SLACK Incorporated.

  2. External nasal dilators: definition, background, and current uses

    PubMed Central

    Dinardi, Ricardo Reis; de Andrade, Cláudia Ribeiro; Ibiapina, Cássio da Cunha

    2014-01-01

    Our goal was to revise the literature about external nasal dilators (ENDs) as to their definition, history, and current uses. We reviewed journals in the PubMed and MEDLINE databases. The current uses hereby presented and discussed are physical exercise, nasal congestion and sleep, snoring, pregnancy, cancer, and healthy individuals. Numerous studies have shown that ENDs increase the cross-sectional area of the nasal valve, reducing nasal resistance and transnasal inspiratory pressure and stabilizing the lateral nasal vestibule, avoiding its collapse during final inspiration. These effects also facilitate breathing and are beneficial to patients with nasal obstruction. Furthermore, END use is simple, noninvasive, painless, affordable, and bears minimum risk to the user. Most studies have limited sample size and are mainly focused on physical exercise. In conclusion, ENDs seem useful, so further studies involving potential effects on the performance of physical tests and improvements in sleep quality are necessary, especially in children and teenagers. PMID:25419156

  3. Nasal reaction to changes in whole body temperature.

    PubMed

    Lundqvist, G R; Pedersen, O F; Hilberg, O; Nielsen, B

    1993-11-01

    The changes in nasal patency following a 1.5 degrees C decrease or increase in whole body temperature were measured in 8 healthy young males, during and after 30 min of immersion in a 15 degrees C cold or a 40 degrees C warm bath, breathing air at the same temperature, in a cross-over experimental design. The nasal reactions were traced by consecutive measurements of changes in nasal cavity volumes by acoustic rhinometry. Swelling of the mucosa during cooling and an almost maximal shrinkage of the mucosa during heating were indicated by respectively a decrease and an increase in nasal cavity volumes. The reactions were determined predominantly by the whole body thermal balance, but were also influenced by the temperature of the inhaled air, either enhanced, reduced or temporarily reversed. The greatest change occurred in the nasal cavity, left or right, which differed most from the final state at the beginning of exposure due to the actual state of nasal cycle.

  4. Are Collapsed Cervical Discs Amenable to Total Disc Arthroplasty?: Analysis of Prospective Clinical Data With 2-Year Follow Up.

    PubMed

    Patwardhan, Avinash G; Carandang, Gerard; Voronov, Leonard I; Havey, Robert M; Paul, Gary A; Lauryssen, Carl; Coric, Domagoj; Dimmig, Thomas; Musante, David

    2016-12-15

    Analysis of prospectively collected radiographic data. To investigate the influence of preoperative index-level range of motion (ROM) and disc height on postoperative ROM after cervical total disc arthroplasty (TDA) using compressible disc prostheses. Clinical studies demonstrate benefits of motion preservation over fusion; however, questions remain unanswered as to which preoperative factors have the ability to identify patients who are most likely to have good postoperative motion, which is the primary rationale for TDA. We analyzed prospectively collected data from a single-arm, multicenter study with 2-year follow up of 30 patients with 48 implanted levels. All received compressible cervical disc prostheses of 6 mm-height (M6C, Spinal Kinetics, Sunnyvale, CA). The influence of index-level preoperative disc height and ROM (each with two levels: below-median and above-median) on postoperative ROM was analyzed using 2 x 2 ANOVA. We further analyzed the radiographic outcomes of a subset of discs with preoperative height less than 3 mm, the so-called "collapsed" discs. Shorter (3.0 ± 0.4 mm) discs were significantly less mobile preoperatively than taller (4.4 ± 0.5 mm) discs (6.7° vs. 10.5°, P = 0.01). The postoperative ROM did not differ between the shorter and taller discs (5.6° vs. 5.0°, P = 0.63). Tall discs that were less mobile preoperatively had significantly smaller postoperative ROM than short discs with above-median preoperative mobility (P < 0.05). The "collapsed discs" (n = 8) were less mobile preoperatively compared with all discs combined (5.1° vs. 8.6°, P < 0.01). These discs were distracted to more than two times the preoperative height, from 2.6 to 5.7 mm, and had significantly greater postoperative ROM than all discs combined (7.6° vs. 5.3°, P < 0.05). We observed a significant interaction between preoperative index-level disc height and ROM in influencing postoperative ROM. Although limited by small sample

  5. Disc-halo interactions in ΛCDM

    NASA Astrophysics Data System (ADS)

    Bauer, Jacob S.; Widrow, Lawrence M.; Erkal, Denis

    2018-05-01

    We present a new method for embedding a stellar disc in a cosmological dark matter halo and provide a worked example from a Λ cold dark matter zoom-in simulation. The disc is inserted into the halo at a redshift z = 3 as a zero-mass rigid body. Its mass and size are then increased adiabatically while its position, velocity, and orientation are determined from rigid-body dynamics. At z = 1, the rigid disc (RD) is replaced by an N-body disc whose particles sample a three-integral distribution function (DF). The simulation then proceeds to z = 0 with live disc (LD) and halo particles. By comparison, other methods assume one or more of the following: the centre of the RD during the growth phase is pinned to the minimum of the halo potential, the orientation of the RD is fixed, or the live N-body disc is constructed from a two rather than three-integral DF. In general, the presence of a disc makes the halo rounder, more centrally concentrated, and smoother, especially in the innermost regions. We find that methods in which the disc is pinned to the minimum of the halo potential tend to overestimate the amount of adiabatic contraction. Additionally, the effect of the disc on the subhalo distribution appears to be rather insensitive to the disc insertion method. The LD in our simulation develops a bar that is consistent with the bars seen in late-type spiral galaxies. In addition, particles from the disc are launched or `kicked up' to high galactic latitudes.

  6. Effect of bilastine upon nasal obstruction.

    PubMed

    Dávila, I; Sastre, J; Mullol, J; Montoro, J; Jáuregui, I; Ferrer, M; del Cuvillo, A; Bartra, J; Valero, A

    2011-01-01

    H1 antihistamines constitute one of the main references for the treatment of allergic rhinitis. Classically, these drugs have been considered effective in controlling sneezing, rhinorrhea and itching, though they have not been regarded as particularly effective in application to nasal obstruction. The most recent studies, involving second-generation H1 antihistamines (desloratadine, fexofenadine, levocetirizine, rupatadine), have shown these drugs to offer effects upon nasal obstruction significantly superior to those of placebo. The present review examines the effect of bilastine, a new, potent and highly specific H1 antihistamine without sedative effects or cardiac toxicity, upon nasal obstruction. The analysis of the data from the different clinical trials indicates that in patients with allergic rhinitis, the effect of bilastine upon nasal obstruction is superior to that of placebo and similar to that of other second-generation H1 antihistamines, manifesting within 24 hours after the start of treatment.

  7. The comparative analysis of rocks' resistance to forward-slanting disc cutters and traditionally installed disc cutters

    NASA Astrophysics Data System (ADS)

    Zhang, Zhao-Huang; Fei, Sun; Liang, Meng

    2016-08-01

    At present, disc cutters of a full face rock tunnel boring machine are mostly mounted in the traditional way. Practical use in engineering projects reveals that this installation method not only heavily affects the operation life of disc cutters, but also increases the energy consumption of a full face rock tunnel boring machine. To straighten out this issue, therefore, a rock-breaking model is developed for disc cutters' movement after the research on the rock breaking of forward-slanting disc cutters. Equations of its displacement are established based on the analysis of velocity vector of a disc cutter's rock-breaking point. The functional relations then are brought forward between the displacement parameters of a rock-breaking point and its coordinate through the analysis of micro displacement of a rock-breaking point. Thus, the geometric equations of rock deformation are derived for the forward-slanting installation of disc cutters. With a linear relationship remaining between the acting force and its deformation either before or after the leap breaking, the constitutive relation of rock deformation can be expressed in the form of generalized Hooke law, hence the comparative analysis of the variation in the resistance of rock to the disc cutters mounted in the forward-slanting way with that in the traditional way. It is discovered that with the same penetration, strain of the rock in contact with forward-slanting disc cutters is apparently on the decline, in other words, the resistance of rock to disc cutters is reduced. Thus wear of disc cutters resulted from friction is lowered and energy consumption is correspondingly decreased. It will be useful for the development of installation and design theory of disc cutters, and significant for the breakthrough in the design of full face rock tunnel boring machine.

  8. Automated determination of cup-to-disc ratio for classification of glaucomatous and normal eyes on stereo retinal fundus images

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Nakagawa, Toshiaki; Sawada, Akira; Hatanaka, Yuji; Yamamoto, Tetsuya; Fujita, Hiroshi

    2011-09-01

    Early diagnosis of glaucoma, which is the second leading cause of blindness in the world, can halt or slow the progression of the disease. We propose an automated method for analyzing the optic disc and measuring the cup-to-disc ratio (CDR) on stereo retinal fundus images to improve ophthalmologists' diagnostic efficiency and potentially reduce the variation on the CDR measurement. The method was developed using 80 retinal fundus image pairs, including 25 glaucomatous, and 55 nonglaucomatous eyes, obtained at our institution. A disc region was segmented using the active contour method with the brightness and edge information. The segmentation of a cup region was performed using a depth map of the optic disc, which was reconstructed on the basis of the stereo disparity. The CDRs were measured and compared with those determined using the manual segmentation results by an expert ophthalmologist. The method was applied to a new database which consisted of 98 stereo image pairs including 60 and 30 pairs with and without signs of glaucoma, respectively. Using the CDRs, an area under the receiver operating characteristic curve of 0.90 was obtained for classification of the glaucomatous and nonglaucomatous eyes. The result indicates potential usefulness of the automated determination of CDRs for the diagnosis of glaucoma.

  9. Retinal degeneration in progressive supranuclear palsy measured by optical coherence tomography and scanning laser polarimetry.

    PubMed

    Stemplewitz, Birthe; Kromer, Robert; Vettorazzi, Eik; Hidding, Ute; Frings, Andreas; Buhmann, Carsten

    2017-07-13

    This cross-sectional study compared the retinal morphology between patients with progressive supranuclear palsy (PSP) and healthy controls. (The retinal nerve fiber layer (RNFL) around the optic disc and the retina in the macular area of 22 PSP patients and 151 controls were investigated by spectral domain optical coherence tomography (SD-OCT). Additionally, the RNFL and the nerve fiber index (NFI) were measured by scanning laser polarimetry (SLP). Results of RNFL measurements with SD-OCT and SLP were compared to assess diagnostic discriminatory power. Applying OCT, PSP patients showed a smaller RNFL thickness in the inferior nasal and inferior temporal areas. The macular volume and the thickness of the majority of macular sectors were reduced compared to controls. SLP data showed a thinner RNFL thickness and an increase in the NFI in PSP patients. Sensitivity and specificity to discriminate PSP patients from controls were higher applying SLP than SD-OCT. Retinal changes did not correlate with disease duration or severity in any OCT or SLP measurement. PSP seems to be associated with reduced thickness and volume of the macula and reduction of the RNFL, independent of disease duration or severity. Retinal imaging with SD-OCT and SLP might become an additional tool in PSP diagnosis.

  10. Inhalation of diethylamine--acute nasal effects and subjective response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundqvist, G.R.; Yamagiwa, M.; Pedersen, O.F.

    1992-03-01

    Adult volunteers were exposed to 25 ppm (75 mg/m3) diethylamine in a climate chamber for 15 min in order to study the acute nasal reactions to an exposure equivalent to the present threshold limit value-short-term exposure limit. Changes in nasal volume and nasal resistance were measured by acoustic rhinometry and by rhinomanometry. Acute change in nasal volume, usually seen as acute nasal mucosa response to thermal stimuli, was not observed, nor was an acute change in nasal airway resistance. In a subsequent experiment, the aim was to measure acute sensory effects. Exposure to a concentration increasing from 0 to 12more » ppm took place for 60 min, equal to an average concentration of 10 ppm (30 mg/m3). A moderate to strong olfactory response and distinct nasal and eye irritation were observed. In spite of considerable individual variation, the results were in agreement with sensory effect estimates obtained from animal studies.« less

  11. Revival of the Jumping Disc

    ERIC Educational Resources Information Center

    Ucke, C.; Schlichting, H-J.

    2009-01-01

    Snap discs made of bimetal have many technical applications as thermostats. Jumping discs are a toy version of such snap discs. Besides giving technical information, we describe physical investigations. We show especially how, through simple measurements and calculations, you can determine the initial speed ([approximately equal to]3.5 m…

  12. Chronic Rhinosinusitis with Nasal Polyps

    PubMed Central

    Stevens, Whitney W.; Schleimer, Robert P.; Kern, Robert C.

    2016-01-01

    Chronic rhinosinusitis with nasal polyps (CRSwNP) is an important clinical entity diagnosed by the presence of both subjective and objective evidence of chronic sinonasal inflammation. Symptoms include anterior or posterior rhinorrhea, nasal congestion, hyposmia and/or facial pressure or pain that last for greater than 12 weeks duration. Nasal polyps are inflammatory lesions that project into the nasal airway, are typically bilateral, and originate from the ethmoid sinus. Males are more likely to be affected than females but no specific genetic or environmental factors have been strongly linked to the development of this disorder to date. CRSwNP is frequently associated with asthma and allergic rhinitis but the cellular and molecular mechanisms that contribute to the clinical symptoms are not fully understood. Defects in the sinonasal epithelial cell barrier, increased exposure to pathogenic and colonized bacteria, and dysregulation of the host immune system are all thought to play prominent roles in disease pathogenesis. Additional studies are needed to further explore the clinical and pathophysiological features of CRSwNP so that biomarkers can be identified and novel advances can be made to improve the treatment and management of this disease. PMID:27393770

  13. Bilateral Non-arteritic Anterior Ischaemic Optic Neuropathy as the Presentation of Systemic Amyloidosis.

    PubMed

    Kanaan, M Z; Lorenzi, A R; Thampy, N; Pandit, R; Dayan, Margaret

    2017-12-01

    A 75-year-old hypertensive female with stable idiopathic intermediate uveitis presented with bilateral sequential optic neuropathy with optic disc swelling. The optic neuropathy in the first affected eye (right) was thought to be due to non-arteritic anterior ischaemic optic neuropathy (NAION). Asymptomatic left optic disc swelling was found at routine review 2 months later, and a diagnosis of giant cell arteritis (GCA) was sought. Temporal artery duplex ultrasound showed the "halo sign," but a subsequent temporal artery biopsy showed light-chain (AL) amyloidosis with no signs of giant cell arteritis. In this case, bilateral sequential ischaemic optic neuropathy mimicking non-arteritic anterior ischaemic optic neuropathy was the presenting sign of systemic amyloidosis involving the temporal arteries.

  14. Observability of forming planets and their circumplanetary discs - I. Parameter study for ALMA

    NASA Astrophysics Data System (ADS)

    Szulágyi, J.; Plas, G. van der; Meyer, M. R.; Pohl, A.; Quanz, S. P.; Mayer, L.; Daemgen, S.; Tamburello, V.

    2018-01-01

    We present mock observations of forming planets with Atacama Large Millimeter Array (ALMA). The possible detections of circumplanetary discs (CPDs) were investigated around planets of Saturn, 1, 3, 5, and 10 Jupiter-masses that are placed at 5.2 au from their star. The radiative, 3D hydrodynamic simulations were then post-processed with RADMC3D and the ALMA observation simulator. We found that even though the CPDs are too small to be resolved, they are hot due to the accreting planet in the optically thick limit; therefore, the best chance to detect them with continuum observations in this case is at the shortest ALMA wavelengths, such as band 9 (440 μm). Similar fluxes were found in the case of Saturn and Jupiter-mass planets, as for the 10 MJup gas-giant, due to temperature-weighted optical depth effects: when no deep gap is carved, the planet region is blanketed by the optically thick circumstellar disc leading to a less efficient cooling there. A test was made for a 52 au orbital separation, which showed that optically thin CPDs are also detectable in band 7 but they need longer integration times (>5 h). Comparing the gap profiles of the same simulation at various ALMA bands and the hydro simulation confirmed that they change significantly, first because the gap is wider at longer wavelengths due to decreasing optical depth; secondly, the beam convolution makes the gap shallower and at least 25 per cent narrower. Therefore, caution has to be made when estimating planet masses based on ALMA continuum observations of gaps.

  15. Detecting the optic disc boundary in digital fundus images using morphological, edge detection, and feature extraction techniques.

    PubMed

    Aquino, Arturo; Gegundez-Arias, Manuel Emilio; Marin, Diego

    2010-11-01

    Optic disc (OD) detection is an important step in developing systems for automated diagnosis of various serious ophthalmic pathologies. This paper presents a new template-based methodology for segmenting the OD from digital retinal images. This methodology uses morphological and edge detection techniques followed by the Circular Hough Transform to obtain a circular OD boundary approximation. It requires a pixel located within the OD as initial information. For this purpose, a location methodology based on a voting-type algorithm is also proposed. The algorithms were evaluated on the 1200 images of the publicly available MESSIDOR database. The location procedure succeeded in 99% of cases, taking an average computational time of 1.67 s. with a standard deviation of 0.14 s. On the other hand, the segmentation algorithm rendered an average common area overlapping between automated segmentations and true OD regions of 86%. The average computational time was 5.69 s with a standard deviation of 0.54 s. Moreover, a discussion on advantages and disadvantages of the models more generally used for OD segmentation is also presented in this paper.

  16. Effect of formulation- and administration-related variables on deposition pattern of nasal spray pumps evaluated using a nasal cast.

    PubMed

    Kundoor, Vipra; Dalby, Richard N

    2011-08-01

    To systematically evaluate the effect of formulation- and administration-related variables on nasal spray deposition using a nasal cast. Deposition pattern was assessed by uniformly coating a transparent nose model with Sar-Gel®, which changes from white to purple on contact with water. Sprays were subsequently discharged into the cast, which was then digitally photographed. Images were quantified using Adobe® Photoshop. The effects of formulation viscosity (which influences droplet size), simulated administration techniques (head orientation, spray administration angle, spray nozzle insertion depth), spray pump design and metering volume on nasal deposition pattern were investigated. There was a significant decrease in the deposition area associated with sprays of increasing viscosity. This appeared to be mediated by an increase in droplet size and a narrowing of the spray plume. Administration techniques and nasal spray pump design also had a significant effect on the deposition pattern. This simple color-based method provides quantitative estimates of the effects that different formulation and administration variables may have on the nasal deposition area, and provides a rational basis on which manufacturers of nasal sprays can base their patient instructions or post approval changes when it is impractical to optimize these using a clinical study.

  17. Optic Disc Drusen and Family History of Glaucoma-Results of a Patient-directed Survey.

    PubMed

    Gramer, Gwendolyn; Gramer, Eugen; Weisschuh, Nicole

    2017-10-01

    Prospective evaluation of family history (FH) of glaucoma and FH of optic disc drusen (ODD) in patients with sonographically confirmed ODD. A total of 87 patients with ODD interviewed all their first-degree and second-degree relatives using a detailed questionnaire on whether an ophthalmologist had diagnosed or excluded glaucoma or ocular hypertension (OH). Using a second questionnaire, 62 of these patients also provided information about ODD in their FH. Control groups for FH of glaucoma consisted of 2170 patients with glaucoma or OH evaluated with the same methods and identical questions for FH of glaucoma in a previous study, and of 176 healthy individuals without glaucoma or ODD who were interviewed on family history of glaucoma. Glaucoma in FH was significantly more frequent in patients with ODD with an incidence of 20.7% compared with healthy controls with an incidence of 2.8%, and half as frequent as in glaucoma patients with an incidence of 40%. ODD in FH were found in 9.7% of patients with ODD. As there is a high frequency of family history of glaucoma in patients with ODD, evaluation of FH of ODD and FH of glaucoma is essential in patients with ODD. Glaucoma in FH of ODD patients requires intraocular pressure monitoring and whenever deemed beneficial timely initiation of intraocular pressure-lowering therapy.

  18. Optics for Processes, Products and Metrology

    NASA Astrophysics Data System (ADS)

    Mather, George

    1999-04-01

    Optical physics has a variety of applications in industry, including process inspection, coatings development, vision instrumentation, spectroscopy, and many others. Optics has been used extensively in the design of solar energy collection systems and coatings, for example. Also, with the availability of good CCD cameras and fast computers, it has become possible to develop real-time inspection and metrology devices that can accommodate the high throughputs encountered in modern production processes. More recently, developments in moiré interferometry show great promise for applications in the basic metals and electronics industries. The talk will illustrate applications of optics by discussing process inspection techniques for defect detection, part dimensioning, birefringence measurement, and the analysis of optical coatings in the automotive, glass, and optical disc industries. In particular, examples of optical techniques for the quality control of CD-R, MO, and CD-RW discs will be presented. In addition, the application of optical concepts to solar energy collector design and to metrology by moiré techniques will be discussed. Finally, some of the modern techniques and instruments used for qualitative and quantitative material analysis will be presented.

  19. Enormous disc of cool gas surrounding the nearby powerful radio galaxy NGC612 (PKS0131-36)

    NASA Astrophysics Data System (ADS)

    Emonts, B. H. C.; Morganti, R.; Oosterloo, T. A.; Holt, J.; Tadhunter, C. N.; van der Hulst, J. M.; Ojha, R.; Sadler, E. M.

    2008-06-01

    We present the detection of an enormous disc of cool neutral hydrogen (HI) gas surrounding the S0 galaxy NGC612, which hosts one of the nearest powerful radio sources (PKS0131-36). Using the Australia Telescope Compact Array, we detect MHI = 1.8 × 109Msolar of HI emission-line gas that is distributed in a 140-kpc wide disc-like structure along the optical disc and dust lane of NGC612. The bulk of the gas in the disc appears to be settled in regular rotation with a total velocity range of 850kms-1, although asymmetries in this disc indicate that perturbations are being exerted on part of the gas, possibly by a number of nearby companions. The HI disc in NGC612 suggests that the total mass enclosed by the system is Menc ~ 2.9 × 1012 sin-2 iMsolar, implying that this early-type galaxy contains a massive dark matter halo. We also discuss an earlier study by Holt et al. that revealed the presence of a prominent young stellar population at various locations throughout the disc of NGC612, indicating that this is a rare example of an extended radio source that is hosted by a galaxy with a large-scale star-forming disc. In addition, we map a faint HI bridge along a distance of 400kpc in between NGC612 and the gas-rich (MHI = 8.9 × 109Msolar) barred galaxy NGC619, indicating that likely an interaction between both systems occurred. From the unusual amounts of HI gas and young stars in this early-type galaxy, in combination with the detection of a faint optical shell and the system's high infrared luminosity, we argue that either ongoing or past galaxy interactions or a major merger event are a likely mechanism for the triggering of the radio source in NGC612. This paper is part of an ongoing study to map the large-scale neutral hydrogen properties of nearby radio galaxies and it presents the first example of large-scale HI detected around a powerful Fanaroff-Riley type II (FR-II) radio galaxy. The HI properties of the FR-II radio galaxy NGC612 are very similar to those

  20. Rossby wave instability in astrophysical discs

    NASA Astrophysics Data System (ADS)

    Lovelace, R. V. E.; Romanova, M. M.

    2014-08-01

    A brief review is given of the Rossby wave instability in astrophysical discs. In non-self-gravitating discs, around for example a newly forming stars, the instability can be triggered by an axisymmetric bump at some radius r0 in the disc surface mass-density. It gives rise to exponentially growing non-axisymmetric perturbation (\\propto \\exp \\,({ { i}}m\\phi ) , m = 1,2,…) in the vicinity of r0 consisting of anticyclonic vortices. These vortices are regions of high pressure and consequently act to trap dust particles which in turn can facilitate planetesimal growth in proto-planetary discs. The Rossby vortices in the discs around stars and black holes may cause the observed quasi-periodic modulations of the disc's thermal emission.

  1. Profile and Determinants of Retinal Optical Intensity in Normal Eyes with Spectral Domain Optical Coherence Tomography.

    PubMed

    Chen, Binyao; Gao, Enting; Chen, Haoyu; Yang, Jianling; Shi, Fei; Zheng, Ce; Zhu, Weifang; Xiang, Dehui; Chen, Xinjian; Zhang, Mingzhi

    2016-01-01

    To investigate the profile and determinants of retinal optical intensity in normal subjects using 3D spectral domain optical coherence tomography (SD OCT). A total of 231 eyes from 231 healthy subjects ranging in age from 18 to 80 years were included and underwent a 3D OCT scan. Forty-four eyes were randomly chosen to be scanned by two operators for reproducibility analysis. Distribution of optical intensity of each layer and regions specified by the Early Treatment of Diabetic Retinopathy Study (ETDRS) were investigated by analyzing the OCT raw data with our automatic graph-based algorithm. Univariate and multivariate analyses were performed between retinal optical intensity and sex, age, height, weight, spherical equivalent (SE), axial length, image quality, disc area and rim/disc area ratio (R/D area ratio). For optical intensity measurements, the intraclass correlation coefficient of each layer ranged from 0.815 to 0.941, indicating good reproducibility. Optical intensity was lowest in the central area of retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, inner nuclear layer, outer plexiform layer and photoreceptor layer, except for the retinal pigment epithelium (RPE). Optical intensity was positively correlated with image quality in all retinal layers (0.553<β<0.851, p<0.01), and negatively correlated with age in most retinal layers (-0.362<β<-0.179, p<0.01), except for the RPE (β = 0.456, p<0.01), outer nuclear layer and photoreceptor layer (p>0.05). There was no relationship between retinal optical intensity and sex, height, weight, SE, axial length, disc area and R/D area ratio. There was a specific pattern of distribution of retinal optical intensity in different regions. The optical intensity was affected by image quality and age. Image quality can be used as a reference for normalization. The effect of age needs to be taken into consideration when using OCT for diagnosis.

  2. Developing new automated alternation flicker using optic disc photography for the detection of glaucoma progression

    PubMed Central

    Ahn, J; Yun, I S; Yoo, H G; Choi, J-J; Lee, M

    2017-01-01

    Purpose To evaluate a progression-detecting algorithm for a new automated matched alternation flicker (AMAF) in glaucoma patients. Methods Open-angle glaucoma patients with a baseline mean deviation of visual field (VF) test>−6 dB were included in this longitudinal and retrospective study. Functional progression was detected by two VF progression criteria and structural progression by both AMAF and conventional comparison methods using optic disc and retinal nerve fiber layer (RNFL) photography. Progression-detecting performances of AMAF and the conventional method were evaluated by an agreement between functional and structural progression criteria. RNFL thickness changes measured by optical coherence tomography (OCT) were compared between progressing and stable eyes determined by each method. Results Among 103 eyes, 47 (45.6%), 21 (20.4%), and 32 (31.1%) eyes were evaluated as glaucoma progression using AMAF, the conventional method, and guided progression analysis (GPA) of the VF test, respectively. The AMAF showed better agreement than the conventional method, using GPA of the VF test (κ=0.337; P<0.001 and κ=0.124; P=0.191, respectively). The rates of RNFL thickness decay using OCT were significantly different between the progressing and stable eyes when progression was determined by AMAF (−3.49±2.86 μm per year vs −1.83±3.22 μm per year; P=0.007) but not by the conventional method (−3.24±2.42 μm per year vs −2.42±3.33 μm per year; P=0.290). Conclusions The AMAF was better than the conventional comparison method in discriminating structural changes during glaucoma progression, and showed a moderate agreement with functional progression criteria. PMID:27662466

  3. Effect of early correction of nasal septal deformity in unilateral cleft lip and palate on inferior turbinate hypertrophy and nasal patency.

    PubMed

    Pinto, Valentina; Piccin, Ottavio; Burgio, Luca; Summo, Valeria; Antoniazzi, Elisa; Morselli, Paolo G

    2018-05-01

    A relatively neglected aspect of cleft lip nasal deformity is the effect of septal deviation and inferior turbinate hypertrophy (ITH) on the functional airway. In particular, ITH in the noncleft side can be especially problematic, because it reduces the healthy nasal area, creating bilateral nasal obstruction that might affect the growth of the maxillofacial skeleton. Although these anatomic and functional changes are documented, few recommendations have been developed regarding the proper approach to ITH. The aim of the present study was to asses the ITH severity and determine the degree of nasal airway patency in patients who have undergone primary correction of the nasal septum during lip repair compared to patients operated on without primary septal correction. The study population included two groups. One group consisted of twenty unilateral cleft lip palate UCLP patients who have previously undergone primary rhinoseptoplasty as part of their treatment plan. The control group consisted of twenty UCLP patients operated on without rhinoseptal correction. The Nasal Obstructive Symptom Evaluation (NOSE) scale and nasal endoscopy were used to assess nasal obstruction. The overall untreated group reported severe symptoms across all NOSE scale dimensions more frequently than children who have undergone primary rhinoseptoplasty. The difference was statistically significant for each dimensions (p < 0.05). The mean NOSE score for group A and group B was 21.4 ± 9.4 and 70.8 ± 17.2 respectively (p < 0.0001). In group A turbinate size decreased significantly (p < 0.05) compared to pre-operative data. Comparing the two groups a statistically significant difference in turbinate size was observed (p < 0.0001). The results of the present study confirm that there is a significant degree of ITH and nasal airway dysfunction in patients with UCLP. Early septal repositioning during primary cleft lip repair results in a statistically significant reduction in IT

  4. Reversal of retinal and optic disc ischemia in a patient with sickle cell trait and glaucoma secondary to traumatic hyphema.

    PubMed

    Wax, M B; Ridley, M E; Magargal, L E

    1982-07-01

    A 14-year-old black boy with sickle cell trait, who sustained a traumatic hyphema, developed moderately elevated intraocular pressure that failed to respond to carbonic anhydrase inhibitors and osmotic agents. On the tenth postinjury day, a sudden increased cupping of the optic disc and partial central retinal artery obstruction caused painless loss of vision. Reversal of the cupping, the retinal ischemia, and the intraocular pressure was documented following anterior chamber paracentesis, and visual acuity returned to 6/6. Pathophysiology of the posterior ischemia is discussed. This case documents the potentially debilitating course of traumatic hyphema in "benign" sickle cell trait and its avoidance with proper management. The authors endorse recent suggestions for careful observation of any sickle cell patient with traumatic hyphema, and recommend anterior chamber paracentesis, supplemental oxygen, and avoidance of osmotic agents, if secondary glaucoma develops following the initial trauma.

  5. Optical-spectrum-synthesizer design within an all-optical semiconductor gate to reduce waveform distortion induced by carrier-cooling relaxation at sub-Teraherz frequencies

    NASA Astrophysics Data System (ADS)

    Ueno, Yoshiyasu; Nakamoto, Ryouichi; Sakaguchi, Jun; Suzuki, Rei

    2006-12-01

    In frequency ranges above 200-300 GHz, the second slowest relaxation in the optical response (such as carrier-cooling relaxation having a time constant of 1-2 ps) of a semiconductor optical amplifier inside the conventional delayed-interference signal-wavelength converter (DISC) scheme is thought to start the distortion of all-optically gated waveforms. In this work, we design a digital optical-spectrum-synthesizer block that is part of the expanded DISC scheme. Our numerically calculated spectra, waveforms, and eye diagrams with assumed pseudorandom digital data pulses indicate that this synthesizer significantly removes strong distortion from the gated waveforms. A signal-to-noise ratio of 20 dB was obtained from our random-data eye diagram, providing proof of effectiveness in principle.

  6. A retrospective study of chronic nasal disease in 75 dogs.

    PubMed

    Lobetti, R G

    2009-12-01

    Chronic nasal disease is a common problem in dogs. To determine the aetiology, a retrospective study in 75 dogs with persistent and chronic nasal disease was done. All dogs were evaluated by means of survey nasal radiographs, antegrade and retrograde rhinoscopy, bacterial and fungal cultures, and histopathology. A definitive diagnosis was made in 74/75 cases (98.6%). Nasal neoplasia was the most common diagnosis (46.7%), median age 108 months, followed by lympho-plasmacytic rhinitis (20%), median age 112 months, and fungal rhinitis (10.7%), median age 53.5 months. Other diagnoses included nasal foreign body (5.3%), median age 51 months, and primary bacterial rhinitis (6.7%), median age 116.5 months. Rare aetiologies identified were nasal polyps, granulomatous rhinitis, oro-nasal fistula and naso-pharyngeal stenosis. This study showed that by using a structured combination of survey radiography, rhinoscopy, cultures and histopathology, a diagnosis could be made in dogs with chronic nasal disease.

  7. Nasal reconstruction after epithelioma.

    PubMed

    Rodríguez-Camps, S

    2001-01-01

    In this paper we present our procedure for the treatment, histopathological diagnosis, and resection of skin cancer in the nasal pyramid and its subsequent reconstruction. Because we are dealing with the most important anatomical feature of the face our goal is an aesthetic reconstruction [2,4] according to the anatomical subunits criterion of Burget [3]. First, a histopathological diagnosis is made to determine the nature of the tumor. Then, we proceed with the resection according to the Mohs Micrographic Surgery [1,5,7]. Then we begin with the first step of the nasal reconstruction.

  8. A Comparison of Over-the-Counter Mechanical Nasal Dilators: A Systematic Review.

    PubMed

    Kiyohara, Nicole; Badger, Christopher; Tjoa, Tjoson; Wong, Brian

    2016-09-01

    The internal nasal valve is the narrowest part of the nasal airway and a common site of inspiratory collapse and obstruction of nasal airflow. Over-the-counter mechanical nasal dilators are an alternative to surgical intervention that attempts to improve airflow through the internal nasal valve. To determine the efficacy of over-the-counter mechanical nasal dilators and classify these products by mechanism. A database of 33 available over-the-counter mechanical nasal dilators was generated via a PubMed search as well as an internet search via Amazon.com and Google, conducted from April 1, 2013, through December 31, 2015. Products determined to be unavailable or discontinued were excluded from the database. Of the devices examined in published literature, efficacy was based on objective measures, such as measured airflow, the cross-sectional area of the nasal valve, and changes in resistance. Measures of reported sleep quality or patient perception were excluded. An analysis of each product's mechanism revealed 4 broad classes: external nasal dilator strips, nasal stents, nasal clips, and septal stimulators. A review demonstrated 5 studies supporting the use of external nasal dilator strips, 4 studies supporting the use of nasal clips, 1 study supporting the use of nasal stents, and no studies supporting the use of septal stimulators. Our findings suggest that external nasal dilator strips and nasal clips effectively relieve obstruction of the internal nasal valve and may be an alternative to surgical intervention in some patients.

  9. Dialectal and gender differences in nasalance for a Mandarin population.

    PubMed

    Kim, Ha-Kyung; Yu, Xiao-meng; Cao, Yan-jing; Liu, Xiao-ming; Huang, Zhao-Ming

    2016-01-01

    The purpose of this study was to determine whether there are dialectal and gender related differences in nasalance of main Mandarin vowels and three sentences in 400 Chinese normal adults. The mean nasalance score difference for dialect and gender was significant (p < .001) in all speech materials. For different dialects, the average nasalance scores show that Chongqing > Beijing > Shanghai > Guangzhou for the nasal sentence, oro-nasal sentence, /a/, /i/ and /u/. In addition, the average nasalance scores of females were higher than those of males for all speech materials in all dialects. The clinical significance of this study can be helpful in making nasalance clinical decisions for Chinese people with cleft palate, hearing disorders and dysarthria with resonance disorders. It also shows the theoretical and socio-cultural features for linguists considering dialects and gender.

  10. Response of Preterm Infants to 2 Noninvasive Ventilatory Support Systems: Nasal CPAP and Nasal Intermittent Positive-Pressure Ventilation.

    PubMed

    Silveira, Carmen Salum Thomé; Leonardi, Kamila Maia; Melo, Ana Paula Carvalho Freire; Zaia, José Eduardo; Brunherotti, Marisa Afonso Andrade

    2015-12-01

    Noninvasive ventilation (NIV) in preterm infants is currently applied using intermittent positive pressure (2 positive-pressure levels) or in a conventional manner (one pressure level). However, there are no studies in the literature comparing the chances of failure of these NIV methods. The aim of this study was to evaluate the occurrence of failure of 2 noninvasive ventilatory support systems in preterm neonates over a period of 48 h. A randomized, prospective, clinical study was conducted on 80 newborns (gestational age < 37 weeks, birthweight < 2,500 g). The infants were randomized into 2 groups: 40 infants were treated with nasal CPAP and 40 infants with nasal intermittent positive-pressure ventilation (NIPPV). The occurrence of apnea, progression of respiratory distress, nose bleeding, and agitation was defined as ventilation failure. The need for intubation and re-intubation after failure was also observed. There were no significant differences in birth characteristics between groups. Ventilatory support failure was observed in 25 (62.5%) newborns treated with nasal CPAP and in 12 (30%) newborns treated with NIPPV, indicating an association between NIV failure and the absence of intermittent positive pressure (odds ratio [OR] 1.22, P < .05). Apnea (32.5%) was the main reason for nasal CPAP failure. After failure, 25% (OR 0.33) of the newborns receiving nasal CPAP and 12.5% (OR 0.14) receiving NIPPV required invasive mechanical ventilation. Ventilatory support failure was significantly more frequent when nasal CPAP was used. Copyright © 2015 by Daedalus Enterprises.

  11. The Effect of Menstrual Cycle on Nasal Resonance Characteristics in Females

    ERIC Educational Resources Information Center

    Kumar, Suman; Basu, Shriya; Sinha, Anisha; Chatterjee, Indranil

    2012-01-01

    The purpose of this study was to analyze resonance characteristics (nasality and nasalance values) during the menstrual cycle. Previous studies indicate changes in voice quality and nasal mucosa due to temporary falling estrogen levels in human females during their menstrual cycle. The present study compared the nasality and "nasalance scores"…

  12. [Objective measurement of normal nasality in the Saxony dialect].

    PubMed

    Müller, R; Beleites, T; Hloucal, U; Kühn, M

    2000-12-01

    In the United States of America, the nasometer was developed by Fletcher as an objective method for measuring nasality. There are no accepted normal values for comparable test materials regarding the German language. The aim of this study was the examination of the auditively normal nasality of Saxon-speaking people with the nasometer. The nasalance of 51 healthy Saxon-speaking test persons with auditively normal nasality was measured with a model 6200 nasometer (Kay-Elemetrics, U.S.A.). The text materials used were the vowels "a", "e", "i", "o", and "u", the sentences "Die Schokolade ist sehr lecker" ("The chocolate is very tasty") and "Nenne meine Mama Mimi" ("Name my mama Mimi"), and the texts of "North wind and sun", "A children's birthday", and an arbitrary selection from Strittmatter. The mean nasalance for the vowels was 17.7%, for the sentence containing no nasal sounds 13.0%, and for the sentence containing many nasal sounds 67.2%. The mean value of the texts was 33-41%. The results for the texts agreed well with the results of Reuter (1997), who examined people from the state of Brandenburg. A range from 20% to 55% is suggested as the normal value for nasalance in the German-speaking area.

  13. Disc cell clusters in pathological human intervertebral discs are associated with increased stress protein immunostaining.

    PubMed

    Sharp, Christopher A; Roberts, Sally; Evans, Helena; Brown, Sharon J

    2009-11-01

    Intervertebral disc (IVD) cells within the annulus fibrosus (AF) and nucleus pulposus (NP) maintain distinct functional extracellular matrices and operate within a potentially noxious and stressful environment. How disc cells respond to stress and whether stress is responsible for triggering degeneration is unknown. Disc cell proliferation and cluster formation are most marked in degenerate IVDs, possibly indicating attempts at matrix repair. In other tissues, stress proteins increase rapidly after stress protecting cell function and, although implicated in degeneration of articular cartilage, have received little attention in degenerative IVD pathologies. We have compared the distribution of stress protein immunolocalization in pathological and control IVDs. Disc tissues were obtained at surgery from 43 patients with degenerative disc disease (DDD) and herniation, and 12 controls at postmortem. Tissues were immunostained with a polyclonal antibody for heat shock factor 1 (HSF-1) and monoclonal antibodies for the heat shock proteins, Hsp27 and Hsp72, using an indirect immunoperoxidase method. Positively stained cells were expressed as a percentage of the total. Cell cluster formation was also assessed. The proportion of cells in clusters was similar in the AF (both 2%) and NP (8 and 9%) of control and DDD samples, whereas in herniated tissues this was increased (AF 12%, NP 14%). Stress antigen staining tended to be more frequent in clustered rather than in single/doublet cells, and this was significant (P < 0.005) in both the AF and NP of herniated discs. Clustered cells, which are most common in herniated discs, may be mounting a protective response to abnormal environmental factors associated with disc degeneration. A better understanding of the stress response in IVD cells may allow its utilization in disc cell therapies.

  14. A Nasal Brush-based Classifier of Asthma Identified by Machine Learning Analysis of Nasal RNA Sequence Data.

    PubMed

    Pandey, Gaurav; Pandey, Om P; Rogers, Angela J; Ahsen, Mehmet E; Hoffman, Gabriel E; Raby, Benjamin A; Weiss, Scott T; Schadt, Eric E; Bunyavanich, Supinda

    2018-06-11

    Asthma is a common, under-diagnosed disease affecting all ages. We sought to identify a nasal brush-based classifier of mild/moderate asthma. 190 subjects with mild/moderate asthma and controls underwent nasal brushing and RNA sequencing of nasal samples. A machine learning-based pipeline identified an asthma classifier consisting of 90 genes interpreted via an L2-regularized logistic regression classification model. This classifier performed with strong predictive value and sensitivity across eight test sets, including (1) a test set of independent asthmatic and control subjects profiled by RNA sequencing (positive and negative predictive values of 1.00 and 0.96, respectively; AUC of 0.994), (2) two independent case-control cohorts of asthma profiled by microarray, and (3) five cohorts with other respiratory conditions (allergic rhinitis, upper respiratory infection, cystic fibrosis, smoking), where the classifier had a low to zero misclassification rate. Following validation in large, prospective cohorts, this classifier could be developed into a nasal biomarker of asthma.

  15. Disc Golf: Teaching a Lifetime Activity

    ERIC Educational Resources Information Center

    Eastham, Susan L.

    2015-01-01

    Disc golf is a lifetime activity that can be enjoyed by students of varying skill levels and abilities. Disc golf follows the principles of ball golf but is generally easier for students to play and enjoy success. The object of disc golf is similar to ball golf and involves throwing a disc from the teeing area to the target in as few throws as…

  16. Disposition of nasal, intravenous, and oral methadone in healthy volunteers.

    PubMed

    Dale, Ola; Hoffer, Christine; Sheffels, Pamela; Kharasch, Evan D

    2002-11-01

    Nasal administration of many opioids demonstrates rapid uptake and fast onset of action. Nasal administration may be an alternative to intravenous and oral administration of methadone and was therefore studied in human volunteers. The study was approved by the Institutional Review Board of the University of Washington, Seattle. Eight healthy volunteers (6 men and 2 women) aged 19 to 33 years were enrolled after informed written consent was obtained. Subjects received 10 mg methadone hydrochloride nasally, orally, or intravenously on 3 separate occasions in a crossover design. Nasal methadone (50 mg/mL in aqueous solution) was given as a 100-microL spray in each nostril (Pfeiffer BiDose sprayer). Blood samples for liquid chromatography-mass spectrometry analyses of methadone and the metabolite 2-ethyl-1,5-dimethyl-3,3-diphenylpyrrolinium were drawn for up to 96 hours. The methadone effect was measured by noninvasive infrared pupilometry coincident with blood sampling. Nasal uptake of methadone was rapid, with maximum plasma concentrations occurring within 7 minutes. The maximum effects of intravenous, nasal, and oral methadone, on the basis of dark-adapted pupil diameter, were reached in about 15 minutes, 30 minutes, and 2 hours, respectively. The respective durations were 24, 10, and 8 hours. Both nasal and oral bioavailabilities were 0.85. Subjects reported that nasal methadone caused a burning sensation. Nasal administration of methadone results in rapid absorption and onset of effect and high bioavailability, which was greater than that reported for other nasal opioids, with a similar duration of effect. Nasal administration may be an alternative route of methadone administration; however, improved formulations are desirable to reduce nasal irritation.

  17. Nasal-nanotechnology: revolution for efficient therapeutics delivery.

    PubMed

    Kumar, Amrish; Pandey, Aditya Nath; Jain, Sunil Kumar

    2016-01-01

    In recent years, nanotechnology-based delivery systems have gained interest to overcome the problems of restricted absorption of therapeutic agents from the nasal cavity, depending upon the physicochemical properties of the drug and physiological properties of the human nose. The well-tolerated and non-invasive nasal drug delivery when combined with the nanotechnology-based novel formulations and carriers, opens the way for the effective systemic and brain targeting delivery of various therapeutic agents. To accomplish competent drug delivery, it is imperative to recognize the interactions among the nanomaterials and the nasal biological environment, targeting cell-surface receptors, drug release, multiple drug administration, stability of therapeutic agents and molecular mechanisms of cell signaling involved in patho-biology of the disease under consideration. Quite a few systems have been successfully formulated using nanomaterials for intranasal (IN) delivery. Carbon nanotubes (CNTs), chitosan, polylactic-co-glycolic acid (PLGA) and PLGA-based nanosystems have also been studied in vitro and in vivo for the delivery of several therapeutic agents which shown promising concentrations in the brain after nasal administration. The use of nanomaterials including peptide-based nanotubes and nanogels (NGs) for vaccine delivery via nasal route is a new approach to control the disease progression. In this review, the recent developments in nanotechnology utilized for nasal drug delivery have been discussed.

  18. Nasal septal angiofibroma, a subclass of extranasopharyngeal angiofibroma.

    PubMed

    Garcia-Rodriguez, Laura; Rudman, Kelli; Cogbill, Christopher H; Loehrl, Todd; Poetker, David M

    2012-01-01

    Extranasopharyngeal angiofibromas (ENA) arising from the nasal septum or nasal septal angiofibromas are extremely rare; only 13 such cases have been reported in the international literature. Our objective is to describe the presentation, workup, and surgical management of these lesions. Case reports were done. The setting was a tertiary care referral center and the Veterans Affairs Medical Center. PATIENTS, INTERVENTIONS, AND RESULTS: We present 2 cases of extranasopharyngeal angiofibroma occurring on the nasal septum. In this report, we discuss the occurrence, the histopathologic findings, and the treatment of nasal septal angiofibroma. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Nasal Anatomy

    MedlinePlus

    ... below. The nasal cavity is surrounded by paired, air-filled chambers on each side, and these lie towards the ... and left “choana” and open into a common chamber called the ... When we breathe in, air travels through the nostril, through the right and ...

  20. Total disc replacement for chronic back pain in the presence of disc degeneration.

    PubMed

    Jacobs, Wilco; Van der Gaag, Niels A; Tuschel, Alexander; de Kleuver, Marinus; Peul, Wilco; Verbout, A J; Oner, F Cumhur

    2012-09-12

    In the search for better surgical treatment of chronic low-back pain (LBP) in the presence of disc degeneration, total disc replacement has received increasing attention in recent years. A possible advantage of total disc replacement compared with fusion is maintained mobility at the operated level, which has been suggested to reduce the chance of adjacent segment degeneration. The aim of this systematic review was to assess the effect of total disc replacement for chronic low-back pain in the presence of lumbar disc degeneration compared with other treatment options in terms of patient-centred improvement, motion preservation and adjacent segment degeneration. A comprehensive search in Cochrane Back Review Group (CBRG) trials register, CENTRAL, MEDLINE, EMBASE, BIOSIS, ISI, and the FDA register was conducted. We also checked the reference lists and performed citation tracking of included studies. We included randomised controlled trials (RCTs) comparing total disc replacement with any other intervention for degenerative disc disease. We assessed risk of bias per study using the criteria of the CBRG. Quality of evidence was graded according to the GRADE approach. Two review authors independently selected studies and assessed risk of bias of the studies. Results and upper bounds of confidence intervals were compared against predefined clinically relevant differences. We included 40 publications, describing seven unique RCT's. The follow-up of the studies was 24 months, with only one extended to five years. Five studies had a low risk of bias, although there is a risk of bias in the included studies due to sponsoring and absence of any kind of blinding. One study compared disc replacement against rehabilitation and found a statistically significant advantage in favour of surgery, which, however, did not reach the predefined threshold for clinical relevance. Six studies compared disc replacement against fusion and found that the mean improvement in VAS back pain was

  1. Mapping the accretion disc of the short period eclipsing binary SDSS J0926+3624

    NASA Astrophysics Data System (ADS)

    Schlindwein, Wagner; Baptista, Raymundo

    2018-05-01

    We report the analysis of time-series of optical photometry of SDSS J0926+3624 collected with the Liverpool Robotic Telescope between 2012 February and March while the object was in quiescence. We combined our median eclipse timing with those in the literature to revise the ephemeris and confirm that the binary period is increasing at a rate \\dot{P}=(3.2 ± 0.4)× 10^{-13} s/s. The light curves show no evidence of either the orbital hump produced by a bright spot at disc rim or of superhumps; the average out-of-eclipse brightness level is consistently lower than previously reported. The eclipse map from the average light curve shows a hot white dwarf surrounded by a faint, cool accretion disc plus enhanced emission along the gas stream trajectory beyond the impact point at the outer disc rim, suggesting the occurrence of gas stream overflow/penetration at that epoch. We estimate a disc mass input rate of \\dot{M}=(9 ± 1)× 10^{-12} M_⊙ yr^{-1}, more than an order of magnitude lower than that expected from binary evolution with conservative mass transfer.

  2. Effort of breathing in children receiving high-flow nasal cannula.

    PubMed

    Rubin, Sarah; Ghuman, Anoopindar; Deakers, Timothy; Khemani, Robinder; Ross, Patrick; Newth, Christopher J

    2014-01-01

    High-flow humidified nasal cannula is often used to provide noninvasive respiratory support in children. The effect of high-flow humidified nasal cannula on effort of breathing in children has not been objectively studied, and the mechanism by which respiratory support is provided remains unclear. This study uses an objective measure of effort of breathing (Pressure. Rate Product) to evaluate high-flow humidified nasal cannula in critically ill children. Prospective cohort study. Quaternary care free-standing academic children's hospital. ICU patients younger than 18 years receiving high-flow humidified nasal cannula or whom the medical team planned to extubate to high-flow humidified nasal cannula within 72 hours of enrollment. An esophageal pressure monitoring catheter was placed to measure pleural pressures via a Bicore CP-100 pulmonary mechanics monitor. Change in pleural pressure (ΔPes) and respiratory rate were measured on high-flow humidified nasal cannula at 2, 5, and 8 L/min. ΔPes and respiratory rate were multiplied to generate the Pressure.Rate Product, a well-established objective measure of effort of breathing. Baseline Pes, defined as pleural pressure at end exhalation during tidal breathing, reflected the positive pressure generated on each level of respiratory support. Twenty-five patients had measurements on high-flow humidified nasal cannula. Median age was 6.5 months (interquartile range, 1.3-15.5 mo). Median Pressure,Rate Product was lower on high-flow humidified nasal cannula 8 L/min (median, 329 cm H2O·min; interquartile range, 195-402) compared with high-flow humidified nasal cannula 5 L/min (median, 341; interquartile range, 232-475; p = 0.007) or high-flow humidified nasal cannula 2 L/min (median, 421; interquartile range, 233-621; p < 0.0001) and was lower on high-flow humidified nasal cannula 5 L/min compared with high-flow humidified nasal cannula 2 L/min (p = 0.01). Baseline Pes was higher on high-flow humidified nasal

  3. Nasal hydropulsion: a novel tumor biopsy technique.

    PubMed

    Ashbaugh, Elizabeth A; McKiernan, Brendan C; Miller, Carrie J; Powers, Barbara

    2011-01-01

    Intranasal tumors of dogs and cats pose a diagnostic and therapeutic challenge for small animal practitioners. Multiple nasal biopsy techniques have been described in the past. This report describes a simplified flushing technique to biopsy and debulk nasal tumors, which often also results in immediate clinical relief for the patient. Based on the results of this retrospective study, the authors recommend high-pressure saline hydropulsion as a minimally invasive diagnostic, and potentially therapeutic, technique for nasal tumors in dogs and cats.

  4. Gravitational Instabilities in a Protosolar-like Disc

    NASA Astrophysics Data System (ADS)

    Evans, Mark Graham

    2018-02-01

    This thesis presents a study of protoplanetary discs around young, low mass protostars. Such discs are believed to be massive enough to develop gravitational instabilities, which subsequently form spiral structures. The dynamical and chemical evolutions of a protosolar-like, gravitationally unstable disc are explored and the spiral structure in the disc is found to shock-heat material. This affects the chemical composition via enhanced desorption rates and endothermic reaction rates and through global mixing of the disc. As a result, the gravitational instability in the model disc leads to transient and permanent changes in the disc chemistry, and also provides a chemically-rich midplane in contrast to simulations of more evolved discs. Secondly, radiative transfer calculations are performed for the dust continuum, and model-tailored grid construction is found to improve the accuracy of the resultant flux images. Continuum observations of the model disc are synthesised and the spiral structure (driven by the gravitational instability) is shown to be readily detectable with ALMA across a range of frequencies, disc inclinations and dust opacities. The derivation of disc mass from the observed flux densities is explored but the method commonly utilised is found to be unreliable and underestimate the disc mass. Therefore, it is concluded that gravitational instabilities could be retrospectively validated in discs previously thought not massive enough to be self-gravitating. Finally, radiative transfer calculations are performed for molecular line transitions. Methods for improving the accuracy of line flux images are explored and the validity of assuming local thermodynamic equilibrium is assessed. Observations of the line fluxes are synthesised without noise and the spiral structure is found to be traced to an extent by all transitions considered, which is not necessarily congruent with the underlying distribution of the molecular species. The disc is seen in

  5. Imaginal Disc Abnormalities in Lethal Mutants of Drosophila

    PubMed Central

    Shearn, Allen; Rice, Thomas; Garen, Alan; Gehring, Walter

    1971-01-01

    Late lethal mutants of Drosophila melanogaster, dying after the larval stage of development, were isolated. The homozygous mutant larvae were examined for abnormal imaginal disc morphology, and the discs were injected into normal larval hosts to test their capacities to differentiate into adult structures. In about half of the mutants analyzed, disc abnormalities were found. Included among the abnormalities were missing discs, small discs incapable of differentiating, morphologically normal discs with limited capacities for differentiation, and discs with homeotic transformations. In some mutants all discs were affected, and in others only certain discs. The most extreme abnormal phenotype is a class of “discless” mutants. The viability of these mutant larvae indicates that the discs are essential only for the development of an adult and not of a larva. The late lethals are therefore a major source of mutants for studying the genetic control of disc formation. Images PMID:5002822

  6. The physical relation between disc and coronal emission in quasars

    NASA Astrophysics Data System (ADS)

    Lusso, Elisabeta; Risaliti, Guido

    2017-12-01

    We propose a modified version of the observed non-linear relation between the X-ray (2 keV) and the ultraviolet (2500 Å) emission in quasars (i.e. LX ∝ LUV^γ ) which involves the full width at half-maximum, FWHM, of the broad emission line, i.e. LX ∝ L_UV^γ FWHM^β. By analysing a sample of 550 optically selected non-jetted quasars in the redshift range of 0.36–2.23 from the Sloan Digital Sky Survey cross matched with the XMM-Newton catalogue 3XMM-DR6, we found that the additional dependence of the observed LX ‑ LUV correlation on the FWHM of the MgII broad emission line is statistically significant. Our statistical analysis leads to a much tighter relation with respect to the one neglecting FWHM, and it does not evolve with redshift. We interpret this new relation within an accretion disc corona scenario where reconnection and magnetic loops above the accretion disc can account for the production of the primary X-ray radiation. For a broad line region size depending on the disc luminosity as R_blr ∝ L^0.5 , we find that L_X ∝ L_UV^4/7 FWHM^4/7, which is in very good agreement with the observed correlation.

  7. [Partial nucleotomy of the ovine disc as an in vivo model for disc degeneration].

    PubMed

    Guder, E; Hill, S; Kandziora, F; Schnake, K J

    2009-01-01

    The aim of this study was to develop a suitable animal model for the clinical situation of progressive disc degeneration after microsurgical nucleotomy. Twenty sheep underwent standardised partial anterolateral nucleotomy at lumbar segment 3/4. After randomisation, 10 animals were sacrificed after 12 weeks (group 1). The remainder was sacrificed after 48 weeks (group 2). For radiological examination X-rays, MRI and post-mortem CT scans were performed. Lumbar discs L 3/4 with adjacent subchondral trabecular bone were harvested and analysed macroscopically and histologically. An image-analysing computer program was used to measure histomorphometric indices of bone structure. 17 segments could be evaluated. After 12 weeks (group 1) histological and radiological degenerative disc changes were noted. After 48 weeks (group 2), radiological signs in MRI reached statistical significance. Furthermore, group 2 showed significantly more osteophyte formations in CT scans. Histomorphometric changes of the disc and the adjacent vertebral bone structure suggest a significant progressive degenerative remodelling. The facet joints did not show any osteoarthrosis after 48 weeks. Partial nucleotomy of the ovine lumbar disc leads to radiological and histological signs of disc degeneration similar to those seen in humans after microsurgical nucleotomy. The presented in vivo model may be useful to evaluate new orthopaedic treatment strategies.

  8. Nasal aesthetics: a cross-cultural analysis.

    PubMed

    Broer, Peter N; Buonocore, Samuel; Morillas, Angie; Liu, Jong; Tanna, Neil; Walker, Marc; Ng, Reuben; Ng, Ruben; Persing, John A

    2012-12-01

    Plastic surgeons often approach nasal aesthetic evaluation with the aid of seemingly objective measurements. However, ideal measurements of an attractive nose, as suggested in the literature, might not apply on a cross-cultural basis. Given these controversies, this study aimed to investigate the cultural and ethnic impact on nasal shape preferences. Computerized images of a model's nose were generated in which the nasal width, root, tip, dorsum, and projection of the lips and chin could be altered. A survey containing these images was sent to over 13,000 plastic surgeons and lay people in 50 different countries, with a total response rate of 9.6 percent. Demographic information about the interviewees was obtained. Preferred dimensions of the nose were broken down according to geographic, ethnic, occupational, and sex variables. Interregional comparison revealed that plastic surgeons from Latin America and the Caribbean overall prefer smaller and narrower noses, with more projecting tips, lips, and chins. Similar trends hold true when analyzing results from the general public. Significant differences were found comparing preferences between plastic surgeons and the general public. Plastic surgeons preferred wider nasal roots and tips and, in combination, more projected nasal dorsi, tips, lips, and chins. No universal parameter can define ideal aesthetics of the nose across cultures and ethnic backgrounds. As demonstrated, geographic, ethnic, and cultural factors influence aesthetic perceptions of patients and surgeons.

  9. Nonarteritic anterior ischemic optic neuropathy following pars plana vitrectomy for macular hole treatment: case report.

    PubMed

    Cunha, Leonardo Provetti; Cunha, Luciana Virgínia Ferreira Costa; Costa, Carolina Ferreira; Monteiro, Mário Luiz Ribeiro

    2016-01-01

    Herein, we report a case of nonarteritic anterior ischemic optic neuropathy (NAION) following uneventful pars plana vitrectomy for macular hole treatment. A 56-year-old previously healthy woman presented with a full-thickness macular hole in right eye (OD) and small cup-to-disc ratios in both eyes. Five days after surgery, she noticed sudden painless loss of vision in OD and was found to have an afferent pupillary defect and intraocular pressure of 29 mmHg. Fundus examination showed right optic disc edema and the resolution of a macular hole with an inferior altitudinal visual field defect. Erythrocyte sedimentation rate, C-reactive protein levels, and general physical examination findings were normal. She was treated with hypotensive eyedrops and oral prednisone, resulting in mild visual improvement and a pale optic disc. A combination of face-down position and increased intraocular pressure due to a small optic disc cup were considered as potential mechanisms underlying NAION in the present case. Vitreoretinal surgeons should be aware of NAION as a potentially serious complication and be able to recognize associated risk factors and clinical findings.

  10. Airflow, gas deposition, and lesion distribution in the nasal passages.

    PubMed Central

    Morgan, K T; Monticello, T M

    1990-01-01

    The nasal passages of laboratory animals and man are complex, and lesions induced in the delicate nasal lining by inhaled air pollutants vary considerably in location and nature. The distribution of nasal lesions is generally a consequence of regional deposition of the inhaled material, local tissue susceptibility, or a combination of these factors. Nasal uptake and regional deposition are are influenced by numerous factors including the physical and chemical properties of the inhaled material, such as water solubility and reactivity; airborne concentration and length of exposure; the presence of other air contaminants such as particulate matter; nasal metabolism, and blood and mucus flow. For certain highly water-soluble or reactive gases, nasal airflow patterns play a major role in determining lesion distribution. Studies of nasal airflow in rats and monkeys, using casting and molding techniques combined with a water-dye model, indicate that nasal airflow patterns are responsible for characteristic differences in the distribution of nasal lesions induced by formaldehyde in these species. Local tissue susceptibility is also a complex issue that may be a consequence of many factors, including physiologic and metabolic characteristics of the diverse cell populations that comprise each of the major epithelial types lining the airways. Identification of the principal factors that influence the distribution and nature of nasal lesions is important when attempting the difficult process of determining potential human risks using data derived from laboratory animals. Toxicologic pathologists can contribute to this process by carefully identifying the site and nature of nasal lesions induced by inhaled materials. Images FIGURE 4. FIGURE 6. FIGURE 7. PMID:2200663

  11. Anatomy of the nasal profile

    PubMed Central

    Anderson, K J; Henneberg, M; Norris, R M

    2008-01-01

    There is a lack in the understanding of the variation within the thickness of the soft tissue structures (muscle, skin and fat) overlying the cartilaginous skeleton of the nose and their relationship to the dorsum shape. We examined such relationships by dissecting noses of six adult female and six adult male cadavers, comparing the internal anatomical structures to the external nasal profile. We found that the soft tissue structures differ in thickness along the dorsum and that these differences are individualized. Specifically, continuous presence of subcutaneous fat from root to tip was found in half the sample, one nose had fat only on the tip, another one only on the root, the four others at both positions. The nasalis muscle was identifiable in nine of the 12 noses, transversing the nose in half the sample, and in the remaining three, only the lateral section of the muscle was identified. The superior border of the septal cartilage does not form a linear extension of the profile contour of the nasal bones but angles downwards. The actual profile contour of the dorsum does not follow the profile of the nasal bones or the septal cartilage. These results may influence the current use of nasal guidelines in forensic facial approximation. PMID:19172735

  12. NORMAL NASAL GENE EXPRESSION LEVELS USING CDNA ARRAY TECHNOLOGY

    EPA Science Inventory

    Normal Nasal Gene Expression Levels Using cDNA Array Technology.

    The nasal epithelium is a target site for chemically-induced toxicity and carcinogenicity. To detect and analyze genetic events which contribute to nasal tumor development, we first defined the gene expressi...

  13. The GALAH survey: properties of the Galactic disc(s) in the solar neighbourhood

    NASA Astrophysics Data System (ADS)

    Duong, L.; Freeman, K. C.; Asplund, M.; Casagrande, L.; Buder, S.; Lind, K.; Ness, M.; Bland-Hawthorn, J.; De Silva, G. M.; D'Orazi, V.; Kos, J.; Lewis, G. F.; Lin, J.; Martell, S. L.; Schlesinger, K.; Sharma, S.; Simpson, J. D.; Zucker, D. B.; Zwitter, T.; Anguiano, B.; Da Costa, G. S.; Hyde, E.; Horner, J.; Kafle, P. R.; Nataf, D. M.; Reid, W.; Stello, D.; Ting, Y.-S.; Wyse, R. F. G.

    2018-06-01

    Using data from the GALAH pilot survey, we determine properties of the Galactic thin and thick discs near the solar neighbourhood. The data cover a small range of Galactocentric radius (7.9 ≲ R_GC ≲ 9.5 kpc), but extend up to 4 kpc in height from the Galactic plane, and several kpc in the direction of Galactic anti-rotation (at longitude 260° ≤ ℓ ≤ 280°). This allows us to reliably measure the vertical density and abundance profiles of the chemically and kinematically defined `thick' and `thin' discs of the Galaxy. The thin disc (low-α population) exhibits a steep negative vertical metallicity gradient, at d[M/H]/dz = -0.18 ± 0.01 dex kpc-1, which is broadly consistent with previous studies. In contrast, its vertical α-abundance profile is almost flat, with a gradient of d[α/M]/dz = 0.008 ± 0.002 dex kpc-1. The steep vertical metallicity gradient of the low-α population is in agreement with models where radial migration has a major role in the evolution of the thin disc. The thick disc (high-α population) has a weaker vertical metallicity gradient d[M/H]/dz = -0.058 ± 0.003 dex kpc-1. The α-abundance of the thick disc is nearly constant with height, d[α/M]/dz = 0.007 ± 0.002 dex kpc-1. The negative gradient in metallicity and the small gradient in [α/M] indicate that the high-α population experienced a settling phase, but also formed prior to the onset of major Type Ia supernova enrichment. We explore the implications of the distinct α-enrichments and narrow [α/M] range of the sub-populations in the context of thick disc formation.

  14. Nasal septum perforation of welders.

    PubMed

    Lee, Choong Ryeol; Yoo, Cheol In; Lee, Ji ho; Kang, Seong Kyu

    2002-07-01

    During the periodic physical checkups in 1997-2000, the authors have found eleven cases of nasal septum perforation among 2,869 welders in Ulsan, Korea. They have not suffered from diseases and conditions that could cause septum perforation such as tuberculosis, syphilis, and long-term use of topical corticosteroids. And also they did not have trauma history and surgical experiences on their nasal septum. To investigate the cause of septum perforation we reviewed the past history of pre-employment, the results of annual working environment survey and the material safety data sheets of welding rods and steels with which they have dealt. We also analyzed the concentration of several metals of welding fume and the concentration of blood and urinary chromium. In the result, we assumed that the nasal septum perforation of welders was due to chronic exposure to low-level hexavalent chromium.

  15. Infective endocarditis of native valve after anterior nasal packing.

    PubMed

    Jayawardena, Suriya; Eisdorfer, Jacob; Indulkar, Shalaka; Zarkaria, Muhammad

    2006-01-01

    We present a case report of a patient who was previously treated for spontaneous epistaxis with a petroleum jelly gauze (0.5 in x 72 in) anterior nasal packing filled with an antibiotic ointment, along with prophylactic oral clindamycin. The patient presented with fever and hypotension 3 days after the nasal packing. Her blood cultures grew methicillin-resistant Staphylococcus aureus and the transesophageal echocardiography showed vegetation on the atrial surface of the posterior mitral valve leaflet, confirming the diagnosis of bacterial endocarditis attributable to nasal packing. Several case reports discuss toxic shock syndrome after nasal packing, but none describe endocarditis of the native heart valves subsequent to anterior nasal packing. Current guidelines on endocarditis prophylaxis produced by the American Heart Association, European Cardiac Society, and British Cardiac Society together with published evidence do not recommend endocarditis prophylaxis for patients with native heart valves undergoing anterior nasal packing.

  16. Deep-down ionization of protoplanetary discs

    NASA Astrophysics Data System (ADS)

    Glassgold, A. E.; Lizano, S.; Galli, D.

    2017-12-01

    The possible occurrence of dead zones in protoplanetary discs subject to the magneto-rotational instability highlights the importance of disc ionization. We present a closed-form theory for the deep-down ionization by X-rays at depths below the disc surface dominated by far-ultraviolet radiation. Simple analytic solutions are given for the major ion classes, electrons, atomic ions, molecular ions and negatively charged grains. In addition to the formation of molecular ions by X-ray ionization of H2 and their destruction by dissociative recombination, several key processes that operate in this region are included, e.g. charge exchange of molecular ions and neutral atoms and destruction of ions by grains. Over much of the inner disc, the vertical decrease in ionization with depth into the disc is described by simple power laws, which can easily be included in more detailed modelling of magnetized discs. The new ionization theory is used to illustrate the non-ideal magnetohydrodynamic effects of Ohmic, Hall and Ambipolar diffusion for a magnetic model of a T Tauri star disc using the appropriate Elsasser numbers.

  17. Fast and automatic algorithm for optic disc extraction in retinal images using principle-component-analysis-based preprocessing and curvelet transform.

    PubMed

    Shahbeig, Saleh; Pourghassem, Hossein

    2013-01-01

    Optic disc or optic nerve (ON) head extraction in retinal images has widespread applications in retinal disease diagnosis and human identification in biometric systems. This paper introduces a fast and automatic algorithm for detecting and extracting the ON region accurately from the retinal images without the use of the blood-vessel information. In this algorithm, to compensate for the destructive changes of the illumination and also enhance the contrast of the retinal images, we estimate the illumination of background and apply an adaptive correction function on the curvelet transform coefficients of retinal images. In other words, we eliminate the fault factors and pave the way to extract the ON region exactly. Then, we detect the ON region from retinal images using the morphology operators based on geodesic conversions, by applying a proper adaptive correction function on the reconstructed image's curvelet transform coefficients and a novel powerful criterion. Finally, using a local thresholding on the detected area of the retinal images, we extract the ON region. The proposed algorithm is evaluated on available images of DRIVE and STARE databases. The experimental results indicate that the proposed algorithm obtains an accuracy rate of 100% and 97.53% for the ON extractions on DRIVE and STARE databases, respectively.

  18. Nasal valve evaluation in the Mexican-Hispanic (mestizo) nose.

    PubMed

    Jasso-Ramírez, Elizabeth; Sánchez Y Béjar, Fernando; Arcaute Aizpuru, Fernando; Maulen Radován, Irene E; de la Garza Hesles, Héctor

    2018-04-01

    Our aim in this study was to determine the angle of the internal nasal valve in Mexican patients with the "mestizo nose" feature and without nasal obstructive symptoms. The work was prospective, comparative, and observational in nature and included patients >14 years of age who were seen in the Otolaryngology Department at the Los Angeles Lomas Hospital between April and May 2016. The angle of the internal nasal valve was measured in 30 patients without obstructive symptoms. Endoscopic examination was performed with a 0° endoscope framed with tape at a 13-mm distance from the endoscope's tip, and digital photographs of the internal nasal valve were taken. The measurement of the angle of the internal nasal valve was made in sexagesimal degrees using Golden Ratio v3.1 (2012) software. Statistical analysis was performed using Excel v15.13.3. The angles of the internal nasal valve of the patients were (mean ± standard deviation) 24.07 ± 4.8° for the right nasal cavity and 25.07 ± 5.0° for the left nasal cavity, wider than the angle reported in the normal Caucasian nose established in the literature. According to our results, the Mexican-Hispanic mestizo nose has a wider angle in the internal nasal valve than that considered normal in the literature (10°-15°). We believe it is necessary to undertake a second study and add an airflow resistance measurement with a rhinomanometry procedure so we can compare the results with those in the Caucasian population. © 2018 ARS-AAOA, LLC.

  19. A nasal dermoid sinus in an English bull terrier.

    PubMed

    Burrow, R D

    2004-11-01

    A five-year-old, entire female English bull terrier was presented with a six-week history of intermittent facial swelling and nasal pain, following an incident of nasal trauma. A small opening was present at the mucocutaneous junction on the dorsal nasal planum. Examination under general anaesthesia allowed catheterisation of this opening and confirmed the presence of a tract passing caudally. Plain radiographic examination of the region was unremarkable. Positive contrast sinography demonstrated contrast material filling a midline tract that passed caudally and subcutaneously towards the nasal bone. This tract was surgically excised. Histopathological examination of the excised tissue, together with the clinical findings, led to the diagnosis of nasal dermoid sinus.

  20. Effects of topical nasal steroids and diclofenac on the nasal mucosa during hyperbaric oxygen therapy: a double-blind experimental study.

    PubMed

    Vuralkan, Erkan; Cobanoglu, Hatice Bengu; Arslan, Abdullah; Arslan, Selcuk; Mungan, Sevdegul; Tatar, Selcuk; Toklu, Akın Savas

    2014-08-01

    We aimed to evaluate nasal mucosal changes and efficiency of nasal steroids and diclofenac on nasal mucosa during hyperbaric oxygen (HBO) treatment. Forty adult Albino-Wistar rats were randomized into four groups. Group 1 (control group) (n = 10) not exposed to hyperbaric or enhanced oxygen concentrations; group 2 (HBO group) (n = 10) underwent only HBO treatment; group 3 (n = 10) received HBO and intranasal mometasone furoate (10 μl/day); group 4 (n = 10) treated with HBO and diclofenac sodium (10 mg/kg/day ip). Specimens of nasal mucosa were collected after sacrificing and dissection of animals. The specimens were processed for light microscopic evaluation, and then evaluated histopathologically for fibroblastic proliferation and inflammation. Regarding the scores of inflammation, the level of inflammation in the control group was significantly less severe than the other groups (p < 0.05). Evaluation of the fibrosis scores showed that the scores of both groups 2 and 4 were significantly increased (p < 0.05). There were no statistically significant differences between groups 2, 3, and 4 as for fibrosis and inflammation (p > 0.05). Chronic HBO treatment induced mild inflammation of the nasal mucosa. These effects cannot be prevented adequately by administration of nasal steroids and diclofenac.