Sample records for nasmyth focus instrumentation

  1. SAAO's new robotic telescope and WiNCam (Wide-field Nasmyth Camera)

    NASA Astrophysics Data System (ADS)

    Worters, Hannah L.; O'Connor, James E.; Carter, David B.; Loubser, Egan; Fourie, Pieter A.; Sickafoose, Amanda; Swanevelder, Pieter

    2016-08-01

    The South African Astronomical Observatory (SAAO) is designing and manufacturing a wide-field camera for use on two of its telescopes. The initial concept was of a Prime focus camera for the 74" telescope, an equatorial design made by Grubb Parsons, where it would employ a 61mmx61mm detector to cover a 23 arcmin diameter field of view. However, while in the design phase, SAAO embarked on the process of acquiring a bespoke 1-metre robotic alt-az telescope with a 43 arcmin field of view, which needs a homegrown instrument suite. The Prime focus camera design was thus adapted for use on either telescope, increasing the detector size to 92mmx92mm. Since the camera will be mounted on the Nasmyth port of the new telescope, it was dubbed WiNCam (Wide-field Nasmyth Camera). This paper describes both WiNCam and the new telescope. Producing an instrument that can be swapped between two very different telescopes poses some unique challenges. At the Nasmyth port of the alt-az telescope there is ample circumferential space, while on the 74 inch the available envelope is constrained by the optical footprint of the secondary, if further obscuration is to be avoided. This forces the design into a cylindrical volume of 600mm diameter x 250mm height. The back focal distance is tightly constrained on the new telescope, shoehorning the shutter, filter unit, guider mechanism, a 10mm thick window and a tip/tilt mechanism for the detector into 100mm depth. The iris shutter and filter wheel planned for prime focus could no longer be accommodated. Instead, a compact shutter with a thickness of less than 20mm has been designed in-house, using a sliding curtain mechanism to cover an aperture of 125mmx125mm, while the filter wheel has been replaced with 2 peripheral filter cartridges (6 filters each) and a gripper to move a filter into the beam. We intend using through-vacuum wall PCB technology across the cryostat vacuum interface, instead of traditional hermetic connector-based wiring. This

  2. James Nasmyth, Engineer

    NASA Astrophysics Data System (ADS)

    Nasmyth, James; Smiles, Samuel

    2010-06-01

    Preface; 1. My ancestry; 2. Alexander Nasmyth; 3. An artist's family; 4. My early years; 5. My school-days; 6. Mechanical beginnings; 7. Henry Maudsley, London; 8. Maudsley's private assistant; 9. Holiday in the manufacturing districts; 10. Begin business at Manchester; 11. Bridgewater Foundry - partnership; 12. Free trade in ability - the strike - death of my father; 13. My marriage - the steam hammer; 14. Travels in France and Italy; 15. Steam hammer pile driver; 16. Nuremberg - St. Petersburg - Dannemora; 17. More about Bridgewater Foundry - Woolwich Arsenal; 18. Astronomical pursuits; 19. More about astronomy; 20. Retirement from business; 21. Active leisure; Chronological list of inventions and contrivances; Sun-ray origin of the pyramids, and cuneiform character; Index.

  3. Foco Nasmyth para el telescopio 2,15mts. de CASLEO

    NASA Astrophysics Data System (ADS)

    Casagrande, A. R.

    En principio, este proyecto intenta lograr el mayor aprovechamiento posible del instrumental que se dispone, buscando la manera de optimizar y hacer más eficiente el servicio que brinda el CASLEO a la comunidad astronómica. El mismo consiste en utilizar dispositivos ya existentes en el telescopio, y darle una utilidad. Tal es el caso del camino óptico destinado al foco Coude. Si tenemos en cuenta que disponemos de un tercer espejo Coude, con todos sus mecanismos automatizados, (actualmente sin uso), una distancia apropiada del plano focal, el espacio y el lugar físico necesario para instalar un periférico, es posible la habilitación de un foco Nasmyth en el telescopio 2,15mts. El hecho de contar con este nuevo foco, redundará en importantes beneficios. En primer lugar, posibilitará la observación, casi simultánea, con dos instrumentos. Otro aspecto a tener en cuenta, es que disminuirá el frecuente cambio del instrumental periférico, motivo este que degrada su ideal puesta a punto. Por último, también de interés, es de destacar su escaso costo de ejecución.

  4. Report of the optical conference on the 7.6-meter telescope held in Austin, Texas, March 22 - 24, 1982.

    NASA Astrophysics Data System (ADS)

    Smith, H. J.; Barnes, T. G., III; Tull, R. G.; Nather, R. E.; Angel, R.; Meinel, A.; Macfarlane, M.; Brault, J.; Neugebauer, G.; Gillett, F.; Richardson, E. H.

    Contents: Introductions (H. J. Smith). History of the project (H. J. Smith). Project constraints (T. G. Barnes III).Project constraints (R. G. Tull). Telescope concept (R. E. Nather). Auxiliary instruments (R. E. Nather). Paul-Baker prime focus (R. Angel). Prime focus and Nasmyth cameras (A. Meinel). Nasmyth focal reducers (M. MacFarlane). Spectrometry (R. Angel, R. G. Tull, J. Brault). Infrared sites (G. Neugebauer). IR instrumentation (F. Gillett). Prime focus imaging (E. H. Richardson). Primary mirror figure control (R. G. Tull).

  5. Analysis of polarization introduced due to the telescope optics of the Thirty Meter Telescope

    NASA Astrophysics Data System (ADS)

    Anche, Ramya Manjunath; Sen, Asoke Kumar; Anupama, Gadiyara Chakrapani; Sankarasubramanian, Kasiviswanathan; Skidmore, Warren

    2018-01-01

    An analytical model has been developed to estimate the polarization effects, such as instrumental polarization (IP), crosstalk (CT), and depolarization, due to the optics of the Thirty Meter Telescope. These are estimated for the unvignetted field-of-view and the wavelengths of interest. The model estimates an IP of 1.26% and a CT of 44% at the Nasmyth focus of the telescope at the wavelength of 0.6 μm at field angle zero with the telescope pointing to zenith. Mueller matrices have been estimated for the primary, secondary, and Nasmyth mirrors. It is found that some of the Mueller matrix elements of the primary and secondary mirrors show a fourfold azimuthal antisymmetry, which indicates that the polarization at the Cassegrain focus is negligible. At the inclined Nasmyth mirror, there is no azimuthal antisymmetry in the matrix elements, and this results in nonzero values for IP and CT, which would negatively impact the polarization measurements at the telescope focus. The averaged Mueller matrix is estimated at the Nasmyth focus at different instrument ports and various zenith angles of the telescope. The variation in the Mueller matrix elements for different coatings is also estimated. The impact of this polarization effect on the science case requirements has been discussed. This analysis will help in achieving precise requirements for future instruments with polarimetric capability.

  6. VIMOS Instrument Control Software Design: an Object Oriented Approach

    NASA Astrophysics Data System (ADS)

    Brau-Nogué, Sylvie; Lucuix, Christian

    2002-12-01

    The Franco-Italian VIMOS instrument is a VIsible imaging Multi-Object Spectrograph with outstanding multiplex capabilities, allowing to take spectra of more than 800 objects simultaneously, or integral field spectroscopy mode in a 54x54 arcsec area. VIMOS is being installed at the Nasmyth focus of the third Unit Telescope of the European Southern Observatory Very Large Telescope (VLT) at Mount Paranal in Chile. This paper will describe the analysis, the design and the implementation of the VIMOS Instrument Control System, using UML notation. Our Control group followed an Object Oriented software process while keeping in mind the ESO VLT standard control concepts. At ESO VLT a complete software library is available. Rather than applying waterfall lifecycle, ICS project used iterative development, a lifecycle consisting of several iterations. Each iteration consisted in : capture and evaluate the requirements, visual modeling for analysis and design, implementation, test, and deployment. Depending of the project phases, iterations focused more or less on specific activity. The result is an object model (the design model), including use-case realizations. An implementation view and a deployment view complement this product. An extract of VIMOS ICS UML model will be presented and some implementation, integration and test issues will be discussed.

  7. Implementation of the control electronics for KMOS instrument

    NASA Astrophysics Data System (ADS)

    Hess, Hans-Joachim; Ilijevski, Ivica; Kravcar, Helmut; Richter, Josef; Rühfel, Josef; Schwab, Christoph

    2010-07-01

    The KMOS Instrument is built to be one of the second generation VLT instruments. It is a highly complex multi-object spectrograph for the near infrared. Nearly 60 cryogenic mechanisms have to be controlled. This includes 24 deployable Pick-Off arms, three filter and grating wheels as well as three focus stages and four lamps with an attenuator wheel. These mechanisms and a calibration unit are supervised by three control cabinets based on the VLT standards. To follow the rotation of the Nasmyth adaptor the cabinets are mounted into a Co-rotating structure. The presentation will highlight the requirements on the electronics control and how these are met by new technologies applying a compact and reliable signal distribution. To enable high density wiring within the given space envelope flex-rigid printed circuit board designs have been installed. In addition an electronic system that detects collisions between the moving Pick-Off arms will be presented for safe operations. The control system is designed to achieve two micron resolution as required by optomechanical and flexure constraints. Dedicated LVDT sensors are capable to identify the absolute positions of the Pick- Off arms. These contribute to a safe recovery procedure after power failure or accidental collision.

  8. Post-focus Instrumentation Of The NST

    NASA Astrophysics Data System (ADS)

    Cao, Wenda; Gorceix, N.; Andic, A.; Ahn, K.; Coulter, R.; Goode, P.

    2009-05-01

    The NST (New Solar Telescope), 1.6 m clear aperture, off-axis telescope, is in its commissioning phase at Big Bear Solar Observatory (BBSO). It will be the most capable, largest aperture solar telescope in the US until the 4 m ATST (Advanced Technology Solar Telescope) comes on-line in the middle of the next decade. The NST will be outfitted with state-of-the-art post-focus instrumentation, which currently include Adaptive Optics system (AO), InfraRed Imaging Magnetograph (IRIM), Visible Imaging Magnetograph (VIM), Real-time Image Reconstruction System (RIRS), and Fast Imaging Solar Spectrograph (FISS). A 308 sub-aperture (349-actuator Deformable Mirror) AO system will enable diffraction limited observations over the NST's principal operating wavelengths from 0.4 µm through 1.7 µm. IRIM and VIM are Fabry-Perot based narrow-band tunable filter, which provide high resolution two-dimensional spectroscopic and polarimetric imaging in the near infrared and visible respectively. Using a 32-node parallel computing system, RIRS is capable of performing real-time image reconstruction with one image every minute. FISS is a collaboration between NJIT and Seoul National University to focus on chromosphere dynamics. This instruments would be installed this Summer as a part of the NST commissioning and the implementation of Nysmyth focus instrumentation. Key tasks including optical design, hardware/software integration and subsequent setup/testing on the NST, will be presented in this poster. First light images from the NST will be shown.

  9. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    NASA Technical Reports Server (NTRS)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  10. Focus determination for the James Webb Space Telescope Science Instruments: A Survey of Methods

    NASA Technical Reports Server (NTRS)

    Davila, Pamela S.; Bolcar, Matthew R.; Boss, B.; Dean, B.; Hapogian, J.; Howard, J.; Unger, B.; Wilson, M.

    2006-01-01

    The James Webb Space Telescope (JWST) is a segmented deployable telescope that will require on-orbit alignment using the Near Infrared Camera as a wavefront sensor. The telescope will be aligned by adjusting seven degrees of freedom on each of 18 primary mirror segments and five degrees of freedom on the secondary mirror to optimize the performance of the telescope and camera at a wavelength of 2 microns. With the completion of these adjustments, the telescope focus is set and the optical performance of each of the other science instruments should then be optimal without making further telescope focus adjustments for each individual instrument. This alignment approach requires confocality of the instruments after integration and alignment to the composite metering structure, which will be verified during instrument level testing at Goddard Space Flight Center with a telescope optical simulator. In this paper, we present the results from a study of several analytical approaches to determine the focus for each instrument. The goal of the study is to compare the accuracies obtained for each method, and to select the most feasible for use during optical testing.

  11. Assessment Instrument for Problem-focused Coping. Reliability test of APC. Part 1.

    PubMed

    Tollén, A; Ahlström, G

    1998-01-01

    A new self-report instrument, the Assessment Instrument of Problem-focused Coping (APC) developed from qualitative interviews, is described. This instrument provides knowledge of the patients' own competence in coping with activities of daily living (ADL), the patients' own assessment of what they experience as problems, and the extent to which they are satisfied with their ADL. The purpose of the study was to test the reliability of the instrument with regard to intra-rater reliability and internal consistency. The study group comprised 40 patients with muscular weakness and other symptoms relating to the postpolio syndrome. The result showed an acceptable internal consistency (alpha 0.70), which confirms the construct validity of the instrument. The test-retest showed that the stability over a period of time varied from low to high for a total of 28 items. At the same time, it is evident that the instrument does not achieve the aim of being a good evaluation instrument, because the stability over a period of time was unsatisfactory. The test-retest should be repeated with a larger test group in future research projects.

  12. Technology-enhanced focus groups as a component of instrument development.

    PubMed

    Strout, Tania D; DiFazio, Rachel L; Vessey, Judith A

    2017-06-22

    Background Bullying is a critical public health problem and a screening tool for use in healthcare is needed. Focus groups are a common tool for generating qualitative data when developing an instrument and evidence suggests that technology-enhanced focus groups can be effective in simultaneously engaging participants from diverse settings. Aim To examine the use of technology-enhanced focus groups in generating an item pool to develop a youth-bullying screening tool. Discussion The authors explore methodological and ethical issues related to conducting technology-enhanced focus groups, drawing on their experience in developing a youth-bullying measure. They conducted qualitative focus groups with professionals from the front lines of bullying response and intervention. They describe the experience of conducting technology-enhanced focus group sessions, focusing on the methodological and ethical issues that researchers engaging in similar work may encounter. Challenges associated with this methodology include establishing rapport among participants, privacy concerns and limited non-verbal communication. Conclusion The use of technology-enhanced focus groups can be valuable in obtaining rich data from a wide variety of disciplines and contexts. Organising these focus groups was inexpensive and preferred by the study's participants. Implications for practice Researchers should consider using technology-enhanced focus groups to generate data to develop health-related measurement tools.

  13. Nasmyth Telescope

    NASA Astrophysics Data System (ADS)

    Murdin, P.

    2000-11-01

    An altazimuth reflecting telescope with relatively stable platforms for mounting heavy, large, delicate or developmental equipment which cannot be, or has not been, engineered to cope with attitude changes during the tracking of a star. The optical configuration is the Cassegrain type, with a primary and secondary mirror, and an additional third flat mirror mounted at the intersection of the alti...

  14. Astronomy Meets Biology: EFOSC2 and the Chirality of Life

    NASA Astrophysics Data System (ADS)

    Sterzik, M.; Bagnulo, S.; Azua, A.; Salinas, F.; Alfaro, J.; Vicuna, R.

    2010-12-01

    Homochirality, i.e., the exclusive use of L-amino acids and D-sugar in biological material, induces circular polarisation in the diffuse reflectance spectra of biotic material. Polarimetry may therefore become an interesting remote sensing technique in the future search for extraterrestrial life. We have explored this technique and performed a laboratory experiment making an exotic use of an astronomical instrument. During a period when EFOSC2 was detached from the Nasmyth focus to host a visitor instrument at the NTT, we have observed various samples of biotic and abiotic material and measured their linear and circular polarisation spectra. Among the various targets, we have included samples of the hypolithic cyanobacteria species Chroococcidiopsis isolated from the Coastal Range of the Atacama Desert. To our knowledge, these are the first and highest precision measurements of circular polarisation using living material and obtained with an astronomical instrument.

  15. Use of Adult Patient Focus Groups to Develop the Initial Item Bank for a Cochlear Implant Quality-of-Life Instrument.

    PubMed

    McRackan, Theodore R; Velozo, Craig A; Holcomb, Meredith A; Camposeo, Elizabeth L; Hatch, Jonathan L; Meyer, Ted A; Lambert, Paul R; Melvin, Cathy L; Dubno, Judy R

    2017-10-01

    No instrument exists to assess quality of life (QOL) in adult cochlear implant (CI) users that has been developed and validated using accepted scientific standards. To develop a CI-specific QOL instrument for adults in accordance with the Patient Reported Outcomes Measurement Information System (PROMIS) guidelines. As required in the PROMIS guidelines, patient focus groups participated in creation of the initial item bank. Twenty-three adult CI users were divided into 1 of 3 focus groups stratified by word recognition ability. Three moderator-led focus groups were conducted based on grounded theory on December 3, 2016. Two reviewers independently analyzed focus group recordings and transcripts, with a third reviewer available to resolve discrepancies. All data were reviewed and reported according to the Consolidated Criteria for Reporting Qualitative Research. The setting was a tertiary referral center. Coded focus group data. The 23 focus group participants (10 [43%] female; mean [range] age, 68.1 [46.2-84.2] years) represented a wide range of income levels, education levels, listening modalities, CI device manufacturers, duration of CI use, and age at implantation. Data saturation was determined to be reached before the conclusion of each of the focus groups. After analysis of the transcripts, the central themes identified were communication, emotion, environmental sounds, independence and work function, listening effort, social isolation and ability to socialize, and sound clarity. Cognitive interviews were carried out on 20 adult CI patients who did not participate in the focus groups to ensure item clarity. Based on these results, the initial QOL item bank and prototype were developed. Patient focus groups drawn from the target population are the preferred method of identifying content areas and domains for developing the item bank for a CI-specific QOL instrument. Compared with previously used methods, the use of patient-centered item development for a CI

  16. A Comprehensive Approach Towards Optimizing the Xenon Plasma Focused Ion Beam Instrument for Semiconductor Failure Analysis Applications.

    PubMed

    Subramaniam, Srinivas; Huening, Jennifer; Richards, John; Johnson, Kevin

    2017-08-01

    The xenon plasma focused ion beam instrument (PFIB), holds significant promise in expanding the applications of focused ion beams in new technology thrust areas. In this paper, we have explored the operational characteristics of a Tescan FERA3 XMH PFIB instrument with the aim of meeting current and future challenges in the semiconductor industry. A two part approach, with the first part aimed at optimizing the ion column and the second optimizing specimen preparation, has been undertaken. Detailed studies characterizing the ion column, optimizing for high-current/high mill rate activities, have been described to support a better understanding of the PFIB. In addition, a novel single-crystal sacrificial mask method has been developed and implemented for use in the PFIB. Using this combined approach, we have achieved high-quality images with minimal artifacts, while retaining the shorter throughput times of the PFIB. Although the work presented in this paper has been performed on a specific instrument, the authors hope that these studies will provide general insight to direct further improvement of PFIB design and applications.

  17. Development and initial evaluation of an instrument to assess physiotherapists' clinical reasoning focused on clients' behavior change.

    PubMed

    Elvén, Maria; Hochwälder, Jacek; Dean, Elizabeth; Söderlund, Anne

    2018-05-01

    A systematically developed and evaluated instrument is needed to support investigations of physiotherapists' clinical reasoning integrated with the process of clients' behavior change. This study's aim was to develop an instrument to assess physiotherapy students' and physiotherapists' clinical reasoning focused on clients' activity-related behavior and behavior change, and initiate its evaluation, including feasibility and content validity. The study was conducted in three phases: 1) determination of instrument structure and item generation, based on a model, guidelines for assessing clinical reasoning, and existing measures; 2) cognitive interviews with five physiotherapy students to evaluate item understanding and feasibility; and 3) a Delphi process with 18 experts to evaluate content relevance. Phase 1 resulted in an instrument with four domains: Physiotherapist; Input from client; Functional behavioral analysis; and Strategies for behavior change. The instrument consists of case scenarios followed by items in which key features are identified, prioritized, or interpreted. Phase 2 resulted in revisions of problems and approval of feasibility. Phase 3 demonstrated high level of consensus regarding the instrument's content relevance. This feasible and content-validated instrument shows potential for use in investigations of physiotherapy students' and physiotherapists' clinical reasoning, however continued development and testing are needed.

  18. Recommended conceptual optical system design for China's Large Optical-infrared Telescope (LOT).

    PubMed

    Ma, Donglin

    2018-01-08

    Recently, China is planning to construct a new large optical-infrared telescope (LOT), in which the aperture of the primary mirror is as large as 12m. China's LOT is a general-purpose telescope, which is aimed to work with multiple scientific instruments such as spectrographs. Based on the requirements of LOT telescope, we have compared the performance of Ritchey-Chrétien (RC) design and Aplanatic-Gregorian (AG) design from the perspective of scientific performance and construction cost. By taking the primary focal ratio, Nasmyth focal ratio, and telescope's site condition into consideration, we finally recommend a RC f/1.6 design configuration for LOT's Nasmyth telescope system. Unlike the general identical configuration, we choose a non-identical configuration for the telescope system which has a shorter Cassegrain focal ratio compared to the designed Nasmyth focal ratio. The non-identical design can allow for a shorter back focal distance and therefore a shorter telescope fork to guarantee the gravitational stability of the whole telescope structure, as well as relatively lower construction cost. Detailed analysis for the feasibility of our recommended design is provided in this paper.

  19. Instrumental- and Emotion-Focused Care Work During Physical Health Events: Comparing Gay, Lesbian, and Heterosexual Marriages.

    PubMed

    Umberson, Debra; Thomeer, Mieke Beth; Kroeger, Rhiannon A; Reczek, Corinne; Donnelly, Rachel

    2017-05-01

    We consider emotion- and instrumental-focused care work and marital stress during significant physical health events in midlife gay, lesbian, and heterosexual marriages. We employ the factorial method, an extension of the actor-partner interdependence model, to analyze survey data from 808 midlife gay, lesbian, and heterosexual spouses in 404 unions. The amount of emotion- and instrumental-focused care work provided during physical health events, and the associations between care work and marital stress, depends on the gender of the respondent, gender of the spouse, and whether spouses are in a same-sex or different-sex union. For example, in both same- and different-sex marriages, women report providing more emotion-focused care work during their own health event than do men, and respondents report more health-related marital stress when the patient is a woman. Investigating how midlife same-sex and different-sex spouses care for each other during a spouse's health event expands understandings of gendered aging experiences within marriage. Findings can elucidate health policies and clinical strategies that best support the health of men and women in same- and different-sex marriages. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Optical design of CCAT

    NASA Astrophysics Data System (ADS)

    Cortés-Medellín, Germán; Herter, Terry

    2006-06-01

    The Cornell Caltech Atacama Telescope (CCAT) is a 25m-class sub-millimeter radio telescope capable of operating from 300GHz up to 1.5 THz. The CCAT optical design is an f/8 Ritchey-Chretien (RC) system in a dual Nasmyth focus configuration and a 20 arc-min FOV (diffraction limited imaging performance better than 0.31" at the edge of the field). The large FOV is capable to accommodate up to 1200x1200 (Nyquist Sampled) Pixels at 200 microns, with better than 96% Strehl ratio. The telescope pedestal assembly is a counterbalanced elevation over azimuth design. The main reflector surface is segmented and actively controlled to attain diffraction-limited operation up to 200 microns. A flat Mirror located behind the main reflector vertex provides the optical path relay to either of the two Nasmyth platforms and to a bent-Cassegrain focus for surface calibration. We present the imaging characteristics of the CCAT over the 20arc-min FOV at 200 microns at the Nasmyth focal plane, as well as the positioning sensitivity analysis of CCAT's 3.2m-diameter sub-reflector given in terms of the telescope optical performance, antenna pointing requirements and sub-reflector chopping characteristics.

  1. GIARPS@TNG: GIANO-B and HARPS-N together for a wider wavelength range spectroscopy

    NASA Astrophysics Data System (ADS)

    Claudi, R.; Benatti, S.; Carleo, I.; Ghedina, A.; Guerra, J.; Micela, G.; Molinari, E.; Oliva, E.; Rainer, M.; Tozzi, A.; Baffa, C.; Baruffolo, A.; Buchschacher, N.; Cecconi, M.; Cosentino, R.; Fantinel, D.; Fini, L.; Ghinassi, F.; Giani, E.; Gonzalez, E.; Gonzalez, M.; Gratton, R.; Harutyunyan, A.; Hernandez, N.; Lodi, M.; Malavolta, L.; Maldonado, J.; Origlia, L.; Sanna, N.; Sanjuan, J.; Scuderi, S.; Seemann, U.; Sozzetti, A.; Perez Ventura, H.; Hernandez Diaz, M.; Galli, A.; Gonzalez, C.; Riverol, L.; Riverol, C.

    2017-08-01

    Since 2012, thanks to the installation of the high-resolution echelle spectrograph in the optical range HARPS-N, the Italian telescope TNG (La Palma) became one of the key facilities for the study of the extrasolar planets. In 2014 TNG also offered GIANO to the scientific community, providing a near-infrared (NIR) cross-dispersed echelle spectroscopy covering 0.97-2.45μm at a resolution of 50000. GIANO, although designed for direct light-feed from the telescope at the Nasmyth-B focus, was provisionally mounted on the rotating building and connected via fibers to only available interface at the Nasmyth-A focal plane. The synergy between these two instruments is particularly appealing for a wide range of science cases, especially for the search of exoplanets around young and active stars and the characterisation of their atmosphere. Through the funding scheme "WOW" (a Way to Others Worlds), the Italian National Institute for Astrophysics (INAF) proposed to position GIANO at the focal station for which it was originally designed and the simultaneous use of these spectrographs with the aim to achieve high-resolution spectroscopy in a wide wavelength range (0.383-2.45μm) obtained in a single exposure, giving rise to the project called GIARPS (GIANO-B & HARPS-N). Because of its characteristics, GIARPS can be considered the first and unique worldwide instrument providing not only high resolution in a large wavelength band, but also a high-precision radial velocity measurement both in the visible and in the NIR arm, since in the next future GIANO-B will be equipped with gas absorption cells.

  2. A Policy-Relevant Instrumental Case Study of an Inclusive STEM-Focused High School: Manor New Tech High

    ERIC Educational Resources Information Center

    Lynch, Sharon J.; Spillane, Nancy; House, Ann; Peters-Burton, Erin; Behrend, Tara; Ross, Kathleen M.; Han, Edmund M.

    2017-01-01

    This instrumental case study of Manor New Tech High (MNTH) provides insight and understanding of a trend in U.S. education to create new STEM schools and increase the achievement of students underrepresented in STEM. MNTH was an inclusive, STEM-focused high school, in Manor, Texas. The creation of the school was stimulated by a statewide Texas…

  3. Calibration of EFOSC2 Broadband Linear Imaging Polarimetry

    NASA Astrophysics Data System (ADS)

    Wiersema, K.; Higgins, A. B.; Covino, S.; Starling, R. L. C.

    2018-03-01

    The European Southern Observatory Faint Object Spectrograph and Camera v2 is one of the workhorse instruments on ESO's New Technology Telescope, and is one of the most popular instruments at La Silla observatory. It is mounted at a Nasmyth focus, and therefore exhibits strong, wavelength and pointing-direction-dependent instrumental polarisation. In this document, we describe our efforts to calibrate the broadband imaging polarimetry mode, and provide a calibration for broadband B, V, and R filters to a level that satisfies most use cases (i.e. polarimetric calibration uncertainty 0.1%). We make our calibration codes public. This calibration effort can be used to enhance the yield of future polarimetric programmes with the European Southern Observatory Faint Object Spectrograph and Camera v2, by allowing good calibration with a greatly reduced number of standard star observations. Similarly, our calibration model can be combined with archival calibration observations to post-process data taken in past years, to form the European Southern Observatory Faint Object Spectrograph and Camera v2 legacy archive with substantial scientific potential.

  4. HIRES the high-resolution spectrograph for the E-ELT: dynamics and control of the repositioning mechanism for the E-ELT HIRES polarimeter

    NASA Astrophysics Data System (ADS)

    Di Varano, I.; Strassmeier, K. G.; Woche, M.

    2016-08-01

    A full Stokes dual channel polarimeter for the E-ELT HIRES spectrograph has been envisioned for the intermediate focus f/4.4, operating within a spectral range of 0.4-1.6 μ. It will feed the EELT- HIRES instrument located on the Nasmyth platform via two pairs of dedicated fibers: one fibre pair optimized for the BVRI, the other one optimized for the JH band or any other feasible combination. The instrument must be retractable within a workspace in fulfillment with the ESO requirements on the allocated volume and the dynamic response of the AO tower. For such purpose a swinging arm has been designed with a rotation provided by 5 revolute joints and a jackscrew. Moreover repeatability in repositioning has to be guaranteed by a parallel manipulator, performing an alignment procedure mainly along 5 axes. Dynamics and control criteria with a feed forward chain to compensate for vibration forces and feedback chain for tracking procedure are hereafter presented.

  5. The focusing optics x-ray solar imager (FOXSI): instrument and first flight

    NASA Astrophysics Data System (ADS)

    Krucker, Säm.; Christe, Steven; Glesener, Lindsay; Ishikawa, Shinnosuke; Ramsey, Brian; Gubarev, Mikhail; Saito, Shinya; Takahashi, Tadayuki; Watanabe, Shin; Tajima, Hiroyasu; Tanaka, Takaaki; Turin, Paul; Glaser, David; Fermin, Jose; Lin, Robert P.

    2013-09-01

    Solar flares accelerate particles up to high energies (MeV and GeV scales for electrons and ions, respectively) through efficient acceleration processes that are not currently understood. Hard X-rays (HXRs) are the most direct diagnostic of flare-accelerated electrons. However, past and current solar HXR observers lack the necessary sensitivity and imaging dynamic range to make detailed studies of faint HXR sources in the solar corona (where particle acceleration is thought to occur); these limitations are mainly due to the indirect Fourier imaging techniques used by these observers. With greater sensitivity and dynamic range, electron acceleration sites could be systematically studied in detail. Both these capabilities can be advanced by the use of direct focusing optics. The recently own Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload demonstrates the unique diagnostic power of focusing optics for observations of solar HXRs. FOXSI features grazing-incidence replicated nickel optics with 5 arcsecond resolution and fine-pitch silicon strip detectors with a 7.7 arcsecond strip pitch. FOXSI flew successfully on 2012 November 2, producing images and spectra of a microflare and performing a search for non-thermal emission (4{15 keV) from nanoflares occurring outside active regions in the quiet Sun. A future spacecraft version of FOXSI, featuring similar optics and detectors, could make detailed observations of HXRs from flare-accelerated electrons, identifying and characterizing particle acceleration sites and mapping out paths of energetic electrons as they leave these sites and propagate throughout the solar corona. This paper will describe the FOXSI instrument and present images from the first flight.

  6. Volume phase holographic gratings for the Subaru Prime Focus Spectrograph: performance measurements of the prototype grating set

    NASA Astrophysics Data System (ADS)

    Barkhouser, Robert H.; Arns, James; Gunn, James E.

    2014-08-01

    The Prime Focus Spectrograph (PFS) is a major instrument under development for the 8.2 m Subaru telescope on Mauna Kea. Four identical, fixed spectrograph modules are located in a room above one Nasmyth focus. A 55 m fiber optic cable feeds light into the spectrographs from a robotic fiber positioner mounted at the telescope prime focus, behind the wide field corrector developed for Hyper Suprime-Cam. The positioner contains 2400 fibers and covers a 1.3 degree hexagonal field of view. Each spectrograph module will be capable of simultaneously acquiring 600 spectra. The spectrograph optical design consists of a Schmidt collimator, two dichroic beamsplitters to separate the light into three channels, and for each channel a volume phase holographic (VPH) grating and a dual- corrector, modified Schmidt reimaging camera. This design provides a 275 mm collimated beam diameter, wide simultaneous wavelength coverage from 380 nm to 1.26 µm, and good imaging performance at the fast f/1.1 focal ratio required from the cameras to avoid oversampling the fibers. The three channels are designated as the blue, red, and near-infrared (NIR), and cover the bandpasses 380-650 nm (blue), 630-970 nm (red), and 0.94-1.26 µm (NIR). A mosaic of two Hamamatsu 2k×4k, 15 µm pixel CCDs records the spectra in the blue and red channels, while the NIR channel employs a 4k×4k, substrate-removed HAWAII-4RG array from Teledyne, with 15 µm pixels and a 1.7 µm wavelength cutoff. VPH gratings have become the dispersing element of choice for moderate-resolution astronomical spectro- graphs due their potential for very high diffraction efficiency, low scattered light, and the more compact instru- ment designs offered by transmissive dispersers. High quality VPH gratings are now routinely being produced in the sizes required for instruments on large telescopes. These factors made VPH gratings an obvious choice for PFS. In order to reduce risk to the project, as well as fully exploit the performance

  7. OSIRIS Detectors

    NASA Astrophysics Data System (ADS)

    Joven, E.; Gigante, J.; Beigbeder, F.

    OSIRIS (Optical System for Imaging and Low-Resolution Integrated Spectroscopy) is an instrument designed to obtain images and low-resolution spectra of astronomical objects in the optical domain (from 365-1000 nm). It will be installed on Day One (2004) in the Nasmyth focus of the 10-m Spanish GTC Telescope. The mosaic is composed of two abuttable 2Kx4K CCDs to yield a total of 4Kx4K pixels, 15 μm/pixel, 0.1252 plate scale. The arrangement allows the linking of a classical ARC-GenII controller to a PMC frame-grabber, plugged into a VME-CPU card, where a RTOS (VxWorks from Wind River) is running. Some tests and results, carried out with a couple of MAT44-82 engineering grade devices at room temperature, are given.

  8. Prefocal station mechanical design concept study for the E-ELT

    NASA Astrophysics Data System (ADS)

    Jolley, Paul; Brunetto, Enzo; Frank, Christoph; Lewis, Steffan; Marchetti, Enrico

    2016-07-01

    The Nasmyth platforms of the E-ELT will contain one Prefocal Station (PFS) each. The main PFS functional requirements are to provide a focal plane to the three Nasmyth focal stations and the Coudé focus, optical sensing supporting telescope low order optimisation and seeing limited image quality, and optical sensing supporting characterising and phasing of M1 and other telescope subsystems. The PFS user requirements are used to derive the PFS technical requirements specification that will form the basis for design, development and production of the system. This specification process includes high-level architectural decisions and technical performance budget allocations. The mechanical design concepts reported here have been developed in order to validate key system specifications and associated technical budgets.

  9. The First Light of the Subaru Laser Guide Star Adaptive Optics System

    NASA Astrophysics Data System (ADS)

    Takami, H.; Hayano, Y.; Oya, S.; Hattori, M.; Watanabe, M.; Guyon, O.; Eldred, M.; Colley, S.; Saito, Y.; Itoh, M.; Dinkins, M.

    Subaru Telescope has been operating 36 element curvature sensor AO system for the Cassegrain focus since 2000. We have developed a new AO system for the Nasmyth focus. The AO system has 188 element curvature wavefront sensor and bimorph deformable mirror. It is the largest format system for this type of sensor . The deformable mirror has also 188 element with 90 mm effective aperture and 130 mm blank size. The real time controller is 4 CPU real time Linux OS computer and the update speed is now 1.5 kHz. The AO system also has laser guide star system. The laser is sum frequency solid state laser generating 589 nm light. We have achieved 4.7 W output power with excellent beam quality of M^2=1.1 and good stability. The laser is installed in a clean room on the Nasmyth platform. The laser beam is transferred by photonic crystal optical fiber with 35 m to the 50 cm laser launching telescope mounted behind the Subaru 2ry mirror. The field of view of the low order wavefront sensor for tilt guide star in LGS mode is 2.7 arcmin in diameter. The AO system had the first light with natural guide star in October 2006. The Strehl ratio was > 0.5 at K band under the 0.8 arcsec visible seeing. We also has projected laser beam on the sky during the same engineering run. Three instruments will be used with the AO system. Infrared camera and spectrograph (IRCS), High dynamic range IR camera (HiCIAO) for exosolar planet detection, and visible 3D spectrograph.

  10. Pancreatitis Quality of Life Instrument: Development of a new instrument

    PubMed Central

    Bova, Carol; Barton, Bruce; Hartigan, Celia

    2014-01-01

    Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors). Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use. PMID:26770703

  11. An integrated thermo-structural model to design a polarimeter for the GTC

    NASA Astrophysics Data System (ADS)

    Di Varano, I.; Strassmeier, K. G.; Woche, M.; Laux, U.

    2016-07-01

    The GTC (Gran Telescopio Canarias), with an equivalent aperture of 10.4 m, effective focal length of 169.9 m, located at the Observatorio del Roque de los Muchachos , in La Palma, Canary Islands, will host on its Cassegrain focus the GRAPE polarimeter (GRAntecan PolarimEter). At such focus the plate scale is 1.21 arcsec/mm and the unvignetted FOV 8 arcmin. The instrument will provide full Stokes polarimetry in the spectral range 380-1500 nm, feeding simultaneously up to two spectrographs. At the moment an interface to HORS (High Optical Resolution Spectrograph) is being defined, located on the Nasmyth platform, it has a FWHM resolving power of about 25,000 (5 pixel) within a spectral range of 400-680 nm. The rotator and instrumental flanges for the Cassegrain focus are currently under definition. Hereafter I present the state of art of the mechanical design of the polarimeter, whose strategy is based on an integrated model of Zemax design into ANSYS FEM static and dynamic analyses with thermal loads applied, in order to retrieve tip-tilt, decentering errors and other significant parameters to be looped back to the Zemax model. In such a way it is possible to compare and refine the results achieved through the tolerance analysis.

  12. Design, development, and performance of the fibres of MOONS

    NASA Astrophysics Data System (ADS)

    Guinouard, Isabelle; Avila, Gerardo; Lee, David; Amans, Jean-Philippe; Rees, Phil; Taylor, William; Oliva, Ernesto

    2016-07-01

    The Multi-Object Optical and Near-infrared Spectrograph (MOONS) will exploit the full 500 square arcmin field of view offered by the Nasmyth focus of the Very Large Telescope and will be equipped with two identical triple arm cryogenic spectrographs covering the wavelength range 0.64μm-1.8μm, with a multiplex capability of over 1000 fibres. Each spectrograph will produce spectra for 500 targets simultaneously, each with its own dedicated sky fibre for optimal sky subtraction. The system will have both a medium resolution (R 4000-6000) mode and a high resolution (R 20000) mode. The fibres are used to pick off each sub field of 1" and are used to transport the light from the instrument focal plane to the two spectrographs. Each fibre has a microlens to focus the beam into the fibre at a relative fast focal ratio of F/3.65 to reduce the Focal Ratio Degradation (FRD).

  13. One-stage posterior focus debridement, fusion, and instrumentation in the surgical treatment of lumbar spinal tuberculosis with kyphosis in children.

    PubMed

    Hu, Xiongke; Zhang, Hongqi; Yin, Xinhua; Chen, Yong; Yu, Honggui; Zhou, Zhenhai

    2016-03-01

    The purpose of this study is to investigate the clinical efficacy and feasibility of one-stage posterior focus debridement, fusion, and instrumentation in the surgical treatment of lumbar spinal tuberculosis with kyphosis in children. From December 2007 to May 2012, 13 patients (six males and seven females) suffering from lumbar spinal tuberculosis with kyphosis were admitted. All patients were treated with one-stage posterior focus debridement, fusion, and instrumentation. Then, the clinical efficacy was estimated by statistical analysis based on the data about Frankel grade, the Cobb angle of kyphosis, and erythrocyte sedimentation rate (ESR), which were collected at certain time. The age of all patients ranged from 5 to 13 years (average, 8.8 years). Operation time ranged from 120 to 190 min (average, 165 min). Intraoperative blood loss ranged from 200 to 800 ml (average, 460 ml). All patients were followed up for 24 to 57 months postoperatively (average, 33.5 months). The Cobb angle was changed significantly between preoperation and postoperation (P < 0.05), and there was no significant loss at the last follow-up. The preoperation ESR (62.5 ± 15.7) returned to normal (16.6 ± 8.1) within 3 months postoperatively in all patients (P < 0.05). Bone fusion was achieved within 3-5 months (average, 3.5 months). In the 13 cases, no postoperative severe complications occurred and neurologic function improved in various degrees. The outcomes of follow-up showed that one-stage posterior focus debridement, fusion, and instrumentation can be an effective treatment method for the lumbar spinal tuberculosis with kyphosis in children.

  14. Regional Instrumentation Centers.

    ERIC Educational Resources Information Center

    Cromie, William J.

    1980-01-01

    Focuses on the activities of regional instrumentation centers that utilize the state-of-the-art instruments and methodology in basic scientific research. The emphasis is on the centers involved in mass spectroscopy, magnetic resonance spectroscopy, lasers, and accelerators. (SA)

  15. A new control system hardware architecture for the Hobby-Eberly Telescope prime focus instrument package

    NASA Astrophysics Data System (ADS)

    Ramiller, Chuck; Taylor, Trey; Rafferty, Tom H.; Cornell, Mark E.; Rafal, Marc; Savage, Richard

    2010-07-01

    The Hobby-Eberly Telescope (HET) will be undergoing a major upgrade as a precursor to the HET Dark Energy Experiment (HETDEX‡). As part of this upgrade, the Prime Focus Instrument Package (PFIP) will be replaced with a new design that supports the HETDEX requirements along with the existing suite of instruments and anticipated future additions. This paper describes the new PFIP control system hardware plus the physical constraints and other considerations driving its design. Because of its location at the top end of the telescope, the new PFIP is essentially a stand-alone remote automation island containing over a dozen subsystems. Within the PFIP, motion controllers and modular IO systems are interconnected using a local Controller Area Network (CAN) bus and the CANOpen messaging protocol. CCD cameras that are equipped only with USB 2.0 interfaces are connected to a local Ethernet network via small microcontroller boards running embedded Linux. Links to ground-level systems pass through a 100 m cable bundle and use Ethernet over fiber optic cable exclusively; communications are either direct or through Ethernet/CAN gateways that pass CANOpen messages transparently. All of the control system hardware components are commercially available, designed for rugged industrial applications, and rated for extended temperature operation down to -10 °C.

  16. In-Situ Focusing Inside a Thermal Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Liebe, Carl Christian; Hannah, Brett; Bartman, Randall; Radulescu, Costin; Rud, Mayer; Sarkissian, Edwin; Ho, Timothy; {p; Esposito, Joseph; Sutin, Brian; hide

    2010-01-01

    Traditionally, infrared (IR) space instruments have been focused by iterating with a number of different thickness shim rings in a thermal vacuum chamber until the focus meets requirements. This has required a number of thermal cycles that are very expensive as they tie up many integration and test (I&T)/ environmental technicians/engi neers work ing three shifts for weeks. Rather than creating a test shim for each iteration, this innovation replaces the test shim and can focus the instrument while in the thermal vacuum chamber. The focus tool consists of three small, piezo-actuated motors that drive two sets of mechanical interface flanges between the instrument optics and the focal- plane assembly, and three optical-displacement metrology sensors that can be read from outside the thermal vacuum chamber. The motors are used to drive the focal planes to different focal distances and acquire images, from which it is possible to determine the best focus. At the best focus position, the three optical displacement metrology sensors are used to determine the shim thickness needed. After the instrument leaves the thermal vacuum chamber, the focus tool is replaced with the precision-ground shim ring. The focus tool consists of two sets of collars, one that mounts to the backside of the interface flange of the instrument optics, and one that mounts to the backside of the interface flange of the focal plane modules. The collars on the instrument optics side have the three small piezo-actuated motors and the three optical displacement metrology systems. Before the instrument is focused, there is no shim ring in place and, therefore, no fasteners holding the focal plane modules to the cameras. Two focus tooling collars are held together by three strong springs. The Orbiting Carbon Observatory (OCO) mission spectrometer was focused this way (see figure). The motor described here had to be moved five times to reach an acceptable focus, all during the same thermal cycle, which

  17. Low-cost enclosure for the sub-millimeter telescope

    NASA Astrophysics Data System (ADS)

    Ulich, B. L.; Hoffmann, W. F.; Davison, W. B.; Baars, J. W. M.; Mezger, P. G.

    1984-01-01

    The University of Arizona and the Max-Planck-Institut fuer Radioastronomie are collaborating to construct a submillimeter-wavelength radio telescope facility at the summit of Mt. Lemmon (2791 m above sea level) near Tucson, Arizona. A corotating building has been designed to protect the 10 m-diameter Submillimeter Telescope against storm damage, to provide large instrumentation rooms at the Nasmyth foci, and to minimize degradation of the reflector profile accuracy and pointing errors caused by wind forces and solar radiation.

  18. Low-Cost Enclosure For The Sub-Millimeter Telescope

    NASA Astrophysics Data System (ADS)

    Ulich, Bobby L.; Hoffmann, William F.; Davison, Warren B.; Baars, Jacob W. M.; Mezger, Peter G.

    1983-11-01

    The University of Arizona and the Max-Planck-Institut fur Radioastronomie are collaborating to construct a sub-millimeter wavelength radio telescope facility at the summit of Mt. Lemmon (2791 m above sea level) near Tucson, Arizona. We have designed a corotating building to protect the 10 m diameter Sub-Millimeter Telescope (SMT) against storm damage, to provide large instrumentation rooms at the Nasmyth foci, and to minimize degradation of the reflector profile accuracy and pointing errors caused by wind forces and solar radiation.

  19. A Technological Review of the Instrumented Footwear for Rehabilitation with a Focus on Parkinson’s Disease Patients

    PubMed Central

    Maculewicz, Justyna; Kofoed, Lise Busk; Serafin, Stefania

    2016-01-01

    In this review article, we summarize systems for gait rehabilitation based on instrumented footwear and present a context of their usage in Parkinson’s disease (PD) patients’ auditory and haptic rehabilitation. We focus on the needs of PD patients, but since only a few systems were made with this purpose, we go through several applications used in different scenarios when gait detection and rehabilitation are considered. We present developments of the designs, possible improvements, and software challenges and requirements. We conclude that in order to build successful systems for PD patients’ gait rehabilitation, technological solutions from several studies have to be applied and combined with knowledge from auditory and haptic cueing. PMID:26834696

  20. Fiber IFU unit for the second generation VLT spectrograph KMOS

    NASA Astrophysics Data System (ADS)

    Tomono, Daigo; Weisz, Harald; Hofmann, Reiner

    2003-03-01

    KMOS is a cryogenic multi-object near-infrared spectrograph for the VLT. It will be equipped with about 20 deployable integral field units (IFUs) which can be positioned anywhere in the 7.2 arcmin diameter field o the VLT Nasmyth focus by a cryogenic robot. We describe IFUs using micro lens arrays and optical fibers to arrange the two-dimensional fields from the IFUs on the spectrograph entrance slit. Each micro-lens array is mounted in a spider arm which also houses the pre-optics with a cold stop. The spider arms are positioned by a cryogenic robot which is built around the image plane. For the IFUs, two solutions are considered: monolithic mirco-lens arrays with fibers attached to the back where the entrance pupil is imaged, and tapered fibers with integrated lenses which are bundled together to form a lens array. The flexibility of optical fibers relaxes boundary conditions for integration of the instrument components. On the other hand, FRD and geometric characteristics of optical fibers leads to higher AΩ accepted by the spectrograph. Conceptual design of the instrument is presented as well as advantages and disadvantages of the fiber IFUs.

  1. The Advanced Technology Solar Telescope mount assembly

    NASA Astrophysics Data System (ADS)

    Warner, Mark; Cho, Myung; Goodrich, Bret; Hansen, Eric; Hubbard, Rob; Lee, Joon Pyo; Wagner, Jeremy

    2006-06-01

    When constructed on the summit of Haleakala on the island of Maui, Hawaii, the Advanced Technology Solar Telescope (ATST) will be the world's largest solar telescope. The ATST is a unique design that utilizes a state-of-the-art off-axis Gregorian optical layout with five reflecting mirrors delivering light to a Nasmyth instrument rotator, and nine reflecting mirrors delivering light to an instrument suite located on a large diameter rotating coude lab. The design of the telescope mount structure, which supports and positions the mirrors and scientific instruments, has presented noteworthy challenges to the ATST engineering staff. Several novel design solutions, as well as adaptations of existing telescope technologies to the ATST application, are presented in this paper. Also shown are plans for the control system and drives of the structure.

  2. A mechanical design concept for EAGLE on the revised E-ELT

    NASA Astrophysics Data System (ADS)

    Dubbeldam, Cornelis M.

    2014-07-01

    ESO have recently revisited the design of the E-ELT with a view to reducing cost, leading to de-scopes which include a smaller primary aperture and removal of the Gravity Invariant Focal Station (GIFS). In its original concept, the EAGLE instrument was designed to be located at the GIFS and consequently a major mechanical re-design was required to enable the instrument to be placed on its side in a conventional straight-through Nasmyth configuration. In this paper, a conceptual design for a new instrument structure is presented. A preliminary finite element analysis was carried out to assess the structure's behaviour under operating loading conditions (e.g. gravity loads). The results of this analysis demonstrate that the proposed design is viable, without any significant degradation in performance compared to the original GIFS design.

  3. APF-The Lick Observatory Automated Planet Finder

    DTIC Science & Technology

    2014-04-01

    resolutions up to 150,000. Overall system efficiency (fraction of photons incident on the primary mirror that are detected by the science CCD) on blaze at...A second (currently unused) Nasmyth focus can be quickly accessed via a rotatable tertiary mirror . The telescope uses a 2.41 m diameter f=1:5 primary...within 0.5″, and 90% encircled energy within 1″. The mount for the secondary mirror M2 incorporates an active tip/tilt and focus system that corrects for

  4. Intensity interferometry with Aqueye+ and Iqueye in Asiago

    NASA Astrophysics Data System (ADS)

    Zampieri, Luca; Naletto, Giampiero; Barbieri, Cesare; Barbieri, Mauro; Verroi, Enrico; Umbriaco, Gabriele; Favazza, Paolo; Lessio, Luigi; Farisato, Giancarlo

    2016-08-01

    Since a number of years our group is engaged in the design, construction and operation of instruments with very high time resolution in the optical band for applications to Quantum Astronomy and more conventional Astrophysics. Two instruments were built to perform photon counting with sub-nanosecond temporal accuracy. The first of the two, Aqueye+, is regularly mounted at the 1.8 m Copernicus telescope in Asiago, while the second one, Iqueye, was mounted at the ESO New Technology Telescope in Chile, and at the William Herschel Telescope and Telescopio Nazionale Galileo on the Roque (La Palma, Canary Islands). Both instruments deliver extraordinarily accurate results in optical pulsar timing. Recently, Iqueye was moved to Asiago to be mounted at the 1.2 m Galileo telescope to attempt, for the first time ever, experiments of optical intensity interferometry (à la Hanbury Brown and Twiss) on a baseline of a few kilometers, together with the Copernicus telescope. This application was one of the original goals for the development of our instrumentation. To carry out these measurements, we are experimenting a new way of coupling the instruments to the telescopes, by means of moderate-aperture, low-optical-attenuation multi-mode optical fibers with a double-clad design. Fibers are housed in dedicated optical interfaces attached to the focus of another instrument of the 1.8 m telescope (Aqueye+) or to the Nasmyth focus of the 1.2 m telescope (Iqueye). This soft-mount solution has the advantage to facilitate the mounting of the photon counters, to keep them under controlled temperature and humidity conditions (reducing potential systematics related to varying ambient conditions), and to mitigate scheduling requirements. Here we will describe the first successful implementation of the Asiago intensity interferometer and future plans for improving it.

  5. The speckle polarimeter of the 2.5-m telescope: Design and calibration

    NASA Astrophysics Data System (ADS)

    Safonov, B. S.; Lysenko, P. A.; Dodin, A. V.

    2017-05-01

    The speckle polarimeter is a facility instrument of the 2.5-mSAIMSU telescope that combines the features of a speckle interferometer and a polarimeter. The speckle polarimeter is designed for observations in several visible bands in the following modes: speckle interferometry, polarimetry, speckle polarimetry, and polaroastrometry. In this paper we describe the instrument design and the procedures for determining the angular scale of the camera and the position angle of the camera and the polarimeter. Our measurements of the parameters for the binary star HD 9165 are used as an example to demonstrate the technique of speckle interferometry. For bright objects the accuracy of astrometry is limited by the error of the correction for the distortion caused by the atmospheric dispersion compensator. At zenith distances less than 45◦ the additional relative measurement error of the separation is 0.7%, while the additional error of the position angle is 0.3°. In the absence of a dispersion compensator the accuracy of astrometry is limited by the uncertainty in the scale and position angle of the camera, which are 0.15% and 0.06°, respectively. We have performed polarimetric measurements of unpolarized stars and polarization standards. The instrumental polarization at the Cassegrain focus in the V band does not exceed 0.01%. The instrumental polarization for the Nasmyth focus varies between 2 and 4% within the visible range; we have constructed its model and give a method for its elimination from the measurements. For stars with an intrinsic polarization of less than 0.2% during observations at the Cassegrain focus the error is determined mainly by the photon and readout noises and can reach 5 × 10-5.

  6. Portable instrument for inspecting irradiated nuclear fuel assemblies

    DOEpatents

    Nicholson, Nicholas; Dowdy, Edward J.; Holt, David M.; Stump, Jr., Charles J.

    1985-01-01

    A portable instrument for measuring induced Cerenkov radiation associated with irradiated nuclear fuel assemblies in a water-filled storage pond is disclosed. The instrument includes a photomultiplier tube and an image intensifier which are operable in parallel and simultaneously by means of a field lens assembly and an associated beam splitter. The image intensifier permits an operator to aim and focus the apparatus on a submerged fuel assembly. Once the instrument is aimed and focused, an illumination reading can be obtained with the photomultiplier tube. The instrument includes a lens cap with a carbon-14/phosphor light source for calibrating the apparatus in the field.

  7. The James Clerk Maxwell telescope - United Kingdom/Netherlands 15-metre antenna

    NASA Astrophysics Data System (ADS)

    Hills, R.

    The 15-m James Clerk Maxwell (JCM) radiotelescope being installed on Mauna Kea was designed to achieve 35 micron surface accuracy and 1 arcsec rms tracking accuracy and relative pointing accuracy at frequencies over 700 GHz. The instrument will be housed in a steel building for protection against the occasionally severe weather. The surface of the antenna consists of 276 Al panels adhered to honeycombs beneath which is glued a second Al skin for stiffness. The temperature-controlled housing and insulation between layers will strongly inhibit distortions due to environmental temperature changes and thermal gradients between front and back layers. An all-steel frame was selected to further minimize temperature induced pointing aberrations. Adjustments can be made with the three jacking screws with which each panel is fitted. An f/12 Cassegrain focus behind the primary mirror is large enough for mounting up to four receivers, and another receiver can be sited at the f/35 Nasmyth focus at the side of the mount. Two Schottky diode receivers are currently being fabricated 220-280 GHz and 330-360 GHz measurements, and will be followed by InSb mixers for 460-490 GHz and 660-720 GHz.

  8. Critical Science Instrument Alignment of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    NASA Technical Reports Server (NTRS)

    Rohrbach, Scott O.; Kubalak, David A.; Gracey, Renee M.; Sabatke, Derek S.; Howard, Joseph M.; Telfer, Randal C.; Zielinski, Thomas P.

    2016-01-01

    This paper describes the critical instrument alignment terms associated with the six-degree of freedom alignment of each the Science Instrument (SI) in the James Webb Space Telescope (JWST), including focus, pupil shear, pupil clocking, and boresight. We present the test methods used during cryogenic-vacuum tests to directly measure the performance of each parameter, the requirements levied on each, and the impact of any violations of these requirements at the instrument and Observatory level.

  9. Instrument and method for focusing X-rays, gamma rays and neutrons

    DOEpatents

    Smither, Robert K.

    1984-01-01

    A crystal diffraction instrument or diffraction grating instrument with an improved crystalline structure or grating spacing structure having a face for receiving a beam of photons or neutrons and diffraction planar spacing or grating spacing along that face with the spacing increasing progressively along the face to provide a decreasing Bragg diffraction angle for a monochromatic radiation and thereby increasing the usable area and acceptance angle. The increased planar spacing for the diffraction crystal is provided by the use of a temperature differential across the crystalline structure, by assembling a plurality of crystalline structures with different compositions, by an individual crystalline structure with a varying composition and thereby a changing planar spacing along its face, and by combinations of these techniques. The increased diffraction grating element spacing is generated during the fabrication of the diffraction grating by controlling the cutting tool that is cutting the grooves or controlling the laser beam, electron beam or ion beam that is exposing the resist layer, etc. It is also possible to vary this variation in grating spacing by applying a thermal gradient to the diffraction grating in much the same manner as is done in the crystal diffraction case.

  10. Instrument and method for focusing x rays, gamma rays, and neutrons

    DOEpatents

    Smither, R.K.

    1982-03-25

    A crystal-diffraction instrument or diffraction-grating instrument is described with an improved crystalline structure or grating spacing structure having a face for receiving a beam of photons or neutrons and diffraction planar spacing or grating spacing along that face with the spacing increasing progressively along the face to provide a decreasing Bragg diffraction angle for a monochromatic radiation and thereby increasing the usable area and acceptance angle. The increased planar spacing for the diffraction crystal is provided by the use of a temperature differential across the line structures with different compositions, by an individual crystalline structure with a varying composition and thereby a changing planar spacing along its face, and by combinations of these techniques. The increased diffraction grating element spacing is generated during the fabrication of the diffraction grating by controlling the cutting tool that is cutting the grooves or controlling the laser beam, electron beam, or ion beam that is exposing the resist layer, etc. It is also possible to vary this variation in grating spacing by applying a thermal gradient to the diffraction grating in much the same manner as is done in the crystal-diffraction case.

  11. A Modular and Configurable Instrument Electronics Architecture for "MiniSAR"- An Advanced Smallsat SAR Instrument

    NASA Astrophysics Data System (ADS)

    Gomez, Jaime; Pastena, Max; Bierens, Laurens

    2013-08-01

    MiniSAR is a Dutch program focused on the development of a commercial smallsat featuring a SAR instrument, led by SSBV as prime contractor. In this paper an Instrument Electronics (IEL) system concept to meet the MiniSAR demands is presented. This system has several specificities wrt similar initiatives in the European space industry, driven by our main requirement: keep it small.

  12. One-Meter Telescope in Kolonica Saddle - 4 Years of Operation

    NASA Astrophysics Data System (ADS)

    Kudzej, I.; Dubovsky, P. A.

    2010-12-01

    The actual technical status of 1 meter Vihorlat National Telescope (VNT) at Astronomical Observatory at Kolonica Saddle is presented. Cassegrain and Nasmyth focus, autoguiding system, computer controlled focusing and fine movements and other improvements achieved recently. For two channel photoelectric photometer the system of channels calibration based on artificial light source is described. For CCD camera FLI PL1001E actually installed in Cassegrain focus we presents transformation coefficients from our instrumental to international photometric BVRI system. The measurements were done during regular observations when good photometry of the constant field stars was available. Before FLI camera acquisition we used SBIG ST9 camera. Transformation coefficients for this instrument are presented as well. In the second part of the paper we presents results of variable stars observations with 1 meter telescope in recent four years. The first experimental electronic measurements were done in 2006. Both with CCD cameras and with two channel photoelectric photometer. Starting in 2007 the regular observing program is in operation. There are only few stars suitable for two channel photoelectric photometer observation. Generally the photometer is better when fast brightness changes (time scale of seconds) must be recorded. Thus the majority of observations is done with CCD detectors. We presents an brief overview of most important observing programs: long term monitoring of selected intermediate polars, eclipse observations of SW Sex stars. Occasional observing campaigns were performed on several interesting objects: OT J071126.0+440405, V603 Aql, V471 Tau eclipse timings, Z And in outburst.

  13. Instrumentation and fusion for congenital spine deformities.

    PubMed

    Hedequist, Daniel J

    2009-08-01

    A retrospective clinical review. To review the use of modern instrumentation of the spine for congenital spinal deformities. Spinal instrumentation has evolved since the advent of the Harrington rod. There is a paucity of literature, which discusses the use of modern spinal instrumentation in congenital spine deformity cases. This review focuses on modern instrumentation techniques for congenital scoliosis and kyphosis. A systematic review was performed of the literature to discuss spinal implant use for congenital deformities. Spinal instrumentation may be safely and effectively used in cases of congenital spinal deformity. Spinal surgeons taking care of children with congenital spine deformities need to be trained in all aspects of modern spinal instrumentation.

  14. Cooling the dark energy camera instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitt, R.L.; Cease, H.; /Fermilab

    2008-06-01

    DECam, camera for the Dark Energy Survey (DES), is undergoing general design and component testing. For an overview see DePoy, et al in these proceedings. For a description of the imager, see Cease, et al in these proceedings. The CCD instrument will be mounted at the prime focus of the CTIO Blanco 4m telescope. The instrument temperature will be 173K with a heat load of 113W. In similar applications, cooling CCD instruments at the prime focus has been accomplished by three general methods. Liquid nitrogen reservoirs have been constructed to operate in any orientation, pulse tube cryocoolers have been usedmore » when tilt angles are limited and Joule-Thompson or Stirling cryocoolers have been used with smaller heat loads. Gifford-MacMahon cooling has been used at the Cassegrain but not at the prime focus. For DES, the combined requirements of high heat load, temperature stability, low vibration, operation in any orientation, liquid nitrogen cost and limited space available led to the design of a pumped, closed loop, circulating nitrogen system. At zenith the instrument will be twelve meters above the pump/cryocooler station. This cooling system expected to have a 10,000 hour maintenance interval. This paper will describe the engineering basis including the thermal model, unbalanced forces, cooldown time, the single and two-phase flow model.« less

  15. Focused Observation and Feedback of Nonverbal Behavior.

    ERIC Educational Resources Information Center

    Field, Judd F.; Bradley, Banks T.

    A feedback and analysis instrument measuring nonverbal teacher behavior is presented which focuses on fourteen specific behaviors. Data obtained from the instrument may be analyzed for each of the behaviors and developed into a quantified ratio of those categories tending to signal positive influence by the teacher toward the pupil and those…

  16. Life support subsystem monitoring instrumentation

    NASA Technical Reports Server (NTRS)

    Powell, J. D.; Kostell, G. D.

    1974-01-01

    The recognition of the need for instrumentation in manned spacecraft life-support subsystems has increased significantly over the past several years. Of the required control and monitoring instrumentation, this paper will focus on the monitoring instrumentation as applied to life-support subsystems. The initial approach used independent sensors, independent sensor signal conditioning circuitry, and independent logic circuitry to provide shutdown protection only. This monitoring system was replaced with a coordinated series of printed circuit cards, each of which contains all the electronics to service one sensor and provide performance trend information, fault detection and isolation information, and shutdown protection. Finally, a review of sensor and instrumentation problems is presented, and the requirement for sensors with built-in signal conditioning and provisions for in situ calibration is discussed.

  17. Shared Skies Partnership: A Dual-Site All-Sky Live Remote Observing Initiative for Research and Education

    NASA Astrophysics Data System (ADS)

    Kielkopf, John F.; Hart, R.; Carter, B.; Collins, K. A.; Brown, C.; Hay, J.; Hons, A.; Marsden, S.

    2014-01-01

    The University of Southern Queensland's Mt. Kent Observatory in Queensland, Australia, and the University of Louisville's Moore Observatory in Kentucky, USA, are collaborating in the development of live remote observing for research, student training, and education. With a focus on flexible operation assisted by semi-autonomous controllers, rather than completely robotic data acquisition, the partnership provides interactive hands-on experience to students at all levels, optimized performance based on real-time observations, and flexible scheduling for transient events and targets of opportunity. Two sites on opposites sides of the globe cover the entire sky, and for equatorial regions allow nearly continuous coverage. The facilites include 0.5-m corrected Dall-Kirkham (CDK) telescopes at both sites, a 0.6 m Ritchie-Chretien telescope at Moore, and a new Nasmyth design 0.7-meter CDK at Mt. Kent instrumented for milli-magnitude precision photometry and wide field imaging, with spectrographs under development. We will describe the operational and data acquisition software, recent research results, and how remote access is being made available to students and observers.

  18. Introduction: Reengaging with instruments.

    PubMed

    Taub, Liba

    2011-12-01

    Over the past twenty years or so, historians of science have become increasingly sensitized to issues involved in studying and interpreting scientific and medical instruments. The contributors to this Focus section are historians of science who have worked closely with museum objects and collections, specifically instruments used in scientific and medical contexts. Such close engagement by historians of science is somewhat rare, provoking distinctive questions as to how we define and understand instruments, opening up issues regarding the value of broken or incomplete objects, and raising concerns about which scientific and medical artifacts are displayed and interpreted in museums and in what manner. It is hoped that these essays point historians of science in new directions for reengaging with scientific objects and collections.

  19. Focus drive mechanism for the IUE scientific instrument

    NASA Technical Reports Server (NTRS)

    Devine, E. J.; Dennis, T. B., Jr.

    1977-01-01

    A compact, lightweight mechanism was developed for in-orbit adjustment of the position of the secondary mirror (focusing) of the International Ultraviolet Explored telescope. This device is a linear drive with small (.0004 in.) and highly repeatable step increments. Extremely close tolerances are also held in tilt and decentering. The unique mechanization is described with attention to the design details that contribute to positional accuracy. Lubrication, materials, thermal considerations, sealing, detenting against launch loads, and other features peculiar to flight hardware are discussed. The methods employed for mounting the low expansion quartz mirror with minimum distortion are also given.

  20. Focus on Practice-Relationships between Lessons on the Primary Instrument and Individual Practice in Conservatoire Education

    ERIC Educational Resources Information Center

    Koopman, Constantijn; Smit, Nico; de Vugt, Adri; Deneer, Paul; den Ouden, Jeannette

    2007-01-01

    This article presents the results of research into the relationships between lessons on the primary instrument and individual practice in conservatoire education. Six cases were extensively investigated through observation, questionnaires, logbooks, and interviews. Regarding the lessons on the primary instrument, we examined aims, topics,…

  1. Instrumentation progress at the Giant Magellan Telescope project

    NASA Astrophysics Data System (ADS)

    Jacoby, George H.; Bernstein, R.; Bouchez, A.; Colless, M.; Crane, Jeff; DePoy, D.; Espeland, B.; Hare, Tyson; Jaffe, D.; Lawrence, J.; Marshall, J.; McGregor, P.; Shectman, Stephen; Sharp, R.; Szentgyorgyi, A.; Uomoto, Alan; Walls, B.

    2016-08-01

    Instrument development for the 24m Giant Magellan Telescope (GMT) is described: current activities, progress, status, and schedule. One instrument team has completed its preliminary design and is currently beginning its final design (GCLEF, an optical 350-950 nm, high-resolution and precision radial velocity echelle spectrograph). A second instrument team is in its conceptual design phase (GMACS, an optical 350-950 nm, medium resolution, 6-10 arcmin field, multi-object spectrograph). A third instrument team is midway through its preliminary design phase (GMTIFS, a near-IR YJHK diffraction-limited imager/integral-field-spectrograph), focused on risk reduction prototyping and design optimization. A fourth instrument team is currently fabricating the 5 silicon immersion gratings needed to begin its preliminary design phase (GMTNIRS, a simultaneous JHKLM high-resolution, AO-fed, echelle spectrograph). And, another instrument team is focusing on technical development and prototyping (MANIFEST, a facility robotic, multifiber feed, with a 20 arcmin field of view). In addition, a medium-field (6 arcmin, 0.06 arcsec/pix) optical imager will support telescope and AO commissioning activities, and will excel at narrow-band imaging. In the spirit of advancing synergies with other groups, the challenges of running an ELT instrument program and opportunities for cross-ELT collaborations are discussed.

  2. Focus drive mechanism for the IUE scientific instrument

    NASA Technical Reports Server (NTRS)

    Devine, E. J.; Dennis, T. B., Jr.

    1977-01-01

    A compact, lightweight mechanism was developed for in-orbit adjustment of the position of the secondary mirror (focusing) of the International Ultraviolet Explorer telescope. This device is a linear drive with small and highly repeatable step increments. Extremely close tolerances are also held in tilt and decentering. The unique mechanization is described with attention to the design details that contribute to positional accuracy. Lubrication, materials, thermal considerations, sealing, detenting against launch loads, and other features peculiar to flight hardware are discussed. The methods employed for mounting the low expansion quartz mirror with minimum distortion are also given. Results of qualification and acceptance testing, are included.

  3. BATMAN: a DMD-based MOS demonstrator on Galileo Telescope

    NASA Astrophysics Data System (ADS)

    Zamkotsian, Frédéric; Spanò, Paolo; Bon, William; Riva, Marco; Lanzoni, Patrick; Nicastro, Luciano; Molinari, Emilio; Cosentino, Rosario; Ghedina, Adriano; Gonzalez, Manuel; Di Marcantonio, Paolo; Coretti, Igor; Cirami, Roberto; Manetta, Marco; Zerbi, Filippo; Tresoldi, Daniela; Valenziano, Luca

    2012-09-01

    Multi-Object Spectrographs (MOS) are the major instruments for studying primary galaxies and remote and faint objects. Current object selection systems are limited and/or difficult to implement in next generation MOS for space and groundbased telescopes. A promising solution is the use of MOEMS devices such as micromirror arrays which allow the remote control of the multi-slit configuration in real time. We are developing a Digital Micromirror Device (DMD) - based spectrograph demonstrator called BATMAN. We want to access the largest FOV with the highest contrast. The selected component is a DMD chip from Texas Instruments in 2048 x 1080 mirrors format, with a pitch of 13.68μm. Our optical design is an all-reflective spectrograph design with F/4 on the DMD component. This demonstrator permits the study of key parameters such as throughput, contrast and ability to remove unwanted sources in the FOV (background, spoiler sources), PSF effect, new observational modes. This study will be conducted in the visible with possible extension in the IR. A breadboard on an optical bench, ROBIN, has been developed for a preliminary determination of these parameters. The demonstrator on the sky is then of prime importance for characterizing the actual performance of this new family of instruments, as well as investigating the operational procedures on astronomical objects. BATMAN will be placed on the Nasmyth focus of Telescopio Nazionale Galileo (TNG) during next year.

  4. Life Events and Academic Performance: Instrument Design.

    ERIC Educational Resources Information Center

    Burke, Janet; Cartwright, Noel

    In April 1987, a pilot study was undertaken to develop an instrument designed to assess the effects of life events on undergraduate students' academic performance. Focus was on the design and construction of the instrument--the Life Events and Academic Performance Questionnaire (LEAPQ). Subjects were 75 male and 75 female undergraduates at a large…

  5. Spanish participation in the development of HARMONI, the first light integral field spectrograph for the E-ELT.

    NASA Astrophysics Data System (ADS)

    García-Lorenzo, B.; HARMONI Consortium

    2015-05-01

    HARMONI is the visible and near infrared integral field spectrograph (IFS) selected as a first-light instrument for the European Extremely Large Telescope (E-ELT). With four spatial scales and a range of spectral resolving powers, astronomers will optimally configure the instrument to overtake a wide range of scientific programs and to address many of the E-ELT science cases. The Centro de Astrobiología del CSIC/INTA (CAB-CSIC) and the Instituto de Astrofísica de Canarias (IAC) form part of the international consortium developing HARMONI, participation that will constitute an unique scientific opportunity for the Spanish astronomical community, allowing the access to the E-ELT as soon as it were operative via the guaranteed time. We describe here the instrument and its capabilities with special attention to the Spanish contribution to HARMONI. At the current stage of the project, HARMONI design is being revised due to significant modifications of the Nasmyth platform affecting the interface with HARMONI.

  6. Gender and Instrument Associations, Stereotypes, and Stratification: A Literature Review

    ERIC Educational Resources Information Center

    Wych, Gina M. F.

    2012-01-01

    This literature review examines and synthesizes 30 years of research into the relationship between gender and musical instruments. Specifically, the review focuses on how this relationship affects instrument selection by grade school students entering a school music program. Topics include the gender typing of musical instruments, instrument…

  7. Development of the fibres of MOONS

    NASA Astrophysics Data System (ADS)

    Guinouard, Isabelle; Lee, David; Schnetler, Hermine; Taylor, William; Amans, Jean-Philippe; Montgomery, David; Oliva, Ernesto

    2014-07-01

    MOONS will exploit the full 500 square arcmin field of view offered by the Nasmyth focus of the Very Large Telescope and will be equipped with two identical triple arm cryogenic spectrographs covering the wavelength range 0.8 - 1.8 μm, with a multiplex capability of approximately 1000 fibres. Each triple arm spectrograph will produce spectra for half of the targets simultaneously. The system will have both a medium resolution (R~4000-6000) mode and a high resolution (R~20000) mode. The fibres are used to pick off each sub field of 1.05 arcseconds and are used to transport the light from the instrument focal plane to the two spectrographs. Each fibre has a microlens to focus the beam into the fibre at a relative fast focal ratio of F/3.65 to reduce the Focal Ratio Degradation (FRD). This paper presents the overall design of the fibre system and describes the specific developments required to optimise its performance. The design of the fibre input optics, the choice of the fibre connector, and the layout of the slit end are described. The results of preliminary tests to measure the effect of twisting on the FRD performance of prototype fibres are also discussed.

  8. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  9. Line-Focused Optical Excitation of Parallel Acoustic Focused Sample Streams for High Volumetric and Analytical Rate Flow Cytometry.

    PubMed

    Kalb, Daniel M; Fencl, Frank A; Woods, Travis A; Swanson, August; Maestas, Gian C; Juárez, Jaime J; Edwards, Bruce S; Shreve, Andrew P; Graves, Steven W

    2017-09-19

    Flow cytometry provides highly sensitive multiparameter analysis of cells and particles but has been largely limited to the use of a single focused sample stream. This limits the analytical rate to ∼50K particles/s and the volumetric rate to ∼250 μL/min. Despite the analytical prowess of flow cytometry, there are applications where these rates are insufficient, such as rare cell analysis in high cellular backgrounds (e.g., circulating tumor cells and fetal cells in maternal blood), detection of cells/particles in large dilute samples (e.g., water quality, urine analysis), or high-throughput screening applications. Here we report a highly parallel acoustic flow cytometer that uses an acoustic standing wave to focus particles into 16 parallel analysis points across a 2.3 mm wide optical flow cell. A line-focused laser and wide-field collection optics are used to excite and collect the fluorescence emission of these parallel streams onto a high-speed camera for analysis. With this instrument format and fluorescent microsphere standards, we obtain analysis rates of 100K/s and flow rates of 10 mL/min, while maintaining optical performance comparable to that of a commercial flow cytometer. The results with our initial prototype instrument demonstrate that the integration of key parallelizable components, including the line-focused laser, particle focusing using multinode acoustic standing waves, and a spatially arrayed detector, can increase analytical and volumetric throughputs by orders of magnitude in a compact, simple, and cost-effective platform. Such instruments will be of great value to applications in need of high-throughput yet sensitive flow cytometry analysis.

  10. The WEAVE focus translation system: from design to construction

    NASA Astrophysics Data System (ADS)

    Canchado, Manuel; Romero, Antonio; Maroto, Óscar; Tomas, Albert; Martín-Nuño, Carlos; Casalta, Joan Manel; Prida, Joaquín.; L. Aguerri, J. Alfonso; Herreros, José Miguel; Delgado, José Miguel; Burgal, José Alonso; Abrams, Don Carlos; Dee, Kevin; Dalton, Gavin; Bonifacio, Piercarlo; Trager, Scott C.; Vallenari, Antonella

    2016-07-01

    WEAVE is a new wide-field spectroscopy facility proposed for the prime focus of the 4.2m William Herschel Telescope (WHT), placed in La Palma, Canary Islands, Spain. To allow for the compensation of the effects of temperature-induced and gravity-induced image degradation, the WEAVE prime focus assembly will be translated along the telescope optical axis. The assembly comprises the prime focus corrector with integrated ADC, a central mount for the corrector, an instrument rotator and a twin-focal-plane fibre positioner. Translation is accomplished through the use of a set of purpose-built actuators; collectively referred to as the Focus Translation System (FTS), formed by four independently-controlled Focus Translation Units (FTUs), eight vanes connecting the FTUs to a central can, and a central can hosting WEAVE Instrument. Each FTU is capable of providing a maximum stroke of +/-4mm with sufficient, combined force to move the five-tonne assembly with a positional accuracy of +/-20μm at a resolution of 5μm. The coordinated movement of the four FTUs allows +/-3mm WEAVE focus adjustment in the optical axis and +/-0.015° tilt correction in one axis. The control of the FTS is accomplished through a PLC-based subsystem that receives positional demands from the higher-level Instrument Control System. SENER has been responsible for designing, manufacturing and testing the FTS and the equipment required to manipulate and store the FTS together with the instrument. This manuscript describes the final design of the FTS along with the analyses and simulations that were performed, discusses the manufacturing procedures and the results of early verification prior to integration with the telescope. The plans for mounting the whole system on the telescope are also discussed.

  11. Evaluating nursing administration instruments.

    PubMed

    Huber, D L; Maas, M; McCloskey, J; Scherb, C A; Goode, C J; Watson, C

    2000-05-01

    To identify and evaluate available measures that can be used to examine the effects of management innovations in five important areas: autonomy, conflict, job satisfaction, leadership, and organizational climate. Management interventions target the context in which care is delivered and through which evidence for practice diffuses. These innovations need to be evaluated for their effects on desired outcomes. However, busy nurses may not have the time to locate, evaluate, and select instruments to measure expected nursing administration outcomes without research-based guidance. Multiple and complex important contextual variables need psychometrically sound and easy-to-use measurement instruments identified for use in both practice and research. An expert focus group consensus methodology was used in this evaluation research to review available instruments in the five areas and evaluate which of these instruments are psychometrically sound and easy to use in the practice setting. The result is a portfolio of measures, clustered by concept and displayed on a spreadsheet. Retrieval information is provided. The portfolio includes the expert consensus judgment as well as useful descriptive information. The research reported here identifies psychometrically sound and easy-to-use instruments for measuring five key variables to be included in a portfolio. The results of this study can be used as a beginning for saving time in instrument selection and as an aid for determining the best instrument for measuring outcomes from a clinical or management intervention.

  12. Eponymous Instruments in Orthopaedic Surgery

    PubMed Central

    Buraimoh, M. Ayodele; Liu, Jane Z.; Sundberg, Stephen B.; Mott, Michael P.

    2017-01-01

    Abstract Every day surgeons call for instruments devised by surgeon trailblazers. This article aims to give an account of commonly used eponymous instruments in orthopaedic surgery, focusing on the original intent of their designers in order to inform how we use them today. We searched PubMed, the archives of longstanding medical journals, Google, the Internet Archive, and the HathiTrust Digital Library for information regarding the inventors and the developments of 7 instruments: the Steinmann pin, Bovie electrocautery, Metzenbaum scissors, Freer elevator, Cobb periosteal elevator, Kocher clamp, and Verbrugge bone holding forceps. A combination of ingenuity, necessity, circumstance and collaboration produced the inventions of the surgical tools numbered in our review. In some cases, surgical instruments were improvements of already existing technologies. The indications and applications of the orthopaedic devices have changed little. Meanwhile, instruments originally developed for other specialties have been adapted for our use. Although some argue for a transition from eponymous to descriptive terms in medicine, there is value in recognizing those who revolutionized surgical techniques and instrumentation. Through history, we have an opportunity to be inspired and to better understand our tools. PMID:28852360

  13. Latest NASA Instrument Cost Model (NICM): Version VI

    NASA Technical Reports Server (NTRS)

    Mrozinski, Joe; Habib-Agahi, Hamid; Fox, George; Ball, Gary

    2014-01-01

    The NASA Instrument Cost Model, NICM, is a suite of tools which allow for probabilistic cost estimation of NASA's space-flight instruments at both the system and subsystem level. NICM also includes the ability to perform cost by analogy as well as joint confidence level (JCL) analysis. The latest version of NICM, Version VI, was released in Spring 2014. This paper will focus on the new features released with NICM VI, which include: 1) The NICM-E cost estimating relationship, which is applicable for instruments flying on Explorer-like class missions; 2) The new cluster analysis ability which, alongside the results of the parametric cost estimation for the user's instrument, also provides a visualization of the user's instrument's similarity to previously flown instruments; and 3) includes new cost estimating relationships for in-situ instruments.

  14. Instrument and method for focusing x rays, gamma rays, and neutrons

    DOEpatents

    Smither, R.K.

    1981-04-20

    A crystal diffraction instrument is described which has an improved crystalline structure having a face for receiving a beam of photons or neutrons and diffraction planar spacing along that face with the spacing increasing progressively along the face to provide a decreasing Bragg angle and thereby increasing the usable area and acceptance angle. The increased planar spacing is provided by the use of a temperature differential across the crystalline structure, by assembling a plurality of crystalline structure with different compositions, by an individual crystalline structure with a varying composition and thereby a changing planar spacing along its face, and by combinations of these techniques.

  15. The Magellan Telescopes

    NASA Astrophysics Data System (ADS)

    Shectman, Stephen A.; Johns, Matthew

    2003-02-01

    Commissioning of the two 6.5-meter Magellan telescopes is nearing completion at the Las Campanas Observatory in Chile. The Magellan 1 primary mirror was successfully aluminized at Las Campanas in August 2000. Science operations at Magellan 1 began in February 2001. The second Nasmyth focus on Magellan 1 went into operation in September 2001. Science operations on Magellan 2 are scheduled to begin shortly. The ability to deliver high-quality images is maintained at all times by the simultaneous operation of the primary mirror support system, the primary mirror thermal control system, and a real-time active optics system, based on a Shack-Hartmann image analyzer. Residual aberrations in the delivered image (including focus) are typically 0.10-0.15" fwhm, and real images as good as 0.25" fwhm have been obtained at optical wavelengths. The mount points reliably to 2" rms over the entire sky, using a pointing model which is stable from year to year. The tracking error under typical wind conditions is better than 0.03" rms, although some degradation is observed under high wind conditions when the dome is pointed in an unfavorable direction. Instruments used at Magellan 1 during the first year of operation include two spectrographs previously used at other telescopes (B&C, LDSS-2), a mid-infrared imager (MIRAC) and an optical imager (MAGIC, the first Magellan-specific facility instrument). Two facility spectrographs are scheduled to be installed shortly: IMACS, a wide-field spectrograph, and MIKE, a double echelle spectrograph.

  16. Management Approach for Earth Venture Instrument

    NASA Technical Reports Server (NTRS)

    Hope, Diane L.; Dutta, Sanghamitra

    2013-01-01

    The Earth Venture Instrument (EVI) element of the Earth Venture Program calls for developing instruments for participation on a NASA-arranged spaceflight mission of opportunity to conduct innovative, integrated, hypothesis or scientific question-driven approaches to pressing Earth system science issues. This paper discusses the EVI element and the management approach being used to manage both an instrument development activity as well as the host accommodations activity. In particular the focus will be on the approach being used for the first EVI (EVI-1) selected instrument, Tropospheric Emissions: Monitoring of Pollution (TEMPO), which will be hosted on a commercial GEO satellite and some of the challenges encountered to date and corresponding mitigations that are associated with the management structure for the TEMPO Mission and the architecture of EVI.

  17. Guidelines for Successful Use and Communication of Instrument Heritage in Early Mission Development with a Focus on Spectrometers

    NASA Technical Reports Server (NTRS)

    Baker, Elizabeth E.

    2012-01-01

    Heritage is important for both cost and risk related issues and as such, it is heavily discussed in NASA proposal evaluations. If used and communicated efficiently, heritage can lower both the perception of risk and the associated costs. Definitions of heritage vary between engineering, cost, and scientific communities, but when applied appropriately, heritage provides a benefit to the proposed mission. By making an instrument at least once before, the cost of producing it again can be reduced. The time and effort needed to develop the instrument concept and test the product represent an expense that can be lowered through the use of a previously built and developed instrument. This same thought can be applied when using a flight spare or build-to-print model of the heritage instrument. The lowered perception of risk is a result of the confidence gained in the instrument through successful use in the target environment. This is extremely important in early mission development to the evaluation board. This analysis will use JPL-managed proposals from 2003 to 2011, including Discovery, New Frontiers, and Mars Scout missions. Through the examination of these proposals and their associated debriefs, a set of guidelines have been created for successful use and communication of instrument heritage in early mission development

  18. 2017 Marine Hydrokinetic Instrumentation Workshop Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driscoll, Frederick R; Mauer, Erik; Rieks, Jeff

    The third Marine Hydrokinetic Instrumentation Workshop was held at Florida Atlantic University's Sea Tech Campus in Dania Beach, Florida, from February 28 to March 1, 2017. The workshop brought together 37 experts in marine energy measurement, testing, and technology development to present and discuss the instrumentation and data-processing needs of the marine energy industry. The workshop was comprised of a plenary session followed by two focused breakout sessions. The half-day plenary session reviewed findings from prior instrumentation workshops, presented research activities that aim to fill previously identified gaps, and had industry experts present the state of the marine energy measurementmore » technologies. This report provides further detail on the workshop, objectives, and findings.« less

  19. Instrumentalism in the Field of Music Education? Are We All Humanists?

    ERIC Educational Resources Information Center

    Varkoy, Oivind

    2007-01-01

    Oivind Varkoy discusses instrumentalism as a trend in educational politics and pedagogical thinking. Instrumentalism implies looking upon both school subjects and humans as instruments, as tools or means for reaching another goal or end. The discussion is related to philosophy of music education by focusing on aspects of philosophies of humankind,…

  20. Understanding the interplay of cancer patients' instrumental concerns and emotions.

    PubMed

    Brandes, Kim; van der Goot, Margot J; Smit, Edith G; van Weert, Julia C M; Linn, Annemiek J

    2017-05-01

    1) to assess patients' descriptions of concerns, and 2) to inform a conceptual framework in which the impact of the nature of concerns on doctor-patient communication is specified. Six focus groups were conducted with 39 cancer patients and survivors. In these focus groups participants were asked to describe their concerns during and after their illness. Concerns were described as instrumental concerns (e.g., receiving insufficient information) and emotions (e.g., sadness). Patients frequently explained their concerns as an interplay of instrumental concerns and emotions. Examples of the interplay were "receiving incorrect information" and "frustration", and "difficulties with searching, finding and judging of information" and "fear". Instrumental concerns need to be taken into account in the operationalization of concerns in research. Based on the interplay, the conceptual framework suggests that patients can express instrumental concerns as emotions and emotions as instrumental concerns. Consequently, providers can respond with instrumental and emotional communication when patients express an interplay of concerns. The results of this study can be used to support providers in recognizing concerns that are expressed by patients in consultations. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Automatic Focus Adjustment of a Microscope

    NASA Technical Reports Server (NTRS)

    Huntsberger, Terrance

    2005-01-01

    AUTOFOCUS is a computer program for use in a control system that automatically adjusts the position of an instrument arm that carries a microscope equipped with an electronic camera. In the original intended application of AUTOFOCUS, the imaging microscope would be carried by an exploratory robotic vehicle on a remote planet, but AUTOFOCUS could also be adapted to similar applications on Earth. Initially control software other than AUTOFOCUS brings the microscope to a position above a target to be imaged. Then the instrument arm is moved to lower the microscope toward the target: nominally, the target is approached from a starting distance of 3 cm in 10 steps of 3 mm each. After each step, the image in the camera is subjected to a wavelet transform, which is used to evaluate the texture in the image at multiple scales to determine whether and by how much the microscope is approaching focus. A focus measure is derived from the transform and used to guide the arm to bring the microscope to the focal height. When the analysis reveals that the microscope is in focus, image data are recorded and transmitted.

  2. Teaching Historical Contextualization: The Construction of a Reliable Observation Instrument

    ERIC Educational Resources Information Center

    Huijgen, Tim; van de Grift, Wim; van Boxtel, Carla; Holthuis, Paul

    2017-01-01

    Since the 1970s, many observation instruments have been constructed to map teachers' general pedagogic competencies. However, few of these instruments focus on teachers' subject-specific competencies. This study presents the development of the "Framework for Analyzing the Teaching of Historical Contextualization" (FAT-HC). This…

  3. Evaluation of the FOCUS (Feedback on Counseling Using Simulation) Instrument for Assessment of Client-Centered Nutrition Counseling Behaviors

    ERIC Educational Resources Information Center

    Henry, Beverly W.; Smith, Thomas J.

    2010-01-01

    Objective: To develop an instrument to assess client-centered counseling behaviors (skills) of student-counselors in a standardized patient (SP) exercise. Methods: Descriptive study of the accuracy and utility of a newly developed counseling evaluation instrument. Study participants included 11 female student-counselors at a Midwestern…

  4. Testing Instrument for Flight-Simulator Displays

    NASA Technical Reports Server (NTRS)

    Haines, Richard F.

    1987-01-01

    Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.

  5. Dermatologic Surgical Instruments: A History and Review.

    PubMed

    Gandhi, Sumul A; Kampp, Jeremy T

    2017-01-01

    Dermatologic surgery requires precision and accuracy given the delicate nature of procedures performed. The use of the most appropriate instrument for each action helps optimize both functionality and cosmetic outcome. To review the history of surgical instruments used in dermatology, with a focus on mechanism and evolution to the instruments that are used in current practice. A comprehensive literature search was conducted via textbook and journal research for historic references while review of current references was conducted online using multiple search engines and PubMed. There are a number of articles that review instruments in dermatology, but this article adds a unique perspective in classifying their evolution, while also presenting them as levers that serve to increase human dexterity during the course of surgery. Surgical instruments allow fine manipulation of tissue, which in turn produces optimal outcomes. Surgical tools have been around since the dawn of man, and their evolution parallels the extent to which human civilization has specialized over time. This article describes the evolution of instruments from the general surgical armamentaria to the specialized tools that are used today.

  6. Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

    NASA Technical Reports Server (NTRS)

    Aronstein, David L.; Smith, J. Scott; Zielinski, Thomas P.; Telfer, Randal; Tournois, Severine C.; Moore, Dustin B.; Fienup, James R.

    2016-01-01

    The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES). In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing (also known as phase retrieval), and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) plate scale measurements made using a Pseudo-Nonredundant Mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated andor rotated across the exit pupil of the system.Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the

  7. Focusing on What Counts: Using Exploratory Focus Groups to Enhance the Development of an Electronic Survey in a Mixed-Methods Research Design

    ERIC Educational Resources Information Center

    Galliott, Natal'ya; Graham, Linda J.

    2016-01-01

    This paper illustrates the use of exploratory focus groups to inform the development of a survey instrument in a sequential phase mixed-methods study investigating differences in secondary students' career choice capability. Five focus groups were conducted with 23 Year 10 students in the state of New South Wales, Australia. Analysis of the focus…

  8. Latest trends in craniomaxillofacial surgical instrumentation.

    PubMed

    Yim, Michael; Demke, Joshua

    2012-08-01

    To review the past year's literature regarding recent innovations in surgical instrumentation for craniomaxillofacial surgery. Current advances in surgical instrumentation have led to many improvements in the field, allowing greater visualization and precision both before and during procedures. One of the common goals is to achieve excellent outcomes with minimal complications, while at the same time minimizing invasiveness of surgery. Highlighted innovations include greater capacities for acquisition of data, leading to improved imaging modalities and expansion of computer-assisted surgical techniques; continued developments in biomaterials used in various reconstructions; and novel uses of bone cutting and bone fixation instrumentation. Technology in the field of craniomaxillofacial surgery is developing rapidly, leading to novel instrumentation being utilized across a broad spectrum of areas. Published data have been encouraging to date, indicating an ever increasing adaptation of these innovations in clinical practice. Future efforts need to focus on cost-benefit analysis and constructing larger-scale studies to better understand effectiveness and patient outcomes.

  9. Using Instruments for Tactical Assessment in Physical Education and Extra-Curricular Sports

    ERIC Educational Resources Information Center

    Arias-Estero, José; Castejón, Francisco

    2014-01-01

    The aim was to analyse the features concerning the applicational purpose and strategy of the most common instruments used to assess game tactics both in Physical Education (PE) and in extra-curricular sport contexts. The review focused on two instruments: the Game Performance Assessment Instrument (GPAI) and the Team Sport Assessment Procedure…

  10. A 2.5m astronomical telescope project

    NASA Astrophysics Data System (ADS)

    Phaichith, Oudomsanith

    2008-07-01

    The paper reports a recently started project for a 2,5 meter diameter robotic telescope dedicated to astronomy and education for the University of Moscow's Sternberg Institute. As a prime contractor Sagem Defense Securite's REOSC department will take on the program design as well as the production of the optical components. The project includes the Alt-Az mount, the dome and its cooling and air stabilization system, the weather station, the high-resolution camera and realization, transport and installation on-site at the Kislovodsk solar station located in the Caucasus mountains as well as the initial training for the operators. The telescope will provide a wide field of view of 40 arcmin at the Cassegrain F/8 focus. An escapable and rotating tertiary mirror will allow to direct the light to the two Nasmyth foci and two student ports located at 90° from the Nasmyth foci. A 4k x 4k CCD camera cryogenically cooled to 140 K will be provided as a first light camera. All will be delivered by end 2009. Remotely controlled via the internet, the telescope will allow Russia to train doctors in astronomy, participate in international research projects and draw up the future specifications of a larger and more advanced telescope.

  11. An overview of instrumentation for the Large Binocular Telescope

    NASA Astrophysics Data System (ADS)

    Wagner, R. Mark

    2006-06-01

    An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' × 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 × 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.

  12. An overview of instrumentation for the Large Binocular Telescope

    NASA Astrophysics Data System (ADS)

    Wagner, R. Mark

    2008-07-01

    An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' × 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6 field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0.5' × 0.5') imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.

  13. Instrumental resolution as a function of scattering angle and wavelength as exemplified for the POWGEN instrument

    PubMed Central

    Jacobs, Philipp; Houben, Andreas; Schweika, Werner; Tchougréeff, Andrei L.; Dronskowski, Richard

    2017-01-01

    The method of angular- and wavelength-dispersive (e.g. two-dimensional) Rietveld refinement is a new and emerging tool for the analysis of neutron diffraction data measured at time-of-flight instruments with large area detectors. Following the approach for one-dimensional refinements (using either scattering angle or time of flight), the first step at each beam time cycle is the calibration of the instrument including the determination of instrumental contributions to the peak shape variation to be expected for diffraction patterns measured by the users. The aim of this work is to provide the users with calibration files and – for the later Rietveld refinement of the measured data – with an instrumental resolution file (IRF). This article will elaborate on the necessary steps to generate such an IRF for the angular- and wavelength-dispersive case, exemplified for the POWGEN instrument. A dataset measured on a standard diamond sample is used to extract the profile function in the two-dimensional case. It is found that the variation of reflection width with 2θ and λ can be expressed by the standard equation used for evaluating the instrumental resolution, which yields a substantially more fundamental approach to the parameterization of the instrumental contribution to the peak shape. Geometrical considerations of the POWGEN instrument and sample effects lead to values for Δθ, Δt and ΔL that yield a very good match to the extracted FWHM values. In a final step the refinement results are compared with the one-dimensional, i.e. diffraction-focused, case. PMID:28656041

  14. Instrumentation of the Maumee River Crossing.

    DOT National Transportation Integrated Search

    2012-03-01

    This project has focused on the instrumentation, monitoring and testing of the main span unit of the VGCS, one of Ohio's first long-span, cable-stayed bridges and one of only a few dozen such bridges in service in the nation. This effort looked at fi...

  15. Hormone Purification by Isoelectric Focusing

    NASA Technical Reports Server (NTRS)

    Bier, M.

    1985-01-01

    Various ground-based research approaches are being applied to a more definitive evaluation of the natures and degrees of electroosmosis effects on the separation capabilities of the Isoelectric Focusing (IEF) process. A primary instrumental system for this work involves rotationally stabilized, horizontal electrophoretic columns specially adapted for the IEF process. Representative adaptations include segmentation, baffles/screens, and surface coatings. Comparative performance and development testing are pursued against the type of column or cell established as an engineering model. Previously developed computer simulation capabilities are used to predict low-gravity behavior patterns and performance for IEF apparatus geometries of direct project interest. Three existing mathematical models plus potential new routines for particular aspects of simulating instrument fluid patterns with varied wall electroosmosis influences are being exercised.

  16. Gyroscopic Instruments for Instrument Flying

    NASA Technical Reports Server (NTRS)

    Brombacher, W G; Trent, W C

    1938-01-01

    The gyroscopic instruments commonly used in instrument flying in the United States are the turn indicator, the directional gyro, the gyromagnetic compass, the gyroscopic horizon, and the automatic pilot. These instruments are described. Performance data and the method of testing in the laboratory are given for the turn indicator, the directional gyro, and the gyroscopic horizon. Apparatus for driving the instruments is discussed.

  17. Monte Carlo simulations of neutron-scattering instruments using McStas

    NASA Astrophysics Data System (ADS)

    Nielsen, K.; Lefmann, K.

    2000-06-01

    Monte Carlo simulations have become an essential tool for improving the performance of neutron-scattering instruments, since the level of sophistication in the design of instruments is defeating purely analytical methods. The program McStas, being developed at Risø National Laboratory, includes an extension language that makes it easy to adapt it to the particular requirements of individual instruments, and thus provides a powerful and flexible tool for constructing such simulations. McStas has been successfully applied in such areas as neutron guide design, flux optimization, non-Gaussian resolution functions of triple-axis spectrometers, and time-focusing in time-of-flight instruments.

  18. An overview of instrumentation for the Large Binocular Telescope

    NASA Astrophysics Data System (ADS)

    Wagner, R. Mark

    2010-07-01

    An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27 × 27) mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6 field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4 × 4) imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0.5 × 0.5) imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support. Over the past two years the LBC and the first LUCIFER instrument have been brought into routine scientific operation and MODS1 commissioning is set to begin in the fall of 2010.

  19. Reflections on John Monaghan's "Computer Algebra, Instrumentation, and the Anthropological Approach"

    ERIC Educational Resources Information Center

    Blume, Glen

    2007-01-01

    Reactions to John Monaghan's "Computer Algebra, Instrumentation and the Anthropological Approach" focus on a variety of issues related to the ergonomic approach (instrumentation) and anthropological approach to mathematical activity and practice. These include uses of the term technique; several possibilities for integration of the two approaches;…

  20. An overview of instrumentation for the Large Binocular Telescope

    NASA Astrophysics Data System (ADS)

    Wagner, R. Mark

    2004-09-01

    An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27'x 27') UB/VRI optimized mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6\\arcmin\\ field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4'x 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 x 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench beam combiner with visible and near-infrared imagers utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC/NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.

  1. The Focusing Optics X-ray Solar Imager (FOXSI): Instrument and First Flight

    NASA Astrophysics Data System (ADS)

    Glesener, Lindsay; Christe, S.; Ishikawa, S.; Ramsey, B.; Takahashi, T.; Saito, S.; Lin, R. P.; Krucker, S.; FOXSI Team

    2013-04-01

    Understanding electron acceleration in solar flares requires hard X-ray studies with greater sensitivity and dynamic range than are available with current solar hard X-ray observers (i.e. the RHESSI spacecraft). Both these capabilities can be advanced by the use of direct focusing optics instead of the indirect Fourier methods of current and previous generations. The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload demonstrates the feasibility and usefulness of hard X-ray focusing optics for solar observation. FOXSI flew for the first time on 2012 November 2, producing images and spectra of a microflare and performing a search for nonthermal X-rays from the quiet Sun. Such measurements are important for characterizing the impact of small "nanoflares" on the solar coronal heating problem. A spaceborne solar observer featuring similar optics could make detailed observations of hard X-rays from flare-accelerated electrons, identifying and characterizing particle acceleration sites and mapping out paths of energetic electrons as they leave these sites and propagate throughout the solar corona. Solar observations from NuSTAR are also expected to be an important step in this direction.

  2. Gender, Expressiveness, Instrumentality, and Group Social Environment as Predictors of Self-Disclosure.

    ERIC Educational Resources Information Center

    Kunkle, Suzanne; Gerrity, Deborah A.

    1997-01-01

    Explores the relationship among self-disclosure, discloser gender, expressiveness, instrumentality, and group social environment in personal growth classes. Focuses on individual personality and group social environment characteristics in an established group. Results indicate that expressiveness, instrumentality, and the relationship dimension of…

  3. Instructional Interactions of Kindergarten Mathematics Classrooms: Validating a Direct Observation Instrument

    ERIC Educational Resources Information Center

    Doabler, Christian; Smolkowski, Keith; Fien, Hank; Kosty, Derek B.; Cary, Mari Strand

    2010-01-01

    In this paper, the authors report research focused directly on the validation of the Coding of Academic Teacher-Student interactions (CATS) direct observation instrument. They use classroom information gathered by the CATS instrument to better understand the potential mediating variables hypothesized to influence student achievement. Their study's…

  4. The Design of Ocean Turbulence Measurement with a Free Fall Vertical Profiler

    NASA Astrophysics Data System (ADS)

    Luan, Xin; Xin, Jia; Zhu, Tieyi; Yang, Hua; Teng, Yuru; Song, Dalei

    2018-03-01

    The newly designed instrument Free Fall Vertical Profiler (FFVP) developed by Ocean University of China (OUC) had been deployed in the Western Pacific in March 08, 2017 and succeed to collect turbulence signals about 350-m-deep water. According to the requirements of turbulence measurement, the mechanical design was developed for turbulence platform to achieve stability and good flow tracking. By analysing the Heading, Pitch and Roll, the results suggested that the platform satisfies the requirements of stability. The power spectrum of the cleaned shear signals using the noise correction algorithm match well with the theoretical Nasmyth spectrum and the rate of turbulence dissipation are approximately 10-8 W/kg. In general, the FFVP was rationally designed and provided a good measurement platform for turbulence observation.

  5. Instrumentation Cables Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muna, Alice Baca; LaFleur, Chris Bensdotter

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteriamore » 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended

  6. Nonlinear modelling in time domain numerical analysis of stringed instrument dynamics

    NASA Astrophysics Data System (ADS)

    Bielski, Paweł; Kujawa, Marcin

    2017-03-01

    Musical instruments are very various in terms of sound quality with their timbre shaped by materials and geometry. Materials' impact is commonly treated as dominant one by musicians, while it is unclear whether it is true or not. The research proposed in the study focuses on determining influence of both these factors on sound quality based on their impact on harmonic composition. Numerical approach has been chosen to allowed independent manipulation of geometrical and material parameters as opposed to experimental study subjected to natural randomness of instrument construction. Distinctive element of this research is precise modelling of whole instrument and treating it as one big vibrating system instead of performing modal analysis on an isolated part. Finite elements model of a stringed instrument has been built and a series of nonlinear time-domain dynamic analyses were executed to obtain displacement signals and perform subsequent spectral analysis. Precision of computations seems sufficient to determine the influence of instrument's macroscopic mechanical parameters on timbre. Further research should focus on implementation of acoustic medium in attempt to include dissipation and synchronization mechanisms. Outside the musical field this kind of research could be potentially useful in noise reduction problems.

  7. Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

    NASA Technical Reports Server (NTRS)

    Aronstein, David L.; Smith, J. Scott; Zielinski, Thomas P.; Telfer, Randal; Tournois, Severine C.; Moore, Dustin B.; Fienup, James R.

    2016-01-01

    The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES) test chamber. In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing, and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) F-number and pupil-distortion measurements made using a pseudo-nonredundant mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated and/or rotated across the exit pupil of the system. Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish

  8. Psychometric testing of the clinical nurse leader staff satisfaction instrument.

    PubMed

    Spiva, LeeAnna; Hart, Patricia L; Wesley, Mary Lou; Gallagher, Erin; McVay, Frank; Waggoner, Jessica; Jarrell, Nicole; Threatt, Jamie L

    2014-01-01

    Patient care is changing rapidly with increased complexity of care, patient volumes, and financial constraints with rising health care costs and limited reimbursements. In response, the clinical nurse leader (CNL) role was developed. No appropriate instrument exists to measure staff satisfaction with the CNL role. This study describes the development and testing of an instrument designed to measure staff satisfaction with implementation of the CNL role. The psychometric properties and factor structure of the Clinical Nurse Leader Staff Satisfaction (CNLSS) instrument was examined. A 2-factor solution was discovered for the CNLSS. Cronbach's alpha coefficients were acceptable for the subscales and instrument. The CNLSS is a valid and reliable instrument. Future research should focus on establishing test-retest reliability and construct validity.

  9. Avoidance-based human Pavlovian-to-instrumental transfer

    PubMed Central

    Lewis, Andrea H.; Niznikiewicz, Michael A.; Delamater, Andrew R.; Delgado, Mauricio R.

    2013-01-01

    The Pavlovian-to-instrumental transfer (PIT) paradigm probes the influence of Pavlovian cues over instrumentally learned behavior. The paradigm has been used extensively to probe basic cognitive and motivational processes in studies of animal learning but, more recently, PIT and its underlying neural basis have been extended to investigations in humans. These initial neuroimaging studies of PIT have focused on the influence of appetitively conditioned stimuli on instrumental responses maintained by positive reinforcement, and highlight the involvement of the striatum. In the current study, we sought to understand the neural correlates of PIT in an aversive Pavlovian learning situation when instrumental responding was maintained through negative reinforcement. Participants exhibited specific PIT, wherein selective increases in instrumental responding to conditioned stimuli occurred when the stimulus signaled a specific aversive outcome whose omission negatively reinforced the instrumental response. Additionally, a general PIT effect was observed such that when a stimulus was associated with a different aversive outcome than was used to negatively reinforce instrumental behavior, the presence of that stimulus caused a non-selective increase in overall instrumental responding. Both specific and general PIT behavioral effects correlated with increased activation in corticostriatal circuitry, particularly in the striatum, a region involved in cognitive and motivational processes. These results suggest that avoidance-based PIT utilizes a similar neural mechanism to that seen with PIT in an appetitive context, which has implications for understanding mechanisms of drug-seeking behavior during addiction and relapse. PMID:24118624

  10. Agri-Environmental Policy Measures in Israel: The Potential of Using Market-Oriented Instruments

    NASA Astrophysics Data System (ADS)

    Amdur, Liron; Bertke, Elke; Freese, Jan; Marggraf, Rainer

    2011-05-01

    This paper examines the possibilities of developing agri-environmental policy measures in Israel, focusing on market-oriented instruments. A conceptual framework for developing agri-environmental policy measures is presented, first in very broad lines (mandatory regulations, economic instruments and advisory measures) and subsequently focusing on economic instruments, and specifically, on market-oriented ones. Two criteria of choice between the measures are suggested: their contribution to improving the effectiveness of the policy; and the feasibility of their implementation. This is the framework used for analyzing agri-environmental measures in Israel. Israel currently implements a mix of mandatory regulations, economic instruments and advisory measures to promote the agri-environment. The use of additional economic instruments may improve the effectiveness of the policy. When comparing the effectiveness of various economic measures, we found that the feasibility of implementation of market-oriented instruments is greater, due to the Israeli public's preference for strengthening market orientation in the agricultural sector. Four market-oriented instruments were practiced in a pilot project conducted in an Israeli rural area. We found that in this case study, the institutional feasibility and acceptance by stakeholders were the major parameters influencing the implementation of the market-oriented instruments, whereas the instruments' contribution to enhancing the ecological or economic effectiveness were hardly considered by the stakeholders as arguments in favor of their use.

  11. Agri-environmental policy measures in Israel: the potential of using market-oriented instruments.

    PubMed

    Amdur, Liron; Bertke, Elke; Freese, Jan; Marggraf, Rainer

    2011-05-01

    This paper examines the possibilities of developing agri-environmental policy measures in Israel, focusing on market-oriented instruments. A conceptual framework for developing agri-environmental policy measures is presented, first in very broad lines (mandatory regulations, economic instruments and advisory measures) and subsequently focusing on economic instruments, and specifically, on market-oriented ones. Two criteria of choice between the measures are suggested: their contribution to improving the effectiveness of the policy; and the feasibility of their implementation. This is the framework used for analyzing agri-environmental measures in Israel. Israel currently implements a mix of mandatory regulations, economic instruments and advisory measures to promote the agri-environment. The use of additional economic instruments may improve the effectiveness of the policy. When comparing the effectiveness of various economic measures, we found that the feasibility of implementation of market-oriented instruments is greater, due to the Israeli public's preference for strengthening market orientation in the agricultural sector. Four market-oriented instruments were practiced in a pilot project conducted in an Israeli rural area. We found that in this case study, the institutional feasibility and acceptance by stakeholders were the major parameters influencing the implementation of the market-oriented instruments, whereas the instruments' contribution to enhancing the ecological or economic effectiveness were hardly considered by the stakeholders as arguments in favor of their use.

  12. Borehole survey instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharp, H.E.; Lin, J.W. III; Macha, E.S.

    1984-12-04

    A borehole survey instrument is provided having a meniscus type floating compass member with indicia thereon for indicating azimuth and inclination. A light source is disposed below the indicia for illuminating the indicia upward through the liquid through which the meniscus type floating compass member floats. A lens system is provided for focusing the image of the illuminated compass member upon a film disposed below the compass member. This arrangement permits the centering post for the compass member to be of minimum diameter consistent with rigidity requirements and permits a high angle compass member to indicate angles of inclination approachingmore » ninety degrees. A multiple light bulb light source is utilized and each light bulb is mounted in a manner which permits a single light bulb to illuminate the entire compass member. A hand-held programming and diagnostic unit is provided which may be momentarily electrically mated with the borehole survey tool to input a programmed timed delay and diagnostically test both the condition of the light bulbs utilized as the illumination source and the state of the batteries within the instrument. This hand-held programmable unit eliminates all the mechanical programming switches and permits the instrument to be completely sealed from the pressure, fluids and contaminants normally found in a well bore.« less

  13. The Conceptual Framework for the Development of a Mathematics Performance Assessment Instrument.

    ERIC Educational Resources Information Center

    Lane, Suzanne

    1993-01-01

    A conceptual framework is presented for the development of the Quantitative Understanding: Amplifying Student Achievement and Reasoning (QUASAR) Cognitive Assessment Instrument (QCAI) that focuses on the ability of middle-school students to problem solve, reason, and communicate mathematically. The instrument will provide programatic rather than…

  14. Musical Sound, Instruments, and Equipment

    NASA Astrophysics Data System (ADS)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  15. CHEOPS: status summary of the instrument development

    NASA Astrophysics Data System (ADS)

    Beck, T.; Broeg, C.; Fortier, A.; Cessa, V.; Malvasio, L.; Piazza, D.; Benz, W.; Thomas, N.; Magrin, D.; Viotto, V.; Bergomi, M.; Ragazzoni, R.; Pagano, I.; Peter, G.; Buder, M.; Plesseria, J. Y.; Steller, M.; Ottensamer, R.; Ehrenreich, D.; Van Damme, C.; Isaak, K.; Ratti, F.; Rando, N.; Ngan, I.

    2016-07-01

    CHEOPS (CHaracterizing ExOPlanets Satellite) is the first ESA Small Mission as part of the ESA Cosmic Vision program 2015-2025. The mission was formally adopted in early February 2014 with a planned launch readiness end of 2017. The mission lead is performed in a partnership between Switzerland, led by the University of Bern, and the European Space Agency with important contributions from Austria, Belgium, France, Germany, Hungary, Italy, Portugal, Spain, Sweden, and the United Kingdom. The mission is dedicated to searching for exoplanetary transits by performing ultrahigh precision photometry on bright starts already known to host planets whose mass has been already estimated through ground based observations. The instrument is an optical Ritchey-Chretien telescope of 30 cm clear aperture using a single CCD detector. The optical system is designed to image a de-focused PSF onto the focal plane with very stringent stability and straylight rejection requirements providing a FoV of 0.32 degrees full cone. The system design is adapted to meet the top-level science requirements, which ask for a photometric precision of 20ppm, in 6 hours integration time, on transit measurements of G5 dwarf stars with V-band magnitudes in the range 6≤V≤9 mag. Additionally they ask for a photometric precision of 85 ppm in 3 hours integration time of Neptune-size planets transiting K-type dwarf stars with V-band magnitudes as faint as V=12 mag. Given the demanding schedule and cost constrains, the mission relies mostly on components with flight heritage for the platform as well as for the payload components. Nevertheless, several new developments are integrated into the design as for example the telescope structure and the very low noise, high stability CCD front end electronics. The instrument and mission have gone through critical design review in fall 2015 / spring 2016. This paper describes the current instrument and mission design with a focus on the instrument. It outlines the

  16. Strategies for Successfully Teaching Students with ADD or ADHD in Instrumental Lessons

    ERIC Educational Resources Information Center

    Melago, Kathleen A.

    2014-01-01

    Teachers can easily encounter students with Attention Deficit Disorder (ADD) or Attention Deficit Hyperactivity Disorder (ADHD) in the instrumental lesson setting. Applicable to instrumental lesson settings in the public or private schools, private studios, or college studios, this article focuses on specific strategies ranging from the…

  17. The Habitat Demonstration Unit Project: A Modular Instrumentation System for a Deep Space Habitat

    NASA Technical Reports Server (NTRS)

    Rojdev, Kristina; Kennedy, Kriss J.; Yim, Hester; Williamsn, Robert M.; Hafermalz, Scott; Wagner, Raymond S.

    2011-01-01

    NASA is focused on developing human exploration capabilities in low Earth orbit (LEO), expanding to near Earth asteroids (NEA), and finally to Mars. Habitation is a crucial aspect of human exploration, and a current focus of NASA activities. The Habitation Demonstration Unit (HDU) is a project focused on developing an autonomous habitation system that enables human exploration of space by providing engineers and scientists with a test bed to develop, integrate, test, and evaluate habitation systems. A critical feature of the HDU is the instrumentation system, which monitors key subsystems within the habitat. The following paper will discuss the HDU instrumentation system performance and lessons learned during the 2010 Desert Research and Technology Studies (D-RaTS). In addition, this paper will discuss the evolution of the instrumentation system to support the 2011 Deep Space Habitat configuration, the challenges, and the lessons learned of implementing this configuration. In 2010, the HDU was implemented as a pressurized excursion module (PEM) and was tested at NASA s D-RaTS in Arizona [1]. For this initial configuration, the instrumentation system design used features that were successful in previous habitat instrumentation projects, while also considering challenges, and implementing lessons learned [2]. The main feature of the PEM instrumentation system was the use of a standards-based wireless sensor node (WSN), implementing an IEEE 802.15.4 protocol. Many of the instruments were connected to several WSNs, which wirelessly transmitted data to the command and data handling system via a mesh network. The PEM instrumentation system monitored the HDU during field tests at D-RaTS, and the WSN data was later analyzed to understand the performance of this system. In addition, several lessons learned were gained from the field test experience, which fed into the instrumentation design of the next generation of the HDU.

  18. Development of an embedded instrument for autofocus and polarization alignment of polarization maintaining fiber

    NASA Astrophysics Data System (ADS)

    Feng, Di; Fang, Qimeng; Huang, Huaibo; Zhao, Zhengqi; Song, Ningfang

    2017-12-01

    The development and implementation of a practical instrument based on an embedded technique for autofocus and polarization alignment of polarization maintaining fiber is presented. For focusing efficiency and stability, an image-based focusing algorithm fully considering the image definition evaluation and the focusing search strategy was used to accomplish autofocus. For improving the alignment accuracy, various image-based algorithms of alignment detection were developed with high calculation speed and strong robustness. The instrument can be operated as a standalone device with real-time processing and convenience operations. The hardware construction, software interface, and image-based algorithms of main modules are described. Additionally, several image simulation experiments were also carried out to analyze the accuracy of the above alignment detection algorithms. Both the simulation results and experiment results indicate that the instrument can achieve the accuracy of polarization alignment <±0.1 deg.

  19. Instrumental Assessment of Pediatric Dysphagia.

    PubMed

    Arvedson, Joan C; Lefton-Greif, Maureen A

    2017-04-01

    Speech-language pathologists (SLPs) have fulfilled primary roles in the evaluation and management of children with feeding/swallowing disorders for more than five decades. The increased incidence and prevalence of newborns, infants, and children with feeding and swallowing disorders has resulted in increased use of instrumental swallowing evaluations. The videofluoroscopic swallow study and fiberoptic endoscopic evaluation of swallowing are the two most commonly used swallowing assessments by SLPs, with ultrasound used less frequently. This article focuses on updates over the past decade in the procedures and utility of instrumental assessments of swallowing function, and identifies future directions that may enable us to meet the needs of the children who are in our care to attain functional outcomes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Instruments used to assess functional limitations in workers applying for disability benefit: a systematic review.

    PubMed

    Spanjer, Jerry; Groothoff, Johan W; Brouwer, Sandra

    2011-01-01

    To systematically review the quality of the psychometric properties of instruments for assessing functional limitations in workers applying for disability benefit. Electronic searches of Medline, Embase, CINAHL and PsycINFO were performed to identify studies focusing on the psychometric properties of instruments used to assess functional limitations in workers' compensation claimants. Two independent reviewers applied the inclusion criteria to select relevant articles and then evaluated the psychometric qualities of the instruments found. Of the 712 articles that were identified, 10 studies met the inclusion criteria, reporting on four instruments: the Roland-Morris Disability Questionnaire (RMDQ), the Patient-Specific Functional Scale (PSFS), the Isernhagen Work System (IWS) and the Multiperspective Multidimensional Pain Assessment Protocol (MMPAP). The questionnaires (RMDQ and PSFS) did not focus specifically on the work situation and measured three to eight functional limitations. The psychometric qualities of the IWS were poor to moderate. For the MMPAP, only predictive validity was measured. The instruments assessed a range varying between 3 and 34 physical functional limitations. No instruments were found for assessing mental limitations in workers' compensation claimants. Studies on four instruments specifically focusing on assessing physical functional limitations in workers applying for disability benefit were found. All four instruments have limitations regarding their psychometric qualities or contents. Since the RMDQ has the best demonstrated psychometric qualities and takes little time to complete it, we recommend the RMDQ for clinicians in rehabilitation. For the assessment of functional limitations in workers applying for disability benefit a combination of questionnaires, performance tests or interviews together with the judgment by physicians looks the most promising.

  1. A Learning Support System Regarding Motion Trigger for Repetitive Motion Having an Operating Instrument

    ERIC Educational Resources Information Center

    Toyooka, Hiroshi; Matsuura, Kenji; Gotoda, Naka

    2016-01-01

    In the learning support for repetitive motions having an operating instrument, it is necessary for learners to control not only their own body motions but also an instrument corresponding to the body. This study focuses on the repetitive motion learning using single operation instrument without the movement in space; i.e. jump-rope and hula-hoop.…

  2. Aeropropulsion 1987. Session 4: Instrumentation and Controls Research

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The Lewis Research Center has had a long history of research directed toward advancing the national capability in the areas of propulsion research instrumentation and propulsion controls. Some of the major advances from this research that are currently in use are highlighted as well as some of the ongoing and planned research that will strongly impact the future capabilities. The presentations will cover the efforts on research instrumentation and controls as well as the research on high temperature electronics. This introductory section will focus on the major drivers or needs of the aeropropulsion industry that have shaped the instrumentation and controls research programs. Also covered will be the technological opportunities that have greatly impacted the program and that permitted break-throughs in several areas.

  3. Eliminating Survivor Bias in Two-stage Instrumental Variable Estimators.

    PubMed

    Vansteelandt, Stijn; Walter, Stefan; Tchetgen Tchetgen, Eric

    2018-07-01

    Mendelian randomization studies commonly focus on elderly populations. This makes the instrumental variables analysis of such studies sensitive to survivor bias, a type of selection bias. A particular concern is that the instrumental variable conditions, even when valid for the source population, may be violated for the selective population of individuals who survive the onset of the study. This is potentially very damaging because Mendelian randomization studies are known to be sensitive to bias due to even minor violations of the instrumental variable conditions. Interestingly, the instrumental variable conditions continue to hold within certain risk sets of individuals who are still alive at a given age when the instrument and unmeasured confounders exert additive effects on the exposure, and moreover, the exposure and unmeasured confounders exert additive effects on the hazard of death. In this article, we will exploit this property to derive a two-stage instrumental variable estimator for the effect of exposure on mortality, which is insulated against the above described selection bias under these additivity assumptions.

  4. Instrument classification in polyphonic music based on timbre analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Tong

    2001-07-01

    While most previous work on musical instrument recognition is focused on the classification of single notes in monophonic music, a scheme is proposed in this paper for the distinction of instruments in continuous music pieces which may contain one or more kinds of instruments. Highlights of the system include music segmentation into notes, harmonic partial estimation in polyphonic sound, note feature calculation and normalization, note classification using a set of neural networks, and music piece categorization with fuzzy logic principles. Example outputs of the system are `the music piece is 100% guitar (with 90% likelihood)' and `the music piece is 60% violin and 40% piano, thus a violin/piano duet'. The system has been tested with twelve kinds of musical instruments, and very promising experimental results have been obtained. An accuracy of about 80% is achieved, and the number can be raised to 90% if misindexings within the same instrument family are tolerated (e.g. cello, viola and violin). A demonstration system for musical instrument classification and music timbre retrieval is also presented.

  5. One-stage posterior focus debridement, interbody grafts, and posterior instrumentation and fusion in the surgical treatment of thoracolumbar spinal tuberculosis with kyphosis in children: a preliminary report.

    PubMed

    Wang, Yu-Xiang; Zhang, Hong-Qi; Tang, Ming-Xing; Guo, Chao-Feng; Deng, Ang; Wu, Jian-Huang; Liu, Jin-Yang; Deng, Zhansheng; Chen, Jing

    2016-08-01

    The purpose of this study was to determine the efficacy and feasibility of surgical management of children with thoracolumbar spine tuberculosis with kyphosis by using one-stage posterior focus debridement, interbody grafts, and posterior instrumentation and fusion. From October 2010 to September 2013, 21 children with thoracolumbar spinal tuberculosis accompanied by kyphosis were treated with one-stage posterior decompression, interbody grafts, and posterior instrumentation and fusion. There were 13 males and 8 females, aged from 7 to 13 years old (average age 9.9 years). The mean follow-up was 34 months (range26-48 months). Patients were evaluated before and after surgery in terms of ESR, neurologic status, pain, and kyphotic angle. Spinal tuberculosis was completely cured, and the grafted bones were fused in all 21 patients. There was no recurrent tuberculous infection. ESR got normal within 3 months in all patients. The ASIA neurologic classification improved in all cases. Pain relief was obtained in all patients. The average preoperative kyphosis was 29.7° (range 12-42°) and decreased to 5.5° (range 2-10°), postoperatively. There was no significant loss of the correction at the latest follow-up. Our results show that one-stage posterior decompression, interbody grafts, and posterior instrumentation and fusion were an effective treatment for children with thoracolumbar spinal tuberculosis. It is characterized as minimum surgical trauma, good neurologic recovery, good correction of kyphosis, and prevention of progressive kyphosis.

  6. Active Thermal Architecture for Cryogenic Optical Instrumentation (ATACOI)

    NASA Technical Reports Server (NTRS)

    Swenson, Charles; Hunter, Roger C.; Baker, Christopher E.

    2018-01-01

    The Active Thermal Architecture for Cryogenic Optical Instrumentation (ATACOI) project will demonstrate an advanced thermal control system for CubeSats and enable the use of cryogenic electro-optical instrumentation on small satellite platforms. Specifically, the project focuses on the development of a deployable solar tracking radiator, a rotationally flexible rotary union fluid joint, and a thermal/vibrational isolation system for miniature cryogenic detectors. This technology will represent a significant improvement over the current state of the art for CubeSat thermal control, which generally relies on simple passive and conductive methods.

  7. Contribution to harmonic balance calculations of self-sustained periodic oscillations with focus on single-reed instruments.

    PubMed

    Farner, Snorre; Vergez, Christophe; Kergomard, Jean; Lizée, Aude

    2006-03-01

    The harmonic balance method (HBM) was originally developed for finding periodic solutions of electronical and mechanical systems under a periodic force, but has been adapted to self-sustained musical instruments. Unlike time-domain methods, this frequency-domain method does not capture transients and so is not adapted for sound synthesis. However, its independence of time makes it very useful for studying any periodic solution, whether stable or unstable, without care of particular initial conditions in time. A computer program for solving general problems involving nonlinearly coupled exciter and resonator, HARMBAL, has been developed based on the HBM. The method as well as convergence improvements and continuation facilities are thoroughly presented and discussed in the present paper. Applications of the method are demonstrated, especially on problems with severe difficulties of convergence: the Helmholtz motion (square signals) of single-reed instruments when no losses are taken into account, the reed being modeled as a simple spring.

  8. VizieR Online Data Catalog: Observations of binary stars at the WIYN telescope (Horch+, 2017)

    NASA Astrophysics Data System (ADS)

    Horch, E. P.; Casetti-Dinescu, D. I.; Camarata, M. A.; Bidarian, A.; van Altena, W. F.; Sherry, W. H.; Everett, M. E.; Howell, S. B.; Ciardi, D. R.; Henry, T. J.; Nusdeo, D. A.; Winters, J. G.

    2018-05-01

    The observations were carried out over six runs at the WIYN telescope, specifically, 2010 September 17-21, 2010 October 23-26, 2011 June 11-16, 2011 September 7-11, 2011 December 10-11, and 2012 February 4-8. In each case, an observing list was constructed primarily from HDSs and Hipparcos suspected doubles (ESA 1997ESASP1200.....E), double-lined spectroscopic binary stars identified in the Geneva-Copenhagen spectroscopic survey (Nordstroem et al. 2004, Cat. V/117), and stars we have previously found to be double in our own program and reported in earlier papers in this series. For all observations here, the Differential Speckle Survey Instrument (DSSI) was used (Horch et al. 2009AJ....137.5057H). The instrument can mount to either of the Nasmyth ports of the WIYN telescope and takes speckle observations in two filters simultaneously. The DSSI observing program at WIYN began in 2008, and the instrument was upgraded to use two electron-multiplying CCD cameras in 2010 January. More recently, DSSI have also been used at Lowell Observatory's Discovery Channel Telescope (DCT), and at both the Gemini north and Gemini south telescopes. (3 data files).

  9. The Discovery Channel Telescope: Construction and Design Progress, June 2006

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Smith, B. W.; Millis, R. L.; Dunham, E. W.; Wiecha, O. M.; Marshall, H.

    2006-06-01

    The Discovery Channel Telescope (DCT) is a 4.2m telescope under construction in northern Arizona. The DCT is located at a new site near Happy Jack at 2361m elevation, which was selected following a lengthy site testing campaign that demonstrated median ground-level seeing of 0.84-arcsec FWHM. The DCT science mission includes targeted studies of astrophysical and solar system objects utilizing RC and Nasmyth-mounted imaging and spectroscopic instrumentation, and wide-field surveys of KBO’s, Centaurs, NEA’s, and other time-variable objects with a 2-degree FOV prime focus camera.The DCT facility enclosure and control building will be completed this year, including the supports for the telescope mount and dome, the major infrastructure for facility machinery, the instrument laboratory, control and computer rooms, and the auxiliary building for the mirror coating facility. Meanwhile, the 4.3m ULE meniscus primary mirror blank was completed at Corning, Inc., in October 2005, and the 2-3 year mirror figuring effort is due to begin June 2006. The primary mirror and its design support, and the preliminary integrated telescope mount model, were finite-element analyzed to optimize the design of the mirror and top-end support configurations. The prime focus camera design has been refined to achieve atmospheric dispersion-compensated 0.25-arcsec images at 1-degree field radius, from B to I-band, at reduced cost through simplification of glasses to standard types and utilization of spheres on all but two lens surfaces.The Discovery Channel Telescope is a project of the Lowell Observatory with major financial support from Discovery Communications, Inc. (DCI). DCI plans ongoing television programming featuring the construction of the telescope and the research ultimately conducted with the DCT. Lowell Observatory is actively seeking additional partners in the project; interested parties should contact R. L. Millis, Director.

  10. Instrumental and Documentational Approaches: From Technology Use to Documentation Systems in University Mathematics Education

    ERIC Educational Resources Information Center

    Gueudet, Ghislaine; Buteau, Chantal; Mesa, Vilma; Misfeldt, Morten

    2014-01-01

    In this article we present an "instrumental approach" in mathematics education, which focuses on the interactions between students, teachers, and "artefacts." This approach analyses "mediations" attached to the use of a given artefact and "instruments" developed by the subjects from this artefact along…

  11. Qualitative adaptation of child behaviour problem instruments in a developing-country setting.

    PubMed

    Khan, B; Avan, B I

    2014-07-08

    A key barrier to epidemiological research on child behaviour problems in developing countries is the lack of culturally relevant, internationally recognized psychometric instruments. This paper proposes a model for the qualitative adaptation of psychometric instruments in developing-country settings and presents a case study of the adaptation of 3 internationally recognized instruments in Pakistan: the Child Behavior Checklist, the Youth Self-Report and the Teacher's Report Form. This model encompassed a systematic procedure with 6 distinct phases to minimize bias and ensure equivalence with the original instruments: selection, deliberation, alteration, feasibility, testing and formal approval. The process was conducted in collaboration with the instruments' developer. A multidisciplinary working group of experts identified equivalence issues and suggested modifications. Focus group discussions with informants highlighted comprehension issues. Subsequently modified instruments were thoroughly tested. Finally, the instruments' developer approval further validated the qualitative adaptation. The study proposes a rigorous and systematic model to effectively achieve cultural adaptation of psychometric instruments.

  12. Aversive pavlovian responses affect human instrumental motor performance.

    PubMed

    Rigoli, Francesco; Pavone, Enea Francesco; Pezzulo, Giovanni

    2012-01-01

    IN NEUROSCIENCE AND PSYCHOLOGY, AN INFLUENTIAL PERSPECTIVE DISTINGUISHES BETWEEN TWO KINDS OF BEHAVIORAL CONTROL: instrumental (habitual and goal-directed) and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm), have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioral experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behavior, and psychopathology.

  13. Aversive Pavlovian Responses Affect Human Instrumental Motor Performance

    PubMed Central

    Rigoli, Francesco; Pavone, Enea Francesco; Pezzulo, Giovanni

    2012-01-01

    In neuroscience and psychology, an influential perspective distinguishes between two kinds of behavioral control: instrumental (habitual and goal-directed) and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm), have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioral experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behavior, and psychopathology. PMID:23060738

  14. [A focused sound field measurement system by LabVIEW].

    PubMed

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying

    2014-05-01

    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  15. Developing and Testing a New Measurement Instrument for Documenting Instrumental Knowledge Utilisation: The Degrees of Knowledge Utilization (DoKU) Scale

    ERIC Educational Resources Information Center

    Bøllingtoft Knudsen, Søren

    2018-01-01

    Focus on evidence-based policymaking is greater than ever, and public spending on evaluations is rising. A primary merit of these expenditures is that politicians actually use new knowledge instrumentally--to influence and inform decision making. Nevertheless, we know surprisingly little about whether and how research-based knowledge is utilised.…

  16. Instrument Performance Monitoring at Gemini North

    NASA Astrophysics Data System (ADS)

    Emig, Kimberly; Pohlen, M.; Chene, A.

    2014-01-01

    An instrument performance monitoring (IPM) project at the Gemini North Observatory evaluates the delivered throughput and sensitivity of, among other instruments, the Near-Infrared Integral Field Spectrometer (NIFS), the Gemini Near-Infrared Spectrograph (GNIRS), and the Gemini Multi-Object Spectrograph (GMOS-N). Systematic observations of standard stars allow the quality of the instruments and mirror to be assessed periodically. An automated pipeline has been implemented to process and analyze data obtained with NIFS, GNIRS cross-dispersed (XD) and long slit (LS) modes, and GMOS (photometry and spectroscopy). We focus the discussion of this poster on NIFS and GNIRS. We present the spectroscopic throughput determined for ZJHK bands on NIFS, the XJHKLM band for GNIRS XD mode and the K band for GNIRS LS. Additionally, the sensitivity is available for the JHK bands in NIFS and GNIRS XD, and for the K band in GNIRS LS. We consider data taken as early as March 2011. Furthermore, the pipeline setup and the methods used to determine throughput and sensitivity are described.

  17. A new instrument for measuring atmospheric turbulence

    NASA Astrophysics Data System (ADS)

    Jacobs, Danny C.; Edwards, Brett; Stelly, Zak; Gorgievska, Ivana; Westpfahl, David J.; Klinglesmith, Daniel A., III; Creech-Eakman, Michelle J.

    2004-10-01

    The Magdalena Ridge Observatory is a congressionally funded project to deliver a state-of-the-art observatory on the Magdalena Ridge in New Mexico to provide astronomical research, educational and outreach programs to the state. In this paper we report results from one of our undergraduate projects being run at New Mexico Tech. This project focuses on the design and characterization of a novel instrument for sensing the atmospheric flow instabilities related to seeing at the observatory site. The instrument attempts to find the power of turbulence on millisecond time scales by measuring a voltage difference between two active microphones. The principles behind the instrument are explored here and a description of the limitations of the current experimental implementation is given. Initial results from the experiment are presented and compared with simultaneous measurements from a co-located Differential Image Motion Monitor. The instrument is shown to be a valuable and robust tool for monitoring the atmospheric conditions during site testing campaigns, but further data will be needed to confirm the precise nature of the correlation between measurements made with this system and more conventional seeing metrics.

  18. Instrumentation of a rigid pavement system : executive summary, November 1996.

    DOT National Transportation Integrated Search

    1996-11-01

    This research focused on development of a comprehensive field instrumentation program to measure the in-situ responses of a concrete pavement system subjected to Falling Weight Deflectometer (FWD) loading and various environmental conditions. Respons...

  19. Instrumentation of a rigid pavement system : final report, April 1997.

    DOT National Transportation Integrated Search

    2007-04-01

    This research focused on development of a comprehensive field instrumentation program to measure the in-situ responses of a concrete pavement system subjected to Falling Weight Deflectometer (FWD) loading and various environmental conditions. Respons...

  20. Instrumentation: Software-Driven Instrumentation: The New Wave.

    ERIC Educational Resources Information Center

    Salit, M. L.; Parsons, M. L.

    1985-01-01

    Software-driven instrumentation makes measurements that demand a computer as an integral part of either control, data acquisition, or data reduction. The structure of such instrumentation, hardware requirements, and software requirements are discussed. Examples of software-driven instrumentation (such as wavelength-modulated continuum source…

  1. Online Course Design in Higher Education: A Review of National and Statewide Evaluation Instruments

    ERIC Educational Resources Information Center

    Baldwin, Sally; Ching, Yu-Hui; Hsu, Yu-Chang

    2018-01-01

    This research identifies six online course evaluation instruments used nationally or in statewide systems. We examined the characteristics (i.e., number of standards and criteria) and coded the criteria that guide the design of online courses. We discussed the focus of the instruments and their unique features.

  2. Instruments for Imaging from Far to Near

    NASA Technical Reports Server (NTRS)

    Mungas, Greg; Boynton, John; Sepulveda, Cesar

    2009-01-01

    The acronym CHAMP (signifying camera, hand lens, and microscope ) denotes any of several proposed optoelectronic instruments that would be capable of color imaging at working distances that could be varied continuously through a range from infinity down to several millimeters. As in any optical instrument, the magnification, depth of field, and spatial resolution would vary with the working distance. For example, in one CHAMP version, at a working distance of 2.5 m, the instrument would function as an electronic camera with a magnification of 1/100, whereas at a working distance of 7 mm, the instrument would function as a microscope/electronic camera with a magnification of 4.4. Moreover, as described below, when operating at or near the shortest-working-distance/highest-magnification combination, a CHAMP could be made to perform one or more spectral imaging functions. CHAMPs were originally intended to be used in robotic geological exploration of the Moon and Mars. The CHAMP concept also has potential for diverse terrestrial applications that could include remotely controlled or robotic geological exploration, prospecting, field microbiology, environmental surveying, and assembly- line inspection. A CHAMP (see figure) would include two lens cells: (1) a distal cell corresponding to the objective lens assembly of a conventional telescope or microscope and (2) a proximal cell that would contain the focusing camera lens assembly and the camera electronic image-detector chip, which would be of the active-pixel-sensor (APS) type. The distal lens cell would face outward from a housing, while the proximal lens cell would lie in a clean environment inside the housing. The proximal lens cell would contain a beam splitter that would enable simultaneous use of the imaging optics (that is, proximal and distal lens assemblies) for imaging and illumination of the field of view. The APS chip would be mounted on a focal plane on a side face of the beam splitter, while light for

  3. Three-dimensional characterization of tightly focused fields for various polarization incident beams

    NASA Astrophysics Data System (ADS)

    Cai, Yanan; Liang, Yansheng; Lei, Ming; Yan, Shaohui; Wang, Zhaojun; Yu, Xianghua; Li, Manman; Dan, Dan; Qian, Jia; Yao, Baoli

    2017-06-01

    Tightly focused vectorial optical beams have found extensive applications in variety of technical fields like single-molecule detection, optical tweezers, and super-resolution optical microscopy. Such applications require an accurate measurement and manipulation of focal optical fields. We have developed a compact instrument (with dimensions of 35 × 35 × 30 cm3) to rapidly measure the intensity distribution in three dimensions of the focused fields of vectorial beams and any other incident beams. This instrument employs a fluorescent nanoparticle as a probe to scan the focal region to obtain a high spatial resolution of intensity distribution. It integrates a liquid-crystal spatial light modulator to allow for tailoring the point spread function of the optical system, making it a useful tool for multi-purpose and flexible research. The robust applicability of the instrument is verified by measuring the 3D intensity distributions of focal fields of various polarization and wavefront modulated incident beams focused by a high NA (=1.25) objective lens. The minimal data acquisition time achievable in the experiment is about 8 s for a scanning region of 3.2 × 3.2 μm2 (512 × 512 pixels). The measured results are in good agreement with those predicted by the vectorial diffraction theory.

  4. First Light from the 4.3-meter Discovery Channel Telescope At Lowell Observatory

    NASA Astrophysics Data System (ADS)

    Hall, Jeffrey C.; Levine, S.

    2013-01-01

    Seven years after groundbreaking on July 12, 2005, the 4.3-meter Discovery Channel Telescope (DCT) is now complete and into commissioning. We obtained first light images in mid 2012 with a 4K x 4K CCD and have recently obtained our first images with the DCT's main camera, the 6K x 6K Large Monolithic Imager (LMI, see adjacent poster by Massey). We held a celebratory gala on July 21, 2012, in Flagstaff. The DCT's delivered image quality is regularly subarcsecond with near-uniform image quality across the FOV from zenith to >2 airmasses, although we have not fully commissioned the active optics system. We attribute this to the outstanding quality of the mirror figures, performed by the University of Arizona's College of Optical Sciences (for M1) and L3 Brashear (for M2). The instrument cube at the RC focus can accommodate four instruments plus the LMI. Designed and built at Lowell Observatory, the cube also contains the DCT's autoguider and wavefront sensor. First light instruments include the 4000 DeVeny spectrograph (the former KPNO White Spectrograph), a low-resolution, high-throughput IR spectrograph, and a higher-resolution IR spectrograph/imager being built by Goddard Space Flight Center in collaboration with the University of Maryland. We are seeking funding for long-slit and fiber-fed echelle spectrographs for higher resolution optical spectroscopy. The DCT can also be configured to host Nasmyth and prime focus instruments. Discovery Communications and its founder John Hendricks contributed $16M to the $53M cost of the telescope, in return for naming rights and first rights to public, educational use of images in their programming. Analysis of data and publication by astronomers in professional journals follows the same procedure as for any other major telescope facility. Discovery's first DCT feature, "Scanning the Skies," aired on September 9, 2012. Future outreach plans include initiating webcasts to classrooms via the Discovery Education networks

  5. Designing for Instrumentalisation: Constructionist Perspectives on Instrumental Theory

    ERIC Educational Resources Information Center

    Kynigos, Chronis; Psycharis, Giorgos

    2013-01-01

    In this paper we aim to contribute to the process of networking between theoretical frames in mathematics education by means of forging connections between Constructionism and Instrumental Theory to discuss a design for instrumentalisation. We specifically focus on instrumentalisation, i.e. the ways in which students make changes to digital…

  6. Laser-nucleated acoustic cavitation in focused ultrasound.

    PubMed

    Gerold, Bjoern; Kotopoulis, Spiros; McDougall, Craig; McGloin, David; Postema, Michiel; Prentice, Paul

    2011-04-01

    Acoustic cavitation can occur in therapeutic applications of high-amplitude focused ultrasound. Studying acoustic cavitation has been challenging, because the onset of nucleation is unpredictable. We hypothesized that acoustic cavitation can be forced to occur at a specific location using a laser to nucleate a microcavity in a pre-established ultrasound field. In this paper we describe a scientific instrument that is dedicated to this outcome, combining a focused ultrasound transducer with a pulsed laser. We present high-speed photographic observations of laser-induced cavitation and laser-nucleated acoustic cavitation, at frame rates of 0.5×10(6) frames per second, from laser pulses of energy above and below the optical breakdown threshold, respectively. Acoustic recordings demonstrated inertial cavitation can be controllably introduced to the ultrasound focus. This technique will contribute to the understanding of cavitation evolution in focused ultrasound including for potential therapeutic applications. © 2011 American Institute of Physics

  7. The OMPS Limb Profiler instrument

    NASA Astrophysics Data System (ADS)

    Rault, D. F.; Xu, P.

    2011-12-01

    The Ozone Mapping and Profiler Suite (OMPS) will continue the monitoring of the global distribution of the Earth's middle atmosphere ozone and aerosol. OMPS is composed of three instruments, namely the Total Column Mapper (heritage: TOMS, OMI), the Nadir Profiler (heritage: SBUV) and the Limb Profiler (heritage: SOLSE/LORE, OSIRIS, SCIAMACHY, SAGE III). The ultimate goal of the mission is to better understand and quantify the rate of stratospheric ozone recovery. OMPS is scheduled to be launched on the NPOESS Preparatory Project (NPP) platform in October 2011. The focus of the paper will be on the Limb Profiler (LP) instrument. The LP instrument will measure the Earth's limb radiance, from which ozone profile will be retrieved from the upper tropopause uo to 60km. End-to-end studies of the sensor and retrieval algorithm indicate the following expected performance for ozone: accuracy of 5% or better from the tropopause up to 50 km, precision of about 3-5% from 18 to 50 km, and vertical resolution of 1.5-2 km with vertical sampling of 1 km and along-track horizontal sampling of 1 deg latitude. The paper will describe the mission, discuss the retrieval algorithm, and summarize the expected performance. If available, the paper will also present early on-orbit data.

  8. ASQ Program Observation Instrument: A Tool for Assessing School-Age Child Care Quality.

    ERIC Educational Resources Information Center

    O'Connor, Susan; And Others

    ASQ (Assessing School-Aged Child Care Quality) is a system for determining the quality of school-age child care programs. The ASQ Program Observation Instrument is a ten-step, self assessment process to guide program improvement. This instrument does not work well in full-day programs that have a single focus, but works well in programs that offer…

  9. Instrumentation of the Maumee River Crossing : executive summary report.

    DOT National Transportation Integrated Search

    2012-03-01

    This project has focused on the instrumentation, monitoring and testing of the main span unit of the : VGCS, one of Ohios first long-span, cable-stayed bridges and one of only a few dozen such bridges in : service in the nation. This effort looked...

  10. Malaysian English: An Instrumental Analysis of Vowel Contrasts

    ERIC Educational Resources Information Center

    Pillai, Stefanie; Don, Zuraidah Mohd.; Knowles, Gerald; Tang, Jennifer

    2010-01-01

    This paper makes an instrumental analysis of English vowel monophthongs produced by 47 female Malaysian speakers. The focus is on the distribution of Malaysian English vowels in the vowel space, and the extent to which there is phonetic contrast between traditionally paired vowels. The results indicate that, like neighbouring varieties of English,…

  11. Instrumentation for the detection and characterization of exoplanets.

    PubMed

    Pepe, Francesco; Ehrenreich, David; Meyer, Michael R

    2014-09-18

    In no other field of astrophysics has the impact of new instrumentation been as substantial as in the domain of exoplanets. Before 1995 our knowledge of exoplanets was mainly based on philosophical and theoretical considerations. The years that followed have been marked, instead, by surprising discoveries made possible by high-precision instruments. Over the past decade, the availability of new techniques has moved the focus of research from the detection to the characterization of exoplanets. Next-generation facilities will produce even more complementary data that will lead to a comprehensive view of exoplanet characteristics and, by comparison with theoretical models, to a better understanding of planet formation.

  12. Flute-like musical instruments: A toy model investigated through numerical continuation

    NASA Astrophysics Data System (ADS)

    Terrien, Soizic; Vergez, Christophe; Fabre, Benoît

    2013-07-01

    Self-sustained musical instruments (bowed string, woodwind and brass instruments) can be modelled by nonlinear lumped dynamical systems. Among these instruments, flutes and flue organ pipes present the particularity to be modelled as a delay dynamical system. In this paper, such a system, a toy model of flute-like instruments, is studied using numerical continuation. Equilibrium and periodic solutions are explored with respect to the blowing pressure, with focus on amplitude and frequency evolutions along the different solution branches, as well as "jumps" between periodic solution branches. The influence of a second model parameter (namely the inharmonicity) on the behaviour of the system is addressed. It is shown that harmonicity plays a key role in the presence of hysteresis or quasiperiodic regime. Throughout the paper, experimental results on a real instrument are presented to illustrate various phenomena, and allow some qualitative comparisons with numerical results.

  13. First-generation instrumentation for the Discovery Channel Telescope

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Dunham, Edward W.; Massey, Philip; Roe, Henry G.

    2014-07-01

    The 4.3m Discovery Channel Telescope (DCT) has been conducting part-time science operations since January 2013. The f/6.1, 0.5° field-of-view at the RC focus is accessible through the Cassegrain instrument cube assembly, which can support 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. Lowell Observatory has developed the Large Monolithic Imager (LMI), a 12.3' FOV 6K x 6K single CCD camera with a dual filter wheel, and installed at the straight-through, field-corrected RC focal station, which has served as the primary early science DCT instrument. Two low-resolution facility spectrographs are currently under development with first light for each anticipated by early 2015: the upgraded DeVeny Spectrograph, to be utilized for single object optical spectroscopy, and the unique Near-Infrared High-Throughput Spectrograph (NIHTS), optimized for single-shot JHK spectroscopy of faint solar system objects. These spectrographs will be mounted at folded RC ports, and the NIHTS installation will feature simultaneous optical imaging with LMI through use of a dichroic fold mirror. We report on the design, construction, commissioning, and progress of these 3 instruments in detail. We also discuss plans for installation of additional facility instrumentation on the DCT.

  14. Modularized Parallel Neutron Instrument Simulation on the TeraGrid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Meili; Cobb, John W; Hagen, Mark E

    2007-01-01

    In order to build a bridge between the TeraGrid (TG), a national scale cyberinfrastructure resource, and neutron science, the Neutron Science TeraGrid Gateway (NSTG) is focused on introducing productive HPC usage to the neutron science community, primarily the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). Monte Carlo simulations are used as a powerful tool for instrument design and optimization at SNS. One of the successful efforts of a collaboration team composed of NSTG HPC experts and SNS instrument scientists is the development of a software facility named PSoNI, Parallelizing Simulations of Neutron Instruments. Parallelizing the traditional serialmore » instrument simulation on TeraGrid resources, PSoNI quickly computes full instrument simulation at sufficient statistical levels in instrument de-sign. Upon SNS successful commissioning, to the end of 2007, three out of five commissioned instruments in SNS target station will be available for initial users. Advanced instrument study, proposal feasibility evalua-tion, and experiment planning are on the immediate schedule of SNS, which pose further requirements such as flexibility and high runtime efficiency on fast instrument simulation. PSoNI has been redesigned to meet the new challenges and a preliminary version is developed on TeraGrid. This paper explores the motivation and goals of the new design, and the improved software structure. Further, it describes the realized new fea-tures seen from MPI parallelized McStas running high resolution design simulations of the SEQUOIA and BSS instruments at SNS. A discussion regarding future work, which is targeted to do fast simulation for automated experiment adjustment and comparing models to data in analysis, is also presented.« less

  15. From the Museum to the Music Classroom: Teaching the "Umrhubhe" as an Ensemble Instrument

    ERIC Educational Resources Information Center

    Dontsa, Luvuyo

    2008-01-01

    While there is a keen interest in indigenous African instrumental music among South African university music students, indigenous music instruments such as the "umrhubhe" (musical bow without a calabash resonator) have not found their way into the classroom. Most music departments focus on the teaching and learning of western instruments…

  16. Actual curriculum development practices instrument: Testing for factorial validity

    NASA Astrophysics Data System (ADS)

    Foi, Liew Yon; Bakar, Kamariah Abu; Hamzah, Mohd Sahandri Gani; Alwi, Nor Hayati

    2014-09-01

    The Actual Curriculum Development Practices Instrument (ACDP-I) was developed and the factorial validity of the ACDP-I was tested (n = 107) using exploratory factor analysis procedures in the earlier work of [1]. Despite the ACDP-I appears to be content and construct valid instrument with very high internal reliability qualities for using in Malaysia, the accumulated evidences are still needed to provide a sound scientific basis for the proposed score interpretations. Therefore, the present study addresses this concern by utilising the confirmatory factor analysis to further confirm the theoretical structure of the variable Actual Curriculum Development Practices (ACDP) and enrich the psychometrical properties of ACDP-I. Results of this study have practical implication to both researchers and educators whose concerns focus on teachers' classroom practices and the instrument development and validation process.

  17. On-orbit Performance and Calibration of the HMI Instrument

    NASA Astrophysics Data System (ADS)

    Hoeksema, J. Todd; Bush, Rock; HMI Calibration Team

    2016-10-01

    The Helioseismic and Magnetic Imager (HMI) on the Solar Dynamics Observatory (SDO) has observed the Sun almost continuously since the completion of commissioning in May 2010, returning more than 100,000,000 filtergrams from geosynchronous orbit. Diligent and exhaustive monitoring of the instrument's performance ensures that HMI functions properly and allows proper calibration of the full-disk images and processing of the HMI observables. We constantly monitor trends in temperature, pointing, mechanism behavior, and software errors. Cosmic ray contamination is detected and bad pixels are removed from each image. Routine calibration sequences and occasional special observing programs are used to measure the instrument focus, distortion, scattered light, filter profiles, throughput, and detector characteristics. That information is used to optimize instrument performance and adjust calibration of filtergrams and observables.

  18. Which aspects of functioning are relevant for patients with ankylosing spondylitis: results of focus group interviews.

    PubMed

    Boonen, Annelies; van Berkel, Monique; Cieza, Alarcos; Stucki, Gerold; van der Heijde, Désirée

    2009-11-01

    To investigate whether concepts important to patients with ankylosing spondylitis (AS) are covered by disease-specific self-report health status instruments. A qualitative focus group study was conducted with AS patients on problems in daily functioning. Group sessions with 4 to 5 patients each were organized up to the point that no new information was brought forward. Group sessions were tape-recorded, transcribed, and divided into meaning units. Concepts contained in the meaning units were extracted. Self-report instruments on health status specific for AS were identified in a literature search. Using the International Classification of Functioning, Disability and Health (ICF) as a common reference, it was determined whether the concepts identified in the focus groups were covered by the instruments. Nineteen patients participated in 4 focus group interviews. In total, 332 unique meaning units were linked to 90 second-level ICF categories, of which 25 referred to body functions, 10 to body structures, 35 to activities and participation and 30 to environmental factors. In addition, several concepts relating to personal factors were identified. Only 47 categories were also covered by one of the self-report instruments in AS. Only a minority of concepts addressed by the AS-specific questionnaires were not revealed as relevant in the interviews. Relevant aspects of the influence of AS are not covered by the classic disease-specific instruments. In particular, the influence of AS on socializing and leisure and the relevance of environmental and personal factors are not adequately assessed by available instruments.

  19. Satellite-instrument system engineering best practices and lessons

    NASA Astrophysics Data System (ADS)

    Schueler, Carl F.

    2009-08-01

    This paper focuses on system engineering development issues driving satellite remote sensing instrumentation cost and schedule. A key best practice is early assessment of mission and instrumentation requirements priorities driving performance trades among major instrumentation measurements: Radiometry, spatial field of view and image quality, and spectral performance. Key lessons include attention to technology availability and applicability to prioritized requirements, care in applying heritage, approaching fixed-price and cost-plus contracts with appropriate attention to risk, and assessing design options with attention to customer preference as well as design performance, and development cost and schedule. A key element of success either in contract competition or execution is team experience. Perhaps the most crucial aspect of success, however, is thorough requirements analysis and flowdown to specifications driving design performance with sufficient parameter margin to allow for mistakes or oversights - the province of system engineering from design inception to development, test and delivery.

  20. Astronomical Instrumentation Systems Quality Management Planning: AISQMP

    NASA Astrophysics Data System (ADS)

    Goldbaum, Jesse

    2017-06-01

    The capability of small aperture astronomical instrumentation systems (AIS) to make meaningful scientific contributions has never been better. The purpose of AIS quality management planning (AISQMP) is to ensure the quality of these contributions such that they are both valid and reliable. The first step involved with AISQMP is to specify objective quality measures not just for the AIS final product, but also for the instrumentation used in its production. The next step is to set up a process to track these measures and control for any unwanted variation. The final step is continual effort applied to reducing variation and obtaining measured values near optimal theoretical performance. This paper provides an overview of AISQMP while focusing on objective quality measures applied to astronomical imaging systems.

  1. A new innovative instrument for space plasma instrumentation

    NASA Technical Reports Server (NTRS)

    Torbert, Roy B.

    1993-01-01

    The Faraday Ring Ammeter was the subject of this grant for a new innovative instrument for space plasma instrumentation. This report summarizes our progress in this work. Briefly, we have conducted an intensive series of experiments and trials over three years, testing some five configurations of the instrument to measure currents, resulting in two Ph.D. theses, supported by this grant, and two flight configurations of the instrument. The first flight would have been on a NASA-Air Force collaborative sounding rocket, but was not flown because of instrumental difficulties. The second has been successfully integrated on the NASA Auroral Turbulence payload which is to be launched in February, 1994.

  2. ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument

    DOE PAGES

    Fagrelius, Parker; Abareshi, Behzad; Allen, Lori; ...

    2018-01-15

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the universe using the baryon acoustic oscillations technique. The spectra of 35 million galaxies and quasars over 14,000 square degrees will be measured during a 5-year survey. A new prime focus corrector for the Mayall telescope at Kitt Peak National Observatory will deliver light to 5,000 individually targeted fiber-fed robotic positioners. The fibers in turn feed ten broadband multi-object spectrographs. We describe the ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall telescope from 2016 August 14 to September 30. ProtoDESI was anmore » on-sky technology demonstration with the goal to reduce technical risks associated with aligning optical fibers with targets using robotic fiber positioners and maintaining the stability required to operate DESI. The ProtoDESI prime focus instrument, consisting of three fiber positioners, illuminated fiducials, and a guide camera, was installed behind the existing Mosaic corrector on the Mayall telescope. A fiber view camera was mounted in the Cassegrain cage of the telescope and provided feedback metrology for positioning the fibers. ProtoDESI also provided a platform for early integration of hardware with the DESI Instrument Control System that controls the subsystems, provides communication with the Telescope Control System, and collects instrument telemetry data. In conclusion, lacking a spectrograph, ProtoDESI monitored the output of the fibers using a fiber photometry camera mounted on the prime focus instrument. ProtoDESI was successful in acquiring targets with the robotically positioned fibers and demonstrated that the DESI guiding requirements can be met.« less

  3. ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fagrelius, Parker; Abareshi, Behzad; Allen, Lori

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the universe using the baryon acoustic oscillations technique. The spectra of 35 million galaxies and quasars over 14,000 square degrees will be measured during a 5-year survey. A new prime focus corrector for the Mayall telescope at Kitt Peak National Observatory will deliver light to 5,000 individually targeted fiber-fed robotic positioners. The fibers in turn feed ten broadband multi-object spectrographs. We describe the ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall telescope from 2016 August 14 to September 30. ProtoDESI was anmore » on-sky technology demonstration with the goal to reduce technical risks associated with aligning optical fibers with targets using robotic fiber positioners and maintaining the stability required to operate DESI. The ProtoDESI prime focus instrument, consisting of three fiber positioners, illuminated fiducials, and a guide camera, was installed behind the existing Mosaic corrector on the Mayall telescope. A fiber view camera was mounted in the Cassegrain cage of the telescope and provided feedback metrology for positioning the fibers. ProtoDESI also provided a platform for early integration of hardware with the DESI Instrument Control System that controls the subsystems, provides communication with the Telescope Control System, and collects instrument telemetry data. In conclusion, lacking a spectrograph, ProtoDESI monitored the output of the fibers using a fiber photometry camera mounted on the prime focus instrument. ProtoDESI was successful in acquiring targets with the robotically positioned fibers and demonstrated that the DESI guiding requirements can be met.« less

  4. ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument

    NASA Astrophysics Data System (ADS)

    Fagrelius, Parker; Abareshi, Behzad; Allen, Lori; Ballester, Otger; Baltay, Charles; Besuner, Robert; Buckley-Geer, Elizabeth; Butler, Karen; Cardiel, Laia; Dey, Arjun; Duan, Yutong; Elliott, Ann; Emmet, William; Gershkovich, Irena; Honscheid, Klaus; Illa, Jose M.; Jimenez, Jorge; Joyce, Richard; Karcher, Armin; Kent, Stephen; Lambert, Andrew; Lampton, Michael; Levi, Michael; Manser, Christopher; Marshall, Robert; Martini, Paul; Paat, Anthony; Probst, Ronald; Rabinowitz, David; Reil, Kevin; Robertson, Amy; Rockosi, Connie; Schlegel, David; Schubnell, Michael; Serrano, Santiago; Silber, Joseph; Soto, Christian; Sprayberry, David; Summers, David; Tarlé, Greg; Weaver, Benjamin A.

    2018-02-01

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the universe using the baryon acoustic oscillations technique. The spectra of 35 million galaxies and quasars over 14,000 square degrees will be measured during a 5-year survey. A new prime focus corrector for the Mayall telescope at Kitt Peak National Observatory will deliver light to 5,000 individually targeted fiber-fed robotic positioners. The fibers in turn feed ten broadband multi-object spectrographs. We describe the ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall telescope from 2016 August 14 to September 30. ProtoDESI was an on-sky technology demonstration with the goal to reduce technical risks associated with aligning optical fibers with targets using robotic fiber positioners and maintaining the stability required to operate DESI. The ProtoDESI prime focus instrument, consisting of three fiber positioners, illuminated fiducials, and a guide camera, was installed behind the existing Mosaic corrector on the Mayall telescope. A fiber view camera was mounted in the Cassegrain cage of the telescope and provided feedback metrology for positioning the fibers. ProtoDESI also provided a platform for early integration of hardware with the DESI Instrument Control System that controls the subsystems, provides communication with the Telescope Control System, and collects instrument telemetry data. Lacking a spectrograph, ProtoDESI monitored the output of the fibers using a fiber photometry camera mounted on the prime focus instrument. ProtoDESI was successful in acquiring targets with the robotically positioned fibers and demonstrated that the DESI guiding requirements can be met.

  5. Instrument Remote Control via the Astronomical Instrument Markup Language

    NASA Technical Reports Server (NTRS)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  6. Instrument control software requirement specification for Extremely Large Telescopes

    NASA Astrophysics Data System (ADS)

    Young, Peter J.; Kiekebusch, Mario J.; Chiozzi, Gianluca

    2010-07-01

    Engineers in several observatories are now designing the next generation of optical telescopes, the Extremely Large Telescopes (ELT). These are very complex machines that will host sophisticated astronomical instruments to be used for a wide range of scientific studies. In order to carry out scientific observations, a software infrastructure is required to orchestrate the control of the multiple subsystems and functions. This paper will focus on describing the considerations, strategies and main issues related to the definition and analysis of the software requirements for the ELT's Instrument Control System using modern development processes and modelling tools like SysML.

  7. Opto-mechanical design for transmission optics in cryogenic space instrumentation

    NASA Astrophysics Data System (ADS)

    Kroes, Gabby; Venema, Lars; Navarro, Ramón

    2017-11-01

    NOVA is involved in the development and realization of various optical astronomical instruments for groundbased as well as space telescopes, with a focus on nearand mid-infrared instrumentation. NOVA has developed a suite of scientific instruments with cryogenic optics for the ESO VLT and VLTI instruments: VISIR, MIDI, the SPIFFI 2Kcamera for SINFONI, X-shooter and MATISSE. Other projects include the cryogenic optics for MIRI for the James Webb Space Telescope and several E-ELT instruments. Mounting optics is always a compromise between firmly fixing the optics and preventing stresses within the optics. The fixing should ensure mechanical stability and thus accurate positioning in various gravity orientations, temperature ranges, during launch, transport or earthquake. On the other hand, the fixings can induce deformations and sometimes birefringence in the optics and thus cause optical errors. Even cracking or breaking of the optics is a risk, especially when using brittle infrared optical materials at the cryogenic temperatures required in instruments for infrared astronomy, where differential expansion of various materials amounts easily to several millimeters per meter. Special kinematic mounts are therefore needed to ensure both accurate positioning and low stress. This paper concentrates on the opto-mechanical design of optics mountings, especially for large transmission optics in cryogenic circumstances in space instruments. It describes the development of temperature-invariant ("a-thermal") kinematic designs, their implementation in ground based instrumentation and ways to make them suitable for space instruments.

  8. [Development of an evaluation instrument for service quality in nursing homes].

    PubMed

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  9. TAUKAM: a new prime-focus camera for the Tautenburg Schmidt Telescope

    NASA Astrophysics Data System (ADS)

    Stecklum, Bringfried; Eislöffel, Jochen; Klose, Sylvio; Laux, Uwe; Löwinger, Tom; Meusinger, Helmut; Pluto, Michael; Winkler, Johannes; Dionies, Frank

    2016-08-01

    TAUKAM stands for "TAUtenburg KAMera", which will become the new prime-focus imager for the Tautenburg Schmidt telescope. It employs an e2v 6kx6k CCD and is under manufacture by Spectral Instruments Inc. We describe the design of the instrument and the auxiliary components, its specifications as well as the concept for integrating the device into the telescope infrastructure. First light is foreseen in 2017. TAUKAM will boost the observational capabilities of the telescope for what concerns optical wide-field surveys.

  10. Musical Expression: An Observational Study of Instrumental Teaching

    ERIC Educational Resources Information Center

    Karlsson, Jessika; Juslin, Patrik N.

    2008-01-01

    Research has shown that both music students and teachers think that expression is important. Yet, we know little about how expression is taught to students. Such knowledge is needed in order to enhance teaching of expression. The aim of this study was thus to explore the nature of instrumental music teaching in its natural context, with a focus on…

  11. Portable instrument for inspecting irradiated nuclear-fuel assemblies in a water-filled storage pond by measurement of induced Cerenkov radiation

    DOEpatents

    Nicholson, N.; Dowdy, E.J.; Holt, D.M.; Stump, C.J. Jr.

    1982-05-13

    A portable instrument for measuring induced Cerenkov radiation associated with irradiated nuclear fuel assemblies in a water-filled storage pond is disclosed. The instrument includes a photomultiplier tube and an image intensifier which are operable in parallel and simultaneously by means of a field lens assembly and an associated beam splitter. The image intensifier permits an operator to aim and focus the apparatus on a submerged fuel assembly. Once the instrument is aimed and focused, an illumination reading can be obtained with the photomultiplier tube. The instrument includes a lens cap with a carbon-14/phosphor light source for calibrating the apparatus in the field.

  12. Instrumental and Vocal Teacher Education: Competences, Roles and Curricula

    ERIC Educational Resources Information Center

    Lennon, Mary; Reed, Geoffrey

    2012-01-01

    This article focuses on selected outcomes of the European Association of Conservatoires (AEC) "Polifonia" Working Group for Instrumental and Vocal Teacher Training in Europe (2007-2010). The introduction provides the background to the project, explains the rationale and objectives, describes the research process and gives an overview of…

  13. Modern Instrumental Methods in Forensic Toxicology*

    PubMed Central

    Smith, Michael L.; Vorce, Shawn P.; Holler, Justin M.; Shimomura, Eric; Magluilo, Joe; Jacobs, Aaron J.; Huestis, Marilyn A.

    2009-01-01

    This article reviews modern analytical instrumentation in forensic toxicology for identification and quantification of drugs and toxins in biological fluids and tissues. A brief description of the theory and inherent strengths and limitations of each methodology is included. The focus is on new technologies that address current analytical limitations. A goal of this review is to encourage innovations to improve our technological capabilities and to encourage use of these analytical techniques in forensic toxicology practice. PMID:17579968

  14. The Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source

    DOE PAGES

    Ferguson, Ken R.; Bucher, Maximilian; Bozek, John D.; ...

    2015-05-01

    The Atomic, Molecular and Optical Science (AMO) instrument at the Linac Coherent Light Source (LCLS) provides a tight soft X-ray focus into one of three experimental endstations. The flexible instrument design is optimized for studying a wide variety of phenomena requiring peak intensity. There is a suite of spectrometers and two photon area detectors available. An optional mirror-based split-and-delay unit can be used for X-ray pump–probe experiments. Recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument.

  15. Towards more patient centred healthcare: A new Consumer Quality Index instrument to assess patients' experiences with breast care.

    PubMed

    Damman, Olga C; Hendriks, Michelle; Sixma, Herman J

    2009-06-01

    To develop a Consumer Quality Index (CQ-index) Breast Care instrument that measures quality of care from the perspective of patients with (suspicion of) breast cancer. To develop a pilot questionnaire, three focus group discussions with breast cancer patients were performed. The questionnaire was sent to 1197 patients. We performed psychometric and descriptive analyses to optimise the new instrument. Focus group discussions revealed nine main themes related to breast care quality. Psychometric analyses resulted in 15 reliable scales. The final instrument consisted of 152 items, of which 118 items regarded patients' experiences. The aspect with the highest need for quality improvement was informing patients about a second opinion. The CQ-index Breast Care (CQI-BC) instrument provides a good starting point for further research on the quality of breast care seen from the perspective of patients. The newly developed instrument can be used by different stakeholders for future quality monitoring.

  16. On-orbit degradation of recent space-based solar instruments and understanding of the degradation processes

    NASA Astrophysics Data System (ADS)

    Meftah, M.; Dominique, M.; BenMoussa, A.; Dammasch, I. E.; Bolsée, D.; Pereira, N.; Damé, L.; Bekki, S.; Hauchecorne, A.

    2017-05-01

    The space environment is considered hazardous to spacecraft, resulting in materials degradation. Understanding the degradation of space-based instruments is crucial in order to achieve the scientific objectives, which are derived from these instruments. This paper discusses the on-orbit performance degradation of recent spacebased solar instruments. We will focus on the instruments of three space-based missions such as the Project for On-Board Autonomy 2 (PROBA2) spacecraft, the Solar Monitoring Observatory (SOLAR) payload onboard the Columbus science Laboratory of the International Space Station (ISS) and the PICARD spacecraft. Finally, this paper intends to understand the degradation processes of these space-based solar instruments.

  17. Qualitative to Quantitative and Spectrum to Report: An Instrument-Focused Research Methods Course for First-Year Students

    ERIC Educational Resources Information Center

    Thomas, Alyssa C.; Boucher, Michelle A.; Pulliam, Curtis R.

    2015-01-01

    Our Introduction to Research Methods course is a first-year majors course built around the idea of helping students learn to work like chemists, write like chemists, and think like chemists. We have developed this course as a hybrid hands-on/ lecture experience built around instrumentation use and report preparation. We take the product from one…

  18. Mineralogy and astrobiology detection using laser remote sensing instrument.

    PubMed

    Abedin, M Nurul; Bradley, Arthur T; Sharma, Shiv K; Misra, Anupam K; Lucey, Paul G; McKay, Christopher P; Ismail, Syed; Sandford, Stephen P

    2015-09-01

    A multispectral instrument based on Raman, laser-induced fluorescence (LIF), laser-induced breakdown spectroscopy (LIBS), and a lidar system provides high-fidelity scientific investigations, scientific input, and science operation constraints in the context of planetary field campaigns with the Jupiter Europa Robotic Lander and Mars Sample Return mission opportunities. This instrument conducts scientific investigations analogous to investigations anticipated for missions to Mars and Jupiter's icy moons. This combined multispectral instrument is capable of performing Raman and fluorescence spectroscopy out to a >100  m target distance from the rover system and provides single-wavelength atmospheric profiling over long ranges (>20  km). In this article, we will reveal integrated remote Raman, LIF, and lidar technologies for use in robotic and lander-based planetary remote sensing applications. Discussions are focused on recently developed Raman, LIF, and lidar systems in addition to emphasizing surface water ice, surface and subsurface minerals, organics, biogenic, biomarker identification, atmospheric aerosols and clouds distributions, i.e., near-field atmospheric thin layers detection for next robotic-lander based instruments to measure all the above-mentioned parameters.

  19. Instrumental Music for Dyslexics: A Teaching Handbook. Second Edition.

    ERIC Educational Resources Information Center

    Oglethorpe, Sheila

    This book is a guide for music teachers whose students of instrumental keyboard music include those with dyslexia. Chapter 1 is on recognizing dyslexia, including primary and secondary symptoms, multisensory teaching, and teaching to strengths. Chapter 2 focuses on communication between pupil and teacher with sections on music as communication and…

  20. IR Instruments | CTIO

    Science.gov Websites

    Visitor's Computer Guidelines Network Connection Request Instruments Instruments by Telescope IR Instruments ‹› You are here CTIO Home » Astronomers » Instruments » IR Instruments IR Instruments Infrared Imaging ANDICAM - Ohio State Visual/IR Imager (on SMARTS 1.3m Telescope) OSIRIS - The Ohio State

  1. Recent Developments in Instrumentation for Capillary Electrophoresis and Microchip-Capillary Electrophoresis

    PubMed Central

    Felhofer, Jessica L.; Blanes, Lucas; Garcia, Carlos D.

    2010-01-01

    Over the last years there has been an explosion in the number of developments and applications of capillary electrophoresis (CE) and microchip-CE. In part, this growth has been the direct consequence of recent developments in instrumentation associated with CE. This review, which is focused on contributions published in the last five years, is intended to complement the papers presented in this special issue dedicated to Instrumentation and to provide an overview on the general trend and some of the most remarkable developments published in the areas of high voltage power supplies, detectors, auxiliary components, and compact systems. It also includes few examples of alternative uses of and modifications to traditional CE instruments. PMID:20665910

  2. A systematic review of instruments for measuring outcomes in economic evaluation within aged care.

    PubMed

    Bulamu, Norma B; Kaambwa, Billingsley; Ratcliffe, Julie

    2015-11-09

    This paper describes the methods and results of a systematic review to identify instruments used to measure quality of life outcomes in older people. The primary focus of the review was to identify instruments suitable for application with older people within economic evaluations conducted in the aged care sector. Online databases searched were PubMed, Medline, Scopus, and Web of Science, PsycInfo, CINAHL, Embase and Informit. Studies that met the following criteria were included: 1) study population exclusively above 65 years of age 2) measured health status, health related quality of life or quality of life outcomes more broadly through use of an instrument developed for this purpose, 3) used a generic preference based instrument or an older person specific preference based or non-preference based instrument or both, and 4) published in journals in the English language after 2000. The most commonly applied generic preference based instrument in both the community and residential aged care context was the EuroQol - 5 Dimensions (EQ-5D), followed by the Adult Social Care Outcomes Toolkit (ASCOT) and the Health Utilities Index (HUI2/3). The most widely applied older person specific instrument was the ICEpop CAPability measure for Older people (ICECAP-O) in both community and residential aged care. In the absence of an ideal instrument for incorporating into economic evaluations in the aged care sector, this review recommends the use of a generic preference based measure of health related quality of life such as the EQ-5D to obtain quality adjusted life years, in combination with an instrument that has a broader quality of life focus like the ASCOT, which was designed specifically for evaluating interventions in social care or the ICECAP-O, a capability measure for older people.

  3. SEQUenCE: a service user-centred quality of care instrument for mental health services.

    PubMed

    Hester, Lorraine; O'Doherty, Lorna Jane; Schnittger, Rebecca; Skelly, Niamh; O'Donnell, Muireann; Butterly, Lisa; Browne, Robert; Frorath, Charlotte; Morgan, Craig; McLoughlin, Declan M; Fearon, Paul

    2015-08-01

    To develop a quality of care instrument that is grounded in the service user perspective and validate it in a mental health service. The instrument (SEQUenCE (SErvice user QUality of CarE)) was developed through analysis of focus group data and clinical practice guidelines, and refined through field-testing and psychometric analyses. All participants were attending an independent mental health service in Ireland. Participants had a diagnosis of bipolar affective disorder (BPAD) or a psychotic disorder. Twenty-nine service users participated in six focus group interviews. Seventy-one service users participated in field-testing: 10 judged the face validity of an initial 61-item instrument; 28 completed a revised 52-item instrument from which 12 items were removed following test-retest and convergent validity analyses; 33 completed the resulting 40-item instrument. Test-retest reliability, internal consistency and convergent validity of the instrument. The final instrument showed acceptable test-retest reliability at 5-7 days (r = 0.65; P < 0.001), good convergent validity with the Verona Service Satisfaction Scale (r = 0.84, P < 0.001) and good internal consistency (Cronbach's alpha = 0.87). SEQUenCE is a valid, reliable scale that is grounded in the service user perspective and suitable for routine use. It may serve as a useful tool in individual care planning, service evaluation and research. The instrument was developed and validated with service users with a diagnosis of either BPAD or a psychotic disorder; it does not yet have established external validity for other diagnostic groups. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  4. Evolution of Instrumentation for Detection of the Raman Effect as Driven by Available Technologies and by Developing Applications

    ERIC Educational Resources Information Center

    Adar, Fran; Delhaye, Michel; DaSilva, Edouard

    2007-01-01

    The evolution of Raman instrumentation from the time of the initial report of the phenomenon in 1928 to 2006 is discussed. The first instruments were prism-based spectrographs using lenses for collimation and focusing and the 21st century instruments are also spectrographs, but they use CCD cameras. The Lippmann filter technology that appears to…

  5. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Urgiles, E.; Wilcox, J. Z.; Toda, R.; Crisp, J.; George, T.

    2005-01-01

    Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

  6. SAO Participation in the GOME and SCIAMACHY Satellite Instrument Programs

    NASA Technical Reports Server (NTRS)

    Hilsenrath, Ernest (Technical Monitor); Chance, Kelly; Kurosu, Thomas

    2004-01-01

    This report summarizes the progress on our three-year program of research to refine the measurement capability for satellite-based instruments that monitor ozone and other trace species in the Earth's stratosphere and troposphere, to retrieve global distributions of these and other constituents h m the GOME and SCIAMACHY satellite instruments, and to conduct scientific studies for the ILAS instruments. This continues our involvements as a U.S. participant in GOME and SCIAMACHY since their inception, and as a member of the ILAS-II Science Team. These programs have led to the launch of the first satellite instrument specifically designed to measure height-resolved ozone, including the tropospheric component (GOME), and the development of the first satellite instrument that will measure tropospheric ozone simultaneously with NO2, CO, HCHO, N2O, H2O, and CH4 (SCIAMACHY). The GOME program now includes the GOME-2 instruments, to be launched on the Eumetsat Metop satellites, providing long-term continuity in European measurements of global ozone that complement the measurements of the TOMS, SBUV, OMI, OMPS instruments. The research primarily focuses on two areas: Data analysis, including algorithm development and validation studies that will improve the quality of retrieved data products, in support for future field campaigns (to complement in situ and airborne campaigns with satellite measurements), and scientific analyses to be interfaced to atmospheric modeling studies.

  7. SAO Participation in the GOME and SCIAMACHY Satellite Instrument Programs

    NASA Technical Reports Server (NTRS)

    Chance, Kelly; Kurosu, Thomas

    2003-01-01

    This report summarizes the progress on our three-year program of research to refine the measurement capability for satellite-based instruments that monitor ozone and other trace species in the Earth's stratosphere and troposphere, to retrieve global distributions of these and other constituents from the GOME and SCIAMACHY satellite instruments, and to conduct scientific studies for the ILAS instruments. This continues our involvements as a U.S. participant in GOME and SCIAMACHY since their inception, and as a member of the ILAS-II Science Team. These programs have led to the launch of the first satellite instrument specifically designed to measure height-resolved ozone, including the tropospheric component (GOME), and the development of the first satellite instrument that will measure tropospheric ozone simultaneously with NO2, CO, HCHO, N2O, H2O, and CH4 (SCIAMACHY). The GOME program now includes the GOME-2 instruments, to be launched on the Eumetsat Metop satellites, providing long-term continuity in European measurements of global ozone that complement the measurements of the TOMS, SBW, OMI, OMPS instruments. The research primarily focuses on two areas: Data analysis, including algorithm development and validation studies that will improve the quality of retrieved data products, in support for future field campaigns (to complement in situ and airborne campaigns with satellite measurements), and scientific analyses to be interfaced to atmospheric modeling studies.

  8. Development of a Student-Centered Instrument to Assess Middle School Students' Conceptual Understanding of Sound

    ERIC Educational Resources Information Center

    Eshach, Haim

    2014-01-01

    This article describes the development and field test of the Sound Concept Inventory Instrument (SCII), designed to measure middle school students' concepts of sound. The instrument was designed based on known students' difficulties in understanding sound and the history of science related to sound and focuses on two main aspects of sound: sound…

  9. Feedback to Managers: A Review and Comparison of Multi-Rater Instruments for Management Development. Third Edition.

    ERIC Educational Resources Information Center

    Leslie, Jean Brittain; Fleenor, John W.

    This volume describes 24 publicly available multiple-perspective management-assessment instruments that relate self-view to the views of others on multiple management and leadership domains. Each instrument also includes an assessment-for-development focus that scales managers along a continuum of psychometric properties, and "best…

  10. PASSCAL Instrument Center Support for Cryoseismology: Methodologies, Challenges, Development and Instrumentation

    NASA Astrophysics Data System (ADS)

    Beaudoin, B. C.; Anderson, K. R.; Bilek, S. L.; Carpenter, P.; Childs, D.; Chung, P.; Huerta, A. D.; Lingutla, N.; Nikolaus, K.; Winberry, J. P.

    2017-12-01

    Remote portable seismic stations are, in most cases, constrained by logistics and cost. High latitude operations introduce environmental, technical and logistical challenges that require substantially more engineering work to ensure robust, high quality data return. Since 2006, IRIS PASSCAL has been funded by NSF to develop, deploy, and maintain a pool of polar specific seismic stations. At roughly the same time, PASSCAL began supporting experiments specifically targeting glacier dynamics such as the mechanisms of subglacial hydrology, basal shear stress, ice stream stick slip mechanisms, and glacier seismicity. Although much of the development for high-latitude deployments was directly applicable to cryoseismology, these new experiments introduced a unique series of challenges including high ablation, standing water, and moving stations. Our polar development objectives have focused on: Reducing station power requirements, size and weight; Extending the operational temperature of a station; Simplifying logistics; Engineering solutions that are cost effective, manufacturable, serviceable and reusable; And, developing high-latitude communications for both state-of-health and data transmission. To these ends, PASSCAL continues testing new power storage technology, refining established power systems for lighter and smaller power banks, and exploring telemetry solutions to increase high-bandwidth communication options and abilities for remote seismic stations. Further enhancing PASSCAL's ability to support cryoseismology is a recent NSF funded collaborative effort lead by Central Washing University joined by IRIS and New Mexico Tech to build a Geophysical Earth Observatory for Ice Covered Environments (GEOICE). The GEOICE instrument, power system and other integrated ancillary components are designed to require minimal installation time and logistical load (i.e., size and weight), while maximizing ease-of-use in the field and optimizing costs of instrumentation and

  11. The Sound Access Parent Outcomes Instrument (SAPOI): Construction of a new instrument for children with severe multiple disabilities who use cochlear implants or hearing aids.

    PubMed

    Hayward, Denyse V; Ritter, Kathryn; Mousavi, Amin; Vatanapour, Shabnam

    2016-01-01

    To report on the Phase 2 development of the Sound Access Parent Outcomes Instrument (SAPOI), a new instrument focused on formalizing outcomes that parents of children with severe multiple disabilities (SMD) who use amplification prioritize as important. Phase 2 of this project involved item selection and refinement of the SAPOI based on (a) Phase 1 study participant input, (b) clinical specialist feedback, and (c) test-retest instrument reliability. Phase 1 participant responses were utilized to construct a draft version of the SAPOI. Next, clinical specialists examined the instrument for content validity and utility and instrument reliability was examined through a test-retest process with parents of children with SMD. The draft SAPOI was constructed based on Phase 1 participant input. Clinical specialists supported content validity and utility of the instrument and the inclusion of 19 additional items across four categories, namely Child Affect, Child Interaction, Parent Well-being, and Child's Device Use. The SAPOI was completed twice at one-month intervals by parents of children with SMD to examine instrument reliability across the four categories (Child Affect, Child Interaction, Parent Well-being, and Child's Device Use). Instrument reliability was strong-to-excellent across all four sections. The SAPOI shows promise as a much-needed addition to the assessment battery currently used for children with SMD who use cochlear implants and hearing aids. It provides valuable information regarding outcomes resulting from access to sound in this population that currently used assessments do not identify.

  12. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    NASA Astrophysics Data System (ADS)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  13. Response of Nuclear Power Plant Instrumentation Cables Exposed to Fire Conditions.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muna, Alice Baca; LaFleur, Chris Bensdotter; Brooks, Dusty Marie

    This report presents the results of instrumentation cable tests sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research and performed at Sandia National Laboratories (SNL). The goal of the tests was to assess thermal and electrical response behavior under fire-exposure conditions for instrumentation cables and circuits. The test objective was to assess how severe radiant heating conditions surrounding an instrumentation cable affect current or voltage signals in an instrumentation circuit. A total of thirty-nine small-scale tests were conducted. Ten different instrumentation cables were tested, ranging from one conductor to eight-twisted pairs. Because the focus of themore » tests was thermoset (TS) cables, only two of the ten cables had thermoplastic (TP) insulation and jacket material and the remaining eight cables were one of three different TS insulation and jacket material. Two instrumentation cables from previous cable fire testing were included, one TS and one TP. Three test circuits were used to simulate instrumentation circuits present in nuclear power plants: a 4–20 mA current loop, a 10–50 mA current loop and a 1–5 VDC voltage loop. A regression analysis was conducted to determine key variables affecting signal leakage time.« less

  14. Team X Spacecraft Instrument Database Consolidation

    NASA Technical Reports Server (NTRS)

    Wallenstein, Kelly A.

    2005-01-01

    In the past decade, many changes have been made to Team X's process of designing each spacecraft, with the purpose of making the overall procedure more efficient over time. One such improvement is the use of information databases from previous missions, designs, and research. By referring to these databases, members of the design team can locate relevant instrument data and significantly reduce the total time they spend on each design. The files in these databases were stored in several different formats with various levels of accuracy. During the past 2 months, efforts have been made in an attempt to combine and organize these files. The main focus was in the Instruments department, where spacecraft subsystems are designed based on mission measurement requirements. A common database was developed for all instrument parameters using Microsoft Excel to minimize the time and confusion experienced when searching through files stored in several different formats and locations. By making this collection of information more organized, the files within them have become more easily searchable. Additionally, the new Excel database offers the option of importing its contents into a more efficient database management system in the future. This potential for expansion enables the database to grow and acquire more search features as needed.

  15. The Dark Energy Spectroscopic Instrument (DESI)

    NASA Astrophysics Data System (ADS)

    Flaugher, Brenna; Bebek, Chris

    2014-07-01

    The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations (BAO) and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar spectroscopic redshift survey. The DESI instrument consists of a new wide-field (3.2 deg. linear field of view) corrector plus a multi-object spectrometer with up to 5000 robotically positioned optical fibers and will be installed at prime focus on the Mayall 4m telescope at Kitt Peak, Arizona. The fibers feed 10 three-arm spectrographs producing spectra that cover a wavelength range from 360-980 nm and have resolution of 2000-5500 depending on the wavelength. The DESI instrument is designed for a 14,000 sq. deg. multi-year survey of targets that trace the evolution of dark energy out to redshift 3.5 using the redshifts of luminous red galaxies (LRGs), emission line galaxies (ELGs) and quasars. DESI is the successor to the successful Stage-III BOSS spectroscopic redshift survey and complements imaging surveys such as the Stage-III Dark Energy Survey (DES, currently operating) and the Stage-IV Large Synoptic Survey Telescope (LSST, planned start early in the next decade).

  16. Development of Physics Attitude Scale (PAS): An Instrument to Measure Students' Attitudes toward Physics

    ERIC Educational Resources Information Center

    Kaur, Daisy; Zhao, Yi

    2017-01-01

    The present study is focused on the detailed description of Physics Attitude Scale (PAS) to measure students' attitudes toward physics. The development of this new instrument involved extensive interviews with both the experts as well as the students. This was followed by expert reviews and pilot testing of the instrument. The duly revised draft…

  17. Measuring first-line nurse manager work: instrument: development and testing.

    PubMed

    Cadmus, Edna; Wisniewska, Edyta K

    2013-12-01

    The objective of this study was to develop and test a 1st-line nurse manager (FLNM) work instrument to measure categories of work and frequency of activities. First-line nurse managers have been demonstrated to be key contributors in meeting organizational outcomes and patient and nurse satisfaction. Identifying the work of FLNMs is essential to help in the development of prioritization and sequence. The need for an instrument that can measure and categorize the work of FLNMs is indicated. The author-developed instrument was administered as a pilot study to 173 FLNMs in New Jersey. Descriptive statistics were analyzed, and validity and reliability were measured. Content validity was established through 2 focus groups using 10 FLNMs and conducting a survey of 5 chief nursing officers. Reliability was assessed by 13 of 16 FLNM participants using the test/retest method and quantified using percent agreement within a 10-day period. Those items with 70% agreement or more were identified as reliable and retained on the instrument. The content validity of the instrument is strong; further refinement and testing of the tool are indicated to improve the reliability and generalizability across multiple populations of leaders and settings.

  18. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications.

    PubMed

    Týčová, Anna; Ledvina, Vojtěch; Klepárník, Karel

    2017-01-01

    This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices coupled with MS for detection and identification of important analytes. It is a continuation of the review article on the same topic by Kleparnik (Electrophoresis 2015, 36, 159-178). A wide selection of 161 relevant articles covers the literature published from June 2014 till May 2016. New improvements in the instrumentation and methodology of MS interfaced with capillary or microfluidic versions of zone electrophoresis, isotachophoresis, and isoelectric focusing are described in detail. The most frequently implemented MS ionization methods include electrospray ionization, matrix-assisted desorption/ionization and inductively coupled plasma ionization. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single-cell analysis. The combinations of MS with capillary versions of electrochromatography, and micellar electrokinetic chromatography are not included. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A Mixed Methods Portrait of Urban Instrumental Music Teaching

    ERIC Educational Resources Information Center

    Fitzpatrick, Kate R.

    2011-01-01

    The purpose of this mixed methods study was to learn about the ways that instrumental music teachers in Chicago navigated the urban landscape. The design of the study most closely resembles Creswell and Plano Clark's (2007) two-part Triangulation Convergence Mixed Methods Design, with the addition of an initial exploratory focus group component.…

  20. netherland hydrological modeling instrument

    NASA Astrophysics Data System (ADS)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    decision supports and evaluations. The main focus of the instrument is operational drought management and evaluating adaptive measures for different climate scenario's. It has also been used though as a basis to evaluate water quality of WFD-water bodies and measures, nutrient-leaching and describing WFD groundwater bodies. There is a toolkit to translate the hydrological NHI results to values for different water users. For instance with the NHI results agricultural yields can be calculated, effects on ground water dependant ecosystems, subsidence, shipping, drinking water supply. This makes NHI a valuable decision support system in Dutch water management.

  1. Highly Sophisticated Virtual Laboratory Instruments in Education

    NASA Astrophysics Data System (ADS)

    Gaskins, T.

    2006-12-01

    Many areas of Science have advanced or stalled according to the ability to see what can not normally be seen. Visual understanding has been key to many of the world's greatest breakthroughs, such as discovery of DNAs double helix. Scientists use sophisticated instruments to see what the human eye can not. Light microscopes, scanning electron microscopes (SEM), spectrometers and atomic force microscopes are employed to examine and learn the details of the extremely minute. It's rare that students prior to university have access to such instruments, or are granted full ability to probe and magnify as desired. Virtual Lab, by providing highly authentic software instruments and comprehensive imagery of real specimens, provides them this opportunity. Virtual Lab's instruments let explorers operate virtual devices on a personal computer to examine real specimens. Exhaustive sets of images systematically and robotically photographed at thousands of positions and multiple magnifications and focal points allow students to zoom in and focus on the most minute detail of each specimen. Controls on each Virtual Lab device interactively and smoothly move the viewer through these images to display the specimen as the instrument saw it. Users control position, magnification, focal length, filters and other parameters. Energy dispersion spectrometry is combined with SEM imagery to enable exploration of chemical composition at minute scale and arbitrary location. Annotation capabilities allow scientists, teachers and students to indicate important features or areas. Virtual Lab is a joint project of NASA and the Beckman Institute at the University of Illinois at Urbana- Champaign. Four instruments currently compose the Virtual Lab suite: A scanning electron microscope and companion energy dispersion spectrometer, a high-power light microscope, and a scanning probe microscope that captures surface properties to the level of atoms. Descriptions of instrument operating principles and

  2. Astronomical Instrumentation Systems Quality Management Planning: AISQMP (Abstract)

    NASA Astrophysics Data System (ADS)

    Goldbaum, J.

    2017-12-01

    (Abstract only) The capability of small aperture astronomical instrumentation systems (AIS) to make meaningful scientific contributions has never been better. The purpose of AIS quality management planning (AISQMP) is to ensure the quality of these contributions such that they are both valid and reliable. The first step involved with AISQMP is to specify objective quality measures not just for the AIS final product, but also for the instrumentation used in its production. The next step is to set up a process to track these measures and control for any unwanted variation. The final step is continual effort applied to reducing variation and obtaining measured values near optimal theoretical performance. This paper provides an overview of AISQMP while focusing on objective quality measures applied to astronomical imaging systems.

  3. The PEACE project review of clinical instruments for hospice and palliative care.

    PubMed

    Hanson, Laura C; Scheunemann, Leslie P; Zimmerman, Sheryl; Rokoske, Franziska S; Schenck, Anna P

    2010-10-01

    Hospice and palliative care organizations are expanding their use of standardized instruments and other approaches to measure quality. We undertook a systematic review and evaluation of published patient-level instruments for potential application in hospice and palliative care clinical quality measurement. We searched prior reviews and computerized reference databases from 1990 through February 2007 for studies of instruments relevant to physical, psychological, social, cultural, spiritual, or ethical aspects of palliative care, or measuring prognosis, function or continuity of care. Publications were selected for full review if they provided evidence of psychometric properties or practical application of an instrument tested in or appropriate for a hospice or palliative care population. Selected instruments were evaluated and scored for scientific soundness and potential application in clinical quality measurement. The search found 1427 publications, with 229 selected for full manuscript review. Manuscripts provided information on 129 instruments which were evaluated using a structured scoring guide for psychometric properties. Thirty-nine instruments scoring near or above the 75th percentile were recommended. Most instruments covered multiple domains or focused on care for physical symptoms, psychological or social aspects of care. Few instruments were available to measure cultural aspects of care, structure and process of care, and continuity of care. Numerous patient-level instruments are available to measure physical, psychological and social aspects of palliative care with adequate evidence for scientific soundness and practical clinical use for quality improvement and research. Other aspects of palliative care may benefit from further instrument development research.

  4. Cryogenic filter wheel design for an infrared instrument

    NASA Astrophysics Data System (ADS)

    Azcue, Joaquín.; Villanueva, Carlos; Sánchez, Antonio; Polo, Cristina; Reina, Manuel; Carretero, Angel; Torres, Josefina; Ramos, Gonzalo; Gonzalez, Luis M.; Sabau, Maria D.; Najarro, Francisco; Pintado, Jesús M.

    2014-09-01

    In the last two decades, Spain has built up a strong IR community which has successfully contributed to space instruments, reaching Co-PI level in the SPICA mission (Space Infrared Telescope for Cosmology and Astrophysics). Under the SPICA mission, INTA, focused on the SAFARI instrument requirements but highly adaptable to other missions has designed a cryogenic low dissipation filter wheel with six positions, taking as starting point the past experience of the team with the OSIRIS instrument (ROSETTA mission) filter wheels and adapting the design to work at cryogenic temperatures. One of the main goals of the mechanism is to use as much as possible commercial components and test them at cryogenic temperature. This paper is focused on the design of the filter wheel, including the material selection for each of the main components of the mechanism, the design of elastic mount for the filter assembly, a positioner device designed to provide positional accuracy and repeatability to the filter, allowing the locking of the position without dissipation. In order to know the position of the wheel on every moment a position sensor based on a Hall sensor was developed. A series of cryogenic tests have been performed in order to validate the material configuration selected, the ball bearing lubrication and the selection of the motor. A stepper motor characterization campaign was performed including heat dissipation measurements. The result is a six position filter wheel highly adaptable to different configurations and motors using commercial components. The mechanism was successfully tested at INTA facilities at 20K at breadboard level.

  5. OMPS Limb Profiler Instrument Performance Assessment

    NASA Technical Reports Server (NTRS)

    Jaross, Glen R.; Bhartia, Pawan K.; Chen, Grace; Kowitt, Mark; Haken, Michael; Chen, Zhong; Xu, Philippe; Warner, Jeremy; Kelly, Thomas

    2014-01-01

    Following the successful launch of the Ozone Mapping and Profiler Suite (OMPS) aboard the Suomi National Polar-orbiting Partnership (SNPP) spacecraft, the NASA OMPS Limb team began an evaluation of instrument and data product performance. The focus of this paper is the instrument performance in relation to the original design criteria. Performance that is closer to expectations increases the likelihood that limb scatter measurements by SNPP OMPS and successor instruments can form the basis for accurate long-term monitoring of ozone vertical profiles. The team finds that the Limb instrument operates mostly as designed and basic performance meets or exceeds the original design criteria. Internally scattered stray light and sensor pointing knowledge are two design challenges with the potential to seriously degrade performance. A thorough prelaunch characterization of stray light supports software corrections that are accurate to within 1% in radiances up to 60 km for the wavelengths used in deriving ozone. Residual stray light errors at 1000nm, which is useful in retrievals of stratospheric aerosols, currently exceed 10%. Height registration errors in the range of 1 km to 2 km have been observed that cannot be fully explained by known error sources. An unexpected thermal sensitivity of the sensor also causes wavelengths and pointing to shift each orbit in the northern hemisphere. Spectral shifts of as much as 0.5nm in the ultraviolet and 5 nm in the visible, and up to 0.3 km shifts in registered height, must be corrected in ground processing.

  6. Extending the frontiers of mass spectrometric instrumentation and methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schieffer, Gregg Martin

    2010-01-01

    The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imagingmore » plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it

  7. Instrumental variables and Mendelian randomization with invalid instruments

    NASA Astrophysics Data System (ADS)

    Kang, Hyunseung

    Instrumental variables (IV) methods have been widely used to determine the causal effect of a treatment, exposure, policy, or an intervention on an outcome of interest. The IV method relies on having a valid instrument, a variable that is (A1) associated with the exposure, (A2) has no direct effect on the outcome, and (A3) is unrelated to the unmeasured confounders associated with the exposure and the outcome. However, in practice, finding a valid instrument, especially those that satisfy (A2) and (A3), can be challenging. For example, in Mendelian randomization studies where genetic markers are used as instruments, complete knowledge about instruments' validity is equivalent to complete knowledge about the involved genes' functions. The dissertation explores the theory, methods, and application of IV methods when invalid instruments are present. First, when we have multiple candidate instruments, we establish a theoretical bound whereby causal effects are only identified as long as less than 50% of instruments are invalid, without knowing which of the instruments are invalid. We also propose a fast penalized method, called sisVIVE, to estimate the causal effect. We find that sisVIVE outperforms traditional IV methods when invalid instruments are present both in simulation studies as well as in real data analysis. Second, we propose a robust confidence interval under the multiple invalid IV setting. This work is an extension of our work on sisVIVE. However, unlike sisVIVE which is robust to violations of (A2) and (A3), our confidence interval procedure provides honest coverage even if all three assumptions, (A1)-(A3), are violated. Third, we study the single IV setting where the one IV we have may actually be invalid. We propose a nonparametric IV estimation method based on full matching, a technique popular in causal inference for observational data, that leverages observed covariates to make the instrument more valid. We propose an estimator along with

  8. Selected configuration tradeoffs of contour optical instruments

    NASA Astrophysics Data System (ADS)

    Warren, J.; Strohbehn, K.; Murchie, S.; Fort, D.; Reynolds, E.; Heyler, G.; Peacock, K.; Boldt, J.; Darlington, E.; Hayes, J.; Henshaw, R.; Izenberg, N.; Kardian, C.; Lees, J.; Lohr, D.; Mehoke, D.; Schaefer, E.; Sholar, T.; Spisz, T.; Willey, C.; Veverka, J.; Bell, J.; Cochran, A.

    2003-01-01

    The Comet Nucleus Tour (CONTOUR) is a low-cost NASA Discovery mission designed to conduct three close flybys of comet nuclei. Selected configuration tradeoffs conducted to balance science requirements with low mission cost are reviewed. The tradeoffs discussed focus on the optical instruments and related spacecraft considerations. Two instruments are under development. The CONTOUR Forward Imager (CFI) is designed to perform optical navigation, moderate resolution nucleus/jet imaging, and imaging of faint molecular emission bands in the coma. The CONTOUR Remote Imager and Spectrometer (CRISP) is designed to obtain high-resolution multispectral images of the nucleus, conduct spectral mapping of the nucleus surface, and provide a backup optical navigation capability. Tradeoffs discussed are: (1) the impact on the optical instruments of not using reaction wheels on the spacecraft, (2) the improved performance and simplification gained by implementing a dedicated star tracker instead of including this function in CFI, (3) the improved flexibility and robustness of switching to a low frame rate tracker for CRISP, (4) the improved performance and simplification of replacing a visible imaging spectrometer by enhanced multispectral imaging in CRISP, and (5) the impact on spacecraft resources of these and other tradeoffs.

  9. Physics education in the Greek community schools of Istanbul (19th century). Scientific instruments and experiments in electrostatics

    NASA Astrophysics Data System (ADS)

    Lazos, Panagiotis; Vlahakis, George N.

    2016-03-01

    The Greek schools operating in Istanbul date back to the 19th century. These schools have noteworthy collections of old scientific instruments that were used in teaching experimental physics. Amongst them, more outstanding are the scientific instruments used in demonstrating electrostatics. This paper briefly presents the equipment, focuses on exceptional scientific instruments and attempts to illuminate certain aspects in teaching the natural sciences.

  10. Higher Education and Students with Orthopedic Disabilities: A Survey Instrument.

    ERIC Educational Resources Information Center

    Singh, Delar K.

    A survey instrument is presented that was used in a national survey of 160 colleges and universities to explore facilities and services to students with orthopedic disabilities. The survey contains 33 items that focus on the following areas: structural accessibility, academic accessibility, dorm-living, and recreational opportunities. The total…

  11. Cordless Instruments

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Black & Decker's new cordless lightweight battery powered precision instruments, adapted from NASA's Apollo Lunar Landing program, have been designed to give surgeons optimum freedom and versatility in the operating room. Orthopedic instrument line includes a drill, a driver/reamer and a sagittal saw. All provide up to 20 minutes on a single charge. Power pack is the instrument's handle which is removable for recharging. Microprocessor controlled recharging unit can recharge two power packs together in 30 minutes. Instruments can be gas sterilized, steam-sterilized in an autoclave or immersed for easy cleaning.

  12. Materials for VPHGs: practical considerations in the case of astronomical instrumentation

    NASA Astrophysics Data System (ADS)

    Bianco, Andrea; Pariani, Giorgio; Zanutta, Alessio; Bertarelli, Chiara

    2012-09-01

    Volume Phase Holographic Gratings are interesting dispersing elements for astronomical instrumentation. An important point, in the realization of the grating, is the choice of the holographic material. Dichromated Gelatines (DCGs) are the best candidate, but they show some drawback especially regarding their water sensitivity and the complex developing process required to enhance their performances. New holographic materials are becoming interesting, such as photopolymers and photochromic materials. An exhaustive review of these classes of materials will be reported and their performances compared to those of DCGs, focusing mainly to the astronomical instrumentation field.

  13. Thermal control modeling approach for GRAPE (GRAntecan PolarimEter)

    NASA Astrophysics Data System (ADS)

    Di Varano, I.; Woche, M.; Strassmeier, K. G.

    2016-08-01

    GRAPE is the polarimeter planned to be installed on the main Cassegrain focus of GTC (Gran Telescopio Canarias), having an equivalent entrance pupil of 10.4 m, located at the Observatorio del Roque de los Muchachos (ORM) , in La Palma, Canary Islands. It's meant to deliver full Stokes (IQUV) polarimetry covering the spectral range 0.420-1.6 μ, in order to feed the HORS instrument (High Optical Resolution Spectrograph), mounted on the Nasmyth platform, which has a FWHM resolving power of about 25,000 (5 pixel) designed for the wavelength range of 380-800 nm. Two calcite blocks and a BK-7 prism arranged in a Foster configuration are splitting the Ø12.5mm collimated beam into the ordinary and extraordinary components. The entire subunit from the Foster prisms down to the input fibers is rotated by steps of 45 degrees in order to retrieve Q, U components. By inserting a quarter wave retarder plate before the entrance to the Foster unit circular polarization is measured too. The current paper consist of two main parts: at first CFD simulations are introduced, which have been run compliant to the specifications derived by the environmental conditions and the transient thermal gradients taking into account the presence of the electronic cabinets installed, which are triggering the boundary conditions for the outer structure of the instrument; then a thermal control model is proposed based on heat exchangers to stabilize the inner temperature when compensation via passive insulation is not enough. The tools that have been adopted to reach for such goal are Ansys Multiphysics, in particular CFX package and Python scripts.

  14. Development and validation of instrument for ergonomic evaluation of tablet arm chairs

    PubMed Central

    Tirloni, Adriana Seára; dos Reis, Diogo Cunha; Bornia, Antonio Cezar; de Andrade, Dalton Francisco; Borgatto, Adriano Ferreti; Moro, Antônio Renato Pereira

    2016-01-01

    The purpose of this study was to develop and validate an evaluation instrument for tablet arm chairs based on ergonomic requirements, focused on user perceptions and using Item Response Theory (IRT). This exploratory study involved 1,633 participants (university students and professors) in four steps: a pilot study (n=26), semantic validation (n=430), content validation (n=11) and construct validation (n=1,166). Samejima's graded response model was applied to validate the instrument. The results showed that all the steps (theoretical and practical) of the instrument's development and validation processes were successful and that the group of remaining items (n=45) had a high consistency (0.95). This instrument can be used in the furniture industry by engineers and product designers and in the purchasing process of tablet arm chairs for schools, universities and auditoriums. PMID:28337099

  15. A scanning Hartmann focus test for the EUVI telescopes aboard STEREO

    NASA Astrophysics Data System (ADS)

    Ohl, R., IV; Antonille, S.; Aronstein, D.; Dean, B.; Delmont, M.; d'Entremont, J.; Eichhorn, W.; Frey, B.; Hynes, S.; Janssen, D.; Kubalak, D.; Redman, K.; Shiri, R.; Smith, J. S.; Thompson, P.; Wilson, M.

    2007-09-01

    The Solar TErrestrial RElations Observatory (STEREO), the third mission in NASA's Solar Terrestrial Probes program, was launched in 2006 on a two year mission to study solar phenomena. STEREO consists of two nearly identical satellites, each carrying an Extreme Ultraviolet Imager (EUVI) telescope as part of the Sun Earth Connection Coronal and Heliospheric Investigation instrument suite. EUVI is a normal incidence, 98mm diameter, Ritchey-Chrétien telescope designed to obtain wide field of view images of the Sun at short wavelengths (17.1-30.4nm) using a CCD detector. The telescope entrance aperture is divided into four quadrants by a mask near the secondary mirror spider veins. A mechanism that rotates another mask allows only one of these sub-apertures to accept light over an exposure. The EUVI contains no focus mechanism. Mechanical models predict a difference in telescope focus between ambient integration conditions and on-orbit operation. We describe an independent check of the ambient, ultraviolet, absolute focus setting of the EUVI telescopes after they were integrated with their respective spacecraft. A scanning Hartmann-like test design resulted from constraints imposed by the EUVI aperture select mechanism. This inexpensive test was simultaneously coordinated with other integration and test activities in a high-vibration, clean room environment. The total focus test error was required to be better than +/-0.05mm. We cover the alignment and test procedure, sources of statistical and systematic error, data reduction and analysis, and results using various algorithms for determining focus. The results are consistent with other tests of instrument focus alignment and indicate that the EUVI telescopes meet the ambient focus offset requirements. STEREO and the EUVI telescopes are functioning well on-orbit.

  16. Assessing women's sexuality after cancer therapy: checking assumptions with the focus group technique.

    PubMed

    Bruner, D W; Boyd, C P

    1999-12-01

    Cancer and cancer therapies impair sexual health in a multitude of ways. The promotion of sexual health is therefore vital for preserving quality of life and is an integral part of total or holistic cancer management. Nursing, to provide holistic care, requires research that is meaningful to patients as well as the profession to develop educational and interventional studies to promote sexual health and coping. To obtain meaningful research data instruments that are reliable, valid, and pertinent to patients' needs are required. Several sexual functioning instruments were reviewed for this study and found to be lacking in either a conceptual foundation or psychometric validation. Without a defined conceptual framework, authors of the instruments must have made certain assumptions regarding what women undergoing cancer therapy experience and what they perceive as important. To check these assumptions before assessing women's sexuality after cancer therapies in a larger study, a pilot study was designed to compare what women experience and perceive as important regarding their sexuality with what is assessed in several currently available research instruments, using the focus group technique. Based on the focus group findings, current sexual functioning questionnaires may be lacking in pertinent areas of concern for women treated for breast or gynecologic malignancies. Better conceptual foundations may help future questionnaire design. Self-regulation theory may provide an acceptable conceptual framework from which to develop a sexual functioning questionnaire.

  17. Comparing Binaural Pre-processing Strategies I: Instrumental Evaluation.

    PubMed

    Baumgärtel, Regina M; Krawczyk-Becker, Martin; Marquardt, Daniel; Völker, Christoph; Hu, Hongmei; Herzke, Tobias; Coleman, Graham; Adiloğlu, Kamil; Ernst, Stephan M A; Gerkmann, Timo; Doclo, Simon; Kollmeier, Birger; Hohmann, Volker; Dietz, Mathias

    2015-12-30

    In a collaborative research project, several monaural and binaural noise reduction algorithms have been comprehensively evaluated. In this article, eight selected noise reduction algorithms were assessed using instrumental measures, with a focus on the instrumental evaluation of speech intelligibility. Four distinct, reverberant scenarios were created to reflect everyday listening situations: a stationary speech-shaped noise, a multitalker babble noise, a single interfering talker, and a realistic cafeteria noise. Three instrumental measures were employed to assess predicted speech intelligibility and predicted sound quality: the intelligibility-weighted signal-to-noise ratio, the short-time objective intelligibility measure, and the perceptual evaluation of speech quality. The results show substantial improvements in predicted speech intelligibility as well as sound quality for the proposed algorithms. The evaluated coherence-based noise reduction algorithm was able to provide improvements in predicted audio signal quality. For the tested single-channel noise reduction algorithm, improvements in intelligibility-weighted signal-to-noise ratio were observed in all but the nonstationary cafeteria ambient noise scenario. Binaural minimum variance distortionless response beamforming algorithms performed particularly well in all noise scenarios. © The Author(s) 2015.

  18. On the structural logic of curriculum system for the optical instrument major

    NASA Astrophysics Data System (ADS)

    Yan, Yufeng; Yan, Juncen; Li, Yang; Shi, Lixia

    2017-08-01

    The theories of optical instrument are the Interdisciplinary of Optical Engineering and Instrument Science and Technology. The undergraduates should study the knowledge about the optics, precision machine and electronics. The courses such as Theory of Machine, Engineering Optics, even include some courses about Accuracy Analysis of Instrument are offered in the college. There are a lot of correlatives among these courses. This paper focuses on the structural logic of these courses. The order of these courses is researched, The aims of all the courses are clear completely to avoid the same topics to be taught twice in different courses. Therefore, the undergraduates would get the main line of the knowledge, and the professors would teach efficiently.

  19. CARMENES instrument overview

    NASA Astrophysics Data System (ADS)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  20. Subjective health literacy: Development of a brief instrument for school-aged children.

    PubMed

    Paakkari, Olli; Torppa, Minna; Kannas, Lasse; Paakkari, Leena

    2016-12-01

    The present paper focuses on the measurement of health literacy (HL), which is an important determinant of health and health behaviours. HL starts to develop in childhood and adolescence; hence, there is a need for instruments to monitor HL among younger age groups. These instruments are still rare. The aim of the project reported here was, therefore, to develop a brief, multidimensional, theory-based instrument to measure subjective HL among school-aged children. The development of the instrument covered four phases: item generation based on a conceptual framework; a pilot study ( n = 405); test-retest ( n = 117); and construction of the instrument ( n = 3853). All the samples were taken from Finnish 7th and 9th graders. Initially, 65 items were generated, of which 32 items were selected for the pilot study. After item reduction, the instrument contained 16 items. The test-retest phase produced estimates of stability. In the final phase a 10-item instrument was constructed, referred to as Health Literacy for School-Aged Children (HLSAC). The instrument exhibited a high Cronbach alpha (0.93), and included two items from each of the five predetermined theoretical components (theoretical knowledge, practical knowledge, critical thinking, self-awareness, citizenship). The iterative and validity-driven development process made it possible to construct a brief multidimensional HLSAC instrument. Such instruments are suitable for large-scale studies, and for use with children and adolescents. Validation will require further testing for use in other countries.

  1. Infrared instrument support for HyspIRI-TIR

    NASA Astrophysics Data System (ADS)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2012-10-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

  2. [Professionalization of Legal Dental Experts in Germany: Results of Studies on Structured Focus Groups].

    PubMed

    Brauer, H U; Walther, W; Dick, M

    2018-04-01

    Legal expert opinions are a crucial instrument of professional self-control in medicine. To give impulses for further development, focus groups were initiated to reflect upon the perspective of legal dental experts. 5 focus group discussions on the topic "Professionalization of legal dental experts" were conducted. A total of 32 experienced legal dental experts participated in the discussions. The results were evaluated by qualitative content analysis. A catalogue of 68 ideas was generated for improvement and divided into 15 categories. Among these were periodic quality circles, interprofessional exchange, supervision of novices and periodic feedback for legal dental experts and dentists. Self-reflection can be included as an instrument for quality improvement of legal dental expert opinions. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination.

    PubMed

    Goldin, F J; Meehan, B T; Hagen, E C; Wilkins, P R

    2010-10-01

    A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

  4. Learning Mathematics in a CAS Environment: The Genesis of a Reflection about Instrumentation and the Dialectics between Technical and Conceptual Work.

    ERIC Educational Resources Information Center

    Artigue, Michele

    2002-01-01

    Presents an anthropological approach used in French research and the theory of instrumentation developed in cognitive ergonomics. Shows how these frameworks allow an approach to the educational use of CAS technology, focusing on the unexpected complexity of instrumental genesis, mathematical needs of instrumentation, status of instrumented…

  5. To score or not to score: a qualitative study on GPs views on the use of instruments for depression.

    PubMed

    Pettersson, Agneta; Björkelund, Cecilia; Petersson, Eva-Lisa

    2014-04-01

    To improve the detection, diagnosis and follow-up of depression in primary care patients, it has been proposed that GPs should employ assessment instruments as a complement to the consultation. However, most GPs do not use such instruments routinely. To explore perceptions of Swedish GPs on the use of instruments in the medical consultation. Twenty-seven GPs discussed in five focus groups that were digitally recorded, transcribed verbatim and analysed by systematic text condensation. Six code groups emerged from the focus group discussions: (i) a perceived pressure from authorities and psychiatry to report depression scores; (ii) the scores were considered to be of limited value for the GP but could help the patient by facilitating sick leave compensation and hospitalization; (iii) instruments hampered the dialogue with the patient and non-verbal information was lost; (iv) the reliability of questionnaires was questioned; (v) instruments were seen as not fitting into primary care and GPs were uncertain how to use them and (vi) the main advantage of instruments was to promote communication with specific categories of patients. Using instruments to obtain a quantitative score of depression was of no benefit to the GPs. Given the weak evidence for the clinical relevance of many instruments, there is little reason to introduce them into practice. However, the instruments can facilitate communication with external actors and specific groups of patients.

  6. The Coherent X-ray Imaging instrument at the Linac Coherent Light Source

    DOE PAGES

    Liang, Mengning; Williams, Garth J.; Messerschmidt, Marc; ...

    2015-04-15

    The Coherent X-ray Imaging (CXI) instrument specializes in hard X-ray, in-vacuum, high power density experiments in all areas of science. Two main sample chambers, one containing a 100 nm focus and one a 1 µm focus, are available, each with multiple diagnostics, sample injection, pump–probe and detector capabilities. The flexibility of CXI has enabled it to host a diverse range of experiments, from biological to extreme matter.

  7. GMI Instrument Spin Balance Method, Optimization, Calibration, and Test

    NASA Technical Reports Server (NTRS)

    Ayari, Laoucet; Kubitschek, Michael; Ashton, Gunnar; Johnston, Steve; Debevec, Dave; Newell, David; Pellicciotti, Joseph

    2014-01-01

    The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3 year mission life. Therefore, GMI must be very precisely balanced about the spin axis and CG to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

  8. GMI Instrument Spin Balance Method, Optimization, Calibration and Test

    NASA Technical Reports Server (NTRS)

    Ayari, Laoucet; Kubitschek, Michael; Ashton, Gunnar; Johnston, Steve; Debevec, Dave; Newell, David; Pellicciotti, Joseph

    2014-01-01

    The Global Microwave Imager (GMI) instrument must spin at a constant rate of 32 rpm continuously for the 3-year mission life. Therefore, GMI must be very precisely balanced about the spin axis and center of gravity (CG) to maintain stable scan pointing and to minimize disturbances imparted to the spacecraft and attitude control on-orbit. The GMI instrument is part of the core Global Precipitation Measurement (GPM) spacecraft and is used to make calibrated radiometric measurements at multiple microwave frequencies and polarizations. The GPM mission is an international effort managed by the National Aeronautics and Space Administration (NASA) to improve climate, weather, and hydro-meteorological predictions through more accurate and frequent precipitation measurements. Ball Aerospace and Technologies Corporation (BATC) was selected by NASA Goddard Space Flight Center to design, build, and test the GMI instrument. The GMI design has to meet a challenging set of spin balance requirements and had to be brought into simultaneous static and dynamic spin balance after the entire instrument was already assembled and before environmental tests began. The focus of this contribution is on the analytical and test activities undertaken to meet the challenging spin balance requirements of the GMI instrument. The novel process of measuring the residual static and dynamic imbalances with a very high level of accuracy and precision is presented together with the prediction of the optimal balance masses and their locations.

  9. Development of ACLEEM questionnaire, an instrument measuring residents' educational environment in postgraduate ambulatory setting.

    PubMed

    Riquelme, Arnoldo; Padilla, Oslando; Herrera, Cristian; Olivos, Trinidad; Román, José Antonio; Sarfatis, Alberto; Solís, Nancy; Pizarro, Margarita; Torres, Patricio; Roff, Sue

    2013-01-01

    Students' perceptions of their educational environment (EE) have been studied in undergraduate and postgraduate curricula. Postgraduate EE has been measured in hospital settings. However, there are no instruments available to measure the EE in postgraduate ambulatory settings. The aim of this study was to develop the "ambulatory care learning education environment measure" (ACLEEM). A mixed methodology was used including three stages: (1) Grounded theory (focus groups); (2) Delphi technique to identify consensus; and (3) Pilot study. Three quota samples of approximately 60 stakeholders were formed, one as focus groups and two as Delphi panels. Eight focus groups were carried out including 58 residents (Latin-American Spanish speakers). The results were analysed and 173 items were offered to a National Delphi panel (61 residents and teachers). They reduced in two rounds the number of important items to 54. The 54-item questionnaire was then piloted with 63 residents and refined to the final version of the ACLEEM with 50 items and three domains. The 50-item inventory is a valid instrument to measure the EE in postgraduate ambulatory setting in Chile. Large-scale administration of the ACLEEM questionnaire to evaluate its construct validity and reliability are the next steps to test the psychometric properties of the instrument.

  10. SPICE: An innovative, flexible instrument concept

    NASA Technical Reports Server (NTRS)

    Nishioka, Kenji; Cauffman, D. P.; Jurcevich, B.; Mendez, David J.; Ryder, James T.

    1994-01-01

    Studies and plans for orbital capture of cosmic dust and interplanetary dust particles (IDP's) looked very bright with the advent of space station Freedom (SSF) and formal selection of Cosmic Dust Collection Facility (CDCF) as an attached payload in 1990. Unfortunately it has been downhill since its selection, culminating in CDCF being dropped as attached payload in the SSF redesign process this year. This action was without any input from the science or cosmic dust communities. The Exobiology Intact Capture Experiment (Exo-ICE) as an experiment on CDCF was also lost. Without CDCF, no facility-class instrument for cosmic dust studies is available or planned. When CDCF (and Exo-ICE) was selected as a SSF attached payload, an exercise called the small particle intact capture experiment (SPICE) was started for Exo-ICE to develop an understanding and early testing of the necessary expertise and technology for intact capture of cosmic dust and IDP's. This SPICE activity looks to fly small, meter square or less, collection area experiments on early orbital platforms of opportunity such as EURECA, MIR, WESTAR, and others, including the shuttle. The SPICE activity has focused on developing techniques and instrument concepts to capture particles intact and without inadvertent contamination. It began with a survey and screening of available capture media concepts and then focused on the development of a capture medium that can meet these requirements. Evaluation and development of the chosen capture medium, aerogel (a silicon oxide gel), has so far lived up to the expectations of meeting the requirements and is highlighted in a companion paper at this workshop. Others such as McDonnell's Timeband Capture Cell Experiment (TICCE) on EuReCa and Tsuo's GAS-CAN lid experiments on STS 47 and 57 have flown aerogel, but without addressing the contamination issue/requirement, especially regarding organics. Horz, Zolenskym and others have studied and have also been advocates for its

  11. Mars Miniature Science Instruments

    NASA Technical Reports Server (NTRS)

    Kim, Soon Sam; Hayati, Samad; Lavery, David; McBrid, Karen

    2006-01-01

    For robotic Mars missions, all the science information is gathered through on-board miniature instruments that have been developed through many years of R&D. Compared to laboratory counterparts, the rover instruments require miniaturization, such as low mass (1-2 kg), low power (> 10 W) and compact (1-2 liter), yet with comparable sensitivity. Since early 1990's, NASA recognized the need for the miniature instruments and launched several instrument R&D programs, e.g., PIDDP (Planetary Instrument Definition and Development). However, until 1998, most of the instrument R&D programs supported only up to a breadboard level (TRL 3, 4) and there is a need to carry such instruments to flight qualifiable status (TU 5, 6) to respond to flight AOs (Announcement of Opportunity). Most of flight AOs have only limited time and financial resources, and can not afford such instrument development processes. To bridge the gap between instrument R&D programs and the flight instrument needs, NASA's Mars Technology Program (MTP) created advanced instrumentation program, Mars Instrument Development Project (MIDP). MIDP candidate instruments are selected through NASA Research Announcement (NRA) process [l]. For example, MIDP 161998-2000) selected and developed 10 instruments, MIDP II (2003-2005) 16 instruments, and MIDP III (2004-2006) II instruments.Working with PIs, JPL has been managing the MIDP tasks since September 1998. All the instruments being developed under MIDP have been selected through a highly competitive NRA process, and employ state-of-the-art technology. So far, four MIDP funded instruments have been selected by two Mars missions (these instruments have further been discussed in this paper).

  12. Design, development, and testing of the DCT Cassegrain instrument support assembly

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Dunham, Edward W.; Nye, Ralph A.; Chylek, Tomas; Oliver, Richard C.

    2012-09-01

    The 4.3m Discovery Channel Telescope delivers an f/6.1 unvignetted 0.5° field to its RC focal plane. In order to support guiding, wavefront sensing, and instrument installations, a Cassegrain instrument support assembly has been developed which includes a facility guider and wavefront sensor package (GWAVES) and multiple interfaces for instrumentation. A 2-element, all-spherical, fused-silica corrector compensates for field curvature and astigmatism over the 0.5° FOV, while reducing ghost pupil reflections to minimal levels. Dual roving GWAVES camera probes pick off stars in the outer annulus of the corrected field, providing simultaneous guiding and wavefront sensing for telescope operations. The instrument cube supports 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. The corrected beam passes through a dual filter wheel before imaging with the 6K x 6K single CCD of the Large Monolithic Imager (LMI). We describe key development strategies for the DCT Cassegrain instrument assembly and GWAVES, including construction of a prime focus test assembly with wavefront sensor utilized in fall 2011 to begin characterization of the DCT primary mirror support. We also report on 2012 on-sky test results of wavefront sensing, guiding, and imaging with the integrated Cassegrain cube.

  13. First Images from the Focusing Optics X-Ray Solar Imager

    NASA Astrophysics Data System (ADS)

    Krucker, Säm; Christe, Steven; Glesener, Lindsay; Ishikawa, Shin-nosuke; Ramsey, Brian; Takahashi, Tadayuki; Watanabe, Shin; Saito, Shinya; Gubarev, Mikhail; Kilaru, Kiranmayee; Tajima, Hiroyasu; Tanaka, Takaaki; Turin, Paul; McBride, Stephen; Glaser, David; Fermin, Jose; White, Stephen; Lin, Robert

    2014-10-01

    The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload flew for the first time on 2012 November 2, producing the first focused images of the Sun above 5 keV. To enable hard X-ray (HXR) imaging spectroscopy via direct focusing, FOXSI makes use of grazing-incidence replicated optics combined with fine-pitch solid-state detectors. On its first flight, FOXSI observed several targets that included active regions, the quiet Sun, and a GOES-class B2.7 microflare. This Letter provides an introduction to the FOXSI instrument and presents its first solar image. These data demonstrate the superiority in sensitivity and dynamic range that is achievable with a direct HXR imager with respect to previous, indirect imaging methods, and illustrate the technological readiness for a spaceborne mission to observe HXRs from solar flares via direct focusing optics.

  14. Instrument Development of Real Time Holographic Water Drop Size Measurement System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Springston, Stephen

    2007-02-09

    BNL participated with multiple correspondences with Physical Optics Corporation (POC) on the design considerations of an airbome instrument. A pod for extemal deployment ofthe POC unit on the DOE Research Aircraft Facility (RAF), an instrumented, Grumman G-1 aircraft was loaned to POC. BNL proposed evaluation flight tests between the POC unit and the BNL Cloud Aerosol Probe Spectrometer (CAPS) as a reference method. BNL's involvement is described in the semi-annual report ofPOC to DOE. Because of unanticipated technical and engineering difficulties, POC was unable to fit their instrument into an aircraft pod. As a result they are now focusing onmore » a ground-based version first. A prototype laboratory version of the Real-Time Holographic Water Drop Size Measurement (WDSM) System has been constructed.« less

  15. On-ground tests of the NISP infrared spectrometer instrument for Euclid

    NASA Astrophysics Data System (ADS)

    Jomni, Cyril; Ealet, Anne; Gillard, William; Prieto, Éric; Grupp, Frank U.

    2017-09-01

    Euclid is an ESA mission dedicated to understand the acceleration of the expansion of the Universe. The mission will measure hundred of millions of galaxies in spectrophotometry and photometry in the near infrared thanks to a spectro-photometer called NISP. This instrument will be assembled and tested in Marseille. To prepare the on-ground test plan and develop the test procedure, we have used simulated PSF images, based on a Zemax optical design of the instrument. We have developed the analysis tools that will be further used to build the procedure verification. We present here the method and analysis results to adjust the focus of the instrument. We will in particular show that because of the sampling of the PSF, a dithering strategy should be adapted and will constraint the development of the test plan.

  16. Design and development status of the University of Tokyo Atacama Observatory 6.5m telescope

    NASA Astrophysics Data System (ADS)

    Morokuma, Tomoki; Aoki, Tsutomu; Doi, Mamoru; Handa, Toshihiro; Kamizuka, Takafumi; Kato, Natsuko; Kawara, Kimiaki; Kohno, Kotaro; Konishi, Masahiro; Koshida, Shintaro; Minezaki, Takeo; Miyata, Takashi; Motohara, Kentaro; Sako, Shigeyuki; Soyano, Takao; Takahashi, Hidenori; Tamura, Yoichi; Tanabe, Toshihiko; Tanaka, Masuo; Tarusawa, Ken'ichi; Yoshii, Yuzuru

    2014-07-01

    We here summarize the design and the current fabrication status for the University of Tokyo Atacama Observatory (TAO) 6.5-m telescope. The TAO telescope is operated at one of the best sites for infrared observations, at the summit of Co. Chajnantor in Chile, and is optimized for infrared observations. The telescope mount, mirrors, and mirror support systems are now at the final design phase. The mechanical and optical designs are done by following and referring to those of the Magellan telescopes, MMT, and Large Binocular Telescope. The final focal ratio is 12.2. The field-of-view is as wide as 25 arcmin in diameter and the plate scale is 2.75 arcsec mm-1. The F/1.25 light-weighted borosilicate (Ohara E6) honeycomb primary mirror is adopted and being fabricated by the Steward Observatory Mirror Laboratory. The primary mirror is supported by 104 loadspreaders bonded to the back surface of the mirror and 6 adjustable hardpoints. The mirror is actively controlled by adjusting the actuator forces based on the realtime wavefront measurement. The actuators are optimized for operation at high altitude of the site, 5640-m above the sea level, by considering the low temperature and low air pressure. The mirror is held in the primary mirror cell which is used as a part of the vacuum chamber when the mirror surface is aluminized without being detached from the cell. The pupil is set at the secondary mirror to minimize infrared radiation into instruments. The telescope has two Nasmyth foci for near-infrared and mid-infrared facility instruments (SWIMS and MIMIZUKU, respectively) and one folded-Caseggrain focus for carry-in instruments. At each focus, autoguider and wavefront measurement systems are attached to achieve seeing-limited image quality. The telescope mount is designed as a tripod-disk type alt-azimuth mount. Both the azimuthal and elevation axes are supported by and run on the hydrostatic bearings. Friction drives are selected for these axis drives. The telescope

  17. Development and Validation of an Instrument to Measure University Students' Biotechnology Attitude

    NASA Astrophysics Data System (ADS)

    Erdogan, Mehmet; Özel, Murat; Uşak, Muhammet; Prokop, Pavol

    2009-06-01

    The impact of biotechnologies on peoples' everyday lives continuously increases. Measuring young peoples' attitudes toward biotechnologies is therefore very important and its results are useful not only for science curriculum developers and policy makers, but also for producers and distributors of genetically modified products. Despite of substantial number of instruments which focused on measuring student attitudes toward biotechnology, a majority of them were not rigorously validated. This study deals with the development and validation of an attitude questionnaire toward biotechnology. Detailed information on development and validation process of the instrument is provided. Data gathered from 326 university students provided evidence for the validity and reliability of the new instrument which consists of 28 attitude items on a five point likert type scale. It is believed that the instrument will serve as a valuable tool for both instructors and researchers in science education to assess students' biotechnology attitudes.

  18. Tools of the Trade: Microcomputer-Based Instrumentation: As Easy As ADC.

    ERIC Educational Resources Information Center

    Lam, Tom

    1983-01-01

    Provides a brief introduction to using the microcomputer as a piece of laboratory equipment. Focuses on the range of hardware currently available to assist microcomputer-based-instrumentation (MBI), specifically the analog-to-digital converters. In addition, discusses specification of system performance, selection and integration of components,…

  19. Development of an instrument to understand the child protective services decision-making process, with a focus on placement decisions.

    PubMed

    Dettlaff, Alan J; Christopher Graham, J; Holzman, Jesse; Baumann, Donald J; Fluke, John D

    2015-11-01

    When children come to the attention of the child welfare system, they become involved in a decision-making process in which decisions are made that have a significant effect on their future and well-being. The decision to remove children from their families is particularly complex; yet surprisingly little is understood about this decision-making process. This paper presents the results of a study to develop an instrument to explore, at the caseworker level, the context of the removal decision, with the objective of understanding the influence of the individual and organizational factors on this decision, drawing from the Decision Making Ecology as the underlying rationale for obtaining the measures. The instrument was based on the development of decision-making scales used in prior decision-making studies and administered to child protection caseworkers in several states. Analyses included reliability analyses, principal components analyses, and inter-correlations among the resulting scales. For one scale regarding removal decisions, a principal components analysis resulted in the extraction of two components, jointly identified as caseworkers' decision-making orientation, described as (1) an internal reference to decision-making and (2) an external reference to decision-making. Reliability analyses demonstrated acceptable to high internal consistency for 9 of the 11 scales. Full details of the reliability analyses, principal components analyses, and inter-correlations among the seven scales are discussed, along with implications for practice and the utility of this instrument to support the understanding of decision-making in child welfare. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. The Characterization of Biosignatures in Caves Using an Instrument Suite

    NASA Astrophysics Data System (ADS)

    Uckert, Kyle; Chanover, Nancy J.; Getty, Stephanie; Voelz, David G.; Brinckerhoff, William B.; McMillan, Nancy; Xiao, Xifeng; Boston, Penelope J.; Li, Xiang; McAdam, Amy; Glenar, David A.; Chavez, Arriana

    2017-12-01

    The search for life and habitable environments on other Solar System bodies is a major motivator for planetary exploration. Due to the difficulty and significance of detecting extant or extinct extraterrestrial life in situ, several independent measurements from multiple instrument techniques will bolster the community's confidence in making any such claim. We demonstrate the detection of subsurface biosignatures using a suite of instrument techniques including IR reflectance spectroscopy, laser-induced breakdown spectroscopy, and scanning electron microscopy/energy dispersive X-ray spectroscopy. We focus our measurements on subterranean calcium carbonate field samples, whose biosignatures are analogous to those that might be expected on some high-interest astrobiology targets. In this work, we discuss the feasibility and advantages of using each of the aforementioned instrument techniques for the in situ search for biosignatures and present results on the autonomous characterization of biosignatures using multivariate statistical analysis techniques.

  1. A Modular Instrumentation System for NASA's Habitat Demonstration Unit

    NASA Technical Reports Server (NTRS)

    Rojdev, Kristina; Kennedy, Kriss; Yim, Hester; Wagner, Raymond S.; Hong, Todd; Studor, George; Delaune, Paul

    2010-01-01

    NASA's human spaceflight program is focused on developing technologies to expand the reaches of human exploration and science activities beyond low earth orbit. A critical aspect of living in space or on planetary surfaces is habitation, which provides a safe and comfortable space in which humans can live and work. NASA is seeking out the best option for habitation by exploring several different concepts through the Habitat Demonstration Unit (HDU) project. The purpose of this HDU is to develop a fully autonomous habitation system that enables human exploration of space. One critical feature of the HDU project that helps to accomplish its mission of autonomy is the instrumentation system that monitors key subsystems operating within a Habitat configuration. The following paper will discuss previous instrumentation systems used in analog habitat concepts and how the current instrumentation system being implemented on the HDU1-PEM, or pressurized excursion module, is building upon the lessons learned of those previous systems. Additionally, this paper will discuss the benefits and the limitations of implementing a wireless sensor network (WSN) as the basis for data transport in the instrumentation system. Finally, this paper will address the experiences and lessons learned with integration, testing prior to deployment, and field testing at the JSC rock yard. NASA is developing the HDU1-PEM as a step towards a fully autonomous habitation system that enables human exploration of space. To accomplish this purpose, the HDU project is focusing on development, integration, testing, and evaluation of habitation systems. The HDU will be used as a technology pull, testbed, and integration environment in which to advance NASA's understanding of alternative mission architectures, requirements, and operations concepts definition and validation. This project is a multi-year effort. In 2010, the HDU1-PEM will be in a pressurized excursion module configuration, and in 2011 the

  2. Conduction cooled compact laser for chemcam instrument

    NASA Astrophysics Data System (ADS)

    Faure, B.; Saccoccio, M.; Maurice, S.; Durand, E.; Derycke, C.

    2017-11-01

    A new conduction cooled compact laser for Laser Induced Breakdown Spectroscopy (LIBS) on Mars is presented. The laser provides pulses with energy higher than 30mJ at 1μm of wavelength with a good spatial quality. Three development prototypes of this laser have been built and functional and environmental tests have been done. Then, the Qualification and Flight models have been developed and delivered. A spare model is now developed. This laser will be mounted on the ChemCam Instrument of the NASA mission MSL 2009. ChemCam Instrument is developed in collaboration between France (CESR and CNES) and USA (LANL). The goal of this Instrument is to study the chemical composition of Martian rocks. A laser source (subject of this presentation) emits a pulse which is focused by a telescope. It creates a luminous plasma on the rock; the light of this plasma is then analysed by three spectrometers to obtain information on the composition of the rock. The laser source is developed by the French company Thales Laser, with a technical support from CNES and CESR. This development is funded by CNES. The laser is compact, designed to work in burst mode. It doesn't require any active cooling.

  3. Aeronautic instruments. Section I : general classification of instruments and problems including bibliography

    NASA Technical Reports Server (NTRS)

    Hersey, Mayo D

    1923-01-01

    This report is intended as a technical introduction to the series of reports on aeronautic instruments. It presents a discussion of those subjects which are common to all instruments. First, a general classification is given, embracing all types of instruments used in aeronautics. Finally, a classification is given of the various problems confronted by the instrument expert and investigator. In this way the following groups of problems are brought up for consideration: problems of mechanical design, human factor, manufacturing problems, supply and selection of instruments, problems concerning the technique of testing, problems of installation, problems concerning the use of instruments, problems of maintenance, and physical research problems. This enumeration of problems which are common to instruments in general serves to indicate the different points of view which should be kept in mind in approaching the study of any particular instrument.

  4. The Discovery Channel Telescope: Construction and Design Progress, January 2007

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Millis, R. L.; Smith, B. W.; Dunham, E. W.; Marshall, H.

    2006-12-01

    The Discovery Channel Telescope (DCT) is a 4.2m telescope under construction in northern Arizona. The DCT is located at a new site near Happy Jack at 2361m elevation, which was selected following a lengthy site testing campaign that demonstrated DIMM-characterized median ground-level seeing of 0.84-arcsec FWHM. The DCT science mission includes targeted studies of astrophysical and solar system objects utilizing RC and Nasmyth-mounted imaging and spectroscopic instrumentation, and wide-field surveys of KBO’s, NEA’s, and astrophysical objects with a 2-degree FOV prime focus camera. The DCT facility enclosure and control buildings will be completed soon, including the telescope mount and dome supports, major machinery infrastructure, the instrument laboratory, control and computer rooms, and the auxiliary building for the mirror coating plant. Meanwhile, the effort for final figuring and polishing of the 4.3m ULE meniscus primary mirror blank began in August 2006 at the University of Arizona College of Optical Sciences. The primary mirror and its design support, and the integrated telescope mount model, were finite-element analyzed to optimize the design of the mirror and top-end support configurations. The primary mirror axial and tangential actuators will be fabricated in early 2007 and utilized in the final figure and polish cycle. The prime focus camera design has been refined to achieve atmospheric dispersion-compensated 0.25-arcsec images at 1-degree field radius, from B to I-band, at reduced cost through simplification of glasses to standard types and utilization of spheres on all but two lens surfaces. The Discovery Channel Telescope is a project of the Lowell Observatory with major financial support from Discovery Communications, Inc. (DCI). DCI plans ongoing television programming featuring the construction of the telescope and the research ultimately conducted with the DCT. Lowell Observatory and Discovery Communications are actively seeking additional

  5. Review of manual control methods for handheld maneuverable instruments.

    PubMed

    Fan, Chunman; Dodou, Dimitra; Breedveld, Paul

    2013-06-01

    By the introduction of new technologies, surgical procedures have been varying from free access in open surgery towards limited access in minimal access surgery. Improving access to difficult-to-reach anatomic sites, e.g. in neurosurgery or percutaneous interventions, needs advanced maneuverable instrumentation. Advances in maneuverable technology require the development of dedicated methods enabling surgeons to stay in direct, manual control of these complex instruments. This article gives an overview of the state-of-the-art in the development of manual control methods for handheld maneuverable instruments. It categorizes the manual control methods in three levels: a) number of steerable segments, b) number of Degrees Of Freedom (DOF), and c) coupling between control motion of the handle and steering motion of the tip. The literature research was completed by using Web of Science, Scopus and PubMed. The study shows that in controlling single steerable segments, direct as well as indirect control methods have been developed, whereas in controlling multiple steerable segments, a gradual shift can be noticed from parallel and serial control to integrated control. The development of multi-segmented maneuverable instruments is still at an early stage, and an intuitive and effective method to control them has to become a primary focus in the domain of minimal access surgery.

  6. Mineralogy and Astrobiology Detection Using Laser Remote Sensing Instrument

    NASA Technical Reports Server (NTRS)

    Abedin, M. Nurul; Bradley, Arthur T.; Sharma, Shiv K.; Misra, Anupam K.; Lucey, Paul G.; Mckay, Chistopher P.; Ismail, Syed; Sandford, Stephen P.

    2015-01-01

    A multispectral instrument based on Raman, laser-induced fluorescence (LIF), laser-induced breakdown spectroscopy (LIBS), and a lidar system provides high-fidelity scientific investigations, scientific input, and science operation constraints in the context of planetary field campaigns with the Jupiter Europa Robotic Lander and Mars Sample Return mission opportunities. This instrument conducts scientific investigations analogous to investigations anticipated for missions to Mars and Jupiter's icy moons. This combined multispectral instrument is capable of performing Raman and fluorescence spectroscopy out to a >100 m target distance from the rover system and provides single-wavelength atmospheric profiling over long ranges (>20 km). In this article, we will reveal integrated remote Raman, LIF, and lidar technologies for use in robotic and lander-based planetary remote sensing applications. Discussions are focused on recently developed Raman, LIF, and lidar systems in addition to emphasizing surface water ice, surface and subsurface minerals, organics, biogenic, biomarker identification, atmospheric aerosols and clouds distributions, i.e., near-field atmospheric thin layers detection for next robotic-lander based instruments to measure all the above-mentioned parameters. OCIS codes: (120.0280) Remote sensing and sensors; (130.0250) Optoelectronics; (280.3640) Lidar; (300.2530) Fluorescence, laser-induced; (300.6450) Spectroscopy, Raman; (300.6365) Spectroscopy, laser induced breakdown

  7. FIRST IMAGES FROM THE FOCUSING OPTICS X-RAY SOLAR IMAGER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krucker, Säm; Glesener, Lindsay; Turin, Paul

    2014-10-01

    The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload flew for the first time on 2012 November 2, producing the first focused images of the Sun above 5 keV. To enable hard X-ray (HXR) imaging spectroscopy via direct focusing, FOXSI makes use of grazing-incidence replicated optics combined with fine-pitch solid-state detectors. On its first flight, FOXSI observed several targets that included active regions, the quiet Sun, and a GOES-class B2.7 microflare. This Letter provides an introduction to the FOXSI instrument and presents its first solar image. These data demonstrate the superiority in sensitivity and dynamic range that is achievable with amore » direct HXR imager with respect to previous, indirect imaging methods, and illustrate the technological readiness for a spaceborne mission to observe HXRs from solar flares via direct focusing optics.« less

  8. Identifying the Barriers to Using Games and Simulations in Education: Creating a Valid and Reliable Survey Instrument

    ERIC Educational Resources Information Center

    Justice, Lenora Jean

    2012-01-01

    The purpose of this study was to create a valid and reliable instrument to measure teacher perceived barriers to the adoption of games and simulations in instruction. Previous research, interviews with educators, a focus group, an expert review, and a think aloud protocol were used to design a survey instrument. After finalization, the survey was…

  9. Designing Spatial Visualisation Tasks for Middle School Students with a 3D Modelling Software: An Instrumental Approach

    ERIC Educational Resources Information Center

    Turgut, Melih; Uygan, Candas

    2015-01-01

    In this work, certain task designs to enhance middle school students' spatial visualisation ability, in the context of an instrumental approach, have been developed. 3D modelling software, SketchUp®, was used. In the design process, software tools were focused on and, thereafter, the aim was to interpret the instrumental genesis and spatial…

  10. Identifying instruments to quantify financial management skills in adults with acquired cognitive impairments.

    PubMed

    Engel, Lisa; Bar, Yael; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2016-01-01

    Financial management skills-that is, the skills needed to handle personal finances such as banking and paying bills-are essential to a person's autonomy, independence, and community living. To date, no comprehensive review of financial management skills instruments exists, making it difficult for clinicians and researchers to choose relevant instruments. The objectives of this review are to: (a) identify all available instruments containing financial management skill items that have been used with adults with acquired cognitive impairments; (b) categorize the instruments by source (i.e., observation based, self-report, proxy report); and (c) describe observation-based performance instruments by populations, overarching concepts measured, and comprehensiveness of financial management items. Objective (c) focuses on observation-based performance instruments as these measures can aid in situations where the person with cognitive impairment has poor self-awareness or where the proxy has poor knowledge of the person's current abilities. Two reviewers completed two systematic searches of five databases. Instruments were categorized by reviewing published literature, copies of the instruments, and/or communication with instrument authors. Comprehensiveness of items was based on nine key domains of financial management skills developed by the authors. A total of 88 discrete instruments were identified. Of these, 44 were categorized as observation-based performance and 44 as self- and/or proxy-reports. Of the 44 observation-based performance instruments, 8 had been developed for acquired brain injury populations and 24 for aging and dementia populations. Only 7 of the observation-based performance instruments had items spanning 6 or more of the 9 financial management skills domains. The majority of instruments were developed for aging and dementia populations, and few were comprehensive. This review provides foundation for future instrument psychometric and clinimetric

  11. VIRUS instrument enclosures

    NASA Astrophysics Data System (ADS)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  12. The COSPIX Mission: Focusing on the Energetic and Obscured Universe

    NASA Technical Reports Server (NTRS)

    Ferrando, P.; Goldwurm, A.; Laurent, P.; Limousin, O.; Beckmann, V; Arnaud, M.; Barcons, X.; Bomans, D.; Caballero, I.; Carrera, F.; hide

    2010-01-01

    Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of its call for selection of the M3 mission. In addition, COSPIX, will also provide key measurements on the non thermal Universe, particularly in relation to the question of the acceleration of particles, as well as on many other fundamental questions as for example the energetic particle content of clusters of galaxies. COSPIX is proposed as an observatory operating from 0.3 to more than 100 keV. The payload features a single long focal length focusing telescope offering an effective area close to ten times larger than any scheduled focusing mission at 30 keV, an angular resolution better than 20 arcseconds in hard X-rays, and polarimetric capabilities within the same focal plane instrumentation. In this paper, we describe the science objectives of the mission, its baseline design, and its performances, as proposed to ESA.

  13. Development of instrument for assessing students’ critical and creative thinking ability

    NASA Astrophysics Data System (ADS)

    Herpiana, R.; Rosidin, U.

    2018-01-01

    The purpose of this study was to develop instruments to measure critical thinking ability and creative students in the topics of physics simple harmonic motion. The research method used was research development with application of procedures including research and data collection, planning, and initial product development. The participants of the study were thirty-four tenth grade students and five physics teachers of physics who were selected randomly from schools in the province of Lampung. The data collected by using test and analyzed in quantitative descriptive. Initial data showed that students’ critical and creative thinking ability were still low and instruments to assess students’ critical thinking skills and creative students was not yet available. Most of assessment conducted focused on memorization. Thus, the researchers developed a draft of instrument in the form of the test description based on criteria that encouraged students’ activity in understanding the concepts, strategies and decision/solution in dealing with problems. The development of the instrument was conducted considering real-world phenomena in the form of pictures and stories, description of the situation, and verbal presentation.

  14. Instruments as Empirical Evidence for the Analysis of Higher Education Policies

    ERIC Educational Resources Information Center

    Reale, Emanuela; Seeber, Marco

    2013-01-01

    This paper focuses on policy implementation in Higher Education (HE) analysed through the evolution and transformation of policy instruments related to government funding and evaluation. We investigate how steering and governance tools have been put into action, in order to analyse how original policy rationales and justifications have evolved and…

  15. TOGA - A GNSS Reflections Instrument for Remote Sensing Using Beamforming

    NASA Technical Reports Server (NTRS)

    Esterhuizen, S.; Meehan, T. K.; Robison, D.

    2009-01-01

    Remotely sensing the Earth's surface using GNSS signals as bi-static radar sources is one of the most challenging applications for radiometric instrument design. As part of NASA's Instrument Incubator Program, our group at JPL has built a prototype instrument, TOGA (Time-shifted, Orthometric, GNSS Array), to address a variety of GNSS science needs. Observing GNSS reflections is major focus of the design/development effort. The TOGA design features a steerable beam antenna array which can form a high-gain antenna pattern in multiple directions simultaneously. Multiple FPGAs provide flexible digital signal processing logic to process both GPS and Galileo reflections. A Linux OS based science processor serves as experiment scheduler and data post-processor. This paper outlines the TOGA design approach as well as preliminary results of reflection data collected from test flights over the Pacific ocean. This reflections data demonstrates observation of the GPS L1/L2C/L5 signals.

  16. The Characterization of Biosignatures in Caves Using an Instrument Suite.

    PubMed

    Uckert, Kyle; Chanover, Nancy J; Getty, Stephanie; Voelz, David G; Brinckerhoff, William B; McMillan, Nancy; Xiao, Xifeng; Boston, Penelope J; Li, Xiang; McAdam, Amy; Glenar, David A; Chavez, Arriana

    2017-12-01

    The search for life and habitable environments on other Solar System bodies is a major motivator for planetary exploration. Due to the difficulty and significance of detecting extant or extinct extraterrestrial life in situ, several independent measurements from multiple instrument techniques will bolster the community's confidence in making any such claim. We demonstrate the detection of subsurface biosignatures using a suite of instrument techniques including IR reflectance spectroscopy, laser-induced breakdown spectroscopy, and scanning electron microscopy/energy dispersive X-ray spectroscopy. We focus our measurements on subterranean calcium carbonate field samples, whose biosignatures are analogous to those that might be expected on some high-interest astrobiology targets. In this work, we discuss the feasibility and advantages of using each of the aforementioned instrument techniques for the in situ search for biosignatures and present results on the autonomous characterization of biosignatures using multivariate statistical analysis techniques. Key Words: Biosignature suites-Caves-Mars-Life detection. Astrobiology 17, 1203-1218.

  17. Evaluation of Experimental Data from the Gains Balloon GPS Surface Reflection Instrument

    NASA Technical Reports Server (NTRS)

    Ganoe, George G.; Johnson, Thomas A.; Somero, John Ryan

    2002-01-01

    The GPS Surface Reflection Instrument was integrated as an experiment on the GAINS (Global Airocean IN-situ System) 48-hour balloon mission flown in June 2002. The data collected by similar instruments in the past has been used to measure sea state from which ocean surface winds can be accurately estimated. The GPS signal has also been shown to be reflected from wetland areas and even from subsurface moisture. The current version of the instrument has been redesigned to be more compact, use less power, and withstand a greater variation in environmental conditions than previous versions. This instrument has also incorporated a new data collection mode to track 5 direct satellites (providing a continuous navigation solution) and multiplex the remaining 7 channels to track the reflected signal of the satellite tracked in channel 0. The new software mode has been shown to increase the signal to noise ratio of the collected data and enhance the science return of the instrument. During the GAINS balloon flight over the Northwest US, the instrument measured surface reflections as they were detected over the balloon's ground track. Since ground surface elevations in this area vary widely from the WGS-84 ellipsoid altitude, the instrument software has been modified to incorporate a surface altitude correction based on USGS 30-minute Digital Elevation Models. Information presented will include facts about instrument design goals, data collection methodologies and algorithms, and will focus on results of the science data analyses for the mission.

  18. Surgical treatment of pyogenic vertebral osteomyelitis with spinal instrumentation

    PubMed Central

    Chen, Wei-Hua; Jiang, Lei-Sheng

    2006-01-01

    Pyogenic vertebral osteomyelitis responds well to conservative treatment at early stage, but more complicated and advanced conditions, including mechanical spinal instability, epidural abscess formation, neurologic deficits, and refractoriness to antibiotic therapy, usually require surgical intervention. The subject of using metallic implants in the setting of infection remains controversial, although more and more surgeons acknowledge that instrumentation can help the body to combat the infection rather than to interfere with it. The combination of radical debridement and instrumentation has lots of merits such as, restoration and maintenance of the sagittal alignment of the spine, stabilization of the spinal column and reduction of bed rest period. This issue must be viewed in the context of the overall and detailed health conditions of the subjecting patient. We think the culprit for the recurrence of infection is not the implants itself, but is the compromised general health condition of the patients. In this review, we focus on surgical treatment of pyogenic vertebral osteomyelitis with special attention to the role of spinal instrumentation in the presence of pyogenic infection. PMID:17106664

  19. NASA Research For Instrument Approaches To Closely Spaced Parallel Runways

    NASA Technical Reports Server (NTRS)

    Elliott, Dawn M.; Perry, R. Brad

    2000-01-01

    Within the NASA Aviation Systems Capacity Program, the Terminal Area Productivity (TAP) Project is addressing airport capacity enhancements during instrument meteorological condition (IMC). The Airborne Information for Lateral Spacing (AILS) research within TAP has focused on an airborne centered approach for independent instrument approaches to closely spaced parallel runways using Differential Global Positioning System (DGPS) and Automatic Dependent Surveillance-Broadcast (ADS-B) technologies. NASA Langley Research Center (LaRC), working in partnership with Honeywell, Inc., completed in AILS simulation study, flight test, and demonstration in 1999 examining normal approaches and potential collision scenarios to runways with separation distances of 3,400 and 2,500 feet. The results of the flight test and demonstration validate the simulation study.

  20. The OCO-3 Mission: Science Objectives and Instrument Performance

    NASA Astrophysics Data System (ADS)

    Eldering, A.; Basilio, R. R.; Bennett, M. W.

    2017-12-01

    The Orbiting Carbon Observatory 3 (OCO-3) will continue global CO2 and solar-induced chlorophyll fluorescence (SIF) using the flight spare instrument from OCO-2. The instrument is currently being tested, and will be packaged for installation on the International Space Station (ISS) (launch readiness in early 2018.) This talk will focus on the science objectives, updated simulations of the science data products, and the outcome of recent instrument performance tests. The low-inclination ISS orbit lets OCO-3 sample the tropics and sub-tropics across the full range of daylight hours with dense observations at northern and southern mid-latitudes (+/- 52º). The combination of these dense CO2 and SIF measurements provides continuity of data for global flux estimates as well as a unique opportunity to address key deficiencies in our understanding of the global carbon cycle. The instrument utilizes an agile, 2-axis pointing mechanism (PMA), providing the capability to look towards the bright reflection from the ocean and validation targets. The PMA also allows for a snapshot mapping mode to collect dense datasets over 100km by 100km areas. Measurements over urban centers could aid in making estimates of fossil fuel CO2 emissions. Similarly, the snapshot mapping mode can be used to sample regions of interest for the terrestrial carbon cycle. In addition, there is potential to utilize data from ISS instruments ECOSTRESS (ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station) and GEDI (Global Ecosystem Dynamics Investigation), which measure other key variables of the control of carbon uptake by plants, to complement OCO-3 data in science analysis. In 2017, the OCO-2 instrument was transformed into the ISS-ready OCO-3 payload. The transformed instrument was thoroughly tested and characterized. Key characteristics, such as instrument ILS, spectral resolution, and radiometric performance will be described. Analysis of direct sun measurements taken during testing

  1. Development and Testing of Assessment Instruments for Multidisciplinary Engineering Capstone Design Courses

    ERIC Educational Resources Information Center

    Gerlick, Robert Edward

    2010-01-01

    The research presented in this manuscript was focused on the development of assessments for engineering design outcomes. The primary goal was to support efforts by the Transferrable Integrated Design Engineering Education (TIDEE) consortium in developing assessment instruments for multidisciplinary engineering capstone courses. Research conducted…

  2. Research Instrument Sharing

    ERIC Educational Resources Information Center

    Coulter, Charles L.

    1978-01-01

    Discusses the scientific and financial aspects of large instrument sharing in natural science areas from the point of view of instrument centers, users and funding agencies. Concludes that effective actions, with well-defined goals, must be implemented to solve the problems of instrument sharing. (GA)

  3. Science Instrument Sensitivities to Radioisotope Power System Environment

    NASA Technical Reports Server (NTRS)

    Bairstow, Brian; Lee, Young; Smythe, William; Zakrajsek, June

    2016-01-01

    system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.

  4. Analog-to-Digital Conversion to Accommodate the Dynamics of Live Music in Hearing Instruments

    PubMed Central

    Bahlmann, Frauke; Fulton, Bernadette

    2012-01-01

    Hearing instrument design focuses on the amplification of speech to reduce the negative effects of hearing loss. Many amateur and professional musicians, along with music enthusiasts, also require their hearing instruments to perform well when listening to the frequent, high amplitude peaks of live music. One limitation, in most current digital hearing instruments with 16-bit analog-to-digital (A/D) converters, is that the compressor before the A/D conversion is limited to 95 dB (SPL) or less at the input. This is more than adequate for the dynamic range of speech; however, this does not accommodate the amplitude peaks present in live music. The hearing instrument input compression system can be adjusted to accommodate for the amplitudes present in music that would otherwise be compressed before the A/D converter in the hearing instrument. The methodology behind this technological approach will be presented along with measurements to demonstrate its effectiveness. PMID:23258618

  5. Analog-to-digital conversion to accommodate the dynamics of live music in hearing instruments.

    PubMed

    Hockley, Neil S; Bahlmann, Frauke; Fulton, Bernadette

    2012-09-01

    Hearing instrument design focuses on the amplification of speech to reduce the negative effects of hearing loss. Many amateur and professional musicians, along with music enthusiasts, also require their hearing instruments to perform well when listening to the frequent, high amplitude peaks of live music. One limitation, in most current digital hearing instruments with 16-bit analog-to-digital (A/D) converters, is that the compressor before the A/D conversion is limited to 95 dB (SPL) or less at the input. This is more than adequate for the dynamic range of speech; however, this does not accommodate the amplitude peaks present in live music. The hearing instrument input compression system can be adjusted to accommodate for the amplitudes present in music that would otherwise be compressed before the A/D converter in the hearing instrument. The methodology behind this technological approach will be presented along with measurements to demonstrate its effectiveness.

  6. The Involvement Instrument.

    ERIC Educational Resources Information Center

    Roderick, Jessie A.

    The Involvement Instrument, an observational technique for examining children's interaction patterns and degree of involvement within the school setting, is presented in this paper. Training protocols for obtaining skill in using the Involvement Instrument, methods of analyzing data obtained by using the instrument, and criteria for determining…

  7. Cyclic Fatigue Resistance of Mtwo Rotary Instruments with two Different Instrumentation Techniques.

    PubMed

    de Menezes, Sílvio Emanuel Acioly Conrado; Machado Batista, Shirley; Brandão de Magalhães, Diego Felipe; Diana Santana, de Albuquerque; de Melo Monteiro, Gabriela Queiroz

    2018-01-01

    The objective of this in vitro study was to evaluate whether cervical preparation with Mtwo files in a crown-down technique influences instrumentation time and the cyclic fatigue resistance of these instruments. Two instrumentation techniques were evaluated (manufacturer and crown-down). Each group consisted of 10 kits containing four Mtwo instruments (10/0.04, 15/0.05, 20/0.06, and 25/0.06), which were used to prepare three standard simulated curved resin canals. The mean instrumentation time and the corresponding number of cycles for each instrumentation (NCI) were recorded. The instruments were rotated at a constant speed of 300 rpm in a stainless-steel canal (diameter of 1.5 mm) at a 90 ° angle of curvature and 5-mm radius. The center of the curvature was 5 mm from the tip of the instrument. The cyclic fatigue resistance of the files was determined by counting the number of cycles to failure (NCF). Data were analyzed by the Mann-Whitney test. The mean instrumentation time and NCI of files 10/0.04 and 15/0.05 were significantly lower ( P <0.05) when the crown-down technique was used compared to the manufacturer's method for the same tip size/taper file. There was no significant difference in the mean NCF between the two techniques. The crown-down technique did not interfere with resistance to cyclic fatigue. However, the shorter instrumentation time of files 10/0.04 and 15/0.05 could reduce the fracture risk in the case of reuse of these instruments.

  8. Racial/Ethnic Minority-Specific Instrumentation in Counseling Research: A Review, Critique, and Recommendations.

    ERIC Educational Resources Information Center

    Sabnani, Haresh B.; Ponterotto, Joseph G.

    1992-01-01

    Reviews eight instruments specifically conceptualized and developed for use in racial/ethnic minority-focused psychological research: Cultural Mistrust Inventory, African Self-Consciousness Scale, Cross-Cultural Counseling Inventory-Revised, Modern Racism Scale, Value Orientation Scale, Acculturation Rating Scale for Mexican Americans, Racial…

  9. Present status of aircraft instruments

    NASA Technical Reports Server (NTRS)

    1932-01-01

    This report gives a brief description of the present state of development and of the performance characteristics of instruments included in the following group: speed instruments, altitude instruments, navigation instruments, power-plant instruments, oxygen instruments, instruments for aerial photography, fog-flying instruments, general problems, summary of instrument and research problems. The items considered under performance include sensitivity, scale errors, effects of temperature and pressure, effects of acceleration and vibration, time lag, damping, leaks, elastic defects, and friction.

  10. Military Medical Leadership in Uniformed Medical Students: Creating a New Assessment Instrument Using the Delphi Method

    DTIC Science & Technology

    2015-12-17

    healthcare management and have not focused on assessing leadership among student physicians. A systematic review of 80 Delphi method studies by...medical students ( Research Question 1), to create a leadership assessment instrument based on those important components ( Research Question 2), and... research question 2 (RQ2) saw the creation of a three page assessment instrument to assess medical leadership in student physicians. Based on critical

  11. 76 FR 50997 - Application(s) for Duty-Free Entry of Scientific Instruments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ... DEPARTMENT OF COMMERCE International Trade Administration Application(s) for Duty-Free Entry of..., School of Earth Sciences, 275 Mendenhall Laboratory, 125 South Oval Mall, Columbus, OH 43210. Instrument... and high-contrast images, a stage that is easy to move, a focus that does not change with changing...

  12. Afterword: Instruments as media, media as instruments.

    PubMed

    Rheinberger, Hans-Jörg

    2016-06-01

    The collection of essays comes under the heading of two catchwords: instruments and media. This Afterword looks at their interaction and roles in exploring the characteristics of living beings throughout history, especially their melding and gliding into each other. Before turning to the papers, I will make some more general remarks on instruments and media in scientific, and in particular, biological research. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Surgical instrument similarity metrics and tray analysis for multi-sensor instrument identification

    NASA Astrophysics Data System (ADS)

    Glaser, Bernhard; Schellenberg, Tobias; Franke, Stefan; Dänzer, Stefan; Neumuth, Thomas

    2015-03-01

    A robust identification of the instrument currently used by the surgeon is crucial for the automatic modeling and analysis of surgical procedures. Various approaches for intra-operative surgical instrument identification have been presented, mostly based on radio-frequency identification (RFID) or endoscopic video analysis. A novel approach is to identify the instruments on the instrument table of the scrub nurse with a combination of video and weight information. In a previous article, we successfully followed this approach and applied it to multiple instances of an ear, nose and throat (ENT) procedure and the surgical tray used therein. In this article, we present a metric for the suitability of the instruments of a surgical tray for identification by video and weight analysis and apply it to twelve trays of four different surgical domains (abdominal surgery, neurosurgery, orthopedics and urology). The used trays were digitized at the central sterile services department of the hospital. The results illustrate that surgical trays differ in their suitability for the approach. In general, additional weight information can significantly contribute to the successful identification of surgical instruments. Additionally, for ten different surgical instruments, ten exemplars of each instrument were tested for their weight differences. The samples indicate high weight variability in instruments with identical brand and model number. The results present a new metric for approaches aiming towards intra-operative surgical instrument detection and imply consequences for algorithms exploiting video and weight information for identification purposes.

  14. The Instrumental Model

    ERIC Educational Resources Information Center

    Yeates, Devin Rodney

    2011-01-01

    The goal of this dissertation is to enable better predictive models by engaging raw experimental data through the Instrumental Model. The Instrumental Model captures the protocols and procedures of experimental data analysis. The approach is formalized by encoding the Instrumental Model in an XML record. Decoupling the raw experimental data from…

  15. Cyclic Fatigue Resistance of Mtwo Rotary Instruments with two Different Instrumentation Techniques

    PubMed Central

    de Menezes, Sílvio Emanuel Acioly Conrado; Machado Batista, Shirley; Brandão de Magalhães, Diego Felipe; Diana Santana, de Albuquerque; de Melo Monteiro, Gabriela Queiroz

    2018-01-01

    Introduction: The objective of this in vitro study was to evaluate whether cervical preparation with Mtwo files in a crown-down technique influences instrumentation time and the cyclic fatigue resistance of these instruments. Methods and Materials: Two instrumentation techniques were evaluated (manufacturer and crown-down). Each group consisted of 10 kits containing four Mtwo instruments (10/0.04, 15/0.05, 20/0.06, and 25/0.06), which were used to prepare three standard simulated curved resin canals. The mean instrumentation time and the corresponding number of cycles for each instrumentation (NCI) were recorded. The instruments were rotated at a constant speed of 300 rpm in a stainless-steel canal (diameter of 1.5 mm) at a 90° angle of curvature and 5-mm radius. The center of the curvature was 5 mm from the tip of the instrument. The cyclic fatigue resistance of the files was determined by counting the number of cycles to failure (NCF). Data were analyzed by the Mann-Whitney test. Results: The mean instrumentation time and NCI of files 10/0.04 and 15/0.05 were significantly lower (P<0.05) when the crown-down technique was used compared to the manufacturer’s method for the same tip size/taper file. There was no significant difference in the mean NCF between the two techniques. Conclusion: The crown-down technique did not interfere with resistance to cyclic fatigue. However, the shorter instrumentation time of files 10/0.04 and 15/0.05 could reduce the fracture risk in the case of reuse of these instruments. PMID:29692846

  16. Effects of Internal and External Focus of Attention on Novices' Rehearsal Evaluations

    ERIC Educational Resources Information Center

    Silvey, Brian A.; Montemayor, Mark

    2014-01-01

    The purpose of this study was to investigate the effects of internal and external focus of attention on novices' rehearsal evaluations. Thirty-two undergraduate instrumental music education students led bands in a series of three 6-minute rehearsals on their assigned excerpt. Prior to these rehearsals, participants were led in score study and…

  17. GPs’ opinions of health assessment instruments for people with intellectual disabilities: a qualitative study

    PubMed Central

    Bakker-van Gijssel, Esther J; Hartman, Tim C olde; Lucassen, Peter LBJ; van den Driessen Mareeuw, Francine; Dees, Marianne K; Assendelft, Willem JJ; van Schrojenstein Lantman-de Valk, Henny MJ

    2017-01-01

    Background GPs provide health care to people with intellectual disabilities (ID). People with ID find it difficult to express themselves concerning health-related matters. Applying health assessments is an effective method to reveal health needs, and can play a role in prevention and health promotion. Aim The aim of this qualitative study was to explore GPs’ considerations about applying a health assessment for people with ID. Design and setting This focus group study was conducted among a selection of Dutch GPs. Method An interview guide was developed. All discussions were audiorecorded and transcribed. Analysis was performed using the framework analysis approach. Two researchers independently applied open coding and identified a thematic framework. This framework and the summaries of views per theme were discussed in the research team. Results After four focus groups, with 23 GPs, saturation was reached. Three main themes evolved: health assessments in relation to GPs’ responsibility; the usefulness and necessity of health assessments; and barriers to using health assessments on people with ID. A health assessment instrument for people with ID can help GPs to focus on certain issues that are not so common in the general population. GPs are motivated to use such a tool if it is scientifically tested, and results in significant health gains. However, GPs identify barriers at the level of GP, patient, and organisation. Conclusion Most GPs in the focus groups consider providing medical care to people with ID their responsibility and indicate that a health assessment instrument could be a valuable tool. In order to deliver good care, they need education and support. Many barriers need to be overcome before a health assessment instrument can be implemented. PMID:27993898

  18. Instrumentation and control systems, equipment location; instrumentation and control building, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Instrumentation and control systems, equipment location; instrumentation and control building, instrumentation room, bays and console plan. Specifications No. Eng-04-353-55-72; drawing no. 60-09-12; sheet 110 of 148; file no. 1321/61. Stamped: Record drawing - as constructed. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA

  19. The Australian Longitudinal Study on Women's Health: Using Focus Groups to Inform Recruitment

    PubMed Central

    2016-01-01

    Background Recruitment and retention of participants to large-scale, longitudinal studies can be a challenge, particularly when trying to target young women. Qualitative inquiries with members of the target population can prove valuable in assisting with the development of effective recruiting techniques. Researchers in the current study made use of focus group methodology to identify how to encourage young women aged 18-23 to participate in a national cohort online survey. Objective Our objectives were to gain insight into how to encourage young women to participate in a large-scale, longitudinal health survey, as well as to evaluate the survey instrument and mode of administration. Methods The Australian Longitudinal Study on Women’s Health used focus group methodology to learn how to encourage young women to participate in a large-scale, longitudinal Web-based health survey and to evaluate the survey instrument and mode of administration. Nineteen groups, involving 75 women aged 18-23 years, were held in remote, regional, and urban areas of New South Wales and Queensland. Results Focus groups were held in 2 stages, with discussions lasting from 19 minutes to over 1 hour. The focus groups allowed concord to be reached regarding survey promotion using social media, why personal information was needed, strategies to ensure confidentiality, how best to ask sensitive questions, and survey design for ease of completion. Recruitment into the focus groups proved difficult: the groups varied in size between 1 and 8 participants, with the majority conducted with 2 participants. Conclusions Intense recruitment efforts and variation in final focus group numbers highlights the “hard to reach” character of young women. However, the benefits of conducting focus group discussions as a preparatory stage to the recruitment of a large cohort for a longitudinal Web-based health survey were upheld. PMID:26902160

  20. Seismic instrumentation of buildings

    USGS Publications Warehouse

    Çelebi, Mehmet

    2000-01-01

    The purpose of this report is to provide information on how and why we deploy seismic instruments in and around building structures. The recorded response data from buildings and other instrumented structures can be and are being primarily used to facilitate necessary studies to improve building codes and therefore reduce losses of life and property during damaging earthquakes. Other uses of such data can be in emergency response situations in large urban environments. The report discusses typical instrumentation schemes, existing instrumentation programs, the steps generally followed in instrumenting a structure, selection and type of instruments, installation and maintenance requirements and data retrieval and processing issues. In addition, a summary section on how recorded response data have been utilized is included. The benefits from instrumentation of structural systems are discussed.

  1. The Airborne Research Instrumentation Testing Opportunity (ARISTO)

    NASA Astrophysics Data System (ADS)

    Wolff, C.; Romashkin, P.; Lussier, L.; Baeuerle, B.; Stith, J. L.

    2016-12-01

    In 2015 the National Science Foundation (NSF) began a program to sponsor an annual flight campaign on one of its research aircraft (the C-130 and GV) operated by the National Center for Atmospheric Research (NCAR). The aircraft are managed by the Research Aviation Facility (RAF), which is part of the Earth Observing Laboratory (EOL) and responsible for planning and executing the campaigns. The purpose of this program, known as the Airborne Research Instrumentation Testing Opportunity or ARISTO, is to provide regular flight test opportunities for newly developed or highly modified instruments as part of their development effort. The NSF community has expressed a strong desire for regularly scheduled flight-testing programs to be able to test instrumentation, data systems, inlets, and software. ARISTO allows this testing in a low-pressure environment where any issues or problems will not affect the scientific goals of a large-scale field campaign. For this reason it is also a good experience for students who may be learning about the operation of an instrument or have not had previous exposure to a field project. They are also able to contribute to flight planning exercises and gain experience in acting as an instrument scientist during the program. A goal of the program is to incorporate students into the project operations to prepare the next generation of airborne researchers. ARISTO is conducted at the Research Aviation Facility at Rocky Mountain Metropolitan Airport in Broomfield, Colorado. The flight campaign consists of 20 flight hours, spread over three weeks. Flights are planned to allow the ARISTO participants to successfully test their instruments based on requirements they described in the initial application. Due to the limited hours most flights are focused in and around Colorado, though some have gone as far as Oklahoma and the Pacific Northwest to find the right conditions to meet testing requirements. Two ARISTO campaigns were successfully completed

  2. Validation of the ENVISAT atmospheric chemistry instruments

    NASA Astrophysics Data System (ADS)

    Snoeij, P.; Koopman, R.; Attema, E.; Zehner, C.; Wursteisen, P.; Dehn, A.; de Laurentius, M.; Frerick, J.; Mantovani, R.; Saavedra de Miguel, L.

    history: the GOMOS instrument operation has undergone an important change, and its processing chain is subject of two upgrades. For MIPAS intervention on one of the on-board subsystems has proven necessary, and an important data processing improvement cycle has been completed through reconfiguration of the processing chain. SCIAMACHY operations have required only minor interventions, and the presentation will focus on the processing chain evolution.

  3. Time Domain X-ray Astronomy with "All-Sky" Focusing Telescopes

    NASA Astrophysics Data System (ADS)

    Gorenstein, Paul

    2016-04-01

    The largest and most diverse types of temporal variations in all of astronomy occur in the soft, i.e. 0.5 to 10 keV, X-ray band. They range from millisecond QPO’s in compact binaries to year long flares from AGNs due to the absorption of a star by a SMBH, and the appearance of transient sources at decadal intervals. Models predict that at least some gravitational waves will be accompanied by an X-ray flare. A typical GRB produces more photons/sq. cm. in the soft band than it does in the Swift BAT 15 to 150 keV band. In addition the GRB X-ray fluence and knowledge of the details of the onset of the X-ray afterglow is obtained by observing the seamless transition from the active burst phase that has been attributed to internal shocks to the afterglow phases that has been attributed to external shocks. Detecting orphan X-ray afterglows will augment the event rate. With high sensitivity detectors some GRB identifications are likely to be with the youngest, most distant galaxies in the universe. Previous all-sky X-ray monitors have been non focusing limited field of view scanning instruments. An “All-Sky” (actually several ster FOV), focusing lobster-eye X-ray telescope will have much more grasp than the previous instruments and will allow a wide range of topics to be studied simultaneously. Two types of lobster-eye telescopes have been proposed. One type focuses in one dimension and uses a coded mask for resolution in the second. The other type focuses in two dimensions but has less effective area and less bandwidth. Both types are compatible with a Probe mission.

  4. Solid motor diagnostic instrumentation. [design of self-contained instrumentation

    NASA Technical Reports Server (NTRS)

    Nakamura, Y.; Arens, W. E.; Wuest, W. S.

    1973-01-01

    A review of typical surveillance and monitoring practices followed during the flight phases of representative solid-propellant upper stages and apogee motors was conducted to evaluate the need for improved flight diagnostic instrumentation on future spacecraft. The capabilities of the flight instrumentation package were limited to the detection of whether or not the solid motor was the cause of failure and to the identification of probable primary failure modes. Conceptual designs of self-contained flight instrumentation packages capable of meeting these reqirements were generated and their performance, typical cost, and unit characteristics determined. Comparisons of a continuous real time and a thresholded hybrid design were made on the basis of performance, mass, power, cost, and expected life. The results of this analysis substantiated the feasibility of a self-contained independent flight instrumentation module as well as the existence of performance margins by which to exploit growth option applications.

  5. Instrumental Relationships: A Potential Relational Model for Inner-City Youth Programs

    ERIC Educational Resources Information Center

    Halpern, Robert

    2005-01-01

    In this article, a distinct type of adult-youth relationship found in some youth programs and characterized as instrumental is discussed. Such relationships focus primarily on joint work on a task or project, or in a discipline, with the adult having expertise and a strong identity in the substantive domain involved, rather than in youth work per…

  6. A green observatory in the Chilean Atacama desert

    NASA Astrophysics Data System (ADS)

    Ramolla, Michael; Westhues, Christian; Hackstein, Moritz; Haas, Martin; Hodapp, Klaus; Lemke, Roland; Barr Domínguez, Angie; Chini, Rolf; Murphy, Miguel

    2016-08-01

    Since 2007, the Ruhr-Universität Bochum (RUB) in Germany and Universidad Católica del Norte (UCN) in Chile jointly operate the Universitätssternwarte der Ruhr-Universität Bochum (USB), which is located in direct neighborhood of the future E-ELT of ESO. It is the only observatory powered exclusively by solar panels and wind turbines. Excess power is stored in batteries that allow uninterrupted operation even in windless nights. The scientific equipment consists of three robotic optical telescopes with apertures ranging from 15 cm (RoBoTT) over 25 cm (BESTII) to 40 cm (BMT) and one 80 cm (IRIS) infra-red telescope. The optical telescopes are equipped with Johnson and Sloan broad band filters together with a large number of narrow and intermediate bands. In the infrared, J,H and K filters are available, accompanied by several narrow bands near the K band wavelength. The second Nasmyth focus in the 80 cm telescope feeds a high resolution echelle spectrograph similar to the FEROS instrument of ESO. This variety of instruments has evolved from different collaborations, i.e. with the University of Hawaii (IfA) in the USA, which provided the near-infrared-camera of the IRIS telescope, or with the Deutsches Zentrum für Luft- und Raumfahrt (DLR) in Germany, which provided the BESTII telescope. The highly automatized processes on all telescopes enable a single person to run the whole facility, providing the high cost efficiency required for an university observatory. The excellent site conditions allow projects that require daily observations of astronomical objects over epochs of several months or years. Here we report on such studies of young stellar objects from the Bochum Galactic Disk Survey, the multiplicity of stars, quasar variability or the hunt for exo-planets.

  7. Hormone purification by isoelectric focusing in space

    NASA Technical Reports Server (NTRS)

    Bier, M.

    1988-01-01

    The objective of the program was the definition and development of optimal methods for electrophoretic separations in microgravity. The approach is based on a triad consisting of ground based experiments, mathematical modeling and experiments in microgravity. Zone electrophoresis is a rate process, where separation is achieved in uniform buffers on the basis of differences in electrophoretic mobilities. Optimization and modeling of continuous flow electrophoresis mainly concern the hydrodynamics of the flow process, including gravity dependent fluid convection due to density gradients and gravity independent electroosmosis. Optimization of focusing requires a more complex model describing the molecular transport processes involved in electrophoresis of interacting systems. Three different focusing instruments were designed, embodying novel principles of fluid stabilization. Fluid stability was achieved by: (1) flow streamlining by means of membrane elements in combination with rapid fluid recycling; (2) apparatus rotation in combination with said membrane elements; and (3) shear stress induced by rapid recycling through a narrow gap channel.

  8. Advanced life support control/monitor instrumentation concepts for flight application

    NASA Technical Reports Server (NTRS)

    Heppner, D. B.; Dahlhausen, M. J.; Fell, R. B.

    1986-01-01

    Development of regenerative Environmental Control/Life Support Systems requires instrumentation characteristics which evolve with successive development phases. As the development phase moves toward flight hardware, the system availability becomes an important design aspect which requires high reliability and maintainability. This program was directed toward instrumentation designs which incorporate features compatible with anticipated flight requirements. The first task consisted of the design, fabrication and test of a Performance Diagnostic Unit. In interfacing with a subsystem's instrumentation, the Performance Diagnostic Unit is capable of determining faulty operation and components within a subsystem, perform on-line diagnostics of what maintenance is needed and accept historical status on subsystem performance as such information is retained in the memory of a subsystem's computerized controller. The second focus was development and demonstration of analog signal conditioning concepts which reduce the weight, power, volume, cost and maintenance and improve the reliability of this key assembly of advanced life support instrumentation. The approach was to develop a generic set of signal conditioning elements or cards which can be configured to fit various subsystems. Four generic sensor signal conditioning cards were identified as being required to handle more than 90 percent of the sensors encountered in life support systems. Under company funding, these were detail designed, built and successfully tested.

  9. An overview of instrumentation for the Large Binocular Telescope

    NASA Astrophysics Data System (ADS)

    Wagner, R. Mark

    2012-09-01

    An overview of instrumentation for the Large Binocular Telescope (LBT) is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' x 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the left and right direct F/15 Gregorian foci incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 2000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCI), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at the left and right front bent F/15 Gregorian foci and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multiobject spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 × 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development that can utilize the full 23-m baseline of the LBT include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). LBTI is currently undergoing commissioning on the LBT and utilizing the installed adaptive secondary mirrors in both single- sided and two-sided beam combination modes. In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. Over the past four years the LBC pair, LUCI1, and MODS1 have been commissioned and are now scheduled for routine partner science observations. The delivery of both LUCI2 and MODS2 is anticipated before the end of 2012. The

  10. The Active Role of Instruments in Articulating Knowing and Knowledge: The Case of Animal Qualification Practices in Breeding Organisations

    ERIC Educational Resources Information Center

    Labatut, Julie; Aggeri, Franck; Astruc, Jean-Michel; Bibe, Bernard; Girard, Nathalie

    2009-01-01

    Purpose: The purpose of this paper is to investigate the role of instruments defined as artefacts, rules, models or norms, in the articulation between knowing-in-practice and knowledge, in learning processes. Design/methodology/approach: The paper focuses on a distributed, knowledge-intensive and instrumented activity at the core of any collective…

  11. An Instrument for the Identification of Core Curriculum in the Discipline of Gynaecology

    ERIC Educational Resources Information Center

    Taylor, P. J.

    1976-01-01

    Describes an instrument designed to identify with considerable agreement appropriate knowledge, skills, and attitudes for gynecology curriculum, relate it to other curriculum content, and determine where it should appear in the curriculum. Focus is on clinical problems to be solved and the underlying processes. (JT)

  12. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  13. On the Measurement of Power Law Creep Parameters from Instrumented Indentation

    NASA Astrophysics Data System (ADS)

    Sudharshan Phani, P.; Oliver, W. C.; Pharr, G. M.

    2017-11-01

    Recently the measurement of the creep response of materials at small scales has received renewed interest largely because the equipment required to perform high-temperature nanomechanical testing has become available to an increasing number of researchers. Despite that increased access, there remain several significant experimental and modeling challenges in small-scale mechanical testing at elevated temperatures that are as yet unresolved. In this regard, relating the creep response observed with high-temperature instrumented indentation experiments to macroscopic uniaxial creep response is of great practical value. In this review, we present an overview of various methods currently being used to measure creep with instrumented indentation, with a focus on geometrically self-similar indenters, and their relative merits and demerits from an experimental perspective. A comparison of the various methods to use those instrumented indentation results to predict the uniaxial power law creep response of a wide range of materials will be presented to assess their validity.

  14. 79. SITE INSTRUMENTATION: INTERIOR OF INSTRUMENTATION BUNKER AT 800 WEST, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    79. SITE INSTRUMENTATION: INTERIOR OF INSTRUMENTATION BUNKER AT 800 WEST, WITH WOODEN WORK BENCH - White Sands Missile Range, Trinity Site, Vicinity of Routes 13 & 20, White Sands, Dona Ana County, NM

  15. The Atacama Cosmology Telescope: Instrument

    NASA Astrophysics Data System (ADS)

    Thornton, Robert J.; Atacama Cosmology Telescope Team

    2010-01-01

    The 6-meter Atacama Cosmology Telescope (ACT) is making detailed maps of the Cosmic Microwave Background at Cerro Toco in northern Chile. In this talk, I focus on the design and operation of the telescope and its commissioning instrument, the Millimeter Bolometer Array Camera. The camera contains three independent sets of optics that operate at 148 GHz, 217 GHz, and 277 GHz with arcminute resolution, each of which couples to a 1024-element array of Transition Edge Sensor (TES) bolometers. I will report on the camera performance, including the beam patterns, optical efficiencies, and detector sensitivities. Under development for ACT is a new polarimeter based on feedhorn-coupled TES devices that have improved sensitivity and are planned to operate at 0.1 K.

  16. Urologic laser types and instrumentation.

    PubMed

    Natalin, Ricardo A; Phillips, Courtney K; Clayman, Ralph V; Landman, Jaime

    2008-11-01

    Though the primary role of lasers in urology has always been in the treatment of urolithiasis, there are several other indications for their use. There are many different types of lasers currently available, each with unique properties conducive to treating certain disorders. As such, it is critical that today's urologist understands each laser's characteristics in order to optimize patient selection and treatment. The lasers which are primarily used in urologic applications include the carbon dioxide (CO2) laser; the Neodymium:Yttrium-Aluminum-Garnet (Nd:YAG); the Potassium Titanyl Phosphate (KTP) laser and the Holmium:YAG (Ho:YAG) laser. This review focuses on the unique characteristics of each of these lasers as well as the instrumentation needed utilize and deploy these tools in the urinary tract.

  17. The performance of magnetic lens for focusing VCN-SANS

    NASA Astrophysics Data System (ADS)

    Nop Collaboration; Yamada, M.; Iwashita, Y.; Kanaya, T.; Ichikawa, M.; Tongu, H.; Kennedy, S. J.; Shimizu, H. M.; Mishima, K.; Yamada, N. L.; Hirota, K.; Carpenter, J. M.; Lal, J.; Andersen, K.; Geltenbort, P.; Guerard, B.; Manzin, G.; Hino, M.; Kitaguchi, M.; Bleuel, M.; NOP Collaboration

    2011-04-01

    We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5×104T/m2⩽g‧⩽5.9×104T/m2. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS.We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source (≈3mm) over a wavelength range of 30Å⩽λ⩽48Å in focal length of ≈1.14m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO)100(PPO)65(PEO)100 tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.

  18. Novel approaches to the construction of miniaturized analytical instrumentation

    NASA Technical Reports Server (NTRS)

    Porter, Marc D.; Otoole, Ronald P.; Coldiron, Shelley J.; Deninger, William D.; Deinhammer, Randall S.; Burns, Stanley G.; Bastiaans, Glenn J.; Braymen, Steve D.; Shanks, Howard R.

    1992-01-01

    This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

  19. [Caregiving consequences in mental disorders--definitions and instruments of assessment].

    PubMed

    Ciałkowska-Kuźmińska, Magdalena; Kiejna, Andrzej

    2010-01-01

    Severe mental illnesses have far-reaching consequences for both patients and their relatives. This paper reviews literature on the measures of caregiving consequences. Authors provide a condensed knowledge and research results in the area of caregiving consequences, especially both subjective and objective caregivers' burden. The consequences of care apply to carers' social and leisure activities, financial status, health condition. The burden of care has three fundamental causes: the reorganisation of mental health services, a social isolation of patients and their families and the lack of systemic support for caregivers. The problem of caregiving consequences has been investigated in several studies. In order to identify factors, which have impact on caregiver distress, a variety instruments have been developed. This paper focuses on questionnaires useful for the systematic assessment of both objective and subjective burden: Involvement Evaluation Questionnaire (IEQ), Perceived Family Burden Scale (PFBS), Zarit Caregiver Burden Scale (ZCBS), Experience of Caregiving Inventory (ECI), Family Problems Questionnaire (FPQ). The mentioned instruments proved to be a reliable instrument for measuring caregiver consequences in mental healthcare.

  20. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    PubMed

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  1. Relationship Between Wind Instrument Playing Habits and Symptoms of Temporomandibular Disorders in Non-Professional Musicians.

    PubMed

    Nishiyama, Akira; Tsuchida, Erisa

    2016-01-01

    In this study, we focused on the habits of wind instrumentalists as well as the presence of playing instruments, and investigated associations between the risk of temporomandibular disorders (TMD) and playing wind instruments in non-professional musicians. Seventy-two non-professional players of wind instruments (instrument group) (mean(SD), 20.0(1.1) y; 42 women) and 66 non-players (control group) (22.0(2.6) y; 45 women) participated in this study. Factors were investigated using questionnaires (a screening questionnaire for TMD, instrument playing habits, years of experience, and time played per day). The prevalence of a high risk of TMD was not significantly different between the instrument group (29.2%) and control group (21.2%). In the instrument group, the frequency of subjects who felt mouthpiece pressure in the high risk of TMD group (47.6%) was significantly greater than that in the low risk of TMD group (21.6%). Mouthpiece pressure was found to be a significant factor contributing to a high risk of TMD (odds ratio, 3.31; 95% CI, 1.12-9.79). This study suggests that pressure from the mouthpiece was one of the contributing factors related to a high risk of TMD in non-professional wind instrument players.

  2. Instruments to assess self-care among healthy children: A systematic review of measurement properties.

    PubMed

    Urpí-Fernández, Ana-María; Zabaleta-Del-Olmo, Edurne; Montes-Hidalgo, Javier; Tomás-Sábado, Joaquín; Roldán-Merino, Juan-Francisco; Lluch-Canut, María-Teresa

    2017-12-01

    To identify, critically appraise and summarize the measurement properties of instruments to assess self-care in healthy children. Assessing self-care is a proper consideration for nursing practice and nursing research. No systematic review summarizes instruments of measurement validated in healthy children. Psychometric review in accordance with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. MEDLINE, CINAHL, PsycINFO, Web of Science and Open Grey were searched from their inception to December 2016. Validation studies with a healthy child population were included. Search was not restricted by language. Two reviewers independently assessed the methodological quality of included studies using the COSMIN checklist. Eleven studies were included in the review assessing the measurement properties of ten instruments. There was a maximum of two studies per instrument. None of the studies evaluated the properties of test-retest reliability, measurement error, criterion validity and responsiveness. Internal consistency and structural validity were rated as "excellent" or "good" in four studies. Four studies were rated as "excellent" in content validity. Cross-cultural validity was rated as "poor" in the two studies (three instruments) which cultural adaptation was carried out. The evidence available does not allow firm conclusions about the instruments identified in terms of reliability and validity. Future research should focus on generate evidence about a wider range of measurement properties of these instruments using a rigorous methodology, as well as instrument testing on different countries and child population. © 2017 John Wiley & Sons Ltd.

  3. The LST scientific instruments

    NASA Technical Reports Server (NTRS)

    Levin, G. M.

    1975-01-01

    Seven scientific instruments are presently being studied for use with the Large Space Telescope (LST). These instruments are the F/24 Field Camera, the F/48-F/96 Planetary Camera, the High Resolution Spectrograph, the Faint Object Spectrograph, the Infrared Photometer, and the Astrometer. These instruments are being designed as facility instruments to be replaceable during the life of the Observatory.

  4. Instruments by Telescope | CTIO

    Science.gov Websites

    Visitor's Computer Guidelines Network Connection Request Instruments Instruments by Telescope IR Instruments Single-object IR spectrograph 1.1"x28" ~3500 Hawaii2RG 0.80-2.40 Available SOAR Instruments See gratings 1,800-14,000 with 0.45 arcsec slit Fairchild CCD 4096x4096 0.32-0.98 Available Spartan IR imager

  5. SURVEY INSTRUMENT

    DOEpatents

    Borkowski, C J

    1954-01-19

    This pulse-type survey instrument is suitable for readily detecting {alpha} particles in the presence of high {beta} and {gamma} backgrounds. The instruments may also be used to survey for neutrons, {beta} particles and {gamma} rays by employing suitably designed interchangeable probes and selecting an operating potential to correspond to the particular probe.

  6. An Instrument Development Study for Determining Prospective Science Teachers' Science-Specific Epistemological Beliefs

    ERIC Educational Resources Information Center

    Koksal, Mustafa Serdar; Ertekin, Pelin

    2016-01-01

    The study is focusing on development of an instrument to determine science-specific epistemological beliefs of prospective science teachers. The study involved 364 (male = 82, female = 282) prospective science teachers enrolled in a science teacher education program. The confirmatory factor analysis, reliability analysis and correlation analysis…

  7. Low activated incore instrument

    DOEpatents

    Ekeroth, Douglas E.

    1994-01-01

    Instrumentation for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials.

  8. Trocars: Site Selection, Instrumentation, and Overcoming Complications.

    PubMed

    Gaunay, Geoffrey S; Elsamra, Sammy E; Richstone, Lee

    2016-08-01

    In recent years, laparoscopy and robot-assisted procedures have become more commonplace in urology. Incorporation of these techniques into clinical practice requires extensive knowledge of the surgical approaches and complex instrumentation unique to minimally invasive surgery. In this review, focus will be directed to laparoscopic trocars including differing subtypes, placement in select urologic procedures, and proper use with emphasis on the avoidance of complications. Differing methods for the development of pneumoperitoneum and the associated risks of each will be discussed. The aim of this article is to provide a complete review of laparoscopic trocar use for the practicing urologist.

  9. Early modern mathematical instruments.

    PubMed

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  10. Development of an instrument to analyze organizational characteristics in multidisciplinary care pathways; the case of colorectal cancer.

    PubMed

    Pluimers, Dorine J; van Vliet, Ellen J; Niezink, Anne Gh; van Mourik, Martijn S; Eddes, Eric H; Wouters, Michel W; Tollenaar, Rob A E M; van Harten, Wim H

    2015-04-09

    To analyze the organization of multidisciplinary care pathways such as colorectal cancer care, an instrument was developed based on a recently published framework that was earlier used in analyzing (monodisciplinary) specialist cataract care from a lean perspective. The instrument was constructed using semi-structured interviews and direct observation of the colorectal care process based on a Rapid Plant Assessment. Six lean aspects that were earlier established that highly impact process design, were investigated: operational focus, autonomous work cell, physical lay-out of resources, multi-skilled team, pull planning and non-value adding activities. To test reliability, clarity and face validity of the instrument, a pilot study was performed in eight Dutch hospitals. In the pilot it proved feasible to apply the instrument and generate the intended information. The instrument consisted of 83 quantitative and 24 qualitative items. Examples of results show differences in operational focus, number of patient visits needed for diagnosis, numbers of staff involved with treatment, the implementation of protocols and utilization of one-stop-shops. Identification of waste and non-value adding activities may need further attention. Based on feedback from involved clinicians the face validity was acceptable and the results provided useful feedback- and benchmark data. The instrument proved to be reliable and valid for broader implementation in Dutch health care. The limited number of cases made statistical analysis not possible and further validation studies may shed better light on variation. This paper demonstrates the use of an instrument to analyze organizational characteristics in colorectal cancer care from a lean perspective. Wider use might help to identify best organizational practices for colorectal surgery. In larger series the instrument might be used for in-depth research into the relation between organization and patient outcomes. Although we found no reason

  11. DAN instrument for NASA`s MSL mission: fast science data processing and instrument commanding for Mars surface operations and for field tests

    NASA Astrophysics Data System (ADS)

    Vostrukhin, A.; Kozyrev, A.; Litvak, M.; Malakhov, A.; Mitrofanov, I.; Mokrousov, M.; Sanin, A.; Tretyakov, V.

    2009-04-01

    The Dynamic Albedo of Neutrons (DAN) instrument is contributed by Russian Space Agency to NASA for Mars Science Laboratory mission which was originally scheduled for 2009 and now is shifted to 2011. The design of DAN instrument is partially inherited from HEND instrument for NASA's Mars Odyssey, which now successfully operates providing global mapping of martian neutron albedo, searching the distribution of martian water and observing the martian seasonal cycles. DAN is specially designed as an active neutron instrument for surface operations onboard mobile platforms. It is able to focus science investigations on local surface area around rover with horizontal resolution about 1 meter and vertical penetration about 0.5 m. The primary goal of DAN is the exploration of the hydrogen content of the bulk Martian subsurface material. This data will be used to estimate the content of chemically bound water in the hydrated minerals. The concept of DAN operations is based on combination of neutron activation analysis and neutron well logging tequnique, which are commonly used in the Earth geological applications. DAN consists blocks of Detectors and Electronics (DE) and Pulse Neutron Generator (PNG). The last one is used to irradiate the martian subsurface by pulses of 14MeV neutrons with changeable frequency up to 10 Hz. The first one detects post-pulse afterglow of neutrons, as they were thermalized down to epithermal and thermal energies within the martian subsurface. The result of detections are so called die away curves of neutrons afterglow, which show flux and time profile of thermalized neutrons and bring to us the observational signature of layering structure of martian regolith in part of depth distribution of Hydrogen (most effective element for thermalization of neutrons). In this study we focus on the development, verification and validation of DAN fast data processing and commanding. It is necessary to perform deconvolution from counting statistic in DAN

  12. Characterization of the Effect of Wing Surface Instrumentation on UAV Airfoil Performance

    NASA Technical Reports Server (NTRS)

    Ratnayake, Nalin A.

    2009-01-01

    Recently proposed flight research at NASA Dryden Flight Research Center (DFRC) has prompted study into the aerodynamic effects of modifications made to the surfaces of laminar airfoils. The research is focused on the high-aspect ratio, laminar-flow type wings commonly found on UAVs and other aircraft with a high endurance requirement. A broad range of instrumentation possibilities, such as structural, pressure, and temperature sensing devices may require the alteration of the airfoil outer mold line as part of the installation process. This study attempts to characterize the effect of installing this additiona1 instrumentation on key airfoil performance factors, such as transition location, lift and drag curves, and stall point. In particular, the general case of an airfoil that is channeled in the spanwise direction is considered, and the impact on key performance characteristics is assessed. Particular attention is focused on exploring the limits of channel depth and low-Reynolds number on performance and stall characteristics. To quantify the effect of increased skin friction due to premature transition caused by protruding or recessed instrumentation, two simplified, conservative scenarios are used to consider two potential sources of diaturbance: A) that leading edge alterations would cause linearly expanding areas (triangles) of turbulent flow on both surfaces of the wing upstream of the natural transition point, and B) that a channel or bump on the upper surface would trip turbulent flow across the whole upper surface upstream of the natural transition point. A potentially more important consideration than the skin friction drag increment is the change in overall airfoil performance due to the installation of instrumentation along most of the wingspan. To quantify this effect, 2D CFD simulations of the flow over a representative mid-span airfoil section were conducted in order to assess the change in lift and drag curves for the airfoil in the presence of

  13. EASY-An Instrument for Surveillance of Physical Activity in Youth.

    PubMed

    Pate, Russell R; McIver, Kerry; Dowda, Marsha; Schenkelberg, Michaela A; Beets, Michael; DiStefano, Christine

    2018-01-23

    Physical activity (PA) promotion among youth is a public health priority and there is a need for robust surveillance systems to help support such initiatives. Existing youth PA self-report instruments that are used for surveillance lack information regarding the types and contexts of activity. Further, these instruments have limited validity with accelerometry. The purpose of the present study was to develop a self-report instrument, with sound psychometric properties, for monitoring compliance with PA guidelines in youth. In focus groups, 162 middle school students identified 30 forms of PA that are highly prevalent in that age group. We incorporated these activities into three preliminary forms of a self-report instrument. An independent sample of middle school students (n = 537) was randomly assigned to complete one of the three preliminary versions of the instrument. Rasch analysis was applied to the responses to the three formats, and a yes/no plus frequency format emerged as the preferred method. A third sample of 342 middle school students then completed the yes/no plus frequency instrument twice following a seven-day period during which they wore an accelerometer. Using both Rasch analysis and traditional correlational methods, validity and reliability of a 14-item instrument were established. Data were collected during 2012 - 2015. Spearman correlation coefficient for the association between the cumulative score for the 14 items and minutes per day of accelerometry-derived moderate-to-vigorous physical activity (MVPA) was 0.33 (95% CI 0.22, 0.43; p<.001). Sensitivity and specificity of the 14-item instrument was 0.90 and 0.44, respectively. The study produced a PA self-report instrument for youth that was found to be reliable (r=0.91), valid versus accelerometry (r=0.33), and acceptably specific and sensitive in detecting compliance with PA guidelines.This is an open-access article distributed under the terms of the Creative Commons Attribution

  14. Low activated incore instrument

    DOEpatents

    Ekeroth, D.E.

    1994-04-19

    Instrumentation is described for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials. 9 figures.

  15. Evaluating musical instruments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, D. Murray

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.

  16. Important variables for parents' postnatal sense of security: evaluating a new Swedish instrument (the PPSS instrument).

    PubMed

    Persson, Eva K; Dykes, Anna-Karin

    2009-08-01

    to evaluate dimensions of both parents' postnatal sense of security the first week after childbirth, and to determine associations between the PPSS instrument and different sociodemographic and situational background variables. evaluative, cross-sectional design. 113 mothers and 99 fathers with children live born at term, from five hospitals in southern Sweden. mothers and fathers had similar feelings concerning postnatal sense of security. Of the dimensions in the PPSS instrument, a sense of midwives'/nurses' empowering behaviour, a sense of one's own general well-being and a sense of the mother's well-being as experienced by the father were the most important dimensions for parents' experienced security. A sense of affinity within the family (for both parents) and a sense of manageable breast feeding (for mothers) were not significantly associated with their experienced security. A sense of participation during pregnancy and general anxiety were significantly associated background variables for postnatal sense of security for both parents. For the mothers, parity and a sense that the father was participating during pregnancy were also significantly associated. more focus on parents' participation during pregnancy as well as midwives'/nurses' empowering behaviour during the postnatal period will be beneficial for both parents' postnatal sense of security.

  17. BIRA-IASB Mars activities and instrument capabilities

    NASA Astrophysics Data System (ADS)

    Drummond, R.; Vandaele, A.-C.; Gillotay, D.; Willame, Y.; Depiesse, C.; Patel, M.; Daerden, F.; Neefs, E.; Ristic, B.; Montmessin, F.

    2009-04-01

    The Belgian Institute of Space Aeronomy (BIRA-IASB) is involved in many areas of Mars exploration, and has been for a long time. Current activities include analysis of SPICAM data, 3D atmospheric modelling as well as instrument development and characterization. This paper will focus on two different instruments to study the Martian atmosphere. UVIS(Patel, 2006) is part of the Exomars payload, that will gather information on the UV levels on the ground, study climatology and sterilisation and also be able to detect organic material in sublimating permafrost. BIRA-IASB is carrying out the characterization and calibration of UVIS. SOIR is an infra-red spectrometer that uses solar occultation measurements to examine major and minor constituents of planetary atmospheres. SOIR is currently orbiting Venus on the VEX spacecraft and has already made several interesting discoveries including the first observations of a new band of a CO2 isotopologue. The data from SOIR-VEX has allowed us to study the instrumental characteristics and perform a sensitivity study(Mahieux, 2008). These properties have been used to simulate realistic SOIR measurements of Mars atmospheric spectra. This work is supported by extensive 3D chemistry modeling work, as described in a paper by Frank Daerden (PS2.9Atmospheres of terrestrial planets). M. R. Patel, et al.,(2006) The UV-VIS spectrometer for the ExoMars mission, in 36th COSPAR Scientific Assembly, Beijing, China. A. Mahieux, et al.,(2008), Appl. Opt. 47 (13), 2252-65.

  18. Scoping Study Investigating PWR Instrumentation during a Severe Accident Scenario

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rempe, J. L.; Knudson, D. L.; Lutz, R. J.

    The accidents at the Three Mile Island Unit 2 (TMI-2) and Fukushima Daiichi Units 1, 2, and 3 nuclear power plants demonstrate the critical importance of accurate, relevant, and timely information on the status of reactor systems during a severe accident. These events also highlight the critical importance of understanding and focusing on the key elements of system status information in an environment where operators may be overwhelmed with superfluous and sometimes conflicting data. While progress in these areas has been made since TMI-2, the events at Fukushima suggests that there may still be a potential need to ensure thatmore » critical plant information is available to plant operators. Recognizing the significant technical and economic challenges associated with plant modifications, it is important to focus on instrumentation that can address these information critical needs. As part of a program initiated by the Department of Energy, Office of Nuclear Energy (DOE-NE), a scoping effort was initiated to assess critical information needs identified for severe accident management and mitigation in commercial Light Water Reactors (LWRs), to quantify the environment instruments monitoring this data would have to survive, and to identify gaps where predicted environments exceed instrumentation qualification envelop (QE) limits. Results from the Pressurized Water Reactor (PWR) scoping evaluations are documented in this report. The PWR evaluations were limited in this scoping evaluation to quantifying the environmental conditions for an unmitigated Short-Term Station BlackOut (STSBO) sequence in one unit at the Surry nuclear power station. Results were obtained using the MELCOR models developed for the US Nuclear Regulatory Commission (NRC)-sponsored State of the Art Consequence Assessment (SOARCA) program project. Results from this scoping evaluation indicate that some instrumentation identified to provide critical information would be exposed to conditions that

  19. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel – design concept and experimental demonstration

    DOE PAGES

    Henzlova, Daniela; Menlove, Howard Olsen; Rael, Carlos D.; ...

    2015-10-09

    Our paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. We describe the initial feasibility demonstration of the CIPN instrument, which involved measurements of fourmore » pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. Lastly, these features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.« less

  20. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel – design concept and experimental demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henzlova, Daniela; Menlove, Howard Olsen; Rael, Carlos D.

    Our paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. We describe the initial feasibility demonstration of the CIPN instrument, which involved measurements of fourmore » pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. Lastly, these features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.« less

  1. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Wilcox, J. Z.; Urgiles, E.; Toda, R.; George, T.; Crisp, J.

    2005-01-01

    Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the

  2. A comprehensive review of sensors and instrumentation methods in devices for musical expression.

    PubMed

    Medeiros, Carolina Brum; Wanderley, Marcelo M

    2014-07-25

    Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009-2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.

  3. A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression

    PubMed Central

    Medeiros, Carolina Brum; Wanderley, Marcelo M.

    2014-01-01

    Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009–2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments. PMID:25068865

  4. Woodwind Instrument Maintenance.

    ERIC Educational Resources Information Center

    Sperl, Gary

    1980-01-01

    The author presents a simple maintenance program for woodwind instruments which includes the care of tendon corks, the need for oiling keys, and methods of preventing cracks in woodwind instruments. (KC)

  5. Magnetic compound refractive lens for focusing and polarizing cold neutron beams.

    PubMed

    Littrell, K C; te Velthuis, S G E; Felcher, G P; Park, S; Kirby, B J; Fitzsimmons, M R

    2007-03-01

    Biconcave cylindrical lenses are used to focus beams of x rays or neutrons using the refractive properties of matter. In the case of neutrons, the refractive properties of magnetic induction can similarly focus and simultaneously polarize the neutron beam without the concomitant attenuation of matter. This concept of a magnetic refractive lens was tested using a compound lens consisting of 99 pairs of cylindrical permanent magnets. The assembly successfully focused the intensity of a white beam of cold neutrons of one spin state at the detector, while defocusing the other. This experiment confirmed that a lens of this nature may boost the intensity locally by almost an order of magnitude and create a polarized beam. An estimate of the performance of a more practically dimensioned device suitable for incorporation in reflectometers and slit-geometry small angle scattering instruments is given.

  6. Learning Incubator: an instrument to foster entrepreneurship in Nursing.

    PubMed

    Backes, Dirce Stein; Obem, Marielle Kulakowski; Pereira, Simone Barbosa; Gomes, Carine Alves; Backes, Marli Terezinha Stein; Erdmann, Alacoque Lorenzini

    2015-01-01

    this study aimed to know the contributions of the Learning Incubator to the process of lifelong education in health. this is a qualitative field research whose data was collected from August to December 2014 by the focus group technique. The research had 34 employees of a Teaching Hospital in the central region of the state of Rio Grande do Sul that participated previously in the incubation process. from the data encoded by content analysis, three themes were selected: Learning Incubator - welcoming and integrating space; An instigating instrument that enhances possibilities; Continuous and lifelong education strategy. the Learning Incubator is an important instrument to foster entrepreneurship in nursing and other health areas due to its capacity of rethinking mechanized practices, to the possibility of instigating new ways of being and acting, and to the ability of creating and developing new ideas based on individual and institutional needs.

  7. Development and evaluation of an instrument to measure parental satisfaction with quality of care in neonatal follow-up.

    PubMed

    Butt, Michelle L; Pinelli, Janet; Boyle, Michael H; Thomas, Helen; Hunsberger, Mabel; Saigal, Saroj; Lee, David S; Fanning, Jamie K; Austin, Patricia

    2009-02-01

    The goal of this study was to develop and subsequently evaluate the psychometric properties of a new discriminative instrument to measure parental satisfaction with the quality of care provided in neonatal follow-up (NFU) programs. The methodological framework for developing and evaluating measurement scales described by Streiner and Norman (Health Measurement Scales: A Practical Guide to Their Development and Use. 3rd ed. New York: Oxford University Press; 2003) was used for the study. Informing the phases of the research was a sample of 24 health care professionals and 381 parents who use NFU services. A comprehensive list of items representing the construct, parental satisfaction with quality of care, was generated from published reliable and valid instruments, research studies, focus groups with health care experts, and focus groups with parents. Using a clinimetric approach, the 62 items generated were reduced to 39 items based on parents' ratings of importance and refinement of the items by the research team. After content validation and pretesting, the instrument was tested with parents and underwent item-analysis. The resulting 16-item instrument was composed of 2 subscales, Process and Outcomes. Evaluation of the instrument's psychometric properties indicated adequate test-retest reliability (intraclass correlation coefficient = 0.72) and internal consistency (Process subscale, alpha = 0.77; Outcomes subscale, alpha = 0.90; overall instrument, alpha = 0.90), as well as good content and construct validity. A confirmatory factor analysis supported the multidimensionality of the construct. This new instrument provides clinicians and policy-makers with a tool to assess parental satisfaction with the quality of care in NFU, so areas of dissatisfaction can be identified and changes implemented to optimize service provision.

  8. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine.

    PubMed

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-05-01

    To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure ( p =0.049 and 0.050, respectively). When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion.

  9. Instrument Modeling and Synthesis

    NASA Astrophysics Data System (ADS)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  10. A Multirater Instrument for the Assessment of Simulated Pediatric Crises

    PubMed Central

    Calhoun, Aaron W; Boone, Megan; Miller, Karen H; Taulbee, Rebecca L; Montgomery, Vicki L; Boland, Kimberly

    2011-01-01

    first step toward instrument validation. Gap analysis reveals disparities between faculty and self-assessments that indicate inadequate participant self-reflection. Identifying self-overappraisal can facilitate focused interventions. PMID:22379528

  11. The TMT instrumentation program

    NASA Astrophysics Data System (ADS)

    Simard, Luc; Crampton, David; Ellerbroek, Brent; Boyer, Corinne

    2010-07-01

    An overview of the current status of the Thirty Meter Telescope (TMT) instrumentation program is presented. Conceptual designs for the three first light instruments (IRIS, WFOS and IRMS) are in progress, as well as feasibility studies of MIRES. Considerable effort is underway to understand the end-to-end performance of the complete telescopeadaptive optics-instrument system under realistic conditions on Mauna Kea. Highly efficient operation is being designed into the TMT system, based on a detailed investigation of the observation workflow to ensure very fast target acquisition and set up of all subsystems. Future TMT instruments will almost certainly involve contributions from institutions in many different locations in North America and partner nations. Coordinating and optimizing the design and construction of the instruments to ensure delivery of the best possible scientific capabilities is an interesting challenge. TMT welcomes involvement from all interested instrument teams.

  12. [Design and validation of an instrument to assess families at risk for health problems].

    PubMed

    Puschel, Klaus; Repetto, Paula; Solar, María Olga; Soto, Gabriela; González, Karla

    2012-04-01

    There is a paucity of screening instruments with a high clinical predictive value to identify families at risk and therefore, develop focused interventions in primary care. To develop an easy to apply screening instrument with a high clinical predictive value to identify families with a higher health vulnerability. In the first stage of the study an instrument with a high content validity was designed through a review of existent instruments, qualitative interviews with families and expert opinions following a Delphi approach of three rounds. In the second stage, concurrent validity was tested through a comparative analysis between the pilot instrument and a family clinical interview conducted to 300 families randomly selected from a population registered at a primary care clinic in Santiago. The sampling was blocked based on the presence of diabetes, depression, child asthma, behavioral disorders, presence of an older person or the lack of previous conditions among family members. The third stage, was directed to test the clinical predictive validity of the instrument by comparing the baseline vulnerability obtained by the instrument and the change in clinical status and health related quality of life perceptions of the family members after nine months of follow-up. The final SALUFAM instrument included 13 items and had a high internal consistency (Cronbach's alpha: 0.821), high test re-test reproducibility (Pearson correlation: 0.84) and a high clinical predictive value for clinical deterioration (Odds ratio: 1.826; 95% confidence intervals: 1.101-3.029). SALUFAM instrument is applicable, replicable, has a high content validity, concurrent validity and clinical predictive value.

  13. Use of 3 mm percutaneous instruments with 5 mm end effectors during different laparoscopic procedures.

    PubMed

    David, Giulia; Boni, Luigi; Rausei, Stefano; Cassinotti, Elisa; Dionigi, Gianlorenzo; Rovera, Francesca; Spampatti, Sebastiano; Colombo, Elisabetta Marta; Dionigi, Renzo

    2013-01-01

    With a recent focus on minimizing the visibility of scars, new techniques have been developed. Minilaparoscopy reemerged as an attractive option for surgery as it limits tissue trauma, reduces post-operative pain and improves cosmesis. This study was designed to describe our experience with percutaneous trocarless 3 mm instruments used in combination with standard 5 mm and 10 mm laparoscopic instruments in different general surgery procedures. We used the PSS (Percutaneous Surgical Set, Ethicon Endo surgery, Cincinnati, OH, USA) in different surgical procedures as accessory instruments in combination with standard 5 mm and 10 mm standard laparoscopic instruments. The use of percutaneous instruments was safe and feasible in all performed procedures. The surgical technique was not modified. The percutaneous instruments can assure a good grip and can be used for traction and counter-traction. No complications have been described. No pain at the site of insertion has been reported. The skin, muscle and peritoneal defects were smaller than with the 3 mm laparoscopic traditional instruments. Percutaneous approach seems to be a good option in general surgery in terms of efficiency, offering better cosmetic results and good pain control. Copyright © 2013 Elsevier Ltd and Surgical Associates Ltd. All rights reserved.

  14. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    NASA Technical Reports Server (NTRS)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  15. Attention to gender in communication skills assessment instruments in medical education: a review.

    PubMed

    Dielissen, Patrick; Bottema, Ben; Verdonk, Petra; Lagro-Janssen, Toine

    2011-03-01

    Gender is increasingly regarded as an important factor in doctor-patient communication education. This review aims to assess if and how gender is addressed by current assessment instruments for communication skills in medical education. In 2009 at Radboud University Nijmegen Medical Centre, an online search was conducted in the bibliographic databases PubMed, PsycINFO and ERIC for references about communication skills assessment instruments designed to be completed by trained faculty staff and used in medical education. The search strategy used the following search terms: 'consultation skills'; 'doctor-patient communication'; 'physician-patient relations'; 'medical education'; 'instruments'; 'measurement', and 'assessment'. Papers published between January 1999 and June 2009 were included. The assessment instruments identified were analysed for gender-specific content. The search yielded 21 communication skills assessment instruments. Only two of the 17 checklists obtained explicitly considered gender as a communication-related issue. Only six of 21 manuals considered gender in any way and none gave specific details to explain which aspects of communication behaviour should be assessed with regard to gender. Very few communication assessment instruments in medical education focus on gender. Nevertheless, interest exists in using gender in communication skills assessment. The criteria for and purpose of assessing gender in communication skills in medical education are yet to be clarified. © Blackwell Publishing Ltd 2011.

  16. Active Neutron and Gamma-Ray Instrumentation for In Situ Planetary Science Applications

    NASA Technical Reports Server (NTRS)

    Parsons, A.; Bodnarik, J.; Evans, L.; Floyd, A.; Lim, L.; McClanahan, T.; Namkung, M.; Nowicki, S.; Schweitzer, J.; Starr, R.; hide

    2011-01-01

    We describe the development of an instrument capable of detailed in situ bulk geochemical analysis of the surface of planets, moons, asteroids, and comets. This instrument technology uses a pulsed neutron generator to excite the solid materials of a planet and measures the resulting neutron and gamma-ray emission with its detector system. These time-resolved neutron and gamma-ray data provide detailed information about the bulk elemental composition, chemical context, and density distribution of the soil within 50 cm of the surface. While active neutron scattering and neutron-induced gamma-ray techniques have been used extensively for terrestrial nuclear well logging applications, our goal is to apply these techniques to surface instruments for use on any solid solar system body. As described, experiments at NASA Goddard Space Flight Center use a prototype neutron-induced gamma-ray instrument and the resulting data presented show the promise of this technique for becoming a versatile, robust, workhorse technology for planetary science, and exploration of any of the solid bodies in the solar system. The detection of neutrons at the surface also provides useful information about the material. This paper focuses on the data provided by the gamma-ray detector.

  17. The 1997 HST Calibration Workshop with a New Generation of Instruments

    NASA Technical Reports Server (NTRS)

    Casertano, S. (Editor); Jedrzejewski, R. (Editor); Keyes, T. (Editor); Stevens, M. (Editor)

    1997-01-01

    The Second Servicing mission in early 1997 has brought major changes to the Hubble Space Telescope (HST). Two of the original instruments, Faint Object Spectrograph (FOS) and Goddard High Resolution Spectrograph (GHRS), were taken out, and replaced by completely new instruments, the Space Telescope Imaging Spectrograph (STIS) and the Near Infrared Camera Multi-Object Spectrograph (NICMOS). Two new types of detectors were installed, and for the first time, HST gained infrared capabilities. A new Fine Guidance Sensor (FGS) was installed, with an alignment mechanism that could improve substantially both guiding and astrometric capabilities. With all these changes come new challenges. The characterization of the new instruments has required a major effort, both by their respective Investigation Definition Teams and at the Space Telescope Science Institute. All necessary final calibrations for the retired spectrographs needed to be carried out, and their properties definitively characterized. At the same time, work has continued to improve our understanding of the instruments that have remained on board. The results of these activities were discussed in the 1997 HST (Hubble Space Telescope) Calibration Workshop. The main focus of the Workshop was to provide users with the tools and the understanding they need to use HST's instruments and archival data to the best of their possibilities. This book contains the written record of the Workshop. As such, it should provide a valuable tool to all interested in using existing HST data or in proposing for new observations.

  18. The quantitative measurement of organizational culture in health care: a review of the available instruments.

    PubMed

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-06-01

    To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase "organizational culture." In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources.

  19. First Results on Interstellar Magnetic Fields from the HAWC+ Instrument for SOFIA

    NASA Astrophysics Data System (ADS)

    Dowell, C. Darren; HAWC+ Instrument Team; HAWC+ Science Team

    2018-06-01

    HAWC+, a second-generation SOFIA instrument designed to map far-infrared intensity and polarization, was commissioned in late 2016 and made first science observations in SOFIA Cycles 4 and 5. We describe basic characteristics of the instrument, report on the commissioning flights and data analysis pipeline, and show some example science products resulting from Guaranteed-Time Observations (GTO). HAWC+ and SOFIA provide unique access to the far-infrared (50 - 250 micron) spectral range for polarimetry. Far-IR polarization arises from dust grains aligned with respect to the magnetic field, as well as synchrotron radiation, and the GTO program focuses primarily on the magnetic field structure of nearby molecular clouds and the Galactic center, and the physical characteristics of dust.

  20. Next Generation Polar Seismic Instrumentation Challenges

    NASA Astrophysics Data System (ADS)

    Parker, T.; Beaudoin, B. C.; Gridley, J.; Anderson, K. R.

    2011-12-01

    Polar region logistics are the limiting factor for deploying deep field seismic arrays. The IRIS PASSCAL Instrument Center, in collaboration with UNAVCO, designed and deployed several systems that address some of the logistical constraints of polar deployments. However, continued logistics' pressures coupled with increasingly ambitious science projects require further reducing the logistics required for deploying both summer and over winter stations. Our focus is to reduce station power requirements and bulk, thereby minimizing the time and effort required to deploy these arrays. We will reduce the weight of the battery bank by incorporating the most applicable new high energy-density battery technology. Using these batteries will require a completely new power management system along with an appropriate smart enclosure. The other aspect will be to integrate the digitizing system with the sensor. Both of these technologies should reduce the install time and shipping volume plus weight while reducing some instrument costs. We will also continue work on an effective Iridium telemetry solution for automated data return. The costs and limitations of polar deep-field science easily justifies a specialized development effort but pays off doubly in that we will continue to leverage the advancements in reduced logistics and increased performance for the benefit of low-latitude seismic research.

  1. CAE "FOCUS" for modelling and simulating electron optics systems: development and application

    NASA Astrophysics Data System (ADS)

    Trubitsyn, Andrey; Grachev, Evgeny; Gurov, Victor; Bochkov, Ilya; Bochkov, Victor

    2017-02-01

    Electron optics is a theoretical base of scientific instrument engineering. Mathematical simulation of occurring processes is a base for contemporary design of complicated devices of the electron optics. Problems of the numerical mathematical simulation are effectively solved by CAE system means. CAE "FOCUS" developed by the authors includes fast and accurate methods: boundary element method (BEM) for the electric field calculation, Runge-Kutta- Fieghlberg method for the charged particle trajectory computation controlling an accuracy of calculations, original methods for search of terms for the angular and time-of-flight focusing. CAE "FOCUS" is organized as a collection of modules each of which solves an independent (sub) task. A range of physical and analytical devices, in particular a microfocus X-ray tube of high power, has been developed using this soft.

  2. Planck focal plane instruments: advanced modelization and combined analysis

    NASA Astrophysics Data System (ADS)

    Zonca, Andrea; Mennella, Aniello

    2012-08-01

    This thesis is the result of my work as research fellow at IASF-MI, Milan section of the Istituto di Astrofisica Spaziale e Fisica Cosmica, part of INAF, Istituto Nazionale di Astrofisica. This work started in January 2006 in the context of the PhD school program in Astrophysics held at the Physics Department of Universita' degli Studi di Milano under the supervision of Aniello Mennella. The main topic of my work is the software modelling of the Low Frequency Instrument (LFI) radiometers. The LFI is one of the two instruments on-board the European Space Agency Planck Mission for high precision measurements of the anisotropies of the Cosmic Microwave Background (CMB). I was also selected to participate at the International Doctorate in Antiparticles Physics, IDAPP. IDAPP is funded by the Italian Ministry of University and Research (MIUR) and coordinated by Giovanni Fiorentini (Universita' di Ferrara) with the objective of supporting the growing collaboration between the Astrophysics and Particles Physics communities. It is an international program in collaboration with the Paris PhD school, involving Paris VI, VII and XI Universities, leading to a double French-Italian doctoral degree title. My work was performed with the co-tutoring of Jean-Michel Lamarre, Instrument Scientist of the High Frequency Instrument (HFI), the bolometric instrument on-board Planck. Thanks to this collaboration I had the opportunity to work with the HFI team for four months at the Paris Observatory, so that the focus of my activity was broadened and included the study of cross-correlation between HFI and LFI data. Planck is the first CMB mission to have on-board the same satellite very different detection technologies, which is a key element for controlling systematic effects and improve measurements quality.

  3. Mars 2020 Entry, Descent and Landing Instrumentation (MEDLI2)

    NASA Technical Reports Server (NTRS)

    Bose, Deepak; Wright, Henry; White, Todd; Schoenenberger, Mark; Santos, Jose; Karlgaard, Chris; Kuhl, Chris; Oishi, TOmo; Trombetta, Dominic

    2016-01-01

    This paper will introduce Mars Entry Descent and Landing Instrumentation (MEDLI2) on NASA's Mars2020 mission. Mars2020 is a flagship NASA mission with science and technology objectives to help answer questions about possibility of life on Mars as well as to demonstrate technologies for future human expedition. Mars2020 is scheduled for launch in 2020. MEDLI2 is a suite of instruments embedded in the heatshield and backshell thermal protection systems of Mars2020 entry vehicle. The objectives of MEDLI2 are to gather critical aerodynamics, aerothermodynamics and TPS performance data during EDL phase of the mission. MEDLI2 builds up the success of MEDLI flight instrumentation on Mars Science Laboratory mission in 2012. MEDLI instrumentation suite measured surface pressure and TPS temperature on the heatshield during MSL entry into Mars. MEDLI data has since been used for unprecedented reconstruction of aerodynamic drag, vehicle attitude, in-situ atmospheric density, aerothermal heating, transition to turbulence, in-depth TPS performance and TPS ablation. [1,2] In addition to validating predictive models, MEDLI data has highlighted extra margin available in the MSL forebody TPS, which can potentially be used to reduce vehicle parasitic mass. MEDLI2 expands the scope of instrumentation by focusing on quantities of interest not addressed in MEDLI suite. The type the sensors are expanded and their layout on the TPS modified to meet these new objectives. The paper will provide key motivation and governing requirements that drive the choice and the implementation of the new sensor suite. The implementation considerations of sensor selection, qualification, and demonstration of minimal risk to the host mission will be described. The additional challenges associated with mechanical accommodation, electrical impact, data storage and retrieval for MEDLI2 system, which extends sensors to backshell will also be described.

  4. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine

    PubMed Central

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-01-01

    Objective To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. Methods We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. Results There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure (p=0.049 and 0.050, respectively). Conclusion When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion. PMID:29631384

  5. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    ERIC Educational Resources Information Center

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  6. Aeronautic Instruments. Section II : Altitude Instruments

    NASA Technical Reports Server (NTRS)

    Mears, A H; Henrickson, H B; Brombacher, W G

    1923-01-01

    This report is Section two of a series of reports on aeronautic instruments (Technical Report nos. 125 to 132, inclusive). This section discusses briefly barometric altitude determinations, and describes in detail the principal types of altimeters and barographs used in aeronautics during the recent war. This is followed by a discussion of performance requirements for such instruments and an account of the methods of testing developed by the Bureau of Standards. The report concludes with a brief account of the results of recent investigations. For accurate measurements of altitude, reference must also be made to thermometer readings of atmospheric temperature, since the altitude is not fixed by atmospheric pressure alone. This matter is discussed in connection with barometric altitude determination.

  7. Astronomical Instrumentation System Markup Language

    NASA Astrophysics Data System (ADS)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  8. The FASES instrument development and experiment preparation for the ISS

    NASA Astrophysics Data System (ADS)

    Picker, Gerold; Gollinger, Klaus; Greger, Ralf; Dettmann, Jan; Winter, Josef; Dewandre, Thierry; Castiglione, Luigi; Vincent-Bonnieu, Sebastien; Liggieri, Libero; Clausse, Daniele; Antoni, Mickael

    The FASES experiments target the investigation of the stability of emulsions. The main objec-tives are the study of the surfactant adsorption at the liquid / liquid interfaces, the interaction of the droplets as well as the behaviour of the liquid film between nearby drops. Particular focus is given to the dynamic droplet evolution during emulsion destabilisation. The results of the experiments shall support development of methods for the modelling of droplet size distri-butions, which are important to many industries using stable emulsions like food production, cosmetics and pharmaceutics or unstable emulsions as required for applications in waste water treatment or crude oil recovery. The development of the experimental instrumentation was initiated in 2002. The flight instru-ment hardware development was started in 2004 and finally the flight unit was completed in 2009. Currently the final flight preparation is proceeding targeting a launch to the International Space Station (ISS) with Progress 39P in September 2010. The experiment setup of the instrument is accommodated in a box type insert called Experiment Container (EC), which will be installed in the Fluid Science Laboratory part of the European Columbus module of the ISS. The EC is composed of two diagnostics instruments for the investigation of transparent and opaque liquid emulsion. The transparent emulsions will be subject to the experiment called "Investigations on drop/drop interactions in Transparent Emulsions" (ITEM). The opaque emulsion samples will be studied in the experiment called "Investigations on concentrated or opaque Emulsions and on Phase Inversions" (EMPI). The thermal conditioning unit (TCU) allows performing homogeneous thermalization, tem-perature sweeps, emulsion preparation by stirrer, and optical diagnostics with a scanning mi-croscope. The objective of the instrument is the 3D reconstruction of the emulsion droplet distribution in the liquid matrix in terms of the droplet sizes

  9. "Every boy & girl a scientist": instruments for children in interwar Britain.

    PubMed

    Keene, Melanie

    2007-06-01

    Historians of science have identified toys as part of their subject's material culture, but there has been little exploration of the production and use of educational or playful objects. Moreover, academic writing on science for children has focused on the eighteenth and nineteenth centuries. This essay argues that our understanding of historical science education can be enhanced by exploring twentieth-century instruments. It uses the example of Construments sets, with which children could build a wide variety of optical instruments from a series of standardized parts. Invented by C. W. Hansel, a school science master, Construments were founded in and responded to contemporary educational practices and debates over "general science," as well as addressing characteristic interwar concerns about adaptability and economy and older ideals of rational entertainment. By exploring the company's instruments, promotional literature, and magazine, and by drawing on the memories of contemporary users, I reconstruct the contexts in which Construments were used, emphasizing the creation of heterogeneous communities vital for the transmission of skills and knowledge.

  10. Jefferson Teamwork Observation Guide (JTOG): An Instrument to Observe Teamwork Behaviors.

    PubMed

    Lyons, Kevin J; Giordano, Carolyn; Speakman, Elizabeth; Smith, Kellie; Horowitz, June A

    2016-01-01

    Interprofessional education (IPE) is becoming an integral part of the education of health professions students. However, teaching students to become successful members of interprofessional teams is complex, and it is important for students to learn the combinations of skills necessary for teams to function effectively. There are many instruments available to measure many features related to IPE. However, these instruments are often too cumbersome to use in an observational situation since they tend to be lengthy and contain many abstract characteristics that are difficult to identify. The Jefferson Teamwork Observation Guide (JTOG) is a short tool that was created for students early in their educational program to observe teams in action with a set of guidelines to help them focus their observation on behaviors indicative of good teamwork. The JTOG was developed over a 2-year period based on student and clinician feedback and the input of experts in IPE. While initially developed as a purely educational tool for prelicensure students, it is becoming clear that it is an easy-to-use instrument that assesses the behavior of clinicians in practice.

  11. Validation of Existing Diagnosis of Autism in Mainland China Using Standardised Diagnostic Instruments

    ERIC Educational Resources Information Center

    Sun, Xiang; Allison, Carrie; Auyeung, Bonnie; Zhang, Zhixiang; Matthews, Fiona E.; Baron-Cohen, Simon; Brayne, Carol

    2015-01-01

    Research to date in mainland China has mainly focused on children with autistic disorder rather than Autism Spectrum Conditions and the diagnosis largely depended on clinical judgment without the use of diagnostic instruments. Whether children who have been diagnosed in China before meet the diagnostic criteria of Autism Spectrum Conditions is not…

  12. A multimodal instrument for real-time in situ study of ultrasound and cavitation mediated drug delivery.

    PubMed

    Bian, Shuning; Seth, Anjali; Daly, Dan; Carlisle, Robert; Stride, Eleanor

    2017-03-01

    The development of a multimodal instrument capable of real-time in situ measurements of cavitation activity and effect in tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments is described here. The instrument features an acoustic arm that can expose phantoms to high-intensity focused-ultrasound while measuring cavitation activity and an optical arm that monitors cavitation effect using confocal microscopy. This combination of modalities allows real-time in situ characterisation of drug delivery in tissue and tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments. A representative result, obtained with a tissue mimicking phantom and acoustically activated droplets, is presented here as a demonstration of the instrument's capabilities and potential applications.

  13. Development of the Multi-Angle Stratospheric Aerosol Radiometer (MASTAR) Instrument

    NASA Astrophysics Data System (ADS)

    DeLand, M. T.; Colarco, P. R.; Kowalewski, M. G.; Gorkavyi, N.; Ramos-Izquierdo, L.

    2017-12-01

    Aerosol particles in the stratosphere ( 15-25 km altitude), both produced naturally and perturbed by volcanic eruptions and anthropogenic emissions, continue to be a source of significant uncertainty in the Earth's energy budget. Stratospheric aerosols can offset some of the warming effects caused by greenhouse gases. These aerosols are currently monitored using measurements from the Ozone Mapping and Profiling Suite (OMPS) Limb Profiler (LP) instrument on the Suomi NPP satellite. In order to improve the sensitivity and spatial coverage of these aerosol data, we are developing an aerosol-focused compact version of the OMPS LP sensor called Multi-Angle Stratospheric Aerosol Radiometer (MASTAR) to fly on a 3U Cubesat satellite, using a NASA Instrument Incubator Program (IIP) grant. This instrument will make limb viewing measurements of the atmosphere in multiple directions simultaneously, and uses only a few selected wavelengths to reduce size and cost. An initial prototype version has been constructed using NASA GSFC internal funding and tested in the laboratory. Current design work is targeted towards a preliminary field test in Spring 2018. We will discuss the scientific benefits of MASTAR and the status of the project.

  14. Virtual Instrument Simulator for CERES

    NASA Technical Reports Server (NTRS)

    Chapman, John J.

    1997-01-01

    A benchtop virtual instrument simulator for CERES (Clouds and the Earth's Radiant Energy System) has been built at NASA, Langley Research Center in Hampton, VA. The CERES instruments will fly on several earth orbiting platforms notably NASDA's Tropical Rainfall Measurement Mission (TRMM) and NASA's Earth Observing System (EOS) satellites. CERES measures top of the atmosphere radiative fluxes using microprocessor controlled scanning radiometers. The CERES Virtual Instrument Simulator consists of electronic circuitry identical to the flight unit's twin microprocessors and telemetry interface to the supporting spacecraft electronics and two personal computers (PC) connected to the I/O ports that control azimuth and elevation gimbals. Software consists of the unmodified TRW developed Flight Code and Ground Support Software which serves as the instrument monitor and NASA/TRW developed engineering models of the scanners. The CERES Instrument Simulator will serve as a testbed for testing of custom instrument commands intended to solve in-flight anomalies of the instruments which could arise during the CERES mission. One of the supporting computers supports the telemetry display which monitors the simulator microprocessors during the development and testing of custom instrument commands. The CERES engineering development software models have been modified to provide a virtual instrument running on a second supporting computer linked in real time to the instrument flight microprocessor control ports. The CERES Instrument Simulator will be used to verify memory uploads by the CERES Flight Operations TEAM at NASA. Plots of the virtual scanner models match the actual instrument scan plots. A high speed logic analyzer has been used to track the performance of the flight microprocessor. The concept of using an identical but non-flight qualified microprocessor and electronics ensemble linked to a virtual instrument with identical system software affords a relatively inexpensive

  15. AIR Instrument Array

    NASA Technical Reports Server (NTRS)

    Jones, I. W.; Wilson, J. W.; Maiden, D. L.; Goldhagen, P.; Shinn, J. L.

    2003-01-01

    The large number of radiation types composing the atmospheric radiation requires a complicated combination of instrument types to fully characterize the environment. A completely satisfactory combination has not as yet been flown and would require a large capital outlay to develop. In that the funds of the current project were limited to essential integration costs, an international collaboration was formed with partners from six countries and fourteen different institutions with their own financial support for their participation. Instruments were chosen to cover sensitivity to all radiation types with enough differential sensitivity to separate individual components. Some instruments were chosen as important to specify the physical field component and other instruments were chosen on the basis that they could be useful in dosimetric evaluation. In the present paper we will discuss the final experimental flight package for the ER-2 flight campaign.

  16. Preliminary analysis of a flexible instrument mount for large instruments on the Space Shuttle

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A flexible instrument mount for large instruments on the space shuttle is analyzed. Concepts for pointing instruments while in orbit, with weights up to 2000 Kg and dimensions of 2 to 3 m were identified and analyzed. A mechanical concept was selected that can accommodate a set class of scientific instruments such as the LAMAR X-ray experiment with 24 LAMAR telescopes.

  17. Using confidence intervals to evaluate the focus alignment of spectrograph detector arrays.

    PubMed

    Sawyer, Travis W; Hawkins, Kyle S; Damento, Michael

    2017-06-20

    High-resolution spectrographs extract detailed spectral information of a sample and are frequently used in astronomy, laser-induced breakdown spectroscopy, and Raman spectroscopy. These instruments employ dispersive elements such as prisms and diffraction gratings to spatially separate different wavelengths of light, which are then detected by a charge-coupled device (CCD) or complementary metal-oxide-semiconductor (CMOS) detector array. Precise alignment along the optical axis (focus position) of the detector array is critical to maximize the instrumental resolution; however, traditional approaches of scanning the detector through focus lack a quantitative measure of precision, limiting the repeatability and relying on one's experience. Here we propose a method to evaluate the focus alignment of spectrograph detector arrays by establishing confidence intervals to measure the alignment precision. We show that propagation of uncertainty can be used to estimate the variance in an alignment, thus providing a quantitative and repeatable means to evaluate the precision and confidence of an alignment. We test the approach by aligning the detector array of a prototype miniature echelle spectrograph. The results indicate that the procedure effectively quantifies alignment precision, enabling one to objectively determine when an alignment has reached an acceptable level. This quantitative approach also provides a foundation for further optimization, including automated alignment. Furthermore, the procedure introduced here can be extended to other alignment techniques that rely on numerically fitting data to a model, providing a general framework for evaluating the precision of alignment methods.

  18. Aircraft Speed Instruments

    NASA Technical Reports Server (NTRS)

    Beij, K Hilding

    1933-01-01

    This report presents a concise survey of the measurement of air speed and ground speed on board aircraft. Special attention is paid to the pitot-static air-speed meter which is the standard in the United States for airplanes. Air-speed meters of the rotating vane type are also discussed in considerable detail on account of their value as flight test instruments and as service instruments for airships. Methods of ground-speed measurement are treated briefly, with reference to the more important instruments. A bibliography on air-speed measurement concludes the report.

  19. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    NASA Astrophysics Data System (ADS)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  20. AXAF SIM focus mechanism study

    NASA Technical Reports Server (NTRS)

    Tananbaum, H. D.; Whitbeck, E.

    1994-01-01

    The design requirements and initial design concept for the AXAF-I Science Instrument Module (SIM) were reviewed at Ball on September 29, 1993. The concept design SIM focus mechanism utilizes a planetary gearset, with redundant motors, to drive a large ring (called 'main housing bearing') via a spur gearset. This large drive ring actuates three tangent bar links (called 'push rods'), which in turn actuate three levers (called 'pin levers'). Each of the three pin levers rotates an 'eccentric pin,' which in turn moves the base of a bipod flexure in both the radial (normal to optical axis) and axial (focus along optical axis) directions. Three bipod flexures are employed, equally spaced at 120 degrees apart, the base of each being translated in the two directions as described above. A focus adjustment is made by rotating the drive ring, which drives the push rods and therefore the pin levers, which in turn rotate the eccentric pins, finally imparting the two motions to the base of each of the bipod flexures. The axial translation (focus adjustment) of the focused structure is the sum of the direct axial motion plus axial motion which comes from uniformly squeezing the three bipod bases radially inward. SAO documented the following concerns regarding the focus mechanism in memo WAP-FY94-001, dated October 7, 1993: (1) The focus adjustment depends, in large part, on the structural properties (stiffnesses and end fixities) of the bipod flexures, push rods, pin levers and eccentric pins. If these properties are not matched very well, then lateral translations as well as unwanted rotations of the focussed structure will accompany focus motion. In addition, the stackup of linkage tolerances and any nonuniform wear in the linkages will result in the same unwanted motions. Thermal gradients will also affect these motions. At the review Ball did not present supporting analyses to support their choice of this design concept. (2) The proposed 'primary' method of measuring focus

  1. Focused Ion Beam Recovery and Analysis of Interplanetary Dust Particles (IDPs) and Stardust Analogues

    NASA Technical Reports Server (NTRS)

    Graham, G. A.; Bradley, J. P.; Bernas, M.; Stroud, R. M.; Dai, Z. R.; Floss, C.; Stadermann, F. J.; Snead, C. J.; Westphal, A. J.

    2004-01-01

    Meteoritics research is a major beneficiary of recent developments in analytical instrumentation [1,2]. Integrated studies in which multiple analytical techniques are applied to the same specimen are providing new insight about the nature of IDPs [1]. Such studies are dependent on the ability to prepare specimens that can be analyzed in multiple instruments. Focused ion beam (FIB) microscopy has revolutionized specimen preparation in materials science [3]. Although FIB has successfully been used for a few IDP and meteorite studies [1,4-6], it has yet to be widely utilized in meteoritics. We are using FIB for integrated TEM/NanoSIMS/synchrotron infrared (IR) studies [1].

  2. Formation and psychometric evaluation of a health-related quality of life instrument for children living with HIV in India.

    PubMed

    Das, Aritra; Detels, Roger; Afifi, Abdelmonem A; Javanbakht, Marjan; Sorvillo, Frank; Panda, Samiran

    2018-03-01

    In-depth interviews and focus group discussions were conducted to inform the development of an instrument to measure the health-related quality of life of children living with HIV. The QOL-CHAI instrument consists of four generic core scales of the "Pediatric Quality of Life Inventory" and two HIV-targeted scales-"symptoms" and "discrimination." A piloting exercise involving groups of children living with HIV and HIV-negative children born to HIV-infected parents provided evidence for the acceptable psychometric properties and usability of the instrument. It is expected that the QOL-CHAI can serve well as a brief, standardized, and culturally appropriate instrument for assessing health-related quality of life of Indian children living with HIV.

  3. "Fly-by-Wireless" : A Revolution in Aerospace Architectures for Instrumentation and Control

    NASA Technical Reports Server (NTRS)

    Studor, George F.

    2007-01-01

    The conference presentation provides background information on Fly-by-Wireless technologies as well as reasons for implementation, CANEUS project goals, cost of change for instrumentation, reliability, focus areas, conceptual Hybrid SHMS architecture for future space habitats, real world problems that the technology can solve, evolution of Micro-WIS systems, and a WLEIDS system overview and end-to-end system design.

  4. [Deformation evaluation of ProTaper nickel-titanium rotary instruments in curved canals instrumentation in vitro].

    PubMed

    Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei

    2008-04-01

    To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.

  5. Psychometric Properties of the German Version of the Health Regulatory Focus Scale

    PubMed Central

    Schmalbach, Bjarne; Spina, Roy; Steffens-Guerra, Ileana; Franke, Gabriele H.; Kliem, Sören; Michaelides, Michalis P.; Hinz, Andreas; Zenger, Markus

    2017-01-01

    The Health Regulatory Focus Scale (HRFS) is a short scale which measures an individual's prevention and promotion focus in a health-specific context. The main objective of this study was to examine the psychometric properties of the newly translated German version of the HRFS. Reliability and item characteristics were found to be satisfactory. Validity of both subscales toward other psychological constructs including behavioral approach and avoidance, core self-evaluations, optimism, pessimism, neuroticism, as well as several measures of physical and mental health was shown. In addition, invariance of the measure across age and gender groups was shown. Exploratory as well as confirmatory factor analyses clearly indicated a two-factorial structure with a moderate correlation between the two latent constructs. Differences in health promotion and prevention focus between socio-demographic groups are discussed. The HRFS is found to be a valid and reliable instrument for the assessment of regulatory focus in health-related environments. PMID:29184528

  6. The Development of Intercultural Competence in Saudi Academic Migrants: A Collective Instrumental Case Study

    ERIC Educational Resources Information Center

    Hagar, Trenton James

    2016-01-01

    In this collective instrumental case study, the focus was on understanding the issue of Intercultural Competence within Saudi academic migrants. The purpose of this study was to determine how Saudi academic migrants gain intercultural competence through the development of attitudes, knowledge, and skills, as defined by Deardorff's (2006) process…

  7. The Business of Experimental Physics: Instrument Makers and Itinerant Lecturers in the German Enlightenment

    ERIC Educational Resources Information Center

    Hochadel, Oliver

    2007-01-01

    While it is a commonplace in the historiography of electricity that itinerant lecturers and instrument makers were "somehow" part of the "electrical flare" of the 18th century, very little is actually known about them, about their background, their careers and their self-understanding. Yet, research focusing on these…

  8. A review of instrumentation kinematics of engine-driven nickel-titanium instruments.

    PubMed

    Çapar, I D; Arslan, H

    2016-02-01

    Over the years, NiTi alloys have become indispensable materials in endodontic treatment. With technological advancements in metallurgy, manufacturers have attempted to produce instruments with enhanced features. In parallel with these developments, endodontic motors have undergone improvements in terms of torque control and kinematics that are adjustable in different directions. This review presents an overview of the advancements in instrumentation kinematics and the effect of instrumentation kinematics on root canal shaping procedures and instrument performance. The literature search for this narrative review was conducted in Google Scholar, Scopus, PubMed and Web of Science using the keywords 'kinematics and endodontics' and 'reciprocation and endodontics'. In addition, historical literature was searched using the keyword 'nickel-titanium and endodontics'. Overall, 143 articles were included up to 2015. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. A systematic review of instruments to assess organizational readiness for knowledge translation in health care.

    PubMed

    Gagnon, Marie-Pierre; Attieh, Randa; Ghandour, El Kebir; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A; Grimshaw, Jeremy

    2014-01-01

    The translation of research into practices has been incomplete. Organizational readiness for change (ORC) is a potential facilitator of effective knowledge translation (KT). However we know little about the best way to assess ORC. Therefore, we sought to systematically review ORC measurement instruments. We searched for published studies in bibliographic databases (Pubmed, Embase, CINAHL, PsychINFO, Web of Science, etc.) up to November 1st, 2012. We included publications that developed ORC measures and/or empirically assessed ORC using an instrument at the organizational level in the health care context. We excluded articles if they did not refer specifically to ORC, did not concern the health care domain or were limited to individual-level change readiness. We focused on identifying the psychometric properties of instruments that were developed to assess readiness in an organization prior to implementing KT interventions in health care. We used the Standards for Educational and Psychological Testing to assess the psychometric properties of identified ORC measurement instruments. We found 26 eligible instruments described in 39 publications. According to the Standards for Educational and Psychological Testing, 18 (69%) of a total of 26 measurement instruments presented both validity and reliability criteria. The Texas Christian University -ORC (TCU-ORC) scale reported the highest instrument validity with a score of 4 out of 4. Only one instrument, namely the Modified Texas Christian University - Director version (TCU-ORC-D), reported a reliability score of 2 out of 3. No information was provided regarding the reliability and validity of five (19%) instruments. Our findings indicate that there are few valid and reliable ORC measurement instruments that could be applied to KT in the health care sector. The TCU-ORC instrument presents the best evidence in terms of validity testing. Future studies using this instrument could provide more knowledge on its relevance to

  10. Towards an Operational Definition of Effective Co-Teaching: Instrument Development, Validity, and Reliability

    ERIC Educational Resources Information Center

    La Monte, Michelle Evonne

    2012-01-01

    This study focused on developing a valid and reliable instrument that can not only identify successful co-teaching, but also the professional development needs of co-teachers and their administrators in public schools. Two general questions about the quality of co-teaching were addressed in this study: (a) How well did descriptors within each of…

  11. Ball-and-Socket Mount for Instruments

    NASA Technical Reports Server (NTRS)

    Kaelber, E.

    1986-01-01

    Jaws engage instrument precisely but release it readily. Mounting mechanism holds scientific instrument securely, allows instrument to be oriented, and minimizes conduction of heat to and from instrument. Mechanism also allows quick replacement of instrument.

  12. Costa Rican environmental service payments: The use of a financial instrument in participatory forest management.

    PubMed

    Miranda, Miriam; Dieperink, Carel; Glasbergen, Pieter

    2006-10-01

    The core element of the Costa Rican forestry policy is a financial instrument called the environmental service payment. This instrument rewards forest owners for the environmental services (the mitigation of greenhouse gases, the protection of watersheds and scenic beauty, and the development of biodiversity) their forests provide. In this article, the experiences with this new instrument are analyzed by focusing on the way interests are represented and access is granted, the openness of information exchange, whether social learning occurred, and whether decision-making authority is shared. The analysis is based on a survey conducted in the Huetar Norte Region and on in-depth interviews with the major stakeholders. The Costa Rican case indicates that financial instruments can be used to share responsibilities and that stakeholders can successfully cooperate on forest issues. It also shows that such a participatory approach is only promising if certain cultural, economic, organizational, and political conditions are met.

  13. Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty.

    PubMed

    Chan, W Cw; Pinder, E; Loeffler, M

    2016-08-01

    To compare patient-specific instrumentation (PSI) with conventional instrumentation in total knee arthroplasty (TKA) in terms of component alignment, operating time, and the learning curve required in a non-teaching hospital. Records of 33 men and 29 women aged 50 to 88 (mean, 71) years who underwent TKA for osteoarthritis using PSI (n=31) or conventional instrumentation (n=31) by a single surgeon were reviewed. The choice of instrumentation was made by the patient; the surgeon did not express any preference and had not used PSI before. All patients used the same cemented, cruciate-retaining system. The PSI and conventional instrumentation groups were comparable in terms of age, body mass index (BMI), American Society of Anesthesiologists grade, pre- and post-operative haemoglobin level, and the need for blood transfusion. Compared with conventional instrumentation, PSI resulted in a smaller coronal femoral component angle (7.7º vs. 6.4º, p=0.003) and posterior tibial slope angle (6.4º vs. 3.2º, p=0.0001), and smaller variance of the respective angles (p=0.006 and p=0.003). In patients with a BMI ≥30, PSI still resulted in a smaller posterior tibial slope angle (5.8º vs. 3.1º, p=0.015) and variance of the angle (p=0.02). The mean tourniquet time was shorter in the PSI group in all patients (p=0.013) and in patients with BMI ≥30 kg/m2 (p=0.0008), and its variance was also smaller in the PSI group (p=0.0004). There was no learning curve required. PSI was simple to use, with no learning curve required. It can be used in non-teaching hospitals and in patients with a high BMI and in cases where the use of an intramedullary alignment guide would be problematic due to previous femoral trauma.

  14. Protocol for the design of an instrument to measure preadolescent children's self-report of covert aggression and bullying

    PubMed Central

    Nelson, Helen Jean; Kendall, Garth Edward; Burns, Sharyn; Schonert-Reichl, Kimberly

    2015-01-01

    Introduction Covert bullying in schools is associated with a range of academic, social, emotional and physical health problems. Much research has focused on bullying, but there remains a gap in understanding about covert aggression and how to most accurately and reliably measure children's own reports of this behaviour. This paper reviews relevant literature and outlines a research project that aims to develop a self-report instrument that effectively measures covert aggression and bullying. It is anticipated that this research will result in a standardised instrument that is suitable for exploring preadolescent children's experiences of covert aggressive behaviour. The data collected by the instrument will enhance health and education professionals understanding of covert bullying behaviours and will inform the design and evaluation of interventions. Methods and analysis Relational developmental systems theory will guide the design of an online self-report instrument. The first phase of the project will include a critical review of the research literature, focus groups with children aged 8–12 years (grades 4–6) in Perth, Western Australia, and expert review. The instrument will be explored for content and face validity prior to the assessment of convergent and discriminant validity, internal consistency and test-retest reliability. Ethics and dissemination The study has been approved by the Curtin University of Human Research Ethics Committee (RDHS-38-15) and by the Executive Principal of the participating school. PMID:26553834

  15. Satellite oceanography - The instruments

    NASA Technical Reports Server (NTRS)

    Stewart, R. H.

    1981-01-01

    It is pointed out that no instrument is sensitive to only one oceanographic variable; rather, each responds to a combination of atmospheric and oceanic phenomena. This complicates data interpretation and usually requires that a number of observations, each sensitive to somewhat different phenomena, be combined to provide unambiguous information. The distinction between active and passive instruments is described. A block diagram illustrating the steps necessary to convert data from satellite instruments into oceanographic information is included, as is a diagram illustrating the operation of a radio-frequency radiometer. Attention is also given to the satellites that carry the various oceanographic instruments.

  16. [Controlling instruments in radiology].

    PubMed

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  17. BICEP2 III: Instrumental systematics

    DOE PAGES

    Ade, P. A. R.

    2015-11-23

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call "deprojection," for filtering the leading ordermore » beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ~10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. Lastly, the contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10 –3.« less

  18. BICEP2 III: Instrumental systematics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ade, P. A. R.

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call "deprojection," for filtering the leading ordermore » beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ~10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. Lastly, the contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10 –3.« less

  19. FOXSI-2: Upgrades of the Focusing Optics X-ray Solar Imager for its Second Flight

    NASA Astrophysics Data System (ADS)

    Christe, Steven; Glesener, Lindsay; Buitrago-Casas, Camilo; Ishikawa, Shin-Nosuke; Ramsey, Brian; Gubarev, Mikhail; Kilaru, Kiranmayee; Kolodziejczak, Jeffery J.; Watanabe, Shin; Takahashi, Tadayuki; Tajima, Hiroyasu; Turin, Paul; Shourt, Van; Foster, Natalie; Krucker, Sam

    2016-03-01

    The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload flew for the second time on 2014 December 11. To enable direct Hard X-Ray (HXR) imaging spectroscopy, FOXSI makes use of grazing-incidence replicated focusing optics combined with fine-pitch solid-state detectors. FOXSI’s first flight provided the first HXR focused images of the Sun. For FOXSI’s second flight several updates were made to the instrument including updating the optics and detectors as well as adding a new Solar Aspect and Alignment System (SAAS). This paper provides an overview of these updates as well as a discussion of their measured performance.

  20. Instrumentation at Paranal Observatory: maintaining the instrument suite of five large telescopes and its interferometer alive

    NASA Astrophysics Data System (ADS)

    Gillet, Gordon; Alvarez, José Luis; Beltrán, Juan; Bourget, Pierre; Castillo, Roberto; Diaz, Álvaro; Haddad, Nicolás; Leiva, Alfredo; Mardones, Pedro; O'Neal, Jared; Ribes, Mauricio; Riquelme, Miguel; Robert, Pascal; Rojas, Chester; Valenzuela, Javier

    2010-07-01

    This presentation provides interesting miscellaneous information regarding the instrumentation activities at Paranal Observatory. It introduces the suite of 23 instruments and auxiliary systems that are under the responsibility of the Paranal Instrumentation group, information on the type of instruments, their usage and downtime statistics. The data is based on comprehensive data recorded in the Paranal Night Log System and the Paranal Problem Reporting System whose principles are explained as well. The work organization of the 15 team members around the high number of instruments is laid out, which includes: - Maintaining older instruments with obsolete components - Receiving new instruments and supporting their integration and commissioning - Contributing to future instruments in their developing phase. The assignments of the Instrumentation staff to the actual instruments as well as auxiliary equipment (Laser Guide Star Facility, Mask Manufacturing Unit, Cloud Observation Tool) are explained with respect to responsibility and scheduling issues. The essential activities regarding hardware & software are presented, as well as the technical and organizational developments within the group towards its present and future challenges.

  1. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    ERIC Educational Resources Information Center

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  2. Instrument-mounted displays for reducing cognitive load during surgical navigation.

    PubMed

    Herrlich, Marc; Tavakol, Parnian; Black, David; Wenig, Dirk; Rieder, Christian; Malaka, Rainer; Kikinis, Ron

    2017-09-01

    Surgical navigation systems rely on a monitor placed in the operating room to relay information. Optimal monitor placement can be challenging in crowded rooms, and it is often not possible to place the monitor directly beside the situs. The operator must split attention between the navigation system and the situs. We present an approach for needle-based interventions to provide navigational feedback directly on the instrument and close to the situs by mounting a small display onto the needle. By mounting a small and lightweight smartwatch display directly onto the instrument, we are able to provide navigational guidance close to the situs and directly in the operator's field of view, thereby reducing the need to switch the focus of view between the situs and the navigation system. We devise a specific variant of the established crosshair metaphor suitable for the very limited screen space. We conduct an empirical user study comparing our approach to using a monitor and a combination of both. Results from the empirical user study show significant benefits for cognitive load, user preference, and general usability for the instrument-mounted display, while achieving the same level of performance in terms of time and accuracy compared to using a monitor. We successfully demonstrate the feasibility of our approach and potential benefits. With ongoing technological advancements, instrument-mounted displays might complement standard monitor setups for surgical navigation in order to lower cognitive demands and for improved usability of such systems.

  3. The Quantitative Measurement of Organizational Culture in Health Care: A Review of the Available Instruments

    PubMed Central

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-01-01

    Objective To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. Data Sources A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase “organizational culture.” In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. Data Extraction For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Principal Findings Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. Conclusions A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources. PMID:12822919

  4. Prognostic Factors for Recovery After Anterior Debridement/Bone Grafting and Posterior Instrumentation for Lumbar Spinal Tuberculosis.

    PubMed

    Yao, Yuan; Zhang, Huiyu; Liu, Huan; Zhang, Zhengfeng; Tang, Yu; Zhou, Yue

    2017-08-01

    Anterior debridement/bone grafting/posterior instrumentation is a common selection for the treatment of lumbar spinal tuberculosis (LST). To date, no study has focused on the prognostic factors for recovery after this surgery. We included 144 patients who experienced anterior debridement/bone grafting/posterior instrumentation for LST. The recovery rate based on the Japanese Orthopedic Association (JOA) score was used to assess recovery. The Kaplan-Meier method and Cox regression analysis were used to identify the prognostic factors for recovery postoperatively. For the prognostic factors worth further consideration, the changes in JOA scores within the 24-month follow-up period were identified by repeated-measures analysis of variance. Paralysis/nonparalysis, duration of symptoms (≥3/<3 months), number of involved vertebrae (>2/≤2), and posterior open/percutaneous instrumentation were identified as prognostic factors for recovery postoperatively. The prognostic factor of open/percutaneous instrumentation was then further compared for potential clinical application. Patients in the percutaneous instrumentation group achieved higher JOA scores than those in the open instrumentation group in the early stages postoperatively (1-3 months), but this effect equalized at 6 months postoperatively. Patients in the open instrumentation group experienced longer operation time and less cost than those in the percutaneous instrumentation group. Nonparalysis, shorter symptom duration, fewer involved vertebrae, and posterior percutaneous instrumentation (compared with open instrumentation) are considered favorable prognostic factors. Patients in the percutaneous instrumentation group achieved higher JOA scores than those in the open instrumentation group in the early stages postoperatively (1-3 months), but no significant difference was observed in long-term JOA scores (6-24 months). Copyright © 2017. Published by Elsevier Inc.

  5. Towards automatic musical instrument timbre recognition

    NASA Astrophysics Data System (ADS)

    Park, Tae Hong

    This dissertation is comprised of two parts---focus on issues concerning research and development of an artificial system for automatic musical instrument timbre recognition and musical compositions. The technical part of the essay includes a detailed record of developed and implemented algorithms for feature extraction and pattern recognition. A review of existing literature introducing historical aspects surrounding timbre research, problems associated with a number of timbre definitions, and highlights of selected research activities that have had significant impact in this field are also included. The developed timbre recognition system follows a bottom-up, data-driven model that includes a pre-processing module, feature extraction module, and a RBF/EBF (Radial/Elliptical Basis Function) neural network-based pattern recognition module. 829 monophonic samples from 12 instruments have been chosen from the Peter Siedlaczek library (Best Service) and other samples from the Internet and personal collections. Significant emphasis has been put on feature extraction development and testing to achieve robust and consistent feature vectors that are eventually passed to the neural network module. In order to avoid a garbage-in-garbage-out (GIGO) trap and improve generality, extra care was taken in designing and testing the developed algorithms using various dynamics, different playing techniques, and a variety of pitches for each instrument with inclusion of attack and steady-state portions of a signal. Most of the research and development was conducted in Matlab. The compositional part of the essay includes brief introductions to "A d'Ess Are ," "Aboji," "48 13 N, 16 20 O," and "pH-SQ." A general outline pertaining to the ideas and concepts behind the architectural designs of the pieces including formal structures, time structures, orchestration methods, and pitch structures are also presented.

  6. Research Methods, Statistical Procedures, and Psychometric Integrity of Instruments Used in Doctor of Education Dissertations at the University of Alabama 1984-1988.

    ERIC Educational Resources Information Center

    Jarrell, Michele E.; And Others

    Procedures used in Doctor of Education (Ed.D.) dissertations at the University of Alabama (Tuscaloosa) were studied. Focus was on identifying: (1) characteristics of the research designs used; (2) sources of the instruments used to collect data; (3) reports of reliability estimates and evidence of validity of the instruments; and (4) types of…

  7. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    NASA Astrophysics Data System (ADS)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  8. Chromatin Remodeling Function of BRCA1 and its Implication in Regulation of DNA Replication

    DTIC Science & Technology

    2000-09-01

    1F., Cayanan, C., Barilla , D., and Monteiro, A. N. (2000) Cancer Res 60(9), 2411-8 Shore, D. (1994) Trends Genet 10(11), 408-12 32. Li, B...D., and Nasmyth, K. (1987) Cell 51, 721-32 34. Morse, R. H. (2000) Trends Genet 16, 51-3 13 35. Hayes, F., Cayanan, C., Barilla , D., and Monteiro, A

  9. Space applications instrumentation systems

    NASA Technical Reports Server (NTRS)

    Minzner, R. A.; Oberholtzer, J. D.

    1972-01-01

    A compendium of resumes of 158 instrument systems or experiments, of particular interest to space applications, is presented. Each resume exists in a standardized format, permitting entries for 26 administrative items and 39 scientific or engineering items. The resumes are organized into forty groups determined by the forty spacecraft with which the instruments are associated. The resumes are followed by six different cross indexes, each organized alphabetically according to one of the following catagories: instrument name, acronym, name of principal investigator, name of organization employing the principal investigator, assigned experiment number, and spacecraft name. The resumes are associated with a computerized instrument resume search and retrieval system.

  10. The South African Astronomical Observatory instrumentation software architecture and the SHOC instruments

    NASA Astrophysics Data System (ADS)

    van Gend, Carel; Lombaard, Briehan; Sickafoose, Amanda; Whittal, Hamish

    2016-07-01

    Until recently, software for instruments on the smaller telescopes at the South African Astronomical Observatory (SAAO) has not been designed for remote accessibility and frequently has not been developed using modern software best-practice. We describe a software architecture we have implemented for use with new and upgraded instruments at the SAAO. The architecture was designed to allow for multiple components and to be fast, reliable, remotely- operable, support different user interfaces, employ as much non-proprietary software as possible, and to take future-proofing into consideration. Individual component drivers exist as standalone processes, communicating over a network. A controller layer coordinates the various components, and allows a variety of user interfaces to be used. The Sutherland High-speed Optical Cameras (SHOC) instruments incorporate an Andor electron-multiplying CCD camera, a GPS unit for accurate timing and a pair of filter wheels. We have applied the new architecture to the SHOC instruments, with the camera driver developed using Andor's software development kit. We have used this to develop an innovative web-based user-interface to the instrument.

  11. The roles of lesson study in the development of mathematics learning instrument based on learning trajectory

    NASA Astrophysics Data System (ADS)

    Misnasanti; Dien, C. A.; Azizah, F.

    2018-03-01

    This study is aimed to describe Lesson Study (LS) activity and its roles in the development of mathematics learning instruments based on Learning Trajectory (LT). This study is a narrative study of teacher’s experiences in joining LS activity. Data collecting in this study will use three methods such as observation, documentations, and deep interview. The collected data will be analyzed with Milles and Huberman’s model that consists of reduction, display, and verification. The study result shows that through LS activity, teachers know more about how students think. Teachers also can revise their mathematics learning instrument in the form of lesson plan. It means that LS activity is important to make a better learning instruments and focus on how student learn not on how teacher teach.

  12. Robot-like dexterity without computers and motors: a review of hand-held laparoscopic instruments with wrist-like tip articulation

    PubMed Central

    Anderson, Patrick L.; Lathrop, Ray A.; Webster, Robert J.

    2018-01-01

    Introduction Conventional manual laparoscopic instruments for minimally invasive surgery have limited dexterity within the patient, making procedures challenging. Surgical robotic systems offer enhanced articulation, but at substantial financial costs. This has motivated the development of high-dexterity, low-cost laparoscopic instruments. Areas covered This article reviews both commercial and academic results on creating fully mechanical (i.e. non-robotic) laparoscopic instruments that provide wrists or wrist-like dexterity within the patient. We review the state of the art in the development of these mechanical instruments, focusing on the surgeon interface, wrist mechanism, and the kinematic mapping between the two. Expert commentary Current articulated mechanical laparoscopic instruments exhibit a wide range of designs, with no clear consensus on what makes such devices easy to use. As these technologies mature, user studies are needed to determine surgeon preferences. Articulated, low-cost instruments have the potential to impact the minimally invasive surgery market if they provide compelling benefits to surgeons. PMID:26808896

  13. Robot-like dexterity without computers and motors: a review of hand-held laparoscopic instruments with wrist-like tip articulation.

    PubMed

    Anderson, Patrick L; Lathrop, Ray A; Webster, Robert J

    2016-07-01

    Conventional manual laparoscopic instruments for minimally invasive surgery have limited dexterity within the patient, making procedures challenging. Surgical robotic systems offer enhanced articulation, but at substantial financial costs. This has motivated the development of high-dexterity, low-cost laparoscopic instruments. This article reviews both commercial and academic results on creating fully mechanical (i.e. non-robotic) laparoscopic instruments that provide wrists or wrist-like dexterity within the patient. We review the state of the art in the development of these mechanical instruments, focusing on the surgeon interface, wrist mechanism, and the kinematic mapping between the two. Expert commentary: Current articulated mechanical laparoscopic instruments exhibit a wide range of designs, with no clear consensus on what makes such devices easy to use. As these technologies mature, user studies are needed to determine surgeon preferences. Articulated, low-cost instruments have the potential to impact the minimally invasive surgery market if they provide compelling benefits to surgeons.

  14. Relapse processes after the extinction of instrumental learning: Renewal, resurgence, and reacquisition

    PubMed Central

    Bouton, Mark E.; Winterbauer, Neil E.; Todd, Travis P.

    2012-01-01

    It is widely recognized that extinction (the procedure in which a Pavlovian conditioned stimulus or an instrumental action is repeatedly presented without its reinforcer) weakens behavior without erasing the original learning. Most of the experiments that support this claim have focused on several “relapse” effects that occur after Pavlovian extinction, which collectively suggest that the original learning is saved through extinction. However, although such effects do occur after instrumental extinction, they have not been explored there in as much detail. This article reviews recent research in our laboratory that has investigated three relapse effects that occur after the extinction of instrumental (operant) learning. In renewal, responding returns after extinction when the behavior is tested in a different context; in resurgence, responding recovers when a second response that has been reinforced during extinction of the first is itself put on extinction; and in rapid reacquisition, extinguished responding returns rapidly when the response is reinforced again. The results provide new insights into extinction and relapse, and are consistent with principles that have been developed to explain extinction and relapse as they occur after Pavlovian conditioning. Extinction of instrumental learning, like Pavlovian learning, involves new learning that is relatively dependent on the context for expression. PMID:22450305

  15. Instrumentation issues in implementation science.

    PubMed

    Martinez, Ruben G; Lewis, Cara C; Weiner, Bryan J

    2014-09-04

    Like many new fields, implementation science has become vulnerable to instrumentation issues that potentially threaten the strength of the developing knowledge base. For instance, many implementation studies report findings based on instruments that do not have established psychometric properties. This article aims to review six pressing instrumentation issues, discuss the impact of these issues on the field, and provide practical recommendations. This debate centers on the impact of the following instrumentation issues: use of frameworks, theories, and models; role of psychometric properties; use of 'home-grown' and adapted instruments; choosing the most appropriate evaluation method and approach; practicality; and need for decision-making tools. Practical recommendations include: use of consensus definitions for key implementation constructs; reporting standards (e.g., regarding psychometrics, instrument adaptation); when to use multiple forms of observation and mixed methods; and accessing instrument repositories and decision aid tools. This debate provides an overview of six key instrumentation issues and offers several courses of action to limit the impact of these issues on the field. With careful attention to these issues, the field of implementation science can potentially move forward at the rapid pace that is respectfully demanded by community stakeholders.

  16. Trainees' Perceptions of Feedback: Validity Evidence for Two FEEDME (Feedback in Medical Education) Instruments.

    PubMed

    Bing-You, Robert; Ramesh, Saradha; Hayes, Victoria; Varaklis, Kalli; Ward, Denham; Blanco, Maria

    2018-01-01

    Construct: Medical educators consider feedback a core component of the educational process. Effective feedback allows learners to acquire new skills, knowledge, and attitudes. Learners' perceptions of feedback are an important aspect to assess with valid methods in order to improve the feedback skills of educators and the feedback culture. Although guidelines for delivering effective feedback have existed for several decades, medical students and residents often indicate that they receive little feedback. A recent scoping review on feedback in medical education did not reveal any validity evidence on instruments to assess learner's perceptions of feedback. The purpose of our study was to gather validity evidence on two novel FEEDME (Feedback in Medical Education) instruments to assess medical students' and residents' perceptions of the feedback that they receive. After the authors developed an initial instrument with 54 items, cognitive interviews with medical students and residents suggested that 2 separate instruments were needed, one focused on the feedback culture (FEEDME-Culture) and the other on the provider of feedback (FEEDME-Provider). A Delphi study with 17 medical education experts and faculty members assessed content validity. The response process was explored involving 31 medical students and residents at 2 academic institutions. Exploratory factor analysis and reliability analyses were performed on completed instruments. Two Delphi consultation rounds refined the wording of items and eliminated several items. Learners found both instruments easy and quick to answer; it took them less than 5 minutes to complete. Learners preferred an electronic format of the instruments over paper. Factor analysis revealed a two- and three-factor solution for the FEEDME-Culture and FEEDME-Provider instruments, respectively. Cronbach's alpha was greater than 0.80 for all factors. Items on both instruments were moderately to highly correlated (range, r = .3-.7). Our

  17. Focused search of semantic cases: the effects of question form and case status.

    PubMed

    Singer, M; Jakobson, L S

    1989-05-01

    The present study was designed to identify and examine some of the variables that influence the focused search of semantic cases in question answering. Singer, Parbery, and Jakobson (1988) have previously reported that people can focus on the case interrogated by a question and can largely disregard irrelevant cases. In the present study, people learned facts, such as the pilot painted the garage with the roller, the spraygun, and the brush. One day later, they answered questions that focused on a particular case. For example, the question did the pilot paint with a spraygun? focuses on the instrument case. Experiment 1 revealed that people can focus on a particular case in response both to complete questions and to comparable word probes, such as "pilot spraygun." Therefore, the given-new structure of questions is not essential to focused search. Experiment 2 revealed that people have a difficult time ignoring the agent case, even when it is irrelevant to the question. This corroborates proposals that agent and action information are closely interrelated in the representation of a fact. These results help to delineate the phenomenon of the focused search of semantic cases.

  18. Using cognitive pre-testing methods in the development of a new evidenced-based pressure ulcer risk assessment instrument.

    PubMed

    Coleman, S; Nixon, J; Keen, J; Muir, D; Wilson, L; McGinnis, E; Stubbs, N; Dealey, C; Nelson, E A

    2016-11-16

    Variation in development methods of Pressure Ulcer Risk Assessment Instruments has led to inconsistent inclusion of risk factors and concerns about content validity. A new evidenced-based Risk Assessment Instrument, the Pressure Ulcer Risk Primary Or Secondary Evaluation Tool - PURPOSE-T was developed as part of a National Institute for Health Research (NIHR) funded Pressure Ulcer Research Programme (PURPOSE: RP-PG-0407-10056). This paper reports the pre-test phase to assess and improve PURPOSE-T acceptability, usability and confirm content validity. A descriptive study incorporating cognitive pre-testing methods and integration of service user views was undertaken over 3 cycles comprising PURPOSE-T training, a focus group and one-to-one think-aloud interviews. Clinical nurses from 2 acute and 2 community NHS Trusts, were grouped according to job role. Focus group participants used 3 vignettes to complete PURPOSE-T assessments and then participated in the focus group. Think-aloud participants were interviewed during their completion of PURPOSE-T. After each pre-test cycle analysis was undertaken and adjustment/improvements made to PURPOSE-T in an iterative process. This incorporated the use of descriptive statistics for data completeness and decision rule compliance and directed content analysis for interview and focus group data. Data were collected April 2012-June 2012. Thirty-four nurses participated in 3 pre-test cycles. Data from 3 focus groups, 12 think-aloud interviews incorporating 101 PURPOSE-T assessments led to changes to improve instrument content and design, flow and format, decision support and item-specific wording. Acceptability and usability were demonstrated by improved data completion and appropriate risk pathway allocation. The pre-test also confirmed content validity with clinical nurses. The pre-test was an important step in the development of the preliminary PURPOSE-T and the methods used may have wider instrument development application

  19. Development of a survey instrument to measure connectivity to evaluate national public health preparedness and response performance.

    PubMed

    Dorn, Barry C; Savoia, Elena; Testa, Marcia A; Stoto, Michael A; Marcus, Leonard J

    2007-01-01

    Survey instruments for evaluating public health preparedness have focused on measuring the structure and capacity of local, state, and federal agencies, rather than linkages among structure, process, and outcomes. To focus evaluation on the latter, we evaluated the linkages among individuals, organizations, and systems using the construct of "connectivity" and developed a measurement instrument. Results from focus groups of emergency preparedness first responders generated 62 items used in the development sample of 187 respondents. Item reduction and factors analyses were conducted to confirm the scale's components. The 62 items were reduced to 28. Five scales explained 70% of the total variance (number of items, percent variance explained, Cronbach's alpha) including connectivity with the system (8, 45%, 0.94), coworkers (7, 7%, 0.91), organization (7, 12%, 0.93), and perceptions (6, 6%, 0.90). Discriminant validity was found to be consistent with the factor structure. We developed a Connectivity Measurement Tool for the public health workforce consisting of a 34-item questionnaire found to be a reliable measure of connectivity with preliminary evidence of construct validity.

  20. The Focusing Optics X-ray Solar Imager (FOXSI) SMEX Mission

    NASA Astrophysics Data System (ADS)

    Christe, S.; Shih, A. Y.; Krucker, S.; Glesener, L.; Saint-Hilaire, P.; Caspi, A.; Allred, J. C.; Battaglia, M.; Chen, B.; Drake, J. F.; Gary, D. E.; Goetz, K.; Grefenstette, B.; Hannah, I. G.; Holman, G.; Hudson, H. S.; Inglis, A. R.; Ireland, J.; Ishikawa, S. N.; Klimchuk, J. A.; Kontar, E.; Kowalski, A. F.; Massone, A. M.; Piana, M.; Ramsey, B.; Gubarev, M.; Schwartz, R. A.; Steslicki, M.; Ryan, D.; Turin, P.; Warmuth, A.; White, S. M.; Veronig, A.; Vilmer, N.; Dennis, B. R.

    2016-12-01

    We present FOXSI (Focusing Optics X-ray Solar Imager), a recently proposed Small Explorer (SMEX) mission that will provide a revolutionary new perspective on energy release and particle acceleration on the Sun. FOXSI is a direct imaging X-ray spectrometer with higher dynamic range and better than 10x the sensitivity of previous instruments. Flown on a 3-axis stabilized spacecraft in low-Earth orbit, FOXSI uses high-angular-resolution grazing-incidence focusing optics combined with state-of-the-art pixelated solid-state detectors to provide direct imaging of solar hard X-rays for the first time. FOXSI is composed of two individual x-ray telescopes with a 14-meter focal length enabled by a deployable boom. Making use of a filter-wheel and high-rate-capable solid-state detectors, FOXSI will be able to observe the largest flares without saturation while still maintaining the sensitivity to detect x-ray emission from weak flares, escaping electrons, and hot active regions. This SMEX mission is made possible by past experience with similar instruments on two sounding rocket flights, in 2012 and 2014, and on the HEROES balloon flight in 2013. FOXSI will image the Sun with a field of view of 9 arcminutes and an angular resolution of better than 8 arcsec; it will cover the energy range from 3 to 100 keV with a spectral resolution of better than 1 keV; and it will have sub-second temporal resolution.

  1. Contamination design of a Scientific Instrument Protective Enclosure for the Hubble Space Telescope Servicing Mission

    NASA Technical Reports Server (NTRS)

    Hedgeland, Randy J.; Hansen, Patricia A.

    1993-01-01

    A Scientific Instrument Protective Enclosure (SIPE) was designed to accommodate second generation science instruments (SIs) for the Hubble Space Telescope (HST) First Servicing Mission (FSM). One of the main design drivers for the SIPE is to provide a protective environment for the SIs against particulate and molecular contaminants that pose a viable threat to the SI performance. The focus of this paper will detail the methodology incorporated in the design of the SIPE to provide a controlled environment for SI protection at the launch site, during pre-launch/launch activities, and during on-orbit operations in the Shuttle bay.

  2. Wet chemistry instrument prototype

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A wet chemistry instrument prototype for detecting amino acids in planetary soil samples was developed. The importance of amino acids and their condensation products to the development of life forms is explained. The characteristics of the instrument and the tests which were conducted to determine the materials compatibility are described. Diagrams are provided to show the construction of the instrument. Data obtained from the performance tests are reported.

  3. Respiratory function in wind instrument players.

    PubMed

    Zuskin, Eugenija; Mustajbegovic, Jadranka; Schachter, E N; Kern, Josipa; Vitale, Ksenija; Pucarin-Cvetkovic, Jasna; Chiarelli, A; Milosevic, M; Jelinic, Jagoda Doko

    2009-01-01

    The playing of wind instruments has been associated with changes in respiratory function. To investigate the effect of playing wind instruments on lung function and respiratory symptoms. The present study included 99 wind instrument players and a group of 41 string instrument players as a control from 3 major orchestras in Zagreb, Croatia. Data on chronic respiratory symptoms were recorded in all studied subjects. Lung function was measured in wind instrument players by recording maximum expiratory flow-volume curves. Wind instrument players demonstrated significantly higher prevalences of sinusitis, nasal catarrh and hoarseness compared to control musicians. One wind instrument player developed asthma associated with his work. Odds ratios for wind instrument players were significant for chronic cough, chronic phlegm and chronic bronchitis by smoking habit (p<0.05 or p<0.01) but not for length of employment. Ventilatory capacity data indicate that wind instrument players had significantly greater FEV1 (smokers and nonsmokers) as well as FEF50 (nonsmokers) (p<0.05) compared to predicted values. Regression analysis of pulmonary function tests in wind instrument players demonstrate a significant link between FEV1 and FEF50 and length of employment. Those wind instrument players with longer employment had the greatest increases in lung function. Our data suggest that musicians playing wind instruments may be susceptible to chronic upper airway symptoms. Interestingly wind instrument playing may be associated with higher than expected lung function parameters.

  4. TES Instrument Decommissioning

    Atmospheric Science Data Center

    2018-03-20

    TES Instrument Decommissioning Tuesday, March 20, 2018 ... PST during a scheduled real time satellite contact the TES IOT along with the Aura FOT commanded the TES instrument to its ... generated from an algorithm update to the base Ground Data System software and will be made available to the scientific community in the ...

  5. Application of Bother in patient reported outcomes instruments across cultures

    PubMed Central

    2014-01-01

    Background The objective of this study was to determine the applicability of the term bother, as used in Patient Reported Outcomes (PRO) instruments that will be translated into foreign languages from English for the United States. Bother is versatile in English for the U.S., in that it can describe negative mental states and physical sensations, as well as social disturbances. Bother has many different meanings across cultures, due to this versatility. Alternatives for bother were explored for future PRO instrument development. Methods A PRO instrument used to evaluate the degree of bother resulting from psoriasis was analyzed. This disease can negatively impact patients physically, emotionally and socially. Translations of bother were analyzed to determine its meaning when translated into other languages. Cognitive debriefing was conducted on psoriasis patients with the instrument containing bother. Following cognitive debriefing, a questionnaire was distributed to linguists and cognitive debriefing subjects to collect definitions of bother in each target language, and detail any difficulty with translation. To establish alternatives to bother and demonstrate the breakdown of concepts within bother, translations of the Dermatology Quality of Life Index (DLQI) were analyzed. This instrument was selected for its focus on psoriasis and use of terminology that lacks the ambiguity of bother. Results An analysis of back-translations revealed that bother yielded a back-translation that was conceptually different from the source 20% of the time (5/26). Analysis of alternative terminology found in the DLQI revealed much greater conceptual equivalence when translated into other languages. Conclusion When developing the wording of PRO instruments, the terminology chosen should be applicable across languages to allow for international pooling and comparison of data. While all linguists and subjects of cognitive debriefing understood bother to have a negative connotation, a

  6. Current status of the facility instrumentation suite at the Large Binocular Telescope Observatory

    NASA Astrophysics Data System (ADS)

    Rothberg, Barry; Kuhn, Olga; Edwards, Michelle L.; Hill, John M.; Thompson, David; Veillet, Christian; Wagner, R. Mark

    2016-07-01

    The current status of the facility instrumentation for the Large Binocular Telescope (LBT) is reviewed. The LBT encompasses two 8.4 meter primary mirrors on a single mount yielding an effective collecting area of 11.8 meters or 23 meters when interferometrically combined. The three facility instruments at LBT include: 1) the Large Binocular Cameras (LBCs), each with a 23'× 25' field of view (FOV). The blue optimized and red optimized optical wavelength LBCs are mounted at the prime focus of the SX (left) and DX (right) primary mirrors, respectively. Combined, the filter suite of the two LBCs cover 0.3-1.1 μm, including the addition of new medium-band filters centered on TiO (0.78 μm) and CN (0.82 μm) 2) the Multi-Object Double Spectrograph (MODS), two identical optical spectrographs each mounted at the straight through f/15 Gregorian focus of the primary mirrors. The capabilities of MODS-1 and -2 include imaging with Sloan filters (u, g, r, i, and z) and medium resolution (R ˜ 2000) spectroscopy, each with 24 interchangeable masks (multi-object or longslit) over a 6'× 6' FOV. Each MODS is capable of blue (0.32-0.6 μm) and red (0.5-1.05 μm) wavelength only spectroscopy coverage or both can employ a dichroic for 0.32-1.05 μm wavelength coverage (with reduced coverage from 0.56- 0.57 μm) and 3) the two LBT Utility Camera in the Infrared instruments (LUCIs), are each mounted at a bent-front Gregorian f/15 focus of a primary mirror. LUCI-1 and 2 are designed for seeing-limited (4'× 4' FOV) and active optics using thin-shell adaptive secondary mirrors (0.5'× 0.5' FOV) imaging and spectroscopy over the wavelength range of 0.95-2.5 μm and spectroscopic resolutions of 400 <= R <= 11000 (depending on the combination of grating, slits, and cameras used). The spectroscopic capabilities also include 32 interchangeable multi-object or longslit masks which are cryogenically cooled. Currently all facility instruments are in-place at the LBT and, for the first time

  7. Aircraft Power-Plant Instruments

    NASA Technical Reports Server (NTRS)

    Sontag, Harcourt; Brombacher, W G

    1934-01-01

    This report supersedes NACA-TR-129 which is now obsolete. Aircraft power-plant instruments include tachometers, engine thermometers, pressure gages, fuel-quantity gages, fuel flow meters and indicators, and manifold pressure gages. The report includes a description of the commonly used types and some others, the underlying principle utilized in the design, and some design data. The inherent errors of the instrument, the methods of making laboratory tests, descriptions of the test apparatus, and data in considerable detail in the performance of commonly used instruments are presented. Standard instruments and, in cases where it appears to be of interest, those used as secondary standards are described. A bibliography of important articles is included.

  8. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    PubMed

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  9. Outcomes for implementation science: an enhanced systematic review of instruments using evidence-based rating criteria.

    PubMed

    Lewis, Cara C; Fischer, Sarah; Weiner, Bryan J; Stanick, Cameo; Kim, Mimi; Martinez, Ruben G

    2015-11-04

    High-quality measurement is critical to advancing knowledge in any field. New fields, such as implementation science, are often beset with measurement gaps and poor quality instruments, a weakness that can be more easily addressed in light of systematic review findings. Although several reviews of quantitative instruments used in implementation science have been published, no studies have focused on instruments that measure implementation outcomes. Proctor and colleagues established a core set of implementation outcomes including: acceptability, adoption, appropriateness, cost, feasibility, fidelity, penetration, sustainability (Adm Policy Ment Health Ment Health Serv Res 36:24-34, 2009). The Society for Implementation Research Collaboration (SIRC) Instrument Review Project employed an enhanced systematic review methodology (Implement Sci 2: 2015) to identify quantitative instruments of implementation outcomes relevant to mental or behavioral health settings. Full details of the enhanced systematic review methodology are available (Implement Sci 2: 2015). To increase the feasibility of the review, and consistent with the scope of SIRC, only instruments that were applicable to mental or behavioral health were included. The review, synthesis, and evaluation included the following: (1) a search protocol for the literature review of constructs; (2) the literature review of instruments using Web of Science and PsycINFO; and (3) data extraction and instrument quality ratings to inform knowledge synthesis. Our evidence-based assessment rating criteria quantified fundamental psychometric properties as well as a crude measure of usability. Two independent raters applied the evidence-based assessment rating criteria to each instrument to generate a quality profile. We identified 104 instruments across eight constructs, with nearly half (n = 50) assessing acceptability and 19 identified for adoption, with all other implementation outcomes revealing fewer than 10

  10. Focusing experiments in plasma coaxial railguns

    NASA Astrophysics Data System (ADS)

    Driga, M. D.; Cook, R. W.; Thelen, R. F.

    1986-11-01

    Results are reported from experiments on focusing of plasma fired from a coaxial electromagnetic gun (CEMG). The plasma used, obtained by exploding a metallic fuse at the gun breech, comprised metal vapor, metallic liquid droplets and small chunks of solid metal. An azimuthal current, and thereby an axial field, was introduced at the breech of the CEMG by a solenoid. Previous studies indicated that the field would cause vaporized metal to form into a self-stabilizing toroidal plasma. Test shots instrumented with Languir probes and pick-up coils did not reveal the presence of toroidal plasma rings. However, post-mortem of the 30 cm rail showed that only one-third of the 3 mg Al fuse metal remained in the bore. Further, a toroidal hole was punched in a diagnostic screen at the bore exit after one shot.

  11. Medical instrument data exchange.

    PubMed

    Gumudavelli, Suman; McKneely, Paul K; Thongpithoonrat, Pongnarin; Gurkan, D; Chapman, Frank M

    2008-01-01

    Advances in medical devices and health care has been phenomenal during the recent years. Although medical device manufacturers have been improving their instruments, network connection of these instruments still rely on proprietary technologies. Even if the interface has been provided by the manufacturer (e.g., RS-232, USB, or Ethernet coupled with a proprietary API), there is no widely-accepted uniform data model to access data of various bedside instruments. There is a need for a common standard which allows for internetworking with the medical devices from different manufacturers. ISO/IEEE 11073 (X73) is a standard attempting to unify the interfaces of all medical devices. X73 defines a client access mechanism that would be implemented into the communication controllers (residing between an instrument and the network) in order to access/network patient data. On the other hand, MediCAN technology suite has been demonstrated with various medical instruments to achieve interfacing and networking with a similar goal in its open standardization approach. However, it provides a more generic definition for medical data to achieve flexibility for networking and client access mechanisms. In this paper, a comparison between the data model of X73 and MediCAN will be presented to encourage interoperability demonstrations of medical instruments.

  12. How discriminating are discriminative instruments?

    PubMed

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  13. Performances and first science results with the VEGA/CHARA visible instrument

    NASA Astrophysics Data System (ADS)

    Mourard, D.; Tallon, M.; Bério, Ph.; Bonneau, D.; Chesneau, O.; Clausse, J. M.; Delaa, O.; Nardetto, N.; Perraut, K.; Spang, A.; Stee, Ph.; Tallon-Bosc, I.; McAlister, H.; ten Brummelaar, T.; Sturmann, J.; Sturmann, L.; Turner, N.; Farrington, C.; Goldfinger, P. J.

    2010-07-01

    This paper presents the current status of the VEGA (Visible spEctroGraph and polArimeter) instrument installed at the coherent focus of the CHARA Array, Mount Wilson CA. Installed in september 2007, the first science programs have started during summer 2008 and first science results are now published. Dedicated to high angular (0.3mas) and high spectral (R=30000) astrophysical studies, VEGA main objectives are the study of circumstellar environments of hot active stars or interactive binary systems and a large palette of new programs dedicated to fundamental stellar parameters. We will present successively the main characteristics of the instrument and its current performances in the CHARA environment, a short summary of two science programs and finally we will develop some studies showing the potential and difficulties of the 3 telescopes mode of VEGA/CHARA.

  14. Atomically precise (catalytic) particles synthesized by a novel cluster deposition instrument

    DOE PAGES

    Yin, C.; Tyo, E.; Kuchta, K.; ...

    2014-05-06

    Here, we report a new high vacuum instrument which is dedicated to the preparation of well-defined clusters supported on model and technologically relevant supports for catalytic and materials investigations. The instrument is based on deposition of size selected metallic cluster ions that are produced by a high flux magnetron cluster source. Furthermore, we maximize the throughput of the apparatus by collecting and focusing ions utilizing a conical octupole ion guide and a linear ion guide. The size selection is achieved by a quadrupole mass filter. The new design of the sample holder provides for the preparation of multiple samples onmore » supports of various sizes and shapes in one session. After cluster deposition onto the support of interest, samples will be taken out of the chamber for a variety of testing and characterization.« less

  15. Instrument for underwater high-angular resolution volume scattering function measurements

    NASA Astrophysics Data System (ADS)

    Dueweke, Paul W.; Bolstad, Jay; Leonard, Donald A.; Sweeney, Harold E.; Boyer, Philip A.; Winkler, Erik M.

    1997-02-01

    A prototype instrument for in situ measurements of the volume scattering function (VSF) and the beam attenuation of water has been built and tested in the EOO laboratory. The intended application of the instrument is the enhancement of Navy operational optical systems for finding and imaging underwater objects such as mines. A description of the apparatus that was built and preliminary laboratory data will be presented. The instrument measures the VSF, (beta) ((theta) ), near the optical axis in both the forward and back directions from approximately 0.2 degrees off axis to approximately 5 degrees in 0.1 degree steps and at side angles of 45 degrees, 90 degrees, and 135 degrees. A diode- pumped, frequency-doubled, Nd:YAG laser provides the 532 nm light. This is the most used wavelength for underwater optical systems. The forward and back scattered light is collected and focused to a plane where scattering angles in the water are mapped onto concentric rings. At this focal plane, a conical reflector compresses the annular optical data onto a line along the cone axis where it is read by a MOS linear image array providing over 500 separate angular measurements. The beam attenuation coefficient, c, is also measured by means of a unique dual path configuration.

  16. Subminiaturization for ERAST instrumentation (Environmental Research Aircraft and Sensor Technology)

    NASA Technical Reports Server (NTRS)

    Madou, Marc; Lowenstein, Max; Wegener, Steven

    1995-01-01

    We are focusing on the Argus as an example to demonstrate our philosophy on miniaturization of airborne analytical instruments for the study of atmospheric chemistry. Argus is a two channel, tunable-diode laser absorption spectrometer developed at NASA for the measurement of nitrogen dioxide (N2O) (4.5 micrometers) and ammonia (CH3) (3.3 micrometers) at the 0.1 parts per billion (ppb) level from the Perseus aircraft platform at altitudes up to 30 km. Although Argus' mass is down to 23 kg from the 197 kg Atlas, its predecessor, our goal is to design a next-generation subminiaturized instrument weighing less than 1 kg, measuring a few cm(exp 3) and able to eliminate dewars for cooling. Current designs enable use to make a small,inexpensive, monolithic spectrometer without the required sensitivity range. Further work is on its way to increase sensitivity. We are continuing to zero-base the technical approach in terms of the specifications for the given instrument. We are establishing a check list of questions to hone into the best micromachining approach and to superpose on the answers insights in scaling laws and flexible engineering designs to enable more relaxed tolerances for the smallest of the components.

  17. Mini-Laparoscopy: Instruments and Economics.

    PubMed

    Shadduck, Phillip P; Paquentin, Eduardo Moreno; Carvalho, Gustavo L; Redan, Jay A

    2015-11-01

    Mini-laparoscopy (Mini) was pioneered more than 20 years ago, initially with instruments borrowed from other specialties and subsequently with tools designed specifically for Mini. Early adoption of Mini was inhibited though by the limitations of these first-generation instruments, especially functionality and durability. Newer generation Mini instruments have recently become available with improved effector tips, a choice of shaft diameters and lengths, better shaft insulation and electrosurgery capability, improved shaft strength and rotation, more ergonomic handles, low-friction trocar options, and improved instrument durability. Improvements are also occurring in imaging and advanced energy for Mini. The current status of mini-laparoscopy instruments and economics are presented.

  18. Innovative technology in hearing instruments: matching needs in the developing world.

    PubMed

    McPherson, Bradley

    2011-12-01

    Hearing instrument technology research is almost entirely focused on the projected needs of the consumer market in the developed world. However, two thirds of the world's population with hearing impairment live in developing countries and this proportion will increase in future, given present demographic trends. In developing regions, amplification and other hearing health needs may differ from those in industrialized nations, for cultural, health, or economic reasons. World Health Organization estimates indicate that at present only a small percentage of individuals in developing countries who are in need of amplification have access to hearing aid provision. New technologies, such as trainable hearing aids, advanced noise reduction algorithms, feedback reduction circuitry, nano coatings for hearing aid components, and innovative power options, may offer considerable potential benefits, both for individuals with hearing impairment in developing countries and for those who provide hearing health care services in these regions. This article considers the possible supporting role of innovative hearing instrument technologies in the provision of affordable hearing health care services in developing countries and highlights the need for research that considers the requirements of the majority of the world population in need of hearing instrument provision.

  19. Construction and Validation of an Instrument to Measure Taiwanese Elementary Students' Attitudes toward Their Science Class

    NASA Astrophysics Data System (ADS)

    Wang, Tzu-Ling; Berlin, Donna

    2010-12-01

    The main purpose of this study is to develop a valid and reliable instrument for measuring the attitudes toward science class of fourth- and fifth-grade students in an Asian school culture. Specifically, the development focused on three science attitude constructs-science enjoyment, science confidence, and importance of science as related to science class experiences. A total of 265 elementary school students in Taiwan responded to the instrument developed. Data analysis indicated that the instrument exhibited satisfactory validity and reliability with the Taiwan population used. The Cronbach's alpha coefficient was 0.93 for the entire instrument indicating a satisfactory level of internal consistency. However, both principal component analysis and parallel analysis showed that the three attitude scales were not unique and should be combined and used as a general "attitudes toward science class" scale. The analysis also showed that there were no gender or grade-level differences in students' overall attitudes toward science class.

  20. Are Beginning Teachers Ready for the Job? The Development and Validation of an Instrument to Measure the Basic Skills of Beginning Secondary Teachers

    ERIC Educational Resources Information Center

    Struyf, Elke; Adriaensens, Stefanie; Meynen, Karen

    2011-01-01

    Society has become more complex in recent decades, and this has increased the demands placed on the educational system and the teaching profession. This study focuses on the development and validation of an instrument that measures the basic skills of beginning teachers. The instrument was developed according to scientific knowledge on teacher…

  1. Comparing CALL and VAL-ED: An Illustrative Application of a Decision Matrix for Selecting Among Leadership Feedback Instruments. WCER Working Paper No. 2015-5

    ERIC Educational Resources Information Center

    Goff, Peter; Salisbury, Jason; Blitz, Mark

    2015-01-01

    Initiatives to increase leadership accountability coupled with efforts to promote data-driven leadership have led to widespread adoption of instruments to assess school leaders. In this paper we present a decision matrix that practitioners and researchers can use to facilitate instrument selection. Our decision matrix focuses on the psychometric…

  2. Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty.

    PubMed

    Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J

    2018-01-01

    Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.

  3. Discriminative stimuli that control instrumental tobacco-seeking by human smokers also command selective attention.

    PubMed

    Hogarth, Lee; Dickinson, Anthony; Duka, Theodora

    2003-08-01

    Incentive salience theory states that acquired bias in selective attention for stimuli associated with tobacco-smoke reinforcement controls the selective performance of tobacco-seeking and tobacco-taking behaviour. To support this theory, we assessed whether a stimulus that had acquired control of a tobacco-seeking response in a discrimination procedure would command the focus of visual attention in a subsequent test phase. Smokers received discrimination training in which an instrumental key-press response was followed by tobacco-smoke reinforcement when one visual discriminative stimulus (S+) was present, but not when another stimulus (S-) was present. The skin conductance response to the S+ and S- assessed whether Pavlovian conditioning to the S+ had taken place. In a subsequent test phase, the S+ and S- were presented in the dot-probe task and the allocation of the focus of visual attention to these stimuli was measured. Participants learned to perform the instrumental tobacco-seeking response selectively in the presence of the S+ relative to the S-, and showed a greater skin conductance response to the S+ than the S-. In the subsequent test phase, participants allocated the focus of visual attention to the S+ in preference to the S-. Correlation analysis revealed that the visual attentional bias for the S+ was positively associated with the number of times the S+ had been paired with tobacco-smoke in training, the skin conductance response to the S+ and with subjective craving to smoke. Furthermore, increased exposure to tobacco-smoke in the natural environment was associated with reduced discrimination learning. These data demonstrate that discriminative stimuli that signal that tobacco-smoke reinforcement is available acquire the capacity to command selective attentional and elicit instrumental tobacco-seeking behaviour.

  4. A collection of sub-daily pressure and temperature observations for the early instrumental period with a focus on the "year without a summer" 1816

    NASA Astrophysics Data System (ADS)

    Brugnara, Y.; Auchmann, R.; Brönnimann, S.; Allan, R. J.; Auer, I.; Barriendos, M.; Bergström, H.; Bhend, J.; Brázdil, R.; Compo, G. P.; Cornes, R. C.; Dominguez-Castro, F.; van Engelen, A. F. V.; Filipiak, J.; Holopainen, J.; Jourdain, S.; Kunz, M.; Luterbacher, J.; Maugeri, M.; Mercalli, L.; Moberg, A.; Mock, C. J.; Pichard, G.; Řezníčková, L.; van der Schrier, G.; Slonosky, V.; Ustrnul, Z.; Valente, M. A.; Wypych, A.; Yin, X.

    2015-08-01

    The eruption of Mount Tambora (Indonesia) in April 1815 is the largest documented volcanic eruption in history. It is associated with a large global cooling during the following year, felt particularly in parts of Europe and North America, where the year 1816 became known as the "year without a summer". This paper describes an effort made to collect surface meteorological observations from the early instrumental period, with a focus on the years of and immediately following the eruption (1815-1817). Although the collection aimed in particular at pressure observations, correspondent temperature observations were also recovered. Some of the series had already been described in the literature, but a large part of the data, recently digitised from original weather diaries and contemporary magazines and newspapers, is presented here for the first time. The collection puts together more than 50 sub-daily series from land observatories in Europe and North America and from ships in the tropics. The pressure observations have been corrected for temperature and gravity and reduced to mean sea level. Moreover, an additional statistical correction was applied to take into account common error sources in mercury barometers. To assess the reliability of the corrected data set, the variance in the pressure observations is compared with modern climatologies, and single observations are used for synoptic analyses of three case studies in Europe. All raw observations will be made available to the scientific community in the International Surface Pressure Databank.

  5. Research Instruments

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The GENETI-SCANNER, newest product of Perceptive Scientific Instruments, Inc. (PSI), rapidly scans slides, locates, digitizes, measures and classifies specific objects and events in research and diagnostic applications. Founded by former NASA employees, PSI's primary product line is based on NASA image processing technology. The instruments karyotype - a process employed in analysis and classification of chromosomes - using a video camera mounted on a microscope. Images are digitized, enabling chromosome image enhancement. The system enables karyotyping to be done significantly faster, increasing productivity and lowering costs. Product is no longer being manufactured.

  6. Content validity--establishing and reporting the evidence in newly developed patient-reported outcomes (PRO) instruments for medical product evaluation: ISPOR PRO good research practices task force report: part 1--eliciting concepts for a new PRO instrument.

    PubMed

    Patrick, Donald L; Burke, Laurie B; Gwaltney, Chad J; Leidy, Nancy Kline; Martin, Mona L; Molsen, Elizabeth; Ring, Lena

    2011-12-01

    The importance of content validity in developing patient reported outcomes (PRO) instruments is stressed by both the US Food and Drug Administration and the European Medicines Agency. Content validity is the extent to which an instrument measures the important aspects of concepts that developers or users purport it to assess. A PRO instrument measures the concepts most significant and relevant to a patient's condition and its treatment. For PRO instruments, items and domains as reflected in the scores of an instrument should be important to the target population and comprehensive with respect to patient concerns. Documentation of target population input in item generation, as well as evaluation of patient understanding through cognitive interviewing, can provide the evidence for content validity. Developing content for, and assessing respondent understanding of, newly developed PRO instruments for medical product evaluation will be discussed in this two-part ISPOR PRO Good Research Practices Task Force Report. Topics include the methods for generating items, documenting item development, coding of qualitative data from item generation, cognitive interviewing, and tracking item development through the various stages of research and preparing this tracking for submission to regulatory agencies. Part 1 covers elicitation of key concepts using qualitative focus groups and/or interviews to inform content and structure of a new PRO instrument. Part 2 covers the instrument development process, the assessment of patient understanding of the draft instrument using cognitive interviews and steps for instrument revision. The two parts are meant to be read together. They are intended to offer suggestions for good practices in planning, executing, and documenting qualitative studies that are used to support the content validity of PRO instruments to be used in medical product evaluation. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR

  7. The Business of Experimental Physics: Instrument Makers and Itinerant Lecturers in the German Enlightenment

    NASA Astrophysics Data System (ADS)

    Hochadel, Oliver

    2007-06-01

    While it is a commonplace in the historiography of electricity that itinerant lecturers and instrument makers were `somehow' part of the `electrical flare' of the 18th century, very little is actually known about them, about their background, their careers and their self-understanding. Yet, research focusing on these practitioners of experimental physics outside the established institutions can contribute immensely to our understanding of the scientific culture of the Enlightenment. The development of electrical machines, the supply for increasing demand for instruments and instruction, the creation of interest in electricity through public demonstrations, relied heavily on these men. Furthermore, these `scientific salesmen' offered a perfect contrast, a foil for the natural philosophers from whom to distinguish themselves. Natural philosophers tried to discredit their extra-academic competitors, thereby forging their own image as serious, honest, truth-seeking, independent researchers. This essay focuses on this situation in the German Empire, tracing the steps of the itinerant lecturer Jakob von Bianchy on his way from court to college, from the workshop to the theatre, from Lake Como, to Vienna and Paris.

  8. Low-kilovolt coherent electron diffractive imaging instrument based on a single-atom electron source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Chun-Yueh; Chang, Wei-Tse; Chen, Yi-Sheng

    2016-03-15

    In this work, a transmission-type, low-kilovolt coherent electron diffractive imaging instrument was constructed. It comprised a single-atom field emitter, a triple-element electrostatic lens, a sample holder, and a retractable delay line detector to record the diffraction patterns at different positions behind the sample. It was designed to image materials thinner than 3 nm. The authors analyzed the asymmetric triple-element electrostatic lens for focusing the electron beams and achieved a focused beam spot of 87 nm on the sample plane at the electron energy of 2 kV. High-angle coherent diffraction patterns of a suspended graphene sample corresponding to (0.62 Å){sup −1} were recorded. This workmore » demonstrated the potential of coherent diffractive imaging of thin two-dimensional materials, biological molecules, and nano-objects at a voltage between 1 and 10 kV. The ultimate goal of this instrument is to achieve atomic resolution of these materials with high contrast and little radiation damage.« less

  9. AMICA (Antarctic Multiband Infrared CAmera) project

    NASA Astrophysics Data System (ADS)

    Dolci, Mauro; Straniero, Oscar; Valentini, Gaetano; Di Rico, Gianluca; Ragni, Maurizio; Pelusi, Danilo; Di Varano, Igor; Giuliani, Croce; Di Cianno, Amico; Valentini, Angelo; Corcione, Leonardo; Bortoletto, Favio; D'Alessandro, Maurizio; Bonoli, Carlotta; Giro, Enrico; Fantinel, Daniela; Magrin, Demetrio; Zerbi, Filippo M.; Riva, Alberto; Molinari, Emilio; Conconi, Paolo; De Caprio, Vincenzo; Busso, Maurizio; Tosti, Gino; Nucciarelli, Giuliano; Roncella, Fabio; Abia, Carlos

    2006-06-01

    The Antarctic Plateau offers unique opportunities for ground-based Infrared Astronomy. AMICA (Antarctic Multiband Infrared CAmera) is an instrument designed to perform astronomical imaging from Dome-C in the near- (1 - 5 μm) and mid- (5 - 27 μm) infrared wavelength regions. The camera consists of two channels, equipped with a Raytheon InSb 256 array detector and a DRS MF-128 Si:As IBC array detector, cryocooled at 35 and 7 K respectively. Cryogenic devices will move a filter wheel and a sliding mirror, used to feed alternatively the two detectors. Fast control and readout, synchronized with the chopping secondary mirror of the telescope, will be required because of the large background expected at these wavelengths, especially beyond 10 μm. An environmental control system is needed to ensure the correct start-up, shut-down and housekeeping of the camera. The main technical challenge is represented by the extreme environmental conditions of Dome C (T about -90 °C, p around 640 mbar) and the need for a complete automatization of the overall system. AMICA will be mounted at the Nasmyth focus of the 80 cm IRAIT telescope and will perform survey-mode automatic observations of selected regions of the Southern sky. The first goal will be a direct estimate of the observational quality of this new highly promising site for Infrared Astronomy. In addition, IRAIT, equipped with AMICA, is expected to provide a significant improvement in the knowledge of fundamental astrophysical processes, such as the late stages of stellar evolution (especially AGB and post-AGB stars) and the star formation.

  10. Guide to Scientific Instruments

    ERIC Educational Resources Information Center

    Sommer, Richard G.; Scherago, Earl J.

    1977-01-01

    Provides a list of scientific laboratory instruments and equipment and the names and addresses of their manufacturers. Instruments appear in alphabetical order with the names of manufactures listed below each. (SL)

  11. Cervical Spine Instrumentation in Children.

    PubMed

    Hedequist, Daniel J; Emans, John B

    2016-06-01

    Instrumentation of the cervical spine enhances stability and improves arthrodesis rates in children undergoing surgery for deformity or instability. Various morphologic and clinical studies have been conducted in children, confirming the feasibility of anterior or posterior instrumentation of the cervical spine with modern implants. Knowledge of the relevant spine anatomy and preoperative imaging studies can aid the clinician in understanding the pitfalls of instrumentation for each patient. Preoperative planning, intraoperative positioning, and adherence to strict surgical techniques are required given the small size of children. Instrumentation options include anterior plating, occipital plating, and a variety of posterior screw techniques. Complications related to screw malposition include injury to the vertebral artery, neurologic injury, and instrumentation failure.

  12. The 64 Mpixel wide field imager for the Wendelstein 2m telescope: design and calibration

    NASA Astrophysics Data System (ADS)

    Kosyra, Ralf; Gössl, Claus; Hopp, Ulrich; Lang-Bardl, Florian; Riffeser, Arno; Bender, Ralf; Seitz, Stella

    2014-11-01

    The Wendelstein Observatory of Ludwig Maximilians University of Munich has recently been upgraded with a modern 2m robotic telescope. One Nasmyth port of the telescope has been equipped with a wide-field corrector which preserves the excellent image quality (<0.8 " median seeing) of the site (Hopp et al. 2008) over a field of view of 0.7 degrees diameter. The available field is imaged by an optical imager (WWFI, the Wendelstein Wide Field Imager) built around a customized 2×2 mosaic of 4 k×4 k 15 μm e2v CCDs from Spectral Instruments. This paper provides an overview of the design and the WWFI's performance. We summarize the system mechanics (including a structural analysis), the electronics (and its electromagnetic interference (EMI) protection) and the control software. We discuss in detail detector system parameters, i.e. gain and readout noise, quantum efficiency as well as charge transfer efficiency (CTE) and persistent charges. First on sky tests yield overall good predictability of system throughput based on lab measurements.

  13. Disease-specific health-related quality of life instruments for IgE-mediated food allergy.

    PubMed

    Salvilla, S A; Dubois, A E J; Flokstra-de Blok, B M J; Panesar, S S; Worth, A; Patel, S; Muraro, A; Halken, S; Hoffmann-Sommergruber, K; DunnGalvin, A; Hourihane, J O'B; Regent, L; de Jong, N W; Roberts, G; Sheikh, A

    2014-07-01

    This is one of seven interlinked systematic reviews undertaken on behalf of the European Academy of Allergy and Clinical Immunology as part of their Guidelines for Food Allergy and Anaphylaxis, which focuses on instruments developed for IgE-mediated food allergy. Disease-specific questionnaires are significantly more sensitive than generic ones in measuring the response to interventions or future treatments, as well as estimating the general burden of food allergy. The aim of this systematic review was therefore to identify which disease-specific, validated instruments can be employed to enable assessment of the impact of, and investigations and interventions for, IgE-mediated food allergy on health-related quality of life (HRQL). Using a sensitive search strategy, we searched seven electronic bibliographic databases to identify disease-specific quality of life (QOL) tools relating to IgE-mediated food allergy. From the 17 eligible studies, we identified seven disease-specific HRQL instruments, which were then subjected to detailed quality appraisal. This revealed that these instruments have undergone formal development and validation processes, and have robust psychometric properties, and therefore provide a robust means of establishing the impact of food allergy on QOL. Suitable instruments are now available for use in children, adolescents, parents/caregivers, and adults. Further work must continue to develop a clinical minimal important difference for food allergy and for making these instruments available in a wider range of European languages. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. A Systematic Review of Instruments to Assess Organizational Readiness for Knowledge Translation in Health Care

    PubMed Central

    Gagnon, Marie-Pierre; Attieh, Randa; Ghandour, El Kebir; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A.; Grimshaw, Jeremy

    2014-01-01

    Background The translation of research into practices has been incomplete. Organizational readiness for change (ORC) is a potential facilitator of effective knowledge translation (KT). However we know little about the best way to assess ORC. Therefore, we sought to systematically review ORC measurement instruments. Methods We searched for published studies in bibliographic databases (Pubmed, Embase, CINAHL, PsychINFO, Web of Science, etc.) up to November 1st, 2012. We included publications that developed ORC measures and/or empirically assessed ORC using an instrument at the organizational level in the health care context. We excluded articles if they did not refer specifically to ORC, did not concern the health care domain or were limited to individual-level change readiness. We focused on identifying the psychometric properties of instruments that were developed to assess readiness in an organization prior to implementing KT interventions in health care. We used the Standards for Educational and Psychological Testing to assess the psychometric properties of identified ORC measurement instruments. Findings We found 26 eligible instruments described in 39 publications. According to the Standards for Educational and Psychological Testing, 18 (69%) of a total of 26 measurement instruments presented both validity and reliability criteria. The Texas Christian University –ORC (TCU-ORC) scale reported the highest instrument validity with a score of 4 out of 4. Only one instrument, namely the Modified Texas Christian University – Director version (TCU-ORC-D), reported a reliability score of 2 out of 3. No information was provided regarding the reliability and validity of five (19%) instruments. Conclusion Our findings indicate that there are few valid and reliable ORC measurement instruments that could be applied to KT in the health care sector. The TCU-ORC instrument presents the best evidence in terms of validity testing. Future studies using this instrument could

  15. Impact of Nuclear Data Uncertainties on Calculated Spent Fuel Nuclide Inventories and Advanced NDA Instrument Response

    DOE PAGES

    Hu, Jianwei; Gauld, Ian C.

    2014-12-01

    The U.S. Department of Energy’s Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) project is nearing the final phase of developing several advanced nondestructive assay (NDA) instruments designed to measure spent nuclear fuel assemblies for the purpose of improving nuclear safeguards. Current efforts are focusing on calibrating several of these instruments with spent fuel assemblies at two international spent fuel facilities. Modelling and simulation is expected to play an important role in predicting nuclide compositions, neutron and gamma source terms, and instrument responses in order to inform the instrument calibration procedures. As part of NGSI-SF project, this work was carried outmore » to assess the impacts of uncertainties in the nuclear data used in the calculations of spent fuel content, radiation emissions and instrument responses. Nuclear data is an essential part of nuclear fuel burnup and decay codes and nuclear transport codes. Such codes are routinely used for analysis of spent fuel and NDA safeguards instruments. Hence, the uncertainties existing in the nuclear data used in these codes affect the accuracies of such analysis. In addition, nuclear data uncertainties represent the limiting (smallest) uncertainties that can be expected from nuclear code predictions, and therefore define the highest attainable accuracy of the NDA instrument. This work studies the impacts of nuclear data uncertainties on calculated spent fuel nuclide inventories and the associated NDA instrument response. Recently developed methods within the SCALE code system are applied in this study. The Californium Interrogation with Prompt Neutron instrument was selected to illustrate the impact of these uncertainties on NDA instrument response.« less

  16. Impact of Nuclear Data Uncertainties on Calculated Spent Fuel Nuclide Inventories and Advanced NDA Instrument Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Jianwei; Gauld, Ian C.

    The U.S. Department of Energy’s Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) project is nearing the final phase of developing several advanced nondestructive assay (NDA) instruments designed to measure spent nuclear fuel assemblies for the purpose of improving nuclear safeguards. Current efforts are focusing on calibrating several of these instruments with spent fuel assemblies at two international spent fuel facilities. Modelling and simulation is expected to play an important role in predicting nuclide compositions, neutron and gamma source terms, and instrument responses in order to inform the instrument calibration procedures. As part of NGSI-SF project, this work was carried outmore » to assess the impacts of uncertainties in the nuclear data used in the calculations of spent fuel content, radiation emissions and instrument responses. Nuclear data is an essential part of nuclear fuel burnup and decay codes and nuclear transport codes. Such codes are routinely used for analysis of spent fuel and NDA safeguards instruments. Hence, the uncertainties existing in the nuclear data used in these codes affect the accuracies of such analysis. In addition, nuclear data uncertainties represent the limiting (smallest) uncertainties that can be expected from nuclear code predictions, and therefore define the highest attainable accuracy of the NDA instrument. This work studies the impacts of nuclear data uncertainties on calculated spent fuel nuclide inventories and the associated NDA instrument response. Recently developed methods within the SCALE code system are applied in this study. The Californium Interrogation with Prompt Neutron instrument was selected to illustrate the impact of these uncertainties on NDA instrument response.« less

  17. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis

    PubMed Central

    John-Baptiste, A.; Sowerby, L.J.; Chin, C.J.; Martin, J.; Rotenberg, B.W.

    2016-01-01

    Background: When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). Methods: We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. Results: The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Interpretation: Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems. PMID:27975045

  18. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    PubMed

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  19. Development and Validation of an Instrument for Assessing Attitudes of High School Students about Recycling

    ERIC Educational Resources Information Center

    Ugulu, Ilker

    2015-01-01

    Recycling and its applications are growing significantly due to the great potential for solving a range of environmental problems in society. Nevertheless, there are currently very few instruments that can provide valid and reliable data on students' attitudes toward recycling. In this regard, this article focuses on the development and validation…

  20. Reuse of disposable laparoscopic instruments: cost analysis*

    PubMed Central

    DesCôteaux, Jean-Gaston; Tye, Lucille; Poulin, Eric C.

    1996-01-01

    Objective To evaluate the cost benefits of reusing disposable laparoscopic instruments. Design A cost-analysis study based on a review of laparoscopic and thoracoscopic procedures performed between August 1990 and January 1994, including analysis of disposable instrument use, purchase records, and reprocessing costs for each instrument. Setting The general surgery department of a 461-bed teaching hospital where disposable laparoscopic instruments are routinely reused according to internally validated reprocessing protocols. Methods Laparoscopic and thoracoscopic interventions performed between August 1990 and January 1994 for which the number and types of disposable laparoscopic instruments were standardized. Main Outcome Measures Reprocessing cost per instrument, the savings realized by reusing disposable laparoscopic instruments and the cost-efficient number of reuses per instrument. Results The cost of reprocessing instruments varied from $2.64 (Can) to $4.66 for each disposable laparoscopic instrument. Purchases of 10 commonly reused disposable laparoscopic instruments totalled $183 279, and the total reprocessing cost was estimated at $35 665 for the study period. Not reusing disposable instruments would have cost $527 575 in instrument purchases for the same period. Disposable laparoscopic instruments were reused 1.7 to 68 times each. Conclusions Under carefully monitored conditions and strict guidelines, reuse of disposable laparoscopic and thoracoscopic instruments can be cost-effective. PMID:8769924

  1. LST and instrument considerations. [modular design

    NASA Technical Reports Server (NTRS)

    Levin, G. M.

    1974-01-01

    In order that the LST meet its scientific objectives and also be a National Astronomical Space Facility during the 1980's and 1990's, broad requirements have been levied by the scientific community. These scientific requirements can be directly translated into design requirements and specifications for the scientific instruments. The instrument ensemble design must be consistent with a 15-year operational lifetime. Downtime for major repair/refurbishment or instrument updating must be minimized. The overall efficiency and performance of the instruments should be maximized. Modularization of instruments and instrument subsystems, some degree of on-orbit servicing (both repair and replacement), on-axis location, minimizing the number of reflections within instruments, minimizing polarization effects, and simultaneous operation of the F/24 camera with other instruments, are just a few of the design guidelines and specifications which can and will be met in order that these broader scientific requirements be satisfied.-

  2. Development of the Quality of Australian Nursing Documentation in Aged Care (QANDAC) instrument to assess paper-based and electronic resident records.

    PubMed

    Wang, Ning; Björvell, Catrin; Hailey, David; Yu, Ping

    2014-12-01

    To develop an Australian nursing documentation in aged care (Quality of Australian Nursing Documentation in Aged Care (QANDAC)) instrument to measure the quality of paper-based and electronic resident records. The instrument was based on the nursing process model and on three attributes of documentation quality identified in a systematic review. The development process involved five phases following approaches to designing criterion-referenced measures. The face and content validities and the inter-rater reliability of the instrument were estimated using a focus group approach and consensus model. The instrument contains 34 questions in three sections: completion of nursing history and assessment, description of care process and meeting the requirements of data entry. Estimates of the validity and inter-rater reliability of the instrument gave satisfactory results. The QANDAC instrument may be a useful audit tool for quality improvement and research in aged care documentation. © 2013 ACOTA.

  3. Advances in Neutron Spectroscopy and High Magnetic Field Instrumentation for studies of Correlated Electron Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granroth, Garrett E

    2011-01-01

    Neutron Spectroscopy has provided critical information on the magnetism in correlated electron systems. Specifically quantum magnets, superconductors, and multi-ferroics are areas of productive research. A discussion of recent measurements on the SEQUOIA spectrometer will provide examples of how novel instrumentation concepts are used on the latest generation of spectrometers to extend our knowledge in such systems. The now ubiquitous function of sample rotation allows for full mapping of volumes ofmore » $Q$ and $$\\omega$$ space. An instrument focused on low angles could extend these maps to cover more of the first Brillioun zone. Innovative chopper cascades allow two unique modes of operation. Multiplexed measurements allow the simultaneous measurement of high and low energy features in an excitation spectrum. Alternatively by limiting the neutron bandwidth incident on the Fermi Chopper, background from subsequent time frames is removed, enabling the observation of weak, large energy transfer features. Finally the implementation of event-based detection for neutron experiments is time correlated experiments. Diffraction studies of the high field spin states in MnWO$$_4$$ using magnetic fields up to 30 T, provided by a pulsed magnet, illustrate this method. Expanding the high field studies to spectroscopy will require a novel instrument, focused around a world class DC magnet, like Zeemans proposed for the SNS.« less

  4. Multimode laser beam analyzer instrument using electrically programmable optics.

    PubMed

    Marraccini, Philip J; Riza, Nabeel A

    2011-12-01

    Presented is a novel design of a multimode laser beam analyzer using a digital micromirror device (DMD) and an electronically controlled variable focus lens (ECVFL) that serve as the digital and analog agile optics, respectively. The proposed analyzer is a broadband laser characterization instrument that uses the agile optics to smartly direct light to the required point photodetectors to enable beam measurements of minimum beam waist size, minimum waist location, divergence, and the beam propagation parameter M(2). Experimental results successfully demonstrate these measurements for a 500 mW multimode test laser beam with a wavelength of 532 nm. The minimum beam waist, divergence, and M(2) experimental results for the test laser are found to be 257.61 μm, 2.103 mrad, 1.600 and 326.67 μm, 2.682 mrad, 2.587 for the vertical and horizontal directions, respectively. These measurements are compared to a traditional scan method and the results of the beam waist are found to be within error tolerance of the demonstrated instrument.

  5. [Stainless steels for medical instruments].

    PubMed

    Feofilov, R N

    1981-01-01

    Both in the USSR and abroad similar types of martensitic and austenitic stainless steel are used for the manufacture of medical instruments. Martensitic steel, the cheapest and most economically alloyed, has the best combination of properties necessary for medical instruments. The analysis of the Soviet and foreign experience in using different grades of steel for the production of medical instruments demonstrates the expediency and possibility of improving the quality of martensitic steel and rolled stock, as well as that of medical instruments manufactured from these materials, by improving, the operations of the metallurgical and technological processes and by specifying more precisely the requirements for medical instruments. The possibility and expediency of using, in some technically justified cases, lower grades of alloyed steel instead of grade 12X18H9T for clamps and other instruments made of stainless steel, as well as highly corrosive grades of steel for microinstruments, have been established.

  6. 14 CFR 121.307 - Engine instruments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine instruments. 121.307 Section 121.307..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.307 Engine instruments. Unless the Administrator allows or requires different instrumentation for turbine engine powered...

  7. 14 CFR 121.307 - Engine instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Engine instruments. 121.307 Section 121.307..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.307 Engine instruments. Unless the Administrator allows or requires different instrumentation for turbine engine powered...

  8. 14 CFR 121.307 - Engine instruments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Engine instruments. 121.307 Section 121.307..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.307 Engine instruments. Unless the Administrator allows or requires different instrumentation for turbine engine powered...

  9. 14 CFR 121.307 - Engine instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Engine instruments. 121.307 Section 121.307..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.307 Engine instruments. Unless the Administrator allows or requires different instrumentation for turbine engine powered...

  10. 14 CFR 121.307 - Engine instruments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Engine instruments. 121.307 Section 121.307..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.307 Engine instruments. Unless the Administrator allows or requires different instrumentation for turbine engine powered...

  11. Hybrid Instrumentation in Lumbar Spinal Fusion: A Biomechanical Evaluation of Three Different Instrumentation Techniques.

    PubMed

    Obid, Peter; Danyali, Reza; Kueny, Rebecca; Huber, Gerd; Reichl, Michael; Richter, Alexander; Niemeyer, Thomas; Morlock, Michael; Püschel, Klaus; Übeyli, Hüseyin

    2017-02-01

    Ex vivo human cadaveric study. The development or progression of adjacent segment disease (ASD) after spine stabilization and fusion is a major problem in spine surgery. Apart from optimal balancing of the sagittal profile, dynamic instrumentation is often suggested to prevent or impede ASD. Hybrid instrumentation is used to gain stabilization while allowing motion to avoid hypermobility in the adjacent segment. In this biomechanical study, the effects of two different hybrid instrumentations on human cadaver spines were evaluated and compared with a rigid instrumentation. Eighteen human cadaver spines (T11-L5) were subdivided into three groups: rigid, dynamic, and hook comprising six spines each. Clinical parameters and initial mechanical characteristics were consistent among groups. All specimens received rigid fixation from L3-L5 followed by application of a free bending load of extension and flexion. The range of motion (ROM) for every segment was evaluated. For the rigid group, further rigid fixation from L1-L5 was applied. A dynamic Elaspine system (Spinelab AG, Winterthur, Switzerland) was applied from L1 to L3 for the dynamic group, and the hook group was instrumented with additional laminar hooks at L1-L3. ROM was then evaluated again. There was no significant difference in ROM among the three instrumentation techniques. Based on this data, the intended advantage of a hybrid or dynamic instrumentation might not be achieved.

  12. Effects of Internal and External Focus of Attention during Novices' Instructional Preparation on Subsequent Rehearsal Behaviors

    ERIC Educational Resources Information Center

    Montemayor, Mark; Silvey, Brian A.; Adams, Amy L.; Witt, Kay L.

    2016-01-01

    The purpose of this study was to investigate the effects of internal versus external focus of attention during novice teachers' instructional preparation on their subsequent rehearsal behaviors. Thirty-two undergraduate instrumental music education students led bands in a series of three, 6-minute rehearsals on their assigned excerpt. Prior to…

  13. Eight year experience in open ended instrumentation laboratory

    NASA Astrophysics Data System (ADS)

    Marques, Manuel B.; Rosa, Carla C.; Marques, Paulo V. S.

    2015-10-01

    When designing laboratory courses in a Physics Major we consider a range of objectives: teaching Physics; developing lab competencies; instrument control and data acquisition; learning about measurement errors and error propagation; an introduction to project management; team work skills and scientific writing. But nowadays we face pressure to decrease laboratory hours due to the cost involved. Many universities are replacing lab classes for simulation activities, hiring PhD. and master students to give first year lab classes, and reducing lab hours. This leads to formatted lab scripts and poor autonomy of the students, and failure to enhance creativity and autonomy. In this paper we present our eight year experience with a laboratory course that is mandatory in the third year of Physics and Physical Engineering degrees. Since the students had previously two standard laboratory courses, we focused on teaching instrumentation and giving students autonomy. The course is divided in two parts: one third is dedicated to learn computer controlled instrumentation and data acquisition (based in LabView); the final 2/3 is dedicated to a group project. In this project, the team (2 or 3 students) must develop a project and present it in a typical conference format at the end of the semester. The project assignments are usually not very detailed (about two or three lines long), giving only general guidelines pointing to a successful project (students often recycle objectives putting forward a very personal project); all of them require assembling some hardware. Due to our background, about one third of the projects are related to Optics.

  14. Proposal of optical farming: development of several optical sensing instruments for agricultural use

    NASA Astrophysics Data System (ADS)

    Saito, Y.; Kobayashi, K.

    2013-05-01

    We propose the use of "Optical Farming," which is the leading application of all types of optical technologies, in agriculture and agriculture-related industries. This paper focuses on the optical sensing instruments named "Agriserver," "Agrigadget" and "LIFS Monitor" developed in our laboratory. They are considered major factors in utilizing Optical Farming. Agriserver is a sensor network system that uses the Internet to collect information on agricultural products growing in fields. Agrigadget contains several optical devices, such as a smartphone-based spectroscopic device and a hand framing camera. LIFS Monitor is an advanced monitoring instrument that makes it possible to obtain physiological information of living plants. They are strongly associated with information communication technology. Their field and data usage performance in agricultural industries are reported.

  15. A Multidimensional Scaling Approach to Dimensionality Assessment for Measurement Instruments Modeled by Multidimensional Item Response Theory

    ERIC Educational Resources Information Center

    Toro, Maritsa

    2011-01-01

    The statistical assessment of dimensionality provides evidence of the underlying constructs measured by a survey or test instrument. This study focuses on educational measurement, specifically tests comprised of items described as multidimensional. That is, items that require examinee proficiency in multiple content areas and/or multiple cognitive…

  16. 14 CFR 25.1381 - Instrument lights.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Instrument lights. 25.1381 Section 25.1381... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1381 Instrument lights. (a) The instrument lights must— (1) Provide sufficient illumination to make each instrument, switch and other device...

  17. 14 CFR 25.1381 - Instrument lights.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Instrument lights. 25.1381 Section 25.1381... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1381 Instrument lights. (a) The instrument lights must— (1) Provide sufficient illumination to make each instrument, switch and other device...

  18. 14 CFR 25.1381 - Instrument lights.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Instrument lights. 25.1381 Section 25.1381... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1381 Instrument lights. (a) The instrument lights must— (1) Provide sufficient illumination to make each instrument, switch and other device...

  19. 14 CFR 25.1381 - Instrument lights.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Instrument lights. 25.1381 Section 25.1381... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1381 Instrument lights. (a) The instrument lights must— (1) Provide sufficient illumination to make each instrument, switch and other device...

  20. 14 CFR 25.1381 - Instrument lights.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Instrument lights. 25.1381 Section 25.1381... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1381 Instrument lights. (a) The instrument lights must— (1) Provide sufficient illumination to make each instrument, switch and other device...

  1. Infrared Instrument for Detecting Hydrogen Fires

    NASA Technical Reports Server (NTRS)

    Youngquist, Robert; Ihlefeld, Curtis; Immer, Christopher; Oostdyk, Rebecca; Cox, Robert; Taylor, John

    2006-01-01

    The figure shows an instrument incorporating an infrared camera for detecting small hydrogen fires. The instrument has been developed as an improved replacement for prior infrared and ultraviolet instruments used to detect hydrogen fires. The need for this or any such instrument arises because hydrogen fires (e.g., those associated with leaks from tanks, valves, and ducts) pose a great danger, yet they emit so little visible light that they are mostly undetectable by the unaided human eye. The main performance advantage offered by the present instrument over prior hydrogen-fire-detecting instruments lies in its greater ability to avoid false alarms by discriminating against reflected infrared light, including that originating in (1) the Sun, (2) welding torches, and (3) deliberately ignited hydrogen flames (e.g., ullage-burn-off flames) that are nearby but outside the field of view intended to be monitored by the instrument. Like prior such instruments, this instrument is based mostly on the principle of detecting infrared emission above a threshold level. However, in addition, this instrument utilizes information on the spatial distribution of infrared light from a source that it detects. Because the combination of spatial and threshold information about a flame tends to constitute a unique signature that differs from that of reflected infrared light originating in a source not in the field of view, the incidence of false alarms is reduced substantially below that of related prior threshold- based instruments.

  2. 14 CFR 23.1381 - Instrument lights.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...

  3. 14 CFR 23.1381 - Instrument lights.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...

  4. 14 CFR 23.1381 - Instrument lights.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...

  5. 14 CFR 23.1381 - Instrument lights.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...

  6. 14 CFR 23.1381 - Instrument lights.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...

  7. Developing a workplace resilience instrument.

    PubMed

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  8. Development of an instrument for assessing workstyle in checkout cashier work (BAsIK).

    PubMed

    Kjellberg, Katarina; Palm, Peter; Josephson, Malin

    2012-01-01

    Checkout cashier work consists of handling a large number of items during a work shift, which implies repetitive movements of the shoulders, arms and hands/wrists, and a high work rate. The work is associated with a high prevalence of disorders in the neck and upper extremity. The concept of workstyle explains how ergonomic and psychosocial factors interact in the development of work-related upper extremity disorders. The aim of the project was to develop an instrument for the occupational health services to be used in the efforts to prevent upper extremity disorders in checkout cashier work. The instrument is based on the workstyle concept and is intended to be used as a tool to identify high-risk workstyle and needs for interventions, such as training and education. The instrument, BAsIK, consists of four parts; a questionnaire about workstyle, an observation protocol for work technique, a checklist about the design of the checkout and a questionnaire about work organization. The instrument was developed by selecting workstyle items developed for office work and adapting them to checkout cashier work, discussions with researchers and ergonomists, focus-group interviews with cashiers, observations of video recordings of cashiers, and studies of existing guidelines and checklists.

  9. Instrument Adaptation in Cross-Cultural Studies of Students' Mathematics-Related Beliefs: Learning from Healthcare Research

    ERIC Educational Resources Information Center

    Andrews, Paul; Diego-Mantecón, Jose

    2015-01-01

    Much comparative research into education-related beliefs has exploited questionnaires developed in one culture for use in another. This has been particularly the case in mathematics education, the focus of this paper. In so doing, researchers have tended to assume that translation alone is sufficient to warrant a reliable and valid instrument for…

  10. High-intensity-focused-ultrasound (HIFU) induced homeostasis and tissue ablation

    NASA Astrophysics Data System (ADS)

    Chauhan, Sunita; Michel, M. S.; Alken, Peter; Kohrmann, K. U.; Haecker, Axel

    2003-06-01

    At high intensity levels, ultrasound energy focused into remote tissue targets in human body has shown to produce thermal necrosis in circumscribed regions with sub-millimeter accuracy. The non-invasive modality known as HIFU has enormous potential for thermal ablation of cancers/tumors of the human body without any adverse effects in the surrounding normal tissue. In this paper, empirical results for parametric assessment and interdependence of several exposure variables are presented for producing thermal necrosis as well as hemostasis. Multiple HIFU transducers in selective spatial configuration have been deployed using a suitably designed experiemntal harness, with and without motorized jig scanning. The pre-planning and on-line procedure for treatment and specified instrumentation is described. Custom designed 25mm aperture HIFU probes resonating at 2 MHz focused at 64 and 80 mm are used. Results have been obtained in ex-vivo animal tissue and in vitro biological phantoms for hemostasis.

  11. A multi-topographical-instrument analysis: the breast implant texture measurement

    NASA Astrophysics Data System (ADS)

    Garabédian, Charles; Delille, Rémi; Deltombe, Raphaël; Anselme, Karine; Atlan, Michael; Bigerelle, Maxence

    2017-06-01

    Capsular contracture is a major complication after implant-based breast augmentation. To address this tissue reaction, most manufacturers texture the outer breast implant surfaces with calibrated salt grains. However, the analysis of these surfaces on sub-micron scales has been under-studied. This scale range is of interest to understand the future of silicone particles potentially released from the implant surface and the aetiology of newly reported complications, such as Anaplastic Large Cell Lymphoma. The surface measurements were accomplished by tomography and by two optical devices based on interferometry and on focus variation. The robustness of the measurements was investigated from the tissue scale to the cellular scale. The macroscopic pore-based structure of the textured implant surfaces is consistently measured by the three instruments. However, the multi-scale analyses start to be discrepant in a scale range between 50 µm and 500 µm characteristic of a finer secondary roughness regardless of the pore shape. The focus variation and the micro-tomography would fail to capture this roughness regime because of a focus-related optical artefact and of step-shaped artefact respectively.

  12. Development of an Instrument for Evaluating Anxiety Caused by Cognitive Conflict

    NASA Astrophysics Data System (ADS)

    Kim, Yeounsoo; Bao, Lei

    2005-09-01

    Physics learning situations often involve many cognitive conflicts between a student's present understandings and new information being learned. Cognitive conflict is known as an important factor in conceptual change. Therefore, it is important to help physics teachers and students develop skills and knowledge for more effective conflict management. However there is no readily available method to monitor the existence and features of cognitive conflicts that students may encounter during their learning. We focus the study on student anxiety caused by cognitive conflict so that we can improve student motivation. This study is targeted to develop an easy-to-use instrument that can be implemented in the classrooms to monitor student anxiety in cognitive conflict situations and the effects on student motivation. In this paper, we will discuss the structure of this instrument and show results from using this tool in our Physics by Inquiry class.

  13. On-Orbit Performance of the Helioseismic and Magnetic Imager Instrument onboard the Solar Dynamics Observatory

    NASA Astrophysics Data System (ADS)

    Hoeksema, J. T.; Baldner, C. S.; Bush, R. I.; Schou, J.; Scherrer, P. H.

    2018-03-01

    The Helioseismic and Magnetic Imager (HMI) instrument is a major component of NASA's Solar Dynamics Observatory (SDO) spacecraft. Since commencement of full regular science operations on 1 May 2010, HMI has operated with remarkable continuity, e.g. during the more than five years of the SDO prime mission that ended 30 September 2015, HMI collected 98.4% of all possible 45-second velocity maps; minimizing gaps in these full-disk Dopplergrams is crucial for helioseismology. HMI velocity, intensity, and magnetic-field measurements are used in numerous investigations, so understanding the quality of the data is important. This article describes the calibration measurements used to track the performance of the HMI instrument, and it details trends in important instrument parameters during the prime mission. Regular calibration sequences provide information used to improve and update the calibration of HMI data. The set-point temperature of the instrument front window and optical bench is adjusted regularly to maintain instrument focus, and changes in the temperature-control scheme have been made to improve stability in the observable quantities. The exposure time has been changed to compensate for a 20% decrease in instrument throughput. Measurements of the performance of the shutter and tuning mechanisms show that they are aging as expected and continue to perform according to specification. Parameters of the tunable optical-filter elements are regularly adjusted to account for drifts in the central wavelength. Frequent measurements of changing CCD-camera characteristics, such as gain and flat field, are used to calibrate the observations. Infrequent expected events such as eclipses, transits, and spacecraft off-points interrupt regular instrument operations and provide the opportunity to perform additional calibration. Onboard instrument anomalies are rare and seem to occur quite uniformly in time. The instrument continues to perform very well.

  14. Spacecraft instrument calibration and stability

    NASA Technical Reports Server (NTRS)

    Gille, J. C.; Feldman, P.; Hudson, R.; Lean, J.; Madden, R.; Mcmaster, L.; Mount, G.; Rottman, G.; Simon, P. C.

    1989-01-01

    The following topics are covered: instrument degradation; the Solar Backscatter Ultraviolet (SBUV) Experiment; the Total Ozone Mapping Spectrometer (TOMS); the Stratospheric Aerosol and Gas Experiment 1 (SAGE-1) and SAGE-2 instruments; the Solar Mesosphere Explorer (SME) UV ozone and near infrared airglow instruments; and the Limb Infrared Monitor of the Stratosphere (LIMS).

  15. Advanced optical instruments technology

    NASA Technical Reports Server (NTRS)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-01-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  16. Advanced optical instruments technology

    NASA Astrophysics Data System (ADS)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  17. Measuring pediatric hematology-oncology fellows' skills in humanism and professionalism: A novel assessment instrument.

    PubMed

    Kesselheim, Jennifer C; Agrawal, Anurag K; Bhatia, Nita; Cronin, Angel; Jubran, Rima; Kent, Paul; Kersun, Leslie; Rao, Amulya Nageswara; Rose, Melissa; Savelli, Stephanie; Sharma, Mukta; Shereck, Evan; Twist, Clare J; Wang, Michael

    2017-05-01

    Educators in pediatric hematology-oncology lack rigorously developed instruments to assess fellows' skills in humanism and professionalism. We developed a novel 15-item self-assessment instrument to address this gap in fellowship training. Fellows (N = 122) were asked to assess their skills in five domains: balancing competing demands of fellowship, caring for the dying patient, confronting depression and burnout, responding to challenging relationships with patients, and practicing humanistic medicine. An expert focus group predefined threshold scores on the instrument that could be used as a cutoff to identify fellows who need support. Reliability and feasibility were assessed and concurrent validity was measured using three established instruments: Maslach Burnout Inventory (MBI), Flourishing Scale (FS), and Jefferson Scale of Physician Empathy (JSPE). For 90 participating fellows (74%), the self-assessment proved feasible to administer and had high internal consistency reliability (Cronbach's α = 0.81). It was moderately correlated with the FS and MBI (Pearson's r = 0.41 and 0.4, respectively) and weakly correlated with the JSPE (Pearson's r = 0.15). Twenty-eight fellows (31%) were identified as needing support. The self-assessment had a sensitivity of 50% (95% confidence interval [CI]: 31-69) and a specificity of 77% (95% CI: 65-87) for identifying fellows who scored poorly on at least one of the three established scales. We developed a novel assessment instrument for use in pediatric fellowship training. The new scale proved feasible and demonstrated internal consistency reliability. Its moderate correlation with other established instruments shows that the novel assessment instrument provides unique, nonredundant information as compared to existing scales. © 2016 Wiley Periodicals, Inc.

  18. Hyperkahler metrics on focus-focus fibrations

    NASA Astrophysics Data System (ADS)

    Zhao, Jie

    In this thesis, we focus on the study of hyperkahler metric in four dimensional cases, and practice GMN's construction of hyperkahler metric on focus-focus fibrations. We explicitly compute the action-angle coordinates on the local model of focus-focus fibration, and show its semi-global invariant should be harmonic to admit a compatible holomorphic 2-form. Then we study the canonical semi-flat metric on it. After the instanton correction inspired by physics, we get a family of the generalized Ooguri-Vafa metric on focus-focus fibrations, which becomes more local examples of explicit hyperkahler metric in four dimensional cases. In addition, we also make some exploration of the Ooguri-Vafa metric in the thesis. We study the potential function of the Ooguri-Vafa metric, and prove that its nodal set is a cylinder of bounded radius 1 < R < 1. As a result, we get that only on a finite neighborhood of the singular fibre the Ooguri-Vafa metric is a hyperkahler metric. Finally, we give some estimates for the diameter of the fibration under the Oogui-Vafa metric, which confirms that the Oogui-Vafa metric is not complete. The new family of metric constructed in the thesis, we think, will provide more examples to further study of Lagrangian fibrations and mirror symmetry in future.

  19. Cardiovascular instrumentation for spaceflight

    NASA Technical Reports Server (NTRS)

    Schappell, R. T.; Polhemus, J. T.; Ganiaris, N. J.

    1976-01-01

    The observation mechanisms dealing with pressure, flow, morphology, temperature, etc. are discussed. The approach taken in the performance of this study was to (1) review ground and space-flight data on cardiovascular function, including earlier related ground-based and space-flight animal studies, Mercury, Gemini, Apollo, Skylab, and recent bed-rest studies, (2) review cardiovascular measurement parameters required to assess individual performance and physiological alternations during space flight, (3) perform an instrumentation survey including a literature search as well as personal contact with the applicable investigators, (4) assess instrumentation applicability with respect to the established criteria, and (5) recommend future research and development activity. It is concluded that, for the most part, the required instrumentation technology is available but that mission-peculiar criteria will require modifications to adapt the applicable instrumentation to a space-flight configuration.

  20. The Focusing Optics X-ray Solar Imager (FOXSI) SMEX Mission

    NASA Astrophysics Data System (ADS)

    Christe, S.; Shih, A. Y.; Krucker, S.; Glesener, L.; Saint-Hilaire, P.; Caspi, A.; Allred, J. C.; Battaglia, M.; Chen, B.; Drake, J. F.; Gary, D. E.; Goetz, K.; Gburek, S.; Grefenstette, B.; Hannah, I. G.; Holman, G.; Hudson, H. S.; Inglis, A. R.; Ireland, J.; Ishikawa, S. N.; Klimchuk, J. A.; Kontar, E.; Kowalski, A. F.; Massone, A. M.; Piana, M.; Ramsey, B.; Schwartz, R.; Steslicki, M.; Turin, P.; Ryan, D.; Warmuth, A.; Veronig, A.; Vilmer, N.; White, S. M.; Woods, T. N.

    2017-12-01

    We present FOXSI (Focusing Optics X-ray Solar Imager), a Small Explorer (SMEX) Heliophysics mission that is currently undergoing a Phase A concept study. FOXSI will provide a revolutionary new perspective on energy release and particle acceleration on the Sun. FOXSI is a direct imaging X-ray spectrometer with higher dynamic range and better than 10x the sensitivity of previous instruments. Flown on a 3-axis-stabilized spacecraft in low-Earth orbit, FOXSI uses high-angular-resolution grazing-incidence focusing optics combined with state-of-the-art pixelated solid-state detectors to provide direct imaging of solar hard X-rays for the first time. FOXSI is composed of a pair of x-ray telescopes with a 14-meter focal length enabled by a deployable boom. Making use of a filter-wheel and high-rate-capable solid-state detectors, FOXSI will be able to observe the largest flares without saturation while still maintaining the sensitivity to detect x-ray emission from weak flares, escaping electrons, and hot active regions. This mission concept is made possible by past experience with similar instruments on two FOXSI sounding rocket flights, in 2012 and 2014, and on the HEROES balloon flight in 2013. FOXSI's hard X-ray imager has a field of view of 9 arcminutes and an angular resolution of better than 8 arcsec; it will cover the energy range from 3 up to 50-70 keV with a spectral resolution of better than 1 keV; and it will have sub-second temporal resolution.

  1. Instrument Attitude Precision Control

    NASA Technical Reports Server (NTRS)

    Juang, Jer-Nan

    2004-01-01

    A novel approach is presented in this paper to analyze attitude precision and control for an instrument gimbaled to a spacecraft subject to an internal disturbance caused by a moving component inside the instrument. Nonlinear differential equations of motion for some sample cases are derived and solved analytically to gain insight into the influence of the disturbance on the attitude pointing error. A simple control law is developed to eliminate the instrument pointing error caused by the internal disturbance. Several cases are presented to demonstrate and verify the concept presented in this paper.

  2. Animation of MARDI Instrument

    NASA Image and Video Library

    2008-09-30

    This frame from an animation shows a zoom into the Mars Descent Imager MARDI instrument onboard NASA Phoenix Mars Lander. The Phoenix team will soon attempt to use a microphone on the MARDI instrument to capture sounds of Mars.

  3. The Keck Cosmic Web Imager (KCWI): A Powerful New Integral Field Spectrograph for the Keck Observatory

    NASA Astrophysics Data System (ADS)

    Morrissey, Patrick; KCWI Team

    2013-01-01

    The Keck Cosmic Web Imager (KCWI) is a new facility instrument being developed for the W. M. Keck Observatory and funded for construction by the Telescope System Instrumentation Program (TSIP) of the National Science Foundation (NSF). KCWI is a bench-mounted spectrograph for the Keck II right Nasmyth focal station, providing integral field spectroscopy over a seeing-limited field up to 20"x33" in extent. Selectable Volume Phase Holographic (VPH) gratings provide high efficiency and spectral resolution in the range of 1000 to 20000. The dual-beam design of KCWI passed a Preliminary Design Review in summer 2011. The detailed design of the KCWI blue channel (350 to 700 nm) is now nearly complete, with the red channel (530 to 1050 nm) planned for a phased implementation contingent upon additional funding. KCWI builds on the experience of the Caltech team in implementing the Cosmic Web Imager (CWI), in operation since 2009 at Palomar Observatory. KCWI adds considerable flexibility to the CWI design, and will take full advantage of the excellent seeing and dark sky above Mauna Kea with a selectable nod-and-shuffle observing mode. The KCWI team is lead by Caltech (project management, design and implementation) in partnership with the University of California at Santa Cruz (camera optical and mechanical design) and the W. M. Keck Observatory (program oversight and observatory interfaces).

  4. Risk factors for supplementary posterior instrumentation after anterolateral decompression and instrumentation in thoracolumbar burst fractures.

    PubMed

    Hitchon, Patrick W; He, Wenzhuan; Dahdaleh, Nader S; Moritani, Toshio

    2014-11-01

    In spite of the established benefits of anterolateral decompression and instrumentation (ALDI) for thoracolumbar burst fractures (TLBF), the indications for supplementary posterior instrumentation remain unclear. A retrospective review of clinical and radiographic data of a prospective cohort of 73 patients who underwent ALDI for TLBF from T12 to L4. The mean age of the cohort was 42 ± 15 years, with 49 males and 24 females. Forty-six patients had neurological deficit, and 27 were intact. Owing to symptomatic settling, supplemental posterior instrumentation was performed in 7 out of 73 patients. The age of patients requiring supplemental posterior instrumentation (59 ± 14 years) exceeded that of patients who did not (41 ± 16, p=0.004). Otherwise, the patients who required posterior instrumentation were comparable to those treated with ALDI in terms of body mass index (BMI), American Spinal Injury Association (ASIA) scores on admission and follow-up, residual spinal canal, and local kyphosis on admission and follow-up. The posterior ligamentous complex (PLC) integrity was assessed in 38 patients in whom the MRI scans were retrievable, 31 successfully treated with ALDI, and all 7 undergoing supplementary posterior instrumentation. Subgroup analysis demonstrated that there was no difference in the incidence of PLC disruption between the 2 groups (p=0.257). Secondary supplemental posterior instrumentation was deemed necessary in 10% of cases following ALDI. Age was the only significant risk factor predicating supplemental posterior instrumentation. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Advanced sampling techniques for hand-held FT-IR instrumentation

    NASA Astrophysics Data System (ADS)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  6. Developing Evidence for Action on the Postgraduate Experience: An Effective Local Instrument to Move beyond Benchmarking

    ERIC Educational Resources Information Center

    Sampson, K. A.; Johnston, L.; Comer, K.; Brogt, E.

    2016-01-01

    Summative and benchmarking surveys to measure the postgraduate student research experience are well reported in the literature. While useful, we argue that local instruments that provide formative resources with an academic development focus are also required. If higher education institutions are to move beyond the identification of issues and…

  7. Antitheft container for instruments

    NASA Technical Reports Server (NTRS)

    Kerley, J. J., Jr.

    1979-01-01

    Antitheft container is used to prevent theft of calculators, portable computers, and other small instruments. Container design is simple and flexible enough to allow easy access to display or input systems of instruments, while not interfering with power input to device.

  8. 21 CFR 882.4525 - Microsurgical instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4525 Microsurgical instrument. (a) Identification. A microsurgical instrument is a nonpowered surgical instrument used in neurological microsurgery...

  9. 21 CFR 882.4525 - Microsurgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4525 Microsurgical instrument. (a) Identification. A microsurgical instrument is a nonpowered surgical instrument used in neurological microsurgery...

  10. Instrumentation-related uncertainty of reflectance and transmittance measurements with a two-channel spectrophotometer.

    PubMed

    Peest, Christian; Schinke, Carsten; Brendel, Rolf; Schmidt, Jan; Bothe, Karsten

    2017-01-01

    Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.

  11. Development and psychometric testing of an instrument to measure safety climate perceptions in community pharmacy.

    PubMed

    Newham, Rosemary; Bennie, Marion; Maxwell, David; Watson, Anne; de Wet, Carl; Bowie, Paul

    2014-12-01

    A positive and strong safety culture underpins effective learning from patient safety incidents in health care, including the community pharmacy (CP) setting. To build this culture, perceptions of safety climate must be measured with context-specific and reliable instruments. No pre-existing instruments were specifically designed or suitable for CP within Scotland. We therefore aimed to develop a psychometrically sound instrument to measure perceptions of safety climate within Scottish CPs. The first stage, development of a preliminary instrument, comprised three steps: (i) a literature review; (ii) focus group feedback; and (iii) content validation. The second stage, psychometric testing, consisted of three further steps: (iv) a pilot survey; (v) a survey of all CP staff within a single health board in NHS Scotland; and (vi) application of statistical methods, including principal components analysis and calculation of Cronbach's reliability coefficients, to derive the final instrument. The preliminary questionnaire was developed through a process of literature review and feedback. This questionnaire was completed by staff in 50 CPs from the 131 (38%) sampled. 250 completed questionnaires were suitable for analysis. Psychometric evaluation resulted in a 30-item instrument with five positively correlated safety climate factors: leadership, teamwork, safety systems, communication and working conditions. Reliability coefficients were satisfactory for the safety climate factors (α > 0.7) and overall (α = 0.93). The robust nature of the technical design and testing process has resulted in the development of an instrument with sufficient psychometric properties, which can be implemented in the community pharmacy setting in NHS Scotland. © 2014 John Wiley & Sons, Ltd.

  12. Generic health literacy measurement instruments for children and adolescents: a systematic review of the literature.

    PubMed

    Okan, Orkan; Lopes, Ester; Bollweg, Torsten Michael; Bröder, Janine; Messer, Melanie; Bruland, Dirk; Bond, Emma; Carvalho, Graça S; Sørensen, Kristine; Saboga-Nunes, Luis; Levin-Zamir, Diane; Sahrai, Diana; Bittlingmayer, Uwe H; Pelikan, Jürgen M; Thomas, Malcolm; Bauer, Ullrich; Pinheiro, Paulo

    2018-01-22

    Health literacy is an important health promotion concern and recently children and adolescents have been the focus of increased academic attention. To assess the health literacy of this population, researchers have been focussing on developing instruments to measure their health literacy. Compared to the wider availability of instruments for adults, only a few tools are known for younger age groups. The objective of this study is to systematically review the field of generic child and adolescent health literacy measurement instruments that are currently available. A systematic literature search was undertaken in five databases (PubMed, CINAHL, PsycNET, ERIC, and FIS) on articles published between January 1990 and July 2015, addressing children and adolescents ≤18 years old. Eligible articles were analysed, data was extracted, and synthesised according to review objectives. Fifteen generic health literacy measurement instruments for children and adolescents were identified. All, except two, are self-administered instruments. Seven are objective measures (performance-based tests), seven are subjective measures (self-reporting), and one uses a mixed-method measurement. Most instruments applied a broad and multidimensional understanding of health literacy. The instruments were developed in eight different countries, with most tools originating in the United States (n = 6). Among the instruments, 31 different components related to health literacy were identified. Accordingly, the studies exhibit a variety of implicit or explicit conceptual and operational definitions, and most instruments have been used in schools and other educational contexts. While the youngest age group studied was 7-year-old children within a parent-child study, there is only one instrument specifically designed for primary school children and none for early years. Despite the reported paucity of health literacy research involving children and adolescents, an unexpected number of health

  13. The Society for Implementation Research Collaboration Instrument Review Project: a methodology to promote rigorous evaluation.

    PubMed

    Lewis, Cara C; Stanick, Cameo F; Martinez, Ruben G; Weiner, Bryan J; Kim, Mimi; Barwick, Melanie; Comtois, Katherine A

    2015-01-08

    Identification of psychometrically strong instruments for the field of implementation science is a high priority underscored in a recent National Institutes of Health working meeting (October 2013). Existing instrument reviews are limited in scope, methods, and findings. The Society for Implementation Research Collaboration Instrument Review Project's objectives address these limitations by identifying and applying a unique methodology to conduct a systematic and comprehensive review of quantitative instruments assessing constructs delineated in two of the field's most widely used frameworks, adopt a systematic search process (using standard search strings), and engage an international team of experts to assess the full range of psychometric criteria (reliability, construct and criterion validity). Although this work focuses on implementation of psychosocial interventions in mental health and health-care settings, the methodology and results will likely be useful across a broad spectrum of settings. This effort has culminated in a centralized online open-access repository of instruments depicting graphical head-to-head comparisons of their psychometric properties. This article describes the methodology and preliminary outcomes. The seven stages of the review, synthesis, and evaluation methodology include (1) setting the scope for the review, (2) identifying frameworks to organize and complete the review, (3) generating a search protocol for the literature review of constructs, (4) literature review of specific instruments, (5) development of an evidence-based assessment rating criteria, (6) data extraction and rating instrument quality by a task force of implementation experts to inform knowledge synthesis, and (7) the creation of a website repository. To date, this multi-faceted and collaborative search and synthesis methodology has identified over 420 instruments related to 34 constructs (total 48 including subconstructs) that are relevant to implementation

  14. Sample Analysis at Mars Instrument Simulator

    NASA Technical Reports Server (NTRS)

    Benna, Mehdi; Nolan, Tom

    2013-01-01

    The Sample Analysis at Mars Instrument Simulator (SAMSIM) is a numerical model dedicated to plan and validate operations of the Sample Analysis at Mars (SAM) instrument on the surface of Mars. The SAM instrument suite, currently operating on the Mars Science Laboratory (MSL), is an analytical laboratory designed to investigate the chemical and isotopic composition of the atmosphere and volatiles extracted from solid samples. SAMSIM was developed using Matlab and Simulink libraries of MathWorks Inc. to provide MSL mission planners with accurate predictions of the instrument electrical, thermal, mechanical, and fluid responses to scripted commands. This tool is a first example of a multi-purpose, full-scale numerical modeling of a flight instrument with the purpose of supplementing or even eliminating entirely the need for a hardware engineer model during instrument development and operation. SAMSIM simulates the complex interactions that occur between the instrument Command and Data Handling unit (C&DH) and all subsystems during the execution of experiment sequences. A typical SAM experiment takes many hours to complete and involves hundreds of components. During the simulation, the electrical, mechanical, thermal, and gas dynamics states of each hardware component are accurately modeled and propagated within the simulation environment at faster than real time. This allows the simulation, in just a few minutes, of experiment sequences that takes many hours to execute on the real instrument. The SAMSIM model is divided into five distinct but interacting modules: software, mechanical, thermal, gas flow, and electrical modules. The software module simulates the instrument C&DH by executing a customized version of the instrument flight software in a Matlab environment. The inputs and outputs to this synthetic C&DH are mapped to virtual sensors and command lines that mimic in their structure and connectivity the layout of the instrument harnesses. This module executes

  15. The instrumental rationality of addiction.

    PubMed

    Pickard, Hanna

    2011-12-01

    The claim that non-addictive drug use is instrumental must be distinguished from the claim that its desired ends are evolutionarily adaptive or easy to comprehend. Use can be instrumental without being adaptive or comprehensible. This clarification, together with additional data, suggests that Müller & Schumann's (M&S's) instrumental framework may explain addictive, as well as non-addictive consumption.

  16. Assessing microscope image focus quality with deep learning.

    PubMed

    Yang, Samuel J; Berndl, Marc; Michael Ando, D; Barch, Mariya; Narayanaswamy, Arunachalam; Christiansen, Eric; Hoyer, Stephan; Roat, Chris; Hung, Jane; Rueden, Curtis T; Shankar, Asim; Finkbeiner, Steven; Nelson, Philip

    2018-03-15

    Large image datasets acquired on automated microscopes typically have some fraction of low quality, out-of-focus images, despite the use of hardware autofocus systems. Identification of these images using automated image analysis with high accuracy is important for obtaining a clean, unbiased image dataset. Complicating this task is the fact that image focus quality is only well-defined in foreground regions of images, and as a result, most previous approaches only enable a computation of the relative difference in quality between two or more images, rather than an absolute measure of quality. We present a deep neural network model capable of predicting an absolute measure of image focus on a single image in isolation, without any user-specified parameters. The model operates at the image-patch level, and also outputs a measure of prediction certainty, enabling interpretable predictions. The model was trained on only 384 in-focus Hoechst (nuclei) stain images of U2OS cells, which were synthetically defocused to one of 11 absolute defocus levels during training. The trained model can generalize on previously unseen real Hoechst stain images, identifying the absolute image focus to within one defocus level (approximately 3 pixel blur diameter difference) with 95% accuracy. On a simpler binary in/out-of-focus classification task, the trained model outperforms previous approaches on both Hoechst and Phalloidin (actin) stain images (F-scores of 0.89 and 0.86, respectively over 0.84 and 0.83), despite only having been presented Hoechst stain images during training. Lastly, we observe qualitatively that the model generalizes to two additional stains, Hoechst and Tubulin, of an unseen cell type (Human MCF-7) acquired on a different instrument. Our deep neural network enables classification of out-of-focus microscope images with both higher accuracy and greater precision than previous approaches via interpretable patch-level focus and certainty predictions. The use of

  17. A Scanning Hartmann Focus Test for the EUVI Telescopes aboard STEREO

    NASA Technical Reports Server (NTRS)

    Ohl, R.; Antonille, S.; Aronstein, D.; Dean, B.; Delmont, M.; Eichord, W.; Frey, B.; Kubalak, D.; Wilson, M.; Redman, K.; hide

    2007-01-01

    The Solar TErrestrial RElations Observatory (STEREO), the third mission in NASA s Solar Terrestrial Probes program, was launched in 2006 on a two year mission to study solar phenomena like coronal mass ejections. STEREO consists of two nearly identical satellites, each carrying a suite of instruments that provide, among other data, simultaneous images of the Sun. One of these telescopes is the Extreme Ultraviolet Instrument (EUVI). There are two EUVI telescopes, one on each STEREO satellite (EUVI-A and EUVI-B). EUVI is a normal incidence, 98mm diameter, Ritchey-Chretien telescope designed to obtain wide field of view (approx.1deg) images of the Sun at short wavelengths (approx.20nm) using a CCD detector. The telescope entrance aperture is divided into four quadrants by a mask near the secondary mirror spider veins. A mechanism that rotates another mask allows only one of these sub-apertures to accept light from the Sun during an observation. The EUVI is thus four co-aligned, off-axis telescopes. Each off-axis segment on the primary and secondary mirrors has a different extreme ultraviolet coating stack. Furthermore, the aperture select mechanism is synchronized with a filter wheel mechanism near the CCD detector. The EUVI contains no focus mechanism. Models predict that the difference in on-orbit operating temperature and ambient clean room conditions yield a "best focus" difference between integration and operation of approx. 0.2mm.

  18. Missing content from health-related quality of life instruments: interviews with young adult survivors of childhood cancer.

    PubMed

    Quinn, Gwendolyn P; Huang, I-Chan; Murphy, Devin; Zidonik-Eddelton, Katie; Krull, Kevin R

    2013-02-01

    Young adult survivors of childhood cancer (YASCC) are an ever-growing cohort of survivors due to increasing advances in technology. Today, there is a shift of focus to not just ensuring survivorship but also the quality of survivorship, which can be assessed with standardized instruments. The majority of standardized health related quality of life (HRQoL) instruments, however, are non-specific to this age group and the unique late effects within YASCC populations. The purpose of this study was to investigate the relevance and accuracy of standardized HRQoL instruments used with YASCC. In a previous study, HRQoL items from several instruments (SF-36, QLACS, QLS-CS) were examined for relevance with a population of YASCC. Participants (n = 30) from this study were recruited for a follow-up qualitative interview to expand on their perceptions of missing content from existing instruments. Respondents reported missing, relevant content among all three of the HRQoL instruments. Results identified three content areas of missing information: (1) Perceived sense of self, (2) Relationships, and (3) Parenthood. Existing HRQoL instruments do not take into account the progression and interdependence of emotional development impacted by a cancer diagnosis. The themes derived from our qualitative interviews may serve as a foundation for the generation of new items in future HRQoL instruments for YASCC populations. Further testing is required to examine the prevalence, frequency, and breadth of these items in a larger sample.

  19. In situ focus characterization by ablation technique to enable optics alignment at an XUV FEL source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerasimova, N.; Dziarzhytski, S.; Weigelt, H.

    2013-06-15

    In situ focus characterization is demonstrated by working at an extreme ultraviolet (XUV) free-electron laser source using ablation technique. Design of the instrument reported here allows reaching a few micrometres resolution along with keeping the ultrahigh vacuum conditions and ensures high-contrast visibility of ablative imprints on optically transparent samples, e.g., PMMA. This enables on-line monitoring of the beam profile changes and thus makes possible in situ alignment of the XUV focusing optics. A good agreement between focal characterizations retrieved from in situ inspection of ablative imprints contours and from well-established accurate ex situ analysis with Nomarski microscope has been observedmore » for a typical micro-focus experiment.« less

  20. First Images from HERO: A Hard-X-Ray Focusing Telescope

    NASA Technical Reports Server (NTRS)

    Ramsey, Brian D.; Alexander, Cheryl D.; Apple, Jeff A.; Benson, Carl M.; Dietz, Kurtis L.; Elsner, Ronald F.; Engelhaupt, Darell E.; Ghosh, Kajal K.; Kolodziejczak, Jeffery J.; ODell, Stephen L.; hide

    2001-01-01

    We are developing a balloon-borne hard-x-ray telescope that utilizes grazing incidence optics. Termed HERO, for High-Energy Replicated Optics, the instrument will provide unprecented sensitivity in the hard-x-ray region and will achieve milliCrab-level sensitivity in a typical 3-hour balloon-flight observation and 50 microCrab sensitivity on ultra-long-duration flights. A recent proof-of-concept flight, featuring a small number of mirror shells captured the first focused hard-x-ray images of galactic x-ray sources. Full details of the payload, its expected future performance and its recent measurements are provided.