Sample records for national accelerator centre

  1. Ion Beam Facilities at the National Centre for Accelerator based Research using a 3 MV Pelletron Accelerator

    NASA Astrophysics Data System (ADS)

    Trivedi, T.; Patel, Shiv P.; Chandra, P.; Bajpai, P. K.

    A 3.0 MV (Pelletron 9 SDH 4, NEC, USA) low energy ion accelerator has been recently installed as the National Centre for Accelerator based Research (NCAR) at the Department of Pure & Applied Physics, Guru Ghasidas Vishwavidyalaya, Bilaspur, India. The facility is aimed to carried out interdisciplinary researches using ion beams with high current TORVIS (for H, He ions) and SNICS (for heavy ions) ion sources. The facility includes two dedicated beam lines, one for ion beam analysis (IBA) and other for ion implantation/ irradiation corresponding to switching magnet at +20 and -10 degree, respectively. Ions with 60 kV energy are injected into the accelerator tank where after stripping positively charged ions are accelerated up to 29 MeV for Au. The installed ion beam analysis techniques include RBS, PIXE, ERDA and channelling.

  2. A new AMS facility at Inter University Accelerator Centre, New Delhi

    NASA Astrophysics Data System (ADS)

    Kumar, Pankaj; Chopra, S.; Pattanaik, J. K.; Ojha, S.; Gargari, S.; Joshi, R.; Kanjilal, D.

    2015-10-01

    Inter University Accelerator Centre (IUAC), a national facility of government of India, is having a 15UD Pelletron accelerator for multidisciplinary ion beam based research programs. Recently, a new accelerator mass spectrometry (AMS) facility has been developed after incorporating many changes in the existing 15UD Pelletron accelerator. A clean chemistry laboratory for 10Be and 26Al with all the modern facilities has also been developed for the chemical processing of samples. 10Be measurements on sediment samples, inter laboratory comparison results and 26Al measurements on standard samples are presented in this paper. In addition to the 10Be and 26Al AMS facilities, a new 14C AMS facility based on a dedicated 500 kV tandem ion accelerator with two cesium sputter ion sources, is also being setup at IUAC.

  3. Acceleration of petaelectronvolt protons in the Galactic Centre

    NASA Astrophysics Data System (ADS)

    HESS Collaboration; Abramowski, A.; Aharonian, F.; Benkhali, F. Ait; Akhperjanian, A. G.; Angüner, E. O.; Backes, M.; Balzer, A.; Becherini, Y.; Tjus, J. Becker; Berge, D.; Bernhard, S.; Bernlöhr, K.; Birsin, E.; Blackwell, R.; Böttcher, M.; Boisson, C.; Bolmont, J.; Bordas, P.; Bregeon, J.; Brun, F.; Brun, P.; Bryan, M.; Bulik, T.; Carr, J.; Casanova, S.; Chakraborty, N.; Chalme-Calvet, R.; Chaves, R. C. G.; Chen, A.; Chrétien, M.; Colafrancesco, S.; Cologna, G.; Conrad, J.; Couturier, C.; Cui, Y.; Davids, I. D.; Degrange, B.; Deil, C.; Dewilt, P.; Djannati-Ataï, A.; Domainko, W.; Donath, A.; Drury, L. O'C.; Dubus, G.; Dutson, K.; Dyks, J.; Dyrda, M.; Edwards, T.; Egberts, K.; Eger, P.; Ernenwein, J.-P.; Espigat, P.; Farnier, C.; Fegan, S.; Feinstein, F.; Fernandes, M. V.; Fernandez, D.; Fiasson, A.; Fontaine, G.; Förster, A.; Füßling, M.; Gabici, S.; Gajdus, M.; Gallant, Y. A.; Garrigoux, T.; Giavitto, G.; Giebels, B.; Glicenstein, J. F.; Gottschall, D.; Goyal, A.; Grondin, M.-H.; Grudzińska, M.; Hadasch, D.; Häffner, S.; Hahn, J.; Hawkes, J.; Heinzelmann, G.; Henri, G.; Hermann, G.; Hervet, O.; Hillert, A.; Hinton, J. A.; Hofmann, W.; Hofverberg, P.; Hoischen, C.; Holler, M.; Horns, D.; Ivascenko, A.; Jacholkowska, A.; Jamrozy, M.; Janiak, M.; Jankowsky, F.; Jung-Richardt, I.; Kastendieck, M. A.; Katarzyński, K.; Katz, U.; Kerszberg, D.; Khélifi, B.; Kieffer, M.; Klepser, S.; Klochkov, D.; Kluźniak, W.; Kolitzus, D.; Komin, Nu.; Kosack, K.; Krakau, S.; Krayzel, F.; Krüger, P. P.; Laffon, H.; Lamanna, G.; Lau, J.; Lefaucheur, J.; Lefranc, V.; Lemiére, A.; Lemoine-Goumard, M.; Lenain, J.-P.; Lohse, T.; Lopatin, A.; Lu, C.-C.; Lui, R.; Marandon, V.; Marcowith, A.; Mariaud, C.; Marx, R.; Maurin, G.; Maxted, N.; Mayer, M.; Meintjes, P. J.; Menzler, U.; Meyer, M.; Mitchell, A. M. W.; Moderski, R.; Mohamed, M.; Morå, K.; Moulin, E.; Murach, T.; de Naurois, M.; Niemiec, J.; Oakes, L.; Odaka, H.; Öttl, S.; Ohm, S.; Opitz, B.; Ostrowski, M.; Oya, I.; Panter, M.; Parsons, R. D.; Arribas, M. Paz; Pekeur, N. W.; Pelletier, G.; Petrucci, P.-O.; Peyaud, B.; Pita, S.; Poon, H.; Prokoph, H.; Pühlhofer, G.; Punch, M.; Quirrenbach, A.; Raab, S.; Reichardt, I.; Reimer, A.; Reimer, O.; Renaud, M.; de Los Reyes, R.; Rieger, F.; Romoli, C.; Rosier-Lees, S.; Rowell, G.; Rudak, B.; Rulten, C. B.; Sahakian, V.; Salek, D.; Sanchez, D. A.; Santangelo, A.; Sasaki, M.; Schlickeiser, R.; Schüssler, F.; Schulz, A.; Schwanke, U.; Schwemmer, S.; Seyffert, A. S.; Simoni, R.; Sol, H.; Spanier, F.; Spengler, G.; Spies, F.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Stinzing, F.; Stycz, K.; Sushch, I.; Tavernet, J.-P.; Tavernier, T.; Taylor, A. M.; Terrier, R.; Tluczykont, M.; Trichard, C.; Tuffs, R.; Valerius, K.; van der Walt, J.; van Eldik, C.; van Soelen, B.; Vasileiadis, G.; Veh, J.; Venter, C.; Viana, A.; Vincent, P.; Vink, J.; Voisin, F.; Völk, H. J.; Vuillaume, T.; Wagner, S. J.; Wagner, P.; Wagner, R. M.; Weidinger, M.; Weitzel, Q.; White, R.; Wierzcholska, A.; Willmann, P.; Wörnlein, A.; Wouters, D.; Yang, R.; Zabalza, V.; Zaborov, D.; Zacharias, M.; Zdziarski, A. A.; Zech, A.; Zefi, F.; Żywucka, N.

    2016-03-01

    Galactic cosmic rays reach energies of at least a few petaelectronvolts (of the order of 1015 electronvolts). This implies that our Galaxy contains petaelectronvolt accelerators (‘PeVatrons’), but all proposed models of Galactic cosmic-ray accelerators encounter difficulties at exactly these energies. Dozens of Galactic accelerators capable of accelerating particles to energies of tens of teraelectronvolts (of the order of 1013 electronvolts) were inferred from recent γ-ray observations. However, none of the currently known accelerators—not even the handful of shell-type supernova remnants commonly believed to supply most Galactic cosmic rays—has shown the characteristic tracers of petaelectronvolt particles, namely, power-law spectra of γ-rays extending without a cut-off or a spectral break to tens of teraelectronvolts. Here we report deep γ-ray observations with arcminute angular resolution of the region surrounding the Galactic Centre, which show the expected tracer of the presence of petaelectronvolt protons within the central 10 parsecs of the Galaxy. We propose that the supermassive black hole Sagittarius A* is linked to this PeVatron. Sagittarius A* went through active phases in the past, as demonstrated by X-ray outburstsand an outflow from the Galactic Centre. Although its current rate of particle acceleration is not sufficient to provide a substantial contribution to Galactic cosmic rays, Sagittarius A* could have plausibly been more active over the last 106-107 years, and therefore should be considered as a viable alternative to supernova remnants as a source of petaelectronvolt Galactic cosmic rays.

  4. "Getting Practical" and the National Network of Science Learning Centres

    ERIC Educational Resources Information Center

    Chapman, Georgina; Langley, Mark; Skilling, Gus; Walker, John

    2011-01-01

    The national network of Science Learning Centres is a co-ordinating partner in the Getting Practical--Improving Practical Work in Science programme. The principle of training provision for the "Getting Practical" programme is a cascade model. Regional trainers employed by the national network of Science Learning Centres trained the cohort of local…

  5. Addiction research centres and the nurturing of creativity: National Drug Dependence Treatment Centre, India--a profile.

    PubMed

    Ray, Rajat; Dhawan, Anju; Chopra, Anita

    2013-10-01

    The National Drug Dependence Treatment Centre (NDDTC) is a part of the All India Institute of Medical Sciences, a premier autonomous medical university in India. This article provides an account of its origin and its contribution to the field of substance use disorder at the national and international levels. Since its establishment, the NDDTC has played a major role in the development of various replicable models of care, the training of post-graduate students of psychiatry, research, policy development and planning. An assessment of the magnitude of drug abuse in India began in the early 1990s and this was followed by a National Survey on Extent, Patterns and Trends of Drug Abuse in 2004. Several models of clinical care have been developed for population subgroups in diverse settings. The centre played an important role in producing data and resource material which helped to scale up opioid substitution treatment in India. A nationwide database on the profile of patients seeking treatment (Drug Abuse Monitoring System) at government drug treatment centres has also been created. The centre has provided valuable inputs for the Government of India's programme planning. Besides clinical studies, research has also focused on pre-clinical studies. Capacity-building is an important priority, with training curricula and resource material being developed for doctors and paramedical staff. Many of these training programmes are conducted in collaboration with other institutions in the country. The NDDTC has received funding from several national and international organizations for research and scientific meetings, and, most recently (2012), it has been designated as a World Health Organization Collaborating Centre on Substance Abuse. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  6. Thomas Jefferson National Accelerator Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grames, Joseph; Higinbotham, Douglas; Montgomery, Hugh

    The Thomas Jefferson National Accelerator Facility (Jefferson Lab) in Newport News, Virginia, USA, is one of ten national laboratories under the aegis of the Office of Science of the U.S. Department of Energy (DOE). It is managed and operated by Jefferson Science Associates, LLC. The primary facility at Jefferson Lab is the Continuous Electron Beam Accelerator Facility (CEBAF) as shown in an aerial photograph in Figure 1. Jefferson Lab was created in 1984 as CEBAF and started operations for physics in 1995. The accelerator uses superconducting radio-frequency (srf) techniques to generate high-quality beams of electrons with high-intensity, well-controlled polarization. Themore » technology has enabled ancillary facilities to be created. The CEBAF facility is used by an international user community of more than 1200 physicists for a program of exploration and study of nuclear, hadronic matter, the strong interaction and quantum chromodynamics. Additionally, the exceptional quality of the beams facilitates studies of the fundamental symmetries of nature, which complement those of atomic physics on the one hand and of high-energy particle physics on the other. The facility is in the midst of a project to double the energy of the facility and to enhance and expand its experimental facilities. Studies are also pursued with a Free-Electron Laser produced by an energy-recovering linear accelerator.« less

  7. Developing substance misuse services in United Arab Emirates: the National Rehabilitation Centre experience

    PubMed Central

    Al Ghaferi, Hamad A.; Ali, Ahmed Y.; Gawad, Tarek A.

    2017-01-01

    In 2001 a directive was issued to establish the National Rehabilitation Centre (NRC) to deal with the growing problem of substance misuse in the United Arab Emirates. The NRC has achieved many goals as a treatment and rehabilitation facility as well as a drug and alcohol demand reduction response centre. It is now working towards being an international centre of excellence. PMID:29093960

  8. Ethical dilemmas of a large national multi-centre study in Australia: time for some consistency.

    PubMed

    Driscoll, Andrea; Currey, Judy; Worrall-Carter, Linda; Stewart, Simon

    2008-08-01

    To examine the impact and obstacles that individual Institutional Research Ethics Committee (IRECs) had on a large-scale national multi-centre clinical audit called the National Benchmarks and Evidence-based National Clinical guidelines for Heart failure management programmes Study. Multi-centre research is commonplace in the health care system. However, IRECs continue to fail to differentiate between research and quality audit projects. The National Benchmarks and Evidence-based National Clinical guidelines for Heart failure management programmes study used an investigator-developed questionnaire concerning a clinical audit for heart failure programmes throughout Australia. Ethical guidelines developed by the National governing body of health and medical research in Australia classified the National Benchmarks and Evidence-based National Clinical guidelines for Heart failure management programmes Study as a low risk clinical audit not requiring ethical approval by IREC. Fifteen of 27 IRECs stipulated that the research proposal undergo full ethical review. None of the IRECs acknowledged: national quality assurance guidelines and recommendations nor ethics approval from other IRECs. Twelve of the 15 IRECs used different ethics application forms. Variability in the type of amendments was prolific. Lack of uniformity in ethical review processes resulted in a six- to eight-month delay in commencing the national study. Development of a national ethics application form with full ethical review by the first IREC and compulsory expedited review by subsequent IRECs would resolve issues raised in this paper. IRECs must change their ethics approval processes to one that enhances facilitation of multi-centre research which is now normative process for health services. The findings of this study highlight inconsistent ethical requirements between different IRECs. Also highlighted are the obstacles and delays that IRECs create when undertaking multi-centre clinical audits

  9. Introducing Mushroom Fruiting Patterns from the Swiss National Poisons Information Centre

    PubMed Central

    Schenk-Jäger, Katharina M.; Egli, Simon; Hanimann, David; Senn-Irlet, Beatrice; Kupferschmidt, Hugo; Büntgen, Ulf

    2016-01-01

    Changes in the ecology of macrofungi are poorly understood, not only because much of their life cycle is hidden belowground, but also because experiments often miss real-world complexity and most fruitbody inventories are limited in space and time. The National Poisons Information Centre ‘Tox Info Suisse’ provides countrywide 24hours/7days medical advice in case of poisonings since 1966. Here, we introduce a total of 12,126 mushroom-related phone calls that were received by Tox Info Suisse between 1966 and 2014. This indirect source of mycological information is dominated by the families of Boletaceae (11%), Agaricaceae (10%) and Amanitaceae (8%), which account for ~30% of all cases. Mushroom fruiting patterns revealed by the Poisons Centre inventory statistically resemble changes in fungal phenology, productivity and diversity as reflected by the Swiss National Data Centre ‘SwissFungi’. Although the newly developed Tox Info Suisse dataset provides an innovative basis for timely environmental research, caution is advised when interpreting some of the observed long-term changes and autumnal extremes. Uncertainty of the new record relates to possible data incompleteness, imprecise species description and/or identification, as well as the inclusion of cultivated and non-indigenous mushrooms. Nevertheless, we hope that the Tox Info Suisse inventory will stimulate and enable a variety of ecological-oriented follow-up studies. PMID:27648562

  10. Introducing Mushroom Fruiting Patterns from the Swiss National Poisons Information Centre.

    PubMed

    Schenk-Jäger, Katharina M; Egli, Simon; Hanimann, David; Senn-Irlet, Beatrice; Kupferschmidt, Hugo; Büntgen, Ulf

    2016-01-01

    Changes in the ecology of macrofungi are poorly understood, not only because much of their life cycle is hidden belowground, but also because experiments often miss real-world complexity and most fruitbody inventories are limited in space and time. The National Poisons Information Centre 'Tox Info Suisse' provides countrywide 24hours/7days medical advice in case of poisonings since 1966. Here, we introduce a total of 12,126 mushroom-related phone calls that were received by Tox Info Suisse between 1966 and 2014. This indirect source of mycological information is dominated by the families of Boletaceae (11%), Agaricaceae (10%) and Amanitaceae (8%), which account for ~30% of all cases. Mushroom fruiting patterns revealed by the Poisons Centre inventory statistically resemble changes in fungal phenology, productivity and diversity as reflected by the Swiss National Data Centre 'SwissFungi'. Although the newly developed Tox Info Suisse dataset provides an innovative basis for timely environmental research, caution is advised when interpreting some of the observed long-term changes and autumnal extremes. Uncertainty of the new record relates to possible data incompleteness, imprecise species description and/or identification, as well as the inclusion of cultivated and non-indigenous mushrooms. Nevertheless, we hope that the Tox Info Suisse inventory will stimulate and enable a variety of ecological-oriented follow-up studies.

  11. SIRIUS - A new 6 MV accelerator system for IBA and AMS at ANSTO

    NASA Astrophysics Data System (ADS)

    Pastuovic, Zeljko; Button, David; Cohen, David; Fink, David; Garton, David; Hotchkis, Michael; Ionescu, Mihail; Long, Shane; Levchenko, Vladimir; Mann, Michael; Siegele, Rainer; Smith, Andrew; Wilcken, Klaus

    2016-03-01

    The Centre for Accelerator Science (CAS) facility at ANSTO has been expanded with a new 6 MV tandem accelerator system supplied by the National Electrostatic Corporation (NEC). The beamlines, end-stations and data acquisition software for the accelerator mass spectrometry (AMS) were custom built by NEC for rare isotope mass spectrometry, while the beamlines with end-stations for the ion beam analysis (IBA) are largely custom designed at ANSTO. An overview of the 6 MV system and its performance during testing and commissioning phase is given with emphasis on the IBA end-stations and their applications for materials modification and characterisation.

  12. AmeriFlux US-IB2 Fermi National Accelerator Laboratory- Batavia (Prairie site)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matamala, Roser

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site US-IB2 Fermi National Accelerator Laboratory- Batavia (Prairie site). Site Description - Two eddy correlation systems are installed at Fermi National Accelerator Laboratory: one on a restored prairie (established October 2004) and one on a corn/soybean rotation agricultural field (established in July 2005). The prairie site had been farmed for more than 100 years, but was converted to prairie in 1989. April annual to bi-annual prescribed burns have taken place from 1994 - 2007.

  13. National data centre preparedness exercise 2015 (NPE2015): MY-NDC progress result and experience

    NASA Astrophysics Data System (ADS)

    Rashid, Faisal Izwan Abdul; Zolkaffly, Muhammed Zulfakar

    2017-01-01

    Malaysia has established the National Data Centre (MY-NDC) in December 2005. MY-NDC is tasked to perform the Comprehensive Nuclear-Test-Ban-Treaty (CTBT) data management as well as providing relevant information for Treaty related events to the Malaysian Nuclear Agency (Nuclear Malaysia) as the CTBT National Authority. In the late 2015, MY-NDC has participated in the National Data Centre Preparedness Exercise 2015 (NPE 2015) which aims to access the level of readiness at MY-NDC. This paper aims at presenting the progress result of NPE 2015 as well as highlighting MY-NDC experience in NPE 2015 compared to previous participation in NPE 2013. MY-NDC has utilised available resources for NPE 2015. In NPE 2015, MY-NDC has performed five type of analyses compared with only two analyses in NPE 2013. Participation in the NPE 2015 has enabled MY-NDC to assess its capability and identify rooms for improvement.

  14. Technical Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    Electrons can “surf” on waves of plasma – a hot gas of charged particles – gaining very high energies in very short distances. This approach, called plasma wakefield acceleration, has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider has been the focus of FACET, a National User Facility at SLAC. FACET used part of SLAC’s two-mile-long linearmore » accelerator to generate high-density beams of electrons and their antimatter counterparts, positrons. Research into plasma wakefield acceleration was the primary motivation for constructing FACET. In April 2016, FACET operations came to an end to make way for the second phase of SLAC’s x-ray laser, the LCLS-II, which will use part of the tunnel occupied by FACET. FACET-II is a new test facility to provide the unique capability to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. FACET-II represents a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique.« less

  15. Brookhaven National Laboratory's Accelerator Test Facility: research highlights and plans

    NASA Astrophysics Data System (ADS)

    Pogorelsky, I. V.; Ben-Zvi, I.

    2014-08-01

    The Accelerator Test Facility (ATF) at Brookhaven National Laboratory has served as a user facility for accelerator science for over a quarter of a century. In fulfilling this mission, the ATF offers the unique combination of a high-brightness 80 MeV electron beam that is synchronized to a 1 TW picosecond CO2 laser. We unveil herein our plan to considerably expand the ATF's floor space with an upgrade of the electron beam's energy to 300 MeV and the CO2 laser's peak power to 100 TW. This upgrade will propel the ATF even further to the forefront of research on advanced accelerators and radiation sources, supporting the most innovative ideas in this field. We discuss emerging opportunities for scientific breakthroughs, including the following: plasma wakefield acceleration studies in research directions already active at the ATF; laser wakefield acceleration (LWFA), where the longer laser wavelengths are expected to engender a proportional increase in the beam's charge while our linac will assure, for the first time, the opportunity to undertake detailed studies of seeding and staging of the LWFA; proton acceleration to the 100-200 MeV level, which is essential for medical applications; and others.

  16. A Nation Deceived: How Schools Hold Back America's Brightest Students. The Templeton National Report on Acceleration. Volume 2

    ERIC Educational Resources Information Center

    Colangelo, Nicholas, Ed.; Assouline, Susan G., Ed.; Gross, Miraca U. M., Ed.

    2004-01-01

    With support from the John Templeton Foundation, the editors held a Summit on Acceleration at The University of Iowa in May 2003. They invited distinguished scholars and educators from around the country to help them formulate a national report on acceleration. Together, they deliberated about what schools need to know in order to make the best…

  17. Regional cancer centre demonstrates voluntary conformity with the national Radiation Oncology Practice Standards

    PubMed Central

    Manley, Stephen; Last, Andrew; Fu, Kenneth; Greenham, Stuart; Kovendy, Andrew; Shakespeare, Thomas P

    2015-01-01

    Radiation Oncology Practice Standards have been developed over the last 10 years and were published for use in Australia in 2011. Although the majority of the radiation oncology community supports the implementation of the standards, there has been no mechanism for uniform assessment or governance. North Coast Cancer Institute's public radiation oncology service is provided across three main service centres on the north coast of NSW. With a strong focus on quality management, we embraced the opportunity to demonstrate conformity with the Radiation Oncology Practice Standards. The Local Health District's Clinical Governance units were engaged to perform assessments of our conformity with the standards and this was signed off as complete on 16 December 2013. The process of demonstrating conformity with the Radiation Oncology Practice Standards has enhanced the culture of quality in our centres. We have demonstrated that self-assessment utilising trained auditors is a viable method for centres to demonstrate conformity. National implementation of the Radiation Oncology Practice Standards will benefit individual centres and the broader radiation oncology community to improve the service delivered to our patients. PMID:26229680

  18. Regional cancer centre demonstrates voluntary conformity with the national Radiation Oncology Practice Standards.

    PubMed

    Manley, Stephen; Last, Andrew; Fu, Kenneth; Greenham, Stuart; Kovendy, Andrew; Shakespeare, Thomas P

    2015-06-01

    Radiation Oncology Practice Standards have been developed over the last 10 years and were published for use in Australia in 2011. Although the majority of the radiation oncology community supports the implementation of the standards, there has been no mechanism for uniform assessment or governance. North Coast Cancer Institute's public radiation oncology service is provided across three main service centres on the north coast of NSW. With a strong focus on quality management, we embraced the opportunity to demonstrate conformity with the Radiation Oncology Practice Standards. The Local Health District's Clinical Governance units were engaged to perform assessments of our conformity with the standards and this was signed off as complete on 16 December 2013. The process of demonstrating conformity with the Radiation Oncology Practice Standards has enhanced the culture of quality in our centres. We have demonstrated that self-assessment utilising trained auditors is a viable method for centres to demonstrate conformity. National implementation of the Radiation Oncology Practice Standards will benefit individual centres and the broader radiation oncology community to improve the service delivered to our patients.

  19. Regional cancer centre demonstrates voluntary conformity with the national Radiation Oncology Practice Standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manley, Stephen, E-mail: stephen.manley@ncahs.health.nsw.gov.au; Last, Andrew; Fu, Kenneth

    Radiation Oncology Practice Standards have been developed over the last 10 years and were published for use in Australia in 2011. Although the majority of the radiation oncology community supports the implementation of the standards, there has been no mechanism for uniform assessment or governance. North Coast Cancer Institute's public radiation oncology service is provided across three main service centres on the north coast of NSW. With a strong focus on quality management, we embraced the opportunity to demonstrate conformity with the Radiation Oncology Practice Standards. The Local Health District's Clinical Governance units were engaged to perform assessments of ourmore » conformity with the standards and this was signed off as complete on 16 December 2013. The process of demonstrating conformity with the Radiation Oncology Practice Standards has enhanced the culture of quality in our centres. We have demonstrated that self-assessment utilising trained auditors is a viable method for centres to demonstrate conformity. National implementation of the Radiation Oncology Practice Standards will benefit individual centres and the broader radiation oncology community to improve the service delivered to our patients.« less

  20. Planetario Habana: A Cultural Centre For Science And Technology In A Developing Nation.

    NASA Astrophysics Data System (ADS)

    Alvarez, Oscar

    2006-08-01

    Astronomical education in Cuba is not widespread in the educational system; nevertheless the public interest in sciences in general but particularly in Astronomy issues is very high as it has become reflected by the attention paid to educational and scientific program broadcasts in the national television channels. The "Planetario Habana" Cultural Centre for Science and Technology under construction is aimed at guiding the interest towards basic sciences and astronomical formation of the people, in the most populated and frequented area of the country. A key objective of this project shall be serving as an instructive motivation and entertainment for the casual or habitual visitors to these facilities, offering them the possibility to enjoy vivid representations, play with interactive amusement equipments and listen to instructive presentations on astronomy and related sciences, all guided by qualified specialists. Another fundamental purpose shall be the establishment of a plan for educational complementation in coordination with schools in order to allow children and young people to participate in activities enabling them to get into the fascinating world of Astronomy, Exploration of Outer Space and Life as Cosmic Phenomenon. The setting up of the Planetario Habana Cultural Centre for Science and Technology under the general administration of the Office of the Historian of the City of Havana, and methodologically lead by the Ministry of Science Technology and Environment, showing in function the GOTO Planetarium G Cuba custom obtained under a Japanese Cultural Grant Aid, shall develop into a nonpareil pole in the national environment for the scientific outreach and education of these sciences. Surrounded by the attractiveness of the colonial "ambience", it shall become a centre for dissemination of information about new discoveries and scientific programs developed at national and international level. Here we present a general view of the project, its present and

  1. The DIY Digital Medical Centre.

    PubMed

    Timmis, James Kenneth; Timmis, Kenneth

    2017-09-01

    Healthcare systems worldwide are confronted with major economic, organizational and logistical challenges. Historic evolution of health care has led to significant healthcare sector fragmentation, resulting in systemic inefficiencies and suboptimal resource exploitation. To attain a sustainable healthcare model, fundamental, system-wide improvements that effectively network, and ensure fulfilment of potential synergies between sectors, and include and facilitate coherent strategic planning and organisation of healthcare infrastructure are needed. Critically, they must be specifically designed to sustainably achieve peak performance within the current policy environment for cost-control, and efficiency and quality improvement for service delivery. We propose creation of a new healthcare cluster, to be embedded in existing healthcare systems. It consists of (i) local 24/7 walk-in virtually autonomous do-it-yourself Digital Medical Centres performing routine diagnosis, monitoring, prevention, treatment and standardized documentation and health outcome assessment/reporting, which are online interfaced with (ii) regional 24/7 eClinician Centres providing on-demand clinical supervision/assistance to Digital Medical Centre patients. Both of these are, in turn, online interfaced with (iii) the National Clinical Informatics Centre, which houses the national patient data centre (cloud) and data analysis units that conduct patient- and population-level, personalized and predictive(-medicine) intervention optimization analyses. The National Clinical Informatics Centre also interfaces with biomedical research and prioritizes and accelerates the translation of new discoveries into clinical practice. The associated Health Policy Innovation and Evaluation Centre rapidly integrates new findings with health policy/regulatory discussions. This new cluster would synergistically link all health system components in a circular format, enable not only access by all arms of the health

  2. Rapid ascent: Rocky Mountain National Park in the Great Acceleration, 1945-present

    NASA Astrophysics Data System (ADS)

    Boxell, Mark

    After the Second World War's conclusion, Rocky Mountain National Park (RMNP) experienced a massive rise in visitation. Mobilized by an affluent economy and a growing, auto-centric infrastructure, Americans rushed to RMNP in droves, setting off new concerns over the need for infrastructure improvements in the park. National parks across the country experienced similar explosions in visitation, inspiring utilities- and road-building campaigns throughout the park units administered by the National Park Service. The quasi-urbanization of parks like RMNP implicated the United States' public lands in a process of global change, whereby wartime technologies, cheap fossil fuels, and a culture of techno-optimism--epitomized by the Mission 66 development program--helped foster a "Great Acceleration" of human alterations of Earth's natural systems. This transformation culminated in worldwide turns toward mass-urbanization, industrial agriculture, and globalized markets. The Great Acceleration, part of the Anthropocene--a new geologic epoch we have likely entered, which proposes that humans have become a force of geologic change--is used as a conceptual tool for understanding the connections between local and global changes which shaped the park after World War II. The Great Acceleration and its array of novel technologies and hydrocarbon-powered infrastructures produced specific cultures of tourism and management techniques within RMNP. After World War II, the park increasingly became the product and distillation of a fossil fuel-dependent society.

  3. The National Poisons Information Centre in Sri Lanka: the first ten years.

    PubMed

    Fernando, Ravindra

    2002-01-01

    Poisoning is a major health concern in Sri Lanka, which has a very high morbidity and mortality from pesticide poisoning. Poisoning, which continues to be in the first five leading causes of death, accounts for about 80,000 hospitalizations and over 3,000 deaths per year. The National Poisons Information Centre in Sri Lanka, thefirst such centre to be established in South Asia, completed 10 years service in 1997. The 4,070 calls received in thefirst 10 years are analyzed and compared with the national hospitalization pattern. The recorded data sheets of all enquiries received from 1988 to 1997 were analyzed retrospectively to study (1) purpose of enquiry, (2) category of enquirer, (3) circumstances of poisoning, (4) gender of victim, (5) age of victim, (6) type of poison, and (7) outcome. Items (6) and (7) were compared with the national hospital statistics for 1998. Of the 4,070 enquiries, 92% concerned specific patients and 6% were for information on poisons. Almost 90% of the enquiries were from medical or paramedical personnel, 5% from relatives or friends, and 3% from the victims. Nearly 38% of enquiries concerned pesticides compared to 27% of poisoning hospitalizations. Medicinal agents were the subject of 20% of enquiries compared to 13% of hospitalizations. The major discrepancy was for snake bites, accounting for only 6% of enquiries but 42% of hospitalizations. Sex distribution of enquiries showed more males than females. Thirty-seven percent of the victims were young adults-15-29years age group. Nearly 49% of the enquiries were for suicidal attempts. Seventy-one percent of the victims recovered. Although enquiries to the NPIC averaged only 0.5% of poisoning hospitalizations, they were sufficiently representative of the national pattern to predict that increasing utilization of the NPIC would offer a much needed service, both for

  4. Beam acceleration through proton radio frequency quadrupole accelerator in BARC

    NASA Astrophysics Data System (ADS)

    Bhagwat, P. V.; Krishnagopal, S.; Mathew, J. V.; Singh, S. K.; Jain, P.; Rao, S. V. L. S.; Pande, M.; Kumar, R.; Roychowdhury, P.; Kelwani, H.; Rama Rao, B. V.; Gupta, S. K.; Agarwal, A.; Kukreti, B. M.; Singh, P.

    2016-05-01

    A 3 MeV proton Radio Frequency Quadrupole (RFQ) accelerator has been designed at the Bhabha Atomic Research Centre, Mumbai, India, for the Low Energy High Intensity Proton Accelerator (LEHIPA) programme. The 352 MHz RFQ is built in 4 segments and in the first phase two segments of the LEHIPA RFQ were commissioned, accelerating a 50 keV, 1 mA pulsed proton beam from the ion source, to an energy of 1.24 MeV. The successful operation of the RFQ gave confidence in the physics understanding and technology development that have been achieved, and indicate that the road forward can now be traversed rather more quickly.

  5. 'Smashed by the National Health'? A Closer Look at the Demise of the Pioneer Health Centre, Peckham.

    PubMed

    Conford, Philip

    2016-04-01

    The Pioneer Health Centre, based in South London before and after the Second World War, remains a source of interest for advocates of a positive approach to health promotion in contrast with the treatment of those already ill. Its closure in 1950 for lack of funds has been blamed on the then recently established National Health Service, but this article argues that such an explanation is over-simplified and ignores a number of other factors. The Centre had struggled financially during the 1930s and tried to gain support from the Medical Research Council. The Council appeared interested in the Centre before the war, but was less sympathetic in the 1940s. Around the time of its closure and afterwards, the Centre was also involved in negotiations with London County Council; these failed because the Centre's directors would not accept the changes which the Council would have needed to make. Unpublished documents reveal that the Centre's directors were uncompromising and that their approach to the situation antagonised their colleagues. Changes in medical science also worked against the Centre. The success of sulphonamide drugs appeared to render preventive medicine less significant, while the development of statistical techniques cast doubt on the Centre's experimental methods. The Centre was at the heart of the nascent organic farming movement, which opposed the rapid growth of chemical cultivation. But what might be termed 'chemical triumphalism' was on the march in both medicine and agriculture, and the Centre was out of tune with the mood of the times.

  6. Automation and Networking of Public Libraries in India Using the E-Granthalaya Software from the National Informatics Centre

    ERIC Educational Resources Information Center

    Matoria, Ram Kumar; Upadhyay, P. K.; Moni, Madaswamy

    2007-01-01

    Purpose: To describe the development of the library management system, e-Granthalaya, for public libraries in India. This is an initiative of the Indian government's National Informatics Centre (NIC). The paper outlines the challenges and the potential of a full-scale deployment of this software at a national level. Design/methodology/approach:…

  7. [Tissue bank of the National Centre for Tumour Disease. An innovative platform for translational tumour].

    PubMed

    Herpel, E; Koleganova, N; Schirmacher, P

    2008-11-01

    The tissue bank of the National Centre for Tumour Diseases (NCT) in Heidelberg, Germany, was founded in 2005 by the University Hospital of Heidelberg and the German Cancer Research Centre as a section of the NCT. It is a nonprofit organization with a completely evaluated legal and ethical framework and supports the Comprehensive Cancer Centre concept. Its main aim is the acquisition and characterization of fresh-frozen and paraffin-embedded human tissues according to the standards of good scientific practice and the promotion of interdisciplinary tumour research of the comprehensive cancer centre and its cooperating partners. It also offers expert project assistance: a project leader can submit a short proposal, and the tissue collecting/preparing process will be performed in cooperation with a specialised pathologist and, if applicable, an experienced clinical researcher. The tissue bank is also a central platform for further developing of innovative technologies for tissue handling, e.g. multi-tissue-array and virtual microscopy, with links to digital image analysis and bioinformatics. Thus, the NCT tissue bank represents a model for innovative biobanking and for institutions with active interdisciplinary cancer research.

  8. Evolution and diversification of National Cleaner Production Centres (NCPCs).

    PubMed

    Van Berkel, Rene

    2010-07-01

    Since 1994 UNIDO and UNEP cooperate in a Programme to establish National Cleaner Production Centres (NCPCs) as a mechanism for delivery of Cleaner Production (CP) services to businesses, governments and other organisations. In 2007, 38 NCPCs were operational in 37 developing and transition countries. While initially set up in near-identical ways in each country, over time NCPCs evolved in response to both programme-internal and country-level factors. The resulting diversity among NCPCs is described and analysed here. Differentiation and specialisation had occurred in service areas or topics both within and between NCPCs, however without a clear strategy for integration and synergy. NCPCs were becoming part of expanding networks of business services providers nationally forcing some to focus on audit and training services (tier 1), and others on specialist services in CP technology and/or policy (tier 2) and/or networking services (tier 3). All NCPCs were on a trajectory from a project management organisation to a nationally-owned entity. The different management requirements were not proactively managed and technical aspects of CP service delivery overshadowed institutional and governance aspects of establishing and operating the NCPC institution. Differences in service delivery methods between NCPCs are most evident in three service areas: CP assessments; policy advice; and transfer of Environmentally Sound Technologies. It is argued here that understanding root causes and benefits of this presently-observed differentiation, could lay the foundation for capturing and advancing best practice CP concepts, methods and policies. This in turn would enable strategic planning for customised interventions and support at the national level. Copyright 2010 Elsevier Ltd. All rights reserved.

  9. The Impact of the Mathematics Support Centre on the Grades of First Year Students at the National University of Ireland Maynooth

    ERIC Educational Resources Information Center

    Mac an Bhaird, Ciaran; Morgan, Tadhg; O'Shea, Ann

    2009-01-01

    In this article, we consider the mathematics grades of first year students at the National University of Ireland Maynooth and the influence that the Mathematics Support Centre (MSC) has on these grades. We will consider the evidence to suggest that the MSC has a positive effect on the grades of the students who attend the centre. It seems to be…

  10. The spinning disc: studying radial acceleration and its damping process with smartphone acceleration sensors

    NASA Astrophysics Data System (ADS)

    Hochberg, K.; Gröber, S.; Kuhn, J.; Müller, A.

    2014-03-01

    Here, we show the possibility of analysing circular motion and acceleration using the acceleration sensors of smartphones. For instance, the known linear dependence of the radial acceleration on the distance to the centre (a constant angular frequency) can be shown using multiple smartphones attached to a revolving disc. As a second example, the decrease of the radial acceleration and the rotation frequency due to friction can be measured and fitted with a quadratic function, in accordance with theory. Finally, because the disc is not set up exactly horizontal, each smartphone measures a component of the gravitational acceleration that adds to the radial acceleration during one half of the period and subtracts from the radial acceleration during the other half. Hence, every graph shows a small modulation, which can be used to determine the rotation frequency, thus converting a ‘nuisance effect’ into a source of useful information, making additional measurements with stopwatches or the like unnecessary.

  11. Cryogenic distribution box for Fermi National Accelerator Laboratory

    NASA Astrophysics Data System (ADS)

    Svehla, M. R.; Bonnema, E. C.; Cunningham, E. K.

    2017-12-01

    Meyer Tool & Mfg., Inc (Meyer Tool) of Oak Lawn, Illinois is manufacturing a cryogenic distribution box for Fermi National Accelerator Laboratory (FNAL). The distribution box will be used for the Muon-to-electron conversion (Mu2e) experiment. The box includes twenty-seven cryogenic valves, two heat exchangers, a thermal shield, and an internal nitrogen separator vessel, all contained within a six-foot diameter ASME coded vacuum vessel. This paper discusses the design and manufacturing processes that were implemented to meet the unique fabrication requirements of this distribution box. Design and manufacturing features discussed include: 1) Thermal strap design and fabrication, 2) Evolution of piping connections to heat exchangers, 3) Nitrogen phase separator design, 4) ASME code design of vacuum vessel, and 5) Cryogenic valve installation.

  12. Role of the "National Reference Centre for Genetically Modified Organisms (GMO) detection" in the official control of food and feed.

    PubMed

    Ciabatti, I; Marchesi, U; Froiio, A; Paternò, A; Ruggeri, M; Amaddeo, D

    2005-08-01

    The National Reference Centre for Genetically Modified Organisms (GMO) detection was established in 2002 within the Istituto Zooprofilattico Sperimentale Lazio e Toscana, with the aim of providing scientific and technical support to the National Health System and to the Ministry of Health within the scope of the regulation of GMO use in food and feed.The recently adopted EU legislation on GMOs (Regulation CE no. 1829/2003 and no. 1830/2003) introduced more rigorous procedures for the authorisation, labelling and analytical control of food and feed consisting, containing or derived from GMOs. The National Reference Centre, besides its institutional tasks as one of the laboratories of the Italian National Health System, collects and analyses data and results of the national official control of GMOs; carries out scientific research aimed at developing, improving, validating and harmonising detection and quantification methods, in cooperation with other scientific institutions, the Community Reference Laboratory and within the European Network of GMOs laboratories (ENGL); collaborates with the Ministry of Health in the definition of control programmes and promotes educational and training initiatives. Objectives defined for 2004-2006, activities in progress and goals already achieved are presented.

  13. The accelerator facility of the Heidelberg Ion-Beam Therapy Centre (HIT)

    NASA Astrophysics Data System (ADS)

    Peters, Andreas

    The following sections are included: * Introduction * Beam parameters * General layout of the HIT facility * The accelerator chain in detail * Operational aspects of a particle therapy facility * 24/7 accelerator operation at 335 days per year * Safety and regulatory aspects * Status and perspectives * References

  14. Muscle contributions to the acceleration of the whole body centre of mass during recovery from forward loss of balance by stepping in young and older adults.

    PubMed

    Graham, David F; Carty, Christopher P; Lloyd, David G; Barrett, Rod S

    2017-01-01

    The purpose of this study was to determine the muscular contributions to the acceleration of the whole body centre of mass (COM) of older compared to younger adults that were able to recover from forward loss of balance with a single step. Forward loss of balance was achieved by releasing participants (14 older adults and 6 younger adults) from a static whole-body forward lean angle of approximately 18 degrees. 10 older adults and 6 younger adults were able to recover with a single step and included in subsequent analysis. A scalable anatomical model consisting of 36 degrees-of-freedom was used to compute kinematics and joint moments from motion capture and force plate data. Forces for 92 muscle actuators were computed using Static Optimisation and Induced Acceleration Analysis was used to compute individual muscle contributions to the three-dimensional acceleration of the whole body COM. There were no significant differences between older and younger adults in step length, step time, 3D COM accelerations or muscle contributions to 3D COM accelerations. The stance and stepping leg Gastrocnemius and Soleus muscles were primarily responsible for the vertical acceleration experienced by the COM. The Gastrocnemius and Soleus from the stance side leg together with bilateral Hamstrings accelerated the COM forwards throughout balance recovery while the Vasti and Soleus of the stepping side leg provided the majority of braking accelerations following foot contact. The Hip Abductor muscles provided the greatest contribution to medial-lateral accelerations of the COM. Deficits in the neuromuscular control of the Gastrocnemius, Soleus, Vasti and Hip Abductors in particular could adversely influence balance recovery and may be important targets in interventions to improve balance recovery performance.

  15. Accelerating Innovation that Enhances Resource Recovery in the Wastewater Sector: Advancing a National Testbed Network.

    PubMed

    Mihelcic, James R; Ren, Zhiyong Jason; Cornejo, Pablo K; Fisher, Aaron; Simon, A J; Snyder, Seth W; Zhang, Qiong; Rosso, Diego; Huggins, Tyler M; Cooper, William; Moeller, Jeff; Rose, Bob; Schottel, Brandi L; Turgeon, Jason

    2017-07-18

    This Feature examines significant challenges and opportunities to spur innovation and accelerate adoption of reliable technologies that enhance integrated resource recovery in the wastewater sector through the creation of a national testbed network. The network is a virtual entity that connects appropriate physical testing facilities, and other components needed for a testbed network, with researchers, investors, technology providers, utilities, regulators, and other stakeholders to accelerate the adoption of innovative technologies and processes that are needed for the water resource recovery facility of the future. Here we summarize and extract key issues and developments, to provide a strategy for the wastewater sector to accelerate a path forward that leads to new sustainable water infrastructures.

  16. ‘Smashed by the National Health’? A Closer Look at the Demise of the Pioneer Health Centre, Peckham

    PubMed Central

    Conford, Philip

    2016-01-01

    The Pioneer Health Centre, based in South London before and after the Second World War, remains a source of interest for advocates of a positive approach to health promotion in contrast with the treatment of those already ill. Its closure in 1950 for lack of funds has been blamed on the then recently established National Health Service, but this article argues that such an explanation is over-simplified and ignores a number of other factors. The Centre had struggled financially during the 1930s and tried to gain support from the Medical Research Council. The Council appeared interested in the Centre before the war, but was less sympathetic in the 1940s. Around the time of its closure and afterwards, the Centre was also involved in negotiations with London County Council; these failed because the Centre’s directors would not accept the changes which the Council would have needed to make. Unpublished documents reveal that the Centre’s directors were uncompromising and that their approach to the situation antagonised their colleagues. Changes in medical science also worked against the Centre. The success of sulphonamide drugs appeared to render preventive medicine less significant, while the development of statistical techniques cast doubt on the Centre’s experimental methods. The Centre was at the heart of the nascent organic farming movement, which opposed the rapid growth of chemical cultivation. But what might be termed ‘chemical triumphalism’ was on the march in both medicine and agriculture, and the Centre was out of tune with the mood of the times. PMID:26971599

  17. Muscle contributions to the acceleration of the whole body centre of mass during recovery from forward loss of balance by stepping in young and older adults

    PubMed Central

    Graham, David F.; Carty, Christopher P.; Lloyd, David G.

    2017-01-01

    The purpose of this study was to determine the muscular contributions to the acceleration of the whole body centre of mass (COM) of older compared to younger adults that were able to recover from forward loss of balance with a single step. Forward loss of balance was achieved by releasing participants (14 older adults and 6 younger adults) from a static whole-body forward lean angle of approximately 18 degrees. 10 older adults and 6 younger adults were able to recover with a single step and included in subsequent analysis. A scalable anatomical model consisting of 36 degrees-of-freedom was used to compute kinematics and joint moments from motion capture and force plate data. Forces for 92 muscle actuators were computed using Static Optimisation and Induced Acceleration Analysis was used to compute individual muscle contributions to the three-dimensional acceleration of the whole body COM. There were no significant differences between older and younger adults in step length, step time, 3D COM accelerations or muscle contributions to 3D COM accelerations. The stance and stepping leg Gastrocnemius and Soleus muscles were primarily responsible for the vertical acceleration experienced by the COM. The Gastrocnemius and Soleus from the stance side leg together with bilateral Hamstrings accelerated the COM forwards throughout balance recovery while the Vasti and Soleus of the stepping side leg provided the majority of braking accelerations following foot contact. The Hip Abductor muscles provided the greatest contribution to medial-lateral accelerations of the COM. Deficits in the neuromuscular control of the Gastrocnemius, Soleus, Vasti and Hip Abductors in particular could adversely influence balance recovery and may be important targets in interventions to improve balance recovery performance. PMID:29069097

  18. Fifty years of accelerator based physics at Chalk River

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKay, John W.

    1999-04-26

    The Chalk River Laboratories of Atomic Energy of Canada Ltd. was a major centre for Accelerator based physics for the last fifty years. As early as 1946, nuclear structure studies were started on Cockroft-Walton accelerators. A series of accelerators followed, including the world's first Tandem, and the MP Tandem, Superconducting Cyclotron (TASCC) facility that was opened in 1986. The nuclear physics program was shut down in 1996. This paper will describe some of the highlights of the accelerators and the research of the laboratory.

  19. Illinois Accelerator Research Center

    DOE PAGES

    Kroc, Thomas K.; Cooper, Charlie A.

    2017-10-26

    The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi's state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 ft2 heavy assembly building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Connected to the HAB is a 47,000 ft Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building, whichmore » contains the Accelerator Physics Center, and nearby Accelerator and Technical divisions provide IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. Finally, at IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security.« less

  20. Illinois Accelerator Research Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroc, Thomas K.; Cooper, Charlie A.

    The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi's state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 ft2 heavy assembly building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Connected to the HAB is a 47,000 ft Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building, whichmore » contains the Accelerator Physics Center, and nearby Accelerator and Technical divisions provide IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. Finally, at IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security.« less

  1. Illinois Accelerator Research Center

    NASA Astrophysics Data System (ADS)

    Kroc, Thomas K.; Cooper, Charlie A.

    The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi's state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 ft2 Heavy Assembly Building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Connected to the HAB is a 47,000 ft2 Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building, which contains the Accelerator Physics Center, and nearby Accelerator and Technical divisions provide IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. At IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security.

  2. Seismological investigation of the National Data Centre Preparedness Exercise 2013

    NASA Astrophysics Data System (ADS)

    Gestermann, Nicolai; Hartmann, Gernot; Ross, J. Ole; Ceranna, Lars

    2015-04-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) prohibits all kinds of nuclear explosions conducted on Earth - underground, underwater or in the atmosphere. The verification regime of the CTBT is designed to detect any treaty violation. While the data of the International Monitoring System (IMS) is collected, processed and technically analyzed at the International Data Centre (IDC) of the CTBT-Organization, National Data Centres (NDC) of the member states provide interpretation and advice to their government concerning suspicious detections. The NDC Preparedness Exercises (NPE) are regularly performed dealing with fictitious treaty violations to practice the combined analysis of CTBT verification technologies. These exercises should help to evaluate the effectiveness of analysis procedures applied at NDCs and the quality, completeness and usefulness of IDC products for example. The exercise trigger of NPE2013 is a combination of a tempo-spatial indication pointing to a certain waveform event and simulated radionuclide concentrations generated by forward Atmospheric Transport Modelling based on a fictitious release. For the waveform event the date (4 Sept. 2013) is given and the region is communicated in a map showing the fictitious state of "Frisia" at the Coast of the North Sea in Central Europe. The potential connection between the waveform and radionuclide evidence remains unclear for exercise participants. The verification task was to identify the waveform event and to investigate potential sources of the radionuclide findings. The final question was whether the findings are CTBT relevant and justify a request for On-Site-Inspection in "Frisia". The seismic event was not included in the Reviewed Event Bulletin (REB) of the IDC. The available detections from the closest seismic IMS stations lead to a epicenter accuracy of about 24 km which is not sufficient to specify the 1000 km2 inspection area in case of an OSI. With use of data from local stations and

  3. Minister unveils new nanotech centres

    NASA Astrophysics Data System (ADS)

    Dumé, Belle

    2009-06-01

    Three new nanotechnology research centres are to be set up in France as part of a €70m government plan to help French companies in the sector. Researchers at the new centres, which will be located in Grenoble, Saclay (near Paris) and Toulouse, will be encouraged to collaborate with industry to develop new nanotech-based products. Dubbed NANO-INNOV, the new plan includes €46m for two new buildings at Saclay, with the rest being used to buy new equipment at the three centres and to fund grant proposals from staff to the French National Research Agency (ANR).

  4. The Accelerated Schools Movement: Expansion and Support through Accelerated Schools Centers.

    ERIC Educational Resources Information Center

    Brunner, Ilse; And Others

    From 1987 to 1995, the Accelerated Schools Project moved from a two-school pilot project to a national movement of over 700 schools in 35 states. This paper examines how the Accelerated Schools Centers have helped the expansion of the accelerated schools movement by recruiting and supporting schools in their regions, and how their institutional…

  5. Canadian Educational Development Centre Websites: More Ebb than Flow?

    ERIC Educational Resources Information Center

    Simmons, Nicola

    2010-01-01

    This paper examines information portrayed on Canadian educational development (ED) centre websites and, in particular, whether information that corresponds to questions compiled from a literature search of ED centre practices is readily available from centre websites. This study phase is part of a larger national study of Canadian educational…

  6. [The National Reference Centres and Reference Laboratories. Importance and tasks].

    PubMed

    Laude, G; Ammon, A

    2005-09-01

    Since 1995, the German Federal Ministry for Health and Social Security funds National Reference Centres (NRC) for the laboratory surveillance of important pathogens and syndromes. Which pathogens or syndromes are selected to be covered by a NRC depends on their epidemiological relevance, the special diagnostic tools, problems with antimicrobial resistance and necessary infection control measures. Currently, there are 15 NRC, which are appointed for a period of 3 years (currently from January 2005 through December 2007). Towards the end of their appointment all NRC are evaluated by a group of specialists. The assessment of their achievements is guided by a catalogue of tasks for the NRC. In addition to the NRC, a total of 50 laboratories are appointed which provide specialist expertise for additional pathogens in order to have a broad range of pathogens for which specialist laboratories are available. Their predominant task is to give advice and support for special diagnostic problems. Both NRC and the specialist laboratories are important parts of the network for infectious disease epidemiology.

  7. UK Renal Registry 16th annual report: chapter 13 clinical, haematological and biochemical parameters in patients receiving renal replacement therapy in paediatric centres in the uk in 2012: national and centre-specific analyses.

    PubMed

    Pruthi, Rishi; Maxwell, Heather; Casula, Anna; Braddon, Fiona; Lewis, Malcolm; O'Brien, Catherine; Stojanovic, Jelena; Tse, Yincent; Inward, Carol; Sinha, Manish D

    2013-01-01

    The British Association for Paediatric Nephrology Registry (BAPN) was established to analyse data related to renal replacement therapy (RRT) in children. The registry receives data from the 13 paediatric nephrology centres in the UK. This chapter aims to provide centre specific data so that individual centres can reflect on the contribution that their data makes to the national picture and to determine the extent to which their patient parameters meet nationally agreed audit standards for the management of children with established renal failure (ERF). Data returns included a mixture of electronic (92%) and paper (8%) returns. Data were analysed to calculate summary statistics and where applicable the percentage achieving an audit standard. The standards used were those set out by the Renal Association and the National Institute for Health and Clinical Excellence. Anthropometric data confirmed that children receiving RRT were short compared to healthy peers. Amongst patients with a height of <2SD between 2001 and 2012, 29.2%were receiving growth hormone if they were on dialysis compared to 11.9% if they had a functioning transplant. Prevalence rates of overweight and obese status in children with ERF remain concerningly high. Blood pressure control remained challenging with wide inter-centre variation although this was significantly better in children with a functioning transplant. Over a quarter of haemodialysis patients and 17.3% of peritoneal dialysis patients were anaemic, compared to only 8.3% of transplanted patients. ESA use in the dialysis population exceeded 90% amongst anaemic patients. The control of renal bone disease remained challenging. Optimising growth and reducing prevalent excess weight in children on RRT remains challenging. The likelihood of complete electronic reporting in the near future with plans for quarterly reporting in the format of the recently finalised NEW paediatric dataset will hopefully improve quality of data and their reporting

  8. IARC - Illinois Accelerator Research Center | Pilot Program

    Science.gov Websites

    Toggle navigation Pilot Program Agenda Directions Registration Illinois Accelerator Research Center National Laboratory present Accelerator Stewardship Test Facility Pilot Program Use accelerator technology , energy and environment. With this pilot program, the DOE Office of Science National Laboratories are

  9. The Isis Centre: a counselling service within the National Health Service.

    PubMed Central

    Agulnik, P; Holroyd, P; Mandelbrote, B

    1976-01-01

    A new centre has been established to provide readily accessible counselling, consultation, and mental health information. People may refer themselves or are recommended to attend by general practitioners or other agencies. The counsellors have varied backgrounds in paramedical or counselling services, and they are supported by psychiatrists. Of a sample of 100 clients, four were referred to one of the team's psychiatrists and 33 visited the centre only once. The centre's staff aim to adopt a flexible approach to the client and his problems, and formal psychiatric categories have not been found useful. Provision is made for people who want to solve their problems by discussion rather than medication and those for whom the existing psychiatric services may have little time to spare. Consequently, the approach adopted by the Isis Centre, whereby many people benefit from psychotherapy yet the psychiatrist deals directly with only a few selected cases, contributes towards meeting the great need for psychiatric services and using the psychiatrist's skills more effectively. PMID:947421

  10. RF cavity design and qualification for proton accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teotia, Vikas; Malhotra, Sanjay; Ukarde, Priti

    Alvarez type Drift Tube Linac (DTL) is used for acceleration of proton beam in low energy section of beta ranging from 0.04 to 0.40. DTL is cylindrical RF cavity resonating in TM010 mode at 352.21 MHz frequency. It consists of array of drift tubes arranged ensuring that DTL centre and Drift Tube centre are concentric. The Drift Tubes also houses Permanent Magnet Quadrupole for transverse focusing of proton beam. A twelve cell prototype of DTL section is designed, developed and fabricated at Bhabha Atomic Research Centre, Trombay. Complete DTL accelerator consists of eight such DTL sections. High frequency microwave simulationsmore » are carried out in SOPRANO, vector fields and COMSOL simulation software. This prototype DTL is 1640.56 mm long cavity with 520 mm ID, 600 mm OD and consists of eleven Drift Tubes, two RF end flanges, three slug tuners, six post couplers, three RF field monitors, one RF waveguide coupler, two DN100 vacuum flanges and DTL tank platform with alignment features. Girder based Drift tube mounting arrangement utilizing uncompressing energy of disc springs for optimum combo RF-vacuum seal compression is worked out and implemented. This paper discusses design of this RF vacuum cavity operating at high accelerating field gradient in ultra-high vacuum. Detailed vacuum design and results of RF and vacuum qualifications are discussed. Results on mechanical accuracy achieved on scaled pre-prototype are also presented. Paper summarizes the engineering developments carried out for this RF cavity and brings out the future activities proposed in indigenous development of high gradient RF cavities for ion accelerators. (author)« less

  11. [Definition of endometriosis expert centres].

    PubMed

    Chanavaz-Lacheray, I; Darai, E; Descamps, P; Agostini, A; Poilblanc, M; Rousset, P; Bolze, P-A; Panel, P; Collinet, P; Hebert, T; Graesslin, O; Martigny, H; Brun, J-L; Dechaud, H; Mezan De Malartic, C; Piechon, L; Wattiez, A; Chapron, C; Golfier, F

    2018-03-01

    The Collège national des gynécologues obstétriciens français (CNGOF), in agreement with the Société de chirurgie gynécologique et pelvienne (SCGP), has set up a commission in 2017 to define endometriosis expert centres, with the aim of optimizing endometriosis care in France. The committee included members from university and general hospitals as well as private facilities, representing medical, surgical and radiological aspects of endometriosis care. Opinion of endometriosis patients' associations was obtained prior to writing this work. The final text was presented and unanimously validated by the members of the CNGOF Board of Directors at its meeting of October 13, 2017. Based on analysis of current management of endometriosis and the last ten years opportunities in France, the committee has been able to define the contours of endometriosis expert centres. The objectives, production specifications, mode of operation, missions and funding for these centres were described. The following missions have been specifically defined: territorial organization, global and referral care, communication and teaching as well as research and evaluation. Because of its daily impact for women and its economic burden in France, endometriosis justifies launching of expert centres throughout the country with formal accreditation by health authorities, ideally as part of the National Health Plan. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. Birth centres and the national maternity services review: response to consumer demand or compromise?

    PubMed

    Dahlen, H; Jackson, M; Schmied, V; Tracy, S; Priddis, H

    2011-12-01

    In February 2009 the Improving Maternity Services in Australia - The Report of the Maternity Services Review (MSR) was released and recommended improving women's access to and availability of birth centres. It was unclear if this was in response to an overwhelming request for birth centres in the submissions received by the commonwealth or a compromise for excluding homebirth from the maternity service reforms. The aim of this paper was to examine what was said in the submissions to the MSR about birth centres. Data for this study comprised 832 submissions to the MSR that are publicly available on the Commonwealth of Australia Department of Health and Ageing website. All 832 submissions were downloaded, and read for any mention of the words 'birth centre', 'birth center'. Content analysis was used to categorise and report the data. Of the 832 submissions to the MSR 197 (24%) mentioned birth centres while 470 (60%) of the submissions mentioned homebirth. Only 31 (4%) of the submissions to the Maternity Review mentioned birth centres without mentioning home birth also. Most of the submissions emphasised that 'everything should be on the menu' when it came to place of birth and care provider. Reasons for choosing a birth centre were identified as: 'the best compromise available, 'the right and natural way' and 'the birth centre as safe'. Women had certain requirements of a birth centre that included: 'continuity of carer', 'midwife led', 'a sanctum from medicalised care', 'resources to cope with demand', 'close to home', and 'flexible guidelines and admission criteria'. Women weighed up a series of requirements when deciding whether to give birth in a birth centre. The recommendation by the MSR to expand birth centres and ignore home birth is at odds with the strong view expressed that 'everything should be on the menu'. The requirements women described of birth centre care are also at odds with current trends. If there is to be an expansion of birth centres, service

  13. Tiger Team Assessment of the Fermi National Accelerator Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-01

    This draft report documents the Tiger Team Assessment of the Fermi National Accelerator Laboratory (Fermilab) located in Batavia, Illinois. Fermilab is a program-dedicated national laboratory managed by the Universities Research Association, Inc. (URA) for the US Department of Energy (DOE). The Tiger Team Assessment was conducted from May 11 to June 8, 1992, under the auspices of DOE's Office of Special Projects (OSP) under the Office of the Assistant Secretary for Environment, Safety and Health (EH). The assessment was comprehensive, encompassing environmental, safety and health (ES H), and quality assurance (QA) disciplines; site remediation; facilities management; and waste management operations.more » Compliance with applicable Federal , State of Illinois, and local regulations; applicable DOE Orders; best management practices; and internal Fermilab requirements was addressed. In addition, an evaluation of the effectiveness of DOE and Fermilab management of the ES H/QA and self-assessment programs was conducted. The Fermilab Tiger Team Assessment is part a larger, comprehensive DOE Tiger Team Independent Assessment Program planned for DOE facilities. The objective of the initiative is to provide the Secretary of Energy with information on the compliance status of DOE facilities with regard to ES H requirements, root causes for noncompliance, adequacy of DOE and contractor ES H management programs, response actions to address the identified problem areas, and DOE-wide ES H compliance trends and root causes.« less

  14. Tiger Team Assessment of the Fermi National Accelerator Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-01

    This draft report documents the Tiger Team Assessment of the Fermi National Accelerator Laboratory (Fermilab) located in Batavia, Illinois. Fermilab is a program-dedicated national laboratory managed by the Universities Research Association, Inc. (URA) for the US Department of Energy (DOE). The Tiger Team Assessment was conducted from May 11 to June 8, 1992, under the auspices of DOE`s Office of Special Projects (OSP) under the Office of the Assistant Secretary for Environment, Safety and Health (EH). The assessment was comprehensive, encompassing environmental, safety and health (ES&H), and quality assurance (QA) disciplines; site remediation; facilities management; and waste management operations. Compliancemore » with applicable Federal , State of Illinois, and local regulations; applicable DOE Orders; best management practices; and internal Fermilab requirements was addressed. In addition, an evaluation of the effectiveness of DOE and Fermilab management of the ES&H/QA and self-assessment programs was conducted. The Fermilab Tiger Team Assessment is part a larger, comprehensive DOE Tiger Team Independent Assessment Program planned for DOE facilities. The objective of the initiative is to provide the Secretary of Energy with information on the compliance status of DOE facilities with regard to ES&H requirements, root causes for noncompliance, adequacy of DOE and contractor ES&H management programs, response actions to address the identified problem areas, and DOE-wide ES&H compliance trends and root causes.« less

  15. Proceedings of the 1995 Particle Accelerator Conference and international Conference on High-Energy Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1996-01-01

    Papers from the sixteenth biennial Particle Accelerator Conference, an international forum on accelerator science and technology held May 1–5, 1995, in Dallas, Texas, organized by Los Alamos National Laboratory (LANL) and Stanford Linear Accelerator Center (SLAC), jointly sponsored by the Institute of Electrical and Electronics Engineers (IEEE) Nuclear and Plasma Sciences Society (NPSS), the American Physical Society (APS) Division of Particles and Beams (DPB), and the International Union of Pure and Applied Physics (IUPAP), and conducted with support from the US Department of Energy, the National Science Foundation, and the Office of Naval Research.

  16. Initiation of non-invasive ventilation in amyotrophic lateral sclerosis and clinical practice guidelines: Single-centre, retrospective, descriptive study in a national reference centre.

    PubMed

    Georges, Marjolaine; Golmard, Jean-Louis; Llontop, Claudia; Shoukri, Amr; Salachas, François; Similowski, Thomas; Morelot-Panzini, Capucine; Gonzalez-Bermejo, Jésus

    2017-02-01

    In amyotrophic lateral sclerosis (ALS), respiratory muscle weakness leads to respiratory failure. Non-invasive ventilation (NIV) maintains adequate ventilation in ALS patients. NIV alleviates symptoms and improves survival. In 2006, French guidelines established criteria for NIV initiation based on limited evidence. Their impact on clinical practice remains unknown. Our objective was to describe NIV initiation practices of the main French ALS tertiary referral centre with respect to guidelines. In this retrospective descriptive study, 624 patients followed in a single national reference centre began NIV between 2005 and 2013. We analysed criteria used to initiate NIV, including symptoms, PaCO 2 , forced vital capacity, maximal inspiratory pressures and time spent with SpO 2 <90% at night. At NIV initiation, 90% of patients were symptomatic. Median PaCO 2 was 48 mmHg. The main criterion to initiate NIV was 'symptoms' followed by 'hypercapnia' in 42% and 34% of cases, respectively. NIV was initiated on functional parameters in only 5% of cases. Guidelines were followed in 81% of cases. In conclusion, despite compliance with French guidelines, the majority of patients are treated at the stage of symptomatic daytime hypoventilation, which suggests that NIV is initiated late in the course of ALS. Whether this practice could be improved by changing guidelines or increasing respiratory-dedicated resources remains to be determined.

  17. Assuring optimal trauma care: the role of trauma centre accreditation

    PubMed Central

    Simons, Richard; Kirkpatrick, Andrew

    2002-01-01

    Optimal care of the injured patient requires the delivery of appropriate, definitive care shortly after injury. Over the last 30 to 40 years, civilian trauma systems and trauma centres have been developed in the United States based on experience gained in military conflicts, particularly in Korea and Vietnam. A similar process is evolving in Canada. National trauma committees in the US and Canada have defined optimal resources to meet the goal of rapid, appropriate care in trauma centres. They have introduced programs (verification or accreditation) to externally audit trauma centre performance based on these guidelines. It is generally accepted that implementing trauma systems results in decreased preventable death and improved survival after trauma. What is less clear is the degree to which each facet of trauma system development contributes to this improvement. The relative importance of national performance guidelines and trauma centre audit as integral steps toward improved outcomes following injury are reviewed. Current Trauma Association of Canada guidelines for trauma centres are presented and the process of trauma centre accreditation is discussed. PMID:12174987

  18. Sustaining the Leaders of Children's Centres: The Role of Leadership Mentoring

    ERIC Educational Resources Information Center

    John, Karen

    2008-01-01

    Leadership mentoring is a central component of the National Professional Qualification in Integrated Centre Leadership (NPQICL), which is designed to develop robust, creative and courageous children's centre leaders. Mentoring provides a safe, supportive and confidential space in which leaders can discuss the challenges of leading their centres.…

  19. Development of the Accelerator Mass Spectrometry technology at the Comenius University in Bratislava

    NASA Astrophysics Data System (ADS)

    Povinec, Pavel P.; Masarik, Jozef; Ješkovský, Miroslav; Kaizer, Jakub; Šivo, Alexander; Breier, Robert; Pánik, Ján; Staníček, Jaroslav; Richtáriková, Marta; Zahoran, Miroslav; Zeman, Jakub

    2015-10-01

    An Accelerator Mass Spectrometry (AMS) laboratory has been established at the Centre for Nuclear and Accelerator Technologies (CENTA) at the Comenius University in Bratislava comprising of a MC-SNICS ion source, 3 MV Pelletron tandem accelerator, and an analyzer of accelerated ions. The preparation of targets for 14C and 129I AMS measurements is described in detail. The development of AMS techniques for potassium, uranium and thorium analysis in radiopure materials required for ultra-low background underground experiments is briefly mentioned.

  20. Pulse - Accelerator Science in Medicine

    Science.gov Websites

    discoveries in particle accelerator science may lead to unexpected applications for medical diagnosis, healing perhaps to new tools for medical science. National laboratories build particle accelerators for physicists

  1. US Particle Accelerators at Age 50.

    ERIC Educational Resources Information Center

    Wilson, R. R.

    1981-01-01

    Reviews the development of accelerators over the past 50 years. Topics include: types of accelerators, including cyclotrons; sociology of accelerators (motivation, financing, construction, and use); impact of war; national laboratories; funding; applications; future projects; foreign projects; and international collaborations. (JN)

  2. High Gradient Accelerator Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Temkin, Richard

    The goal of the MIT program of research on high gradient acceleration is the development of advanced acceleration concepts that lead to a practical and affordable next generation linear collider at the TeV energy level. Other applications, which are more near-term, include accelerators for materials processing; medicine; defense; mining; security; and inspection. The specific goals of the MIT program are: • Pioneering theoretical research on advanced structures for high gradient acceleration, including photonic structures and metamaterial structures; evaluation of the wakefields in these advanced structures • Experimental research to demonstrate the properties of advanced structures both in low-power microwave coldmore » test and high-power, high-gradient test at megawatt power levels • Experimental research on microwave breakdown at high gradient including studies of breakdown phenomena induced by RF electric fields and RF magnetic fields; development of new diagnostics of the breakdown process • Theoretical research on the physics and engineering features of RF vacuum breakdown • Maintaining and improving the Haimson / MIT 17 GHz accelerator, the highest frequency operational accelerator in the world, a unique facility for accelerator research • Providing the Haimson / MIT 17 GHz accelerator facility as a facility for outside users • Active participation in the US DOE program of High Gradient Collaboration, including joint work with SLAC and with Los Alamos National Laboratory; participation of MIT students in research at the national laboratories • Training the next generation of Ph. D. students in the field of accelerator physics.« less

  3. Exploring the mechanical basis for acceleration: pelvic limb locomotor function during accelerations in racing greyhounds (Canis familiaris)

    PubMed Central

    Williams, S. B.; Usherwood, J. R.; Jespers, K.; Channon, A. J.; Wilson, A. M.

    2009-01-01

    Summary Animals in their natural environments are confronted with a regular need to perform rapid accelerations (for example when escaping from predators or chasing prey). Such acceleration requires net positive mechanical work to be performed on the centre of mass by skeletal muscle. Here we determined how pelvic limb joints contribute to the mechanical work and power that are required for acceleration in galloping quadrupeds. In addition, we considered what, if any, biomechanical strategies exist to enable effective acceleration to be achieved. Simultaneous kinematic and kinetic data were collected for racing greyhounds undergoing a range of low to high accelerations. From these data, joint moments and joint powers were calculated for individual hindlimb joints. In addition, the mean effective mechanical advantage (EMA) of the limb and the `gear ratio' of each joint throughout stance were calculated. Greatest increases in joint work and power with acceleration appeared at the hip and hock joints, particularly in the lead limb. Largest increases in absolute positive joint work occurred at the hip, consistent with the hypothesis that quadrupeds power locomotion by torque about the hip. In addition, hindlimb EMA decreased substantially with increased acceleration – a potential strategy to increase stance time and thus ground impulses for a given peak force. This mechanism may also increase the mechanical advantage for applying the horizontal forces necessary for acceleration. PMID:19181903

  4. The new policy of the Food and Agriculture Organization of the United Nations and its Reference Centres for the Animal Production and Health Division.

    PubMed

    Lubroth, J

    2007-01-01

    The article explains the current procedures to be followed for institutes that are, were or would like to become Reference Centres for the Food and Agriculture Organization (FAO) of the United Nations. Within the realm of animal health many of the Reference Laboratories and Reference Centres of the World Organisation for Animal Health (OIE) are the same as those of the Animal and Health Division of FAO, particularly for diseases that are transboundary in nature, but they also address other aspects concerning health, production, standard setting, agriculture, conservation, water, and biotechnology.

  5. The Hellenic National Tsunami Warning Centre (HL-NTWC): Recent updates and future developments

    NASA Astrophysics Data System (ADS)

    Melis, Nikolaos S.; Charalampakis, Marinos

    2014-05-01

    The Hellenic NTWC (HL-NTWC) was established officially by Greek Law in September 2010. HL-NTWC is hosted at the National Observatory of Athens, Institute of Geodynamics (NOA-IG), which also operates a 24/7 earthquake monitoring service in Greece and coordinates the newly established Hellenic Unified National Seismic Network. NOA-IG and HL-NTWC Operational Centre is linked to the Civil Protection Operational Centre and serves as the official alerting agency to the General Secretariat for Civil Protection in Greece, regarding earthquake events and tsunami watch. Since August 2012, HL-NTWC acts as Candidate Tsunami Watch Provider (CTWP) under the UNESCO IOC - ICG NEAMTWS tsunami warning system (NEAM: North-Eastern Atlantic, the Mediterranean and connected seas) and offers its services to the NEAMTWS system. HL-NTWC has participated in all Communication Test Exercises (CTE) under NEAMTWS and also it has provided tsunami scenarios for extended system testing exercises such as NEAMWAVE12. Some of the recent developments at HL-NTWC in Greece include: deployment of new tide gauge stations for tsunami watch purposes, computation of tsunami scenarios and extending the database in use, improving alerting response times, earthquake magnitude estimation and testing newly established software modules for tsunami and earthquake alerting (i.e. Early-Est, SeisComP3 etc.) in Greece and the Eastern Mediterranean. Although funding today is limited, an advantage of the participation in important EC funded research projects, i.e. NERIES, NERA, TRANSFER, NEAMTIC and ASTARTE, demonstrates that collaboration of top class Research Institutions that care to produce important and useful results in the research front in Europe, can facilitate towards developing and operating top class Operational Centers, useful for Civil Protection purposes in regions in need. Last, it is demonstrated that HL-NTWC collaboration with important key role Research Centers in the Security and Safety issues (e

  6. Conceptual Design of a 50--100 MW Electron Beam Accelerator System for the National Hypersonic Wind Tunnel Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SCHNEIDER,LARRY X.

    2000-06-01

    The National Hypersonic Wind Tunnel program requires an unprecedented electron beam source capable of 1--2 MeV at a beam power level of 50--100 MW. Direct-current electron accelerator technology can readily generate high average power beams to approximately 5 MeV at output efficiencies greater than 90%. However, due to the nature of research and industrial applications, there has never been a requirement for a single module with an output power exceeding approximately 500 kW. Although a 50--100 MW module is a two-order extrapolation from demonstrated power levels, the scaling of accelerator components appears reasonable. This paper presents an evaluation of componentmore » and system issues involved in the design of a 50--100 MW electron beam accelerator system with precision beam transport into a high pressure flowing air environment.« less

  7. Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory.

    PubMed

    Weathersby, S P; Brown, G; Centurion, M; Chase, T F; Coffee, R; Corbett, J; Eichner, J P; Frisch, J C; Fry, A R; Gühr, M; Hartmann, N; Hast, C; Hettel, R; Jobe, R K; Jongewaard, E N; Lewandowski, J R; Li, R K; Lindenberg, A M; Makasyuk, I; May, J E; McCormick, D; Nguyen, M N; Reid, A H; Shen, X; Sokolowski-Tinten, K; Vecchione, T; Vetter, S L; Wu, J; Yang, J; Dürr, H A; Wang, X J

    2015-07-01

    Ultrafast electron probes are powerful tools, complementary to x-ray free-electron lasers, used to study structural dynamics in material, chemical, and biological sciences. High brightness, relativistic electron beams with femtosecond pulse duration can resolve details of the dynamic processes on atomic time and length scales. SLAC National Accelerator Laboratory recently launched the Ultrafast Electron Diffraction (UED) and microscopy Initiative aiming at developing the next generation ultrafast electron scattering instruments. As the first stage of the Initiative, a mega-electron-volt (MeV) UED system has been constructed and commissioned to serve ultrafast science experiments and instrumentation development. The system operates at 120-Hz repetition rate with outstanding performance. In this paper, we report on the SLAC MeV UED system and its performance, including the reciprocal space resolution, temporal resolution, and machine stability.

  8. Should money follow the patient: Financial implication for being the National Centre for the Treatment and Management of Pelvic and Acetabular Fractures in Ireland.

    PubMed

    Kelly, M E; Leonard, M; Green, C; Beggs, R; Cheung, C; McElwain, J; Morris, S

    2013-12-01

    Pelvic and acetabular fractures are complex injuries requiring specialist treatment. Our institution is the National Centre for Treatment and Management of these injuries. To audit all referrals to our institution over a 6-month period and calculate the cost incurred by being the national referral centre. Retrospective review of database, and subsequent allocation of Casemix points to assess total cost of treatment for each patient referred to our institution. 103 patients referred with pelvic or acetabular fracture for operative management. The furthest referral distance was 181miles. Over-all, the length of stay was 15.4 days. The average inclusive cost for a referral to our unit for operative management was €16,302. Pelvic and acetabular fractures are complex injuries that require specialist referral unit management. However for these units to remain sustainable money needs to "follow the patient". Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  9. Serbia National Poison Control Centre: organization and current activities.

    PubMed

    Jovanović, Dugan; Joksović, Dragan; Vucinić, Savica; Todorović, Veljko; Segrt, Zoran; Kilibarda, Vesna; Bokonjić, Dubravko

    2005-01-01

    Ministry of Health of the former Federal Republic of Yugoslavia established the National Poison Control Centre in 1995. However, that was only the formally solution since clinical, analytical and experimental services in toxicology had worked independently for at least 40 years. Besides the Headquarters, NPCC has currently 2 main units, the Clinic of Emergency and Clinical Toxicology and Pharmacology and the Institute of Toxicology and Pharmacology. The latter is consisted of Toxicological Information Department, Department of Analytical Toxicology and Department of Experimental Toxicology and Pharmacology. The Mobile Toxicological Chemical Unit is a separate department that is activated from personnel of the NPCC in a case of chemical accidents and/or disasters. Clinical, information and analytical parts of NPCC have a 365-day/24-hour working service. The Clinic of Emergency and Clinical Toxicology and Pharmacology is a place where the intoxicated patients are treated, including those that need the intensive care measures. Toxicological Information Department uses the data from a self-made computer Database for different information purposes. Department of Analytical Toxicology is equipped with a lot of contemporary analytical equipment that is giving the opportunity of identification and quantification of chemicals/metabolites/degradation products in biological material, food, water, air and soil. Basic pharmacological and toxicological research of chemicals and pre-clinical investigations of antidotes are realized in the Department of Experimental Toxicology and Pharmacology. In terms of medical prevention and rational treatment of human poison exposures in Serbia, the current organization of NPCC has so far proven to be effective.

  10. Evaluating the Effectiveness of Information Centres and Services

    DTIC Science & Technology

    1988-09-01

    THE EFFECTIVENESS OF INFORMATION CENTRES AND SERVICES Accession For ZTIS GRA&I DTIC TAB Unarnnounoed 0- Justilfication By Distribution/ Availability...Recommending effective ways for the member nations to use their research and development capabilities for the common benefit of the NATO community; - Providing...evaluation is done. It proposes various strategies for altering the centres and services so that effectiveness is improved; in so doing, it covers

  11. Byurakan Astrophysical Observatory as Cultural Centre

    NASA Astrophysics Data System (ADS)

    Mickaelian, A. M.; Farmanyan, S. V.

    2016-12-01

    NAS RA V. Ambartsumian Byurakan Astrophysical Observatory is presented as a cultural centre for Armenia and the Armenian nation in general. Besides being scientific and educational centre, the Observatory is famous for its unique architectural ensemble, rich botanical garden and world of birds, as well as it is one of the most frequently visited sightseeing of Armenia. In recent years, the Observatory has also taken the initiative of the coordination of the Cultural Astronomy in Armenia and in this field, unites the astronomers, historians, archaeologists, ethnographers, culturologists, literary critics, linguists, art historians and other experts.

  12. The last large pelletron accelerator of the Herb era

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chopra, S.; Narayanan, M. M.; Joshi, R.

    1999-04-26

    Prof. Ray Herb pioneered the concept and design of the tandem Pelletron accelerator in the late sixties at NEC. The 15UD Pelletron at Nuclear Science Centre (NSC), upgraded for 16MV operation using compressed geometry accelerating tubes is the last such large Pelletron. It has unique features like offset and matching quadrupoles after the stripper for charge state selection inside the high voltage terminal and consequently the option of further stripping the ion species of the selected charge states at high energy dead section, and elaborate pulsing system in the pre-acceleration region consisting of a beam chopper, a travelling wave deflector,more » a light ion buncher (1-80 amu) and a heavy ion buncher (>80 amu). NSC was established as a heavy ion accelerator based inter university centre in 1985. It became operational in July 1991 to cater to the research requirements of a large user community which at present includes about fifty universities, twenty-eight colleges and a dozen other academic institutes and research laboratories. The number of users in Materials and allied sciences is about 500. Various important modifications have been made to improve the performance of the accelerator in the last seven years. These include replacement of the corona voltage grading system by a resistor based one, a pick-up loop to monitor charging system performance, conversion from basic double unit structure to singlet, installation of a spiral cavity based phase detector system with post-accelerator stripper after the analyzing magnet, and a high efficiency multi harmonic buncher. Installation of a turbo pump based stripper gas recirculation system in the terminal is also planned. A brief description of utilization of the machine will be given.« less

  13. Using a national archive of patient experience narratives to promote local patient-centered quality improvement: an ethnographic process evaluation of 'accelerated' experience-based co-design.

    PubMed

    Locock, Louise; Robert, Glenn; Boaz, Annette; Vougioukalou, Sonia; Shuldham, Caroline; Fielden, Jonathan; Ziebland, Sue; Gager, Melanie; Tollyfield, Ruth; Pearcey, John

    2014-10-01

    To evaluate an accelerated form of experience-based co-design (EBCD), a type of participatory action research in which patients and staff work together to improve quality; to observe how acceleration affected the process and outcomes of the intervention. An ethnographic process evaluation of an adapted form of EBCD was conducted, including observations, interviews, questionnaires and documentary analysis. Whilst retaining all components of EBCD, the adapted approach replaced local patient interviews with secondary analysis of a national archive of patient experience narratives to create national trigger films; shortened the timeframe; and employed local improvement facilitators. It was tested in intensive care and lung cancer in two English National Health Service (NHS) hospitals. A total of 96 clinical staff (primarily nursing and medical), and 63 patients and family members participated in co-design activities. The accelerated approach proved acceptable to staff and patients; using films of national rather than local narratives did not adversely affect local NHS staff engagement, and may have made the process less threatening or challenging. Local patients felt the national films generally reflected important themes although a minority felt they were more negative than their own experience. However, they served their purpose of 'triggering' discussion between patients and staff, and the resulting 48 co-design (improvement) activities across the four pathways were similar to those in EBCD, but achieved more quickly and at lower cost. Accelerated EBCD offers a rigorous and relatively cost-effective patient-centered quality improvement approach. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Problems and Prospects of Education Resource Centres in Nigeria

    ERIC Educational Resources Information Center

    Ekanem, Johnson Efiong

    2015-01-01

    Nigeria has good policies on Education and one of such policies is the establishment of Education Resource Centres in every State of the Federation, including the Federal Capital Territory, Abuja. The need is clearly articulated in the National Policy on Education. Despite the lofty plan, most of the centres are not fulfilling the need for their…

  15. Vacuum Brazing of Accelerator Components

    NASA Astrophysics Data System (ADS)

    Singh, Rajvir; Pant, K. K.; Lal, Shankar; Yadav, D. P.; Garg, S. R.; Raghuvanshi, V. K.; Mundra, G.

    2012-11-01

    Commonly used materials for accelerator components are those which are vacuum compatible and thermally conductive. Stainless steel, aluminum and copper are common among them. Stainless steel is a poor heat conductor and not very common in use where good thermal conductivity is required. Aluminum and copper and their alloys meet the above requirements and are frequently used for the above purpose. The accelerator components made of aluminum and its alloys using welding process have become a common practice now a days. It is mandatory to use copper and its other grades in RF devices required for accelerators. Beam line and Front End components of the accelerators are fabricated from stainless steel and OFHC copper. Fabrication of components made of copper using welding process is very difficult and in most of the cases it is impossible. Fabrication and joining in such cases is possible using brazing process especially under vacuum and inert gas atmosphere. Several accelerator components have been vacuum brazed for Indus projects at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore using vacuum brazing facility available at RRCAT, Indore. This paper presents details regarding development of the above mentioned high value and strategic components/assemblies. It will include basics required for vacuum brazing, details of vacuum brazing facility, joint design, fixturing of the jobs, selection of filler alloys, optimization of brazing parameters so as to obtain high quality brazed joints, brief description of vacuum brazed accelerator components etc.

  16. Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weathersby, S. P.; Brown, G.; Chase, T. F.

    Ultrafast electron probes are powerful tools, complementary to x-ray free-electron lasers, used to study structural dynamics in material, chemical, and biological sciences. High brightness, relativistic electron beams with femtosecond pulse duration can resolve details of the dynamic processes on atomic time and length scales. SLAC National Accelerator Laboratory recently launched the Ultrafast Electron Diffraction (UED) and microscopy Initiative aiming at developing the next generation ultrafast electron scattering instruments. As the first stage of the Initiative, a mega-electron-volt (MeV) UED system has been constructed and commissioned to serve ultrafast science experiments and instrumentation development. The system operates at 120-Hz repetition ratemore » with outstanding performance. In this paper, we report on the SLAC MeV UED system and its performance, including the reciprocal space resolution, temporal resolution, and machine stability.« less

  17. Particle acceleration at a reconnecting magnetic separator

    NASA Astrophysics Data System (ADS)

    Threlfall, J.; Neukirch, T.; Parnell, C. E.; Eradat Oskoui, S.

    2015-02-01

    Context. While the exact acceleration mechanism of energetic particles during solar flares is (as yet) unknown, magnetic reconnection plays a key role both in the release of stored magnetic energy of the solar corona and the magnetic restructuring during a flare. Recent work has shown that special field lines, called separators, are common sites of reconnection in 3D numerical experiments. To date, 3D separator reconnection sites have received little attention as particle accelerators. Aims: We investigate the effectiveness of separator reconnection as a particle acceleration mechanism for electrons and protons. Methods: We study the particle acceleration using a relativistic guiding-centre particle code in a time-dependent kinematic model of magnetic reconnection at a separator. Results: The effect upon particle behaviour of initial position, pitch angle, and initial kinetic energy are examined in detail, both for specific (single) particle examples and for large distributions of initial conditions. The separator reconnection model contains several free parameters, and we study the effect of changing these parameters upon particle acceleration, in particular in view of the final particle energy ranges that agree with observed energy spectra.

  18. Industry Restructuring: Extracts from Centre Publications.

    ERIC Educational Resources Information Center

    Hall, William C., Ed.

    This document contains excerpts from material previously published by Australia's TAFE (Technical and Further Education) National Centre for Research and Development on the subjects of industry restructuring, the reasons for restructuring, revising curricula, and providing a service to business and industry. Its contents are "Industry…

  19. Multipactor Physics, Acceleration, and Breakdown in Dielectric-Loaded Accelerating Structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, Richard P.; Gold, Steven H.

    2016-07-01

    The objective of this 3-year program is to study the physics issues associated with rf acceleration in dielectric-loaded accelerating (DLA) structures, with a focus on the key issue of multipactor loading, which has been found to cause very significant rf power loss in DLA structures whenever the rf pulsewidth exceeds the multipactor risetime (~10 ns). The experiments are carried out in the X-band magnicon laboratory at the Naval Research Laboratory (NRL) in collaboration with Argonne National Laboratory (ANL) and Euclid Techlabs LLC, who develop the test structures with support from the DoE SBIR program. There are two main elements inmore » the research program: (1) high-power tests of DLA structures using the magnicon output (20 MW @11.4 GHz), and (2) tests of electron acceleration in DLA structures using relativistic electrons from a compact X-band accelerator. The work during this period has focused on a study of the use of an axial magnetic field to suppress multipactor in DLA structures, with several new high power tests carried out at NRL, and on preparation of the accelerator for the electron acceleration experiments.« less

  20. Being prepared to verify the CTBT-Atmospheric Transport modeling and radionuclide analysis at the Austrian National Data Centre during the NDC Preparedness Exercise 2009

    NASA Astrophysics Data System (ADS)

    Wotawa, Gerhard; Schraick, Irene

    2010-05-01

    An explosion in the Kara-Zhyra mine in Eastern Kazakhstan on 28 November 2009 around 07:20 UTC was recorded by both the CTBTO seismic and infrasound networks. This event triggered a world-wide preparedness exercise among the CTBTO National Data Centres. Within an hour after the event was selected by the German NDC, a computer program developed by NDC Austria based on weather forecasts from the European Centre for Medium-Range Weather Forecasts (ECMWF) and from the U.S. National Centers for Environmental Prediction (NCEP) was started to analyse what Radionuclide Stations of the CTBTO International Monitoring System (IMS) would be potentially affected by the release from a nuclear explosion at this place in the course of the following 3-10 days. These calculations were daily updated to consider the observed state of the atmosphere instead of the predicted one. Based on these calculations, automated and reviewed radionuclide reports from the potentially affected stations as produced by the CTBTO International Data Centre (IDC) were looked at. An additional analysis of interesting spectra was provided by the Seibersdorf Laboratories. Based on all the results coming in, no evidence whatsoever was found that the explosion in Kazakhstan was nuclear. This is in accordance with ground truth information saying that the event was caused by the detonation of more than 53 Tons of explosives as part of mining operations. A number of conclusions can be drawn from this exercise. First, the international, bilateral as well as national mechanisms and procedures in place for such an event worked smoothly. Second, the products and services from the CTBTO IDC proved to be very useful to assist the member states in their verification efforts. Last but not least, issues with the availability of data from IMS radionuclide stations do remain.

  1. The use of the super accelerated hepatitis B vaccination regimen in a north London sexual assault referral centre (SARC).

    PubMed

    Ahmed, Syma M; Volpellier, Muriel; Forster, Greta

    2007-02-01

    The super accelerated hepatitis B vaccination regimen was offered to survivors of sexual assault, attending the Haven Paddington, who were at possible risk of contracting the virus [Clinical Effectiveness Group. National Guideline on the Management of Adult Victims of Sexual Assault. Sex Trans Inf 2001;(Suppl. 1):S82-S84]. The uptake and completion rates of the vaccination over two time periods from March 2004 and January 2005 were audited, using 150 clients in each group. More clients accepted the initial vaccination at the time of the forensic medical examination in the second audit when compared with the first [80 clients (73%) and 73 clients (71%), respectively]. Similar numbers of clients completed the course during both study periods [34 clients (47%) and 30 clients (38%), respectively]. Of 65% of clients who had their hepatitis B surface antibody titre checked at three months during the first audit, 77% had protective levels [>10 mIU/ml]. There was little difference following the second audit, where 75% of those who had their antibody checked were found to have protective levels. Our study has shown that this client group accepted the super accelerated hepatitis B vaccination regimen. Early serological response compares well with published data for this vaccination regimen in other settings.

  2. Seismological Investigations of the National Data Centre Preparedness Exercise 2015 (NPE2015)

    NASA Astrophysics Data System (ADS)

    Gestermann, Nicolai; Hartmann, Gernot; Ross, Jens-Ole

    2017-04-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) prohibits all kinds of nuclear explosions. For the detection of treaty violations the International Monitoring System (IMS) operates stations observing seismic, hydroacoustic, and infrasound signals as well as radioisotopes in the atmosphere. While the IMS data is collected, processed and technically analyzed in the International Data Center (IDC) of the CTBT-Organization, National Data Centers (NDC) provide interpretation and advice to their government concerning suspicious detections occurring in IMS data. The National Data Centre Preparedness Exercises (NPE) are regularly performed dealing with fictitious treaty violations to practice the combined analysis of CTBT verification technologies and national technical means. These exercises should help to evaluate the effectiveness of analysis procedures applied at NDCs and the quality, completeness and usefulness of IDC products. The NPE2015 is a combined radionuclide-waveform scenario. Fictitious particulate radionuclide and radioxenon measurements at stations of the IMS (International Monitoring System) of the CTBTO were reported to the international community. The type of isotopes and concentrations could arise from an underground nuclear explosion (UNE). The task of the exercise is to identify the scenario behind the provided data. The source region and time domain of a possible treaty violation activity was determined from ATM in backtracking mode with input data from the fictitious data. A time slot in October and a region around the mining area of Lubin could be identified as the possible source area of the fictitious measurements. The seismicity of the determined source region was investigated in detail to identify events which cannot be classified as natural or induced within the relevant time interval. The comparison of spectral characteristics and a cluster analysis was applied to search for a non-characteristic event within a number of known induced events

  3. Byurakan Astrophysical Observatory as Cultural Centre

    NASA Astrophysics Data System (ADS)

    Mickaelian, A. M.; Farmanyan, S. V.

    2017-07-01

    NAS RA V. Ambartsumian Byurakan Astrophysical Observatory is presented as a cultural centre for Armenia and the Armenian nation in general. Besides being scientific and educational centre, the Observatory is famous for its unique architectural ensemble, rich botanical garden and world of birds, as well as it is one of the most frequently visited sightseeing of Armenia. In recent years, the Observatory has also taken the initiative of the coordination of the Cultural Astronomy in Armenia and in this field, unites the astronomers, historians, archaeologists, ethnographers, culturologists, literary critics, linguists, art historians and other experts. Keywords: Byurakan Astrophysical Observatory, architecture, botanic garden, tourism, Cultural Astronomy.

  4. In Pursuit of a Multi-lateral Dialogue - the Swiss National Centre for Climate Services (NCCS)

    NASA Astrophysics Data System (ADS)

    Michiko Hama, Angela; Croci-Maspoli, Mischa; Liniger, Mark; Schwierz, Cornelia; Stöckli, Reto; Fischer, Andreas; Gubler, Stefanie; Kotlarski, Sven; Rossa, Andrea; Zubler, Elias; Appenzeller, Christof

    2017-04-01

    Kick-starting, fostering and maintaining a dialogue between primarily public and academic actors involved in the co-design, co-delivery and use of climate services is at the core of Switzerland's National Centre for Climate Services (NCCS), which was founded in late 2015 in recognition of the Global Framework for Climate Services (GFCS). This coordination and innovation mechanism is a concerted national effort comprised of seven Federal Agencies and Institutes and further partners from academia committed to implementing the Framework at national to subnational level and creating synergies the world over. The NCCS is to be regarded as vital alongside the Swiss National Adaptation Strategy, and it also contributes to putting words into action with respect to the UN's Sustainable Development Goals, the UNFCCC and the Sendai Framework for Disaster Risk Reduction. The services of the Centre provide information to support policy-makers from national to local level as well as the private sector and society at large in minimising their risks, maximising opportunities and optimising costs in the context of climate change and variability. They are indispensable for setting effective mitigation and adaptation measures and for instigating societal transformation. Hence, the goals of the NCCS are to bundle the existing climate services of the Swiss Federation, co-create new tailored solutions with users, act as a network agent and knowledge broker - to boost climate literacy and enable climate-sensitive decision-making leading to increased resilience. The services reflect the specificities and requirements of the Alpine region and its particular challenges and vulnerabilities. Pursuing a participatory approach, the NCCS has brought together essential key players, acted as a sounding board for governmental stakeholders and their needs, and accordingly defined and populated six priority themes in line with the priority areas of the GFCS. These themes are: natural hazards, health

  5. Reframing the focus from a family-centred to a child-centred care approach for children's healthcare.

    PubMed

    Coyne, Imelda; Hallström, Inger; Söderbäck, Maja

    2016-05-01

    In this article, we argue for a conceptual move from family-centred care (FCC) to a child-centred care approach and the implications for clinical nursing practice. Firstly, we argue that the parents and professional dominance constructs an asymmetric relationship towards the child, which may take away the focus from the child; Secondly, we need to renew efforts to promote the fundamental principles of protection, promotion and participation rights for children and young people according to the United Nations Convention on the Rights of the Child declaration and thirdly, we need to strengthen the child's perspective and to view the child as an agent representing own experiences and wishes to be respected and negotiated. © The Author(s) 2016.

  6. NIH/NSF accelerate biomedical research innovations

    Cancer.gov

    A collaboration between the National Science Foundation and the National Institutes of Health will give NIH-funded researchers training to help them evaluate their scientific discoveries for commercial potential, with the aim of accelerating biomedical in

  7. [Frameless set-up with ExacTrac® system for stereotactic radiotherapy of brain metastasis: Descriptive study from five French centres].

    PubMed

    Ohnleiter, T; Mahé, M-A; Biau, J; Wdowczyk, D; Clavier, J-B; Antoni, D; Noël, G

    2016-12-01

    This study aimed to analyse the positioning protocols with the ExacTrac ® system, associated with a dedicated linear accelerator such as Novalis ® , for stereotactic treatment of brain metastases in several French centres. A survey, including three questions about the prescription of irradiation and twenty-one questions about how the ExacTrac ® system is used, was sent to nine French centres owning a dedicated Novalis ® accelerator. Five centres have accepted to participate in the study. All centres checked the positioning before each treatment's bow, with residual mismatch tolerances of 0.5 to 0.7mm for the translations and 0.5 to 1° for the rotations. All centres except one also realised orthogonal planar images of classic incidences to help operators ensure proper isocentre positioning. Prescribed doses were 20Gy in one fraction, 30Gy and 33Gy in three fractions or 34Gy in four fractions, mainly depending on the size of the lesion. Finally, a physician validated the images at the treatment station before starting the irradiation. The practices of the different centres concerning the positioning protocols were rather homogeneous, in agreement with the literature data on ExacTrac ® system's accuracy, as well as proposed fractionations. The systematic medical validation at the treatment station may, however, be questioned because of the waiting time between the doctor's call and validation itself and because of its usefulness; indeed, corrections by the radiation oncologist are very rare and in some centres, non-existent. Copyright © 2016. Published by Elsevier SAS.

  8. Distribution uniformity of laser-accelerated proton beams

    NASA Astrophysics Data System (ADS)

    Zhu, Jun-Gao; Zhu, Kun; Tao, Li; Xu, Xiao-Han; Lin, Chen; Ma, Wen-Jun; Lu, Hai-Yang; Zhao, Yan-Ying; Lu, Yuan-Rong; Chen, Jia-Er; Yan, Xue-Qing

    2017-09-01

    Compared with conventional accelerators, laser plasma accelerators can generate high energy ions at a greatly reduced scale, due to their TV/m acceleration gradient. A compact laser plasma accelerator (CLAPA) has been built at the Institute of Heavy Ion Physics at Peking University. It will be used for applied research like biological irradiation, astrophysics simulations, etc. A beamline system with multiple quadrupoles and an analyzing magnet for laser-accelerated ions is proposed here. Since laser-accelerated ion beams have broad energy spectra and large angular divergence, the parameters (beam waist position in the Y direction, beam line layout, drift distance, magnet angles etc.) of the beamline system are carefully designed and optimised to obtain a radially symmetric proton distribution at the irradiation platform. Requirements of energy selection and differences in focusing or defocusing in application systems greatly influence the evolution of proton distributions. With optimal parameters, radially symmetric proton distributions can be achieved and protons with different energy spread within ±5% have similar transverse areas at the experiment target. Supported by National Natural Science Foundation of China (11575011, 61631001) and National Grand Instrument Project (2012YQ030142)

  9. Addiction research centres and the nurturing of creativity. Monitoring the European drug situation: the ongoing challenge for the European Monitoring Centre for Drugs and Drug Addiction (EMCDDA).

    PubMed

    Griffiths, Paul; Mounteney, Jane; Lopez, Dominique; Zobel, Frank; Götz, Wolfgang

    2012-02-01

    The European Monitoring Centre for Drugs and Drug Addiction (EMCDDA) is the designated hub for drug-related information in the European Union. The organization's role is to provide the European Union (EU) and its Member States with a factual overview of European drug problems and a common information framework to support the drugs debate. In order to achieve its mission, the EMCDDA coordinates and relies on a network of 30 national monitoring centres, the Reitox National Focal Points. The Centre publishes on a wide range of drug-related topics, across epidemiology, interventions, laws and policies. Every November, the EMCDDA publishes its Annual Report, providing a yearly update on the European drug situation, translated into 23 EU languages. In line with its founding regulation, the EMCDDA has a role acting as an interface between the worlds of science and policy. While not a research centre in the formal sense, the results the Centre generates serve as catalysts for new research questions and help to identify priorities. Current challenges facing the agency include continuing to increase scientific standards while maintaining a strong institutional role, as well as supporting European efforts to identify, share and codify best practice in the drugs field. © 2011 EMCDDA.

  10. From gene to structure: The protein factory of the NBICS Centre of Kurchatov Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyko, K. M.; Lipkin, A. V.; Popov, V. O., E-mail: vpopov@inbi.ras.ru

    2013-05-15

    The Protein Factory was established at the Centre for Nano, Bio, Info, Cognitive, and Social Sciences and Technologies (NBICS Centre) of the National Research Centre 'Kurchatov Institute' in 2010. The Protein Factory, together with the Centre for Synchrotron Radiation and Nanotechnology, promote research on structural biology. This paper presents the technology platforms developed at the Protein Factory and the facilities available for researchers. The main projects currently being performed at the Protein Factory are briefly described.

  11. Addiction research centres and the nurturing of creativity: Centre for Social Research on Alcohol and Drugs (SoRAD), Stockholm University, Sweden.

    PubMed

    Stenius, Kerstin; Ramstedt, Mats; Olsson, Börje

    2010-03-01

    The Centre for Social Research on Alcohol and Drugs (SoRAD) was established as a national research centre and department within the Faculty of Social Science at Stockholm University in 1997, following a Government Report and with the aim to strengthen social alcohol and drug research. Initially, core funding came from the Swedish Council for Working Life and Social Research and from the Ministry of Health and Social Affairs for several long-term projects. Today, SoRAD, with 25 senior and junior researchers, has core funding from the university but most of its funding comes from external national and international grants. Research is organized under three themes: consumption, problems and norms, alcohol and drug policy and societal reactions, treatment and recovery processes. SoRADs scientific approach, multi-disciplinarity, a mix of qualitative and quantitative methods and international comparisons was established by the centre's first leader, Robin Room. Regular internal seminars are held and young researchers are encouraged to attend scientific meetings and take part in collaborative projects. SoRAD researchers produce government-funded monthly statistics on alcohol consumption and purchase, and take part in various national government committees, but SoRADs research has no clear political or bureaucratic constraints. One of the future challenges for SoRAD will be the proposed system for university grants allocation, where applied social science will have difficulties competing with basic biomedical research if decisions are based on publication and citation measures.

  12. When Triple Helix Unravels: A Multi-Case Analysis of Failures in Industry-University Cooperative Research Centres

    ERIC Educational Resources Information Center

    Gray, Denis; Sundstrom, Eric; Tornatzky, Louis G.; McGowen, Lindsey

    2011-01-01

    Cooperative research centres (CRCs) increasingly foster Triple Helix (industry-university-government) collaboration and represent significant vehicles for cooperation across sectors, the promotion of knowledge and technology transfer and ultimately the acceleration of innovation. A growing social science literature on CRCs focuses on their…

  13. UK National Data Centre archive of seismic recordings of (presumed) underground nuclear tests 1964-1996

    NASA Astrophysics Data System (ADS)

    Young, John; Peacock, Sheila

    2016-04-01

    The year 1996 has particular significance for forensic seismologists. This was the year when the Comprehensive Test Ban Treaty (CTBT) was signed in September at the United Nations, setting an international norm against nuclear testing. Blacknest, as a long time seismic centre for research into detecting and identifying underground explosions using seismology, provided significant technical advice during the CTBT negotiations. Since 1962 seismic recordings of both presumed nuclear explosions and earthquakes from the four seismometer arrays Eskdalemuir, Scotland (EKA), Yellowknife, Canada (YKA), Gauribidanur, India (GBA), and Warramunga, Australia (WRA) have been copied, digitised, and saved. There was a possibility this archive would be lost. It was decided to process the records and catalogue them for distribution to other groups and institutions. This work continues at Blacknest but the archive is no longer under threat. In addition much of the archive of analogue tape recordings has been re-digitised with modern equipment, allowing sampling rates of 100 rather than 20 Hz.

  14. Missed Opportunities to Keep Children Safe? National Survey of Injury Prevention Activities of Children's Centres

    ERIC Educational Resources Information Center

    Watson, Michael Craig; Mulvaney, Caroline; Timblin, Clare; Stewart, Jane; Coupland, Carol A.; Deave, Toity; Hayes, Mike; Kendrick, Denise

    2016-01-01

    Objective: To ascertain the activities undertaken by children's centres to prevent unintentional injuries in the under-fives and, in particular, the prevention of falls, poisoning and scalds. Design: A questionnaire was posted to managers of 851 children's centres, using stratified cluster sampling. The questionnaire included questions on injury…

  15. The epidemiology and type of medication errors reported to the National Poisons Information Centre of Ireland.

    PubMed

    Cassidy, Nicola; Duggan, Edel; Williams, David J P; Tracey, Joseph A

    2011-07-01

    Medication errors are widely reported for hospitalised patients, but limited data are available for medication errors that occur in community-based and clinical settings. Epidemiological data from poisons information centres enable characterisation of trends in medication errors occurring across the healthcare spectrum. The objective of this study was to characterise the epidemiology and type of medication errors reported to the National Poisons Information Centre (NPIC) of Ireland. A 3-year prospective study on medication errors reported to the NPIC was conducted from 1 January 2007 to 31 December 2009 inclusive. Data on patient demographics, enquiry source, location, pharmaceutical agent(s), type of medication error, and treatment advice were collated from standardised call report forms. Medication errors were categorised as (i) prescribing error (i.e. physician error), (ii) dispensing error (i.e. pharmacy error), and (iii) administration error involving the wrong medication, the wrong dose, wrong route, or the wrong time. Medication errors were reported for 2348 individuals, representing 9.56% of total enquiries to the NPIC over 3 years. In total, 1220 children and adolescents under 18 years of age and 1128 adults (≥ 18 years old) experienced a medication error. The majority of enquiries were received from healthcare professionals, but members of the public accounted for 31.3% (n = 736) of enquiries. Most medication errors occurred in a domestic setting (n = 2135), but a small number occurred in healthcare facilities: nursing homes (n = 110, 4.68%), hospitals (n = 53, 2.26%), and general practitioner surgeries (n = 32, 1.36%). In children, medication errors with non-prescription pharmaceuticals predominated (n = 722) and anti-pyretics and non-opioid analgesics, anti-bacterials, and cough and cold preparations were the main pharmaceutical classes involved. Medication errors with prescription medication predominated for adults (n = 866) and the major medication

  16. Accelerated Testing and Analysis | Photovoltaic Research | NREL

    Science.gov Websites

    & Engineering pages: Real-Time PV & Solar Resource Testing Systems Engineering Systems PV standards. Each year, NCPV researchers, along with solar companies and other national lab Accelerated Testing and Analysis Accelerated Testing and Analysis PV Research Other Reliability

  17. Accelerant-related burns and drug abuse: Challenging combination.

    PubMed

    Leung, Leslie T F; Papp, Anthony

    2018-05-01

    Accelerants are flammable substances that may cause explosion when added to existing fires. The relationships between drug abuse and accelerant-related burns are not well elucidated in the literature. Of these burns, a portion is related to drug manufacturing, which have been shown to be associated with increased burn complications. 1) To evaluate the demographics and clinical outcomes of accelerant-related burns in a Provincial Burn Centre. 2) To compare the clinical outcomes with a control group of non-accelerant related burns. 3) To analyze a subgroup of patients with history of drug abuse and drug manufacturing. Retrospective case control study. Patient data associated with accelerant-related burns from 2009 to 2014 were obtained from the British Columbia Burn Registry. These patients were compared with a control group of non-accelerant related burns. Clinical outcomes that were evaluated include inhalational injury, ICU length of stay, ventilator support, surgeries needed, and burn complications. Chi-square test was used to evaluate categorical data and Student's t-test was used to evaluate mean quantitative data with the p value set at 0.05. A logistic regression model was used to evaluate factors affecting burn complications. Accelerant-related burns represented 28.2% of all burn admissions (N=532) from 2009 to 2014. The accelerant group had higher percentage of patients with history of drug abuse and was associated with higher TBSA burns, ventilator support, ICU stay and pneumonia rates compared to the non-accelerant group. Within the accelerant group, there was no difference in clinical outcomes amongst people with or without history of drug abuse. Four cases were associated with methamphetamine manufacturing, all of which underwent ICU stay and ventilator support. Accelerant-related burns cause significant burden to the burn center. A significant proportion of these patients have history of drug abuse. Copyright © 2017 Elsevier Ltd and ISBI. All rights

  18. Testing of a Plasmadynamic Hypervelocity Dust Accelerator

    NASA Astrophysics Data System (ADS)

    Ticos, Catalin M.; Wang, Zhehui; Dorf, Leonid A.; Wurden, G. A.

    2006-10-01

    A plasmadynamic accelerator for microparticles (or dust grains) has been designed, built and tested at Los Alamos National laboratory. The dust grains are expected to be accelerated to hypervelocities on the order of 1-30 km/s, depending on their size. The key components of the plasmadynamic accelerator are a coaxial plasma gun operated at 10 kV, a dust dispenser activated by a piezoelectric transducer, and power and remote-control systems. The coaxial plasma gun produces a high density (10^18 cm-3) and low temperature (˜ 1 eV) plasma in deuterium ejected by J x B forces, which provides drag on the dust particles in its path. Carbon dust particles will be used, with diameters from 1 to 50 μm. The plasma parameters produced in the coaxial gun are presented and their implication to dust acceleration is discussed. High speed dust will be injected in the National Spherical Torus Experiment to measure the pitch angle of magnetic field lines.

  19. Marshak Lectureship: The Turkish Accelerator Center, TAC

    NASA Astrophysics Data System (ADS)

    Yavas, Omer

    2012-02-01

    The Turkish Accelerator Center (TAC) project is comprised of five different electron and proton accelerator complexes, to be built over 15 years, with a phased approach. The Turkish Government funds the project. Currently there are 23 Universities in Turkey associated with the TAC project. The current funded project, which is to run until 2013 aims *To establish a superconducting linac based infra-red free electron laser and Bremsstrahlung Facility (TARLA) at the Golbasi Campus of Ankara University, *To establish the Institute of Accelerator Technologies in Ankara University, and *To complete the Technical Design Report of TAC. The proposed facilities are a 3^rd generation Synchrotron Radiation facility, SASE-FEL facility, a GeV scale Proton Accelerator facility and an electron-positron collider as a super charm factory. In this talk, an overview on the general status and road map of TAC project will be given. National and regional importance of TAC will be expressed and the structure of national and internatonal collaborations will be explained.

  20. The United States Particle Accelerator School: Educating the Next Generation of Accelerator Scientists and Engineers

    NASA Astrophysics Data System (ADS)

    Barletta, William A.

    2009-03-01

    Only a handful of universities in the US offer any formal training in accelerator science. The United States Particle Accelerator School (USPAS) is National Graduate Educational Program that has developed a highly successful educational paradigm that, over the past twenty-years, has granted more university credit in accelerator/beam science and technology than any university in the world. Sessions are held twice annually, hosted by major US research universities that approve course credit, certify the USPAS faculty, and grant course credit. The USPAS paradigm is readily extensible to other rapidly developing, cross-disciplinary research areas such as high energy density physics.

  1. ATOM - Accelerating Therapeutics for Opportunities in Medicine | FNLCR Staging

    Cancer.gov

    The Frederick National Lab is a founding member of the Accelerating Therapeutics for Opportunities in Medicine (ATOM) Consortium,a public-private partnership with themission oftransforming drug discovery by accelerating the deve

  2. Proceedings of: 2005 Particle Acceleration Confence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, Stuart

    2006-01-01

    The 21st Particle Accelerator Conference, PAC05, took place at the Knoxville Convention Center (KCC) from Monday through Friday, May 16-20, 2005. Sponsored by the American Physical Society (APS), the Institute of Electrics and Electronics Engineers (IEEE) with its subdivision of Nuclear and Plasma Sciences Society (NPSS), the conference was hosted by the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Project and Thomas Jefferson National Accelerator Facility (JLab). The conference was chaired by Norbert Holtkamp, and the Local Organizing Committee was made up of staff from the ORNL SNS Project under the chairmanship of Stuart Henderson. The conference welcomedmore » over 1400 delegates from the United States, Europe, Asia, the Middle East, South America and from as far away as Australia. Almost 1400 papers where processed during the conference and will be published on the Joint Accelerator Conferences Website (JACoW) page.« less

  3. Development and implementation of a nurse-led walk-in centre: evidence lost in translation?

    PubMed

    Desborough, Jane; Parker, Rhian; Forrest, Laura

    2013-07-01

    The design of the first Australian public nurse-led primary care walk-in centre was modelled on those established in the English National Health Service (NHS). An independent evaluation of the first 12 months of operation of the Australian Capital Territory (ACT) Health walk-in centre, in 2011, analysed the translation of evidence from the national evaluation of the NHS walk-in centres to the policy development and implementation of the ACT walk-in centre. Whilst in a number of ways the evidence was used well, our interest for this paper was to examine three areas identified as problematic and to identify the points at which the evidence was lost or diluted. In addition to data obtained through nurse and key stakeholder interviews for the evaluation, an analysis was undertaken of documents on the planning and establishment of the ACT walk-in centre, either provided to the evaluation team or made publicly available. Three areas were identified as problematic in the way that evidence from the NHS evaluation was translated: the use of clinical decision support software (CDSS); the marketing of the walk-in centre; and its location. Our examination indicates that despite seeking evidence to inform the development of the ACT walk-in centre, the evidence was not fully used and some clear lessons ignored, resulting in much of the evidence being lost in translation.

  4. Computational Accelerator Physics. Proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, J.J.; Mondelli, A.A.

    1997-04-01

    The sixty two papers appearing in this volume were presented at CAP96, the Computational Accelerator Physics Conference held in Williamsburg, Virginia from September 24{minus}27,1996. Science Applications International Corporation (SAIC) and the Thomas Jefferson National Accelerator Facility (Jefferson lab) jointly hosted CAP96, with financial support from the U.S. department of Energy`s Office of Energy Research and the Office of Naval reasearch. Topics ranged from descriptions of specific codes to advanced computing techniques and numerical methods. Update talks were presented on nearly all of the accelerator community`s major electromagnetic and particle tracking codes. Among all papers, thirty of them are abstracted formore » the Energy Science and Technology database.(AIP)« less

  5. The Spallation Neutron Source accelerator system design

    NASA Astrophysics Data System (ADS)

    Henderson, S.; Abraham, W.; Aleksandrov, A.; Allen, C.; Alonso, J.; Anderson, D.; Arenius, D.; Arthur, T.; Assadi, S.; Ayers, J.; Bach, P.; Badea, V.; Battle, R.; Beebe-Wang, J.; Bergmann, B.; Bernardin, J.; Bhatia, T.; Billen, J.; Birke, T.; Bjorklund, E.; Blaskiewicz, M.; Blind, B.; Blokland, W.; Bookwalter, V.; Borovina, D.; Bowling, S.; Bradley, J.; Brantley, C.; Brennan, J.; Brodowski, J.; Brown, S.; Brown, R.; Bruce, D.; Bultman, N.; Cameron, P.; Campisi, I.; Casagrande, F.; Catalan-Lasheras, N.; Champion, M.; Champion, M.; Chen, Z.; Cheng, D.; Cho, Y.; Christensen, K.; Chu, C.; Cleaves, J.; Connolly, R.; Cote, T.; Cousineau, S.; Crandall, K.; Creel, J.; Crofford, M.; Cull, P.; Cutler, R.; Dabney, R.; Dalesio, L.; Daly, E.; Damm, R.; Danilov, V.; Davino, D.; Davis, K.; Dawson, C.; Day, L.; Deibele, C.; Delayen, J.; DeLong, J.; Demello, A.; DeVan, W.; Digennaro, R.; Dixon, K.; Dodson, G.; Doleans, M.; Doolittle, L.; Doss, J.; Drury, M.; Elliot, T.; Ellis, S.; Error, J.; Fazekas, J.; Fedotov, A.; Feng, P.; Fischer, J.; Fox, W.; Fuja, R.; Funk, W.; Galambos, J.; Ganni, V.; Garnett, R.; Geng, X.; Gentzlinger, R.; Giannella, M.; Gibson, P.; Gillis, R.; Gioia, J.; Gordon, J.; Gough, R.; Greer, J.; Gregory, W.; Gribble, R.; Grice, W.; Gurd, D.; Gurd, P.; Guthrie, A.; Hahn, H.; Hardek, T.; Hardekopf, R.; Harrison, J.; Hatfield, D.; He, P.; Hechler, M.; Heistermann, F.; Helus, S.; Hiatt, T.; Hicks, S.; Hill, J.; Hill, J.; Hoff, L.; Hoff, M.; Hogan, J.; Holding, M.; Holik, P.; Holmes, J.; Holtkamp, N.; Hovater, C.; Howell, M.; Hseuh, H.; Huhn, A.; Hunter, T.; Ilg, T.; Jackson, J.; Jain, A.; Jason, A.; Jeon, D.; Johnson, G.; Jones, A.; Joseph, S.; Justice, A.; Kang, Y.; Kasemir, K.; Keller, R.; Kersevan, R.; Kerstiens, D.; Kesselman, M.; Kim, S.; Kneisel, P.; Kravchuk, L.; Kuneli, T.; Kurennoy, S.; Kustom, R.; Kwon, S.; Ladd, P.; Lambiase, R.; Lee, Y. Y.; Leitner, M.; Leung, K.-N.; Lewis, S.; Liaw, C.; Lionberger, C.; Lo, C. C.; Long, C.; Ludewig, H.; Ludvig, J.; Luft, P.; Lynch, M.; Ma, H.; MacGill, R.; Macha, K.; Madre, B.; Mahler, G.; Mahoney, K.; Maines, J.; Mammosser, J.; Mann, T.; Marneris, I.; Marroquin, P.; Martineau, R.; Matsumoto, K.; McCarthy, M.; McChesney, C.; McGahern, W.; McGehee, P.; Meng, W.; Merz, B.; Meyer, R.; Meyer, R.; Miller, B.; Mitchell, R.; Mize, J.; Monroy, M.; Munro, J.; Murdoch, G.; Musson, J.; Nath, S.; Nelson, R.; Nelson, R.; O`Hara, J.; Olsen, D.; Oren, W.; Oshatz, D.; Owens, T.; Pai, C.; Papaphilippou, I.; Patterson, N.; Patterson, J.; Pearson, C.; Pelaia, T.; Pieck, M.; Piller, C.; Plawski, T.; Plum, M.; Pogge, J.; Power, J.; Powers, T.; Preble, J.; Prokop, M.; Pruyn, J.; Purcell, D.; Rank, J.; Raparia, D.; Ratti, A.; Reass, W.; Reece, K.; Rees, D.; Regan, A.; Regis, M.; Reijonen, J.; Rej, D.; Richards, D.; Richied, D.; Rode, C.; Rodriguez, W.; Rodriguez, M.; Rohlev, A.; Rose, C.; Roseberry, T.; Rowton, L.; Roybal, W.; Rust, K.; Salazer, G.; Sandberg, J.; Saunders, J.; Schenkel, T.; Schneider, W.; Schrage, D.; Schubert, J.; Severino, F.; Shafer, R.; Shea, T.; Shishlo, A.; Shoaee, H.; Sibley, C.; Sims, J.; Smee, S.; Smith, J.; Smith, K.; Spitz, R.; Staples, J.; Stein, P.; Stettler, M.; Stirbet, M.; Stockli, M.; Stone, W.; Stout, D.; Stovall, J.; Strelo, W.; Strong, H.; Sundelin, R.; Syversrud, D.; Szajbler, M.; Takeda, H.; Tallerico, P.; Tang, J.; Tanke, E.; Tepikian, S.; Thomae, R.; Thompson, D.; Thomson, D.; Thuot, M.; Treml, C.; Tsoupas, N.; Tuozzolo, J.; Tuzel, W.; Vassioutchenko, A.; Virostek, S.; Wallig, J.; Wanderer, P.; Wang, Y.; Wang, J. G.; Wangler, T.; Warren, D.; Wei, J.; Weiss, D.; Welton, R.; Weng, J.; Weng, W.-T.; Wezensky, M.; White, M.; Whitlatch, T.; Williams, D.; Williams, E.; Wilson, K.; Wiseman, M.; Wood, R.; Wright, P.; Wu, A.; Ybarrolaza, N.; Young, K.; Young, L.; Yourd, R.; Zachoszcz, A.; Zaltsman, A.; Zhang, S.; Zhang, W.; Zhang, Y.; Zhukov, A.

    2014-11-01

    The Spallation Neutron Source (SNS) was designed and constructed by a collaboration of six U.S. Department of Energy national laboratories. The SNS accelerator system consists of a 1 GeV linear accelerator and an accumulator ring providing 1.4 MW of proton beam power in microsecond-long beam pulses to a liquid mercury target for neutron production. The accelerator complex consists of a front-end negative hydrogen-ion injector system, an 87 MeV drift tube linear accelerator, a 186 MeV side-coupled linear accelerator, a 1 GeV superconducting linear accelerator, a 248-m circumference accumulator ring and associated beam transport lines. The accelerator complex is supported by ~100 high-power RF power systems, a 2 K cryogenic plant, ~400 DC and pulsed power supply systems, ~400 beam diagnostic devices and a distributed control system handling ~100,000 I/O signals. The beam dynamics design of the SNS accelerator is presented, as is the engineering design of the major accelerator subsystems.

  6. Studies of industrial emissions by accelerator-based techniques: A review of applications at CEDAD

    NASA Astrophysics Data System (ADS)

    Calcagnile, L.; Quarta, G.

    2012-04-01

    Different research activities are in progress at the Centre for Dating and Diagnostics (CEDAD), University of Salento, in the field of environmental monitoring by exploiting the potentialities given by the different experimental beam lines implemented on the 3 MV Tande-tron accelerator and dedicated to AMS (Accelerator Mass Spectrome-try) radiocarbon dating and IB A (Ion Beam Analysis). An overview of these activities is presented by showing how accelerator-based analytical techniques can be a powerful tool for monitoring the anthropogenic carbon dioxide emissions from industrial sources and for the assessment of the biogenic content in SRF (Solid Recovered Fuel) burned in WTE (Waste to Energy) plants.

  7. National health expenditure projections: modest annual growth until coverage expands and economic growth accelerates.

    PubMed

    Keehan, Sean P; Cuckler, Gigi A; Sisko, Andrea M; Madison, Andrew J; Smith, Sheila D; Lizonitz, Joseph M; Poisal, John A; Wolfe, Christian J

    2012-07-01

    For 2011-13, US health spending is projected to grow at 4.0 percent, on average--slightly above the historically low growth rate of 3.8 percent in 2009. Preliminary data suggest that growth in consumers' use of health services remained slow in 2011, and this pattern is expected to continue this year and next. In 2014, health spending growth is expected to accelerate to 7.4 percent as the major coverage expansions from the Affordable Care Act begin. For 2011 through 2021, national health spending is projected to grow at an average rate of 5.7 percent annually, which would be 0.9 percentage point faster than the expected annual increase in the gross domestic product during this period. By 2021, federal, state, and local government health care spending is projected to be nearly 50 percent of national health expenditures, up from 46 percent in 2011, with federal spending accounting for about two-thirds of the total government share. Rising government spending on health care is expected to be driven by faster growth in Medicare enrollment, expanded Medicaid coverage, and the introduction of premium and cost-sharing subsidies for health insurance exchange plans.

  8. The changing interface between district hospital cardiology and the major cardiac centres

    PubMed Central

    1997-01-01

    The national priority for reducing mortality and morbidity from cardiovascular disease, the resulting expansion in the number of consultant cardiologists, and the reforms of the National Health Service have produced significant changes in delivery of care for cardiac patients and in the relations between district general hospitals (DGH) and the old regional cardiac centres. 1.2 The British Cardiac Society, the Medical Royal Colleges of Physicians of London and Edinburgh, and the Royal College of Physicians and Surgeons of Glasgow established a working group to make recommendations on the most appropriate evolution of these changes to secure high quality care in a cost-effective and professionally rewarding environment. The principal conclusions of the working group were: i) The establishment of new cardiac catheterisation laboratories in DGHs remote from a major cardiac centre should be encouraged provided the workload is adequate to ensure efficient use of the facility. ii) Cardiologists working in districts close to a major centre should be encouraged to catheterise their patients at the centre. iii) Close liaison of the district cardiologist with a cardiac surgeon and interventionist is vitally important. iv) The centres will be required to provide tertiary care for emergency and urgent cases from their traditional catchment area, specialised expertise for the management of rare and difficult cases, and angioplasty. Some centres will also offer complex electrophysiology, and ablation techniques. v) The centres must also provide routine cardiology services for their local district, facilities for cardiac catheterisation for DGH cardiologists, and training for doctors, nurses, technicians, and radiographers. vi) Some centres will be linked with paediatric cardiology and paediatric cardiac surgical units. vii) District cardiac centres will be required to provide a full non-invasive diagnostic service and emergency care for patients referred by general practitioners

  9. Particle acceleration on a chip: A laser-driven micro-accelerator for research and industry

    NASA Astrophysics Data System (ADS)

    Yoder, R. B.; Travish, G.

    2013-03-01

    Particle accelerators are conventionally built from radio-frequency metal cavities, but this technology limits the maximum energy available and prevents miniaturization. In the past decade, laser-powered acceleration has been intensively studied as an alternative technology promising much higher accelerating fields in a smaller footprint and taking advantage of recent advances in photonics. Among the more promising approaches are those based on dielectric field-shaping structures. These ``dielectric laser accelerators'' (DLAs) scale with the laser wavelength employed and can be many orders of magnitude smaller than conventional accelerators; DLAs may enable the production of high-intensity, ultra-short relativistic electron bunches in a chip-scale device. When combined with a high- Z target or an optical-period undulator, these systems could produce high-brilliance x-rays from a breadbox-sized device having multiple applications in imaging, medicine, and homeland security. In our research program we have developed one such DLA, the Micro-Accelerator Platform (MAP). We describe the fundamental physics, our fabrication and testing program, and experimental results to date, along with future prospects for MAP-based light-sources and some remaining challenges. Supported in part by the Defense Threat Reduction Agency and National Nuclear Security Administration.

  10. Direct Laser Acceleration in Laser Wakefield Accelerators

    NASA Astrophysics Data System (ADS)

    Shaw, J. L.; Froula, D. H.; Marsh, K. A.; Joshi, C.; Lemos, N.

    2017-10-01

    The direct laser acceleration (DLA) of electrons in a laser wakefield accelerator (LWFA) has been investigated. We show that when there is a significant overlap between the drive laser and the trapped electrons in a LWFA cavity, the accelerating electrons can gain energy from the DLA mechanism in addition to LWFA. The properties of the electron beams produced in a LWFA, where the electrons are injected by ionization injection, have been investigated using particle-in-cell (PIC) code simulations. Particle tracking was used to demonstrate the presence of DLA in LWFA. Further PIC simulations comparing LWFA with and without DLA show that the presence of DLA can lead to electron beams that have maximum energies that exceed the estimates given by the theory for the ideal blowout regime. The magnitude of the contribution of DLA to the energy gained by the electron was found to be on the order of the LWFA contribution. The presence of DLA in a LWFA can also lead to enhanced betatron oscillation amplitudes and increased divergence in the direction of the laser polarization. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  11. Centre for Research Infrastructure of Polish GNSS Data - response and possible contribution to EPOS

    NASA Astrophysics Data System (ADS)

    Araszkiewicz, Andrzej; Rohm, Witold; Bosy, Jaroslaw; Szolucha, Marcin; Kaplon, Jan; Kroszczynski, Krzysztof

    2017-04-01

    In the frame of the first call under Action 4.2: Development of modern research infrastructure of the science sector in the Smart Growth Operational Programme 2014-2020 in the late of 2016 the "EPOS-PL" project has launched. Following institutes are responsible for the implementation of this project: Institute of Geophysics, Polish Academy of Sciences - Project Leader, Academic Computer Centre Cyfronet AGH University of Science and Technology, Central Mining Institute, the Institute of Geodesy and Cartography, Wrocław University of Environmental and Life Sciences, Military University of Technology. In addition, resources constituting entrepreneur's own contribution will come from the Polish Mining Group. Research Infrastructure EPOS-PL will integrate both existing and newly built National Research Infrastructures (Theme Centre for Research Infrastructures), which, under the premise of the program EPOS, are financed exclusively by the national founds. In addition, the e-science platform will be developed. The Centre for Research Infrastructure of GNSS Data (CIBDG - Task 5) will be built based on the experience and facilities of two institutions: Military University of Technology and Wrocław University of Environmental and Life Sciences. The project includes the construction of the National GNNS Repository with data QC procedures and adaptation of two Regional GNNS Analysis Centres for rapid and long-term geodynamical monitoring.

  12. Accelerated Math[TM]. What Works Clearinghouse Intervention Report

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2011

    2011-01-01

    "Accelerated Math"[TM], published by Renaissance Learning, is a software tool used to customize assignments and monitor progress in math for students in grades 1-12. The "Accelerated Math"[TM] software creates individualized assignments aligned with state standards and national guidelines, scores student work, and generates…

  13. Changing epidemiology of AA amyloidosis: clinical observations over 25 years at a single national referral centre.

    PubMed

    Lane, Thirusha; Pinney, Jennifer H; Gilbertson, Janet A; Hutt, David F; Rowczenio, Dorota M; Mahmood, Shameem; Sachchithanantham, Sajitha; Fontana, Marianna; Youngstein, Taryn; Quarta, Candida C; Wechalekar, Ashutosh D; Gillmore, Julian D; Hawkins, Philip N; Lachmann, Helen J

    2017-09-01

    Systemic AA amyloidosis is a serious complication of chronic inflammation; however, there are relatively few published data on its incidence. We investigated the changing epidemiology of AA amyloidosis over a 25-year period at a single national referral centre. We conducted a retrospective study of all patients diagnosed with AA amyloidosis who had attended the centre between 1990 and 2014 inclusive. Six hundred and twenty-five patients were studied in three cohorts: C1: 1990-1997; C2: 1998-2006; C3: 2007-2014. Mean age at presentation increased from 46 in C1 to 56 in C3 (p < .0001). The proportion of South Asian patients increased from 4% in C1 to 17% in C3 (p = .0006). Comparison of underlying diseases between C1 and C3 revealed a reduction in patients with juvenile idiopathic arthritis from 25% to 2% (p < .0001), but an increase in patients with chronic infection due to intravenous recreational drug use from 1% to 13% (p < .0001), and uncharacterized inflammatory disorders from 10% to 27% (p <.0001). More patients were in end-stage renal failure at presentation in C3 (29%) than C1 (15%) (p = .0028). Median age at death was later in C3 (62 years) than C1 (54 years) (p = .0012). These data suggest both falling incidence and better outcome in AA amyloidosis over a quarter of a century, reflecting advances in therapeutics and overall management of complex chronic disease in an ageing population. AA amyloidosis of uncertain aetiology presents an emerging major problem. Newer techniques such as next-generation sequencing may aid diagnosis and effective treatment, thereby improving overall survival.

  14. An instability of the standard model of cosmology creates the anomalous acceleration without dark energy

    NASA Astrophysics Data System (ADS)

    Smoller, Joel; Temple, Blake; Vogler, Zeke

    2017-11-01

    We identify the condition for smoothness at the centre of spherically symmetric solutions of Einstein's original equations without the cosmological constant or dark energy. We use this to derive a universal phase portrait which describes general, smooth, spherically symmetric solutions near the centre of symmetry when the pressure p=0. In this phase portrait, the critical k=0 Friedmann space-time appears as a saddle rest point which is unstable to spherical perturbations. This raises the question as to whether the Friedmann space-time is observable by redshift versus luminosity measurements looking outwards from any point. The unstable manifold of the saddle rest point corresponding to Friedmann describes the evolution of local uniformly expanding space-times whose accelerations closely mimic the effects of dark energy. A unique simple wave perturbation from the radiation epoch is shown to trigger the instability, match the accelerations of dark energy up to second order and distinguish the theory from dark energy at third order. In this sense, anomalous accelerations are not only consistent with Einstein's original theory of general relativity, but are a prediction of it without the cosmological constant or dark energy.

  15. An instability of the standard model of cosmology creates the anomalous acceleration without dark energy.

    PubMed

    Smoller, Joel; Temple, Blake; Vogler, Zeke

    2017-11-01

    We identify the condition for smoothness at the centre of spherically symmetric solutions of Einstein's original equations without the cosmological constant or dark energy. We use this to derive a universal phase portrait which describes general, smooth, spherically symmetric solutions near the centre of symmetry when the pressure p =0. In this phase portrait, the critical k =0 Friedmann space-time appears as a saddle rest point which is unstable to spherical perturbations. This raises the question as to whether the Friedmann space-time is observable by redshift versus luminosity measurements looking outwards from any point. The unstable manifold of the saddle rest point corresponding to Friedmann describes the evolution of local uniformly expanding space-times whose accelerations closely mimic the effects of dark energy. A unique simple wave perturbation from the radiation epoch is shown to trigger the instability, match the accelerations of dark energy up to second order and distinguish the theory from dark energy at third order. In this sense, anomalous accelerations are not only consistent with Einstein's original theory of general relativity, but are a prediction of it without the cosmological constant or dark energy.

  16. Cooperative Research Centres: The Concept and Its Implementation.

    ERIC Educational Resources Information Center

    Slatyer, Ralph O.

    1994-01-01

    Australia's Cooperative Research Centres Program, a system of 52 research and development (R&D) units, links researchers from public and private sectors, helping industry and scientific community coordinate research efforts. The program represents 6% of the national R&D effort and spans six major R&D and industry sectors. (MSE)

  17. The Role of National Adult Education Centre in Curriculum Development in Somalia in Selected Government Primary Adult Schools of Mogadisho. African Studies in Curriculum Development and Evaluation, No. 109.

    ERIC Educational Resources Information Center

    Bahar, Ismail F. S.

    A study of curriculum development in Somalia focused on the role of the National Adult Education Centre (NAEC) and involvement of teachers and inspectors. The sample consisted of 80 Mogadisho primary adult school teachers. Information sources were related literature, teacher questionnaires, and unstructured interviews with school inspectors,…

  18. National cyclotron centre at the Institute for Nuclear Research and Nuclear Energy

    NASA Astrophysics Data System (ADS)

    Tonev, D.; Goutev, N.; Asova, G.; Artinyan, A.; Demerdjiev, A.; Georgiev, L. S.; Yavahchova, M.; Bashev, V.; Genchev, S. G.; Geleva, E.; Mincheva, M.; Nikolov, A.; Dimitrov, D. T.

    2018-05-01

    An accelerator laboratory is presently under construction in Sofia at the Institute for Nuclear Research and Nuclear Energy. The laboratory will use a TR24 type of cyclotron, which provides a possibility to accelerate a proton beam with an energy of 15 to 24 MeV and current of up to 0.4 mA. An accelerator with such parameters allows to produce a large variety of radioisotopes for development of radiopharmaceuticals. The most common radioisotopes that can be produced with such a cyclotron are PET isotopes like: 11C, 13N, 15O, 18F, 124I, 64Cu, 68Ge/68Ga, and SPECT isotopes like: 123I, 111In, 67Ga, 57Co, 99mTc. Our aim is to use the cyclotron facility for research in the fields of radiopharmacy, radiochemistry, radiobiology, nuclear physics, materials sciences, applied research, new materials and for education in all these fields including nuclear energy. Presently we perform investigations in the fields of target design for production of radioisotopes, shielding and radioprotection, new ion sources etc.

  19. A knowledge translation project on community-centred approaches in public health.

    PubMed

    Stansfield, J; South, J

    2018-03-01

    This article examines the development and impact of a national knowledge translation project aimed at improving access to evidence and learning on community-centred approaches for health and wellbeing. Structural changes in the English health system meant that knowledge on community engagement was becoming lost and a fragmented evidence base was seen to impact negatively on policy and practice. A partnership started between Public Health England, NHS England and Leeds Beckett University in 2014 to address these issues. Following a literature review and stakeholder consultation, evidence was published in a national guide to community-centred approaches. This was followed by a programme of work to translate the evidence into national strategy and local practice.The article outlines the key features of the knowledge translation framework developed. Results include positive impacts on local practice and national policy, for example adoption within National Institute for Health and Care Evidence (NICE) guidance and Local Authority public health plans and utilization as a tool for local audit of practice and commissioning. The framework was successful in its non-linear approach to knowledge translation across a range of inter-connected activity, built on national leadership, knowledge brokerage, coalition building and a strong collaboration between research institute and government agency.

  20. Lessons Learned from Accelerating Opportunity. Lessons Learned Series

    ERIC Educational Resources Information Center

    Wilson, Randall

    2015-01-01

    The Accelerating Opportunity initiative helps our nation's lowest-skilled adults earn college credentials and enter higher-wage jobs faster by combining the Adult Basic Education and career and technical training they need into one integrated curriculum. Based on four years of designing and managing Accelerating Opportunity, Jobs for the Future…

  1. The ADVANCE network: accelerating data value across a national community health center network

    PubMed Central

    DeVoe, Jennifer E; Gold, Rachel; Cottrell, Erika; Bauer, Vance; Brickman, Andrew; Puro, Jon; Nelson, Christine; Mayer, Kenneth H; Sears, Abigail; Burdick, Tim; Merrell, Jonathan; Matthews, Paul; Fields, Scott

    2014-01-01

    The ADVANCE (Accelerating Data Value Across a National Community Health Center Network) clinical data research network (CDRN) is led by the OCHIN Community Health Information Network in partnership with Health Choice Network and Fenway Health. The ADVANCE CDRN will ‘horizontally’ integrate outpatient electronic health record data for over one million federally qualified health center patients, and ‘vertically’ integrate hospital, health plan, and community data for these patients, often under-represented in research studies. Patient investigators, community investigators, and academic investigators with diverse expertise will work together to meet project goals related to data integration, patient engagement and recruitment, and the development of streamlined regulatory policies. By enhancing the data and research infrastructure of participating organizations, the ADVANCE CDRN will serve as a ‘community laboratory’ for including disadvantaged and vulnerable patients in patient-centered outcomes research that is aligned with the priorities of patients, clinics, and communities in our network. PMID:24821740

  2. Coaching versus Direct Service Models for University Training to Accelerated Schools.

    ERIC Educational Resources Information Center

    Kirby, Peggy C.; Meza, James, Jr.

    This paper examines the changing roles and relationships of schools, central offices, and university facilitators at 11 schools that implemented the nationally recognized Accelerated Schools process. The schools joined the Louisiana Accelerated Schools Network in the summer of 1994. The paper begins with an overview of the Accelerated Schools…

  3. CADC and CANFAR: Extending the role of the data centre

    NASA Astrophysics Data System (ADS)

    Gaudet, Severin

    2015-12-01

    Over the past six years, the CADC has moved beyond the astronomy archive data centre to a multi-service system for the community. This evolution is based on two major initiatives. The first is the adoption of International Virtual Observatory Alliance (IVOA) standards in both the system and data architecture of the CADC, including a common characterization data model. The second is the Canadian Advanced Network for Astronomical Research (CANFAR), a digital infrastructure combining the Canadian national research network (CANARIE), cloud processing and storage resources (Compute Canada) and a data centre (Canadian Astronomy Data Centre) into a unified ecosystem for storage and processing for the astronomy community. This talk will describe the architecture and integration of IVOA and CANFAR services into CADC operations, the operational experiences, the lessons learned and future directions

  4. Interdisciplinary Study of Egyptian Mummies from the Pushkin State Museum of Fine Arts Collection at the National Research Centre ``Kurchatov Institute''

    NASA Astrophysics Data System (ADS)

    Yatsishina, E. B.; Kovalchuk, M. V.; Loshak, M. D.; Vasilyev, S. V.; Vasilieva, O. A.; Dyuzheva, O. P.; Pojidaev, V. M.; Ushakov, V. L.

    2018-05-01

    Nine ancient Egyptian mummies (dated preliminarily to the period from the 1st mill. BCE to the first centuries CE) from the collection of the State Pushkin Museum of Fine Arts have been studied at the National Research Centre "Kurchatov Institute" (NRC KI) on the base of the complex of NBICS technologies. Tomographic scanning is performed using a magneto-resonance tomograph (3 T) and a hybrid positron emission tomography/computed tomography (PET-CT) scanner. Three-dimensional reconstructions of mummies and their anthropological measurements are carried out. Some medical conclusions are drawn based on the tomographic data. In addition, the embalming composition and tissue of one of the mummies are preliminarily analyzed.

  5. Psychological Adjustment in a College-Level Program of Marked Academic Acceleration.

    ERIC Educational Resources Information Center

    Robinson, Nancy M.; Janos, Paul M.

    1986-01-01

    The questionnaire responses of 24 markedly accelerated young students at the University of Washington were compared with those of 24 regular-aged university students, 23 National Merit Scholors, and 27 students who had qualified for acceleration but instead elected to participate in high school. Accelerants appeared as well adjusted as all…

  6. University-Industry Interaction in the Ontario Centres of Excellence.

    ERIC Educational Resources Information Center

    Bell, Stephen

    1996-01-01

    The development and enhancement of alliances among universities, industry, and government is widely seen as a prescription for strengthening the competitiveness of regional and national economies. The interaction of university and industrial scientists is examined, and whether the creation of Ontario's Centres of Excellence should serve as a model…

  7. The cyclotron laboratory and the RFQ accelerator in Bern

    NASA Astrophysics Data System (ADS)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Scampoli, P.; von Bremen, K.; Weber, M.

    2013-07-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  8. Estimation of content of anti-TB drugs supplied at centres of the Revised National TB Control Programme in Tamil Nadu, India.

    PubMed

    Ramachandran, Geetha; Chandrasekaran, Vedachalam; Hemanth Kumar, Agibothu Kupparam; Dewan, Puneet; Swaminathan, Soumya; Thomas, Aleyamma

    2013-09-01

    To determine the content of certain antituberculosis (TB) drugs supplied at TB treatment centres of the Revised National TB Control Programme (RNTCP) in the state of Tamil Nadu, India. Eight districts across the state were selected, and the following drugs were collected from five settings (District TB centre, TB unit, designated microscopy centres, DOT providers) in each district: rifampicin (150 and 450 mg), isoniazid (300 mg), pyrazinamide (500 and 750 mg), ethambutol (400 and 600 mg), ethionamide (250 mg), levofloxacin (500 mg) and cycloserine (250 mg). A maximum of 10 tablets/capsules were collected from each setting. The drugs were coded prior to analysis. All drugs were assayed by validated spectrophotometric methods. The acceptable limits for drug content were taken as 90-110% of the stated content. More than 90% of tablets of rifampicin 450 mg, isoniazid 300 mg, pyrazinamide 500 and 750 mg, ethambutol 400 and 600 mg and ethionamide 250 mg were within acceptable limits. Eighty per cent of rifampicin 150 mg, 21% of cycloserine 250 mg and 87% of levofloxacin 500 mg were within acceptable limits. The mean cycloserine content was below the acceptable limit in all districts, the mean drug content being 200 mg (range: 108-245 mg). This systematic study showed that the stated drug content of cycloserine was not reached in all districts. Deterioration of cycloserine could be minimised by storing the drug in refrigerators. The geographical location of the districts had no influence on the drug content. © 2013 John Wiley & Sons Ltd.

  9. Antimicrobial resistance pattern of Neisseria gonorrhoeae isolates from peripheral health centres and STD clinic attendees of a tertiary care centre in India.

    PubMed

    Bala, M; Ray, K; Gupta, S M

    2008-06-01

    The aim of the study was to compare the antimicrobial resistance pattern of Neisseria gonorrhoeae isolates from urban and rural peripheral health centres and from sexually transmitted disease (STD) clinic attendees. Antimicrobial susceptibility testing of 191 N. gonorrhoeae isolates (165 isolates from STD clinic attendees and 26 from peripheral health centres) was carried out in Delhi, India, using the calibrated dichotomous sensitivity technique for penicillin, tetracycline, ceftriaxone, ciprofloxacin, spectinomycin and nalidixic acid, and minimum inhibitory concentrations were determined using E-test. Penicillin-resistant, ciprofloxacin-resistant, penicillinase-producing N. gonorrhoeae and tetracycline-resistant N. gonorrhoeae strains were higher in STD clinic attendees than in peripheral health centres, probably because of less antibiotic pressure in the peripheral areas. High-level resistance to ciprofloxacin and multiresistant strains were also higher in STD clinic attendees. The present study emphasizes the importance of surveillance of antimicrobial resistance of N. gonorrhoeae in different population subgroups in order to monitor the spread of multiresistant strains and to update the national treatment recommendations.

  10. Singapore National Medical Image Resource Centre (SN.MIRC): a world wide web resource for radiology education.

    PubMed

    Yang, Guo-Liang; Lim, C C Tchoyoson

    2006-08-01

    Radiology education is heavily dependent on visual images, and case-based teaching files comprising medical images can be an important tool for teaching diagnostic radiology. Currently, hardcopy film is being rapidly replaced by digital radiological images in teaching hospitals, and an electronic teaching file (ETF) library would be desirable. Furthermore, a repository of ETFs deployed on the World Wide Web has the potential for e-learning applications to benefit a larger community of learners. In this paper, we describe a Singapore National Medical Image Resource Centre (SN.MIRC) that can serve as a World Wide Web resource for teaching diagnostic radiology. On SN.MIRC, ETFs can be created using a variety of mechanisms including file upload and online form-filling, and users can search for cases using the Medical Image Resource Center (MIRC) query schema developed by the Radiological Society of North America (RSNA). The system can be improved with future enhancements, including multimedia interactive teaching files and distance learning for continuing professional development. However, significant challenges exist when exploring the potential of using the World Wide Web for radiology education.

  11. Miniature penetrator (MinPen) acceleration recorder development test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franco, R.J.; Platzbecker, M.R.

    1998-08-01

    The Telemetry Technology Development Department at Sandia National Laboratories actively develops and tests acceleration recorders for penetrating weapons. This new acceleration recorder (MinPen) utilizes a microprocessor-based architecture for operational flexibility while maintaining electronics and packaging techniques developed over years of penetrator testing. MinPen has been demonstrated to function in shock environments up to 20,000 Gs. The MinPen instrumentation development has resulted in a rugged, versatile, miniature acceleration recorder and is a valuable tool for penetrator testing in a wide range of applications.

  12. Development and piloting the Woman Centred Care Scale (WCCS).

    PubMed

    Brady, Susannah; Bogossian, Fiona; Gibbons, Kristen

    2017-06-01

    In midwifery we espouse a woman centred care approach to practice, yet in midwifery education no valid instrument exists with which to measure the performance of these behaviours in midwifery students. To develop and validate an instrument to measure woman centred care behaviours in midwifery students. We identified four core concepts; woman's sphere, holism, self-determination and the shared power relationship. We mapped 18 individual descriptive care behaviours (from the Australian National Competency Standards for the Midwife) to these concepts to create an instrument to articulate and measure care behaviours that are specifically woman centred. Review by expert midwifery clinicians ensured face, content and construct validity of the scale and predictive validity and reliability were tested in a simulated learning environment. Midwifery students were video recorded performing a clinical skill and the videos were reviewed and rated by two expert clinicians who assessed the woman centred care behaviours demonstrated by the students (n=69). Test and re-test reliability of the instrument was high for each of the individual raters (Kappa 0.946 and 0.849 respectively p<0.001). However, when raters were compared there were differences between their scores suggesting variation in their expectations of woman centred care behaviours (Kappa 0.470, p<0.001). Midwifery students who had repeated exposures to higher levels of simulation fidelity demonstrated higher levels of woman centred care behaviours. The WCCS has implications for education and the wider midwifery profession in recognising and maintaining practice consistent with the underlying philosophy of woman centred care. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  13. A guide to multi-centre ethics for surgical research in Australia and New Zealand.

    PubMed

    Boult, Maggi; Fitzpatrick, Kate; Maddern, Guy; Fitridge, Robert

    2011-03-01

    This paper describes existing inconsistencies as well as the disparate processes and logistics required when obtaining ethics approval in Australia and New Zealand in order to initiate a multi-centre bi-national surgical trial. The endovascular aortic aneurysm repair trial is a large multi-centre trial that aims to obtain pre- and post-operative data from patients in hospitals across Australia and New Zealand. As the trial was research based, ethics applications were submitted to all hospitals where surgeons wished to be involved in the trial. Few ethics committees have embraced attempts to simplify the application process for multi-centre trials. There was limited mutual review between Human Research Ethics Committees necessitating the submission of multiple applications. Though the use of the National Ethics Application Form in ethical review is increasing, some Human Research Ethics Committees do not accept it in its entirety; many require site-specific applications or sections of the Common Application Form modules. Queensland, New South Wales and New Zealand were the easiest systems to prepare, submit and lodge ethics applications because of their understanding and accommodation of reviewing multi-centred trials. The time, expense and complexity of obtaining ethics approval for multi-centre research projects are impediments to their establishment and reduce the time available for research. Australia is working to implement a system named the Harmonisation of Multi-centre Ethical Review to ease the process of obtaining multi-centre ethics clearance. Our experience suggests there will be some teething problems with implementation and acceptance. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.

  14. Quasi-stable injection channels in a wakefield accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiltshire-Turkay, Mara; Farmer, John P.; Pukhov, Alexander

    2016-05-15

    The influence of initial position on the acceleration of externally injected electrons in a plasma wakefield is investigated. Test-particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the wake centre. Particles injected into these channels remain in the wake for a considerable time after dephasing and as a result achieve significantly higher energy than their neighbours. The result is relevant to both the planning and optimisation of experiments making use of external injection.

  15. Resource variation in colorectal surgery: a national centre level analysis.

    PubMed

    Drake, T M; Lee, M J; Senapati, A; Brown, S R

    2017-07-01

    Delivery of quality colorectal surgery requires adequate resources. We set out to assess the relationship between resources and outcomes in English colorectal units. Data were extracted from the Association of Coloproctology of Great Britain and Ireland resource questionnaire to profile resources. This was correlated with Hospital Episode Statistics outcome data including 90-day mortality and readmissions. Patient satisfaction measures were extracted from the Cancer Experience Patient Survey and compared at unit level. Centres were divided by workload into low, middle and top tertile. Completed questionnaires were received from 75 centres in England. Service resources were similar between low and top tertiles in access to Confidential Enquiry into Patient Outcome and Death (CEPOD) theatre, level two or three beds per 250 000 population or the likelihood of having a dedicated colorectal ward. There was no difference in staffing levels per 250 000 unit of population. Each 10% increase in the proportion of cases attempted laparoscopically was associated with reduced 90-day unplanned readmission (relative risk 0.94, 95% CI 0.91-0.97, P < 0.001). The presence of a dedicated colorectal ward (relative risk 0.85, 95% CI 0.73-0.99, P = 0.040) was also associated with a significant reduction in unplanned readmissions. There was no association between staffing or service factors and patient satisfaction. Resource levels do not vary based on unit of population. There is benefit associated with increased use of laparoscopy and a dedicated surgical ward. Alternative measures to assess the relationship between resources and outcome, such as failure to rescue, should be explored in UK practice. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  16. Paraquat poisoning calls to the Malaysia National Poison Centre following its ban and subsequent restriction of the herbicide from 2004 to 2015.

    PubMed

    Leong, Yin-Hui; Ariff, Adilah Mohamed; Khan, Halilol Rahman Mohamed; Rani, Noor Afiza Abdul; Majid, Mohamed Isa Abdul

    2018-05-01

    This study analyses the incidences and patterns of paraquat poisoning from calls received at the Malaysia National Poison Centre (NPC) since 2004 following the ban of the herbicide (2004-2006) and subsequent restriction up to year 2015. Related reported cases to the centre over twelve years (2004-2015) were retrieved and studied in respect to socio-demographic characteristics, mode and type of poisonings, exposure routes and location of incident. Ages of poisoned victims range from 10 months old to 98 years with males being intoxicated more frequently than females (ratio male to female = 2.7). The age group mainly involved in the poisoning was 20-39 years. The most common mode was intentional (62.8%) followed by unintentional (36.9%). Among the 1232 reported cases, suicidal poisoning was the highest (57.2%); accidental poisoning (30.8%) and occupational poisoning (3.3%). The findings showed an upward trend of suicidal poisoning over the years, clearly emphasizing the need for more stringent and effective enforcement to ensure the safe use of paraquat. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  17. First results of the Nordic and Baltic GNSS Analysis Centre

    NASA Astrophysics Data System (ADS)

    Lahtinen, Sonja; Pasi, Häkli; Jivall, Lotti; Kempe, Christina; Kollo, Karin; Kosenko, Ksenija; Pihlak, Priit; Prizginiene, Dalia; Tangen, Oddvar; Weber, Mette; Paršeliūnas, Eimuntas; Baniulis, Rimvydas; Galinauskas, Karolis

    2018-03-01

    The Nordic Geodetic Commission (NKG) has launched a joint NKG GNSS Analysis Centre that aims to routinely produce high qualityGNSS solutions for the common needs of the NKG and the Nordic and Baltic countries. A consistent and densified velocity field is needed for the constraining of the gla-cial isostatic adjustment (GIA) modelling that is a key component of maintaining the national reference frame realisations in the area. We described the methods of the NKG GNSS Analysis Centre including the defined processing setup for the local analysis centres (LAC) and for the combination centres.We analysed the results of the first 2.5 years (2014.5-2016). The results showed that different subnets were consistent with the combined solution within 1-2 mm level. We observed the so called network effect affecting our reference frame alignment. However, the accuracy of the reference frame alignment was on a few millimetre level in the area of the main interest (Nordic and Baltic Countries). TheNKGGNSS AC was declared fully operational in April 2017.

  18. What specifications for a centre or network of excellence in clinical research?

    PubMed

    Diebolt, Vincent; Lang, Marie; Thoby, Frédérique

    2016-02-01

    The Giens 2015 Workshop Round Table entitled "What specifications for a centre or network of excellence in clinical research?" took a viewpoint distinct from earlier work and studies on changes in clinical research activities in France. The purpose of the present work was to identify, starting from concrete examples, the main strengths and advantages of clinical research activity in France related, in part, to the background environment and also to the specific characteristics of the investigation centres considered to be among the most high-performance units in activity. The criteria retained were grouped into a set of specifications that could be used to establish a "label of excellence" upon which the different teams and clinical research centres could model themselves. It was thus considered that belonging to a centre or structured network with at least a national configuration, when this is possible for the medial topic in question, constitutes a real advantage. Four benchmarks were identified: the scientific and clinical expertise of the head investigator, as well as the qualification and operational capacity of the centre's team; definition and measurement of performance using clearly displayed indicators and evaluation procedures; the quality of the overall trial "process" and of each of its component steps; communication, because know-how and promotion go hand in hand, with the main objective of informing the professional and general public about the value of the research centre meeting the above-mentioned criteria, about its networks of competencies, and more generally, about the important assets of the background of clinical research in France. This sector of research is funded by the public authorities via calls for public grants, financial aids for structures supporting clinical research in the University Hospital Centres and other healthcare institutions allowing for a professionalization of the research occupations, and the national public health

  19. Impact of national smokefree environments laws on teachers, schools and early childhood centres.

    PubMed

    Watson, Donna; Glover, Marewa; McCool, Judith; Bullen, Chris; Adams, Brian; Min, Sandar

    2011-12-01

    New Zealand's (NZ) smokefree legislation, implemented on 1 January 2004, requires that all school and early childhood centre buildings and grounds are 100% smokefree; one aim being to prevent young people being influenced by seeing people (including teachers) smoke there. This study, conducted in 2008, investigated teachers'smoking behaviour and perceived adherence to the legislation. A national NZ cross-sectional survey of 2,004 teachers (oversampling Māori), who were randomly selected from the electoral roll of registered voters and sent postal invitations to complete an anonymous survey. The response rate was 70%. Current smokers numbered 7%, and proportionately more Maori and Pacific Island teachers (12% each) smoked than European/Other teachers (7%). Of current smokers, 37% smoked non-daily. Smokers smoked less on work than non-work days. Introducing smokefree legislation was associated with teachers changing when they smoked, cutting down, quitting or trying to quit. Perceived compliance with the legislation was high, although 30% of teachers reported seeing staff smoking. Proportionately, significantly more teachers from low than from high socioeconomic schools perceived poor compliance and staff visibly smoking. Smokefree legislation affects people's smoking behaviour. Smoking in NZ is becoming confined to population subgroups defined by socioeconomic status and ethnicity. Our findings argue for supporting cessation among those who work with children and young people, and for targeting support at school communities in areas of low socioeconomic status or with large populations of Māori or Pacific peoples.

  20. Radiation protection challenges in the management of radioactive waste from high-energy accelerators.

    PubMed

    Ulrici, Luisa; Algoet, Yvon; Bruno, Luca; Magistris, Matteo

    2015-04-01

    The European Laboratory for Particle Physics (CERN) has operated high-energy accelerators for fundamental physics research for nearly 60 y. The side-product of this activity is the radioactive waste, which is mainly generated as a result of preventive and corrective maintenance, upgrading activities and the dismantling of experiments or accelerator facilities. Prior to treatment and disposal, it is common practice to temporarily store radioactive waste on CERN's premises and it is a legal requirement that these storage facilities are safe and secure. Waste treatment typically includes sorting, segregation, volume and size reduction and packaging, which will depend on the type of component, its chemical composition, residual activity and possible surface contamination. At CERN, these activities are performed in a dedicated waste treatment centre under the supervision of the Radiation Protection Group. This paper gives an overview of the radiation protection challenges in the conception of a temporary storage and treatment centre for radioactive waste in an accelerator facility, based on the experience gained at CERN. The CERN approach consists of the classification of waste items into 'families' with similar radiological and physical-chemical properties. This classification allows the use of specific, family-dependent techniques for radiological characterisation and treatment, which are simultaneously efficient and compliant with best practices in radiation protection. The storage was planned on the basis of radiological and other possible hazards such as toxicity, pollution and fire load. Examples are given of technical choices for the treatment and radiological characterisation of selected waste families, which could be of interest to other accelerator facilities. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A portable platform for accelerated PIC codes and its application to GPUs using OpenACC

    NASA Astrophysics Data System (ADS)

    Hariri, F.; Tran, T. M.; Jocksch, A.; Lanti, E.; Progsch, J.; Messmer, P.; Brunner, S.; Gheller, C.; Villard, L.

    2016-10-01

    We present a portable platform, called PIC_ENGINE, for accelerating Particle-In-Cell (PIC) codes on heterogeneous many-core architectures such as Graphic Processing Units (GPUs). The aim of this development is efficient simulations on future exascale systems by allowing different parallelization strategies depending on the application problem and the specific architecture. To this end, this platform contains the basic steps of the PIC algorithm and has been designed as a test bed for different algorithmic options and data structures. Among the architectures that this engine can explore, particular attention is given here to systems equipped with GPUs. The study demonstrates that our portable PIC implementation based on the OpenACC programming model can achieve performance closely matching theoretical predictions. Using the Cray XC30 system, Piz Daint, at the Swiss National Supercomputing Centre (CSCS), we show that PIC_ENGINE running on an NVIDIA Kepler K20X GPU can outperform the one on an Intel Sandy bridge 8-core CPU by a factor of 3.4.

  2. Production and isolation of homologs of flerovium and element 115 at the Lawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry

    DOE PAGES

    Despotopulos, John D.; Kmak, Kelly N.; Gharibyan, Narek; ...

    2015-10-01

    Here, new procedures have been developed to isolate no-carrier-added (NCA) radionuclides of the homologs and pseudo-homologs of flerovium (Hg, Sn) and element 115 (Sb), produced by 12–15 MeV proton irradiation of foil stacks with the tandem Van-de-Graaff accelerator at the Lawrence Livermore National Laboratory Center for Accelerator Mass Spectrometry (CAMS) facility. The separation of 113Sn from natIn foil was performed with anion-exchange chromatography from hydrochloric and nitric acid matrices. A cation-exchange chromatography method based on hydrochloric and mixed hydrochloric/hydroiodic acids was used to separate 124Sb from natSn foil. A procedure using Eichrom TEVA resin was developed to separate 197Hg frommore » Au foil. These results demonstrate the suitability of using the CAMS facility to produce NCA radioisotopes for studies of transactinide homologs.« less

  3. The joint cardiovascular research profile of the university medical centres in the Netherlands.

    PubMed

    van Welie, S D; van Leeuwen, T N; Bouma, C J; Klaassen, A B M

    2016-05-01

    Biomedical scientific research in the Netherlands has a good reputation worldwide. Quantitatively, the university medical centres (UMCs) deliver about 40 % of the total number of scientific publications of this research. Analysis of the bibliometric output data of the UMCs shows that their research is highly cited. These output-based analyses also indicate the high impact of cardiovascular scientific research in these centres, illustrating the strength of this research in the Netherlands. A set of six joint national cardiovascular research topics selected by the UMCs can be recognised. At the top are heart failure, rhythm disorder research and atherosclerosis. National collaboration of top scientists in consortia in these three areas is successful in acquiring funding of large-scale programs. Our observations suggest that funding national consortia of experts focused on a few selected research topics may increase the international competitiveness of cardiovascular research in the Netherlands.

  4. Ninety day mortality following pancreatoduodenectomy in England: has the optimum centre volume been identified?

    PubMed

    Liu, Z; Peneva, I S; Evison, F; Sahdra, S; Mirza, D F; Charnley, R M; Savage, R; Moss, P A; Roberts, K J

    2018-06-09

    Mortality following pancreatoduodenectomy is related to centre volume although the optimal volume is not defined. Patients undergoing PD between 2001 and 2016 were identified from UK national databases. The effects of patient variables, centre volume and time period upon 90 day mortality were studied. 90 day mortality (970/14,935, 6.5%) was related to advanced age, comorbidity, diagnosis, ethnicity, deprivation, centre volume and time period. Mortality rates fell markedly from 10.0% in 2001-4 to 4.1% in 2013-16. There was no difference in 90 day mortality between high (36 -60 PD per year) and very high volume (>60) centres. However, patients operated upon at very high volume centres were more elderly (66, 58 -73 vs 65, 56 -72; median, IQR; p = 0.006), deprived (38.7 vs 34.6%; p < 0.001) and co morbid (48.9 vs 46.1%; p = 0.027). Although a plateau in the centre volume and mortality relationship appears to have been demonstrated those patients treated at the highest volume centres were at higher risk of mortality. This data suggests therefore that to further understand outcomes from specialist centres characteristics of the patient population should be defined, not just centre volume. Copyright © 2018. Published by Elsevier Ltd.

  5. A statistical investigation of the mass discrepancy-acceleration relation

    NASA Astrophysics Data System (ADS)

    Desmond, Harry

    2017-02-01

    We use the mass discrepancy-acceleration relation (the correlation between the ratio of total-to-visible mass and acceleration in galaxies; MDAR) to test the galaxy-halo connection. We analyse the MDAR using a set of 16 statistics that quantify its four most important features: shape, scatter, the presence of a `characteristic acceleration scale', and the correlation of its residuals with other galaxy properties. We construct an empirical framework for the galaxy-halo connection in LCDM to generate predictions for these statistics, starting with conventional correlations (halo abundance matching; AM) and introducing more where required. Comparing to the SPARC data, we find that: (1) the approximate shape of the MDAR is readily reproduced by AM, and there is no evidence that the acceleration at which dark matter becomes negligible has less spread in the data than in AM mocks; (2) even under conservative assumptions, AM significantly overpredicts the scatter in the relation and its normalization at low acceleration, and furthermore positions dark matter too close to galaxies' centres on average; (3) the MDAR affords 2σ evidence for an anticorrelation of galaxy size and Hubble type with halo mass or concentration at fixed stellar mass. Our analysis lays the groundwork for a bottom-up determination of the galaxy-halo connection from relations such as the MDAR, provides concrete statistical tests for specific galaxy formation models, and brings into sharper focus the relative evidence accorded by galaxy kinematics to LCDM and modified gravity alternatives.

  6. Field stabilization studies for a radio frequency quadrupole accelerator

    NASA Astrophysics Data System (ADS)

    Gaur, R.; Kumar, V.

    2014-07-01

    The Radio Frequency Quadrupole (RFQ) linear accelerator is an accelerator that efficiently focuses, bunches and accelerates a high intensity DC beam from an ion source, for various applications. Unlike other conventional RF linear accelerators, the electromagnetic mode used for its operation is not the lowest frequency mode supported by the structure. In a four vane type RFQ, there are several undesired electromagnetic modes having frequency close to that of the operating mode. While designing an RFQ accelerator, care must be taken to ensure that the frequencies of these nearby modes are sufficiently separated from the operating mode. If the undesired nearby modes have frequencies close to the operating mode, the electromagnetic field pattern in the presence of geometrical errors will not be stabilized to the desired field profile, and will be perturbed by the nearby modes. This will affect the beam dynamics and reduce the beam transmission. In this paper, we present a detailed study of the electromagnetic modes supported, which is followed by calculations for implementation of suitable techniques to make the desired operating mode stable against mixing with unwanted modes for an RFQ being designed for the proposed Indian Spallation Neutron Source (ISNS) project at Raja Ramanna Centre for Advanced Technology, Indore. Resonant coupling scheme, along with dipole stabilization rods has been proposed to increase the mode separation. The paper discusses the details of a generalized optimization procedure that has been used for the design of mode stabilization scheme.

  7. European guidelines for the accreditation of Sleep Medicine Centres.

    PubMed

    Pevernagie, Dirk

    2006-06-01

    This document describes guidelines for accreditation of Sleep Medicine Centres in Europe. These guidelines are the result of a consensus procedure, in which representatives of the European Sleep Research Society (ESRS) and representatives of different European National Sleep Societies (ENSS) were involved. The information obtained during different rounds of consultation was gathered and processed by the members of the Steering Committee of the ESRS. The scope of the guidelines is to define the characteristics of multidisciplinary Sleep Medicine Centres (SMCs), in terms of requirements regarding staff, operational procedures and logistic facilities. Accreditation of SMCs is proposed to be the responsibility of the individual ENSS. The Accreditation Guidelines may thus be considered an instrument for the national societies to develop new or standardize existing accreditation questionnaires, as well as procedures for visiting the site, drafting the accreditation report, and finally, granting the accreditation. The Accreditation Guidelines are meant to be a line of action, that ideally should be followed as close as possible, but that may be subject to certain exceptions, depending on local customs or regulations.

  8. Accelerator boom hones China's engineering expertise

    NASA Astrophysics Data System (ADS)

    Normile, Dennis

    2018-02-01

    In raising the curtain on the China Spallation Neutron Source, China has joined just four other nations in having mastered the technology of accelerating and controlling beams of protons. The $277 million facility, set to open to users this spring in Dongguan, is expected to yield big dividends in materials science, chemistry, and biology. More world class machines are on the way, as China this year starts construction on four other major accelerator facilities. The building boom is prompting a scramble to find enough engineers and technicians to finish the projects. But if they all come off as planned, the facilities would position China to tackle the next global megaproject: a giant accelerator that would pick up where Europe's Large Hadron Collider leaves off.

  9. Chapter 9 Biochemical variables amongst UK adult dialysis patients in 2010: national and centre-specific analyses.

    PubMed

    Pruthi, Rishi; Pitcher, David; Dawnay, Anne

    2012-01-01

    The UK Renal Association clinical practice guidelines include clinical performance measures for biochemical variables in dialysis patients. The UK Renal Registry (UKRR) annually audits dialysis centre performance against these measures as part of its role in promoting continuous quality improvement. Cross sectional performance analyses were undertaken to compare dialysis centre achievement of clinical audit measures for prevalent haemodialysis (HD) and peritoneal dialysis (PD) cohorts in 2010. The biochemical variables studied were phosphate, adjusted calcium, parathyroid hormone, bicarbonate and total cholesterol. In addition longitudinal analyses were performed (2000-2010) to show changes in achievement of clinical performance measures over time. Fifty-six percent of HD and 69% of PD patients achieved a phosphate within the range recommended by the RA clinical practice guidelines. Seventy-five percent of HD and 76% of PD patients had adjusted calcium between 2.2-2.5 mmol/L. Twenty-eight percent of HD and 31% of PD patients had parathyroid hormone between 16- 32 pmol/L. Sixty percent of HD and 80% of PD patients achieved the audit measure for bicarbonate. There was significant inter-centre variation for all variables studied. The UKRR consistently demonstrates significant inter-centre variation in achievement of biochemical clinical audit measures. Understanding the causes of this variation is an important part of improving the care of dialysis patients in the UK. Copyright © 2012 S. Karger AG, Basel.

  10. The "Conservatoire National des Arts et Metiers"

    ERIC Educational Resources Information Center

    Kuhn, Gerard

    2004-01-01

    The overall mission of the Conservatoire national des arts et metiers--(CNAM) [National Conservatory of Industrial Arts and Trades] is outlined. One of its centers, the "Centre national de l'entrepreneuriat"--(CNE) [National Center for Entrepreneurship] is described in greater detail. In particular, this center offers various services, notably…

  11. Indigenous Cultural Self-Representation and Its Internal Critiques: A Case Study of the Woodland Cultural Centre, Canada

    ERIC Educational Resources Information Center

    Nakamura, Naohiro

    2014-01-01

    This research report discusses Indigenous cultural representation and its internal critiques, based on the case study of an Indigenous-run museum, the Woodland Cultural Centre, in Canada. Since its establishment in 1972, the Woodland Cultural Centre has strived to promote Indigenous culture, especially First Nations art, and has challenged the…

  12. The cyclotron laboratory and the RFQ accelerator in Bern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braccini, S.; Ereditato, A.; Kreslo, I.

    2013-07-18

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University ofmore » Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.« less

  13. Audit of sweat testing: a first report from Italian Cystic Fibrosis Centres.

    PubMed

    Cirilli, Natalia; Padoan, Rita; Raia, Valeria

    2008-09-01

    Cystic Fibrosis diagnosis is confirmed using sweat test. The aim of our study was to evaluate current techniques and methodologies in use at Italian CF Care Centres. A series of questions related to the performance of the sweat test was collected by all CF Care Centres in Italy. Answers were compared with UK and NCCLS guidelines. 39/41 Centres replied to the questionnaire. A good adherence to guidelines was registered for storing samples before analysis in 90.9%, while performing CF diagnosis by at least two sweat tests, and chloride analysis were reported respectively in 100% and 75.7% of Centres. Some inconsistencies were registered for minimum acceptable sweat quantity and time to collect sweat inadequate in respectively 42.5% and 24.2% of Centres, while performing quality control procedures and referring to an external quality assessment scheme were found inadequate in respectively 54.6% and 100%. 57.6% didn't provide any appropriate analytical ranges and only 15.1% of Centres offered proper information to patients/parents. A report form, including sweat quantity, reference ranges and interpretation, was adequate only for 9.4 up to 41.4% of CF Centres. Our study showed areas of inconsistencies in sweat testing current practices in Italy and highlights the need for evidence based national guidelines to improve practice and management strategies.

  14. Plasma Wake-field Acceleration in the Blow-out Regime

    NASA Astrophysics Data System (ADS)

    Barov, Nikolai; Rosenzweig, James

    1999-11-01

    Recent experiments at Argonne National Laboratory, investigating the blow-out regime of the plasma wake-field accelerator, are discussed. These experiments achieved stable underdense (beam denser than the ambient plasma density) beam transport, and measured average acceleration of 25 MV/m, corresponding to peak wave fields of over 60 MVm. A comparison of the results to simulation is given, and the physics of the system is discussed. Potential for improvements in performance and achieved acceleration gradient, as well as accelerated beam quality are examined within the context of the next generation of experiments at the Fermilab Test Facility. The status of these experiments will be given.

  15. Anomalous gravitropic response of Chara rhizoids during enhanced accelerations.

    PubMed

    Braun, M

    1996-07-01

    Centrifugal accelerations of 50-250 g were applied to rhizoids of Chara globularis Thuill. at stimulation angles (alpha) of 5-90 degrees between the acceleration vector and the rhizoid axis. After the start of centrifugation, the statoliths were pressed asymmetrically onto the centrifugal flank of the apical cell wall. In contrast to the well-known bending (by bowing) under 1 g, the rhizoids responded in two distinct phases. Following an initial phase of sharp bending (by bulging), which is similar to the negatively gravitropic response of Chara protonemata, rhizoids stopped bending and, in the second phase, grew straight in directions clearly deviating from the direction of acceleration. These response angles (beta) between the axis of the bent part of the rhizoid and the acceleration vector were strictly correlated with the g-level of acceleration. The higher the acceleration the greater was beta. Except for the sharp bending, the shape and growth rate of the centrifuged rhizoids were not different from those of gravistimulated control rhizoids at 1 g. These results indicate that gravitropic bending of rhizoids during enhanced accelerations (5 degrees < or = alpha < or = 90 degrees) is caused not only by subapical differential flank growth, as it is the case at 1 g, but also by also by the centripetal displacement of the growth centre as was recently discussed for the negative gravitropism of Chara protonemata. A hypothesis for cytoskeletally mediated polar growth is presented based on data from positive gravitropic bending of Chara rhizoids at 1 g and from the anomalous gravitropic bending of rhizoids compared with the negatively gravitropic bending of Chara protonemata. The data obtained are also relevant to a general understanding of graviperception in higher-plant organs.

  16. Reproducing ten years of road ageing--accelerated carbonation and leaching of EAF steel slag.

    PubMed

    Suer, Pascal; Lindqvist, Jan-Erik; Arm, Maria; Frogner-Kockum, Paul

    2009-09-01

    Reuse of industrial aggregates is still hindered by concern for their long-term properties. This paper proposes a laboratory method for accelerated ageing of steel slag, to predict environmental and technical properties, starting from fresh slag. Ageing processes in a 10-year old asphalt road with steel slag of electric arc furnace (EAF) type in the subbase were identified by scanning electron microscopy (SEM) and leaching tests. Samples from the road centre and the pavement edge were compared with each other and with samples of fresh slag. It was found that slag from the pavement edge showed traces of carbonation and leaching processes, whereas the road centre material was nearly identical to fresh slag, in spite of an accessible particle structure. Batches of moisturized road centre material exposed to oxygen, nitrogen or carbon dioxide (CO2) were used for accelerated ageing. Time (7-14 days), temperature (20-40 degrees C) and initial slag moisture content (8-20%) were varied to achieve the carbonation (decrease in pH) and leaching that was observed in the pavement edge material. After ageing, water was added to assess leaching of metals and macroelements. 12% moisture, CO2 and seven days at 40 degrees C gave the lowest pH value. This also reproduced the observed ageing effect for Ca, Cu, Ba, Fe, Mn, Pb, Ca (decreased leaching) and for V, Si, and Al (increased leaching). However, ageing effects on SO4, DOC and Cr were not reproduced.

  17. 15 Years of R&D on high field accelerator magnets at FNAL

    DOE PAGES

    Barzi, Emanuela; Zlobin, Alexander V.

    2016-07-01

    The High Field Magnet (HFM) Program at Fermi National Accelerator Laboratory (FNAL) has been developing Nb 3Sn superconducting magnets, materials and technologies for present and future particle accelerators since the late 1990s. This paper summarizes the main results of the Nb 3Sn accelerator magnet and superconductor R&D at FNAL and outlines the Program next steps.

  18. A trans-cultural comparison of the organisation of care at headache centres world-wide.

    PubMed

    Bhola, Ria; Goadsby, Peter J

    2011-02-01

    The need to provide better outcomes for patients with headache, and to minimise the costs involved in doing so, has prompted the search for new modes of service delivery by exploring the service organisation and nursing role from various cultural, economic and global perspectives. This study was based on comparisons with the UK headache service up to 2007, the point at which this study was set up. This UK service was based at the National Hospital for Neurology and Neurosurgery (NHNN, UCLH Trust). Data were obtained from US headache centres in 2008 and from centres in Copenhagen, Bangkok, Sydney and Porto Alegre in 2009. A comparison shows the key components of services at all centres showing the team structure and size of service. Prominent features at the centres included: team-working, regular meetings, educational input, good access and communication among team members, headache-trained neurologists, specialist nursing at most centres, and the input of psychological and physical therapists at some centres. The problems of tertiary headache care are very similar throughout the world and seem to transcend ethnic, cultural and economic considerations.

  19. Provision of Vocational Skills Education to Orphans: Lessons from Orphanage Centres in Dar es Salaam City, Tanzania

    ERIC Educational Resources Information Center

    Meli, Benjamin Mbeba

    2015-01-01

    This paper utilises data from a study that investigated the efficacy of vocational skills training provided to orphans from three orphanages in Temeke District, Dar es Salaam. The three orphanage centres that were studied are Kurasini National Children Home, Saudia and Don Bosco Vocational Centre. The sample comprised of 45 orphans, an official…

  20. A proton medical accelerator by the SBIR route — an example of technology transfer

    NASA Astrophysics Data System (ADS)

    Martin, R. L.

    1989-04-01

    Medical facilities for radiation treatment of cancer with protons have been established in many laboratories throughout the world. Essentially all of these have been designed as physics facilities, however, because of the requirement for protons up to 250 MeV. Most of the experience in this branch of accelerator technology lies in the national laboratories and a few large universities. A major issue is the transfer of this technology to the commercial sector to provide hospitals with simple, reliable and relatively inexpensive accelerators for this application. The author has chosen the SBIR route to accomplish this goal. ACCTEK Associates has received grants from the National Cancer Institute for development of the medical accelerator and beam delivery systems. Considerable encouragement and help has been received from Argonne National Laboratory and the Department of Energy. The experiences to date and the pros and cons on this approach to commercializing medical accelerators are described.

  1. Validation of an accelerated high-sensitivity troponin T assay protocol in an Australian cohort with chest pain.

    PubMed

    Parsonage, William A; Greenslade, Jaimi H; Hammett, Christopher J; Lamanna, Arvin; Tate, Jillian R; Ungerer, Jacobus P; Chu, Kevin; Than, Martin; Brown, Anthony F T; Cullen, Louise

    2014-02-17

    To validate an accelerated biomarker strategy using a high-sensitivity cardiac troponin T (hs-cTnT) assay for diagnosing acute myocardial infarction (AMI) in patients presenting to the emergency department with chest pain; and to validate this strategy in combination with the National Heart Foundation of Australia/Cardiac Society of Australia and New Zealand risk stratification model. Single-centre, prospective, observational cohort study of 764 adults presenting to a tertiary hospital with symptoms of possible acute coronary syndrome between November 2008 and February 2011. AMI or cardiac death within 24 hours of presentation (primary), and major adverse cardiac events within 30 days (secondary). An elevated hs-cTnT assay result above the 99th percentile at either the 0 h or 2 h time points had sensitivity of 96.4% (95% CI, 87.9%-99.0%), specificity of 82.6% (95% CI, 79.7%-85.2%), negative predictive value of 99.7% (95% CI, 98.8%-99.9%) and positive predictive value of 30.5% (95% CI, 24.2%-37.6%) for diagnosing AMI. Compared with a traditional 6 h cardiac troponin testing strategy, the accelerated strategy led to reclassification of risk in only two patients with adverse cardiac outcomes, with no net effect on appropriate management. In patients presenting with chest pain, an accelerated biomarker strategy using the hs-cTnT assay performed well in the initial diagnosis of AMI. The accelerated strategy was also effective when incorporated into a comprehensive strategy of risk stratification that included clinical and demographic factors. The time saved by this approach could have a major impact on health service delivery. Australian New Zealand Clinical Trials Registry ACTRN12610000053022.

  2. Acceleration modules in linear induction accelerators

    NASA Astrophysics Data System (ADS)

    Wang, Shao-Heng; Deng, Jian-Jun

    2014-05-01

    The Linear Induction Accelerator (LIA) is a unique type of accelerator that is capable of accelerating kilo-Ampere charged particle current to tens of MeV energy. The present development of LIA in MHz bursting mode and the successful application into a synchrotron have broadened LIA's usage scope. Although the transformer model is widely used to explain the acceleration mechanism of LIAs, it is not appropriate to consider the induction electric field as the field which accelerates charged particles for many modern LIAs. We have examined the transition of the magnetic cores' functions during the LIA acceleration modules' evolution, distinguished transformer type and transmission line type LIA acceleration modules, and re-considered several related issues based on transmission line type LIA acceleration module. This clarified understanding should help in the further development and design of LIA acceleration modules.

  3. The impact of distance and duration of travel on participation rates and participants’ satisfaction: results from a pilot study at one study centre in Pretest 2 of the German National Cohort

    PubMed Central

    Schweitzer, Aparna; Akmatov, Manas K; Kindler, Florentina; Kemmling, Yvonne; Kreienbrock, Lothar; Krause, Gérard; Pessler, Frank

    2015-01-01

    Objectives In this pilot study within the Pretest 2 phase of the German National Cohort, we aimed to (1) test the hypothesis that distance and duration of travel to a study centre may affect participation rates and participants’ satisfaction and (2) to obtain data that would help to select recruitment areas around the study centre Hannover with the greatest projected participation rate for the main study. Setting Mixed urban/suburban environment in Northern Germany with approximately 600 000 inhabitants. 4 recruitment areas with divergent estimated mean distances (range, 7–40 km) and duration of travel to the study centre Hannover were selected. Participants 1050 men and women (ratio, 1:1), aged 20–69 years, were randomly selected from the population registries of the 4 recruitment areas and invited by mail to participate in the Pretest 2 study programme at the study centre Hannover, covering a variety of questionnaire-based and physical assessments. 166 individuals participated (16%). Interventions All 166 participants completed a travel questionnaire containing 5 items relating to travel duration and satisfaction, amounting to a participation rate of 100% in the questionnaire-based part of the study. Results Participation rates in the Pretest 2 programme at the study centre Hannover by area ranged from 11% (area farthest from the study centre, estimated median distance 38 km) to 18% (nearest area, 2 km). The odds of non-participation were highest in the area farthest from the study centre (adjusted OR 2.06; p=0.01; CI 1.28 to 3.32). Nonetheless, 97% of participants were satisfied with travel duration. Conclusions Increasing distance was associated with a lower participation rate. However, acceptance of duration of travel was high, irrespective of distance or duration. Thus, recruiting in farther away locations may select individuals with a greater frustration tolerance for travel to the study centre, perhaps due to a greater interest in

  4. Development of High Power Vacuum Tubes for Accelerators and Plasma Heating

    NASA Astrophysics Data System (ADS)

    Srivastava, Vishnu

    2012-11-01

    High pulsed power magnetrons and klystrons for medical and industrial accelerators, and high CW power klystrons and gyrotrons for plasma heating in tokamak, are being developed at CEERI. S-band 2.0MW pulsed tunable magnetrons of centre frequency 2856MHz and 2998 MHz were developed, and S-band 2.6MW pulsed tunable magnetron is being developed for medical LINAC, and 3MW pulsed tunable magnetron is being developed for industrial accelerator. S-band (2856MHz), 5MW pulsed klystron was developed for particle accelerator, and S-band 6MW pulsed klystron is under development for 10MeV industrial accelerator. 350MHz, 100kW (CW) klystron is being developed for proton accelerator, and C-band 250kW (CW) klystron is being developed for plasma heating. 42GHz, 200kW (CW/Long pulse) gyrotron is under development for plasma heating. Plasma filled tubes are also being developed for switching. 25kV/1kA and 40kV/3kA thyratrons were developed for high voltage high current switching in pulse modulators for magnetrons and klystrons. 25kV/3kA Pseudospark switch of current rise time of 1kA/|a-sec and pulse repetition rate of 500Hz is being developed. Plasma assisted high power microwave device is also being investigated.

  5. A statistical investigation of the mass discrepancy–acceleration relation

    DOE PAGES

    Desmond, Harry

    2016-10-08

    We use the mass discrepancy–acceleration relation (the correlation between the ratio of total-to-visible mass and acceleration in galaxies; MDAR) to test the galaxy–halo connection. Here, we analyse the MDAR using a set of 16 statistics that quantify its four most important features: shape, scatter, the presence of a ‘characteristic acceleration scale’, and the correlation of its residuals with other galaxy properties. We construct an empirical framework for the galaxy–halo connection in LCDM to generate predictions for these statistics, starting with conventional correlations (halo abundance matching; AM) and introducing more where required. Comparing to the SPARC data, we find that: (1)more » the approximate shape of the MDAR is readily reproduced by AM, and there is no evidence that the acceleration at which dark matter becomes negligible has less spread in the data than in AM mocks; (2) even under conservative assumptions, AM significantly overpredicts the scatter in the relation and its normalization at low acceleration, and furthermore positions dark matter too close to galaxies’ centres on average; (3) the MDAR affords 2σ evidence for an anticorrelation of galaxy size and Hubble type with halo mass or concentration at fixed stellar mass. Lastly, our analysis lays the groundwork for a bottom-up determination of the galaxy–halo connection from relations such as the MDAR, provides concrete statistical tests for specific galaxy formation models, and brings into sharper focus the relative evidence accorded by galaxy kinematics to LCDM and modified gravity alternatives.« less

  6. Accelerated roadbuilding on the north umpqua—an economic analysis.

    Treesearch

    Brian R. Payne

    1972-01-01

    This study evaluates the economic desirability of accelerated roadbuilding for access to old-growth timber on a unit of the Umpqua National Forest in Oregon. As of 1966, four accelerated roadbuilding alternatives were found economically inferior to the then current rate of construction. Only in the case of substantial, continuing inflation were projected rates of...

  7. Rayleigh-Taylor mixing with time-dependent acceleration

    NASA Astrophysics Data System (ADS)

    Abarzhi, Snezhana

    2016-10-01

    We extend the momentum model to describe Rayleigh-Taylor (RT) mixing driven by a time-dependent acceleration. The acceleration is a power-law function of time, similarly to astrophysical and plasma fusion applications. In RT flow the dynamics of a fluid parcel is driven by a balance per unit mass of the rates of momentum gain and loss. We find analytical solutions in the cases of balanced and imbalanced gains and losses, and identify their dependence on the acceleration exponent. The existence is shown of two typical regimes of self-similar RT mixing-acceleration-driven Rayleigh-Taylor-type and dissipation-driven Richtymer-Meshkov-type with the latter being in general non-universal. Possible scenarios are proposed for transitions from the balanced dynamics to the imbalanced self-similar dynamics. Scaling and correlations properties of RT mixing are studied on the basis of dimensional analysis. Departures are outlined of RT dynamics with time-dependent acceleration from canonical cases of homogeneous turbulence as well as blast waves with first and second kind self-similarity. The work is supported by the US National Science Foundation.

  8. RTEMS Centre - Support and Maintenance Centre to RTEMS Operating System

    NASA Astrophysics Data System (ADS)

    Silva, H.; Constantino, A.; Freitas, D.; Coutinho, M.; Faustino, S.; Mota, M.; Colaço, P.; Sousa, J.; Dias, L.; Damjanovic, B.; Zulianello, M.; Rufino, J.

    2009-05-01

    RTEMS CENTRE - Support and Maintenance Centre to RTEMS Operating System is a joint ESA/Portuguese Task Force initiative to develop a support and maintenance centre to the Real-Time Executive for Multiprocessor Systems (RTEMS). This paper gives a high level visibility of the progress, the results obtained and the future work in the RTEMS CENTRE [6] and in the RTEMS Improvement [7] projects. RTEMS CENTRE started officially in November 2006, with the RTEMS 4.6.99.2 version. A full analysis of RTEMS operating system was produced. The architecture was analysed in terms of conceptual, organizational and operational concepts. The original objectives [1] of the centre were primarily to create and maintain technical expertise and competences in this RTOS, to develop a website to provide the European Space Community an entry point for obtaining support (http://rtemscentre.edisoft.pt), to design, develop, maintain and integrate some RTEMS support tools (Timeline Tool, Configuration and Management Tools), to maintain flight libraries and Board Support Packages, to develop a strong relationship with the World RTEMS Community and finally to produce some considerations in ARINC-653, DO-178B and ECSS E-40 standards. RTEMS Improvement is the continuation of the RTEMS CENTRE. Currently the RTEMS, version 4.8.0, is being facilitated for a future qualification. In this work, the validation material is being produced following the Galileo Software Standards Development Assurance Level B [5]. RTEMS is being completely tested, errors analysed, dead and deactivated code removed and tests produced to achieve 100% statement and decision coverage of source code [2]. The SW to exploit the LEON Memory Management Unit (MMU) hardware will be also added. A brief description of the expected implementations will be given.

  9. Modelling of proton acceleration in application to a ground level enhancement

    NASA Astrophysics Data System (ADS)

    Afanasiev, A.; Vainio, R.; Rouillard, A. P.; Battarbee, M.; Aran, A.; Zucca, P.

    2018-06-01

    Context. The source of high-energy protons (above 500 MeV) responsible for ground level enhancements (GLEs) remains an open question in solar physics. One of the candidates is a shock wave driven by a coronal mass ejection, which is thought to accelerate particles via diffusive-shock acceleration. Aims: We perform physics-based simulations of proton acceleration using information on the shock and ambient plasma parameters derived from the observation of a real GLE event. We analyse the simulation results to find out which of the parameters are significant in controlling the acceleration efficiency and to get a better understanding of the conditions under which the shock can produce relativistic protons. Methods: We use the results of the recently developed technique to determine the shock and ambient plasma parameters, applied to the 17 May 2012 GLE event, and carry out proton acceleration simulations with the Coronal Shock Acceleration (CSA) model. Results: We performed proton acceleration simulations for nine individual magnetic field lines characterised by various plasma conditions. Analysis of the simulation results shows that the acceleration efficiency of the shock, i.e. its ability to accelerate particles to high energies, tends to be higher for those shock portions that are characterised by higher values of the scattering-centre compression ratio rc and/or the fast-mode Mach number MFM. At the same time, the acceleration efficiency can be strengthened by enhanced plasma density in the corresponding flux tube. The simulations show that protons can be accelerated to GLE energies in the shock portions characterised by the highest values of rc. Analysis of the delays between the flare onset and the production times of protons of 1 GV rigidity for different field lines in our simulations, and a subsequent comparison of those with the observed values indicate a possibility that quasi-perpendicular portions of the shock play the main role in producing relativistic

  10. Diabetic retinopathy screening in New Zealand requires improvement: results from a multi-centre audit.

    PubMed

    Hutchins, Edward; Coppell, Kirsten J; Morris, Ainsley; Sanderson, Gordon

    2012-06-01

    To determine whether diabetic retinal screening services and retinopathy referral centres in New Zealand meet the national guidelines for referral and assessment of screen detected moderate retinal and mild macular diabetic eye disease. Diabetic retinal screening pathways and the data collected at four main centre retinal screening services were described and compared with recommendations in the national diabetes retinal screening guidelines. A retrospective audit of photoscreen detected moderate retinopathy (grade R3), and mild maculopathy (grades M2B and M3) during May to August 2008 was undertaken. Data collected by retinopathy referral centres were used to examine the follow-up of screen detected cases and to make comparisons with the national recommendations. All four screening services used the guidelines for grading, but the recommended dataset was incomplete. Not all recorded data were readily accessible. The retinal photos of 157 (2.4%) patients were graded as R3, M2B, M3 or a combination. The proportion of those screened with these grades varied across the four centres from 1.2% to 3.4%. Follow-up of the 157 screen positive patients did not always comply with guideline recommendations. Seventy five (48%) were referred for review by an ophthalmologist as recommended, 45 (60% of referred) were seen within the recommended six months. Nine patients (15% of the 60 with a documented assessment) were referred for or received laser treatment at 12-months follow-up. Quality diabetic retinal screening data systems and quality assurance programs are required to improve the monitoring and quality of retinal screening in New Zealand. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.

  11. Menopause accelerates biological aging

    PubMed Central

    Levine, Morgan E.; Lu, Ake T.; Chen, Brian H.; Hernandez, Dena G.; Singleton, Andrew B.; Ferrucci, Luigi; Bandinelli, Stefania; Salfati, Elias; Manson, JoAnn E.; Quach, Austin; Kusters, Cynthia D. J.; Kuh, Diana; Wong, Andrew; Teschendorff, Andrew E.; Widschwendter, Martin; Ritz, Beate R.; Absher, Devin; Assimes, Themistocles L.; Horvath, Steve

    2016-01-01

    Although epigenetic processes have been linked to aging and disease in other systems, it is not yet known whether they relate to reproductive aging. Recently, we developed a highly accurate epigenetic biomarker of age (known as the “epigenetic clock”), which is based on DNA methylation levels. Here we carry out an epigenetic clock analysis of blood, saliva, and buccal epithelium using data from four large studies: the Women's Health Initiative (n = 1,864); Invecchiare nel Chianti (n = 200); Parkinson's disease, Environment, and Genes (n = 256); and the United Kingdom Medical Research Council National Survey of Health and Development (n = 790). We find that increased epigenetic age acceleration in blood is significantly associated with earlier menopause (P = 0.00091), bilateral oophorectomy (P = 0.0018), and a longer time since menopause (P = 0.017). Conversely, epigenetic age acceleration in buccal epithelium and saliva do not relate to age at menopause; however, a higher epigenetic age in saliva is exhibited in women who undergo bilateral oophorectomy (P = 0.0079), while a lower epigenetic age in buccal epithelium was found for women who underwent menopausal hormone therapy (P = 0.00078). Using genetic data, we find evidence of coheritability between age at menopause and epigenetic age acceleration in blood. Using Mendelian randomization analysis, we find that two SNPs that are highly associated with age at menopause exhibit a significant association with epigenetic age acceleration. Overall, our Mendelian randomization approach and other lines of evidence suggest that menopause accelerates epigenetic aging of blood, but mechanistic studies will be needed to dissect cause-and-effect relationships further. PMID:27457926

  12. Saskatchewan's (Canada) Regional Centre of Expertise on Education for Sustainable Development

    ERIC Educational Resources Information Center

    Dahms, Tanya; McMartin, Dena; Petry, Roger

    2008-01-01

    Purpose: The purpose of this paper is to describe the unique collaborative process initiated at the University of Regina in Saskatchewan, Canada, to develop a Regional Centre of Expertise (RCE) on Education for Sustainable Development (ESD) through the United Nations University-Institute of Advanced Studies (UNU-IAS). Design/methodology/approach:…

  13. Birth centre confinement at the Queen Victoria Medical Centre. I. Obstetric and neonatal outcome.

    PubMed

    Campbell, J; Hudson, H; Lumley, J; Morris, N; Rao, J; Spensley, J

    1981-10-03

    A review of hte first 175 confinements at the Queen Victoria Medical Centre Birth Centre is presented. The design, structure and function of hte Birth Centre is described and the safety of the programme demonstrated. Seventy-four pregnancies (42%) accepted for Birth Centre confinement required transfer because of antepartum or intrapartum complications. There were satisfactory obstetric and neonatal outcomes in all pregnancies. The first year's experience has allowed a reassessment of the risk factors, which will permit greater use of the Birth Centre without any increases risk to mothers or babies.

  14. Case reports of lead poisoning in dogs from the National Animal Poison Control Center and the Centre National D'Informations Toxicologiques, Veterinaires: anecdotes or reality?

    PubMed

    Berny, P J; Cote, L M; Buck, W B

    1992-02-01

    This paper presents case reports of lead toxicoses from 2 major animal poison control centers in Europe and North America, gathered from 1985 through 1989. All results examined here involved cases assessed as "toxicosis" or "suspected toxicosis" by the National Animal Poison Control Center (NAPCC) or the Centre National d'Informations Toxicologiques Veterinaries (CNITV). 537 cases were reported to the NAPCC, most of them concerning dogs (59%). In France, most of the 362 cases involved cattle (57.2%). There was an increased number of cases reported during late summer and early fall, and a decreased number of cases in November and December, in both centers. Dogs intoxicated were predominantly young animals (60% were less than 2 years old). No sex difference was noted. Pure bred dogs appeared more often involved than mixed-breed ones, but the breed distribution closely resembles dog breed distribution in the US. The source of lead was usually unknown and, when information was available, paint seemed to be the most common cause of poisoning. Clinical signs reported to the animal poison control centers involved the CNS and GI tract. Results from the French and the American database showed similar trends. They are compared to data from veterinary clinics and veterinary colleges in the US and Australia. In each case, data are very similar to what was reported to the CNITV and the NAPCC. It is concluded that animal poison control centers databases can provide a useful tool for better knowledge of animal poisoning. They can also help identify unexpected toxicologic problems related to drug administration or pesticide use.

  15. The Search for Centre

    ERIC Educational Resources Information Center

    Nunes, April

    2006-01-01

    This paper acknowledges the importance of a dancer's centre but likewise highlights the problematic nature of the communication of this concept from dance teacher to student. After a brief introduction of orthodox approaches in finding centre, this paper suggests a method of locating centre through the ancient somatic technique.

  16. Accelerator system and method of accelerating particles

    NASA Technical Reports Server (NTRS)

    Wirz, Richard E. (Inventor)

    2010-01-01

    An accelerator system and method that utilize dust as the primary mass flux for generating thrust are provided. The accelerator system can include an accelerator capable of operating in a self-neutralizing mode and having a discharge chamber and at least one ionizer capable of charging dust particles. The system can also include a dust particle feeder that is capable of introducing the dust particles into the accelerator. By applying a pulsed positive and negative charge voltage to the accelerator, the charged dust particles can be accelerated thereby generating thrust and neutralizing the accelerator system.

  17. Contribution of cerebrovascular disease in autopsy confirmed neurodegenerative disease cases in the National Alzheimer’s Coordinating Centre

    PubMed Central

    Toledo, Jon B.; Arnold, Steven E.; Raible, Kevin; Brettschneider, Johannes; Xie, Sharon X.; Grossman, Murray; Monsell, Sarah E.; Kukull, Walter A.

    2013-01-01

    Cerebrovascular disease and vascular risk factors are associated with Alzheimer’s disease, but the evidence for their association with other neurodegenerative disorders is limited. Therefore, we compared the prevalence of cerebrovascular disease, vascular pathology and vascular risk factors in a wide range of neurodegenerative diseases and correlate them with dementia severity. Presence of cerebrovascular disease, vascular pathology and vascular risk factors was studied in 5715 cases of the National Alzheimer’s Coordinating Centre database with a single neurodegenerative disease diagnosis (Alzheimer’s disease, frontotemporal lobar degeneration due to tau, and TAR DNA-binding protein 43 immunoreactive deposits, α-synucleinopathies, hippocampal sclerosis and prion disease) based on a neuropathological examination with or without cerebrovascular disease, defined neuropathologically. In addition, 210 ‘unremarkable brain’ cases without cognitive impairment, and 280 cases with pure cerebrovascular disease were included for comparison. Cases with cerebrovascular disease were older than those without cerebrovascular disease in all the groups except for those with hippocampal sclerosis. After controlling for age and gender as fixed effects and centre as a random effect, we observed that α-synucleinopathies, frontotemporal lobar degeneration due to tau and TAR DNA-binding protein 43, and prion disease showed a lower prevalence of coincident cerebrovascular disease than patients with Alzheimer’s disease, and this was more significant in younger subjects. When cerebrovascular disease was also present, patients with Alzheimer’s disease and patients with α-synucleinopathy showed relatively lower burdens of their respective lesions than those without cerebrovascular disease in the context of comparable severity of dementia at time of death. Concurrent cerebrovascular disease is a common neuropathological finding in aged subjects with dementia, is more common in

  18. Accelerated Districts--The Next Step. A Summary of Research and Design.

    ERIC Educational Resources Information Center

    Driver, Cyrus; And Others

    The National Center for the Accelerated Schools Project at Stanford University has recognized that district-level change is necessary if changes at accelerated schools are to gain permanence and become widespread. The Center has therefore initiated a research and development project to design a set of models on which districts can reconstitute…

  19. Representing Value as Digital Object: A Discussion of Transferability and Anonymity; Digital Library Initiatives of the Deutsche Forschungsgemeinschaft; CrossRef Turns One; Fermi National Accelerator Laboratory (Fermilab).

    ERIC Educational Resources Information Center

    Kahn, Robert E.; Lyons, Patrice A.; Brahms, Ewald; Brand, Amy; van den Bergen, Mieke

    2001-01-01

    Includes four articles that discuss the use of digital objects to represent value in a network environment; digital library initiatives at the central public funding organization for academic research in Germany; an application of the Digital Object Identifier System; and the Web site of the Fermi National Accelerator Laboratory. (LRW)

  20. New Targets for New Accelerators

    NASA Astrophysics Data System (ADS)

    Frentz, Bryce; Manukyan, Khachatur; Aprahamian, Ani

    2013-10-01

    New accelerators, such as the 5 MV Sta Ana accelerator at the University of Notre Dame, will produce more powerful beams up to 100's of μAmps. These accelerators require a complete rethinking of target preparation since the high intensity of such beams would melt conventional targets. Traditionally, accelerator targets are made with a tantalum backing because of its high atomic mass. However, tantalum is brittle, a poor conductor, and, if produced commercially, often contains impurities (e.g. fluorine) that produce undesirable background and reaction products. Tungsten, despite its brittle structure and poor conductivity, has a high atomic mass and lacks impurities, making it a more desirable backing. In conjunction with tungsten's properties, copper is robust and a far superior thermal conductor. We describe a new method of reactive joining that we developed for creating targets that use the advantageous properties of both tungsten and copper. This process involved placing a reactive mixture between tungsten and copper and applying a load force. The mixture is then ignited, and while under pressure, the system produces conditions to join the materials. We present our investigation to optimize the process of reactive joining, as well as some of the final target's properties. This work was supported by the National Science Foundation under Grant PHY-1068192.

  1. The impact of distance and duration of travel on participation rates and participants' satisfaction: results from a pilot study at one study centre in Pretest 2 of the German National Cohort.

    PubMed

    Schweitzer, Aparna; Akmatov, Manas K; Kindler, Florentina; Kemmling, Yvonne; Kreienbrock, Lothar; Krause, Gérard; Pessler, Frank

    2015-08-21

    In this pilot study within the Pretest 2 phase of the German National Cohort, we aimed to (1) test the hypothesis that distance and duration of travel to a study centre may affect participation rates and participants' satisfaction and (2) to obtain data that would help to select recruitment areas around the study centre Hannover with the greatest projected participation rate for the main study. Mixed urban/suburban environment in Northern Germany with approximately 600,000 inhabitants. 4 recruitment areas with divergent estimated mean distances (range, 7-40 km) and duration of travel to the study centre Hannover were selected. 1050 men and women (ratio, 1:1), aged 20-69 years, were randomly selected from the population registries of the 4 recruitment areas and invited by mail to participate in the Pretest 2 study programme at the study centre Hannover, covering a variety of questionnaire-based and physical assessments. 166 individuals participated (16%). All 166 participants completed a travel questionnaire containing 5 items relating to travel duration and satisfaction, amounting to a participation rate of 100% in the questionnaire-based part of the study. Participation rates in the Pretest 2 programme at the study centre Hannover by area ranged from 11% (area farthest from the study centre, estimated median distance 38 km) to 18% (nearest area, 2 km). The odds of non-participation were highest in the area farthest from the study centre (adjusted OR 2.06; p=0.01; CI 1.28 to 3.32). Nonetheless, 97% of participants were satisfied with travel duration. Increasing distance was associated with a lower participation rate. However, acceptance of duration of travel was high, irrespective of distance or duration. Thus, recruiting in farther away locations may select individuals with a greater frustration tolerance for travel to the study centre, perhaps due to a greater interest in participating in health-oriented studies and thus different health-related behaviour

  2. [The design and development of a quality system for the diagnosis of exotic animal diseases at the National Centre for Animal and Plant Health in Cuba].

    PubMed

    de Oca, N Montes; Villoch, A; Pérez Ruano, M

    2004-12-01

    A quality system for the diagnosis of exotic animal diseases was developed at the national centre for animal and plant health (CENSA), responsible for coordinating the clinical, epizootiological and laboratory diagnosis of causal agents of exotic animal diseases in Cuba. A model was designed on the basis of standard ISO 9001:2000 of the International Organization for Standardization (ISO), standard ISO/IEC 17025:1999 of ISO and the International Electrotechnical Commission, recommendations of the World Organisation for Animal Health (OIE) and other regulatory documents from international and national organisations that deal specifically with the treatment of emerging diseases. Twenty-nine standardised operating procedures were developed, plus 13 registers and a checklist to facilitate the evaluation of the system. The effectiveness of the quality system was confirmed in the differential diagnosis of classical swine fever at an animal virology laboratory in Cuba.

  3. Pertussis diagnosis in Belgium: results of the National Reference Centre for Bordetella anno 2015.

    PubMed

    Martini, H; Rodeghiero, C; VAN DEN Poel, C; Vincent, M; Pierard, D; Huygen, K

    2017-08-01

    In 2015, the Belgian National Reference Centre for Bordetella analyzed 4110 respiratory samples by qPCR and 4877 serum samples by serology. Whereas about 50% of respiratory samples were from infants and children below the age of five, serum samples were distributed among all age categories. A total of 394 (9·6%) cases was diagnosed as positive for Bordetella pertussis by qPCR and 844 (17·3%) cases were diagnosed as acute infection by serology (anti-pertussis toxin (PT) IgG > 125 IU/ml). Another 1042 (21·4%) sera had anti-PT IgG between 55 and 125 IU/ml reflecting a vaccination or pertussis infection during the last 1-2 years. Seventy per cent of the pertussis cases diagnosed by qPRC were in infants and children younger than 14 years old, whereas the highest number of sera with anti-PT levels >125 IU/ml was in the age group of 10-14 years old. Based on the limited data of the last vaccination (reported for only 15% of the samples), recent booster vaccination in the teenager group may have contributed only minimally to these elevated anti-PT levels. The highest number of sera with anti-PT titers between 55 and 125 IU/ml was found in the age category 50-59 years old. It is clear that pertussis continues to be a problem in Belgium and that other vaccination strategies (maternal vaccination, cocoon vaccination) and ultimately better vaccines will be needed to control this highly infectious respiratory disease.

  4. Rayleigh-Taylor mixing with space-dependent acceleration

    NASA Astrophysics Data System (ADS)

    Abarzhi, Snezhana

    2016-11-01

    We extend the momentum model to describe Rayleigh-Taylor (RT) mixing driven by a space-dependent acceleration. The acceleration is a power-law function of space coordinate, similarly to astrophysical and plasma fusion applications. In RT flow the dynamics of a fluid parcel is driven by a balance per unit mass of the rates of momentum gain and loss. We find analytical solutions in the cases of balanced and imbalanced gains and losses, and identify their dependence on the acceleration exponent. The existence is shown of two typical sub-regimes of self-similar RT mixing - the acceleration-driven Rayleigh-Taylor-type mixing and dissipation-driven Richtymer-Meshkov-type mixing with the latter being in general non-universal. Possible scenarios are proposed for transitions from the balanced dynamics to the imbalanced self-similar dynamics. Scaling and correlations properties of RT mixing are studied on the basis of dimensional analysis. Departures are outlined of RT dynamics with space-dependent acceleration from canonical cases of homogeneous turbulence as well as blast waves with first and second kind self-similarity. The work is supported by the US National Science Foundation.

  5. Translating change: the development of a person-centred triage training programme for emergency nurses.

    PubMed

    McBrien, Barry

    2009-01-01

    Within health care, there has been a change in practice from an illness-orientated service to one that is more health-focused and person-centred. The concept of person-centredness is frequently espoused by practitioners as being not only a desirable, but a necessary element of health care provision. Indeed, nationally and internationally, person-centred care has underpinned many healthcare documents and policies. Person-centred practice focuses on providing care, utilising a variety of processes that operationalise person-centred nursing and include working with patients' beliefs and values, engagement, presence, sharing decision-making and providing for physical needs. In the field of emergency nursing, the incorporation of person-centred care and its holistic foundation may require a significant shift in practice. There is evidence to suggest that emergency nurses view their role as one, which is predominantly concerned with providing urgent physical care, rather than one, which espouses the theories of holistic healthcare. To this extent, being person-centred in the context of emergency care, requires the nurse to move beyond the traditional notions of his/her role and to embrace the more holistic aspects of patient care. The aim of this article is to critically analyse how a change in nurse-led triage training in one Irish Emergency Department facilitated an improved person-centred approach in practice.

  6. Expanding Capacity With an Accelerated On-Line BSN Program.

    PubMed

    Lindley, Marie Kelly; Ashwill, Regina; Cipher, Daisha J; Mancini, Mary E

    Colleges of nursing are challenged to identify innovative, efficient, and effective mechanisms to expand enrollment in prelicensure programs. This objective of this project was to identify whether a prelicensure nursing program that is both accelerated and on-line is as effective as a traditional face-to-face program, in terms of graduation rates and National Council Licensure Exam pass rates. This analysis of 1,064 students compared demographic and outcomes data between students in a state university's college of nursing who were enrolled in an accelerated, fully on-line bachelors of science in nursing (BSN) program and the traditional on-campus BSN program. Students significantly differed in their ethnicity, level of prior education, and graduation rates (95% vs. 89.3%). First-time National Council Licensure Exam pass rates for both groups did not significantly differ (92.5% vs. 94.5%). Results indicate that an accelerated on-line BSN program can overcome factors known to limit capacity expansion in schools of nursing and produce high-quality student outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Plasma wakefield acceleration experiments at FACET II

    NASA Astrophysics Data System (ADS)

    Joshi, C.; Adli, E.; An, W.; Clayton, C. E.; Corde, S.; Gessner, S.; Hogan, M. J.; Litos, M.; Lu, W.; Marsh, K. A.; Mori, W. B.; Vafaei-Najafabadi, N.; O'shea, B.; Xu, Xinlu; White, G.; Yakimenko, V.

    2018-03-01

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the ‘blow-out regime’ have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currently under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. We then briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.

  8. Plasma wakefield acceleration experiments at FACET II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, C.; Adli, E.; An, W.

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the 'blow-out regime' have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currentlymore » under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. Here, we briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.« less

  9. Plasma wakefield acceleration experiments at FACET II

    DOE PAGES

    Joshi, C.; Adli, E.; An, W.; ...

    2018-01-12

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the 'blow-out regime' have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currentlymore » under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. Here, we briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.« less

  10. UK Renal Registry 16th annual report: chapter 10 haemoglobin, ferritin and erythropoietin amongst UK adult dialysis patients in 2012: national and centre-specific analyses.

    PubMed

    Rao, Anirudh; Gilg, Julie; Williams, Andrew

    2013-01-01

    Anaemia treatment in chronic kidney disease (CKD) patients has changed dramatically since the implementation of erythropoietin stimulating agents (ESAs) and has shifted the emphasis from treating severe anaemia in dialysis patients to preventing anaemia. The aim of this chapter is to determine the extent to which the UK Renal Association (RA) and National Institute for Health and Care Excellence (NICE) guidelines for anaemia management are met in the UK. Quarterly data were obtained for haemoglobin (Hb) and factors that influence Hb from UK renal centres for the incident and prevalent renal replacement therapy (RRT) cohorts for 2012. In the UK, in 2012, 51% of patients commenced dialysis therapy with Hb 100 g/L (median Hb 100 g/L). Of patients in the early presentation group, 54% started dialysis with Hb 100 g/L whilst 34% of patients presenting late started dialysis with Hb 100 g/L. The UK median Hb of haemodialysis (HD) patients was 112 g/L, with 82% of patients having Hb 100 g/L. The median Hb of peritoneal dialysis (PD) patients in the UK was 114 g/L, with 85% of patients having Hb 100 g/L. The median ferritin in HD patients in the UK was 431 µg/L and 95% of HD patients had a ferritin 100 µg/L. In EW&NI the median ferritin in PD patients was 285 µg/L (IQR 164-466) with 88% of PD patients having a ferritin 100 µg/L. In EW&NI the median ESA dose was higher for HD than PD patients (7,248 vs. 4,250 IU/week). The percentage of patients treated with an ESA and having Hb >120 g/L ranged between centres from 7-39% for HD and from 0-33% for PD. There was poor correlation between median Hb achieved and median ferritin and ESA usage across the EW&NI centres. There was also a significant variation between centres in the percentages of patients treated with an ESA and having Hb >120 g/L. © 2014 S. Karger AG, Basel.

  11. Do ungulates accelerate or decelerate nitrogen cycling?

    USGS Publications Warehouse

    Singer, F.J.; Schoenecker, K.A.

    2003-01-01

    Nitrogen (N) is an essential nutrient for plants and animals, and N may be limiting in many western US grassland and shrubland ungulate winter ranges. Ungulates may influence N pools and they may alter N inputs and outputs (losses) to the ecosystem in a number of ways. In this paper we compare the ecosystem effects of ungulate herbivory in two western national parks, Rocky Mountain National Park (RMNP), Colorado, and Yellowstone National Park (YNP), Wyoming. We compare ungulate herbivory effects on N pools, N fluxes, N yields, and plant productivity in the context of the accelerating and decelerating nutrient cycling scenarios [Ecology 79 (1998) 165]. We concluded that the YNP grasslands fit the accelerating nutrient cycling scenario for ungulate herbivory: in response to grazing, grassland plant species abundance was largely unaltered, net annual aboveground primary productivity (NAPP) was stimulated (except during drought), consumption of key N-rich forages by ungulates was moderate and their abundance was sustained, soil N mineralization rates doubled, N pools increased, aboveground N yield increased, and N concentrations increased in most grassland plant species. Grazing in grasslands in RMNP resulted in no consistent detectable acceleration or deceleration of nutrient cycling. Grazing effects in short willow and aspen vegetation types in RMNP fit the decelerating nutrient cycling scenario of Ritchie et al. [Ecology 79 (1998) 165]. Key N-rich forages declined due to herbivory (willows, aspen, herbaceous vegetation). Aboveground production declined, soil N mineralization rates declined, N pools declined (NO3− pools were 30% that of ungrazed controls), and aboveground N yield declined. We believe that the higher ungulate densities and rates of plant consumption in RMNP, large declines in N-rich forage plants, and possibly a tendency of ungulates to move N from willow and aspen vegetation types to other types in RMNP, contributed to deceleration of nutrient

  12. Drive Beam Shaping and Witness Bunch Generation for the Plasma Wakefield Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    England, R. J.; Frederico, J.; Hogan, M. J.

    2010-11-04

    High transformer ratio operation of the plasma wake field accelerator requires a tailored drive beam current profile followed by a short witness bunch. We discuss techniques for generating the requisite dual bunches and for obtaining the desired drive beam profile, with emphasis on the FACET experiment at SLAC National Accelerator Laboratory.

  13. An accelerating high-latitude jet in Earth's core

    NASA Astrophysics Data System (ADS)

    Finlay, C. C.; Livermore, P. W.; Hollerbach, R.

    2016-12-01

    The structure of the core-generated magnetic field, and how it changes in time (its secular variation or SV), supplies an invaluable constraint on the dynamics of the outer core. At high latitude, previous studies have noted distinctive behaviour of secular change, in particular suggesting a polar vortex tied to the dynamics within the tangent cylinder region. Recent high-resolution observational models that include data from the Swarm satellites have refined the structure of observed SV, to a rapidly changing circular daisy-chain configuration centred on the north geographic pole, on or very close to the tangent cylinder itself. Motivated by theoretical considerations of the likely dynamical regime of the core, we demonstrate that this feature can be explained by a localised westwards cylindrical jet of 420 km width centred the tangent cylinder, whose amplitude appears to have increased in strength by a factor of three over the period 2000-2016 to about 40 km/yr. The current accelerating phase may be a short fragment of decadal fluctuations of the jet strength linked to both torsional wave activity and the rotation direction of the inner core.

  14. Accelerated Reader and Young People's Reading in 2013: Findings from the National Literacy Trust's 2013 Annual Literacy Survey on Reading Enjoyment, Reading Behaviour outside Class and Reading Attitudes

    ERIC Educational Resources Information Center

    Clark, Christina

    2014-01-01

    Accelerated Reader (AR) is a tool for monitoring and managing independent reading practice. Although a wealth of data is routinely collected about children's reading skills as part of the AR tool, no information is collected on the "softer" reading outcomes, such as reading enjoyment and attitudes towards reading. The National Literacy…

  15. Determination of the centre of mass kinematics in alpine skiing using differential global navigation satellite systems.

    PubMed

    Gilgien, Matthias; Spörri, Jörg; Chardonnens, Julien; Kröll, Josef; Limpach, Philippe; Müller, Erich

    2015-01-01

    In the sport of alpine skiing, knowledge about the centre of mass (CoM) kinematics (i.e. position, velocity and acceleration) is essential to better understand both performance and injury. This study proposes a global navigation satellite system (GNSS)-based method to measure CoM kinematics without restriction of capture volume and with reasonable set-up and processing requirements. It combines the GNSS antenna position, terrain data and the accelerations acting on the skier in order to approximate the CoM location, velocity and acceleration. The validity of the method was assessed against a reference system (video-based 3D kinematics) over 12 turn cycles on a giant slalom skiing course. The mean (± s) position, velocity and acceleration differences between the CoM obtained from the GNSS and the reference system were 9 ± 12 cm, 0.08 ± 0.19 m · s(-1) and 0.22 ± 1.28 m · s(-2), respectively. The velocity and acceleration differences obtained were smaller than typical differences between the measures of several skiers on the same course observed in the literature, while the position differences were slightly larger than its discriminative meaningful change. The proposed method can therefore be interpreted to be technically valid and adequate for a variety of biomechanical research questions in the field of alpine skiing with certain limitations regarding position.

  16. From Comfort Zone to Contact Zone Lessons from a Belfast Writing Centre

    ERIC Educational Resources Information Center

    Cain, Kathleen Shine

    2011-01-01

    American writing center director Kathleen Shine Cain analyzes the transformative experience of spending a year in a Belfast writing centre, resulting in a renewed appreciation of cross-national and cross-cultural partnerships. Although American writing center theory and pedagogy have informed the development of centers in Europe, Asia, and Africa,…

  17. After-School Centres: Statistical Information and Monitoring of the Economics of Education

    ERIC Educational Resources Information Center

    Kupriyanov, B. V.; Kosaretsky, S. G.; Mertsalova, T. A.; Semenova, T. V.

    2015-01-01

    This article presents results of a survey of after-school centre directors concerning the extracurricular activities of children. It was conducted within the framework of the Monitoring of the Economics of Education at the National Research University--Higher School of Economics (HSE). The demographics of students at children's after-school…

  18. Effects of unstratified and centre-stratified randomization in multi-centre clinical trials.

    PubMed

    Anisimov, Vladimir V

    2011-01-01

    This paper deals with the analysis of randomization effects in multi-centre clinical trials. The two randomization schemes most often used in clinical trials are considered: unstratified and centre-stratified block-permuted randomization. The prediction of the number of patients randomized to different treatment arms in different regions during the recruitment period accounting for the stochastic nature of the recruitment and effects of multiple centres is investigated. A new analytic approach using a Poisson-gamma patient recruitment model (patients arrive at different centres according to Poisson processes with rates sampled from a gamma distributed population) and its further extensions is proposed. Closed-form expressions for corresponding distributions of the predicted number of the patients randomized in different regions are derived. In the case of two treatments, the properties of the total imbalance in the number of patients on treatment arms caused by using centre-stratified randomization are investigated and for a large number of centres a normal approximation of imbalance is proved. The impact of imbalance on the power of the study is considered. It is shown that the loss of statistical power is practically negligible and can be compensated by a minor increase in sample size. The influence of patient dropout is also investigated. The impact of randomization on predicted drug supply overage is discussed. Copyright © 2010 John Wiley & Sons, Ltd.

  19. UK Renal Registry 16th annual report: chapter 9 adequacy of haemodialysis in UK adult patients in 2012: national and centre-specific analyses.

    PubMed

    Shaw, Catriona; Steenkamp, Retha; Davenport, Andrew

    2013-01-01

    Outcomes in patients treated with haemodialysis (HD) are influenced by the delivered dose of dialysis. The UK Renal Association (RA) publishes clinical practice guidelines which include recommendations for dialysis dose. The urea reduction ratio (URR) is a widely used measure of dialysis dose and has historically been the measure of adequacy reported by the UKRR. This chapter aims to determine the extent to which patients achieved the recommended UK target. All 71 UK renal centres submitted data to the UK Renal Registry (UKRR). Two groups of patients were included in the analyses: the prevalent HD patient population on 30st September 2012 and the incident HD patient population for 2011. Centres returning data on <50% of their patient population or centres with <20 patients were excluded from centrespecific comparisons. Data regarding URR were available from 63 renal centres in the UK. Forty nine centres provided URR data on more than 90% of prevalent HD patients. The proportion of patients in the UK who met the UK clinical practice guideline for URR (>65%) increased from 69% in 2000 to 88% in 2012. There was persistent variation observed between centres, with 21 centres attaining the RA clinical practice guideline in >90% of patients, 38 centres attaining the guideline in 70-90% of patients and one centre in less than 70% of patients. The overall proportion of prevalent HD patients with a URR >65% has continued to improve over time. The delivered dose of HD, as measured by URR for patients with established renal failure, has increased over the last decade. Whilst the majority of UK patients achieved the target URR there was considerable variation between centres in the percentage of patients achieving the current guideline. © 2014 S. Karger AG, Basel.

  20. Defining and describing birth centres in the Netherlands - a component study of the Dutch Birth Centre Study.

    PubMed

    Hermus, M A A; Boesveld, I C; Hitzert, M; Franx, A; de Graaf, J P; Steegers, E A P; Wiegers, T A; van der Pal-de Bruin, K M

    2017-07-03

    During the last decade, a rapid increase of birth locations for low-risk births, other than conventional obstetric units, has been seen in the Netherlands. Internationally some of such locations are called birth centres. The varying international definitions for birth centres are not directly applicable for use within the Dutch obstetric system. A standard definition for a birth centre in the Netherlands is lacking. This study aimed to develop a definition of birth centres for use in the Netherlands, to identify these centres and to describe their characteristics. International definitions of birth centres were analysed to find common descriptions. In July 2013 the Dutch Birth Centre Questionnaire was sent to 46 selected Dutch birth locations that might qualify as birth centre. Questions included: location, reason for establishment, women served, philosophies, facilities that support physiological birth, hotel-facilities, management, environment and transfer procedures in case of referral. Birth centres were visited to confirm the findings from the Dutch Birth Centre Questionnaire and to measure distance and time in case of referral to obstetric care. From all 46 birth locations the questionnaires were received. Based on this information a Dutch definition of a birth centre was constructed. This definition reads: "Birth centres are midwifery-managed locations that offer care to low risk women during labour and birth. They have a homelike environment and provide facilities to support physiological birth. Community midwives take primary professional responsibility for care. In case of referral the obstetric caregiver takes over the professional responsibility of care." Of the 46 selected birth locations 23 fulfilled this definition. Three types of birth centres were distinguished based on their location in relation to the nearest obstetric unit: freestanding (n = 3), alongside (n = 14) and on-site (n = 6). Transfer in case of referral was necessary for all

  1. Multi-MW accelerator target material properties under proton irradiation at Brookhaven National Laboratory linear isotope producer

    DOE PAGES

    Simos, N.; Ludewig, H.; Kirk, H.; ...

    2018-05-29

    The effects of proton beams irradiating materials considered for targets in high-power accelerator experiments have been studied using the Brookhaven National Laboratory’s (BNL) 200 MeV proton linac. A wide array of materials and alloys covering a wide range of the atomic number (Z) are being scoped by the high-power accelerator community prompting the BNL studies to focus on materials representing each distinct range, i.e. low-Z, mid-Z and high-Z. The low range includes materials such as beryllium and graphite, the midrange alloys such as Ti-6Al-4V, gum metal and super-Invar and finally the high-Z range pure tungsten and tantalum. Of interest inmore » assessing proton irradiation effects are (a) changes in physiomechanical properties which are important in maintaining high-power target functionality, (b) identification of possible limits of proton flux or fluence above which certain materials cease to maintain integrity, (c) the role of material operating temperature in inducing or maintaining radiation damage reversal, and (d) phase stability and microstructural changes. The paper presents excerpt results deduced from macroscopic and microscopic post-irradiation evaluation (PIE) following several irradiation campaigns conducted at the BNL 200 MeV linac and specifically at the isotope producer beam-line/target station. The microscopic PIE relied on high energy x-ray diffraction at the BNL NSLS X17B1 and NSLS II XPD beam lines. The studies reveal the dramatic effects of irradiation on phase stability in several of the materials, changes in physical properties and ductility loss as well as thermally induced radiation damage reversal in graphite and alloys such as super-Invar.« less

  2. Multi-MW accelerator target material properties under proton irradiation at Brookhaven National Laboratory linear isotope producer

    NASA Astrophysics Data System (ADS)

    Simos, N.; Ludewig, H.; Kirk, H.; Dooryhee, E.; Ghose, S.; Zhong, Z.; Zhong, H.; Makimura, S.; Yoshimura, K.; Bennett, J. R. J.; Kotsinas, G.; Kotsina, Z.; McDonald, K. T.

    2018-05-01

    The effects of proton beams irradiating materials considered for targets in high-power accelerator experiments have been studied using the Brookhaven National Laboratory's (BNL) 200 MeV proton linac. A wide array of materials and alloys covering a wide range of the atomic number (Z) are being scoped by the high-power accelerator community prompting the BNL studies to focus on materials representing each distinct range, i.e. low-Z, mid-Z and high-Z. The low range includes materials such as beryllium and graphite, the midrange alloys such as Ti-6Al-4V, gum metal and super-Invar and finally the high-Z range pure tungsten and tantalum. Of interest in assessing proton irradiation effects are (a) changes in physiomechanical properties which are important in maintaining high-power target functionality, (b) identification of possible limits of proton flux or fluence above which certain materials cease to maintain integrity, (c) the role of material operating temperature in inducing or maintaining radiation damage reversal, and (d) phase stability and microstructural changes. The paper presents excerpt results deduced from macroscopic and microscopic post-irradiation evaluation (PIE) following several irradiation campaigns conducted at the BNL 200 MeV linac and specifically at the isotope producer beam-line/target station. The microscopic PIE relied on high energy x-ray diffraction at the BNL NSLS X17B1 and NSLS II XPD beam lines. The studies reveal the dramatic effects of irradiation on phase stability in several of the materials, changes in physical properties and ductility loss as well as thermally induced radiation damage reversal in graphite and alloys such as super-Invar.

  3. Multi-MW accelerator target material properties under proton irradiation at Brookhaven National Laboratory linear isotope producer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simos, N.; Ludewig, H.; Kirk, H.

    The effects of proton beams irradiating materials considered for targets in high-power accelerator experiments have been studied using the Brookhaven National Laboratory’s (BNL) 200 MeV proton linac. A wide array of materials and alloys covering a wide range of the atomic number (Z) are being scoped by the high-power accelerator community prompting the BNL studies to focus on materials representing each distinct range, i.e. low-Z, mid-Z and high-Z. The low range includes materials such as beryllium and graphite, the midrange alloys such as Ti-6Al-4V, gum metal and super-Invar and finally the high-Z range pure tungsten and tantalum. Of interest inmore » assessing proton irradiation effects are (a) changes in physiomechanical properties which are important in maintaining high-power target functionality, (b) identification of possible limits of proton flux or fluence above which certain materials cease to maintain integrity, (c) the role of material operating temperature in inducing or maintaining radiation damage reversal, and (d) phase stability and microstructural changes. The paper presents excerpt results deduced from macroscopic and microscopic post-irradiation evaluation (PIE) following several irradiation campaigns conducted at the BNL 200 MeV linac and specifically at the isotope producer beam-line/target station. The microscopic PIE relied on high energy x-ray diffraction at the BNL NSLS X17B1 and NSLS II XPD beam lines. The studies reveal the dramatic effects of irradiation on phase stability in several of the materials, changes in physical properties and ductility loss as well as thermally induced radiation damage reversal in graphite and alloys such as super-Invar.« less

  4. Centre for Education, Training, & Research in Renewable Energy and Energy Efficiency (CETREE) of Malaysia: Educating the Nation

    NASA Astrophysics Data System (ADS)

    Ibrahim, Kamarulazizi; Hilme, Khairur Rahim Ahmad

    2007-10-01

    Centre for Education, Training, and Research in Renewable Energy and Energy Efficiency (CETREE), was established in the year 2000, in Universiti Sains Malaysia (USM). CETREE is a not-for-profit organization that was part of the Malaysian Government's continuous effort in promoting sustainable development. The centre's main task is to tackle issues and problems that are slowing the potential growth of RE & EE utilizations in Malaysia. CETREE and the Government of Malaysia, with funding and supports from Danish International Development Assistance (DANIDA) and USM, has been working together closely in applying trans-disciplinary educational methods and approaches for the teaching of RE & EE that are compatible with Malaysian. Through association with various entities such as Energy Centre of Malaysia (PTM), Energy Commission of Malaysia (ST), Malaysia Electricity Supply Industry Trust Account (MESITA); CETREE was able to successfully promote sustainable development through education and training. Significant accomplishments made by CETREE include introducing RE and EE as part of Malaysian secondary schools and universities education; conducting energy related courses for professionals; and generating awareness via campaign in the mass media and CETREE's mobile-exhibition-unit road-tour.

  5. Accelerator-driven Medical Sterilization to Replace Co-60 Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroc, Thomas K.; Thangaraj, Jayakar C.T.; Penning, Richard T.

    This report documents the results of a study prepared at the request of the Office of Radiological Security of the National Nuclear Security Administration (NNSA), as part of the Domestic Protect and Reduce mission by the Illinois Accelerator Research Center (IARC) of Fermi National Accelerator Laboratory. The study included a literature survey of over 80 relevant documents and articles including industry standards, regulatory documents, technical papers, a court case, previous task force reports and industry white papers. The team also conducted interviews or had conversations with over 40 individuals representing over a dozen organizations over the course of its 10-monthmore » program. This report summarizes our findings, addresses the specific questions posed to us by NNSA, and concludes with a list of actionable recommendations.« less

  6. Integrating public health and medical intelligence gathering into homeland security fusion centres.

    PubMed

    Lenart, Brienne; Albanese, Joseph; Halstead, William; Schlegelmilch, Jeffrey; Paturas, James

    Homeland security fusion centres serve to gather, analyse and share threat-related information among all levels of governments and law enforcement agencies. In order to function effectively, fusion centres must employ people with the necessary competencies to understand the nature of the threat facing a community, discriminate between important information and irrelevant or merely interesting facts and apply domain knowledge to interpret the results to obviate or reduce the existing danger. Public health and medical sector personnel routinely gather, analyse and relay health-related inform-ation, including health security risks, associated with the detection of suspicious biological or chemical agents within a community to law enforcement agencies. This paper provides a rationale for the integration of public health and medical personnel in fusion centres and describes their role in assisting law enforcement agencies, public health organisations and the medical sector to respond to natural or intentional threats against local communities, states or the nation as a whole.

  7. Informing Policy and Practice in Australia's Vocational Education and Training Sector: Reflections and Futures. Proceedings of the 25th Anniversary Forum of the National Centre for Vocational Education Research (Adelaide, South Australia, Australia, March 21, 2007)

    ERIC Educational Resources Information Center

    Curtin, Penelope, Ed.; Loveder, Phil, Ed.

    2007-01-01

    To mark the occasion of its 25th anniversary, the National Centre for Vocational Education Research (NCVER) brought together policy, industry and academic leaders to reflect on the role that research and statistics have played in the development of Australia's vocational education and training (VET) sector. This publication includes the original…

  8. Effects of acceleration rate on Rayleigh-Taylor instability in elastic-plastic materials

    NASA Astrophysics Data System (ADS)

    Banerjee, Arindam; Polavarapu, Rinosh

    2016-11-01

    The effect of acceleration rate in the elastic-plastic transition stage of Rayleigh-Taylor instability in an accelerated non-Newtonian material is investigated experimentally using a rotating wheel experiment. A non-Newtonian material (mayonnaise) was accelerated at different rates by varying the angular acceleration of a rotating wheel and growth patterns of single mode perturbations with different combinations of amplitude and wavelength were analyzed. Experiments were run at two different acceleration rates to compare with experiments presented in prior years at APS DFD meetings and the peak amplitude responses are captured using a high-speed camera. Similar to the instability acceleration, the elastic-plastic transition acceleration is found to be increasing with increase in acceleration rate for a given amplitude and wavelength. The experimental results will be compared to various analytical strength models and prior experimental studies using Newtonian fluids. Authors acknowledge funding support from Los Alamos National Lab subcontract(370333) and DOE-SSAA Grant (DE-NA0001975).

  9. High gradient tests of metallic mm-wave accelerating structures

    DOE PAGES

    Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon; ...

    2017-05-10

    This study explores the physics of vacuum rf breakdowns in high gradient mm-wave accelerating structures. We performed a series of experiments with 100 GHz and 200 GHz metallic accelerating structures, at the Facility for Advanced Accelerator Experimental Tests (FACET) at the SLAC National Accelerator Laboratory. This paper presents the experimental results of rf tests of 100 GHz travelling-wave accelerating structures, made of hard copper-silver alloy. The results are compared with pure hard copper structures. The rf fields were excited by the FACET ultra-relativistic electron beam. The accelerating structures have open geometries, 10 cm long, composed of two halves separated bymore » a variable gap. The rf frequency of the fundamental accelerating mode depends on the gap size and can be changed from 90 GHz to 140 GHz. The measured frequency and pulse length are consistent with our simulations. When the beam travels off-axis, a deflecting field is induced in addition to the decelerating longitudinal field. We measured the deflecting forces by observing the displacement of the electron bunch and used this measurement to verify the expected accelerating gradient. We present the first quantitative measurement of rf breakdown rates in 100 GHz copper-silver accelerating structure, which was 10 –3 per pulse, with peak electric field of 0.42 GV/m, an accelerating gradient of 127 MV/m, at a pulse length of 2.3 ns. The goal of our studies is to understand the physics of gradient limitations in order to increase the energy reach of future accelerators.« less

  10. High gradient tests of metallic mm-wave accelerating structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon

    This study explores the physics of vacuum rf breakdowns in high gradient mm-wave accelerating structures. We performed a series of experiments with 100 GHz and 200 GHz metallic accelerating structures, at the Facility for Advanced Accelerator Experimental Tests (FACET) at the SLAC National Accelerator Laboratory. This paper presents the experimental results of rf tests of 100 GHz travelling-wave accelerating structures, made of hard copper-silver alloy. The results are compared with pure hard copper structures. The rf fields were excited by the FACET ultra-relativistic electron beam. The accelerating structures have open geometries, 10 cm long, composed of two halves separated bymore » a variable gap. The rf frequency of the fundamental accelerating mode depends on the gap size and can be changed from 90 GHz to 140 GHz. The measured frequency and pulse length are consistent with our simulations. When the beam travels off-axis, a deflecting field is induced in addition to the decelerating longitudinal field. We measured the deflecting forces by observing the displacement of the electron bunch and used this measurement to verify the expected accelerating gradient. We present the first quantitative measurement of rf breakdown rates in 100 GHz copper-silver accelerating structure, which was 10 –3 per pulse, with peak electric field of 0.42 GV/m, an accelerating gradient of 127 MV/m, at a pulse length of 2.3 ns. The goal of our studies is to understand the physics of gradient limitations in order to increase the energy reach of future accelerators.« less

  11. The Last Word: An Interview with Gene Chasin, CEO of Accelerated Schools Plus

    ERIC Educational Resources Information Center

    Siegle, Del

    2006-01-01

    This article presents an interview with Gene Chasin, CEO of Accelerated Schools Plus. Chasin discusses changing schools and improving student achievement. Accelerated Schools is a national endeavor that is designed to transform whole school communities. It views the community as being much broader. It includes students, teachers, parents, other…

  12. Innovation and the English National Health Service: a qualitative study of the independent sector treatment centre programme.

    PubMed

    Turner, Simon; Allen, Pauline; Bartlett, Will; Pérotin, Virginie

    2011-08-01

    Over the past two decades, an international trend of exposing public health services to different forms of economic organisation has emerged. In the English National Health Service (NHS), care is currently provided through a quasi-market including 'diverse' providers from the private and third sector. The predominant scheme through which private sector companies have been awarded NHS contracts is the Independent Sector Treatment Centre (ISTC) programme. ISTCs were designed to produce innovative models of service delivery for elective care and stimulate innovation among incumbent NHS providers. This paper investigates these claims using qualitative data on the impact of an ISTC upon a local health economy (LHE) composed of NHS organisations in England. Using the case of elective orthopaedic surgery, we conducted semi-structured interviews with senior managers from incumbent NHS providers and an ISTC in 2009. We show that ISTCs exhibit a different relationship with frontline clinicians because they counteract the power of professional communities associated with the NHS. This has positive and negative consequences for innovation. ISTCs have introduced new routines unencumbered by the extant norms of professional communities, but they appear to represent weaker learning environments and do not reproduce cooperation across organisational boundaries to the same extent as incumbent NHS providers. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Birth centre confinement at the Queen Victoria Medical Centre: four years' experience.

    PubMed

    Morris, N; Campbell, J; Biro, M A; Lumley, J; Rao, J; Spensley, J

    1986-06-09

    A review of the first four years of the functioning of the birth centre at the Queen Victoria Medical Centre is presented. In that time, 1040 pregnant women were accepted for confinement there. Of these, 52 withdrew for non-obstetric reasons, while 470 were transferred to alternative obstetrical care--274 because of antepartum complications and 196 because of intrapartum problems. Therefore, 518 women were delivered in the birth centre. The care of the women is entrusted almost entirely to a team of midwives and this review demonstrates an enviable safety record.

  14. Showing Your Pride: A National Survey of Queer Student Centres in Canadian Colleges and Universities

    ERIC Educational Resources Information Center

    Ecker, John; Rae, Jennifer; Bassi, Amandeep

    2015-01-01

    The presence of queer student centres (QSCs) across Canadian universities and colleges is largely unknown. It is an important area of investigation since queer-identified students have previously identified several benefits of these services, including receiving support from other queer individuals. The focus of the current study was to determine…

  15. NREL National Bioenergy Center Overview

    ScienceCinema

    Foust, Thomas; Pienkos, Phil; Sluiter, Justin; Magrini, Kim; McMillan, Jim

    2018-01-16

    The demand for clean, sustainable, secure energy is growing... and the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) is answering the call. NREL's National Bioenergy Center is pioneering biofuels research and development and accelerating the pace these technologies move into the marketplace.

  16. Out-of-pocket expenditure and catastrophic health spending on maternal care in public and private health centres in India: a comparative study of pre and post national health mission period.

    PubMed

    Mohanty, Sanjay K; Kastor, Anshul

    2017-09-18

    The National Health Mission (NHM), one of the largest publicly funded maternal health programs worldwide was initiated in 2005 to reduce maternal, neo-natal and infant mortality and out-of-pocket expenditure (OOPE) on maternal care in India. Though evidence suggests improvement in maternal and child health, little is known on the change in OOPE and catastrophic health spending (CHS) since the launch of NHM. The aim of this paper is to provide a comprehensive estimate of OOPE and CHS on maternal care by public and private health providers in pre and post NHM periods. The unit data from the 60th and 71st rounds of National Sample Survey (NSS) is used in the analyses. Descriptive statistics is used to understand the differentials in OOPE and CHS. The CHS is estimated based on capacity to pay, derived from household consumption expenditure, the subsistence expenditure (based on state specific poverty line) and household OOPE on maternal care. Data of both rounds are pooled to understand the impact of NHM on OOPE and CHS. The log-linear regression model and the logit regression models adjusted for state fixed effect, clustering and socio-economic and demographic correlates are used in the analyses. Women availing themselves of ante natal, natal and post natal care (all three maternal care services) from public health centres have increased from 11% in 2004 to 31% by 2014 while that from private health centres had increased from 12% to 20% during the same period. The mean OOPE on all three maternal care services from public health centres was US$60 in pre-NHM and US$86 in post-NHM periods while that from private health center was US$170 and US$300 during the same period. Controlling for socioeconomic and demographic correlates, the OOPE on delivery care from public health center had not shown any significant increase in post NHM period. The OOPE on delivery care in private health center had increased by 5.6 times compared to that from public health centers in pre NHM

  17. JAERI R & D on accelerator-based transmutation under OMEGA program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takizuka, T.; Nishida, T.; Mizumoto, M.

    1995-10-01

    The overview of the Japanese long-term research and development program on nuclide partitioning and transmutation, called {open_quotes}OMEGA,{close_quotes} is presented. Under this national program, major R&D activities are being carried out at JAERI, PNC, and CRIEPI. Accelerator-based transmutation study at JAERI is focused on a dedicated transmutor with a subcritical actinide-fueled subcritical core coupled with a spallation target driven by a high intensity proton accelerator. Two types of system concept, solid system and molten-salt system, are discussed. The solid system consists of sodium-cooled tungsten target and metallic actinide fuel. The molten-salt system is fueled with molten actinide chloride that acts alsomore » as a target material. The proposed plant transmutes about 250 kg of minor actinide per year, and generates enough electricity to power its own accelerator. JAERI is proposing the development of an intense proton linear accelerator ETA with 1.5 GeV-10 mA beam for engineering tests of accelerator-based transmutation. Recent achievements in the accelerator development are described.« less

  18. Roadmap for creating an accelerated three-year medical education program.

    PubMed

    Leong, Shou Ling; Cangiarella, Joan; Fancher, Tonya; Dodson, Lisa; Grochowski, Colleen; Harnik, Vicky; Hustedde, Carol; Jones, Betsy; Kelly, Christina; Macerollo, Allison; Reboli, Annette C; Rosenfeld, Melvin; Rundell, Kristen; Thompson, Tina; Whyte, Robert; Pusic, Martin

    2017-01-01

    Medical education is undergoing significant transformation. Many medical schools are moving away from the concept of seat time to competency-based education and introducing flexibility in the curriculum that allows individualization. In response to rising student debt and the anticipated physician shortage, 35% of US medical schools are considering the development of accelerated pathways. The roadmap described in this paper is grounded in the experiences of the Consortium of Accelerated Medical Pathway Programs (CAMPP) members in the development, implementation, and evaluation of one type of accelerated pathway: the three-year MD program. Strategies include developing a mission that guides curricular development - meeting regulatory requirements, attaining institutional buy-in and resources necessary to support the programs, including student assessment and mentoring - and program evaluation. Accelerated programs offer opportunities to innovate and integrate a mission benefitting students and the public. CAMPP: Consortium of accelerated medical pathway programs; GME: Graduate medical education; LCME: Liaison committee on medical education; NRMP: National residency matching program; UME: Undergraduate medical education.

  19. Transforming Readers: Teachers and Children in the Centre for Literacy in Primary Education Power of Reading Project

    ERIC Educational Resources Information Center

    O'Sullivan, Olivia; McGonigle, Sue

    2010-01-01

    This paper presents findings from a national project in England, The Power of Reading (Centre for Literacy in Primary Education), which has involved to date 41 projects over 5 years, in 16 Local Authorities nationally, with 900 schools and 1,350 teachers. The paper presents findings for the first 4 years. Our data demonstrate how professional…

  20. Strengthening health disaster risk management in Africa: multi-sectoral and people-centred approaches are required in the post-Hyogo Framework of Action era.

    PubMed

    Olu, Olushayo; Usman, Abdulmumini; Manga, Lucien; Anyangwe, Stella; Kalambay, Kalula; Nsenga, Ngoy; Woldetsadik, Solomon; Hampton, Craig; Nguessan, Francois; Benson, Angela

    2016-08-02

    In November 2012, the 62nd session of the Regional Committee for Africa adopted a comprehensive 10-year regional strategy for health disaster risk management (DRM). This was intended to operationalize the World Health Organization's core commitments to health DRM and the Hyogo Framework for Action 2005-2015 in the health sectors of the 47 African member states. This study reported the formative evaluation of the strategy, including evaluation of the progress in achieving nine targets (expected to be achieved incrementally by 2014, 2017, and 2022). We proposed recommendations for accelerating the strategy's implementation within the Sendai Framework for Disaster Risk Reduction. This study used a mixed methods design. A cross-sectional quantitative survey was conducted along with a review of available reports and information on the implementation of the strategy. A review meeting to discuss and finalize the study findings was also conducted. In total, 58 % of the countries assessed had established DRM coordination units within their Ministry of Health (MOH). Most had dedicated MOH DRM staff (88 %) and national-level DRM committees (71 %). Only 14 (58 %) of the countries had health DRM subcommittees using a multi-sectoral disaster risk reduction platform. Less than 40 % had conducted surveys such as disaster risk analysis, hospital safety index, and mapping of health resources availability. Key challenges in implementing the strategy were inadequate political will and commitment resulting in poor funding for health DRM, weak health systems, and a dearth of scientific evidence on mainstreaming DRM and disaster risk reduction in longer-term health system development programs. Implementation of the strategy was behind anticipated targets despite some positive outcomes, such as an increase in the number of countries with health DRM incorporated in their national health legislation, MOH DRM units, and functional health sub-committees within national DRM committees

  1. Operational flood forecasting system of Umbria Region "Functional Centre

    NASA Astrophysics Data System (ADS)

    Berni, N.; Pandolfo, C.; Stelluti, M.; Ponziani, F.; Viterbo, A.

    2009-04-01

    The hydrometeorological alert office (called "Decentrate Functional Centre" - CFD) of Umbria Region, in central Italy, is the office that provides technical tools able to support decisions when significant flood/landslide events occur, furnishing 24h support for the whole duration of the emergency period, according to the national directive DPCM 27 February 2004 concerning the "Operating concepts for functional management of national and regional alert system during flooding and landslide events for civil protection activities purposes" that designs, within the Italian Civil Defence Emergency Management System, a network of 21 regional Functional Centres coordinated by a central office at the National Civil Protection Department in Rome. Due to its "linking" role between Civil Protection "real time" activities and environmental/planning "deferred time" ones, the Centre is in charge to acquire and collect both real time and quasi-static data: quantitative data from monitoring networks (hydrometeorological stations, meteo radar, ...), meteorological forecasting models output, Earth Observation data, hydraulic and hydrological simulation models, cartographic and thematic GIS data (vectorial and raster type), planning studies related to flooding areas mapping, dam managing plans during flood events, non instrumental information from direct control of "territorial presidium". A detailed procedure for the management of critical events was planned, also in order to define the different role of various authorities and institutions involved. Tiber River catchment, of which Umbria region represents the main upper-medium portion, includes also regional trans-boundary issues very important to cope with, especially for what concerns large dam behavior and management during heavy rainfall. The alert system is referred to 6 different warning areas in which the territory has been divided into and based on a threshold system of three different increasing critical levels according

  2. Sheath field dynamics from time-dependent acceleration of laser-generated positrons

    NASA Astrophysics Data System (ADS)

    Kerr, Shaun; Fedosejevs, Robert; Link, Anthony; Williams, Jackson; Park, Jaebum; Chen, Hui

    2017-10-01

    Positrons produced in ultraintense laser-matter interactions are accelerated by the sheath fields established by fast electrons, typically resulting in quasi-monoenergetic beams. Experimental results from OMEGA EP show higher order features developing in the positron spectra when the laser energy exceeds one kilojoule. 2D PIC simulations using the LSP code were performed to give insight into these spectral features. They suggest that for high laser energies multiple, distinct phases of acceleration can occur due to time-dependent sheath field acceleration. The detailed dynamics of positron acceleration will be discussed. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344, and funded by LDRD 17-ERD-010.

  3. Electron Beam Focusing in the Linear Accelerator (linac)

    NASA Astrophysics Data System (ADS)

    Jauregui, Luis

    2015-10-01

    To produce consistent data with an electron accelerator, it is critical to have a well-focused beam. To keep the beam focused, quadrupoles (quads) are employed. Quads are magnets, which focus the beam in one direction (x or y) and defocus in the other. When two or more quads are used in series, a net focusing effect is achieved in both vertical and horizontal directions. At start up there is a 5% calibration error in the linac at Thomas Jefferson National Accelerator Facility. This means that the momentum of particles passing through the quads isn't always what is expected, which affects the focusing of the beam. The objective is to find exactly how sensitive the focusing in the linac is to this 5% error. A linac was simulated, which contained 290 RF Cavities with random electric fields (to simulate the 5% calibration error), and a total momentum kick of 1090 MeV. National Science Foundation, Department of Energy, Jefferson Lab, Old Dominion University.

  4. Controllable robust laser driven ion acceleration from near-critical density relativistic self-transparent plasma

    NASA Astrophysics Data System (ADS)

    Liu, Bin; Meyer-Ter-Vehn, Juergen; Ruhl, Hartmut

    2017-10-01

    We introduce an alternative approach for laser driven self-injected high quality ion acceleration. We call it ion wave breaking acceleration. It operates in relativistic self-transparent plasma for ultra-intense ultra-short laser pulses. Laser propagating in a transparent plasma excites an electron wave as well as an ion wave. When the ion wave breaks, a fraction of ions is self-injected into the positive part of the laser driven wake. This leads to a superior ion pulse with peaked energy spectra; in particular in realistic three-dimensional geometry, the injection occurs localized close to the laser axis producing highly directed bunches. A theory is developed to investigate the ion wave breaking dynamics. Three dimensional Particle-in-Cell simulations with pure-gaussian laser pulses and pre-expanded near-critical density plasma targets have been done to verify the theoretical results. It is shown that hundreds of MeV, easily controllable and manipulable, micron-scale size, highly collimated and quasi-mono-energetic ion beams can be produced by using ultra-intense ultra-short laser pulses with total laser energies less than 10 Joules. Such ion beams may find important applications in tumour therapy. B. Liu acknowledges support from the Alexander von Humboldt Foundation. B. Liu and H. Ruhl acknowledge supports from the Gauss Centre for Supercomputing (GCS), and the Cluster-of-Excellence Munich Centre for Advanced Photonics (MAP).

  5. Acceleration induced water removal from ear canals.

    NASA Astrophysics Data System (ADS)

    Kang, Hosung; Averett, Katelee; Jung, Sunghwan

    2017-11-01

    Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.

  6. Addiction research centres and the nurturing of creativity. The Chinese National Institute on Drug Dependence, Peking University: past, present and future.

    PubMed

    Wang, Xi; Zhao, Dong; Shi, Jie; Zhao, Chengzheng; Liu, Zhimin; Lu, Lin

    2010-09-01

    In the 25 years since drug abuse re-emerged in China in the 1980s, the National Institute of Drug Dependence (NIDD) has made many contributions to China's antidrug campaign. This present paper offers an account of the history, current status and future of drug dependence research at NIDD. NIDD was originally a research centre at Beijing Medical University, founded by the Chinese Ministry of Health to address the rapid spread of drug abuse in China. Originally, the main task of NIDD was to complete the commissions assigned by the government and university. Further developments transformed NIDD into a national research institute in the field of drug addiction that began to conduct its own research. NIDD has now created a professional team spread across several independent departments involved in neurobiological mechanisms, epidemiological surveys and monitoring, pre-clinical and clinical evaluation of new drugs (mainly analgesic drugs and detoxification drugs) and informatics and data analysis. As a university-based research institute, NIDD's funding derives mainly from grants provided by the government and financial support from international organizations. Its past and present research has a gained NIDD a reputation with both practitioners and policy makers in the field of drug addiction. In the future, NIDD will continue to engage in various aspects of drug addiction research and will enter the field of brain function.

  7. First muon acceleration using a radio-frequency accelerator

    NASA Astrophysics Data System (ADS)

    Bae, S.; Choi, H.; Choi, S.; Fukao, Y.; Futatsukawa, K.; Hasegawa, K.; Iijima, T.; Iinuma, H.; Ishida, K.; Kawamura, N.; Kim, B.; Kitamura, R.; Ko, H. S.; Kondo, Y.; Li, S.; Mibe, T.; Miyake, Y.; Morishita, T.; Nakazawa, Y.; Otani, M.; Razuvaev, G. P.; Saito, N.; Shimomura, K.; Sue, Y.; Won, E.; Yamazaki, T.

    2018-05-01

    Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu- ), which are bound states of positive muons (μ+) and two electrons, are generated from μ+'s through the electron capture process in an aluminum degrader. The generated Mu- 's are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ). In the RFQ, the Mu- 's are accelerated to 89 keV. The accelerated Mu- 's are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

  8. Research and Development Digest--5. A Summary of Published Research by the Centre for the Period 1 July, 1989--30 June, 1990.

    ERIC Educational Resources Information Center

    Hall, William C., Ed.

    This publication summarizes 50 research studies published by the TAFE (Technical and Further Education) National Centre for Research and Development Ltd., Australia. The document is presented in 10 sections. The first section provides an overview of the Centre's work and its publications, describing how best to use them. Sections 2-6 consist of…

  9. An introduction to family-centred services for children affected by HIV and AIDS.

    PubMed

    Richter, Linda

    2010-06-23

    Family-centred services in the context of HIV/AIDS acknowledge a broad view of a "family system" and ideally include comprehensive treatment and care, community agencies and coordinated case management. The importance of family-centred care for children affected by HIV/AIDS has been recognized for some time. There is a clear confluence of changing social realities and the needs of children in families affected by HIV and AIDS, but a change of paradigm in rendering services to children through families, in both high-prevalence and concentrated epidemic settings, has been slow to emerge.Despite a wide variety of model approaches, interventions, whether medical or psychosocial, still tend to target individuals rather than families. It has become clear that an individualistic approach to children affected by HIV and AIDS leads to confusion and misdirection of the global, national and local response. The almost exclusive focus on orphans, defined initially as a child who had lost one or both parents to AIDS, has occluded appreciation of the broader impact on children exposed to risk in other ways and the impact of the epidemic on families, communities and services for children. In addition, it led to narrowly focused, small-scale social welfare and case management approaches with little impact on government action, global and national policy, integration with health and education interventions, and increased funding.National social protection programmes that strengthen families are now established in several countries hard hit by AIDS, and large-scale pilots are underway in others. These efforts are supported by international and national development agencies, increasingly by governments and, more recently, by UNAIDS and the global AIDS community.There is no doubt that this is the beginning of a road and that there is still a long way to go, including basic research on families, family interventions, and effectiveness and costs of family-centred approaches. It is also

  10. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    NASA Astrophysics Data System (ADS)

    Chen, Teng; Elias, Luis R.

    1995-02-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations.

  11. PARTICLE ACCELERATOR

    DOEpatents

    Teng, L.C.

    1960-01-19

    ABS>A combination of two accelerators, a cyclotron and a ring-shaped accelerator which has a portion disposed tangentially to the cyclotron, is described. Means are provided to transfer particles from the cyclotron to the ring accelerator including a magnetic deflector within the cyclotron, a magnetic shield between the ring accelerator and the cyclotron, and a magnetic inflector within the ring accelerator.

  12. Advanced low-beta cavity development for proton and ion accelerators

    NASA Astrophysics Data System (ADS)

    Conway, Z. A.; Kelly, M. P.; Ostroumov, P. N.

    2015-05-01

    Recent developments in designing and processing low-beta superconducting cavities at Argonne National Laboratory are very encouraging for future applications requiring compact proton and ion accelerators. One of the major benefits of these accelerating structures is achieving real-estate accelerating gradients greater than 3 MV/m very efficiently either continuously or for long-duty cycle operation (>1%). The technology has been implemented in low-beta accelerator cryomodules for the Argonne ATLAS heavy-ion linac where the cryomodules are required to have real-estate gradients of more than 3 MV/m. In offline testing low-beta cavities with even higher gradients have already been achieved. This paper will review this work where we have achieved surface fields greater than 166 mT magnetic and 117 MV/m electric in a 72 MHz quarter-wave resonator optimized for β = 0.077 ions.

  13. Earthquake and failure forecasting in real-time: A Forecasting Model Testing Centre

    NASA Astrophysics Data System (ADS)

    Filgueira, Rosa; Atkinson, Malcolm; Bell, Andrew; Main, Ian; Boon, Steven; Meredith, Philip

    2013-04-01

    Across Europe there are a large number of rock deformation laboratories, each of which runs many experiments. Similarly there are a large number of theoretical rock physicists who develop constitutive and computational models both for rock deformation and changes in geophysical properties. Here we consider how to open up opportunities for sharing experimental data in a way that is integrated with multiple hypothesis testing. We present a prototype for a new forecasting model testing centre based on e-infrastructures for capturing and sharing data and models to accelerate the Rock Physicist (RP) research. This proposal is triggered by our work on data assimilation in the NERC EFFORT (Earthquake and Failure Forecasting in Real Time) project, using data provided by the NERC CREEP 2 experimental project as a test case. EFFORT is a multi-disciplinary collaboration between Geoscientists, Rock Physicists and Computer Scientist. Brittle failure of the crust is likely to play a key role in controlling the timing of a range of geophysical hazards, such as volcanic eruptions, yet the predictability of brittle failure is unknown. Our aim is to provide a facility for developing and testing models to forecast brittle failure in experimental and natural data. Model testing is performed in real-time, verifiably prospective mode, in order to avoid selection biases that are possible in retrospective analyses. The project will ultimately quantify the predictability of brittle failure, and how this predictability scales from simple, controlled laboratory conditions to the complex, uncontrolled real world. Experimental data are collected from controlled laboratory experiments which includes data from the UCL Laboratory and from Creep2 project which will undertake experiments in a deep-sea laboratory. We illustrate the properties of the prototype testing centre by streaming and analysing realistically noisy synthetic data, as an aid to generating and improving testing methodologies in

  14. Perceptual centres in speech - an acoustic analysis

    NASA Astrophysics Data System (ADS)

    Scott, Sophie Kerttu

    Perceptual centres, or P-centres, represent the perceptual moments of occurrence of acoustic signals - the 'beat' of a sound. P-centres underlie the perception and production of rhythm in perceptually regular speech sequences. P-centres have been modelled both in speech and non speech (music) domains. The three aims of this thesis were toatest out current P-centre models to determine which best accounted for the experimental data bto identify a candidate parameter to map P-centres onto (a local approach) as opposed to the previous global models which rely upon the whole signal to determine the P-centre the final aim was to develop a model of P-centre location which could be applied to speech and non speech signals. The first aim was investigated by a series of experiments in which a) speech from different speakers was investigated to determine whether different models could account for variation between speakers b) whether rendering the amplitude time plot of a speech signal affects the P-centre of the signal c) whether increasing the amplitude at the offset of a speech signal alters P-centres in the production and perception of speech. The second aim was carried out by a) manipulating the rise time of different speech signals to determine whether the P-centre was affected, and whether the type of speech sound ramped affected the P-centre shift b) manipulating the rise time and decay time of a synthetic vowel to determine whether the onset alteration was had more affect on P-centre than the offset manipulation c) and whether the duration of a vowel affected the P-centre, if other attributes (amplitude, spectral contents) were held constant. The third aim - modelling P-centres - was based on these results. The Frequency dependent Amplitude Increase Model of P-centre location (FAIM) was developed using a modelling protocol, the APU GammaTone Filterbank and the speech from different speakers. The P-centres of the stimuli corpus were highly predicted by attributes of

  15. Establishment of a National Accelerator Facility: Design and construction phase

    NASA Astrophysics Data System (ADS)

    1981-06-01

    The main components of an accelerator facility for nuclear physics, isotope production, and radiotherapy in South Africa are in 8-MeV solid pole injector cyclotron and a separated sector cyclotron with a k-value of 200 MeV. Progress made in the development of the light ion injector and in the design of the control and beam transport systems is described. Mechanical and engineering tasks associated with component manufacture are discussed as well as the construction of the building to house the facility and the installation of necessary services.

  16. Acceleration Modes and Transitions in Pulsed Plasma Accelerators

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Greve, Christine M.

    2018-01-01

    Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma

  17. Abrupt acceleration of a 'cold' ultrarelativistic wind from the Crab pulsar.

    PubMed

    Aharonian, F A; Bogovalov, S V; Khangulyan, D

    2012-02-15

    Pulsars are thought to eject electron-positron winds that energize the surrounding environment, with the formation of a pulsar wind nebula. The pulsar wind originates close to the light cylinder, the surface at which the pulsar co-rotation velocity equals the speed of light, and carries away much of the rotational energy lost by the pulsar. Initially the wind is dominated by electromagnetic energy (Poynting flux) but later this is converted to the kinetic energy of bulk motion. It is unclear exactly where this takes place and to what speed the wind is accelerated. Although some preferred models imply a gradual acceleration over the entire distance from the magnetosphere to the point at which the wind terminates, a rapid acceleration close to the light cylinder cannot be excluded. Here we report that the recent observations of pulsed, very high-energy γ-ray emission from the Crab pulsar are explained by the presence of a cold (in the sense of the low energy of the electrons in the frame of the moving plasma) ultrarelativistic wind dominated by kinetic energy. The conversion of the Poynting flux to kinetic energy should take place abruptly in the narrow cylindrical zone of radius between 20 and 50 light-cylinder radii centred on the axis of rotation of the pulsar, and should accelerate the wind to a Lorentz factor of (0.5-1.0) × 10(6). Although the ultrarelativistic nature of the wind does support the general model of pulsars, the requirement of the very high acceleration of the wind in a narrow zone not far from the light cylinder challenges current models.

  18. CCS-MIP: Low cost Customizable Control Centre

    NASA Technical Reports Server (NTRS)

    Labezin, Christian; Vielcanet, Pierre

    1994-01-01

    The positioning and station keeping of French national satellites are among the main missions of CNES French Space Agency CNES. The related experience and skills of the Toulouse Space Centre are reknown and often required at international level for a wide range of missions. CISI, a software engineering company, has been contributing during the last 20 years to the development of the French space programs, particularly in the field of space missions ground control segments. The CCS-MIP system, presented here, is a satellite positioning and station-keeping system designed to answer the CNES multi-mission needs, easily adaptable for a wide range of applications.

  19. A French network of bipolar expert centres: a model to close the gap between evidence-based medicine and routine practice.

    PubMed

    Henry, Chantal; Etain, Bruno; Mathieu, Flavie; Raust, Aurélie; Vibert, Jean-Francois; Scott, Jan; Leboyer, Marion

    2011-06-01

    Bipolar disorders are a major public health concern. Efforts to provide optimal care by general practitioners and psychiatrists are undermined by the complexity of the disorder and difficulties in applying clinical practice guidelines and new research findings to the spectrum of cases seen in day to day practice. A national network of bipolar expert centres was established. Each centre has established strong links to local health services and provides support to clinicians in delivering personalized care plans derived from systematic case assessments undertaken at the centre. A common set of diagnostic and clinical assessment tools has been adopted at eight centres. Evaluations are undertaken by trained assessors and cross-centre reliability is monitored. A web application, e-bipolar© is used to record data in a common computerized medical file. Anonymized data is entered into a shared national database for use in multi-centre audit and research. Instead of offering treatment advice based on clinical practice guidelines recommendations for selected sub-populations of patients (a 'top-down' approach), the French bipolar network offers systematic, comprehensive, longitudinal, and multi-dimensional assessments of cases representative of general bipolar populations. This 'bottom-up' strategy may offer a more efficient and effective way to transfer knowledge and share expertise as the referrer can appreciate the rationale underpinning suggested treatment protocols and more readily apply such principles and approaches to other cases. The network also builds an infrastructure for clinical cohort and comparative-effectiveness research on more representative patient populations. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Real time monitoring of risk-adjusted paediatric cardiac surgery outcomes using variable life-adjusted display: implementation in three UK centres

    PubMed Central

    Pagel, Christina; Utley, Martin; Crowe, Sonya; Witter, Thomas; Anderson, David; Samson, Ray; McLean, Andrew; Banks, Victoria; Tsang, Victor; Brown, Katherine

    2013-01-01

    Objective To implement routine in-house monitoring of risk-adjusted 30-day mortality following paediatric cardiac surgery. Design Collaborative monitoring software development and implementation in three specialist centres. Patients and methods Analyses incorporated 2 years of data routinely audited by the National Institute of Cardiac Outcomes Research (NICOR). Exclusion criteria were patients over 16 or undergoing non-cardiac or only catheter procedures. We applied the partial risk adjustment in surgery (PRAiS) risk model for death within 30 days following surgery and generated variable life-adjusted display (VLAD) charts for each centre. These were shared with each clinical team and feedback was sought. Results Participating centres were Great Ormond Street Hospital, Evelina Children's Hospital and The Royal Hospital for Sick Children in Glasgow. Data captured all procedures performed between 1 January 2010 and 31 December 2011. This incorporated 2490 30-day episodes of care, 66 of which were associated with a death within 30 days.The VLAD charts generated for each centre displayed trends in outcomes benchmarked to recent national outcomes. All centres ended the 2-year period within four deaths from what would be expected. The VLAD charts were shared in multidisciplinary meetings and clinical teams reported that they were a useful addition to existing quality assurance initiatives. Each centre is continuing to use the prototype software to monitor their in-house surgical outcomes. Conclusions Timely and routine monitoring of risk-adjusted mortality following paediatric cardiac surgery is feasible. Close liaison with hospital data managers as well as clinicians was crucial to the success of the project. PMID:23564473

  1. RTEMS CENTRE- Support and Maintenance CENTRE to RTEMS Operating System

    NASA Astrophysics Data System (ADS)

    Silva, H.; Constantino, A.; Coutunho, M.; Freitas, D.; Faustino, S.; Mota, M.; Colaço, P.; Zulianello, M.

    2008-08-01

    RTEMS stands for Real-Time Operating System for Multiprocessor Systems. It is a full featured Real Time Operating System that supports a variety of open APIs and interface standards. It provides a high performance environment for embedded applications, including a fixed-priority preemptive/non-preemptive scheduler, a comprehensive set of multitasking operations and a large range of supported architectures. Support and maintenance CENTRE to RTEMS operating system (RTEMS CENTRE) is a joint initiative of ESA-Portugal Task force, aiming to build a strong technical competence in the space flight (on- board) software, to offer support, maintenance and improvements to RTEMS. This paper provides a high level description of the current and future activities of the RTEMS CENTRE. It presents a brief description of the RTEMS operating system, a description of the tools developed and distributed to the community [1] and the improvements to be made to the operating system, including facilitation for the qualification of RTEMS (4.8.0) [2] for the space missions.

  2. Politics, policy and payment--facilitators or barriers to person-centred rehabilitation?

    PubMed

    Turner-Stokes, Lynne

    This paper explores the tensions between politics and payment in providing affordable services that satisfy the public demand for patient-centred care. The two main approaches taken by the UK Government to curtail the spiralling costs of healthcare have been to focus development in priority areas and to cap spending through the introduction of a fixed-tariff episode-based funding system. The National Service Framework for Long Term Neurological Conditions embraces many laudable principles of person-centred management, but the 'one-size-fits all' approach to reimbursement potentially cuts right across these. A series of tools have been developed to determine complexity of rehabilitation needs that will support the development of banded tariffs. A practical approach is also offered to demonstrate the cost-efficiency of rehabilitation services for people with complex needs, and help to ensure that they are not excluded from treatment because of their higher treatment costs. Whilst responding to public demand for person-centred care, we must recognize the current financial pressure on healthcare systems. Clinicians will have greater credibility if they routinely collect and share outcomes that demonstrate the economic benefits of intervention, as well the impact on health, function and quality of life.

  3. Theoretical and Experimental Studies in Accelerator Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenzweig, James

    This report describes research supported by the US Dept. of Energy Office of High Energy Physics (OHEP), performed by the UCLA Particle Beam Physics Laboratory (PBPL). The UCLA PBPL has, over the last two decades-plus, played a critical role in the development of advanced accelerators, fundamental beam physics, and new applications enabled by these thrusts, such as new types of accelerator-based light sources. As the PBPL mission is broad it is natural that it has been grown within the context of the accelerator science and technology stewardship of the OHEP. Indeed, steady OHEP support for the program has always beenmore » central to the success of the PBPL; it has provided stability, and above all has set the over-arching themes for our research directions, which have producing over 500 publications (>120 in high level journals). While other agency support has grown notably in recent years, permitting more vigorous pursuit of the program, it is transient by comparison. Beyond permitting program growth in a time of flat OHEP budgets, the influence of other agency missions is found in push to adapt advanced accelerator methods to applications, in light of the success the field has had in proof-of-principle experiments supported first by the DoE OHEP. This three-pronged PBPL program — advanced accelerators, fundamental beam physics and technology, and revolutionary applications — has produced a generation of students that have had a profound affect on the US accelerator physics community. PBPL graduates, numbering 28 in total, form a significant population group in the accelerator community, playing key roles as university faculty, scientific leaders in national labs (two have been named Panofsky Fellows at SLAC), and vigorous proponents of industrial application of accelerators. Indeed, the development of advanced RF, optical and magnet technology at the PBPL has led directly to the spin-off company, RadiaBeam Technologies, now a leading industrial

  4. The application of Firefly algorithm in an Adaptive Emergency Evacuation Centre Management (AEECM) for dynamic relocation of flood victims

    NASA Astrophysics Data System (ADS)

    ChePa, Noraziah; Hashim, Nor Laily; Yusof, Yuhanis; Hussain, Azham

    2016-08-01

    Flood evacuation centre is defined as a temporary location or area of people from disaster particularly flood as a rescue or precautionary measure. Gazetted evacuation centres are normally located at secure places which have small chances from being drowned by flood. However, due to extreme flood several evacuation centres in Kelantan were unexpectedly drowned. Currently, there is no study done on proposing a decision support aid to reallocate victims and resources of the evacuation centre when the situation getting worsens. Therefore, this study proposes a decision aid model to be utilized in realizing an adaptive emergency evacuation centre management system. This study undergoes two main phases; development of algorithm and models, and development of a web-based and mobile app. The proposed model operates using Firefly multi-objective optimization algorithm that creates an optimal schedule for the relocation of victims and resources for an evacuation centre. The proposed decision aid model and the adaptive system can be applied in supporting the National Security Council's respond mechanisms for handling disaster management level II (State level) especially in providing better management of the flood evacuating centres.

  5. Electrical Engineering in Los Alamos Neutron Science Center Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, Michael James

    The field of electrical engineering plays a significant role in particle accelerator design and operations. Los Alamos National Laboratories LANSCE facility utilizes the electrical energy concepts of power distribution, plasma generation, radio frequency energy, electrostatic acceleration, signals and diagnostics. The culmination of these fields produces a machine of incredible potential with uses such as isotope production, neutron spallation, neutron imaging and particle analysis. The key isotope produced in LANSCE isotope production facility is Strontium-82 which is utilized for medical uses such as cancer treatment and positron emission tomography also known as PET scans. Neutron spallation is one of the verymore » few methods used to produce neutrons for scientific research the other methods are natural decay of transuranic elements from nuclear reactors. Accelerator produce neutrons by accelerating charged particles into neutron dense elements such as tungsten imparting a neutral particle with kinetic energy, this has the benefit of producing a large number of neutrons as well as minimizing the waste generated. Utilizing the accelerator scientist can gain an understanding of how various particles behave and interact with matter to better understand the natural laws of physics and the universe around us.« less

  6. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adolphsen, Chris

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  7. Roles of Regional Centres of Expertise on Education for Sustainable Development: Lessons Learnt in the First Half of the UNDESD

    ERIC Educational Resources Information Center

    Fadeeva, Zinaida; Mochizuki, Yoko

    2010-01-01

    As its major contribution to the United Nations Decade of Education for Sustainable Development (UN DESD, 2005-2014), the United Nations University (UNU) has promoted the establishment of Regional Centres of Expertise on education for sustainable development (RCEs) and their net-working to build innovative multistakeholder platforms for ESD…

  8. Advanced low-beta cavity development for proton and ion accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conway, Z. A.; Kelly, M. P.; Ostroumov, P. N.

    2015-05-01

    Recent developments in designing and processing low-beta superconducting cavities at Argonne National Laboratory are very encouraging for future applications requiring compact proton and ion accelerators. One of the major benefits of these accelerating structures is achieving real-estate accelerating gradients greater than 3 MV/m very efficiently either continuously or for long-duty cycle operation (>1%). The technology has been implemented in low-beta accelerator cryomodules for the Argonne ATLAS heavy-ion linac where the cryomodules are required to have real-estate gradients of more than 3 MV/m. In offline testing low-beta cavities with even higher gradients have already been achieved. This paper will review thismore » work where we have achieved surface fields greater than 166 mT magnetic and 117 MV/m electric in a 72 MHz quarter-wave resonator optimized for beta = 0.077 ions.« less

  9. A Canadian model for building university and community partnerships: centre for research & education on violence against women and children.

    PubMed

    Jaffe, Peter G; Berman, Helene; MacQuarrie, Barb

    2011-09-01

    The importance of Canadian research on violence against women became a national focus after the 1989 murder of 14 women at École Polytechnique in Montreal. This tragedy led to several federal government studies that identified a need to develop centers for applied research and community-university alliances on violence against women. One such center is the Centre for Research & Education on Violence against Women and Children. The Centre was founded in London, Canada in 1992 out of a partnership of a university, a community college, and community services. The centre's history and current activities are summarized as a model for the development and sustainability of similar centers.

  10. The politics of patient-centred care.

    PubMed

    Kreindler, Sara A

    2015-10-01

    Despite widespread belief in the importance of patient-centred care, it remains difficult to create a system in which all groups work together for the good of the patient. Part of the problem may be that the issue of patient-centred care itself can be used to prosecute intergroup conflict. This qualitative study of texts examined the presence and nature of intergroup language within the discourse on patient-centred care. A systematic SCOPUS and Google search identified 85 peer-reviewed and grey literature reports that engaged with the concept of patient-centred care. Discourse analysis, informed by the social identity approach, examined how writers defined and portrayed various groups. Managers, physicians and nurses all used the discourse of patient-centred care to imply that their own group was patient centred while other group(s) were not. Patient organizations tended to downplay or even deny the role of managers and providers in promoting patient centredness, and some used the concept to advocate for controversial health policies. Intergroup themes were even more obvious in the rhetoric of political groups across the ideological spectrum. In contrast to accounts that juxtaposed in-groups and out-groups, those from reportedly patient-centred organizations defined a 'mosaic' in-group that encompassed managers, providers and patients. The seemingly benign concept of patient-centred care can easily become a weapon on an intergroup battlefield. Understanding this dimension may help organizations resolve the intergroup tensions that prevent collective achievement of a patient-centred system. © 2013 John Wiley & Sons Ltd.

  11. Roadmap for creating an accelerated three-year medical education program

    PubMed Central

    Leong, Shou Ling; Cangiarella, Joan; Fancher, Tonya; Dodson, Lisa; Grochowski, Colleen; Harnik, Vicky; Hustedde, Carol; Jones, Betsy; Kelly, Christina; Macerollo, Allison; Reboli, Annette C.; Rosenfeld, Melvin; Rundell, Kristen; Thompson, Tina; Whyte, Robert; Pusic, Martin

    2017-01-01

    ABSTRACT Medical education is undergoing significant transformation. Many medical schools are moving away from the concept of seat time to competency-based education and introducing flexibility in the curriculum that allows individualization. In response to rising student debt and the anticipated physician shortage, 35% of US medical schools are considering the development of accelerated pathways. The roadmap described in this paper is grounded in the experiences of the Consortium of Accelerated Medical Pathway Programs (CAMPP) members in the development, implementation, and evaluation of one type of accelerated pathway: the three-year MD program. Strategies include developing a mission that guides curricular development – meeting regulatory requirements, attaining institutional buy-in and resources necessary to support the programs, including student assessment and mentoring – and program evaluation. Accelerated programs offer opportunities to innovate and integrate a mission benefitting students and the public. Abbreviations: CAMPP: Consortium of accelerated medical pathway programs; GME: Graduate medical education; LCME: Liaison committee on medical education; NRMP: National residency matching program; UME: Undergraduate medical education PMID:29117817

  12. Developing person-centred practice in hip fracture care for older people.

    PubMed

    Christie, Jane; Macmillan, Maureen; Currie, Colin; Matthews-Smith, Gerardine

    2016-12-14

    To facilitate a multidisciplinary collaborative approach to developing person-centred practice in hip fracture care for older people. Collaborative inquiry, a form of action research, was used to collect data for this study. It involved exploration of dilemmas, questions and problems that are part of human experience. Clinical leaders from different disciplines (n=16), who work with older people with hip fractures at different stages of the care pathway, participated in a series of facilitated action meetings. The practice development techniques used in this study included: identifying the strengths and limitations of the current service, values clarification, creating a shared vision, sharing clinical stories, reviewing case records, and reflecting on the experiences of three older people and two caregivers. Hip fracture care was based on meeting service targets, national guidelines and audits. Care was fragmented across different service delivery units, with professional groups working independently. This resulted in suboptimal communication between members of the multidisciplinary group of clinical leaders and care that was process-driven rather than person-centred. Spending time away from clinical practice enabled the multidisciplinary group to collaborate to understand care from the patients' and caregivers' perspectives, and to reflect critically on the care experience as a whole. To develop a person-centred workplace culture, the multidisciplinary team requires facilitated time for reflection. Ongoing facilitative leadership would enable the multidisciplinary team to collaborate effectively to deliver safe, effective person-centred practice in hip fracture care for older people.

  13. Spherical tokamaks with plasma centre-post

    NASA Astrophysics Data System (ADS)

    Ribeiro, Celso

    2013-10-01

    The metal centre-post (MCP) in tokamaks is a structure which carries the total toroidal field current and also houses the Ohmic heating solenoid in conventional or low aspect ratio (Spherical)(ST) tokamaks. The MCP and solenoid are critical components for producing the toroidal field and for the limited Ohmic flux in STs. Constraints for a ST reactor related to these limitations lead to a minimum plasma aspect ratio of 1.4 which reduces the benefit of operation at higher betas in a more compact ST reactor. Replacing the MCP is of great interest for reactor-based ST studies since the device is simplified, compactness increased, and maintenance reduced. An experiment to show the feasibility of using a plasma centre-post (PCP) is being currently under construction and involves a high level of complexity. A preliminary study of a very simple PCP, which is ECR(Electron Cyclotron Resonance)-assisted and which includes an innovative fuelling system based on pellet injection, has recently been reported. This is highly suitable for an ultra-low aspect ratio tokamak (ULART) device. Advances on this PCP ECR-assisted concept within a ULART and the associated fuelling system are presented here, and will include the field topology for the PCP ECR-assisted scheme, pellet ablation modeling, and a possible global equilibrium simulation. VIE-ITCR, IAEA-CRP contr.17592, National Instruments-Costa Rica.

  14. Claims for fertility interventions: a systematic assessment of statements on UK fertility centre websites

    PubMed Central

    Spencer, E A; Mahtani, K R; Goldacre, B; Heneghan, C

    2016-01-01

    Objectives Fertility services in the UK are offered by over 200 Human Fertilisation and Embryology Authority (HFEA)-registered NHS and private clinics. While in vitro fertilisation (IVF) and intracytoplasmic sperm injection (ICSI) form part of the National Institute for Health and Care Excellence (NICE) guidance, many further interventions are offered. We aimed to record claims of benefit for interventions offered by fertility centres via information on the centres' websites and record what evidence was cited for these claims. Methods We obtained from HFEA a list of all UK centres providing fertility treatments and examined their websites. We listed fertility interventions offered in addition to standard IVF and ICSI and recorded statements about interventions that claimed or implied improvements in fertility in healthy women. We recorded which claims were quantified, and the evidence cited in support of the claims. Two reviewers extracted data from websites. We accessed websites from 21 December 2015 to 31 March 2016. Results We found 233 websites for HFEA-registered fertility treatment centres, of which 152 (65%) were excluded as duplicates or satellite centres, 2 were andrology clinics and 5 were unavailable or under construction websites. In total, 74 fertility centre websites, incorporating 1401 web pages, were examined for claims. We found 276 claims of benefit relating to 41 different fertility interventions made by 60 of the 74 centres (median 3 per website; range 0 to 10). Quantification was given for 79 (29%) of the claims. 16 published references were cited 21 times on 13 of the 74 websites. Conclusions Many fertility centres in the UK offer a range of treatments in addition to standard IVF procedures, and for many of these interventions claims of benefit are made. In most cases, the claims are not quantified and evidence is not cited to support the claims. There is a need for more information on interventions to be made available by fertility centres

  15. National VET Research Priorities: 2010 and beyond. Discussion Paper

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2009

    2009-01-01

    National Centre for Vocational Education Research (NCVER) is undertaking a consultation process to determine the next set of National Research Priorities which will guide research activities in the post-compulsory education and training arena, particularly in relation to vocational education and training. This discussion paper, and the…

  16. Definitive care in level 3 trauma centres after severe injury: A comparison of clinical characteristics and outcomes.

    PubMed

    Gomez, David; Alali, Aziz S; Xiong, Wei; Zarzaur, Ben L; Mann, N Clay; Nathens, Avery B

    2015-09-01

    The role of level 3 trauma centres (TC) in inclusive trauma systems has not been well defined. The absence of nationally recognised inter-facility transfer criteria for inclusive systems has often left individual level 3 TCs to decide upon their own what their spectrum of care is and particularly which severely injured patients to admit for definitive care. Retrospective cohort study in which the principal objective was to compare the characteristics and outcomes of severely injured (injury severity score>15) adult patients (≥18 years) who received definitive care at level 3 centres with severely injured adult patients who were transferred to level 1-2 TCs during the same time period. Data were derived from the National Trauma Data Bank (2010-2011). First, we utilised hierarchical logistic regression models to evaluate the risk-adjusted mortality of patients admitted at level 3 TCs compared to those who were transferred to level 1-2 TCs. Subgroup analysis was carried out for patients with isolated traumatic brain injury (iTBI). Finally, we explored the extent of variation in risk-adjusted mortality across level 3 TCs. We identified 6433 severely injured patients who received definitive care across 150 level 3 TCs and 41,165 severely injured patients transferred to level 1-2 centres. Patients who received definitive care at level 3 TCs had a lower comorbidity burden and different injury profiles compared to those transferred to level 1-2 centres. There was no difference in crude mortality (10% vs. 11%, standardised difference 0.04); however, after risk-adjustment, the odds of death for patients who received definitive care at level 3 TCs were 1.24-fold higher (95%CI 1.08-1.43) when compared to those transferred to level 1-2 centres. A trend towards a higher likelihood of death at level 3 centres was observed when analysis was limited to patients with iTBI. Risk-adjusted mortality across level 3 TCs was with few exceptions, homogeneous (<10% of level 3 TCs were

  17. Covariant Uniform Acceleration

    NASA Astrophysics Data System (ADS)

    Friedman, Yaakov; Scarr, Tzvi

    2013-04-01

    We derive a 4D covariant Relativistic Dynamics Equation. This equation canonically extends the 3D relativistic dynamics equation , where F is the 3D force and p = m0γv is the 3D relativistic momentum. The standard 4D equation is only partially covariant. To achieve full Lorentz covariance, we replace the four-force F by a rank 2 antisymmetric tensor acting on the four-velocity. By taking this tensor to be constant, we obtain a covariant definition of uniformly accelerated motion. This solves a problem of Einstein and Planck. We compute explicit solutions for uniformly accelerated motion. The solutions are divided into four Lorentz-invariant types: null, linear, rotational, and general. For null acceleration, the worldline is cubic in the time. Linear acceleration covariantly extends 1D hyperbolic motion, while rotational acceleration covariantly extends pure rotational motion. We use Generalized Fermi-Walker transport to construct a uniformly accelerated family of inertial frames which are instantaneously comoving to a uniformly accelerated observer. We explain the connection between our approach and that of Mashhoon. We show that our solutions of uniformly accelerated motion have constant acceleration in the comoving frame. Assuming the Weak Hypothesis of Locality, we obtain local spacetime transformations from a uniformly accelerated frame K' to an inertial frame K. The spacetime transformations between two uniformly accelerated frames with the same acceleration are Lorentz. We compute the metric at an arbitrary point of a uniformly accelerated frame. We obtain velocity and acceleration transformations from a uniformly accelerated system K' to an inertial frame K. We introduce the 4D velocity, an adaptation of Horwitz and Piron s notion of "off-shell." We derive the general formula for the time dilation between accelerated clocks. We obtain a formula for the angular velocity of a uniformly accelerated object. Every rest point of K' is uniformly accelerated, and

  18. Accelerator System Model (ASM) user manual with physics and engineering model documentation. ASM version 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1993-07-01

    The Accelerator System Model (ASM) is a computer program developed to model proton radiofrequency accelerators and to carry out system level trade studies. The ASM FORTRAN subroutines are incorporated into an intuitive graphical user interface which provides for the {open_quotes}construction{close_quotes} of the accelerator in a window on the computer screen. The interface is based on the Shell for Particle Accelerator Related Codes (SPARC) software technology written for the Macintosh operating system in the C programming language. This User Manual describes the operation and use of the ASM application within the SPARC interface. The Appendix provides a detailed description of themore » physics and engineering models used in ASM. ASM Version 1.0 is joint project of G. H. Gillespie Associates, Inc. and the Accelerator Technology (AT) Division of the Los Alamos National Laboratory. Neither the ASM Version 1.0 software nor this ASM Documentation may be reproduced without the expressed written consent of both the Los Alamos National Laboratory and G. H. Gillespie Associates, Inc.« less

  19. Analyzing radial acceleration with a smartphone acceleration sensor

    NASA Astrophysics Data System (ADS)

    Vogt, Patrik; Kuhn, Jochen

    2013-03-01

    This paper continues the sequence of experiments using the acceleration sensor of smartphones (for description of the function and the use of the acceleration sensor, see Ref. 1) within this column, in this case for analyzing the radial acceleration.

  20. Person-centred web-based support--development through a Swedish multi-case study.

    PubMed

    Josefsson, Ulrika; Berg, Marie; Koinberg, Ingalill; Hellström, Anna-Lena; Nolbris, Margaretha Jenholt; Ranerup, Agneta; Lundin, Carina Sparud; Skärsäter, Ingela

    2013-10-19

    Departing from the widespread use of the internet in modern society and the emerging use of web applications in healthcare this project captures persons' needs and expectations in order to develop highly usable web recourses. The purpose of this paper is to outline a multi-case research project focused on the development and evaluation of person-centred web-based support for people with long-term illness. To support the underlying idea to move beyond the illness, we approach the development of web support from the perspective of the emergent area of person-centred care. The project aims to contribute to the ongoing development of web-based supports in health care and to the emerging field of person-centred care. The research design uses a meta-analytical approach through its focus on synthesizing experiences from four Swedish regional and national cases of design and use of web-based support in long-term illness. The cases include children (bladder dysfunction and urogenital malformation), young adults (living close to persons with mental illness), and two different cases of adults (women with breast cancer and childbearing women with type 1 diabetes). All of the cases are ongoing, though in different stages of design, implementation, and analysis. This, we argue, will lead to a synthesis of results on a meta-level not yet described. To allow valid comparisons between the four cases we explore and problematize them in relation to four main aspects: 1) The use of people's experiences and needs; 2) The role of use of theories in the design of person-centred web-based supports; 3) The evaluation of the effects of health outcomes for the informants involved and 4) The development of a generic person-centred model for learning and social support for people with long-term illness and their significant others. Person-centred web-based support is a new area and few studies focus on how web-based interventions can contribute to the development of person-centred care. In

  1. Person-centred web-based support - development through a Swedish multi-case study

    PubMed Central

    2013-01-01

    Background Departing from the widespread use of the internet in modern society and the emerging use of web applications in healthcare this project captures persons’ needs and expectations in order to develop highly usable web recourses. The purpose of this paper is to outline a multi-case research project focused on the development and evaluation of person-centred web-based support for people with long-term illness. To support the underlying idea to move beyond the illness, we approach the development of web support from the perspective of the emergent area of person-centred care. The project aims to contribute to the ongoing development of web-based supports in health care and to the emerging field of person-centred care. Methods/Design The research design uses a meta-analytical approach through its focus on synthesizing experiences from four Swedish regional and national cases of design and use of web-based support in long-term illness. The cases include children (bladder dysfunction and urogenital malformation), young adults (living close to persons with mental illness), and two different cases of adults (women with breast cancer and childbearing women with type 1 diabetes). All of the cases are ongoing, though in different stages of design, implementation, and analysis. This, we argue, will lead to a synthesis of results on a meta-level not yet described. Discussion To allow valid comparisons between the four cases we explore and problematize them in relation to four main aspects: 1) The use of people’s experiences and needs; 2) The role of use of theories in the design of person-centred web-based supports; 3) The evaluation of the effects of health outcomes for the informants involved and 4) The development of a generic person-centred model for learning and social support for people with long-term illness and their significant others. Person-centred web-based support is a new area and few studies focus on how web-based interventions can contribute to the

  2. Ultrashort laser pulse driven inverse free electron laser accelerator experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moody, J. T.; Anderson, S. G.; Anderson, G.

    In this paper we discuss the ultrashort pulse high gradient Inverse Free Electron laser accelerator experiment carried out at the Lawrence Livermore National Laboratory which demonstrated gra- dients exceeding 200 MV/m using a 4 TW 100 fs long 800 nm Ti:Sa laser pulse. Due to the short laser and electron pulse lengths, synchronization was determined to be one of the main challenges in this experiment. This made necessary the implementation of a single-shot, non destructive, electro-optic sampling based diagnostics to enable time-stamping of each laser accelerator shot with < 100 fs accuracy. The results of this experiment are expected tomore » pave the way towards the development of future GeV-class IFEL accelerators.« less

  3. Ultrashort laser pulse driven inverse free electron laser accelerator experiment

    DOE PAGES

    Moody, J. T.; Anderson, S. G.; Anderson, G.; ...

    2016-02-29

    In this paper we discuss the ultrashort pulse high gradient Inverse Free Electron laser accelerator experiment carried out at the Lawrence Livermore National Laboratory which demonstrated gra- dients exceeding 200 MV/m using a 4 TW 100 fs long 800 nm Ti:Sa laser pulse. Due to the short laser and electron pulse lengths, synchronization was determined to be one of the main challenges in this experiment. This made necessary the implementation of a single-shot, non destructive, electro-optic sampling based diagnostics to enable time-stamping of each laser accelerator shot with < 100 fs accuracy. The results of this experiment are expected tomore » pave the way towards the development of future GeV-class IFEL accelerators.« less

  4. The Particle Accelerator Simulation Code PyORBIT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorlov, Timofey V; Holmes, Jeffrey A; Cousineau, Sarah M

    2015-01-01

    The particle accelerator simulation code PyORBIT is presented. The structure, implementation, history, parallel and simulation capabilities, and future development of the code are discussed. The PyORBIT code is a new implementation and extension of algorithms of the original ORBIT code that was developed for the Spallation Neutron Source accelerator at the Oak Ridge National Laboratory. The PyORBIT code has a two level structure. The upper level uses the Python programming language to control the flow of intensive calculations performed by the lower level code implemented in the C++ language. The parallel capabilities are based on MPI communications. The PyORBIT ismore » an open source code accessible to the public through the Google Open Source Projects Hosting service.« less

  5. Effects of Different Backpack Loads in Acceleration Transmission during Recreational Distance Walking.

    PubMed

    Lucas-Cuevas, Angel G; Pérez-Soriano, Pedro; Bush, Michael; Crossman, Aaron; Llana, Salvador; Cortell-Tormo, Juan M; Pérez-Turpin, José A

    2013-01-01

    It is well established nowadays the benefits that physical activity can have on the health of individuals. Walking is considered a fundamental method of movement and using a backpack is a common and economical manner of carrying load weight. Nevertheless, the shock wave produced by the impact forces when carrying a backpack can have detrimental effects on health status. Therefore, the aim of this study was to investigate differences in the accelerations placed on males and females whilst carrying different loads when walking. Twenty nine sports science students (16 males and 13 females) participated in the study under 3 different conditions: no weight, 10% and 20% body weight (BW) added in a backpack. Accelerometers were attached to the right shank and the centre of the forehead. Results showed that males have lower accelerations than females both in the head (2.62 ± 0.43G compared to 2.83 + 0.47G) and shank (1.37 ± 0.14G compared to 1.52 ± 0.15G; p<0.01). Accelerations for males and females were consistent throughout each backpack condition (p>0.05). The body acts as a natural shock absorber, reducing the amount of force that transmits through the body between the foot (impact point) and head. Anthropometric and body mass distribution differences between males and females may result in women receiving greater impact acceleration compared to men when the same load is carried.

  6. Effects of Different Backpack Loads in Acceleration Transmission during Recreational Distance Walking

    PubMed Central

    Lucas-Cuevas, Angel G.; Pérez-Soriano, Pedro; Bush, Michael; Crossman, Aaron; Llana, Salvador; Cortell-Tormo, Juan M.; Pérez-Turpin, José A.

    It is well established nowadays the benefits that physical activity can have on the health of individuals. Walking is considered a fundamental method of movement and using a backpack is a common and economical manner of carrying load weight. Nevertheless, the shock wave produced by the impact forces when carrying a backpack can have detrimental effects on health status. Therefore, the aim of this study was to investigate differences in the accelerations placed on males and females whilst carrying different loads when walking. Twenty nine sports science students (16 males and 13 females) participated in the study under 3 different conditions: no weight, 10% and 20% body weight (BW) added in a backpack. Accelerometers were attached to the right shank and the centre of the forehead. Results showed that males have lower accelerations than females both in the head (2.62 ± 0.43G compared to 2.83 + 0.47G) and shank (1.37 ± 0.14G compared to 1.52 ± 0.15G; p<0.01). Accelerations for males and females were consistent throughout each backpack condition (p>0.05). The body acts as a natural shock absorber, reducing the amount of force that transmits through the body between the foot (impact point) and head. Anthropometric and body mass distribution differences between males and females may result in women receiving greater impact acceleration compared to men when the same load is carried. PMID:24146708

  7. Building Integrated Pathways to Sustainable Careers: An Introduction to the Accelerated Opportunity Initiative

    ERIC Educational Resources Information Center

    Pleasants, Rachel

    2011-01-01

    "Accelerating Opportunity" responds to the nation's growing need for improved pathways from Adult Basic Education (ABE) to credentials of value in the labor market. It builds on promising practices developed in "Breaking Through," an initiative of Jobs for the Future and the National Council for Workforce Education, and…

  8. Accelerated Schools in Action: Lessons from the Field.

    ERIC Educational Resources Information Center

    Finnan, Christine, Ed.; And Others

    This book provides insights into one of the nation's largest and most comprehensive school-restructuring movements, the Accelerated Schools Project. Since its inception in 1986, the focus of the movement has been on transforming schools with students at risk of dropping out into schools with high expectations of all students. This is accomplished,…

  9. Accelerated Performance Testing on the 2006 NCAT Pavement Test Track

    DOT National Transportation Integrated Search

    2009-12-01

    The original National Center for Asphalt Technology (NCAT) Pavement Test Track was built in 2000 in Opelika, Alabama where it has served as a state-of-the-art, full-scale, closed-loop accelerated loading facility. The construction, operation, and res...

  10. The digital eczema centre utrecht.

    PubMed

    van Os-Medendorp, Harmieke; van Veelen, Carien; Hover, Maaike; Eland-de Kok, Petra; Bruijnzeel-Koomen, Carla; Sonnevelt, Gert-Jan; Mensing, Geert; Pasmans, Suzanne

    2010-01-01

    The University Medical Centre Utrecht (UMC Utrecht) has developed an eczema portal that combines e-consulting, monitoring and self-management training by a dermatology nurse online for patients and parents of young children with atopic dermatitis (AD). Patient satisfaction with the portal was high. It could be extended to become a Digital Eczema Centre for multidisciplinary collaboration between health-care providers from different locations and the patient. Before starting the construction of the Digital Eczema Centre, the feasibility was examined by carrying out a business case analysis. The purposes, strength and weaknesses showed that the Digital Eczema Centre offered opportunities to improve care for patients with AD. The financial analysis resulted in a medium/best case scenario with a positive result of euro50-240,000 over a period of five years. We expect that the Digital Eczema Centre will increase the accessibility and quality of care. The web-based patient record and the digital chain-of-care promote the involvement of patients, parents and multidisciplinary teams as well as the continuity and coordination of care.

  11. Community Petascale Project for Accelerator Science and Simulation: Advancing Computational Science for Future Accelerators and Accelerator Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spentzouris, P.; /Fermilab; Cary, J.

    The design and performance optimization of particle accelerators are essential for the success of the DOE scientific program in the next decade. Particle accelerators are very complex systems whose accurate description involves a large number of degrees of freedom and requires the inclusion of many physics processes. Building on the success of the SciDAC-1 Accelerator Science and Technology project, the SciDAC-2 Community Petascale Project for Accelerator Science and Simulation (ComPASS) is developing a comprehensive set of interoperable components for beam dynamics, electromagnetics, electron cooling, and laser/plasma acceleration modelling. ComPASS is providing accelerator scientists the tools required to enable the necessarymore » accelerator simulation paradigm shift from high-fidelity single physics process modeling (covered under SciDAC1) to high-fidelity multiphysics modeling. Our computational frameworks have been used to model the behavior of a large number of accelerators and accelerator R&D experiments, assisting both their design and performance optimization. As parallel computational applications, the ComPASS codes have been shown to make effective use of thousands of processors. ComPASS is in the first year of executing its plan to develop the next-generation HPC accelerator modeling tools. ComPASS aims to develop an integrated simulation environment that will utilize existing and new accelerator physics modules with petascale capabilities, by employing modern computing and solver technologies. The ComPASS vision is to deliver to accelerator scientists a virtual accelerator and virtual prototyping modeling environment, with the necessary multiphysics, multiscale capabilities. The plan for this development includes delivering accelerator modeling applications appropriate for each stage of the ComPASS software evolution. Such applications are already being used to address challenging problems in accelerator design and optimization. The Com

  12. Simulation prediction and experiment setup of vacuum laser acceleration at Brookhaven National Lab-Accelerator Test Facility

    NASA Astrophysics Data System (ADS)

    Shao, L.; Cline, D.; Ding, X.; Ho, Y. K.; Kong, Q.; Xu, J. J.; Pogorelsky, I.; Yakimenko, V.; Kusche, K.

    2013-02-01

    This paper presents the pre-experiment plan and prediction of the first stage of vacuum laser acceleration (VLA) collaborating by UCLA, Fudan University and ATF-BNL. This first stage experiment is a proof-of-principle to support our previously posted novel VLA theory. Simulations show that based on ATF's current experimental conditions the electron beam with initial energy of 15 MeV can get net energy gain from an intense CO2 laser beam. The difference in electron beam energy spread is observable by the ATF beam line diagnostics system. Further, this energy spread expansion effect increases along with an increase in laser intensity. The proposal has been approved by the ATF committee and the experiment will be our next project.

  13. Teaching and Learning Centres: Towards Maturation

    ERIC Educational Resources Information Center

    Challis, Di; Holt, Dale; Palmer, Stuart

    2009-01-01

    Approximately 70% of Australian Teaching and Learning Centres have been restructured and/or have undergone leadership changes in the last three years. The volatility of this environment reflects the number of significant challenges faced by Teaching and Learning Centres. In determining what makes Centres successful, the issues that are likely to…

  14. "DIANA" - A New, Deep-Underground Accelerator Facility for Astrophysics Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leitner, M.; Leitner, D.; Lemut, A.

    2009-05-28

    The DIANA project (Dakota Ion Accelerators for Nuclear Astrophysics) is a collaboration between the University of Notre Dame, University of North Carolina, Western Michigan University, and Lawrence Berkeley National Laboratory to build a nuclear astrophysics accelerator facility 1.4 km below ground. DIANA is part of the US proposal DUSEL (Deep Underground Science and Engineering Laboratory) to establish a cross-disciplinary underground laboratory in the former gold mine of Homestake in South Dakota, USA. DIANA would consist of two high-current accelerators, a 30 to 400 kV variable, high-voltage platform, and a second, dynamitron accelerator with a voltage range of 350 kV tomore » 3 MV. As a unique feature, both accelerators are planned to be equipped with either high-current microwave ion sources or multi-charged ECR ion sources producing ions from protons to oxygen. Electrostatic quadrupole transport elements will be incorporated in the dynamitron high voltage column. Compared to current astrophysics facilities, DIANA could increase the available beam densities on target by magnitudes: up to 100 mA on the low energy accelerator and several mA on the high energy accelerator. An integral part of the DIANA project is the development of a high-density super-sonic gas-jet target which can handle these anticipated beam powers. The paper will explain the main components of the DIANA accelerators and their beam transport lines and will discuss related technical challenges.« less

  15. Accelerators, Beams And Physical Review Special Topics - Accelerators And Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siemann, R.H.; /SLAC

    Accelerator science and technology have evolved as accelerators became larger and important to a broad range of science. Physical Review Special Topics - Accelerators and Beams was established to serve the accelerator community as a timely, widely circulated, international journal covering the full breadth of accelerators and beams. The history of the journal and the innovations associated with it are reviewed.

  16. Theory-based practice in a major medical centre.

    PubMed

    Alligood, Martha Raile

    2011-11-01

    This project was designed to improve care quality and nursing staff satisfaction. Nursing theory structures thought and action as demonstrated by evidence of improvement in complex health-care settings. Nursing administrators selected Modelling and Role-Modelling (MRM) for the theory-based practice goal in their strategic plan. An action research approach structured implementation of MRM in a 1-year consultation project in 2001-2002. Quality of health care improved according to national quality assessment ratings, as well as patient satisfaction and nurse satisfaction. Modelling and Role-Modelling demonstrated capacity to structure nursing thought and action in patient care in a major medical centre. Uniformity of patient care language was valued by nurses as well as by allied health providers who wished to learn the holistic MRM style of practice. The processes of MRM and action research contributed to project success. A positive health-care change project was carried out in a large medical centre with action research. Introducing MRM theory-based practice was a beneficial decision by nursing administration that improved care and nurse satisfaction. Attention to nursing practice stimulated career development among the nurses to pursue bachelors, masters, and doctoral degrees. © 2011 Blackwell Publishing Ltd.

  17. Small Steps towards Student-Centred Learning

    ERIC Educational Resources Information Center

    Jacobs, George M.; Toh-Heng, Hwee Leng

    2013-01-01

    Student centred learning classroom practices are contrasted with those in teacher centred learning classrooms. The discussion focuses on the theoretical underpinnings of the former, and provides nine steps and tips on how to implement student centred learning strategies, with the aim of developing the 21st century skills of self-directed and…

  18. Commnity Petascale Project for Accelerator Science And Simulation: Advancing Computational Science for Future Accelerators And Accelerator Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spentzouris, Panagiotis; /Fermilab; Cary, John

    The design and performance optimization of particle accelerators are essential for the success of the DOE scientific program in the next decade. Particle accelerators are very complex systems whose accurate description involves a large number of degrees of freedom and requires the inclusion of many physics processes. Building on the success of the SciDAC-1 Accelerator Science and Technology project, the SciDAC-2 Community Petascale Project for Accelerator Science and Simulation (ComPASS) is developing a comprehensive set of interoperable components for beam dynamics, electromagnetics, electron cooling, and laser/plasma acceleration modelling. ComPASS is providing accelerator scientists the tools required to enable the necessarymore » accelerator simulation paradigm shift from high-fidelity single physics process modeling (covered under SciDAC1) to high-fidelity multiphysics modeling. Our computational frameworks have been used to model the behavior of a large number of accelerators and accelerator R&D experiments, assisting both their design and performance optimization. As parallel computational applications, the ComPASS codes have been shown to make effective use of thousands of processors.« less

  19. Development of a 20 MeV Dielectric-Loaded Test Accelerator

    NASA Astrophysics Data System (ADS)

    Gold, Steven H.; Kinkead, Allen K.; Gai, Wei; Power, John G.; Konecny, Richard; Jing, Chunguang; Long, Jidong; Tantawi, Sami G.; Nantista, Christopher D.; Bruce, Ralph W.; Fliflet, Arne W.; Lombardi, Marcie; Lewis, David

    2006-11-01

    This paper presents a progress report on a joint project by the Naval Research Laboratory (NRL) and Argonne National Laboratory (ANL), in collaboration with the Stanford Linear Accelerator Center (SLAC), to develop a dielectric-loaded test accelerator in the magnicon facility at NRL. The accelerator will be powered by an experimental 11.424-GHz magnicon amplifier that presently produces 25 MW of output power in a ˜250-ns pulse at up to 10 Hz. The accelerator will include a 5-MeV electron injector originally developed at the Tsinghua University in Beijing, China, and can incorporate DLA structures up to 0.5 m in length. The DLA structures are being developed by ANL, and shorter test structures fabricated from a variety of dielectric materials have undergone testing at NRL at gradients up to ˜8 MV/m. SLAC has developed components to distribute the power from the two magnicon output arms to the injector and to the DLA accelerating structure with separate control of the power ratio and relative phase. RWBruce Associates, Inc., working with NRL, has investigated means to join short ceramic sections into a continuous accelerator tube by a brazing process using an intense 83-GHz beam. The installation and testing of the first dielectric-loaded test accelerator, including injector, DLA test structure, and spectrometer, should take place within the next year.

  20. Essay: Robert H. Siemann As Leader of the Advanced Accelerator Research Department

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colby, Eric R.; Hogan, Mark J.; /SLAC

    Robert H. Siemann originally conceived of the Advanced Accelerator Research Department (AARD) as an academic, experimental group dedicated to probing the technical limitations of accelerators while providing excellent educational opportunities for young scientists. The early years of the Accelerator Research Department B, as it was then known, were dedicated to a wealth of mostly student-led experiments to examine the promise of advanced accelerator techniques. High-gradient techniques including millimeter-wave rf acceleration, beam-driven plasma acceleration, and direct laser acceleration were pursued, including tests of materials under rf pulsed heating and short-pulse laser radiation, to establish the ultimate limitations on gradient. As themore » department and program grew, so did the motivation to found an accelerator research center that brought experimentalists together in a test facility environment to conduct a broad range of experiments. The Final Focus Test Beam and later the Next Linear Collider Test Accelerator provided unique experimental facilities for AARD staff and collaborators to carry out advanced accelerator experiments. Throughout the evolution of this dynamic program, Bob maintained a department atmosphere and culture more reminiscent of a university research group than a national laboratory department. His exceptional ability to balance multiple roles as scientist, professor, and administrator enabled the creation and preservation of an environment that fostered technical innovation and scholarship.« less

  1. Towards the Implementation of an Assessment-Centred Blended Learning Framework at the Course Level: A Case Study in a Vietnamese National University

    ERIC Educational Resources Information Center

    Nguyen, Viet Anh

    2017-01-01

    Purpose: The purpose of this paper is to build an assessment-centred blended learning (BL) framework to assess learners, to analyse and to evaluate the impact of the technology support in the form of formative assessment in students' positive learning. Design/methodology/approach: This research proposed an assessment-centred BL framework at the…

  2. A cross-sectional study on person-centred communication in the care of older people: the COMHOME study protocol

    PubMed Central

    Hafskjold, Linda; Sundler, Annelie J; Holmström, Inger K; Sundling, Vibeke; van Dulmen, Sandra

    2015-01-01

    Introduction This paper presents an international cross-sectional study on person-centred communication with older people receiving healthcare (COMHOME). Person-centred care relies on effective communication, but few studies have explored this with a specific focus on older people. The main aim of the COMHOME study is to generate knowledge on person-centred communication with older people (>65 years) in home healthcare services, radiographic and optometric practice. Methods and analysis This study will explore the communication between care providers and older persons in home care services. Home healthcare visits will be audiorecorded (n=500) in Norway, the Netherlands and Sweden. Analyses will be performed with the Verona Coding Definitions for Emotional Sequences (VR-CoDES), the Roter Interaction Analysis System (RIAS) and qualitative methods. The content of the communication, communicative challenging situations as well as empathy, power distance, decision-making, preservation of dignity and respect will be explored. In Norway, an additional 100 encounters, 50 in optometric practice (video recorded) and 50 in radiographic practice (audiorecorded), will be analysed. Furthermore, healthcare providers’ self-reported communication skills, empathy, mindfulness and emotional intelligence in relation to observed person-centred communication skills will be assessed using well-established standardised instruments. Ethics and dissemination Depending on national legislation, approval of either the central ethical committees (eg, nation or university), the national data protection officials or the local ethical committees (eg, units of home healthcare) was obtained. Study findings will be disseminated widely through peer-reviewed publications and conference presentations. The research findings will add knowledge to improve services provided to this vulnerable group of patients. Additionally, the findings will underpin a training programme for healthcare students and

  3. A cross-sectional study on person-centred communication in the care of older people: the COMHOME study protocol.

    PubMed

    Hafskjold, Linda; Sundler, Annelie J; Holmström, Inger K; Sundling, Vibeke; van Dulmen, Sandra; Eide, Hilde

    2015-04-15

    This paper presents an international cross-sectional study on person-centred communication with older people receiving healthcare (COMHOME). Person-centred care relies on effective communication, but few studies have explored this with a specific focus on older people. The main aim of the COMHOME study is to generate knowledge on person-centred communication with older people (>65 years) in home healthcare services, radiographic and optometric practice. This study will explore the communication between care providers and older persons in home care services. Home healthcare visits will be audiorecorded (n=500) in Norway, the Netherlands and Sweden. Analyses will be performed with the Verona Coding Definitions for Emotional Sequences (VR-CoDES), the Roter Interaction Analysis System (RIAS) and qualitative methods. The content of the communication, communicative challenging situations as well as empathy, power distance, decision-making, preservation of dignity and respect will be explored. In Norway, an additional 100 encounters, 50 in optometric practice (video recorded) and 50 in radiographic practice (audiorecorded), will be analysed. Furthermore, healthcare providers' self-reported communication skills, empathy, mindfulness and emotional intelligence in relation to observed person-centred communication skills will be assessed using well-established standardised instruments. Depending on national legislation, approval of either the central ethical committees (eg, nation or university), the national data protection officials or the local ethical committees (eg, units of home healthcare) was obtained. Study findings will be disseminated widely through peer-reviewed publications and conference presentations. The research findings will add knowledge to improve services provided to this vulnerable group of patients. Additionally, the findings will underpin a training programme for healthcare students and care providers focusing on communication with older people

  4. A Healing Space: The Experiences of First Nations and Inuit Youth with Equine-Assisted Learning (EAL)

    ERIC Educational Resources Information Center

    Dell, Colleen Anne; Chalmers, Darlene; Bresette, Nora; Swain, Sue; Rankin, Deb; Hopkins, Carol

    2011-01-01

    The Nimkee NupiGawagan Healing Centre (NNHC) in Muncey, ON provides residential treatment to First Nations and Inuit youth who abuse solvents. As a complement to its culture-based programming, in 2008 the centre began offering weekly equine-assisted learning (EAL) curriculum to its clients in partnership with the Keystone Equine Centre and the…

  5. Can Chemistry Teachers' Centres Survive?

    ERIC Educational Resources Information Center

    Garforth, F. M.

    1972-01-01

    The difficulties faced by the Hull Chemistry Teachers' Centre in England are discussed. The lack of finances and time, as well as organizational difficulties in relationship with Science Centres and universities are among the problems. (TS)

  6. Fermilab | Tevatron | Accelerator

    Science.gov Websites

    Leading accelerator technology Accelerator complex Illinois Accelerator Research Center Fermilab temperature. They were used to transfer particles from one part of the Fermilab accelerator complex to another center ring of Fermilab's accelerator complex. Before the Tevatron shut down, it had three primary

  7. A new risk prediction model for critical care: the Intensive Care National Audit & Research Centre (ICNARC) model.

    PubMed

    Harrison, David A; Parry, Gareth J; Carpenter, James R; Short, Alasdair; Rowan, Kathy

    2007-04-01

    To develop a new model to improve risk prediction for admissions to adult critical care units in the UK. Prospective cohort study. The setting was 163 adult, general critical care units in England, Wales, and Northern Ireland, December 1995 to August 2003. Patients were 216,626 critical care admissions. None. The performance of different approaches to modeling physiologic measurements was evaluated, and the best methods were selected to produce a new physiology score. This physiology score was combined with other information relating to the critical care admission-age, diagnostic category, source of admission, and cardiopulmonary resuscitation before admission-to develop a risk prediction model. Modeling interactions between diagnostic category and physiology score enabled the inclusion of groups of admissions that are frequently excluded from risk prediction models. The new model showed good discrimination (mean c index 0.870) and fit (mean Shapiro's R 0.665, mean Brier's score 0.132) in 200 repeated validation samples and performed well when compared with recalibrated versions of existing published risk prediction models in the cohort of patients eligible for all models. The hypothesis of perfect fit was rejected for all models, including the Intensive Care National Audit & Research Centre (ICNARC) model, as is to be expected in such a large cohort. The ICNARC model demonstrated better discrimination and overall fit than existing risk prediction models, even following recalibration of these models. We recommend it be used to replace previously published models for risk adjustment in the UK.

  8. Global National Qualifications Framework Inventory

    ERIC Educational Resources Information Center

    Bjornavold, Jens; Pevec-Grm, Slava; Graham, Michael; Deij, Arjen; Singh, Madhu; Charkoun, Borhène; Agrawal, Shivani

    2013-01-01

    This publication is a global, country-by-country, inventory of National Qualifications Frameworks (NQFs). It is a copublication, prepared by two EU agencies, the European Training Foundation (ETF) and the Centre for the Development of Vocational Training (Cedefop); and UNESCO's Institute for Lifelong Learning (UIL) and the Section for TVET at…

  9. Model Diagnostics for the Department of Energy's Accelerated Climate Modeling for Energy (ACME) Project

    NASA Astrophysics Data System (ADS)

    Smith, B.

    2015-12-01

    In 2014, eight Department of Energy (DOE) national laboratories, four academic institutions, one company, and the National Centre for Atmospheric Research combined forces in a project called Accelerated Climate Modeling for Energy (ACME) with the goal to speed Earth system model development for climate and energy. Over the planned 10-year span, the project will conduct simulations and modeling on DOE's most powerful high-performance computing systems at Oak Ridge, Argonne, and Lawrence Berkeley Leadership Compute Facilities. A key component of the ACME project is the development of an interactive test bed for the advanced Earth system model. Its execution infrastructure will accelerate model development and testing cycles. The ACME Workflow Group is leading the efforts to automate labor-intensive tasks, provide intelligent support for complex tasks and reduce duplication of effort through collaboration support. As part of this new workflow environment, we have created a diagnostic, metric, and intercomparison Python framework, called UVCMetrics, to aid in the testing-to-production execution of the ACME model. The framework exploits similarities among different diagnostics to compactly support diagnosis of new models. It presently focuses on atmosphere and land but is designed to support ocean and sea ice model components as well. This framework is built on top of the existing open-source software framework known as the Ultrascale Visualization Climate Data Analysis Tools (UV-CDAT). Because of its flexible framework design, scientists and modelers now can generate thousands of possible diagnostic outputs. These diagnostics can compare model runs, compare model vs. observation, or simply verify a model is physically realistic. Additional diagnostics are easily integrated into the framework, and our users have already added several. Diagnostics can be generated, viewed, and manipulated from the UV-CDAT graphical user interface, Python command line scripts and programs

  10. rf breakdown tests of mm-wave metallic accelerating structures

    DOE PAGES

    Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon; ...

    2016-01-06

    In this study, we explore the physics and frequency-scaling of vacuum rf breakdowns at sub-THz frequencies. We present the experimental results of rf tests performed in metallic mm-wave accelerating structures. These experiments were carried out at the facility for advanced accelerator experimental tests (FACET) at the SLAC National Accelerator Laboratory. The rf fields were excited by the FACET ultrarelativistic electron beam. We compared the performances of metal structures made with copper and stainless steel. The rf frequency of the fundamental accelerating mode, propagating in the structures at the speed of light, varies from 115 to 140 GHz. The traveling wavemore » structures are 0.1 m long and composed of 125 coupled cavities each. We determined the peak electric field and pulse length where the structures were not damaged by rf breakdowns. We calculated the electric and magnetic field correlated with the rf breakdowns using the FACET bunch parameters. The wakefields were calculated by a frequency domain method using periodic eigensolutions. Such a method takes into account wall losses and is applicable to a large variety of geometries. The maximum achieved accelerating gradient is 0.3 GV/m with a peak surface electric field of 1.5 GV/m and a pulse length of about 2.4 ns.« less

  11. Piezoelectric particle accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kemp, Mark A.; Jongewaard, Erik N.; Haase, Andrew A.

    2017-08-29

    A particle accelerator is provided that includes a piezoelectric accelerator element, where the piezoelectric accelerator element includes a hollow cylindrical shape, and an input transducer, where the input transducer is disposed to provide an input signal to the piezoelectric accelerator element, where the input signal induces a mechanical excitation of the piezoelectric accelerator element, where the mechanical excitation is capable of generating a piezoelectric electric field proximal to an axis of the cylindrical shape, where the piezoelectric accelerator is configured to accelerate a charged particle longitudinally along the axis of the cylindrical shape according to the piezoelectric electric field.

  12. Accelerating Scientific Advancement for Pediatric Rare Lung Disease Research. Report from a National Institutes of Health–NHLBI Workshop, September 3 and 4, 2015

    PubMed Central

    Young, Lisa R.; Trapnell, Bruce C.; Mandl, Kenneth D.; Swarr, Daniel T.; Wambach, Jennifer A.

    2016-01-01

    Pediatric rare lung disease (PRLD) is a term that refers to a heterogeneous group of rare disorders in children. In recent years, this field has experienced significant progress marked by scientific discoveries, multicenter and interdisciplinary collaborations, and efforts of patient advocates. Although genetic mechanisms underlie many PRLDs, pathogenesis remains uncertain for many of these disorders. Furthermore, epidemiology and natural history are insufficiently defined, and therapies are limited. To develop strategies to accelerate scientific advancement for PRLD research, the NHLBI of the National Institutes of Health convened a strategic planning workshop on September 3 and 4, 2015. The workshop brought together a group of scientific experts, intramural and extramural investigators, and advocacy groups with the following objectives: (1) to discuss the current state of PRLD research; (2) to identify scientific gaps and barriers to increasing research and improving outcomes for PRLDs; (3) to identify technologies, tools, and reagents that could be leveraged to accelerate advancement of research in this field; and (4) to develop priorities for research aimed at improving patient outcomes and quality of life. This report summarizes the workshop discussion and provides specific recommendations to guide future research in PRLD. PMID:27925785

  13. Accelerating Scientific Advancement for Pediatric Rare Lung Disease Research. Report from a National Institutes of Health-NHLBI Workshop, September 3 and 4, 2015.

    PubMed

    Young, Lisa R; Trapnell, Bruce C; Mandl, Kenneth D; Swarr, Daniel T; Wambach, Jennifer A; Blaisdell, Carol J

    2016-12-01

    Pediatric rare lung disease (PRLD) is a term that refers to a heterogeneous group of rare disorders in children. In recent years, this field has experienced significant progress marked by scientific discoveries, multicenter and interdisciplinary collaborations, and efforts of patient advocates. Although genetic mechanisms underlie many PRLDs, pathogenesis remains uncertain for many of these disorders. Furthermore, epidemiology and natural history are insufficiently defined, and therapies are limited. To develop strategies to accelerate scientific advancement for PRLD research, the NHLBI of the National Institutes of Health convened a strategic planning workshop on September 3 and 4, 2015. The workshop brought together a group of scientific experts, intramural and extramural investigators, and advocacy groups with the following objectives: (1) to discuss the current state of PRLD research; (2) to identify scientific gaps and barriers to increasing research and improving outcomes for PRLDs; (3) to identify technologies, tools, and reagents that could be leveraged to accelerate advancement of research in this field; and (4) to develop priorities for research aimed at improving patient outcomes and quality of life. This report summarizes the workshop discussion and provides specific recommendations to guide future research in PRLD.

  14. EDITORIAL: Laser and plasma accelerators Laser and plasma accelerators

    NASA Astrophysics Data System (ADS)

    Bingham, Robert

    2009-02-01

    This special issue on laser and plasma accelerators illustrates the rapid advancement and diverse applications of laser and plasma accelerators. Plasma is an attractive medium for particle acceleration because of the high electric field it can sustain, with studies of acceleration processes remaining one of the most important areas of research in both laboratory and astrophysical plasmas. The rapid advance in laser and accelerator technology has led to the development of terawatt and petawatt laser systems with ultra-high intensities and short sub-picosecond pulses, which are used to generate wakefields in plasma. Recent successes include the demonstration by several groups in 2004 of quasi-monoenergetic electron beams by wakefields in the bubble regime with the GeV energy barrier being reached in 2006, and the energy doubling of the SLAC high-energy electron beam from 42 to 85 GeV. The electron beams generated by the laser plasma driven wakefields have good spatial quality with energies ranging from MeV to GeV. A unique feature is that they are ultra-short bunches with simulations showing that they can be as short as a few femtoseconds with low-energy spread, making these beams ideal for a variety of applications ranging from novel high-brightness radiation sources for medicine, material science and ultrafast time-resolved radiobiology or chemistry. Laser driven ion acceleration experiments have also made significant advances over the last few years with applications in laser fusion, nuclear physics and medicine. Attention is focused on the possibility of producing quasi-mono-energetic ions with energies ranging from hundreds of MeV to GeV per nucleon. New acceleration mechanisms are being studied, including ion acceleration from ultra-thin foils and direct laser acceleration. The application of wakefields or beat waves in other areas of science such as astrophysics and particle physics is beginning to take off, such as the study of cosmic accelerators considered

  15. Shielding for High-Energy Electron Accelerator Installations. National Bureau of Standards Handbook 97.

    ERIC Educational Resources Information Center

    National Bureau of Standards (DOC), Washington, DC.

    Recommendations for radiation shielding, protection, and measurement are presented. This handbook is an extension of previous recommendations for protection against radiation from--(1) high energy and power electron accelerators, (2) food processing equipment, and (3) general sterilization equipment. The new recommendations are concerned with…

  16. Managing the technological edge: the UNESCO International Computation Centre and the limits to the transfer of computer technology, 1946-61.

    PubMed

    Nofre, David

    2014-07-01

    The spread of the modern computer is assumed to have been a smooth process of technology transfer. This view relies on an assessment of the open circulation of knowledge ensured by the US and British governments in the early post-war years. This article presents new historical evidence that question this view. At the centre of the article lies the ill-fated establishment of the UNESCO International Computation Centre. The project was initially conceived in 1946 to provide advanced computation capabilities to scientists of all nations. It soon became a prize sought by Western European countries like The Netherlands and Italy seeking to speed up their own national research programs. Nonetheless, as the article explains, the US government's limitations on the research function of the future centre resulted in the withdrawal of European support for the project. These limitations illustrate the extent to which US foreign science policy could operate as (stealth) industrial policy to secure a competitive technological advantage and the prospects of US manufacturers in a future European market.

  17. Saskatchewan Forest Fire Control Centre Surface Meteorological Data

    NASA Technical Reports Server (NTRS)

    Hall, Forrest G. (Editor); Newcomer, Jeffrey A. (Editor); Funk, Barry; Strub, Richard

    2000-01-01

    The Saskatchewan Forest Fire Control Centre (SFFCC) provided surface meteorological data to BOREAS from its archive. This data set contains hourly surface meteorological data from 18 of the Meteorological stations located across Saskatchewan. Included in these data are parameters of date, time, temperature, relative humidity, wind direction, wind speed, and precipitation. Temporally, the data cover the period of May through September of 1994 and 1995. The data are provided in comma-delimited ASCII files, and are classified as AFM-Staff data. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

  18. First Results from the Cornell COBRA Accelerator for Light Ion ICF Research

    NASA Astrophysics Data System (ADS)

    Lindholm, F.; Krastelev, E. G.; Greenly, J. B.; Kusse, B. R.

    1996-11-01

    COBRA, the Cornell Beam Research Accelerator, is a four-stage linear induction adder based on the Sandia National Laboratories SABRE accelerator design. The full 4 × 1 MV, 200 kA, 40 ns COBRA was completed in June 1996, after a year of initial operation with a single stage. Accelerator operation will be described, and first experimental results of power coupling and ion beam generation using a closely-coupled (short MITL) applied-B extraction ion diode load will be presented. A diagnostic package for beam optics including local microdivergence and aiming measurements is being developed, and results from both the single-stage experiments and new experiments on the full accelerator will be presented. A 20 ns, 15% voltage precursor to the main pulse resulting from coupling through the nonlinear magnetization characteristic of the Metglas^circR core at high magnetization rate was seen in the single-cell experiments. This mechanism will be discussed and its consequences on the full accelerator will be investigated.

  19. Correlation of Noise Signature to Pulsed Power Events at the HERMES III Accelerator.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Barbara; Joseph, Nathan Ryan; Salazar, Juan Diego

    2016-11-01

    The HERMES III accelerator, which is located at Sandia National Laboratories' Tech Area IV, is the largest pulsed gamma X-ray source in the world. The accelerator is made up of 20 inductive cavities that are charged to 1 MV each by complex pulsed power circuitry. The firing time of the machine components ranges between the microsecond and nanosecond timescales. This results in a variety of electromagnetic frequencies when the accelerator fires. Testing was done to identify the HERMES electromagnetic noise signal and to map it to the various accelerator trigger events. This report will show the measurement methods used tomore » capture the noise spectrum produced from the machine and correlate this noise signature with machine events.« less

  20. University of Victoria Genome British Columbia Proteomics Centre Partners with CPTAC | Office of Cancer Clinical Proteomics Research

    Cancer.gov

    University of Victoria Genome British Columbia Proteomics Centre, a leader in proteomic technology development, has partnered with the U.S. National Cancer Institute (NCI) to make targeted proteomic assays accessible to the community through NCI’s CPTAC Assay Portal (https://assays.cancer.gov).

  1. Experiences with the implementation of a national teaching qualification in university medical centres and veterinary medicine in the Netherlands.

    PubMed

    Molenaar, Willemina M Ineke; Zanting, Anneke

    2015-02-01

    In 2008, a compulsory national basic teaching qualification was introduced for all university teachers in the Netherlands. At that time all eight University Medical Centres (UMCs) and the only Faculty of Veterinary Medicine had adopted or were setting up teacher development programmes. This study explores how these programmes relate to each other and to the basic teaching qualification. To gather information on teacher development programmes in the UMCs and the Veterinary Medicine Faculty an online survey was filled out by teacher development representatives from each of them. The programmes had main features in common (e.g. competency based and portfolio assessment), but differed somewhat in contents according to the local situation. Importantly, they had all been formally accepted as equivalent to the basic teaching qualification. We consider the freedom to tailor the qualifications to the medical context as well as to the local situation of the UMCs and the Veterinary Medicine Faculty one of the major success factors and the well-established collaboration between teacher development representatives of the UMCs and the Faculty of Veterinary Medicine as another. Challenges for the future include embedding the teacher development programmes in the institutional organizations and maintaining and further developing the programmes and the competencies of the qualified teachers, e.g. in a senior qualification.

  2. A beamline systems model for Accelerator-Driven Transmutation Technology (ADTT) facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todd, A.M.M.; Paulson, C.C.; Peacock, M.A.

    1995-10-01

    A beamline systems code, that is being developed for Accelerator-Driven Transmutation Technology (ADTT) facility trade studies, is described. The overall program is a joint Grumman, G.H. Gillespie Associates (GHGA) and Los Alamos National Laboratory effort. The GHGA Accelerator Systems Model (ASM) has been adopted as the framework on which this effort is based. Relevant accelerator and beam transport models from earlier Grumman systems codes are being adapted to this framework. Preliminary physics and engineering models for each ADTT beamline component have been constructed. Examples noted include a Bridge Coupled Drift Tube Linac (BCDTL) and the accelerator thermal system. A decisionmore » has been made to confine the ASM framework principally to beamline modeling, while detailed target/blanket, balance-of-plant and facility costing analysis will be performed externally. An interfacing external balance-of-plant and facility costing model, which will permit the performance of iterative facility trade studies, is under separate development. An ABC (Accelerator Based Conversion) example is used to highlight the present models and capabilities.« less

  3. A beamline systems model for Accelerator-Driven Transmutation Technology (ADTT) facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todd, Alan M. M.; Paulson, C. C.; Peacock, M. A.

    1995-09-15

    A beamline systems code, that is being developed for Accelerator-Driven Transmutation Technology (ADTT) facility trade studies, is described. The overall program is a joint Grumman, G. H. Gillespie Associates (GHGA) and Los Alamos National Laboratory effort. The GHGA Accelerator Systems Model (ASM) has been adopted as the framework on which this effort is based. Relevant accelerator and beam transport models from earlier Grumman systems codes are being adapted to this framework. Preliminary physics and engineering models for each ADTT beamline component have been constructed. Examples noted include a Bridge Coupled Drift Tube Linac (BCDTL) and the accelerator thermal system. Amore » decision has been made to confine the ASM framework principally to beamline modeling, while detailed target/blanket, balance-of-plant and facility costing analysis will be performed externally. An interfacing external balance-of-plant and facility costing model, which will permit the performance of iterative facility trade studies, is under separate development. An ABC (Accelerator Based Conversion) example is used to highlight the present models and capabilities.« less

  4. Optical Diagnostics for Plasma-based Particle Accelerators

    NASA Astrophysics Data System (ADS)

    Muggli, Patric

    2009-05-01

    One of the challenges for plasma-based particle accelerators is to measure the spatio-temporal characteristics of the accelerated particle bunch. ``Optical'' diagnostics are particularly interesting and useful because of the large number of techniques that exits to determine the properties of photon pulses. The accelerated bunch can produce photons pulses that carry information about its characteristics for example through synchrotron radiation in a magnet, Cherenkov radiation in a gas, and transition radiation (TR) at the boundary between two media with different dielectric constants. Depending on the wavelength of the emission when compared to the particle bunch length, the radiation can be incoherent or coherent. Incoherent TR in the optical range (or OTR) is useful to measure the transverse spatial characteristics of the beam, such as charge distribution and size. Coherent TR (or CTR) carries information about the bunch length that can in principle be retrieved by standard auto-correlation or interferometric techniques, as well as by spectral measurements. A measurement of the total CTR energy emitted by bunches with constant charge can also be used as a shot-to-shot measurement for the relative bunch length as the CTR energy is proportional to the square of the bunch population and inversely proportional to its length (for a fixed distribution). Spectral interferometry can also yield the spacing between bunches in the case where multiple bunches are trapped in subsequent buckets of the plasma wave. Cherenkov radiation can be used as an energy threshold diagnostic for low energy particles. Cherenkov, synchrotron and transition radiation can be used in a dispersive section of the beam line to measure the bunch energy spectrum. The application of these diagnostics to plasma-based particle accelerators, with emphasis on the beam-driven, plasma wakefield accelerator (PWFA) at the SLAC National Accelerator Laboratory will be discussed.

  5. The paediatric cardiac centre for Africa--proceedings of the March 2012 symposium.

    PubMed

    Kinsley, Robin H; Edwin, Frank; Entsua-Mensah, Kow

    2013-04-01

    The Pediatric Cardiac Centre for Africa (PCCA) was opened by national patron Mr Nelson Mandela on November 7, 2003. In 2008, the Centre's international pediatric cardiac symposium was introduced as a learning forum for pediatric cardiac surgeons and cardiologists in the continent. The symposium has consistently grown in attendance and attracted distinguished leaders in the field. The 2012 symposium featured Dr. Thomas Spray of Children's Hospital of Philadelphia, Dr. David Barron of Birmingham Children's Hospital, and Dr. John Brown of Indiana University School of Medicine as guest speakers. Experience of the Fontan procedure, the small aortic root, hypoplastic left heart syndrome, right ventricular outflow tract reconstruction, transposition of the great arteries, and interrupted aortic arch were the highlights of the symposium. In the "African Corner," centers in South Africa, Ghana, and Angola presented work done from across the African continent.

  6. Building the Petascale National Environmental Research Interoperability Data Platform (NERDIP): Minimizing the 'Trough of Disillusionment' and Accelerating Pathways to the 'Plateau of Productivity'

    NASA Astrophysics Data System (ADS)

    Wyborn, L. A.; Evans, B. J. K.

    2015-12-01

    The National Computational Infrastructure (NCI) at the Australian National University (ANU) has evolved to become Australia's peak computing centre for national computational and Data-intensive Earth system science. More recently NCI collocated 10 Petabytes of 34 major national and international environmental, climate, earth system, geophysics and astronomy data collections to create the National Environmental Research Interoperability Data Platform (NERDIP). Spatial scales of the collections range from global to local ultra-high resolution, whilst sizes range from 3PB down to a few GB. The data is highly connected to both NCI HPC and cloud resources via low latency internal networks with massive bandwidth. Now that the collections are collocated on a single data platform, the 'Hype' and expectations around potential use cases for the NERDIP are high. Not unexpected issues are emerging such as access, licensing issues, ownership, and incompatible data standards. Many communities are standardised within their domain, but achieving true interdisciplinary science will require all communities to move towards open interoperable data formats such as NetCDF4/HDF5. This transition will impact on software using proprietary or non-open standards. But before we reach the 'Plateau of Productivity', there needs to be greater 'Enlightenment' of users to encourage them to realise that this unprecedented Earth system science platform provides a rich mine of opportunities for discovery and innovation for a diverse range of both domain-specific and interdisciplinary investigations including climate and weather research, impact analysis, environment, remote sensing and geophysics and develop new and innovative interdisciplinary use cases that will guide those architecting the system and help minimise the amplitude of the 'Trough of Disillusionment' and ensure greater productivity and uptake of the collections that make NERDIP unique in the next generation of Data-intensive Science.

  7. Source-to-accelerator quadrupole matching section for a compact linear accelerator

    NASA Astrophysics Data System (ADS)

    Seidl, P. A.; Persaud, A.; Ghiorso, W.; Ji, Q.; Waldron, W. L.; Lal, A.; Vinayakumar, K. B.; Schenkel, T.

    2018-05-01

    Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

  8. Claims for fertility interventions: a systematic assessment of statements on UK fertility centre websites.

    PubMed

    Spencer, E A; Mahtani, K R; Goldacre, B; Heneghan, C

    2016-11-27

    Fertility services in the UK are offered by over 200 Human Fertilisation and Embryology Authority (HFEA)-registered NHS and private clinics. While in vitro fertilisation (IVF) and intracytoplasmic sperm injection (ICSI) form part of the National Institute for Health and Care Excellence (NICE) guidance, many further interventions are offered. We aimed to record claims of benefit for interventions offered by fertility centres via information on the centres' websites and record what evidence was cited for these claims. We obtained from HFEA a list of all UK centres providing fertility treatments and examined their websites. We listed fertility interventions offered in addition to standard IVF and ICSI and recorded statements about interventions that claimed or implied improvements in fertility in healthy women. We recorded which claims were quantified, and the evidence cited in support of the claims. Two reviewers extracted data from websites. We accessed websites from 21 December 2015 to 31 March 2016. We found 233 websites for HFEA-registered fertility treatment centres, of which 152 (65%) were excluded as duplicates or satellite centres, 2 were andrology clinics and 5 were unavailable or under construction websites. In total, 74 fertility centre websites, incorporating 1401 web pages, were examined for claims. We found 276 claims of benefit relating to 41 different fertility interventions made by 60 of the 74 centres (median 3 per website; range 0 to 10). Quantification was given for 79 (29%) of the claims. 16 published references were cited 21 times on 13 of the 74 websites. Many fertility centres in the UK offer a range of treatments in addition to standard IVF procedures, and for many of these interventions claims of benefit are made. In most cases, the claims are not quantified and evidence is not cited to support the claims. There is a need for more information on interventions to be made available by fertility centres, to support well-informed treatment

  9. The GNSS-based component for the new Indonesian tsunami early warning centre provided by GITEWS

    NASA Astrophysics Data System (ADS)

    Falck, C.; Ramatschi, M.; Bartsch, M.; Merx, A.; Hoeberechts, J.; Rothacher, M.

    2009-04-01

    sensors on land the processing system delivers deviations from their normal, mean coordinates. The deviations or so called displacements are indicators for land mass movements which can occur, e.g., due to strong earthquakes. The ground motion information is a valuable source for a fast understanding of an earthquake's mechanism with possible relevance for a potentially following tsunami. By this means the GNSS system supports the decision finding process whether most probably a tsunami has been generated or not. For buoy based GNSS data the processing (differential, with GNSS reference station on land) delivers coordinates as well. Only the vertical component is of interest as it corresponds to the instant sea level height. Deviations to the mean sea level height are an indicator for a possibly passing tsunami wave. The graphical user interface (GUI) of the GNSS system supports both, a quick view for all staff members at the warning centre (24h/7d shifts) and deeper analysis by GNSS experts. The GNSS GUI system is implemented as a web-based application and allows all views to be displayed on different screens at the same time, even at remote locations. This is part of the concept, as it can support the dialogue between warning centre staff on duty or on standby and sensor station maintenance staff. Acknowledgements The GITEWS project (German Indonesian Tsunami Early Warning System) is carried out by a large group of scientists and engineers from (GFZ) German Research Centre for Geosciences and its partners from the German Aerospace Centre (DLR), the Alfred Wegener Institute for Polar and Marine Research (AWI), the GKSS Research Centre, the Konsortium Deutsche Meeresforschung (KDM), the Leibniz Institute for Marine Sciences (IFM-GEOMAR), the United Nations University (UNU), the Federal Institute for Geosciences and Natural Resources (BGR), the German Agency for Technical Cooperation (GTZ) and other international partners. Most relevant partners in Indonesia with respect

  10. Towards a National Plan in Applied Education and Training.

    ERIC Educational Resources Information Center

    Adderley, John

    The National Computing Centre Limited (NCC), established by the British Government to extend and improve the use of computers in the United Kingdom, is a major force in computer science education. As part of the overall national plan, training course packages consisting of lecturer's materials, visual aids and student notes have been prepared for…

  11. A short history of the Science and Mathematics Education Centre at Curtin University

    NASA Astrophysics Data System (ADS)

    Treagust, David F.

    2011-09-01

    This article is presented in four parts. In the first part, I describe the foundation of the Science and Mathematics Education Centre (SMEC) at Curtin University. In the second part, I explain the development of SMEC's teaching and research capacity under its three directors. In the third section, I describe how federal government support of SMEC as a national Key Centre for Teaching and Research in School Science and Mathematics provided enhanced postgraduate study opportunities for science and mathematics teachers throughout Australia by offering degree programs through distance education and face-to-face contact, short courses, and seminars. At the same time, research and teaching capacity of the academic staff was enhanced through the internationalisation of the programs being offered. In the final section, I describe current and future developments at SMEC.

  12. Typology of birth centres in the Netherlands using the Rainbow model of integrated care: results of the Dutch Birth Centre Study.

    PubMed

    Boesveld, Inge C; Bruijnzeels, Marc A; Hitzert, Marit; Hermus, Marieke A A; van der Pal-de Bruin, Karin M; van den Akker-van Marle, M E; Steegers, Eric A P; Franx, Arie; de Vries, Raymond G; Wiegers, Therese A

    2017-06-21

    The goal of integrated care is to offer a continuum of care that crosses the boundaries of public health, primary, secondary, and tertiary care. Integrated care is increasingly promoted for people with complex needs and has also recently been promoted in maternity care systems to improve the quality of care. Especially when located near an obstetric unit, birth centres are considered to be ideal settings for the realization of integrated care. At present, however, we know very little about the degree of integration in these centres and we do not know if increased levels of integration improve the quality of the care delivered. The Dutch Birth Centre Study is designed to evaluate birth centres and their contribution to the Dutch maternity care system. The aim of this particular sub-study is to classify birth centres in clusters with similar characteristics based on integration profiles, to support the evaluation of birth centre care. This study is based on the Rainbow Model of Integrated Care. We used a survey followed by qualitative interviews in 23 birth centres in the Netherlands to determine which integration profiles can be distinguished and to describe their discriminating characteristics. Cluster analysis was used to classify the birth centres. Birth centres were classified into three clusters: 1)"Mono-disciplinary-oriented birth centres" (n = 10): which are mainly owned by primary care organizations and established as physical facilities to provide an alternative birthplace for low risk births; 2) "Multi-disciplinary-oriented birth centres" (n = 6): which are mainly multi-disciplinary oriented and can be regarded as facilities to give birth, with a focus on integrated birth care; 3) "Mixed Cluster of birth centres" (n = 7): which have a range of organizational forms that differentiate them from centres in the other clusters. We identified a recognizable classification, with similar characteristics between birth centres in the clusters. The results of

  13. Can Accelerators Accelerate Learning?

    NASA Astrophysics Data System (ADS)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-03-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ) [1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  14. Patient-centred outcomes research: perspectives of patient stakeholders.

    PubMed

    Chhatre, Sumedha; Gallo, Joseph J; Wittink, Marsha; Schwartz, J Sanford; Jayadevappa, Ravishankar

    2017-11-01

    To elicit patient stakeholders' experience and perspectives about patient-centred care. Qualitative. A large urban healthcare system. Four patient stakeholders who are prostate cancer survivors. Experience and perspectives of patient stakeholders regarding patient-centred care and treatment decisions. Our patient stakeholders represented a diverse socio-demographic group. The patient stakeholders identified engagement and dialogue with physicians as crucial elements of patient-centred care model. The degree of patient-centred care was observed to be dependent on the situations. High severity conditions warranted a higher level of patient involvement, compared to mild conditions. They agreed that patient-centred care should not mean that patients can demand inappropriate treatments. An important attribute of patient-centred outcomes research model is the involvement of stakeholders. However, we have limited knowledge about the experience of patient stakeholders in patient-centred outcomes research. Our study indicates that patient stakeholders offer a unique perspective as researchers and policy-makers aim to precisely define patient-centred research and care.

  15. Military Airlift: DOD Plans to Participate in Multi-National Program to Exchange Air Services with European Nations

    DTIC Science & Technology

    2013-10-30

    Air Transport, Air-to-Air Refueling and Other Exchange of Services ( ATARES ) program.1 ATARES is a European program through which member nations use a... ATARES is managed by the Movement Coordination Centre Europe (MCCE), a multi-national organization established in July 2007 to coordinate and optimize...of ATARES but is seeking to join the program. DOD is a member of MCCE and pays a fee for this membership; there is no additional fee to become a

  16. Undulator-Based Laser Wakefield Accelerator Electron Beam Energy Spread and Emittance Diagnostic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakeman, M. S.; University of Nevada Reno, Reno, NV 89557; Van Tilborg, J.

    The design and current status of experiments to couple the Tapered Hybrid Undulator (THUNDER) to the Lawrence Berkeley National Laboratory (LBNL) laser plasma accelerator (LPA) to measure electron beam energy spread and emittance are presented.

  17. The foundation of NCVD PCI Registry: the Malaysia's first multi-centre interventional cardiology project.

    PubMed

    Liew, H B; Rosli, M A; Wan Azman, W A; Robaayah, Z; Sim, K H

    2008-09-01

    The National Cardiovascular Database for Percutaneous Coronary Intervention (NCVD PCI) Registry is the first multicentre interventional cardiology project, involving the main cardiac centres in the country. The ultimate goal of NCVD PCI is to provide a contemporary appraisal of PCI in Malaysia. This article introduces the foundation, the aims, methodology, database collection and preliminary results of the first six-month database.

  18. Accelerations in Flight

    NASA Technical Reports Server (NTRS)

    Doolittle, J H

    1925-01-01

    This work on accelerometry was done at McCook Field for the purpose of continuing the work done by other investigators and obtaining the accelerations which occur when a high-speed pursuit airplane is subjected to the more common maneuvers. The accelerations obtained in suddenly pulling out of a dive with well-balanced elevators are shown to be within 3 or 4 per cent of the theoretically possible accelerations. The maximum acceleration which a pilot can withstand depends upon the length of time the acceleration is continued. It is shown that he experiences no difficulty under the instantaneous accelerations as high as 7.8 G., but when under accelerations in excess of 4.5 G., continued for several seconds, he quickly loses his faculties.

  19. Responses to a questionnaire on networking between OIE Reference Laboratories and OIE Collaborating Centres.

    PubMed

    Brückner, G K; Linnane, S; Diaz, F; Vallat, B

    2007-01-01

    Two separate questionnaires were distributed to 20 OIE Collaborating Centres and 160 OIE Reference Laboratories to assess the current status of networking and collaboration among OIE Reference Laboratories and between OIE Reference Laboratories and OIE Collaborating Centres. The questionnaire for the OIE Reference Laboratories contained 7 sections with questions on networking between laboratories, reporting of information, biosecurity quality control, and financing. Emphasis was placed in obtaining information on inter-laboratory relationships and exchange of expertise, training needs and sharing of data and information. The questionnaire for the OIE Collaborating Centres contained six sections with the emphasis on aspects related to awareness of services that can be provided, expertise that could be made available, sharing of information and the relationship with the national veterinary services of the countries concerned. The responses to the questionnaires were collated, categorised and statistically evaluated to allow for tentative inferences on the data provided. Valuable information emanated from the data identifying the current status of networking and indicating possible shortcomings that could be addressed to improve networking.

  20. High-Power Testing of 11.424-GHz Dielectric-Loaded Accelerating Structures

    NASA Astrophysics Data System (ADS)

    Gold, Steven; Gai, Wei

    2001-10-01

    Argonne National Laboratory has previously described the design, construction, and bench testing of an X-band traveling-wave accelerating structure loaded with a permittivity=20 dielectric (P. Zou et al., Rev. Sci. Instrum. 71, 2301, 2000.). We describe a new program to build a test accelerator using this structure. The accelerator will be powered by the high-power 11.424-GHz radiation from the magnicon facility at the Naval Research Laboratory ( O.A. Nezhevenko et al., Proc. PAC 2001, in press). The magnicon is expected to provide up to 30 MW from each of two WR-90 output waveguide arms in pulses of up to 1 microsecond duration, permitting tests up to a gradient of 40 MV/m. Still higher power pulses (100-500 MW) may be available at the output of an active pulse compressor driven by the magnicon ( A.L. Vikharev et al., Proc. 9th Workshop on Advanced Accelerator Concepts.).

  1. Shielding analyses for repetitive high energy pulsed power accelerators

    NASA Astrophysics Data System (ADS)

    Jow, H. N.; Rao, D. V.

    Sandia National Laboratories (SNL) designs, tests and operates a variety of accelerators that generate large amounts of high energy Bremsstrahlung radiation over an extended time. Typically, groups of similar accelerators are housed in a large building that is inaccessible to the general public. To facilitate independent operation of each accelerator, test cells are constructed around each accelerator to shield it from the radiation workers occupying surrounding test cells and work-areas. These test cells, about 9 ft. high, are constructed of high density concrete block walls that provide direct radiation shielding. Above the target areas (radiation sources), lead or steel plates are used to minimize skyshine radiation. Space, accessibility and cost considerations impose certain restrictions on the design of these test cells. SNL Health Physics division is tasked to evaluate the adequacy of each test cell design and compare resultant dose rates with the design criteria stated in DOE Order 5480.11. In response, SNL Health Physics has undertaken an intensive effort to assess existing radiation shielding codes and compare their predictions against measured dose rates. This paper provides a summary of the effort and its results.

  2. Lower Arm Muscle Activation during Indirect-Localized Vibration: The Influence of Skill Levels When Applying Different Acceleration Loads.

    PubMed

    Padulo, Johnny; Di Giminiani, Riccardo; Dello Iacono, Antonio; Zagatto, Alessandro M; Migliaccio, Gian M; Grgantov, Zoran; Ardigò, Luca P

    2016-01-01

    We investigated the electromyographic response to synchronous indirect-localized vibration interventions in international and national table tennis players. Twenty-six male table tennis players, in a standing position, underwent firstly an upper arms maximal voluntary contraction and thereafter two different 30-s vibration interventions in random order: high acceleration load (peak acceleration = 12.8 g, frequency = 40 Hz; peak-to-peak displacement = 4.0 mm), and low acceleration load (peak acceleration = 7.2 g, frequency = 30 Hz, peak-to-peak displacement = 4.0 mm). Surface electromyography root mean square from brachioradialis, extensor digitorum, flexor carpi radialis, and flexor digitorum superficialis recorded during the two vibration interventions was normalized to the maximal voluntary contraction recording. Normalized surface electromyography root mean square was higher in international table tennis players with respect to national ones in all the interactions between muscles and vibration conditions (P < 0.05), with the exception of flexor carpi radialis (at low acceleration load, P > 0.05). The difference in normalized surface electromyography root mean square between international table tennis players and national ones increased in all the muscles with high acceleration load (P < 0.05), with the exception of flexor digitorum superficialis (P > 0.05). The muscle activation during indirect-localized vibration seems to be both skill level and muscle dependent. These results can optimize the training intervention in table tennis players when applying indirect-localized vibration to lower arm muscles. Future investigations should discriminate between middle- and long-term adaptations in response to specific vibration loads.

  3. Lower Arm Muscle Activation during Indirect-Localized Vibration: The Influence of Skill Levels When Applying Different Acceleration Loads

    PubMed Central

    Padulo, Johnny; Di Giminiani, Riccardo; Dello Iacono, Antonio; Zagatto, Alessandro M.; Migliaccio, Gian M.; Grgantov, Zoran; Ardigò, Luca P.

    2016-01-01

    We investigated the electromyographic response to synchronous indirect-localized vibration interventions in international and national table tennis players. Twenty-six male table tennis players, in a standing position, underwent firstly an upper arms maximal voluntary contraction and thereafter two different 30-s vibration interventions in random order: high acceleration load (peak acceleration = 12.8 g, frequency = 40 Hz; peak-to-peak displacement = 4.0 mm), and low acceleration load (peak acceleration = 7.2 g, frequency = 30 Hz, peak-to-peak displacement = 4.0 mm). Surface electromyography root mean square from brachioradialis, extensor digitorum, flexor carpi radialis, and flexor digitorum superficialis recorded during the two vibration interventions was normalized to the maximal voluntary contraction recording. Normalized surface electromyography root mean square was higher in international table tennis players with respect to national ones in all the interactions between muscles and vibration conditions (P < 0.05), with the exception of flexor carpi radialis (at low acceleration load, P > 0.05). The difference in normalized surface electromyography root mean square between international table tennis players and national ones increased in all the muscles with high acceleration load (P < 0.05), with the exception of flexor digitorum superficialis (P > 0.05). The muscle activation during indirect-localized vibration seems to be both skill level and muscle dependent. These results can optimize the training intervention in table tennis players when applying indirect-localized vibration to lower arm muscles. Future investigations should discriminate between middle- and long-term adaptations in response to specific vibration loads. PMID:27378948

  4. Communicating astronomy by the Unizul Science Centre

    NASA Astrophysics Data System (ADS)

    Beesham, A.; Beesham, N.

    2015-03-01

    The University of Zululand, situated along the east coast of KwaZulu-Natal, has a thriving Science Centre (USC) situated in the developing port city of Richards Bay. Over 30 000 learners visit the centre annually, and it consists of an exhibition area, an auditorium, lecture areas and offices. The shows consist of interactive games, science shows, competitions, quizzes and matriculation workshops. Outreach activities take place through a mobile science centre for schools and communities that cannot visit the centre.

  5. Twin-Screw Extruder and Pellet Accelerator Integration Developments for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk

    The ITER pellet injection system consisting of a twinscrew frozen hydrogen isotope extruder, coupled to a combination solenoid actuated pellet cutter and pneumatic pellet accelerator, is under development at the Oak Ridge National Laboratory. A prototype extruder has been built to produce a continuous solid deuterium extrusion and will be integrated with a secondary section, where pellets are cut, chambered, and launched with a single-stage pneumatic accelerator into the plasma through a guide tube. This integrated pellet injection system is designed to provide 5 mm fueling pellets, injected at a rate up to 10 Hz, or 3 mm edge localizedmore » mode (ELM) triggering pellets, injected at higher rates up to 20 Hz. The pellet cutter, chamber mechanism, and the solenoid operated pneumatic valve for the accelerator are optimized to provide pellet velocities between 200-300 m/s to ensure high pellet survivability while traversing the inner wall fueling guide tubes, and outer wall ELMpacing guide tubes. This paper outlines the current twin-screwextruder design, pellet accelerator design, and the integrationrequired for both fueling and ELM pacing pellets.« less

  6. Observing two dark accelerators around the Galactic Centre with Fermi Large Area Telescope

    NASA Astrophysics Data System (ADS)

    Hui, C. Y.; Yeung, P. K. H.; Ng, C. W.; Lin, L. C. C.; Tam, P. H. T.; Cheng, K. S.; Kong, A. K. H.; Chernyshov, D. O.; Dogiel, V. A.

    2016-04-01

    We report the results from a detailed γ-ray investigation in the field of two `dark accelerators', HESS J1745-303 and HESS J1741-302, with 6.9 yr of data obtained by the Fermi Large Area Telescope. For HESS J1745-303, we found that its MeV-GeV emission is mainly originated from the `Region A' of the TeV feature. Its γ-ray spectrum can be modelled with a single power law with a photon index of Γ ˜ 2.5 from few hundreds MeV-TeV. Moreover, an elongated feature, which extends from `Region A' towards north-west for ˜1.3°, is discovered for the first time. The orientation of this feature is similar to that of a large-scale atomic/molecular gas distribution. For HESS J1741-302, our analysis does not yield any MeV-GeV counterpart for this unidentified TeV source. On the other hand, we have detected a new point source, Fermi J1740.1-3013, serendipitously. Its spectrum is apparently curved which resembles that of a γ-ray pulsar. This makes it possibly associated with PSR B1737-20 or PSR J1739-3023.

  7. Stochastic acceleration of electrons from multiple uncorrelated plasma waves

    NASA Astrophysics Data System (ADS)

    Gee, David; Michel, Pierre; Wurtele, Jonathan

    2017-10-01

    One-dimensional theory puts a strict limit on the maximum energy attainable by an electron trapped and accelerated by an electron plasma wave (EPW). However, experimental measurements of hot electron distributions accelerated by stimulated Raman scattering (SRS) in ICF experiments typically show a thermal distribution with temperatures of the order of the kinetic energy of the resonant EPW's (Thot mvp2 , where vp is the phase velocity of the EPW's driven by SRS) and no clear cutoff at high energies. In this project, we are investigating conditions under which electrons can be stochastically accelerated by multiple uncorrelated EPW's, such as those generated by incoherent laser speckles in large laser spots like the ones used on NIF ( mm-size), and reproduce distributions similar to those observed in experiments. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.

  8. The "magic" of tutorial centres in Hong Kong: An analysis of media marketing and pedagogy in a tutorial centre

    NASA Astrophysics Data System (ADS)

    Koh, Aaron

    2014-12-01

    Why do more than three-quarters of Hong Kong's senior secondary students flock to tutorial centres like moths to light? What is the "magic" that is driving the popularity of the tutorial centre enterprise? Indeed, looking at the ongoing boom of tutorial centres in Hong Kong (there are almost 1,000 of them), it is difficult not to ask these questions. This paper examines the phenomenon of tutorial centres in Hong Kong and seeks to understand what draws students to these centres. Combining theories of marketing semiotics and emotion studies, the author investigates the pivotal role of media marketing in generating the "magic" of tutorial centres, whose advertising strategy includes, for example, a display of billboard posters featuring stylishly-dressed "celebrity teachers". The author reviews some of the literature available on the subject of tutorial centres. In a case study approach, he then maps out the pedagogy he observed in an English tutorial class, seeking heuristic insights into the kind of teaching students in the study were looking for. He argues that part of the "magical" attraction of what are essentially "cram schools" is their formulaic pedagogy of teaching and reinforcing exam skills. Finally, the paper considers the social implications of the tutorial centre industry in terms of media marketing of education and unequal access to tutorial services.

  9. The Australian Prevention Partnership Centre: systems thinking to prevent lifestyle-related chronic illness.

    PubMed

    Wilson, Andrew; Wutzke, Sonia; Overs, Marge

    2014-11-28

    Chronic diseases are the major cause of death in Australia and the biggest contributor to premature death and disability. Although prevention of chronic disease can be effective and cost-effective, it has proven difficult to systematically implement interventions that target important lifestyle-related risk factors for chronic disease such as poor nutrition, physical inactivity and harmful alcohol use. Prevention efforts targeting these lifestyle-related risk factors have had mixed success due to issues around designing and implementing effective interventions that address the complexity of risk factors, and incorporating evidence and implementing interventions at a scale, duration, intensity and quality required to achieve population effects. There is increasing recognition that multilevel, multisector approaches are required for the effective and sustained prevention of complex chronic disease. The Australian Prevention Partnership Centre, one of two National Health and Medical Research Council Partnership Centres established in 2013, is researching and developing systems perspectives to prevent lifestyle-related chronic disease in Australia. The Centre's collaborative approach is providing opportunities for researchers to work with policy makers and practitioners to develop research questions, conduct research, and analyse, interpret and disseminate the findings. As such, it is the model of interaction that is being tested as much as the specific projects. With its funding partners, the Centre has developed plans for more than 30 projects. It has also established four capacity units that will improve the gathering, sharing and use of evidence to build a prevention system in Australia. The Centre is exploring new ways to advance prevention by bringing together researchers, policy makers and practitioners to determine the information and actions needed for an effective prevention system for Australia.

  10. National Minority Health Month Spotlight: Career Development

    Cancer.gov

    April is National Minority Health Month and in support of the 2016 theme, Accelerating Health Equity for the Nation, the NCI Center to Reduce Cancer Health Disparities (CRCHD) is highlighting how diversity training and career development opportunities are contributing to efforts to reduce the unequal burden of cancer in our society.

  11. What We Do | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Frederick National Laboratory is the only U.S. national lab wholly focused on research, technology, and collaboration in the biomedical sciences- working to discover, to innovate, and to improve human health. We accelerate progress against can

  12. Nonpoint Source: National Water Quality Initiative

    EPA Pesticide Factsheets

    National Water Quality Initiative (NWQI) is a collaborative between EPA and Natural Resource Conservation Service ( NRCS) that began in 2012. NWQI provides a means to accelerate voluntary, private lands conservation practices

  13. Global Inventory of Regional and National Qualifications Frameworks. Volume I: Thematic Chapters

    ERIC Educational Resources Information Center

    Deij, Arjen; Graham, Michael; Bjornavold, Jens; Grm, Slava Pevec; Villalba, Ernesto; Christensen, Hanne; Chakroun, Borhene; Daelman, Katrien; Carlsen, Arne; Singh, Madhu

    2015-01-01

    The "Global Inventory of Regional and National Qualifications Frameworks," the result of collaborative work between the European Training Foundation (ETF), the European Centre for the Development of Vocational Training (Cedefop), UNESCO [United Nations Educational, Scientific and Cultural Organization] and UIL [UNESCO Institute for…

  14. Indian Institute of Technology Bombay and Tata Memorial Centre Join the International Efforts in Clinical Proteogenomics Cancer Research | Office of Cancer Clinical Proteomics Research

    Cancer.gov

    The National Cancer Institute’s (NCI) Office of Cancer Clinical Proteomics Research, part of the National Institutes of Health, along with the Indian Institute of Technology Bombay (IITB) and Tata Memorial Centre (TMC) have signed a Memorandum of Understanding (MOU) on clinical proteogenomics cancer research. The MOU between NCI, IITB, and Tata Memorial Centre represents the thirtieth and thirty-first institutions and the twelfth country to join the International Cancer Proteogenome Consortium (ICPC). The purpose of the MOU is to facilitate scientific and programmatic collaborations between NCI, IITB, and TMC in basic and clinical proteogenomic studies leading to patient care and public dissemination and information sharing to the research community.

  15. Compact Plasma Accelerator

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2004-01-01

    A plasma accelerator has been conceived for both material-processing and spacecraft-propulsion applications. This accelerator generates and accelerates ions within a very small volume. Because of its compactness, this accelerator could be nearly ideal for primary or station-keeping propulsion for spacecraft having masses between 1 and 20 kg. Because this accelerator is designed to generate beams of ions having energies between 50 and 200 eV, it could also be used for surface modification or activation of thin films.

  16. The German national registry for primary immunodeficiencies (PID)

    PubMed Central

    Gathmann, B; Goldacker, S; Klima, M; Belohradsky, B H; Notheis, G; Ehl, S; Ritterbusch, H; Baumann, U; Meyer-Bahlburg, A; Witte, T; Schmidt, R; Borte, M; Borte, S; Linde, R; Schubert, R; Bienemann, K; Laws, H-J; Dueckers, G; Roesler, J; Rothoeft, T; Krüger, R; Scharbatke, E C; Masjosthusmann, K; Wasmuth, J-C; Moser, O; Kaiser, P; Groß-Wieltsch, U; Classen, C F; Horneff, G; Reiser, V; Binder, N; El-Helou, S M; Klein, C; Grimbacher, B; Kindle, G

    2013-01-01

    In 2009, a federally funded clinical and research consortium (PID–NET, http://www.pid-net.org) established the first national registry for primary immunodeficiencies (PID) in Germany. The registry contains clinical and genetic information on PID patients and is set up within the framework of the existing European Database for Primary Immunodeficiencies, run by the European Society for Primary Immunodeficiencies. Following the example of other national registries, a central data entry clerk has been employed to support data entry at the participating centres. Regulations for ethics approvals have presented a major challenge for participation of individual centres and have led to a delay in data entry in some cases. Data on 630 patients, entered into the European registry between 2004 and 2009, were incorporated into the national registry. From April 2009 to March 2012, the number of contributing centres increased from seven to 21 and 738 additional patients were reported, leading to a total number of 1368 patients, of whom 1232 were alive. The age distribution of living patients differs significantly by gender, with twice as many males than females among children, but 15% more women than men in the age group 30 years and older. The diagnostic delay between onset of symptoms and diagnosis has decreased for some PID over the past 20 years, but remains particularly high at a median of 4 years in common variable immunodeficiency (CVID), the most prevalent PID. PMID:23607573

  17. Microelectromechanical acceleration-sensing apparatus

    DOEpatents

    Lee, Robb M [Albuquerque, NM; Shul, Randy J [Albuquerque, NM; Polosky, Marc A [Albuquerque, NM; Hoke, Darren A [Albuquerque, NM; Vernon, George E [Rio Rancho, NM

    2006-12-12

    An acceleration-sensing apparatus is disclosed which includes a moveable shuttle (i.e. a suspended mass) and a latch for capturing and holding the shuttle when an acceleration event is sensed above a predetermined threshold level. The acceleration-sensing apparatus provides a switch closure upon sensing the acceleration event and remains latched in place thereafter. Examples of the acceleration-sensing apparatus are provided which are responsive to an acceleration component in a single direction (i.e. a single-sided device) or to two oppositely-directed acceleration components (i.e. a dual-sided device). A two-stage acceleration-sensing apparatus is also disclosed which can sense two acceleration events separated in time. The acceleration-sensing apparatus of the present invention has applications, for example, in an automotive airbag deployment system.

  18. Incorporation of National Universities in Japan

    ERIC Educational Resources Information Center

    Oba, Jun

    2007-01-01

    In April 2004, Japanese national universities were incorporated and became much more autonomous from the government in their operations. Their managerial structure was realigned--placing the president at the centre of the decision-making process, and with the participation of external persons--to be more responsive to the changing needs of…

  19. SHORT ACCELERATION TIMES FROM SUPERDIFFUSIVE SHOCK ACCELERATION IN THE HELIOSPHERE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perri, S.; Zimbardo, G., E-mail: silvia.perri@fis.unical.it

    2015-12-10

    The analysis of time profiles of particles accelerated at interplanetary shocks allows particle transport properties to be inferred. The frequently observed power-law decay upstream, indeed, implies a superdiffusive particle transport when the level of magnetic field variance does not change as the time interval from the shock front increases. In this context, a superdiffusive shock acceleration (SSA) theory has been developed, allowing us to make predictions of the acceleration times. In this work we estimate for a number of interplanetary shocks, including the solar wind termination shock, the acceleration times for energetic protons in the framework of SSA and wemore » compare the results with the acceleration times predicted by standard diffusive shock acceleration. The acceleration times due to SSA are found to be much shorter than in the classical model, and also shorter than the interplanetary shock lifetimes. This decrease of the acceleration times is due to the scale-free nature of the particle displacements in the framework of superdiffusion. Indeed, very long displacements are possible, increasing the probability for particles far from the front of the shock to return, and short displacements have a high probability of occurrence, increasing the chances for particles close to the front to cross the shock many times.« less

  20. Accelerator-based techniques for the support of senior-level undergraduate physics laboratories

    NASA Astrophysics Data System (ADS)

    Williams, J. R.; Clark, J. C.; Isaacs-Smith, T.

    2001-07-01

    Approximately three years ago, Auburn University replaced its aging Dynamitron accelerator with a new 2MV tandem machine (Pelletron) manufactured by the National Electrostatics Corporation (NEC). This new machine is maintained and operated for the University by Physics Department personnel, and the accelerator supports a wide variety of materials modification/analysis studies. Computer software is available that allows the NEC Pelletron to be operated from a remote location, and an Internet link has been established between the Accelerator Laboratory and the Upper-Level Undergraduate Teaching Laboratory in the Physics Department. Additional software supplied by Canberra Industries has also been used to create a second Internet link that allows live-time data acquisition in the Teaching Laboratory. Our senior-level undergraduates and first-year graduate students perform a number of experiments related to radiation detection and measurement as well as several standard accelerator-based experiments that have been added recently. These laboratory exercises will be described, and the procedures used to establish the Internet links between our Teaching Laboratory and the Accelerator Laboratory will be discussed.

  1. MABE multibeam accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasti, D.E.; Ramirez, J.J.; Coleman, P.D.

    1985-01-01

    The Megamp Accelerator and Beam Experiment (MABE) was the technology development testbed for the multiple beam, linear induction accelerator approach for Hermes III, a new 20 MeV, 0.8 MA, 40 ns accelerator being developed at Sandia for gamma-ray simulation. Experimental studies of a high-current, single-beam accelerator (8 MeV, 80 kA), and a nine-beam injector (1.4 MeV, 25 kA/beam) have been completed, and experiments on a nine-beam linear induction accelerator are in progress. A two-beam linear induction accelerator is designed and will be built as a gamma-ray simulator to be used in parallel with Hermes III. The MABE pulsed power systemmore » and accelerator for the multiple beam experiments is described. Results from these experiments and the two-beam design are discussed. 11 refs., 6 figs.« less

  2. A new approach to characterize very-low-level radioactive waste produced at hadron accelerators.

    PubMed

    Zaffora, Biagio; Magistris, Matteo; Chevalier, Jean-Pierre; Luccioni, Catherine; Saporta, Gilbert; Ulrici, Luisa

    2017-04-01

    Radioactive waste is produced as a consequence of preventive and corrective maintenance during the operation of high-energy particle accelerators or associated dismantling campaigns. Their radiological characterization must be performed to ensure an appropriate disposal in the disposal facilities. The radiological characterization of waste includes the establishment of the list of produced radionuclides, called "radionuclide inventory", and the estimation of their activity. The present paper describes the process adopted at CERN to characterize very-low-level radioactive waste with a focus on activated metals. The characterization method consists of measuring and estimating the activity of produced radionuclides either by experimental methods or statistical and numerical approaches. We adapted the so-called Scaling Factor (SF) and Correlation Factor (CF) techniques to the needs of hadron accelerators, and applied them to very-low-level metallic waste produced at CERN. For each type of metal we calculated the radionuclide inventory and identified the radionuclides that most contribute to hazard factors. The methodology proposed is of general validity, can be extended to other activated materials and can be used for the characterization of waste produced in particle accelerators and research centres, where the activation mechanisms are comparable to the ones occurring at CERN. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Probing electron acceleration and x-ray emission in laser-plasma accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thaury, C.; Ta Phuoc, K.; Corde, S.

    2013-06-15

    While laser-plasma accelerators have demonstrated a strong potential in the acceleration of electrons up to giga-electronvolt energies, few experimental tools for studying the acceleration physics have been developed. In this paper, we demonstrate a method for probing the acceleration process. A second laser beam, propagating perpendicular to the main beam, is focused on the gas jet few nanosecond before the main beam creates the accelerating plasma wave. This second beam is intense enough to ionize the gas and form a density depletion, which will locally inhibit the acceleration. The position of the density depletion is scanned along the interaction lengthmore » to probe the electron injection and acceleration, and the betatron X-ray emission. To illustrate the potential of the method, the variation of the injection position with the plasma density is studied.« less

  4. Major chemical incidents--a response, the role of the Consultant in Communicable Disease Control and the case of need for a national surveillance-resource centre.

    PubMed

    Ayres, P J

    1995-06-01

    The aim of this study is to discuss the adequacy of current arrangements for dealing with major chemical incidents through the offices of the Consultant in Communicable Disease Control (CCDC). This paper describes the public health response to an explosion at a chemical works which was followed by illnesses of unknown aetiology in emergency service workers and other people. An outline of the circumstances as they presented themselves and a description of the lessons learned from the management of this disaster are presented alongside an overview of the prevailing infrastructure of advice, support and training available to CsCDC. Key issues relevant to these areas are discussed. A total of 181 potential cases were notified to the investigating team, of whom 115 had an illness possibly associated with the explosion. Of these, 93 suffered a gastrointestinal illness and 68 had so-called 'toxic' symptoms (eye, skin and bronchopulmonary irritation). Forty-six people had both sets of symptoms at the same time. Current arrangements dictate that public health physicians have a role in incidents such as this, whether they seek such a position or not. The specialty would do well to consider developing formal disaster training schemes for those likely to have to manage major incidents (usually the CCDC), and would benefit from the setting up of a chemical-environmental incident surveillance-resource centre. Such a centre should have a remit for teaching and training, information support, incident recording, coordination of expert resources, and liaison between interested bodies both nationally and internationally.

  5. Metrics for Success in the Preservation of Scientific Data at the STFC Centre for Environmental Data Archival (CEDA).

    NASA Astrophysics Data System (ADS)

    Lawrence, B.; Pepler, S.

    2009-04-01

    CEDA (http://www.ceda.ac.uk) hosts three main data centres: the British Atmospheric Data Centre (http://badc.nerc.ac.uk), the NERC Earth Observation Data Centre (http://neodc.nerc.ac.uk), and the Intergovernmental Panel for Climate Change Dedicated Data Centre (http://ipcc-data.org) as well as components of many national and international projects. CEDA recieves both core funding (from the UK Natural Environment Research Council) and per project funding (from a variety of sources). However, all funders require metrics assessing success. In the case of preservation it is hard to measure success - usage alone is not enough, since next year someone may use currently unused data if it is well preserved, and so it is the act of preservation which in this case marks success. Even where data is accessed, it is not necessarily used. Hence at CEDA we have three key focii in our approach to metrics: measuring direct website access, benchmarking procedures against best practice, and hopefully soon, recording data citation. In this presentation we cover how we are addressing each of these three areas.

  6. Perspectives on recycling centres and future developments.

    PubMed

    Engkvist, I-L; Eklund, J; Krook, J; Björkman, M; Sundin, E

    2016-11-01

    The overall aim of this paper is to draw combined, all-embracing conclusions based on a long-term multidisciplinary research programme on recycling centres in Sweden, focussing on working conditions, environment and system performance. A second aim is to give recommendations for their development of new and existing recycling centres and to discuss implications for the future design and organisation. Several opportunities for improvement of recycling centres were identified, such as design, layout, ease with which users could sort their waste, the work environment, conflicting needs and goals within the industry, and industrialisation. Combining all results from the research, which consisted of different disciplinary aspects, made it possible to analyse and elucidate their interrelations. Waste sorting quality was recognized as the most prominent improvement field in the recycling centre system. The research identified the importance of involving stakeholders with different perspectives when planning a recycling centre in order to get functionality and high performance. Practical proposals of how to plan and build recycling centres are given in a detailed checklist. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Overview | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Frederick National Laboratoryis a founding member of theAccelerating Therapeutics for Opportunities in Medicine (ATOM)Consortium,a public-private partnership with themission oftransforming drug discovery by

  8. The status and road map of Turkish Accelerator Center (TAC)

    NASA Astrophysics Data System (ADS)

    Yavaş, Ö.

    2012-02-01

    Turkish Accelerator Center (TAC) project is supported by the State Planning Organization (SPO) of Turkey and coordinated by Ankara University. After having completed the Feasibility Report (FR) in 2000 and the Conceptual Design Report (CDR) in 2005, third phase of the project started in 2006 as an inter-universities project including ten Turkish Universities with the support of SPO. Third phase of the project has two main scientific goals: to prepare the Technical Design Report (TDR) of TAC and to establish an Infrared Free Electron Laser (IR FEL) facility, named as Turkish Accelerator and Radiation Laboratory at Ankara (TARLA) as a first step. The facility is planned to be completed in 2015 and will be based on 15-40 MeV superconducting linac. In this paper, main aims, national and regional importance, main parts main parameters, status and road map of Turkish Accelerator Center will be presented.

  9. Patient-centred care: a review for rehabilitative audiologists.

    PubMed

    Grenness, Caitlin; Hickson, Louise; Laplante-Lévesque, Ariane; Davidson, Bronwyn

    2014-02-01

    This discussion paper aims to synthesise the literature on patient-centred care from a range of health professions and to relate this to the field of rehabilitative audiology. Through review of the literature, this paper addresses five questions: What is patient-centred care? How is patient-centred care measured? What are the outcomes of patient-centred care? What are the factors contributing to patient-centred care? What are the implications for audiological rehabilitation? Literature review and synthesis. Publications were identified by structured searches in PubMed, Cinahl, Web of Knowledge, and PsychInfo, and by inspecting the reference lists of relevant articles. Few publications from within the audiology profession address this topic and consequently a review and synthesis of literature from other areas of health were used to answer the proposed questions. This paper concludes that patient-centred care is in line with the aims and scope of practice for audiological rehabilitation. However, there is emerging evidence that we still need to inform the conceptualisation of patient-centred audiological rehabilitation. A definition of patient-centred audiological rehabilitation is needed to facilitate studies into the nature and outcomes of it in audiological rehabilitation practice.

  10. Acceleration in U.S. Mean Sea Level? A New Insight using Improved Tools

    NASA Astrophysics Data System (ADS)

    Watson, Phil J.

    2016-08-01

    The detection of acceleration in mean sea level around the data-rich margins of the United States has been a keen endeavour of sea-level researchers following the seminal work of Bruce Douglas in 1992. Over the past decade, such investigations have taken on greater prominence given mean sea level remains a key proxy by which to measure a changing climate system. The physics-based climate projection models are forecasting that the current global average rate of mean sea-level rise (≈3 mm/y) might climb to rates in the range of 10020 mm/y by 2100. Most research in this area has centred on reconciling current rates of rise with the significant accelerations required to meet the forecast projections of climate models. The analysis in this paper is based on a recently developed analytical package titled "msltrend," specifically designed to enhance estimates of trend, real-time velocity and acceleration in the relative mean sea-level signal derived from long annual average ocean-water-level time series. Key findings are that at the 95% confidence level, no consistent or substantial evidence (yet) exists that recent rates of rise are higher or abnormal in the context of the historical records available for the United States, nor does any evidence exist that geocentric rates of rise are above the global average. It is likely that a further 20 years of data will identify whether recent increases east of Galveston and along the east coast are evidence of the onset of climate change induced acceleration.

  11. Jerome Lewis Duggan: A Nuclear Physicist and a Well-Known, Six-Decade Accelerator Application Conference (CAARI) Organizer

    NASA Astrophysics Data System (ADS)

    Del McDaniel, Floyd; Doyle, Barney L.

    Jerry Duggan was an experimental MeV-accelerator-based nuclear and atomic physicist who, over the past few decades, played a key role in the important transition of this field from basic to applied physics. His fascination for and application of particle accelerators spanned almost 60 years, and led to important discoveries in the following fields: accelerator-based analysis (accelerator mass spectrometry, ion beam techniques, nuclear-based analysis, nuclear microprobes, neutron techniques); accelerator facilities, stewardship, and technology development; accelerator applications (industrial, medical, security and defense, and teaching with accelerators); applied research with accelerators (advanced synthesis and modification, radiation effects, nanosciences and technology); physics research (atomic and molecular physics, and nuclear physics); and many other areas and applications. Here we describe Jerry’s physics education at the University of North Texas (B. S. and M. S.) and Louisiana State University (Ph.D.). We also discuss his research at UNT, LSU, and Oak Ridge National Laboratory, his involvement with the industrial aspects of accelerators, and his impact on many graduate students, colleagues at UNT and other universities, national laboratories, and industry and acquaintances around the world. Along the way, we found it hard not to also talk about his love of family, sports, fishing, and other recreational activities. While these were significant accomplishments in his life, Jerry will be most remembered for his insight in starting and his industry in maintaining and growing what became one of the most diverse accelerator conferences in the world — the International Conference on the Application of Accelerators in Research and Industry, or what we all know as CAARI. Through this conference, which he ran almost single-handed for decades, Jerry came to know, and became well known by, literally thousands of atomic and nuclear physicists, accelerator

  12. Jerome Lewis Duggan: A Nuclear Physicist and a Well-Known, Six-Decade Accelerator Application Conference (CAARI) Organizer

    NASA Astrophysics Data System (ADS)

    Del McDaniel, Floyd; Doyle, Barney L.

    Jerry Duggan was an experimental MeV-accelerator-based nuclear and atomic physicist who, over the past few decades, played a key role in the important transition of this field from basic to applied physics. His fascination for and application of particle accelerators spanned almost 60 years, and led to important discoveries in the following fields: accelerator-based analysis (accelerator mass spectrometry, ion beam techniques, nuclear-based analysis, nuclear microprobes, neutron techniques); accelerator facilities, stewardship, and technology development; accelerator applications (industrial, medical, security and defense, and teaching with accelerators); applied research with accelerators (advanced synthesis and modification, radiation effects, nanosciences and technology); physics research (atomic and molecular physics, and nuclear physics); and many other areas and applications. Here we describe Jerry's physics education at the University of North Texas (B. S. and M. S.) and Louisiana State University (Ph.D.). We also discuss his research at UNT, LSU, and Oak Ridge National Laboratory, his involvement with the industrial aspects of accelerators, and his impact on many graduate students, colleagues at UNT and other universities, national laboratories, and industry and acquaintances around the world. Along the way, we found it hard not to also talk about his love of family, sports, fishing, and other recreational activities. While these were significant accomplishments in his life, Jerry will be most remembered for his insight in starting and his industry in maintaining and growing what became one of the most diverse accelerator conferences in the world — the International Conference on the Application of Accelerators in Research and Industry, or what we all know as CAARI. Through this conference, which he ran almost single-handed for decades, Jerry came to know, and became well known by, literally thousands of atomic and nuclear physicists, accelerator

  13. Neutron dose per fluence and weighting factors for use at high energy accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cossairt, J.Donald; Vaziri, Kamran; /Fermilab

    2008-07-01

    In June 2007, the United States Department of Energy incorporated revised values of neutron weighting factors into its occupational radiation protection Regulation 10 CFR Part 835 as part of updating its radiation dosimetry system. This has led to a reassessment of neutron radiation fields at high energy proton accelerators such as those at the Fermi National Accelerator Laboratory (Fermilab). Values of dose per fluence factors appropriate for accelerator radiation fields calculated elsewhere are collated and radiation weighting factors compared. The results of this revision to the dosimetric system are applied to americium-beryllium neutron energy spectra commonly used for instrument calibrations.more » A set of typical accelerator neutron energy spectra previously measured at Fermilab are reassessed in light of the new dosimetry system. The implications of this revision are found to be of moderate significance.« less

  14. Social-emotional characteristics of gifted accelerated and non-accelerated students in the Netherlands.

    PubMed

    Hoogeveen, Lianne; van Hell, Janet G; Verhoeven, Ludo

    2012-12-01

    In the studies of acceleration conducted so far a multidimensional perspective has largely been neglected. No attempt has been made to relate social-emotional characteristics of accelerated versus non-accelerated students in perspective of environmental factors. In this study, social-emotional characteristics of accelerated gifted students in the Netherlands were examined in relation to personal and environmental factors. Self-concept and social contacts of accelerated (n = 148) and non-accelerated (n = 55) gifted students, aged 4 to 27 (M = 11.22, SD = 4.27) were measured. Self-concept and social contacts of accelerated and non-accelerated gifted students were measured using a questionnaire and a diary, and parents of these students evaluated their behavioural characteristics. Gender and birth order were studied as personal factors and grade, classroom, teachers' gender, teaching experience, and the quality of parent-school contact as environmental factors. The results showed minimal differences in the social-emotional characteristics of accelerated and non-accelerated gifted students. The few differences we found favoured the accelerated students. We also found that multiple grade skipping does not have negative effects on social-emotional characteristics, and that long-term effects of acceleration tend to be positive. As regards the possible modulation of personal and environmental factors, we merely found an impact of such factors in the non-accelerated group. The results of this study strongly suggest that social-emotional characteristics of accelerated gifted students and non-accelerated gifted students are largely similar. These results thus do not support worries expressed by teachers about the acceleration of gifted students. Our findings parallel the outcomes of earlier studies in the United States and Germany in that we observed that acceleration does not harm gifted students, not even in the case of multiple grade skipping. On the contrary, there is a

  15. India Solar Resource Data: Enhanced Data for Accelerated Deployment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    Identifying potential locations for solar photovoltaic (PV) and concentrating solar power (CSP) projects requires an understanding of the underlying solar resource. Under a bilateral partnership between the United States and India - the U.S.-India Energy Dialogue - the National Renewable Energy Laboratory has updated Indian solar data and maps using data provided by the Ministry of New and Renewable Energy (MNRE) and the National Institute for Solar Energy (NISE). This fact sheet overviews the updated maps and data, which help identify high-quality solar energy projects. This can help accelerate the deployment of solar energy in India.

  16. Review of CERN Data Centre Infrastructure

    NASA Astrophysics Data System (ADS)

    Andrade, P.; Bell, T.; van Eldik, J.; McCance, G.; Panzer-Steindel, B.; Coelho dos Santos, M.; Traylen and, S.; Schwickerath, U.

    2012-12-01

    The CERN Data Centre is reviewing strategies for optimizing the use of the existing infrastructure and expanding to a new data centre by studying how other large sites are being operated. Over the past six months, CERN has been investigating modern and widely-used tools and procedures used for virtualisation, clouds and fabric management in order to reduce operational effort, increase agility and support unattended remote data centres. This paper gives the details on the project's motivations, current status and areas for future investigation.

  17. WHO Collaborating Centre for Acquired Immunodeficiency Syndrome for the Eastern Mediterranean Regional Office, Faculty of Medicine, Kuwait University, Kuwait.

    PubMed

    Altawalah, Haya; Al-Nakib, Widad

    2014-01-01

    In the early 1980s, the World Health Organization (WHO) designated the Virology Unit of the Faculty of Medicine, Health Sciences Centre, Kuwait University, Kuwait, a collaborating centre for AIDS for the Eastern Mediterranean Regional Office (EMRO), recognizing it to be in compliance with WHO guidelines. In this centre, research integral to the efforts of WHO to combat AIDS is conducted. In addition to annual workshops and symposia, the centre is constantly updating and renewing its facilities and capabilities in keeping with current and latest advances in virology. As an example of the activities of the centre, the HIV-1 RNA viral load in plasma samples of HIV-1 patients is determined by real-time PCR using the AmpliPrep TaqMan HIV-1 test v2.0. HIV-1 drug resistance is determined by sequencing the reverse transcriptase and protease regions on the HIV-1 pol gene, using the TRUGENE HIV-1 Genotyping Assay on the OpenGene® DNA Sequencing System. HIV-1 subtypes are determined by sequencing the reverse transcriptase and protease regions on the HIV-1 pol gene using the genotyping assays described above. A fundamental program of Kuwait's WHO AIDS collaboration centre is the national project on the surveillance of drug resistance in human deficiency virus in Kuwait, which illustrates how the centre and its activities in Kuwait can serve the EMRO region of WHO. © 2014 S. Karger AG, Basel.

  18. The International Linear Collider Technical Design Report - Volume 3.I: Accelerator \\& in the Technical Design Phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adolphsen, Chris

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  19. On the Existence of Step-To-Step Breakpoint Transitions in Accelerated Sprinting

    PubMed Central

    McGhie, David; Danielsen, Jørgen; Sandbakk, Øyvind; Haugen, Thomas

    2016-01-01

    Accelerated running is characterised by a continuous change of kinematics from one step to the next. It has been argued that breakpoints in the step-to-step transitions may occur, and that these breakpoints are an essential characteristic of dynamics during accelerated running. We examined this notion by comparing a continuous exponential curve fit (indicating continuity, i.e., smooth transitions) with linear piecewise fitting (indicating breakpoint). We recorded the kinematics of 24 well trained sprinters during a 25 m sprint run with start from competition starting blocks. Kinematic data were collected for 24 anatomical landmarks in 3D, and the location of centre of mass (CoM) was calculated from this data set. The step-to-step development of seven variables (four related to CoM position, and ground contact time, aerial time and step length) were analysed by curve fitting. In most individual sprints (in total, 41 sprints were successfully recorded) no breakpoints were identified for the variables investigated. However, for the mean results (i.e., the mean curve for all athletes) breakpoints were identified for the development of vertical CoM position, angle of acceleration and distance between support surface and CoM. It must be noted that for these variables the exponential fit showed high correlations (r2>0.99). No relationship was found between the occurrences of breakpoints for different variables as investigated using odds ratios (Mantel-Haenszel Chi-square statistic). It is concluded that although breakpoints regularly appear during accelerated running, these are not the rule and thereby unlikely a fundamental characteristic, but more likely an expression of imperfection of performance. PMID:27467387

  20. 78 FR 24154 - Notice of Availability of a National Animal Health Laboratory Network Reorganization Concept Paper

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-24

    ...] Notice of Availability of a National Animal Health Laboratory Network Reorganization Concept Paper AGENCY... Network (NAHLN) for public review and comment. The NAHLN is a nationally coordinated network and... Coordinator, National Animal Health Laboratory Network, Veterinary Services, APHIS, 2140 Centre Avenue...

  1. Toward Successful Implementation of Prefabricated Deck Panels to Accelerate the Bridge Construction Process

    DOT National Transportation Integrated Search

    2016-08-01

    The development of accelerated bridge construction (ABC) techniques and connection details has become a national research focus. With the aging of the interstate system and many bridges on key routes requiring extensive rehabilitation or replacement,...

  2. The "Magic" of Tutorial Centres in Hong Kong: An Analysis of Media Marketing and Pedagogy in a Tutorial Centre

    ERIC Educational Resources Information Center

    Koh, Aaron

    2014-01-01

    Why do more than three-quarters of Hong Kong's senior secondary students flock to tutorial centres like moths to light? What is the "magic" that is driving the popularity of the tutorial centre enterprise? Indeed, looking at the ongoing boom of tutorial centres in Hong Kong (there are almost 1,000 of them), it is difficult not to ask…

  3. Comparison of planned menus and centre characteristics with foods and beverages served in New York City child-care centres.

    PubMed

    Breck, Andrew; Dixon, L Beth; Kettel Khan, Laura

    2016-10-01

    The present study evaluated the extent to which child-care centre menus prepared in advance correspond with food and beverage items served to children. The authors identified centre and staff characteristics that were associated with matches between menus and what was served. Menus were collected from ninety-five centres in New York City (NYC). Direct observation of foods and beverages served to children were conducted during 524 meal and snack times at these centres between April and June 2010, as part of a larger study designed to determine compliance of child-care centres with city health department regulations for nutrition. Child-care centres were located in low-income neighbourhoods in NYC. Overall, 87 % of the foods and beverages listed on the menus or allowed as substitutions were served. Menu items matched with foods and beverages served for all major food groups by >60 %. Sweets and water had lower match percentages (40 and 32 %, respectively), but water was served 68 % of the time when it was not listed on the menu. The staff person making the food and purchasing decisions predicted the match between the planned or substituted items on the menus and the foods and beverages served. In the present study, child-care centre menus included most foods and beverages served to children. Menus planned in advance have potential to be used to inform parents about which child-care centre to send their child or what foods and beverages their enrolled children will be offered throughout the day.

  4. Comparison of planned menus and centre characteristics with foods and beverages served in New York City child-care centres

    PubMed Central

    Breck, Andrew; Dixon, L Beth; Khan, Laura Kettel

    2016-01-01

    Objective The present study evaluated the extent to which child-care centre menus prepared in advance correspond with food and beverage items served to children. The authors identified centre and staff characteristics that were associated with matches between menus and what was served. Design Menus were collected from ninety-five centres in New York City (NYC). Direct observation of foods and beverages served to children were conducted during 524 meal and snack times at these centres between April and June 2010, as part of a larger study designed to determine compliance of child-care centres with city health department regulations for nutrition. Setting Child-care centres were located in low-income neighbourhoods in NYC. Results Overall, 87% of the foods and beverages listed on the menus or allowed as substitutions were served. Menu items matched with foods and beverages served for all major food groups by > 60%. Sweets and water had lower match percentages (40 and 32%, respectively), but water was served 68% of the time when it was not listed on the menu. The staff person making the food and purchasing decisions predicted the match between the planned or substituted items on the menus and the foods and beverages served. Conclusions In the present study, child-care centre menus included most foods and beverages served to children. Menus planned in advance have potential to be used to inform parents about which child-care centre to send their child or what foods and beverages their enrolled children will be offered throughout the day. PMID:27280341

  5. Impact of the galactic acceleration on the terrestrial reference frame and the scale factor in VLBI

    NASA Astrophysics Data System (ADS)

    Krásná, Hana; Titov, Oleg

    2017-04-01

    The relative motion of the solar system barycentre around the galactic centre can also be described as an acceleration of the solar system directed towards the centre of the Galaxy. So far, this effect has been omitted in the a priori modelling of the Very Long Baseline Interferometry (VLBI) observable. Therefore, it results in a systematic dipole proper motion (Secular Aberration Drift, SAD) of extragalactic radio sources building the celestial reference frame with a theoretical maximum magnitude of 5-7 microarcsec/year. In this work, we present our estimation of the SAD vector obtained within a global adjustment of the VLBI measurements (1979.0 - 2016.5) using the software VieVS. We focus on the influence of the observed radio sources with the maximum SAD effect on the terrestrial reference frame. We show that the scale factor from the VLBI measurements estimated for each source individually discloses a clear systematic aligned with the direction to the Galactic centre-anticentre. Therefore, the radio sources located near Galactic anticentre may cause a strong systematic effect, especially, in early VLBI years. For instance, radio source 0552+398 causes a difference up to 1 mm in the estimated baseline length. Furthermore, we discuss the scale factor estimated for each radio source after removal of the SAD systematic.

  6. Accelerated Leach Testing of GLASS: ALTGLASS Version 3.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trivelpiece, Cory L.; Jantzen, Carol M.; Crawford, Charles L.

    The Accelerated Leach Testing of GLASS (ALTGLASS) database is a collection of data from short- and long-term product consistency tests (PCT, ASTM C1285 A and B) on high level waste (HLW) as well as low activity waste (LAW) glasses. The database provides both U.S. and international researchers with an archive of experimental data for the purpose of studying, modeling, or validating existing models of nuclear waste glass corrosion. The ALTGLASS database is maintained and updated by researchers at the Savannah River National Laboratory (SRNL). This newest version, ALTGLASS Version 3.0, has been updated with an additional 503 rows of datamore » representing PCT results from corrosion experiments conducted in the United States by the Savannah River National Laboratory, Pacific Northwest National Laboratory, Argonne National Laboratory, and the Vitreous State Laboratory (SRNL, PNNL, ANL, VSL, respectively) as well as the National Nuclear Laboratory (NNL) in the United Kingdom.« less

  7. International Energy Agency's Heat Pump Centre (IEA-HPC) Annual National Team Working Group Meeting

    NASA Astrophysics Data System (ADS)

    Broders, M. A.

    1992-09-01

    The traveler, serving as Delegate from the United States Advanced Heat Pump National Team, participated in the activities of the fourth IEA-HPC National Team Working Group meeting. Highlights of this meeting included review and discussion of 1992 IEA-HPC activities and accomplishments, introduction of the Switzerland National Team, and development of the 1993 IEA-HPC work program. The traveler also gave a formal presentation about the Development and Activities of the IEA Advanced Heat Pump U.S. National Team.

  8. The illusion of client-centred practice.

    PubMed

    Gupta, Jyothi; Taff, Steven D

    2015-07-01

    A critical analysis of occupational therapy practice in the corporate health care culture in a free market economy was undertaken to demonstrate incongruence with the profession's philosophical basis and espoused commitment to client-centred practice. The current practice of occupational therapy in the reimbursement-driven practice arena in the United States is incongruent with the profession's espoused philosophy and values of client-centred practice. Occupational therapy differentiates itself from medicine's expert model aimed at curing disease and remediating impairment, by its claim to client-centred practice focused on restoring health through occupational enablement. Practice focused on impairment and function is at odds with the profession's core tenet, occupation, and minimizes the lasting impact of interventions on health and well-being. The profession cannot unleash the therapeutic power of human occupation in settings where body systems and body functions are not occupation-ready at the requisite levels for occupational participation. Client-centred practice is best embodied by occupation-focused interventions in the natural environment of everyday living. Providing services that are impairment-focused in unfamiliar settings is not a good fit for client-centred practice, which is the unique, authentic, and sustainable orientation for the profession.

  9. Mental health in Sexual Assault Referral Centres: A survey of forensic physicians.

    PubMed

    Brooker, Charlie; Paul, Sheila; Sirdifield, Coral

    2018-05-22

    A national survey of Forensic Physicians (FPs) working in Sexual Assault Referral Centres was undertaken. The survey was advertised in the weekly bulletin sent out by the Faculty of Forensic and Legal Medicine. Response was relatively low (n = 45). It is estimated that this figures represents about 12% of the workforce. The aim of the survey was to investigate FPs experience of accessing mental health pathways out of a SARC for complainants of all ages. The results concurred with a previous survey of SARC clinical managers with mental health services proving unresponsive. Informed co-commissioning between NHS England and Clinical Commissioning groups can only improve if aspects of complainant's mental health are routinely assessed within SARCs using structured outcome measures. Structured outcomes should be integrated into NHS England's Sexual Assault Referral Centres Indicators of Performance (SARCIP). Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  10. Accelerator Production of Isotopes for Medical Use

    NASA Astrophysics Data System (ADS)

    Lapi, Suzanne

    2014-03-01

    The increase in use of radioisotopes for medical imaging and therapy has led to the development of novel routes of isotope production. For example, the production and purification of longer-lived position emitting radiometals has been explored to allow for nuclear imaging agents based on peptides, antibodies and nanoparticles. These isotopes (64Cu, 89Zr, 86Y) are typically produced via irradiation of solid targets on smaller medical cyclotrons at dedicated facilities. Recently, isotope harvesting from heavy ion accelerator facilities has also been suggested. The Facility for Rare Isotope Beams (FRIB) will be a new national user facility for nuclear science to be completed in 2020. Radioisotopes could be produced by dedicated runs by primary users or may be collected synergistically from the water in cooling-loops for the primary beam dump that cycle the water at flow rates in excess of hundreds of gallons per minute. A liquid water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory (NSCL) was designed and constructed as the initial step in proof-of-principle experiments to harvest useful radioisotopes in this manner. This talk will provide an overview of isotope production using both dedicated machines and harvesting from larger accelerators typically used for nuclear physics. Funding from Department of Energy under DESC0007352 and DESC0006862.

  11. The obtaining relative position of lunar centre masses and centre of the figure in selenocentric catalogues

    NASA Astrophysics Data System (ADS)

    Nefedjev, Yu. A.; Valeev, S. G.; Rizvanov, N. G.; Mikeev, R. R.; Varaksina, N. Yu.

    2010-05-01

    The relative position of lunar center masses relative to center of the figure in Kazan and Kiev selenocentric catalogues was customized. The expansions by spherical harmonics N=5 degree and order of the lunar function h(λ, β) with using the package ASNI USTU were executed. Module of the expansion of the local area to surfaces to full sphere was used. The parameters of cosmic missions are given for comparison (SAI; Bills, Ferrari). The normalized coefficients from expansions for eight sources hypsometric information are obtained: - Clementine (N=40), - Kazan (N=5), - Kiev (N=5), - SAI (N=10; Chuikova (1975)), - Bills, Ferrari, - Каguуа (Selena, Japan mission), - ULCN (The Uuified Lunaz Control Network 2005). The displacements of the lunar centre figure relative to lunar centre of the masses were defined from equations (Chuikova (1975)). The results of the obtaining relative position of the lunar centre masses and centre of the figure in Kazan selenocentric catalogue give good agreement with modern cosmic mission data.

  12. Enabling cost-effective high-current burst-mode operation in superconducting accelerators

    DOE PAGES

    Sheffield, Richard L.

    2015-06-01

    Superconducting (SC) accelerators are very efficient for CW or long-pulse operation, and normal conducting (NC) accelerators are cost effective for short-pulse operation. The addition of a short NC linac section to a SC linac can correct for the energy droop that occurs when pulsed high-current operation is required that exceeds the capability of the klystrons to replenish the cavity RF fields due to the long field fill-times of SC structures, or a requirement to support a broad range of beam currents results in variable beam loading. This paper describes the implementation of this technique to enable microseconds of high beam-current,more » 90 mA or more, in a 12 GeV SC long-pulse accelerator designed for the MaRIE 42-keV XFEL proposed for Los Alamos National Laboratory.« less

  13. A Foreign Model of Teacher Education and Its Local Appropriation: The English Teachers' Centres in Spain

    ERIC Educational Resources Information Center

    Groves, Tamar

    2015-01-01

    This article explores the implementation of the English model of teachers' centres in the context of 1980s Spain. Originally it was a top-down plan initiated by a national government. However, from the very beginning its fate was dependent on a bottom-up educational project carried out by pedagogical social movements. The first part of the article…

  14. A new model of collaborative research: experiences from one of Australia's NHMRC Partnership Centres for Better Health.

    PubMed

    Wutzke, Sonia; Redman, Sally; Bauman, Adrian; Hawe, Penelope; Shiell, Alan; Thackway, Sarah; Wilson, Andrew

    2017-02-15

    There is often a disconnection between the creation of evidence and its use in policy and practice. Cross-sectoral, multidisciplinary partnership research, founded on shared governance and coproduction, is considered to be one of the most effective means of overcoming this research-policy-practice disconnect. Similar to a number of funding bodies internationally, Australia's National Health and Medical Research Council has introduced Partnership Centres for Better Health: a scheme explicitly designed to encourage coproduced partnership research. In this paper, we describe our experiences of The Australian Prevention Partnership Centre, established in June 2013 to explore the systems, strategies and structures that inform decisions about how to prevent lifestyle-related chronic disease. We present our view on how the Partnership Centre model is working in practice. We comment on the unique features of the Partnership Centre funding model, how these features enable ways of working that are different from both investigator-initiated and commissioned research, and how these ways of working can result in unique outcomes that would otherwise not have been possible. Although not without challenges, the Partnership Centre approach addresses a major gap in the Australian research environment, whereby large-scale, research-policy-practice partnerships are established with sufficient time, resources and flexibility to deliver highly innovative, timely and accessible research that is of use to policy and practice.

  15. Direct longitudinal laser acceleration of electrons in free space

    NASA Astrophysics Data System (ADS)

    Carbajo, Sergio; Nanni, Emilio A.; Wong, Liang Jie; Moriena, Gustavo; Keathley, Phillip D.; Laurent, Guillaume; Miller, R. J. Dwayne; Kärtner, Franz X.

    2016-02-01

    Compact laser-driven accelerators are pursued heavily worldwide because they make novel methods and tools invented at national laboratories widely accessible in science, health, security, and technology [V. Malka et al., Principles and applications of compact laser-plasma accelerators, Nat. Phys. 4, 447 (2008)]. Current leading laser-based accelerator technologies [S. P. D. Mangles et al., Monoenergetic beams of relativistic electrons from intense laser-plasma interactions, Nature (London) 431, 535 (2004); T. Toncian et al., Ultrafast laser-driven microlens to focus and energy-select mega-electron volt protons, Science 312, 410 (2006); S. Tokita et al. Single-shot ultrafast electron diffraction with a laser-accelerated sub-MeV electron pulse, Appl. Phys. Lett. 95, 111911 (2009)] rely on a medium to assist the light to particle energy transfer. The medium imposes material limitations or may introduce inhomogeneous fields [J. R. Dwyer et al., Femtosecond electron diffraction: "Making the molecular movie,", Phil. Trans. R. Soc. A 364, 741 (2006)]. The advent of few cycle ultraintense radially polarized lasers [S. Carbajo et al., Efficient generation of ultraintense few-cycle radially polarized laser pulses, Opt. Lett. 39, 2487 (2014)] has ushered in a novel accelerator concept [L. J. Wong and F. X. Kärtner, Direct acceleration of an electron in infinite vacuum by a pulsed radially polarized laser beam, Opt. Express 18, 25035 (2010); F. Pierre-Louis et al. Direct-field electron acceleration with ultrafast radially polarized laser beams: Scaling laws and optimization, J. Phys. B 43, 025401 (2010); Y. I. Salamin, Electron acceleration from rest in vacuum by an axicon Gaussian laser beam, Phys. Rev. A 73, 043402 (2006); C. Varin and M. Piché, Relativistic attosecond electron pulses from a free-space laser-acceleration scheme, Phys. Rev. E 74, 045602 (2006); A. Sell and F. X. Kärtner, Attosecond electron bunches accelerated and compressed by radially polarized laser

  16. The Imperial College Thermophysical Properties Data Centre

    NASA Astrophysics Data System (ADS)

    Angus, S.; Cole, W. A.; Craven, R.; de Reuck, K. M.; Trengove, R. D.; Wakeham, W. A.

    1986-07-01

    The IUPAC Thermodynamic Tables Project Centre in London has at its disposal considerable expertise on the production and utilization of high-accuracy equations of state which represent the thermodynamic properties of substances. For some years they have been content to propagate this information by the traditional method of book production, but the increasing use of the computer in industry for process design has shown that an additional method was needed. The setting up of the IUPAC Transport Properties Project Centre, also at Imperial College, whose products would also be in demand by industry, afforded the occasion for a new look at the problem. The solution has been to set up the Imperial College Thermophysical Properties Data Centre, which embraces the two IUPAC Project Centres, and for it to establish a link with the existing Physical Properties Data Service of the Institution of Chemical Engineers, thus providing for the dissemination of the available information without involving the Centres in problems such as those of marketing and advertising. This paper outlines the activities of the Centres and discusses the problems in bringing their products to the attention of industry in suitable form.

  17. Investigating the job satisfaction of healthcare providers at primary healthcare centres in Lebanon: A national cross-sectional study.

    PubMed

    Alameddine, Mohamad; Baroud, Maysa; Kharroubi, Samer; Hamadeh, Randa; Ammar, Walid; Shoaib, Hikma; Khodr, Hiba

    2017-11-01

    Low job satisfaction is linked to higher staff turnover and intensified shortages in healthcare providers (HCP). This study investigates the level of, and factors associated with, HCP job satisfaction in the national primary healthcare (PHC) network in Lebanon. The study adopts a cross-sectional design to survey HCP at 99 PHC centres distributed across the country between October 2013 and May 2014. The study questionnaire consisted of four sections: socio-demographics/professional background, employment characteristics, level of job satisfaction (Measure of Job Satisfaction scale) and level of professional burnout (Maslach Burnout Inventory-HSS scale). A total of 1,000 providers completed the questionnaire (75.8% response rate). Bivariate and multivariate regression analyses were used to identify factors significantly associated with job satisfaction. Findings of the study highlight an overall mean job satisfaction score of 3.59 (SD 0.54) indicating that HCP are partially satisfied. Upon further examination, HCP were least satisfied with pay, training and job prospects. Gender, age, career plans, salary, exposure to violence, and level of burnout were significantly associated with the overall level of job satisfaction which was also associated with increased likelihood to quit. Overall, the study highlights how compensation, development and protection of PHC HCP can influence their job satisfaction. Recommendations include the necessity of developing a nationally representative committee, led by the Ministry of Public Health, to examine the policies and remuneration scales within the PHC sector and suggest mechanisms to bridge the pay differential with other sectors. The effective engagement of key stakeholders with the development, organisation and evaluation of professional development programmes offered to HCP in the PHC sector remains crucial. Concerned stakeholders should assess and formulate initiatives and programmes that enrich the physical, psychological

  18. Semiconductor acceleration sensor

    NASA Astrophysics Data System (ADS)

    Ueyanagi, Katsumichi; Kobayashi, Mitsuo; Goto, Tomoaki

    1996-09-01

    This paper reports a practical semiconductor acceleration sensor especially suited for automotive air bag systems. The acceleration sensor includes four beams arranged in a swastika structure. Two piezoresistors are formed on each beam. These eight piezoresistors constitute a Wheatstone bridge. The swastika structure of the sensing elements, an upper glass plate and a lower glass plate exhibit the squeeze film effect which enhances air dumping, by which the constituent silicon is prevented from breakdown. The present acceleration sensor has the following features. The acceleration force component perpendicular to the sensing direction can be cancelled. The cross-axis sensitivity is less than 3 percent. And, the erroneous offset caused by the differences between the thermal expansion coefficients of the constituent materials can be canceled. The high aspect ratio configuration realized by plasma etching facilitates reducing the dimensions and improving the sensitivity of the acceleration sensor. The present acceleration sensor is 3.9 mm by 3.9 mm in area and 1.2 mm in thickness. The present acceleration sensor can measure from -50 to +50 G with sensitivity of 0.275 mV/G and with non-linearity of less than 1 percent. The acceleration sensor withstands shock of 3000 G.

  19. The Dutch Birth Centre Study: study design of a programmatic evaluation of the effect of birth centre care in the Netherlands.

    PubMed

    Hermus, Marieke A A; Wiegers, Therese A; Hitzert, Marit F; Boesveld, Inge C; van den Akker-van Marle, M Elske; Akkermans, Henk A; Bruijnzeels, Marc A; Franx, Arie; de Graaf, Johanna P; Rijnders, Marlies E B; Steegers, Eric A P; van der Pal-de Bruin, Karin M

    2015-07-16

    Birth centres are regarded as settings where women with uncomplicated pregnancies can give birth, assisted by a midwife and a maternity care assistant. In case of (threatening) complications referral to a maternity unit of a hospital is necessary. In the last decade up to 20 different birth centres have been instituted in the Netherlands. This increase in birth centres is attributed to various reasons such as a safe and easy accessible place of birth, organizational efficiency in integration of care and direct access to obstetric hospital care if needed, and better use of maternity care assistance. Birth centres are assumed to offer increased integration and quality of care and thus to contribute to better perinatal and maternal outcomes. So far there is no evidence for this assumption as no previous studies of birth centres have been carried out in the Netherlands. The aims are 1) Identification of birth centres and measuring integration of organization and care 2) Measuring the quality of birth centre care 3) Effects of introducing a birth centre on regional quality and provision of care 4) Cost-effectiveness analysis 5) In depth longitudinal analysis of the organization and processes in birth centres. Different qualitative and quantitative methods will be used in the different sub studies. The design is a multi-centre, multi-method study, including surveys, interviews, observations, and analysis of registration data and documents. The results of this study will enable users of maternity care, professionals, policy makers and health care financers to make an informed choice about the kind of birth location that is appropriate for their needs and wishes.

  20. Development of a Dielectric-Loaded Accelerator Test Facility Based on an X-Band Magnicon Amplifier

    NASA Astrophysics Data System (ADS)

    Gold, S. H.; Kinkead, A. K.; Gai, W.; Power, J. G.; Konecny, R.; Jing, C.; Tantawi, S. G.; Nantista, C. D.; Hu, Y.; Du, X.; Tang, C.; Lin, Y.; Bruce, R. W.; Bruce, R. L.; Fliflet, A. W.; Lewis, D.

    2006-01-01

    The Naval Research Laboratory (NRL) and Argonne National Laboratory (ANL), in collaboration with the Stanford Linear Accelerator Center (SLAC), are developing a dielectric-loaded accelerator (DLA) test facility powered by the 11.424-GHz magnicon amplifier that was developed jointly by NRL and Omega-P, Inc. Thus far, DLA structures developed by ANL have been tested at the NRL Magnicon Facility without injected electrons, including tests of alumina and magnesium calcium titanate structures at gradients up to ˜8 MV/m. The next step is to inject electrons in order to build a compact DLA test accelerator. The Accelerator Laboratory of Tsinghua University in Beijing, China has developed a 5-MeV electron injector for the accelerator, and SLAC is developing a means to combine the two magnicon output arms, and to drive the injector and an accelerator section with separate control of the power ratio and relative phase. Also, RWBruce Associates, working with NRL, is developing a means to join ceramic tubes to produce long accelerating sections using a microwave brazing process. The installation and commissioning of the first dielectric-loaded test accelerator, including injector, DLA structure, and spectrometer, should take place within the next year.

  1. Aligning the magnetic field of a linear induction accelerator with a low-energy electron beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, J.C.; Deadrick, F.J.; Kallman, J.S.

    1989-03-10

    The Experimental Test Accelerator II (ETA-II) linear induction accelerator at Lawrence Livermore National Laboratory uses a solenoid magnet in each acceleration cell to focus and transport an electron beam over the length of the accelerator. To control growth of the corkscrew mode the magnetic field must be precisely aligned over the full length of the accelerate. Concentric with each solenoid magnet is sine/cosmic-wound correction coil to steer the beam and correct field errors. A low-energy electron probe traces the central flux line through the accelerator referenced to a mechanical axis that is defined by a copropagating laser beam. Correction coilsmore » are activated to force the central flux line to cross the mechanical axis at the end of each acceleration cell. The ratios of correction coil currents determined by the low-energy electron probe are then kept fixed to correct for field errors during normal operation with an accelerated beam. We describe the construction of the low-energy electron probe and report the results of experiments we conducted to measure magnetic alignment with and without the correction coils activated. 5 refs., 3 figs.« less

  2. Women's questions about medicines in pregnancy - An analysis of calls to an Australian national medicines call centre.

    PubMed

    Pijpers, Eva L; Kreijkamp-Kaspers, Sanne; McGuire, Treasure M; Deckx, Laura; Brodribb, Wendy; van Driel, Mieke L

    2017-06-01

    For many medicines, safe use during pregnancy is not established and adherence is often poor due to safety concerns. Therefore, it is important to identify consumers' medicines information needs during pregnancy. A retrospective, mixed methods analysis was conducted on eight years of pregnancy-related calls to an Australian national medicines call centre. The call profile of pregnancy and non-pregnancy-related questions were compared. Medicines involved in pregnancy calls were categorised by class (Anatomical Therapeutic Chemical (ATC)3 level), and Therapeutic Goods Administration pregnancy category. Questions in these calls were also themed by pregnancy stage. We identified 4573 pregnancy-related and 118 547 non-pregnancy-related calls. The caller profile for pregnancy-related calls was female (93.7%), asking for herself (83.0%), and while 70.1% of questions involved one medicine, 9.6% involved three or more medicines. Pregnancy enquiries were prompted more often by conflicting information, inadequate information or desire for a second opinion. For 1166 calls, where the stage of pregnancy was available, most questions concerned safety. Medication classified as 'safe' during pregnancy accounted for 34% of these questions. After antidepressants, most calls were made about over-the-counter (OTC) medicines (paracetamol, dexchlorpheniramine, codeine). Safe treatment for everyday conditions was of increasing concern as the pregnancy progressed. Pregnant women are concerned about the safety of medication use in pregnancy and a significant proportion overestimate risk. Psychotropic medication and fertility are strong drivers to seek information during preconception. Everyday illnesses and self-medication with OTC medication are a common concern throughout pregnancy, even though many medicines are safe to use. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  3. Signature energetic analysis of accelerate electron beam after first acceleration station by accelerating stand of Joint Institute for Nuclear Research

    NASA Astrophysics Data System (ADS)

    Sledneva, A. S.; Kobets, V. V.

    2017-06-01

    The linear electron accelerator based on the LINAC - 800 accelerator imported from the Netherland is created at Joint Institute for Nuclear Research in the framework of the project on creation of the Testbed with an electron beam of a linear accelerator with an energy up to 250 MV. Currently two accelerator stations with a 60 MV energy of a beam are put in operation and the work is to put the beam through accelerating section of the third accelerator station. The electron beam with an energy of 23 MeV is used for testing the crystals (BaF2, CsI (native), and LYSO) in order to explore the opportunity to use them in particle detectors in experiments: Muon g-2, Mu2e, Comet, whose preparation requires a detailed study of the detectors properties such as their irradiation by the accelerator beams.

  4. FERMILAB ACCELERATOR R&D PROGRAM TOWARDS INTENSITY FRONTIER ACCELERATORS : STATUS AND PROGRESS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiltsev, Vladimir

    2016-11-15

    The 2014 P5 report indicated the accelerator-based neutrino and rare decay physics research as a centrepiece of the US domestic HEP program at Fermilab. Operation, upgrade and development of the accelerators for the near- term and longer-term particle physics program at the Intensity Frontier face formidable challenges. Here we discuss key elements of the accelerator physics and technology R&D program toward future multi-MW proton accelerators and present its status and progress. INTENSITY FRONTIER ACCELERATORS

  5. The nitrogen-vacancy colour centre in diamond

    NASA Astrophysics Data System (ADS)

    Doherty, Marcus W.; Manson, Neil B.; Delaney, Paul; Jelezko, Fedor; Wrachtrup, Jörg; Hollenberg, Lloyd C. L.

    2013-07-01

    The nitrogen-vacancy (NV) colour centre in diamond is an important physical system for emergent quantum technologies, including quantum metrology, information processing and communications, as well as for various nanotechnologies, such as biological and sub-diffraction limit imaging, and for tests of entanglement in quantum mechanics. Given this array of existing and potential applications and the almost 50 years of NV research, one would expect that the physics of the centre is well understood, however, the study of the NV centre has proved challenging, with many early assertions now believed false and many remaining issues yet to be resolved. This review represents the first time that the key empirical and ab initio results have been extracted from the extensive NV literature and assembled into one consistent picture of the current understanding of the centre. As a result, the key unresolved issues concerning the NV centre are identified and the possible avenues for their resolution are examined.

  6. Student-Centred and Teacher-Centred Learning Environment in Pre-Vocational Secondary Education: Psychological Needs, and Motivation

    ERIC Educational Resources Information Center

    Smit, Karin; de Brabander, Cornelis J.; Martens, Rob L.

    2014-01-01

    In this study the perception of psychological needs and motivation in a student-centred and a teacher-centred learning environment are compared, using Self Determination Theory as a framework. The self-report Intrinsic Motivation Inventory was completed by 230 students (mean age 16.1 years) in pre-vocational secondary education. School records on…

  7. NOTE: Blood irradiation with accelerator produced electron beams

    NASA Astrophysics Data System (ADS)

    Butson, M. J.; Cheung, T.; Yu, P. K. N.; Stokes, M. J.

    2000-11-01

    Blood and blood products are irradiated with gamma rays to reduce the risk of graft versus host disease (GVHD). A simple technique using electron beams produced by a medical linear accelerator has been studied to evaluate irradiation of blood and blood products. Variations in applied doses for a single field 20 MeV electron beam are measured in a phantom study. Doses have been verified with ionization chambers and commercial diode detectors. Results show that the blood product volume can be given a relatively homogeneous dose to within 6% using 20 MeV electrons without the need to rotate the blood bags or the beam entry point. The irradiation process takes approximately 6.5 minutes for 30 Gy applied dose to complete as opposed to 12 minutes for a dual field x-ray field irradiation at our centre. Electron beams can be used to satisfactorily irradiate blood and blood products in a minimal amount of time.

  8. Barriers to ART adherence & follow ups among patients attending ART centres in Maharashtra, India.

    PubMed

    Joglekar, N; Paranjape, R; Jain, R; Rahane, G; Potdar, R; Reddy, K S; Sahay, S

    2011-12-01

    Adherence to ART is a patient specific issue influenced by a variety of situations that a patient may encounter, especially in resource-limited settings. A study was conducted to understand factors and influencers of adherence to ART and their follow ups among patients attending ART centres in Maharashtra, India. Between January and March 2009, barriers to ART adherence among 32 patients at three selected ART centres functioning under national ART roll-out programme in Maharashtra, India, were studied using qualitative methods. Consenting patients were interviewed to assess barriers to ART adherence. Constant comparison method was used to identify grounded codes. Patients reported multiple barriers to ART adherence and follow up as (i) Financial barriers where the contributing factors were unemployment, economic dependency, and debt, (ii) social norm of attending family rituals, and fulfilling social obligations emerged as socio-cultural barriers, (iii) patients' belief, attitude and behaviour towards medication and self-perceived stigma were the reasons for sub-optimal adherence, and (iv) long waiting period, doctor-patient relationship and less time devoted in counselling at the center contributed to missed visits. Mainstreaming ART can facilitate access and address 'missed doses' due to travel and migration. A 'morning' and 'evening' ART centre/s hours may reduce work absenteeism and help in time management. Proactive 'adherence probing' and probing on internalized stigma might optimize adherence. Adherence probing to prevent transitioning to suboptimal adherence among patients stable on ART is recommended.

  9. The Centre of High-Performance Scientific Computing, Geoverbund, ABC/J - Geosciences enabled by HPSC

    NASA Astrophysics Data System (ADS)

    Kollet, Stefan; Görgen, Klaus; Vereecken, Harry; Gasper, Fabian; Hendricks-Franssen, Harrie-Jan; Keune, Jessica; Kulkarni, Ketan; Kurtz, Wolfgang; Sharples, Wendy; Shrestha, Prabhakar; Simmer, Clemens; Sulis, Mauro; Vanderborght, Jan

    2016-04-01

    The Centre of High-Performance Scientific Computing (HPSC TerrSys) was founded 2011 to establish a centre of competence in high-performance scientific computing in terrestrial systems and the geosciences enabling fundamental and applied geoscientific research in the Geoverbund ABC/J (geoscientfic research alliance of the Universities of Aachen, Cologne, Bonn and the Research Centre Jülich, Germany). The specific goals of HPSC TerrSys are to achieve relevance at the national and international level in (i) the development and application of HPSC technologies in the geoscientific community; (ii) student education; (iii) HPSC services and support also to the wider geoscientific community; and in (iv) the industry and public sectors via e.g., useful applications and data products. A key feature of HPSC TerrSys is the Simulation Laboratory Terrestrial Systems, which is located at the Jülich Supercomputing Centre (JSC) and provides extensive capabilities with respect to porting, profiling, tuning and performance monitoring of geoscientific software in JSC's supercomputing environment. We will present a summary of success stories of HPSC applications including integrated terrestrial model development, parallel profiling and its application from watersheds to the continent; massively parallel data assimilation using physics-based models and ensemble methods; quasi-operational terrestrial water and energy monitoring; and convection permitting climate simulations over Europe. The success stories stress the need for a formalized education of students in the application of HPSC technologies in future.

  10. Pulse Front Tilt and Laser Plasma Acceleration

    NASA Astrophysics Data System (ADS)

    Mittelberger, Daniel; Thévenet, Maxence; Nakamura, Kei; Lehe, Remi; Gonsalves, Anthony; Benedetti, Carlo; Leemans, Wim

    2017-10-01

    Pulse front tilt (PFT) is potentially present in any CPA laser system, but its effects may be overlooked because spatiotemporal pulse characterization is considerably more involved than measuring only spatial or temporal profile. PFT is particularly important for laser plasma accelerators (LPA) because it influences electron beam injection and steering. In this work, experimental results from the BELLA Center will be presented that demonstrate the effect of optical grating misalignment and optical compression, resulting in PFT, on accelerator performance. Theoretical models of laser and electron beam steering will be introduced based on particle-in-cell simulations showing distortion of the plasma wake. Theoretical predictions will be compared with experiments and complimentary simulations, and tolerances on PFT and optical compressor alignment will be developed as a function of LPA performance requirements. This work was supported by the Office of High Energy Physics, Office of Science, US Department of Energy under Contract DE-AC02-05CH11231 and the National Science Foundation under Grant PHY-1415596.

  11. Precise charge measurement for laser plasma accelerators

    NASA Astrophysics Data System (ADS)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Sokollik, Thomas; Shiraishi, Satomi; van Tilborg, Jeroen; Smith, Alan; Rodgers, Dave; Donahue, Rick; Byrne, Warren; Leemans, Wim

    2011-10-01

    A comprehensive study of charge diagnostics was conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. Using an integrating current transformer as a calibration reference, the sensitivity of the Lanex Fast was found to decrease by 1% per 100 MeV increase of the energy. By using electron beams from LPA, cross calibrations of the charge were carried out with an integrating current transformer, scintillating screen (Lanex from Kodak), and activation based measurement. The diagnostics agreed within ~8%, showing that they all can provide accurate charge measurements for LPAs provided necessary cares. Work supported by the Office of Science, Office of High Energy Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

  12. Corkscrew Motion of an Electron Beam due to Coherent Variations in Accelerating Potentials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekdahl, Carl August

    2016-09-13

    Corkscrew motion results from the interaction of fluctuations of beam electron energy with accidental magnetic dipoles caused by misalignment of the beam transport solenoids. Corkscrew is a serious concern for high-current linear induction accelerators (LIA). A simple scaling law for corkscrew amplitude derived from a theory based on a constant-energy beam coasting through a uniform magnetic field has often been used to assess LIA vulnerability to this effect. We use a beam dynamics code to verify that this scaling also holds for an accelerated beam in a non-uniform magnetic field, as in a real accelerator. Results of simulations with thismore » code are strikingly similar to measurements on one of the LIAs at Los Alamos National Laboratory.« less

  13. Deformation-induced structural transition in body-centred cubic molybdenum

    PubMed Central

    Wang, S. J.; Wang, H.; Du, K.; Zhang, W.; Sui, M. L.; Mao, S. X.

    2014-01-01

    Molybdenum is a refractory metal that is stable in a body-centred cubic structure at all temperatures before melting. Plastic deformation via structural transitions has never been reported for pure molybdenum, while transformation coupled with plasticity is well known for many alloys and ceramics. Here we demonstrate a structural transformation accompanied by shear deformation from an original <001>-oriented body-centred cubic structure to a <110>-oriented face-centred cubic lattice, captured at crack tips during the straining of molybdenum inside a transmission electron microscope at room temperature. The face-centred cubic domains then revert into <111>-oriented body-centred cubic domains, equivalent to a lattice rotation of 54.7°, and ~15.4% tensile strain is reached. The face-centred cubic structure appears to be a well-defined metastable state, as evidenced by scanning transmission electron microscopy and nanodiffraction, the Nishiyama–Wassermann and Kurdjumov–Sachs relationships between the face-centred cubic and body-centred cubic structures and molecular dynamics simulations. Our findings reveal a deformation mechanism for elemental metals under high-stress deformation conditions. PMID:24603655

  14. Centre-Based Child Care Quality in Urban Australia

    ERIC Educational Resources Information Center

    Ishimine, Karin; Wilson, Rachel

    2009-01-01

    This study investigates the quality of childcare centres in urban Australian communities designated according to different bands of Centre Location Demographics (CLD). Childcare centres were assessed using the Early Childhood Environment Rating Scale- Revised Edition (ECERS-R) and the Early Childhood Environment Rating Scale-Extension (ECERS-E).…

  15. Accelerators for society: succession of European infrastructural projects: CARE, EuCARD, TIARA, EuCARD2

    NASA Astrophysics Data System (ADS)

    Romaniuk, Ryszard S.

    2013-10-01

    Accelerator science and technology is one of a key enablers of the developments in the particle physic, photon physics and also applications in medicine and industry. The paper presents a digest of the research results in the domain of accelerator science and technology in Europe, shown during the realization of CARE (Coordinated Accelerator R&D), EuCARD (European Coordination of Accelerator R&D) and during the national annual review meeting of the TIARA - Test Infrastructure of European Research Area in Accelerator R&D. The European projects on accelerator technology started in 2003 with CARE. TIARA is an European Collaboration of Accelerator Technology, which by running research projects, technical, networks and infrastructural has a duty to integrate the research and technical communities and infrastructures in the global scale of Europe. The Collaboration gathers all research centers with large accelerator infrastructures. Other ones, like universities, are affiliated as associate members. TIARA-PP (preparatory phase) is an European infrastructural project run by this Consortium and realized inside EU-FP7. The paper presents a general overview of CARE, EuCARD and especially TIARA activities, with an introduction containing a portrait of contemporary accelerator technology and a digest of its applications in modern society. CARE, EuCARD and TIARA activities integrated the European accelerator community in a very effective way. These projects are expected very much to be continued.

  16. Accelerated test design

    NASA Technical Reports Server (NTRS)

    Mcdermott, P. P.

    1980-01-01

    The design of an accelerated life test program for electric batteries is discussed. A number of observations and suggestions on the procedures and objectives for conducting an accelerated life test program are presented. Equations based on nonlinear regression analysis for predicting the accelerated life test parameters are discussed.

  17. Student-Centred Learning (SCL): Roles Changed?

    ERIC Educational Resources Information Center

    Onurkan Aliusta, Gülen; Özer, Bekir

    2017-01-01

    This paper addresses the espoused and enacted practices of high school teachers with regard to student-centred learning (SCL). Explanatory mixed-method design, where quantitative strand is followed by qualitative one, is employed. While the quantitative strand aims to explore teachers' perceptions regarding the extent student-centred teacher and…

  18. Plasma inverse transition acceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Ming

    It can be proved fundamentally from the reciprocity theorem with which the electromagnetism is endowed that corresponding to each spontaneous process of radiation by a charged particle there is an inverse process which defines a unique acceleration mechanism, from Cherenkov radiation to inverse Cherenkov acceleration (ICA) [1], from Smith-Purcell radiation to inverse Smith-Purcell acceleration (ISPA) [2], and from undulator radiation to inverse undulator acceleration (IUA) [3]. There is no exception. Yet, for nearly 30 years after each of the aforementioned inverse processes has been clarified for laser acceleration, inverse transition acceleration (ITA), despite speculation [4], has remained the least understood,more » and above all, no practical implementation of ITA has been found, until now. Unlike all its counterparts in which phase synchronism is established one way or the other such that a particle can continuously gain energy from an acceleration wave, the ITA to be discussed here, termed plasma inverse transition acceleration (PITA), operates under fundamentally different principle. As a result, the discovery of PITA has been delayed for decades, waiting for a conceptual breakthrough in accelerator physics: the principle of alternating gradient acceleration [5, 6, 7, 8, 9, 10]. In fact, PITA was invented [7, 8] as one of several realizations of the new principle.« less

  19. Induction linear accelerators

    NASA Astrophysics Data System (ADS)

    Birx, Daniel

    1992-03-01

    Among the family of particle accelerators, the Induction Linear Accelerator is the best suited for the acceleration of high current electron beams. Because the electromagnetic radiation used to accelerate the electron beam is not stored in the cavities but is supplied by transmission lines during the beam pulse it is possible to utilize very low Q (typically<10) structures and very large beam pipes. This combination increases the beam breakup limited maximum currents to of order kiloamperes. The micropulse lengths of these machines are measured in 10's of nanoseconds and duty factors as high as 10-4 have been achieved. Until recently the major problem with these machines has been associated with the pulse power drive. Beam currents of kiloamperes and accelerating potentials of megavolts require peak power drives of gigawatts since no energy is stored in the structure. The marriage of liner accelerator technology and nonlinear magnetic compressors has produced some unique capabilities. It now appears possible to produce electron beams with average currents measured in amperes, peak currents in kiloamperes and gradients exceeding 1 MeV/meter, with power efficiencies approaching 50%. The nonlinear magnetic compression technology has replaced the spark gap drivers used on earlier accelerators with state-of-the-art all-solid-state SCR commutated compression chains. The reliability of these machines is now approaching 1010 shot MTBF. In the following paper we will briefly review the historical development of induction linear accelerators and then discuss the design considerations.

  20. Elderly Care Centre

    NASA Astrophysics Data System (ADS)

    Wagiman, Aliani; Haja Bava Mohidin, Hazrina; Ismail, Alice Sabrina

    2016-02-01

    The demand for elderly centre has increased tremendously abreast with the world demographic change as the number of senior citizens rose in the 21st century. This has become one of the most crucial problems of today's era. As the world progress into modernity, more and more people are occupied with daily work causing the senior citizens to lose the care that they actually need. This paper seeks to elucidate the best possible design of an elderly care centre with new approach in order to provide the best service for them by analysing their needs and suitable activities that could elevate their quality of life. All these findings will then be incorporated into design solutions so as to enhance the living environment for the elderly especially in Malaysian context.

  1. ION ACCELERATOR

    DOEpatents

    Bell, J.S.

    1959-09-15

    An arrangement for the drift tubes in a linear accelerator is described whereby each drift tube acts to shield the particles from the influence of the accelerating field and focuses the particles passing through the tube. In one embodiment the drift tube is splii longitudinally into quadrants supported along the axis of the accelerator by webs from a yoke, the quadrants. webs, and yoke being of magnetic material. A magnetic focusing action is produced by energizing a winding on each web to set up a magnetic field between adjacent quadrants. In the other embodiment the quadrants are electrically insulated from each other and have opposite polarity voltages on adjacent quadrants to provide an electric focusing fleld for the particles, with the quadrants spaced sufficienily close enough to shield the particles within the tube from the accelerating electric field.

  2. Schooling in Times of Acceleration

    ERIC Educational Resources Information Center

    Buddeberg, Magdalena; Hornberg, Sabine

    2017-01-01

    Modern societies are characterised by forms of acceleration, which influence social processes. Sociologist Hartmut Rosa has systematised temporal structures by focusing on three categories of social acceleration: technical acceleration, acceleration of social change, and acceleration of the pace of life. All three processes of acceleration are…

  3. Physiological Effects of Acceleration Observed During a Centrifuge Study of Pilot Performance

    NASA Technical Reports Server (NTRS)

    Smedal, Harald A.; Creer, Brent Y.; Wingrove, Rodney C.

    1960-01-01

    An investigation was conducted by the National Aeronautics and Space Administration, Ames Research Center, and the Naval Air Development Center, Aviation Medical Acceleration Laboratory, to study the effects of acceleration on pilot performance and to obtain some meaningful data for use in establishing tolerance to acceleration levels. The flight simulator used in the study was the Johnsville centrifuge operated as a closed loop system. The pilot was required to perform a control task in various sustained acceleration fields typical of those that Might be encountered by a pilot flying an entry vehicle in which he is seated in a forward-facing position. A special restraint system was developed and designed to increase the pilot's tolerance to these accelerations. The results of this study demonstrated that a well-trained subject, such as a test pilot, can adequately carry out a control task during moderately high accelerations for prolonged periods of time. The maximum levels of acceleration tolerated were approximately 6 times that of gravity for approximately 6 minutes, and varied slightly with the acceleration direction. The tolerance runs were in each case terminated by the subject. In all but two instances, the cause was extreme fatigue. On two occasions the subject terminated the run when he "grayed out." Although there were subjective and objective findings involving the visual and cardiovascular systems, the respiratory system yielded the more critical limiting factors. It would appear that these limiting factors were less severe during the "eyeballs-out" accelerations when compared with the "eyeballs-in" accelerations. These findings are explained on the basis of the influence that the inertial forces of acceleration have on the mechanics of respiration. A condensed version of this report was presented at the Annual Meeting of the Aerospace Medical Association, Miami Beach, May 5-11, 1960, in a paper entitled "Ability of Pilots to Perform a Control Task in

  4. The Irish Centre for Talented Youth

    ERIC Educational Resources Information Center

    Gilheany, Sheila

    2005-01-01

    Conducting potency tests on penicillin, discussing rocket technology with a NASA astronaut, analysing animal bone fragments from medieval times, these are just some of the activities which occupy the time of students at The Irish Centre for Talented Youth. The Centre identifies young students with exceptional academic ability and then provides…

  5. Documentation Centre of the Association of African Universities.

    ERIC Educational Resources Information Center

    Chateh, Peter

    This report presents the results of a study of the Documentation Centre of the Association of African Universities (AAU) undertaken to work out proposals for the rational organization of the Centre, and to explore the possibility of computerizing the Centre and linking it with other centers which provide automated documentation services. The…

  6. Prediction of scaling physics laws for proton acceleration with extended parameter space of the NIF ARC

    NASA Astrophysics Data System (ADS)

    Bhutwala, Krish; Beg, Farhat; Mariscal, Derek; Wilks, Scott; Ma, Tammy

    2017-10-01

    The Advanced Radiographic Capability (ARC) laser at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory is the world's most energetic short-pulse laser. It comprises four beamlets, each of substantial energy ( 1.5 kJ), extended short-pulse duration (10-30 ps), and large focal spot (>=50% of energy in 150 µm spot). This allows ARC to achieve proton and light ion acceleration via the Target Normal Sheath Acceleration (TNSA) mechanism, but it is yet unknown how proton beam characteristics scale with ARC-regime laser parameters. As theory has also not yet been validated for laser-generated protons at ARC-regime laser parameters, we attempt to formulate the scaling physics of proton beam characteristics as a function of laser energy, intensity, focal spot size, pulse length, target geometry, etc. through a review of relevant proton acceleration experiments from laser facilities across the world. These predicted scaling laws should then guide target design and future diagnostics for desired proton beam experiments on the NIF ARC. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and funded by the LLNL LDRD program under tracking code 17-ERD-039.

  7. ACCELERATION AND THE GIFTED.

    ERIC Educational Resources Information Center

    GIBSON, ARTHUR R.; STEPHANS, THOMAS M.

    ACCELERATION OF PUPILS AND SUBJECTS IS CONSIDERED A MEANS OF EDUCATING THE ACADEMICALLY GIFTED STUDENT. FIVE INTRODUCTORY ARTICLES PROVIDE A FRAMEWORK FOR THINKING ABOUT ACCELERATION. FIVE PROJECT REPORTS OF ACCELERATED PROGRAMS IN OHIO ARE INCLUDED. ACCELERATION IS NOW BEING REGARDED MORE FAVORABLY THAN FORMERLY, BECAUSE METHODS HAVE BEEN…

  8. Development of Acceleration Sensor and Acceleration Evaluation System for Super-Low-Range Frequencies

    NASA Astrophysics Data System (ADS)

    Asano, Shogo; Matsumoto, Hideki

    2001-05-01

    This paper describes the development process for acceleration sensors used on automobiles and an acceleration evaluation system designed specifically for acceleration at super-low-range frequencies. The features of the newly developed sensor are as follows. 1) Original piezo-bimorph design based on a disc-center-fixed structure achieves pyroeffect cancelling and stabilization of sensor characteristics and enables the detection of the acceleration of 0.0009 G at the super-low-range-frequency of 0.03 Hz. 2) The addition of a self-diagnostic function utilizing the characteristics of piezoceramics enables constant monitoring of sensor failure. The frequency range of acceleration for accurate vehicle motion control is considered to be from DC to about 50 Hz. However, the measurement of acceleration in the super-low-range frequency near DC has been difficult because of mechanical and electrical noise interruption. This has delayed the development of the acceleration sensor for automotive use. We have succeeded in the development of an acceleration evaluation system for super-low-range frequencies from 0.015 Hz to 2 Hz with detection of the acceleration range from 0.0002 G (0.2 gal) to 1 G, as well as the development of a piezoelectric-type acceleration sensor for automotive use.

  9. Acceleration: It's Elementary

    ERIC Educational Resources Information Center

    Willis, Mariam

    2012-01-01

    Acceleration is one tool for providing high-ability students the opportunity to learn something new every day. Some people talk about acceleration as taking a student out of step. In actuality, what one is doing is putting a student in step with the right curriculum. Whole-grade acceleration, also called grade-skipping, usually happens between…

  10. Accelerating Innovation Through Coopetition: The Innovation Learning Network Experience.

    PubMed

    McCarthy, Chris; Ford Carleton, Penny; Krumpholz, Elizabeth; Chow, Marilyn P

    Coopetition, the simultaneous pursuit of cooperation and competition, is a growing force in the innovation landscape. For some organizations, the primary mode of innovation continues to be deeply secretive and highly competitive, but for others, a new style of shared challenges, shared purpose, and shared development has become a superior, more efficient way of working to accelerate innovation capabilities and capacity. Over the last 2 decades, the literature base devoted to coopetition has gradually expanded. However, the field is still in its infancy. The majority of coopetition research is qualitative, primarily consisting of case studies. Few studies have addressed the nonprofit sector or service industries such as health care. The authors believe that this article may offer a unique perspective on coopetition in the context of a US-based national health care learning alliance designed to accelerate innovation, the Innovation Learning Network or ILN. The mission of the ILN is to "Share the joy and pain of innovation," accelerating innovation by sharing solutions, teaching techniques, and cultivating friendships. These 3 pillars (sharing, teaching, and cultivating) form the foundation for coopetition within the ILN. Through the lens of coopetition, we examine the experience of the ILN over the last 10 years and provide case examples that illustrate the benefits and challenges of coopetition in accelerating innovation in health care.

  11. UK Renal Registry 16th annual report: chapter 12 biochemical variables amongst UK adult dialysis patients in 2012: national and centre-specific analyses.

    PubMed

    Nicholas, Johann; Shaw, Catriona; Pitcher, David; Dawnay, Anne

    2013-01-01

    The UK Renal Association clinical practice guidelines include clinical performance measures for biochemical variables in dialysis patients. The UK Renal Registry (UKRR) annually audits dialysis centre performance against these measures as part of its role in promoting continuous quality improvement. Cross sectional performance analyses were undertaken to compare dialysis centre achievement of clinical audit measures for prevalent haemodialysis (HD) and peritoneal dialysis (PD) cohorts in 2012. The biochemical variables studied were phosphate, adjusted calcium, parathyroid hormone, bicarbonate and total cholesterol. In addition, longitudinal analyses were performed (2002-2012) to show changes in achievement of clinical performance measures over time. Fifty-six percent of HD and 61% of PD patients achieved a phosphate within the range recommended by the RA clinical practice guidelines. Seventy-seven percent of HD and 78% of PD patients had adjusted calcium between 2.2-2.5 mmol/L. Fifty-eight percent of HD and 65% of PD patients had parathyroid hormone between 16-72 pmol/L. Fifty-nine percent of HD and 80% of PD patients achieved the audit measure for bicarbonate. There was significant inter-centre variation for all variables studied. The UKRR consistently demonstrates significant inter-centre variation in achievement of biochemical clinical audit measures. Understanding the causes of this variation is an important part of improving the care of dialysis patients in the UK.

  12. The haemtrack home therapy reporting system: Design, implementation, strengths and weaknesses: A report from UK Haemophilia Centre Doctors Organisation.

    PubMed

    Hay, C R M; Xiang, H; Scott, M; Collins, P W; Liesner, R; Dolan, G; Hollingsworth, R

    2017-09-01

    Haemtrack is an electronic home treatment diary for patients with inherited bleeding disorders, introduced in 2008. It aimed to improve the timeliness and completeness of patient-reported treatment records, to facilitate analysis of treatment and outcome trends. The system is easy to use, responsive and accessible. The software uses Microsoft technologies with a SQL Server database and an ASP.net website front-end, running on personal computers, android and I-phones. Haemtrack interfaces with the UK Haemophilia Centre Information System and the National Haemophilia Database (NHD). Data are validated locally by Haemophilia Centres and centrally by NHD. Data collected include as follows: treatment brand, dose and batch number, time/date of bleed onset and drug administration, reasons for treatment (prophylaxis, bleed, follow-up), bleed site, severity, pain-score and outcome. Haemtrack was used by 90% of haemophilia treatment centres (HTCs) in 2015, registering 2683 patients using home therapy of whom 1923 used Haemtrack, entering >17 000 treatments per month. This included 68% of all UK patients with severe haemophilia A. Reporting compliance varied and 55% of patients reported ≥75% of potential usage. Centres had a median 78% compliance overall. A strategy for progressively improving compliance is in place. Age distribution and treatment intensity were similar in Haemtrack users/non-users with severe haemophilia treated prophylactically. The Haemtrack system is a valuable tool that may improve treatment compliance and optimize treatment regimen. Analysis of national treatment trends and large-scale longitudinal, within-patient analysis of changes in regimen and/or product will provide valuable insights that will guide future clinical practice. © 2017 John Wiley & Sons Ltd.

  13. [The Adamant, an unusual care centre].

    PubMed

    Khidichian, Frédéric

    2011-01-01

    The day care centre of the central Paris area has established itself in an unusual location--a 650 m2 floating building moored on the right bank of the Seine. Patients and caregivers were involved in the design of this original and ecological care centre, which places the emphasis on comfort and safety.

  14. An investigation of two phase flow pressure drops in a reduced acceleration environment

    NASA Astrophysics Data System (ADS)

    Wheeler, Montgomery W.; Best, Frederick R.; Reinarts, Thomas R.

    1993-01-01

    Thermal systems for space applications based on two phase flow have several advantages over single phase systems. Two phase thermal energy management and dynamic power conversion system advantages include the capability of achieving high specific power levels. Before two phase systems for space applications can be designed effectively, knowledge of the flow behavior in a reduced acceleration environment is necessary. To meet these needs, two phase flow experiments were conducted aboard the National Aeronautic and Space Administration's KC-135 using R12 as the working fluid. Annular flow two phase pressure drops were measured through 10.41-mm ID 1.251-m long glass tubing during periods with acceleration levels in the range ±0.05 G. The experiments were conducted with emphasis on achieving data with a high level of accuracy. The reduced acceleration annular flow pressure drops were compred with pressure drops measured in a 1-G environment for similar flow conditions. The reduced acceleration pressure drops were found to be 45% greater than the 1-G pressure drops. In addition, the reduced acceleration annular flow interfacial friction factors were compared with models for vertical up-flow in a 1-G environment. The reduced acceleration interfacial friction factor data was not predicted by the 1-G models.

  15. Terahertz-driven linear electron acceleration

    PubMed Central

    Nanni, Emilio A.; Huang, Wenqian R.; Hong, Kyung-Han; Ravi, Koustuban; Fallahi, Arya; Moriena, Gustavo; Dwayne Miller, R. J.; Kärtner, Franz X.

    2015-01-01

    The cost, size and availability of electron accelerators are dominated by the achievable accelerating gradient. Conventional high-brightness radio-frequency accelerating structures operate with 30–50 MeV m−1 gradients. Electron accelerators driven with optical or infrared sources have demonstrated accelerating gradients orders of magnitude above that achievable with conventional radio-frequency structures. However, laser-driven wakefield accelerators require intense femtosecond sources and direct laser-driven accelerators suffer from low bunch charge, sub-micron tolerances and sub-femtosecond timing requirements due to the short wavelength of operation. Here we demonstrate linear acceleration of electrons with keV energy gain using optically generated terahertz pulses. Terahertz-driven accelerating structures enable high-gradient electron/proton accelerators with simple accelerating structures, high repetition rates and significant charge per bunch. These ultra-compact terahertz accelerators with extremely short electron bunches hold great potential to have a transformative impact for free electron lasers, linear colliders, ultrafast electron diffraction, X-ray science and medical therapy with X-rays and electron beams. PMID:26439410

  16. Terahertz-driven linear electron acceleration

    DOE PAGES

    Nanni, Emilio A.; Huang, Wenqian R.; Hong, Kyung-Han; ...

    2015-10-06

    The cost, size and availability of electron accelerators are dominated by the achievable accelerating gradient. Conventional high-brightness radio-frequency accelerating structures operate with 30–50 MeVm -1 gradients. Electron accelerators driven with optical or infrared sources have demonstrated accelerating gradients orders of magnitude above that achievable with conventional radio-frequency structures. However, laser-driven wakefield accelerators require intense femtosecond sources and direct laser-driven accelerators suffer from low bunch charge, sub-micron tolerances and sub-femtosecond timing requirements due to the short wavelength of operation. Here we demonstrate linear acceleration of electrons with keV energy gain using optically generated terahertz pulses. Terahertz-driven accelerating structures enable high-gradient electron/protonmore » accelerators with simple accelerating structures, high repetition rates and significant charge per bunch. As a result, these ultra-compact terahertz accelerators with extremely short electron bunches hold great potential to have a transformative impact for free electron lasers, linear colliders, ultrafast electron diffraction, X-ray science and medical therapy with X-rays and electron beams.« less

  17. Laser driven ion accelerator

    DOEpatents

    Tajima, Toshiki

    2006-04-18

    A system and method of accelerating ions in an accelerator to optimize the energy produced by a light source. Several parameters may be controlled in constructing a target used in the accelerator system to adjust performance of the accelerator system. These parameters include the material, thickness, geometry and surface of the target.

  18. High brightness electron accelerator

    DOEpatents

    Sheffield, Richard L.; Carlsten, Bruce E.; Young, Lloyd M.

    1994-01-01

    A compact high brightness linear accelerator is provided for use, e.g., in a free electron laser. The accelerator has a first plurality of acclerating cavities having end walls with four coupling slots for accelerating electrons to high velocities in the absence of quadrupole fields. A second plurality of cavities receives the high velocity electrons for further acceleration, where each of the second cavities has end walls with two coupling slots for acceleration in the absence of dipole fields. The accelerator also includes a first cavity with an extended length to provide for phase matching the electron beam along the accelerating cavities. A solenoid is provided about the photocathode that emits the electons, where the solenoid is configured to provide a substantially uniform magnetic field over the photocathode surface to minimize emittance of the electons as the electrons enter the first cavity.

  19. Test results of a Nb 3Al/Nb 3Sn subscale magnet for accelerator application

    DOE PAGES

    Iio, Masami; Xu, Qingjin; Nakamoto, Tatsushi; ...

    2015-01-28

    The High Energy Accelerator Research Organization (KEK) has been developing a Nb 3Al and Nb 3Sn subscale magnet to establish the technology for a high-field accelerator magnet. The development goals are a feasibility demonstration for a Nb 3Al cable and the technology acquisition of magnet fabrication with Nb 3Al superconductors. KEK developed two double-pancake racetrack coils with Rutherford-type cables composed of 28 Nb 3Al wires processed by rapid heating, quenching, and transformation in collaboration with the National Institute for Materials Science and the Fermi National Accelerator Laboratory. The magnet was fabricated to efficiently generate a high magnetic field in amore » minimum-gap common-coil configuration with two Nb 3Al coils sandwiched between two Nb 3Sn coils produced by the Lawrence Berkeley National Laboratory. A shell-based structure and a “bladder and key” technique have been used for adjusting coil prestress during both the magnet assembly and the cool down. In the first excitation test of the magnet at 4.5 K performed in June 2014, the highest quench current of the Nb 3Sn coil, i.e., 9667 A, was reached at 40 A/s corresponding to 9.0 T in the Nb 3Sn coil and 8.2 T in the Nb 3Al coil. The quench characteristics of the magnet were studied.« less

  20. Centre of the Cell: Science Comes to Life.

    PubMed

    Balkwill, Frances; Chambers, Katie

    2015-01-01

    Centre of the Cell is a unique biomedical science education centre, a widening participation and outreach project in London's East End. This article describes Centre of the Cell's first five years of operation, the evolution of the project in response to audience demand, and the impact of siting a major public engagement project within a research laboratory.

  1. Acceleration of a trailing positron bunch in a plasma wakefield accelerator

    DOE PAGES

    Doche, A.; Beekman, C.; Corde, S.; ...

    2017-10-27

    High gradients of energy gain and high energy efficiency are necessary parameters for compact, cost-efficient and high-energy particle colliders. Plasma Wakefield Accelerators (PWFA) offer both, making them attractive candidates for next-generation colliders. Here in these devices, a charge-density plasma wave is excited by an ultra-relativistic bunch of charged particles (the drive bunch). The energy in the wave can be extracted by a second bunch (the trailing bunch), as this bunch propagates in the wake of the drive bunch. While a trailing electron bunch was accelerated in a plasma with more than a gigaelectronvolt of energy gain, accelerating a trailing positronmore » bunch in a plasma is much more challenging as the plasma response can be asymmetric for positrons and electrons. We report the demonstration of the energy gain by a distinct trailing positron bunch in a plasma wakefield accelerator, spanning nonlinear to quasi-linear regimes, and unveil the beam loading process underlying the accelerator energy efficiency. A positron bunch is used to drive the plasma wake in the experiment, though the quasi-linear wake structure could as easily be formed by an electron bunch or a laser driver. Finally, the results thus mark the first acceleration of a distinct positron bunch in plasma-based particle accelerators.« less

  2. Acceleration of a trailing positron bunch in a plasma wakefield accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doche, A.; Beekman, C.; Corde, S.

    High gradients of energy gain and high energy efficiency are necessary parameters for compact, cost-efficient and high-energy particle colliders. Plasma Wakefield Accelerators (PWFA) offer both, making them attractive candidates for next-generation colliders. Here in these devices, a charge-density plasma wave is excited by an ultra-relativistic bunch of charged particles (the drive bunch). The energy in the wave can be extracted by a second bunch (the trailing bunch), as this bunch propagates in the wake of the drive bunch. While a trailing electron bunch was accelerated in a plasma with more than a gigaelectronvolt of energy gain, accelerating a trailing positronmore » bunch in a plasma is much more challenging as the plasma response can be asymmetric for positrons and electrons. We report the demonstration of the energy gain by a distinct trailing positron bunch in a plasma wakefield accelerator, spanning nonlinear to quasi-linear regimes, and unveil the beam loading process underlying the accelerator energy efficiency. A positron bunch is used to drive the plasma wake in the experiment, though the quasi-linear wake structure could as easily be formed by an electron bunch or a laser driver. Finally, the results thus mark the first acceleration of a distinct positron bunch in plasma-based particle accelerators.« less

  3. Accelerator-based BNCT.

    PubMed

    Kreiner, A J; Baldo, M; Bergueiro, J R; Cartelli, D; Castell, W; Thatar Vento, V; Gomez Asoia, J; Mercuri, D; Padulo, J; Suarez Sandin, J C; Erhardt, J; Kesque, J M; Valda, A A; Debray, M E; Somacal, H R; Igarzabal, M; Minsky, D M; Herrera, M S; Capoulat, M E; Gonzalez, S J; del Grosso, M F; Gagetti, L; Suarez Anzorena, M; Gun, M; Carranza, O

    2014-06-01

    The activity in accelerator development for accelerator-based BNCT (AB-BNCT) both worldwide and in Argentina is described. Projects in Russia, UK, Italy, Japan, Israel, and Argentina to develop AB-BNCT around different types of accelerators are briefly presented. In particular, the present status and recent progress of the Argentine project will be reviewed. The topics will cover: intense ion sources, accelerator tubes, transport of intense beams, beam diagnostics, the (9)Be(d,n) reaction as a possible neutron source, Beam Shaping Assemblies (BSA), a treatment room, and treatment planning in realistic cases. © 2013 Elsevier Ltd. All rights reserved.

  4. Accelerators for Discovery Science and Security applications

    NASA Astrophysics Data System (ADS)

    Todd, A. M. M.; Bluem, H. P.; Jarvis, J. D.; Park, J. H.; Rathke, J. W.; Schultheiss, T. J.

    2015-05-01

    Several Advanced Energy Systems (AES) accelerator projects that span applications in Discovery Science and Security are described. The design and performance of the IR and THz free electron laser (FEL) at the Fritz-Haber-Institut der Max-Planck-Gesellschaft in Berlin that is now an operating user facility for physical chemistry research in molecular and cluster spectroscopy as well as surface science, is highlighted. The device was designed to meet challenging specifications, including a final energy adjustable in the range of 15-50 MeV, low longitudinal emittance (<50 keV-psec) and transverse emittance (<20 π mm-mrad), at more than 200 pC bunch charge with a micropulse repetition rate of 1 GHz and a macropulse length of up to 15 μs. Secondly, we will describe an ongoing effort to develop an ultrafast electron diffraction (UED) source that is scheduled for completion in 2015 with prototype testing taking place at the Brookhaven National Laboratory (BNL) Accelerator Test Facility (ATF). This tabletop X-band system will find application in time-resolved chemical imaging and as a resource for drug-cell interaction analysis. A third active area at AES is accelerators for security applications where we will cover some top-level aspects of THz and X-ray systems that are under development and in testing for stand-off and portal detection.

  5. SuperB Progress Report for Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biagini, M.E.; Boni, R.; Boscolo, M.

    2012-02-14

    national laboratories. In Italy these may include INFN Frascati and the University of Pisa, in the United States SLAC, LBNL, BNL and several universities, in France IN2P3, LAPP, and Grenoble, in Russia BINP, in Poland Krakow University, and in the UK the Cockcroft Institute. The construction time for this collider is a total of about four years. The new tunnel can be bored in about a year. The new accelerator components can be built and installed in about 4 years. The shipping of components from PEP-II at SLAC to Italy will take about a year. A new linac and damping ring complex for the injector for the rings can be built in about three years. The commissioning of this new accelerator will take about a year including the new electron and positron sources, new linac, new damping ring, new beam transport lines, two new collider rings and the Interaction Region. The new particle physics detector can be commissioned simultaneously with the accelerator. Once beam collisions start for particle physics, the luminosity will increase with time, likely reaching full design specifications after about two to three years of operation. After construction, the operation of the collider will be the responsibility of the Italian INFN governmental agency. The intent is to run this accelerator about ten months each year with about one month for accelerator turn-on and nine months for colliding beams. The collider will need to operate for about 10 years to provide the required 50 ab{sup -1} requested by the detector collaboration. Both beams as anticipated in this collider will have properties that are excellent for use as sources for synchrotron radiation (SR). The expected photon properties are comparable to those of PETRA-3 or NSLS-II. The beam lines and user facilities needed to carry out this SR program are being investigated.« less

  6. National Fire Plan Research and Development 2001 Business Summary

    Treesearch

    USDA Forest Service

    2002-01-01

    Wildland fire remains a serious concern to the people of our Nation. This concern has been turned into action in the form of the National Fire Plan (NFP), an accelerated interagency effort, begun after the disastrous 2000 fire season, to step up, coordinate, and concentrate activity on reducing fire risks.

  7. Real-time and accelerated outdoor endurance testing of solar cells

    NASA Technical Reports Server (NTRS)

    Forestieri, A. F.; Anagnostou, E.

    1977-01-01

    Real-time and accelerated outdoor endurance testing was performed on a variety of samples of interest to the National Photovoltaic Conversion Program. The real-time tests were performed at seven different sites and the accelerated tests were performed at one of those sites in the southwestern United States. The purpose of the tests were to help evaluate the lifetime of photovoltaic systems. Three types of samples were tested; transmission samples of possible cover materials, sub-modules constructed using these materials attached to solar cells, and solar cell modules produced by the manufacturers for the ERDA program. Results indicate that suitable cover materials are glass, FEP-A and PFA. Dirt accumulation and cleanability are important factors in the selection of solar cell module covers and encapsulants.

  8. Assessing Learners' Satisfication towards Support Services Delivery in National Open University Nigeria: Implications for Counselling Services

    ERIC Educational Resources Information Center

    Okopi, Fidel; Ofole, Ndidi

    2013-01-01

    This study aims at determining the level of students' satisfaction of learner support services in the study centres of NOUN--National Open University of Nigeria and whether the support services offered at the study centres have significant influence on the level of students' satisfaction. A descriptive survey of ex-post facto research design was…

  9. Access to yellow fever travel vaccination centres in England, Wales, and Northern Ireland: A geographical study.

    PubMed

    Petersen, Jakob; Simons, Hilary; Patel, Dipti

    More than 700,000 trips were made by residents in England, Wales, and Northern Ireland (EWNI) in 2015 to tropical countries endemic for yellow fever, a potentially deadly, yet vaccine-preventable disease transmitted by mosquitoes. The aim of this study was to map the geographical accessibility of yellow fever vaccination centres (YFVC) in EWNI. The location of 3208 YFVC were geocoded and the average geodetic distance to nearest YFVC was calculated for each population unit. Data on trips abroad and centres were obtained regionally for EWNI and nationally for the World Top20 countries in terms of travel. The mean distance to nearest YFVC was 2.4 km and only 1% of the population had to travel more than 16.1 km to their nearest centre. The number of vaccines administered regionally in EWNI was found correlated with the number of trips to yellow fever countries. The number of centres per 100,000 trips was 6.1 in EWNI, which was below United States (12.1) and above the rest of Top20 countries. The service availability was in line with demand regionally. With the exception of remote, rural areas, yellow fever vaccination services were widely available with only short distances to cover for the travelling public. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  10. Waste management in primary healthcare centres of Iran.

    PubMed

    Mesdaghinia, Alireza; Naddafi, Kazem; Mahvi, Amir Hossein; Saeedi, Reza

    2009-06-01

    The waste management practices in primary healthcare centres of Iran were investigated in the present study. A total of 120 primary healthcare centres located across the country were selected using the cluster sampling method and the current situation of healthcare waste management was determined through field investigation. The quantities of solid waste and wastewater generation per outpatient were found to be 60 g outpatient(-1) day(-1) and 26 L outpatient(-1) day(-1), respectively. In all of the facilities, sharp objects were separated almost completely, but separation of other types of hazardous healthcare solid waste was only done in 25% of the centres. The separated hazardous solid waste materials were treated by incineration, temporary incineration and open burning methods in 32.5, 8.3 and 42.5% of the healthcare centres, respectively. In 16.7% of the centres the hazardous solid wastes were disposed of without any treatment. These results indicate that the management of waste materials in primary healthcare centres in Iran faced some problems. Staff training and awareness, separation of healthcare solid waste, establishment of the autoclave method for healthcare solid waste treatment and construction of septic tanks and disinfection units in the centres that were without access to a sewer system are the major measures that are suggested for improvement of the waste management practices.

  11. Learner-centred teaching in a non-learner-centred world: An interpretive phenomenological study of the lived experience of clinical nursing faculty.

    PubMed

    Oyelana, Olabisi; Martin, Donna; Scanlan, Judith; Temple, Beverley

    2018-08-01

    With the growing complexities in the contemporary health care system, there is a challenge of preparing nurses for the practice demands. To this end, learner-centred teaching has emerged in many nursing curricula in Canada and evidence indicates its effectiveness in developing the essential practice skills in nursing students. It is important to examine the experience of the clinical faculty members who implement learner-centred teaching, as doing so would provide an insight to the factors that may hinder the implementation of learner-centred teaching in the practice settings. This phenomenological study aimed to address two research questions: what does learner-centred teaching mean to clinical nurse faculty? What is the lived experience of clinical nursing faculty who incorporate learner-centred teaching? Ten clinical nurse faculty members who had at least two years of clinical teaching experience volunteered to participate in the study. Data were collected using a semi-structured interview guide and audio recorder. Additional data sources included a demographic survey and a reflective journal. Multiple sub-themes emerged from this study from which three significant themes were consolidated: diversity of meanings, facilitators of LCT, and barriers to LCT. However, an overarching theme of "learner-centred teaching in a non-learner-centred world" was coined from participants' accounts of their experiences of barriers in incorporating LCT in the practice settings. A collaborative effort between faculty and the stakeholders is paramount to a successful implementation of learner-centred teaching in practice settings. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. ALON® Components With Tunable Dielectric Properties for High Power Accelerator Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldman, Lee M; Jha, Santosh K; Lobur, Nicole

    There are challenges in linear particle accelerators associated with the need to suppress “higher order modes” (HOMs). HOMs are detrimental to accelerator operation as they are a source of beam instability. The absorption/suppression of HOMs and dissipation of the energy of higher order modes is vital to the function of these accelerators. Surmet has identified ALON® Optical Ceramic (Aluminum Oxynitride), a hard, durable ceramic that is fabricated through conventional powder processing techniques, as a potential material for HOM absorber. In this Phase I program, Surmet has produced new ALON-composite HOM absorber materials that function at both ambient and cryogenic temperatures.more » The composite materials were developed and evaluated in collaboration with Thomas Jefferson National Labs. Success in this Phase I and the potential Phase II will demonstrate the utility of ALON composite components for RF absorbing applications and lay the groundwork for commercialization of such products, with applications in basic science, medical and digital electronics industries.« less

  13. The accelerated site technology deployment program presents the segmented gate system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PATTESON,RAYMOND; MAYNOR,DOUG; CALLAN,CONNIE

    2000-02-24

    The Department of Energy (DOE) is working to accelerate the acceptance and application of innovative technologies that improve the way the nation manages its environmental remediation problems. The DOE Office of Science and Technology established the Accelerated Site Technology Deployment Program (ASTD) to help accelerate the acceptance and implementation of new and innovative soil and ground water remediation technologies. Coordinated by the Department of Energy's Idaho Office, the ASTD Program reduces many of the classic barriers to the deployment of new technologies by involving government, industry, and regulatory agencies in the assessment, implementation, and validation of innovative technologies. The papermore » uses the example of the Segmented Gate System (SGS) to illustrate how the ASTD program works. The SGS was used to cost effectively separate clean and contaminated soil for four different radionuclides: plutonium, uranium, thorium, and cesium. Based on those results, it has been proposed to use the SGS at seven other DOE sites across the country.« less

  14. Person-centred rehabilitation: what exactly does it mean? Protocol for a scoping review with thematic analysis towards framing the concept and practice of person-centred rehabilitation.

    PubMed

    Jesus, Tiago S; Bright, Felicity; Kayes, Nicola; Cott, Cheryl A

    2016-07-19

    Person-centredness is a philosophy for organising and delivering healthcare based on patients' needs, preferences and experiences. Although widely endorsed, the concept suffers from a lack of detail and clarification, in turn accounting for ambiguous implementation and outcomes. While a conceptual framework based on a systematic review defines person/patient-centred care components (Scholl et al, 2014), it applies across healthcare contexts and may not be sensitive to the nuances of the rehabilitation of adults with physical impairments. Accordingly, this study aims to build a conceptual framework, based on existing literature, of what person-centredness means in the rehabilitation of adults with physical impairments in the clinical encounter and broader health service delivery. We will use a scoping review methodology. Searches on relevant databases will be conducted first, combining keywords for 'rehabilitation', 'person-centered' and associated terms (including patient preferences/experiences). Next, snowball searches (citation tracking, references lists) will be performed. Papers will be included if they fall within predefined selection categories (seen as most likely informative on elements pertaining to person-centred rehabilitation) and are written in English, regardless of design (conceptual, qualitative, quantitative). Two reviewers will independently screen titles and abstracts, followed by screening of the full text to determine inclusion. Experts will then be consulted to identify relevant missing papers. This can include elements other than the peer-reviewed literature (eg, book chapters, policy/legal papers). Finally, information that helps to build the concept and practice of person-centred rehabilitation will be abstracted independently by two reviewers and analysed by inductive thematic analysis to build the conceptual framework. The resulting framework will aid clarification regarding person-centred rehabilitation, which in turn is expected to

  15. Person-centred rehabilitation: what exactly does it mean? Protocol for a scoping review with thematic analysis towards framing the concept and practice of person-centred rehabilitation

    PubMed Central

    Bright, Felicity; Kayes, Nicola; Cott, Cheryl A

    2016-01-01

    person-centred rehabilitation, which in turn is expected to conceptually ground and inform its operationalisation (eg, measurement, implementation, improvement). Findings will be disseminated through local, national and international stakeholders, both at the clinical and service organisation levels. PMID:27436670

  16. Reconciling evidence‐based medicine and patient‐centred care: defining evidence‐based inputs to patient‐centred decisions

    PubMed Central

    2015-01-01

    Abstract Evidence‐based and patient‐centred health care movements have each enhanced the discussion of how health care might best be delivered, yet the two have evolved separately and, in some views, remain at odds with each other. No clear model has emerged to enable practitioners to capitalize on the advantages of each so actual practice often becomes, to varying degrees, an undefined mishmash of each. When faced with clinical uncertainty, it becomes easy for practitioners to rely on formulas for care developed explicitly by expert panels, or on the tacit ones developed from experience or habit. Either way, these tendencies towards ‘cookbook’ medicine undermine the view of patients as unique particulars, and diminish what might be considered patient‐centred care. The sequence in which evidence is applied in the care process, however, is critical for developing a model of care that is both evidence based and patient centred. This notion derives from a paradigm for knowledge delivery and patient care developed over decades by Dr. Lawrence Weed. Weed's vision enables us to view evidence‐based and person‐centred medicine as wholly complementary, using computer tools to more fully and reliably exploit the vast body of collective knowledge available to define patients’ uniqueness and identify the options to guide patients. The transparency of the approach to knowledge delivery facilitates meaningful practitioner–patient dialogue in determining the appropriate course of action. Such a model for knowledge delivery and care is essential for integrating evidence‐based and patient‐centred approaches. PMID:26456314

  17. Reconciling evidence-based medicine and patient-centred care: defining evidence-based inputs to patient-centred decisions.

    PubMed

    Weaver, Robert R

    2015-12-01

    Evidence-based and patient-centred health care movements have each enhanced the discussion of how health care might best be delivered, yet the two have evolved separately and, in some views, remain at odds with each other. No clear model has emerged to enable practitioners to capitalize on the advantages of each so actual practice often becomes, to varying degrees, an undefined mishmash of each. When faced with clinical uncertainty, it becomes easy for practitioners to rely on formulas for care developed explicitly by expert panels, or on the tacit ones developed from experience or habit. Either way, these tendencies towards 'cookbook' medicine undermine the view of patients as unique particulars, and diminish what might be considered patient-centred care. The sequence in which evidence is applied in the care process, however, is critical for developing a model of care that is both evidence based and patient centred. This notion derives from a paradigm for knowledge delivery and patient care developed over decades by Dr. Lawrence Weed. Weed's vision enables us to view evidence-based and person-centred medicine as wholly complementary, using computer tools to more fully and reliably exploit the vast body of collective knowledge available to define patients' uniqueness and identify the options to guide patients. The transparency of the approach to knowledge delivery facilitates meaningful practitioner-patient dialogue in determining the appropriate course of action. Such a model for knowledge delivery and care is essential for integrating evidence-based and patient-centred approaches. © 2015 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley & Sons, Ltd.

  18. The Role of Parents' Educational Level and Centre Type in Parent Satisfaction with Early Childhood Care Centres: A Study in Greece

    ERIC Educational Resources Information Center

    Kelesidou, Sofia; Chatzikou, Maria; Tsiamagka, Evmorfia; Koutra, Evangelia; Abakoumkin, Georgios; Tseliou, Eleftheria

    2017-01-01

    This research examines specific facets of parent satisfaction with childcare centres, namely satisfaction with parent-centre communication and the educational services they provide, as well as respective parent beliefs. These were investigated in relation to centre type (private vs public) and parents' education. Parents of different educational…

  19. The GNSS data processing component within the Indonesian tsunami early warning centre provided by GITEWS

    NASA Astrophysics Data System (ADS)

    Bartsch, M.; Merx, A.; Falck, C.; Ramatschi, M.

    2010-05-01

    movements which can occur, e.g., due to strong earthquakes. The ground motion information is a valuable source for a fast understanding of an earthquake's mechanism and consequences with possible relevance for a potentially following tsunami. Regarding kinematic coordinates of a buoy only the vertical component is of interest as it corresponds to the instant sea level. The kinematic coordinates are delivered to an oceanographic post-processing unit which applies dipping-, tilting- and tidal-corrections to the data. Deviations to the mean sea level are an indicator for a possibly passing tsunami wave. By this means the GNSS system supports the decision finding process whether a tsunami has been released or not. A graphical user interface (GUI) was developed which monitors the whole processing chain from data transmission and GNSS data processing to the displaying of the kinematic coordinate time series. It supports both, a quick view for all staff members at the warning centre (24h/7d shifts) and deeper analysis by GNSS experts. The GNSS GUI system is web-based and allows all views to be displayed on different screens at the same time, even at remote locations. This is part of the concept, as it can support the dialogue between warning centre staff on duty or on standby and sensor station maintenance staff. Acknowledgements The GITEWS project (German Indonesian Tsunami Early Warning System) is carried out by a large group of scientists and engineers from (GFZ) German Research Centre for Geosciences and its partners from the German Aerospace Centre (DLR), the Alfred Wegener Institute for Polar and Marine Research (AWI), the GKSS Research Centre, the Konsortium Deutsche Meeresforschung (KDM), the Leibniz Institute for Marine Sciences (IFM-GEOMAR), the United Nations University (UNU), the Federal Institute for Geosciences and Natural Resources (BGR), the German Agency for Technical Cooperation (GTZ) and other international partners. Most relevant partners in Indonesia with

  20. Psychiatric intervention and repeated admission to emergency centres due to drug overdose.

    PubMed

    Kanehara, Akiko; Yamana, Hayato; Yasunaga, Hideo; Matsui, Hiroki; Ando, Shuntaro; Okamura, Tsuyoshi; Kumakura, Yousuke; Fushimi, Kiyohide; Kasai, Kiyoto

    2015-10-01

    Repeated drug overdose is a major risk factor for suicide. Data are lacking on the effect of psychiatric intervention on preventing repeated drug overdose. To investigate whether psychiatric intervention was associated with reduced readmission to emergency centres due to drug overdose. Using a Japanese national in-patient database, we identified patients who were first admitted to emergency centres for drug overdose in 2010-2012. We used propensity score matching for patient and hospital factors to compare readmission rates between intervention (patients undergoing psychosocial assessment) and unexposed groups. Of 29 564 eligible patients, 13 035 underwent psychiatric intervention. In the propensity-matched 7938 pairs, 1304 patients were readmitted because of drug overdose. Readmission rate was lower in the intervention than in the unexposed group (7.3% v . 9.1% respectively, P <0.001). Psychiatric intervention was associated with reduced readmission in patients who had taken a drug overdose. None. © The Royal College of Psychiatrists 2015. This is an open access article distributed under the terms of the Creative Commons Non-Commercial, No Derivatives (CC BY-NC-ND) licence.

  1. Socioeconomic predictors of referral to a diagnostic centre on suspected adverse events following HPV vaccination.

    PubMed

    Weye, Nanna; Fonager, Kirsten; Lützen, Tina; Rytter, Dorte

    2018-05-25

    In Denmark, the human papillomavirus (HPV) vaccines have been suspected of adverse events since 2014. However, as no causal associations between the HPV vaccines and numerous diseases have been demonstrated, factors prior to vaccination may influence the risk of suspecting the HPV vaccines of causing symptoms. We studied the associations between individual and parental socioeconomic characteristics and the risk of referral to a diagnostic centre in a female population aged 11-29 years with a first HPV vaccination in January 2008 to June 2015. Individual and parental data from national registries were linked using the unique personal identification number. Logistic regression analyses were used to estimate crude and adjusted odds ratio's according to each individual and parental socioeconomic factor with two-sided 95% 95% CI. The cohort consisted of 453 216 individuals of which 1316 (0.29%) were referred to a diagnostic centre in 2015. Having a mother outside the workforce or an unemployed mother was associated with an increased risk of referral, while girls and women who had fathers with a higher educational level were less likely to be referred. In addition, women aged 20-29 years who were unemployed or outside the workforce prior to vaccination had increased odds of being referred to a diagnostic centre. We found social inequality in the referral to a diagnostic centre following HPV vaccination. This might be explained by an increased morbidity in girls and women of lower socioeconomic status.

  2. Addiction research centres and the nurturing of creativity The Norwegian Centre for Addiction Research (SERAF).

    PubMed

    Bramness, Jørgen G; Clausen, Thomas; Duckert, Fanny; Ravndal, Edle; Waal, Helge

    2011-08-01

    The Norwegian Centre for Addiction Research (SERAF) at the University of Oslo is a newly established, clinical addiction research centre. It is located at the Oslo University Hospital and has a major focus on opioid dependency, investigating Norwegian opioid maintenance treatment (OMT), with special interest in OMT during pregnancy, mortality, morbidity and criminality before, during and after OMT and alternatives to OMT, such as the use of naltrexone implants. The well-developed health registries of Norway are core assets that also allow the opportunity for other types of substance abuse research. This research includes health services, abuse of prescription drugs and drugs of abuse in connection with traffic. The centre also focuses upon comorbidity, investigating the usefulness and limitations of psychometric instruments, drug abuse in different psychiatric treatment settings and internet-based interventions for hazardous alcohol consumption. © 2010 The Authors, Addiction © 2010 Society for the Study of Addiction.

  3. National Array of Neutron Detectors (NAND): A versatile tool for nuclear reaction studies

    NASA Astrophysics Data System (ADS)

    Golda, K. S.; Jhingan, A.; Sugathan, P.; Singh, Hardev; Singh, R. P.; Behera, B. R.; Mandal, S.; Kothari, A.; Gupta, Arti; Zacharias, J.; Archunan, M.; Barua, P.; Venkataramanan, S.; Bhowmik, R. K.; Govil, I. M.; Datta, S. K.; Chatterjee, M. B.

    2014-11-01

    The first phase of the National Array of Neutron Detectors (NAND) consisting of 26 neutron detectors has been commissioned at the Inter University Accelerator Centre (IUAC), New Delhi. The motivation behind setting up of such a detector system is the need for more accurate and efficient study of reaction mechanisms in the projectile energy range of 5-8 MeV/n using heavy ion beams from a 15 UD Pelletron and an upgraded LINAC booster facility at IUAC. The above detector array can be used for inclusive as well as exclusive measurements of reaction products of which at least one product is a neutron. While inclusive measurements can be made using only the neutron detectors along with the time of flight technique and a pulsed beam, exclusive measurements can be performed by detecting neutrons in coincidence with charged particles and/or fission fragments detected with ancillary detectors. The array can also be used for neutron tagged gamma-ray spectroscopy in (HI, xn) reactions by detecting gamma-rays in coincidence with the neutrons in a compact geometrical configuration. The various features and the performance of the different aspects of the array are described in the present paper.

  4. Systems and methods for the magnetic insulation of accelerator electrodes in electrostatic accelerators

    DOEpatents

    Grisham, Larry R

    2013-12-17

    The present invention provides systems and methods for the magnetic insulation of accelerator electrodes in electrostatic accelerators. Advantageously, the systems and methods of the present invention improve the practically obtainable performance of these electrostatic accelerators by addressing, among other things, voltage holding problems and conditioning issues. The problems and issues are addressed by flowing electric currents along these accelerator electrodes to produce magnetic fields that envelope the accelerator electrodes and their support structures, so as to prevent very low energy electrons from leaving the surfaces of the accelerator electrodes and subsequently picking up energy from the surrounding electric field. In various applications, this magnetic insulation must only produce modest gains in voltage holding capability to represent a significant achievement.

  5. A TE-mode accelerator

    NASA Astrophysics Data System (ADS)

    Takeuchi, S.; Sakai, K.; Matsumoto, M.; Sugihara, R.

    1987-04-01

    An accelerator is proposed in which a TE-mode wave is used to drive charged particles in contrast to the usual linear accelerators in which longitudinal electric fields or TM-mode waves are supposed to be utilized. The principle of the acceleration is based on the V(p) x B acceleration of a dynamo force acceleration, in which a charged particle trapped in a transverse wave feels a constant electric field (Faraday induction field) and subsequently is accelerated when an appropriate magnetic field is externally applied in the direction perpendicular to the wave propagation. A pair of dielectric plates is used to produce a slow TE mode. The conditions of the particle trapping the stabilization of the particle orbit are discussed.

  6. Uniformly accelerated black holes

    NASA Astrophysics Data System (ADS)

    Letelier, Patricio S.; Oliveira, Samuel R.

    2001-09-01

    The static and stationary C metric are examined in a generic framework and their interpretations studied in some detail, especially those with two event horizons, one for the black hole and another for the acceleration. We find that (i) the spacetime of an accelerated static black hole is plagued by either conical singularities or a lack of smoothness and compactness of the black hole horizon, (ii) by using standard black hole thermodynamics we show that accelerated black holes have a higher Hawking temperature than Unruh temperature of the accelerated frame, and (iii) the usual upper bound on the product of the mass and acceleration parameters (<1/27) is just a coordinate artifact. The main results are extended to accelerated rotating black holes with no significant changes.

  7. Accelerated Reader.

    ERIC Educational Resources Information Center

    Education Commission of the States, Denver, CO.

    This paper provides an overview of Accelerated Reader, a system of computerized testing and record-keeping that supplements the regular classroom reading program. Accelerated Reader's primary goal is to increase literature-based reading practice. The program offers a computer-aided reading comprehension and management program intended to motivate…

  8. Linear accelerator: a reproducible, efficacious and cost effective alternative for blood irradiation.

    PubMed

    Shastry, Shamee; Ramya, B; Ninan, Jefy; Srinidhi, G C; Bhat, Sudha S; Fernandes, Donald J

    2013-12-01

    The dedicated devices for blood irradiation are available only at a few centers in developing countries thus the irradiation remains a service with limited availability due to prohibitive cost. To implement a blood irradiation program at our center using linear accelerator. The study is performed detailing the specific operational and quality assurance measures employed in providing a blood component-irradiation service at tertiary care hospital. X-rays generated from linear accelerator were used to irradiate the blood components. To facilitate and standardize the blood component irradiation, a blood irradiator box was designed and fabricated in acrylic. Using Elekta Precise Linear Accelerator, a dose of 25 Gy was delivered at the centre of the irradiation box. Standardization was done using five units of blood obtained from healthy voluntary blood donors. Each unit was divided to two parts. One aliquot was subjected to irradiation. Biochemical and hematological parameters were analyzed on various days of storage. Cost incurred was analyzed. Progressive increase in plasma hemoglobin, potassium and lactate dehydrogenase was noted in the irradiated units but all the parameters were within the acceptable range indicating the suitability of the product for transfusion. The irradiation process was completed in less than 30 min. Validation of the radiation dose done using TLD showed less than ± 3% variation. This study shows that that the blood component irradiation is within the scope of most of the hospitals in developing countries even in the absence of dedicated blood irradiators at affordable cost. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Proton and Ion Acceleration using Multi-kJ Lasers

    NASA Astrophysics Data System (ADS)

    Wilks, S. C.; Ma, T.; Kemp, A. J.; Tabak, M.; Link, A. J.; Haefner, C.; Hermann, M. R.; Mariscal, D. A.; Rubenchik, S.; Sterne, P.; Kim, J.; McGuffey, C.; Bhutwala, K.; Beg, F.; Wei, M.; Kerr, S. M.; Sentoku, Y.; Iwata, N.; Norreys, P.; Sevin, A.

    2017-10-01

    Short (<50 ps) laser pulses are capable of accelerating protons and ions from solid (or dense gas jet) targets as demonstrated by a number of laser facilities around the world in the past 20 years accelerating protons to between 1 and 100 MeV, depending on specific laser parameters. Over this time, a distinct scaling with energy has emerged that shows a trend towards increasing maximum accelerated proton (ion) energy with increasing laser energy. We consider the physical basis underlying this scaling, and use this to estimate future results when multi-kJ laser systems begin operating in this new high energy regime. In particular, we consider the effects of laser prepulse, intensity, energy, and pulse length on the number and energy of the ions, as well as target size and composition. We also discuss potential uses of these ion beams in High Energy Density Physics Experiments. This work was performed under the auspices of the U.S. Department of Energy (DOE) by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and funded by the LLNL LDRD program under tracking code 17-ERD-039.

  10. Addiction research centres and the nurturing of creativity: the Department of Alcohol, Drugs and Addiction at the National Institute for Health and Welfare in Finland: diverse problems, diverse perspectives.

    PubMed

    Hakkarainen, Pekka; Kiianmaa, Kalervo; Kuoppasalmi, Kimmo; Tigerstedt, Christoffer

    2012-10-01

    The Department of Alcohol, Drugs and Addiction started operations on 1 January 2009, when the National Institute of Public Health (KTL) and the National Research and Development Centre for Welfare and Health (STAKES) were merged. The newly formed institute, called the National Institute for Health and Welfare (THL), operates under the Finnish Ministry of Social Affairs and Health. The scope of the research and preventive work conducted in the Department covers alcohol, drugs, tobacco and gambling issues. The two main tasks of the Department are (i) to research, produce and disseminate information on alcohol and drugs, substance use, addictions and their social and health-related effects and (ii) to develop prevention and good practices with a view to counteracting the onset and development of alcohol and drug problems and the damaging effects of smoking and other addictions. The number of staff hovers at approximately 60 people. The Department is organized into three units, one specialized in social sciences (the Alcohol and Drug Research Unit), another in laboratory analytics (the Alcohol and Drug Analytics Unit) and the third primarily in preventive work (the Addiction Prevention Unit). These units incorporate a rich variety and long traditions of both research and preventive work. The mixture of different disciplines creates good opportunities for interdisciplinary research projects and collaboration within the Department. Also, the fact that in the same administrative context there are both researchers and people specialized in preventive work opens up interesting possibilities for combining efforts from these two branches. Nationally, the Department is a key player in all its fields of interest. It engages in a great deal of cooperation both nationally and internationally, and among its strengths are the high-quality, regularly collected long-term data sets. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  11. The Albanian National Question and the Myth of Greater Albania

    DTIC Science & Technology

    2013-03-01

    This manuscript is submitted in partial fulfillment of the requirements of the Master of Strategic Studies Degree. The views expressed in this student ...accrediting agency recognized by the U.S. Secretary of Education and the Council for Higher Education Accreditation. The views expressed in this student ...school students , conducted by the Greek National Centre of Social Research, who were asked to rank nations according to their preferences showed

  12. Anatomy of ridge discontinuities, transform fault and overlapping spreading centre, at the slow spreading sedimented Andaman Sea Spreading Centre

    NASA Astrophysics Data System (ADS)

    Jourdain, A.; Singh, S. C.; Klinger, Y.

    2013-12-01

    Transform faults are the major discontinuities and define the main segment boundaries along spreading centres but their anatomy is poorly understood because of their complex seafloor morphology, even though they are observed at all types of spreading centres. Here, we present high-resolution seismic reflection images across the sedimented Andaman Sea Transform Fault where the sediments record the faulting and allow studying the evolution of the transform fault both in space and time. Furthermore, sediments allow the imaging of the faults down to the Moho depth that provides insight on the interplay between tectonic and magmatic processes. On the other hand, overlapping spreading centres (OSC) are small-scale discontinuities, possibly transient, and are observed only along fast or intermediate spreading centres. Exceptionally, an overlapping spreading centre is present at the slow spreading Andaman Sea Spreading Centre, which, we suggest, is due to the presence of thick sediments that hamper the efficient hydrothermal circulation allowing magma to stay much longer in the crust at different depths, and up to close to the segment ends, leading to the development of an overlapping spreading. The seismic reflection images across the OSC indicate the presence of large magma bodies in the crust. Seismic images also provide images of active faults allowing to study the link between faulting and magmatism. Interestingly, an earthquake swarm occurred at propagating limb of the OSC in 2006, after the great 2004 Andaman-Sumatra earthquake of Mw=9.3, highlighting the migration of the OSC westward. In this paper, we will show seismic reflection images and interpret these images in the light of bathymetry and earthquake data, and provide the anatomy of the ridge discontinuities along the slow spreading sedimented Andaman Sea Spreading Centre.

  13. Amps particle accelerator definition study

    NASA Technical Reports Server (NTRS)

    Sellen, J. M., Jr.

    1975-01-01

    The Particle Accelerator System of the AMPS (Atmospheric, Magnetospheric, and Plasmas in Space) payload is a series of charged particle accelerators to be flown with the Space Transportation System Shuttle on Spacelab missions. In the configuration presented, the total particle accelerator system consists of an energetic electron beam, an energetic ion accelerator, and both low voltage and high voltage plasma acceleration devices. The Orbiter is illustrated with such a particle accelerator system.

  14. Radical Acceleration

    ERIC Educational Resources Information Center

    Gross, Miraca U. M.; Van Vliet, Helen E.

    2005-01-01

    Research has found that teachers' objections to accelerating gifted students are mainly based on a fear that acceleration will lead to social or emotional damage. Ironically, it is the academic and emotional maturity which characterizes intellectually gifted students, coupled with their high levels of academic achievement, which makes them such…

  15. Relativistically Induced Transparency Acceleration (RITA) - laser-plasma accelerated quasi-monoenergetic GeV ion-beams with existing lasers?

    NASA Astrophysics Data System (ADS)

    Sahai, Aakash A.

    2013-10-01

    laser's push is controlled by the electrostatic space-charge pull by the immobile background ions. In the rest-frame of the laser, the electrostatic-potential that the ions create to balance the ponderomotive force on e-s, scales as the effective vector potential, aplasma . This potential hill, due to snowplowed e-s, co-propagating with the rising laser can reflect protons and light-ions (Relativistically Induced Transparency Acceleration, RITA). Desired proton or light-ion energies can be achieved by controlling the velocity of the snowplow, which is shown to scale inversely with the rise-time of the laser (higher energies for shorter pulses) and directly with the scale-length of the plasma density gradient. Similar acceleration can be produced by controlling the increase of the laser frequency (Chirp Induced Transparency Acceleration, ChITA). Work supported by the National Science Foundation under NSF- PHY-0936278. Also, NSF-PHY-0936266 and NSF-PHY-0903039; the US Department of Energy under DEFC02-07ER41500, DE- FG02-92ER40727 and DE-FG52-09NA29552.

  16. Addiction research centres and the nurturing of creativity: The Centre for Addictions Research of British Columbia, Canada

    PubMed Central

    Stockwell, Tim; Reist, Dan; Macdonald, Scott; Benoit, Cecilia; Jansson, Mikael

    2015-01-01

    The Centre for Addictions Research of British Columbia (CARBC) was established as a multi-campus and multi-disciplinary research centre administered by the University of Victoria (UVic) in late 2003. Its core funding is provided from interest payments on an endowment of CAD$10.55 million. It is supported by a commitment to seven faculty appointments in various departments at UVic. The Centre has two offices, an administration and research office in Victoria and a knowledge exchange unit in Vancouver. The two offices are collaborating on the implementation of CARBC’s first 5-year plan which seeks to build capacity in British Columbia for integrated multi-disciplinary research and knowledge exchange in the areas substance use, addictions and harm reduction. Present challenges include losses to the endowment caused by the 2008/2009 economic crisis and difficulties negotiating faculty positions with the university administration. Despite these hurdles, to date each year has seen increased capacity for the Centre in terms of affiliated scientists, funding and staffing as well as output in terms of published reports, electronic resources and impacts on policy and practice. Areas of special research interest include: drug testing in the work-place, epidemiological monitoring, substance use and injury, pricing and taxation policies, privatization of liquor monopolies, poly-substance use, health determinants of indigenous peoples, street-involved youth and other vulnerable populations at risk of substance use problems. Further information about the Centre and its activities can be found on http://www.carbc.ca. PMID:20078479

  17. Simulations of radiation pressure ion acceleration with the VEGA Petawatt laser

    NASA Astrophysics Data System (ADS)

    Stockhausen, Luca C.; Torres, Ricardo; Conejero Jarque, Enrique

    2016-09-01

    The Spanish Pulsed Laser Centre (CLPU) is a new high-power laser facility for users. Its main system, VEGA, is a CPA Ti:Sapphire laser which, in its final phase, will be able to reach Petawatt peak powers in pulses of 30 fs with a pulse contrast of 1 :1010 at 1 ps. The extremely low level of pre-pulse intensity makes this system ideally suited for studying the laser interaction with ultrathin targets. We have used the particle-in-cell (PIC) code OSIRIS to carry out 2D simulations of the acceleration of ions from ultrathin solid targets under the unique conditions provided by VEGA, with laser intensities up to 1022 W cm-2 impinging normally on 20 - 60 nm thick overdense plasmas, with different polarizations and pre-plasma scale lengths. We show how signatures of the radiation pressure-dominated regime, such as layer compression and bunch formation, are only present with circular polarization. By passively shaping the density gradient of the plasma, we demonstrate an enhancement in peak energy up to tens of MeV and monoenergetic features. On the contrary linear polarization at the same intensity level causes the target to blow up, resulting in much lower energies and broader spectra. One limiting factor of Radiation Pressure Acceleration is the development of Rayleigh-Taylor like instabilities at the interface of the plasma and photon fluid. This results in the formation of bubbles in the spatial profile of laser-accelerated proton beams. These structures were previously evidenced both experimentally and theoretically. We have performed 2D simulations to characterize this bubble-like structure and report on the dependency on laser and target parameters.

  18. Observation of acceleration and deceleration in gigaelectron-volt-per-metre gradient dielectric wakefield accelerators

    DOE PAGES

    O’Shea, B. D.; Andonian, G.; Barber, S. K.; ...

    2016-09-14

    There is urgent need to develop new acceleration techniques capable of exceeding gigaelectron-volt-per-metre (GeV m –1) gradients in order to enable future generations of both light sources and high-energy physics experiments. To address this need, short wavelength accelerators based on wakefields, where an intense relativistic electron beam radiates the demanded fields directly into the accelerator structure or medium, are currently under intense investigation. One such wakefield based accelerator, the dielectric wakefield accelerator, uses a dielectric lined-waveguide to support a wakefield used for acceleration. Here we show gradients of 1.347±0.020 GeV m –1 using a dielectric wakefield accelerator of 15 cmmore » length, with sub-millimetre transverse aperture, by measuring changes of the kinetic state of relativistic electron beams. We follow this measurement by demonstrating accelerating gradients of 320±17 MeV m –1. As a result, both measurements improve on previous measurements by and order of magnitude and show promise for dielectric wakefield accelerators as sources of high-energy electrons.« less

  19. Observation of acceleration and deceleration in gigaelectron-volt-per-metre gradient dielectric wakefield accelerators

    PubMed Central

    O'Shea, B. D.; Andonian, G.; Barber, S. K.; Fitzmorris, K. L.; Hakimi, S.; Harrison, J.; Hoang, P. D.; Hogan, M. J.; Naranjo, B.; Williams, O. B.; Yakimenko, V.; Rosenzweig, J. B.

    2016-01-01

    There is urgent need to develop new acceleration techniques capable of exceeding gigaelectron-volt-per-metre (GeV m−1) gradients in order to enable future generations of both light sources and high-energy physics experiments. To address this need, short wavelength accelerators based on wakefields, where an intense relativistic electron beam radiates the demanded fields directly into the accelerator structure or medium, are currently under intense investigation. One such wakefield based accelerator, the dielectric wakefield accelerator, uses a dielectric lined-waveguide to support a wakefield used for acceleration. Here we show gradients of 1.347±0.020 GeV m−1 using a dielectric wakefield accelerator of 15 cm length, with sub-millimetre transverse aperture, by measuring changes of the kinetic state of relativistic electron beams. We follow this measurement by demonstrating accelerating gradients of 320±17 MeV m−1. Both measurements improve on previous measurements by and order of magnitude and show promise for dielectric wakefield accelerators as sources of high-energy electrons. PMID:27624348

  20. Delivery of antiretroviral treatment services in India: Estimated costs incurred under the National AIDS Control Programme.

    PubMed

    Agarwal, Reshu; Rewari, Bharat Bhushan; Shastri, Suresh; Nagaraja, Sharath Burugina; Rathore, Abhilakh Singh

    2017-04-01

    Competing domestic health priorities and shrinking financial support from external agencies necessitates that India's National AIDS Control Programme (NACP) brings in cost efficiencies to sustain the programme. In addition, current plans to expand the criteria for eligibility for antiretroviral therapy (ART) in India will have significant financial implications in the near future. ART centres in India provide comprehensive services to people living with HIV (PLHIV): those fulfilling national eligibility criteria and receiving ART and those on pre-ART care, i.e. not on ART. ART centres are financially supported (i) directly by the NACP; and (ii) indirectly by general health systems. This study was conducted to determine (i) the cost incurred per patient per year of pre-ART and ART services at ART centres; and (ii) the proportion of this cost incurred by the NACP and by general health systems. The study used national data from April 2013 to March 2014, on ART costs and non-ART costs (human resources, laboratory tests, training, prophylaxis and management of opportunistic infections, hospitalization, operational, and programme management). Data were extracted from procurement records and reports, statements of expenditure at national and state level, records and reports from ART centres, databases of the National AIDS Control Organisation, and reports on use of antiretroviral drugs. The analysis estimates the cost for ART services as US$ 133.89 (?8032) per patient per year, of which 66% (US$ 88.66, ?5320) is for antiretroviral drugs and 34% (US$ 45.23, ?2712) is for non-ART recurrent expenditure, while the cost for pre-ART care is US$ 33.05 (?1983) per patient per year. The low costs incurred for patients in ART and pre-ART care services can be attributed mainly to the low costs of generic drugs. However, further integration with general health systems may facilitate additional cost saving, such as in human resources.

  1. Staging of RF-accelerating Units in a MEMS-based Ion Accelerator

    NASA Astrophysics Data System (ADS)

    Persaud, A.; Seidl, P. A.; Ji, Q.; Feinberg, E.; Waldron, W. L.; Schenkel, T.; Ardanuc, S.; Vinayakumar, K. B.; Lal, A.

    Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio- frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized with acceleration gap distances and beam aperture sizes of the order of centimeters. Through advances in Micro-Electro-Mechanical Systems (MEMS) fabrication, MEQALACs can now be scaled down to the sub-millimeter regime and batch processed on wafer substrates. In this paper we show first results from using three RF stages in a compact MEMS-based ion accelerator. The results presented show proof-of-concept with accelerator structures formed from printed circuit boards using a 3 × 3 beamlet arrangement and noble gas ions at 10 keV. We present a simple model to describe the measured results. We also discuss some of the scaling behaviour of a compact MEQALAC. The MEMS-based approach enables a low-cost, highly versatile accelerator covering a wide range of currents (10 μA to 100 mA) and beam energies (100 keV to several MeV). Applications include ion-beam analysis, mass spectrometry, materials processing, and at very high beam powers, plasma heating.

  2. Staging of RF-accelerating Units in a MEMS-based Ion Accelerator

    DOE PAGES

    Persaud, A.; Seidl, P. A.; Ji, Q.; ...

    2017-10-26

    Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio- frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized with acceleration gap distances and beam aperture sizes of the order of centimeters. Through advances in Micro-Electro-Mechanical Systems (MEMS) fabrication, MEQALACs can now be scaled down to the sub-millimeter regime and batch processed on wafer substrates. In this paper we show first results from using three RF stages in a compact MEMS-based ion accelerator. The results presented show proof-of-concept with accelerator structures formed from printed circuit boards using a 3more » × 3 beamlet arrangement and noble gas ions at 10 keV. We present a simple model to describe the measured results. We also discuss some of the scaling behaviour of a compact MEQALAC. The MEMS-based approach enables a low-cost, highly versatile accelerator covering a wide range of currents (10 μA to 100 mA) and beam energies (100 keV to several MeV). Applications include ion-beam analysis, mass spectrometry, materials processing, and at very high beam powers, plasma heating.« less

  3. Staging of RF-accelerating Units in a MEMS-based Ion Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Persaud, A.; Seidl, P. A.; Ji, Q.

    Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio- frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized with acceleration gap distances and beam aperture sizes of the order of centimeters. Through advances in Micro-Electro-Mechanical Systems (MEMS) fabrication, MEQALACs can now be scaled down to the sub-millimeter regime and batch processed on wafer substrates. In this paper we show first results from using three RF stages in a compact MEMS-based ion accelerator. The results presented show proof-of-concept with accelerator structures formed from printed circuit boards using a 3more » × 3 beamlet arrangement and noble gas ions at 10 keV. We present a simple model to describe the measured results. We also discuss some of the scaling behaviour of a compact MEQALAC. The MEMS-based approach enables a low-cost, highly versatile accelerator covering a wide range of currents (10 μA to 100 mA) and beam energies (100 keV to several MeV). Applications include ion-beam analysis, mass spectrometry, materials processing, and at very high beam powers, plasma heating.« less

  4. Taking Down a Giant: 699 Tons of SLAC’s Accelerator Removed for Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2017-01-31

    For the first time in more than 50 years, a door opened at the western end of the historic linear accelerator at the Department of Energy’s SLAC National Accelerator Laboratory casts light on four empty walls stretching as far as the eye can see. This end of the linac – a full kilometer of it – has been stripped of all its equipment both above and below ground. Over the next two years it will be re-equipped with new technology to power another wonder of modern science: an X-ray laser that will fire a million pulses per second.

  5. Measurement of Impact Acceleration: Mouthpiece Accelerometer Versus Helmet Accelerometer

    PubMed Central

    Higgins, Michael; Halstead, P. David; Snyder-Mackler, Lynn; Barlow, David

    2007-01-01

    Context: Instrumented helmets have been used to estimate impact acceleration imparted to the head during helmet impacts. These instrumented helmets may not accurately measure the actual amount of acceleration experienced by the head due to factors such as helmet-to-head fit. Objective: To determine if an accelerometer attached to a mouthpiece (MP) provides a more accurate representation of headform center of gravity (HFCOG) acceleration during impact than does an accelerometer attached to a helmet fitted on the headform. Design: Single-factor research design in which the independent variable was accelerometer position (HFCOG, helmet, MP) and the dependent variables were g and Severity Index (SI). Setting: Independent impact research laboratory. Intervention(s): The helmeted headform was dropped (n = 168) using a National Operating Committee on Standards for Athletic Equipment (NOCSAE) drop system from the standard heights and impact sites according to NOCSAE test standards. Peak g and SI were measured for each accelerometer position during impact. Main Outcome Measures: Upon impact, the peak g and SI were recorded for each accelerometer location. Results: Strong relationships were noted for HFCOG and MP measures, and significant differences were seen between HFCOG and helmet g measures and HFCOG and helmet SI measures. No statistically significant differences were noted between HFCOG and MP g and SI measures. Regression analyses showed a significant relationship between HFCOG and MP measures but not between HFCOG and helmet measures. Conclusions: Upon impact, MP acceleration (g) and SI measurements were closely related to and more accurate in measuring HFCOG g and SI than helmet measurements. The MP accelerometer is a valid method for measuring head acceleration. PMID:17597937

  6. Proposal for an Accelerator R&D User Facility at Fermilab's Advanced Superconducting Test Accelerator (ASTA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Church, M.; Edwards, H.; Harms, E.

    2013-10-01

    Fermilab is the nation’s particle physics laboratory, supported by the DOE Office of High Energy Physics (OHEP). Fermilab is a world leader in accelerators, with a demonstrated track-record— spanning four decades—of excellence in accelerator science and technology. We describe the significant opportunity to complete, in a highly leveraged manner, a unique accelerator research facility that supports the broad strategic goals in accelerator science and technology within the OHEP. While the US accelerator-based HEP program is oriented toward the Intensity Frontier, which requires modern superconducting linear accelerators and advanced highintensity storage rings, there are no accelerator test facilities that support themore » accelerator science of the Intensity Frontier. Further, nearly all proposed future accelerators for Discovery Science will rely on superconducting radiofrequency (SRF) acceleration, yet there are no dedicated test facilities to study SRF capabilities for beam acceleration and manipulation in prototypic conditions. Finally, there are a wide range of experiments and research programs beyond particle physics that require the unique beam parameters that will only be available at Fermilab’s Advanced Superconducting Test Accelerator (ASTA). To address these needs we submit this proposal for an Accelerator R&D User Facility at ASTA. The ASTA program is based on the capability provided by an SRF linac (which provides electron beams from 50 MeV to nearly 1 GeV) and a small storage ring (with the ability to store either electrons or protons) to enable a broad range of beam-based experiments to study fundamental limitations to beam intensity and to develop transformative approaches to particle-beam generation, acceleration and manipulation which cannot be done elsewhere. It will also establish a unique resource for R&D towards Energy Frontier facilities and a test-bed for SRF accelerators and high brightness beam applications in support of the

  7. Diffusive shock acceleration - Acceleration rate, magnetic-field direction and the diffusion limit

    NASA Technical Reports Server (NTRS)

    Jokipii, J. R.

    1992-01-01

    This paper reviews the concept of diffusive shock acceleration, showing that the acceleration of charged particles at a collisionless shock is a straightforward consequence of the standard cosmic-ray transport equation, provided that one treats the discontinuity at the shock correctly. This is true for arbitrary direction of the upstream magnetic field. Within this framework, it is shown that acceleration at perpendicular or quasi-perpendicular shocks is generally much faster than for parallel shocks. Paradoxically, it follows also that, for a simple scattering law, the acceleration is faster for less scattering or larger mean free path. Obviously, the mean free path can not become too large or the diffusion limit becomes inapplicable. Gradient and curvature drifts caused by the magnetic-field change at the shock play a major role in the acceleration process in most cases. Recent observations of the charge state of the anomalous component are shown to require the faster acceleration at the quasi-perpendicular solar-wind termination shock.

  8. Energy efficiency in U.K. shopping centres

    NASA Astrophysics Data System (ADS)

    Mangiarotti, Michela

    Energy efficiency in shopping centres means providing comfortable internal environment and services to the occupants with minimum energy use in a cost-effective and environmentally sensitive manner. This research considers the interaction of three factors affecting the energy efficiency of shopping centres: i) performance of the building fabric and services ii) management of the building in terms of operation, control, maintenance and replacement of the building fabric and services, and company's energy policy iii) occupants' expectation for comfort and awareness of energy efficiency. The aim of the investigation is to determine the role of the above factors in the energy consumption and carbon emissions of shopping centres and the scope for reducing this energy usage by changing one or all the three factors. The study also attempts to prioritize the changes in the above factors that are more cost-effective at reducing that energy consumption and identify the benefits and main economic and legal drivers for energy efficiency in shopping centres. To achieve these targets, three case studies have been analysed. Using energy data from bills, the performance of the selected case studies has been assessed to establish trends and current energy consumption and carbon emissions of shopping centres and their related causes. A regression analysis has attempted to break down the energy consumption of the landlords' area by end-use to identify the main sources of energy usage and consequently introduce cost-effective measures for saving energy. A monitoring and occupants' survey in both landlords' and tenants' areas have been carried out at the same time to compare the objective data of the environmental conditions with the subjective impressions of shoppers and shopkeepers. In particular, the monitoring aimed at assessing the internal environment to identify possible causes of discomfort and opportunities for introducing energy saving measures. The survey looked at

  9. Non-gravitational acceleration in the trajectory of 1I/2017 U1 ('Oumuamua).

    PubMed

    Micheli, Marco; Farnocchia, Davide; Meech, Karen J; Buie, Marc W; Hainaut, Olivier R; Prialnik, Dina; Schörghofer, Norbert; Weaver, Harold A; Chodas, Paul W; Kleyna, Jan T; Weryk, Robert; Wainscoat, Richard J; Ebeling, Harald; Keane, Jacqueline V; Chambers, Kenneth C; Koschny, Detlef; Petropoulos, Anastassios E

    2018-06-27

    'Oumuamua (1I/2017 U1) is the first known object of interstellar origin to have entered the Solar System on an unbound and hyperbolic trajectory with respect to the Sun 1 . Various physical observations collected during its visit to the Solar System showed that it has an unusually elongated shape and a tumbling rotation state 1-4 and that the physical properties of its surface resemble those of cometary nuclei 5,6 , even though it showed no evidence of cometary activity 1,5,7 . The motion of all celestial bodies is governed mostly by gravity, but the trajectories of comets can also be affected by non-gravitational forces due to cometary outgassing 8 . Because non-gravitational accelerations are at least three to four orders of magnitude weaker than gravitational acceleration, the detection of any deviation from a purely gravity-driven trajectory requires high-quality astrometry over a long arc. As a result, non-gravitational effects have been measured on only a limited subset of the small-body population 9 . Here we report the detection, at 30σ significance, of non-gravitational acceleration in the motion of 'Oumuamua. We analyse imaging data from extensive observations by ground-based and orbiting facilities. This analysis rules out systematic biases and shows that all astrometric data can be described once a non-gravitational component representing a heliocentric radial acceleration proportional to r -2 or r -1 (where r is the heliocentric distance) is included in the model. After ruling out solar-radiation pressure, drag- and friction-like forces, interaction with solar wind for a highly magnetized object, and geometric effects originating from 'Oumuamua potentially being composed of several spatially separated bodies or having a pronounced offset between its photocentre and centre of mass, we find comet-like outgassing to be a physically viable explanation, provided that 'Oumuamua has thermal properties similar to comets.

  10. SPOT4 Management Centre

    NASA Technical Reports Server (NTRS)

    Labrune, Yves; Labbe, X.; Roussel, A.; Vielcanet, P.

    1994-01-01

    In the context of the CNES SPOT4 program CISI is particularly responsible for the development of the SPOT4 Management Centre, part of the SPOT4 ground control system located at CNES Toulouse (France) designed to provide simultaneous control over two satellites. The main operational activities are timed to synchronize with satellite visibilities (ten usable passes per day). The automatic capability of this system is achieved through agenda services (sequence of operations as defined and planned by operator). Therefore, the SPOT4 Management Centre offers limited, efficient and secure human interventions for supervision and decision making. This paper emphasizes the main system characteristics as degree of automation, level of dependability and system parameterization.

  11. The British society for gynaecological endoscopy endometriosis centres project.

    PubMed

    Saridogan, Ertan; Byrne, Dominic

    2013-01-01

    Management of advanced endometriosis frequently requires a multidisciplinary team approach and international guidelines suggest treatment in centres of expertise. Due to variability of published outcome data, prospective data collection and standardisation of reporting systems have been suggested to improve our understanding of surgical outcomes. The British Society for Gynaecological Endoscopy (BSGE) Endometriosis Centres were established to manage rectovaginal endometriosis, to collect treatment and outcome data, and to provide these data to patients, clinicians and healthcare commissioners. The BSGE Endometriosis Centres Project works on the principle of voluntary participation. Centres that would like to be recognised or accredited as a BSGE Endometriosis Centre need to fulfil a number of basic requirements including working in appropriate multidisciplinary clinical teams, auditing their outcome and having sufficient workload to maintain their surgical skills. The project has already had an impact on where the patients with advanced endometriosis are treated in the United Kingdom. Patients and healthcare professionals are becoming aware of their presence and more patients with the condition are being referred to these centres. It is also expected that the accredited centre status would be required for funding by healthcare commissioners for this type endometriosis. Copyright © 2013 S. Karger AG, Basel.

  12. Taiwanese maternal health in the postpartum nursing centre.

    PubMed

    Hung, Chich-Hsiu; Yu, Ching-Yun; Ou, Chu-Chun; Liang, Wei-Wen

    2010-04-01

    To investigate the association between postpartum stress as well as social support and the general health status of women recently discharged from postpartum nursing centres where the ritual of Tso-Yueh-Tzu is followed. Taiwanese women stay in postpartum nursing centres to take care of their newborn babies and perform the traditional Chinese ritual of Tso-Yueh-Tzu, the custom of a postpartum month-long rest. A non-experimental research design was used in the study. Two hundred and fifty-eight postpartum women who had stayed in postpartum nursing centres for at least 20 days were recruited at eight postpartum nursing centres in the Kaohsiung metropolitan area of southern Taiwan. They were administered the Hung Postpartum Stress Scale, the Social Support Scale and the Chinese Health Questionnaire. Women without minor psychiatric morbidity had higher social support, lower postpartum stress and longer length-of-stays in the postpartum care centre than women with minor psychiatric morbidity. Postpartum stress revolved around changes in body shape. A one-point increase in postpartum stress increased the likelihood that a mother would suffer minor psychiatric morbidity by 1.04 times; while giving birth to a boy decreased that likelihood by 0.51 times. This study found Tso-Yueh-Tzu as practised in postpartum nursing centres gave the postpartum women the opportunity to receive tangible support and, therefore, helped decrease postpartum stress and improved their general health. The greatest source of postpartum stress was concern over negative body changes. The postpartum nursing centre plays an important role in helping postpartum Taiwanese women observe the traditional ritual of Tso-Yueh-Tzu and in improving these women's general health. These centres may want to pay more attention to providing exercise that promotes body toning and relaxation.

  13. Cosmic Ray Acceleration from Multiple Galactic Wind Shocks

    NASA Astrophysics Data System (ADS)

    Cotter, Cory; Bustard, Chad; Zweibel, Ellen

    2018-01-01

    Cosmic rays still have an unknown origin. Many mechanisms have been suggested for their acceleration including quasars, pulsars, magnetars, supernovae, supernova remnants, and galactic termination shocks. The source of acceleration may be a mixture of these and a different mixture in different energy regimes. Using numerical simulations, we investigate multiple shocks in galactic winds as potential cosmic rays sources. By having shocks closer to the parent galaxy, more particles may diffuse back to the disk instead of being blown out in the wind, as found in Bustard, Zweibel, and Cotter (2017, ApJ) and also Merten, Bustard, Zweibel, and Tjus (to be submitted to ApJ). Specifically, this flux of cosmic rays could contribute to the unexplained "shin" region between the well-known "knee" and "ankle" of the cosmic ray spectrum. We would like to acknowledge support from the National Science Foundation (NSF) Graduate Research Fellowship Program under grant No. DGE-125625 and NSF grant No. AST-1616037.

  14. Electron Beam Charge Diagnostics for Laser Plasma Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, Kei; Gonsalves, Anthony; Lin, Chen

    2011-06-27

    A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/(ps mm{sup 2}), respectively. After the radio-frequency accelerator based cross calibration, amore » series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within {+-}8%, showing that they all can provide accurate charge measurements for LPAs.« less

  15. Plasma Wakefield Acceleration and FACET - Facilities for Accelerator Science and Experimental Test Beams at SLAC

    ScienceCinema

    Seryi, Andrei

    2017-12-22

    Plasma wakefield acceleration is one of the most promising approaches to advancing accelerator technology. This approach offers a potential 1,000-fold or more increase in acceleration over a given distance, compared to existing accelerators.  FACET, enabled by the Recovery Act funds, will study plasma acceleration, using short, intense pulses of electrons and positrons. In this lecture, the physics of plasma acceleration and features of FACET will be presented.  

  16. Dosimetric inter-institutional comparison in European radiotherapy centres: Results of IAEA supported treatment planning system audit.

    PubMed

    Gershkevitsh, Eduard; Pesznyak, Csilla; Petrovic, Borislava; Grezdo, Joseph; Chelminski, Krzysztof; do Carmo Lopes, Maria; Izewska, Joanna; Van Dyk, Jacob

    2014-05-01

    One of the newer audit modalities operated by the International Atomic Energy Agency (IAEA) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried out in eight European countries - Estonia, Hungary, Latvia, Lithuania, Serbia, Slovakia, Poland and Portugal. The corresponding results are presented. The TPS audit reviews the dosimetry, treatment planning and radiotherapy delivery processes using the 'end-to-end' approach, i.e. following the pathway similar to that of the patient, through imaging, treatment planning and dose delivery. The audit is implemented at the national level with IAEA assistance. The national counterparts conduct the TPS audit at local radiotherapy centres through on-site visits. TPS calculated doses are compared with ion chamber measurements performed in an anthropomorphic phantom for eight test cases per algorithm/beam. A set of pre-defined agreement criteria is used to analyse the performance of TPSs. TPS audit was carried out in 60 radiotherapy centres. In total, 190 data sets (combination of algorithm and beam quality) have been collected and reviewed. Dosimetry problems requiring interventions were discovered in about 10% of datasets. In addition, suboptimal beam modelling in TPSs was discovered in a number of cases. The TPS audit project using the IAEA methodology has verified the treatment planning system calculations for 3D conformal radiotherapy in a group of radiotherapy centres in Europe. It contributed to achieving better understanding of the performance of TPSs and helped to resolve issues related to imaging, dosimetry and treatment planning.

  17. Causes of death in hospitalised HIV-infected patients at a National Referral Centre in Singapore: a retrospective review from 2008 to 2010.

    PubMed

    Wong, Chen Seong; Lo, Francis A; Cavailler, Philippe; Ng, Oon Tek; Lee, Cheng Chuan; Leo, Yee Sin; Chua, Arlene C

    2012-12-01

    Highly active antiretroviral therapy (HAART) has improved outcomes for individuals infected with human immunodeficiency virus (HIV). This study describes the causes of death in hospitalised HIV-positive patients from 2008 to 2010 in Tan Tock Seng Hospital, the national referral centre for HIV management in Singapore. Data were retrospectively collected from HIV-positive patients who died in Tan Tock Seng Hospital from January 2008 to December 2010. Sixty-seven deaths occurred in the study period. A majority of patients died of non-acquired immune deficiency syndrome (AIDS)-defining illnesses (54.7%). The median CD4 count was 39.5 (range, 20.0 to 97.0), and 7 patients had HIV viral loads of <200 copies/mL. There were 27 deaths due to opportunistic infections, 27 due to non AIDS-defining infections, 4 due to non AIDS-associated malignancies. This study also describes 3 deaths due to cardiovascular events, and 1 due to hepatic failure. Patients who had virologic suppression were more likely to die from non AIDS-defining causes. Causes of death in HIV-positive patients have changed in the HAART era. More research is required to further understand and address barriers to testing and treatment to further improve outcomes in HIV/AIDS.

  18. Critiquing Child-Centred Pedagogy to Bring Children and Early Childhood Educators into the Centre of a Democratic Pedagogy

    ERIC Educational Resources Information Center

    Langford, Rachel

    2010-01-01

    Child-centred pedagogy is both an enduring approach and a revered concept in Western-based teacher preparation. This article weaves together major critiques of child-centred pedagogy that draw on critical feminist, postmodernist and post-structural theories. These critiques have particular relevance for conceptualizing what it can mean to be, and…

  19. Electron beam accelerator with magnetic pulse compression and accelerator switching

    DOEpatents

    Birx, Daniel L.; Reginato, Louis L.

    1988-01-01

    An electron beam accelerator comprising an electron beam generator-injector to produce a focused beam of .gtoreq.0.1 MeV energy electrons; a plurality of substantially identical, aligned accelerator modules to sequentially receive and increase the kinetic energies of the beam electrons by about 0.1-1 MeV per module. Each accelerator module includes a pulse-forming network that delivers a voltage pulse to the module of substantially .gtoreq.0.1-1 MeV maximum energy over a time duration of .ltoreq.1 .mu.sec.

  20. Electron beam accelerator with magnetic pulse compression and accelerator switching

    DOEpatents

    Birx, Daniel L.; Reginato, Louis L.

    1987-01-01

    An electron beam accelerator comprising an electron beam generator-injector to produce a focused beam of .gtoreq.0.1 MeV energy electrons; a plurality of substantially identical, aligned accelerator modules to sequentially receive and increase the kinetic energies of the beam electrons by about 0.1-1 MeV per module. Each accelerator module includes a pulse-forming network that delivers a voltage pulse to the module of substantially 0.1-1 MeV maximum energy over a time duration of .ltoreq.1 .mu.sec.

  1. Are all metal-on-metal hip revision operations contributing to the National Joint Registry implant survival curves? : a study comparing the London Implant Retrieval Centre and National Joint Registry datasets.

    PubMed

    Sabah, S A; Henckel, J; Koutsouris, S; Rajani, R; Hothi, H; Skinner, J A; Hart, A J

    2016-01-01

    The National Joint Registry for England, Wales and Northern Ireland (NJR) has extended its scope to report on hospital, surgeon and implant performance. Data linkage of the NJR to the London Implant Retrieval Centre (LIRC) has previously evaluated data quality for hip primary procedures, but did not assess revision records. We analysed metal-on-metal hip revision procedures performed between 2003 and 2013. A total of 69 929 revision procedures from the NJR and 929 revised pairs of components from the LIRC were included. We were able to link 716 (77.1%) revision procedures on the NJR to the LIRC. This meant that 213 (22.9%) revision procedures at the LIRC could not be identified on the NJR. We found that 349 (37.6%) explants at the LIRC completed the full linkage process to both NJR primary and revision databases. Data completion was excellent (> 99.9%) for revision procedures reported to the NJR. This study has shown that only approximately one third of retrieved components at the LIRC, contributed to survival curves on the NJR. We recommend prospective registry-retrieval linkage as a tool to feedback missing and erroneous data to the NJR and improve data quality. Prospective Registry - retrieval linkage is a simple tool to evaluate and improve data quality on the NJR. ©2016 Sabah et al.

  2. Reducing cooling energy consumption in data centres and critical facilities

    NASA Astrophysics Data System (ADS)

    Cross, Gareth

    Given the rise of our everyday reliance on computers in all walks of life, from checking the train times to paying our credit card bills online, the need for computational power is ever increasing. Other than the ever-increasing performance of home Personal Computers (PC's) this reliance has given rise to a new phenomenon in the last 10 years ago. The data centre. Data centres contain vast arrays of IT cabinets loaded with servers that perform millions of computational equations every second. It is these data centres that allow us to continue with our reliance on the internet and the PC. As more and more data centres become necessary due to the increase in computing processing power required for the everyday activities we all take for granted so the energy consumed by these data centres rises. Not only are more and more data centres being constructed daily, but operators are also looking at ways to squeeze more processing from their existing data centres. This in turn leads to greater heat outputs and therefore requires more cooling. Cooling data centres requires a sizeable energy input, indeed to many megawatts per data centre site. Given the large amounts of money dependant on the successful operation of data centres, in particular for data centres operated by financial institutions, the onus is predominantly on ensuring the data centres operate with no technical glitches rather than in an energy conscious fashion. This report aims to investigate the ways and means of reducing energy consumption within data centres without compromising the technology the data centres are designed to house. As well as discussing the individual merits of the technologies and their implementation technical calculations will be undertaken where necessary to determine the levels of energy saving, if any, from each proposal. To enable comparison between each proposal any design calculations within this report will be undertaken against a notional data facility. This data facility will

  3. Behind the Scenes of the Spallation Neutron Source – The Linear Accelerator

    ScienceCinema

    Galambos, John

    2018-06-25

    The Spallation Neutron Source at Oak Ridge National Laboratory is a one-of-a-kind research facility that provides the most intense pulsed neutron beams in the world for scientific research and industrial development. Take a look inside the facility's linear accelerator.

  4. India Solar Resource Data: Enhanced Data for Accelerated Deployment (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Identifying potential locations for solar photovoltaic (PV) and concentrating solar power (CSP) projects requires an understanding of the underlying solar resource. Under a bilateral partnership between the United States and India - the U.S.-India Energy Dialogue - the National Renewable Energy Laboratory has updated Indian solar data and maps using data provided by the Ministry of New and Renewable Energy (MNRE) and the National Institute for Solar Energy (NISE). This fact sheet overviews the updated maps and data, which help identify high-quality solar energy projects. This can help accelerate the deployment of solar energy in India.

  5. Experimental, Theoretical and Computational Studies of Plasma-Based Concepts for Future High Energy Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, Chan; Mori, W.

    2013-10-21

    This is the final report on the DOE grant number DE-FG02-92ER40727 titled, “Experimental, Theoretical and Computational Studies of Plasma-Based Concepts for Future High Energy Accelerators.” During this grant period the UCLA program on Advanced Plasma Based Accelerators, headed by Professor C. Joshi has made many key scientific advances and trained a generation of students, many of whom have stayed in this research field and even started research programs of their own. In this final report however, we will focus on the last three years of the grant and report on the scientific progress made in each of the four tasksmore » listed under this grant. Four tasks are focused on: Plasma Wakefield Accelerator Research at FACET, SLAC National Accelerator Laboratory, In House Research at UCLA’s Neptune and 20 TW Laser Laboratories, Laser-Wakefield Acceleration (LWFA) in Self Guided Regime: Experiments at the Callisto Laser at LLNL, and Theory and Simulations. Major scientific results have been obtained in each of the four tasks described in this report. These have led to publications in the prestigious scientific journals, graduation and continued training of high quality Ph.D. level students and have kept the U.S. at the forefront of plasma-based accelerators research field.« less

  6. The value of testing multiple anatomic sites for gonorrhoea and chlamydia in sexually transmitted infection centres in the Netherlands, 2006-2010.

    PubMed

    Koedijk, F D H; van Bergen, J E A M; Dukers-Muijrers, N H T M; van Leeuwen, A P; Hoebe, C J P A; van der Sande, M A B

    2012-09-01

    National surveillance data from 2006 to 2010 of the Dutch sexually transmitted infection (STI) centres were used to analyse current practices on testing extragenital sites for chlamydia and gonorrhoea in men who have sex with men (MSM) and women. In MSM, 76.0% and 88.9% were tested at least at one extragenital site (pharyngeal and/or anorectal) for chlamydia and gonorrhoea, respectively; for women this was 20.5% and 30.2%. Testing more than one anatomic site differed by STI centre, ranging from 2% to 100%. In MSM tested at multiple sites, 63.0% and 66.5% of chlamydia and gonorrhoea diagnoses, respectively, would have been missed if screened at the urogenital site only, mainly anorectal infections. For women tested at multiple sites, the proportions of missed chlamydia and gonorrhoea diagnoses would have been 12.9% and 30.0%, respectively. Testing extragenital sites appears warranted, due to the numerous infections that would have been missed. Adding anorectal screening to urogenital screening for all MSM visiting an STI centre should be recommended. Since actual testing practices differ by centre, there is a need for clearer guidelines. Routine gonorrhoea and chlamydia screening at multiple sites in STI centres should be investigated further as this might be a more effective approach to reduce transmission than current practice.

  7. Particle acceleration

    NASA Technical Reports Server (NTRS)

    Vlahos, L.; Machado, M. E.; Ramaty, R.; Murphy, R. J.; Alissandrakis, C.; Bai, T.; Batchelor, D.; Benz, A. O.; Chupp, E.; Ellison, D.

    1986-01-01

    Data is compiled from Solar Maximum Mission and Hinothori satellites, particle detectors in several satellites, ground based instruments, and balloon flights in order to answer fundamental questions relating to: (1) the requirements for the coronal magnetic field structure in the vicinity of the energization source; (2) the height (above the photosphere) of the energization source; (3) the time of energization; (4) transistion between coronal heating and flares; (5) evidence for purely thermal, purely nonthermal and hybrid type flares; (6) the time characteristics of the energization source; (7) whether every flare accelerates protons; (8) the location of the interaction site of the ions and relativistic electrons; (9) the energy spectra for ions and relativistic electrons; (10) the relationship between particles at the Sun and interplanetary space; (11) evidence for more than one acceleration mechanism; (12) whether there is single mechanism that will accelerate particles to all energies and also heat the plasma; and (13) how fast the existing mechanisms accelerate electrons up to several MeV and ions to 1 GeV.

  8. ACCELERATION INTEGRATOR

    DOEpatents

    Pope, K.E.

    1958-01-01

    This patent relates to an improved acceleration integrator and more particularly to apparatus of this nature which is gyrostabilized. The device may be used to sense the attainment by an airborne vehicle of a predetermined velocitv or distance along a given vector path. In its broad aspects, the acceleration integrator utilizes a magnetized element rotatable driven by a synchronous motor and having a cylin drical flux gap and a restrained eddy- current drag cap deposed to move into the gap. The angular velocity imparted to the rotatable cap shaft is transmitted in a positive manner to the magnetized element through a servo feedback loop. The resultant angular velocity of tae cap is proportional to the acceleration of the housing in this manner and means may be used to measure the velocity and operate switches at a pre-set magnitude. To make the above-described dcvice sensitive to acceleration in only one direction the magnetized element forms the spinning inertia element of a free gyroscope, and the outer housing functions as a gimbal of a gyroscope.

  9. Joint kinematics and kinetics of overground accelerated running versus running on an accelerated treadmill

    PubMed Central

    Van Caekenberghe, Ine; Segers, Veerle; Aerts, Peter; Willems, Patrick; De Clercq, Dirk

    2013-01-01

    Literature shows that running on an accelerated motorized treadmill is mechanically different from accelerated running overground. Overground, the subject has to enlarge the net anterior–posterior force impulse proportional to acceleration in order to overcome linear whole body inertia, whereas on a treadmill, this force impulse remains zero, regardless of belt acceleration. Therefore, it can be expected that changes in kinematics and joint kinetics of the human body also are proportional to acceleration overground, whereas no changes according to belt acceleration are expected on a treadmill. This study documents kinematics and joint kinetics of accelerated running overground and running on an accelerated motorized treadmill belt for 10 young healthy subjects. When accelerating overground, ground reaction forces are characterized by less braking and more propulsion, generating a more forward-oriented ground reaction force vector and a more forwardly inclined body compared with steady-state running. This change in body orientation as such is partly responsible for the changed force direction. Besides this, more pronounced hip and knee flexion at initial contact, a larger hip extension velocity, smaller knee flexion velocity and smaller initial plantarflexion velocity are associated with less braking. A larger knee extension and plantarflexion velocity result in larger propulsion. Altogether, during stance, joint moments are not significantly influenced by acceleration overground. Therefore, we suggest that the overall behaviour of the musculoskeletal system (in terms of kinematics and joint moments) during acceleration at a certain speed remains essentially identical to steady-state running at the same speed, yet acting in a different orientation. However, because acceleration implies extra mechanical work to increase the running speed, muscular effort done (in terms of power output) must be larger. This is confirmed by larger joint power generation at the level

  10. How children's rights are constructed in family-centred care: a review of the literature.

    PubMed

    Kelly, Margaret; Jones, Susan; Wilson, Val; Lewis, Peter

    2012-06-01

    It appears that the acceptance of children's rights within the acute care setting is treated as a given but such a given requires a more systematic analysis. This has been undertaken here in the form of a review of the literature. The purpose of the review is to explore how children's rights, defined by the United Nations Convention on the Rights of the Child (UNCRC) are recognized in family-centred care in the acute care paediatric setting as reported in the literature. Reports that were available from 1989 to 2010 were reviewed. Children's rights are not mentioned frequently in the literature of interest to children's nurses. What is revealed are the ethical tensions in the challenge to act at all times in children's best interests (in the spirit of Article 3) while giving due weight to their views (in the spirit of Article 12) (OHCHR, 1989). The continuing failure to address these tensions undermines the spirit and practice of family-centred care.

  11. Need and feasibility of telemedicine in non-urban day care centres.

    PubMed

    Setia, Monika; DelliFraine, Jami L

    2010-01-01

    There appear to have been no studies of telemedicine in rural day care centres. We have assessed the feasibility of using telemedicine in eight rural day care centres in Pennsylvania, from the day care centres' perspective. The average number of children in these centres was 76 (range 20-150). The centres sent an average of 4.7 children home each month because of illness. Using telephone and face-to-face interviews, we assessed their perceived need for and familiarity with telemedicine, as well as their openness and preparedness for implementing telemedicine. Most day care centres reported a need for telemedicine and were open to learning how to use it. Some centres were concerned about adequate space for the equipment, but overall, the centres felt that their resources were adequate. Telemedicine in rural day care centres appears to be feasible, and would have the potential to save time and money for parents, as well as perhaps improving health care for children in rural areas.

  12. The WMO RA VI Regional Climate Centre Network - a support to users in Europe

    NASA Astrophysics Data System (ADS)

    Rösner, S.

    2012-04-01

    Climate, like weather, has no limits. Therefore the World Meteorological Organization (WMO), a specialized United Nations organization, has established a three-level infrastructure to better serve its member countries. This structure comprises Global Producing Centres for Long-range Forecasts (GPCs), Regional Climate Centres (RCCs) and National Meteorological or Hydrometeorological Services (NMHSs), in most cases representing their countries in WMO governance bodies. The elements of this infrastructure are also part of and contribute to the Global Framework for Climate Services (GFCS) agreed to be established by World Climate Conference 3 (WCC-3) and last year's Sixteenth World Meteorological Congress (WMO Cg-XVI). RCCs are the core element of this infrastructure at the regional level and are being establish in all WMO Regional Associations (RAs), i.e. Africa (RA I); Asia (II); South America (III); North America, Central America and the Caribbean (IV); South-West Pacific (V); Europe (VI). Addressing inter-regional areas of common interest like the Mediterranean or the Polar Regions may require inter-regional RCCs. For each region the RCCs follow a user driven approach with regard to governance and structure as well as products generated for the users in the respective region. However, there are common guidelines all RCCs do have to follow. This is to make sure that services are provided based on best scientific standards, are routinely and reliably generated and made available in an operational mode. These guidelines are being developed within WMO and make use of decade-long experience gained in the business of operational weather forecast. Based on the requirements of the 50 member countries of WMO RA VI it was agreed to establish the WMO RCC as a network of centres of excellence that create regional products including long-range forecasts that support regional and national climate activities, and thereby strengthen the capacity of WMO Members in the region to

  13. Electron beam accelerator with magnetic pulse compression and accelerator switching

    DOEpatents

    Birx, D.L.; Reginato, L.L.

    1984-03-22

    An electron beam accelerator is described comprising an electron beam generator-injector to produce a focused beam of greater than or equal to .1 MeV energy electrons; a plurality of substantially identical, aligned accelerator modules to sequentially receive and increase the kinetic energies of the beam electron by about .1-1 MeV per module. Each accelerator module includes a pulse-forming network that delivers a voltage pulse to the module of substantially .1-1 MeV maximum energy over a time duration of less than or equal to 1 ..mu..sec.

  14. The validity of a behavioural multiple-mini-interview within an assessment centre for selection into specialty training

    PubMed Central

    2014-01-01

    Background Entry into specialty training was determined by a National Assessment Centre (NAC) approach using a combination of a behavioural Multiple-Mini-Interview (MMI) and a written Situational Judgement Test (SJT). We wanted to know if interviewers could make reliable and valid decisions about the non-cognitive characteristics of candidates with the purpose of selecting them into general practice specialty training using the MMI. Second, we explored the concurrent validity of the MMI with the SJT. Methods A variance components analysis estimated the reliability and sources of measurement error. Further modelling estimated the optimal configurations for future MMI iterations. We calculated the relationship of the MMI with the SJT. Results Data were available from 1382 candidates, 254 interviewers, six MMI questions, five alternate forms of a 50-item SJT, and 11 assessment centres. For a single MMI question and one assessor, 28% of the variance between scores was due to candidate-to-candidate variation. Interviewer subjectivity, in particular the varying views that interviewer had for particular candidates accounted for 40% of the variance in scores. The generalisability co-efficient for a six question MMI was 0.7; to achieve 0.8 would require ten questions. A disattenuated correlation with the SJT (r = 0.35), and in particular a raw score correlation with the subdomain related to clinical knowledge (r = 0.25) demonstrated evidence for construct and concurrent validity. Less than two per cent of candidates would have failed the MMI. Conclusion The MMI is a moderately reliable method of assessment in the context of a National Assessment Centre approach. The largest source of error relates to aspects of interviewer subjectivity, suggesting enhanced interviewer training would be beneficial. MMIs need to be sufficiently long for precise comparison for ranking purposes. In order to justify long term sustainable use of the MMI in a postgraduate assessment centre

  15. Traveling wave linear accelerator with RF power flow outside of accelerating cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolgashev, Valery A.

    A high power RF traveling wave accelerator structure includes a symmetric RF feed, an input matching cell coupled to the symmetric RF feed, a sequence of regular accelerating cavities coupled to the input matching cell at an input beam pipe end of the sequence, one or more waveguides parallel to and coupled to the sequence of regular accelerating cavities, an output matching cell coupled to the sequence of regular accelerating cavities at an output beam pipe end of the sequence, and output waveguide circuit or RF loads coupled to the output matching cell. Each of the regular accelerating cavities hasmore » a nose cone that cuts off field propagating into the beam pipe and therefore all power flows in a traveling wave along the structure in the waveguide.« less

  16. [Cost of treatment and follow up of breast cancer: a retrospective assessment in a comprehensive cancer centre].

    PubMed

    Lilliu, Hervé; Stevens, Denise; Brun, Catherine; Morel, Julie; Pen, Claude Le; Bonastre, Julia; Bachelot, Florence; Davesne, Christian; Gentile, Annie; Hirlimann, Eric; Sabourin, Jean-Christophe; Berlie, Jacques; Rouëssé, Jacques

    2002-06-01

    Breast cancer is one of the major causes of premature death for women. Its cost management is important for both the national health insurance and the individual health care providers. The objective of this study was to assess the global medical cost of breast cancer from diagnosis to follow up in one French medical centre: centre René-Huguenin, Saint-Cloud (92). Duration of medical activities and other medical resources utilisations were collected from a retrospective cohort of 120 patients followed from January 1995 to February 2000. Unit costs were obtained from cost accounts of the Centre. The mean medical cost per patient was FF 66,067 [60,318-7,815] (USD $ 10,744 [9,809-11,679]). The mean cost varied from FF 41,875 (UDS $ 6,810) to FF 81,020 (UDS $ 13,175) depending on choice of type of therapy. The initial treatment phase was the most expensive, costing FF 48,397 [46,176-50,617] (USD $ 7,870 [7,509-8,231]) which represented 73.3% of the global cost. This study has provided an estimate of the real global cost of managing patients with breast cancer in a single French Comprehensive Cancer Centre (CLCC). The study method used is readily transposable to other treatment contexts and to other types of cancer.

  17. Development of bipolar-pulse accelerator for intense pulsed ion beam acceleration

    NASA Astrophysics Data System (ADS)

    Masugata, Katsumi; Shimizu, Yuichro; Fujioka, Yuhki; Kitamura, Iwao; Tanoue, Hisao; Arai, Kazuo

    2004-12-01

    To improve the purity of intense pulsed ion beams, a new type of pulsed ion beam accelerator named "bipolar pulse accelerator" was proposed. To confirm the principle of the accelerator a prototype of the experimental system was developed. The system utilizes By type magnetically insulated acceleration gap and operated with single polar negative pulse. A coaxial gas puff plasma gun was used as an ion source, which was placed inside the grounded anode. Source plasma (nitrogen) of current density ≈25 A/cm2, duration ≈1.5 μs was injected into the acceleration gap by the plasma gun. The ions were successfully accelerated from the grounded anode to the drift tube by applying negative pulse of voltage 240 kV, duration 100 ns to the drift tube. Pulsed ion beam of current density ≈40 A/cm2, duration ≈50 ns was obtained at 41 mm downstream from the anode surface. To evaluate the irradiation effect of the ion beam to solid material, an amorphous silicon thin film of thickness ≈500 nm was used as the target, which was deposited on the glass substrate. The film was found to be poly-crystallized after 4-shots of the pulsed nitrogen ion beam irradiation.

  18. Compact particle accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elizondo-Decanini, Juan M.

    2017-08-29

    A compact particle accelerator having an input portion configured to receive power to produce particles for acceleration, where the input portion includes a switch, is provided. In a general embodiment, a vacuum tube receives particles produced from the input portion at a first end, and a plurality of wafer stacks are positioned serially along the vacuum tube. Each of the plurality of wafer stacks include a dielectric and metal-oxide pair, wherein each of the plurality of wafer stacks further accelerate the particles in the vacuum tube. A beam shaper coupled to a second end of the vacuum tube shapes themore » particles accelerated by the plurality of wafer stacks into a beam and an output portion outputs the beam.« less

  19. Accelerating gradient improvement using shape-tailor laser front in radiation pressure acceleration progress

    NASA Astrophysics Data System (ADS)

    Wang, W. P.; Shen, B. F.; Xu, Z. Z.

    2017-05-01

    The accelerating gradient of a proton beam is crucial for stable radiation pressure acceleration (RPA) because the multi-dimensional instabilities increase γ times slower in the relativistic region. In this paper, a shape-tailored laser is proposed to significantly accelerate the ions in a controllable high accelerating gradient. In this method, the fastest ions initially rest in the middle of the foil are controlled to catch the compressed electron layer at the end of the hole-boring stage, thus the light-sail stage can start as soon as possible. Then the compressed electron layer is accelerated tightly together with the fastest ions by the shaped laser intensity, which further increases the accelerating gradient in the light-sail stage. Such tailored pulse may be beneficial for the RPA driven by the 10-fs 10 petawatt laser in the future.

  20. Accelerator Facilities for Radiation Research

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.

    1999-01-01

    HSRP Goals in Accelerator Use and Development are: 1.Need for ground-based heavy ion and proton facility to understand space radiation effects discussed most recently by NAS/NRC Report (1996). 2. Strategic Program Goals in facility usage and development: -(1) operation of AGS for approximately 600 beam hours/year; (2) operation of Loma Linda University (LLU) proton facility for approximately 400 beam hours/year; (3) construction of BAF facility; and (4) collaborative research at HIMAC in Japan and with other existing or potential international facilities. 3. MOA with LLU has been established to provide proton beams with energies of 40-250 important for trapped protons and solar proton events. 4. Limited number of beam hours available at Brookhaven National Laboratory's (BNL) Alternating Gradient Synchrotron (AGS).