Sample records for national mammography quality

  1. [Effectiveness of a quality control program in mammography for the Brazilian National Health System].

    PubMed

    Corrêa, Rosangela da Silveira; Freitas-Junior, Ruffo; Peixoto, João Emílio; Rodrigues, Danielle Cristina Netto; Lemos, Maria Eugênia Fonseca; Dias, Cíntia Melazo; Ferreira, Rubemar de Souza; Rahal, Rosemar Macedo Souza

    2012-10-01

    To assess the effectiveness of a quality control program in mammography services of the Brazilian National Health System (SUS). A prospective study using temporal analysis of a health surveillance action was conducted. A total of 35 service providers that had mammography equipment in operation and regularly performed exams between 2007 and 2009 in the state of Goiás, Central-Western Brazil, participated in this study. Services were assessed during three site visits by performance testing of mammography equipment, film processors, and other materials, and image quality and entrance surface dose in a phantom were also assessed. Each service was scored according to the percentage of tests that conformed to standards. The mean percentage for compliance among the participating service providers were 64.1% (± 13.3%) in the first visit, 68.4% (± 15.9%) in the second, and 77.1% (± 13.3%) in the third (p < 0.001). The main improvements resulted from adjustments to the breast compression force, the automatic exposure control system, and the alignment of the compression paddle. The doses measured were within the conformity range in 80% of the services assessed. The implementation of this program in the mammography services was effective at improving the operational parameters of the mammography machines, although 40% of the services did not reach the acceptable level of 70%. This result indicates the need to continue this health surveillance action.

  2. 76 FR 60848 - National Mammography Quality Assurance Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    .../phone line to learn about possible modifications before coming to the meeting. Agenda: On November 4... status of the Full Field Digital Mammography universal quality control manual. FDA intends to make...

  3. Quality assurance and ergonomics in the mammography department.

    PubMed

    Reynolds, April

    2014-01-01

    Quality assurance (QA) in mammography is a system of checks that helps ensure the proper functioning of imaging equipment and processes. Ergonomics is a scientific approach to arranging the work environment to reduce the risk of work-related injuries while increasing staff productivity and job satisfaction. This article reviews both QA and ergonomics in mammography and explains how they work together to create a safe and healthy environment for radiologic technologists and their patients. QA and quality control requirements in mammography are discussed, along with ergonomic best practices in the mammography setting.

  4. TL dosimetry for quality control of CR mammography imaging systems

    NASA Astrophysics Data System (ADS)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  5. Reproducibility of Mammography Units, Film Processing and Quality Imaging

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique

    2003-09-01

    The purpose of this study was to carry out an exploratory survey of the problems of quality control in mammography and processors units as a diagnosis of the current situation of mammography facilities. Measurements of reproducibility, optical density, optical difference and gamma index are included. Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is a radiographic examination specially designed for detecting breast pathology. We found that the problems of reproducibility of AEC are smaller than the problems of processors units because almost all processors fall outside of the acceptable variation limits and they can affect the mammography quality image and the dose to breast. Only four mammography units agree with the minimum score established by ACR and FDA for the phantom image.

  6. Automated daily quality control analysis for mammography in a multi-unit imaging center.

    PubMed

    Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli

    2018-01-01

    Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

  7. Position paper: recommendations for a digital mammography quality assurance program V4.0.

    PubMed

    Heggie, J C P; Barnes, P; Cartwright, L; Diffey, J; Tse, J; Herley, J; McLean, I D; Thomson, F J; Grewal, R K; Collins, L T

    2017-09-01

    In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation of digital mammography has been realised and it has become evident that existing screen-film protocols were not appropriate to assure the required image quality needed for reliable diagnosis or to address the new dose implications resulting from digital technology. In addition, the advantages and responsibilities inherent in teleradiology are most critical in mammography and also need to be addressed. The current document is the result of a review of current overseas practice and local experience in these areas. At this time the technology of digital imaging is undergoing significant development and there is still a lack of full international consensus about some of the detailed quality control (QC) tests that should be included in quality assurance (QA) programs. This document describes the current status in digital mammography QA and recommends test procedures that may be suitable in the Australasian environment. For completeness, this document also includes a review of the QA programs required for the various types of digital biopsy units used in mammography. In the future, international harmonisation of digital quality assurance in mammography and changes in the technology may require a review of this document. Version 2.0 represented the first of these updates and key changes related to image quality evaluation, ghost image evaluation and interpretation of signal to noise ratio measurements. In Version 3.0 some significant changes, made in light of further experience gained in testing digital mammography equipment were introduced. In Version 4.0, further changes have been made, most notably digital breast tomosynthesis (DBT) testing and QC have

  8. Quality assurance in mammography: artifact analysis.

    PubMed

    Hogge, J P; Palmer, C H; Muller, C C; Little, S T; Smith, D C; Fatouros, P P; de Paredes, E S

    1999-01-01

    Evaluation of mammograms for artifacts is essential for mammographic quality assurance. A variety of mammographic artifacts (i.e., variations in mammographic density not caused by true attenuation differences) can occur and can create pseudolesions or mask true abnormalities. Many artifacts are readily identified, whereas others present a true diagnostic challenge. Factors that create artifacts may be related to the processor (eg, static, dirt or excessive developer buildup on the rollers, excessive roller pressure, damp film, scrapes and scratches, incomplete fixing, power failure, contaminated developer), the technologist (eg, improper film handling and loading, improper use of the mammography unit and related equipment, positioning and darkroom errors), the mammography unit (eg, failure of the collimation mirror to rotate, grid inhomogeneity, failure of the reciprocating grid to move, material in the tube housing, compression failure, improper alignment of the compression paddle with the Bucky tray, defective compression paddle), or the patient (e.g., motion, superimposed objects or substances [jewelry, body parts, clothing, hair, implanted medical devices, foreign bodies, substances on the skin]). Familiarity with the broad range of artifacts and the measures required to eliminate them is vital. Careful attention to darkroom cleanliness, care in film handling, regularly scheduled processor maintenance and chemical replenishment, daily quality assurance activities, and careful attention to detail during patient positioning and mammography can reduce or eliminate most mammographic artifacts.

  9. [Quality assurance of fine-needle aspiration cytology of the organized mammography screening].

    PubMed

    Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós

    2010-08-08

    The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (p<0.001). The auditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.

  10. Automatic assessment of the quality of patient positioning in mammography

    NASA Astrophysics Data System (ADS)

    Bülow, Thomas; Meetz, Kirsten; Kutra, Dominik; Netsch, Thomas; Wiemker, Rafael; Bergtholdt, Martin; Sabczynski, Jörg; Wieberneit, Nataly; Freund, Manuela; Schulze-Wenck, Ingrid

    2013-02-01

    Quality assurance has been recognized as crucial for the success of population-based breast cancer screening programs using x-ray mammography. Quality guidelines and criteria have been defined in the US as well as the European Union in order to ensure the quality of breast cancer screening. Taplin et al. report that incorrect positioning of the breast is the major image quality issue in screening mammography. Consequently, guidelines and criteria for correct positioning and for the assessment of the positioning quality in mammograms play an important role in the quality standards. In this paper we present a system for the automatic evaluation of positioning quality in mammography according to the existing standardized criteria. This involves the automatic detection of anatomic landmarks in medio- lateral oblique (MLO) and cranio-caudal (CC) mammograms, namely the pectoral muscle, the mammilla and the infra-mammary fold. Furthermore, the detected landmarks are assessed with respect to their proper presentation in the image. Finally, the geometric relations between the detected landmarks are investigated to assess the positioning quality. This includes the evaluation whether the pectoral muscle is imaged down to the mammilla level, and whether the posterior nipple line diameter of the breast is consistent between the different views (MLO and CC) of the same breast. Results of the computerized assessment are compared to ground truth collected from two expert readers.

  11. Quality assurance and quality control in mammography: a review of available guidance worldwide.

    PubMed

    Reis, Cláudia; Pascoal, Ana; Sakellaris, Taxiarchis; Koutalonis, Manthos

    2013-10-01

    Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources. •An effective QA program should be practical to implement in a clinical setting. •QA should address the various stages of the imaging chain: acquisition, processing and display. •AEC system QC testing is simple to implement and provides information on equipment performance.

  12. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    PubMed

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  13. Quality assurance in mammography: College of Radiology Survey in Malaysia.

    PubMed

    Ho, E L M; Ng, K H; Wong, J H D; Wang, H B

    2006-06-01

    Malaysia's mammography QA practice was surveyed based on the Malaysian Ministry of Health and the American College of Radiology (ACR) requirements. Data on mammography unit, processor, image receptor, exposure factors, mean glandular dose (MGD), sensitometry, image quality and viewbox luminance were obtained. Mean developer temperature and cycle time were 34.1 +/- 1.8degreesC and 107.7 +/- 33.2 seconds. Mean base+fog level, speed index and contrast index were 0.20+/-0.01, 1.20+/-0.01 and 1.33+/-0.26 respectively. Eighty-six percent of the fifty centres passed the image quality test while 12.5% complied with ACR recommended viewbox luminance. Average MGD was 1.0+/-0.4 mGy. Malaysia is on the right track for QA but with room for total quality improvement.

  14. The influence of software filtering in digital mammography image quality

    NASA Astrophysics Data System (ADS)

    Michail, C.; Spyropoulou, V.; Kalyvas, N.; Valais, I.; Dimitropoulos, N.; Fountos, G.; Kandarakis, I.; Panayiotakis, G.

    2009-05-01

    Breast cancer is one of the most frequently diagnosed cancers among women. Several techniques have been developed to help in the early detection of breast cancer such as conventional and digital x-ray mammography, positron and single-photon emission mammography, etc. A key advantage in digital mammography is that images can be manipulated as simple computer image files. Thus non-dedicated commercially available image manipulation software can be employed to process and store the images. The image processing tools of the Photoshop (CS 2) software usually incorporate digital filters which may be used to reduce image noise, enhance contrast and increase spatial resolution. However, improving an image quality parameter may result in degradation of another. The aim of this work was to investigate the influence of three sharpening filters, named hereafter sharpen, sharpen more and sharpen edges on image resolution and noise. Image resolution was assessed by means of the Modulation Transfer Function (MTF).In conclusion it was found that the correct use of commercial non-dedicated software on digital mammograms may improve some aspects of image quality.

  15. Implementation of a clinical quality control program in a mammography screening service of Brazil.

    PubMed

    DE Souza Sabino, Silvia Maria Prioli; Silva, Thiago Buosi; Watanabe, Anapaula Hidemi Uema; Syrjänen, Kari; Carvalho, André Lopes; Mauad, Edmundo Carvalho

    2014-09-01

    To evaluate the effect of a clinical quality control program on the final quality of a mammography screening service. We conducted retrospective assessment of the clinical quality of 5,000 mammograms taken in a Mammography Screening Program between November 2010 and September 2011, following the implementation of a Clinical Quality Control Program based on the European Guidelines. Among the 105,000 evaluated quality items, there were 8,588 failures (8.2%) - 1.7 failures per examination. Altogether, 89% of the failures were associated with positioning. The recall rate due to a technical error reached a maximum of 0.5% in the early phase of the observation period and subsequently stabilized (0.09%). The ongoing education and monitoring combined with personalized training increased the critical thinking of the involved professionals, reducing the technical failures and unnecessary exposure of patients to radiation, with substantial improvement in the final quality of mammography. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  16. Health-related quality of life, anxiety and depression related to mammography screening in Norway.

    PubMed

    Hafslund, Bjorg; Espehaug, Birgitte; Nortvedt, Monica Wammen

    2012-11-01

    To measure health-related quality of life, anxiety and depression ahead of mammography screening and to assess any differences in health-related quality of life compared to reference population. The study of health-related quality of life among attendees prior to mammography screening has received little attention, and increased knowledge is needed to better understand the overall health benefits of participation. A two-group cross-sectional comparative study was performed. The samples comprised 4,249 attendees to mammography screening and a comparison group of 943 women. We used the SF-36 Health Survey to assess health-related quality of life. Linear regression was used to study any differences between the groups with adjustment for age, level of education, occupation, having children and smoking status. Other normative data were also used. Anxiety and depression were assessed using the Hospital Anxiety and Depression Scale. Attendees scored statistically significant higher on the SF-36 than the comparison group but were in line with normative data. Attendees had anxiety mean 4·1 and depression mean 2·6. The majority of the attendees have a high health-related quality of life, low anxiety and depression ahead of screening. Anxiety and depression were less than shown in normative data from Norway. Despite a high health-related quality of life, low anxiety and depression among the majority, healthcare workers should pay special attention to the few women who are anxious and depressed, and have a lower health-related quality of life. Omitted from mammography screening may be women who are unemployed, have lower socioeconomic status, are anxious and are depressed. Further research should be performed with non-attendees and subgroups to improve the screening programme. It is important to identify which patients have the greatest need for support and caring in an organised mammography screening and who may be overlooked. © 2012 Blackwell Publishing Ltd.

  17. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    PubMed

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Eight years of quality control in Bulgaria: impact on mammography practice.

    PubMed

    Avramova-Cholakova, S; Lilkov, G; Kaneva, M; Terziev, K; Nakov, I; Mutkurov, N; Kovacheva, D; Ivanova, M; Vasilev, D

    2015-07-01

    The requirements for quality control (QC) in diagnostic radiology were introduced in Bulgarian legislation in 2005. Hospital medical physicists and several private medical physics groups provide QC services to radiology departments. The aim of this study was to analyse data from QC tests in mammography and to investigate the impact of QC introduction on mammography practice in the country. The study was coordinated by the National Centre of Radiobiology and Radiation Protection. All medical physics services were requested to fill in standardised forms with information about most important parameters routinely measured during QC. All QC service providers responded. Results demonstrated significant improvement of practice since the introduction of QC, with reduction of established deviations from 65 % during the first year to 7 % in the last year. The systems that do not meet the acceptability criteria were suspended from use. Performance of automatic exposure control and digital detectors are not regularly tested because of the absence of requirements in the legislation. The need of updated guidance and training of medical physicists to reflect the change in technology was demonstrated. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Digital information management: a progress report on the National Digital Mammography Archive

    NASA Astrophysics Data System (ADS)

    Beckerman, Barbara G.; Schnall, Mitchell D.

    2002-05-01

    Digital mammography creates very large images, which require new approaches to storage, retrieval, management, and security. The National Digital Mammography Archive (NDMA) project, funded by the National Library of Medicine (NLM), is developing a limited testbed that demonstrates the feasibility of a national breast imaging archive, with access to prior exams; patient information; computer aids for image processing, teaching, and testing tools; and security components to ensure confidentiality of patient information. There will be significant benefits to patients and clinicians in terms of accessible data with which to make a diagnosis and to researchers performing studies on breast cancer. Mammography was chosen for the project, because standards were already available for digital images, report formats, and structures. New standards have been created for communications protocols between devices, front- end portal and archive. NDMA is a distributed computing concept that provides for sharing and access across corporate entities. Privacy, auditing, and patient consent are all integrated into the system. Five sites, Universities of Pennsylvania, Chicago, North Carolina and Toronto, and BWXT Y12, are connected through high-speed networks to demonstrate functionality. We will review progress, including technical challenges, innovative research and development activities, standards and protocols being implemented, and potential benefits to healthcare systems.

  20. Implementation of the qualities of radiodiagnostic: mammography

    NASA Astrophysics Data System (ADS)

    Pacífico, L. C.; Magalhães, L. A. G.; Peixoto, J. G. P.; Fernandes, E.

    2018-03-01

    The objective of the present study was to evaluate the expanded uncertainty of the mammographic calibration process and present the result of the internal audit performed at the Laboratory of Radiological Sciences (LCR). The qualities of the mammographic beans that are references in the LCR, comprises two irradiation conditions: no-attenuated beam and attenuated beam. Both had satisfactory results, with an expanded uncertainty equals 2,1%. The internal audit was performed, and the degree of accordance with the ISO/IEC 17025 was evaluated. The result of the internal audit was satisfactory. We conclude that LCR can perform calibrations on mammography qualities for end users.

  1. Advanced Breast Cancer as Indicator of Quality Mammography

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique

    2003-09-01

    Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is the more important screening tool for detecting early breast cancer. Screening mammography involves taking x-rays from two views from each breast, typically from above (cranial-caudal view, CC) and from an oblique or angled view (mediolateral-oblique, MLO). The purpose of this study was to carry out an exploratory survey of the issue of patients with advanced breast cancer who have had a screening mammography. A general result of the survey is that 22.5% of all patients (102) with advanced breast cancer that participated in the study had previous screening mammography. But we should consider that 10% of breast cancers are not detected by mammography. Only 70% of the family doctors prescribed a diagnostic mammography when the first symptoms were diagnosed.

  2. Effect of exposure factors on image quality in screening mammography.

    PubMed

    Alkhalifah, K; Brindabhan, A; Alsaeed, R

    2017-11-01

    The aim of this research was to study the effect of exposure factors on image quality for digital screening mammography units in Kuwait which use Tungsten (W) targets with Rhodium (Rh) and Silver (Ag) as filters. Mammography Accreditation Phantom Model 015 was imaged using a Hologic Selenia Digital mammography unit with W targets and Rh and Ag filters. Four images, each at 26, 28, 30, and 32 kVp, were obtained using each target-filter combination (W/Rh and W/Ag). The images were evaluated by five senior technologists for the number of specks, fibers and masses visible on each image. Statistical analysis was carried out using non-parametric tests at p = 0.05 level. There were significant changes in the visibility of fibers and specks between different kVp values with W/Rh (p < 0.001). However, with W/Ag combination, significant differences were observed in the fibers only (p < 0.001). Among the kVp values used, 28 kV emerged as the optimal value. Comparison of images obtained with the two filter materials, led to significant differences in the visibility of fibers and specks (p < 0.008). At 32 kVp, there were significant differences in the visibility of specks only (p < 0.008). A W/Rh target-filter combination provides better image quality than that provided by W/Ag. In particular, 30 and 32 kVp X-ray beams produce higher quality images than the lower kV values. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  3. Auditing and benchmarks in screening and diagnostic mammography.

    PubMed

    Feig, Stephen A

    2007-09-01

    Radiologists can use outcome data such as cancer size and stage to determine how well their own practice provides benefit to their patients and can use measures such as screening recall rates and positive predictive values to assess how well adverse consequences are being contained. New data on national benchmarks for screening and diagnostic mammography in the United States allow radiologists to evaluate their own performance with respect to their peers. This article discusses recommended outcome values in the United States and Europe, current Mammography Quality Standards Act audit requirements, and Institute of Medicine proposals for future requirements.

  4. Cost and cost-effectiveness of digital mammography compared with film-screen mammography in Australia.

    PubMed

    Wang, Shuhong; Merlin, Tracy; Kreisz, Florian; Craft, Paul; Hiller, Janet E

    2009-10-01

    A systematic review assessed the relative safety and effectiveness of digital mammography compared with film-screen mammography. This study utilised the evidence from the review to examine the economic value of digital compared with film-screen mammography in Australia. A cost-comparison analysis between the two technologies was conducted for the overall population for the purposes of breast cancer screening and diagnosis. In addition, a cost-effectiveness analysis was conducted for the screening subgroups where digital mammography was considered to be more accurate than film-screen mammography. Digital mammography in a screening setting is $11 more per examination than film-screen mammography, and $36 or $33 more per examination in a diagnostic setting when either digital radiography or computed radiography is used. In both the screening and diagnostic settings, the throughput of the mammography system had the most significant impact on decreasing the incremental cost/examination/year of digital mammography. Digital mammography is more expensive than film-screen mammography. Whether digital mammography represents good value for money depends on the eventual life-years and quality-adjusted life-years gained from the early cancer diagnosis. The evidence generated from this study has informed the allocation of public resources for the screening and diagnosis of breast cancer in Australia.

  5. Web-based mammography audit feedback.

    PubMed

    Geller, Berta M; Ichikawa, Laura; Miglioretti, Diana L; Eastman, David

    2012-06-01

    Interpreting screening mammography accurately is challenging and requires ongoing education to maintain and improve interpretative skills. Recognizing this, many countries with organized breast screening programs have developed audit and feedback systems using national performance data to help radiologists assess and improve their skills. We developed and tested an interactive Website to provide screening and diagnostic mammography audit feedback with comparisons to national and regional benchmarks. Radiologists who participate in three Breast Cancer Surveillance Consortium registries in the United States were invited during 2009 and 2010 to use a Website that provides tabular and graphical displays of mammography audit reports with comparisons to national and regional performance measures. We collected data about the use and perceptions of the Website. Thirty-five of 111 invited radiologists used the Website from one to five times in a year. The most popular measure was sensitivity for both screening and diagnostic mammography, whereas a table with all measures was the most visited page. Of the 13 radiologists who completed the postuse survey, all found the Website easy to use and navigate, 11 found the benchmarks useful, and nine reported that they intended to improve a specific outcome measure that year. An interactive Website to provide customized mammography audit feedback reports to radiologists has the potential to be a powerful tool in improving interpretive performance. The conceptual framework of customized audit feedback reports can also be generalized to other imaging tests.

  6. Mammography: MedlinePlus Health Topic

    MedlinePlus

    ... National Center for Health Statistics) MQSA National Statistics (Food and Drug Administration) Women with Disabilities and Breast Cancer Screening (Centers for Disease Control and Prevention) Clinical Trials ClinicalTrials.gov: Mammography (National Institutes of ...

  7. Conclusions for mammography screening after 25-year follow-up of the Canadian National Breast Cancer Screening Study (CNBSS).

    PubMed

    Heywang-Köbrunner, S H; Schreer, I; Hacker, A; Noftz, M R; Katalinic, A

    2016-02-01

    Twenty-five-year follow-up data of the Canadian National Breast Cancer Screening Study (CNBSS) indicated no mortality reduction. What conclusions should be drawn? After conducting a systematic literature search and narrative analysis, we wish to recapitulate important details of this study, which may have been neglected: Sixty-eight percent of all included cancers were palpable, a situation that does not allow testing the value of early detection. Randomisation was performed at the sites after palpation, while blinding was not guaranteed. In the first round, this "randomisation" assigned 19/24 late stage cancers to the mammography group and only five to the control group, supporting the suspicion of severe errors in the randomisation process. The responsible physicist rated mammography quality as "far below state of the art of that time". Radiological advisors resigned during the study due to unacceptable image quality, training, and medical quality assurance. Each described problem may strongly influence the results between study and control groups. Twenty-five years of follow-up cannot heal these fundamental problems. This study is inappropriate for evidence-based conclusions. The technology and quality assurance of the diagnostic chain is shown to be contrary to today's screening programmes, and the results of the CNBSS are not applicable to them. • The evidence base of the Canadian study (CNBSS) has to be questioned.• Severe flaws in the randomization process and test methods occurred. • Problems were criticized during and after conclusion of the trial by experts.• The results are not applicable to quality-assured screening programs. • The evidence base of this study must be re-analyzed.

  8. A new full-field digital mammography system with and without the use of an advanced post-processing algorithm: comparison of image quality and diagnostic performance.

    PubMed

    Ahn, Hye Shin; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Kim, Bohyoung; Ko, Eun Sook; Han, Boo-Kyung; Chang, Jung Min; Yi, Ann; Cho, Nariya; Moon, Woo Kyung; Choi, Hye Young

    2014-01-01

    To compare new full-field digital mammography (FFDM) with and without use of an advanced post-processing algorithm to improve image quality, lesion detection, diagnostic performance, and priority rank. During a 22-month period, we prospectively enrolled 100 cases of specimen FFDM mammography (Brestige®), which was performed alone or in combination with a post-processing algorithm developed by the manufacturer: group A (SMA), specimen mammography without application of "Mammogram enhancement ver. 2.0"; group B (SMB), specimen mammography with application of "Mammogram enhancement ver. 2.0". Two sets of specimen mammographies were randomly reviewed by five experienced radiologists. Image quality, lesion detection, diagnostic performance, and priority rank with regard to image preference were evaluated. Three aspects of image quality (overall quality, contrast, and noise) of the SMB were significantly superior to those of SMA (p < 0.05). SMB was significantly superior to SMA for visualizing calcifications (p < 0.05). Diagnostic performance, as evaluated by cancer score, was similar between SMA and SMB. SMB was preferred to SMA by four of the five reviewers. The post-processing algorithm may improve image quality with better image preference in FFDM than without use of the software.

  9. A study on mastectomy samples to evaluate breast imaging quality and potential clinical relevance of differential phase contrast mammography.

    PubMed

    Hauser, Nik; Wang, Zhentian; Kubik-Huch, Rahel A; Trippel, Mafalda; Singer, Gad; Hohl, Michael K; Roessl, Ewald; Köhler, Thomas; van Stevendaal, Udo; Wieberneit, Nataly; Stampanoni, Marco

    2014-03-01

    Differential phase contrast and scattering-based x-ray mammography has the potential to provide additional and complementary clinically relevant information compared with absorption-based mammography. The purpose of our study was to provide a first statistical evaluation of the imaging capabilities of the new technique compared with digital absorption mammography. We investigated non-fixed mastectomy samples of 33 patients with invasive breast cancer, using grating-based differential phase contrast mammography (mammoDPC) with a conventional, low-brilliance x-ray tube. We simultaneously recorded absorption, differential phase contrast, and small-angle scattering signals that were combined into novel high-frequency-enhanced images with a dedicated image fusion algorithm. Six international, expert breast radiologists evaluated clinical digital and experimental mammograms in a 2-part blinded, prospective independent reader study. The results were statistically analyzed in terms of image quality and clinical relevance. The results of the comparison of mammoDPC with clinical digital mammography revealed the general quality of the images to be significantly superior (P < 0.001); sharpness, lesion delineation, as well as the general visibility of calcifications to be significantly more assessable (P < 0.001); and delineation of anatomic components of the specimens (surface structures) to be significantly sharper (P < 0.001). Spiculations were significantly better identified, and the overall clinically relevant information provided by mammoDPC was judged to be superior (P < 0.001). Our results demonstrate that complementary information provided by phase and scattering enhanced mammograms obtained with the mammoDPC approach deliver images of generally superior quality. This technique has the potential to improve radiological breast diagnostics.

  10. Characterizing the Mammography Technologist Workforce in North Carolina.

    PubMed

    Henderson, Louise M; Marsh, Mary W; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F; Bowling, J Michael; Viglione, Cheryl A; Yankaskas, Bonnie C

    2015-12-01

    Mammography technologists' level of training, years of experience, and feedback on technique may play an important role in the breast-cancer screening process. However, information on the mammography technologist workforce is scant. In 2013, we conducted a survey mailed to 912 mammography technologists working in 224 facilities certified by the Mammography Quality Standards Act in North Carolina. Using standard survey methodology, we developed and implemented a questionnaire on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for nonresponse. We describe and compare lead (administrative responsibilities) and nonlead (supervised by another technologist) mammography technologist characteristics, testing for differences, using t-tests and χ(2) analysis. A total of 433 mammography technologists responded (survey response rate = 47.5%; 95% confidence interval [CI]: 44.2%-50.7%), including 128 lead and 305 nonlead technologists. Most mammography technologists were non-Hispanic, white women; their average age was 48 years. Approximately 93% of lead and nonlead technologists had mammography-specific training, but <4% had sonography certification, and 3% had MRI certification. Lead technologists reported more years of experience performing screening mammography (P = .02) and film mammography (P = .03), more administrative hours (P < .0001), and more workplace autonomy (P = .002) than nonlead technologists. Nonlead technologists were more likely to report performing diagnostic mammograms (P = .0004) or other breast imaging (P = .001), discuss image quality with a peer (P = .013), and have frequent face-to-face interaction with radiologists (P = .03). Our findings offer insights into mammography technologists' training and work experiences, highlighting variability in characteristics of lead versus nonlead technologists. Copyright © 2015 American College of

  11. Characterizing the mammography technologist workforce in North Carolina

    PubMed Central

    Henderson, Louise M.; Marsh, Mary W.; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F.; Bowling, J. Michael; Viglione, Cheryl A.; Yankaskas, Bonnie C.

    2016-01-01

    Background Mammography technologists’ level of training, years of experience, and feedback on technique may play an important role in the breast cancer screening process. However, very little information on the mammography technologist workforce exists. Methods In 2013, we conducted a mailed survey to 912 mammography technologists working in 224 Mammography Quality Standards Act accredited facilities in North Carolina. Using standard survey methodology we developed and implemented a questionnaire focused on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for non-response. We describe and compare lead (administrative responsibilities) and non-lead (supervised by another technologist) mammography technologist characteristics, testing for differences using t-tests and chi-square tests. Results A total of 433 mammography technologists responded (survey response rate=47.5%; 95% confidence interval:44.2%-50.7%), including 128 lead and 305 non-lead technologists. Most mammography technologists were non-Hispanic, white, females and the average age was 48 years. Approximately 93% of lead and non-lead technologists had mammography specific training but <4% had sonography certification and 3% had MRI certification. Lead technologists reported more years performing screening mammography (p-value=0.02) and film mammography (p-value=0.03), more administrative hours (p-value<0.0001), and more workplace autonomy (p-value=0.002) than non-lead technologists. Non-lead technologists were more likely to report performing diagnostic mammograms (p-value=0.0004) or other breast imaging (p-value=0.001), discuss image quality with a peer (p-value=0.013), and have frequent face-to-face interaction with radiologists (p-value=0.03). Conclusion Our findings offer insights into mammography technologists’ training and work experiences, highlighting variability in technologist

  12. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts.

    PubMed

    Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D

    2015-03-01

    To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.

  13. Mammography in females with an implanted medical device: impact on image quality, pain and anxiety.

    PubMed

    Paap, Ellen; Witjes, Marloes; van Landsveld-Verhoeven, Cary; Pijnappel, Ruud M; Maas, Angela H E M; Broeders, Mireille J M

    2016-10-01

    To assess the image quality of mammograms in females with an implanted medical device (IMD), to evaluate pain and anxiety during mammography in these females and to investigate the experience of radiographers. Image quality was evaluated by two radiographers and one radiologist in the images of females with an IMD participating in the Dutch screening programme (clients). Pain and anxiety were scored using a Numeric Rating Scale in both clients visiting a screening organization and patients from the Isala Hospital, Zwolle. Experience of screening radiographers was collected with a questionnaire. Images of the breast with IMD showed reduced contrast in craniocaudal (CC) and mediolateral-oblique (MLO) views [by both the radiographers and radiologist (range: 11-29%)], less projected breast tissue [only radiographers; CC lateral side: 25.5%, 95% confidence interval (CI): 18.7-32.2] and reduced projection of the pectoral muscle (only radiographers; MLO width pectoral muscle: 31.5%, 95% CI: 24.4-38.7). Clients experienced more pain and anxiety during mammography in the breast with IMD compared to the breast without IMD in the breast (pain difference CC: 0.48 ± 0.16, p = 0.003; pain difference MLO: 0.46 ± 0.16, p = 0.004; anxiety difference 1.30 ± 0.22; p < 0.001). Patients experienced more pain (1.05 ± 0.12; p < 0.001) and anxiety (1.22 ± 0.15; p < 0.001) after placement of IMD. Radiographers are more cautious, more anxious and use less compression during mammography of breasts with IMD. Image quality in a breast with an IMD could be improved by projecting more breast tissue on the mammogram, thereby including (part of) the IMD between the paddles, if required. In addition, radiographers should pay sufficient attention to reducing discomfort both before and during the screening examination. Little is known about the quality of mammography in females with an IMD or how these females and radiographers experience the screening

  14. MASTOS: Mammography Simulation Tool for design Optimization Studies.

    PubMed

    Spyrou, G; Panayiotakis, G; Tzanakos, G

    2000-01-01

    Mammography is a high quality imaging technique for the detection of breast lesions, which requires dedicated equipment and optimum operation. The design parameters of a mammography unit have to be decided and evaluated before the construction of such a high cost of apparatus. The optimum operational parameters also must be defined well before the real breast examination. MASTOS is a software package, based on Monte Carlo methods, that is designed to be used as a simulation tool in mammography. The input consists of the parameters that have to be specified when using a mammography unit, and also the parameters specifying the shape and composition of the breast phantom. In addition, the input may specify parameters needed in the design of a new mammographic apparatus. The main output of the simulation is a mammographic image and calculations of various factors that describe the image quality. The Monte Carlo simulation code is PC-based and is driven by an outer shell of a graphical user interface. The entire software package is a simulation tool for mammography and can be applied in basic research and/or in training in the fields of medical physics and biomedical engineering as well as in the performance evaluation of new designs of mammography units and in the determination of optimum standards for the operational parameters of a mammography unit.

  15. Assessment of automatic exposure control performance in digital mammography using a no-reference anisotropic quality index

    NASA Astrophysics Data System (ADS)

    Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.

    2017-03-01

    Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.

  16. Contrast-enhanced Spectral Mammography: Modality-Specific Artifacts and Other Factors Which May Interfere with Image Quality.

    PubMed

    Bhimani, Chandni; Li, Luna; Liao, Lydia; Roth, Robyn G; Tinney, Elizabeth; Germaine, Pauline

    2017-01-01

    Contrast-enhanced spectral mammography (CESM) uses full field digital mammography with the added benefit of intravenous contrast administration to significantly reduce false-positive and false-negative results and improve specificity while maintaining high sensitivity. For CESM to fulfill its purpose, one should be aware of possible artifacts and other factors which may interfere with image quality, and attention should be taken to minimize these factors. This pictorial demonstration will depict types of artifacts detected and other factors that interfere with image acquisition in our practice since CESM implementation. Many of the artifacts and other factors we have encountered while using CESM have simple solutions to resolve them. The illustrated artifacts and other factors interfering with image quality will serve as a useful reference to anyone using CESM. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Cost-effectiveness of digital mammography breast cancer screening.

    PubMed

    Tosteson, Anna N A; Stout, Natasha K; Fryback, Dennis G; Acharyya, Suddhasatta; Herman, Benjamin A; Hannah, Lucy G; Pisano, Etta D

    2008-01-01

    The DMIST (Digital Mammography Imaging Screening Trial) reported improved breast cancer detection with digital mammography compared with film mammography in selected population subgroups, but it did not assess the economic value of digital relative to film mammography screening. To evaluate the cost-effectiveness of digital mammography screening for breast cancer. Validated, discrete-event simulation model. Data from DMIST and publicly available U.S. data. U.S. women age 40 years or older. Lifetime. Societal and Medicare. All-film mammography screening; all-digital mammography screening; and targeted digital mammography screening, which is age-targeted digital mammography (for women <50 years of age) and age- and density-targeted digital mammography (for women <50 years of age or women > or =50 years of age with dense breasts). Cost per quality-adjusted life-year (QALY) gained. All-digital mammography screening cost $331,000 (95% CI, $268,000 to $403,000) per QALY gained relative to all-film mammography screening but was more costly and less effective than targeted digital mammography screening. Targeted digital mammography screening resulted in more screen-detected cases of cancer and fewer deaths from cancer than either all-film or all-digital mammography screening, with cost-effectiveness estimates ranging from $26,500 (CI, $21,000 to $33,000) per QALY gained for age-targeted digital mammography to $84,500 (CI, $75,000 to $93,000) per QALY gained for age- and density-targeted digital mammography. In the Medicare population, the cost-effectiveness of density-targeted digital mammography screening varied from a base-case estimate of $97,000 (CI, $77,000 to $131,000) to $257,000 per QALY gained (CI, $91,000 to $536,000) in the alternative-case analyses, in which the sensitivity of film mammography was increased and the sensitivity of digital mammography in women with nondense breasts was decreased. Results were sensitive to the cost of digital mammography and to

  18. National Performance Benchmarks for Modern Diagnostic Digital Mammography: Update from the Breast Cancer Surveillance Consortium.

    PubMed

    Sprague, Brian L; Arao, Robert F; Miglioretti, Diana L; Henderson, Louise M; Buist, Diana S M; Onega, Tracy; Rauscher, Garth H; Lee, Janie M; Tosteson, Anna N A; Kerlikowske, Karla; Lehman, Constance D

    2017-04-01

    Purpose To establish contemporary performance benchmarks for diagnostic digital mammography with use of recent data from the Breast Cancer Surveillance Consortium (BCSC). Materials and Methods Institutional review board approval was obtained for active or passive consenting processes or to obtain a waiver of consent to enroll participants, link data, and perform analyses. Data were obtained from six BCSC registries (418 radiologists, 92 radiology facilities). Mammogram indication and assessments were prospectively collected for women undergoing diagnostic digital mammography and linked with cancer diagnoses from state cancer registries. The study included 401 548 examinations conducted from 2007 to 2013 in 265 360 women. Results Overall diagnostic performance measures were as follows: cancer detection rate, 34.7 per 1000 (95% confidence interval [CI]: 34.1, 35.2); abnormal interpretation rate, 12.6% (95% CI: 12.5%, 12.7%); positive predictive value (PPV) of a biopsy recommendation (PPV 2 ), 27.5% (95% CI: 27.1%, 27.9%); PPV of biopsies performed (PPV 3 ), 30.4% (95% CI: 29.9%, 30.9%); false-negative rate, 4.8 per 1000 (95% CI: 4.6, 5.0); sensitivity, 87.8% (95% CI: 87.3%, 88.4%); and specificity, 90.5% (95% CI: 90.4%, 90.6%). Among cancers detected, 63.4% were stage 0 or 1 cancers, 45.6% were minimal cancers, the mean size of invasive cancers was 21.2 mm, and 69.6% of invasive cancers were node negative. Performance metrics varied widely across diagnostic indications, with cancer detection rate (64.5 per 1000) and abnormal interpretation rate (18.7%) highest for diagnostic mammograms obtained to evaluate a breast problem with a lump. Compared with performance during the screen-film mammography era, diagnostic digital performance showed increased abnormal interpretation and cancer detection rates and decreasing PPVs, with less than 70% of radiologists within acceptable ranges for PPV 2 and PPV 3 . Conclusion These performance measures can serve as national

  19. Is Mammography Useful in Older Women

    DTIC Science & Technology

    1999-06-01

    mammography in women age 70 and older . Using the Linked Medicare-SEER Tumor Registry Database, created by the National Cancer Institute and the Health Care... Health Interview Survey) have documented that mammography use decreases with advancing age (11,21,22). In 1993, only 25% of women age 65 and older ...related health services research. The linked database contains cancer information on patients 65 years of age and older from NCI’s SEER Program and

  20. European radiographers' challenges from mammography education and clinical practice - an integrative review.

    PubMed

    Metsälä, Eija; Richli Meystre, Nicole; Pires Jorge, José; Henner, Anja; Kukkes, Tiina; Sá Dos Reis, Cláudia

    2017-06-01

    This study aims to identify European radiographers' challenges in clinical performance in mammography and the main areas of mammography that require more and better training. An extensive search was performed to identify relevant studies focused on clinical practice, education and training in mammography published between January 2010 and December 2015 in the English language. The data were analysed by using deductive thematic analysis. A total of 27 full text articles were read, evaluating their quality. Sixteen articles out of 27 were finally selected for this integrative review. The main challenges of radiographers' mammography education/training can be divided into three groups: training needs, challenges related to radiographers, and challenges related to the organization of education. The most common challenges of clinical performance in mammography among European radiographers involved technical performance, the quality of practices, and patient-centeredness. The introduction of harmonized mammography guidelines across Europe may serve as an evidence-based tool to be implemented in practice and education. However, the variability in human and material resources as well as the different cultural contexts should be considered during this process. • Radiographers' awareness of their professional identity and enhancing multiprofessional cooperation in mammography. • Radiographers' responsibilities regarding image quality (IQ) and optimal breast imaging performance. • Patient-centred mammography services focusing on the psychosocial needs of the patient. • Challenges: positioning, QC-testing, IQ-assessment, optimization of breast compression, communication, teamwork, and patient-centred care. • Introduction of evidence-based guidelines in Europe to harmonize mammography practice and education.

  1. Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography

    NASA Astrophysics Data System (ADS)

    Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang

    2017-10-01

    Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.

  2. An Exploration of Changes in the Measurement of Mammography in the National Health Interview Survey.

    PubMed

    Gonzales, Felisa A; Willis, Gordon B; Breen, Nancy; Yan, Ting; Cronin, Kathy A; Taplin, Stephen H; Yu, Mandi

    2017-11-01

    Background: Using the National Health Interview Survey (NHIS), we examined the effect of question wording on estimates of past-year mammography among racially/ethnically diverse women ages 40-49 and 50-74 without a history of breast cancer. Methods: Data from one-part ("Have you had a mammogram during the past 12 months?") and two-part ("Have you ever had a mammogram"; "When did you have your most recent mammogram?") mammography history questions administered in the 2008, 2011, and 2013 NHIS were analyzed. χ 2 tests provided estimates of changes in mammography when question wording was either the same (two-part question) or differed (two-part question followed by one-part question) in the two survey years compared. Crosstabulations and regression models assessed the type, extent, and correlates of inconsistent responses to the two questions in 2013. Results: Reports of past-year mammography were slightly higher in years when the one-part question was asked than when the two-part question was asked. Nearly 10% of women provided inconsistent responses to the two questions asked in 2013. Black women ages 50 to 74 [adjusted OR (aOR), 1.50; 95% confidence interval (CI), 1.16-1.93] and women ages 40-49 in poor health (aOR, 2.22; 95% CI, 1.09-4.52) had higher odds of inconsistent responses; women without a usual source of care had lower odds (40-49: aOR, 0.42; 95% CI, 0.21-0.85; 50-74: aOR, 0.42; 95% CI, 0.24-0.74). Conclusions: Self-reports of mammography are sensitive to question wording. Researchers should use equivalent questions that have been designed to minimize response biases such as telescoping and social desirability. Impact: Trend analyses relying on differently worded questions may be misleading and conceal disparities. Cancer Epidemiol Biomarkers Prev; 26(11); 1611-8. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. Cost-Effectiveness of Three Rounds of Mammography Breast Cancer Screening in Iranian Women

    PubMed Central

    Haghighat, Shahpar; Akbari, Mohammad Esmaeil; Yavari, Parvin; Javanbakht, Mehdi; Ghaffari, Shahram

    2016-01-01

    Background Breast cancer is the most common cancer in Iranian women as is worldwide. Mammography screening has been introduced as a beneficial method for reducing mortality and morbidity of this disease. Objectives We developed an analytical model to assess the cost effectiveness of an organized mammography screening program in Iran for early detection of the breast cancer. Patients and Methods This study is an economic evaluation of mammography screening program among Iranian woman aged 40 - 70 years. A decision tree and Markov model were applied to estimate total quality adjusted life years (QALY) and lifetime costs. Results The results revealed that the incremental cost effectiveness ratio (ICER) of mammography screening in Iranian women in the first round was Int. $ 37,350 per QALY gained. The model showed that the ICER in the second and third rounds of screening program were Int. $ 141,641 and Int. $ 389,148 respectively. Conclusions Study results identified that mammography screening program was cost-effective in 53% of the cases, but incremental cost per QALY in the second and third rounds of screening are much higher than the accepted payment threshold of Iranian health system. Thus, evaluation of other screening strategies would be useful to identify more cost-effective program. Future studies with new national data can improve the accuracy of our finding and provide better information for health policy makers for decision making. PMID:27366315

  4. ACR BI-RADS Assessment Category 4 Subdivisions in Diagnostic Mammography: Utilization and Outcomes in the National Mammography Database.

    PubMed

    Elezaby, Mai; Li, Geng; Bhargavan-Chatfield, Mythreyi; Burnside, Elizabeth S; DeMartini, Wendy B

    2018-05-01

    Purpose To determine the utilization and positive predictive value (PPV) of the American College of Radiology (ACR) Breast Imaging Data and Reporting System (BI-RADS) category 4 subdivisions in diagnostic mammography in the National Mammography Database (NMD). Materials and Methods This study involved retrospective review of diagnostic mammography data submitted to the NMD from January 1, 2008 to December 30, 2014. Utilization rates of BI-RADS category 4 subdivisions were compared by year, facility (type, location, census region), and examination (indication, finding type) characteristics. PPV3 (positive predictive value for biopsies performed) was calculated overall and according to category 4 subdivision. The χ 2 test was used to test for significant associations. Results Of 1 309 950 diagnostic mammograms, 125 447 (9.6%) were category 4, of which 33.3% (41 841 of 125 447) were subdivided. Subdivision utilization rates were higher (P < .001) in practices that were community, suburban, or in the West; for examination indication of prior history of breast cancer; and for the imaging finding of architectural distortion. Of 41 841 category 4 subdivided examinations, 4A constituted 55.6% (23 258 of 41 841) of the examinations; 4B, 31.8% (13 302 of 41 841) of the examinations; and 4C, 12.6% (5281 of 41 841) of the examinations. Pathologic outcomes were available in 91 563 examinations, and overall category 4 PPV3 was 21.1% (19 285 of 91 563). There was a statistically significant difference in PPV3 according to category 4 subdivision (P < .001): The PPV of 4A was 7.6% (1274 of 16 784), that of 4B was 22% (2317 of 10 408), and that of 4C was 69.3% (2839 of 4099). Conclusion Although BI-RADS suggests their use, subdivisions were utilized in the minority (33.3% [41 841 of 125 447]) of category 4 diagnostic mammograms, with variability based on facility and examination characteristics. When subdivisions were used, PPV3s were in BI-RADS-specified malignancy ranges. This

  5. Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan.

    PubMed

    Asada, Y; Suzuki, S; Minami, K; Shirakawa, S

    2014-03-01

    Diagnostic reference levels (DRLs) for mammography have yet to be created in Japan. A national questionnaire investigation into radiographic conditions in Japan was carried out for the purpose of creating DRLs. Items investigated included the following: tube voltage; tube current; current-time product; source-image distance; craniocaudal view; automatic exposure control (AEC) settings; name of mammography unit; image receptor system (computed radiography (CR), flat panel detector (FPD), or film/screen (F/S)); and supported or unsupported monitor diagnosis (including monitor resolution). Estimation of the mean glandular dose (MGD) for mammography was performed and compared with previous investigations. The MGD was 1.58(0.48) mGy, which did not significantly differ from a 2007 investigation. In relation to image receptors, although no difference in average MGD values was observed between CR and FPD systems, F/S systems had a significantly decreased value compared to both CR and FPDs. Concerning digital systems (FPDs), the MGD value of the direct conversion system was significantly higher than the indirect conversion system. No significant difference in MGD value was evident concerning type of monitor diagnosis for either the CR or the FPD digital systems; however, hard copies were used more often in CR. No significant difference in the MGD value was found in relation to monitor resolution. This report suggests ways to lower the doses patients undergoing mammography receive in Japan, and serves as reference data for 4.2 cm compressed breast tissue of 50% composition DRLs. Furthermore, our findings suggest that further optimisation of FPD settings can promote a reduction in the MGD value.

  6. Potential Cost Savings of Contrast-Enhanced Digital Mammography.

    PubMed

    Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A

    2017-06-01

    The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.

  7. Transition from film to digital mammography: impact for breast cancer screening through the national breast and cervical cancer early detection program.

    PubMed

    van Ravesteyn, Nicolien T; van Lier, Lisanne; Schechter, Clyde B; Ekwueme, Donatus U; Royalty, Janet; Miller, Jacqueline W; Near, Aimee M; Cronin, Kathleen A; Heijnsdijk, Eveline A M; Mandelblatt, Jeanne S; de Koning, Harry J

    2015-05-01

    The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40-64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]); costs (for screening and diagnostics); and number of women reached. NBCCEDP 2010 data and data representative of the program's target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. The models predicted 8.0-8.3 LYG per 1,000 film screens for black women, 5.9-7.5 for white women, and 4.0-4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%-4%), but had higher costs (34%-35%). Assuming a fixed budget, 25%-26% fewer women could be served, resulting in 22%-24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%-13% increase by only including biennial screening. Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. Copyright © 2015 American Journal of Preventive Medicine. All rights reserved.

  8. Mammography use and its demographic correlates among women in South Korea.

    PubMed

    Suh, Eunyoung E; Park, Sunhee

    2009-06-01

    This study aimed to investigate the mammography rate and its demographic correlates among Korean women in order to provide basic understanding of factors related to the performance of mammography as a method of breast cancer screening. A descriptive secondary analysis was conducted using a national data set from the Korean National Health and Nutrition Examination Survey (KNHNES III) in South Korea. A total number of 2,602 women over 40 years of age were chosen for the analysis. Main research variables included the use of mammography, monthly income, residential area, age, marriage, education, insurance, smoking habits, drinking habits, job type, current health status, and other cancer screening results. Only 30.59% of women adhered to the national guidelines. Monthly income, age, education, insurance, and smoking habits had statistically significant effects on breast cancer screening performance. The demographic correlates of the performance of mammography highlight the fact that not all Korean women, at this stage, are in a socioeconomic or societal position to undergo biannual mammography screening. Targeted and tailored nursing intervention should be implemented in middle- and senior-aged women who lack the ability to access medical resources in South Korea. This will make it possible for marginalized women to utilize cancer screening tests and in turn promote their health.

  9. Transition From Film to Digital Mammography

    PubMed Central

    van Ravesteyn, Nicolien T.; van Lier, Lisanne; Schechter, Clyde B.; Ekwueme, Donatus U.; Royalty, Janet; Miller, Jacqueline W.; Near, Aimee M.; Cronin, Kathleen A.; Heijnsdijk, Eveline A.M.; Mandelblatt, Jeanne S.; de Koning, Harry J.

    2015-01-01

    Introduction The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40–64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]), costs (for screening and diagnostics), and number of women reached. Methods NBCCEDP 2010 data and data representative of the program’s target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. Results The models predicted 8.0–8.3 LYG per 1,000 film screens for black women, 5.9–7.5 for white women, and 4.0–4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%–4%), but had higher costs (34%–35%). Assuming a fixed budget, 25%–26% fewer women could be served, resulting in 22%–24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%–13% increase by only including biennial screening. Conclusions Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. PMID:25891052

  10. Mammography

    MedlinePlus

    ... Prior Mammograms Helps Radiologists Detect Breast Cancer MammographySavesLives.org A general information resource on breast imaging from ... doctors: Breast Density and Breast Cancer Screening RTAnswers.org Radiation Therapy for Breast Cancer MedLinePlus Mammography top ...

  11. The Influence of Breast Self-Examination on Subsequent Mammography Participation

    PubMed Central

    Jelinski, Susan E.; Maxwell, Colleen J.; Onysko, Jay; Bancej, Christina M.

    2005-01-01

    Objectives. We evaluated whether breast self-examination (BSE) influences subsequent mammography participation. Methods. We evaluated associations between BSE and subsequent mammography participation, adjusting for baseline screening behaviors and sociodemographic, health, and lifestyle characteristics, among women aged 40 years and older using data from the longitudinal Canadian National Population Health Survey. Results. Regular performance of BSE at baseline was not associated with receipt of a recent mammogram at follow-up among all women (adjusted odds ratio [OR]=1.01; 95% confidence interval [CI]= 0.75, 1.35) or with mammography uptake among the subgroup of women reporting never use at baseline (adjusted OR=0.78; 95% CI=0.50, 1.22). Conclusions. The lack of association between performance of BSE and subsequent mammography participation suggests that not recommending BSE is unlikely to influence mammography participation. PMID:15727985

  12. Current Realities of Delivering Mammography Services in the Community: Do Challenges with Staffing and Scheduling Exist?

    PubMed Central

    D'Orsi, Carl; Tu, Shin-Ping; Nakano, Connie; Carney, Patricia A.; Abraham, Linn A.; Taplin, Stephen H.; Hendrick, R. Edward; Cutter, Gary R.; Berns, Eric; Barlow, William E.; Elmore, Joann G.

    2011-01-01

    PURPOSE To evaluate the current (2001–2002) capacity of community-based mammography facilities to deliver screening and diagnostic services in the United States. MATERIALS AND METHODS Institutional review board approvals and patient consent were obtained. A mailed survey was sent to 53 eligible mammography facilities in three states (Washington, New Hampshire, and Colorado). Survey questions assessed equipment and staffing availability, as well as appointment waiting times for screening and diagnostic mammography services. Criterion-related content and construct validity were obtained first by means of a national advisory committee of academic, scientific, and clinical colleagues in mammography that reviewed literature on existing surveys and second by pilot testing a series of draft surveys among community mammography facilities not inclusive of the study facilities. The final survey results were independently double entered into a relational database with programmed data checks. The data were sent encrypted by means of file transfer protocol to a central analytical center at Group Health Cooperative. A two-sided P value with α = .05 was considered to show statistical significance in all analyses. RESULTS Forty-five of 53 eligible mammography facilities (85%) returned the survey. Shortages of radiologists relative to the mammographic volume were found in 44% of mammography facilities overall, with shortages of radiologists higher in not-for-profit versus for-profit facilities (60% vs 28% reported). Shortages of Mammography Quality Standards Act–qualified technologists were reported by 20% of facilities, with 46% reporting some level of difficulty in maintaining qualified technologists. Waiting times for diagnostic mammography ranged from less than 1 week to 4 weeks, with 85% performed within 1 week. Waiting times for screening mammography ranged from less than 1 week to 8 weeks, with 59% performed between 1 week and 4 weeks. Waiting times for both diagnostic

  13. Audit of mammography requests in Abakaliki, South-East Nigeria.

    PubMed

    Eni, U E; Ekwedigwe, K C; Sunday-Adeoye, I; Daniyan, Abc; Isikhuemen, M E

    2017-03-07

    Breast cancer is the leading cancer in women in both developed and developing countries. Screening mammography detects breast cancer even before a lump can be palpated, with better prognosis. The introduction of mammographic technique for screening breast cancer, despite its importance, has been slow to adopt and virtually non-existent in many parts of Sub-Saharan Africa including Nigeria. For this reason, the indications of mammography have not been well defined in our setting. The aim of this study was to audit our mammography requests, with a view to improving its application in our setting. This is a descriptive study carried out on 69 female patients who had mammography at the National Obstetric Fistula Centre, Abakaliki, from January 2014 to December 2015. Findings on clinical examination were entered in a proforma. Mammography was performed in craniocaudal and mediolateral views using the Lorad M-IV (film-screen) mammography machine. Data was analysed using the Statistical Package for Social Sciences (SPSS) version 21. All 69 patients were females. Their mean age was 42.1 ± 11 years. Majority of the patients (69.6%) were between 30 and 49 years. The commonest indication for mammography was breast lump which was found in 46 patients (66.7%). Breast pain was present in 36 (52.2%) of patients. The different Breast Imaging Reporting and Data System (BIRADS) categories were BIRADS 0: 20 (28.99%), BIRADS 1: 8 (11.59%), BIRADS 2: 9 (13.04%), BIRADS 3: 4 (5.8%), BIRADS 4: 19 (27.54%) and BIRADS 5: 9 (13.04%). Diagnostic mammography remains the commonest indication for mammography in our setting. Public awareness, poverty reduction and ready availability of mammography facilities are required to improve screening mammography in our setting.

  14. Conflicting national recommendations and the use of screening mammography: does the physician's recommendation matter?

    PubMed

    Taplin, S H; Urban, N; Taylor, V M; Savarino, J

    1997-01-01

    This study evaluated whether women's perceptions of the conflicting recommendations for breast cancer screening were associated with decreased use of mammography. We conducted a random-digit-dial telephone survey of 1024 women in four communities of western Washington State. In addition to collecting data for demographics, beliefs about mammography, and insurance coverage, we inquired whether the respondents were aware of any conflicting recommendations about when to begin or how frequently to perform screening mammography, whether their physicians had recommended a mammogram, and whether they were likely to do what their physicians recommended. After grouping women according to whether they perceived conflicting recommendations, we used chi-square statistics to compare the distribution of proportions of women by age, race, household income, education, and insurance coverage. To estimate the odds of their having a mammogram in the previous 2 years (yes or no), we used multivariate logistic regression and included the above variables as covariates. Sixty-two percent of eligible women completed the survey, and 49 percent (479 of 985) perceived conflicting recommendations. The association between perceiving conflict and mammography use was not significant. Eighty-three percent of women who perceived conflicting recommendations reported being more comfortable using their own judgment about getting the procedure. After controlling for whether women perceived conflicting recommendations and all other factors, women who said they followed their physician's advice but did not recall their physician recommending mammography were 71 percent less likely to have received a recent mammogram than were women who reported their physician did recommend it (odds ratio 0.29, confidence interval 0.16-0.51). The conflicting recommendations surrounding breast cancer screening are not influencing women's choices about mammography. The physician recommendation and women's self

  15. A national cross-sectional study of adherence to timely mammography use in Malta.

    PubMed

    Marmarà, Danika; Marmarà, Vincent; Hubbard, Gill

    2018-03-27

    Routine mammography improves survival. To achieve health benefits, women must attend breast screening regularly at recommended time intervals. Maltese women are routinely invited to undergo mammography at three-year intervals at an organized breast screening programme (MBSP) or can opt to attend a private clinic. Previous research shows that health beliefs, particularly perceived barriers, were the most significant predictors of uptake to the first MBSP invitation. Whether these beliefs and other factors are predictive of adherence with recommended time intervals for mammography at organized or private screening in Malta is unknown. For the first time, this paper explores the predictors for Maltese women screened within or exceeding the recommended three-year frequency in organized or private screening in Malta. Information was obtained from a cross-sectional survey of 404 women, aged 50 to 60 years at the time of their first MBSP invitation, where women's characteristics, knowledge, health beliefs and illness perceptions were compared. The main variable of interest was women's mammography attendance within a three-year interval (ADHERENT) or exceeding three years (NON-ADHERENT). Data were analysed using descriptive statistics, chi-square test, Mann Whitney test, Independent Samples t-test and Shapiro Wilk test. At the time of the survey, 80.2% (n = 324) had been screened within three years (ADHERENT), 5.9% (n = 24) had exceeded the three-year frequency (NON-ADHERENT) while 13.9% (n = 56) never had a mammogram. No significant associations were found between ADHERENT or NON-ADHERENT women in relation to sociodemographic or health status variables (p > 0.05). Knowledge of screening frequency was significantly associated with women's mammography adherence (χ2 = 5.5, p = 0.020). Health beliefs were the strongest significant predictors to describe the variance between ADHERENT and NON-ADHERENT screeners. When Mann Whitney test and Independent

  16. Getting started with protocol for quality assurance of digital mammography in the clinical centre of Montenegro.

    PubMed

    Ivanovic, S; Bosmans, H; Mijovic, S

    2015-07-01

    The purpose of this work is (i) to work out a test procedure for quality assurance (QA) in digital mammography with newly released test equipment, including the MagicMax mam multimeter (IBA, Germany) and the anthropomorphic tissue equivalent phantom Mammo AT (IBA, Germany), and (ii) to determine whether a first digital computer radiography (CR) system in Montenegro meets the current European standards. Tested parameters were tube output (µGy mAs(-1)) and output rate (mGy s(-1)), reproducibility and accuracy of tube voltage, half value layer, reproducibility and accuracy of the AEC system, exposure control steps, image receptor's response function, image quality and printer stability test. The evaluated dosimetric quantity is the average glandular dose (AGD) as evaluated from PMMA slabs simulating breast tissue. The main findings are that QA can be organised in Montenegro. (1) All measured parameters are within the range described in European protocols except the tube voltage which deviated more than ± 1 kV. The automatic determination of the HVL was satisfactorily. AGD ranged from 0.66 to 7.02 mGy for PMMA thicknesses from 20 to 70 mm, and is in accordance with literature data. (2) The image quality score as obtained with the anthropomorphic tissue equivalent phantom Mammo AT for the CR system was similar to findings on the authors' conventional screen-film mammography. (3) In clinical practice the mammograms are printed. The CR reader produces images with a pixel size of 43.75 µm, which is compatible with the laser printer (39 µm laser spot spacing). The image processing algorithm embedded in the reader successfully processes mammograms with desirable image brightness and contrast in the printed image. The authors conclude that this first digital mammography system seems a good candidate for breast cancer screening applications. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Fixed-facility workplace screening mammography.

    PubMed

    Reynolds, H E; Larkin, G N; Jackson, V P; Hawes, D R

    1997-02-01

    Potential barriers to compliance with screening mammography guidelines include the cost and inconvenience involved with undergoing the procedure. Workplace screening with mobile mammography is one possible approach to the convenience barrier. However, fixed-facility workplace screening is a viable alternative for any company with a large workforce in one location. This paper describes our initial experience with one such fixed facility. The facility was a cooperative venture by a large pharmaceutical company and an academic radiology department to provide convenient, no-cost (to the patient) screening mammography to employees, dependents, and retirees more than 40 years old. The pharmaceutical company built the facility within its corporate headquarters and the academic radiology department provided the equipment and personnel. The company was billed a fixed cost per examination. In the first 22 months of operation, 4210 (of 4559 scheduled) screening mammograms were obtained. The mean age of the population was 53 years old. Ninety percent of the screening mammograms were interpreted as negative or benign; 10% required additional workup. Of the screened population, 62 biopsies were recommended and 60 were performed. Of these, 42 were benign and 18 malignant. The cancer detection rate was 4.3 per 1000 (0.43%). At the time of diagnosis, six patients were stage 0, 10 patients were stage I, one patient was stage II, and one patient was stage III. Eleven of the 18 patients had minimal cancers. Of the patients who completed a satisfaction survey, 97% percent expressed a high degree of satisfaction with the screening process and stated they would use the facility in the future. A fixed facility for workplace screening mammography is a viable way to provide nearly barrier-free access to high-quality mammography. Patient acceptance is high.

  18. The radiation metrology network related to the field of mammography: implementation and uncertainty analysis of the calibration system

    NASA Astrophysics Data System (ADS)

    Peixoto, J. G. P.; de Almeida, C. E.

    2001-09-01

    It is recognized by the international guidelines that it is necessary to offer calibration services for mammography beams in order to improve the quality of clinical diagnosis. Major efforts have been made by several laboratories in order to establish an appropriate and traceable calibration infrastructure and to provide the basis for a quality control programme in mammography. The contribution of the radiation metrology network to the users of mammography is reviewed in this work. Also steps required for the implementation of a mammography calibration system using a constant potential x-ray and a clinical mammography x-ray machine are presented. The various qualities of mammography radiation discussed in this work are in accordance with the IEC 61674 and the AAPM recommendations. They are at present available at several primary standard dosimetry laboratories (PSDLs), namely the PTB, NIST and BEV and a few secondary standard dosimetry laboratories (SSDLs) such as at the University of Wisconsin and at the IAEA's SSDL. We discuss the uncertainties involved in all steps of the calibration chain in accord with the ISO recommendations.

  19. [Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer--comparison with film-screen mammography].

    PubMed

    Kitahama, H

    1991-05-25

    The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area = 0.91) was better than that on film-screen mammography (ROC area = 0.88) (p less than 0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study.

  20. Family/friend recommendations and mammography intentions: the roles of perceived mammography norms and support

    PubMed Central

    Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.

    2015-01-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [−0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. PMID:26324395

  1. National Performance Benchmarks for Modern Screening Digital Mammography: Update from the Breast Cancer Surveillance Consortium.

    PubMed

    Lehman, Constance D; Arao, Robert F; Sprague, Brian L; Lee, Janie M; Buist, Diana S M; Kerlikowske, Karla; Henderson, Louise M; Onega, Tracy; Tosteson, Anna N A; Rauscher, Garth H; Miglioretti, Diana L

    2017-04-01

    Purpose To establish performance benchmarks for modern screening digital mammography and assess performance trends over time in U.S. community practice. Materials and Methods This HIPAA-compliant, institutional review board-approved study measured the performance of digital screening mammography interpreted by 359 radiologists across 95 facilities in six Breast Cancer Surveillance Consortium (BCSC) registries. The study included 1 682 504 digital screening mammograms performed between 2007 and 2013 in 792 808 women. Performance measures were calculated according to the American College of Radiology Breast Imaging Reporting and Data System, 5th edition, and were compared with published benchmarks by the BCSC, the National Mammography Database, and performance recommendations by expert opinion. Benchmarks were derived from the distribution of performance metrics across radiologists and were presented as 50th (median), 10th, 25th, 75th, and 90th percentiles, with graphic presentations using smoothed curves. Results Mean screening performance measures were as follows: abnormal interpretation rate (AIR), 11.6 (95% confidence interval [CI]: 11.5, 11.6); cancers detected per 1000 screens, or cancer detection rate (CDR), 5.1 (95% CI: 5.0, 5.2); sensitivity, 86.9% (95% CI: 86.3%, 87.6%); specificity, 88.9% (95% CI: 88.8%, 88.9%); false-negative rate per 1000 screens, 0.8 (95% CI: 0.7, 0.8); positive predictive value (PPV) 1, 4.4% (95% CI: 4.3%, 4.5%); PPV2, 25.6% (95% CI: 25.1%, 26.1%); PPV3, 28.6% (95% CI: 28.0%, 29.3%); cancers stage 0 or 1, 76.9%; minimal cancers, 57.7%; and node-negative invasive cancers, 79.4%. Recommended CDRs were achieved by 92.1% of radiologists in community practice, and 97.1% achieved recommended ranges for sensitivity. Only 59.0% of radiologists achieved recommended AIRs, and only 63.0% achieved recommended levels of specificity. Conclusion The majority of radiologists in the BCSC surpass cancer detection recommendations for screening

  2. [Prevalence in the performance of mammographies in Spain: Analysis by Communities 2006-2014 and influencing factors].

    PubMed

    Carmona-Torres, Juan Manuel; Cobo-Cuenca, Ana Isabel; Martín-Espinosa, Noelia María; Piriz-Campos, Rosa María; Laredo-Aguilera, José Alberto; Rodríguez-Borrego, María Aurora

    2018-04-01

    To determine the frequency of the performance of mammography with preventive purpose of the screening of breast cancer in Spanish women, the evolution between the years 2006-2014, the sociodemographic profile of the women who undergo the mammography and to analyze the factors that influence in their adhesion. Transversal study. Spain. A total of 53.628 women over 15 years old that are surveyed in the National Health Survey in Spain 2006 and 2011/12 and the European Health Survey in Spain 2009 and 2014. The following variables were used: mammography, frequency of mammography performance and the reason for the realization, as well as sociodemographic variables. Social class was obtained from the last occupation of the main family supporter. A logistic regression analysis was performed with sociodemographic variables. The prevalence of mammography has been increasing from 2006 to 2014, and also for the reason that the participants had received a letter, they were telephoned or offered in their Health Center to undergo this test. There are significant differences in the performance of mammography in the different autonomous communities. Performing mammography has increased significantly from 2006 to 2014, although there are still differences between autonomous communities, with Ceuta and Melilla being the least percentage of performed mammography. The factors that are related to greater performed mammography are: higher educational level, higher social class, married civil status, Spanish nationality and age. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  3. A screening mammography program. Staying alive and making it work.

    PubMed

    Monsees, B S; Destouet, J M

    1992-01-01

    The success of a mammography screening program requires thorough planning. A dependably high volume and a streamlined efficient operation are essential to survival of the program. Factors that warrant consideration prior to designing such a program include the following: Distinction between screening and diagnostic mammography examinations. Selection of a site that will meet the needs of the community and yet provide a consistently high volume. Low examination cost for screening mammography coupled with a detailed financial analysis and reappraisal on an ongoing basis. A customized marketing program that incorporates methods to increase awareness, compliance, and utilization by women and referring physicians. Well-trained, efficient, and dedicated personnel. An operation that is designed for rapid throughput and expeditious patient flow. An efficient plan for film handling, interpretation, reporting, and storage. Timely communication of examination results. A reliable mechanism for follow-up evaluation and outcome data collection. Establishment of a consistent and reliable quality assurance program and the production of high quality mammograms.

  4. Screening Mammography and Digital Breast Tomosynthesis: Utilization Updates.

    PubMed

    Boroumand, Gilda; Teberian, Ida; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-05-01

    There have been many recent developments in breast imaging, including the 2009 revision of the U.S. Preventive Services Task Force's breast cancer screening guidelines and the approval of digital breast tomosynthesis (DBT) for clinical use in 2011. The objective of this study is to evaluate screening mammography utilization trends among the Medicare population from 2005 to 2015 and examine the volume of DBT studies performed in 2015, the first year for which procedural billing codes for DBT are available. We reviewed national Medicare Part B Physician/Supplier Procedure Summary master files from 2005 to 2015, to determine the annual utilization rate of screening mammography on the basis of procedure codes used for film-screen and digital screening mammography. We also used the Physician/Supplier Procedure Summary master files to determine the volume of screening and diagnostic DBT studies performed in 2015. The utilization rate of screening mammography per 1000 women in the Medicare fee-for-service population increased gradually every year, from 311.5 examinations in 2005 to a peak of 322.9 examinations in 2009, representing a compound annual growth rate of 0.9%. In 2010, the utilization rate abruptly decreased by 4.3% to 309.2 examinations, and it has not since recovered to pre-2010 levels. In 2015, 18.9% of screening and 16.2% of diagnostic digital mammography examinations included DBT as an add-on procedure. In contrast to the annual increase in screening mammography utilization from 2005 to 2009, an abrupt sustained decline in screening occurred beginning in 2010, coinciding with the release of U.S. Preventive Services Task Force recommendations. DBT utilization was somewhat limited in 2015, occurring in conjunction with less than 20% of digital mammography examinations.

  5. Family/friend recommendations and mammography intentions: the roles of perceived mammography norms and support.

    PubMed

    Molina, Yamile; Ornelas, India J; Doty, Sarah L; Bishop, Sonia; Beresford, Shirley A A; Coronado, Gloria D

    2015-10-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [-0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Response costs of mammography adherence: Iranian women's perceptions.

    PubMed

    Khodayarian, Mahsa; Mazloomi-Mahmoodabad, Seyed Saied; Lamyian, Minoor; Morowatisharifabad, Mohammad Ali; Tavangar, Hossein

    2016-01-01

    Mammography as the most common secondary prevention method has known to be helpful in detecting breast cancer at the early stages. Low level of participation among women toward mammography uptake due to cultural beliefs is a great concern. This study aimed at exploring the perceptions of women about response costs of mammography adherence (MA) in Yazd, Iran. A qualitative study using semi-structured interviews was performed. Fourteen women,one oncology nurse, and a breast cancer survivor were purposefully interviewed. Interviews were transcribed verbatim and analyzed by directed content analysis method based on protection motivation theory (PMT). One main theme was emerged from the analysis namely called "response costs".Two main categories were also emerged from the data; (1) psychological barriers with six subcategories including "embarrassment," "worry about being diagnosed with cancer," "preoccupation with underlying disease," "misconception about mammography," "need for an accompanying person," and "internalizing the experiences of the others," and (2) maladaptive coping modes which encompassed three subcategories: "religious faith," "fatalism," and"avoidance and denial." Useful information was provided about the response costs of mammography utilization based on the perceptions of women. Cognitive barriers may be decreased by conducting modifications in women's awareness and attitude toward MA as well as changing the national health system infrastructures. Incorporating religious and cultural belief systems into MA educational programs through motivational messages is recommended.

  7. Experience with a proposed teleradiology system for digital mammography

    NASA Astrophysics Data System (ADS)

    Saulnier, Emilie T.; Mitchell, Robert J.; Abdel-Malek, Aiman A.; Dudding, Kathryn E.

    1995-05-01

    Teleradiology offers significant improvement in efficiency and effectiveness over current practices in traditional film/screen-based diagnosis. In the context of digital mammography, the increasing number of women who need to be screened for breast cancer, including those in remote rural regions, make the advantages of teleradiology especially attractive for digital mammography. At the same time, the size and resolution of digital mammograms are among the most challenging to support in a cost effective teleradiology system. This paper describes a teleradiology architecture developed for use with digital mammography by GE Corporate Research and Development in collaboration with Massachusetts General Hospital under National Cancer Institute (NCI/NIH) grant number R01 CA60246-01. Experience with a testbed prototype is described. The telemammography architecture is intended to consist of a main mammography diagnostic site serving several remote screening sites. As patient exams become available, they are forwarded by an image server to the diagnostic site over a WAN communications link. A radiologist at the diagnostic site views a patient exam as it arrives, interprets it, and then relays a report back to the technician at the remote site. A secondary future scenario consists of mobile units which forward images to a remote site, which then forwards them to the main diagnostic site. The testbed architecture is based on the Digital Imaging and Communications in Medicine (DICOM) standard, created by the American College of Radiology (ACR) and National Electrical Manufacturers Association (NEMA). A specification of vendor-independent data formats and data transfer services for digital medical images, DICOM specifies a protocol suite starting at the application layer downward, including the TCP/IP layers. The current DICOM definition does not provide an information element that is specifically tailored to mammography, so we have used the DICOM secondary capture data format

  8. Mammography Patient Information at Hospital Websites: Most Neither Comprehensible Nor Guideline Supported.

    PubMed

    Sadigh, Gelareh; Singh, Kush; Gilbert, Kirven; Khan, Ramsha; Duszak, Abigail M; Duszak, Richard

    2016-11-01

    Ongoing controversy regarding screening mammography guidelines has created confusion for many patients. Given recommendations that patient educational material be prepared at or below the 7th grade reading level of average Americans, the purpose of this study was to assess the readability of online mammography information offered by hospitals nationwide. During 2015, online mammography patient educational materials were identified for all Medicare-recognized hospitals nationwide for which screening mammography metrics were publicly available. Patient educational materials were assessed using six validated readability score algorithms. All references to official screening guidelines were captured. Of 4105 hospitals nationwide, 3252 had websites and confirmable screening mammography services. Of those, 1753 (54%) offered mammography information material online. Only 919 (28%) referenced any professional society guidelines. After excluding information not formatted in HTML and shorter than 100 words (to improve algorithm reliability), 1524 hospital mammography webpages were assessed for grade level scores. Nationally, the mean of each readability score for all hospitals varied between the 10th and 14th grade levels, all higher than the recommended 7th grade level (p < 0.001). At the individual hospital level, only 14 hospitals (0.4%) had mean scores at or below the 7th grade level. Of U.S. hospitals that offer screening mammography and have websites, only 54% provide online mammography educational material. Of those, only 0.4% present information at a reading level comprehensible to average Americans, and only 28% offer specific information to help patients reconcile conflicting guidelines. Health systems offering mammography should strive to better meet women's health information and literacy needs.

  9. Image quality, threshold contrast and mean glandular dose in CR mammography

    NASA Astrophysics Data System (ADS)

    Jakubiak, R. R.; Gamba, H. R.; Neves, E. B.; Peixoto, J. E.

    2013-09-01

    In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both

  10. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    PubMed

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  11. Mammography Use Among Medicare Beneficiaries After Elimination of Cost Sharing.

    PubMed

    Sabatino, Susan A; Thompson, Trevor D; Guy, Gery P; de Moor, Janet S; Tangka, Florence K

    2016-04-01

    We examined mammography use before and after Medicare eliminated cost sharing for screening mammography in January 2011. Using National Health Interview Survey data, we examined changes in mammography use between 2010 and 2013 among Medicare beneficiaries aged 65-74 years. Logistic regression and predictive margins were used to examine changes in use after adjusting for covariates. In 2013, 74.7% of women reported a mammogram within 2 years, a 3.5 percentage point increase (95% confidence interval, -0.3, 7.2) compared with 2010. Increases occurred among women aged 65-69 years, unmarried women, and women with usual sources of care and 2-5 physician visits in the prior year. After adjustment, mammography use increased in 2013 versus 2010 (74.8% vs. 71.3%, P=0.039). Interactions between year and income, insurance, race, or ethnicity were not significant. There was a modest increase in mammography use from 2010 to 2013 among Medicare beneficiaries aged 65-74 years, possibly consistent with an effect of eliminating Medicare cost sharing during this time. Findings suggest that eliminating cost sharing might increase use of recommended screening services.

  12. CR digital mammography: an affordable entry.

    PubMed

    Fischer, Cathy

    2006-01-01

    CR full-field digital mammography (FFDM) has been used extensively in other countries, and it was one of the 4 digital mammography technologies employed in the Digital Mammographic Imaging Screening Trial. Affordability and easy integration with pre-existing mammography systems makes CR FFDM an attractive way to secure the advantages of filmless mammography imaging. CR mammography is true digital mammography--it is merely a different way of acquiring the image. The FDA has recently approved the first CR FFDM system for sale in the United States. At Gundersen Lutheran Health System (La Crosse, Wisconsin), CR FFDM is the most practical technology for realizing the potential everyday clinical benefits of filmless mammography imaging.

  13. A comparison of the performance of modern screen-film and digital mammography systems.

    PubMed

    Monnin, P; Gutierrez, D; Bulling, S; Lepori, D; Valley, J-F; Verdun, F R

    2005-06-07

    This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.

  14. Personalizing mammography by breast density and other risk factors for breast cancer: analysis of health benefits and cost-effectiveness.

    PubMed

    Schousboe, John T; Kerlikowske, Karla; Loh, Andrew; Cummings, Steven R

    2011-07-05

    Current guidelines recommend mammography every 1 or 2 years starting at age 40 or 50 years, regardless of individual risk for breast cancer. To estimate the cost-effectiveness of mammography by age, breast density, history of breast biopsy, family history of breast cancer, and screening interval. Markov microsimulation model. Surveillance, Epidemiology, and End Results program, Breast Cancer Surveillance Consortium, and the medical literature. U.S. women aged 40 to 49, 50 to 59, 60 to 69, and 70 to 79 years with initial mammography at age 40 years and breast density of Breast Imaging Reporting and Data System (BI-RADS) categories 1 to 4. Lifetime. National health payer. Mammography annually, biennially, or every 3 to 4 years or no mammography. Costs per quality-adjusted life-year (QALY) gained and number of women screened over 10 years to prevent 1 death from breast cancer. Biennial mammography cost less than $100,000 per QALY gained for women aged 40 to 79 years with BI-RADS category 3 or 4 breast density or aged 50 to 69 years with category 2 density; women aged 60 to 79 years with category 1 density and either a family history of breast cancer or a previous breast biopsy; and all women aged 40 to 79 years with both a family history of breast cancer and a previous breast biopsy, regardless of breast density. Biennial mammography cost less than $50,000 per QALY gained for women aged 40 to 49 years with category 3 or 4 breast density and either a previous breast biopsy or a family history of breast cancer. Annual mammography was not cost-effective for any group, regardless of age or breast density. Mammography is expensive if the disutility of false-positive mammography results and the costs of detecting nonprogressive and nonlethal invasive cancer are considered. Results are not applicable to carriers of BRCA1 or BRCA2 mutations. Mammography screening should be personalized on the basis of a woman's age, breast density, history of breast biopsy, family history of

  15. Radiation-Induced Breast Cancer Incidence and Mortality From Digital Mammography Screening: A Modeling Study.

    PubMed

    Miglioretti, Diana L; Lange, Jane; van den Broek, Jeroen J; Lee, Christoph I; van Ravesteyn, Nicolien T; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J; Melnikow, Joy; de Koning, Harry J; Hubbard, Rebecca A

    2016-02-16

    Estimates of risk for radiation-induced breast cancer from mammography screening have not considered variation in dose exposure or diagnostic work-up after abnormal screening results. To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening while considering exposure from screening and diagnostic mammography and dose variation among women. 2 simulation-modeling approaches. U.S. population. Women aged 40 to 74 years. Annual or biennial digital mammography screening from age 40, 45, or 50 years until age 74 years. Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality (harms) per 100,000 women screened. Annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancer cases (95% CI, 88 to 178) leading to 16 deaths (CI, 11 to 23), relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 cases of radiation-induced breast cancer leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete examination (8% of population) were projected to have greater radiation-induced breast cancer risk (266 cancer cases and 35 deaths per 100,000 women) than other women (113 cancer cases and 15 deaths per 100,000 women). Biennial screening starting at age 50 years reduced risk for radiation-induced cancer 5-fold. Life-years lost from radiation-induced breast cancer could not be estimated. Radiation-induced breast cancer incidence and mortality from digital mammography screening are affected by dose variability from screening, resultant diagnostic work-up, initiation age, and screening frequency. Women with large breasts may have a greater risk for radiation-induced breast cancer. Agency for Healthcare Research and Quality, U.S. Preventive Services Task Force, National Cancer Institute.

  16. Cost-effectiveness analysis of mammography and clinical breast examination strategies

    PubMed Central

    Ahern, Charlotte Hsieh; Shen, Yu

    2009-01-01

    Purpose Breast cancer screening by mammography and clinical breast exam are commonly used for early tumor detection. Previous cost-effectiveness studies considered mammography alone or did not account for all relevant costs. In this study, we assessed the cost-effectiveness of screening schedules recommended by three major cancer organizations and compared them with alternative strategies. We considered costs of screening examinations, subsequent work-up, biopsy, and treatment interventions after diagnosis. Methods We used a microsimulation model to generate women’s life histories, and assessed screening and treatment impacts on survival. Using statistical models, we accounted for age-specific incidence, preclinical disease duration, and age-specific sensitivity and specificity for each screening modality. The outcomes of interest were quality-adjusted life years (QALYs) saved and total costs with a 3% annual discount rate. Incremental cost-effectiveness ratios were used to compare strategies. Sensitivity analyses were performed by varying some of the assumptions. Results Compared to guidelines from the National Cancer Institute and the U.S. Preventive Services Task Force, alternative strategies were more efficient. Mammography and clinical breast exam in alternating years from ages 40 to 79 was a cost-effective alternative compared to the guidelines, costing $35,500 per QALY saved compared with no screening. The American Cancer Society guideline was the most effective and the most expensive, costing over $680,000 for an added QALY compared to the above alternative. Conclusion Screening strategies with lower costs and benefits comparable to those currently recommended should be considered for implementation in practice and for future guidelines. PMID:19258473

  17. The quality of tumor size assessment by contrast-enhanced spectral mammography and the benefit of additional breast MRI.

    PubMed

    Lobbes, Marc B I; Lalji, Ulrich C; Nelemans, Patty J; Houben, Ivo; Smidt, Marjolein L; Heuts, Esther; de Vries, Bart; Wildberger, Joachim E; Beets-Tan, Regina G

    2015-01-01

    Background - Contrast-enhanced spectral mammography (CESM) is a promising new breast imaging modality that is superior to conventional mammography for breast cancer detection. We aimed to evaluate correlation and agreement of tumor size measurements using CESM. As additional analysis, we evaluated whether measurements using an additional breast MRI exam would yield more accurate results. Methods - Between January 1(st) 2013 and April 1(st) 2014, 87 consecutive breast cancer cases that underwent CESM were collected and data on maximum tumor size measurements were gathered. In 57 cases, tumor size measurements were also available for breast MRI. Histopathological results of the surgical specimen served as gold standard in all cases. Results - The Pearson's correlation coefficients (PCC) of CESM versus histopathology and breast MRI versus histopathology were all >0.9, p<0.0001. For the agreement between measurements, the mean difference between CESM and histopathology was 0.03 mm. The mean difference between breast MRI and histopathology was 2.12 mm. Using a 2x2 contingency table to assess the frequency distribution of a relevant size discrepancy of >1 cm between the two imaging modalities and histopathological results, we did not observe any advantage of performing an additional breast MRI after CESM in any of the cases. Conclusion - Quality of tumor size measurement using CESM is good and matches the quality of these measurement assessed by breast MRI. Additional measurements using breast MRI did not improve the quality of tumor size measurements.

  18. The Quality of Tumor Size Assessment by Contrast-Enhanced Spectral Mammography and the Benefit of Additional Breast MRI

    PubMed Central

    Lobbes, Marc B.I.; Lalji, Ulrich C.; Nelemans, Patty J.; Houben, Ivo; Smidt, Marjolein L.; Heuts, Esther; de Vries, Bart; Wildberger, Joachim E.; Beets-Tan, Regina G.

    2015-01-01

    Background - Contrast-enhanced spectral mammography (CESM) is a promising new breast imaging modality that is superior to conventional mammography for breast cancer detection. We aimed to evaluate correlation and agreement of tumor size measurements using CESM. As additional analysis, we evaluated whether measurements using an additional breast MRI exam would yield more accurate results. Methods - Between January 1st 2013 and April 1st 2014, 87 consecutive breast cancer cases that underwent CESM were collected and data on maximum tumor size measurements were gathered. In 57 cases, tumor size measurements were also available for breast MRI. Histopathological results of the surgical specimen served as gold standard in all cases. Results - The Pearson's correlation coefficients (PCC) of CESM versus histopathology and breast MRI versus histopathology were all >0.9, p<0.0001. For the agreement between measurements, the mean difference between CESM and histopathology was 0.03 mm. The mean difference between breast MRI and histopathology was 2.12 mm. Using a 2x2 contingency table to assess the frequency distribution of a relevant size discrepancy of >1 cm between the two imaging modalities and histopathological results, we did not observe any advantage of performing an additional breast MRI after CESM in any of the cases. Conclusion - Quality of tumor size measurement using CESM is good and matches the quality of these measurement assessed by breast MRI. Additional measurements using breast MRI did not improve the quality of tumor size measurements. PMID:25561979

  19. The U.S. Online News Coverage of Mammography Based on a Google News Search.

    PubMed

    Young Lin, Leng Leng; Rosenkrantz, Andrew B

    2017-12-01

    To characterize online news coverage relating to mammography, including articles' stance toward screening mammography. Google News was used to search U.S. news sites over a 9-year period (2006-2015) based on the search terms "mammography" and "mammogram." The top 100 search results were recorded. Identified articles were manually reviewed. The top 100 news articles were from the following sources: local news outlet (50%), national news outlet (24%), nonimaging medical source (13%), entertainment or culture news outlet (6%), business news outlet (4%), peer-reviewed journal (1%), and radiology news outlet (1%). Most common major themes were the screening mammography controversy (29%), description of a new breast imaging technology (23%), dense breasts (11%), and promotion of a public screening initiative (11%). For the most recent year, article stance toward screening mammography was 59%, favorable; 16%, unfavorable; and 25%, neutral. After 2010, there was an abrupt shift in articles' stances from neutral to both favorable and unfavorable. A wide range of online news sources addressed a range of issues related to mammography. National, rather than local, news sites were more likely to focus on the screening controversy and more likely to take an unfavorable view. The controversial United States Preventive Services Task Force guidelines may have influenced articles to take a stance on screening mammography. As such online news may impact public perception of the topic and thus potentially impact guideline adherence, radiologists are encouraged to maintain awareness of this online coverage and to support the online dissemination of reliable and accurate information. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. High dynamic range CMOS-based mammography detector for FFDM and DBT

    NASA Astrophysics Data System (ADS)

    Peters, Inge M.; Smit, Chiel; Miller, James J.; Lomako, Andrey

    2016-03-01

    Digital Breast Tomosynthesis (DBT) requires excellent image quality in a dynamic mode at very low dose levels while Full Field Digital Mammography (FFDM) is a static imaging modality that requires high saturation dose levels. These opposing requirements can only be met by a dynamic detector with a high dynamic range. This paper will discuss a wafer-scale CMOS-based mammography detector with 49.5 μm pixels and a CsI scintillator. Excellent image quality is obtained for FFDM as well as DBT applications, comparing favorably with a-Se detectors that dominate the X-ray mammography market today. The typical dynamic range of a mammography detector is not high enough to accommodate both the low noise and the high saturation dose requirements for DBT and FFDM applications, respectively. An approach based on gain switching does not provide the signal-to-noise benefits in the low-dose DBT conditions. The solution to this is to add frame summing functionality to the detector. In one X-ray pulse several image frames will be acquired and summed. The requirements to implement this into a detector are low noise levels, high frame rates and low lag performance, all of which are unique characteristics of CMOS detectors. Results are presented to prove that excellent image quality is achieved, using a single detector for both DBT as well as FFDM dose conditions. This method of frame summing gave the opportunity to optimize the detector noise and saturation level for DBT applications, to achieve high DQE level at low dose, without compromising the FFDM performance.

  1. MO-E-217A-01: Contrast-Enhanced Spectral Mammography - Physical Aspects and QA.

    PubMed

    Yaffe, M; Hill, M

    2012-06-01

    To describe the current state of dual energy contrast-enhanced digital mammography, to discuss those aspects of its operation that require evaluation or monitoring and to propose elements of a program for quality assurance of such systems. The principles of dual-energy contrast imaging will be discussed and tools and techniques for assessment of performance will be described. Many of the elements affecting image quality and dose performance in digital mammography (eg noise, system linearity, consistency of x-ray output and detector performance, artifacts) remain important. In addition, the ability to register images can influence the resultant image quality. The maintenance of breast compression thickness during the imaging procedure and calibration of the system to allow quantification of iodine in the breast represent new challenges to quality assurance. CESM provides a means of acquiring new information regarding tumor angiogenesis and may reveal some cancers that will not be detectable on digital mammography. It may also better demonstrate the extent of disease. The medical physicist must understand the dependence of image quality on physical factors. Implementation of a relevant QA program will be required if the promise of this new modality is to be delivered. © 2012 American Association of Physicists in Medicine.

  2. Towards in vivo TLD dosimetry in mammography.

    PubMed

    Warren-Forward, H M; Duggan, L

    2004-05-01

    While phantoms are used for quality control assessment of the mammography unit, in vivo dose measurements are necessary to account for the variation in size and composition of the female breast. The use of thermoluminescent dosimeters (TLDs) in mammography has been limited due to TLD visibility. The aim of this current investigation was to access the suitability of a paper-thin LiF:Mg,Cu,P TLD (GR-200F) for in vivo dosimetric mammography measurements. The visibility of GR-200F has been directly compared with LiF:Mg,Cu,P TLDs (GR-200A) using a number of commercially available phantoms. The phantoms of thickness 2-5 cm were imaged over the range of tube potentials (24-28 kVp) used clinically. Both types of TLD were placed on the surface of the phantoms allowing assessment of visibility, entrance surface dose (ESD) and field homogeneity. In vivo assessment of ESD and visibility was also carried out on a volunteer undergoing a routine mammography examination. The positions of the GR-200F TLDs were not identified either on the image of the Leeds TOR(MAM) phantom or the patient mammograms. The average ESD for the Leeds phantom was 8.8 mGy, while the patient ESD was 13 mGy. It is now possible to perform in vivo measurements with the potential of increasing the accuracy of the doses measured for women that do not conform to a standard breast thickness or density.

  3. Inconsistent self-reported mammography history: Findings from the National Population Health Survey longitudinal cohort

    PubMed Central

    Bancej, Christina M; Maxwell, Colleen J; Snider, Judy

    2004-01-01

    Background Self-reported information has commonly been used to monitor mammography utilization across populations and time periods. However, longitudinal investigations regarding the prevalence and determinants of inconsistent responses over time and the impact of such responses on population screening estimates are lacking. Methods Based on longitudinal panel data for a representative cohort of Canadian women aged 40+ years (n = 3,537) assessed in the 1994–95 (baseline) and 1996–97 (follow-up) National Population Health Survey (NPHS), we examined the prevalence of inconsistent self-reports of mammography utilization. Logistic regression models were used to estimate the associations between women's baseline sociodemographic and health characteristics and 2 types of inconsistent responses: (i) baseline reports of ever use which were subsequently contradicted by follow-up reports of never use; and (ii) baseline reports of never use which were contradicted by follow-up reports of use prior to 1994–95. Results Among women who reported having a mammogram at baseline, 5.9% (95% confidence interval (CI): 4.6–7.3%) reported at follow-up that they had never had one. Multivariate logistic regression analyses showed that women with such inconsistent responses were more often outside target age groups, from low income households and less likely to report hormone replacement therapy and Pap smear use. Among women reporting never use at baseline and ever use at follow-up, 17.4% (95%CI: 11.7–23.1%) reported their most recent mammogram as occurring prior to 1994–95 (baseline) and such responses were more common among women aged 70+ years and those in poorer health. Conclusions Women with inconsistent responses of type (i), i.e., ever users at baseline but never users at follow-up, appeared to exhibit characteristics typical of never users of mammography screening. Although limited by sample size, our preliminary analyses suggest that type (ii) responses are more likely

  4. CADx Mammography

    NASA Astrophysics Data System (ADS)

    Costaridou, Lena

    Although a wide variety of Computer-Aided Diagnosis (CADx) schemes have been proposed across breast imaging modalities, and especially in mammography, research is still ongoing to meet the high performance CADx requirements. In this chapter, methodological contributions to CADx in mammography and adjunct breast imaging modalities are reviewed, as they play a major role in early detection, diagnosis and clinical management of breast cancer. At first, basic terms and definitions are provided. Then, emphasis is given to lesion content derivation, both anatomical and functional, considering only quantitative image features of micro-calcification clusters and masses across modalities. Additionally, two CADx application examples are provided. The first example investigates the effect of segmentation accuracy on micro-calcification cluster morphology derivation in X-ray mammography. The second one demonstrates the efficiency of texture analysis in quantification of enhancement kinetics, related to vascular heterogeneity, for mass classification in dynamic contrast-enhanced magnetic resonance imaging.

  5. Does Distance Matter? Distance to Mammography Facilities and Stage at Diagnosis of Breast Cancer in Kentucky

    ERIC Educational Resources Information Center

    Huang, Bin; Dignan, Mark; Han, Daikwon; Johnson, Owen

    2009-01-01

    Background: National and regional data indicate that breast cancer early detection is low in Kentucky, especially rural regions, perhaps because access to mammography services can be problematic. Objective: This study examined the distance between residences of women diagnosed with breast cancer and the nearest mammography facility, as a risk…

  6. Mammography screening in six diverse communities in Chicago--a population study.

    PubMed

    Whitman, Steve; Shah, Ami M; Silva, Abigail; Ansell, David

    2007-01-01

    Despite the fact that recent studies suggest a narrowing in access to mammography, Black women are much more likely to die from breast cancer than White women. Data at the community level regarding mammography screening can help explain health disparities and inform plans for improved screening efforts. In 2002-2003, a comprehensive household health survey in English or Spanish was conducted in six community areas with 1700 households. The module on mammography was based on a state-based nationwide health survey and included questions on frequency of mammography, repeat screenings, and several demographic variables. The proportion of women >or=40 years (n=482) who received a mammogram in the past 2 years ranged from 74% to 90% across the six communities. The community with the highest screening proportion was predominantly Mexican and included recent immigrants. The screening proportion in the poorest community area, which was all Black, was 77%. Women with health insurance, higher income, and more education were more likely to receive a mammogram. Proportions for women >or=50 years (n=286) were slightly higher but similar. Repeat screening, which is recommended, occurred at lower levels. Access to and utilization of mammography have grown in recent years so that even these vulnerable communities had screening proportions at or even higher than the national average and the Healthy People Year 2010 objective. Nonetheless, repeat screening sequences were lower and may require attention if mammography screening efforts are to have a greater impact on female breast cancer mortality.

  7. External validation of Medicare claims codes for digital mammography and computer-aided detection.

    PubMed

    Fenton, Joshua J; Zhu, Weiwei; Balch, Steven; Smith-Bindman, Rebecca; Lindfors, Karen K; Hubbard, Rebecca A

    2012-08-01

    While Medicare claims are a potential resource for clinical mammography research or quality monitoring, the validity of key data elements remains uncertain. Claims codes for digital mammography and computer-aided detection (CAD), for example, have not been validated against a credible external reference standard. We matched Medicare mammography claims for women who received bilateral mammograms from 2003 to 2006 to corresponding mammography data from the Breast Cancer Surveillance Consortium (BCSC) registries in four U.S. states (N = 253,727 mammograms received by 120,709 women). We assessed the accuracy of the claims-based classifications of bilateral mammograms as either digital versus film and CAD versus non-CAD relative to a reference standard derived from BCSC data. Claims data correctly classified the large majority of film and digital mammograms (97.2% and 97.3%, respectively), yielding excellent agreement beyond chance (κ = 0.90). Claims data correctly classified the large majority of CAD mammograms (96.6%) but a lower percentage of non-CAD mammograms (86.7%). Agreement beyond chance remained high for CAD classification (κ = 0.83). From 2003 to 2006, the predictive values of claims-based digital and CAD classifications increased as the sample prevalences of each technology increased. Medicare claims data can accurately distinguish film and digital bilateral mammograms and mammograms conducted with and without CAD. The validity of Medicare claims data regarding film versus digital mammography and CAD suggests that these data elements can be useful in research and quality improvement. ©2012 AACR.

  8. Can tailored interventions increase mammography use among HMO women?

    PubMed

    Lipkus, I M; Rimer, B K; Halabi, S; Strigo, T S

    2000-01-01

    Telephone counseling and tailored print communications have emerged as promising methods for promoting mammography screening. However, there has been little research testing, within the same randomized field trial, of the efficacy of these two methods compared to a high-quality usual care system for enhancing screening. This study addressed the question: Compared to usual care, is tailored telephone counseling more effective than tailored print materials for promoting mammography screening? Three-year randomized field trial. One thousand ninety-nine women aged 50 and older recruited from a health maintenance organization in North Carolina. Women were randomized to 1 of 3 groups: (1) usual care, (2) tailored print communications, and (3) tailored telephone counseling. Adherence to mammography screening based on self-reports obtained during 1995, 1996, and 1997. Compared to usual care alone, telephone counseling promoted a significantly higher proportion of women having mammograms on schedule (71% vs 61%) than did tailored print (67% vs 61%) but only after the first year of intervention (during 1996). Furthermore, compared to usual care, telephone counseling was more effective than tailored print materials at promoting being on schedule with screening during 1996 and 1997 among women who were off-schedule during the previous year. The effects of the intervention were most pronounced after the first intervention. Compared to usual care, telephone counseling seemed particularly effective at promoting change among nonadherent women, the group for whom the intervention was developed. These results suggest that telephone counseling, rather than tailored print, might be the preferred first-line intervention for getting nonadherent women on schedule for mammography screening. Many questions would have to be answered about why the tailored print intervention was not more powerful. Nevertheless, it is clear that additional interventions will be needed to maintain women

  9. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    PubMed

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  10. The mammography screening employee inreach program.

    PubMed

    Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria

    2007-02-01

    To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.

  11. Analyser-based mammography using single-image reconstruction.

    PubMed

    Briedis, Dahliyani; Siu, Karen K W; Paganin, David M; Pavlov, Konstantin M; Lewis, Rob A

    2005-08-07

    We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.

  12. Breast compression in mammography: how much is enough?

    PubMed

    Poulos, Ann; McLean, Donald; Rickard, Mary; Heard, Robert

    2003-06-01

    The amount of breast compression that is applied during mammography potentially influences image quality and the discomfort experienced. The aim of this study was to determine the relationship between applied compression force, breast thickness, reported discomfort and image quality. Participants were women attending routine breast screening by mammography at BreastScreen New South Wales Central and Eastern Sydney. During the mammographic procedure, an 'extra' craniocaudal (CC) film was taken at a reduced level of compression ranging from 10 to 30 Newtons. Breast thickness measurements were recorded for both the normal and the extra CC film. Details of discomfort experienced, cup size, menstrual status, existing breast pain and breast problems were also recorded. Radiologists were asked to compare the image quality of the normal and manipulated film. The results indicated that 24% of women did not experience a difference in thickness when the compression was reduced. This is an important new finding because the aim of breast compression is to reduce breast thickness. If breast thickness is not reduced when compression force is applied then discomfort is increased with no benefit in image quality. This has implications for mammographic practice when determining how much breast compression is sufficient. Radiologists found a decrease in contrast resolution within the fatty area of the breast between the normal and the extra CC film, confirming a decrease in image quality due to insufficient applied compression force.

  13. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study.

    PubMed

    Skaane, Per; Young, Kari; Skjennald, Arnulf

    2003-12-01

    To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.

  14. Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography.

    PubMed

    Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I

    2014-10-01

    Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.

  15. Cost effectiveness of mammography screening for Chinese women.

    PubMed

    Wong, Irene O L; Kuntz, Karen M; Cowling, Benjamin J; Lam, Cindy L K; Leung, Gabriel M

    2007-08-15

    Although the cost effectiveness of screening mammography in most western developed populations has been accepted, it may not apply to Chinese women, who have a much lower breast cancer incidence. The authors estimated the cost effectiveness of biennial mammography in Hong Kong Chinese women to inform evidence-based screening policies. For the current study, a state-transition Markov model was developed to simulate mammography screening, breast cancer diagnosis, and treatment in a hypothetical cohort of Chinese women. The benefit of mammography was modeled by assuming a stage shift, in which cancers in screened women were more likely to be diagnosed at an earlier disease stage. The authors compared costs, quality-adjusted life years (QALYs) saved, and life years saved (LYS) for 5 screening strategies. Biennial screening resulted in a gain in life expectancy ranging from 4.3 days to 9.4 days compared with no screening at an incremental cost of from US $1,166 to US $2,425 per woman. The least costly, nondominated screening option was screening from ages 40 years to 69 years, with an incremental cost-effectiveness ratio (ICER) of US $61,600 per QALY saved or US $64,400 per LYS compared with no screening. In probabilistic sensitivity analyses, the probability of the ICER being below a threshold of US $50,000 per QALY (LYS) was 15.3% (14.6%). The current results suggested that mammography for Hong Kong Chinese women currently may not be cost effective based on the arbitrary threshold of US $50,000 per QALY. However, clinicians must remain vigilant and periodically should revisit the question of population screening: Disease rates in China have been increasing because of westernization and socioeconomic development.

  16. Does performance of breast self-exams increase the probability of using mammography: evidence from Malaysia.

    PubMed

    Dunn, Richard A; Tan, Andrew; Samad, Ismail

    2010-01-01

    Breast self-examination (BSE) was evaluated to see if it is a significant predictor of mammography. The decisions of females above age 40 in Malaysia to test for breast cancer using BSE and mammography are jointly modeled using a bivariate probit so that unobserved attributes affecting mammography usage are also allowed to affect BSE. Data come from the Malaysia Non-Communicable Disease Surveillance-1, which was collected between September 2005 and February 2006. Having ever performed BSE is positively associated with having ever undergone mammography among Malay (adjusted OR=7.343, CI=2.686, 20.079) and Chinese (adjusted OR=3.466, CI=1.330, 9.031) females after adjusting for household income, education, marital status and residential location. Neither relationship is affected by jointly modelling the decision problem. Although the association is also positive for Indian females when mammography is modelled separately (adjusted OR=5.959, CI=1.546 - 22.970), the relationship is reversed when both decisions are modelled separately. De-emphasizing BSE in Malaysia may reduce mammography screening among a large proportion of the population. Previous work on the issue in developed countries may not apply to nations with limited resources.

  17. Signal uniformity of mammography systems and its impact on test results from contrast detail phantoms

    NASA Astrophysics Data System (ADS)

    Kaar, M.; Semturs, F.; Hummel, J.; Hoffmann, R.; Figl, M.

    2015-03-01

    Technical quality assurance (TQA) procedures for mammography systems usually include tests with a contrast-detail phantom. These phantoms contain multiple objects of varying dimensions arranged on a flat body. Exposures of the phantom are then evaluated by an observer, either human or software. One well-known issue of this method is that dose distribution is not uniform across the image area of any mammography system, mainly due to the heel effect. The purpose of this work is to investigate to what extent image quality differs across the detector plane. We analyze a total of 320 homogeneous mammography exposures from 32 radiology institutes. Systems of different models and manufacturers, both computed radiography (CR) and direct radiography (DR) are included. All images were taken from field installations operated within the nationwide Austrian mammography screening program, which includes mandatory continuous TQA. We calculate signal-to-noise ratios (SNR) for 15 regions of interest arranged to cover the area of the phantom. We define the 'signal range' of an image and compare this value categorized by technologies. We found the deviations of SNR greater in anterior-posterior than in lateral direction. SNR ranges are significantly higher for CR systems than for DR systems.

  18. [Controversial attitude to mammography screening in asymptomatic women between 40 and 50 years of age].

    PubMed

    Frischbier, H J

    1994-01-01

    The results of screening studies conducted in the United States and in Europe in females between the ages of 40 and 50 are analysed. It is shown, that the results of this study on mortality reduction are less favourable, the poorer the technique of mammography (foregoing of general two-view mammography) and the longer the time interval between two mammography screenings. Arguments are presented, that are brought forward when declining to perform general mammography screening in this age group. The author's own results, obtained in the Hamburg mammography screening study, which included from 1971 to 1986 also premenopausal women, show, that the survival rates of patients below 50 years of age with mammographically detected carcinomas of the breast do not differ from those in patients older than 50 years, according to a relevant age group classification. The advances in the technique of mammography in recent years are analysed on the basis of the author's own patient material. It is evident, that the positive predictive value has been doubled, especially in the age group between 40 and 50. An analysis of the distribution of diagnosed noninvasive carcinomas compared with the invasive carcinomas reveals, that particularly this age group has the highest percentage of identification of prognostically favourable carcinoma stages. Further analyses show, why the randomised European mammography studies could not yield a significant mortality rate improvement. A prerequisite for the inclusion of mammography screening in the legally prescribed early detection of carcinoma examinations, however, are the quality controls, whose realisation, in our health system, will have to be confirmed by the German mammography study.

  19. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco

    2008-08-01

    The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

  20. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez

    2008-08-11

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less

  1. Evaluation of low-energy contrast-enhanced spectral mammography images by comparing them to full-field digital mammography using EUREF image quality criteria.

    PubMed

    Lalji, U C; Jeukens, C R L P N; Houben, I; Nelemans, P J; van Engen, R E; van Wylick, E; Beets-Tan, R G H; Wildberger, J E; Paulis, L E; Lobbes, M B I

    2015-10-01

    Contrast-enhanced spectral mammography (CESM) examination results in a low-energy (LE) and contrast-enhanced image. The LE appears similar to a full-field digital mammogram (FFDM). Our aim was to evaluate LE CESM image quality by comparing it to FFDM using criteria defined by the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services (EUREF). A total of 147 cases with both FFDM and LE images were independently scored by two experienced radiologists using these (20) EUREF criteria. Contrast detail measurements were performed using a dedicated phantom. Differences in image quality scores, average glandular dose, and contrast detail measurements between LE and FFDM were tested for statistical significance. No significant differences in image quality scores were observed between LE and FFDM images for 17 out of 20 criteria. LE scored significantly lower on one criterion regarding the sharpness of the pectoral muscle (p < 0.001), and significantly better on two criteria on the visualization of micro-calcifications (p = 0.02 and p = 0.034). Dose and contrast detail measurements did not reveal any physical explanation for these observed differences. Low-energy CESM images are non-inferior to FFDM images. From this perspective FFDM can be omitted in patients with an indication for CESM. • Low-energy CESM images are non-inferior to FFDM images. • Micro-calcifications are significantly more visible on LE CESM than on FFDM. • There is no physical explanation for this improved visibility of micro-calcifications. • There is no need for an extra FFDM when CESM is indicated.

  2. Developing a Mass Media Campaign to Promote Mammography Awareness in African American Women in the Nation's Capital.

    PubMed

    Wallington, Sherrie Flynt; Oppong, Bridget; Iddirisu, Marquita; Adams-Campbell, Lucile L

    2017-12-26

    This study developed and examined the reach and impact of a culturally appropriate mass media campaign pilot, designed to increase awareness about the importance of mammography screening and the available community mammography services for low-income African American women ages 40 and above. We conducted formative research using focus groups to inform campaign development, resulting in five emergent themes-good breast health, holistic views of healthiness, cancer fatalism, fear of mammogram machines, and mammogram affordability. The campaign targeted specific low-income African American communities in the District of Columbia via print ads in Metro stations and on buses, print ads in the Washington Informer, and online ads on a local TV network website. Data were collected before, during, and after campaign implementation to assess reach and impact. Reach was measured by number of impressions (number of people exposed to the campaign), while impact was assessed via online ad click-through rates, website use and referrals, and mammography center calls. The campaign was successful in reaching the target audience, with a total combined reach from all media of 9,479,386 impressions. In addition, the mammography center received significant increases in new website visitors (1482 during the campaign, compared to 24 during the preceding period) as well as 97 calls to the dedicated phone line. Further research involving a more long-term investment in terms of funding and campaign run time, coupled with a more robust evaluation, is needed to assess if culturally appropriate mass media campaigns can generate increased mammography screening rates and decrease breast-cancer-related mortality.

  3. Comparative Effectiveness of Digital Versus Film-Screen Mammography in Community Practice in the United States

    PubMed Central

    Kerlikowske, Karla; Hubbard, Rebecca A.; Miglioretti, Diana L.; Geller, Berta M.; Yankaskas, Bonnie C.; Lehman, Constance D.; Taplin, Stephen H.; Sickles, Edward A.

    2013-01-01

    offered mammography screening, they may choose to undergo digital mammography to optimize cancer detection. Primary Funding Source National Cancer Institute. PMID:22007043

  4. One more hurdle to increasing mammography screening: pubescent, adolescent, and prior mammography screening experiences.

    PubMed

    Thomas, Eileen; Usher, LaToya

    2009-01-01

    Approximately $8.1 billion dollars is spent each year in the United States alone on the treatment of breast cancer. Survival rates are dependent on access to, and utilization of, early detection services. The primary reason for disparity in breast cancer mortality is the delay in time to diagnosis, resulting in poor prognosis. Despite ongoing research to understand barriers to mammography screening, recent studies report a decrease in mammography screening among all racial groups. A qualitative approach was used to elicit information from 36 White non- Hispanic, African-American, Hispanic, and Native American women without a history of breast cancer. Women were invited to share written or audiotape-recorded narratives about experiences pertaining to their breasts and their mammography screening experiences. Major categories identified were: teasing, family norms and values, media/societal influence, body image, and mammography screening experiences. The resulting effects of these experiences left these women with feelings of shame and "conflict" regarding their breasts. The major theme identified was breast conflict. Findings suggest that breast conflict may persist throughout the lifespan and can have a negative influence on a woman's decision to participate in mammography screening. The authors hypothesize that experiences that occur during adolescence pertaining to young girls' breasts can influence a women's body image, which in turn can later in life affect health-seeking behaviors related to mammography screening. These findings have implications for public health practice in planning for breast cancer screening, education, and interventions for women from diverse racial/ethnics groups.

  5. Effects of a risk-based online mammography intervention on accuracy of perceived risk and mammography intentions.

    PubMed

    Seitz, Holli H; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M; Armstrong, Katrina; Cappella, Joseph N

    2016-10-01

    This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. 2918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (<1.5%; ≥1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) x 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk ≤1.5%. For women with a risk≤1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Effects of a Risk-based Online Mammography Intervention on Accuracy of Perceived Risk and Mammography Intentions

    PubMed Central

    Seitz, Holli H.; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M.; Armstrong, Katrina; Cappella, Joseph N.

    2016-01-01

    Objective This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. Methods 2,918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (< 1.5%; ≥ 1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) × 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Results Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk <1.5%. For women with a risk < 1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. Conclusion A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Practice Implications Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. PMID:27178707

  7. Full-field digital mammography image data storage reduction using a crop tool.

    PubMed

    Kang, Bong Joo; Kim, Sung Hun; An, Yeong Yi; Choi, Byung Gil

    2015-05-01

    The storage requirements for full-field digital mammography (FFDM) in a picture archiving and communication system are significant, so methods to reduce the data set size are needed. A FFDM crop tool for this purpose was designed, implemented, and tested. A total of 1,651 screening mammography cases with bilateral FFDMs were included in this study. The images were cropped using a DICOM editor while maintaining image quality. The cases were evaluated according to the breast volume (1/4, 2/4, 3/4, and 4/4) in the craniocaudal view. The image sizes between the cropped image group and the uncropped image group were compared. The overall image quality and reader's preference were independently evaluated by the consensus of two radiologists. Digital storage requirements for sets of four uncropped to cropped FFDM images were reduced by 3.8 to 82.9 %. The mean reduction rates according to the 1/4-4/4 breast volumes were 74.7, 61.1, 38, and 24 %, indicating that the lower the breast volume, the smaller the size of the cropped data set. The total image data set size was reduced from 87 to 36.7 GB, or a 57.7 % reduction. The overall image quality and the reader's preference for the cropped images were higher than those of the uncropped images. FFDM mammography data storage requirements can be significantly reduced using a crop tool.

  8. Digital mammography--DQE versus optimized image quality in clinical environment: an on site study

    NASA Astrophysics Data System (ADS)

    Oberhofer, Nadia; Fracchetti, Alessandro; Springeth, Margareth; Moroder, Ehrenfried

    2010-04-01

    The intrinsic quality of the detection system of 7 different digital mammography units (5 direct radiography DR; 2 computed radiography CR), expressed by DQE, has been compared with their image quality/dose performances in clinical use. DQE measurements followed IEC 62220-1-2 using a tungsten test object for MTF determination. For image quality assessment two different methods have been applied: 1) measurement of contrast to noise ratio (CNR) according to the European guidelines and 2) contrast-detail (CD) evaluation. The latter was carried out with the phantom CDMAM ver. 3.4 and the commercial software CDMAM Analyser ver. 1.1 (both Artinis) for automated image analysis. The overall image quality index IQFinv proposed by the software has been validated. Correspondence between the two methods has been shown figuring out a linear correlation between CNR and IQFinv. All systems were optimized with respect to image quality and average glandular dose (AGD) within the constraints of automatic exposure control (AEC). For each equipment, a good image quality level was defined by means of CD analysis, and the corresponding CNR value considered as target value. The goal was to achieve for different PMMA-phantom thicknesses constant image quality, that means the CNR target value, at minimum dose. All DR systems exhibited higher DQE and significantly better image quality compared to CR systems. Generally switching, where available, to a target/filter combination with an x-ray spectrum of higher mean energy permitted dose savings at equal image quality. However, several systems did not allow to modify the AEC in order to apply optimal radiographic technique in clinical use. The best ratio image quality/dose was achieved by a unit with a-Se detector and W anode only recently available on the market.

  9. Does Gender Discrimination Impact Regular Mammography Screening? Findings from the Race Differences in Screening Mammography Study

    PubMed Central

    DAILEY, AMY B.; KASL, STANISLAV V.; JONES, BETH A.

    2011-01-01

    Objective To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. Methods African American and white women (1451) aged 40–79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Results Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of ≥$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Conclusions Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women. PMID:18321171

  10. Does gender discrimination impact regular mammography screening? Findings from the race differences in screening mammography study.

    PubMed

    Dailey, Amy B; Kasl, Stanislav V; Jones, Beth A

    2008-03-01

    ABSTRACT Objective: To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. African American and white women (1451) aged 40-79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of > or =$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women.

  11. Ultrasound as an Adjunct to Mammography for Breast Cancer Screening: A Health Technology Assessment

    PubMed Central

    Nikitovic-Jokic, Milica; Tu, Hong Anh; Palimaka, Stefan; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    . Conclusions We found no evidence that evaluated the comparative effectiveness or diagnostic accuracy of screening breast ultrasound as an adjunct to mammography among average-risk women aged 50 years and over. In women at high risk of developing breast cancer, there is low-quality evidence that screening with mammography and adjunct ultrasound detects additional cases of disease, with improved sensitivity compared to mammography alone. Screening with adjunct ultrasound also increases the number of false-positive findings and subsequent biopsy recommendations. It is unclear if the use of screening breast ultrasound as an adjunct to mammography will reduce breast cancer–related mortality among high-risk women. The annual cost burden of using adjunct ultrasound to screen high-risk women who cannot receive MRI in Ontario would be small. PMID:27468326

  12. Family/Friend Recommendations and Mammography Intentions: The Roles of Perceived Mammography Norms and Support

    ERIC Educational Resources Information Center

    Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.

    2015-01-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography…

  13. Digital mammography: more microcalcifications, more columnar cell lesions without atypia.

    PubMed

    Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J

    2011-09-01

    The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2

  14. Perspectives of Mobile Versus Fixed Mammography in Santa Clara County, California: A Focus Group Study.

    PubMed

    Chen, Yi-Ren; Chang-Halpenny, Christine; Kumarasamy, Narmadan A; Venegas, Angela; Braddock Iii, Clarence H

    2016-02-12

    Our aim was to examine underserved women's perceptions on mobile versus fixed mammography in Santa Clara, California through a focus group study.  Research has shown that medically underserved women have higher breast cancer mortality rates correlated with under-screening and a disproportional rate of late-stage diagnosis. The Community Health Partnership in Santa Clara County, California runs the Community Mammography Access Project (CMAP) that targets nearly 20,000 medically underserved women over the age of 40 in the county through the collaborative effort of an existing safety net of healthcare providers. However, little data exists on the advantages or disadvantages of mobile mammography units from the patient perspective.   We assessed underserved women's perspectives on mammography services in Santa Clara County through two focus groups from women screened at mobile or fixed site programs. Patients were recruited from both CMAP clinics and a county hospital, and focus group data were analyzed using content analysis.  We found that women from both the mobile and fixed sites shared similar motivating factors for getting a mammogram. Both groups recognized that screening was uncomfortable but necessary for good health and had positive feedback about their personal physicians. However, mobile participants, in particular, appreciated the atmosphere of mobile screening, reported shorter wait times, and remarked on the good communication from the clinic staff and empathetic treatment they received. However, mobile participants also expressed concern about the quality of films at mobile sites due to delayed initial reading of the films.   Mobile mammography offers a unique opportunity for women of underserved populations to access high satisfaction screenings, and it encourages a model similar to CMAP in other underserved areas. However, emphasis should be placed on providing a warm and welcoming environment for patients and ensuring the quality of

  15. A prototype of mammography CADx scheme integrated to imaging quality evaluation techniques

    NASA Astrophysics Data System (ADS)

    Schiabel, Homero; Matheus, Bruno R. N.; Angelo, Michele F.; Patrocínio, Ana Claudia; Ventura, Liliane

    2011-03-01

    As all women over the age of 40 are recommended to perform mammographic exams every two years, the demands on radiologists to evaluate mammographic images in short periods of time has increased considerably. As a tool to improve quality and accelerate analysis CADe/Dx (computer-aided detection/diagnosis) schemes have been investigated, but very few complete CADe/Dx schemes have been developed and most are restricted to detection and not diagnosis. The existent ones usually are associated to specific mammographic equipment (usually DR), which makes them very expensive. So this paper describes a prototype of a complete mammography CADx scheme developed by our research group integrated to an imaging quality evaluation process. The basic structure consists of pre-processing modules based on image acquisition and digitization procedures (FFDM, CR or film + scanner), a segmentation tool to detect clustered microcalcifications and suspect masses and a classification scheme, which evaluates as the presence of microcalcifications clusters as well as possible malignant masses based on their contour. The aim is to provide enough information not only on the detected structures but also a pre-report with a BI-RADS classification. At this time the system is still lacking an interface integrating all the modules. Despite this, it is functional as a prototype for clinical practice testing, with results comparable to others reported in literature.

  16. Mammography decision making: Trends and predictors of provider communication in the Health Information National Trends Survey, 2011 to 2014.

    PubMed

    Spring, Laura M; Marshall, Megan R; Warner, Erica T

    2017-02-01

    In 2009, the US Preventive Services Task Force recommended that the decision to initiate screening mammography before age 50 years should be individualized. Herein, the authors examined whether health care providers are communicating regarding mammography decision making with women and whether communication is associated with screening behavior. Data were drawn from the 2011 to 2014 Health Information National Trends Survey (HINTS). A total of 5915 female respondents aged ≥ 40 years who responded to the following question were included: "Has a doctor or other health professional ever told you that you could choose whether or not to have a mammogram?" We used logistic regression to generate odds ratios (ORs) and 95% confidence intervals (95% CIs) for predictors of provider communication and assessed whether provider communication was associated with mammography in the previous 2 years overall and stratified by age. Fewer than 50% of the women reported provider communication regarding mammogram choice. Women who reported provider communication were not found to be more likely to report no mammogram within the past 2 years (OR, 1.07; 95% CI, 0.87-1.31) compared with those who did not. When stratified by 10-year age group, provider communication was associated with a higher likelihood of no mammogram only among women age ≥70 years (OR, 1.64; 95% CI, 1.15-2.34), and was associated with a lower likelihood of no mammogram only among women aged 40 to 49 years (OR, 0.63; 95% CI, 0.43-0.92). Between 2011 and 2014, less than one-half of women received communication regarding mammogram choice despite recommendations from the US Preventive Services Task Force. Provider communication regarding mammogram choice can influence screening behavior, particularly for younger and older women. Cancer 2017;123:401-409. © 2016 American Cancer Society. © 2016 American Cancer Society.

  17. Computational assessment of mammography accreditation phantom images and correlation with human observer analysis

    NASA Astrophysics Data System (ADS)

    Barufaldi, Bruno; Lau, Kristen C.; Schiabel, Homero; Maidment, D. A.

    2015-03-01

    Routine performance of basic test procedures and dose measurements are essential for assuring high quality of mammograms. International guidelines recommend that breast care providers ascertain that mammography systems produce a constant high quality image, using as low a radiation dose as is reasonably achievable. The main purpose of this research is to develop a framework to monitor radiation dose and image quality in a mixed breast screening and diagnostic imaging environment using an automated tracking system. This study presents a module of this framework, consisting of a computerized system to measure the image quality of the American College of Radiology mammography accreditation phantom. The methods developed combine correlation approaches, matched filters, and data mining techniques. These methods have been used to analyze radiological images of the accreditation phantom. The classification of structures of interest is based upon reports produced by four trained readers. As previously reported, human observers demonstrate great variation in their analysis due to the subjectivity of human visual inspection. The software tool was trained with three sets of 60 phantom images in order to generate decision trees using the software WEKA (Waikato Environment for Knowledge Analysis). When tested with 240 images during the classification step, the tool correctly classified 88%, 99%, and 98%, of fibers, speck groups and masses, respectively. The variation between the computer classification and human reading was comparable to the variation between human readers. This computerized system not only automates the quality control procedure in mammography, but also decreases the subjectivity in the expert evaluation of the phantom images.

  18. The clinical effectiveness and cost-effectiveness of different surveillance mammography regimens after the treatment for primary breast cancer: systematic reviews registry database analyses and economic evaluation.

    PubMed

    Robertson, C; Arcot Ragupathy, S K; Boachie, C; Dixon, J M; Fraser, C; Hernández, R; Heys, S; Jack, W; Kerr, G R; Lawrence, G; MacLennan, G; Maxwell, A; McGregor, J; Mowatt, G; Pinder, S; Ternent, L; Thomas, R E; Vale, L; Wilson, R; Zhu, S; Gilbert, F J

    2011-09-01

    mammography directly. The results of the economic model should be considered exploratory and interpreted with caution given the paucity of data available to inform the economic model. Surveillance is likely to improve survival and patients should gain maximum benefit through optimal use of resources, with those women with a greater likelihood of developing IBTR or MCBC being offered more comprehensive and more frequent surveillance. Further evidence is required to make a robust and informed judgement on the effectiveness of surveillance mammography and follow-up. The utility of national data sets could be improved and there is a need for high-quality, direct head-to-head studies comparing the diagnostic accuracy of tests used in the surveillance population. The National Institute for Health Research Health Technology Assessment programme. © Queen’s Printer and Controller of HMSO 2011.

  19. The professional quality criteria of Italian breast screening radiologists: results from a national survey comparing the programmes started in 2000-2012 versus the ones started in 1990-1999.

    PubMed

    Morrone, Doralba; Giordano, Livia; Artuso, Franca; Bernardi, Daniela; Fedato, Chiara; Frigerio, Alfonso; Giorgi, Daniela; Naldoni, Carlo; Saguatti, Gianni; Severi, Daniela; Taffurelli, Mario; Terribile, Daniela; Ventura, Leonardo; Bucchi, Lauro

    2017-01-01

    In Italy, due to increasing healthcare budget and staff shortages, the recently created regional mammography screening programmes were established under worse radiology practice quality criteria than the previously created programmes. Using available data from a national questionnaire survey conducted at the end of 2013 and involving 222 responder radiologists, we compared the main professional quality standards of radiologists working in the screening programmes established during the period 2000-2012 with those working in the screening programmes created from 1990 to 1999. The former reported more years of clinical experience in breast imaging and a greater clinical mammogram reading volume than the latter. Conversely, they dedicated less working time to breast imaging, were less likely to participate in the diagnostic assessment of screen-detected lesions, to work in large-staffed screening centres, and to have a screening and a total mammogram reading volume (SMRV and TMRV) ≥ 5000 per year. The level of most professional quality criteria of Italian mammography screening radiologists has decreased over time. As SMRV and TMRV are important predictors of diagnostic accuracy, we can expect a lower interpretation performance of radiologists working in the recently created screening programmes.

  20. Impact on dose and image quality of a software-based scatter correction in mammography.

    PubMed

    Monserrat, Teresa; Prieto, Elena; Barbés, Benigno; Pina, Luis; Elizalde, Arlette; Fernández, Belén

    2018-06-01

    Background In 2014, Siemens developed a new software-based scatter correction (Progressive Reconstruction Intelligently Minimizing Exposure [PRIME]), enabling grid-less digital mammography. Purpose To compare doses and image quality between PRIME (grid-less) and standard (with anti-scatter grid) modes. Material and Methods Contrast-to-noise ratio (CNR) was measured for various polymethylmethacrylate (PMMA) thicknesses and dose values provided by the mammograph were recorded. CDMAM phantom images were acquired for various PMMA thicknesses and inverse Image Quality Figure (IQF inv ) was calculated. Values of incident entrance surface air kerma (ESAK) and average glandular dose (AGD) were obtained from the DICOM header for a total of 1088 pairs of clinical cases. Two experienced radiologists compared subjectively the image quality of a total of 149 pairs of clinical cases. Results CNR values were higher and doses were lower in PRIME mode for all thicknesses. IQF inv values in PRIME mode were lower for all thicknesses except for 40 mm of PMMA equivalent, in which IQF inv was slightly greater in PRIME mode. A mean reduction of 10% in ESAK and 12% in AGD in PRIME mode with respect to standard mode was obtained. The clinical image quality in PRIME and standard acquisitions resulted to be similar in most of the cases (84% for the first radiologist and 67% for the second one). Conclusion The use of PRIME software reduces, in average, the dose of radiation to the breast without affecting image quality. This reduction is greater for thinner and denser breasts.

  1. Dual-energy contrast-enhanced mammography.

    PubMed

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  2. Reduction in interval cancer rates following the introduction of two-view mammography in the UK breast screening programme

    PubMed Central

    Dibden, A; Offman, J; Parmar, D; Jenkins, J; Slater, J; Binysh, K; McSorley, J; Scorfield, S; Cumming, P; Liao, X-H; Ryan, M; Harker, D; Stevens, G; Rogers, N; Blanks, R; Sellars, S; Patnick, J; Duffy, S W

    2014-01-01

    Background: The introduction of two-view mammography at incident (subsequent) screens in the National Health Service Breast Screening Programme (NHSBSP) has led to an increased number of cancers detected at screen. However, the effect of two-view mammography on interval cancer rates has yet to be assessed. Methods: Routine screening and interval cancer data were collated from all screening programmes in the United Kingdom for women aged 50–64, screened between 1 April 2003 and 31 March 2005. Interval cancer rates were compared based on whether two-view mammography was in use at the last routine screen. Results: The reduction in interval cancers following screening using two-view mammography compared with one view was 0.68 per 1 000 women screened. Overall, this suggests the introduction of two-view mammography at incident screen was accompanied by a 15–20% reduction in interval cancer rates in the NHSBSP. Conclusion: The introduction of two-view mammography at incident screens is associated with a reduction in incidence of interval cancers. This is consistent with previous publications on a contemporaneous increase in screen-detected cancers. The results provide further evidence of the benefit of the use of two-view mammography at incident screens. PMID:24366303

  3. Professional and economic factors affecting access to mammography: a crisis today, or tomorrow? Results from a national survey.

    PubMed

    Farria, Dione M; Schmidt, Maria E; Monsees, Barbara S; Smith, Robert A; Hildebolt, Charles; Yoffie, Roberta; Monticciolo, Debra L; Feig, Stephen A; Bassett, Lawrence W

    2005-08-01

    Objective data and anecdotal reports have suggested that access to mammography may be declining because of facility closures and difficulty in recruiting and retaining radiologists and radiologic technologists. To gain insight into the practice patterns, use of emerging technologies, and concerns of breast imagers in current practice, the Society of Breast Imaging (SBI) conducted a national survey of breast imaging practices in the U.S. Between October 2003 and April 2004, the SBI conducted a survey of the SBI membership database, and received completed surveys from 575 breast imaging practices in the U.S. Responses to the survey regarding practice characteristics, the utilization of standard and emerging technologies, staffing, malpractice, finance, and morale were analyzed. Job vacancies for radiologists who read mammograms were reported in 163 practices (29%), 59 of which (10%) had 2 or more openings. A higher proportion of practices with job openings had long appointment waiting times for asymptomatic women when compared with fully staffed practices. Unfilled fellowship positions also were common, with 41 of 65 practices that offer fellowships reporting 47 openings. Among 554 responding practices, 55% reported that someone in their practice was sued because of a mammography related case within the past 5 years, and 50% of practices reported that the threat of lawsuits made radiologist staffing "moderately" or "a lot" more difficult. Of 521 responding practices, 35% reported financial losses in 2002. One in 5 respondents reported that they would prefer to spend less time in mammography, and fewer than 1 in 3 would recommend a breast imaging fellowship to a relative or friend. Emerging technologies, such as breast magnetic resonance imaging and screening ultrasound, currently are being performed in many practices. The survey results provide support for anecdotal reports that breast imaging practices face significant challenges and stresses, including shortages of

  4. Mammography usage with relevant factors among women with mental disabilities in Taiwan: a nationwide population-based study.

    PubMed

    Yen, Suh-May; Kung, Pei-Tseng; Tsai, Wen-Chen

    2015-02-01

    Women with mental illness are at increased risk of developing and dying from breast cancer and are thus in urgent need of breast cancer preventive care. This study examined the use of screening mammography by Taiwanese women with mental disabilities and analyzed factors affecting this use. 17,243 Taiwanese women with mental disabilities aged 50-69 years were retrospectively included as study subjects. Linked patient data were obtained from three national databases in Taiwan (the 2008 database of physically and mentally disabled persons, the Health Promotion Administration's 2007-2008 mammography screening data, and claims data from the National Health Insurance Research Database). Besides descriptive statistics and bivariate analysis, logistic regression analysis was also performed to examine factors affecting screening mammography use. The 2007-2008 mammography screening rate for Taiwanese women with mental disabilities was 8.79% (n=1515). Variables that significantly influenced screening use were income, education, presence of catastrophic illness/injury, severity of mental disability, and usage of other preventive care services. Screening was positively correlated with income and education. Those with catastrophic illness/injury were more likely to be screened (odds ratio [OR], 1.40; 95% CI=1.15-1.72). Severity of disability was negatively correlated with screening, with very severe, severe, and moderate disability being associated with 0.34-0.69 times the odds of screening as mild disability. In Taiwan, women with mental disabilities receive far less mammography screening than women in general. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Cost-effectiveness of strategies to enhance mammography use.

    PubMed

    Fishman, P; Taplin, S; Meyer, D; Barlow, W

    2000-01-01

    To estimate the cost-effectiveness of three strategies to increase breast cancer screening with mammography (reminder postcard, reminder telephone call, and motivational telephone call). Cost accounting for each strategy followed by cost-effectiveness analysis. DATA SOURCE FOR EFFECTIVENESS: Randomized trial of three strategies conducted at Group Health Cooperative of Puget Sound (GHC). Women 50 to 79 years of age who were enrolled in GHC's breast cancer screening program who did not schedule screening mammography within 2 months after it was recommended by letter. Health plan. Marginal cost-effectiveness of each additional woman screened. Because of its high cost (about $26 per call) and intermediate effectiveness, the motivational call was the least cost-effective strategy. If it was assumed that 50% of the women who scheduled mammography after receiving the reminder postcard would have scheduled mammography within 10 months even without it, marginal cost-effectiveness for the postcard among all women was $22 per woman screened versus $92 for the reminder call. Among women with no previous mammography, the marginal cost-effectiveness for the postcard was $70 versus $100 for the reminder call. Among women with no previous mammography, the choice between the reminder postcard and the reminder call was sensitive to assumptions about the percentage of women expected to receive mammography in the absence of other promotional strategies. A simple reminder postcard is the most cost-effective way to increase mammography. Choices about how to promote mammography will ultimately depend on plan values and willingness to invest in promotional strategies that increase participation at higher unit costs.

  6. Dual-energy in mammography: feasibility study

    NASA Astrophysics Data System (ADS)

    Jafroudi, Hamid; Lo, Shih-Chung B.; Li, Huai; Steller Artz, Dorothy E.; Freedman, Matthew T.; Mun, Seong K.

    1996-04-01

    The purpose of this work is to examine the feasibility of dual-energy techniques to enhance the detection of microcalcifications in digital mammography. The digital mammography system used in this study consists of two different mammography systems; one is the conventional mammography system with molybdenum target and Mo filtration and the other is the clinical version of a low dose x-ray system with tungsten target and aluminum filtration. The low dose system is optimized for screen-film mammography with a highly efficient scatter rejection device built by Fischer Imaging Systems for evaluation at NIH. The system was designed by the University of Southern California based on multiparameter optimization techniques. Prototypes of this system have been constructed and evaluated at the Center for Devices and Radiological Health. The digital radiography system is based on the Fuji 9000 computed radiography (CR) system which uses a storage phosphor imaging plate as the receptor. High resolution plates (HR-V) are used in this study. Dual-energy is one technique to reduce the structured noise associated with the complexity of the background of normal anatomy surrounding a lesion. This can be done by taking the advantage of the x-ray attenuation characteristics of two different structures such as soft tissue and bone in chest radiography. We have applied this technique to the detection of microcalcifications in mammography. The overall system performance based on this technique is evaluated. Results presented are based on the evaluation of phantom images.

  7. Intentions to Maintain Adherence to Mammography

    PubMed Central

    Bowling, J. Michael; Brewer, Noel T.; Lipkus, Isaac M.; Skinner, Celette Sugg; Strigo, Tara S.; Rimer, Barbara K.

    2008-01-01

    Abstract Objective Recent attention has focused on moving women from having initial mammograms to maintaining adherence to regular mammography schedules. We examined behavioral intentions to maintain mammography adherence, which include the likelihood of performing a behavior, and implementation intentions, specific action plans to obtain mammograms. Potential predictors were Theory of Planned Behavior constructs, previous barriers, previous mammography maintenance, and age. Methods Respondents were 2062 currently adherent women due for their next mammograms in 3–4 months according to American Cancer Society recommendations for annual screening. Statistical models were used to examine predictors of behavioral and two implementation intentions, including having thought about where women would get their next mammograms and having thought about making appointments. Results With the exception of pros, cons, and subjective norms, all variables predicted behavioral intentions (p ≤ 0.05). Stronger perceived control, previous mammography maintenance, and one barrier (vs. none) predicted being more likely to have thought about where to get their next mammograms. Previous maintenance and no barriers (vs. two) predicted being more likely to have thought about making appointments. Conclusions Our findings suggest that among women currently adherent to mammography, volitional factors, such as barriers, may be better predictors of implementation intentions than motivational factors, such as attitudes. Implementation variables may be useful in understanding how women move from intentions to action. Future research should examine how such factors relate to mammography maintenance behaviors and can be integrated into behavior change interventions. PMID:18657041

  8. Trimodel Mammography with Perfect Coregistration

    DTIC Science & Technology

    2017-02-01

    background, the major confounding factor in reading mammography; the imaging characteristics suggest that this contrast mechanism would be preferable...image with enhanced edges and reduced anatomical background, the major confounding factor in reading mammography; the imaging characteristics suggest...subjects, vertebrate animals , biohazards, and/or select agents Describe significant deviations, unexpected outcomes, or changes in approved protocols

  9. Elimination of Cost Sharing for Screening Mammography in Medicare Advantage Plans.

    PubMed

    Trivedi, Amal N; Leyva, Bryan; Lee, Yoojin; Panagiotou, Orestis A; Dahabreh, Issa J

    2018-01-18

    The Affordable Care Act (ACA) required most insurers and the Medicare program to eliminate cost sharing for screening mammography. We conducted a difference-in-differences study of biennial screening mammography among 15,085 women 65 to 74 years of age in 24 Medicare Advantage plans that eliminated cost sharing to provide full coverage for screening mammography, as compared with 52,035 women in 48 matched control plans that had and maintained full coverage. In plans that eliminated cost sharing, adjusted rates of biennial screening mammography increased from 59.9% (95% confidence interval [CI], 54.9 to 65.0) in the 2-year period before cost-sharing elimination to 65.4% (95% CI, 61.8 to 69.0) in the 2-year period thereafter. In control plans, the rates of biennial mammography were 73.1% (95% CI, 69.2 to 77.0) and 72.8% (95% CI, 69.7 to 76.0) during the same periods, yielding a difference in differences of 5.7 percentage points (95% CI, 3.0 to 8.4). The difference in differences was 9.8 percentage points (95% CI, 4.5 to 15.2) among women living in the areas with the highest quartile of educational attainment versus 4.3 percentage points (95% CI, 0.2 to 8.4) among women in the lowest quartile. As indicated by the difference-in-differences estimates, after the elimination of cost sharing, the rate of biennial mammography increased by 6.5 percentage points (95% CI, 3.7 to 9.4) for white women and 8.4 percentage points (95% CI, 2.5 to 14.4) for black women but was almost unchanged for Hispanic women (0.4 percentage points; 95% CI, -7.3 to 8.1). The elimination of cost sharing for screening mammography under the ACA was associated with an increase in rates of use of this service among older women for whom screening is recommended. The effect was attenuated among women living in areas with lower educational attainment and was negligible among Hispanic women. (Funded by the National Institute on Aging.).

  10. A comparison of the performance of digital mammography systems.

    PubMed

    Monnin, P; Gutierrez, D; Bulling, S; Guntern, D; Verdun, F R

    2007-03-01

    An objective analysis of image quality parameters was performed for six digital mammography systems. The presampled modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) for the systems were determined at different doses, for 28 kVp with a Mo/Mo or W/Al target/filter combination and 2 mm of additional aluminium filtration. The flat-panel units have higher MTF and DQE in the mid to high frequency range than standard CR systems. The highest DQE, over the whole dose range, is for the slit-scanning direct photon counting system. Dual-side read CR can overcome the inherent x-ray absorption and signal collection limitations of standard CR mammography, improving the low-frequency DQE by 40%, to the same level as full-field systems, but it does not improve the poor spatial resolution of phosphor.

  11. Breast screening using 2D-mammography or integrating digital breast tomosynthesis (3D-mammography) for single-reading or double-reading--evidence to guide future screening strategies.

    PubMed

    Houssami, Nehmat; Macaskill, Petra; Bernardi, Daniela; Caumo, Francesca; Pellegrini, Marco; Brunelli, Silvia; Tuttobene, Paola; Bricolo, Paola; Fantò, Carmine; Valentini, Marvi; Ciatto, Stefano

    2014-07-01

    We compared detection measures for breast screening strategies comprising single-reading or double-reading using standard 2D-mammography or 2D/3D-mammography, based on the 'screening with tomosynthesis or standard mammography' (STORM) trial. STORM prospectively examined screen-reading in two sequential phases, 2D-mammography alone and integrated 2D/3D-mammography, in asymptomatic women participating in Trento and Verona (Northern Italy) population-based screening services. Outcomes were ascertained from assessment and/or excision histology or follow-up. For each screen-reading strategy we calculated the number of detected and non-detected (including interval) cancers, cancer detection rates (CDRs), false positive recall (FPR) measures and incremental CDR relative to a comparator strategy. We estimated the false:true positive (FP:TP) ratio and sensitivity of each mammography screening strategy. Paired binary data were compared using McNemar's test. Amongst 7292 screening participants, there were 65 (including six interval) breast cancers; estimated first-year interval cancer rate was 0.82/1000 screens (95% confidence interval (CI): 0.30-1.79/1000). For single-reading, 35 cancers were detected at both 2D and 2D/3D-mammography, 20 cancers were detected only with 2D/3D-mammography compared with none at 2D-mammography alone (p<0.001) and 10 cancers were not detected. For double-reading, 39 cancers were detected at 2D-mammography and 2D/3D-mammography, 20 were detected only with 2D/3D-mammography compared with none detected at 2D-mammography alone (p<0.001) and six cancers were not detected. The incremental CDR attributable to 2D/3D-mammography (versus 2D-mammography) of 2.7/1000 screens (95% CI: 1.6-4.2) was evident for single and for double-reading. Incremental CDR attributable to double-reading (versus single-reading) of 0.55/1000 screens (95% CI: -0.02-1.4) was evident for 2D-mammography and for 2D/3D-mammography. Estimated FP:TP ratios showed that 2D/3D-mammography

  12. Screening mammography among nursing home residents in the United States: Current guidelines and practice.

    PubMed

    Mack, Deborah S; Epstein, Mara M; Dubé, Catherine; Clark, Robin E; Lapane, Kate L

    2018-06-04

    United States (US) guidelines regarding when to stop routine breast cancer screening remain unclear. No national studies to-date have evaluated the use of screening mammography among US long-stay nursing home residents. This cross-sectional study was designed to identify prevalence, predictors, and geographic variation of screening mammography among that population in the context of current US guidelines. Screening mammography prevalence, identified with Physician/Supplier Part B claims and stratified by guideline age classification (65-74, ≥75 years), was estimated for all women aged ≥65 years residing in US Medicare- and Medicaid- certified nursing homes (≥1 year) with an annual Minimum Data Set (MDS) 3.0 assessment, continuous Medicare Part B enrollment, and no clinical indication for screening mammography as of 2011 (n = 389,821). The associations between resident- and regional- level factors, and screening mammography, were estimated by crude and adjusted prevalence ratios from robust Poisson regressions clustered by facility. Women on average were 85.4 (standard deviation ±8.1) years old, 77.9% were disabled, and 76.3% cognitively impaired. Screening mammography prevalence was 7.1% among those aged 65-74 years (95% Confidence Interval (CI): 6.8%-7.3%) and 1.7% among those ≥75 years (95% CI, 1.7%-1.8%), with geographic variation observed. Predictors of screening in both age groups included race, cognitive impairment, frailty, hospice, and some comorbidities. These results shed light on the current screening mammography practices in US nursing homes. Thoughtful consideration about individual screening recommendations and the implementation of more clear guidelines for this special population are warranted to prevent overscreening. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Monte Carlo Simulation of X-Ray Spectra in Mammography and Contrast-Enhanced Digital Mammography Using the Code PENELOPE

    NASA Astrophysics Data System (ADS)

    Cunha, Diego M.; Tomal, Alessandra; Poletti, Martin E.

    2013-04-01

    In this work, the Monte Carlo (MC) code PENELOPE was employed for simulation of x-ray spectra in mammography and contrast-enhanced digital mammography (CEDM). Spectra for Mo, Rh and W anodes were obtained for tube potentials between 24-36 kV, for mammography, and between 45-49 kV, for CEDM. The spectra obtained from the simulations were analytically filtered to correspond to the anode/filter combinations usually employed in each technique (Mo/Mo, Rh/Rh and W/Rh for mammography and Mo/Cu, Rh/Cu and W/Cu for CEDM). For the Mo/Mo combination, the simulated spectra were compared with those obtained experimentally, and for spectra for the W anode, with experimental data from the literature, through comparison of distribution shape, average energies, half-value layers (HVL) and transmission curves. For all combinations evaluated, the simulated spectra were also compared with those provided by different models from the literature. Results showed that the code PENELOPE provides mammographic x-ray spectra in good agreement with those experimentally measured and those from the literature. The differences in the values of HVL ranged between 2-7%, for anode/filter combinations and tube potentials employed in mammography, and they were less than 5% for those employed in CEDM. The transmission curves for the spectra obtained also showed good agreement compared to those computed from reference spectra, with average relative differences less than 12% for mammography and CEDM. These results show that the code PENELOPE can be a useful tool to generate x-ray spectra for studies in mammography and CEDM, and also for evaluation of new x-ray tube designs and new anode materials.

  14. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    NASA Astrophysics Data System (ADS)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  15. Participation rate or informed choice? Rethinking the European key performance indicators for mammography screening.

    PubMed

    Strech, Daniel

    2014-03-01

    Despite the intensive controversies about the likelihood of benefits and harms of mammography screening almost all experts conclude that the choice to screen or not to screen needs to be made by the individual patient who is adequately informed. However, the "European guideline for quality assurance in breast cancer screening and diagnosis" specifies a participation rate of 70% as the key performance indicator for mammography screening. This paper argues that neither the existing evidence on benefits and harms, nor survey research with women, nor compliance rates in clinical trials, nor cost-effectiveness ratios justify participation rates as a reasonable performance indicator for preference-sensitive condition such as mammography screening. In contrast, an informed choice rate would be more reasonable. Further research needs to address the practical challenges in assessing informed choice rates. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Effect of filter on average glandular dose and image quality in digital mammography

    NASA Astrophysics Data System (ADS)

    Songsaeng, C.; Krisanachinda, A.; Theerakul, K.

    2016-03-01

    To determine the average glandular dose and entrance surface air kerma in both phantoms and patients to assess image quality for different target-filters (W/Rh and W/Ag) in digital mammography system. The compressed breast thickness, compression force, average glandular dose, entrance surface air kerma, peak kilovoltage and tube current time were recorded and compared between W/Rh and W/Ag target filter. The CNR and the figure of merit were used to determine the effect of target filter on image quality. The mean AGD of the W/Rh target filter was 1.75 mGy, the mean ESAK was 6.67 mGy, the mean CBT was 54.1 mm, the mean CF was 14 1bs. The mean AGD of W/Ag target filter was 2.7 mGy, the mean ESAK was 12.6 mGy, the mean CBT was 75.5 mm, the mean CF was 15 1bs. In phantom study, the AGD was 1.2 mGy at 4 cm, 3.3 mGy at 6 cm and 3.83 mGy at 7 cm thickness. The FOM was 24.6, CNR was 9.02 at thickness 6 cm. The FOM was 18.4, CNR was 8.6 at thickness 7 cm. The AGD from Digital Mammogram system with W/Rh of thinner CBT was lower than the AGD from W/Ag target filter.

  17. Digital Mammography and Digital Breast Tomosynthesis.

    PubMed

    Moseley, Tanya W

    2016-06-01

    Breast imaging technology has advanced significantly from the 1930s until the present. American women have a 1 in 8 chance of developing breast cancer. Mammography has been proven in multiple clinical trials to reduce breast cancer mortality. Although a mainstay of breast imaging and improved from film-screen mammography, digital mammography is not a perfect examination. Overlapping obscuring breast tissue limits mammographic interpretation. Breast digital tomosynthesis reduces and/or eliminates overlapping obscuring breast tissue. Although there are some disadvantages with digital breast tomosynthesis, this relatively lost-cost technology may be used effectively in the screening and diagnostic settings.

  18. Mammography dosimetry using an in-house developed polymethyl methacrylate phantom.

    PubMed

    Sharma, Reena; Sharma, Sunil Dutt; Mayya, Y S; Chourasiya, G

    2012-08-01

    Phantom-based measurements in mammography are well-established for quality assurance (QA) and quality control (QC) procedures involving equipment performance and comparisons of X-ray machines. Polymethyl methacrylate (PMMA) is among the best suitable materials for simulation of the breast. For carrying out QA/QC exercises in India, a mammographic PMMA phantom with engraved slots for keeping thermoluminescence dosemeters (TLD) has been developed. The radiation transmission property of the developed phantom was compared with the commercially available phantoms for verifying its suitability for mammography dosimetry. The breast entrance exposure (BEE), mean glandular dose (MGD), percentage depth dose (PDD), percentage surface dose distribution (PSDD), calibration testing of automatic exposure control (AEC) and density control function of a mammography machine were measured using this phantom. MGD was derived from the measured BEE following two different methodologies and the results were compared. The PDD and PSDD measurements were carried out using LiF: Mg, Cu, P chips. The in-house phantom was found comparable with the commercially available phantoms. The difference in the MGD values derived using two different methods were found in the range of 17.5-32.6 %. Measured depth ranges in the phantom lie between 0.32 and 0.40 cm for 75 % depth dose, 0.73 and 0.92 cm for 50 % depth dose, and 1.54 and 1.78 cm for 25 % depth dose. Higher PSDD value was observed towards chest wall edge side of the phantom, which is due to the orientation of cathode-anode axis along the chest wall to the nipple direction. Results obtained for AEC configuration testing shows that the observed mean optical density (O.D) of the phantom image was 1.59 and O.D difference for every successive increase in thickness of the phantom was within±0.15 O.D. Under density control function testing, at -2 and -1 density settings, the variation in film image O.D was within±0.15 O.D of the normal density

  19. Breast cancer screening using tomosynthesis in combination with digital mammography.

    PubMed

    Friedewald, Sarah M; Rafferty, Elizabeth A; Rose, Stephen L; Durand, Melissa A; Plecha, Donna M; Greenberg, Julianne S; Hayes, Mary K; Copit, Debra S; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Miller, Dave P; Conant, Emily F

    2014-06-25

    Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. A total of 454,850 examinations (n=281,187 digital mammography; n=173,663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29,726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15,541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis

  20. Influence of scatter reduction method and monochromatic beams on image quality and dose in mammography.

    PubMed

    Moeckli, Raphaël; Verdun, Francis R; Fiedler, Stefan; Pachoud, Marc; Bulling, Shelley; Schnyder, Pierre; Valley, Jean-François

    2003-12-01

    In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.

  1. Bilateral Contrast-enhanced Dual-Energy Digital Mammography: Feasibility and Comparison with Conventional Digital Mammography and MR Imaging in Women with Known Breast Carcinoma

    PubMed Central

    Dershaw, D. David; Sung, Janice S.; Heerdt, Alexandra S.; Thornton, Cynthia; Moskowitz, Chaya S.; Ferrara, Jessica; Morris, Elizabeth A.

    2013-01-01

    Purpose To determine feasibility of performing bilateral dual-energy (DE) contrast agent–enhanced (CE) digital mammography and to evaluate its performance compared with conventional digital mammography and breast magnetic resonance (MR) imaging in women with known breast cancer. Materials and Methods This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained. Patient accrual began in March 2010 and ended in August 2011. Mean patient age was 49.6 years (range, 25–74 years). Feasibility was evaluated in 10 women with newly diagnosed breast cancer who were injected with 1.5 mL per kilogram of body weight of iohexol and imaged between 2.5 and 10 minutes after injection. Once feasibility was confirmed, 52 women with newly diagnosed cancer who had undergone breast MR imaging gave consent to undergo DE CE digital mammography. Positive findings were confirmed with pathologic findings. Results Feasibility was confirmed with no adverse events. Visualization of tumor enhancement was independent of timing after contrast agent injection for up to 10 minutes. MR imaging and DE CE digital mammography both depicted 50 (96%) of 52 index tumors; conventional mammography depicted 42 (81%). Lesions depicted by using DE CE digital mammography ranged from 4 to 67 mm in size (median, 17 mm). DE CE digital mammography depicted 14 (56%) of 25 additional ipsilateral cancers compared with 22 (88%) of 25 for MR imaging. There were two false-positive findings with DE CE digital mammography and 13 false-positive findings with MR imaging. There was one contralateral cancer, which was not evident with either modality. Conclusion Bilateral DE CE digital mammography was feasible and easily accomplished. It was used to detect known primary tumors at a rate comparable to that of MR imaging and higher than that of conventional digital mammography. DE CE digital mammography had a lower sensitivity for detecting additional ipsilateral

  2. Clinical Evaluation of a Digital Mammography Based on Micro-Lithography (Breast Cancer)

    DTIC Science & Technology

    1994-01-20

    7-9, Mannheim. Schnetztor - V flag; 1992: 90-91. 2. Panizza P., Del Maschio A. Digital Luminescence Mammography. Digital Radiography Workshop: Quality...Assurance and Radiation Protection. May 7-9, Mannheim. Schnetztor - Verlag; 1992:66-67. 3. Panizza P., Cattaneo M., Rodighiero M.G., et al. Course on

  3. Simulation of breast compression in mammography using finite element analysis: A preliminary study

    NASA Astrophysics Data System (ADS)

    Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay

    2017-11-01

    Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.

  4. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    PubMed Central

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    Objective The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. Materials and Methods The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. Results MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). Conclusion CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography. PMID:25469079

  5. Contrast-enhanced spectral mammography: comparison with conventional mammography and histopathology in 152 women.

    PubMed

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography.

  6. Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems

    NASA Astrophysics Data System (ADS)

    Wood, Tim J.; Moore, Craig S.; Saunderson, John R.; Beavis, Andrew W.

    2018-01-01

    Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.

  7. Mammography screening services: market segments and messages.

    PubMed

    Scammon, D L; Smith, J A; Beard, T

    1991-01-01

    Mammography has become a vital tool for the early detection of breast cancer. Although many organizations and health care facilities are working to educate and motivate women to take advantage of the life saving opportunity that is offered through screening mammography, only twenty percent of women who should be screened actually have the procedure performed. In order to reach women who have not been screened, it is important to learn which factors most strongly motivate those women who do choose to have a mammogram. Depth interviews with 18 women attending a mobile mammography unit were conducted to explore the decision making process of women obtaining mammography screening services and to develop a profile of prevalent emotions, attitudes, and feelings associated with receiving breast cancer screening services. Analysis of the interview transcripts revealed several important themes to which health care professionals can direct marketing and health promotion strategies.

  8. Beliefs of Turkish female teaching staff regarding mammography scanning.

    PubMed

    Temel, Ayla Bayik; Ardahan, Melek; Sesli, Esra

    2010-01-01

    To our knowledge, there has hitherto been no research to determine the beliefs of female teaching staff, who are highly educated and form a special risk group regarding breast cancer, towards mammography scanning in Turkey. Definitive research was planned to determine the beliefs of the female teaching staff working in a university. Data were collected by researchers via face-to-face interview using a sociodemographic questionnaire and " Health Belief Model ". The point average of the teaching staff in the mammography benefits sub-scale is 19.6 ± 3.87, their average item score is 3.91. The point average of the teaching staff in the mammography obstacles sub-scale is 21.17 ± 6.87, their average item score is 1.92. They agree on the benefits of the mammography, but they do not agree on the obstacles to mammography.

  9. Beyond Mammography: New Frontiers in Breast Cancer Screening

    PubMed Central

    Drukteinis, Jennifer S.; Mooney, Blaise P.; Flowers, Chris I.; Gatenby, Robert A

    2014-01-01

    Breast cancer screening remains a subject of intense and, at times, passionate debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography has also undergone increased scrutiny for false positives and excessive biopsies, which increase radiation dose, cost and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including; low dose mammography; contrast enhanced mammography, tomosynthesis, automated whole breast ultrasound, molecular imaging and MRI. Here we examine some of the current controversies and promising new technologies that may improve detection of breast cancer both in the general population and in high-risk groups, such as women with dense breasts. We propose that optimal breast cancer screening will ultimately require a personalized approach based on metrics of cancer risk with selective application of specific screening technologies best suited to the individual’s age, risk, and breast density. PMID:23561631

  10. Prospective study aiming to compare 2D mammography and tomosynthesis + synthesized mammography in terms of cancer detection and recall. From double reading of 2D mammography to single reading of tomosynthesis.

    PubMed

    Romero Martín, Sara; Raya Povedano, Jose Luis; Cara García, María; Santos Romero, Ana Luz; Pedrosa Garriguet, Margarita; Álvarez Benito, Marina

    2018-06-01

    To evaluate tomosynthesis compared with 2D-mammography in cancer detection and recalls in a screening-programme, and assess performing synthesized instead of 2D, and compare double reading of 2D with single reading of tomosynthesis. Women (age 50-69 years) participating in the screening-programme were included. 2D-mammography and tomosynthesis were performed. There were four reading models: 2D-mammography (first); 2D-mammography (second); tomosynthesis + synthesized (third); tomosynthesis + synthesized + 2D (fourth reading). Paired double reading of 2D (first+second) and tomosynthesis (third+fourth) were analysed. In 16,067 participants, there were 98 cancers and 1,196 recalls. Comparing double reading of 2D with single reading of tomosynthesis, there was an increase of 12.6 % in cancer detection with the third reading (p= 0.043) and 6.9 % with the fourth reading (p=0.210), and a decrease in recalls of 40.5 % (p<0.001) and 44.4 % (p<0.001), respectively. With double reading of both techniques, there was an increase in cancer detection of 17.4 % (p = 0.004) and a decrease in recalls of 12.5 % (p = 0.001) with tomosynthesis. Single reading of tomosynthesis plus synthesized increased cancer detection and decreased recalls compared with double reading 2D. 2D did not improve results when added to tomosynthesis. • Tomosynthesis increases cancer detection and decreases recall rates versus 2D mammography. • Synthesized-mammography avoids performing 2D, showing higher cancer detection. • Single reading of tomosynthesis + synthesized is feasible as a new practice.

  11. Factors that influence mammography screening behaviour: a qualitative study of Greek women's experiences.

    PubMed

    Kaltsa, Aikaterina; Holloway, Aisha; Cox, Karen

    2013-06-01

    To identify the factors that influence mammography screening behaviour in a sample of Greek women. Data were collected in Athens-Greece, from individuals who were members of six women's associations. A subset of 33 women were interviewed about their screening behaviour and experiences out of the 186 women who completed an initial questionnaire. This paper focuses on the findings revealed from the interviews. Women's associations were approached for the recruitment of the interviewees. Influences arising from women's immediate networks, such as family and close friends, appeared to be of essential importance in relation to their screening behaviour, while influences from their broader networks were of moderate impact. Fear acted as a motivator but also as a barrier in relation to mammography screening participation. Experiences that arose from engagement with the mammography screening processes were mostly characterized by having to overcome a variety of obstacles, such as long bureaucratic procedures and distrust in doctors. The interpersonal relationships between women and their social networks appeared to have an important and influential role in relation to breast screening behaviour. The quality of these relationships appeared to determine women's participation in mammography screening. It would appear that future practice needs to focus on these relationships in order to utilize them in a positive way. Future research is needed to explore this further. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Mammography: an update of the EUSOBI recommendations on information for women.

    PubMed

    Sardanelli, Francesco; Fallenberg, Eva M; Clauser, Paola; Trimboli, Rubina M; Camps-Herrero, Julia; Helbich, Thomas H; Forrai, Gabor

    2017-02-01

    This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a small number of women who undergo the test. Information is given on the recall during a screening programme and on the request for further work-up after a diagnostic mammography. The logic of the mammography report and of classification systems such as R1-R5 and BI-RADS is illustrated, and brief but clear information is given about the diagnostic performance of the test, with particular reference to interval cancers, i.e., those cancers that are missed at screening mammography. Moreover, the breast cancer risk due to radiation exposure from mammography is compared to the reduction in mortality obtained with the test, and the concept of overdiagnosis is presented with a reliable estimation of its extent. Information about new mammographic technologies (tomosynthesis and contrast-enhanced spectral mammography) is also given. Finally, frequently asked questions are answered. • Direct digital mammography should be preferred to film-screen or phosphor plates. • Screening (in asymptomatic women) should be distinguished from diagnosis (in symptomatic women). • A breast symptom has to be considered even after a negative mammogram. • Digital breast tomosynthesis increases cancer detection and decreases the recall rate. • Contrast-enhanced spectral mammography can help in cancer detection and lesion characterisation.

  13. Toward a standard reference database for computer-aided mammography

    NASA Astrophysics Data System (ADS)

    Oliveira, Júlia E. E.; Gueld, Mark O.; de A. Araújo, Arnaldo; Ott, Bastian; Deserno, Thomas M.

    2008-03-01

    Because of the lack of mammography databases with a large amount of codified images and identified characteristics like pathology, type of breast tissue, and abnormality, there is a problem for the development of robust systems for computer-aided diagnosis. Integrated to the Image Retrieval in Medical Applications (IRMA) project, we present an available mammography database developed from the union of: The Mammographic Image Analysis Society Digital Mammogram Database (MIAS), The Digital Database for Screening Mammography (DDSM), the Lawrence Livermore National Laboratory (LLNL), and routine images from the Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen. Using the IRMA code, standardized coding of tissue type, tumor staging, and lesion description was developed according to the American College of Radiology (ACR) tissue codes and the ACR breast imaging reporting and data system (BI-RADS). The import was done automatically using scripts for image download, file format conversion, file name, web page and information file browsing. Disregarding the resolution, this resulted in a total of 10,509 reference images, and 6,767 images are associated with an IRMA contour information feature file. In accordance to the respective license agreements, the database will be made freely available for research purposes, and may be used for image based evaluation campaigns such as the Cross Language Evaluation Forum (CLEF). We have also shown that it can be extended easily with further cases imported from a picture archiving and communication system (PACS).

  14. Barriers to Mammography among Inadequately Screened Women

    ERIC Educational Resources Information Center

    Stoll, Carolyn R. T.; Roberts, Summer; Cheng, Meng-Ru; Crayton, Eloise V.; Jackson, Sherrill; Politi, Mary C.

    2015-01-01

    Mammography use has increased over the past 20 years, yet more than 30% of women remain inadequately screened. Structural barriers can deter individuals from screening, however, cognitive, emotional, and communication barriers may also prevent mammography use. This study sought to identify the impact of number and type of barriers on mammography…

  15. Research in action: mammography utilization following breast cancer awareness campaigns in Lebanon 2002-05.

    PubMed

    Adib, S M; Sabbah, M A; Hlais, S; Hanna, P

    2009-01-01

    Four consecutive annual surveys of 1200 women each were conducted in Lebanon in connection with the National Breast Cancer Awareness campaigns (2002-05) to measure the prevalence of mammography utilization and the impact of these campaigns, and to highlight regional and demographic differences. The utilization of mammography in the previous 12 months was low and increased only slightly over 4 years (from 11% to 18%). In the 2005 campaign, it was twice as high (25%) in greater Beirut than in mostly rural areas, and among women aged 40-59 years (about 21%) compared with younger (12%) or older (11%) women. In each wave, repeat mammograms were less common than first time screening.

  16. Mammography screening among Arab American women in metropolitan Detroit.

    PubMed

    Schwartz, Kendra; Fakhouri, Monty; Bartoces, Monina; Monsur, Joseph; Younis, Amani

    2008-12-01

    Mammography screening behavior has not been well studied among Middle Eastern immigrant women. We conducted a telephone survey of 365 Arab American women residing in metropolitan Detroit, home to one of the largest populations of Middle Eastern immigrants in the US, to determine prevalence of factors associated with mammography, and attitudes and beliefs regarding mammography screening. Of 365 participants, only five were born in the US. Mean age was 53.2 years (SD 10.8). Two hundred twelve (58.1%) reported having mammogram every 1-2 years; 70% ever had mammogram. Age 50-64 years, having health insurance, married status, being in the US over 10 years, and being Lebanese were associated with mammography every 1-2 years. After adjusting for demographic factors, perceived seriousness of disease, general health motivation, and having fewer barriers were associated with more frequent screening. Appropriate mammography screening is decreased in this group. Targeted outreach regarding screening is appropriate for this population; however, lack of insurance may prevent adequate follow-up.

  17. Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

    PubMed

    Cheung, Yun-Chung; Lin, Yu-Ching; Wan, Yung-Liang; Yeow, Kee-Min; Huang, Pei-Chin; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chang, Chee-Jen

    2014-10-01

    To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). CESM cases of dense breasts with histological proof were evaluated in the present study. Four radiologists with varying experience in mammography interpretation blindly read Mx first, followed by CESM. The diagnostic profiles, consistency and learning curve were analysed statistically. One hundred lesions (28 benign and 72 breast malignancies) in 89 females were analysed. Use of CESM improved the cancer diagnosis by 21.2 % in sensitivity (71.5 % to 92.7 %), by 16.1 % in specificity (51.8 % to 67.9 %) and by 19.8 % in accuracy (65.9 % to 85.8 %) compared with Mx. The interobserver diagnostic consistency was markedly higher using CESM than using Mx alone (0.6235 vs. 0.3869 using the kappa ratio). The probability of a correct prediction was elevated from 80 % to 90 % after 75 consecutive case readings. CESM provided additional information with consistent improvement of the cancer diagnosis in dense breasts compared to Mx alone. The prediction of the diagnosis could be improved by the interpretation of a significant number of cases in the presence of 6 % benign contrast enhancement in this study. • DE-CESM improves the cancer diagnosis in dense breasts compared with mammography. • DE-CESM shows greater consistency than mammography alone by interobserver blind reading. • Diagnostic improvement of DE-CESM is independent of the mammographic reading experience.

  18. MRI and mammography surveillance of women at increased risk for breast cancer: recommendations using an evidence-based approach.

    PubMed

    Granader, Elon J; Dwamena, Ben; Carlos, Ruth C

    2008-12-01

    To evaluate breast cancer screening with mammography and magnetic resonance imaging (MRI) in high-risk populations, including women with the BRCA mutation, using an evidence-based approach. The MEDLINE, PubMed, EBM Reviews, ACP Journal Club, Cochrane Database MEDSEARCH, and SCOPUS databases were accessed and searched for articles up to August 2007. Articles were collected using the following terms and medical subject headings (MeSH) that applied to the focused clinical question: "BRCA1" and "BRCA2" with "mammography," "MRI," "prevention," "screening," and "surveillance." References from retrieved articles were also used to identify relevant papers. Abstracts were screened and relevant papers retrieved. Retrieved papers were graded for quality. Summary performance measures were obtained by random effects modeling of study-specific performance estimates and standard errors derived from the multiple 2 x 2 tables. Additionally, studies meeting the Centre for Evidence-Based Medicine level 2b quality were reviewed. In women with an increased risk without the BRCA gene, cancer detection rates by MRI were 0.011 (95% confidence interval [CI] 0.003-0.019), by mammography 0.005 (95% CI 0.002-0.008), and by a combination of both, 0.012 (95% CI 0.004-0.020). False-positive rates by MRI, mammography, or a combination of both were 0.10 (95% CI 0.03-0.18), 0.05 (95% CI 0.03-0.06), and 0.14 (95% CI 0.04-0.24). In BRCA positive women, cancer detection rates by MRI were 0.027 (95% CI 0.015-0.040), by mammography 0.010 (95% CI 0.005-0.016), and by a combination of both 0.031 (95% CI 0.018-0.045). False-positive rates by MRI, mammography, or a combination of both were 0.10 (95% CI 0.01-0.19), 0.05 (95% CI 0.03-0.07), and 0.14 (95% CI 0.04-0.24), respectively. The data support an essential role for screening MRI in women with an increased risk for breast cancer.

  19. Correlates of mammography utilization among working Muslim Iranian women.

    PubMed

    Hatefnia, Effat; Niknami, Shamsaddin; Bazargan, Mohsen; Mahmoodi, Mahmood; Lamyianm, Minoor; Alavi, Nasrien

    2010-06-01

    Most countries in Middle East have been successful in establishing and furthering basic facilities for screening, diagnosis, and treatment of breast cancer. The rate of compliance with mammography screening, however, remains well below North American and Western European countries. We utilized the Health Belief Model (HBM) to explore factors associated with mammography screening behavior among a sample of 320 Muslim women aged > or = 35. Carrying out this cross-sectional study, we found that screening behavior was associated with older age, higher perceived benefit of breast cancer screening, and lower perceived barrier. Additionally, we demonstrate the importance of religious beliefs in influencing mammography screening behavior and explaining the link between religious involvement and mammography behavior.

  20. Influence of advertisement on women's attitudes toward mammography screening.

    PubMed

    Collins, C; Davis, L S; Rentz, K; Vannoy, D

    1997-01-01

    This project represents an effort to incorporate a feminist perspective into research on mammography screening. The purpose of this study was to assess women's attitudes toward four advertisements designed to encourage mammography screening. The goal was to create awareness about women's attitudes toward mammography advertisements in order to encourage the development of more effective and responsive motivational materials. The results indicated that each ad communicated different messages about the seriousness of breast cancer and the efficacy of mammography in detecting early breast cancer. Each ad also affected women differently regarding their feelings of control over breast cancer, their perceived loss of sex appeal resulting from a breast cancer diagnosis, and their general fear of breast cancer.

  1. A review of screening mammography participation and utilization in Canada.

    PubMed

    Doyle, G P; Major, D; Chu, C; Stankiewicz, A; Harrison, M L; Pogany, L; Mai, V M; Onysko, J

    2011-09-01

    Participation rate is an important indicator for a screening program's effectiveness; however, the current approach to measuring participation rate in Canada is not comparable with other countries. The objective of this study is to review the measurement of screening mammography participation in Canada, make international comparisons, and propose alternative methods. Canadian breast cancer screening program data for women aged 50 to 69 years screened between 2004 and 2006 were extracted from the Canadian Breast Cancer Screening Database (CBCSD). The fee-for-services (FSS) mammography data (opportunistic screening mammography) were obtained from the provincial ministries of health. Both screening mammography program participation and utilization were examined over 24 and 30 months. Canada's screening participation rate increases from 39.4% for a 24-month cut-off to 43.6% for a 30-month cut-off. The 24-month mammography utilization rate is 63.1% in Canada, and the 30-month utilization rate is 70.4%. Due to the differences in health service delivery among Canadian provinces, both programmatic participation and overall utilization of mammography at 24 months and 30 months should be monitored.

  2. Readability assessment of internet-based patient education materials related to mammography for breast cancer screening.

    PubMed

    AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil

    2015-03-01

    The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  3. Understanding women's mammography intentions: a theory-based investigation.

    PubMed

    Naito, Mikako; O'Callaghan, Frances V; Morrissey, Shirley

    2009-01-01

    The present study compared the utility of two models (the Theory of Planned Behavior and Protection Motivation Theory) in identifying factors associated with intentions to undertake screening mammography, before and after an intervention. The comparison was made between the unique components of the two models. The effect of including implementation intentions was also investigated. Two hundred and fifty-one women aged 37 to 69 years completed questionnaires at baseline and following the delivery of a standard (control) or a protection motivation theory-based informational intervention. Hierarchical multiple regressions indicated that theory of planned behavior variables were associated with mammography intentions. Results also showed that inclusion of implementation intention in the model significantly increased the association with mammography intentions. The findings suggest that future interventions aiming to increase screening mammography participation should focus on the theory of planned behavior variables and that implementation intention should also be targeted.

  4. Improving mammography screening among the medically underserved.

    PubMed

    Davis, Terry C; Rademaker, Alfred; Bennett, Charles L; Wolf, Michael S; Carias, Edson; Reynolds, Cristalyn; Liu, Dachao; Arnold, Connie L

    2014-04-01

    We evaluated the effectiveness and cost-effectiveness of alternative interventions designed to promote mammography in safety-net settings. A three-arm, quasi-experimental evaluation was conducted among eight federally qualified health clinics in predominately rural Louisiana. Mammography screening efforts included: 1) enhanced care, 2) health literacy-informed education of patients, and 3) education plus nurse support. Outcomes included mammography screening completion within 6 months and incremental cost-effectiveness. Overall, 1,181 female patients ages 40 and over who were eligible for routine mammography were recruited. Baseline screening rates were < 10%. Post intervention screening rates were 55.7% with enhanced care, 51.8% with health literacy-informed education and 65.8% with education and nurse support. After adjusting for race, marital status, self-efficacy and literacy, patients receiving health-literacy informed education were not more likely to complete mammographic screening than those receiving enhanced care; those additionally receiving nurse support were 1.37-fold more likely to complete mammographic screening than those receiving the brief education (95% Confidence Interval 1.08-1.74, p = 0.01). The incremental cost per additional women screened was $2,457 for literacy-informed education with nurse support over literacy-informed education alone. Mammography rates were increased substantially over existing baseline rates in all three arms with the educational initiative, with nurse support and follow-up being the most effective option. However, it is not likely to be cost-effective or affordable in resource-limited clinics.

  5. National Recommended Water Quality Criteria

    EPA Pesticide Factsheets

    The National Recommended Water Quality Criteria is a compilation of national recommended water quality criteria for the protection of aquatic life and human health in surface water for approximately 150 pollutants. These criteria provide guidance for states and tribes to use in adopting water quality standards.

  6. The Future of Contrast-Enhanced Mammography.

    PubMed

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  7. Diagnostic quality of 50 and 100 µm computed radiography compared with screen–film mammography in operative breast specimens

    PubMed Central

    Pagliari, C M; Hoang, T; Reddy, M; Wilkinson, L S; Poloniecki, J D; Given-Wilson, R M

    2012-01-01

    Objective To compare reader ratings of the clinical diagnostic quality of 50 and 100 μm computed radiography (CR) systems with screen–film mammography (SFM) in operative specimens. Methods Mammograms of 57 fresh operative breast specimens were analysed by 10 readers. Exposures were made with identical position and compression with three mammographic systems (Fuji 100CR, 50CR and SFM). Images were anonymised and readers blinded to the CR system used. A five-point comparative scoring system (−2 to +2) was used to assess seven quality criteria and overall diagnostic value. Statistical analysis was subsequently performed of reader ratings (n=16 925). Results For most quality criteria, both CR systems were rated as equivalent to or better than SFM. The CR systems were significantly better at demonstrating skin edge and background tissue (p<1×10−5). Microcalcification was best demonstrated on the CR50 system (p<1×10−5). The overall diagnostic value of both CR systems was rated as being as good as or better than SFM (p<1×10−5). Conclusion In this clinical setting, the overall diagnostic performance of both CR systems was as good as or better than SFM, with the CR50 system performing better than the CR100. PMID:22096218

  8. Radiation protection program for early detection of breast cancer in a mammography facility

    NASA Astrophysics Data System (ADS)

    Villagomez Casimiro, Mariana; Ruiz Trejo, Cesar; Espejo Fonseca, Ruby

    2014-11-01

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1-4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)- presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.

  9. Radiation protection program for early detection of breast cancer in a mammography facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mariana, Villagomez Casimiro, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Cesar, Ruiz Trejo, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Ruby, Espejo Fonseca

    Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systemsmore » (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.« less

  10. EPA National Quality System Contacts

    EPA Pesticide Factsheets

    Web links and contacts for the individual quality systems developed in support of the EPA Quality System by each EPA Regional Office, National Program Office and ORD National Research Laboratory and Center.

  11. Technetium-99m sestamibi scintimammography complements mammography in the detection of breast cancer.

    PubMed

    Krishnaiah, Gayathri; Sher-Ahmed, Arifa; Ugwu-Dike, Martins; Regan, Patricia; Singer, John; Totoonchie, Adil; Spiegler, Ethan; Sardi, Armando

    2003-01-01

    Mammography remains the technique of choice for the detection of early breast cancer. The sensitivity of mammography is 85%, but is decreased in patients with dense breasts. Sestamibi scintimammography (SCM) has been suggested as an adjunctive modality to improve the detection of breast cancer. We conducted a study to determine the impact of SCM in patient management. A prospective study was conducted in 95 patients presenting with palpable masses and/or abnormal mammography scheduled for biopsy. Injection of 20-30 mCi of technetium-99m (Tc-99m) sestamibi into a pedal vein was performed. Ten-minute images of the breast and axilla were obtained in multiple projections. The mammography and SCM were correlated with pathology and clinical findings. The median age was 44 years (range 28-86 years). The total number of lesions was 104, as eight patients had bilateral lesions and one patient had two lesions in the same breast. Fifty-nine patients presented with palpable lesions and 45 patients with nonpalpable lesions (42 with abnormal mammography only and 3 with nipple discharge). A comparison of sensitivity, specificity, positive and negative predictive values, and overall accuracy of SCM and mammography were performed. The sensitivity and specificity for SCM were 83% and 83%, respectively, and for mammography were 65%, and 72%, respectively. The sensitivity and specificity for combined SCM and mammography were 87% and 94%, respectively. The p-value for mammography versus combined SCM and mammography was 0.0003 and that for SCM versus SCM and mammography was 0.0098. There were 80 (77%) benign and 24 (23%) malignant lesions. Of the 24 malignancies, SCM missed six (25%), versus eight (33%) by mammography. In two patients (9%) SCM detected malignancy in the breast that was not visualized by mammography or found on clinical examination. Sestamibi SCM improves the sensitivity of mammography and it detects up to 9% of malignancies not detected by mammography or clinical

  12. Mammography facilities are accessible, so why is utilization so low?

    PubMed

    Mobley, Lee R; Kuo, Tzy-Mey May; Clayton, Laurel J; Evans, W Douglas

    2009-08-01

    This study examines new socio-ecological variables reflecting community context as predictors of mammography use. The conceptual model is a hybrid of traditional health-behavioral and socio-ecological constructs with an emphasis on spatial interaction among women and their environments, differentiating between several levels of influence for community context. Multilevel probability models of mammography use are estimated. The study sample includes 70,129 women with traditional Medicare fee-for-service coverage for inpatient and outpatient services, drawn from the SEER-Medicare linked data. The study population lives in heterogeneous California, where mammography facilities are dense but utilization rates are low. Several contextual effects have large significant impacts on the probability of mammography use. Women living in areas with higher proportions of elderly in poverty are 33% less likely to use mammography. However, dually eligible women living in these poor areas are 2% more likely to use mammography than those without extra assistance living in these areas. Living in areas with higher commuter intensity, higher violent crime rates, greater land use mix (urbanicity), or more segregated Hispanic communities exhibit -14%, -1%, -6%, and -3% (lower) probability of use, respectively. Women living in segregated American Indian communities or in communities where more elderly women live alone exhibit 16% and 12% (higher) probability of use, respectively. Minority women living in more segregated communities by their minority are more likely to use mammography, suggesting social support, but this is significant for Native Americans only. Women with disability as their original reason for entitlement are found 40% more likely to use mammography when they reside in communities with high commuter intensity, suggesting greater ease of transportation for them in these environments. Socio-ecological variables reflecting community context are important predictors of

  13. Method for inserting noise in digital mammography to simulate reduction in radiation dose

    NASA Astrophysics Data System (ADS)

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Vieira, Marcelo A. C.

    2015-03-01

    The quality of clinical x-ray images is closely related to the radiation dose used in the imaging study. The general principle for selecting the radiation is ALARA ("as low as reasonably achievable"). The practical optimization, however, remains challenging. It is well known that reducing the radiation dose increases the quantum noise, which could compromise the image quality. In order to conduct studies about dose reduction in mammography, it would be necessary to acquire repeated clinical images, from the same patient, with different dose levels. However, such practice would be unethical due to radiation related risks. One solution is to simulate the effects of dose reduction in clinical images. This work proposes a new method, based on the Anscombe transformation, which simulates dose reduction in digital mammography by inserting quantum noise into clinical mammograms acquired with the standard radiation dose. Thus, it is possible to simulate different levels of radiation doses without exposing the patient to new levels of radiation. Results showed that the achieved quality of simulated images generated with our method is the same as when using other methods found in the literature, with the novelty of using the Anscombe transformation for converting signal-independent Gaussian noise into signal-dependent quantum noise.

  14. WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gingold, E; Karellas, A; Strauss, K

    Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years hasmore » changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice

  15. Differential Effects of Social Networks on Mammography Use by Poverty Status.

    PubMed

    Yeo, Younsook

    2016-01-01

    This study examines whether social networks have differential effects on mammography use depending on poverty status. Data were analyzed on US women (40+), employing logistic regression and simple slope analyses for a post hoc probing of moderating effects. Among women not in poverty, living with a spouse/partner and attending church, regardless of frequency, were positively associated with mammography use; family size was negatively associated. Among women living in poverty, mammography showed a positive association only with weekly church attendance. Mammography was negatively associated with health-related social interactions occurring through the Internet. Post hoc probing showed significant moderating effects of poverty on the relationship between online health-related interactions and mammography use. To make the Internet a meaningful health empowerment tool for women in poverty, future research should identify how health-related interactions that occur online affect women in poverty's psychological and behavioral reactions that will contribute to our understanding of why they are discouraged from having mammograms. The mechanisms behind the differential effects of church attendance and poverty status on mammography also need further clarification.

  16. Mammography screening: how important is cost as a barrier to use?

    PubMed Central

    Urban, N; Anderson, G L; Peacock, S

    1994-01-01

    OBJECTIVES. Recent legislation will improve insurance coverage for screening mammography and effectively lower its cost to many women. Although cost has been cited as a barrier to use, evidence of the magnitude of its effect on use is limited. METHODS. Mammography use in the past 2 years among women aged 50 to 75 residing in four suburban or rural counties in Washington State was estimated from 1989 survey data. Logistic regression analysis was used to estimate the odds ratio of mammography use as a function of economic and other variables. Within a residential area, averages were used to measure the market price of mammography and the time cost to obtain a mammogram. RESULTS. Use was lower among women who faced a higher net price or who preferred to obtain a mammogram during weekend or evening hours and higher among women with higher incomes. Visiting no doctor regularly and smoking were predictors of failure to use mammography. CONCLUSION. The effects of economic variables on mammography use are important and stable across subsets of the population, but they are modest in size. PMID:8279611

  17. Mammography screening: how important is cost as a barrier to use?

    PubMed

    Urban, N; Anderson, G L; Peacock, S

    1994-01-01

    Recent legislation will improve insurance coverage for screening mammography and effectively lower its cost to many women. Although cost has been cited as a barrier to use, evidence of the magnitude of its effect on use is limited. Mammography use in the past 2 years among women aged 50 to 75 residing in four suburban or rural counties in Washington State was estimated from 1989 survey data. Logistic regression analysis was used to estimate the odds ratio of mammography use as a function of economic and other variables. Within a residential area, averages were used to measure the market price of mammography and the time cost to obtain a mammogram. Use was lower among women who faced a higher net price or who preferred to obtain a mammogram during weekend or evening hours and higher among women with higher incomes. Visiting no doctor regularly and smoking were predictors of failure to use mammography. The effects of economic variables on mammography use are important and stable across subsets of the population, but they are modest in size.

  18. Socio-Cognitive Determinants of the Mammography Screening Uptake among Iranian Women

    PubMed

    Mirzaei-Alavijeh, Mehdi; Ghorbani, Parvaneh; Jalilian, Farzad

    2018-05-26

    Background: Mammography screening uptake is the most effective method in breast cancer screening. The aim of this study was to determine the determinants related to mammography screening uptake among Iranian women based on the theory of planned behavior. Materials and Methods: This cross-sectional study was conducted among 408 women who referred to health centers in Kermanshah city, the western of Iran, during 2016. Participants filled out a self-administered questionnaire. Data were analyzed by SPSS version 21 using Pearson correlation, linear and logistic regression statistical tests at 95% significant level. Results: The mean age of participants was 39.61 years [SD: 8.28], ranged from 30 to 60 years. Almost 13% of the participants had already mammography screening uptake at least once. Perceived behavioral control (OR=1.229) and behavioral intention (OR=1.283) were the more influential predictors on mammography screening uptake. Conclusions: Based on result, it seems increase perceived behavior control toward mammography screening uptake may be usefulness in promotion of mammography screening uptake among Iranian women. Creative Commons Attribution License

  19. Mammography and Other Screening Tests for Breast Problems

    MedlinePlus

    ... in eight women will develop breast cancer by age 75 years. Regular breast screening can help find cancer at an early and more curable stage. Screening also can find problems in the breasts that are not cancer. What is mammography? Mammography is the primary tool used to screen for breast cancer and ...

  20. The relationship between breast cancer anxiety and mammography: experiential avoidance as a moderator.

    PubMed

    Miller, Sarah J; O'Hea, Erin L; Lerner, Jennifer Block; Moon, Simon; Foran-Tuller, Kelly A

    2011-10-01

    Although mammography can aid in the early detection and prevention of breast cancer, many women do not receive annual mammograms. It remains unclear whether anxiety about breast cancer inhibits or promotes mammography rates. The way in which women regulate their anxiety (ie, level of experiential avoidance) may play a role in predicting mammography adherence. A community sample of women (N = 84) completed a questionnaire which assessed mammography rates, experiential avoidance, and breast cancer anxiety. The results suggest that, while controlling for breast cancer anxiety, experiential avoidance (β = .31, p < .01) significantly predicted mammography rates. When examining experiential avoidance as a moderator, a multiple regression analysis approached significance (R2 Δ = .04, p = .07), suggesting that a woman's level of experiential avoidance influences the relationship between anxiety and mammography. These findings will help enable health care practitioners to better identify women at risk of non-adherence to mammography recommendations.

  1. Shielding requirements for mammography.

    PubMed

    Simpkin, D J

    1987-09-01

    Shielding requirements for mammography installations have been investigated. To apply the methodologies of NCRP Report No. 49, the scatter-to-incident ratio of a typical mammography beam was measured, and the broad beam transmission was calculated for several representative beam spectra. These calculations were found to compare favorably with published low kVp tungsten-targeted x-ray transmission through a variety of shielding materials. Radiation shielding tables were developed from the calculated transmissions through Pb, concrete, gypsum, steel, plate glass, and water, using a technique which eliminates the "add one HVL" rule. It is concluded that Mo-targeted x-ray beams operated at 35 kVp require half the shielding of W-targeted beams operated at 50 kVp, and that adequate, cost-effective shielding calculations will consider alternatives to Pb.

  2. Psychosocial Determinants of Mammography Follow-up after Receipt of Abnormal Mammography Results in Medically Underserved Women

    PubMed Central

    Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M.; Grau, Ana M.; Champion, Victoria L.; Wallston, Kenneth A.

    2010-01-01

    This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR = 2.53, 95% CI = 1.12–5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value = .02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted. PMID:20173286

  3. Psychosocial determinants of mammography follow-up after receipt of abnormal mammography results in medically underserved women.

    PubMed

    Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M; Grau, Ana M; Champion, Victoria L; Wallston, Kenneth A

    2010-02-01

    This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR=2.53, 95% CI=1.12-5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value=.02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted.

  4. The Future of Mammography: Radiology Residents’ Experiences, Attitudes, and Opinions

    PubMed Central

    Baxi, Shrujal S.; Snow, Jacqueline G.; Liberman, Laura; Elkin, Elena B.

    2011-01-01

    OBJECTIVE The objective of our study was to assess the experiences and preferences of radiology residents with respect to breast imaging. MATERIALS AND METHODS We surveyed radiology residents at 26 programs in New York and New Jersey. Survey topics included plans for subspecialty training, beliefs, and attitudes toward breast imaging and breast cancer screening and the likelihood of interpreting mammography in the future. RESULTS Three hundred forty-four residents completed the survey (response rate, 62%). The length of time spent training in breast imaging varied from no dedicated time (37%) to 1–8 weeks (40%) to more than 9 weeks (23%). Most respondents (97%) agreed that mammography is important to women’s health. More than 85% of residents believed that mammography should be interpreted by breast imaging specialists. Respondents shared negative views about mammography, agreeing with statements that the field was associated with a high risk of malpractice (99%), stress (94%), and low reimbursement (68%). Respondents endorsed several positive attributes of mammography, including job availability (97%), flexible work schedules (94%), and few calls or emergencies (93%). Most radiology residents (93%) said that they were likely to pursue subspecialty training, and 7% expressed interest in breast imaging fellowships. CONCLUSION Radiology residents’ negative and positive views about mammography seem to be independent of time spent training in mammography and of future plans to pursue fellowship training in breast imaging. Systematic assessment of the plans and preferences of radiology residents can facilitate the development of strategies to attract trainees to careers in breast imaging. PMID:20489113

  5. The relationship of social support concept and repeat mammography among Iranian women.

    PubMed

    Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy

    2015-10-24

    Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P < 0.006). The probability of repeat mammography in women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P < 0.0001). Iranian women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.

  6. Digital Mammography with a Mosaic of CCD-Arrays

    NASA Technical Reports Server (NTRS)

    Jalink, Antony, Jr. (Inventor); McAdoo, James A. (Inventor)

    1996-01-01

    The present invention relates generally to a mammography device and method and more particularly to a novel digital mammography device and method to detect microcalcifications of precancerous tissue. A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays. The novelty of this invention is that it provides a digital mammography device with large field coverage, high spatial resolution, scatter rejection, excellent contrast characteristics and lesion detectability under clinical conditions. This device also shields the patient from excessive radiation, can detect extremely small calcifications and allows manipulation and storage of the image.

  7. Motivators and barriers to mammography screening uptake by female health-care workers in primary health-care centres: a cross-sectional study.

    PubMed

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha B; Sholi, Mohammad B; Lahaseh, Rawya

    2018-02-21

    Mammography screening is an effective tool for early detection and management of breast cancer. Female health-care workers' awareness of breast cancer screening is important because their beliefs and behaviours could influence other women. The aim of this study was to assess mammography screening uptake by female health-care workers at primary health-care centres and to identify the primary motivators and barriers that affect uptake. This cross-sectional study included all governmental primary health-care centres in the West Bank. Governorates were grouped into three regions as follows: north West Bank (Nablus, Jenin, Tulkarm, Tubas, Qalqiliya, and Salfit), middle West Bank (Jerusalem, Jericho, and Ramallah), and south West Bank (Hebron, and Bethlehem). The study population included all female health-care workers older than 40 years. Those who performed mammography for a suspected mass or other breast abnormalities were excluded. A self-administered questionnaire was used to collect data on demographic characteristics, knowledge about mammography screening, the extent and regularity of mammography screening, and motivators and barriers influencing their mammography screening uptake. The rate of mammography screening uptake was calculated. χ 2 test and t tests were used to assess screening motivators and barriers. The study was approved by the Institutional Review Board of the An-Najah National University. Participation was voluntary, and written consent was obtained from each participant. 299 female health-care workers completed a self-administered questionnaire. The mean age of the participants was 46 years (SD 4·7). 284 (95%) women had adequate knowledge about breast cancer and mammography screening, and 149 (50%) women reported having had at least one mammogram. 62 (21%) women had had regular scheduled mammograms. The most frequent reported motivators were the perceived benefit that early detection of breast cancer is important for its management (269 [90

  8. Measuring preparedness for mammography in women with intellectual disabilities: a validation study of the Mammography Preparedness Measure.

    PubMed

    Wang, Claire Tienwey; Greenwood, Nechama; White, Laura F; Wilkinson, Joanne

    2015-05-01

    Women with intellectual disabilities have similar breast cancer rates as the general population, but lower rates of regular mammography and higher breast cancer mortality rates. Although prior qualitative work demonstrates that women with intellectual disabilities face unique, disability-specific barriers to mammography, the present authors lack standardized, validated instruments for measuring knowledge of breast cancer screening in this population. In addition, much research related to adults with intellectual disabilities focuses on family or carer perspectives, rather than involving women with intellectual disabilities, themselves. The present authors first pilot tested a general population instrument measuring breast cancer knowledge, and found that it did not perform adequately in women with intellectual disabilities. In response, the present authors developed the Mammography Preparedness Measure (MPM), a direct short interview tool to measure knowledge and preparedness in women with intellectual disabilities, themselves, rather than relying on caregiver or other reports, and using inclusive methodology. The present authors validated the MPM by assessing test-retest reliability. Average test-retest per cent agreement of 84%, ranging from 74 to 91% agreement per item, with an overall kappa of 0.59. The MPM appears to be a valid instrument appropriate for measuring mammography preparedness in women with intellectual disabilities. The success of this innovative tool suggests that direct, rather than informant-directed tools can be developed to measure health knowledge and cancer screening readiness in adults with intellectual disabilities, an important measure in studying and reducing disparities. © 2014 John Wiley & Sons Ltd.

  9. Decision making and counseling around mammography screening for women aged 80 or older.

    PubMed

    Schonberg, Mara A; Ramanan, Radhika A; McCarthy, Ellen P; Marcantonio, Edward R

    2006-09-01

    Despite uncertain benefit, many women over age 80 (oldest-old) receive screening mammography. To explore decision-making and physician counseling of oldest-old women around mammography screening. Qualitative research using in-depth semi-structured interviews. Twenty-three women aged 80 or older who received care at a large academic primary care practice (13 had undergone mammography screening in the past 2 years) and 16 physicians at the same center. We asked patients and physicians to describe factors influencing mammography screening decisions of oldest-old women. We asked physicians to describe their counseling about screening to the oldest-old. Patients and/or physicians identified the importance of physician influence, patient preferences, system factors, and social influences on screening decisions. Although physicians felt that patient's health affected screening decisions, few patients felt that health mattered. Three types of elderly patients were identified: (1) women enthusiastic about screening mammography; (2) women opposed to screening mammography; and (3) women without a preference who followed their physician's recommendation. However, physician counseling about mammography screening to elderly women varies; some individualize discussions; others encourage screening; few discourage screening. Physicians report that discussions about stopping screening can be uncomfortable and time consuming. Physicians suggest that more data could facilitate these discussions. Some oldest-old women have strong opinions about screening mammography while others are influenced by physicians. Discussions about stopping screening are challenging for physicians. More data about the benefits and risks of mammography screening for women aged 80 or older could inform patients and improve provider counseling to lead to more rational use of mammography.

  10. Effects of digital mammography uptake on downstream breast-related care among older women.

    PubMed

    Hubbard, Rebecca A; Zhu, Weiwei; Onega, Tracy L; Fishman, Paul; Henderson, Louise M; Tosteson, Anna N A; Buist, Diana S M

    2012-12-01

    Digital mammography is the dominant modality for breast cancer screening in the United States. No previous studies have investigated as to how introducing digital mammography affects downstream breast-related care. Compare breast-related health care use after a screening mammogram before and after introduction of digital mammography. Longitudinal study of screening mammograms from 14 radiology facilities contributing data to the Breast Cancer Surveillance Consortium performed 1 year before and 4 years after each facility introduced digital mammography, along with linked Medicare claims. We included 30,211 mammograms for women aged 66 years and older without breast cancer. Rates of false-positive recall and short-interval follow-up were based on radiologists' assessments and recommendations; rates of follow-up mammography, ultrasound, and breast biopsy use were based on Medicare claims. False-positive recall rates increased after the introduction of digital mammography. Follow-up mammography use was significantly higher across all 4 years after a facility began using digital mammography compared with the year before [year 1 odds ratio (OR) = 1.7, 95% confidence interval (CI), 1.4-2.1]. Among women with false-positive mammography results, use of ultrasound decreased significantly in the second through fourth years after digital mammography began (year 2 OR = 0.4, 95% CI, 0.3-0.6). Introduction of a new technology led to changes in health care use that persisted for at least 4 years. Comparative effectiveness research on new technologies should consider not only diagnostic performance but also downstream utilization attributable to this apparent learning curve.

  11. Update on new technologies in digital mammography

    PubMed Central

    Patterson, Stephanie K; Roubidoux, Marilyn A

    2014-01-01

    Despite controversy regarding mammography’s efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. PMID:25152634

  12. Lack of nationwide Danish guidelines on mammography before non-oncological breast surgery.

    PubMed

    Foged, Thomas; Sørensen, Jens Ahm; Søe, Katrine Lydolph; Bille, Camilla

    2015-05-01

    Non-oncological breast surgery like breast reduction and mastopexy are often performed in younger patients, i.e. in women who have not yet had mammography. Breast cancer is, however, a very frequent disease that is increasingly prevalent in women below 50 years of age. Occult breast cancer may not be recognised before breast surgery, which may result in several disadvantages for the women. Therefore, detecting a breast cancer before a woman undergoes non-oncological breast surgery is of paramount importance. All public plastic surgery and breast surgery departments and all private clinics or hospitals providing plastic surgery were asked two questions: 1) When do you recommend a mammography prior to non-oncological breast surgery? 2) How old must a mammogram be before it needs to be repeated? Answers were received from all plastic surgery and breast surgery departments, and all but three of the private clinics and hospitals. Overall, information was obtained from 95.5% of the respondents (n = 63). Currently, there are no Danish guidelines on mammography before non-oncological breast surgery. A national guideline could recommend a preoperative mammogram from the age of 40 years stipulating that the mammogram should have been made within the past 12 months; however, the final recommendation should be prepared by a multidisciplinary working group counting experts from plastic surgery, breast surgery, pathology and radiology. not relevant. not relevant.

  13. Does telephone scheduling assistance increase mammography screening adherence?

    PubMed

    Payton, Colleen A; Sarfaty, Mona; Beckett, Shirley; Campos, Carmen; Hilbert, Kathleen

    2015-11-01

    The 2 objectives were: 1) describe the use of a patient navigation process utilized to promote adherence to mammography screening within a primary care practice, and 2) determine the result of the navigation process and estimate the time required to increase mammography screening with this approach in a commercially insured patient population enrolled in a health maintenance organization. An evaluation of a nonrandomized practice improvement intervention. Women eligible for mammography (n = 298) who did not respond to 2 reminder letters were contacted via telephone by a navigator who offered scheduling assistance for mammography screening. The patient navigator scheduled appointments, documented the number of calls, and confirmed completed mammograms in the electronic health record, as well as estimated the time for calls and chart review. Of the 188 participants reached by phone, 112 (59%) scheduled appointments using the patient navigator, 35 (19%) scheduled their own appointments independently prior to the call, and 41 (22%) declined. As a result of the telephone intervention, 78 of the 188 women reached (41%) received a mammogram; also, all 35 women who had independently scheduled a mammogram received one. Chart documentation confirmed that 113 (38%) of the cohort of 298 women completed a mammogram. The estimated time burden for the entire project was 55 hours and 33 minutes, including calling patients, scheduling appointments, and chart review. A patient navigator can increase mammography adherence in a previously nonadherent population by making the screening appointment while the patient is on the phone.

  14. At what age should screening mammography be recommended for Asian women?

    PubMed

    Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi

    2015-07-01

    Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40-49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. Time for a re-evaluation of mammography in the young? Results of an audit of mammography in women younger than 40 in a resource restricted environment.

    PubMed

    Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin

    2011-08-01

    Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.

  16. Factors influencing elderly women's mammography screening decisions: implications for counseling.

    PubMed

    Schonberg, Mara A; McCarthy, Ellen P; York, Meghan; Davis, Roger B; Marcantonio, Edward R

    2007-11-16

    Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65-79. Telephone surveys of 107 women aged 80+ and 93 women aged 65-79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate). The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3%) had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65-79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65-79). While a doctor's recommendation is the most important factor influencing elderly women's mammography screening decisions, habit and reassurance

  17. X-ray light valve (XLV): a novel detectors' technology for digital mammography

    NASA Astrophysics Data System (ADS)

    Marcovici, Sorin; Sukhovatkin, Vlad; Oakham, Peter

    2014-03-01

    A novel method, based on X-ray Light Valve (XLV) technology, is proposed for making good image quality yet inexpensive flat panel detectors for digital mammography. The digital mammography markets, particularly in the developing countries, demand quality machines at substantially lower prices than the ones available today. Continuous pressure is applied on x-ray detectors' manufacturers to reduce the flat panel detectors' prices. XLV presents a unique opportunity to achieve the needed price - performance characteristics for direct conversion, x-ray detectors. The XLV based detectors combine the proven, superior, spatial resolution of a-Se with the simplicity and low cost of liquid crystals and optical scanning. The x-ray quanta absorbed by a 200 μm a-Se produce electron - hole pairs that move under an electric field to the top and bottom of a-Se layer. This 2D charge distribution creates at the interface with the liquid crystals a continuous (analog) charge image corresponding to the impinging radiation's information. Under the influence of local electrical charges next to them, the liquid crystals twist proportionally to the charges and vary their light reflectivity. A scanning light source illuminates the liquid crystals while an associated, pixilated photo-detector, having a 42 μm pixel size, captures the light reflected by the liquid crystals and converts it in16 bit words that are transmitted to the machine for image processing and display. The paper will describe a novel XLV, 25 cm x 30 cm, flat panel detector structure and its underlying physics as well as its preliminary performance measured on several engineering prototypes. In particular, the paper will present the results of measuring XLV detectors' DQE, MTF, dynamic range, low contrast resolution and dynamic behavior. Finally, the paper will introduce the new, low cost, XLV detector based, digital mammography machine under development at XLV Diagnostics Inc.

  18. Rayleigh imaging in spectral mammography

    NASA Astrophysics Data System (ADS)

    Berggren, Karl; Danielsson, Mats; Fredenberg, Erik

    2016-03-01

    Spectral imaging is the acquisition of multiple images of an object at different energy spectra. In mammography, dual-energy imaging (spectral imaging with two energy levels) has been investigated for several applications, in particular material decomposition, which allows for quantitative analysis of breast composition and quantitative contrast-enhanced imaging. Material decomposition with dual-energy imaging is based on the assumption that there are two dominant photon interaction effects that determine linear attenuation: the photoelectric effect and Compton scattering. This assumption limits the number of basis materials, i.e. the number of materials that are possible to differentiate between, to two. However, Rayleigh scattering may account for more than 10% of the linear attenuation in the mammography energy range. In this work, we show that a modified version of a scanning multi-slit spectral photon-counting mammography system is able to acquire three images at different spectra and can be used for triple-energy imaging. We further show that triple-energy imaging in combination with the efficient scatter rejection of the system enables measurement of Rayleigh scattering, which adds an additional energy dependency to the linear attenuation and enables material decomposition with three basis materials. Three available basis materials have the potential to improve virtually all applications of spectral imaging.

  19. Digital mammography, cancer screening: Factors important for image compression

    NASA Technical Reports Server (NTRS)

    Clarke, Laurence P.; Blaine, G. James; Doi, Kunio; Yaffe, Martin J.; Shtern, Faina; Brown, G. Stephen; Winfield, Daniel L.; Kallergi, Maria

    1993-01-01

    The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

  20. Dual-energy contrast-enhanced spectral mammography (CESM).

    PubMed

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  1. NATIONAL WATER-QUALITY ASSESSMENT (NAWQA) PROGRAM

    EPA Science Inventory

    The National Water-Quality Assessment (NAWQA) Program is designed to describe the status and trends in the quality of the Nations ground- and surface-water resources and to provide a sound understanding of the natural and human factors that affect the quality of these resources. ...

  2. A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kharrati, Hedi

    2005-05-01

    In this study, a new approach has been introduced for derivation of the effective dose from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to the effective dose for the mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium, National Institute of Standards and Technology, and International Atomic Energy Agency laboratories. The results show that, in all cases, the effective dose in mammography energy range is less than 25% of the incident air kerma for the primary and the scatter radiations andmore » does not exceed 75% for the leakage radiation.« less

  3. Community Partnerships, Food Pantries, and an Evidence-Based Intervention to Increase Mammography among Rural Women

    ERIC Educational Resources Information Center

    Bencivenga, Marcyann; DeRubis, Susan; Leach, Patricia; Lotito, Lisa; Shoemaker, Charles; Lengerich, Eugene J.

    2008-01-01

    Context: Multiple national agencies and organizations recommend that women age 40 years and older have an annual screening mammogram. Women who are poor, less educated, lack a usual source of care, and reside in rural Appalachia are less likely to have had a recent mammogram. Purpose: To increase use of mammography among a rural Appalachian…

  4. [Advances in research on automatic exposure control of mammography system].

    PubMed

    Wang, Guoyi; Ye, Chengfu; Wu, Haiming; Wang, Tainfu; Zhang, Hong

    2014-12-01

    Mammography imaging is one of the most demanding imaging modalities from the point of view of the bal- ance between image quality (the visibility of small size and/or low contrast structures) and dose (screening of many asymptomatic people). Therefore, since the introduction of the first dedicated mammographic units, many efforts have been directed to seek the best possible image quality while minimizing patient dose. The performance of auto- matic exposure control (AEC) is the manifestation of this demand. The theory of AEC includes exposure detection and optimization and also involves some accomplished methodology. This review presents the development and present situa- tion of spectrum optimization, detector evolution, and the way how to accomplish and evaluate AEC methods.

  5. Promoting mammography screening among Chinese American women using a message-framing intervention.

    PubMed

    Sun, Yiyuan; Sarma, Elizabeth A; Moyer, Anne; Messina, Catherine R

    2015-07-01

    This study examined the role of women's perceptions about the relative pros versus cons (decisional balance) of mammography in moderating Chinese American women's responses to gain- and loss-framed messages that promote mammography. One hundred and forty-three Chinese American women who were currently nonadherent to guidelines for receiving annual screening mammograms were randomly assigned to read either a gain- or loss-framed culturally appropriate print brochure about mammography screening. Mammography screening was self-reported at a 2-month follow-up. Although there was not a main effect for message frame, the hypothesized interaction between message frame and decisional balance was significant, indicating that women who received a framed message that matched their decisional balance were significantly more likely to have obtained a mammogram by the follow-up than women who received a mismatched message. Results suggest that decisional balance, and more generally, perceptions about mammography, may be an important moderator of framing effects for mammography among Chinese American women. The match between message frame and decisional balance should be considered when attempting to encourage Chinese American women to receive mammography screening, as a match between the two may be most persuasive. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Determinants of the number of mammography units in 31 countries with significant mammography screening

    PubMed Central

    Autier, P; Ouakrim, D A

    2008-01-01

    In the 2000s, most of the female population of industrialised countries had access to mammography breast cancer screening, but with variable modalities among the countries. We assessed the number of mammography units (MUs) in 31 European, North American and Asian countries where significant mammography activity has existed for over 10 years, collecting data on the number of such units and of radiologists by contacting institutions in each country likely to provide the relevant information. Around 2004, there were 32 324 MU in 31 countries, the number per million women ranging from less than 25 in Turkey, Denmark, the Netherlands, the United Kingdom, Norway, Poland and Hungary to more than 80 in Cyprus, Italy, France, the United States and Austria. In a multivariate analysis, the number of MUs was positively associated with the number of radiologists (P=0.0081), the number of women (P=0.0023) and somewhat with the country surface area (P=0.077). There is considerable variation in the density of MU across countries and the number of MUs in service are often well above what would be necessary according to local screening recommendations. High number of MUs in some countries may have undesirable consequences, such as unnecessarily high screening frequency and decreased age at which screening is started. PMID:18781176

  7. Magnetic resonance mammography in comparison with mammography in the discovery of multifocal, multicentric and bilateral lesions of breast cancer.

    PubMed

    Bakhtavar, Khadijeh; Saran, Maryam; Behzadifar, Masoud; Farsi, Maryam

    2017-08-01

    Breast cancer is one of the health system problems and important diseases that is rising in developing and advanced countries. This study aimed to determine the difference of Magnetic Resonance Mammography (MRM) findings versus mammography in detecting multifocal, multi-centric and malignant bilateral lesions in patients with known breast cancer in Tehran. This cross-sectional study was conducted in Iran and Tehran among breast cancer patients between January 2015 and February 2016. Patients were included in the study prior to surgery, at the request of a surgeon with the aim of detecting multifocal, multi-centric and bilateral lesions. Demographic information was also collected from patients. The results for quantitative variables were expressed as mean and standard deviations, and for qualitative variables, were expressed as relative and absolute frequency. Chi-square test was used to compare the two methods. SPSS Ver.24 (IBM) software was used to analyze the data. Thirty-nine patients were enrolled in the study. The mean age of patients in this study was 48.46±6.836. In mammography, 13 (33.3%) had Composition C and 26 (66.7%) had Composition D according to the type of Composition. In total, 25 patients (89.3%) had one lesion and 3 patients (10.7%) had more than two lesions. In MRM, all lesions observed were mass (54 masses). The number of lesions found in MRM was 27 patients with one lesion (58.9%), 6 patients with two lesions (20.5%) and 5 patients with three lesions (20.6%). MRM detected more lesions compared to mammography (p<0.0001). The value of Chi-square test with a degree of freedom and error level of 0.05 was 3.71 and p<0.0001 that showed a significant relationship between the number of MRM findings in comparison with mammography. The results of our study showed that two or more lesions and bilateral lesions in MRM were more than mammography in women with B Breast Composition C, D; the findings showed that MRM has a better ability to detect breast

  8. Cost-effectiveness of annual versus biennial screening mammography for women with high mammographic breast density.

    PubMed

    Pataky, Reka; Ismail, Zahra; Coldman, Andrew J; Elwood, Mark; Gelmon, Karen; Hedden, Lindsay; Hislop, Greg; Kan, Lisa; McCoy, Bonnie; Olivotto, Ivo A; Peacock, Stuart

    2014-12-01

    The sensitivity of screening mammography is much lower among women who have dense breast tissue, compared with women who have largely fatty breasts, and they are also at much higher risk of developing the disease. Increasing mammography screening frequency from biennially to annually has been suggested as a policy option to address the elevated risk in this population. The purpose of this study was to assess the cost-effectiveness of annual versus biennial screening mammography among women aged 50-79 with dense breast tissue. A Markov model was constructed based on screening, diagnostic, and treatment pathways for the population-based screening and cancer care programme in British Columbia, Canada. Model probabilities and screening costs were calculated from screening programme data. Costs for breast cancer treatment were calculated from treatment data, and utility values were obtained from the literature. Incremental cost-effectiveness was expressed as cost per quality adjusted life year (QALY), and probabilistic sensitivity analysis was conducted. Compared with biennial screening, annual screening generated an additional 0.0014 QALYs (95% CI: -0.0480-0.0359) at a cost of $819 ($ = Canadian dollars) per patient (95% CI: 506-1185), resulting in an incremental cost effectiveness ratio of $565,912/QALY. Annual screening had a 37.5% probability of being cost-effective at a willingness-to-pay threshold of $100,000/QALY. There is considerable uncertainty about the incremental cost-effectiveness of annual mammography. Further research on the comparative effectiveness of screening strategies for women with high mammographic breast density is warranted, particularly as digital mammography and density measurement become more widespread, before cost-effectiveness can be reevaluated. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Self-Report Versus Medical Record for Mammography Screening Among Minority Women.

    PubMed

    Nandy, Karabi; Menon, Usha; Szalacha, Laura A; Park, HanJong; Lee, Jongwon; Lee, Eunice E

    2016-12-01

    Self-report is the most common means of obtaining mammography screening data. The purpose of this study was to assess the accuracy of minority women's self-reported mammography by comparing their self-reported dates of mammograms with those in their medical records from a community-based randomized control trial. We found that out of 192 women, 116 signed the Health Information Portability and Accountability Act form and, among these, 97 had medical records that could be verified (97 / 116 = 83.6%). Ninety-two records matched where both sources confirmed a mammogram; 48 of 92 (52.2%) matched perfectly on self-reported date of mammogram. Complexities in the verification process warrant caution when verifying self-reported mammography screening in minority populations. In spite of some limitations, our findings support the usage of self-reported data on mammography as a validated tool for other researchers investigating mammography screening among minority women who continue to have low screening rates. © The Author(s) 2016.

  10. Cultural views, language ability, and mammography use in Chinese American women.

    PubMed

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S

    2009-12-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women's ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors' results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population.

  11. Cultural Views, Language Ability, and Mammography Use in Chinese American Women

    PubMed Central

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S.

    2013-01-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women’s ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors’ results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population. PMID:19233947

  12. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography.

    PubMed

    Treiber, O; Wanninger, F; Führ, H; Panzer, W; Regulla, D; Winkler, G

    2003-02-21

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing. a dose reduction by 25% has no serious influence on the detection results. whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  13. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography

    NASA Astrophysics Data System (ADS)

    Treiber, O.; Wanninger, F.; Führ, H.; Panzer, W.; Regulla, D.; Winkler, G.

    2003-02-01

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  14. Patterns and determinants of mammography screening in Lebanese women.

    PubMed

    Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M

    2017-03-01

    The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  15. Changing patterns of microcalcification on screening mammography for prediction of breast cancer.

    PubMed

    Kim, Kwan Il; Lee, Kyung Hee; Kim, Tae Ryung; Chun, Yong Soon; Lee, Tae Hoon; Choi, Hye Young; Park, Heung Kyu

    2016-05-01

    The presence of microcalcification on mammography is one of the earliest signs in breast cancer detection. However, it is difficult to distinguish malignant calcifications from benign calcifications. The aim of this study is to evaluate correlation between changing patterns of microcalcification on screening mammography and malignant breast lesions. Medical records and diagnostic images of 67 women who had previously undergone at least two digital mammograms at least 6 months apart and underwent mammography-guided needle localization and surgical excision between 2011 and 2013 were retrospectively reviewed and analyzed. Breast cancer was detected in the surgical specimens of 20 patients (29.9 %). Annual change of extent of microcalcification on mammography showed statistically significant correlation with pathologic outcome (P = 0.023). The changing pattern of new appearance or increased extent of microcalcification on mammography had positive predictive value of 54.8 % for breast cancer, and it was a statistically significant predictor for breast cancer (P = 0.012). Shape or number change of microcalcification without increased extent had less accurate predictive value for breast cancer, particularly in women younger than 50 years (P < 0.001). This study showed that the pattern of increased extent of microcalcification on screening mammography was a significant predictor for breast cancer. We suggest that mammography-guided needle localization and surgical excision should be considered when increased extent of microcalcification is observed on screening mammography and closed follow-up without pathologic confirmation can be permitted if absence of extension of microcalcification was confirmed in women younger than 50 years.

  16. REPEAT MAMMOGRAPHY SCREENING AMONG UNMARRIED WOMEN WITH AND WITHOUT A DISABILITY

    PubMed Central

    Clark, Melissa A.; Rogers, Michelle L.; Wen, Xiaozhong; Wilcox, Victoria; McCarthy-Barnett, Kate; Panarace, Jeanne; Manning, Carol; Allen, Susan; Rakowski, William

    2009-01-01

    Objectives Unmarried women with disabilities may be a particularly vulnerable group for underutilization of repeat mammography screening. Our goal was to compare the breast cancer screening experiences of unmarried women with disabilities (WWD) versus women with no disabilities (WND), and determine whether these experiences are associated with adherence to repeat screening. Methods We conducted a matched cohort study of 93 WWD and 93 WND to compare mammography experiences by disability status, examine rates of repeat mammography by disability status, and identify factors that are associated with repeat mammography. Results WWD were less likely to be on-schedule than WND in univariable (54.8% vs. 71.0%; relative risk = 0.77, 95% CL = 0.61, 0.97), but not multivariable, analyses. In multivariable analyses, there was a significant interaction between disability status and positive experiences as the reasons for returning to the same mammography facility. Among WND, repeat screening ranged from 59% to 86%, depending on the number of positive experiences endorsed (range=1–5). In contrast, among WWD, screening rates were only 37% among those who did not report any positive experiences and increased to a maximum of 60% regardless of whether women endorsed one to four or all five positive experiences. Severity and type of disability were not associated with repeat screening. Conclusions WWD may be less likely than WND to remain on-schedule for mammography. WWD who do not report any positive experiences as reasons for returning to a mammography facility may be at particularly high risk of underutilization of screening. PMID:19775912

  17. [Mammography screening of breast cancer in Tunisia. Results of first experience].

    PubMed

    Kribi, Lilia; Sellami, Dorra; el Amri, Aïda; Mnif, Nejla; Ellouze, Thouraya; Chebbi, Ali; Ben Romdhane, Khaled; Hamza, Radhi

    2003-01-01

    This article reports the results of a mammography screening program of breast cancer, realized in the department of Radiology, Charles Nicolle hospital. A free screening mammography with two incidences was offered to women aged from 40 to 70 years old. 2200 mammographies were realized from May 1995 till July 1997. Women having a positive test benefited of a diagnostic explorations in the same unity. The positive test rate was 24%. Predictive positive value was 31%. This program allowed to detect 10 subclinical cancers, corresponding to a rate of detection of 4.5 cancers for 1000 women. This program is a first experience which demonstrated the feasibility of the mammography screening to wide scale and allowed the medical and paramedical team to acquire an experience.

  18. Complete internal audit of a mammography service in a reference institution for breast imaging.

    PubMed

    Badan, Gustavo Machado; Roveda Júnior, Décio; Ferreira, Carlos Alberto Pecci; de Noronha Junior, Ozeas Alves

    2014-01-01

    Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS(®), in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.

  19. Study of signal-to-noise ratio in digital mammography

    NASA Astrophysics Data System (ADS)

    Kato, Yuri; Fujita, Naotoshi; Kodera, Yoshie

    2009-02-01

    Mammography techniques have recently advanced from those using analog systems (the screen-film system) to those using digital systems; for example, computed radiography (CR) and flat-panel detectors (FPDs) are nowadays used in mammography. Further, phase contrast mammography (PCM)-a digital technique by which images with a magnification of 1.75× can be obtained-is now available in the market. We studied the effect of the air gap in PCM and evaluated the effectiveness of an antiscatter x-ray grid in conventional mammography (CM) by measuring the scatter fraction ratio (SFR) and relative signal-to-noise ratio (rSNR) and comparing them between PCM and the digital CM. The results indicated that the SFRs for the CM images obtained with a grid were the lowest and that these ratios were almost the same as those for the PCM images. In contrast, the rSNRs for the PCM images were the highest, which means that the scattering of x-rays was sufficiently reduced by the air gap without the loss of primary x-rays.

  20. Feasibility study for positron emission mammography.

    PubMed

    Thompson, C J; Murthy, K; Weinberg, I N; Mako, F

    1994-04-01

    A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.

  1. Simulation of digital mammography images

    NASA Astrophysics Data System (ADS)

    Workman, Adam

    2005-04-01

    A number of different technologies are available for digital mammography. However, it is not clear how differences in the physical performance aspects of the different imaging technologies affect clinical performance. Randomised controlled trials provide a means of gaining information on clinical performance however do not provide direct comparison of the different digital imaging technologies. This work describes a method of simulating the performance of different digital mammography systems. The method involves modifying the imaging performance parameters of images from a small field of view (SFDM), high resolution digital imaging system used for spot imaging. Under normal operating conditions this system produces images with higher signal-to-noise ratio (SNR) over a wide spatial frequency range than current full field digital mammography (FFDM) systems. The SFDM images can be 'degraded" by computer processing to simulate the characteristics of a FFDM system. Initial work characterised the physical performance (MTF, NPS) of the SFDM detector and developed a model and method for simulating signal transfer and noise properties of a FFDM system. It was found that the SNR properties of the simulated FFDM images were very similar to those measured from an actual FFDM system verifying the methodology used. The application of this technique to clinical images from the small field system will allow the clinical performance of different FFDM systems to be simulated and directly compared using the same clinical image datasets.

  2. Moving beyond the Typologies of Managed Care: The Example of Health Plan Predictors of Screening Mammography

    PubMed Central

    Tye, Sherilyn; Phillips, Kathryn A; Liang, Su-Ying; Haas, Jennifer S

    2004-01-01

    Objectives To develop a framework of factors to characterize health plans, to identify how plan characteristics were measured in a national survey, and to apply our findings to an analysis of the predictors of screening mammography. Data Source The primary data were from the 1996 Medical Expenditure Panel Survey. Study Design Women ages 40+, with private insurance, and no history of breast cancer were included in the study (N=2,909). We used multivariate logistic regression to estimate mammography utilization in the past two years relative to health plan and demographic factors. Health plan measures included whether there is a defined provider network, whether coverage is restricted to a network, use of gatekeepers, level of cost containment, copayment and deductible amounts, coinsurance rate, and breadth of benefit coverage. Principal Findings We found no significant difference in reported mammography utilization using a dichotomous comparison of individuals enrolled in managed care versus indemnity plans. However, women in health plans with a defined provider network were more likely to report having received a mammogram in the past two years than those without networks (adjusted OR=1.21, 95 percent CI=1.07–1.36), and women in gatekeeper plans were more likely to report receiving mammography than those without gatekeepers (adjusted OR=1.18, 95 percent CI=1.03–1.36). Restricted out-of-network coverage, use of cost containment, enrollee cost sharing, and breadth of benefit coverage did not appear to affect mammography use. Conclusions It is important to examine the effect of individual health plan components on the utilization of health care, rather than use the traditional broader categorizations of managed versus nonmanaged care or simple health plan typologies. PMID:14965083

  3. As mammography use increases, are some providers omitting clinical breast examination?

    PubMed

    Burns, R B; Freund, K M; Ash, A S; Shwartz, M; Antab, L; Hall, R

    1996-04-08

    To explore use of clinical breast examination (CBE) among women receiving mammography. A retrospective cohort analysis of 100 women aged 50 years or older with at least one bilateral mammogram. Chart review documented demographic information, severity of illness, and performance of CBE (from 1 year prior to 18 months after the mammogram). The mean age of the 100 women was 63 years. They were predominantly unmarried (60%), nonwhite (58%), and not currently employed (57%). Three quarters (76%) had mammography and CBE (comprehensive screening), while the remaining 24% had mammography only. Sociodemographic factors did not differ for women with and without comprehensive screening (P>.1). However, patients of female providers were more likely to receive comprehensive screening than patients of male providers. Specifically, 95% of women seen by female attending physicians or fellows had comprehensive screening vs 67% for male attending physicians or fellows and 61% for residents (P=.008). Mammography may be replacing CBE especially among patients of male providers. Interventions targeted to these providers could help improve the use of CBE and mammography.

  4. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme.

    PubMed

    Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E

    2014-07-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.

  5. Beyond the mammography debate: a moderate perspective.

    PubMed

    Kaniklidis, C

    2015-06-01

    After some decades of contention, one can almost despair and conclude that (paraphrasing) "the mammography debate you will have with you always." Against that sentiment, in this review I argue, after reflecting on some of the major themes of this long-standing debate, that we must begin to move beyond the narrow borders of claim and counterclaim to seek consensus on what the balance of methodologically sound and critically appraised evidence demonstrates, and also to find overlooked underlying convergences; after acknowledging the reality of some residual and non-trivial harms from mammography, to promote effective strategies for harm mitigation; and to encourage deployment of new screening modalities that will render many of the issues and concerns in the debate obsolete. To these ends, I provide a sketch of what this looking forward and beyond the current debate might look like, leveraging advantages from abbreviated breast magnetic resonance imaging technologies (such as the ultrafast and twist protocols) and from digital breast tomosynthesis-also known as three-dimensional mammography. I also locate the debate within the broader context of mammography in the real world as it plays out not for the disputants, but for the stakeholders themselves: the screening-eligible patients and the physicians in the front lines who are charged with enabling both the acts of screening and the facts of screening at their maximally objective and patient-accessible levels to facilitate informed decisions.

  6. Beyond the mammography debate: a moderate perspective

    PubMed Central

    Kaniklidis, C

    2015-01-01

    After some decades of contention, one can almost despair and conclude that (paraphrasing) “the mammography debate you will have with you always.” Against that sentiment, in this review I argue, after reflecting on some of the major themes of this long-standing debate, that we must begin to move beyond the narrow borders of claim and counterclaim to seek consensus on what the balance of methodologically sound and critically appraised evidence demonstrates, and also to find overlooked underlying convergences; after acknowledging the reality of some residual and non-trivial harms from mammography, to promote effective strategies for harm mitigation; and to encourage deployment of new screening modalities that will render many of the issues and concerns in the debate obsolete. To these ends, I provide a sketch of what this looking forward and beyond the current debate might look like, leveraging advantages from abbreviated breast magnetic resonance imaging technologies (such as the ultrafast and twist protocols) and from digital breast tomosynthesis—also known as three-dimensional mammography. I also locate the debate within the broader context of mammography in the real world as it plays out not for the disputants, but for the stakeholders themselves: the screening-eligible patients and the physicians in the front lines who are charged with enabling both the acts of screening and the facts of screening at their maximally objective and patient-accessible levels to facilitate informed decisions. PMID:26089721

  7. Validation of electrical impedance tomography qualitative and quantitative values and comparison of the numeric pain distress score against mammography.

    PubMed

    Juliana, Norsham; Shahar, Suzana; Chelliah, Kanaga Kumari; Ghazali, Ahmad Rohi; Osman, Fazilah; Sahar, Mohd Azmani

    2014-01-01

    Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of 1.51±0.75 whereas mammography scored 4.15±0.87 (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.

  8. Screening mammography--early detection or over-diagnosis? Contribution from Australian data.

    PubMed

    Bell, R J

    2014-12-01

    The aim of this review was to examine the benefits and harms of organized screening mammography, with particular reference to data from Australia. Published literature was examined relating to the impact of screening mammography on breast cancer-specific mortality, the trends in use of adjuvant treatments for breast cancer, the effectiveness of adjuvant treatment in terms of breast cancer-specific mortality, the impact of breast cancer treatment on non-breast cancer mortality and the magnitude of the issue of over-diagnosis. Most of the recent reduction in breast cancer-specific mortality is explained by use of adjuvant therapy rather than screening mammography. The impact of screening mammography in countries where women present with early disease and have access to adjuvant treatment is modest. There is a wide range of estimates for the magnitude of over-diagnosis. All-cause mortality (rather than breast cancer-specific mortality) should be used when assessing the impact of mammographic screening as otherwise the harm of breast cancer treatment in women who are over-diagnosed will be missed. The benefits and harms of screening mammography are finely balanced. The impact of screening mammography is at best neutral but may result in overall harm. Women should be informed of the issue of over-diagnosis. It is time to review whether organized mammographic screening programs should continue.

  9. Determination of the anxiety level of women who present for mammography.

    PubMed

    Bölükbaş, Nurgül; Erbil, Nülüfer; Kahraman, Azize Nuran

    2010-01-01

    This paper was to examine the role of anxiety in mammography screening. Breast cancer screening with mammography has been shown to be effective for preventing breast cancer death. However mammography screening can be harmful to women. One of the major problems is anxiety or lack of peace of mind in mammography screening. This study was conducted between November 3, 2007, and December 30, 2007, in Ordu Maternity and Childbirth Hospital. 93 women participated in the study. A 23-item questionnaire and the 20-item State Anxiety Inventory, developed by Spielberger et al. were completed by the participants. All numerical values were given as average ± standard deviation; p<0.05 was accepted for level of significance. The average age of the participants was 47.83 ± 7.50, the average age at marriage was 20.03 ± 4.18, the average birth number 2.91 ± 1.21, and the average age at menopause was 46.10 ± 4.70. The average anxiety level was found to be 46.20 ± 4.9. Significant differences (p<0.05) were found between education level, age at marriage, status of doing breast self examination, status of having a mammography for a breast-related complaint, and the number of mammograms done. It was determined that women who had mammography had a moderate level of anxiety.

  10. Effectiveness of a Mobile Mammography Program.

    PubMed

    Stanley, Elizabeth; Lewis, Madelene C; Irshad, Abid; Ackerman, Susan; Collins, Heather; Pavic, Dag; Leddy, Rebecca J

    2017-12-01

    Mobile mammography units have increasingly been used to address patient health care disparities; however, there are limited data comparing mobile units to stationary sites. This study aims to evaluate the characteristics of women who underwent mammography screening in a mobile unit versus those who underwent mammography screening at a cancer center. In this retrospective study, we analyzed all screening mammography examinations performed in a mobile unit in 2014 (n = 1433 examinations). For comparison, we randomized and reviewed an equivalent number of screening mammography examinations performed at our cancer center in 2014 (n = 1434 examinations). BI-RADS assessment, adherence to follow-up, biopsies performed, cancer detection rate, and sociodemographic variables were recorded. An independent-samples t test was conducted to identify potential differences in age between cancer center patients and mobile unit patients. Chi-square analyses were used to test for associations between location and factors such as health insurance, race, marital status, geographic area, adherence to screening guidelines, recall rate, adherence to follow-up, and cancer detection rates. Patients visiting our cancer center (mean = 57.74 years; SD = 10.55) were significantly older than those visiting the mobile unit (mean = 52.58 years; SD = 8.19; p < 0.001). There was a significant association between location and health insurance status (χ 2 = 610.92; p < 0.001) with more uninsured patients undergoing screening in the mobile van (cancer center = 3.70%, mobile unit = 38.73%). There was a significant association between screening location and patient race (χ 2 = 118.75, p < 0.001), with more white patients being screened at the cancer center (cancer center = 47.28%, mobile unit = 33.30%), more black patients being screened in the mobile van (cancer center = 49.30%, mobile unit = 54.15%), and more Hispanic patients being screened in the mobile van (cancer center = 1.05%, mobile unit = 6

  11. Obesity, Gynecological Factors, and Abnormal Mammography Follow-Up in Minority and Medically Underserved Women

    PubMed Central

    Wujcik, Debra; Lin, Jin-Mann S.; Grau, Ana; Wilson, Veronica; Champion, Victoria; Zheng, Wei; Egan, Kathleen M.

    2009-01-01

    Abstract Background The relationship between obesity and screening mammography adherence has been examined previously, yet few studies have investigated obesity as a potential mediator of timely follow-up of abnormal (Breast Imaging Reporting and Data System [BIRADS-0]) mammography results in minority and medically underserved patients. Methods We conducted a retrospective cohort study of 35 women who did not return for follow-up >6 months from index abnormal mammography and 41 who returned for follow-up ≤6 months in Nashville, Tennessee. Patients with a BIRADS-0 mammography event in 2003–2004 were identified by chart review. Breast cancer risk factors were collected by telephone interview. Multivariate logistic regression was performed on selected factors with return for diagnostic follow-up. Results Obesity and gynecological history were significant predictors of abnormal mammography resolution. A significantly higher frequency of obese women delayed return for mammography resolution compared with nonobese women (64.7% vs. 35.3%). A greater number of hysterectomized women returned for diagnostic follow-up compared with their counterparts without a hysterectomy (77.8% vs. 22.2%). Obese patients were more likely to delay follow-up >6 months (adjusted OR 4.09, p = 0.02). Conversely, hysterectomized women were significantly more likely to return for timely mammography follow-up ≤6 months (adjusted OR 7.95, p = 0.007). Conclusions Study results suggest that weight status and gynecological history influence patients' decisions to participate in mammography follow-up studies. Strategies are necessary to reduce weight-related barriers to mammography follow-up in the healthcare system including provider training related to mammography screening of obese women. PMID:19558307

  12. Mammography screening: A major issue in medicine.

    PubMed

    Autier, Philippe; Boniol, Mathieu

    2018-02-01

    Breast cancer mortality is declining in most high-income countries. The role of mammography screening in these declines is much debated. Screening impacts cancer mortality through decreasing the incidence of number of advanced cancers with poor prognosis, while therapies and patient management impact cancer mortality through decreasing the fatality of cancers. The effectiveness of cancer screening is the ability of a screening method to curb the incidence of advanced cancers in populations. Methods for evaluating cancer screening effectiveness are based on the monitoring of age-adjusted incidence rates of advanced cancers that should decrease after the introduction of screening. Likewise, cancer-specific mortality rates should decline more rapidly in areas with screening than in areas without or with lower levels of screening but where patient management is similar. These two criteria have provided evidence that screening for colorectal and cervical cancer contributes to decreasing the mortality associated with these two cancers. In contrast, screening for neuroblastoma in children was discontinued in the early 2000s because these two criteria were not met. In addition, overdiagnosis - i.e. the detection of non-progressing occult neuroblastoma that would not have been life-threatening during the subject's lifetime - is a major undesirable consequence of screening. Accumulating epidemiological data show that in populations where mammography screening has been widespread for a long time, there has been no or only a modest decline in the incidence of advanced cancers, including that of de novo metastatic (stage IV) cancers at diagnosis. Moreover, breast cancer mortality reductions are similar in areas with early introduction and high penetration of screening and in areas with late introduction and low penetration of screening. Overdiagnosis is commonplace, representing 20% or more of all breast cancers among women invited to screening and 30-50% of screen

  13. Trends in mammography utilization for breast cancer screening in a Middle-Eastern country: Lebanon 2005-2013.

    PubMed

    Haddad, Fady G; Kourie, Hampig Raphael; Adib, Salim M

    2015-12-01

    In Lebanon, annual national breast awareness campaigns were started in 2002 during the international breast month of October to promote the utilization of mammography for women aged ≥ 40. The impact of the campaigns has been assessed periodically since 2003. Results of 2003-2005 campaigns have been published previously. To measure the prevalence of two behavioral outcomes of interest: ever-use of mammography, and repeat mammography in the previous 12 months among ever-users. The prevalence was described by region and age group. The aim was to document the effectiveness of the program towards reaching a nationally defined goal of 80% screening coverage. The survey's sampling frame was developed incrementally, and since 2005 it has included women aged ≥ 40 from all areas of Lebanon. The sample size has also increased incrementally from 1200 in 2005 to 2400 in 2013. Results have been tabulated biannually and presented as historical trends with regional and demographic variations covering a 9-year period. In all six consecutive surveys presented here, the mean age of participating women was about 50 years. Year-by-year increases in utilization indicators were detected, with consistent differences in favor of the more urban areas in and around the capital city Beirut and its suburbs (Greater Beirut or GB). By 2013, ever-utilization had reached 43% (41-45) and recent mammography 20% (18-22) nationwide. Utilization was significantly more important in the age group 50-59 compared with the age group 40-49 or ≥ 60. While recent rates have increased nationwide, they have reached a plateau of about 25% in GB and are tending to the same level in other areas. While initial progress was slow, it has been accelerating in the last 4-5 years, indicating that the message is being accepted by a larger audience of targeted women at each iteration. However, concern remains that women between 40 and 50 and those >60 are not responding as well as desired to the screening message

  14. Consensus review of discordant findings maximizes cancer detection rate in double-reader screening mammography: Irish National Breast Screening Program experience.

    PubMed

    Shaw, Colette M; Flanagan, Fidema L; Fenlon, Helen M; McNicholas, Michelle M

    2009-02-01

    To assesses consensus review of discordant screening mammography findings in terms of its sensitivity, safety, and effect on overall performance in the first 6 years of operation of the Irish National Breast Screening Program (NBSP). Women who participated in the Irish NBSP gave written informed consent for use of their data for auditing purposes. Local ethics committee approval was obtained. The study population consisted of women who participated in the Irish NBSP and underwent initial screening mammography at one of the two screening centers serving the eastern part of Ireland between 2000 and 2005. Independent double reading of mammograms was performed. When the readers disagreed regarding referral, the case was reviewed by a consensus panel. Of the 128 569 screenings performed, 1335 (1%) were discussed by consensus. Of the 1335 cases discussed by consensus, 606 (45.39%) were recalled for further assessment. This resulted in an overall recall rate of 4.41%. In those recalled to assessment, 71 cases of malignant disease were diagnosed (ductal carcinoma in situ, n = 24; invasive cancer, n = 47). The remaining 729 patients were returned to biennial screening. Of these 729 patients, seven had false-negative findings that were identified in the subsequent screening round. Use of the highest reader recall method, in which a patient is recalled if her findings are deemed abnormal by either reader, could potentially increase the cancer detection rate by 0.6 per 1000 women screened but would increase the recall rate by 12.69% and the number of false-positive findings by 15.37%. The consensus panel identified 71 (7.33%) of 968 cancers diagnosed. Consensus review substantially reduced the number of cases recalled and was associated with a low false-negative rate.

  15. [Hierarchy structuring for mammography technique by interpretive structural modeling method].

    PubMed

    Kudo, Nozomi; Kurowarabi, Kunio; Terashita, Takayoshi; Nishimoto, Naoki; Ogasawara, Katsuhiko

    2009-10-20

    Participation in screening mammography is currently desired in Japan because of the increase in breast cancer morbidity. However, the pain and discomfort of mammography is recognized as a significant deterrent for women considering this examination. Thus quick procedures, sufficient experience, and advanced skills are required for radiologic technologists. The aim of this study was to make the point of imaging techniques explicit and to help understand the complicated procedure. We interviewed 3 technologists who were highly skilled in mammography, and 14 factors were retrieved by using brainstorming and the KJ method. We then applied Interpretive Structural Modeling (ISM) to the factors and developed a hierarchical concept structure. The result showed a six-layer hierarchy whose top node was explanation of the entire procedure on mammography. Male technologists were related to as a negative factor. Factors concerned with explanation were at the upper node. We gave attention to X-ray techniques and considerations. The findings will help beginners improve their skills.

  16. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    NASA Astrophysics Data System (ADS)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  17. MO-AB-207-04: ACR Update in Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berns, E.

    2015-06-15

    A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date asmore » the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.« less

  18. [Programs of early detection of breast cancer and access of mammography in Spain].

    PubMed

    Luengo, S; Azcona, B; Lázaro, P; Madero, R

    1997-05-24

    We studied availability to mammography among Spanish women aged 40 to 70 years, variation in use of the mammography by autonomous community, and the situation and importance of breast cancer screening programs among other factors, in the access to mammography. A cross-sectional population survey was conducted in 1994 in a sample of 3,218 women. A questionnaire was used to collect data on the variable access (receipt of at least one mammogram in the last 2 years) as well as different access-related variables. Information on breast cancer screening programs was collected by contacting the responsible institutions. We considered that a program had total coverage if it included all the municipalities in the province and partial if it did not include all municipalities. Twenty-eight percent of women had performed a mammogram. This proportion varied among autonomous communities (AACC) from 11.5 to 73.8%. Breast cancer screening programs existed in 8 AACC. The multivariant analysis revealed an association between access to mammography and the existence of a screening program, especially when the later had total coverage (OR = 7.64; 95% CI = 5.24-11.10). An association was also found between access to mammography and physician-related factors, place of residence and attitudes of women toward mammography. Less than one third of women aged 40-70 have performed a mammography in the last 2 years, and this proportion varies among AACC. Gynecologist visits and the existence of breast cancer screening programs are fundamental factors in the access to mammography in Spain.

  19. Cost-effectiveness of targeted versus tailored interventions to promote mammography screening among women military veterans in the United States.

    PubMed

    Lairson, David R; Chan, Wen; Chang, Yu-Chia; del Junco, Deborah J; Vernon, Sally W

    2011-05-01

    We conducted an economic evaluation of mammography promotion interventions in a population-based, nationally representative sample of 5500 women veterans. Women 52 years and older were randomly selected from the National Registry of Women Veterans and randomly assigned to a survey-only control group and two intervention groups that varied in the extent of personalization (tailored vs. targeted). Effectiveness measures were the prevalence of at least one self-reported post-intervention mammogram and two post-intervention mammograms 6-15 months apart. Incremental cost-effectiveness ratios (ICERs) were the incremental cost per additional person screened. Uncertainty was examined with sensitivity analysis and bootstrap simulation. The targeted intervention cost $25 per person compared to $52 per person for the tailored intervention. About 27% of the cost was incurred in identifying and recruiting the eligible population. The percent of women reporting at least one mammogram were .447 in the control group, .469 in the targeted group, and .460 in the tailored group. The ICER was $1116 comparing the targeted group to the control group (95% confidence interval (CI)=$493 to dominated). The tailored intervention was dominated (more costly and less effective) by the targeted intervention. Decision-makers should consider effectiveness evidence and the full recruitment and patient time costs associated with the implementation of screening interventions when making investments in mammography screening promotion programs. Identification and recruitment of eligible participants add substantial costs to outreach screening promotion interventions. Tailoring adds substantial cost to the targeted mammography promotion strategy without a commensurate increase in effectiveness. Although cost-effectiveness has been reported to be higher for some in-reach screening promotion interventions, a recent meta-analysis revealed significant heterogeneity in the effect sizes of published health

  20. National Water Quality Laboratory - A Profile

    USGS Publications Warehouse

    Raese, Jon W.

    2001-01-01

    The U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) is a full-service laboratory that specializes in environmental analytical chemistry. The NWQL's primary mission is to support USGS programs requiring environmental analyses that provide consistent methodology for national assessment and trends analysis. The NWQL provides the following: high-quality chemical data; consistent, published, state-of-the-art methodology; extremely low-detection levels; high-volume capability; biological unit for identifying benthic invertebrates; quality assurance for determining long-term water-quality trends; and a professional staff.

  1. Mammography Prevalence within 2 Two Years (Age 40+) - Small Area Estimates

    Cancer.gov

    For mammography, a woman 40 years of age or older must have reported having at least one mammography in her life. Furthermore, she should have had the most recent one within the last two years by the time of interview.

  2. Screening Mammography Utilization in Tennessee Women: The Association with Residence

    ERIC Educational Resources Information Center

    Brown, Kathleen C.; Fitzhugh, Eugene C.; Neutens, James J.; Klein, Diane A.

    2009-01-01

    Context: Approximately 70% of US women over age 40 report mammography screening within 2 years. However, rates are likely to vary by age, income, educational level, and residence. Purpose: To describe the prevalence of screening mammography and associated factors in women living in rural and urban areas of Tennessee. Methods: Using pooled data…

  3. The influence of social support relationships on mammography screening in African-American women.

    PubMed

    Fowler, Barbara Ann

    2007-07-01

    Evidence indicates that mammography screenings have increased in African-American women who are 50 years of age or older; however, they continue to experience later-stage discovery and poorer survival rates from breast cancer compared to White women. Although research has consistently found that social support relationships affects mammography screening in African-American women, little is known about the preventive health behaviors of individuals in these relationships that may be associated with mammography screening. This study examined that association and found that social support relationships, defined as blood-relatives and extended kinship networks, stressed personal responsibility and accountability for preventive health; therefore, supporting mammography screening. Of perhaps the greatest importance, the relationships emphasized positive strengths of African-American culture and invoked the necessity to confront prior negative experiences in health-care systems. These relationships also negated the fears or fatalistic beliefs about breast cancer that had been perpetuated by myths through informal communication and "deliberate silence" from significant others who had previously discouraged or de-emphasized the importance of mammography screening. Further research is needed to determine if the emphasis on cultural heritage was the only motivator that encouraged personal responsibility for mammography screening.

  4. Artificial neural networks in mammography interpretation and diagnostic decision making.

    PubMed

    Ayer, Turgay; Chen, Qiushi; Burnside, Elizabeth S

    2013-01-01

    Screening mammography is the most effective means for early detection of breast cancer. Although general rules for discriminating malignant and benign lesions exist, radiologists are unable to perfectly detect and classify all lesions as malignant and benign, for many reasons which include, but are not limited to, overlap of features that distinguish malignancy, difficulty in estimating disease risk, and variability in recommended management. When predictive variables are numerous and interact, ad hoc decision making strategies based on experience and memory may lead to systematic errors and variability in practice. The integration of computer models to help radiologists increase the accuracy of mammography examinations in diagnostic decision making has gained increasing attention in the last two decades. In this study, we provide an overview of one of the most commonly used models, artificial neural networks (ANNs), in mammography interpretation and diagnostic decision making and discuss important features in mammography interpretation. We conclude by discussing several common limitations of existing research on ANN-based detection and diagnostic models and provide possible future research directions.

  5. Characterization of scatter in digital mammography from physical measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leon, Stephanie M., E-mail: Stephanie.Leon@uth.tmc.edu; Wagner, Louis K.; Brateman, Libby F.

    2014-06-15

    Purpose: That scattered radiation negatively impacts the quality of medical radiographic imaging is well known. In mammography, even slight amounts of scatter reduce the high contrast required for subtle soft-tissue imaging. In current clinical mammography, image contrast is partially improved by use of an antiscatter grid. This form of scatter rejection comes with a sizeable dose penalty related to the concomitant elimination of valuable primary radiation. Digital mammography allows the use of image processing as a method of scatter correction that might avoid effects that negatively impact primary radiation, while potentially providing more contrast improvement than is currently possible withmore » a grid. For this approach to be feasible, a detailed characterization of the scatter is needed. Previous research has modeled scatter as a constant background that serves as a DC bias across the imaging surface. The goal of this study was to provide a more substantive data set for characterizing the spatially-variant features of scatter radiation at the image detector of modern mammography units. Methods: This data set was acquired from a model of the radiation beam as a matrix of very narrow rays or pencil beams. As each pencil beam penetrates tissue, the pencil widens in a predictable manner due to the production of scatter. The resultant spreading of the pencil beam at the detector surface can be characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were calculated from measurements obtained using the beam stop method. Two digital mammography units were utilized, and the SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and presence or absence of a grid. These values were then used to generate general equations allowing the SF and MRE to be calculated for any combination of the above parameters. Results: With a grid, the SF ranged from a minimum of about 0.05 to a maximum of about

  6. Value of mammography and breast ultrasound in male patients with nipple discharge.

    PubMed

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Evidence-based information on mammography screening in Austria--reality or more pie in the sky?

    PubMed

    Rásky, É; Groth, S

    2013-03-01

    Health literacy is gaining increasing importance in prevention and health care. This is the case for patients and for health-care professionals. Information and risk communication should comply with defined criteria and strengthen health literacy as they are a prerequisite for informed decision making. In this study, we analyse the content of the printed information material (brochures and pamphlets) on mammography screening for consumers that were distributed in Austria in 2011. The evaluation of the 11 brochures shows that the content does not comply with the prerequisites for informed decision making. Since the last study - published in 2004 - the situation has only slightly improved. The authors reemphasise the need for a targeted multimodal information campaign. This is particularly important as a systematic national mammography screening program in compliance with the guidelines of the European Commission will be introduced in Austria in 2013. © Georg Thieme Verlag KG Stuttgart · New York.

  8. First breast cancer mammography screening program in Mexico: initial results 2005-2006.

    PubMed

    Rodríguez-Cuevas, Sergio; Guisa-Hohenstein, Fernando; Labastida-Almendaro, Sonia

    2009-01-01

    Breast cancer is the most frequent malignant neoplasia worldwide. In emergent countries as Mexico, an increase has been shown in frequency and mortality, unfortunately, most cases in advanced loco-regional stages developed in young women. The success of breast screening in mortality reduction has been observed since 1995 in Western Europe and the United States, where as many as 40% mortality reduction has been achieved. Most countries guidelines recommends an annual or biannual mammography for all women >40 years of age. In 2005, FUCAM, a nonlucrative civil foundation in Mexico join with Mexico City government, initiated the first voluntary mammography screening program for women >40 years of age residing in Mexico City's Federal District. Mammographies were carried out with analogical mammographs in specially designed mobile units and were performed in the area of women's domiciles. This report includes data from the first 96,828 mammographies performed between March 2005 and December 2006. There were 1% of mammographies in Breast Imaging Reporting and Data System 0, 4, or 5 and 208 out of 949 women with abnormal mammographies (27.7%) had breast cancer, a rate of 2.1 per thousand, most of them in situ or stage I (29.4%) or stage II (42.2%) nevertheless 21% of those women with abnormal mammography did not present for further clinical and radiologic evaluation despite being personally notified at their home addresses. The breast cancer rate of Mexican women submitted to screening mammography is lower than in European or North American women. Family history of breast cancer, nulliparity, absence of breast feeding, and increasing age are factors that increase the risk of breast cancer. Most cancers were diagnosed in women's age below 60 years (68.5%) with a mean age of 53.55 corroborating previous data published. It is mandatory to sensitize and educate our population with regard to accepting to visit the Specialized Breast Centers.

  9. [Comparative study between film mammography and xeromammography; including specimen radiography].

    PubMed

    Maeda, M; Hayakawa, K; Okuno, Y; Torizuka, T; Mitsumori, M; Soga, T; Misaki, T; Dokou, S; Ito, K

    1990-10-01

    We retrospectively evaluated preoperative film- and xeromammography of 23 cases with breast cancers, and compared with postoperative specimen radiography to assess tumor delineation and microcalcification detectability. In tumor detection and margin delineation, film mammography was superior to xeromammography, and in microcalcification, film mammography was equal to xeromammography. These results had a effect on the diagnosis of breast cancers.

  10. Postmortem validation of breast density using dual-energy mammography

    PubMed Central

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer. PMID:25086548

  11. Postmortem validation of breast density using dual-energy mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decompositionmore » was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.« less

  12. Turkish translation and adaptation of Champion's Health Belief Model Scales for breast cancer mammography screening.

    PubMed

    Yilmaz, Meryem; Sayin, Yazile Yazici

    2014-07-01

    To examine the translation and adaptation process from English to Turkish and the validity and reliability of the Champion's Health Belief Model Scales for Mammography Screening. Its aim (1) is to provide data about and (2) to assess Turkish women's attitudes and behaviours towards mammography. The proportion of women who have mammography is lower in Turkey. The Champion's Health Belief Model Scales for Mammography Screening-Turkish version can be helpful to determine Turkish women's health beliefs, particularly about mammography. Cross-sectional design was used to collect survey data from Turkish women: classical measurement method. The Champion's Health Belief Model Scales for Mammography Screening was translated from English to Turkish. Again, it was back translated into English. Later, the meaning and clarity of the scale items were evaluated by a bilingual group representing the culture of the target population. Finally, the tool was evaluated by two bilingual professional researchers in terms of content validity, translation validity and psychometric estimates of the validity and reliability. The analysis included a total of 209 Turkish women. The validity of the scale was confirmed by confirmatory factor analysis and criterion-related validity testing. The Champion's Health Belief Model Scales for Mammography Screening aligned to four factors that were coherent and relatively independent of each other. There was a statistically significant relationship among all of the subscale items: the positive and high correlation of the total item test score and high Cronbach's α. The scale has a strong stability over time: the Champion's Health Belief Model Scales for Mammography Screening demonstrated acceptable preliminary values of reliability and validity. The Champion's Health Belief Model Scales for Mammography Screening is both a reliable and valid instrument that can be useful in measuring the health beliefs of Turkish women. It can be used to provide data

  13. Estimating the relative utility of screening mammography.

    PubMed

    Abbey, Craig K; Eckstein, Miguel P; Boone, John M

    2013-05-01

    The concept of diagnostic utility is a fundamental component of signal detection theory, going back to some of its earliest works. Attaching utility values to the various possible outcomes of a diagnostic test should, in principle, lead to meaningful approaches to evaluating and comparing such systems. However, in many areas of medical imaging, utility is not used because it is presumed to be unknown. In this work, we estimate relative utility (the utility benefit of a detection relative to that of a correct rejection) for screening mammography using its known relation to the slope of a receiver operating characteristic (ROC) curve at the optimal operating point. The approach assumes that the clinical operating point is optimal for the goal of maximizing expected utility and therefore the slope at this point implies a value of relative utility for the diagnostic task, for known disease prevalence. We examine utility estimation in the context of screening mammography using the Digital Mammographic Imaging Screening Trials (DMIST) data. We show how various conditions can influence the estimated relative utility, including characteristics of the rating scale, verification time, probability model, and scope of the ROC curve fit. Relative utility estimates range from 66 to 227. We argue for one particular set of conditions that results in a relative utility estimate of 162 (±14%). This is broadly consistent with values in screening mammography determined previously by other means. At the disease prevalence found in the DMIST study (0.59% at 365-day verification), optimal ROC slopes are near unity, suggesting that utility-based assessments of screening mammography will be similar to those found using Youden's index.

  14. Comparative effectiveness of mailed reminder letters on mammography screening compliance.

    PubMed

    Romaire, Melissa A; Bowles, Erin J Aiello; Anderson, Melissa L; Buist, Diana S M

    2012-08-01

    Reminder letters are effective at prompting women to schedule mammograms. Less well studied are reminders addressing multiple preventive service recommendations. We compared the effectiveness of a mammogram-specific reminder sent when a woman was due for a mammogram to a reminder letter addressing multiple preventive services and sent on a woman's birthday on mammography receipt. The study included 48,583 women 52-74 years enrolled in Group Health Cooperative, a health plan in Washington State. From 2005 to 2009, women were mailed 88,605 mammogram-specific or birthday letters. In this one group pretest-posttest study, we modeled the odds of obtaining a screening mammogram after receiving a letter by reminder type using logistic regression, controlling for demographic and healthcare use characteristics and stratifying by whether women were overdue or up-to-date with mammography at the mailing. Among women up-to-date with screening, birthday letters were negatively associated with mammography receipt compared to mammogram-specific letters (birthday letters with 1-2 recommendations: OR=0.73; 95% CI:0.68-0.79; 3 recommendations: OR=0.74; 95% CI:0.69-0.78; 4-8 recommendations: OR=0.62 95% CI:0.55-0.68) after. Among overdue women, birthday letters with 4-8 recommendations were negatively associated with mammography receipt. Transitioning from mammogram-specific reminder letters to multiple preventive service birthday letters was associated with decreased mammography receipt. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Digital Mammography in Young Women: Is a Single View Sufficient?

    PubMed

    Gossner, Johannes

    2016-03-01

    Single view mammography may be a less time consuming, more comfortable and radiation reduced alternative for young women, but there are no studies examining this approach after the implementation of digital mammography into clinical practice. Retrospective analysis of all mammographies performed in women younger than 40 years during a 24 month period. The sample consisted of 109 women with 212 examined breasts. All patients initially received standard two- view mammography. In the study setting the MLO- views were read by a single viewer and compared to a composite reference standard. In this sample 7 malignant findings were present and the review of the MLO-view detected 6 of them (85%). In patients with dense breasts 4 out of 5 malignant findings were found on the single-view (sensitivity 80%) and all 2 malignant findings were detected in patients with low breast density (sensitivity 100%). There were 7 false positive findings (3.3%). i.e. in total 8 out of 212 examined breasts were therefore misinterpreted (3.8%). Single view digital mammography detects the vast majority of malignant findings, especially in low density breast tissue and the rate of false-positive findings is within acceptable limits. Therefore this approach may be used in different scenarios (for example in increasing patient throughout in resource poor settings, reducing radiation burden in the young or in combination with ultrasound to use the strengths of both methods). More research on this topic is needed to establish its potential role in breast imaging.

  16. Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program

    PubMed Central

    Zuckerman, Samantha P.; Keller, Brad M.; Maidment, Andrew D. A.; Barufaldi, Bruno; Weinstein, Susan P.; Synnestvedt, Marie; McDonald, Elizabeth S.

    2016-01-01

    Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board–approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016. PMID:27467468

  17. Breast cancer screening and problem solving using mammography, ultrasound, and magnetic resonance imaging.

    PubMed

    Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M

    2011-03-01

    Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.

  18. Mammographic density is the main correlate of tumors detected on ultrasound but not on mammography.

    PubMed

    Häberle, Lothar; Fasching, Peter A; Brehm, Barbara; Heusinger, Katharina; Jud, Sebastian M; Loehberg, Christian R; Hack, Carolin C; Preuss, Caroline; Lux, Michael P; Hartmann, Arndt; Vachon, Celine M; Meier-Meitinger, Martina; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger

    2016-11-01

    Although mammography screening programs do not include ultrasound examinations, some diagnostic units do provide women with both mammography and ultrasonography. This article is concerned with estimating the risk of a breast cancer patient diagnosed in a hospital-based mammography unit having a tumor that is visible on ultrasound but not on mammography. A total of 1,399 women with invasive breast cancer from a hospital-based diagnostic mammography unit were included in this retrospective study. For inclusion, mammograms from the time of the primary diagnosis had to be available for computer-assisted assessment of percentage mammographic density (PMD), as well as Breast Imaging Reporting and Data System (BIRADS) assessment of mammography. In addition, ultrasound findings were available for the complete cohort as part of routine diagnostic procedures, regardless of any patient or imaging characteristics. Logistic regression analyses were conducted to identify predictors of mammography failure, defined as BIRADS assessment 1 or 2. The probability that the visibility of a tumor might be masked at diagnosis was estimated using a regression model with the identified predictors. Tumors were only visible on ultrasound in 107 cases (7.6%). PMD was the strongest predictor for mammography failure, but age, body mass index and previous breast surgery also influenced the risk, independently of the PMD. Risk probabilities ranged from 1% for a defined low-risk group up to 40% for a high-risk group. These findings might help identify women who should be offered ultrasound examinations in addition to mammography. © 2016 UICC.

  19. Implications of Overdiagnosis: Impact on Screening Mammography Practices

    PubMed Central

    Morris, Elizabeth; Feig, Stephen A.; Drexler, Madeline

    2015-01-01

    Abstract This review article explores the issue of overdiagnosis in screening mammography. Overdiagnosis is the screen detection of a breast cancer, histologically confirmed, that might not otherwise become clinically apparent during the lifetime of the patient. While screening mammography is an imperfect tool, it remains the best tool we have to diagnose breast cancer early, before a patient is symptomatic and at a time when chances of survival and options for treatment are most favorable. In 2015, an estimated 231,840 new cases of breast cancer (excluding ductal carcinoma in situ) will be diagnosed in the United States, and some 40,290 women will die. Despite these data, screening mammography for women ages 40–69 has contributed to a substantial reduction in breast cancer mortality, and organized screening programs have led to a shift from late-stage diagnosis to early-stage detection. Current estimates of overdiagnosis in screening mammography vary widely, from 0% to upwards of 30% of diagnosed cancers. This range reflects the fact that measuring overdiagnosis is not a straightforward calculation, but usually one based on different sets of assumptions and often biased by methodological flaws. The recent development of tomosynthesis, which creates high-resolution, three-dimensional images, has increased breast cancer detection while reducing false recalls. Because the greatest harm of overdiagnosis is overtreatment, the key goal should not be less diagnosis but better treatment decision tools. (Population Health Management 2015;18:S3–S11) PMID:26414384

  20. The interaction of perceived risk and benefits and its relationship to predicting mammography adherence in African-American women

    PubMed Central

    Fair, Alecia Malin; Monahan, Patrick O.; Russell, Kathleen; Zhao, Qianqian; Champion, Victoria L.

    2013-01-01

    PURPOSE/OBJECTIVES To test the interaction of perceived risk and benefits on stage of mammography readiness and adherence. DESIGN Cross-sectional study SETTING Community gathering places and health care clinics across a Midwestern state. SAMPLE 299 African-American women who had not had a mammogram in ≥ 18 months. METHODS In-person interviews were used to collect data on sociodemographics, health belief variables and stage of readiness to undertake mammography screening. Four categories were created to measure the combined magnitude of high/low levels of perceived risk and benefit with health belief variables linked to modifying mammography screening behavior. MAIN RESEARCH VARIABLES Perceived risks and benefits, stage of readiness, mammography adherence. FINDINGS The lowest rate of mammography adherence was in women with a high perceived risk and low benefit towards mammography adherence (25.6) compared to women with a high perceived benefit and low risk towards mammography adherence (46.0). Differences in mammography adherence were statistically significant between these groups p=(0.009). CONCLUSIONS The interaction of high perceived risk and low benefits additively effected readiness to undertake screening mammography. IMPLICATIONS FOR NURSING Reducing disparities in breast cancer diagnosis and survival requires timely and efficient mammography adherence. Minority, medically underserved women with perceived high risk and low benefits exhibit immobilization to move forward with mammography adherence when they experience higher perceived risk. Further interventions to increase the perception of benefit of mammography are recommended to reduce breast cancer mortality. PMID:22201655

  1. Knowledge, attitude and practice of mammography among women users of public health services.

    PubMed

    Marinho, Luiz Alberto Barcelos; Cecatti, José Guilherme; Osis, Maria José Duarte; Gurgel, Maria Salete Costa

    2008-04-01

    To evaluate knowledge, attitude and practice related to mammography among women users of local health services, identifying barriers to its performance. A total of 663 women were interviewed at 13 local health centers in a city of Southeastern Brazil, in 2001. Interviewees were randomly selected at each center and they were representative from different socioeconomic conditions. The number of interviewees at each center was proportional to monthly mean appointments. For data analysis, answers were described as knowledge, attitude, practice and their respective adequacies and then they were correlated with control variables through the chi-square test. Only 7.4% of the interviewees had adequate knowledge on mammography, while 97.1% of women had an adequate attitude. The same was seen for the practice of mammography that was adequate in 35.7% of the cases. The main barrier to mammography was lack of referral by physicians working at the health center (81.8%). There was an association between adequacy of attitude and five years or more of education and being married. There was also an association between adequacy of mammography practice and being employed and family income up to four minimum wages. Women users of local health services had no adequate knowledge and practice related to mammography despite having an adequate attitude about this exam.

  2. The interaction of perceived risk and benefits and the relationship to predicting mammography adherence in African American women.

    PubMed

    Fair, Alecia Malin; Monahan, Patrick O; Russell, Kathleen; Zhao, Qianqian; Champion, Victoria L

    2012-01-01

    To test the interaction of perceived risk and benefits and how they impact stage of mammography readiness and adherence. Cross-sectional study. Community gathering centers and healthcare clinics across Indiana. 299 African American women who had not had a mammogram in more than 18 months. In-person interviews were used to collect data on sociodemographics, health belief variables, and stage of readiness to undertake mammography screening. Four categories were created to measure the combined magnitude of high or low levels of perceived risk and benefit, with health belief variables linked to modified mammography screening behavior. Perceived risks and benefits, stage of readiness, and mammography adherence. The lowest rate of mammography adherence was in women with a high perceived risk and low perceived benefit toward mammography adherence (26%). The highest rate of adherence was in women with a high perceived benefit and low perceived risk (46%). Differences in mammography adherence were statistically significant between the groups (p = 0.009). The interaction of high perceived risk and low perceived benefits impacted readiness to undergo screening mammography. Reducing disparities in breast cancer diagnosis and survival requires timely and efficient mammography adherence. African American medically underserved women with high perceived risk and low perceived benefits exhibited a reluctance to move forward with mammography adherence. Interventions are needed to increase the perception of mammography benefit and to subsequently reduce breast cancer mortality rates in that population.

  3. Automatic patient dose registry and clinical audit on line for mammography.

    PubMed

    Ten, J I; Vano, E; Sánchez, R; Fernandez-Soto, J M

    2015-07-01

    The use of automatic registry systems for patient dose in digital mammography allows clinical audit and patient dose analysis of the whole sample of individual mammography exposures while fulfilling the requirements of the European Directives and other international recommendations. Further parameters associated with radiation exposure (tube voltage, X-ray tube output and HVL values for different kVp and target/filter combinations, breast compression, etc.) should be periodically verified and used to evaluate patient doses. This study presents an experience in routine clinical practice for mammography using automatic systems. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Effectiveness of Computer-Aided Detection in Community Mammography Practice

    PubMed Central

    Abraham, Linn; Taplin, Stephen H.; Geller, Berta M.; Carney, Patricia A.; D’Orsi, Carl; Elmore, Joann G.; Barlow, William E.

    2011-01-01

    Background Computer-aided detection (CAD) is applied during screening mammography for millions of US women annually, although it is uncertain whether CAD improves breast cancer detection when used by community radiologists. Methods We investigated the association between CAD use during film-screen screening mammography and specificity, sensitivity, positive predictive value, cancer detection rates, and prognostic characteristics of breast cancers (stage, size, and node involvement). Records from 684 956 women who received more than 1.6 million film-screen mammograms at Breast Cancer Surveillance Consortium facilities in seven states in the United States from 1998 to 2006 were analyzed. We used random-effects logistic regression to estimate associations between CAD and specificity (true-negative examinations among women without breast cancer), sensitivity (true-positive examinations among women with breast cancer diagnosed within 1 year of mammography), and positive predictive value (breast cancer diagnosed after positive mammograms) while adjusting for mammography registry, patient age, time since previous mammography, breast density, use of hormone replacement therapy, and year of examination (1998–2002 vs 2003–2006). All statistical tests were two-sided. Results Of 90 total facilities, 25 (27.8%) adopted CAD and used it for an average of 27.5 study months. In adjusted analyses, CAD use was associated with statistically significantly lower specificity (OR = 0.87, 95% confidence interval [CI] = 0.85 to 0.89, P < .001) and positive predictive value (OR = 0.89, 95% CI = 0.80 to 0.99, P = .03). A non-statistically significant increase in overall sensitivity with CAD (OR = 1.06, 95% CI = 0.84 to 1.33, P = .62) was attributed to increased sensitivity for ductal carcinoma in situ (OR = 1.55, 95% CI = 0.83 to 2.91; P = .17), although sensitivity for invasive cancer was similar with or without CAD (OR = 0.96, 95% CI = 0.75 to 1.24; P = .77). CAD was not associated with

  5. The Assessment of the Likelihood of Mammography Usage with Relevant Factors among Women with Disabilities

    ERIC Educational Resources Information Center

    Kung, Pei-Tseng; Tsai, Wen-Chen; Chiou, Shang-Jyh

    2012-01-01

    Research that identifies the determinants of low mammography use among disabled people is scant. This study examines the determining factors related to the low usage of mammography among women with disabilities. To identify the barriers that prevent women with disabilities from participating in mammography screening can help authorities conceive…

  6. Cultural Views, Language Ability, and Mammography Use in Chinese American Women

    ERIC Educational Resources Information Center

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S.

    2009-01-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a…

  7. Si-strip photon counting detectors for contrast-enhanced spectral mammography

    NASA Astrophysics Data System (ADS)

    Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.

    2015-08-01

    We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.

  8. Predictors of mammography screening among ethnically diverse low-income women.

    PubMed

    Cronan, Terry A; Villalta, Ian; Gottfried, Emily; Vaden, Yavette; Ribas, Mabel; Conway, Terry L

    2008-05-01

    Breast cancer is the second leading cause of cancer deaths among women in the United States. Minority women are less likely to be screened and more likely to die from breast cancer than are Caucasian women. Although some studies have examined ethnic disparities in mammography screening, no study has examined whether there are ethnic disparities among low-income, ethnically diverse women. The present study was designed to determine whether there are ethnic disparities in mammography screening and predictors of screening among low-income African American, Mexican American, and Caucasian women, and to determine whether the disparities and predictors vary across ethnic groups. The participants were 146 low-income women who were Mexican American (32%), African American (31%), or Caucasian (37%). Statistical analyses were performed to assess the relationships between mammography screening during the past 2 years and potential predictors of screening, both within ethnic groups and for the combined sample. The results varied depending on whether analyses combined ethnic groups or were performed within each of the three ethnic groups. It is, therefore, important to examine within-group differences when examining ethnic disparities in predictors of mammography.

  9. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    NASA Astrophysics Data System (ADS)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  10. Do mammographic technologists affect radiologists’ diagnostic mammography interpretative performance?

    PubMed Central

    Henderson, Louise M.; Benefield, Thad; Bowling, J. Michael; Durham, Danielle; Marsh, Mary W.; Schroeder, Bruce F.; Yankaskas, Bonnie C.

    2015-01-01

    Objective The purpose of this study was to determine whether the technologist has an effect on the radiologists’ interpretative performance of diagnostic mammography. Materials and Methods Using data from a community based mammography registry from 1994 to 2009, we identified 162,755 diagnostic mammograms interpreted by 286 radiologists and performed by 303 mammographic technologists. We calculated sensitivity, false positive rate, and positive predictive value of biopsy (PPV2) for examinations performed (images taken) by each mammographic technologist, separately for film and digital modalities. We assessed the variability of these performance measures among mammographic technologists, using mixed effects logistic regression and taking into account the clustering of examinations within women, radiologists, and radiology practice. Results Among the 291 technologists performing film examinations, mean sensitivity of the examinations they performed was 83.0% (95% Confidence Interval (CI)=80.8–85.2%), mean false positive rate was 8.5 per 1000 examinations (95%CI: 8.0–9.0%), and mean PPV2 was 27.1% (95%CI: 24.8–29.4). For the 45 technologists performing digital examinations, mean sensitivity of the examinations they performed was 79.6% (95%CI: 73.1–86.2%), mean false positive rate was 8.8 (95%CI: 7.5–10.0%), and mean PPV2 was 23.6% (95%CI: 18.8–28.4%). We found significant variation by technologist in the sensitivity, false positive rate, and PPV2 for film but not digital mammography (p<0.0001 for all 3 film performance measures). Conclusions Our results suggest that the technologist has an influence on radiologists’ performance of diagnostic film mammography but not digital. Future work should examine why this difference by modality exists and determine if similar patterns are observed for screening mammography. PMID:25794085

  11. Cross-national comparison of screening mammography accuracy measures in U.S., Norway, and Spain.

    PubMed

    Domingo, Laia; Hofvind, Solveig; Hubbard, Rebecca A; Román, Marta; Benkeser, David; Sala, Maria; Castells, Xavier

    2016-08-01

    To compare accuracy measures for mammographic screening in Norway, Spain, and the US. Information from women aged 50-69 years who underwent mammographic screening 1996-2009 in the US (898,418 women), Norway (527,464), and Spain (517,317) was included. Screen-detected cancer, interval cancer, and the false-positive rates, sensitivity, specificity, positive predictive value (PPV) for recalls (PPV-1), PPV for biopsies (PPV-2), 1/PPV-1 and 1/PPV-2 were computed for each country. Analyses were stratified by age, screening history, time since last screening, calendar year, and mammography modality. The rate of screen-detected cancers was 4.5, 5.5, and 4.0 per 1000 screening exams in the US, Norway, and Spain respectively. The highest sensitivity and lowest specificity were reported in the US (83.1 % and 91.3 %, respectively), followed by Spain (79.0 % and 96.2 %) and Norway (75.5 % and 97.1 %). In Norway, Spain and the US, PPV-1 was 16.4 %, 9.8 %, and 4.9 %, and PPV-2 was 39.4 %, 38.9 %, and 25.9 %, respectively. The number of women needed to recall to detect one cancer was 20.3, 6.1, and 10.2 in the US, Norway, and Spain, respectively. Differences were found across countries, suggesting that opportunistic screening may translate into higher sensitivity at the cost of lower specificity and PPV. • Positive predictive value is higher in population-based screening programmes in Spain and Norway. • Opportunistic mammography screening in the US has lower positive predictive value. • Screening settings in the US translate into higher sensitivity and lower specificity. • The clinical burden may be higher for women screened opportunistically.

  12. Short-Term Outcomes of Screening Mammography Using Computer-Aided Detection

    PubMed Central

    Fenton, Joshua J.; Xing, Guibo; Elmore, Joann G.; Bang, Heejung; Chen, Steven L.; Lindfors, Karen K.; Baldwin, Laura-Mae

    2013-01-01

    Background Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect. Objective To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing. Design Retrospective cohort study. Setting Medicare program. Participants Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women). Measurements Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer. Results From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]). Limitation Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women. Conclusion Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer. Primary Funding Source Center for Healthcare Policy and Research, University of California, Davis. PMID

  13. 78 FR 13681 - Agency Information Collection Activities; Proposed Collection; Comment Request; Mammography...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ...The Food and Drug Administration (FDA) is announcing an opportunity for public comment on the proposed collection of certain information by the Agency. Under the Paperwork Reduction Act of 1995 (the PRA), Federal Agencies are required to publish notice in the Federal Register concerning each proposed collection of information, including each proposed extension of an existing collection of information, and to allow 60 days for public comment in response to the notice. This notice solicits comments on the estimated reporting, recordkeeping, and third-party disclosure burden associated with the Mammography Quality Standards Act requirements.

  14. 75 FR 11542 - Agency Information Collection Activities; Proposed Collection; Comment Request; Mammography...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ...The Food and Drug Administration (FDA) is announcing an opportunity for public comment on the proposed collection of certain information by the agency. Under the Paperwork Reduction Act of 1995 (the PRA), Federal agencies are required to publish notice in the Federal Register concerning each proposed collection of information, including each proposed extension of an existing collection of information, and to allow 60 days for public comment in response to the notice. This notice solicits comments on the estimated reporting and recordkeeping burden associated with the Mammography Quality Standards Act requirements.

  15. Continuing screening mammography in women aged 70 to 79 years: impact on life expectancy and cost-effectiveness.

    PubMed

    Kerlikowske, K; Salzmann, P; Phillips, K A; Cauley, J A; Cummings, S R

    1999-12-08

    Mammography is recommended and is cost-effective for women aged 50 to 69 years, but the value of continuing screening mammography after age 69 years is not known. In particular, older women with low bone mineral density (BMD) have a lower risk of breast cancer and may benefit less from continued screening. To compare life expectancy and cost-effectiveness of screening mammography in elderly women based on 3 screening strategies. Decision analysis and cost-effectiveness analysis using a Markov model. General population of women aged 65 years or older. The analysis compared 3 strategies: (1) Undergoing biennial mammography from age 65 to 69 years; (2) undergoing biennial mammography from age 65 to 69 years, measurement of distal radial BMD at age 65 years, discontinuing screening at age 69 years in women in the lowest BMD quartile for age, and continuing biennial mammography to age 79 years in those in the top 3 quartiles of distal radius BMD; and (3) undergoing biennial mammography from age 65 to 79 years. Deaths due to breast cancer averted, life expectancy, and incremental cost-effectiveness ratios. Compared with discontinuing mammography screening at age 69 years, measuring BMD at age 65 years in 10000 women and continuing mammography to age 79 years only in women with BMD in the top 3 quartiles would prevent 9.4 deaths and add, on average, 2.1 days to life expectancy at an incremental cost of $66773 per year of life saved. Continuing mammography to age 79 years in all 10000 elderly women would prevent 1.4 additional breast cancer deaths and add only 7.2 hours to life expectancy at an incremental cost of $117689 per year of life saved compared with only continuing mammography to age 79 years in women with BMD in the top 3 quartiles. This analysis suggests that continuing mammography screening after age 69 years results in a small gain in life expectancy and is moderately cost-effective in those with high BMD and more costly in those with low BMD. Women

  16. Surveillance mammography among female Department of Defense beneficiaries: a study by race and ethnicity.

    PubMed

    Enewold, Lindsey; McGlynn, Katherine A; Zahm, Shelia H; Jatoi, Ismail; Anderson, William F; Gill, Abegail A; Shriver, Craig D; Zhu, Kangmin

    2013-10-01

    Annual surveillance mammography is recommended after a diagnosis of breast cancer. Previous studies have suggested that surveillance mammography varies by demographics and initial tumor characteristics, which are related to an individual's access to health care. The Military Health System of the Department of Defense provides beneficiaries with equal access health care and thus offers an excellent opportunity to assess whether racial differences in surveillance mammography persist when access to care is equal. Among female beneficiaries with a history of breast cancer, logistic regression was used to assess racial/ethnic variations in the use of surveillance mammography during 3 periods of 12 months each, beginning 1 year after diagnosis adjusting for demographic, tumor, and health characteristics. The rate of overall surveillance mammography decreased from 70% during the first year to 59% during the third year (P < .01). Although there was an overall tendency for surveillance mammography to be higher among minority women compared with non-Hispanic white women, after adjusting for covariates, the difference was found to be significant only during the first year among black women (odds ratio [OR], 1.46; 95% confidence interval [95% CI], 1.10-1.95) and the second year among Asian/Pacific Islander (OR, 2.29; 95%CI, 1.52-3.44) and Hispanic (OR, 1.92; 95%CI, 1.17-3.18) women. When stratified by age at diagnosis and type of breast cancer surgery performed, significant racial differences tended to be observed among younger women (aged < 50 years) and only among women who had undergone mastectomies. Minority women were equally or more likely than non-Hispanic white women to receive surveillance mammography within the Military Health System. The racial disparities in surveillance mammography reported in other studies were not observed in a system with equal access to health care. Copyright © 2013 American Cancer Society.

  17. Contrast Enhanced Spectral Mammography: A Review.

    PubMed

    Patel, Bhavika K; Lobbes, M B I; Lewin, John

    2018-02-01

    Contrast-enhanced spectral mammography (CESM) provides low-energy 2D mammographic images comparable to standard digital mammography and a post-contrast recombined image to assess tumor neovascularity similar to magnetic resonance imaging (MRI). The utilization of CESM in the United States is currently low but could increase rapidly given many potential indications for clinical use. This article discusses historical background and literature review of indications and diagnostic accuracy of CESM to date. CESM is a growing technique for breast cancer detection and diagnosis that has levels of sensitivity and specificity on par with contrast-enhanced breast MRI. Because of its similar performance and ease of implementation, CESM is being adopted for multiple indications previously reserved for MRI, such as problem-solving, disease extent in newly diagnosed patients, and evaluating the treatment response of neoadjuvant chemotherapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Satellite teleradiology test bed for digital mammography

    NASA Astrophysics Data System (ADS)

    Barnett, Bruce G.; Dudding, Kathryn E.; Abdel-Malek, Aiman A.; Mitchell, Robert J.

    1996-05-01

    Teleradiology offers significant improvement in efficiency and patient compliance over current practices in traditional film/screen-based diagnosis. The increasing number of women who need to be screened for breast cancer, including those in remote rural regions, make the advantages of teleradiology especially attractive for digital mammography. At the same time, the size and resolution of digital mammograms are among the most challenging to support in a cost effective teleradiology system. This paper will describe a teleradiology architecture developed for use with digital mammography by GE Corporate Research and Development in collaboration with Massachusetts General Hospital under National Cancer Institute (NCI/NIH) grant number R01 CA60246-01. The testbed architecture is based on the Digital Imaging and Communications in Medicine (DICOM) standard, created by the American College of Radiology and National Electrical Manufacturers Association. The testbed uses several Sun workstations running SunOS, which emulate a rural examination facility connected to a central diagnostic facility, and uses a TCP-based DICOM application to transfer images over a satellite link. Network performance depends on the product of the bandwidth times the round- trip time. A satellite link has a round trip of 513 milliseconds, making the bandwidth-delay a significant problem. This type of high bandwidth, high delay network is called a Long Fat Network, or LFN. The goal of this project was to quantify the performance of the satellite link, and evaluate the effectiveness of TCP over an LFN. Four workstations have Sun's HSI/S (High Speed Interface) option. Two are connected by a cable, and two are connected through a satellite link. Both interfaces have the same T1 bandwidth (1.544 Megabits per second). The only difference was the round trip time. Even with large window buffers, the time to transfer a file over the satellite link was significantly longer, due to the bandwidth-delay. To

  19. Cost-effectiveness comparison of five interventions to increase mammography screening.

    PubMed

    Saywell, R M; Champion, V L; Skinner, C S; McQuillen, D; Martin, D; Maraj, M

    1999-11-01

    Mammography is the primary method used for breast cancer screening. However, compliance with recommended screening practices is still below acceptable levels. This study examined the cost-effectiveness of five combinations of physician recommendation and telephone or in-person individualized counseling strategies for increasing compliance with mammography. There were 808 participants who were randomly assigned to one of six groups. A logistic regression model with compliance as the dependent variable and group as the independent variable was used to test for significant differences and a ratio of cost to improvement in mammogram compliance evaluated the cost-effectiveness. Three of the interventions (in-person, telephone plus letter, and in-person plus letter) had significantly better compliance rates compared with the control, physician letter, or telephone alone. However, when considering costs, only one emerged as the superior strategy. The cost-effectiveness ratios for the five interventions show that telephone-plus-letter is the most cost-effective strategy, achieving a 35.6% mammography compliance at a marginal cost of $0.78 per 1% increase in women screened. A tailored phone prompt and physician reminder is an effective and economical intervention to increase mammography. Future research should confirm this finding and address its applicability to practice. Copyright 1999 American Health Foundation and Academic Press.

  20. Are women getting relevant information about mammography screening for an informed consent: a critical appraisal of information brochures used for screening invitation in Germany, Italy, Spain and France.

    PubMed

    Gummersbach, Elisabeth; Piccoliori, Giuliano; Zerbe, Cristina Oriol; Altiner, Attila; Othman, Cecile; Rose, Christine; Abholz, Heinz-Harald

    2010-08-01

    The aim was to find out if information brochures on mammography screening in Germany, Italy, Spain and France contain more information to facilitate informed consent than in similar studies carried out over the last few years in Sweden, Canada, USA and the UK, countries with different medical cultures. We generated a list of essential information items on mammography screening for the purpose of informed consent. We mostly used the same items of information as had been used in previous studies and analysed the information brochures of major national initiatives in Germany and France, and three brochures each from regionalized programmes in Italy and Spain. We cross-checked which of our items were covered in the brochures and if correct numbers were given. We found that the information brochures contained only about half of the information items we defined. Six of the eight brochures mentioned the reduction in breast-cancer fatalities. Four of the eight provided information on false positives, and four of the brochures highlighted the side-effects of radiation. The information on side-effects and risks provided by the brochures was generally of poor quality, and none of them referred to over diagnosis. When numbers were given, they were only indicated in terms of relative numbers. The information brochures currently being used in Germany, Italy, Spain and France are no better than the brochures analysed some years ago. Our results suggest that the providers of mammography screening programmes continue to conceal information from women that is essential when making an informed decision.

  1. Breast mass detection in mammography and tomosynthesis via fully convolutional network-based heatmap regression

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Cain, Elizabeth Hope; Saha, Ashirbani; Zhu, Zhe; Mazurowski, Maciej A.

    2018-02-01

    Breast mass detection in mammography and digital breast tomosynthesis (DBT) is an essential step in computerized breast cancer analysis. Deep learning-based methods incorporate feature extraction and model learning into a unified framework and have achieved impressive performance in various medical applications (e.g., disease diagnosis, tumor detection, and landmark detection). However, these methods require large-scale accurately annotated data. Unfortunately, it is challenging to get precise annotations of breast masses. To address this issue, we propose a fully convolutional network (FCN) based heatmap regression method for breast mass detection, using only weakly annotated mass regions in mammography images. Specifically, we first generate heat maps of masses based on human-annotated rough regions for breast masses. We then develop an FCN model for end-to-end heatmap regression with an F-score loss function, where the mammography images are regarded as the input and heatmaps for breast masses are used as the output. Finally, the probability map of mass locations can be estimated with the trained model. Experimental results on a mammography dataset with 439 subjects demonstrate the effectiveness of our method. Furthermore, we evaluate whether we can use mammography data to improve detection models for DBT, since mammography shares similar structure with tomosynthesis. We propose a transfer learning strategy by fine-tuning the learned FCN model from mammography images. We test this approach on a small tomosynthesis dataset with only 40 subjects, and we show an improvement in the detection performance as compared to training the model from scratch.

  2. Digital Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters (TLDs)

    DTIC Science & Technology

    2003-06-18

    Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...34Digital Mammography Breast Dosimetry Using Copper- Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs )" Author: LT John J. Tomon...Title of Thesis: " Digital Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent

  3. Synthesized Mammography: Clinical Evidence, Appearance, and Implementation.

    PubMed

    Durand, Melissa A

    2018-04-04

    Digital breast tomosynthesis (DBT) has improved conventional mammography by increasing cancer detection while reducing recall rates. However, these benefits come at the cost of increased radiation dose. Synthesized mammography (s2D) has been developed to provide the advantages of DBT with nearly half the radiation dose. Since its F.D.A. approval, multiple studies have evaluated the clinical performance of s2D. In clinical practice, s2D images are not identical to conventional 2D images and are designed for interpretation with DBT as a complement. This article reviews the present literature to assess whether s2D is a practical alternative to conventional 2D, addresses the differences in mammographic appearance of findings, and provides suggestions for implementation into clinical practice.

  4. Impact of the Introduction of Digital Mammography in an Organized Screening Program on the Recall and Detection Rate.

    PubMed

    Campari, Cinzia; Giorgi Rossi, Paolo; Mori, Carlo Alberto; Ravaioli, Sara; Nitrosi, Andrea; Vacondio, Rita; Mancuso, Pamela; Cattani, Antonella; Pattacini, Pierpaolo

    2016-04-01

    In 2012, the Reggio Emilia Breast Cancer Screening Program introduced digital mammography in all its facilities at the same time. The aim of this work is to analyze the impact of digital mammography introduction on the recall rate, detection rate, and positive predictive value. The program actively invites women aged 45-74 years. We included women screened in 2011, all of whom underwent film-screen mammography, and all women screened in 2012, all of whom underwent digital mammography. Double reading was used for all mammograms, with arbitration in the event of disagreement. A total of 42,240 women underwent screen-film mammography and 45,196 underwent digital mammography. The recall rate increased from 3.3 to 4.4% in the first year of digital mammography (relative recall adjusted by age and round 1.46, 95% CI = 1.37-1.56); the positivity rate for each individual reading, before arbitration, rose from 3 to 5.7%. The digital mammography recall rate decreased during 2012: after 12 months, it was similar to the recall rate with screen-film mammography. The detection rate was similar: 5.9/1000 and 5.2/1000 with screen-film and digital mammography, respectively (adjusted relative detection rate 0.95, 95% CI = 0.79-1.13). The relative detection rate for ductal carcinoma in situ remained the same. The introduction of digital mammography to our organized screening program had a negative impact on specificity, thereby increasing the recall rate. The effect was limited to the first 12 months after introduction and was attenuated by the double reading with arbitration. We did not observe any relevant effects on the detection rate.

  5. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    NASA Astrophysics Data System (ADS)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  6. Breast masses in mammography classification with local contour features.

    PubMed

    Li, Haixia; Meng, Xianjing; Wang, Tingwen; Tang, Yuchun; Yin, Yilong

    2017-04-14

    Mammography is one of the most popular tools for early detection of breast cancer. Contour of breast mass in mammography is very important information to distinguish benign and malignant mass. Contour of benign mass is smooth and round or oval, while malignant mass has irregular shape and spiculated contour. Several studies have shown that 1D signature translated from 2D contour can describe the contour features well. In this paper, we propose a new method to translate 2D contour of breast mass in mammography into 1D signature. The method can describe not only the contour features but also the regularity of breast mass. Then we segment the whole 1D signature into different subsections. We extract four local features including a new contour descriptor from the subsections. The new contour descriptor is root mean square (RMS) slope. It can describe the roughness of the contour. KNN, SVM and ANN classifier are used to classify benign breast mass and malignant mass. The proposed method is tested on a set with 323 contours including 143 benign masses and 180 malignant ones from digital database of screening mammography (DDSM). The best accuracy of classification is 99.66% using the feature of root mean square slope with SVM classifier. The performance of the proposed method is better than traditional method. In addition, RMS slope is an effective feature comparable to most of the existing features.

  7. Subgroup-specific effects of questionnaire wording on population-based estimates of mammography prevalence.

    PubMed Central

    Siegel, P Z; Qualters, J R; Mowery, P D; Campostrini, S; Leutzinger, C; McQueen, D V

    2001-01-01

    OBJECTIVES: This study investigated whether an apparent downturn in prevalence rates of mammography use reported in the 1992 Behavioral Risk Factor Surveillance System (BRFSS) questionnaire resulted from a change in questionnaire wording. METHODS: In a pretest-posttest design (1990-1991 vs 1992), piecewise linear regression analyses were based on monthly prevalence estimates of mammography use among female BRFSS respondents 40 years or older. RESULTS: Self-reported mammography use was lower by 3.5 percentage points (95% confidence interval [CI] = 1.5, 5.5) overall--and lower by 13.6 percentage points (95% CI = 2.6, 24.6) among Black women with less than a high school education--when predicted from 1992 data than when predicted from 1990-1991 data. CONCLUSIONS: A change in questionnaire wording in the BRFSS caused demographic-specific effects in population-based estimates of mammography use. PMID:11344896

  8. Mammography film processor replenishment rate: bromide level monitoring.

    PubMed

    Kimme-Smith, C; Wuelfing, P; Kitts, E L; Cagnon, C; Basic, M; Bassett, L

    1997-03-01

    The effects of the mammography film processing replenishment rate on contrast and speed are studied sensitometrically. Two experiments studied decreasing replenishment rates in the Kodak RP developer and quantified changes in the developer by measuring bromide ion concentrations. First, values of NaBr concentration from 1.7 to 8.4 g/L, achieved by reducing the replenishment rate, were tested with sensitometry strips. Second, the developer replenishment rate of a high volume dedicated mammography processor was reduced by one-third, to 20 cm3/1560 cm2, so that the NaBr concentration rose from 2.0 to 12.36. Sensitometric results for four film types and patient films were tested for changes from standard values as NaBr concentration was restored to 3.31 g/L. Fifty-five clinical images obtained at 7.3-9.3 NaBr g/L were compared to their matching previous films, with NaBr levels of 2-3 g/L, for contrast and visibility of the skin line. For the range of the NaBr ion from 1.7 to 7 g/L, no significant sensitometric differences were found. Above 7 g/L, different film types had different sensitometric results. From 7.3 to 9.3 NaBr g/L, 47.5% of the clinical films reviewed by four radiologists had less contrast compared to previous films. Dedicated mammography processors with high film volume (i.e., those that do not have excessive oxidation or foreign dye problems) can operate at lower replenishment rates than are currently employed. All common mammography film types are stable at these lower replenishment rates up to 7.0 NaBr g/L.

  9. Development of cultural belief scales for mammography screening.

    PubMed

    Russell, Kathleen M; Champion, Victoria L; Perkins, Susan M

    2003-01-01

    To develop instruments to measure culturally related variables that may influence mammography screening behaviors in African American women. Instrumentation methodology. Community organizations and public housing in the Indianapolis, IN, area. 111 African American women with a mean age of 60.2 years and 64 Caucasian women with a mean age of 60 years. After item development, scales were administered. Data were analyzed by factor analysis, item analysis via internal consistency reliability using Cronbach's alpha, and independent t tests and logistic regression analysis to test theoretical relationships. Personal space preferences, health temporal orientation, and perceived personal control. Space items were factored into interpersonal and physical scales. Temporal orientation items were loaded on one factor, creating a one-dimensional scale. Control items were factored into internal and external control scales. Cronbach's alpha coefficients for the scales ranged from 0.76-0.88. Interpersonal space preference, health temporal orientation, and perceived internal control scales each were predictive of mammography screening adherence. The three tested scales were reliable and valid. Scales, on average, did not differ between African American and Caucasian populations. These scales may be useful in future investigations aimed at increasing mammography screening in African American and Caucasian women.

  10. Mammography in asymptomatic women aged 40-49 years

    PubMed Central

    Silva, Flávio Xavier; Katz, Leila; Souza, Alex Sandro Rolland; Amorim, Melania Maria Ramos

    2014-01-01

    OBJECTIVE To assess findings of mammography of and interventions resulting from breast cancer screening in women aged 40-49 years with no increased risk (typical risk) of breast cancer. METHODS This cross-sectional study evaluated women aged 40-49 years who underwent mammography screening in a mastology reference center in Recife, PE, Northeastern Brazil, between January 2010 and October 2011. Women with breast-related complaints, positive findings in the physical examination, or high risk of breast cancer were excluded. RESULTS The 1,000 mammograms performed were classified into the following Breast Imaging-Reporting and Data System (BI-RADS) categories BI-RADS 0, 232; BI-RADS 1, 294; BI-RADS 2, 294; BI-RADS 3, 16; BI-RADS 4A, 2; BI-RADS 5, 1. There was one case of grade II invasive ductal carcinoma and various interventions, including 469 ultrasound scans, 53 referrals to mastologists, 11 cytological examinations, and 8 biopsies. CONCLUSIONS Mammography screening in women aged 40-49 years with typical risk of breast cancer led to the performance of other interventions. However, it also resulted in increased costs without demonstrable efficacy in decreasing mortality. PMID:26039396

  11. Health Insurance Mandates, Mammography, and Breast Cancer Diagnoses

    PubMed Central

    Bitler, Marianne P.

    2016-01-01

    We examine the effects of state health insurance mandates requiring coverage of screening mammograms. We find evidence that mammography mandates significantly increased mammography screenings by 4.5–25 percent. Effects are larger for women with less than a high school degree in states that ban deductibles, a policy similar to a provision of federal health reform that eliminates cost-sharing for preventive care. We also find that mandates increased detection of early stage in-situ pre-cancers. Finally, we find a substantial proportion of the increased screenings were attributable to mandates that are not consistent with current recommendations of the American Cancer Society. PMID:29527253

  12. Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications.

    PubMed

    Bhimani, Chandni; Matta, Danielle; Roth, Robyn G; Liao, Lydia; Tinney, Elizabeth; Brill, Kristin; Germaine, Pauline

    2017-01-01

    Contrast-enhanced spectral mammography (CESM) combines the benefits of full field digital mammography with the concept of tumor angiogenesis. Technique and practical applications of CESM are discussed. An overview of the technique is followed by a demonstration of practical applications of CESM in our practice. We have successfully implemented CESM into our practice as a screening, diagnostic, staging, and treatment response tool. It is important to understand the technique of CESM and how to incorporate it into practice. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. Attitudes and Beliefs Associated with Mammography in a Multiethnic Population in Israel

    ERIC Educational Resources Information Center

    Baron-Epel, Orna

    2010-01-01

    This article highlights beliefs, attitudes, and barriers that are associated with mammography use in four distinct cultural and ethnic groups in Israel: veteran, ultra-orthodox, and immigrant Jewish and Arab women. A random telephone survey of 1,550 women was performed. Information from claims records concerning mammography use was obtained for…

  14. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.

    PubMed

    Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.

  15. Validation of the English and Spanish Mammography Beliefs and Attitudes Questionnaire.

    PubMed

    Lopez-McKee, Gloria; Bader, Julia

    2011-03-21

    Breast cancer is the leading cause of cancer deaths among Hispanic women in the United States. Unfortunately Hispanic women exhibit poor mammography screening participation, are diagnosed at later stages of the disease, and have lower survival rates than non-Hispanic white women. Several cultural and psycho-social factors have been found to influence mammography screening participation among Hispanic women. We will begin by presenting the theoretical framework that grounded this research program to develop an instrument to assess factors contributing to poor mammography participation among Hispanic women. We will also summarize the early stages in the development of the English and Spanish Mammography Beliefs and Attitudes Questionnaire (MBAQ and SMBAQ) for use with low-health-literacy Mexican-American women. Next we will describe the initial psychometric testing of the MBAQ/SMBAQ, after which we will present the psychometric testing of the SMBAQ with low-health-literacy women. This will be followed by a discussion of the modification of the MBAQ and SMBAQ subscales. We'll conclude with a discussion of the instruments and share our assessment regarding the limitations of this research program, where the program stands to date, and the implications for practice and future research.

  16. Evaluation of the Utility of Screening Mammography for High-Risk Women Undergoing Screening Breast MR Imaging.

    PubMed

    Lo, Glen; Scaranelo, Anabel M; Aboras, Hana; Ghai, Sandeep; Kulkarni, Supriya; Fleming, Rachel; Bukhanov, Karina; Crystal, Pavel

    2017-10-01

    Purpose To evaluate the value of mammography in detecting breast cancer in high-risk women undergoing screening breast magnetic resonance (MR) imaging. Materials and Methods An ethics-approved, retrospective review of prospective databases was performed to identify outcomes of 3934 screening studies (1977 screening MR imaging examinations and 1957 screening mammograms) performed between January 2012 and July 2014 in 1249 high-risk women. Performance measures including recall and cancer detection rates, sensitivity, specificity, and positive predictive values were calculated for both mammography and MR imaging. Results A total of 45 cancers (33 invasive and 12 ductal carcinomas in situ) were diagnosed, 43 were seen with MR imaging and 14 with both mammography and MR imaging. Additional tests (further imaging and/or biopsy) were recommended in 461 screening MR imaging studies (recall rate, 23.3%; 95% confidence interval [CI]: 21.5%, 25.2%), and mammography recalled 217 (recall rate, 11.1%; 95% CI: 9.7%, 12.6%). The cancer detection rate for MR imaging was 21.8 cancers per 1000 examinations (95% CI: 15.78, 29.19) and that for mammography was 7.2 cancers per 1000 examinations (95% CI: 3.92, 11.97; P < .001). Sensitivity and specificity of MR imaging were 96% and 78% respectively, and those of mammography were 31% and 89%, respectively (P < .001). Positive predictive value for MR imaging recalls was 9.3% (95% CI: 6.83%, 12.36%) and that for mammography recalls was 6.5% (95% CI: 3.57%, 10.59%). Conclusion Contemporaneous screening mammography did not have added value in detection of breast cancer for women who undergo screening MR imaging. Routine use of screening mammography in women undergoing screening breast MR imaging warrants reconsideration. © RSNA, 2017 Online supplemental material is available for this article.

  17. Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors

    NASA Astrophysics Data System (ADS)

    Ozsahin, I.; Unlu, M. Z.

    2014-03-01

    Breast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative result (missed cancer), and false-positive result which leads to suspecting cancer and suggests an unnecessary biopsy. In this work, a PEM scanner based on CdTe strip detectors is simulated via the Monte Carlo method and evaluated in terms of its spatial resolution, sensitivity, and image quality. The spatial resolution is found to be ~ 1 mm in all three directions. The results also show that CdTe strip detectors based PEM scanner can produce high resolution images for early diagnosis of breast cancer.

  18. Comparative Study Of Image Enhancement Algorithms For Digital And Film Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delgado-Gonzalez, A.; Sanmiguel, R. E.

    2008-08-11

    Here we discuss the application of edge enhancement algorithms on images obtained with a Mammography System which has a Selenium Detector and on the other hand, on images obtained from digitized film mammography. Comparative analysis of such images includes the study of technical aspects of image acquisition, storage, compression and display. A protocol for a local database has been created as a result of this study.

  19. Consumers' quality perception of national branded, national store branded, and imported store branded beef.

    PubMed

    Banović, Marija; Grunert, Klaus G; Barreira, Maria Madalena; Fontes, Magda Aguiar

    2010-01-01

    This study investigated the differences in the consumers' quality perception of national branded, national store branded, and imported store branded beef. Partial Least Squares analysis is used for modelling the quality perception process. Results show that consumers perceived national branded Carnalentejana beef, as better on all quality cues and quality aspects than the other two store branded beefs. Preference for Carnalentejana beef stayed highly consistent even after the blind test, where consumers differentiated this beef from the other two beef brands on all sensory dimensions: taste, tenderness, and juiciness, and chose it as the preferred one. Consumers utilized more perceived intrinsic cues to infer expected eating quality of store branded beefs.

  20. The Role of Social Capital in African-American Women's Use of Mammography

    PubMed Central

    Dean, Lorraine; Subramanian, SV; Williams, David R.; Armstrong, Katrina; Charles, Camille Zubrinsky; Kawachi, Ichiro

    2014-01-01

    Black/African-American women are more likely to get breast cancer at a young age and/or be diagnosed at a late disease stage, pointing to a greater need to promote mammography for Black women at earlier ages than are currently recommended. This study explores how perceived neighborhood social capital, that is, perceptions of how tight-knit a neighborhood is and what power that confers to neighborhood members, relates to use of mammography for Black women in Philadelphia. Living in a community with tight social ties (social cohesion) or that have a collective motivation for community change (collective efficacy) may increase the likelihood that an individual woman in that community will hear health messages from other community members and neighbors (diffusion of information) and will have access to health-related resources that allow them to engage in healthy behaviors. No prior studies have explored the role of social capital in decisions for mammography use. Using multilevel logistic regression, we analyzed self-report of mammography in the past year for 2,586, Black women over age 40 across 381 Philadelphia, Pennsylvania USA census tracts. Our study included individual demographic and aggregates of individual-level social capital data from the Public Health Management Corporation's 2004, 2006, and 2008 Community Health Database waves, and 2000 US Census sociodemographic characteristics. Individual perceptions that a Black woman's neighborhood had high social capital, specifically collective efficacy, had a positive and statistically significant association with mammography use (OR=1.40, CI: 1.05, 1.85). Our findings suggest that an individual woman's perception of greater neighborhood social capital may be related to increased mammography use. Although this analysis could not determine the direction of causality, it suggests that social capital may play a role in cancer preventive screening for African-American women in Philadelphia, which warrants further study

  1. Analysis of utilization patterns and associated costs of the breast imaging and diagnostic procedures after screening mammography.

    PubMed

    Vlahiotis, Anna; Griffin, Brian; Stavros, A Thomas; Margolis, Jay

    2018-01-01

    Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam. To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures. Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy) other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event), with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes. The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients), 6,987,399 breast ultrasounds (42.4% of patients), and 1,585,856 biopsies (10.3% of patients). Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD) costs for diagnostic mammograms of US$349 ($493), ultrasounds US$132 ($134), and biopsies US$1,938 ($2,343) contributed US$3.05 billion, US$0.92 billion, and US$3.07 billion, respectively, to annual diagnostic breast expenditures estimated at US$7.91 billion. The volume and expense of additional breast diagnostic testing, estimated at US$7.91 billion annually, underscores the need for technological improvements in the breast diagnostic landscape.

  2. Breast Cancer Screening, Mammography, and Other Modalities.

    PubMed

    Fiorica, James V

    2016-12-01

    This article is an overview of the modalities available for breast cancer screening. The modalities discussed include digital mammography, digital breast tomosynthesis, breast ultrasonography, magnetic resonance imaging, and clinical breast examination. There is a review of pertinent randomized controlled trials, studies and meta-analyses which contributed to the evolution of screening guidelines. Ultimately, 5 major medical organizations formulated the current screening guidelines in the United States. The lack of consensus in these guidelines represents an ongoing controversy about the optimal timing and method for breast cancer screening in women. For mammography screening, the Breast Imaging Reporting and Data System lexicon is explained which corresponds with recommended clinical management. The presentation and discussion of the data in this article are designed to help the clinician individualize breast cancer screening for each patient.

  3. Screening mammography uptake within Australia and Scotland in rural and urban populations

    PubMed Central

    Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M.; Henderson, Robert; Watson, Angus; Kyle, Richard G.; Hubbard, Gill; Mullen, Russell; Atherton, Iain

    2015-01-01

    Objective To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Method Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946–51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Results Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06–1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01–1.31). Conclusions The absence of rural–urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography. PMID:26844118

  4. Screening mammography uptake within Australia and Scotland in rural and urban populations.

    PubMed

    Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M; Henderson, Robert; Watson, Angus; Kyle, Richard G; Hubbard, Gill; Mullen, Russell; Atherton, Iain

    2015-01-01

    To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946-51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06-1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01-1.31). The absence of rural-urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography.

  5. Configuration of automatic exposure control on mammography units for computed radiography to match patient dose of screen film systems

    NASA Astrophysics Data System (ADS)

    Yang, Chang-Ying Joseph; Huang, Weidong

    2009-02-01

    Computed radiography (CR) is considered a drop-in addition or replacement for traditional screen-film (SF) systems in digital mammography. Unlike other technologies, CR has the advantage of being compatible with existing mammography units. One of the challenges, however, is to properly configure the automatic exposure control (AEC) on existing mammography units for CR use. Unlike analogue systems, the capture and display of digital CR images is decoupled. The function of AEC is changed from ensuring proper and consistent optical density of the captured image on film to balancing image quality with patient dose needed for CR. One of the preferences when acquiring CR images under AEC is to use the same patient dose as SF systems. The challenge is whether the existing AEC design and calibration process-most of them proprietary from the X-ray systems manufacturers and tailored specifically for SF response properties-can be adapted for CR cassettes, in order to compensate for their response and attenuation differences. This paper describes the methods for configuring the AEC of three different mammography units models to match the patient dose used for CR with those that are used for a KODAK MIN-R 2000 SF System. Based on phantom test results, these methods provide the dose level under AEC for the CR systems to match with the dose of SF systems. These methods can be used in clinical environments that require the acquisition of CR images under AEC at the same dose levels as those used for SF systems.

  6. National Water Quality Standards Database (NWQSD)

    EPA Pesticide Factsheets

    The National Water Quality Standards Database (WQSDB) provides access to EPA and state water quality standards (WQS) information in text, tables, and maps. This data source was last updated in December 2007 and will no longer be updated.

  7. From facts to arguments: A study of the 2014 Swiss controversy over systematic mammography screening.

    PubMed

    Perrenoud, Caroline; Stiefel, Friedrich; Bourquin, Céline

    2018-06-01

    The Swiss Medical Board (SMB) has recently revived the controversy over mammography screening by recommending to stop the introduction of new systematic mammography screening programs. This study aimed to examine the Swiss media coverage of the release of the SMB report. The dataset consisted of 25 newspaper and "medical magazine" articles, and TV/radio interviews. The analytic approach was based on argumentation theory. Authority and community arguments were the most frequent types of arguments. With respect to authority arguments, stakeholders for instance challenged or supported the expertise of the SMB by referring to the competence of external figures of authority. Community arguments were based on common values such as life (saved thanks to systematic mammography screening) and money (costs associated with unnecessary care induced by systematic mammography screening). The efficiency of mammography screening which was the key issue of the debate appeared to be largely eluded, and the question of what women should do endures. While interpersonal and interprofessional communication has become a major topic of interest in the medical community, it appears that media communication on mammography screening is still rather ineffective. We call in particular for a more fact-based discussion. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Magnetic Resonance Imaging as an Adjunct to Mammography for Breast Cancer Screening in Women at Less Than High Risk for Breast Cancer: A Health Technology Assessment

    PubMed Central

    Nikitovic-Jokic, Milica; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Among women at high risk for breast cancer, magnetic resonance imaging (MRI) has been suggested as a safe adjunct (supplemental) screening tool that can detect breast cancers missed on screening mammography, potentially reducing the number of deaths associated with the disease. However, the use of adjunct screening tests may also increase the number of false-positive test results, which may lead to unnecessary follow-up testing, as well as patient stress and anxiety. We investigated the benefits and harms of MRI as an adjunct to mammography compared with mammography alone for screening women at less than high risk (average or higher than average risk) for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects (DARE), Centre for Reviews and Dissemination (CRD) Health Technology Assessment Database, and National Health Service (NHS) Economic Evaluation Database, from January 2002 to January 2016, for evidence of effectiveness, harms, and diagnostic accuracy. Only studies evaluating the use of screening breast MRI as an adjunct to mammography in the specified populations were included. Results No studies in women at less than high risk for breast cancer met our inclusion criteria. Conclusions It remains uncertain if the use of adjunct screening breast MRI in women at less than high risk (average or higher than average risk) for breast cancer will reduce breast cancer–related mortality without significant increases in unnecessary follow-up testing and treatment. PMID:27990198

  9. Breast cancer risk from different mammography screening practices.

    PubMed

    Bijwaard, Harmen; Brenner, Alina; Dekkers, Fieke; van Dillen, Teun; Land, Charles E; Boice, John D

    2010-09-01

    Mammography screening is an accepted procedure for early detection of breast tumors among asymptomatic women. Since this procedure involves the use of X rays, it is itself potentially carcinogenic. Although there is general consensus about the benefit of screening for older women, screening practices differ between countries. In this paper radiation risks for these different practices are estimated using a new approach. We model breast cancer induction by ionizing radiation in a cohort of patients exposed to frequent X-ray examinations. The biologically based, mechanistic model provides a better foundation for the extrapolation of risks to different mammography screening practices than empirical models do. The model predicts that the excess relative risk (ERR) doubles when screening starts at age 40 instead of 50 and that a continuation of screening at ages 75 and higher carries little extra risk. The number of induced fatal breast cancers is estimated to be considerably lower than derived from epidemiological studies and from internationally accepted radiation protection risks. The present findings, if used in a risk-benefit analysis for mammography screening, would be more favorable to screening than estimates currently recommended for radiation protection. This has implications for the screening ages that are currently being reconsidered in several countries.

  10. Barriers and incentives for choosing to specialise in mammography: Qualitative analysis.

    PubMed

    Warren-Forward, H M; Taylor, J

    2017-02-01

    There is a projected shortage of radiographers working in breast screening and this study aimed to examine comments from open response questions from a mixed methods survey of current diagnostic radiography students on their perceptions of working in mammography. The survey asked three open ended questions: Justification of choice of modality in which they would want to specialise, why they believed there was a shortage of radiographers working in breast screening and any other comment about mammography. Reasons given for specialising in any modality was interest, feature of a modality, amount of clinical exposure during the degree program, personal issues and career prospects. Few current diagnostic radiography students indicated that they would be interested in specialising in breast imaging. They considered there to be a shortage of radiographers as breast imaging was seen to be repetitive, high pressure, intimate and gender biased. Lack of education, clinical exposure, limited career prospects and low pay were also discussed. Increasing education to the modality during the degree, allowing males to be involved in breast imaging and promoting part-time work in mammography while also working in other modalities may alter the perception that mammography offers a limited career pathway. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  11. Optical tomography as adjunct to x-ray mammography: methods and results

    NASA Astrophysics Data System (ADS)

    Khayat, Mario; Ichalalene, Zahia; Mincu, Niculae; Leblond, Fredéric; Guilman, Olga; Djeziri, Salim

    2007-02-01

    Recent years have seen significant efforts deployed to apply optical imaging techniques in clinical indications. Optical mammography as an adjunct to X-ray mammography is one such application. 3D optical mammography relies on the sensitivity of near-infrared light to endogenous breast chromophores in order to generate in vivo functional views of the breast. This work presents prospective tissue characterization results from a multi-site clinical study targeting optical tomography as an adjunct to conventional mammography. A 2 nd -generation multi-wavelength time-domain acquisition system was used to scan a wide population of women presenting normal or suspicious X-ray mammograms. Application specific algorithms based on a diffusive model of light transport were used to quantify the breast's optical properties and derive 3D images of physiological indices. Using histopathological findings as a gold standard, results confirm that optically derived parameters provide statistically significant discrimination between malignant and benign tissue in wide population of subjects. The methodology developed for case reviews, lesion delineation and characterization allows for better translation of the optical data to the more traditional x-ray paradigm while maintaining efficacy. They also point to the need for guidelines that facilitate correlation of optical data if those results are to be confirmed in a clinical setting.

  12. Colour application on mammography image segmentation

    NASA Astrophysics Data System (ADS)

    Embong, R.; Aziz, N. M. Nik Ab.; Karim, A. H. Abd; Ibrahim, M. R.

    2017-09-01

    The segmentation process is one of the most important steps in image processing and computer vision since it is vital in the initial stage of image analysis. Segmentation of medical images involves complex structures and it requires precise segmentation result which is necessary for clinical diagnosis such as the detection of tumour, oedema, and necrotic tissues. Since mammography images are grayscale, researchers are looking at the effect of colour in the segmentation process of medical images. Colour is known to play a significant role in the perception of object boundaries in non-medical colour images. Processing colour images require handling more data, hence providing a richer description of objects in the scene. Colour images contain ten percent (10%) additional edge information as compared to their grayscale counterparts. Nevertheless, edge detection in colour image is more challenging than grayscale image as colour space is considered as a vector space. In this study, we implemented red, green, yellow, and blue colour maps to grayscale mammography images with the purpose of testing the effect of colours on the segmentation of abnormality regions in the mammography images. We applied the segmentation process using the Fuzzy C-means algorithm and evaluated the percentage of average relative error of area for each colour type. The results showed that all segmentation with the colour map can be done successfully even for blurred and noisy images. Also the size of the area of the abnormality region is reduced when compare to the segmentation area without the colour map. The green colour map segmentation produced the smallest percentage of average relative error (10.009%) while yellow colour map segmentation gave the largest percentage of relative error (11.367%).

  13. Mammography Decision Aid Reduces Decisional Conflict for Women in Their Forties Considering Screening.

    PubMed

    Eden, Karen B; Scariati, Paula; Klein, Krystal; Watson, Lindsey; Remiker, Mark; Hribar, Michelle; Forro, Vanessa; Michaels, LeAnn; Nelson, Heidi D

    2015-12-01

    Clinical guidelines recommend a personalized approach to mammography screening for women in their forties; however, methods to do so are lacking. An evidence-based mammography screening decision aid was developed as an electronic mobile application and evaluated in a before-after study. The decision aid (Mammopad) included modules on breast cancer, mammography, risk assessment, and priority setting about screening. Women aged 40-49 years who were patients of rural primary care clinics, had no major risk factors for breast cancer, and no mammography during the previous year were invited to use the decision aid. Twenty women participated in pretesting of the decision aid and 75 additional women completed the before-after study. The primary outcome was decisional conflict measured before and after using Mammopad. Secondary outcomes included decision self-efficacy and intention to begin or continue mammography screening. Differences comparing measures before versus after use were determined using Wilcoxon signed rank tests. After using Mammopad, women reported reduced decisional conflict based on mean Decisional Conflict Scale scores overall (46.33 versus 8.33; Z = -7.225; p < 0.001) and on all subscales (p < 0.001). Women also reported increased mean Decision Self-Efficacy Scale scores (79.67 versus 95.73; Z = 6.816, p < 0.001). Although 19% of women changed their screening intentions, this was not statistically significant. Women reported less conflict about their decisions for mammography screening, and felt more confident to make decisions after using Mammopad. This approach may help guide women through the decision making process to determine personalized screening choices that are appropriate for them.

  14. FDA & digital mammography: why has FDA required full field digital mammography systems to be regulated as potentially dangerous devices for more than 10 years?

    PubMed

    Nields, Morgan W

    2010-05-01

    Digital mammography is routinely used in the US to screen asymptomatic women for breast cancer and currently over 50% of US screening centers employ the technology. In spite of FDAs knowledge that digital mammography requires less radiation than film mammography and that its equivalence has been proven in a prospective randomized trial, the agency has failed to allow the technology market access via the 510(k) pre market clearance pathway. As a result of the restrictive Pre Market Approval process, only four suppliers have received FDA approval. The resulting lack of a competitive market has kept costs high, restricted technological innovation, and impeded product improvements as a result of PMA requirements. Meanwhile, at least twelve companies are on the market in the EU and the resulting competitive market has lowered costs and provided increased technological choice. A cultural change with new leadership occurred in the early 90's at FDA. The historical culture at the Center for Devices and Radiological Health of collaboration and education gave way to one characterized by a lack of reliance on outside scientific expertise, tolerance of decision making by unqualified reviewers, and an emphasis on enforcement and punishment. Digital mammography fell victim to this cultural change and as a result major innovations like breast CT and computer aided detection technologies are also withheld from the market. The medical device law, currently under review by the Institute of Medicine, should be amended by the Congress so that new technologies can be appropriately classified in accordance with the risk based assessment classification system detailed in Chapter V of the Federal Food, Drug, and Cosmetic Act. A panel of scientific experts chartered by the NIH or IOM should determine the classification appropriate for new technologies that have no historical regulatory framework. This would be binding on FDA. Unless the law is changed we will likely again experience

  15. News media coverage of a women's health contraversy: how newspapers and TV outlets covered a recent debate over screening mammography.

    PubMed

    Steele, Whitney Randolph; Mebane, Felicia; Viswanath, K; Solomon, Janice

    2005-01-01

    Over the past decade, there have been several highly visible debates about mammography that have captured professional, public and media attention. This paper looks at newspaper and television news coverage of a controversial research letter in The Lancet by Gøtzsche and Olsen (2001) that concluded that screening mammography did not prevent deaths from breast cancer. The news pieces examined for this project were published between October 2001 and March 2002 in one of eight U.S. newspapers or aired on one of six national or cable news networks. The six-month period was divided into one-week segments; the numbers of articles published or stories aired in each week were graphed to examine patterns. Each newspaper article and television transcript was then reviewed to identify its main content area and the amount of coverage for each major event was quantified. The highest number of newspaper articles appeared to result from several events during the end of January through the beginning of February. These events included the publication of another meta-analysis of mammography that disputed the original letter's conclusion and a full-page New York Times advertisement paid for by major medical organizations stating their continued support for mammography. The greatest amount of television news coverage was devoted to the announcement of the official federal guidelines by the Secretary of Health and Human Services in late February. We conclude by discussing how the flow of news coverage of medical controversies can potentially impact the actions and reactions of the public, the medical community and health policy makers.

  16. Comparison of Two Different Educational Methods for Teachers' Mammography Based on the Health Belief Model.

    PubMed

    Heydari, Esmat; Noroozi, Azita

    2015-01-01

    Breast cancer is the most common cancer in women. One way to decrease the burden of this cancer is early detection through mammography. This study compared the effectiveness of two different educational methods for teachers' uptake of mammography based on the Health Belief Model. The current study was a randomised trial of 120 teachers over 40 years old in two groups receiving multimedia or group education, both based on the Health Belief Model. Participants completed questionnaires before, immediately and three months after educational intervention. Mammography was evaluated before and after educational intervention. The participants in the two groups were demographically similar. Comparison showed no difference noted in the scores of knowledge, perceived barriers, susceptibility, and severity constructs between two groups (p > 0.05). Health motivation and benefit were perceived to be higher in the group education compared to the multimedia group. There was a significant difference in mammography between two groups after the intervention (p= 0.003). Planning and implementation of educational program based on the Health Belief Model can raise knowledge and increase participation in mammography especially with group education.

  17. Quality-control design for surface-water sampling in the National Water-Quality Network

    USGS Publications Warehouse

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  18. Dissemination of periodic mammography and patterns of use, by birth cohort, in Catalonia (Spain)

    PubMed Central

    Rue, Montserrat; Carles, Misericordia; Vilaprinyo, Ester; Martinez-Alonso, Montserrat; Espinas, Josep-Alfons; Pla, Roger; Brugulat, Pilar

    2008-01-01

    Background In Catalonia (Spain) breast cancer mortality has declined since the beginning of the 1990s. The dissemination of early detection by mammography and the introduction of adjuvant treatments are among the possible causes of this decrease, and both were almost coincident in time. Thus, understanding how these procedures were incorporated into use in the general population and in women diagnosed with breast cancer is very important for assessing their contribution to the reduction in breast cancer mortality. In this work we have modeled the dissemination of periodic mammography and described repeat mammography behavior in Catalonia from 1975 to 2006. Methods Cross-sectional data from three Catalan Health Surveys for the calendar years 1994, 2002 and 2006 was used. The dissemination of mammography by birth cohort was modeled using a mixed effects model and repeat mammography behavior was described by age and survey year. Results For women born from 1938 to 1952, mammography clearly had a period effect, meaning that they started to have periodic mammograms at the same calendar years but at different ages. The age at which approximately 50% of the women were receiving periodic mammograms went from 57.8 years of age for women born in 1938–1942 to 37.3 years of age for women born in 1963–1967. Women in all age groups experienced an increase in periodic mammography use over time, although women in the 50–69 age group have experienced the highest increase. Currently, the target population of the Catalan Breast Cancer Screening Program, 50–69 years of age, is the group that self-reports the highest utilization of periodic mammograms, followed by the 40–49 age group. A higher proportion of women of all age groups have annual mammograms rather than biennial or irregular ones. Conclusion Mammography in Catalonia became more widely implemented during the 1990s. We estimated when cohorts initiated periodic mammograms and how frequently women are receiving them

  19. ‘It’s Easier Said Than Done’: Perspectives on Mammography From Women With Intellectual Disabilities

    PubMed Central

    Wilkinson, Joanne E.; Deis, Cristina E.; Bowen, Deborah J.; Bokhour, Barbara G.

    2011-01-01

    PURPOSE Women with intellectual disabilities (or mental retardation) are living longer, receiving primary care in the community, and have equal rates of breast cancer compared with women in the general population, but they have lower rates of mammography. Although several public campaigns have successfully raised the mammography rate for racial and ethnic minority women, they have not penetrated the community of women with intellectual disabilities. No research to date has explored potential barriers to mammography for these women by involving the women themselves as participants. METHODS We undertook a qualitative study to explore the perceptions and understanding of mammography for women with intellectual disabilities and some of the potential reasons they would or would not have the test. Twenty-seven intellectually disabled women were recruited through a variety of community groups and interviewed using a semistructured interview guide. Data were analyzed using qualitative techniques from grounded theory. RESULTS Participants in this study described being poorly prepared for mammography: they did not understand its purpose and were not prepared for the logistics of the experience. The latter was more upsetting to participants and contributed to their negative perceptions of mammography. Participants reported feeling unprepared and singled out for being unprepared, despite their desire to have at least 1 mammogram, as do other women their age. CONCLUSIONS Women with intellectual disabilities perceive mammography differently than do women who do not have intellectual disabilities, and their perception is informed by inadequate knowledge, anxiety, and inadequate preparation. These themes should be considered when planning cancer prevention interventions with this population and when counseling individual women in the clinical setting. PMID:21403141

  20. Mammography Adherence in African-American Women: Results of a Randomized Controlled Trial.

    PubMed

    Gathirua-Mwangi, Wambui G; Monahan, Patrick O; Stump, Timothy; Rawl, Susan M; Skinner, Celette Sugg; Champion, Victoria L

    2016-02-01

    Breast cancer is the second leading cause of cancer mortality among women in the developed world. Mammography screening is especially important for African-Americans because they experience a greater mortality (OR = 1.38) than Caucasians despite having a lower incidence of breast cancer. The purpose of this study was to compare the effects of two interventions with usual care on mammography adherence among African-American women. A subsample of African-American women (n = 244) aged 41-65 years who had not had a mammogram in the last 15 months and no history of breast cancer was randomly assigned to receive (1) mailed interactive DVD, (2) computer-tailored telephone counseling, or (3) usual care. The DVD intervention was five times more effective than usual care for promoting mammography screening at 6 months follow-up among women who earned less than $30,000 (OR = 5.3). Compared to usual care, neither the DVD nor phone produced significant effects for women with household incomes >$30,000. Use of a mailed DVD for low-income African-American women may be an effective way to increase mammography adherence.

  1. Pictorial essay: Mammography of the male breast

    PubMed Central

    Popli, Manju Bala; Popli, V; Bahl, P; Solanki, Y

    2009-01-01

    Mammography is an imaging modality that is widely perceived to be of use only in women for the detection and diagnosis of breast pathologies. Here, we present a pictorial essay on the mammographic spectrum of male breast pathologies. PMID:19881102

  2. Feasibility study of a TIMEPIX detector for mammography applications

    NASA Astrophysics Data System (ADS)

    Ávila, Carlos A.; Mendoza, Luis M.; Roque, Gerardo A.; Loaiza, Leonardo; Racedo, Jorge; Rueda, Roberto

    2017-11-01

    We present a comparison study of two X-ray systems for mammography imaging. One is a SELENIA clinical system and the second is a TIMEPIX based system. The aim of the study is to determine the capability of a TIMEPIX detector for mammography applications. We first compare signal to noise ratio (SNR) of X-ray images of Al2O3 spheres with diameters of 0.16mm, 0.24mm and 0.32mm, of a commercial mammography accreditation phantom CIRS015, obtained with each system. Then, we make a similar comparison for a second phantom built with Hydroxyapatite crystals with different morphology and sizes ranging between 0.15mm and 0.83mm, which are embedded within the same block of PMMA of the CIRS015 phantom. Our study allows us to determine the minimum size of Al2O3 spheres on the order of 240μm, with 33% lower SNR for the TIMEPIX system as compared to the SELENIA system. When comparing the images of Hydroxyapatite crystals from both systems, the minimum size observed is about 300μm, with 23% lower SNR for TIMEPIX.

  3. Image segmentation and 3D visualization for MRI mammography

    NASA Astrophysics Data System (ADS)

    Li, Lihua; Chu, Yong; Salem, Angela F.; Clark, Robert A.

    2002-05-01

    MRI mammography has a number of advantages, including the tomographic, and therefore three-dimensional (3-D) nature, of the images. It allows the application of MRI mammography to breasts with dense tissue, post operative scarring, and silicon implants. However, due to the vast quantity of images and subtlety of difference in MR sequence, there is a need for reliable computer diagnosis to reduce the radiologist's workload. The purpose of this work was to develop automatic breast/tissue segmentation and visualization algorithms to aid physicians in detecting and observing abnormalities in breast. Two segmentation algorithms were developed: one for breast segmentation, the other for glandular tissue segmentation. In breast segmentation, the MRI image is first segmented using an adaptive growing clustering method. Two tracing algorithms were then developed to refine the breast air and chest wall boundaries of breast. The glandular tissue segmentation was performed using an adaptive thresholding method, in which the threshold value was spatially adaptive using a sliding window. The 3D visualization of the segmented 2D slices of MRI mammography was implemented under IDL environment. The breast and glandular tissue rendering, slicing and animation were displayed.

  4. Time to harmonize national ambient air quality standards.

    PubMed

    Kutlar Joss, Meltem; Eeftens, Marloes; Gintowt, Emily; Kappeler, Ron; Künzli, Nino

    2017-05-01

    The World Health Organization has developed ambient air quality guidelines at levels considered to be safe or of acceptable risk for human health. These guidelines are meant to support governments in defining national standards. It is unclear how they are followed. We compiled an inventory of ambient air quality standards for 194 countries worldwide for six air pollutants: PM 2.5 , PM 10 , ozone, nitrogen dioxide, sulphur dioxide and carbon monoxide. We conducted literature and internet searches and asked country representatives about national ambient air quality standards. We found information on 170 countries including 57 countries that did not set any air quality standards. Levels varied greatly by country and by pollutant. Ambient air quality standards for PM 2.5 , PM 10 and SO 2 poorly complied with WHO guideline values. The agreement was higher for CO, SO 2 (10-min averaging time) and NO 2 . Regulatory differences mirror the differences in air quality and the related burden of disease around the globe. Governments worldwide should adopt science based air quality standards and clean air management plans to continuously improve air quality locally, nationally, and globally.

  5. Using automatically extracted information from mammography reports for decision-support

    PubMed Central

    Bozkurt, Selen; Gimenez, Francisco; Burnside, Elizabeth S.; Gulkesen, Kemal H.; Rubin, Daniel L.

    2016-01-01

    Objective To evaluate a system we developed that connects natural language processing (NLP) for information extraction from narrative text mammography reports with a Bayesian network for decision-support about breast cancer diagnosis. The ultimate goal of this system is to provide decision support as part of the workflow of producing the radiology report. Materials and methods We built a system that uses an NLP information extraction system (which extract BI-RADS descriptors and clinical information from mammography reports) to provide the necessary inputs to a Bayesian network (BN) decision support system (DSS) that estimates lesion malignancy from BI-RADS descriptors. We used this integrated system to predict diagnosis of breast cancer from radiology text reports and evaluated it with a reference standard of 300 mammography reports. We collected two different outputs from the DSS: (1) the probability of malignancy and (2) the BI-RADS final assessment category. Since NLP may produce imperfect inputs to the DSS, we compared the difference between using perfect (“reference standard”) structured inputs to the DSS (“RS-DSS”) vs NLP-derived inputs (“NLP-DSS”) on the output of the DSS using the concordance correlation coefficient. We measured the classification accuracy of the BI-RADS final assessment category when using NLP-DSS, compared with the ground truth category established by the radiologist. Results The NLP-DSS and RS-DSS had closely matched probabilities, with a mean paired difference of 0.004 ± 0.025. The concordance correlation of these paired measures was 0.95. The accuracy of the NLP-DSS to predict the correct BI-RADS final assessment category was 97.58%. Conclusion The accuracy of the information extracted from mammography reports using the NLP system was sufficient to provide accurate DSS results. We believe our system could ultimately reduce the variation in practice in mammography related to assessment of malignant lesions and improve

  6. Screening Ultrasound as an Adjunct to Mammography in Women with Mammographically Dense Breasts

    PubMed Central

    Scheel, John R.; Lee, Janie M.; Sprague, Brian L.; Lee, Christoph I.; Lehman, Constance D.

    2015-01-01

    There is increasing interest in the potential benefits and harms of screening ultrasound to supplement mammographic screening of women with dense breast tissue. We review the current evidence regarding adjunctive screening breast ultrasound (US) and provide a summary for clinicians who counsel patients with dense breasts. We conducted a comprehensive literature review of published clinical trials and observational cohort studies assessing the efficacy of screening handheld US (HHUS) and automated breast US (ABUS) to supplement mammography among women with dense breasts. From a total of 189 peer-reviewed publications on the performance of screening US, 12 studies were relevant to our analysis. The reporting of breast cancer risk factors varied across studies; however, the study populations tended to be at greater than average risk for developing breast cancer. There is consistent evidence that adjunctive screening US detects more invasive cancers compared to mammography alone, but there is currently no evidence of associated long-term breast cancer mortality reduction. The studies also collectively found that US was associated with an additional 11.7–106.6 biopsies/1,000 examinations (Median 52.2), and detected an additional 0.3–7.7 cancers/1,000 examinations (Median 4.2). The associated number of unnecessary breast biopsies resulting from adjunct US screening exceeds that observed with screening mammography alone by approximately 5-fold. Adjunctive screening with ultrasound should also be considered in the context of screening mammography. It is important for clinicians to be aware that improvements in cancer detection in mammographically dense breasts have been achieved with the transition from film to digital mammography, reducing a limitation of film mammography. Clinicians should discuss breast density as one of several important breast cancer risk factors, consider the potential harms of adjunctive screening, and arrive at a shared decision consistent with

  7. National Water-Quality Assessment Program: Central Arizona Basins

    USGS Publications Warehouse

    Cordy, Gail E.

    1994-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status and trends in the quality of a large, representative part of the Nation's surface-water and ground-water resources and to provide a sound, scientific understanding of the primary natural and human factors affecting the quality of these resources. In meeting these goals, the program will produce a wealth of water-quality information that will be useful to policymakers and managers at the National, State, and local levels. Studies of 60 hydrologic systems that include parts of most major river basins and aquifer systems (study-unit investigations) are the building blocks of the national assessment. The 60 study units range in size from 1,000 to about 60,000 mi2 and represent 60 to 70 percent of the Nation's water use and population served by public water supplies. Twenty study-unit investigations were started in 1991, 20 additional studies started in 1994, and 20 more are planned to start in 1997. The Central Arizona Basins study unit began assessment activities in 1994.

  8. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    PubMed

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  9. [What kind of information do German health information pamphlets provide on mammography screening?].

    PubMed

    Kurzenhäuser, Stephanie

    2003-02-01

    To make an informed decision on participation in mammography screening, women have to be educated about all the risks and benefits of the procedure in a manner that is detailed and understandable. But an analysis of 27 German health pamphlets on mammography screening shows that many relevant pieces of information about the benefits, the risks, and especially the meaning of screening results are only insufficiently communicated. Many statements were presented narratively rather than as precise statistics. Depending on content, 17 to 62% of the quantifiable statements were actually given as numerical data. To provide comprehensive information and to avoid misunderstandings, it is necessary to supplement the currently available health pamphlets and make the information on mammography screening more precise.

  10. Quality and Safety in Health Care, Part XVII: The ACS National Surgical Quality Improvement Program.

    PubMed

    Harolds, Jay A

    2016-12-01

    Mainly due to the positive effect on quality and safety from the Veterans Health Administration National Surgical Quality Improvement Program (VASQIP), a National Surgical Quality Improvement Program (NSQIP) for private hospitals was begun, which is now under the auspices of the American College of Surgeons (ACS). More than 600 hospitals now participate in the ACS-NSQIP. The information gained by the institutions is typically utilized to initiate quality improvement activities. The ACS-NSQIP also shares information on how to get better results, has national meetings, and provides other support.

  11. Informed decision making before initiating screening mammography: does it occur and does it make a difference?

    PubMed

    Nekhlyudov, Larissa; Li, Rong; Fletcher, Suzanne W

    2008-12-01

    Informed decision making regarding screening mammography is recommended for women under age 50. To what extent it occurs in clinical settings is unclear. Using a mailed instrument, we surveyed women aged 40-44 prior to their first screening mammogram. All women were members of a large health maintenance organization and received care at a large medical practice in the Greater Boston area. The survey measured informed decision making, decisional conflict, satisfaction, and screening mammography knowledge and intentions to undergo screening. Ninety-six women responded to the survey (response rate 47%). Overall, women reported limited informed decision making regarding screening mammography, both with respect to information exchange and involvement in the decision process. Less than half (47%) reported discussing the benefits of screening; 23% the uncertainties; and only 7% the harms. About 30% reported discussing the nature of the decision or clinical issue; and 29% reported their provider elicited their preferred role in the decision; 38% their preferences; and 24% their understanding of the information. Women who were uninformed had higher decisional conflict (2.37 vs. 1.83, P=0.005) about screening mammography and were more likely to be dissatisfied with the information and involvement. Women's screening mammography knowledge was limited in most areas; however being presented with information did not diminish their intentions to undergo screening. Informed decision making before initiating screening mammography is limited in this setting. There appears to be little indication that information about the benefits and harms decreases women's intentions to undergo screening. Methods to communicate information to women before initiating screening mammography are needed.

  12. Utilization of screening mammography in New Hampshire: a population-based assessment.

    PubMed

    Carney, Patricia A; Goodrich, Martha E; Mackenzie, Todd; Weiss, Julia E; Poplack, Steven P; Wells, Wendy S; Titus-Ernstoff, Linda

    2005-10-15

    The objective of screening mammography is to identify breast carcinoma early, which requires routine screening. Although self-report data indicate that screening utilization is high, the results of this population-based assessment indicated that utilization is lower than reported previously. The authors compared New Hampshire population data from the 2000 Census with clinical encounter data for the corresponding time obtained from the New Hampshire Mammography Network, a mammography registry that captures approximately 90% of the mammograms performed in participating New Hampshire facilities. The results showed that approximately 36% of New Hampshire women either never had a mammogram or had not had a mammogram in > 27 months (irregular screenees), and older women (80 yrs and older) were less likely to be screened (79% unscreened/underscreened) compared with younger women (ages 40-69 yrs; 28-32% unscreened/underscreened). Of the screened women, 44% were adhering to an interval of 14 months, and 21% were adhering within 15 months and 26 months. The remaining 35% of the women had 1 or 2 mammograms and did not return within 27 months. Routine mammography screening may be occurring less often than believed when survey data alone are used. An important, compelling concern is the reason women had one or two mammograms only and then did not return for additional screening. This area deserves additional research. Copyright 2005 American Cancer Society

  13. Baptist Memorial Hospital for Women: quality lifelines for a lifetime.

    PubMed

    Beard, Cindy; Lilly, Kristen; Poynter, Joni; Thetford, Carol; Thompson, Rosalee; Vaughn, Anita

    2006-10-01

    At Baptist Women's, a not-for-profit, 140-bed free-standing hospital, the Institute of Medicine's six quality dimensions are embedded into the quality blueprint and strategic plan. Quality initiatives and dashboards are shared through an established shared drive, which is accessible for all employees, to track performance on identified dashboards. IMPROVING MAMMOGRAPHY CYCLE TIME AT THE WOMEN'S HEALTH CENTER: Cycle time (arrival to departure) for mammography was identified as the top improvement priority. Increasing the percentage of patients who had preregistered reduced admission time, and process changes were made to move the patient through the center more efficiently. For example, patients with orders for additional films were flagged to ensure that these exams were completed before a new patient's exam. The ultrasound schedule was blocked during peak times to ensure that add-on exams could be performed in a timely manner. The cycle time was reduced for screening mammography (from 2 hours in 2003 to 30 minutes in April 2006) and diagnostic screenings, including review of films and reports with radiologist at departure, decreased from > 3 hours in 2003 to 2.5 hours in April 2006. Expectations of teamwork, proactive problem resolution, communication on all levels, and customer service are the cornerstone of Baptist Women's culture of quality.

  14. Mammography status using patient self-reports and computerized radiology database.

    PubMed

    Thompson, B; Taylor, V; Goldberg, H; Mullen, M

    1999-10-01

    This study sought to compare self-reported mammography use of low-income women utilizing an inner-city public hospital with a computerized hospital database for tracking mammography use. A survey of all age-eligible women using the hospital's internal medicine clinic was done; responses were matched with the radiology database. We examined concordance among the two data sources. Concordance between self-report and the database was high (82%) when using "ever had a mammogram at the hospital," but low (58%) when comparing self-reported last mammogram with the information contained in the database. Disagreements existed between self-reports and the database. Because we sought to ensure that women would know exactly what a mammogram entailed by including a picture of a woman having a mammogram, it is possible that women's responses were accurate, leading to concerns that discrepancies might be present in the database. Physicians and staff must ensure that they understand the full history of a woman's experience with mammography before recommending for or against the procedure.

  15. Mammography screening credit card and compliance.

    PubMed

    Schapira, D V; Kumar, N B; Clark, R A; Yag, C

    1992-07-15

    Screening for breast cancer using mammography has been shown to be effective in reducing mortality from breast cancer. The authors attempted to determine if use of a wallet-size plastic screening "credit" card would increase participants' compliance for subsequent mammograms when compared with traditional methods of increasing compliance. Two hundred and twenty consecutive women, ages 40-70 years, undergoing their first screening mammography were recruited and assigned randomly to four groups receiving (1) a reminder plastic credit card (2) reminder credit card with written reminder; (3) appointment card; and (4) verbal recommendation. Return rates of the four groups were determined after 15 months. The return rate for subsequent mammograms was significantly higher for participants (72.4%) using the credit card than for participants (39.8%) exposed to traditional encouragement/reminders (P less than 0.0001). The credit card was designed to show the participant's screening anniversary, and the durability of the card may have been a factor in increasing the return rate. The use of reminder credit cards may increase compliance for periodic screening examinations for other cancers and other chronic diseases.

  16. What Do Patients Want to Know? Questions and Concerns Regarding Mammography Expressed Through Social Media.

    PubMed

    Charlie, Abbas M; Gao, Yiming; Heller, Samantha L

    2017-12-05

    The purpose of this project is to identify questions and concerns patients have regarding breast cancer screening mammography to establish priorities in patient education and health care communication. A content analysis of posted questions (June 2010 to February 2017) containing the keywords mammogram and mammography was conducted on the social media question and answer website Quora (Quora Inc, Mountainview, California). Question topic, responses, and number of views were recorded. Comparisons were made by respondent type (medical professional or nonmedical professional) for screening recommendations and accompanying evidence. Descriptive statistics were employed to summarize the results. Overall, 197,620 views of mammography-related questions were identified, focused on 51 questions and 172 responses (51 of 172 [29.7%] by medical professionals [n = 25]; 121 of 172 [70.3%] by nonmedical professionals [n = 121]). Mammographic efficacy (16 of 51 [31.4%]) and screening guidelines (10 of 51 [19.6%]) were the most frequently queried topics. Overall, the majority of respondents were supportive of screening mammography. Most medical professionals recommended screening mammography starting at age 40, even after revisions in guidelines. Among nonmedical professionals, 4 of 22 (18.2%) were against screening mammography with less consensus regarding appropriate age of initial screen. Health society websites and journal articles were the most commonly referenced sources among medical and nonmedical professionals, respectively. A considerable interest in screening mammography guidelines and mammographic efficacy exists among users who seek health information on a social media question and answer website. Awareness of such platforms allows a unique opportunity for targeted health education and dissemination of accurate information, which may be able to reach a potentially untapped or hard-to-reach patient population. Copyright © 2017 American College of Radiology

  17. Variation in false-positive rates of mammography reading among 1067 radiologists: a population-based assessment.

    PubMed

    Tan, Alai; Freeman, Daniel H; Goodwin, James S; Freeman, Jean L

    2006-12-01

    The accuracy of mammography reading varies among radiologists. We conducted a population-based assessment on radiologist variation in false- positive rates of screening mammography and its associated radiologist characteristics. About 27,394 screening mammograms interpreted by 1067 radiologists were identified from a 5% non-cancer sample of Medicare claims during 1998-1999. The data were linked to the American Medical Association Masterfile to obtain radiologist characteristics. Multilevel logistic regression models were used to examine the radiologist variation in false-positive rates of screening mammography and the associated radiologist characteristics. Radiologists varied substantially in the false-positive rates of screening mammography (ranging from 1.5 to 24.1%, adjusting for patient characteristics). A longer time period since graduation is associated with lower false-positive rates (odds ratio [OR] for every 10 years increase: 0.87, 95% Confidence Interval [CI], 0.81-0.94) and female radiologists had higher false-positive rates than male radiologists (OR = 1.25, 95% CI, 1.05-1.49), adjusting for patient and other radiologist characteristics. The unmeasured factors contributed to about 90% of the between-radiologist variance. Radiologists varied greatly in accuracy of mammography reading. Female and more recently trained radiologists had higher false-positive rates. The variation among radiologists was largely due to unmeasured factors, especially unmeasured radiologist factors. If our results are confirmed in further studies, they suggest that system-level interventions would be required to reduce variation in mammography interpretation.

  18. Radiation-Induced Breast Cancer Incidence and Mortality from Digital Mammography Screening: A Modeling Study

    PubMed Central

    Miglioretti, Diana L.; Lange, Jane; van den Broek, Jeroen J.; Lee, Christoph I.; van Ravesteyn, Nicolien T.; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J.; Melnikow, Joy; de Koning, Harry J.; Hubbard, Rebecca A.

    2016-01-01

    Background Estimates of radiation-induced breast cancer risk from mammography screening have not previously considered dose exposure variation or diagnostic work-up after abnormal screening. Objective To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening, considering exposure from screening and diagnostic mammography and dose variation across women. Design Two simulation-modeling approaches using common data on screening mammography from the Breast Cancer Surveillance Consortium and radiation dose from mammography from the Digital Mammographic Imaging Screening Trial. Setting U.S. population. Patients Women aged 40–74 years. Interventions Annual or biennial digital mammography screening from age 40, 45, or 50 until 74. Measurements Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality per 100,000 women screened (harms). Results On average, annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancers (95% confidence interval [CI]=88–178) leading to 16 deaths (95% CI=11–23) relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 radiation-induced breast cancers leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete breast examination (8% of population) were projected to have higher radiation-induced breast cancer incidence and mortality (266 cancers, 35 deaths per 100,000 women), compared to women with small or average breasts (113 cancers, 15 deaths per 100,000 women). Biennial screening starting at age 50 reduced risk of radiation-induced cancers 5-fold. Limitations We were unable to estimate years of life lost from radiation-induced breast cancer. Conclusions Radiation-induced breast cancer incidence and mortality from digital mammography screening are impacted by dose

  19. Mammography with and without radiolucent positioning sheets: Comparison of projected breast area, pain experience, radiation dose and technical image quality.

    PubMed

    Timmers, Janine; Voorde, Marloes Ten; Engen, Ruben E van; Landsveld-Verhoeven, Cary van; Pijnappel, Ruud; Greve, Kitty Droogh-de; Heeten, Gerard J den; Broeders, Mireille J M

    2015-10-01

    To compare projected breast area, image quality, pain experience and radiation dose between mammography performed with and without radiolucent positioning sheets. 184 women screened in the Dutch breast screening programme (May-June 2012) provided written informed consent to have one additional image taken with positioning sheets. 5 cases were excluded (missing data). Pain was scored using the Numeric Rating Scale. Radiation dose was estimated using the Dance model and projected breast area using computer software. Two radiologists and two radiographers assessed image quality. With positioning sheets significantly more pectoral muscle, lateral and medial breast tissue was projected (CC-views) and more and deeper depicted pectoral muscle (MLO-views). In contrast, visibility of white and darker areas was better on images without positioning sheets, radiologists were therefore better able to detect abnormalities (MLO-views). Women experienced more pain with positioning sheets (MLO-views only, mean difference NRS 0.98; SD 1.71; p=0,00). Mammograms with positioning sheets showed more breast tissue. Increased breast thickness after compression with sheets resulted in less visibility of white and darker areas and thus reduced detection of abnormalities. Also, women experienced more pain (MLO-views) due to the sheet material. A practical consideration is the fact that more subcutaneous fat tissue and skin are being pulled forward leading to folds in the nipple area. On balance, improvement to the current design is required before implementation in screening practice can be considered. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Comparison of radiologist performance with photon-counting full-field digital mammography to conventional full-field digital mammography.

    PubMed

    Cole, Elodia B; Toledano, Alicia Y; Lundqvist, Mats; Pisano, Etta D

    2012-08-01

    The purpose of this study was to assess the performance of a MicroDose photon-counting full-field digital mammography (PCM) system in comparison to full-field digital mammography (FFDM) for area under the receiver-operating characteristic (ROC) curve (AUC), sensitivity, specificity, and feature analysis of standard-view mammography for women presenting for screening mammography, diagnostic mammography, or breast biopsy. A total of 133 women were enrolled in this study at two European medical centers, with 67 women who had a pre-existing 10-36 months FFDM enrolled prospectively into the study and 66 women who underwent breast biopsy and had screening PCM and diagnostic FFDM, including standard craniocaudal and mediolateral oblique views of the breast with the lesion, enrolled retrospectively. The case mix consisted of 49 cancers, 17 biopsy-benign cases, and 67 normal cases. Sixteen radiologists participated in the reader study and interpreted all 133 cases in both conditions, separated by washout period of ≥4 weeks. ROC curve and free-response ROC curve analyses were performed for noninferiority of PCM compared to FFDM using a noninferiority margin Δ value of 0.10. Feature analysis of the 66 cases with lesions was conducted with all 16 readers at the conclusion of the blinded reads. Mean glandular dose was recorded for all cases. The AUC for PCM was 0.947 (95% confidence interval [CI], 0.920-0.974) and for FFDM was 0.931 (95% CI, 0.898-0.964). Sensitivity per case for PCM was 0.936 (95% CI, 0.897-0.976) and for FFDM was 0.908 (95% CI, 0.856-0.960). Specificity per case for PCM was 0.764 (95% CI, 0.688-0.841) and for FFDM was 0.749 (95% CI, 0.668-0.830). Free-response ROC curve figures of merit were 0.920 (95% CI, 0.881-0.959) and 0.903 (95% CI, 0.858-0.948) for PCM and FFDM, respectively. Sensitivity per lesion was 0.903 (95% CI, 0.846-0.960) and 0.883 (95% CI, 0.823-0.944) for PCM and FFDM, respectively. The average false-positive marks per image of noncancer

  1. Needs assessment for next generation computer-aided mammography reference image databases and evaluation studies.

    PubMed

    Horsch, Alexander; Hapfelmeier, Alexander; Elter, Matthias

    2011-11-01

    Breast cancer is globally a major threat for women's health. Screening and adequate follow-up can significantly reduce the mortality from breast cancer. Human second reading of screening mammograms can increase breast cancer detection rates, whereas this has not been proven for current computer-aided detection systems as "second reader". Critical factors include the detection accuracy of the systems and the screening experience and training of the radiologist with the system. When assessing the performance of systems and system components, the choice of evaluation methods is particularly critical. Core assets herein are reference image databases and statistical methods. We have analyzed characteristics and usage of the currently largest publicly available mammography database, the Digital Database for Screening Mammography (DDSM) from the University of South Florida, in literature indexed in Medline, IEEE Xplore, SpringerLink, and SPIE, with respect to type of computer-aided diagnosis (CAD) (detection, CADe, or diagnostics, CADx), selection of database subsets, choice of evaluation method, and quality of descriptions. 59 publications presenting 106 evaluation studies met our selection criteria. In 54 studies (50.9%), the selection of test items (cases, images, regions of interest) extracted from the DDSM was not reproducible. Only 2 CADx studies, not any CADe studies, used the entire DDSM. The number of test items varies from 100 to 6000. Different statistical evaluation methods are chosen. Most common are train/test (34.9% of the studies), leave-one-out (23.6%), and N-fold cross-validation (18.9%). Database-related terminology tends to be imprecise or ambiguous, especially regarding the term "case". Overall, both the use of the DDSM as data source for evaluation of mammography CAD systems, and the application of statistical evaluation methods were found highly diverse. Results reported from different studies are therefore hardly comparable. Drawbacks of the DDSM

  2. The Efficacy of Mammography Boot Camp to Improve the Performance of Radiologists

    PubMed Central

    Lee, Eun Hye; Jung, Seung Eun; Kim, You Me; Choi, Nami

    2014-01-01

    Objective To evaluate the efficacy of a mammography boot camp (MBC) to improve radiologists' performance in interpreting mammograms in the National Cancer Screening Program (NCSP) in Korea. Materials and Methods Between January and July of 2013, 141 radiologists were invited to a 3-day educational program composed of lectures and group practice readings using 250 digital mammography cases. The radiologists' performance in interpreting mammograms were evaluated using a pre- and post-camp test set of 25 cases validated prior to the camp by experienced breast radiologists. Factors affecting the radiologists' performance, including age, type of attending institution, and type of test set cases, were analyzed. Results The average scores of the pre- and post-camp tests were 56.0 ± 12.2 and 78.3 ± 9.2, respectively (p < 0.001). The post-camp test scores were higher than the pre-camp test scores for all age groups and all types of attending institutions (p < 0.001). The rate of incorrect answers in the post-camp test decreased compared to the pre-camp test for all suspicious cases, but not for negative cases (p > 0.05). Conclusion The MBC improves radiologists' performance in interpreting mammograms irrespective of age and type of attending institution. Improved interpretation is observed for suspicious cases, but not for negative cases. PMID:25246818

  3. Evolution of mammographic image quality in the state of Rio de Janeiro*

    PubMed Central

    Villar, Vanessa Cristina Felippe Lopes; Seta, Marismary Horsth De; de Andrade, Carla Lourenço Tavares; Delamarque, Elizabete Vianna; de Azevedo, Ana Cecília Pedrosa

    2015-01-01

    Objective To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. Materials and Methods Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval. Results Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%). Conclusion The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval. PMID:25987749

  4. Finding the minimal intervention needed for sustained mammography adherence.

    PubMed

    Gierisch, Jennifer M; DeFrank, Jessica T; Bowling, J Michael; Rimer, Barbara K; Matuszewski, Jeanine M; Farrell, David; Skinner, Celette Sugg

    2010-10-01

    Regular adherence to mammography screening saves lives, yet few women receive regular mammograms. RCT. Participants were recruited through a state employee health plan. All were women aged 40-75 years and had recent mammograms prior to enrollment (n=3547). Data were collected from 2004 to 2009. Trial tested efficacy of a two-step adaptively-designed intervention to increase mammography adherence over 4 years. The first intervention step consisted of three reminder types: enhanced usual care reminders (EUCR); enhanced letter reminders (ELR); both delivered by mail, and automated telephone reminders (ATR). After delivery of reminders, women who became off-schedule in any of the 4 years received a second step of supplemental interventions. Three supplemental intervention arms contained priming letters and telephone counseling: barriers only (BarriCall); barriers plus positive consequences of getting mammograms (BarriConCall+); and barriers plus negative consequences of not getting mammograms (BarriConCall-). Average cumulative number of days non-adherent to mammography over 4 years based on annual screening guidelines (analyses conducted in 2009). All reminders performed equally well in reducing number of days of non-adherence. Women randomized to receive supplemental interventions had significantly fewer days of non-adherence compared to women who received EUCR (p=0.0003). BarrConCall+ and BarrConCall- conditions did not significantly differ in days non-adherent compared to women in the barriers-only condition (BarriCon). The minimal intervention needed for sustained mammography use is a combination of a reminder followed by a priming letter and barrier-specific telephone counseling for women who become off-schedule. Additional costs associated with supplemental interventions should be considered by organizations deciding which interventions to use. NCT01148875. Copyright © 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Effect of age on breast cancer screening using tomosynthesis in combination with digital mammography.

    PubMed

    Rafferty, Elizabeth A; Rose, Stephen L; Miller, Dave P; Durand, Melissa A; Conant, Emily F; Copit, Debra S; Friedewald, Sarah M; Plecha, Donna M; Ott, Ingrid L; Hayes, Mary K; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Niklason, Loren T

    2017-08-01

    To determine the effect of tomosynthesis imaging as a function of age for breast cancer screening. Screening performance metrics from 13 institutions were examined for 12 months prior to introduction of tomosynthesis (period 1) and compared to those after introduction of tomosynthesis (period 2, range 3-22 months). Screening metrics for women ages 40-49, 50-59, 60-69, and 70+ , included rates per 1000 screens for recalls, biopsies, cancers, and invasive cancers detected. Performance parameters were compared for women screened with digital mammography alone (n = 278,908) and digital mammography + tomosynthesis (n = 173,414). Addition of tomosynthesis to digital mammography produced significant reductions in recall rates for all age groups and significant increases in cancer detection rates for women 40-69. Largest recall rate reduction with tomosynthesis was for women 40-49, decreasing from 137 (95% CI 117-156) to 115 (95% CI 95-135); difference, -22 (95% CI -26 to -18; P < .001). Simultaneous increase in invasive cancer detection rate for women 40-49 from 1.6 (95% CI 1.2-1.9) to 2.7 (95% CI 2.2-3.1) with tomosynthesis (difference, 1.1; 95% CI 0.6-1.6; P < .001) was observed. Addition of tomosynthesis to digital mammography increased invasive cancer detection rates for women 40-69 and decreased recall rates for all age groups with largest performance gains seen in women 40-49. The similar performance seen with tomosynthesis screening for women in their 40s compared to digital mammography for women in their 50s argues strongly for commencement of mammography screening at age 40 using tomosynthesis.

  6. Solid-state dosimeters: A new approach for mammography measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brateman, Libby F., E-mail: bratel@radiology.ufl.edu; Heintz, Philip H.

    2015-02-15

    Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-fieldmore » digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the

  7. [Malignant and benign diseases of the breast in 41 male patients: mammography, sonography and pathohistological correlations].

    PubMed

    Partik, B; Mallek, R; Rudas, M; Pokieser, P; Wunderbaldinger, P; Helbich, T H

    2001-11-01

    The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS(R) classification. Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92 %, 89 %, 80 %, 96 % and 90 %, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2 % (2/11) of suspicious lesions. In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence.

  8. Do physician communication skills influence screening mammography utilization?

    PubMed

    Meguerditchian, Ari-Nareg; Dauphinee, Dale; Girard, Nadyne; Eguale, Tewodros; Riedel, Kristen; Jacques, André; Meterissian, Sarkis; Buckeridge, David L; Abrahamowicz, Michal; Tamblyn, Robyn

    2012-07-25

    The quality of physician communication skills influences health-related decisions, including use of cancer screening tests. We assessed whether patient-physician communication examination scores in a national, standardized clinical skills examination predicted future use of screening mammography (SM). Cohort study of 413 physicians taking the Medical Council of Canada clinical skills examination between 1993 and 1996, with follow up until 2006. Administrative claims for SM performed within 12 months of a comprehensive health maintenance visit for women 50-69 years old were reviewed. Multivariable regression was used to estimate the relationship between physician communication skills exam score and patients' SM use while controlling for other factors. Overall, 33.8 % of 96,708 eligible women who visited study physicians between 1993 and 2006 had an SM in the 12 months following an index visit. Patient-related factors associated with increased SM use included higher income, non-urban residence, low Charlson co-morbidity index, prior benign breast biopsy and an interval >12 months since the previous mammogram. Physician-related factors associated with increased use of SM included female sex, surgical specialty, and higher communication skills score. After adjusting for physician and patient-related factors, the odds of SM increased by 24 % for 2SD increase in communication score (OR: 1.24, 95 % CI: 1.11 - 1.38). This impact was even greater in urban areas (OR 1.30, 95 % CI: 1.16, 1.46) and did not vary with practice experience (interaction p-value 0.74). Physicians with better communication skills documented by a standardized licensing examination were more successful at obtaining SM for their patients.

  9. Religious beliefs and mammography intention: findings from a qualitative study of a diverse group of American Muslim women.

    PubMed

    Padela, Aasim I; Vu, Milkie; Muhammad, Hadiyah; Marfani, Farha; Mallick, Saleha; Peek, Monica; Quinn, Michael T

    2016-10-01

    Studies suggest that American Muslim women underutilize mammography. While religion has a strong influence upon Muslim health behaviors, scant research has examined how religion-related beliefs inform Muslim women's intention for mammography. Our study identifies and examines such beliefs. Muslim women aged 40 years and older sampled from mosques participated in focus groups and individual interviews. Drawing upon the theory of planned behavior, interviews elicited salient behavioral, normative, and control beliefs regarding mammography and the influence of Islam upon screening intention. Fifty women participated in 6 focus groups and 19 in semistructured interviews, with near-equal numbers of African American, South Asian, and Arab Muslims. Forty-two percent of participants had not had a mammogram within the past 2 years. Across differences in race/ethnicity and mammography status, women voiced four religion-related salient beliefs that inform mammography intention: (1) the perceived duty to care for one's health, (2) religious practices as methods of disease prevention, (3) fatalistic notions about health, and (4) comfort with gender concordant health care. Religious beliefs influence decisions to pursue mammography across the ethnic/racial diversity of Muslim women. Notions about duty to God and the stewardship of one's body appear to enhance mammography intention. Theocentric notions of cure and illness and varied views regarding personal agency also inform decisional frames that impact mammography intention. Given the salience of religion among our participants, religiously tailored messages in interventions have the potential to enhance cancer screening. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Religious Beliefs and Mammography Intention: Findings from a Qualitative Study of a Diverse Group of American Muslim Women

    PubMed Central

    Padela, Aasim I.; Vu, Milkie; Muhammad, Hadiyah; Marfani, Farha; Mallick, Saleha; Peek, Monica; Quinn, Michael T.

    2017-01-01

    Objective Studies suggest that American Muslim women underutilize mammography. While religion has a strong influence upon Muslim health behaviors scant research has examined how religion-related beliefs inform Muslim women’s intention for mammography. Our study identifies and examines such beliefs. Methods Muslim women aged 40 and older sampled from mosques participated in focus groups and individual interviews. Drawing upon the Theory of Planned Behavior, interviews elicited salient behavioral, normative, and control beliefs regarding mammography and the influence of Islam upon screening intention. Results Fifty women participated in 6 focus groups and 19 in semi-structured interviews, with near-equal numbers of African American, South Asian, and Arab Muslims. Forty-two percent of participants had not had a mammogram within the past two years. Across differences in race/ethnicity and mammography status women voiced four religion-related salient beliefs that inform mammography intention: (1) the perceived duty to care for one’s health, (2) religious practices as methods of disease prevention, (3) fatalistic notions about health, and (4) comfort with gender concordant healthcare. Conclusions Religious beliefs influence decisions to pursue mammography across the ethnic/racial diversity of Muslim women. Notions about duty to God and the stewardship of one’s body appear to enhance mammography intention. Theocentric notions of cure and illness and varied views regarding personal agency also inform decisional frames that impact mammography intention. Given the salience of religion among our participants, religiously-tailored messages in interventions have the potential to enhance cancer screening. PMID:27424488

  11. Selective photon counter for digital x-ray mammography tomosynthesis

    NASA Astrophysics Data System (ADS)

    Goldan, Amir H.; Karim, Karim S.; Rowlands, J. A.

    2006-03-01

    Photon counting is an emerging detection technique that is promising for mammography tomosynthesis imagers. In photon counting systems, the value of each image pixel is equal to the number of photons that interact with the detector. In this research, we introduce the design and implementation of a low noise, novel selective photon counting pixel for digital mammography tomosynthesis in crystalline silicon CMOS (complementary metal oxide semiconductor) 0.18 micron technology. The design comprises of a low noise charge amplifier (CA), two low offset voltage comparators, a decision-making unit (DMU), a mode selector, and a pseudo-random counter. Theoretical calculations and simulation results of linearity, gain, and noise of the photon counting pixel are presented.

  12. Characteristics of YouTubeTM Videos Related to Mammography.

    PubMed

    Basch, Corey H; Hillyer, Grace Clarke; MacDonald, Zerlina L; Reeves, Rachel; Basch, Charles E

    2015-12-01

    With a monthly total of more than one billion unique visitors, YouTube TM is one of the Internet's most visited websites and contributes to the growing amount of health-related information on the Internet. The purpose of this study was to analyze coverage of mammography screening in popular YouTube TM videos. A total of 173 videos were included in the analysis. Compared with professionally created videos, consumer-created videos had a significantly greater number of comments (>9 comments 38.0% for consumer vs. 11.8% for professional videos, p=<0.001). Videos created by professionals more often portrayed general mammography information (97.1 vs. 88.7%) compared to those created by consumers. The vast majority of videos presented general information (93.6%) related to mammography, and almost two thirds addressed preparing for the test. Less than 20% dealt with other types of examinations. Approximately 30% discussed pain associated with the examination (35.3%) and addressed issues of anxiety (32.4%) and fear (29.5%). Nearly half of the videos presented information about the test results (46.2%). Over 25% covered medical or family history. The majority did not pertain to a specific age group. Future research should focus on analyzing the accuracy of the information in the videos.

  13. High-speed large angle mammography tomosynthesis system

    NASA Astrophysics Data System (ADS)

    Eberhard, Jeffrey W.; Staudinger, Paul; Smolenski, Joe; Ding, Jason; Schmitz, Andrea; McCoy, Julie; Rumsey, Michael; Al-Khalidy, Abdulrahman; Ross, William; Landberg, Cynthia E.; Claus, Bernhard E. H.; Carson, Paul; Goodsitt, Mitchell; Chan, Heang-Ping; Roubidoux, Marilyn; Thomas, Jerry A.; Osland, Jacqueline

    2006-03-01

    A new mammography tomosynthesis prototype system that acquires 21 projection images over a 60 degree angular range in approximately 8 seconds has been developed and characterized. Fast imaging sequences are facilitated by a high power tube and generator for faster delivery of the x-ray exposure and a high speed detector read-out. An enhanced a-Si/CsI flat panel digital detector provides greater DQE at low exposure, enabling tomo image sequence acquisitions at total patient dose levels between 150% and 200% of the dose of a standard mammographic view. For clinical scenarios where a single MLO tomographic acquisition per breast may replace the standard CC and MLO views, total tomosynthesis breast dose is comparable to or below the dose in standard mammography. The system supports co-registered acquisition of x-ray tomosynthesis and 3-D ultrasound data sets by incorporating an ultrasound transducer scanning system that flips into position above the compression paddle for the ultrasound exam. Initial images acquired with the system are presented.

  14. BREAST: a novel method to improve the diagnostic efficacy of mammography

    NASA Astrophysics Data System (ADS)

    Brennan, P. C.; Tapia, K.; Ryan, J.; Lee, W.

    2013-03-01

    High quality breast imaging and accurate image assessment are critical to the early diagnoses, treatment and management of women with breast cancer. Breast Screen Reader Assessment Strategy (BREAST) provides a platform, accessible by researchers and clinicians world-wide, which will contain image data bases, algorithms to assess reader performance and on-line systems for image evaluation. The platform will contribute to the diagnostic efficacy of breast imaging in Australia and beyond on two fronts: reducing errors in mammography, and transforming our assessment of novel technologies and techniques. Mammography is the primary diagnostic tool for detecting breast cancer with over 800,000 women X-rayed each year in Australia, however, it fails to detect 30% of breast cancers with a number of missed cancers being visible on the image [1-6]. BREAST will monitor the mistakes, identify reasons for mammographic errors, and facilitate innovative solutions to reduce error rates. The BREAST platform has the potential to enable expert assessment of breast imaging innovations, anywhere in the world where experts or innovations are located. Currently, innovations are often being assessed by limited numbers of individuals who happen to be geographically located close to the innovation, resulting in equivocal studies with low statistical power. BREAST will transform this current paradigm by enabling large numbers of experts to assess any new method or technology using our embedded evaluation methods. We are confident that this world-first system will play an important part in the future efficacy of breast imaging.

  15. Good reasons to implement quality assurance in nationwide breast cancer screening programs in Croatia and Serbia: results from a pilot study.

    PubMed

    Ciraj-Bjelac, Olivera; Faj, Dario; Stimac, Damir; Kosutic, Dusko; Arandjic, Danijela; Brkic, Hrvoje

    2011-04-01

    The purpose of this study is to investigate the need for and the possible achievements of a comprehensive QA programme and to look at effects of simple corrective actions on image quality in Croatia and in Serbia. The paper focuses on activities related to the technical and radiological aspects of QA. The methodology consisted of two phases. The aim of the first phase was the initial assessment of mammography practice in terms of image quality, patient dose and equipment performance in selected number of mammography units in Croatia and Serbia. Subsequently, corrective actions were suggested and implemented. Then the same parameters were re-assessed. Most of the suggested corrective actions were simple, low-cost and possible to implement immediately, as these were related to working habits in mammography units, such as film processing and darkroom conditions. It has been demonstrated how simple quantitative assessment of image quality can be used for optimisation purposes. Analysis of image quality parameters as OD, gradient and contrast demonstrated general similarities between mammography practices in Croatia and Serbia. The applied methodology should be expanded to larger number of hospitals and applied on a regular basis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  16. Sustaining mammography screening among the medically underserved: a follow-up evaluation.

    PubMed

    Davis, Terry C; Arnold, Connie L; Bennett, Charles L; Wolf, Michael S; Liu, Dachao; Rademaker, Alfred

    2015-04-01

    Our previous three-arm comparative effectiveness intervention in community clinic patients who were not up-to-date with screening resulted in mammography rates over 50% in all arms. Our aim was to evaluate the effectiveness and cost-effectiveness of the three interventions on improving biennial screening rates among eligible patients. A three-arm quasi-experimental evaluation was conducted in eight community clinics from 2008 to 2011. Screening efforts included (1) enhanced care: Participants received an in-person recommendation from a research assistant (RA) in year 1, and clinics followed usual clinic protocol for scheduling screening mammograms; (2) education intervention: Participants received education and in-person recommendation from an RA in year 1, and clinics followed usual clinic protocol for scheduling mammograms; or (3) nurse support: A nurse manager provided in-person education and recommendation, scheduled mammograms, and followed up with phone support. In all arms, mammography was offered at no cost to uninsured patients. Of 624 eligible women, biennial mammography within 24-30 months of their previous test was performed for 11.0% of women in the enhanced-care arm, 7.1% in the education- intervention arm, and 48.0% in the nurse-support arm (p<0.0001). The incremental cost was $1,232 per additional woman undergoing screening with nurse support vs. enhanced care and $1,092 with nurse support vs. education. Biennial mammography screening rates were improved by providing nurse support but not with enhanced care or education. However, this approach was not cost-effective.

  17. Performance evaluation of a retrofit digital detector-based mammography system.

    PubMed

    Marshall, Nicholas W; van Ongeval, Chantal; Bosmans, Hilde

    2016-02-01

    A retrofit flat panel detector was integrated with a GE DMR+ analog mammography system and characterized using detective quantum efficiency (DQE). Technical system performance was evaluated using the European Guidelines protocol, followed by a limited evaluation of clinical image quality for 20 cases using image quality criteria in the European Guidelines. Optimal anode/filter selections were established using signal difference-to-noise ratio measurements. Only small differences in peak DQE were seen between the three anode/filter settings, with an average value of 0.53. For poly(methyl methacrylate) (PMMA) thicknesses above 60 mm, the Rh/Rh setting was the optimal anode/filter setting. The system required a mean glandular dose of 0.54 mGy at 30 kV Rh/Rh to reach the Acceptable gold thickness limit for 0.1 mm details. Imaging performance of the retrofit unit with the GE DMR+ is notably better than of powder based computed radiography systems and is comparable to current flat panel FFDM systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Use of a photoessay to teach low-income African American women about mammography.

    PubMed

    Paskett, E D; Tatum, C; Wilson, A; Dignan, M; Velez, R

    1996-01-01

    Although incidence rates of breast cancer are lower among African American women than white women, mortality rates among African American women are higher, especially for women of lower socioeconomic levels. Reasons for this situation include the lesser use of breast cancer screening examinations by low-income, primarily African American women, late stage of diagnosis, and delays in treatment. As part of community outreach and public health clinic inreach programs for the Forsyth County Cancer Screening Project, approximately 908 African American women who reside in low-income housing communities were targeted for educational efforts related to breast cancer screening. Early in the project, it was discovered that many of the women were unfamiliar with mammography and had very little awareness of how the entire examination was conducted. This low level of knowledge was particularly important because it was a barrier for obtaining regular mammography. A photoessay depicting the process of getting a mammogram was developed and used in community outreach efforts in three formats: in educational classes, as a display in the housing communities, and in physicians' offices. The acceptability of this photoessay to communicate knowledge of and reduce fears about mammography was assessed through evaluation surveys in interviews with a sample of 47 women from the target population. Overall, these women liked the photoessay and felt that it provided knowledge about mammography and reduced fears associated with anticipating mammography. Strategies such as this may be ideal to communicate important information about cancer prevention and control in low-literacy populations.

  19. Screening Mammography: Patient Perceptions and Preferences Regarding Communication of Estimated Breast Cancer Risk.

    PubMed

    Amornsiripanitch, Nita; Mangano, Mark; Niell, Bethany L

    2017-05-01

    Many models exist to estimate a woman's risk of development of breast cancer. At screening mammography, many imaging centers collect data required for these models to identify women who may benefit from supplemental screening and referral for cancer risk assessment. The purpose of this study was to discern perceptions and preferences of screening mammography patients regarding communication of estimated breast cancer risk. An anonymous survey was distributed to screening and surveillance mammography patients between April and June 2015. Survey questions were designed to assess patient preferences regarding the receipt and complexity of risk estimate communication, including hypothetical scenarios with and without > 20% estimated risk of breast cancer. The McNemar test and the Wilcoxon signed rank test were used with p ≤ 0.05 considered statistically significant. The survey was distributed to 1061 screening and surveillance mammography patients, and 503 patients responded (response rate, 47%). Although 86% (431/503) of patients expressed interest in learning their estimated risk, only 8% (38/503) had undergone formal risk assessment. The preferred method (241 respondents [26%]) of communication of risk < 20% was a mailed letter accompanying annual mammogram results. For risk > 20%, patients preferred oral communication and were 10-fold as likely to choose only oral communication (p < 0.000001). For risk < 20% and > 20%, patients preferred to learn their estimated risk in great detail (69% and 85%), although women were significantly more likely to choose greater detail for risk > 20% (p < 0.00001). Screening mammography patients expressed interest in learning their estimated risk of breast cancer regardless of their level of hypothetical risk.

  20. Contrast-enhanced spectral mammography based on a photon-counting detector: quantitative accuracy and radiation dose

    NASA Astrophysics Data System (ADS)

    Lee, Seungwan; Kang, Sooncheol; Eom, Jisoo

    2017-03-01

    Contrast-enhanced mammography has been used to demonstrate functional information about a breast tumor by injecting contrast agents. However, a conventional technique with a single exposure degrades the efficiency of tumor detection due to structure overlapping. Dual-energy techniques with energy-integrating detectors (EIDs) also cause an increase of radiation dose and an inaccuracy of material decomposition due to the limitations of EIDs. On the other hands, spectral mammography with photon-counting detectors (PCDs) is able to resolve the issues induced by the conventional technique and EIDs using their energy-discrimination capabilities. In this study, the contrast-enhanced spectral mammography based on a PCD was implemented by using a polychromatic dual-energy model, and the proposed technique was compared with the dual-energy technique with an EID in terms of quantitative accuracy and radiation dose. The results showed that the proposed technique improved the quantitative accuracy as well as reduced radiation dose comparing to the dual-energy technique with an EID. The quantitative accuracy of the contrast-enhanced spectral mammography based on a PCD was slightly improved as a function of radiation dose. Therefore, the contrast-enhanced spectral mammography based on a PCD is able to provide useful information for detecting breast tumors and improving diagnostic accuracy.

  1. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.

    PubMed

    Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA

  2. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging

    PubMed Central

    Morris, Elizabeth A.; Kaplan, Jennifer B.; D’Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S.

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material–enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board–approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%–76%) and MR imaging (69%–76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55–0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images

  3. Contribution of mammography to MRI screening in BRCA mutation carriers by BRCA status and age: individual patient data meta-analysis

    PubMed Central

    Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine MA; van den Heuvel, Edwin R; Houssami, Nehmat

    2016-01-01

    Background: We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Methods: Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. Results: In BRCA1/2 mutation carriers of all ages (BRCA1=1219 and BRCA2=732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P>0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Conclusions: Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering. PMID:26908327

  4. Contribution of mammography to MRI screening in BRCA mutation carriers by BRCA status and age: individual patient data meta-analysis.

    PubMed

    Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine M A; van den Heuvel, Edwin R; Houssami, Nehmat

    2016-03-15

    We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. In BRCA1/2 mutation carriers of all ages (BRCA1 = 1,219 and BRCA2 = 732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P > 0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽ 40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering.

  5. Deep learning in mammography and breast histology, an overview and future trends.

    PubMed

    Hamidinekoo, Azam; Denton, Erika; Rampun, Andrik; Honnor, Kate; Zwiggelaar, Reyer

    2018-07-01

    Recent improvements in biomedical image analysis using deep learning based neural networks could be exploited to enhance the performance of Computer Aided Diagnosis (CAD) systems. Considering the importance of breast cancer worldwide and the promising results reported by deep learning based methods in breast imaging, an overview of the recent state-of-the-art deep learning based CAD systems developed for mammography and breast histopathology images is presented. In this study, the relationship between mammography and histopathology phenotypes is described, which takes biological aspects into account. We propose a computer based breast cancer modelling approach: the Mammography-Histology-Phenotype-Linking-Model, which develops a mapping of features/phenotypes between mammographic abnormalities and their histopathological representation. Challenges are discussed along with the potential contribution of such a system to clinical decision making and treatment management. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  6. TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, H; Cho, H; Kumar, N

    Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low-more » and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.« less

  7. Travel by public transit to mammography facilities in 6 US urban areas.

    PubMed

    Graham, S; Lewis, B; Flanagan, B; Watson, M; Peipins, L

    2015-12-01

    We examined lack of private vehicle access and 30 minutes or longer public transportation travel time to mammography facilities for women 40 years of age or older in the urban areas of Boston, Philadelphia, San Antonio, San Diego, Denver, and Seattle to identify transit marginalized populations - women for whom these travel characteristics may jointly present a barrier to clinic access. This ecological study used sex and race/ethnicity data from the 2010 US Census and household vehicle availability data from the American Community Survey 2008-2012, all at Census tract level. Using the public transportation option on Google Trip Planner we obtained the travel time from the centroid of each census tract to all local mammography facilities to determine the nearest mammography facility in each urban area. Median travel times by public transportation to the nearest facility for women with no household access to a private vehicle were obtained by ranking travel time by population group across all U.S. census tracts in each urban area and across the entire study area. The overall median travel times for each urban area for women without household access to a private vehicle ranged from a low of 15 minutes in Boston and Philadelphia to 27 minutes in San Diego. The numbers and percentages of transit marginalized women were then calculated for all urban areas by population group. While black women were less likely to have private vehicle access, and both Hispanic and black women were more likely to be transit marginalized, this outcome varied by urban area. White women constituted the largest number of transit marginalized. Our results indicate that mammography facilities are favorably located for the large majority of women, although there are still substantial numbers for whom travel may likely present a barrier to mammography facility access.

  8. Travel by public transit to mammography facilities in 6 US urban areas

    PubMed Central

    Graham, S; Lewis, B; Flanagan, B; Watson, M; Peipins, L

    2017-01-01

    We examined lack of private vehicle access and 30 minutes or longer public transportation travel time to mammography facilities for women 40 years of age or older in the urban areas of Boston, Philadelphia, San Antonio, San Diego, Denver, and Seattle to identify transit marginalized populations - women for whom these travel characteristics may jointly present a barrier to clinic access. This ecological study used sex and race/ethnicity data from the 2010 US Census and household vehicle availability data from the American Community Survey 2008–2012, all at Census tract level. Using the public transportation option on Google Trip Planner we obtained the travel time from the centroid of each census tract to all local mammography facilities to determine the nearest mammography facility in each urban area. Median travel times by public transportation to the nearest facility for women with no household access to a private vehicle were obtained by ranking travel time by population group across all U.S. census tracts in each urban area and across the entire study area. The overall median travel times for each urban area for women without household access to a private vehicle ranged from a low of 15 minutes in Boston and Philadelphia to 27 minutes in San Diego. The numbers and percentages of transit marginalized women were then calculated for all urban areas by population group. While black women were less likely to have private vehicle access, and both Hispanic and black women were more likely to be transit marginalized, this outcome varied by urban area. White women constituted the largest number of transit marginalized. Our results indicate that mammography facilities are favorably located for the large majority of women, although there are still substantial numbers for whom travel may likely present a barrier to mammography facility access. PMID:29285434

  9. Creating a national culture of quality: the Tanzania experience.

    PubMed

    Mwidunda, Patrick E; Eliakimu, Eliudi

    2015-07-01

    Although quality improvement has been a priority for Tanzania's health sector since the 1970s, few effective quality improvement initiatives were implemented, due to limited expertise, political commitment and resources. More recently, as the HIV epidemic gained momentum within the country, an influx of funding and of international organizations with quality improvement expertise accelerated the implementation of quality improvement projects, as well as efforts to institutionalize quality improvement at the national level. The support of US President's Emergency Plan for AIDS Relief (PEPFAR) and other donors, and the increasing numbers of HIV-implementing partners focused on quality management, and quality improvement strategies catalysed the development of HIV-specific quality improvement initiatives first, and then of national quality improvement frameworks. The diversity of quality improvement approaches championed by various donors and partners also presented important challenges to harmonization and institutionalization of quality improvement programmes.

  10. Cost-effectiveness of breast cancer screening using mammography in Vietnamese women

    PubMed Central

    2018-01-01

    Background The incidence rate of breast cancer is increasing and has become the most common cancer in Vietnamese women while the survival rate is lower than that of developed countries. Early detection to improve breast cancer survival as well as reducing risk factors remains the cornerstone of breast cancer control according to the World Health Organization (WHO). This study aims to evaluate the costs and outcomes of introducing a mammography screening program for Vietnamese women aged 45–64 years, compared to the current situation of no screening. Methods Decision analytical modeling using Markov chain analysis was used to estimate costs and health outcomes over a lifetime horizon. Model inputs were derived from published literature and the results were reported as incremental cost-effectiveness ratios (ICERs) and/or incremental net monetary benefits (INMBs). One-way sensitivity analyses and probabilistic sensitivity analyses were performed to assess parameter uncertainty. Results The ICER per life year gained of the first round of mammography screening was US$3647.06 and US$4405.44 for women aged 50–54 years and 55–59 years, respectively. In probabilistic sensitivity analyses, mammography screening in the 50–54 age group and the 55–59 age group were cost-effective in 100% of cases at a threshold of three times the Vietnamese Gross Domestic Product (GDP) i.e., US$6332.70. However, less than 50% of the cases in the 60–64 age group and 0% of the cases in the 45–49 age group were cost effective at the WHO threshold. The ICERs were sensitive to the discount rate, mammography sensitivity, and transition probability from remission to distant recurrence in stage II for all age groups. Conclusion From the healthcare payer viewpoint, offering the first round of mammography screening to Vietnamese women aged 50–59 years should be considered, with the given threshold of three times the Vietnamese GDP per capita. PMID:29579131

  11. Factors influencing the mammography utilization among Taiwanese women with intellectual disabilities, a nationwide population-based study.

    PubMed

    Lai, Hsien-Tang; Kung, Pei-Tseng; Tsai, Wen-Chen

    2014-12-01

    Women with intellectual disabilities (ID) have cognitive impairment and communication difficulties; for both caregivers and clinical personnel, discovering the early symptoms of breast cancer among women with ID is challenging. The mammography utilization rate of women with ID was significantly lower than that of women in the general population. This study employed a 2008 database of people with disabilities in Taiwan as a research target and analyzed the mammography utilization rate of women with ID aged 50–69 years. In addition, relevant factors influencing mammography utilization among women with ID were also investigated. A total of 4370 participants were recruited and the majority were illiterate or had elementary-level educations (82.27%). The majority of the participants had ID that was more severe than mild (83.80%). The mammography utilization rate of women with ID was 4.32%, which was significantly lower than that of women in the general population (12%). The mammography utilization rate among women with ID who were married, had higher education levels, and had been diagnosed with cancer, diabetes, or mild ID was significantly higher. However, the mammography utilization rate among women with ID, who had elementary-level educations or were illiterate, was only 4.03%. The utilization rate among women with profound ID was only 2.65%. Women with ID who had undergone pap smears or had utilized adult preventive health services demonstrated a significantly higher mammography utilization rate. This study identified that education level, a diagnosis of diabetes, and the application of pap smears or adult preventive health services were primary factors that influenced the mammography utilization rate among women with ID. This study also observed that in Taiwan, the mammography utilization rate of women with ID was lower than that of pap smears and adult preventive health services, and was only half of that of people with disabilities. An unequal situation

  12. Breast cancer stage at diagnosis and geographic access to mammography screening (New Hampshire, 1998-2004).

    PubMed

    Celaya, Maria O; Berke, Ethan M; Onega, Tracy L; Gui, Jiang; Riddle, Bruce L; Cherala, Sai S; Rees, Judy R

    2010-01-01

    Early detection of breast cancer by screening mammography aims to increase treatment options and decrease mortality. Recent studies have shown inconsistent results in their investigations of the possible association between travel distance to mammography and stage of breast cancer at diagnosis. The purpose of the study was to investigate whether geographic access to mammography screening is associated with the stage at breast cancer diagnosis. Using the state's population-based cancer registry, all female residents of New Hampshire aged > or =40 years who were diagnosed with breast cancer during 1998-2004 were identified. The factors associated with early stage (stages 0 to 2) or later stage (stages 3 and 4) diagnosis of breast cancer were compared, with emphasis on the distance a woman lived from the closest mammography screening facility, and residence in rural and urban locations. A total of 5966 New Hampshire women were diagnosed with breast cancer during 1998-2004. Their mean driving distance to the nearest mammography facility was 8.85 km (range 0-44.26; 5.5 miles, range 0-27.5), with a mean estimated travel time of 8.9 min (range 0.0-42.2). The distribution of travel distance (and travel time) was substantially skewed to the right: 56% of patients lived within 8 km (5 miles) of a mammography facility, and 65% had a travel time of less than 10 min. There was no significant association between later stage of breast cancer and travel time to the nearest mammography facility. Using 3 categories of rural/urban residence based on Rural Urban Commuting Area classification, no significant association between rural residence and stage of diagnosis was found. New Hampshire women were more likely to be diagnosed with breast cancer at later stages if they lacked private health insurance (p<0.001), were not married (p<0.001), were older (p<0.001), and there was a borderline association with diagnosis during non-winter months (p=0.074). Most women living in New Hampshire

  13. A cost-effectiveness comparison of three tailored interventions to increase mammography screening.

    PubMed

    Saywell, Robert M; Champion, Victoria L; Skinner, Celette Sugg; Menon, Usha; Daggy, Joanne

    2004-10-01

    Mammography is the primary method used for breast cancer screening. However, adherence to recommended screening practices is still below acceptable levels. This study examined the cost-effectiveness of three combinations of tailored telephone and mailed intervention strategies for increasing adherence to mammography. There were 1044 participants who were randomly assigned to one of four groups. A logistic regression model with adherence as the dependent variable and group as the independent variable was used to test for significant differences, and a ratio of cost/improvement in mammogram adherence evaluated the cost-effectiveness. All three of the interventions (tailored telephone, tailored mail, and tailored telephone and mail) had significantly better adherence rates compared with the control group (usual care). However, when also considering costs, one emerged as the superior strategy. The cost-effectiveness ratios for the three interventions show that the tailored mail (letter) was the most cost-effective strategy, achieving 43.3% mammography adherence at a marginal cost of dollar 0.39 per 1% increase in women screened. The tailored mail plus telephone achieved greater adherence (49.4%), but at a higher cost (dollar 0.56 per 1% increase in women screened). A tailored mail reminder is an effective and economical intervention to increase mammography adherence. Future research should confirm this finding and address its applicability to practice in other settings.

  14. A multi-centre randomised trial comparing ultrasound vs mammography for screening breast cancer in high-risk Chinese women.

    PubMed

    Shen, S; Zhou, Y; Xu, Y; Zhang, B; Duan, X; Huang, R; Li, B; Shi, Y; Shao, Z; Liao, H; Jiang, J; Shen, N; Zhang, J; Yu, C; Jiang, H; Li, S; Han, S; Ma, J; Sun, Q

    2015-03-17

    Chinese women tend to have small and dense breasts and ultrasound is a common method for breast cancer screening in China. However, its efficacy and cost comparing with mammography has not been evaluated in randomised trials. At 14 breast centres across China during 2008-2010, 13 339 high-risk women aged 30-65 years were randomised to be screened by mammography alone, ultrasound alone, or by both methods at enrollment and 1-year follow-up. A total of 12 519 and 8692 women underwent the initial and second screenings, respectively. Among the 30 cancers (of which 15 were stage 0/I) detected, 5 (0.72/1000) were in the mammography group, 11 (1.51/1000) in the ultrasound group, and 14 (2.02/1000) in the combined group (P=0.12). In the combined group, ultrasound detected all the 14 cancers, whereas mammography detected 8, making ultrasound more sensitive (100 vs 57.1%, P=0.04) with a better diagnostic accuracy (0.999 vs 0.766, P=0.01). There was no difference between mammography and ultrasound in specificity (100 vs 99.9%, P=0.51) and positive predictive value (72.7 vs 70.0%; P=0.87). To detect one cancer, the costs of ultrasound, mammography, and combined modality were $7876, $45 253, and $21 599, respectively. Ultrasound is superior to mammography for breast cancer screening in high-risk Chinese women.

  15. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    PubMed Central

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O’Connell, Avice M.; Conover, David L.

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of mean glandular dose to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 mGy to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9±4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4±6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum-minimum) of MGD from dedicated breast CT was

  16. Optimization of contrast-enhanced spectral mammography depending on clinical indication

    PubMed Central

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-01-01

    Abstract. The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality. PMID:26158058

  17. Print information to inform decisions about mammography screening participation in 16 countries with population-based programs.

    PubMed

    Zapka, Jane G; Geller, Berta M; Bulliard, Jean-Luc; Fracheboud, Jacques; Sancho-Garnier, Helene; Ballard-Barbash, Rachel

    2006-10-01

    To profile and compare the content and presentation of written communications related to informed decision-making about mammography. Materials from 16 screening programs organized at the national or regional level were analyzed according to five major information domains suggested by the international literature. A majority of countries provided information on the program (interval, cost and quality). There was considerable variability in comprehensiveness of elements in the domains, e.g., test characteristics (false positive/negative) and pros and cons of screening. The majority noted the likelihood of recall for further tests, few commented on the risks of additional tests or finding unimportant tumors. The audit also found variation in presentation (words and pictures). Presentation of comprehensive, but balanced information on screening benefits and risks is complex and daunting. Issues such as framing effects, coupled with debate about screening efficacy are challenging to the design of effective information tools. The objective of increasing screening prevalence at the population level must be balanced with objectively presenting complete and clear information. Additional research is needed on how information (and mode of presentation) impact screening decisions. Public health officials need to articulate their objectives and review written communication according to important decision-making domains.

  18. Dose assessment in contrast enhanced digital mammography using simple phantoms simulating standard model breasts.

    PubMed

    Bouwman, R W; van Engen, R E; Young, K C; Veldkamp, W J H; Dance, D R

    2015-01-07

    Slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE) slabs are used to simulate standard model breasts for the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT). These phantoms are optimized for the energy spectra used in DM and DBT, which normally have a lower average energy than used in contrast enhanced digital mammography (CEDM). In this study we have investigated whether these phantoms can be used for the evaluation of AGD with the high energy x-ray spectra used in CEDM. For this purpose the calculated values of the incident air kerma for dosimetry phantoms and standard model breasts were compared in a zero degree projection with the use of an anti scatter grid. It was found that the difference in incident air kerma compared to standard model breasts ranges between -10% to +4% for PMMA slabs and between 6% and 15% for PMMA-PE slabs. The estimated systematic error in the measured AGD for both sets of phantoms were considered to be sufficiently small for the evaluation of AGD in quality control procedures for CEDM. However, the systematic error can be substantial if AGD values from different phantoms are compared.

  19. National Water-Quality Assessment Program - Red River of the North

    USGS Publications Warehouse

    Stoner, J.D.

    1991-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status and trends in the quality of a large, representative part of the Nation's surface- and ground-water resources, and to provide a sound scientific understanding of the primary natural and human factors affecting the quality of these resources. The program will produce a wealth of water-quality information that will be useful to policy makers and managers at the national, State, and local levels.

  20. Improved visualization of breast cancer features in multifocal carcinoma using phase-contrast and dark-field mammography: an ex vivo study.

    PubMed

    Grandl, Susanne; Scherer, Kai; Sztrókay-Gaul, Anikó; Birnbacher, Lorenz; Willer, Konstantin; Chabior, Michael; Herzen, Julia; Mayr, Doris; Auweter, Sigrid D; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin

    2015-12-01

    Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. • X-ray dark-field mammography provides significantly improved visualization of tumour features • X-ray dark-field mammography is capable of outperforming conventional mammographic imaging • X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains.

  1. Screening Mammography for Free: Impact of Eliminating Cost Sharing on Cancer Screening Rates.

    PubMed

    Jena, Anupam B; Huang, Jie; Fireman, Bruce; Fung, Vicki; Gazelle, Scott; Landrum, Mary Beth; Chernew, Michael; Newhouse, Joseph P; Hsu, John

    2017-02-01

    To study the impact of eliminating cost sharing for screening mammography on mammography rates in a large Medicare Advantage (MA) health plan which in 2010 eliminated cost sharing in anticipation of the Affordable Care Act mandate. Large MA health maintenance organization offering individual-subscriber MA insurance and employer-supplemented group MA insurance. We investigated the impact on breast cancer screening of a policy that eliminated a $20 copayment for screening mammography in 2010 among 53,188 women continuously enrolled from 2007 to 2012 in an individual-subscriber MA plan, compared with 42,473 women with employer-supplemented group MA insurance in the same health maintenance organization who had full screening coverage during this period. We used differences-in-differences analysis to study the impact of cost-sharing elimination on mammography rates. Annual screening rates declined over time for both groups, with similar trends pre-2010 and a slower decline after 2010 among women whose copayments were eliminated. Among women aged 65-74 years in the individual-subscriber MA plan, 44.9 percent received screening in 2009 compared with 40.9 percent in 2012, while 49.5 percent of women in the employer-supplemented MA plan received screening in 2009 compared with 44.1 percent in 2012, that is, a difference-in-difference effect of 1.4 percentage points less decline in screening among women experiencing the cost-sharing elimination. Effects were concentrated among women without recent screening. There were no differences by neighborhood socioeconomic status or race/ethnicity. Eliminating cost sharing for screening mammography was associated with modesty lower decline in screening rates among women with previously low screening adherence. © Health Research and Educational Trust.

  2. Sustaining Mammography Screening Among the Medically Underserved: A Follow-Up Evaluation

    PubMed Central

    Arnold, Connie L.; Bennett, Charles L.; Wolf, Michael S.; Liu, Dachao; Rademaker, Alfred

    2015-01-01

    Abstract Background: Our previous three-arm comparative effectiveness intervention in community clinic patients who were not up-to-date with screening resulted in mammography rates over 50% in all arms. Objective: Our aim was to evaluate the effectiveness and cost-effectiveness of the three interventions on improving biennial screening rates among eligible patients. Methods: A three-arm quasi-experimental evaluation was conducted in eight community clinics from 2008 to 2011. Screening efforts included (1) enhanced care: Participants received an in-person recommendation from a research assistant (RA) in year 1, and clinics followed usual clinic protocol for scheduling screening mammograms; (2) education intervention: Participants received education and in-person recommendation from an RA in year 1, and clinics followed usual clinic protocol for scheduling mammograms; or (3) nurse support: A nurse manager provided in-person education and recommendation, scheduled mammograms, and followed up with phone support. In all arms, mammography was offered at no cost to uninsured patients. Results: Of 624 eligible women, biennial mammography within 24–30 months of their previous test was performed for 11.0% of women in the enhanced-care arm, 7.1% in the education- intervention arm, and 48.0% in the nurse-support arm (p<0.0001). The incremental cost was $1,232 per additional woman undergoing screening with nurse support vs. enhanced care and $1,092 with nurse support vs. education. Conclusions: Biennial mammography screening rates were improved by providing nurse support but not with enhanced care or education. However, this approach was not cost-effective. PMID:25692910

  3. Mobile mammography: An evaluation of organizational, process, and information systems challenges.

    PubMed

    Browder, Casey; Eberth, Jan M; Schooley, Benjamin; Porter, Nancy R

    2015-03-01

    The purpose of this case study was to evaluate the information systems, personnel, and processes involved in mobile mammography settings, and offer recommendations to improve efficiency and satisfaction among patients and staff. Data includes on-site observations, interviews, and an electronic medical record review of a hospital who offers both mobile and fixed facility mammography services to their community. The optimal expectations for the process of mobile mammography from multiple perspectives were defined as (1) patient receives mammogram the day of their visit, (2) patient has efficient intake process with little wait time, (3) follow-up is completed and timely, (4) site contact and van staff are satisfied with van visit and choose to schedule future visits, and (5) the MMU is able to assess its performance and set goals for improvement. Challenges that prevent the realization of those expectations include a low patient pre-registration rate, difficulty obtaining required physician orders, frequent information system downtime/Internet connectivity issues, ill-defined organizational communication/roles, insufficient site host/patient education, and disparate organizational and information systems. Our recommendations include employing a dedicated mobile mammography team for end-to-end oversight, mitigating for system connectivity issues, allowing for patient self-referrals, integrating scheduling and registration processes, and a focused approach to educating site hosts and respective patients about expectations for the day of the visit. The MMU is an important community resource; we recommend simple process improvements and information flow improvements to further enable the MMU׳s goals. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Validation of a condition-specific measure for women having an abnormal screening mammography.

    PubMed

    Brodersen, John; Thorsen, Hanne; Kreiner, Svend

    2007-01-01

    The aim of this study is to assess the validity of a new condition-specific instrument measuring psychosocial consequences of abnormal screening mammography (PCQ-DK33). The draft version of the PCQ-DK33 was completed on two occasions by 184 women who had received an abnormal screening mammography and on one occasion by 240 women who had received a normal screening result. Item Response Theories and Classical Test Theories were used to analyze data. Construct validity, concurrent validity, known group validity, objectivity and reliability were established by item analysis examining the fit between item responses and Rasch models. Six dimensions covering anxiety, behavioral impact, sense of dejection, impact on sleep, breast examination, and sexuality were identified. One item belonging to the dejection dimension had uniform differential item functioning. Two items not fitting the Rasch models were retained because of high face validity. A sick leave item added useful information when measuring side effects and socioeconomic consequences of breast cancer screening. Five "poor items" were identified and should be deleted from the final instrument. Preliminary evidence for a valid and reliable condition-specific measure for women having an abnormal screening mammography was established. The measure includes 27 "good" items measuring different attributes of the same overall latent structure-the psychosocial consequences of abnormal screening mammography.

  5. Inequity of healthcare utilization on mammography examination and Pap smear screening in Thailand: Analysis of a population-based household survey

    PubMed Central

    2017-01-01

    Healthcare in Thailand is not equally distributed, and not all people can equally access healthcare resources even if they are covered by health insurance. To examine factors associated with the utilization of mammography examination for breast cancer and Pap smear screening for cervical cancer, data from the national reproductive health survey conducted by the National Statistical Office of Thailand in 2009 was examined. The survey was carried out on 15,074,126 women aged 30–59 years. The results showed that the wealthier respondents had more mammograms than did the lower-income groups. The concentration index was 0.144. The data on Pap smears for cervical cancer also showed that the wealthier respondents were more likely to have had a Pap smear than their lower-income counterparts. The concentration index was 0.054. Determinants of mammography examination were education, followed by health welfare and wealth index, whereas the determinants of Pap smear screening were wealth index, followed by health welfare and education. The government should support greater education for women because education was associated with socioeconomic status and wealth. There should be an increase in the number of screening campaigns, mobile clinics, and low-cost mammograms and continued support for accessibility to mammograms, especially in rural areas and low-income communities. PMID:28282430

  6. The Veterans Affairs National Quality Scholars program: a model for interprofessional education in quality and safety.

    PubMed

    Patrician, Patricia A; Dolansky, Mary A; Pair, Vincent; Bates, Mekeshia; Moore, Shirley M; Splaine, Mark; Gilman, Stuart C

    2013-01-01

    The Quality and Safety Education for Nurses (QSEN) project is enhancing the emphasis on quality care and patient safety content in nursing schools. A partnership between QSEN and the Veterans Affairs National Quality Scholars program resulted in a unique experiential, interdisciplinary fellowship for both nurses and physicians. This article introduces the Veterans Affairs National Quality Scholars program and provides examples of learning activities and fellows' accomplishments. Interprofessional quality and safety education at the doctoral and postdoctoral levels is germane to improving the quality of health care.

  7. National Water-Quality Assessment program: The Trinity River Basin

    USGS Publications Warehouse

    Land, Larry F.

    1991-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status and trends in the quality of a large, representative part of the Nation's surface- and ground-water resources and to provide a sound, scientific understanding of the primary natural and human factors affecting the quality of these resources. In meeting these goals, the program will produce a wealth of water-quality information that will be useful to policy makers and managers at the national, State, and local levels. A major design feature of the NAWQA program will enable water-quality information at different areal scales to be integrated. A major component of the program is study-unit investigations, which comprise the principal building blocks of the program on which national-level assessment activities will be based. The 60 study-unit investigations that make up the program are hydrologic systems that include parts of most major river basins and aquifer systems. These study units cover areas of 1,200 to more than 65,000 square miles and incorporate about 60 to 70 percent of the Nation's water use and population served by public water supply. In 1991, the Trinity River basin study was among the first 20 NAWQA study units selected for study under the full-scale implementation plan.

  8. National Water-Quality Assessment Program: The Sacramento River Basin

    USGS Publications Warehouse

    Domagalski, Joseph L.; Brown, Larry R.

    1994-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status of and trends in the quality of a large, representative part of the Nation's surface- and ground-water resources and to identify the major natural and human factors that affect the quality of those resources. In addressing these goals, the program will provide a wealth of water- quality information that will be useful to policy makers and managers at the national, State, and local levels. A major asset of the NAWQA program is that it will allow for the integration of water-quality information collected at several scales. A major component of the program is the study-unit investigation-the foundation of national- level assessment. The 60 study units of the NAWQA program are hydrologic systems that include parts of most major river basins and aquifer systems of the conterminous United States. These study units cover areas of 1,000 to more than 60,000 square miles and represent 60 to 70 percent of the Nation's water use and population served by public water supplies. Investigations of the first 20 study units began in 1991. In 1994, the Sacramento River Basin was among the second set of 20 NAWQA study units selected for investigation.

  9. Nonpoint Source: National Water Quality Initiative

    EPA Pesticide Factsheets

    National Water Quality Initiative (NWQI) is a collaborative between EPA and Natural Resource Conservation Service ( NRCS) that began in 2012. NWQI provides a means to accelerate voluntary, private lands conservation practices

  10. Healthcare Use and Mammography Among Latinas With and Without Health Insurance Near the US-Mexico Border.

    PubMed

    Lapeyrouse, Lisa M; Miranda, Patricia Y; Morera, Osvaldo F; Heyman, Josiah McC; Balcazar, Hector G

    2017-04-01

    Among Latinas, lacking health insurance and having lower levels of acculturation are associated with disparities in mammography screening. We seek to investigate whether differences in lifetime mammography exist between Latina border residents by health insurance status and health care site (i.e., U.S. only or a combination of U.S. and Mexican health care). Using data from the 2009 to 2010 Ecological Household Study on Latino Border Residents, mammography screening was examined among (n = 304) Latinas >40 years old. While more acculturated women were significantly (p < .05) more likely to report ever having a mammogram than less acculturated women, ever having a mammogram was not predicted by health care site or insurance status. Latinas who utilize multiple systems of care have lower levels of acculturation and health insurance, thus representing an especially vulnerable population for experiencing disparities in mammography screening.

  11. Compositional breast imaging using a dual-energy mammography protocol

    PubMed Central

    Laidevant, Aurelie D.; Malkov, Serghei; Flowers, Chris I.; Kerlikowske, Karla; Shepherd, John A.

    2010-01-01

    Purpose: Mammography has a low sensitivity in dense breasts due to low contrast between malignant and normal tissue confounded by the predominant water density of the breast. Water is found in both adipose and fibroglandular tissue and constitutes most of the mass of a breast. However, significant protein mass is mainly found in the fibroglandular tissue where most cancers originate. If the protein compartment in a mammogram could be imaged without the influence of water, the sensitivity and specificity of the mammogram may be improved. This article describes a novel approach to dual-energy mammography, full-field digital compositional mammography (FFDCM), which can independently image the three compositional components of breast tissue: water, lipid, and protein. Methods: Dual-energy attenuation and breast shape measures are used together to solve for the three compositional thicknesses. Dual-energy measurements were performed on breast-mimicking phantoms using a full-field digital mammography unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the compositional compartments. They were made of two main stacks of thicknesses around 2 and 4 cm. Twenty-six thickness and composition combinations were used to derive the compositional calibration using a least-squares fitting approach. Results: Very high accuracy was achieved with a simple cubic fitting function with root mean square errors of 0.023, 0.011, and 0.012 cm for the water, lipid, and protein thicknesses, respectively. The repeatability (percent coefficient of variation) of these measures was tested using sequential images and was found to be 0.5%, 0.5%, and 3.3% for water, lipid, and protein, respectively. However, swapping the location of the two stacks of the phantom on the imaging plate introduced further errors showing the need for more complete system uniformity corrections. Finally, a preliminary breast image is presented of each of the compositional

  12. Diagnostic accuracy of contrast-enhanced spectral mammography in comparison to conventional full-field digital mammography in a population of women with dense breasts.

    PubMed

    Mori, Miki; Akashi-Tanaka, Sadako; Suzuki, Satoko; Daniels, Murasaki Ikeda; Watanabe, Chie; Hirose, Masanori; Nakamura, Seigo

    2017-01-01

    Contrast-enhanced spectral mammography to compare clinical efficacy of contrast-enhanced spectral mammography (CESM) and conventional digital mammography (MMG) with histopathology as gold standard in dense breasts. A total of 143 breasts of 72 women who underwent CESM and MMG between 2011 and 2014 at Showa University Hospital were analyzed. 129 (90.2 %) of 143 breasts revealed dense breasts on MMG. 58 (40.6 %) of 143 breasts were diagnosed with breast cancer at histopathology. The remaining 85 breasts were diagnosed with benign findings after image assessments and/or core needle biopsy. CESM revealed 8 false-negative cases among 58 breast cancer cases (sensitivity 86.2 %) and 5 false-positive cases (specificity 94.1 %). Accuracy was 90.9 %. Conventional MMG was assessed true positive in 31 of 58 breast cancer cases (sensitivity 53.4 %) and false positive in 12 cases (specificity 85.9 %). Accuracy was 72.7 %. Sensitivity (p < 0.001), specificity (p = 0.016) and accuracy (p < 0.001) were significantly higher on CESM compared to MMG. MMG missed malignancy in 27 breasts. Of these, 25 were dense breasts. Of these 25, 20 (80.0 %) breasts were positive on CESM. These findings suggest that CESM offers superior clinical performance compared to MMG. Use of CESM may decrease false negatives especially for women with dense breasts.

  13. National program of breast cancer early detection in Brod-Posavina County (East Croatia).

    PubMed

    Jurišić, Irena; Kolovrat, Ana; Mitrečić, Drago; Cvitković, Ante

    2014-09-01

    Results of the National Program of Breast Cancer Early Detection in Brod-Posavina County during the 2006-2012 period are presented. Response rate in two National Program cycles, cancers detected according to factors such as first and last menstruation, age at cancer detection, deliveries and mammography findings according to the Breast Imaging Reporting and Data System (BI-RADS) before diagnosis verification were analyzed. Data were obtained from the software connecting Public Health Institutes via Ministry of Health server and questionnaires filled out by the women presenting for screening and processed by the method of descriptive statistics. Mammography findings were classified according to the BI-RADS classification. In two National Program cycles during the 2006-2012 period, women aged 50-69 were called for mammography screening. In the first cycle, the response rate in Brod-Posavina County was 53.2%, with 71 cancers detected at a mean age of 61.3 years. In the second cycle, the response rate was 57.0%, with 44 cancers detected at a mean age of 62.5 years. In the first and second cycles, there were 21.1% and 14.3% of mammography findings requiring additional work-up (BI-RADS 0), respectively. Particular risk factors such as early menarche, late menopause, parity, positive family history and presence of benign breast lesions were not demonstrated in women with verified cancer. There was no increase in the incidence of breast cancer per 100,000 inhabitants in the Brod-Posavina County following implementation of the National Program. In conclusion, efforts should be focused on increasing public health awareness, ensuring appropriate professional staff engaged in screening, and improving medical care in order to reduce the time elapsed from establishing suspicion to confirming the diagnosis of breast cancer.

  14. Entertainment-Education Narrative Versus Nonnarrative Interventions to Educate and Motivate Latinas to Engage in Mammography Screening.

    PubMed

    Borrayo, Evelinn A; Rosales, Monica; Gonzalez, Patricia

    2017-06-01

    The evidence is limited comparing the effects of entertainment-education (E-E) narrative versus nonnarrative interventions to educate and motivate Latinas to engage in mammography screening. This study compared an E-E narrative intervention to two nonnarrative interventions' effects among Latinas on breast cancer knowledge and motivation, as measured by changes in self-efficacy, behavioral norms, and behavioral intentions to engage in mammography screening. A sample of 141 Spanish-speaking Latinas was randomly assigned to one of three arms: an E-E narrative video, a nonnarrative educational video, and printed educational materials. Using a repeated measures design, the influence of the E-E narrative on pretest to posttest measures was assessed and compared to the influence of the other two interventions. The E-E narrative and nonnarrative interventions significantly increased Latinas' breast cancer knowledge, mammography self-efficacy, and behavioral norms from pretest to posttest. However, the E-E narrative participants' pretest to posttest difference in mammography self-efficacy was significantly higher when compared to the difference of the other two interventions. The effect of the E-E narrative intervention on self-efficacy and behavioral norms was moderated by the participants' absorption in the story and identification with the story characters. E-E narrative and nonnarrative interventions significantly educated and motivated Latinas to engage in mammography screening. The effects on mammography self-efficacy, an important precursor to behavior change, can be more strongly influenced by E-E narratives. Although E-E narrative and nonnarrative interventions were effective, the need still exists to assess if they can ultimately influence lifesaving breast cancer screening behaviors.

  15. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality

    NASA Astrophysics Data System (ADS)

    Helge Østerås, Bjørn; Skaane, Per; Gullien, Randi; Catrine Trægde Martinsen, Anne

    2018-02-01

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra™). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra™. AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  16. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality.

    PubMed

    Østerås, Bjørn Helge; Skaane, Per; Gullien, Randi; Martinsen, Anne Catrine Trægde

    2018-01-25

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra ™ ). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra ™ . AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  17. [Radiation dose evaluation in a photon-counting digital mammography unit].

    PubMed

    Matsubara, Kosuke; Matsumoto, China; Mochiya, Yuko; Toda, Kanako; Noto, Kimiya; Koshida, Kichiro

    2014-05-01

    The purpose of our study was to evaluate radiation dose and beam quality in photon-counting digital mammography (PCDM) and compare them with those in a full-field digital mammography (FFDM) unit. Dose variation in the X-ray tube axis direction, aluminum half-value layer, average glandular and skin doses, and contrast-to-noise ratio (CNR) were evaluated for the PCDM and FFDM units. In PCDM, the dose variation in the X-ray tube axis direction was greater than that in FFDM. At a tube voltage of 28 kV, the first half-value layers were 0.407 mmAl for PCDM, 0.357 mmAl for FFDM with a molybdenum target and molybdenum filter (Mo/Mo), and 0.579 mmAl for FFDM with a tungsten target and rhodium filter (W/Rh). The average glandular doses with 45-mm-equivalent breast thickness were 0.723 mGy for the PCDM, 1.55 mGy for the FFDM with Mo/Mo in low-dose mode, and 0.835 mGy for the FFDM with W/Rh in low-dose mode. In PCDM, the skin dose was equivalent to or lower than that in FFDM. The CNR was 2.65±0.04, 2.35±0.04, and 2.52±0.03 for the PCDM, FFDM with Mo/Mo, and that with W/Rh, respectively. The CNR for PCDM was significantly higher than that for FFDM (p<0.001). It is therefore possible to reduce the radiation dose to the patient by using a PCDM unit while maintaining a significantly higher CNR than with the FFDM unit.

  18. Information Extraction for Clinical Data Mining: A Mammography Case Study

    PubMed Central

    Nassif, Houssam; Woods, Ryan; Burnside, Elizabeth; Ayvaci, Mehmet; Shavlik, Jude; Page, David

    2013-01-01

    Breast cancer is the leading cause of cancer mortality in women between the ages of 15 and 54. During mammography screening, radiologists use a strict lexicon (BI-RADS) to describe and report their findings. Mammography records are then stored in a well-defined database format (NMD). Lately, researchers have applied data mining and machine learning techniques to these databases. They successfully built breast cancer classifiers that can help in early detection of malignancy. However, the validity of these models depends on the quality of the underlying databases. Unfortunately, most databases suffer from inconsistencies, missing data, inter-observer variability and inappropriate term usage. In addition, many databases are not compliant with the NMD format and/or solely consist of text reports. BI-RADS feature extraction from free text and consistency checks between recorded predictive variables and text reports are crucial to addressing this problem. We describe a general scheme for concept information retrieval from free text given a lexicon, and present a BI-RADS features extraction algorithm for clinical data mining. It consists of a syntax analyzer, a concept finder and a negation detector. The syntax analyzer preprocesses the input into individual sentences. The concept finder uses a semantic grammar based on the BI-RADS lexicon and the experts’ input. It parses sentences detecting BI-RADS concepts. Once a concept is located, a lexical scanner checks for negation. Our method can handle multiple latent concepts within the text, filtering out ultrasound concepts. On our dataset, our algorithm achieves 97.7% precision, 95.5% recall and an F1-score of 0.97. It outperforms manual feature extraction at the 5% statistical significance level. PMID:23765123

  19. Information Extraction for Clinical Data Mining: A Mammography Case Study.

    PubMed

    Nassif, Houssam; Woods, Ryan; Burnside, Elizabeth; Ayvaci, Mehmet; Shavlik, Jude; Page, David

    2009-01-01

    Breast cancer is the leading cause of cancer mortality in women between the ages of 15 and 54. During mammography screening, radiologists use a strict lexicon (BI-RADS) to describe and report their findings. Mammography records are then stored in a well-defined database format (NMD). Lately, researchers have applied data mining and machine learning techniques to these databases. They successfully built breast cancer classifiers that can help in early detection of malignancy. However, the validity of these models depends on the quality of the underlying databases. Unfortunately, most databases suffer from inconsistencies, missing data, inter-observer variability and inappropriate term usage. In addition, many databases are not compliant with the NMD format and/or solely consist of text reports. BI-RADS feature extraction from free text and consistency checks between recorded predictive variables and text reports are crucial to addressing this problem. We describe a general scheme for concept information retrieval from free text given a lexicon, and present a BI-RADS features extraction algorithm for clinical data mining. It consists of a syntax analyzer, a concept finder and a negation detector. The syntax analyzer preprocesses the input into individual sentences. The concept finder uses a semantic grammar based on the BI-RADS lexicon and the experts' input. It parses sentences detecting BI-RADS concepts. Once a concept is located, a lexical scanner checks for negation. Our method can handle multiple latent concepts within the text, filtering out ultrasound concepts. On our dataset, our algorithm achieves 97.7% precision, 95.5% recall and an F 1 -score of 0.97. It outperforms manual feature extraction at the 5% statistical significance level.

  20. A method to measure paddle and detector pressures and footprints in mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hogg, Peter; Szczepura, Katy; Darlington, Alison

    2013-04-15

    Purpose: Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is no consensus within the literature regarding how the IR should be positioned relative to the inframammary fold (IMF). No information exists within the literature to describe how pressure balancing between IR and paddle, and IR breast footprint, might be optimized. This paper describes a novel method for measuring the respective pressures applied to the breast from the IR and the paddle and amore » method to simultaneously measure the breast footprints on the IR and the paddle. Methods: Using a deformable breast phantom and electronic pressure-sensitive mat, area and pressure readings were gathered from two mammography machines and four paddles at 60, 80, and 100 N with the IR positioned at -2, -1, 0, +1, and +2 cm relative to the IMF (60 combinations in total). Results: Paddle and IR footprints were calculated along with a uniformity index (UI). For all four paddle/machine/pressure combinations the greatest IR footprint was achieved at IMF +2 cm. The UI indicates that the best pressure/footprint balance is achieved at IMF +1 cm. Conclusions: The authors' method appears to be suited to measuring breast footprints and pressures on IR and paddle and a human female study is planned.« less

  1. National water-quality assessment program : the Albemarle- Pamlico drainage

    USGS Publications Warehouse

    Lloyd, O.B.; Barnes, C.R.; Woodside, M.D.

    1991-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. Long-term goals of the NAWQA program are to describe the status and trends in the quality of a large, representative part of the Nation's surface- and ground-water resources and to provide a sound, scientific understanding of the primary natural and human factors affecting the quality of these resources. In meeting these goals, the program will produce a wealth of water quality information that will be useful to policy makers and managers at the national, State, and local levels. Study-unit investigations constitute a major component of the NAWQA program, forming the principal building blocks on which national-level assessment activities are based. The 60 study-unit investigations that make up the program are hydrologic systems that include parts of most major river basins and aquifer systems. These study units cover areas of 1,200 to more than 65,000 square miles and incorporate about 60 to 70 percent of the Nation's water use and population served by public water supply. In 1991, the Albemarle-Pamlico drainage was among the first 20 NAWQA study units selected for study under the full-scale implementation plan. The Albemarle-Pamlico drainage study will examine the physical, chemical, and biological aspects of water quality issues in a coordinated investigation of surface water and ground water in the Albemarle-Pamlico drainage basin. The quantity and quality of discharge from the Albemarle-Pamlico drainage basin contribute to some water quality problems in the biologically sensitive waters of Albemarle and Pamlico Sounds. A retrospective analysis of existing water quality data will precede a 3-year period of intensive data-collection and analysis activities. The data resulting from this study and the improved understanding of important processes and issues in the upstream part of the study unit will enhance understanding of the quality of

  2. MO-AB-207-00: ACR Update in MR, CT, Nuclear Medicine, and Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date asmore » the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.« less

  3. Maintaining quality in the UK breast screening program

    NASA Astrophysics Data System (ADS)

    Gale, Alastair

    2010-02-01

    Breast screening in the UK has been implemented for over 20 years and annually nearly two million women are now screened with an estimated 1,400 lives saved. Nationally, some 700 individuals interpret screening mammograms in almost 110 screening centres. Currently, women aged 50 to 70 are invited for screening every three years and by 2012 this age range will increase to 47 - 73 years. There is a rapid ongoing transition from using film mammograms to full field digital mammography such that in 2010 every screening centre will be partly digital. An early, and long running, concern has been how to ensure the highest quality of imaging interpretation across the UK, an issue enhanced by the use of a three year screening interval. To partly address this question a self assessment scheme was developed in 1988 and subsequently implemented nationally in the UK as a virtually mandatory activity. The scheme is detailed from its beginnings, through its various developments to current incarnation and future plans. This encompasses both radiological (single view screening, two view screening, mammographic film and full field digital mammography) as well as design changes (cases reported by means of: form filling; PDA; tablet PC; iPhone, and the internet). The scheme provides a rich data source which is regularly studied to examine different aspects of radiological performance. Overall it aids screening radiologists by giving them regular access to a range of difficult exemplar cases together with feedback on their performance as compared to their peers.

  4. [False positive result in mammography and its association with the presence of obesity: a case-control study].

    PubMed

    Castro-Ibarra, Marisela; Menchaca-Díaz, Rufino; Cabrales-Ruvalcaba, J Jesús; Luna-V Gómez, Rosa Alicia

    2016-01-01

    To analyze the association between a false positive result in mammography and obesity, inside the breast cancer early detection program in women affiliated to the Institute of Security and Social Services for Government and Municipality workers of the State of Baja California (ISSSTECALI). A case-control, retrospective study was done in women affiliated to ISSSTECALI to whom a mammography was performed between 2009 and 2012. Women with a false positive result in mammography were included as cases. Controls were women with a true negative result in mammography. Three controls were randomly selected for each case. Obesity was established with the body mass index (BMI) consigned in the woman's clinical file. Age and estrogen replacement therapy were included as co-variables. Seventy nine cases were identified and 237 controls were included. Obesity was observed in 54.4% of cases and in 41.3% of controls (odds ratio: 1.69; 95% confidence interval for odds ratio: 1.01-2.82; p value: 0.043). A logistic regression model including covariables maintained the observed association (p = 0.044). No association was found with analyzed co-variables. A false positive result in mammography was associated with the presence of obesity.

  5. Quantification of breast lesion compositions using low-dose spectral mammography: A feasibility study

    PubMed Central

    Ding, Huanjun; Sennung, David; Cho, Hyo-Min; Molloi, Sabee

    2016-01-01

    Purpose: The positive predictive power for malignancy can potentially be improved, if the chemical compositions of suspicious breast lesions can be reliably measured in screening mammography. The purpose of this study is to investigate the feasibility of quantifying breast lesion composition, in terms of water and lipid contents, with spectral mammography. Methods: Phantom and tissue samples were imaged with a spectral mammography system based on silicon-strip photon-counting detectors. Dual-energy calibration was performed for material decomposition, using plastic water and adipose-equivalent phantoms as the basis materials. The step wedge calibration phantom consisted of 20 calibration configurations, which ranged from 2 to 8 cm in thickness and from 0% to 100% in plastic water density. A nonlinear rational fitting function was used in dual-energy calibration of the imaging system. Breast lesion phantoms, made from various combinations of plastic water and adipose-equivalent disks, were embedded in a breast mammography phantom with a heterogeneous background pattern. Lesion phantoms with water densities ranging from 0% to 100% were placed at different locations of the heterogeneous background phantom. The water density in the lesion phantoms was measured using dual-energy material decomposition. The thickness and density of the background phantom were varied to test the accuracy of the decomposition technique in different configurations. In addition, an in vitro study was also performed using mixtures of lean and fat bovine tissue of 25%, 50%, and 80% lean weight percentages as the background. Lesions were simulated by using breast lesion phantoms, as well as small bovine tissue samples, composed of carefully weighed lean and fat bovine tissues. The water densities in tissue samples were measured using spectral mammography and compared to measurement using chemical decomposition of the tissue. Results: The thickness of measured and known water contents was

  6. Breast cancer stage at diagnosis and geographic access to mammography screening (New Hampshire, 1998–2004)

    PubMed Central

    Celaya, MO; Berke, EM; Onega, TL; Gui, J; Riddle, BL; Cherala, SS; Rees, JR

    2017-01-01

    Introduction Early detection of breast cancer by screening mammography aims to increase treatment options and decrease mortality. Recent studies have shown inconsistent results in their investigations of the possible association between travel distance to mammography and stage of breast cancer at diagnosis. Objective The purpose of the study was to investigate whether geographic access to mammography screening is associated with the stage at breast cancer diagnosis. Methods Using the state’s population-based cancer registry, all female residents of New Hampshire aged ≥40 years who were diagnosed with breast cancer during 1998–2004 were identified. The factors associated with early stage (stages 0 to 2) or later stage (stages 3 and 4) diagnosis of breast cancer were compared, with emphasis on the distance a woman lived from the closest mammography screening facility, and residence in rural and urban locations. Results A total of 5966 New Hampshire women were diagnosed with breast cancer during 1998–2004. Their mean driving distance to the nearest mammography facility was 8.85km (range 0–44.26; 5.5 miles, range 0–27.5), with a mean estimated travel time of 8.9 min (range 0.0–42.2). The distribution of travel distance (and travel time) was substantially skewed to the right: 56% of patients lived within 8 km (5 miles) of a mammography facility, and 65% had a travel time of less than 10 min. There was no significant association between later stage of breast cancer and travel time to the nearest mammography facility. Using 3 categories of rural/urban residence based on Rural Urban Commuting Area classification, no significant association between rural residence and stage of diagnosis was found. New Hampshire women were more likely to be diagnosed with breast cancer at later stages if they lacked private health insurance (p<0.001), were not married (p<0.001), were older (p<0.001), and there was a borderline association with diagnosis during non-winter months

  7. Digital mammography. Why hasn't it been approved for U.S. hospitals?

    PubMed

    2000-01-01

    Mammography is the only major imaging technique still unavailable in the United States in digital form. This is because the Food and Drug Administration (FDA) has been unable to devise an effective method for manufacturers to demonstrate the safety and efficacy of digital mammography systems. As a result, the agency has been unable to approve any of those systems for marketing in the United States. In this Regulatory Update, we describe FDA's recent efforts to help manufacturers obtain approval and the reasons those efforts have so far proved ineffective.

  8. Quantitative breast density analysis using tomosynthesis and comparison with MRI and digital mammography.

    PubMed

    Moon, Woo Kyung; Chang, Jie-Fan; Lo, Chung-Ming; Chang, Jung Min; Lee, Su Hyun; Shin, Sung Ui; Huang, Chiun-Sheng; Chang, Ruey-Feng

    2018-02-01

    Breast density at mammography has been used as markers of breast cancer risk. However, newly introduced tomosynthesis and computer-aided quantitative method could provide more reliable breast density evaluation. In the experiment, 98 tomosynthesis image volumes were obtained from 98 women. For each case, an automatic skin removal was used and followed by a fuzzy c-mean (FCM) classifier which separated the fibroglandular tissues from other tissues in breast area. Finally, percent of breast density and breast volume were calculated and the results were compared with MRI. In addition, the percent of breast density and breast area of digital mammography calculated using the software Cumulus (University of Toronto, Toronto, ON, Canada.) were also compared with 3-D modalities. Percent of breast density and breast volume, which were computed from tomosynthesis, MRI and digital mammography were 17.37% ± 4.39% and 607.12 cm 3  ± 323.01 cm 3 , 20.3% ± 8.6% and 537.59 cm 3  ± 287.74 cm 3 , and 12.03% ± 4.08%, respectively. There were significant correlations on breast density as well as volume between tomosynthesis and MRI (R = 0.482 and R = 0.805), tomosynthesis and breast density with breast area of digital mammography (R = 0.789 and R = 0.877), and MRI and breast density with breast area of digital mammography (R = 0.482 and R = 0.857) (all P values < .001). Breast density and breast volume evaluated from tomosynthesis, MRI and breast density and breast area of digital mammographic images have significant correlations and indicate that tomosynthesis could provide useful 3-D information on breast density through proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Measurement of X-ray intensity in mammography by a ferroelectric dosimeter

    NASA Astrophysics Data System (ADS)

    Alter, Albert J.

    2005-07-01

    Each year in the US over 20 million women undergo mammography, a relatively high dose x-ray examination of the breast, which is relatively sensitive to the carcinogenic effect of ionizing radiation. The radiation risk from mammography is usually expressed in terms of mean glandular dose (MGD) which is calculated as the product of measured entrance exposure (ESE) and a dose conversion factor which is a function of anode material, peak tube voltage (23 to 35 kVp), half-value layer, filtration, compressed breast thickness and breast composition. Mammographic units may have anodes made of molybdenum, rhodium or tungsten and filters of molybdenum, rhodium, or aluminum. In order to accommodate all these parameters, multiple extensive tables of conversion factors are required to cover the range of possibilities. Energy fluence and energy imparted are alternative measures of radiation hazard, which have been used in situations where geometry or filtration is unconventional such as computed tomography or fluoroscopy. Unfortunately, at the present there is no way to directly measure these quantities clinically. In radiation therapy applications, calorimetry has been used to measure energy absorbed. A ferroelectric-based detector has been described that measures energy fluence rate (x-ray intensity) for diagnostic x-ray, 50 to 140 kVp, aluminum filtered tungsten spectrum [Carvalho & Alter: IEEE Transactions 44(6) 1997]. This work explores use of ferroelectric detectors to measure energy fluence, energy fluence rate and energy imparted in mammography. A detector interfaced with a laptop computer was developed to allow measurements on clinical units of five different manufactures having targets of molybdenum, rhodium and tungsten and filters of molybdenum, rhodium, and aluminum of various thicknesses. The measurements provide the first values of energy fluence and energy imparted in mammography. These measurements are compared with conventional parameters such as entrance

  10. Geographic access to mammography and its relationship to breast cancer screening and stage at diagnosis: a systematic review

    PubMed Central

    Khan-Gates, Jenna A.; Ersek, Jennifer L.; Eberth, Jan M.; Adams, Swann A.; Pruitt, Sandi

    2016-01-01

    Introduction A review was conducted to summarize the current evidence and gaps in the literature on geographic access to mammography and its relationship to breast cancer-related outcomes. Methods Ovid Medline and PubMed were searched for articles published between January 1, 2000 and April 1, 2013 using Medical Subject Headings and key terms representing geographic accessibility and breast cancer-related outcomes. Due to a paucity of breast cancer treatment and mortality outcomes meeting the criteria (N=6), outcomes were restricted to breast cancer screening and stage at diagnosis. Studies included one or more of the following types of geographic accessibility measures: capacity, density, distance and travel time. Study findings were grouped by outcome and type of geographic measure. Results Twenty-one articles met inclusion criteria. Fourteen articles included stage at diagnosis as an outcome, five included mammography utilization, and two included both. Geographic measures of mammography accessibility varied widely across studies. Findings also varied, but most articles found either increased geographic access to mammography associated with increased utilization and decreased late-stage at diagnosis or no statistically significant association. Conclusion The gaps and methodologic heterogeneity in the literature to date limit definitive conclusions about an underlying association between geographic mammography access and breast cancer-related outcomes. Future studies should focus on the development and application of more precise and consistent measures of geographic access to mammography. PMID:26219677

  11. Reproducing 2D breast mammography images with 3D printed phantoms

    NASA Astrophysics Data System (ADS)

    Clark, Matthew; Ghammraoui, Bahaa; Badal, Andreu

    2016-03-01

    Mammography is currently the standard imaging modality used to screen women for breast abnormalities and, as a result, it is a tool of great importance for the early detection of breast cancer. Physical phantoms are commonly used as surrogates of breast tissue to evaluate some aspects of the performance of mammography systems. However, most phantoms do not reproduce the anatomic heterogeneity of real breasts. New fabrication technologies, such as 3D printing, have created the opportunity to build more complex, anatomically realistic breast phantoms that could potentially assist in the evaluation of mammography systems. The primary objective of this work is to present a simple, easily reproducible methodology to design and print 3D objects that replicate the attenuation profile observed in real 2D mammograms. The secondary objective is to evaluate the capabilities and limitations of the competing 3D printing technologies, and characterize the x-ray properties of the different materials they use. Printable phantoms can be created using the open-source code introduced in this work, which processes a raw mammography image to estimate the amount of x-ray attenuation at each pixel, and outputs a triangle mesh object that encodes the observed attenuation map. The conversion from the observed pixel gray value to a column of printed material with equivalent attenuation requires certain assumptions and knowledge of multiple imaging system parameters, such as x-ray energy spectrum, source-to-object distance, compressed breast thickness, and average breast material attenuation. A detailed description of the new software, a characterization of the printed materials using x-ray spectroscopy, and an evaluation of the realism of the sample printed phantoms are presented.

  12. Prevalence and Determinants of Repeat Mammography Among Women from a Developing Country.

    PubMed

    Salinas-Martínez, Ana María; Gaspar-Rivera, Jimena Estefanía; Juárez-Pérez, Oscar; Montañez-Sauceda, José Roberto; Núñez-Rocha, Georgina Mayela; Guzmán-de-la-Garza, Francisco Javier; Mathiew-Quirós, Álvaro

    2017-04-01

    Failures in repeat mammography decrease the potential benefits of screening; however, it is notable that the recent use of mammography is more frequently studied than repeat use. We estimated the prevalence and analyzed determinants for repeat mammography among women from Mexico, a developing country of Latin America. It was a two-stage study with an initial cross-sectional design (n = 1045) and a final case-control design that involved women of at least 45 years of age with no history of breast, ovarian, or uterine cancer. Case subjects were those with three or more mammograms in the last 5 years, with the last one carried out within the last two years (n = 444); control subjects included those who underwent ≥3 mammograms throughout their life with the most recent carried out >2 years ago (n = 444). Through interviews, we evaluated context-dependency, fulfillment of expected outcomes, self-efficacy, and risk perception, among other factors. We estimated the prevalence with 95 % confidence intervals (CI), and odds ratios (OR) using multivariate binary logistic regression. The prevalence of repeat mammography was 40.4 % (95 % CI 37.4-43.4). Self-efficacy demonstrated the highest effect on repeat use (OR 7.7, 95 % CI 4.7-12.6), followed by awareness context-dependency (OR 4.9, 95 % CI 3.3-7.2), the use of Papanicolaou testing (OR 3.5, 95 % CI 2.3-5.2), the fulfillment of expected waiting time outcome (OR 2.4, 95 % CI 1.2-4.7), and context-dependency related to self-referral/health provider referral (OR 2.4, 95 % CI 1.7-3.4), independent of risk perception, age, education, and positive emotional state of mind. The study showed a need for increasing the prevalence of promoting awareness of the determining factors of repeat mammography, which is a necessary component in the early detection of breast cancer.

  13. Contrast-enhanced dual-energy digital subtraction mammography: optimization of the beam energy

    NASA Astrophysics Data System (ADS)

    Kwan, Alexander L. C.; Boone, John M.; Le-Petross, Huong; Lindfors, Karen K.; Seibert, J. A.; Lewin, John M.

    2005-04-01

    The implementation of contrast-enhanced dual-energy digital subtraction mammography may lead to better identification of breast tumors, and thus provide a lower cost and more widely available alternative to breast MRI. This technique involves the acquisition of low- and high-energy images after the IV administration of iodinated contrast agent. In this study, the effect of the beam energy (kVp) was examined using the CNR2/dose metric, where CNR is the contrast-to-noise ratio and dose implies the mean glandular dose. The mean glandular dose was calculated using parameterized normalized glandular dose coefficients (DgN), which allowed the computation of the mean glandular dose for the modeled spectra considered in this study, coupled with incident kerma measurements. Optimization studies were performed using a dedicated cone-beam breast CT scanner designed and fabricated in our laboratory, with the system operating in stationary imaging mode. A flat tissue-equivalent phantom (7.5 cm in thickness) was placed at the isocenter of the scanner, and an air gap of 34.5 cm was used in lieu of a grid. Dilute iodine-based contrast agent was introduced into the phantoms using plastic vials. Data were acquired from 40 to 90 kVp at 10 kVp intervals. Due to the low mA available on the breast CT system, a large number of images (1000) were acquired in fluoroscopic mode, which allowed us to match the dose and noise properties for each kVp combinations by changing the number of images used for averaging. Preliminary results demonstrate that the best CNR2/dose is achieved with a 50 kVp low-energy image and a 90 kVp high-energy image. Consequently, radiation doses for contrast-enhanced mammography should be far lower than regular mammography. Since the spatial resolution requirements should also be lower than regular mammography, dual-energy contrast-enhanced mammography, when performed using the optimal technique factor, may indeed provide very similar diagnostic information as breast

  14. Groundwater quality data from the National Water-Quality Assessment Project, May 2012 through December 2013

    USGS Publications Warehouse

    Arnold, Terri L.; Desimone, Leslie A.; Bexfield, Laura M.; Lindsey, Bruce D.; Barlow, Jeannie R.; Kulongoski, Justin T.; Musgrove, MaryLynn; Kingsbury, James A.; Belitz, Kenneth

    2016-06-20

    Groundwater-quality data were collected from 748 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from May 2012 through December 2013. The data were collected from four types of well networks: principal aquifer study networks, which assess the quality of groundwater used for public water supply; land-use study networks, which assess land-use effects on shallow groundwater quality; major aquifer study networks, which assess the quality of groundwater used for domestic supply; and enhanced trends networks, which evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, and radionuclides. These groundwater quality data are tabulated in this report. Quality-control samples also were collected; data from blank and replicate quality-control samples are included in this report.

  15. Mammography Screening Uptake among Female Health Care Workers in Primary Health Care Centers in Palestine - Motivators and Barriers.

    PubMed

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha; Sholi, Mohammad; Lahaseh, Rawya

    2016-01-01

    Early detection remains the cornerstone of breast cancer control in terms of outcome and survival. Thus far the only breast cancer screening method proven effective is mammography. The awareness of female health care workers (HCW) about breast cancer prevention is of vital importance, as their beliefs and behavior may have a major impact on other women. This study was designed to assess mammography screening uptake among female healthcare workers at primary healthcare centers, and to identify the primary motivators and barriers that affect uptake results. A cross sectional study design was used to assess mammography screening by 299 female healthcare workers who completed a self-administered questionnaire that assessed demographics, screening uptake, motivators and barriers. The mean age was 46 years (within age of risk). The majority (95.1%) demonstrated adequate knowledge about breast cancer and mammography screening and 50% of the participants reported having at least one mammogram; however only 21% of them had regularly scheduled mammograms. The most frequent reported motivator was the perceived benefit that early detection of breast cancer is important for its management (89.6%), followed by the belief that mammography can detect breast cancer before its symptoms appear (84.4%). On the other hand, the most frequent barrier reported was being busy (46.7%), followed by the lack of perceived susceptibility (41.5%). Mammography screening was found to be sub-optimal in a population of HCW's with 50 % stating that they received a mammogram at least once, and a minority reported regular screening. There is a pressing need for educational programs aimed at removing the barriers that limit compliance with recommendations for mammography screening, and to emphasize the importance of early detection in breast cancer treatment. Ensuring the availability and accessibility of screening services, particularly for healthcare workers within their work settings are other

  16. [Extraction of management information from the national quality assurance program].

    PubMed

    Stausberg, Jürgen; Bartels, Claus; Bobrowski, Christoph

    2007-07-15

    Starting with clinically motivated projects, the national quality assurance program has established a legislative obligatory framework. Annual feedback of results is an important means of quality control. The annual reports cover quality-related information with high granularity. A synopsis for corporate management is missing, however. Therefore, the results of the University Clinics in Greifswald, Germany, have been analyzed and aggregated to support hospital management. Strengths were identified by the ranking of results within the state for each quality indicator, weaknesses by the comparison with national reference values. The assessment was aggregated per clinical discipline and per category (indication, process, and outcome). A composition of quality indicators was claimed multiple times. A coherent concept is still missing. The method presented establishes a plausible summary of strengths and weaknesses of a hospital from the point of view of the national quality assurance program. Nevertheless, further adaptation of the program is needed to better assist corporate management.

  17. Water-quality trends in the nation's rivers

    USGS Publications Warehouse

    Smith, R.A.; Alexander, R.B.; Wolman, M.G.

    1987-01-01

    Water-quality records from two nationwide sampling networks now permit nationally consistent analysis of long-term water-quality trends at more than 300 locations on major U.S. rivers. Observed trends in 24 measures of water quality for the period from 1974 to 1981 provide new insight into changes in stream quality that occurred during a time of major changes in both terrestrial and atmospheric influences on surface waters. Particularly noteworthy are widespread decreases in fecal bacteria and lead concentrations and widespread increases in nitrate, chloride, arsenic, and cadmium concentrations. Recorded increases in municipal waste treatment, use of salt on highways, and nitrogen fertilizer application, along with decreases in leaded gasoline consumption and regionally variable trends in coal production and combustion during the period appear to be reflected in water-quality changes.Water-quality records from two nationwide sampling networks now permit nationally consistent analysis of long-term water-quality trends at more than 300 locations on major U. S. rivers. Observed trends in 24 measures of water quality for the period from 1974 to 1981 provide new insight into changes in stream quality that occurred during a time of major changes in both terrestrial and atmospheric influences on surface waters. Particularly noteworthy are widespread decreases in fecal bacteria and lead concentrations and widespread increases in nitrate, chloride, arsenic, and cadmium concentrations. Recorded increases in municipal waste treatment, use of salt on highways, and nitrogen fertilizer application, along with decreases in leaded gasoline consumption and regionally variable trends in coal production and combustion during the period appear to be reflected in water-quality changes.

  18. Does National Quality Monitoring Make a Difference?

    ERIC Educational Resources Information Center

    Wahlen, Staffan

    2004-01-01

    This article analyses the impact of national quality audit of Swedish higher education institutions between 1995 and 2002. It also looks at the programme and subject reviews that have succeeded the audits, in order to compare results. It is found that the audits have resulted in the development of policy and structure of institutional quality work…

  19. Utilization of breast cancer screening methods in a developing nation: results from a nationally representative sample of Malaysian households.

    PubMed

    Dunn, Richard A; Tan, Andrew K G

    2011-01-01

    As is the case in many developing nations, previous studies of breast cancer screening behavior in Malaysia have used relatively small samples that are not nationally representative, thereby limiting the generalizability of results. Therefore, this study uses nationally representative data from the Malaysia Non-Communicable Disease Surveillance-1 to investigate the role of socio-economic status on breast cancer screening behavior in Malaysia, particularly differences in screening behaviour between ethnic groups. The decisions of 816 women above age 40 in Malaysia to screen for breast cancer using mammography, clinical breast exams (CBE), and breast self-exams (BSE) are modeled using logistic regression. Results indicate that after adjusting for differences in age, education, household income, marital status, and residential location, Malay women are less likely than Chinese and Indian women to utilize mammography, but more likely to perform BSE. Education level and urban residence are positively associated with utilization of each method, but these relationships vary across ethnicity. Higher education levels are strongly related to using each screening method among Chinese women, but have no statistically significant relationship to screening among Malays. © 2011 Wiley Periodicals, Inc.

  20. A Reconstruction Algorithm for Breast Cancer Imaging With Electrical Impedance Tomography in Mammography Geometry

    PubMed Central

    Kao, Tzu-Jen; Isaacson, David; Saulnier, Gary J.; Newell, Jonathan C.

    2009-01-01

    The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system. PMID:17405377

  1. 77 FR 69795 - Malcolm Baldrige National Quality Award Board of Overseers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    ... Quality Award Board of Overseers AGENCY: National Institute of Standards and Technology, Department of... Quality Award (Board of Overseers) will meet in open session on Wednesday, December 12, 2012. The purpose... Standards and Technology and from the Chair of the Judges' Panel of the Malcolm Baldrige National Quality...

  2. Feasibility of generating quantitative composition images in dual energy mammography: a simulation study

    NASA Astrophysics Data System (ADS)

    Lee, Donghoon; Kim, Ye-seul; Choi, Sunghoon; Lee, Haenghwa; Choi, Seungyeon; Kim, Hee-Joung

    2016-03-01

    Breast cancer is one of the most common malignancies in women. For years, mammography has been used as the gold standard for localizing breast cancer, despite its limitation in determining cancer composition. Therefore, the purpose of this simulation study is to confirm the feasibility of obtaining tumor composition using dual energy digital mammography. To generate X-ray sources for dual energy mammography, 26 kVp and 39 kVp voltages were generated for low and high energy beams, respectively. Additionally, the energy subtraction and inverse mapping functions were applied to provide compositional images. The resultant images showed that the breast composition obtained by the inverse mapping function with cubic fitting achieved the highest accuracy and least noise. Furthermore, breast density analysis with cubic fitting showed less than 10% error compare to true values. In conclusion, this study demonstrated the feasibility of creating individual compositional images and capability of analyzing breast density effectively.

  3. Medical devices; radiology devices; reclassification of full-field digital mammography system. Final rule.

    PubMed

    2010-11-05

    The Food and Drug Administration (FDA) is announcing the reclassification of the full-field digital mammography (FFDM) system from class III (premarket approval) to class II (special controls). The device type is intended to produce planar digital x-ray images of the entire breast; this generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component parts, and accessories. The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Full-Field Digital Mammography System." FDA is reclassifying the device into class II (special controls) because general controls along with special controls will provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.

  4. Validation of no-reference image quality index for the assessment of digital mammographic images

    NASA Astrophysics Data System (ADS)

    de Oliveira, Helder C. R.; Barufaldi, Bruno; Borges, Lucas R.; Gabarda, Salvador; Bakic, Predrag R.; Maidment, Andrew D. A.; Schiabel, Homero; Vieira, Marcelo A. C.

    2016-03-01

    To ensure optimal clinical performance of digital mammography, it is necessary to obtain images with high spatial resolution and low noise, keeping radiation exposure as low as possible. These requirements directly affect the interpretation of radiologists. The quality of a digital image should be assessed using objective measurements. In general, these methods measure the similarity between a degraded image and an ideal image without degradation (ground-truth), used as a reference. These methods are called Full-Reference Image Quality Assessment (FR-IQA). However, for digital mammography, an image without degradation is not available in clinical practice; thus, an objective method to assess the quality of mammograms must be performed without reference. The purpose of this study is to present a Normalized Anisotropic Quality Index (NAQI), based on the Rényi entropy in the pseudo-Wigner domain, to assess mammography images in terms of spatial resolution and noise without any reference. The method was validated using synthetic images acquired through an anthropomorphic breast software phantom, and the clinical exposures on anthropomorphic breast physical phantoms and patient's mammograms. The results reported by this noreference index follow the same behavior as other well-established full-reference metrics, e.g., the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). Reductions of 50% on the radiation dose in phantom images were translated as a decrease of 4dB on the PSNR, 25% on the SSIM and 33% on the NAQI, evidencing that the proposed metric is sensitive to the noise resulted from dose reduction. The clinical results showed that images reduced to 53% and 30% of the standard radiation dose reported reductions of 15% and 25% on the NAQI, respectively. Thus, this index may be used in clinical practice as an image quality indicator to improve the quality assurance programs in mammography; hence, the proposed method reduces the subjectivity

  5. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  6. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  7. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  8. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  9. Methodological Quality of National Guidelines for Pediatric Inpatient Conditions

    PubMed Central

    Hester, Gabrielle; Nelson, Katherine; Mahant, Sanjay; Eresuma, Emily; Keren, Ron; Srivastava, Rajendu

    2014-01-01

    Background Guidelines help inform standardization of care for quality improvement (QI). The Pediatric Research in Inpatient Settings (PRIS) network published a prioritization list of inpatient conditions with high prevalence, cost, and variation in resource utilization across children’s hospitals. The methodological quality of guidelines for priority conditions is unknown. Objective To rate the methodological quality of national guidelines for 20 priority pediatric inpatient conditions. Design We searched sources including PubMed for national guidelines published 2002–2012. Guidelines specific to one organism, test or treatment, or institution were excluded. Guidelines were rated by two raters using a validated tool (AGREE II) with an overall rating on a 7-point scale (7–highest). Inter-rater reliability was measured with a weighted kappa coefficient. Results 17 guidelines met inclusion criteria for 13 conditions, 7 conditions yielded no relevant national guidelines. The highest methodological quality guidelines were for asthma, tonsillectomy, and bronchiolitis (mean overall rating 7, 6.5 and 6.5 respectively); the lowest were for sickle cell disease (2 guidelines) and dental caries (mean overall rating 4, 3.5, and 3 respectively). The overall weighted kappa was 0.83 (95% confidence interval 0.78–0.87). Conclusions We identified a group of moderate to high methodological quality national guidelines for priority pediatric inpatient conditions. Hospitals should consider these guidelines to inform QI initiatives. PMID:24677729

  10. Degree of Enhancement on Contrast Enhanced Spectral Mammography (CESM) and Lesion Type on Mammography (MG): Comparison Based on Histological Results

    PubMed Central

    Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz

    2016-01-01

    Background Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. Material/Methods The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. Results Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). Conclusions Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions. PMID:27768681

  11. Degree of Enhancement on Contrast Enhanced Spectral Mammography (CESM) and Lesion Type on Mammography (MG): Comparison Based on Histological Results.

    PubMed

    Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz

    2016-10-21

    BACKGROUND Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. MATERIAL AND METHODS The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. RESULTS Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). CONCLUSIONS Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions.

  12. Quality Management Systems for the National Qualifications Framework. Quality Assurance in Education and Training.

    ERIC Educational Resources Information Center

    New Zealand Qualifications Authority, Wellington.

    This booklet explores the idea of quality and its management as it applies to providers of education in particular, but also as it applies to national standards bodies and workplaces offering on-the-job training. It explores the focus on quality in industry and education and defines quality in terms of the features of quality and their…

  13. Visualizing the Diffusion of Digital Mammography in New York State.

    PubMed

    Boscoe, Francis P; Zhang, Xiuling

    2017-04-01

    Background: Digital mammography saw rapid adoption during the first decade of the 2000s. We were interested in identifying the times and locations where the technology was introduced within the state of New York as a way of illustrating the uneven introduction of this technology. Methods: Using a sample of Medicare claims data from the period 2004 to 2012 from women ages 65 and over without cancer, we calculated the percentage of mammograms that were digital by zip code of residence and illustrated them with a series of smoothed maps. Results: Maps for three of the years (2005, 2008, and 2011) show the conversion from almost no digital mammography to nearly all digital mammography. The 2008 map reveals sharp disparities between areas that had and had not yet adopted the technology. Socioeconomic differences explain some of this pattern. Conclusions: Geographic disparities in access to medical technology are underappreciated relative to other sources of disparities. Our method provides a way of measuring and communicating this phenomenon. Impact: Our method could be applied to illuminate current examples, where access to medical technology is highly uneven, such as 3D tomography and robotic surgery. Cancer Epidemiol Biomarkers Prev; 26(4); 490-4. ©2017 AACR See all the articles in this CEBP Focus section, "Geospatial Approaches to Cancer Control and Population Sciences." ©2017 American Association for Cancer Research.

  14. 77 FR 9651 - National Advisory Committee on Institutional Quality and Integrity (NACIQI) Teleconference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-17

    ... DEPARTMENT OF EDUCATION National Advisory Committee on Institutional Quality and Integrity (NACIQI) Teleconference AGENCY: National Advisory Committee on Institutional Quality and Integrity, Office of... teleconference meeting of the National Advisory Committee on Institutional Quality and Integrity (NACIQI) and...

  15. Digital mammography: physical principles and future applications.

    PubMed

    Gambaccini, Mauro; Baldelli, Paola

    2003-01-01

    Mammography is currently considered the best tool for the detection of breast cancer, pathology with a rate of incidence in constant increase. To produce the radiological picture a screen film combination is conventionally used. One of the inherent limitations of screen- film combination is the fact that the detection, display and storage processes are one and the same, making it impossible to separately optimize each stage. These limitations can be overcome with digital systems. In this work we evaluate the main characteristics of digital detectors available on the market and we compare the performance of digital and conventional systems. Digital mammography, due to the possibility to process images, offers many potential advantages, among these the possibility to introduce the dual-energy technique which employs the composition of two digital images obtained with two different energies to enhance the inherent contrast of pathologies by removing the uniform background. This technique was previously tested by using synchrotron monochromatic beam and a digital detector, and then the Senographe 2000D full-field digital system manufactured by GE Medical Systems. In this work we present preliminary results and the future applications of this technique.

  16. Contrast-to-noise ratio in magnification mammography: a Monte Carlo study

    NASA Astrophysics Data System (ADS)

    Koutalonis, M.; Delis, H.; Spyrou, G.; Costaridou, L.; Tzanakos, G.; Panayiotakis, G.

    2007-06-01

    Magnification views are a common way to perform a secondary examination when suspicious abnormalities are found in a screening mammogram. The visibility of microcalcifications and breast lesions is restricted by the compromise between the image quality and the absorbed dose. In this study, image quality characteristics in magnification mammography were evaluated based on Monte Carlo techniques. A breast phantom was utilized, simulating a homogeneous mixture of adipose and glandular tissue in various percentages of glandularity, containing inhomogeneities of various sizes and compositions. The effect of the magnification degree, breast glandularity, tube voltage and anode/filter material combination on image quality characteristics was investigated in terms of a contrast-to-noise ratio (CNR). A performance index PIν was introduced in order to study the overall performance of various anode/filter combinations under different exposure parameters. Results demonstrate that CNR is improved with the degree of magnification and degraded as the breast glandularity is increased. Degree of magnification 1.3 offers the best overall performance for most of the anode/filter combinations utilized. Under magnification conditions, the role of dose is demoted against the image quality, as magnification views are secondary, diagnostic examinations and not screening procedures oriented to non-symptomatic women. For decreased image quality weighting, some anode/filter combinations different from Mo/0.030mmMo can be utilized as they offer a similar performance index. However, if the desired weighting for the image quality is high, the Mo/0.030mmMo combination has the best overall performance.

  17. Overview of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Leahy, P.P.; Thompson, T.H.

    1994-01-01

    The Nation's water resources are the basis for life and our economic vitality. These resources support a complex web of human activities and fishery and wildlife needs that depend upon clean water. Demands for good-quality water for drinking, recreation, farming, and industry are rising, and as a result, the American public is concerned about the condition and sustainability of our water resources. The American public is asking: Is it safe to swim in and drink water from our rivers or lakes? Can we eat the fish that come from them? Is our ground water polluted? Is water quality degrading with time, and if so, why? Has all the money we've spent to clean up our waters, done any good? The U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program was designed to provide information that will help answer these questions. NAWQA is designed to assess historical, current, and future water-quality conditions in representative river basins and aquifers nationwide. One of the primary objectives of the program is to describe relations between natural factors, human activities, and water-quality conditions and to define those factors that most affect water quality in different parts of the Nation. The linkage of water quality to environmental processes is of fundamental importance to water-resource managers, planners, and policy makers. It provides a strong and unbiased basis for better decisionmaking by those responsible for making decisions that affect our water resources, including the United States Congress, Federal, State, and local agencies, environmental groups, and industry. Information from the NAWQA Program also will be useful for guiding research, monitoring, and regulatory activities in cost effective ways.

  18. Competitive testing of health behavior theories: how do benefits, barriers, subjective norm, and intention influence mammography behavior?

    PubMed Central

    Murphy, Caitlin C.; Vernon, Sally W.; Diamond, Pamela M.; Tiro, Jasmin A.

    2013-01-01

    Background Competitive hypothesis testing may explain differences in predictive power across multiple health behavior theories. Purpose We tested competing hypotheses of the Health Belief Model (HBM) and Theory of Reasoned Action (TRA) to quantify pathways linking subjective norm, benefits, barriers, intention, and mammography behavior. Methods We analyzed longitudinal surveys of women veterans randomized to the control group of a mammography intervention trial (n=704). We compared direct, partial mediation, and full mediation models with Satorra-Bentler χ2 difference testing. Results Barriers had a direct and indirect negative effect on mammography behavior; intention only partially mediated barriers. Benefits had little to no effect on behavior and intention; however, it was negatively correlated with barriers. Subjective norm directly affected behavior and indirectly affected intention through barriers. Conclusions Our results provide empiric support for different assertions of HBM and TRA. Future interventions should test whether building subjective norm and reducing negative attitudes increases regular mammography. PMID:23868613

  19. Light sensitometry of mammography films at varying development temperatures and times

    PubMed Central

    Sharma, Reena; Sharma, Sunil Dutt; Mayya, Y. S.

    2012-01-01

    Kodak MinR-2000 mammography film is widely used for mammography imaging. The sensitometric indices like base plus fog level (B + F), maximum optical density (ODmax), average gradient (AG) and speed of this film at varying development temperatures and times were evaluated using a light sensitometer. Totally 33 film strips were cut from a single Kodak MinR-2000 mammography film box and exposed in a light sensitometer operated in the green light spectrum to produce a 21-step sensitometric strip. These exposed film strips were processed at temperatures in the range of 32°C–37°C in the step of 1°C and at processing times in the range of 1–6 minutes in the step of 1 minute. The results of the present study show that the measured base plus fog level of the mammography film was not affected much, whereas significant changes were seen in the ODmax, AG and speed with varying development temperatures and times. The ODmax values of the film were found in the range of 3.67–3.76, AG values were in the range of 2.48–3.4 and speed values were in the range of 0.015–0.0236 when the processing temperature was varied from 32°C to 37°C. With processing time variation from 1 to 6 minutes, the observed changes in ODmax values were in the range of 3.54-3.71, changes in AG were in the range of 2.66–3.27 and changes in speed were in the range of 0.011–0.025. Based on these observations, recommendations for optimum processing parameters to be used for this film are made. PMID:22363111

  20. Educational interventions to improve screening mammography interpretation: a randomized, controlled trial

    PubMed Central

    BM, Geller; A, Bogart; PA, Carney; EA, Sickles; RA, Smith; B, Monsees; LW, Bassett; DM, Buist; K, Kerlikowske; T, Onega; B, Yankaskas; S, Haneuse; DA, Hill; M, Wallis; DL, Miglioretti

    2014-01-01

    Purpose Conduct a randomized controlled trial of educational interventions to improve performance of screening mammography interpretation. Materials and Methods We randomly assigned physicians who interpret mammography to one of three groups: (1) self-paced DVD; (2) live, expert-led educational session; or (3) control. The DVD and live interventions used mammography cases of varying difficulty and associated teaching points. Interpretive performance was compared using a pre-/post-test design. Sensitivity, specificity, and positive predictive value (PPV) were calculated relative to two outcomes: cancer status and consensus of three experts about recall, and each were compared using logistic regression adjusting for pre-test performance. Results 102 radiologists completed all aspects of the trial. After adjustment for pre-intervention performance, the odds of improved sensitivity for correctly identifying a lesion relative to expert recall were 1.34 times higher for DVD participants than controls (95% confidence interval [CI]: 1.00, 1.81; P=0.050). The odds of improved PPV for correctly identifying a lesion relative to both expert recall (odds ratio [OR]=1.94, 95% CI: 1.24, 3.05; P=0.004) and cancer status (OR=1.81, 95% CI: 1.01, 3.23; P=0.045) were significantly improved for DVD participants compared to controls with no significant change in specificity. For the live-intervention group, specificity was significantly lower than the control group (OR relative to expert recall=0.80; 95% CI: 0.64, 1.00; P=0.048; OR relative to cancer=0.79; 95% CI: 0.65, 0.95; P=0.015). Conclusion In this randomized controlled trial, the DVD educational intervention resulted in a significant improvement in mammography interpretive screening performance on a test-set, which could translate into improved clinical interpretative performance. PMID:24848854

  1. Educational interventions to improve screening mammography interpretation: a randomized controlled trial.

    PubMed

    Geller, Berta M; Bogart, Andy; Carney, Patricia A; Sickles, Edward A; Smith, Robert; Monsees, Barbara; Bassett, Lawrence W; Buist, Diana M; Kerlikowske, Karla; Onega, Tracy; Yankaskas, Bonnie C; Haneuse, Sebastien; Hill, Deirdre; Wallis, Matthew G; Miglioretti, Diana

    2014-06-01

    The objective of our study was to conduct a randomized controlled trial of educational interventions that were created to improve performance of screening mammography interpretation. We randomly assigned physicians who interpret mammography to one of three groups: self-paced DVD, live expert-led educational seminar, or control. The DVD and seminar interventions used mammography cases of varying difficulty and provided associated teaching points. Interpretive performance was compared using a pretest-posttest design. Sensitivity, specificity, and positive predictive value (PPV) were calculated relative to two outcomes: cancer status and consensus of three experts about recall. The performance measures for each group were compared using logistic regression adjusting for pretest performance. One hundred two radiologists completed all aspects of the trial. After adjustment for preintervention performance, the odds of improved sensitivity for correctly identifying a lesion relative to expert recall were 1.34 times higher for DVD participants than for control subjects (95% CI, 1.00-1.81; p = 0.050). The odds of an improved PPV for correctly identifying a lesion relative to both expert recall (odds ratio [OR] = 1.94; 95% CI, 1.24-3.05; p = 0.004) and cancer status (OR = 1.81; 95% CI, 1.01-3.23; p = 0.045) were significantly improved for DVD participants compared with control subjects, with no significant change in specificity. For the seminar group, specificity was significantly lower than the control group (OR relative to expert recall = 0.80; 95% CI, 0.64-1.00; p = 0.048; OR relative to cancer status = 0.79; 95% CI, 0.65-0.95; p = 0.015). In this randomized controlled trial, the DVD educational intervention resulted in a significant improvement in screening mammography interpretive performance on a test set, which could translate into improved interpretative performance in clinical practice.

  2. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jallow, N; Sechopoulos, I

    2016-06-15

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulationmore » of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.« less

  3. Benefits, harms, and costs for breast cancer screening after US implementation of digital mammography.

    PubMed

    Stout, Natasha K; Lee, Sandra J; Schechter, Clyde B; Kerlikowske, Karla; Alagoz, Oguzhan; Berry, Donald; Buist, Diana S M; Cevik, Mucahit; Chisholm, Gary; de Koning, Harry J; Huang, Hui; Hubbard, Rebecca A; Miglioretti, Diana L; Munsell, Mark F; Trentham-Dietz, Amy; van Ravesteyn, Nicolien T; Tosteson, Anna N A; Mandelblatt, Jeanne S

    2014-06-01

    Compared with film, digital mammography has superior sensitivity but lower specificity for women aged 40 to 49 years and women with dense breasts. Digital has replaced film in virtually all US facilities, but overall population health and cost from use of this technology are unclear. Using five independent models, we compared digital screening strategies starting at age 40 or 50 years applied annually, biennially, or based on density with biennial film screening from ages 50 to 74 years and with no screening. Common data elements included cancer incidence and test performance, both modified by breast density. Lifetime outcomes included mortality, quality-adjusted life-years, and screening and treatment costs. For every 1000 women screened biennially from age 50 to 74 years, switching to digital from film yielded a median within-model improvement of 2 life-years, 0.27 additional deaths averted, 220 additional false-positive results, and $0.35 million more in costs. For an individual woman, this translates to a health gain of 0.73 days. Extending biennial digital screening to women ages 40 to 49 years was cost-effective, although results were sensitive to quality-of-life decrements related to screening and false positives. Targeting annual screening by density yielded similar outcomes to targeting by age. Annual screening approaches could increase costs to $5.26 million per 1000 women, in part because of higher numbers of screens and false positives, and were not efficient or cost-effective. The transition to digital breast cancer screening in the United States increased total costs for small added health benefits. The value of digital mammography screening among women aged 40 to 49 years depends on women's preferences regarding false positives. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  4. TU-A-18C-01: ACR Accreditation Updates in CT, Ultrasound, Mammography and MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R; Berns, E; Hangiandreou, N

    2014-06-15

    A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, the ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-datemore » as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, mammography, ultrasound, and computed tomography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program. To understand the new requirements of the ACR ultrasound accreditation program, and roles the physicist can play in annual equipment surveys and setting up and supervising the routine QC program. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process.« less

  5. National Quality Measures for Child Mental Health Care: Background, Progress, and Next Steps

    PubMed Central

    Murphy, J. Michael; Scholle, Sarah Hudson; Hoagwood, Kimberly Eaton; Sachdeva, Ramesh C.; Mangione-Smith, Rita; Woods, Donna; Kamin, Hayley S.; Jellinek, Michael

    2013-01-01

    OBJECTIVE: To review recent health policies related to measuring child health care quality, the selection processes of national child health quality measures, the nationally recommended quality measures for child mental health care and their evidence strength, the progress made toward developing new measures, and early lessons learned from these national efforts. METHODS: Methods used included description of the selection process of child health care quality measures from 2 independent national initiatives, the recommended quality measures for child mental health care, and the strength of scientific evidence supporting them. RESULTS: Of the child health quality measures recommended or endorsed during these national initiatives, only 9 unique measures were related to child mental health. CONCLUSIONS: The development of new child mental health quality measures poses methodologic challenges that will require a paradigm shift to align research with its accelerated pace. PMID:23457148

  6. Influence of Demographic Factors, Knowledge, and Beliefs on Jordanian Women’s Intention to Undergo Mammography Screening

    PubMed Central

    Othman, Areej K.; Kiviniemi, Marc T.; Wu, Yow-Wu B.; Lally, Robin M.

    2013-01-01

    Purpose The purpose of this study was to determine the influence of demographic characteristics, breast cancer knowledge, fatalistic beliefs, health beliefs, and subjective norms on Jordanian women’s intention to participate in mammography screening. Design A cross-sectional survey was used to collect data at 14 comprehensive healthcare centers in Amman and Zarqa, Jordan. A convenience sample of 142 Jordanian women 40 years of age or older with no history of breast cancer and able to read and write in Arabic participated. Methods Self-report surveys included a combination of researcher-designed and existing instruments to measure the study variables. Data were analyzed using descriptive statistics, Pearson’s correlation, t tests, and multiple logistic regression. Findings Jordanian women surveyed lacked knowledge about breast cancer. Social norms and self-efficacy highly influenced these women’s intention to engage in mammography screening. Younger women were more willing to indicate intention to engage in mammographic screening. Conclusions Self-efficacy and the social connectedness of Jordanian society, but not religious beliefs or perceived barriers to screening, influence Jordanian women’s intention to undergo mammography. Future research should examine cultural influences, rather than religious beliefs, and investigate Jordanian women’s potentially unique perspectives on barriers to actual mammography screening behavior. Clinical Relevance The prevalence of mammography screening may be enhanced by focusing interventions on Jordanian women’s support systems and empowering women by providing knowledge and skills needed to engage in the procedure. PMID:22339890

  7. A brief nursing intervention reduces anxiety before breast cancer screening mammography.

    PubMed

    Fernández-Feito, Ana; Lana, Alberto; Baldonedo-Cernuda, Ricardo; Mosteiro-Díaz, María Pilar

    2015-01-01

    Anxiety experienced by women during their participation in breast cancer screening programs can condition their adherence to the program. The aim was to determine whether a brief nursing intervention could reduce anxiety before screening mammography. A randomized controlled trial carried out with 436 Spanish women aged between 50-69 years, who attended a population breast cancer screening program. The experimental group received an ad-hoc tailored intervention, which consisted of offering information about the screening program and the mammography exam, as well as of providing personal emotional support. Anxiety was assessed using the State-Trait Anxiety Inventory (STAI). Fear of screening outcome and fear of breast cancer were also assessed. Women of the experimental group had 60% less probability of having a high anxiety state (OR = 0.40; 95%: CI [0.25, 0.65]), after adjusting for sociodemographic and clinical variables. Regarding trait anxiety, no differences were observed between groups. The stratified analysis showed that this positive impact was greater in women who did not fear the screening outcome (OR = 0.24; 95% CI [0.11, 0.52]) or breast cancer (OR = 0.07; 95% CI [0.01, 0.41]). A protocolized nursing intervention reduced the probability of being anxious when undergoing a screening mammography.

  8. Decision-Making Regarding Mammography Screening for Older Women.

    PubMed

    Schonberg, Mara A

    2016-12-01

    The population is aging, and breast cancer incidence increases with age, peaking between the ages of 75 and 79. However, it is not known whether mammography screening helps women aged 75 and older live longer because they have not been included in randomized controlled trials evaluating mammography screening. Guidelines recommend that older women with less than a 10-year life expectancy not be screened because it takes approximately 10 years before a screen-detected breast cancer may affect an older woman's survival. Guidelines recommend that clinicians discuss the benefits and risks of screening with women aged 75 and older with a life expectancy of 10 years or longer to help them elicit their values and preferences. It is estimated that two of 1,000 women who continue to be screened every other year from age 70 to 79 may avoid breast cancer death, but 12% to 27% of these women will experience a false-positive test, and 10% to 20% of women who experience a false-positive test will undergo a breast biopsy. In addition, approximately 30% of screen-detected cancers would not otherwise have shown up in an older woman's lifetime, yet nearly all older women undergo treatment for these breast cancers, and the risks of treatment increase with age. To inform decision-making, tools are available to estimate life expectancy and to educate older women about the benefits and harms of mammography screening. Guides are also available to help clinicians discuss stopping screening with older women with less than a 10-year life expectancy. Ideally, screening decisions would consider an older woman's life expectancy, breast cancer risk, and her values and preferences. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  9. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging.

    PubMed

    Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.

  10. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging

    PubMed Central

    Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107

  11. Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease.

    PubMed

    Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita

    2017-11-01

    Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P < .001 for all results). In addition, contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of

  12. Assessment of Mammography Experiences and Satisfaction among American Indian/Alaska Native Women

    PubMed Central

    Ndikum-Moffor, Florence M.; Braiuca, Stacy; Daley, Christine Makosky; Gajewski, Byron J.; Engelman, Kimberly K.

    2013-01-01

    BACKGROUND American Indian/Alaska Native (AI/AN) women have lower breast cancer (BCA) screening and 5-year survival rates than non-Hispanic Whites. Understanding reasons for low screening rates is important to combat later stage diagnoses. The purpose of this study was to assess mammography experiences and satisfaction among AI/AN women. METHODS Nine focus groups were held with rural (N=15) and urban (N=38) AI/AN women 40 years and older in Kansas and Kansas City, Missouri, living both near and far from Indian Health Service (IHS) and tribal facilities, to examine experiences and satisfaction with mammography. Transcripts were coded and themes identified using a community-based participatory research approach. FINDINGS Themes were classified under knowledge, communication, and awareness of breast cancer, barriers to mammography, mammogram facility size, impressions of mammogram technologist, motivations to getting a mammogram, and how to improve the mammogram experience. Participants had knowledge of prevention, but described cultural reasons for not discussing it and described better experiences in smaller facilities. Participants indicated having a mammogram technologist who was friendly, knowledgeable, respectful, competent, and explained the test was a determining factor in satisfaction. Other factors included family history, physician recommendation, and financial incentives. Barriers included transportation, cost, perceptions of prejudice, and time constraints. Participants on reservations or near IHS facilities preferred IHS over mainstream providers. Suggestions for improvement included caring technologists, better machines with less discomfort, and education. CONCLUSIONS Interventions to enhance the professionalism, empathy, and cultural awareness of mammogram technologists, reduce barriers, and provide positive expectations and incentives could improve satisfaction and compliance with screening mammography. PMID:24183414

  13. Slot scanning versus antiscatter grid in digital mammography: comparison of low-contrast performance using contrast-detail measurement

    NASA Astrophysics Data System (ADS)

    Lai, Chao-Jen; Shaw, Chris C.; Geiser, William; Kappadath, Srinivas C.; Liu, Xinming; Wang, TianPeng; Tu, Shu-Ju; Altunbas, Mustafa C.

    2004-05-01

    Slot scanning imaging techniques allow for effective scatter rejection without attenuating primary x-rays. The use of these techniques should generate better image quality for the same mean glandular dose (MGD) or a similar image quality for a lower MGD as compared to imaging techniques using an anti-scatter grid. In this study, we compared a slot scanning digital mammography system (SenoScan, Fisher Imaging Systems, Denver, CO) to a full-field digital mammography (FFDM) system used in conjunction with a 5:1 anti-scatter grid (SenoGraphe 2000D, General Electric Medical Systems, Milwaukee, WI). Images of a contrast-detail phantom (University Hospital Nijmegen, The Netherlands) were reviewed to measure the contrast-detail curves for both systems. These curves were measured at 100%, 71%, 49% and 33% of the reference mean glandular dose (MGD), as determined by photo-timing, for the Fisher system and 100% for the GE system. Soft-copy reading was performed on review workstations provided by the manufacturers. The correct observation ratios (CORs) were also computed and used to compare the performance of the two systems. The results showed that, based on the contrast-detail curves, the performance of the Fisher images, acquired at 100% and 71% of the reference MGD, was comparable to the GE images at 100% of the reference MGD. The CORs for Fisher images were 0.463 and 0.444 at 100% and 71% of the reference MGD, respectively, compared to 0.453 for the GE images at 100% of the reference MGD.

  14. Mammography screening trends: the perspective of African American women born pre/post World War II.

    PubMed

    Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A

    2010-06-01

    Researchers have traditionally combined aging women (aged > or =50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non-baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non-baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947-0.968) cohort effects may have partially reversed the age effect, with non-baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278-2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population.

  15. The ACA's Zero Cost-Sharing Mandate and Trends in Out-of-Pocket Expenditures on Well-Child and Screening Mammography Visits.

    PubMed

    Kirby, James B; Davidoff, Amy J; Basu, Jayasree

    2016-12-01

    Starting in September of 2010, the Patient Protection and Affordable Care Act required most health insurance policies to cover evidence-based preventive care with no cost-sharing (no copays, coinsurance, or deductibles). It is unknown, however, whether declines in out-of-pocket costs for preventive services are large enough to prompt increases in utilization, the ultimate goal of the policy. In this study, we use a nationally representative sample of ambulatory care visits to estimate the impact of the zero cost-sharing mandate on out-of-pocket expenditures on well-child and screening mammography visits. Estimates are made using 2-part interrupted time-series models, with well-woman visits serving as the control group because they were not covered under the zero cost-sharing mandate until after our study period. Results indicate a substantial reduction in out-of-pocket costs attributable to the Affordable Care Act. Between January 2011 and September 2012, the zero cost-sharing mandate reduced per-visit out-of-pocket costs for well-child visits from $18.46 to $8.08 (56%) and out-of-pocket costs for screening mammography visits from $25.43 to $6.50 (74%). No reduction was apparent for well-woman visits. The Affordable Care Act's zero cost-sharing mandate for preventive care has had a large impact on out-of-pocket expenditures for well-child and mammography visits. To increase preventive service use, research is needed to better understand barriers to obtaining preventive care that are not directly related to cost.

  16. National Water-Quality Assessment Program; the Allegheny-Monongahela River Basin

    USGS Publications Warehouse

    McAuley, Steven D.

    1995-01-01

    In 1991, the U.S. Geological Survey (USGS) began a National Water-Quality Assessment (NAWQA) program. The three major objectives of the NAWQA program are to provide a consistent description of current water-quality conditions for a large part of the Nation's water resources, define long-term trends in water quality, and identify, describe, and explain the major factors that affect water-quality conditions and trends. The program produces water-quality information that is useful to policy makers and managers at the National, State, and local levels.The program will be implemented through 60 separate investigations of river basins and aquifer systems called study units. These study-unit investigations will be conducted at the State and local level and will form the foundation on which national- and regional-level assessments are based. The 60 study units are hydrologic systems that include parts of most major river basins and aquifer systems. The study-unit areas range from 1,000 to more than 60,000 square miles and include about 60 to 70 percent of the Nation's water use and population served by public water supplies. Twenty studyunit investigations were started in 1991, 20 started in 1994, and 20 more are planned to start in 1997. The Allegheny-Monongahela River Basin was selected to begin assessment activities as a NAWQA study unit in 1994. The study team will work from the office of the USGS in Pittsburgh, Pa.

  17. Accuracy of Physical Examination, Ultrasonography, and Mammography in Predicting Residual Pathologic Tumor Size in Patients Treated With Neoadjuvant Chemotherapy

    PubMed Central

    Chagpar, Anees B.; Middleton, Lavinia P.; Sahin, Aysegul A.; Dempsey, Peter; Buzdar, Aman U.; Mirza, Attiqa N.; Ames, Fredrick C.; Babiera, Gildy V.; Feig, Barry W.; Hunt, Kelly K.; Kuerer, Henry M.; Meric-Bernstam, Funda; Ross, Merrick I.; Singletary, S Eva

    2006-01-01

    Objective: To assess the accuracy of physical examination, ultrasonography, and mammography in predicting residual size of breast tumors following neoadjuvant chemotherapy. Background: Neoadjuvant chemotherapy is an accepted part of the management of stage II and III breast cancer. Accurate prediction of residual pathologic tumor size after neoadjuvant chemotherapy is critical in guiding surgical therapy. Although physical examination, ultrasonography, and mammography have all been used to predict residual tumor size, there have been conflicting reports about the accuracy of these methods in the neoadjuvant setting. Methods: We reviewed the records of 189 patients who participated in 1 of 2 protocols using doxorubicin-containing neoadjuvant chemotherapy, and who had assessment by physical examination, ultrasonography, and/or mammography no more than 60 days before their surgical resection. Size correlations were performed using Spearman rho analysis. Clinical and pathologic measurements were also compared categorically using the weighted kappa statistic. Results: Size estimates by physical examination, ultrasonography, and mammography were only moderately correlated with residual pathologic tumor size after neoadjuvant chemotherapy (correlation coefficients: 0.42, 0.42, and 0.41, respectively), with an accuracy of ±1 cm in 66% of patients by physical examination, 75% by ultrasonography, and 70% by mammography. Kappa values (0.24–0.35) indicated poor agreement between clinical and pathologic measurements. Conclusion: Physical examination, ultrasonography, and mammography were only moderately useful for predicting residual pathologic tumor size after neoadjuvant chemotherapy. PMID:16432360

  18. National Water Quality Laboratory, 1995 services catalog

    USGS Publications Warehouse

    Timme, P.J.

    1995-01-01

    This Services Catalog contains information about field supplies and analytical services available from the National Water Quality Laboratory in Denver, Colo., and field supplies available from the Quality Water Service Unit in Ocala, Fla., to members of the U.S. Geological Survey. To assist personnel in the selection of analytical services, this catalog lists sample volume, required containers, applicable concentration range, detection level, precision of analysis, and preservation requirements for samples.

  19. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false National primary ambient air quality standards for carbon monoxide. 50.8 Section 50.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for...

  20. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false National primary ambient air quality standards for carbon monoxide. 50.8 Section 50.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for...

  1. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false National primary ambient air quality standards for carbon monoxide. 50.8 Section 50.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for...

  2. Breast Radiation Dose With CESM Compared With 2D FFDM and 3D Tomosynthesis Mammography.

    PubMed

    James, Judy R; Pavlicek, William; Hanson, James A; Boltz, Thomas F; Patel, Bhavika K

    2017-02-01

    We aimed to compare radiation dose received during contrast-enhanced spectral mammography (CESM) using high- and low-energy projections with radiation dose received during 2D full field digital mammography (FFDM) and 3D tomosynthesis on phantoms and patients with varying breast thickness and density. A single left craniocaudal projection was chosen to determine the doses for 6214 patients who underwent 2D FFDM, 3662 patients who underwent 3D tomosynthesis, and 173 patients who underwent CESM in this retrospective study. Dose measurements were also collected in phantoms with composition mimicking nondense and dense breast tissue. Average glandular dose (AGD) ± SD was 3.0 ± 1.1 mGy for CESM exposures at a mean breast thickness of 63 mm. At this thickness, the dose was 2.1 mGy from 2D FFDM and 2.5 mGy from 3D tomosynthesis. The nondense phantom had a mean AGD of 1.0 mGy with 2D FFDM, 1.3 mGy with 3D tomosynthesis, and 1.6 mGy with CESM. The dense breast phantom had a mean AGD of 1.3 mGy with 2D FFDM, 1.4 mGy with 3D tomosynthesis, and 2.1 mGy with CESM. At a compressed thickness of 4.5 cm, radiation exposure from CESM was approximately 25% higher in dense breast phantoms than in nondense breast phantoms. The dose in the dense phantom at a compressed thickness of 6 cm was approximately 42% higher than the dose in the nondense phantom at a compressed thickness of 4.5 cm. CESM was found to increase AGD at a mean breast thickness of 63 mm by approximately 0.9 mGy and 0.5 mGy compared with 2D FFDM and 3D tomosynthesis, respectively. Of note, CESM provides a standard image (similar to 2D FFDM) that is obtained using the low-energy projection. Overall, the AGD from CESM falls below the dose limit of 3 mGy set by Mammography Quality Standards Act regulations.

  3. A randomized trial of three videos that differ in the framing of information about mammography in women 40 to 49 years old.

    PubMed

    Lewis, Carmen L; Pignone, Michael P; Sheridan, Stacey L; Downs, Stephen M; Kinsinger, Linda S

    2003-11-01

    To assess the effect of providing structured information about the benefits and harms of mammography in differing frames on women's perceptions of screening. Randomized control trial. General internal medicine academic practice. One hundred seventy-nine women aged 35 through 49. Women received 1 of 3 5-minute videos about the benefits and harms of screening mammography in women aged 40 to 49. These videos differed only in the way the probabilities of potential outcomes were framed (positive, neutral, or negative). We measured the change in accurate responses to questions about potential benefits and harms of mammography, and the change in the proportion of participants who perceived that the benefits of mammography were more important than the harms. Before seeing the videos, women's knowledge about the benefits and harms of mammography was inaccurate (82% responded incorrectly to all 3 knowledge questions). After seeing the videos, the proportion that answered correctly increased by 52%, 43%, and 30% for the 3 knowledge questions, respectively, but there were no differences between video frames. At baseline, most women thought the benefits of mammography outweighed the harms (79% positive frame, 80% neutral frame, and 85% negative frame). After the videos, these proportions were similar among the 3 groups (84%, 81%, 83%, P =.93). Women improved the accuracy of their responses to questions about the benefits and harms of mammography after seeing the videos, but this change was not affected by the framing of information. Women strongly perceived that the benefits of mammography outweighed the harms, and providing accurate information had no effect on these perceptions, regardless of how it was framed.

  4. Wavelet processing techniques for digital mammography

    NASA Astrophysics Data System (ADS)

    Laine, Andrew F.; Song, Shuwu

    1992-09-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Similar to traditional coarse to fine matching strategies, the radiologist may first choose to look for coarse features (e.g., dominant mass) within low frequency levels of a wavelet transform and later examine finer features (e.g., microcalcifications) at higher frequency levels. In addition, features may be extracted by applying geometric constraints within each level of the transform. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet representations, enhanced by linear, exponential and constant weight functions through scale space. By improving the visualization of breast pathology we can improve the chances of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  5. National Standards for Quality Online Courses: Version 2

    ERIC Educational Resources Information Center

    International Association for K-12 Online Learning, 2011

    2011-01-01

    The mission of the International Association for K-12 Online Learning (iNACOL) is to ensure all students have access to world-class education and quality online learning opportunities that prepare them for a lifetime of success. "National Standards for Quality Online Courses" is designed to provide states, districts, online programs, and…

  6. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    NASA Astrophysics Data System (ADS)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  7. An ensemble-based approach for breast mass classification in mammography images

    NASA Astrophysics Data System (ADS)

    Ribeiro, Patricia B.; Papa, João. P.; Romero, Roseli A. F.

    2017-03-01

    Mammography analysis is an important tool that helps detecting breast cancer at the very early stages of the disease, thus increasing the quality of life of hundreds of thousands of patients worldwide. In Computer-Aided Detection systems, the identification of mammograms with and without masses (without clinical findings) is highly needed to reduce the false positive rates regarding the automatic selection of regions of interest that may contain some suspicious content. In this work, the introduce a variant of the Optimum-Path Forest (OPF) classifier for breast mass identification, as well as we employed an ensemble-based approach that can enhance the effectiveness of individual classifiers aiming at dealing with the aforementioned purpose. The experimental results also comprise the naïve OPF and a traditional neural network, being the most accurate results obtained through the ensemble of classifiers, with an accuracy nearly to 86%.

  8. Randomized trial of a lay health advisor and computer intervention to increase mammography screening in African American women.

    PubMed

    Russell, Kathleen M; Champion, Victoria L; Monahan, Patrick O; Millon-Underwood, Sandra; Zhao, Qianqian; Spacey, Nicole; Rush, Nathan L; Paskett, Electra D

    2010-01-01

    Low-income African American women face numerous barriers to mammography screening. We tested the efficacy of a combined interactive computer program and lay health advisor intervention to increase mammography screening. In this randomized, single blind study, participants were 181 African American female health center patients of ages 41 to 75 years, at < or =250% of poverty level, with no breast cancer history, and with no screening mammogram in the past 15 months. They were assigned to either (a) a low-dose comparison group consisting of a culturally appropriate mammography screening pamphlet or (b) interactive, tailored computer instruction at baseline and four monthly lay health advisor counseling sessions. Self-reported screening data were collected at baseline and 6 months and verified by medical record. For intent-to-treat analysis of primary outcome (medical record-verified mammography screening, available on all but two participants), the intervention group had increased screening to 51% (45 of 89) compared with 18% (16 of 90) for the comparison group at 6 months. When adjusted for employment status, disability, first-degree relatives with breast cancer, health insurance, and previous breast biopsies, the intervention group was three times more likely (adjusted relative risk, 2.7; 95% confidence interval, 1.8-3.7; P < 0.0001) to get screened than the low-dose comparison group. Similar results were found for self-reported mammography stage of screening adoption. The combined intervention was efficacious in improving mammography screening in low-income African American women, with an unadjusted effect size (relative risk, 2.84) significantly higher (P < 0.05) than that in previous studies of each intervention alone.

  9. National Water Quality Laboratory Profile

    USGS Publications Warehouse

    Raese, Jon W.

    1994-01-01

    The National Water Quality Laboratory determines organic and inorganic constituents in samples of surface and ground water, river and lake sediment, aquatic plant and animal material, and precipitation collected throughout the United States and its territories by the U.S. Geological Survey. In water year 1994, the Laboratory produced more than 900,000 analytical results for about 65,000 samples. The Laboratory also coordinates an extensive network of contract laboratories for the determination of radiochemical and stable isotopes and work for the U.S. Department of Defense Environmental Contamination Hydrology Program. Heightened concerns about water quality and about the possible effects of toxic chemicals at trace and ultratrace levels have contributed to an increased demand for impartial, objective, and independent data.

  10. High Energy Resolution Hyperspectral X-Ray Imaging for Low-Dose Contrast-Enhanced Digital Mammography.

    PubMed

    Pani, Silvia; Saifuddin, Sarene C; Ferreira, Filipa I M; Henthorn, Nicholas; Seller, Paul; Sellin, Paul J; Stratmann, Philipp; Veale, Matthew C; Wilson, Matthew D; Cernik, Robert J

    2017-09-01

    Contrast-enhanced digital mammography (CEDM) is an alternative to conventional X-ray mammography for imaging dense breasts. However, conventional approaches to CEDM require a double exposure of the patient, implying higher dose, and risk of incorrect image registration due to motion artifacts. A novel approach is presented, based on hyperspectral imaging, where a detector combining positional and high-resolution spectral information (in this case based on Cadmium Telluride) is used. This allows simultaneous acquisition of the two images required for CEDM. The approach was tested on a custom breast-equivalent phantom containing iodinated contrast agent (Niopam 150®). Two algorithms were used to obtain images of the contrast agent distribution: K-edge subtraction (KES), providing images of the distribution of the contrast agent with the background structures removed, and a dual-energy (DE) algorithm, providing an iodine-equivalent image and a water-equivalent image. The high energy resolution of the detector allowed the selection of two close-by energies, maximising the signal in KES images, and enhancing the visibility of details with the low surface concentration of contrast agent. DE performed consistently better than KES in terms of contrast-to-noise ratio of the details; moreover, it allowed a correct reconstruction of the surface concentration of the contrast agent in the iodine image. Comparison with CEDM with a conventional detector proved the superior performance of hyperspectral CEDM in terms of the image quality/dose tradeoff.

  11. Overview of the new National Near-Road Air Quality Monitoring Network

    EPA Science Inventory

    In 2010, EPA promulgated new National Ambient Air Quality Standards (NAAQS) for nitrogen dioxide (NO2). As part of this new NAAQS, EPA required the establishment of a national near-road air quality monitoring network. This network will consist of one NO2 near-road monitoring st...

  12. The Impact of Medicaid Coverage and Reimbursement on Access to Diagnostic Mammography

    PubMed Central

    Schuur, Jeremiah D.; Shah, Akash; Wu, Zheyang; Forman, Howard P.; Gross, Cary P.

    2013-01-01

    BACKGROUND Women of low socioeconomic status are at risk for delayed evaluation of abnormal mammograms and later stage presentations of breast cancer. Medicaid reimbursement for clinical services is lower than Medicare reimbursement, yet it is unclear whether low Medicaid reimbursement is a barrier to accessing mammography. The objective of the current study was to determine the association between reported insurance type (Medicaid vs Medicare), Medicaid reimbursement rate, and access to diagnostic mammography (DM). METHODS Standardized patients (SPs) called 521 mammography facilities in defined geographic regions of 11 states in 2005. Facilities were divided between high, middle, and low reimbursing states based on the state’s relative Medicaid-to-Medicare reimbursement rate for DM. SPs contacted each facility twice to schedule a DM using the same clinical vignette but switching insurance status (Medicaid vs Medicare). The authors measured the proportion of SPs who were offered 1) any appointment and 2) a timely appointment, defined as a third available appointment within 20 business days. RESULTS SPs with Medicaid were less likely to receive an appointment than SPs with Medicare (91% vs 99.1%; difference, 8.1%; 95% confidence interval, 5.3%–10.9% [P < .001]). Among facilities that offered appointments to both callers, the proportion of timely appointments did not differ between Medicaid (93.7%) and Medicare (92.9%; P = .51). States’ Medicaid reimbursement rates for DM were not associated with the percentage of SPs with Medicaid who were offered any appointment (P = .50) or a timely appointment (P = .69). CONCLUSIONS Callers with Medicaid were offered appointments for DM less frequently than callers with Medicare, although both were widely accepted. State Medicaid reimbursement rates did not affect access to mammography. PMID:19728371

  13. Post-Processing of Low Dose Mammography Images

    DTIC Science & Technology

    2002-05-01

    method of restoring images in the presence of blur as well as noise ” (12:276). The deblurring and denoising characteristics make Wiener filtering...independent noise . The signal dependant scatter noise can be modeled as blur in the mammography image. A Wiener filter with deblurring characteristics can...centered on. This method is used to eradicate noise impulses with high 26 pixel values (2:7). For the research at hand, the median filter would

  14. Development of silica-encapsulated silver nanoparticles as contrast agents intended for dual-energy mammography.

    PubMed

    Karunamuni, Roshan; Naha, Pratap C; Lau, Kristen C; Al-Zaki, Ajlan; Popov, Anatoliy V; Delikatny, Edward J; Tsourkas, Andrew; Cormode, David P; Maidment, Andrew D A

    2016-09-01

    Dual-energy (DE) mammography has recently entered the clinic. Previous theoretical and phantom studies demonstrated that silver provides greater contrast than iodine for this technique. Our objective was to characterize and evaluate in vivo a prototype silver contrast agent ultimately intended for DE mammography. The prototype silver contrast agent was synthesized using a three-step process: synthesis of a silver core, silica encapsulation and PEG coating. The nanoparticles were then injected into mice to determine their accumulation in various organs, blood half-life and dual-energy contrast. All animal procedures were approved by the institutional animal care and use committee. The final diameter of the nanoparticles was measured to be 102 (±9) nm. The particles were removed from the vascular circulation with a half-life of 15 min, and accumulated in macrophage-rich organs such as the liver, spleen and lymph nodes. Dual-energy subtraction techniques increased the signal difference-to-noise ratio of the particles by as much as a factor of 15.2 compared to the single-energy images. These nanoparticles produced no adverse effects in mice. Silver nanoparticles are an effective contrast agent for dual-energy x-ray imaging. With further design improvements, silver nanoparticles may prove valuable in breast cancer screening and diagnosis. • Silver has potential as a contrast agent for DE mammography. • Silica-coated silver nanoparticles are biocompatible and suited for in vivo use. • Silver nanoparticles produce strong contrast in vivo using DE mammography imaging systems.

  15. The development of efficient X-ray conversion material for digital mammography

    NASA Astrophysics Data System (ADS)

    Oh, K.; Shin, J.; Kim, S.; Lee, Y.; Jeon, S.; Kim, J.; Nam, S.

    2012-02-01

    In this study, an experimental method based on theory is used to develop photoconductor that can replace the a-Se currently used as X-ray conversion layer in digital mammography. This is necessary because a-Se produced by the commercial fabrication method, of physical vapor deposition, has exhibited several problems when applied to digital mammography: instability due to crystallization and defect expansion due to high operating voltages, which is called the aging effect. Therefore, our work focused on developing a method of fabricating X-ray conversion films that do not suffer from crystallization and X-ray damage and optimizing the factors affecting the properties of the candidate photoconductors in order to acquire sufficient electrical signals to detect minute calcifications. The photoconductors were initially selected after the requirements for X-ray conversion materials, such as high atomic absorption, density, band-gap energy, work function, and resistivity, were examined. We selected HgI2, PbI2, and PbO because of their basic properties. Next, we experimentally investigated the performance of film samples fabricated by sedimentation and screen printing instead of physical vapor deposition. The structure of the X-ray conversion films (e.g., the thickness, electrodes, and blocking layer) were optimized for the application of a relatively low voltage to the X-ray conversion layer. The performance of the films were morphologically and electrically evaluated under mammography X-ray exposure conditions, and compared with those of a-Se films produced by physical vapor deposition. PbO appeared to be the most suitable alternative material because its electrical properties, such as the dark current, sensitivity, and signal-to-noise ratio (SNR), did not reveal the X-ray damage problem, and thus were maintained after repeated exposure to X-rays. Although PbO showed low sensitivity to X-ray exposure, its SNR was superior to that of the other materials, which is expected

  16. National Water Quality Inventory, 1975 Report to Congress.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This document summarizes state submissions and provides a national overview of water quality as requested in Section 305(b) of the 1972 Federal Water Pollution Control Act Amendments (P.L. 92-500). This report provides the first opportunity for states to summarize their water quality and to report to EPA and Congress. Chapters of this report deal…

  17. A summary of the U.S. Geological Survey National Water-Quality Assessment program

    USGS Publications Warehouse

    Hirsch, R.M.; Alley, W.M.; Wilber, W.G.

    1988-01-01

    Beginning in 1986, the Congress appropriated funds for the U.S. Geological Survey to test and refine concepts for a National Water Quality Assessment Program. At present, the program is in a pilot phase with field studies occurring in seven areas around the Nation. In 1990, a committee of the National Academy of Sciences will complete an evaluation of the design and potential utility of the program. A decision about moving to full-scale implementation will be made upon completion of this evaluation. The program is intended to address a wide range of national water quality issues that include chemical contamination, acidification, eutrophication, salinity, sedimentation, and sanitary quality. The goals of the program are to: (1) provide nationally consistent descriptions of current water quality conditions for a large part of the Nation 's water resources; (2) define long-term trends (or lack of trends) in water quality; and (3) identify and describe the relations of both current conditions and trends in water quality to natural and human factors. This information will be provided to water managers, policy makers, and the public to provide an improved scientific basis for evaluating the effectiveness of water quality management programs and for predicting the likely effects of contemplated changes in land- and water-management practices. (USGS)

  18. Mammography Screening Trends: The Perspective of African American Women Born Pre/Post World War II

    PubMed Central

    Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A.

    2013-01-01

    Researchers have traditionally combined aging women (aged ≥50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non–baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non–baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947–0.968) cohort effects may have partially reversed the age effect, with non–baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278–2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population. PMID:20575209

  19. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    PubMed

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  20. Assessing tumor extent on contrast-enhanced spectral mammography versus full-field digital mammography and ultrasound.

    PubMed

    Patel, Bhavika K; Garza, Sandra Alheli; Eversman, Sarah; Lopez-Alvarez, Yania; Kosiorek, Heidi; Pockaj, Barbara A

    To compare breast cancer size measurements on full-field digital mammography (FFDM), contrast-enhanced spectral mammography (CEDM), and ultrasound (US), with histologic tumor size used as the reference standard. Material and methods The HIPAA complaint, IRB approved study comprised 88 women with newly diagnosed breast cancer who underwent FFDM and CEDM;74 also had US. Breast density, histologic subtype, and maximum tumor measurements were recorded. Pearson correlation coefficients for FFDM, US, and CEDM vs histopathology were 0.598, 0.639, and 0.859, respectively (P<0.001). The following correlation coefficients were calculated for dense breasts (n=48): histopathology vs FFDM (0.555), US (0.633), and CEDM (0.843) (P<0.001); for nondense breasts (n=40), they were FFDM (0.618), US (0.512), and CEDM (0.885) (P<0.001). For size difference, the mean (SD) for histopathology vs FFDM, US, and CEDM was -1.3 (11.9) mm, -2.8 (11.1) mm, and 2.9 (9.5) mm, respectively. Limits of agreement were -24.8 to 22.0mm, -24.5 to 18.8mm, and -15.6 to 21.4mm, respectively. In patients with biopsy-proven malignancy, size measurements correlated well with histopathologic size, and were higher on CEDM than those for FFDM and US in patients with dense or nondense breasts. The added value of CEDM as a supplement to FFDM in determining tumor size, however, was greater in patients with dense breasts. CEDM may be a promising alternative preoperative measurement tool for breast cancer patients with dense breasts and/or limited access or contraindications to MRI. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. The personal costs and convenience of screening mammography.

    PubMed

    Suter, Lisa Gale; Nakano, Connie Y; Elmore, Joann G

    2002-09-01

    Few studies have examined the impact of women's personal costs on obtaining a screening mammogram in the United States. All women obtaining screening mammograms at nine Connecticut mammography facilities during a 2-week study period were asked to complete a questionnaire. Facilities included urban and rural fixed sites and mobile sites. The survey included questions about insurance coverage, mammogram payment, and personal costs in terms of transportation, family care, parking, and lost work time from the women's perspective. The response rate was 62% (731 of 1189). Thirty-two percent of respondents incurred some type of personal cost, including lost work time, family care, and parking. Women incurring personal costs were more likely than those without personal costs to attend an urban facility (46% vs. 23%, p < 0.01) and be under the age of 50 (40% vs. 26%, p < 0.01). Overall, 61% of women listed convenience and 17% listed cost as a reason for choosing a mammography facility; 23% reported that cost might prevent them from obtaining a future mammogram. One third of women obtaining mammograms may be incurring personal costs. These personal costs should be considered in future cost-effectiveness analyses.

  2. Microbiological monitoring for the US Geological Survey National Water-Quality Assessment Program

    USGS Publications Warehouse

    Francy, Donna S.; Myers, Donna N.; Helsel, Dennis R.

    2000-01-01

    Data to characterize the microbiological quality of the Nation?s fresh, marine, and estuarine waters are usually collected for local purposes, most often to judge compliance with standards for protection of public health in swimmable or drinkable waters. Methods and procedures vary with the objectives and practices of the parties collecting data and are continuously being developed or modified. Therefore, it is difficult to provide a nationally consistent picture of the microbial quality of the Nation?s waters. Study objectives and guidelines for a national microbiological monitoring program are outlined in this report, using the framework of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) program. A national program is designed to provide long-term data on the presence of microbiological pathogens and indicators in ground water and surface water to support effective water policy and management. Three major groups of waterborne pathogens affect the public health acceptability of waters in the United States?bacteria, protozoa, and viruses. Microbiological monitoring in NAWQA would be designed to assess the occurrence, distribution, and trends of pathogenic organisms and indicators in surface waters and ground waters; relate the patterns discerned to factors that help explain them; and improve our understanding of the processes that control microbiological water quality.

  3. Socio-demographic correlates of participation in mammography: a survey among women aged between 35- 69 in Tehran, Iran.

    PubMed

    Samah, Asnarulkhadi Abu; Ahmadian, Maryam

    2012-01-01

    The rates of breast cancer have increased over the past two decades, and this raises concern about physical, psychological and social well-being of women with breast cancer. Further, few women really want to do breast cancer screening. We here investigated the socio-demographic correlates of mammography participation among 400 asymptomatic Iranian women aged between 35 and 69. A cross-sectional survey was conducted at the four outpatient clinics of general hospitals in Tehran during the period from July through October, 2009. Bi-variate analyses and multi-variate binary logistic regression were employed to find the socio- demographic predictors of mammography utilization among participants. The rate of mammography participation was 21.5% and relatively high because of access to general hospital services. More women who had undergone mammography were graduates from university or college, had full-time or part-time employment, were insured whether public or private, reported a positive family history of breast cancer, and were in the middle income level (P <0.01).The largest number of participating women was in the age range of 41 to 50 years. The results of multivariate logistic regression further showed that education (95%CI: 0.131-0.622), monthly income (95%CI: 0.038-0.945), and family history of breast cancer (95%CI: 1.97-9.28) were significantly associated (all P <0.05)with mammography participation. The most important issue for a successful screening program is participation. Using a random sample, this study found that the potential predictor variables of mammography participation included a higher education level, a middle income level, and a positive family history of breast cancer for Iranian women after adjusting for all other demographic variables in the model.

  4. Demographic factors influencing consensus opinion on the recall for women screened by mobile mammography unit in taiwan.

    PubMed

    Yu-Mei, Lee; Hsueh-Hua, Yao

    2013-09-01

    The incidence of breast cancer has had a four-fold increase from 1980 to 2005 in Taiwan. Limited data have been available on mobile breast screening in the Taiwanese population since 2009. This study aims at investigating the factors influencing consensus opinion on the recall for mobile breast screening in Taiwan. The factors were categorized by individual health background, socioeconomic status and knowledge about breast screening. There were 502 questionnaires collected from Taiwanese women examined on mobile mammography screening vehicle. Data were then analyzed by SPSS 12 via analysis of variance (ANOVA), F-test, t-test or chi-square test. Strong participation was associated with a younger age, higher educational level, higher incomes, previous history of cancer, previous family history of cancer, one or two prior mammographies, more correct recognitions of mammography, recall rate, and breast cancer risk. If the false-positive result occurred, 83.9%, 81.9% and 77.3% of the women agreed or strongly agreed to participate in noninvasive and invasive testing and screening mammography, respectively. The policy makers should notify the importance of demographic factors affecting further examination for early detection of breast cancer in Taiwan.

  5. [Analysis of Cost-effectiveness of screening for breast cancer with conventional mammography, digital and magnetic resonance imaging].

    PubMed

    Peregrino, Antonio Augusto de Freitas; Vianna, Cid Manso de Mello; de Almeida, Carlos Eduardo Veloso; Gonzáles, Gabriela Bittencourt; Machado, Samara Cristina Ferreira; Costa e Silva, Frances Valéria; Rodrigues, Marcus Paulo da Silva

    2012-01-01

    A cost-effectiveness analysis was conducted in screening for breast cancer. The use of conventional mammography, digital and magnetic resonance imaging were compared with natural disease history as a baseline. A Markov model projected breast cancer in a group of 100,000 women for a 30 year period, with screening every two years. Four distinct scenarios were modeled: (1) the natural history of breast cancer, as a baseline, (2) conventional film mammography, (3) digital mammography and (4) magnetic resonance imaging. The costs of the scenarios modeled ranged from R$ 194.216,68 for natural history, to R$ 48.614.338,31, for screening with magnetic resonance imaging. The difference in effectiveness between the interventions ranged from 300 to 78.000 years of life gained in the cohort. The ratio of incremental cost-effectiveness in terms of cost per life-year gains, conventional mammographic screening has produced an extra year for R$ 13.573,07. The ICER of magnetic resonance imaging was R$ 2.904.328,88, compared to no screening. In conclusion, it is more cost-effective to perform the screening with conventional mammography than other technological interventions.

  6. Design and development of a fiber optic TDI CCD-based slot-scan digital mammography system

    NASA Astrophysics Data System (ADS)

    Toker, Emre; Piccaro, Michele F.

    1993-12-01

    We previously reported on the development, design, and clinical evaluation of a CCD-based, high performance, filmless imaging system for stereotactic needle biopsy procedures in mammography. The MammoVision system has a limited imaging area of 50 mm X 50 mm, since it is designed specifically for breast biopsy applications. We are currently developing a new filmless imaging system designed to cover the 18 cm X 24 cm imaging area required for screening and diagnostic mammography. The diagnostic mammography system is based on four 1100 X 330 pixel format, full-frame, scientific grade, front illuminated, MPP mode CCDs, with 24 micrometers X 24 micrometers square pixels Each CCD is coupled to an x-ray intensifying screen via a 1.7:1 fiber optic reducer. The detector assembly (180 mm long and 13.5 mm wide) is scanned across the patient's breast synchronously with the x-ray source, with the CCDs operated in time-delay integration (TDI) mode. The total scan time is 4.0 seconds.

  7. [New mammography technologies and their impact on radiation dose].

    PubMed

    Chevalier del Rio, M

    2013-12-01

    This article reviews new mammography technologies resulting from advances in digital detectors and processing techniques. Most are just starting to be commercialized or are in the clinical trial phase. The results of clinical trials with the new 2D techniques (contrast-enhanced techniques or stereotactic techniques) show they are useful for diagnosing cancer. However, the greater complexity of the image acquisition process suggests that their use will be limited to particular cases such as inconclusive lesions or women with high risk for developing breast cancer. Among the 3D technologies (breast tomography and breast tomosynthesis), only breast tomosynthesis has been implemented in clinical practice, so it is the only technique for which it is possible to know the sensitivity, specificity, and radiation dose delivered. This article describes the principles underlying the way breast tomosynthesis works and the techniques used for image acquisition and reconstruction. It also summarizes the main results obtained in clinical studies, which generally show that breast tomosynthesis increases the breast cancer detection rate while decreasing the recall rate and number of biopsies taken. The protocol for breast tomosynthesis approved by the Food and Drug Administration (USA) consists of two conventional mammography projections for each breast and two tomosynthesis projections for each breast. This means multiplying the risks of inducing cancer and death associated with 2D mammography by a factor between 2 and 3 (2.6-3.3 and 0.7-0.9 per 100,000 women exposed when 50 years old, respectively). The protocol for breast tomosynthesis examinations is one of the aspects that is essential to determine when including tomosynthesis in screening programs and routine breast imaging. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  8. The use of ultrasonography and digital mammography in women under 40 years with symptomatic breast cancer: a 7-year Irish experience.

    PubMed

    Redmond, C E; Healy, G M; Murphy, C F; O'Doherty, A; Foster, A

    2017-02-01

    Breast cancer in women under 40 years of age is rare and typically presents symptomatically. The optimal imaging modality for this patient group is controversial. Most women undergo ultrasonography with/without mammography. Young women typically have dense breasts, which can obscure the features of malignancy on film mammography, however, initial studies have suggested that digital mammography may have a more accurate diagnostic performance in younger women. Ultrasound generally performs well in this age group, although it is poor at detecting carcinoma in situ (DCIS). To evaluate the comparative diagnostic performance of ultrasonography and digital mammography in the initial diagnostic evaluation of women under 40 years of age with symptomatic breast cancer. Retrospective review of all women under the age of 40 years managed at our symptomatic breast cancer unit from January 2009 to December 2015. There were 120 patients that met the inclusion criteria for this study. The sensitivity of ultrasonography and digital mammography for breast cancer in this patient group was 95.8 and 87.5 %, respectively. The patients with a false negative mammographic examination were more likely to have dense breasts (p < 0.01). Five patients had a false negative ultrasonographic examination, withal of whom were diagnosed with DCIS detected by mammography. This study demonstrates the superior sensitivity of ultrasound for breast cancer in women under the age of 40 years, however, the results show that digital mammography has an important complimentary role in the comprehensive assessment of these patients, particularly in the diagnosis of DCIS.

  9. Distributional benefit analysis of a national air quality rule.

    PubMed

    Post, Ellen S; Belova, Anna; Huang, Jin

    2011-06-01

    Under Executive Order 12898, the U.S. Environmental Protection Agency (EPA) must perform environmental justice (EJ) reviews of its rules and regulations. EJ analyses address the hypothesis that environmental disamenities are experienced disproportionately by poor and/or minority subgroups. Such analyses typically use communities as the unit of analysis. While community-based approaches make sense when considering where polluting sources locate, they are less appropriate for national air quality rules affecting many sources and pollutants that can travel thousands of miles. We compare exposures and health risks of EJ-identified individuals rather than communities to analyze EPA's Heavy Duty Diesel (HDD) rule as an example national air quality rule. Air pollutant exposures are estimated within grid cells by air quality models; all individuals in the same grid cell are assigned the same exposure. Using an inequality index, we find that inequality within racial/ethnic subgroups far outweighs inequality between them. We find, moreover, that the HDD rule leaves between-subgroup inequality essentially unchanged. Changes in health risks depend also on subgroups' baseline incidence rates, which differ across subgroups. Thus, health risk reductions may not follow the same pattern as reductions in exposure. These results are likely representative of other national air quality rules as well.

  10. Establishing daily quality control (QC) in screen-film mammography using leeds tor (max) phantom at the breast imaging unit of USTH-Benavides Cancer Institute

    NASA Astrophysics Data System (ADS)

    Acaba, K. J. C.; Cinco, L. D.; Melchor, J. N.

    2016-03-01

    Daily QC tests performed on screen film mammography (SFM) equipment are essential to ensure that both SFM unit and film processor are working in a consistent manner. The Breast Imaging Unit of USTH-Benavides Cancer Institute has been conducting QC following the test protocols in the IAEA Human Health Series No.2 manual. However, the availability of Leeds breast phantom (CRP E13039) in the facility made the task easier. Instead of carrying out separate tests on AEC constancy and light sensitometry, only one exposure of the phantom is done to accomplish the two tests. It was observed that measurements made on mAs output and optical densities (ODs) using the Leeds TOR (MAX) phantom are comparable with that obtained from the usual conduct of tests, taking into account the attenuation characteristic of the phantom. Image quality parameters such as low contrast and high contrast details were also evaluated from the phantom image. The authors recognize the usefulness of the phantom in determining technical factors that will help improve detection of smallest pathological details on breast images. The phantom is also convenient for daily QC monitoring and economical since less number of films is expended.

  11. Physical evaluation of a needle photostimulable phosphor based CR mammography system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Nicholas W.; Lemmens, Kim; Bosmans, Hilde

    2012-02-15

    Purpose: Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. Methods: Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose,more » for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. Results: MTF at 5 mm{sup -1} was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement ({approx}20%) over the two powder CR systems but remained 50% lower than the result at 5 mm{sup -1} for the a-Se detector ({approx}0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at {approx}100 {mu}Gy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm{sup -1}) was 0.19 for the needle CR plates, a factor

  12. Using automated texture features to determine the probability for masking of a tumor on mammography, but not ultrasound.

    PubMed

    Häberle, Lothar; Hack, Carolin C; Heusinger, Katharina; Wagner, Florian; Jud, Sebastian M; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger; Wittenberg, Thomas; Fasching, Peter A

    2017-08-30

    Tumors in radiologically dense breast were overlooked on mammograms more often than tumors in low-density breasts. A fast reproducible and automated method of assessing percentage mammographic density (PMD) would be desirable to support decisions whether ultrasonography should be provided for women in addition to mammography in diagnostic mammography units. PMD assessment has still not been included in clinical routine work, as there are issues of interobserver variability and the procedure is quite time consuming. This study investigated whether fully automatically generated texture features of mammograms can replace time-consuming semi-automatic PMD assessment to predict a patient's risk of having an invasive breast tumor that is visible on ultrasound but masked on mammography (mammography failure). This observational study included 1334 women with invasive breast cancer treated at a hospital-based diagnostic mammography unit. Ultrasound was available for the entire cohort as part of routine diagnosis. Computer-based threshold PMD assessments ("observed PMD") were carried out and 363 texture features were obtained from each mammogram. Several variable selection and regression techniques (univariate selection, lasso, boosting, random forest) were applied to predict PMD from the texture features. The predicted PMD values were each used as new predictor for masking in logistic regression models together with clinical predictors. These four logistic regression models with predicted PMD were compared among themselves and with a logistic regression model with observed PMD. The most accurate masking prediction was determined by cross-validation. About 120 of the 363 texture features were selected for predicting PMD. Density predictions with boosting were the best substitute for observed PMD to predict masking. Overall, the corresponding logistic regression model performed better (cross-validated AUC, 0.747) than one without mammographic density (0.734), but less well

  13. Non-attendance in mammography screening and women's social network: a cohort study on the influence of family composition, social support, attitudes and cancer in close relations.

    PubMed

    Manjer, Åsa Ritenius; Emilsson, Ulla Melin; Zackrisson, Sophia

    2015-06-28

    Mammography screening can reduce breast cancer mortality. The aim of the present study was to investigate non-attendance in mammography screening in relation to different aspects of a women's social network, attitudes and cancer in close relations. Data from the Malmö Diet and Cancer Study baseline examination in 1991-1996 was used. A re-examination began in 2007, and 1452 women participated. Family composition, social support, sense of belonging, attitudes on screening and breast cancer risk and on previous cancer in close relations were investigated in relation to self-reported participation in mammography screening using logistic regression analysis, yielding odds ratios with 95 % confidence intervals. Both attendees (98.0 %) and non-attendees (95.2 %) considered mammography screening important. Non-attendance in mammography screening was associated with being unmarried vs. married (2.40:1.30-4.45) and with not having vs. having children (1.77:1.08-2.92). Non-attendees planned to abstain from mammography screening in the future more often than attendees (4.78:2.56-8.90), and they had often abstained from cervical cancer screening (1.69:1.04-2.75). No other statistically significant association was found. This study indicates that family composition, but not necessarily the presence or absence of social support, perceived cancer risk or cancer in close relations, may affect non-attendance in mammography screening. A positive attitude towards mammography screening was found among both attendees and non-attendees, although the latter group planned to a lesser degree to attend mammography screening in the future.

  14. Optimization of x-ray capillary optics for mammography

    NASA Astrophysics Data System (ADS)

    Ross, Richard E.; Bradford, Carla D.; Peppler, Walter W.

    2002-05-01

    The purpose of this study is to develop a full-field digital mammography system utilizing capillary optics. Specific aims are to identify optic properties that affect image quality and to optimize those properties in the design of a multi-element capillary array. It has been shown that polycapillary optics significantly improve mammographic image quality through increased resolution and reduced x-ray scatter. For practical clinical application much larger multi-element optics will be required. This study quantified the contributing factors to the multi-element optic MTF and investigated methods to determine optimal parameters for a practical design. Individual and a prototype multi-element array of linearly tapered optics with a common focal point were investigated. A conventional (MO/MO) mammography tube and computed radiography system were used. The system and optic MTF were measured using the angled slit method with a slit camera (10 micron slit). MTF measurements were performed with both stationary and scanned optics. Contributions to MTF included: distortion within individual optics, misalignment between optics, capillary channel size, and vibration. Measurement techniques used to identify and quantify the contributions to optic MTF included a phantom chosen specifically for polycapillary optics. This phantom provided a method for assessing the coherence among capillaries within an optic as well as the relative alignment of the optics within the array. In addition, modifications to the scanning procedure allowed for the isolation and quantification of several contributors to the system MTF. Specifically, measurements were made using a stationary optic, a scanning optic, and an optic placed at multiple locations within the imaged field of view. These techniques yielded the optic MTF, the degradation of MTF due to loss of coherence within the optic, and the degradation of MTF due to vibration of the scanning mechanism. Distortion within individual optics was

  15. DEVELOPING A QUALITY SYSTEM FOR THE NATIONAL CHILDREN'S STUDY

    EPA Science Inventory

    A Quality Management Plan (QMP) is under development for a national, interagency, long-term study known as the National Children's Study (NCS). The NCS is a study to examine the effects of environmental influences on the health and development of more than 100,000 children acros...

  16. 77 FR 30280 - Final National Recommended Ambient Water Quality Criteria for Carbaryl-2012

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-22

    ... national recommended water quality criteria for the protection of aquatic life from effects of carbaryl... developed the aquatic life criteria based on EPA's Guidelines for Deriving Numerical National Water Quality... quality standards for protecting aquatic life and human health. These criteria are intended to protect...

  17. Receipt of mammography among women with intellectual disabilities: medical record data indicate substantial disparities for African American women.

    PubMed

    Parish, Susan L; Swaine, Jamie G; Son, Esther; Luken, Karen

    2013-01-01

    Little information exists on the receipt of mammography by African American women with intellectual disabilities. Given the high rates of mortality from breast cancer among African American women and low screening rates among women with intellectual disabilities, it is important to understand the health screening behavior of this population. We compared rates of mammography receipt among African American and White women with intellectual disabilities (n = 92) living in community settings in one Southeastern state in the United States. Data were collected from women's medical records or abstraction forms obtained from medical practices. Multivariate logistic regressions were modeled for receipt of mammography in one year, one of two years, or both study years (2008- 2009). Covariates included the women's age, living arrangement, severity of impairment, and urban/rural residence location. In 2009, 29% of African American women and 59% of White women in the sample received mammograms. Similar disparities were found for receipt of mammography in either 2008 or 2009 and both 2008 and 2009. These disparities persisted after inclusion of model covariates. White women with intellectual disabilities received mammograms at adjusted rates that were nearly three to five times higher than African American women. African American women with intellectual disabilities receive mammography at significantly lower rates than White women with intellectual disabilities. Assertive measures to improve the screening rates for African American women with intellectual disabilities are urgently needed. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Task-based strategy for optimized contrast enhanced breast imaging: analysis of six imaging techniques for mammography and tomosynthesis

    NASA Astrophysics Data System (ADS)

    Ikejimba, Lynda; Kiarashi, Nooshin; Lin, Yuan; Chen, Baiyu; Ghate, Sujata V.; Zerhouni, Moustafa; Samei, Ehsan; Lo, Joseph Y.

    2012-03-01

    Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique that provides 3D structural information of the breast. In contrast to 2D mammography, DBT minimizes tissue overlap potentially improving cancer detection and reducing number of unnecessary recalls. The addition of a contrast agent to DBT and mammography for lesion enhancement has the benefit of providing functional information of a lesion, as lesion contrast uptake and washout patterns may help differentiate between benign and malignant tumors. This study used a task-based method to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: contrast enhanced mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Imaging performance was characterized using a detectability index d', derived from the system task transfer function (TTF), an imaging task, iodine contrast, and the noise power spectrum (NPS). The task modeled a 5 mm lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d' was generated as a function of dose and iodine concentration. In general, higher dose gave higher d', but for the lowest iodine concentration and lowest dose, dual energy subtraction tomosynthesis and temporal subtraction tomosynthesis demonstrated the highest performance.

  19. Classification of breast microcalcifications using spectral mammography

    NASA Astrophysics Data System (ADS)

    Ghammraoui, B.; Glick, S. J.

    2017-03-01

    Purpose: To investigate the potential of spectral mammography to distinguish between type I calcifications, consisting of calcium oxalate dihydrate or weddellite compounds that are more often associated with benign lesions, and type II calcifications containing hydroxyapatite which are predominantly associated with malignant tumors. Methods: Using a ray tracing algorithm, we simulated the total number of x-ray photons recorded by the detector at one pixel from a single pencil-beam projection through a breast of 50/50 (adipose/glandular) tissues with inserted microcalcifications of different types and sizes. Material decomposition using two energy bins was then applied to characterize the simulated calcifications into hydroxyapatite and weddellite using maximumlikelihood estimation, taking into account the polychromatic source, the detector response function and the energy dependent attenuation. Results: Simulation tests were carried out for different doses and calcification sizes for multiple realizations. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to 0.99. Conclusion: Our simulation results obtained for a uniform breast imaging phantom indicate that spectral mammography using two energy bins has the potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications to improve early breast cancer diagnosis and reduce the number of unnecessary breast biopsies.

  20. Towards more effective online information support for mammography screening decisions.

    PubMed

    Martucci, Jessica; Schmidt, Harald

    2018-06-01

    We sought to determine the extent to which web-based patient-directed resources of U.S. public health agencies and professional groups offer consistent and relevant information on the benefits and harms of mammography screening. Between August 2016-February 2017, we identified, collected and analyzed information about mammography screening from the websites of 14 well-known governmental public health agencies and professional groups. We recorded and compared the qualitative and quantitative information the sites offered on (1) breast cancer mortality; (2) false-positive results; (3) unnecessary biopsy; and (4) overdetection. Our results show considerable variation on which benefits and harms are mentioned, whether they are discussed in qualitative and/or quantitative terms, and how this information is delivered and framed. We argue that it is ethically problematic that benefit and harm information is presented in inconsistent and incomplete ways, and we suggest that organizations work towards the adoption of uniform categories to genuinely support preference-sensitive decision making. Copyright © 2017 Elsevier Inc. All rights reserved.