Glove permeation by semiconductor processing mixtures containing glycol-ether derivatives.
Zellers, E T; Ke, H Q; Smigiel, D; Sulewski, R; Patrash, S J; Han, M W; Zhang, G Z
1992-02-01
Results of permeation tests of several glove materials challenged with semiconductor processing formulations containing glycolether derivatives are described. Commercial glove samples of nitrile rubber (Edmont), natural rubber (Edmont and Baxter), butyl rubber (North), PVC Baxter), a natural rubber/neoprene/nitrile blend (Pioneer), and a natural rubber/neoprene blend (Playtex) were tested according to the ASTM F739-85 permeation test method (open-loop configuration). The liquid formulations examined included a positive photoresist thinner containing 2-ethoxyethyl acetate (2-EEA), n-butyl acetate, and xylene; a positive photoresist containing 2-EEA, n-butyl acetate, xylene, polymer resins, and photoactive compounds; a negative photoresist containing 2-methoxyethanol (2-ME), xylene, and cyclized poly(isoprene); and pure 2-methoxyethyl acetate (2-MEA), which is the solvent used in a commercial electron-beam resist. With the exception of the negative photoresist, butyl rubber provided the highest level of protection against the solvent mixtures tested, with no breakthrough observed after 4 hr of continuous exposure at 25 degrees C. Nitrile rubber provided the highest level of protection against the negative photoresist and reasonably good protection against initial exposure to the other solvent mixtures. Gloves consisting of natural rubber or natural rubber blends provided less protection against the mixtures than either nitrile or butyl rubber. For most of the glove samples, permeation of the glycol-ether derivatives contained in the mixtures was faster than that predicted from the permeation of the pure solvents. Increasing the exposure temperature from 25 to 37 degrees C did not significantly affect the performance of the butyl rubber glove. For the other gloves, however, exposures at 37 degrees C resulted in decreases in breakthrough times of 25-75% and increases in steady-state permeation rates of 80-457% relative to values obtained at 25 degrees C. Repeated exposure of nitrile rubber samples resulted in shorter breakthrough times for all mixture components. In fact, exposure for as little as one-half of the nominal breakthrough time followed by air drying overnight resulted in measurable quantities of one or more of the component solvents at the inner surface of the gloves at the beginning of the next exposure. This effect was not observed with the butyl rubber samples. With the exception of the negative photoresist, heating previously exposed nitrile rubber samples at 70 degrees C for 20 hr prior to retesting reduced or eliminated the effects of residual solvents, permitting reuse of the gloves. The use of thin PVC or natural rubber gloves adjacent to the nitrile gloves provided moderate increases in permeation resistance.(ABSTRACT TRUNCATED AT 400 WORDS)
Fundamentals of the knowledge about chemical additives present in rubber gloves.
Oliveira, Hegles Rosa de; Alchorne, Alice de Oliveira de Avelar
2011-01-01
One of the most frequent causes of allergic contact dermatitis of occupational origin are rubber additives, which are present in Personal Protective Equipment (PPE). The most allergenic additives of natural and synthetic gloves are thiurams, carbamates and mercapto group. To investigate the state of knowledge about the chemical additives used in the manufacture of synthetic rubber gloves. This was a qualitative research study in which professionals working in the manufacture, research, prescription and commercialization of gloves answered an open questionnaire. 30 individuals were interviewed: 4 researchers in occupational medicine, 5 occupational physicians, 2 occupational safety technicians, a rubber workers' union physician, an occupational safety engineer, a pro duction engineer of rubber gloves, 4 importers of gloves, a manufacturer of gloves, 3 businessmen who sell PPE, 3 salesclerks working in stores that sell PPE, 2 businessmen who own stores that sell products for allergic individuals, and 3 dermatologists. Knowledge of the chemical composition of rubber gloves is scant. The labeling of gloves, with the description of their chemical composition, would facilitate choosing the best type of glove for each person. This low-cost action to businesses would be a gain from the standpoint of public health, with huge repercussions for users of rubber gloves.
Permeability of different types of medical protective gloves to acrylic monomers.
Lönnroth, Emma-Christin; Wellendorf, Hanne; Ruyter, Eystein
2003-10-01
Dental personnel and orthopedic surgeons are at risk when manually handling products containing methyl methacrylate (MMA). Dental products may also contain cross-linking agents such as ethylene glycol dimethacrylate (EGDMA) or 1,4-butanediol dimethacrylate (1,4-BDMA). Skin contact with monomers can cause hand eczema, and the protection given by gloves manufactured from different types of material is not well known. The aim of this study was to determine the breakthrough time (BTT, min) as a measure of protection (according to the EU standard EN-374-3) for a mixture consisting of MMA, EGDMA and 1,4-BDMA. Fifteen different gloves representing natural rubber latex material, synthetic rubber material (e.g. nitrile rubbers), and synthetic polymer material were tested. The smallest monomer MMA permeated within 3 min through all glove materials. A polyethylene examination glove provided the longest protection period to EGDMA and 1, 4-BDMA (> 120 min and 25.0 min), followed by the surgical glove Tactylon (6.0 min and 8.7 min) and the nitrile glove Nitra Touch (5.0 min and 8.7 min). This study showed that the breakthrough time (based on permeation rate) cannot be regarded as a 'safe limit'. When the permeation rate is low, monomers may have permeated before BTT can be determined. Using double gloves with a synthetic rubber inner glove and a natural rubber outer glove provided longer protection when the inner glove was rinsed in water before placing the outer glove on top.
Nawong, Chairat; Umsakul, Kamontam; Sermwittayawong, Natthawan
2018-02-03
An increasing production of natural rubber (NR) products has led to major challenges in waste management. In this study, the degradation of rubber latex gloves in a mineral salt medium (MSM) using a bacterial consortium, a mixed culture of the selected bacteria and a pure culture were studied. The highest 18% weight loss of the rubber gloves were detected after incubated with the mixed culture. The increased viable cell counts over incubation time indicated that cells used rubber gloves as sole carbon source leading to the degradation of the polymer. The growth behavior of NR-degrading bacteria on the latex gloves surface was investigated using the scanning electron microscope (SEM). The occurrence of the aldehyde groups in the degradation products was observed by Fourier Transform Infrared Spectroscopy analysis. Rhodococcus pyridinivorans strain F5 gave the highest weight loss of rubber gloves among the isolated strain and posses latex clearing protein encoded by lcp gene. The mixed culture of the selected strains showed the potential in degrading rubber within 30 days and is considered to be used efficiently for rubber product degradation. This is the first report to demonstrate a strong ability to degrade rubber by Rhodococcus pyridinivorans. Copyright © 2018. Published by Elsevier Editora Ltda.
Mechanisms to improve the mechanical performance of surgical gloves
NASA Astrophysics Data System (ADS)
Watkins, Michelle Hoyt
1997-11-01
The use of gloves as a barrier to cross infection in the medical industry has increased substantially due to the heightened awareness of viral transmission, especially the human immunodeficiency virus and the hepatitis B virus. The glove must allow for tactile sensation, comfort and long use times, while providing equally critical mechanical performance. The majority of surgical gloves are made of natural rubber latex which do not give a critical level of cut-resistance or puncture-resistance. Natural rubber latex gloves are also known to cause latex allergy with hypersensitivity reactions ranging from mild skin rashes to more severe bronchial asthma, anaphylactic reactions, and even death. It has been postulated natural rubber latex (NRL) proteins cause these allergic reactions. The research that has been conducted comprises two approaches that have been explored for improving the cut-resistance of surgical gloves. The first method involves an integral fiber-latex structure that possesses the combination of high reversible extensibility, barrier performance and retention of tactile sense. Improvement in mechanical properties in excess of 85% has been achieved as well as an improvement in cut-resistance. The second method involves the incorporation of a low concentration of ultra high molecular weight (UHMW) polyacrylamide. Although the initial premise for using a UHMW polymer was that it would bridge the latex compound particulates to improve strength, an entirely different mechanism for the enhancement of strength was explored through a parallel investigation of the release of proteins from cured natural rubber. However, no mechanism was conclusively identified. To address the allergy aspects of NRL, a thorough examination of the release of naturally-occurring latex proteins from cured natural rubber latex glove material was conducted in order to identify mechanisms for eliminating and/or reducing the potential allergens. The initial study examined the release of loaded proteins from cured NR and NR that contained PA in the initial latex compound and the results showed the likelihood of binding between proteins and PA.
21 CFR 878.4460 - Surgeon's glove.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Identification. A surgeon's glove is a device made of natural or synthetic rubber intended to be worn by... used in the glove is excluded. (b) Classification. Class I (general controls). [53 FR 23872, June 24...
Setting standards for product selection: allergy prevention.
White, I R
1997-01-01
It is axiomatic to state that if products made of natural rubber latex were not used in health care settings then there would be no problems of acquired hypersensitivity from such products. Although synthetic materials are available they do not currently possess the same technical qualities of elasticity and comfort, nor do they deliver the desired degree of protection against biological agents as gloves made out of natural rubber latex. Selection of gloves either for non-sterile procedures or sterile surgical use should be based on this understanding, and gloves with minimal levels of extractable latex proteins should be used.
Hamilton, R G; Adkinson, N F
1996-11-01
Nonammoniated latex, ammoniated latex, and rubber glove extracts are the only sources of natural rubber (Hevea brasiliensis) latex that have potential for use as skin testing reagents in the diagnosis of latex allergy. Their diagnostic sensitivity and specificity as skin test reagents are unknown. We conducted a phase 1/2 clinical study to examine the safety and diagnostic accuracy (sensitivity and specificity) of nonammoniated latex, ammoniated latex, and rubber glove extracts as skin test extracts to identify the most efficacious source material for future skin test reagent development. Twenty-four adults not allergic to latex, 19 adults with hand dermatitis or pruritus, and 59 adults with a latex allergy were identified by clinical history. All provided blood and then received puncture skin tests and intradermal skin tests with nonammoniated latex, ammoniated latex, and rubber glove extracts from Malaysian H. brasiliensis latex by use of sequential titration. A glove provocation test and IgE anti-latex RAST were used to clarify positive history-negative skin test response and negative history-positive skin test response mismatches. All three extracts were biologically safe and sterile. After normalization to 1 mg/ml of total protein, all three extracts produced equivalent diagnostic sensitivity and specificity in puncture skin tests and intradermal skin tests at various extract concentrations. Optimal diagnostic accuracy was safely achieved at 100 micrograms/ml for intradermal skin tests (e.g., nonammoniated latex: puncture skin test sensitivity 96%, specificity 100%; intradermal skin test sensitivity 93%, specificity 96%). The presence of IgE antibody in skin was highly correlated with IgE anti-latex in serum (nonammoniated latex: r = 0.98, p < 0.001; ammoniated latex: r = 0.94, p < 0.001; rubber glove extract: r = 0.96, p < 0.001). All five available subjects with a positive history, negative skin test response, and absence of IgE antibody in serum had a negative glove provocation test response, indicating no clinical evidence of latex allergy. No systemic or large local allergic reactions were observed with puncture skin tests or intradermal skin tests. Equivalent diagnostic sensitivity and specificity were observed with the nonammoniated latex, ammoniated latex, and rubber glove extract skin test reagents after normalization for total protein; nonammoniated latex may be considered the reagent of choice on the basis of practical quality control and reproducibility considerations.
The manufacture of gloves from natural rubber latex.
Yip, Esah; Cacioli, Paul
2002-08-01
Gloves that will provide a barrier of protection from infectious organisms are an essential feature of medical practice for the protection of both patients and medical personnel. Natural rubber latex has consistently been the most satisfactory raw material for the manufacture of gloves. Certain latex proteins, carried over into the finished product by inadequate manufacturing processes, may pose a risk of provoking allergic reactions in some patients and medical workers. As with any allergy, the risk depends on the route of exposure and dose. Hence, the method of manufacture, including the means used to coat gloves to make donning easy, can influence the eventual exposure of sensitive people to latex allergens. In this article, we describe the several processes in use and their effects on latex protein content.
30 CFR 77.606-1 - Rubber gloves; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINES Trailing Cables § 77.606-1 Rubber gloves; minimum requirements. (a) Rubber gloves (lineman's gloves) worn while handling high-voltage trailing cables shall be rated at least 20,000 volts and shall... gloves (wireman's gloves) worn while handling trailing cables energized by 660 to 1,000 volts shall be...
The effect of filler on the protein content and interferences in rubber latices
NASA Astrophysics Data System (ADS)
Ruhida, A. R.; Hassan, Aziz
2017-12-01
It is well known that the application of commercial fillers like calcium carbonate has widely been used in natural rubber latex (NRL) gloves as well as other dipped products such as balloons, condom and catheters. The main reason of adding the fillers into the rubber compound was as cheapening aid and to improve the end-product properties. Due to its functional benefit, many studies have been conducted on the application and beneficial usage of fillers in natural rubber (NR) compounds and natural rubber latex (NRL) dipped goods namely gloves. However most of the studies were basically emphasizing on the effect of fillers on the physical properties and surface morphology of rubber. Not many studies have been conducted to investigate the effect of filler on the protein content in NRL products. Earlier work by other workers has only been concentrating on the effect of nano-sized calcium carbonate fillers in NR latex gloves. Because of the concern on the issue of latex protein allergy; it is thus important to study the effect of filler on protein content and its interferences in the rubber lattices. This paper will seek to elaborate on the effect of filler content on the total protein and extractable protein (EP) content of NR latex films at various filler loadings before and after ageing. The effect of interferences by filler that was mixed into the NR latex on the total nitrogen and EP content were also measured and shown.
The Use of Latex Gloves in the School Setting
ERIC Educational Resources Information Center
Purcell, Cathy Koeppen
2006-01-01
In 1987, when the U.S. Centers for Disease Control and Prevention recommended the use of universal precautions in response to the HIV/AIDS epidemic, the demand for medical gloves dramatically increased. Unfortunately, the manufacturing techniques for the most widely-used gloves--natural rubber latex--also changed, in order to expedite production.…
Contact Dermatitis from Penetration of Rubber Gloves by Acrylic Monomer
Pegum, J. S.; Medhurst, F. A.
1971-01-01
An orthopaedic surgeon developed dermatitis from acrylic materials. The acrylic monomer was found to penetrate surgical rubber gloves readily. Cases of “rubber glove dermatitis” with negative patch tests may have a similar explanation. Laboratory tests suggest that monomer does not damage rubber sufficiently to allow bacteria to penetrate gloves, but it remains possible that this would happen under theatre conditions. PMID:5581492
Resistance of gloves and protective clothing materials to permeation of cytostatic solutions.
Krzemińska, Sylwia; Pośniak, Małgorzata; Szewczyńska, Małgorzata
2018-01-15
The objective of the work was to determine the resistance of selected protective clothing and glove materials to permeation of cytostatics such as docetaxel, fluorouracil, and doxorubicin. The following glove materials were used: natural rubber latex (code A), acrylonitrile-butadiene rubber (code B) and chloroprene rubber (code C). In addition, we tested a layered material composed of a non-woven polyester (PES), a polypropylene (PP) film, and a non-woven PP used for protective coats (code D). The cytostatics were analyzed by liquid chromatography with diode array detection. The tested samples were placed in a purpose-built permeation cell modified to be different from that specified in the standard EN 6529:2001. The tested materials were characterized by good resistance to solutions containing 2 out of the 3 selected cytostatics: doxorubicin and 5-fluorouracil, as indicated by a breakthrough time of over 480 min. Equally high resistance to permeation of the third cytostatic (docetaxel) was exhibited by natural rubber latex, acrylonitrile-butadiene rubber, and chloroprene rubber. However, docetaxel permeated much more readily through the clothing layered material, compromising its barrier properties. It was found that the presence of additional components in cytostatic preparations accelerated permeation through material samples, thus deteriorating their barrier properties. Int J Occup Med Environ Health 2018;31(3):341-350. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Gill, C O; Jones, T
2002-06-01
On eight occasions, five volunteers each handled five pieces of meat with bare hands or while wearing dry or wet knitted gloves or rubber gloves after hands had been inoculated with Escherichia coli or after handling a piece of meat inoculated with E. coli. On each occasion, after all meat was handled, each piece of meat, glove, and hand were sampled to recover E. coli. When hands were inoculated, E. coli was recovered from all meat handled with bare hands, in lesser numbers from some pieces handled with knitted gloves, and from only one piece handled with rubber gloves. When pieces of inoculated meat were handled, the numbers of E. coli transferred to uninoculated meat from bare hands or rubber gloves decreased substantially with each successive piece of uninoculated meat, but decreases were small with knitted gloves. The findings indicate that, compared with bare hands, the use of knitted gloves could reduce the transfer of bacteria from hands to meat but could increase the transfer of bacteria between meat pieces, whereas the use of rubber gloves could largely prevent the first and greatly reduce the second type of bacteria transfer.
Henriks-Eckerman, Maj-Len; Mäkelä, Erja
2015-03-01
Reported cases of allergic contact dermatitis caused by methylenediphenyl diisocyanate (MDI) have increased and thereby increased the need for adequate skin protection. Current standardized permeation and penetration test methods give information about efficacy of protective materials against individual components of the polyurethane systems. They do not give information of what kind of clothing materials workers should wear against splashes when handling mixed MDI-polyurethane formulations, which contain MDI, its oligomers, and polyols. The aim of this study was to develop and validate a sensitive penetration test method that can be used to select clothing that is protective enough against uncured splashes of MDI-polyurethane, still easy to use, and also, to find affordable glove materials that provide adequate protection during a short contact. The penetration of MDI through eight representative glove or clothing materials was studied with the developed test procedure. One MDI hardener and two polymeric MDI (PMDI)-polyol formulations representing different curing times were used as test substances. The materials tested included work clothing (woven) fabric, arm shields (nonwoven fabric), old T-shirt, winter gloves, and gloves of nitrile rubber, leather, vinyl (PVC), and natural rubber. A drop (50 µl) of test substance was added to the outer surface of the glove/clothing material, which had Tape Fixomull attached to the inner surface as a collection medium. After penetration times of 5 or 20min, the collecting material was removed and immediately immersed into acetonitrile containing 1-(2-methoxyphenyl)-piperazine for derivatization. The formed urea derivatives of 2,4'-MDI and 4,4'-MDI were analysed using liquid chromatography with mass spectrometric and UV detection. The precision of the test method was good for the material with high penetration (work clothing fabric) of MDI, as the relative standard deviation (RSD) was 14 and 20%. For the arm shield with a low penetration (the nonwoven fabric), the precision was lower with RSDs of 35 and 50%. For two clothing materials, the penetration was high (134-577 µg cm(-2)). Low penetration (<0.5 µg cm(-2)) was shown by the arm shield and the natural rubber glove. Three glove materials showed no detectable MDI penetration (<0.002 µg cm(-2)). Two affordable glove materials (natural rubber and nitrile rubber) and one clothing material (dust proof arm shield) that can provide adequate protection during short contact with solvent free PMDI formulations were found. The new test procedure should be standardized in order to get a new international penetration standard. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
[Migrants from disposable gloves and residual acrylonitrile].
Wakui, C; Kawamura, Y; Maitani, T
2001-10-01
Disposable gloves made from polyvinyl chloride with and without di(2-ethylhexyl) phthalate (PVC-DEHP, PVC-NP), polyethylene (PE), natural rubber (NR) and nitrile-butadiene rubber (NBR) were investigated with respect to evaporation residue, migrated metals, migrants and residual acrylonitrile. The evaporation residue found in n-heptane was 870-1,300 ppm from PVC-DEHP and PVC-NP, which was due to the plasticizers. Most of the PE gloves had low evaporation residue levels and migrants, except for the glove designated as antibacterial, which released copper and zinc into 4% acetic acid. For the NR and NBR gloves, the evaporation residue found in 4% acetic acid was 29-180 ppm. They also released over 10 ppm of calcium and 6 ppm of zinc into 4% acetic acid, and 1.68-8.37 ppm of zinc di-ethyldithiocarbamate and zinc di-n-butyldithiocarbamate used as vulcanization accelerators into n-heptane. The acrylonitrile content was 0.40-0.94 ppm in NBR gloves.
Mutsuga, M; Wakui, C; Kawamura, Y; Maitani, T
2002-11-01
In Japan, disposable gloves made from nitrile-butadiene rubber (NBR) are frequently used in contact with foods. In a previous paper, we investigated substances migrating from various gloves made of polyvinyl chloride, polyethylene, natural rubber and NBR. Zinc di-n-butyldithiocarbamate (ZDBC), diethyldithiocarbamate (ZDEC) used as vulcanization accelerators, di(2-ethylhexyl)phthalate (DEHP) used as a plasticizer and many unknown compounds that migrated from NBR gloves into n-heptane were detected by GC/MS. In this paper, six unknown compounds were obtained from one kind of NBR glove by n-hexane extraction and each was isolated by silica gel chromatography. From the results of NMR and mass spectral analysis of the six unknown compounds, their structures are proposed as 1,4-dione-2,5-bis(1,1-dimethylpropyl)cyclohexadiene (1), 2-(1,1-dimethylethyl)-4-(1,1,3,3-tetra methylbutyl)phenol (2), 2,6-bis(1,1-dimethylethyl)-4-(1,1,3,3-tetramethylbutyl)phenol (3), 2,4-bis(1,1,3,3-tetramethylbutyl)phenol (4), 2-(1,1-dimethylethyl)4,6-bis(1,1,3,3-tetramethylbutyl)phenol (5) and 2,4,6-tris(1,1,3,3-tetramethylbutyl)phenol (6). Compound 1 was observed in five of the seven kinds of NBR gloves, and compounds 2-4 and 6, which are not listed in Chemical Abstract (CA), were present in four kinds of gloves.
Natural rubber latex allergy after 12 years: recommendations and perspectives.
Charous, B Lauren; Blanco, Carlos; Tarlo, Susan; Hamilton, Robert G; Baur, Xaver; Beezhold, Donald; Sussman, Gordon; Yunginger, John W
2002-01-01
Natural rubber latex (NRL) allergy is a "new" illness whose prevalence reached epidemic proportions in highly exposed populations during the last decade. In children with spina bifida and in patients exposed to NRL during radiologic procedures, institution of prophylactic safety measures has had demonstrable effects in preventing allergic reactions. The risk of NRL allergy appears to be largely linked to occupational exposure, and NRL-associated occupational asthma is due almost solely to powdered latex glove use. Prevalence of NRL-allergic sensitization in the general population is quite low; several studies of young adults demonstrate rates of positive skin test results that are less than 1%. After occupational exposure, rates of sensitization and NRL-induced asthma rise dramatically in individuals using powdered NRL gloves but not in individuals using powder-free gloves. Airborne NRL is dependent on the use of powdered NRL gloves; conversion to non-NRL or nonpowdered NRL substitutes results in predictable rapid disappearance of detectable levels of aeroallergen. For these reasons, adoption of the following institutional policies designed to prevent new cases of NRL allergy and maximize safety is recommended: (1) NRL gloves should be used only as mandated by accepted Standard Precautions; (2) only nonpowdered, nonsterile NRL gloves should be used; and (3) nonpowdered, sterile NRL gloves are preferred for use. Low-protein powdered, sterile gloves may be used, but only in conjunction with an ongoing assessment for development of allergic reactions.
75 FR 68394 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... Woven and Knit impregnated with Flat Dipped Rubber/Plastic Gloves. SUMMARY: The U. S. Small Business... Flat Dipped Rubber/Plastic Gloves, under North American Industry Classification System (NAICS) code... Rule for Woven and Knit impregnated with Flat Dipped Rubber/Plastic Gloves under PSC 9999...
75 FR 52789 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... for Woven and Knit impregnated with Flat Dipped Rubber/Plastic Gloves. SUMMARY: The U.S. Small... for woven and knit impregnated with flat dipped rubber/plastic gloves, under the North American... Dipped Rubber/Plastic Gloves manufacturers. If granted, the waiver would allow otherwise qualified small...
Van Wicklin, Sharon A
2016-05-01
Variations in documenting surgical wound classification Key words: surgical wound classification, clean, clean-contaminated, contaminated, dirty. Wearing long-sleeved jackets while preparing and packaging items for sterilization Key words: long-sleeved jackets, organic material, sterile processing. Endoscopic transmission of prions Key words: prions, high-risk tissue, low-risk tissue, Creutzfeldt-Jakob disease (CJD), variant Creutzfeldt-Jakob disease (vCJD). Wearing gloves when handling flexible endoscopes Key words: gloves, low-protein, powder-free, natural rubber latex gloves, latex-free gloves. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Choosing the right surgical glove: an overview and update.
Tanner, Judith
Sterile surgical gloves are routinely worn during all invasive procedures to prevent the two-way transmission of pathogens between the surgical team and the patient. This reduces the risk of surgical-site infections and blood-borne diseases. Since their introduction to the operating room over 100 years ago, surgical gloves, and the materials used to make them, have continued to evolve in line with ever-changing healthcare demands. Following recent developments in surgical glove technologies, including de-proteinized natural rubber latex and newer gloving methods such as triple gloving, it is timely that an overview and update of surgical gloves is given. By providing information on latex-associated allergies, glove materials, gloving methods and glove protection, this article will enable practitioners to choose the most appropriate surgical glove.
EVALUATION OF GLOVEBOX GLOVES FOR EFFECTIVE PERMEATION CONTROL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P.
A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton{reg_sign}, Dupont{reg_sign} Hypalon{reg_sign}, polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton{reg_sign} gloves performed comparably in both gases.
Yoo, Won-Gyu
2015-01-01
[Purpose] The present study examined the effects of wearing rubber gloves on the activities of the forearm and shoulder muscles during two dishwashing stages. [Subjects] This study included 10 young females. [Methods] The participants performed two dishwashing stages (washing and rinsing) with and without rubber gloves. The activities of the wrist flexor and upper trapezius muscles were measured using wireless electromyography. [Results] During the washing stage, the activities of the wrist flexor and upper trapezius muscles were significantly greater without gloves than with gloves when performing the same tasks. However, during the rinsing stage, the activities of these muscles did not differ significantly according to the use of gloves. [Conclusion] Dishwashers should wear gloves during the washing stage to prevent wrist and shoulder pain. PMID:26311980
Outcomes of a natural rubber latex control program in an Ontario teaching hospital.
Tarlo, S M; Easty, A; Eubanks, K; Parsons, C R; Min, F; Juvet, S; Liss, G M
2001-10-01
Allergy to natural rubber latex (NRL) has been frequently reported in health care workers. However, there is little published evidence of the outcome of hospital intervention programs to reduce exposure and detect cases of sensitization early. This study assesses the effects of intervention to reduce NRL allergy in an Ontario teaching hospital with approximately 8000 employees. A retrospective review assessed annual numbers of employees visiting the occupational health clinic, allergy clinic, or both for manifestations of NRL allergy compared with the timing of introduction of intervention strategies, such as worker education, voluntary medical surveillance, and hospital conversion to low-protein, powder-free NRL gloves. The number of workers identified with NRL allergy rose annually, from 1 in 1988 to 6 in 1993. When worker education and voluntary medical surveillance were introduced in 1994, a further 25 workers were identified. Nonsterile gloves were changed to low-protein, powder-free NRL gloves in 1995: Diagnoses fell to 8 workers that year, and 2 of the 3 nurses who had been off work because of asthma-anaphylaxis were able to return to work with personal avoidance of NRL products. With a change to lower protein, powder-free NRL sterile gloves in 1997, allergy diagnoses fell to 3, and only 1 new case was identified subsequently up to May 1999. No increased glove costs were incurred as a result of consolidated glove purchases. This program to reduce NRL allergy in employees was effectively achieved without additional glove costs while reducing expenses from time off work and workers' compensation claims.
Perera, Ambegoda Liyanage Harini Amalka
2017-01-01
Natural rubber latex (NRL) allergy is caused by the extractable latex proteins in dipped rubber products. It is a major concern for the consumers who are sensitive to the allergenic extractable proteins (EP) in products such as NRL gloves. Objective of this research was to develop an economical method to reduce the EP in finished dipped NRL products. In order to reduce the EP levels, two natural proteases, bromelain from pineapple and papain from papaya, were extracted and partially purified using (NH4)2SO4. According to the newly developed method, different glove samples were treated with a 5% solution of each partially purified enzyme, for 2 hours at 60°C. Residual amounts of in treated samples were quantified using the modified Lowry assay (ASTM D5712-10). Bromelain displayed a 54 (±11)% reduction of the EP from the dipped rubber products, whereas it was 58 (±8)% with papain. These results clearly indicate that the selected natural proteases, bromelain, and papain contribute significantly towards the reduction of the total EP in finished NRL products. Application of bromelain enzyme for the aforementioned purpose has not been reported up to date, whereas papain has been used to treat raw NRL towards reducing the EP. PMID:28706952
Method for forming a glove attachment
NASA Technical Reports Server (NTRS)
Dawn, Frederic S. (Inventor); Guy, Walter W. (Inventor); Kosmo, Joseph (Inventor); Drennan, Arthur P. (Inventor); Tschirch, Richard P. (Inventor)
1995-01-01
An attachment principally for the palm of an astronaut glove to enhance the gripping area of the palm without detracting from the flexibility and utility of the glove is presented. The attachment is a composite construction formed from a layer of silicone rubber having an outer surface with a friction configuration and another layer of silicone rubber in which a Nomex Aramid mesh fabric is embedded prior to curing. The method of construction involves the use of a mold with a friction configuration surface. A first layer of silicone rubber or sealant is disposed in the mold and allowed to set for an hour. A second layer of silicone rubber or sealant is layered over the first layer and leveled. A Nomex Aramid mesh fabric is embedded into the second layer and the composite is permitted to cure. When cured, a configured area of the composite construction is glued or stitched to the palm area of the glove.
NASA Astrophysics Data System (ADS)
Keangin, P.; Narumitbowonkul, U.; Rattanadecho, P.
2018-01-01
Natural rubber (NR) is the key raw material used in the manufacture of other products such as rubber band, tire and shoes. Recently, the NR is used in natural rubber glove ( NRG) manufacturing in the industrial and medical fields. This research aims to investigate the electromagnetic wave propagation and heat transfer in NRG due to heating with microwave energy within the microwave oven at a microwave frequency of 2.45 GHz. Three-dimensional model of NRG and microwave oven are considered in this work. The comparative effects of waveguide position on the electric field and temperature profile in NRG when subjected to microwave energy are discussed. The finite element method (FEM) is used to solve the transient Maxwell’s equation coupled with the transient heat transfer equation. The simulation results with computer programs are validated with experimental results. The placement of waveguides in three cases are left hand side of microwave oven, right hand side of microwave oven and left and right hand sides of microwave oven are investigated. The findings revealed that the placing the waveguide on the right side of the microwave oven gives the highest electric field and temperature profile. The values obtained provide an indication toward understanding the study of heat transfer in NRG during microwave heating in the industry.
NASA Astrophysics Data System (ADS)
Vinches, L.; Peyrot, C.; Lemarchand, L.; Boutrigue, N.; Zemzem, M.; Wilkinson, K. J.; Hallé, S.; Tufenkji, N.
2015-05-01
Parallel to the increased use of engineered nanoparticles (ENP) in the formulation of commercial products or in medicine, numerous health & safety agencies have recommended the application of the precautionary principle to handle ENP; namely, the recommendation to use protective gloves against chemicals. However, recent studies reveal the penetration of titanium dioxide nanoparticles through nitrile rubber protective gloves in conditions simulating occupational use. This project is designed to understand the links between the penetration of gold nanoparticles (nAu) through nitrile rubber protective gloves and the mechanical and physical behaviour of the elastomer material subjected to conditions simulating occupational use (i.e., mechanical deformations (MD) and sweat). Preliminary analyses show that nAu suspensions penetrate selected glove materials after exposure to prolonged (3 hours) dynamic deformations. Significant morphological changes are observed on the outer surface of the glove sample; namely, the number and the surface of the micropores on the surface increase. Moreover, nitrile rubber protective gloves are also shown to be sensitive to the action of nAu suspension and to the action of the saline solution used to simulate sweat (swelling).
Natural rubber latex allergy and asthma.
Tarlo, S M
2001-01-01
Allergic responses to natural rubber latex (NRL) continue to be reported. In adults, the major exposure is in the occupational setting, especially in relation to NRL glove use by health care workers. Issues addressed over the past year include improving diagnostic methods for NRL allergy and characterization of NRL allergens relevant to various exposure groups and evaluating strategies for prevention and early detection of NRL allergy. Assessment of in vitro tests show good intertest correlation but lower sensitivity compared with skin test responses. NRL allergens have been further characterized as reported in the past year. Development of recombinant Hev b 3, a major NRL allergen relevant to children with spina bifida, enhances the likelihood for improved diagnostic reagents. Preliminary reports of primary preventive strategies suggest that avoidance of high-protein, powdered gloves in health care facilities can be cost-effective and is associated with a decline in sensitized workers.
Allmers, Henning; Schmengler, Jörg; Skudlik, Christoph
2002-08-01
The development of occupational asthma and allergic skin reactions caused by natural rubber latex (NRL) allergy are risks for health care workers. There are few published studies to suggest that intervention programs to reduce exposure will lead to primary prevention of sensitization. This study assesses the effects of intervention to reduce the incidence of NRL allergy in personnel working in health care facilities insured by the German statutory accident insurance company for health care workers, Berufsgenossenschaft für Gesundheitsdienst und Wohlfahrtspflege, with approximately 3 million insured employees, by switching to powder-free NRL gloves. The timing of introduction of intervention strategies, such as education of both physicians and administrators, together with regulations demanding that health care facilities only purchase low-protein, powder-free NRL gloves are reported. We reviewed the annual numbers of reported suspected cases of NRL-caused occupational allergies and the amount and type of gloves used in German acute-care hospitals since 1986. The purchase of powder-free NRL examination gloves exceeded that of powdered gloves for the first time in 1998. This only became true for powder-free NRL sterile gloves 2 years later in 2000. The incidence of suspected occupational NRL allergy cases rose until 1998 and has declined steadily since. There was a 2-year lag between the beginning of the decline in the purchase of powdered NRL examination gloves and the beginning of a decline in suspected NRL-caused occupational asthma cases. Despite the effect of increased recognition of NRL allergies, education about NRL allergies in health care facilities combined with the introduction of powder-free gloves with reduced protein levels has been associated with a decline in the number of suspected cases of occupational allergies caused by NRL in Germany on a nationwide scale. These results clearly indicate that primary prevention of occupational NRL allergies can be achieved if these straightforward and practical interventions are properly carried out and maintained.
Liss, G M; Tarlo, S M
2001-10-01
Exposure to natural rubber latex (NRL) has been recognized as a cause of occupational asthma (OA), especially among health care workers (HCWs) associated with use of gloves. Little or no population-based data are available which chart the changes over time in the number of cases of OA as this problem was increasingly recognized and then interventions instituted. We obtained the numbers of allowed asthma claims with exposure to latex by year in the province of Ontario, Canada from the Ontario Workplace Safety and Insurance Board; details of the cases from the largest teaching hospital were reviewed. Interventions included: (1) in 1996, the Board recommended in its focus for accommodation of sensitized workers, the reduction of aerosols of latex proteins and that hospital facilities use powder-free, low-protein or nonlatex gloves; and (2) hospitals instituted latex policies and glove changes at various dates. For example, at the largest teaching hospital, interventions included education and voluntary medical surveillance in 1994; substitution of low protein, "powder-free" NRL gloves for non-sterile powdered gloves in 1995; and replacement of powdered sterile NRL gloves by lower protein, "powder-free" NRL gloves in 1997. Through 1999, there were 60 allowed claims for asthma in Ontario with exposure to latex; of these 49 (82%) were among HCWs. The number of claims among HCWs changed from 0 to 2 per year up to 1990; increased to 7 to 11 per year between 1991-1994; and declined to 3 per year in 1995-1996 and 1 to 2 per year in 1997-1999. Of the ten institutions having two or more OA latex claims, all claims occurred in 1996 or earlier at 8 (80%). At the largest hospital, there were five accepted claims with year of diagnosis in 1993 (1 case), 1994 (3 cases), and 1995 (1 case). These findings suggest that, despite the effect of increasing recognition, the introduction of gloves with reduced powder and/or protein, as well as other interventions have been associated temporally with declines in the number of cases of latex OA. Copyright 2001 Wiley-Liss, Inc.
1980-07-01
Edmont-Wilson 37-165 NBR .056 (22) 10 J Edmont-Wilson 26-665 Rubber .046 (18) 10 K Edmont-Wilson 36-755 Rubber .102 (40) 10 L Surety 10-112L Nitrile...4367 Dickenson & Company Charleston SC 29405 Coshocton OH 43812 International Playtex Company Surety Rubber Company Industrial Gloves Division P.O. Box...B Pioneer A-10 Nitrile .025 (10) 9 C Pioneer A-15 Nitrile .038 (15) 9 D Norton NSN 8415-00-753-6551 Butyl rubber .076 (30) M E Norton NSN 8415-01-025
The power of glove: Soft microbial fuel cell for low-power electronics
NASA Astrophysics Data System (ADS)
Winfield, Jonathan; Chambers, Lily D.; Stinchcombe, Andrew; Rossiter, Jonathan; Ieropoulos, Ioannis
2014-03-01
A novel, soft microbial fuel cell (MFC) has been constructed using the finger-piece of a standard laboratory natural rubber latex glove. The natural rubber serves as structural and proton exchange material whilst untreated carbon veil is used for the anode. A soft, conductive, synthetic latex cathode is developed that coats the outside of the glove. This inexpensive, lightweight reactor can without any external power supply, start up and energise a power management system (PMS), which steps-up the MFC output (0.06-0.17 V) to practical levels for operating electronic devices (>3 V). The MFC is able to operate for up to 4 days on just 2 mL of feedstock (synthetic tryptone yeast extract) without any cathode hydration. The MFC responds immediately to changes in fuel-type when the introduction of urine accelerates the cycling times (35 vs. 50 min for charge/discharge) of the MFC and PMS. Following starvation periods of up to 60 h at 0 mV the MFC is able to cold start the PMS simply with the addition of 2 mL fresh feedstock. These findings demonstrate that cheap MFCs can be developed as sole power sources and in conjunction with advancements in ultra-low power electronics, can practically operate small electrical devices.
2007-06-01
Joint At the exit of the expansion tank, a polymeric composition of ethylene-propylene- diene terpolymer ( EPDM ) rubber was used to mate the flange of...The final connection of the detonator was cumbersome for an operator wearing thick butyl rubber gloves. The detonator wire connection was made to a...operators were required to wear PPE, including rubber gloves. The decision was made to transfer the PLC components to outside the VCS. In Phase I, the
Linos, Alexandros; Berekaa, Mahmoud M.; Reichelt, Rudolf; Keller, Ulrike; Schmitt, Jürgen; Flemming, Hans-Curt; Kroppenstedt, Reiner M.; Steinbüchel, Alexander
2000-01-01
Several actinomycetes isolated from nature were able to use both natural rubber (NR) and synthetic cis-1,4-polyisoprene rubber (IR) as a sole source of carbon. According to their degradation behavior, they were divided into two groups. Representatives of the first group grew only in direct contact to the rubber substrate and led to considerable disintegration of the material during cultivation. The second group consisted of weaker rubber decomposers that did not grow adhesively, as indicated by the formation of clear zones (translucent halos) around bacterial colonies after cultivation on NR dispersed in mineral agar. Taxonomic analysis of four selected strains based on 16S rRNA similarity examinations revealed two Gordonia sp. strains, VH2 and Kb2, and one Mycobacterium fortuitum strain, NF4, belonging to the first group as well as one Micromonospora aurantiaca strain, W2b, belonging to the second group. Schiff's reagent staining tests performed for each of the strains indicated colonization of the rubber surface, formation of a bacterial biofilm, and occurrence of compounds containing aldehyde groups during cultivation with NR latex gloves. Detailed analysis by means of scanning electron microscopy yielded further evidence for the two different microbial strategies and clarified the colonization efficiency. Thereby, strains VH2, Kb2, and NF4 directly adhered to and merged into the rubber material, while strain W2b produced mycelial corridors, especially on the surface of IR. Fourier transform infrared spectroscopy comprising the attenuated total reflectance technique was applied on NR latex gloves overgrown by cells of the Gordonia strains, which were the strongest rubber decomposers. Spectra demonstrated the decrease in number of cis-1,4 double bonds, the formation of carbonyl groups, and the change of the overall chemical environment, indicating that an oxidative attack at the double bond is the first metabolic step of the biodegradation process. PMID:10742254
Micropunctures of rubber gloves used in oral surgery.
Skaug, N
1976-10-01
In 720 operations in ambulatory oral surgery, the 2,880 surgical rubber gloves used were tested at the end of operation for perforations not earlier detected (microperforations). Gloves of ordinary thickness (type A) and of a thicker quality (type B) were examined. Perforations were found in 1495% and 22.0% of type A gloves and in 3.2% and 2.0% of type B gloves when oral surgeons and dental students, respectively, were operators. Gloves worn by operation assistants showed a lower incidence of perforation. Before operation, 50 gloves of type A were punctured at the tip of right index finger by a sterile dental probe. Results of bacteriologic examinations of the right index and middle fingers strongly indicated that a high number of bacteria passed through pinholes in the gloves. The intact surgical glove represents an impermeable barrier, protecting not only the operation wound against skin bacteria from the hands of the oral surgeon, but also the oral surgeon against pathogenic microorganisms, in particular hepatitis virus type B, escaping from the oral cavity of the patient.
Pontén, Ann; Hamnerius, Nils; Bruze, Magnus; Hansson, Christer; Persson, Christina; Svedman, Cecilia; Thörneby Andersson, Kirsten; Bergendorff, Ola
2013-02-01
An increased frequency of occupational contact hand dermatitis among surgical operating theatre personnel has been noticed. To evaluate patients with occupational contact dermatitis caused by their rubber gloves, and to describe a method for analysing the content of the allergens in the gloves. Patch tests were performed with the baseline series, a rubber chemical series, and the patients' own gloves. A method for analysing 1,3-diphenylguanidine (DPG) and cetylpyridinium chloride in the gloves was developed. Contact allergy to thiuram mix was found in 8 of 16 patients, whereas 12 of 16 patients reacted to DPG. In 7 of 8 patients, contact allergy to cetylpyridinium chloride was found. In the patients' gloves, cetylpyridinium chloride and DPG were detected at higher concentrations on the inside of the gloves than on the outside. Most patients had worked for decades in their present occupations, but their hand dermatitis had only been present for months. Contact allergy to DPG in gloves has been disputed, but, in this study, we were able to confirm the presence of DPG and cetylpyridinium chloride in the causative gloves by using a modified method for the analysis. The presence of these chemicals in gloves caused an increase in occupational contact dermatitis in surgical operating theatre personnel. © 2012 John Wiley & Sons A/S.
Krzemińska, Sylwia; Rzymski, Władysław M.; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz
2016-01-01
Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile–butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves. PMID:26757889
16 CFR 1630.4 - Test procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the...) Gloves. Nonhygroscopic gloves (such as rubber polyethylene) for handling the sample after drying, and...
16 CFR 1631.4 - Test procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the... gel desiccant. (7) Gloves. Nonhygroscopic gloves (such as rubber or polyethylene) for handling the...
16 CFR 1630.4 - Test procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the...) Gloves. Nonhygroscopic gloves (such as rubber polyethylene) for handling the sample after drying, and...
16 CFR 1631.4 - Test procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... a fire-retardant treatment, or is made of fibers which have had a fire-retardant treatment, the... gel desiccant. (7) Gloves. Nonhygroscopic gloves (such as rubber or polyethylene) for handling the...
Mäkelä, Erja A; Vainiotalo, Sinikka; Peltonen, Kimmo
2003-06-01
Standard test methods ASTM F739 and EN 374 were compared by assessing the permeation of 70% isopropyl alcohol (2-propanol) through seven brands of surgical gloves. The two standards differ in the flow rates of the collection medium and in the chemical permeation rate at which the breakthrough time (BTT) is detected, the EN detection level being 10 times higher than the permeation rate used by ASTM. In a departure from the EN standard method, a 4 h testing time was used instead of 8 h. All of the tested gloves were from the same manufacturer and were made from either natural rubber (NR) (six brands) or chloroprene rubber (CR) (one brand). Two of the NR glove brands were double layered. For the thin NR gloves (0.22, 0.28 and 0.27 mm) the permeation rates were higher throughout the tests with a flow rate of 474 ml/min (EN) of the collection medium (nitrogen) compared with the permeation rates obtained with a flow rate of 52 ml/min (ASTM). These resulted in BTTs of 4.6, 6.5 and 7.6 min (EN) and 4.8, 6.5 and 9.1 min (ASTM), respectively. No statistical difference could be observed between the BTT values obtained with the two standard methods for any of the thin gloves. Thus, although the ASTM standard has a lower criterion for the detection of permeation, it does not necessarily produce shorter BTTs. For the better barriers the methods yielded more equivalent permeation rate curves and thus the EN BTTs were longer than the ASTM BTTs: the EN results were 21, 80, 122 and >240 min compared with the ASTM results of 12, 32, 38 and 103 min for glove thicknesses of 0.37 (NR), 0.22 + 0.22 (double layered NR), 0.31 + 0.29 (double layered NR) and 0.19 mm (CR), respectively.
1982-02-08
S82-26645 (March 1982) --- Spacesuit inner gloves consist of pressure bladders covered by Beta Cloth. EVA outer gloves are made of Beta Cloth, Mylar and a metallic mesh hand area. The thumb and fingertips of the glove are molded of silicone rubber to permit a degree of sensitivity. The inner gloves attach to the suit by pressure sealing rings, similar to these used in helmet-to-suit connections. The outer gloves served as a cover to protect from micrometeorites, abrasions and heat.
Hamnerius, Nils; Svedman, Cecilia; Bergendorff, Ola; Björk, Jonas; Bruze, Magnus; Engfeldt, Malin; Pontén, Ann
2018-06-20
Hand eczema (HE) in healthcare workers (HCWs) is common. Besides wet work, healthcare work also implies exposure to contact allergens. To assess HE and contact allergy related to occupational exposures in HCWs. In a cross-sectional study, 311 HCWs with HE within the preceding 12 months and a control group of 114 HCWs without HE were investigated with the baseline series and a special patch test series based on substances found in the gloves, soaps, alcoholic hand disinfectants and hand creams provided at the hospitals. Contact allergy to rubber additives was significantly more common in HCWs with HE (6%) than in HCWs without HE (1%, P = .02). The corresponding percentages for fragrances were 11% and 3%, respectively (P = .004). Occupational HE was found in 193 of 311 (62%) HCWs. Of these, 22 of 193 (11%) had occupational allergic contact dermatitis, including 17 with glove-related rubber contact allergy. Contact allergy to diphenylguanidine was as common as contact allergy to thiurams. Occupational contact allergy to rubber additives was significantly associated with sick-leave related to HE. Contact allergy to rubber additives in medical gloves is the most common cause of occupational allergic contact dermatitis in HCWs. Aimed patch testing with relevant rubber additives is mandatory when HE in HCWs is investigated. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Development of hand exoskeleton for rehabilitation of post-stroke patient
NASA Astrophysics Data System (ADS)
Zaid, Amran Mohd; Chean, Tee Chu; Sukor, Jumadi Abdul; Hanafi, Dirman
2017-10-01
Degenerative muscle diseases characterized by loss of strength in human hand significantly affect the physical of affected individuals. A soft assistive exoskeleton glove is designed to help post-stroke patient with their rehabilitation process. The glove uses soft bending actuator which has a rubber like tender characteristic. Due to its rubber like characteristic, flexion of finger can be achieved easily through pneumatic air without considering other hand motions. The application involves a post-stroke patient to wear the soft exoskeleton glove on his paralyzed hand and control the actuation of the glove by using pneumatic air source. The fabrication of the soft bending actuator involves silicone rubber Mold Star® 15 SLOW which falls within the soft category of shore A hardness scale. The soft bending actuator is controlled by Arduino Mega 2560 as main controller board and relay module is used to trigger the 3/2-way single solenoid valve by switching on the 24VDC power supply. The actuation of the soft bending actuator can be manipulated by setting delay ON and OFF for the relay switching. Thus, the repetition of the bending motion can be customized to fulfil the rehabilitation needs of the patient.
[Old and new types of sanitary gloves: what has improved?].
Belleri, L; Crippa, Michela
2008-01-01
During the eighties a large increase in latex gloves production was observed because of the high demand of gloves in health care settings. In this period a low compliance to minimal quality standard was detected and the poor glove quality was associated with an increase of both irritant and allergic glove-related diseases. Since the second half of nineties health care workers and manufacturers paid more attention to these problems and a trend to a gradual, even if slow, quality improvement was observed. Most frequently powder-free gloves and synthetic gloves were offered on the market. The aim of this study was to highlight what has improved about materials and types of sanitary gloves during the last ten years. The information are based on a review of the scientific literature and practical experiences. Today a large selection of gloves made of different materials are available and they should be addressed to specific tasks. The review of the scientific literature and the analysis of many technical sheets provided by the manufacturers pointed out a trend to a better latex gloves quality (less chemical additives and generally a lower total protein content); sometimes data about a lower extractable latex allergens content are also available. Unfortunately detailed information on glove composition are not usually provided by the manufacturers; purchasers should require the manufacturing company to give comprehensive information and verify their reliability. Moreover the regulation in force should be adapted to higher quality standards. Powder-free and synthetic gloves consumption has improved but the use of synthetic rubber gloves should be further enhanced since some materials (e.g. neoprene and nitrile rubber) have a good biocompatibility and seem to have physical properties and protective efficacy similar to latex. Moreover allergic reactions to synthetic gloves (some chemical additives) are only occasional.
A review of natural-rubber latex allergy in health care workers.
Ranta, Peter M; Ownby, Dennis R
2004-01-15
This brief review of natural-rubber latex (NRL) allergy in health care workers (HCWs) includes the definition of NRL allergy and data on its epidemiology, pathogenesis, diagnostic algorithm, management, long-term outcomes, economic impact, cost-effectiveness of changing facilities to a latex-free environment, and prevention. The data presented suggest that an individual with type I or type IV hypersensitivity to NRL should be able to continue to work in the workplace with careful evaluation and reasonable accommodations. Reducing exposure to latex is a safe and more economical alternative to complete removal of the individual from the place of employment. The use of low-allergen, nonpowdered NRL gloves substantially reduces airborne exposure to latex in most health care settings.
Sensitization to Rubber Accelerators in Northeastern Italy: The Triveneto Patch Test Database.
Buttazzo, Silvia; Prodi, Andrea; Fortina, Anna Belloni; Corradin, Maria Teresa; Larese Filon, Francesca
2016-01-01
Natural and synthetic rubbers containing rubber accelerators are well-known causes of occupational skin disease. Allergic contact dermatitis caused by rubber gloves is frequent and has almost exclusively been attributed to contact sensitization to accelerators. This study aimed to evaluate the frequency of rubber accelerators sensitization in the population living in northeastern Italy, to find time trend and a correlation with occupations, and to investigate co-sensitization between rubber accelerators. A population of 23,774 subjects was patch tested in 6 cities in northeastern Italy in the years 1996 to 2012 using carba mix 3%, thiuram mix 1%, benzothiazole (MBT) mix 1%, and isopropyl phenyl paraphenylamine diamine (IPPD) mix 0.6%. The overall frequency of carbamates, MBT, thiurams, and IPPD mix sensitization was 3.4%, 0.65%, 1.75%, and 0.83%, respectively. On a logistic regression analysis (control group: white-collar workers), we found a statistically significant association to carbamates (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.03-1.7) and thiurams (OR, 1.6; 95% CI, 1.1-2.3) for health care workers. Thiuram sensitivity was also significantly associated with dermatitis in maids and restaurant workers (OR, 2.2; 95% CI, 1.4-3.6), hairdressers (OR, 3.6; 95% CI, 1.8-7.1), shop assistants (OR, 2.9; 95% CI, 1.2-6.8), construction workers (OR, 2.7; 95% CI, 1.7-4.1), mechanics (OR, 2.1; 95% CI, 1.3-3.4), and professional drivers (OR, 2.6; 95% CI, 1.2-5.9). In conclusion, our results demonstrated that rubber accelerators have an important role in allergic contact dermatitis in the northeast of Italy and their sensitization is associated significantly with occupations that wear gloves or use chemical substances. Between rubber accelerators tested, carbamates sensitization is prevalent and increasing during considered years.
Chang, H; Lin, C; Shih, T; Chan, H; Chou, J; Huang, Y
2004-01-01
Aims: To evaluate the protective effectiveness of gloves from occupational exposure to 2-methoxyethanol (2-ME); and to examine the association of 2-methoxyacetic acid (MAA) in urine and plasma collected simultaneously from low 2-ME exposure and high 2-ME exposure workers in a semiconductor copper laminate circuit board manufacturing plant. Methods: Eight hour time weighted breathing zone monitoring was performed to verify the 2-ME exposure classification between workers in regular and special operations. Urine and plasma samples were simultaneously collected from 74 exposed and 80 non-exposed workers. MAA concentrations in the urine (UMAA) and plasma (PMAA) were measured using previously published methods. Three types of gloves worn by workers (cotton, rubber, and no gloves) were recorded by direct observations in the workplace and validated by person-to-person interview. Protective effectiveness indices (PEI) were used to evaluate the glove effectiveness. Results: There was no detectable 2-ME/MAA in the air, or in urine and plasma samples in non-exposed workers. The average UMAA and PMAA in special operations were 72.63 mg/g Cr. and 29.72 mg/l, significantly higher than values in regular operations (5.44 mg/g Cr. and 2.58 mg/l, respectively). PMAA showed satisfactory correlation to UMAA in all participants from both regular and special operations. The rubber gloves provided significant reduction in 2-ME uptake, whereas cotton gloves provided little protection with fluctuating effectiveness, based on PEI estimates. Conclusions: PMAA, similar to UMAA, could serve as a specific biomarker for 2-ME exposure. Wearing impermeable rubber gloves during high risk tasks can reduce major 2-ME exposure. Other improvements, including engineering control, should be provided to diminish worker exposure to 2-ME in occupational environments. PMID:15258277
Composite Material Hazard Assessment at Crash Sites
2015-01-01
advanced composite materials. All personnel involved in rescue in close crash-site proximity are required to wear self -contained breathing apparatus...close crash-site proximity are required to wear self -contained breathing apparatus, chemical protective clothing, leather gloves, and neoprene...Take extra precaution when handling these materials. Nitrile rubber gloves can be worn underneath the leather gloves to provide chemical hazard
2017-01-01
Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves. PMID:29207573
Glove-related rhinopathy among hospital personnel.
Kujala, V M; Reijula, K E
1996-08-01
Hypersensitivity to natural rubber latex (NRL) in health care personnel exposed to powdered latex gloves appears as conjunctivitis, rhinitis, nasal congestion, cough, dyspnea, or bronchial asthma in approximately 30% of all cases with latex allergy while most of the patients have contact urticaria. The purpose of the present study was to determine the prevalence of latex-induced allergic rhinitis in health care workers using NRL gloves on a daily basis. Clinical examination accompanied by skin prick test (SPT) with latex glove extracts and common aeroallergens, measurements of specific IgE to NRL, and lung function tests were performed in 25 symptomatic workers and 11 latex-exposed asymptomatic controls. Sensitization to NRL was detected using SPT in one (4%) of 25 symptomatic workers but not in any of the asymptomatic controls. Positive SPT to aeroallergens was demonstrated in 8/25 symptomatic workers and 6/11 controls. Measurements of forced vital capacity, forced expiratory volume in I sec, and bronchial methacholine challenge did not show any significant differences between the study groups. In conclusion, NRL-aeroallergen-induced occupational rhinitis may occur among physicians and nurses who have a frequent use of latex gloves on a daily basis at hospital work. However, a relatively low prevalence of NRL-induced occupational rhinitis is associated with profuse consumption of no-powder sterile gloves.
The use of powdered gloves in dental practice: a cause for concern?
Field, E A
1997-01-01
To critically review the potential hazards associated with the use of powdered, natural rubber latex (NRL) gloves in dental practice and to report some practical difficulties which may be encountered when handling dental materials with powdered NRL gloves. Articles published in the international literature over the last 10 years. A number of recent studies in the medical and surgical literature have confirmed that NRL proteins leach out of latex gloves and bind to surgical glove powders. The most serious, potential hazard associated with the continued use of powdered NRL gloves in dental practice is that of latex sensitization by exposure to aerosolized NRL proteins. Hand dermatitis is now recognized as an occupational hazard in dentistry and has been associated with the continuous wearing of protective gloves. Studies, in the dermatological literature, have suggested that glove powders may exacerbate an irritant dermatitis and enhance the potential for adverse reactions to other components of NRL gloves. The surgical literature has already highlighted the risks of post-operative granuloma formation, due to glove powder contamination of the surgical wound. The possible effects of powder contamination of dental implant sites, on the outcome and success of implants has yet to be established. Recent in vitro studies have investigated the effect of latex glove contamination on the shear-bond strength of porcelain laminate veneers: one study demonstrated that starch powder significantly affected the bond strength, whereas the other showed that latex glove contamination of the porcelain surface did not have any significant effect. Long-term, in vivo studies are now required. Dental practitioners should consider the potential health risks which are associated with the use of powdered NRL in dental practice. Powder contamination may affect the long-term results and success of clinical procedures in dentistry.
Estimation of shelf life of natural rubber latex exam-gloves based on creep behavior.
Das, Srilekha Sarkar; Schroeder, Leroy W
2008-05-01
Samples of full-length glove-fingers cut from chlorinated and nonchlorinated latex medical examination gloves were aged for various times at several fixed temperatures and 25% relative humidity. Creep testing was performed using an applied stress of 50 kPa on rectangular specimens (10 mm x 8 mm) of aged and unaged glove fingers as an assessment of glove loosening during usage. Variations in creep curves obtained were compared to determine the threshold aging time when the amount of creep became larger than the initial value. These times were then used in various models to estimate shelf lives at lower temperatures. Several different methods of extrapolation were used for shelf-life estimation and comparison. Neither Q-factor nor Arrhenius activation energies, as calculated from 10 degrees C interval shift factors, were constant over the temperature range; in fact, both decreased at lower temperatures. Values of Q-factor and activation energies predicted up to 5 years of shelf life. Predictions are more sensitive to values of activation energy as the storage temperature departs from the experimental aging data. Averaging techniques for prediction of average activation energy predicted the longest shelf life as the curvature is reduced. Copyright 2007 Wiley Periodicals, Inc.
Talimogene Laherparepvec Injection
... sure to replace them right away. You should use rubber or latex gloves when bandaging the injection sites. You should be sure to put all cleaning materials, gloves, and bandages that were used for the injection sites into a sealed plastic bag and throw them away into the garbage.you ...
Electricity remains a serious workplace hazard.
Proctor, Laura; Kuchibotla, Srin
2013-08-01
Anyone who works in an industrial environment or is employed in the utility, mass transit, industrial goods manufacturing, or telecommunications industry - as well as many others - may be at risk for electrocution. Electric shock costs workers' lives and results in painful and debilitating injuries every year. Lockout/tagout procedures protect against electrocution, as do rubber insulating gloves, which must be worn any time workers are exposed to energized parts operating at 50 volts or higher. Some newer styles of rubber insulating gloves not only protect against electric shock, but also offer the dexterity and flexibility workers need for hours of comfortable wear.
Vandenplas, O; Larbanois, A; Vanassche, F; François, S; Jamart, J; Vandeweerdt, M; Thimpont, J
2009-03-01
Natural rubber latex (NRL) has become as a major cause of occupational asthma (OA) in workers using NRL gloves. Few population-based studies have assessed the impact of changes in the patterns of glove usage on the incidence of NRL-induced OA. To characterize the time trends in incident cases of NRL-induced OA in Belgium and examine whether incidence rates were related to the types of gloves used in hospitals. Incident cases of NRL-induced OA were identified through a retrospective review of all claims submitted to the Workers' Compensation Board up to December 2004. Based on the results of diagnostic procedures, the diagnosis of NRL-induced OA was categorized as definite, probable, unlikely, or indeterminate. The patterns of glove usage were characterized through a questionnaire survey of Belgian hospitals. A total of 298 claims for NRL-induced OA were identified, including 127 subjects with definite OA and 68 with probable OA. Categorized by the year of asthma onset, the incident cases of definite and probable NRL-induced OA markedly decreased from 1999 onwards. The use of powdered NRL gloves fell from 80.9% in 1989 to 17.9% in 2004. Powdered NRL gloves were predominantly substituted with NRL-free gloves, especially in the case of non-sterile procedures. These national compensation-based data confirm that a persistent decline in the incidence of NRL-induced OA has occurred since late 1990s. This downward trend has temporally been associated with a decreasing usage of powdered NRL, further supporting a beneficial role of changes in glove policies.
Atypical pattern of (meth)acrylate allergic contact dermatitis in dental professionals.
Prasad Hunasehally, R Y; Hughes, T M; Stone, N M
2012-09-01
(Meth)acrylates in dental bonding agents are a common source of allergic contact dermatitis in dental professionals. The distribution of the contact dermatitis is commonly on finger tips, but is determined by individual habits as demonstrated by the two case reports in this article. Despite the site of contact dermatitis, the bonding agents are often not suspected as a source of contact allergy due to misconception regarding the protective effect of natural rubber latex gloves. With these case reports, we endeavour to emphasize the inadequacy of the latex gloves in protecting against the (meth)acrylate induced contact allergy and also list the measures a dental professional needs to incorporate in order to minimise the risks of sensitisation to (meth)acrylates.
Brackenbush, L.W.; Hoenes, G.R.
A shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user wthdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.
[Identification of migrants from nitrile-butadiene rubber gloves].
Mutsuga, Motoh; Kawamura, Yoko; Wakui, Chiseko; Maitani, Tamio
2003-04-01
Polyvinyl chloride gloves containing di(2-ethylhexyl) phthalate are restricted for food contact use. In their place, disposable gloves made from nitrile-butadiene rubber (NBR) are used in contact with foodstuffs. Some unknown substances were found to migrate into n-heptane from NBR gloves. By GC/MS, HR-MS and NMR, their chemical structures were confirmed to be 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (used as a plasticizer), 4,4'-butylidenedi(6-tert-butyl-m-cresol), a mixture of styrenated phenols consisting of 2-(alpha-methylbenzyl)phenol, 4-(alpha-methylbenzyl)phenol, 2,6-di(alpha-methylbenzyl)phenol, 2,4-di(alpha-methylbenzyl)phenol and 2,4,6-tri(alpha-methylbenzyl)phenol (used as antioxidants), and 2,4-di-tert-butylphenol, which seems to a degradation product of antioxidant. Migration levels of these compounds were 1.68 micrograms/cm2 of 2,4-di-tert-butylphenol, 2.80 micrograms/cm2 of 2,2,4-trimethyl-1,3-pentanediol diisobutyrate, 46.08 micrograms/cm2 of styrenated phenols and 4.22 micrograms/cm2 of 4,4'-butylidenedi(6-tert-butyl-m-cresol) into n-heptane, respectively. The content of total styrenated phenols was 6,900 micrograms/g in NBR gloves.
Biologically Active Zone Enhancement (BAZE) for In Situ RDX Degradation in Ground Water
2010-01-01
geotechnical laboratory testing, will be performed in Level D protection with the addition of chemical resistant gloves. The level of protection for...splash hazards), • Chemical- resistant boots (PVC, Neoprene, Rubber) or work boots with covers ( steel-toed as appropriate), • Inner gloves (latex or...vinyl), • Outer, chemical- resistant gloves (nitrile, PVC, Neoprene), • Safety glasses or goggles, • Hard hat (as required by OSHA), and • Splash
Degradation of polyisoprene rubber by newly isolated Bacillus sp. AF-666 from soil.
Shah, A A; Hasan, F; Shah, Z; Mutiullah; Hameed, A
2012-01-01
Various microorganisms were screened for their ability to degrade polyisoprene rubber (natural rubber latex gloves). Strain AF-666, newly isolated from a soil sample, was selected as the best strain having the ability to grow on polyisoprene containing plates. The strain identified as Bacillus sp. AF-666, was found to degrade polyisoprene rubber, both on basal agar plates (latex overlay) as well as in liquid medium. Qualitative analysis of degradation was done through scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy SEM showed changes in surface morphology, like appearance of pits and cracks, and marked difference in transmittance spectra of test and control due to changes in the functional groups, was detected through FTIR. CO2 evolution as a result of rubber degradation, was calculated gravimetrically by Sturm Test. About 4.43 g/1 of CO2 was produced in case of test, whereas, 1.57 g/1 in case of control. The viable number of cells (CFU/ml) was also higher in test than in control. Present study may provide an opportunity for further studies on the applications of biotechnological processes as a tool for rubber waste management.
Phalen, R N; Que Hee, Shane S
2007-02-01
The aim of this study was to investigate the surface variability of 13 powder-free, unlined, and unsupported nitrile rubber gloves using attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrophotometry at key wavelengths for analysis of captan contamination. The within-glove, within-lot, and between-lot variability was measured at 740, 1124, 1252, and 1735 cm(-1), the characteristic captan reflectance minima wavelengths. Three glove brands were assessed after conditioning overnight at relative humidity (RH) values ranging from 2 +/- 1 to 87 +/- 4% and temperatures ranging from -8.6 +/- 0.7 to 59.2 +/- 0.9 degrees C. For all gloves, 1735 cm(-1) provided the lowest background absorbance and greatest potential sensitivity for captan analysis on the outer glove surface: absorbances ranged from 0.0074 +/- 0.0005 (Microflex) to 0.0195 +/- 0.0024 (SafeSkin); average within-glove coefficients of variation (CV) ranged from 2.7% (Best, range 0.9-5.3%) to 10% (SafeSkin, 1.2-17%); within-glove CVs greater than 10% were for one brand (SafeSkin); within-lot CVs ranged from 2.8% (Best N-Dex) to 28% (SafeSkin Blue); and between-lot variation was statistically significant (p < or = 0.05) for all but two SafeSkin lots. The RH had variable effects dependent on wavelength, being minimal at 1735, 1252, and 1124 cm(-1) and highest at 3430 cm(-1) (O-H stretch region). There was no significant effect of temperature conditioning. Substantial within-glove, within-lot, and between-lot variability was observed. Thus, surface analysis using ATR-FT-IR must treat glove brands and lots as different. ATR-FT-IR proved to be a useful real-time analytical tool for measuring glove variability, detecting surface humidity effects, and choosing selective and sensitive wavelengths for analysis of nonvolatile surface contaminants.
Lee, Hsiao-Shu; Lin, Yu-Wen
2009-04-01
Skin irritation and contact allergies are skin disorders common to hairdressers. The predominant oxidative hair dye components, such as p-phenylenediamine (PPD) and aminophenol isomers, can cause contact dermatitis. Use of protective gloves can prevent dermal contact with skin irritants. This study investigates the permeation behaviors of p-aminophenol (PAP), m-aminophenol (MAP), o-aminophenol (OAP) and PPD in single and mixed challenge solutions with disposable natural rubber latex (NRL) gloves, disposable polyvinylchloride (PVC) gloves and neoprene (NP) gloves. The challenge solutions were 4% PPD (w/v), 3% OAP (w/v), 2% PAP (w/v) and 2% MAP (w/v) in ethanol or 12% hydrogen peroxide solutions. The cocktail solutions of the four chemicals were also tested. An American Society for Testing and Materials type permeation cell, ethanol liquid collection and gas chromatography-flame ionization detection of samples taken from the collection medium every 10 min facilitated determination of breakthrough times (BTs), cumulative permeated masses and steady-state permeation rates (SSPRs). Experiments were 4 h long for the NRL and PVC gloves and 8 h for NP gloves. No chemicals tested broke through the NP gloves when exposed for 8 h. In the ethanol solution, PPD and OAP started breaking through the PVC gloves at 40 min. The SSPRs of PVC gloves were higher than those for NRL gloves in all challenge conditions for both single chemicals and mixtures. No tested chemicals in hydrogen peroxide solutions permeated the gloves during the 4-h tests. The chemical composition of the challenge solution was a main effecter of BTs and SSPRs for the NRL glove. For disposable PVC gloves, the main factors of BTs were molecular size [molar volume (MV)] and polarity (logK(ow)), and the primary factors of SSPRs were concentration, MV and logK(ow). In conclusion, disposable NRL gloves and disposable PVC gloves should not be used repeatedly for handling the hair dye products. Hydrogen peroxide did not accelerate chemical breakthrough. The compositions of the challenge solutions and physical and chemical properties (MV and logK(ow)) affected permeation behaviors for different gloves.
Brackenbush, Larry W.; Hoenes, Glenn R.
1981-01-01
According to the present invention, a shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user withdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.
Radiation prevulcanized natural rubber latex: Cytotoxicity and safety evaluation on animal
NASA Astrophysics Data System (ADS)
Keong, C. C.; Zin, W. M. Wan; Ibrahim, P.; Ibrahim, S.
2010-05-01
Radiation prevulcanized natural rubber latex (RVNRL) was claimed to be more user friendly than natural rubber latex prevulcanized by sulphur curing system. The absence of Type IV allergy inducing chemicals in RVNRL make it a suitable material for manufacturing of many kinds of latex products, especially those come into direct contact with users. This paper reveals and discusses the findings of cytotoxicity test and safety evaluation on animal for RVNRL. The test was done on RVNRL films prepared by coagulant dipping method and RVNRL dipped products produced by latex dipped product manufacturers. Cytotocixity test was carried out on mammalian cell culture American Type Culture Collection CCL 81, Vero. Results indicated that no cytotoxic effect from RVNRL films and products was found on the cell culture. Two animal studies, namely dermal sensitization study and primary skin irritation study, were done on gloves made from RVNRL. Albino white guinea pigs were used as test subjects in dermal sensitization study and results showed no sensitization induced by the application of test material in the guinea pigs. Primary skin irritation study was done on New Zealand white rabbits and results showed that the product tested was not corrosive and was not a primary irritant
de Groot, Hans; Patiwael, Jiska A; de Jong, Nicolette W; Burdorf, Alex; van Wijk, Roy Gerth
2013-01-01
To compare the prevalence of sensitization and allergy to natural rubber latex amongst Erasmus Medical Centre (MC) operating theatre employees before and 10 years after the introduction of powder-free latex gloves. Descriptive study. Employees working permanently in the operating theatre were evaluated in 1998 (n = 163) and in 2009 (n = 178) for sensitization and allergies to natural latex by means of questionnaires, serological analyses and skin testing. The prevalence of sensitization and allergies within these 2 groups was then established and compared. The two groups were comparable in terms of gender, smoking habits, job classification, work-related symptoms and the number of individuals who had atopy. In 2009, the prevalence of sensitization to latex was statistically significantly lower than in 1998 (4.5 vs. 14.1%). Allergy to latex was also established a statistically significantly fewer number of times in 2009 than in 1998 (2.8 vs. 9.8%). This same trend could be observed in the subgroup that participated both years (n = 49). Individuals with an atopic constitution had a statistically significant higher risk of developing hypersensitivity to natural latex; the risk of developing an allergy to latex was also higher, but not significantly. After the study in 1998, the introduction of sterile, powder-free latex gloves very likely led to a decline in the prevalence of sensitization and allergy to natural latex in 2009.
Brown, Robert H; Taenkhum, Kanika; Buckley, Timothy J; Hamilton, Robert G
2004-08-01
Proactive medical institutions implement latex allergen avoidance to protect workers and patients with latex allergy and to prevent latex sensitization in these groups by creating latex-safe environments that include replacement of natural rubber latex examination and surgical gloves, especially those that are powdered, with synthetic alternatives. We have hypothesized that an apparent decreasing trend in new latex allergy cases in hospitals using only synthetic examination gloves but the occasional powdered latex surgical glove might result from constitutive differences in allergen content (particle size distribution and quantity) between powdered surgical gloves and examination gloves. Because aerodynamic particle size determines where inhaled airborne allergen deposits in the airway, the aim of this study was to investigate the differential particle size distribution of latex allergen released from powdered latex examination and surgical gloves. Powdered and nonpowdered latex examination and surgical gloves were processed to create an aerosol in a glove box equipped with air sampling equipment capable of total particle number and mass measurements. Air particulate generated in the glove box was collected on impactors with less than 2.5-microm, 2.5- to 10-microm, and greater than 10-microm particle size limits (4 L/min for 4 hours). All filters were extracted, and latex allergen was quantified by using a latex-CAP inhibition assay with a human IgE anti-latex serum pool. Latex aeroallergen on powdered sterile surgical gloves resided primarily on particles greater than 10 microm in size (P <.006). In contrast, powdered examination gloves released the highest total latex aeroallergen content, with 68% of the particles sized in the respirable 2.5- to 10-microm range and carrying 56% of the airborne latex allergen. Significantly lower quantities and larger sizes of latex allergen-containing particles released from surgical gloves provides one potential explanation as to why an apparent decrease in new cases of latex allergy can occur in hospitals that successfully replace latex examination gloves with synthetic gloves but continue occasional use of powdered surgical gloves.
NASA Technical Reports Server (NTRS)
Wingard, Doug
2009-01-01
The Advanced Crew Escape Suit (ACES) is a pressurized suit normally worn by astronauts during launch and landing phases of Space Shuttle operations. In 2008, a large tear (0.5 -1 in. long, between the pinky and ring finger) in the ACES left-hand glove made of neoprene latex rubber was found during training for Shuttle flight STS-124. An investigation to help determine the cause(s) of the glove tear was headed by the NASA Johnson Space Center (JSC) in Houston, Texas. Efforts at JSC to reproduce the actual glove tear pattern by cutting/tearing or rupturing were unsuccessful. Chemical and material property data from JSC such as GC-MS, FTIR, DSC and TGA mostly showed little differences between samples from the torn and control gloves. One possible cause for the glove tear could be a wedding ring/band worn by a male astronaut. Even with a smooth edge, such a ring could scratch the material and initiate the tear observed in the left-hand glove. A decision was later made by JSC to not allow the wearing of such a ring during training or actual flight. Another possible cause for the ACES glove tear is crystallinity induced by strain in the neoprene rubber over a long period of time and use. Neoprene is one several elastomeric materials known to be susceptible to crystallization, and such a process is accelerated with exposure of the material to cold temperatures plus strain. When the temperature is lowered below room temperature, researchers have shown that neoprene crystallization may be maintained at temperatures as high as 45-50 F, with a maximum crystallization rate near 20-25 F (1). A convenient conditioning temperature for inducing neoprene crystallization is a typical freezer that is held near 0 F. For work at the NASA Marshall Space Flight Center (MSFC), samples were cut from several areas/locations (pinky/ring finger crotch, index finger and palm) on each of two pairs of unstrained ACES gloves for DSC and DMA thermal analysis testing. The samples were conditioned in a freezer for various times up to about 14 days. Some rectangular conditioned samples were unstrained, while most were subjected to strains up to 250% with the aid of two slotted aluminum blocks and two aluminum clamps per sample. Trends were observed to correlate DSC data (heat of fusion) and DMA data (linear CTE and stress for iso-strain testing) with: (a) sample location on each glove; and (b) level of strain during conditioning. Control samples cut as is from each glove location were also tested by DSC and DMA.
Microgravity Science Glovebox - Glove
NASA Technical Reports Server (NTRS)
1997-01-01
This photo shows a rubber glove and its attachment ring for the Microgravity Science Glovebox (MSG) being developed by the European Space Agency (ESA) and NASA for use aboard the International Space Station (ISS). Scientists will use the MSG to carry out multidisciplinary studies in combustion science, fluid physics and materials science. The MSG is managed by NASA's Marshall Space Flight Center (MSFC). Photo Credit: NASA/MSFC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anastas, M.Y.; Caplan, P.E.; Froehlich, P.A.
An on-site visit was made to the Ortho Pharmaceutical Corporation (OPC), Raritan, New Jersey to evaluate methods of controlling exposure to hazardous materials during the manufacturing of medications. OPC produced oral-contraceptive tablets containing norethindrone (NOR), mestranol, and ethynylestradiol (EE). Ventilation was an important engineering control at this site. Other engineering controls included the isolation of work procedures and automation of work practices for weighing ingredients, granulation of substances, tableting, and packaging. Area samples were taken for air monitoring of steroid concentration levels in each manufacturing area. Access to the work areas was only through the locker rooms. Samples taken inmore » the locker rooms revealed no detectable contaminant levels. Workers performing high risk activities wore air supplied vinyl suits and disposable rubber gloves. The vinyl suits had overshoes attached. For moderate risk activities the workers wore a disposable suit, rubber gloves and shoe covers. Appropriate respirators were provided. Workers in low risk activities wore disposable rubber gloves and appropriate respirators. Sampling indicated that processing workers experienced breathing-zone levels outside their vinyl suits of 16.40 and 0.36 micrograms/cubic meter of NOR and EE, respectively.« less
NASA Astrophysics Data System (ADS)
Chankrachang, M.; Limphirat, W.; Yongyingsakthavorn, P.; Nontakaew, U.; Tohsan, A.
2017-09-01
A study of sulfidic linkages formed in natural rubber (NR) latex medical gloves by using X-ray Absorption Near Edge Structure (XANES) is presented in this paper. The NR latex compound was prepared by using prevulcanization method, that is, it was prevulcanized at room temperature for 24 hrs before utilization. After the 24 hrs of prevulcanization, the latex film samples were obtained by dipping process. The dipped films were subjected to vulcanize at 110°C for 5 to 25 min. It was observed that after the compound was prevulcanized for 24 hrs, polysulfidic linkages were mainly formed in the sample. It was however found that after curing at 110°C for 5-25 min, the polysulfidic linkages are tended to change into disulfide linkages. Especially, in the case of 25 minutes cured sample, disulfide linkages are found to be the main linkages. In term of tensile strength, it was observed that when cure time increased from 5 - 10 min, tensile strengths were also increased. But when the cure time of the film is 25 minutes, tensile strength was slightly dropped. The dropped of tensile strength when cure time is longer than 10 minutes can be ascribed to a degradation of polysulfidic and disulfidic linkages during curing. Therefore, by using XANES analysis, it was found to be very useful to understand the cure characteristic, thus it can be very helpful to optimize cure time and tensile properties of the product.
Association of contact urticaria and allergic contact dermatitis to rubber.
Fernadez, Ohalis Luanda; Canosa, Juliana Macedo; Lazzarini, Rosana; Duarte, Ida
2009-01-01
We present a case of a healthcare professional that developed type I and IV hypersensitivity reactions to rubber. During the clinical examination the patient showed eczematous dermatitis of the hands. The patch test was positive for thiuram group and an open test with a piece of glove was positive after 20 minutes of exposure. Allergen-specific IgE test (RAST) was relevant. Reactions to rubber allergens are frequent among healthcare professionals due to constant contact with this material.
29 CFR 1926.551 - Helicopters.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and mechanically. (e) Personal protective equipment. (1) Personal protective equipment for employees... the suspended load, or protective rubber gloves shall be worn by all ground personnel touching the...
29 CFR 1926.551 - Helicopters.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and mechanically. (e) Personal protective equipment. (1) Personal protective equipment for employees... the suspended load, or protective rubber gloves shall be worn by all ground personnel touching the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berardinelli, S.P.; Rusczek, R.A.; Mickelsen, R.L.
The National Institute for Occupational Safety and Health (NIOSH), in cooperation with Monsanto Chemical Company, conducted an on-site evaluation of chemical protective clothing at Monsanto's Nitro, West Virginia plant. The Monsanto plant manufactures additives for the rubber industry including antioxidants, pre-vulcanization inhibitors, accelerators, etc. This survey evaluated six raw materials that have a potential for skin absorption: aniline, cyclohexylamine, diisorpropylamine, tertiary butylamine, morpholine and carbon disulfide. Five generic glove materials were tested against these chemicals; nitrile, neoprene, polyvinylchloride, natural latex and natural rubber. The NIOSH chemical permeation portable test system was used to generate breakthrough time data. The results weremore » compared to permeation data reported in the literature that were obtained by using the ASTM F739-85 test method. The test data demonstrated that aniline has too low a vapor pressure for reliable analysis on the portable direct reading detectors used. The chemical permeation test system, however provided comparable, reliable permeation data for the other tested chemicals. Monsanto has used this data to better select chemical protective clothing for its intended use.« less
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... mitigate the effect. The precautionary paragraph must be immediately preceded by the appropriate signal... clothing. Wear goggles or face shield and rubber gloves when handling. Harmful or fatal if swallowed...
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... mitigate the effect. The precautionary paragraph must be immediately preceded by the appropriate signal... clothing. Wear goggles or face shield and rubber gloves when handling. Harmful or fatal if swallowed...
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... mitigate the effect. The precautionary paragraph must be immediately preceded by the appropriate signal... clothing. Wear goggles or face shield and rubber gloves when handling. Harmful or fatal if swallowed...
Latex allergy: a follow up study of 1040 healthcare workers
Filon, F Larese; Radman, G
2006-01-01
Background Natural rubber latex allergy can cause skin and respiratory symptoms The aim of this study was to evaluate the prevalence and incidence of latex related symptoms and sensitisation among a large group of healthcare workers in Trieste hospitals, followed for three years before and after the introduction of powder‐free gloves with low latex release. Methods In the years 1997–99 the authors evaluated 1040 healthcare workers exposed to latex allergen for latex related symptoms and sensitisation by means of a questionnaire, a medical examination, skin prick tests, and IgE specific antibody assay. The second evaluation was carried out in the years 2000–02, subsequent to the changeover to a powder‐free environment. Results Glove related symptoms were seen in 21.8% of the nurses (227), mostly consisting of mild dermatitis: 38 (3.6%) complaining of contact urticaria and 24 (2.3%) of asthma and/or rhinitis. These symptoms were significantly related to skin prick tests positive to latex (OR = 9.70; 95% CI 5.5 to 17) and to personal atopy (OR = 2.29; 95% CI 1.6 to 3.2). Follow up was completed in 960 subjects (92.3%): 19 new subjects (2.4%) complained of itching erythema when using gloves, but none was prick positive to latex. Symptoms significantly improved and in most cases disappeared (p<0.0001). Conclusions Simple measures such as the avoidance of unnecessary glove use, the use of non‐powdered latex gloves by all workers, and use of non‐latex gloves by sensitised subjects can stop the progression of latex symptoms and can avoid new cases of sensitisation. PMID:16421390
Glove-derived foreign proteins induce allergen-specific IgE in a mouse model.
Busch, Marion; Schröder, Claudia; Baron, Jens-Malte; Ott, Hagen; Bruckner, Thomas; Diepgen, Thomas L; Mahler, Vera
2008-04-01
Currently, most medical gloves are produced with a low content of natural rubber latex (NRL) protein. However, they may be substituted by proteins of foreign origin to maintain specific properties of the material. The aim of this study was to investigate the allergenicity and immunogenicity of unexpected proteins (i.e., soy and casein) compared with NRL proteins in a murine model in BALB/c mice. All respective allergen sources (extracts from three brands of NRL gloves, soy, and casein) were able to induce significant allergen-specific IgE and IgG(1) responses. On average, the highest IgE induction occurred after immunization with NRL, followed by soy and casein. Certain individuals from each treatment group exhibited levels of specific IgE as high as due to NRL. To analyze further specific IgE responses on a single allergen level, we established a microarray based on recombinant allergens for allergen-specific murine IgE detection. Besides specific IgE against rHev b 3, -6, -7, -8, and -11, specific IgE against kappa-casein could be detected in mice immunized with NRL glove extract, indicating a sensitization potential of the contained foreign protein. The substitution of genuine latex proteins by proteins of foreign origin may lead to a shift and de novo increase in sensitization to the finished products.
Satoh, Kanako; Nonaka, Ryouichi; Ohyama, Ken-ichi; Nagai, Fumiko; Ogata, Akio; Iida, Mitsuru
2008-03-01
Disposable gloves made of nitrile-butadiene rubber (NBR) are used for contact with foodstuffs rather than polyvinyl chloride gloves containing di(2-ethylhexyl)phthalate (DEHP), because endocrine-disruptive effects are suspected for phthalate diesters including DEHP. However, 4,4'-butylidenebis(6-t-butyl-m-cresol) (BBBC), 2,4-di-t-butylphenol, and 2,2,4-trimetyl-1,3-pentanediol diisobutyrate can be eluted from NBR gloves, and possibly also detected in food. In this study, we examined the endocrine-disrupting effects of these chemicals via androgen receptor (AR) and estrogen receptor (ER)-mediated pathways using stably transfected reporter gene cell lines expressing AR (AR-EcoScreen system) and ER (MVLN cells), respectively. We also examined the binding activities of these chemicals to AR and ER. The IC50 value of BBBC for antagonistic androgen was in the range of 10(-6)M. The strength of inhibition was about 5 times that of a known androgen antagonist, 1,1'-(2,2-dichloroethylidene)bis[4-chlorobenzene] (p,p'-DDE), and similar to that of bisphenol A. The IC50 value of BBBC for antagonistic estrogen was in the range of 10(-6)M. These results suggest that BBBC and its structural homologue, 4,4'-thiobis(6-t-butyl-m-cresol) are androgen and estrogen antagonists. It is therefore necessary to study these chemicals in vivo, and clarify their effect on the endocrine system.
CHARACTERIZATION OF GLOVEBOX GLOVES FOR THE SAVANNAH RIVER SITE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P.
A task was undertaken to characterize glovebox gloves that are currently used in the facilities at Savannah River Site (SRS) as well as some experimental and advanced compound gloves that have been proposed for use. Gloves from four manufacturers were tested for permeation in hydrogen and air, thermal stability, tensile properties, puncture resistance and dynamic mechanical response. The gloves were compared to each other within the type and also to the butyl rubber glove that is widely used at the SRS. The permeation testing demonstrated that the butyl compounds from three of the vendors behaved similarly and exhibited hydrogen permeabilitiesmore » of .52‐.84 x10{sup ‐7} cc H{sub 2}*cm / (cm{sup 2}*atm). The Viton glove performed at the lower edge of this bound, while the more advanced composite gloves exhibited permeabilities greater than a factor of two compared to butyl. Thermogravimetric analysis was used to determine the amount of material lost under slightly aggressive conditions. Glove losses are important since they can affect the life of glovebox stripper systems. During testing at 90, 120, and 150°C, the samples lost most of the mass in the initial 60 minutes of thermal exposure and as expected increasing the temperature increased the mass loss and shortened the time to achieve a steady state loss. The ranking from worst to best was Jung butyl‐Hypalon with 12.9 %, Piercan Hypalon with 11.4 %, and Jung butyl‐Viton with 5.2% mass loss all at approximately 140°C. The smallest mass losses were experienced by the Jung Viton and the Piercan polyurethane. Tensile properties were measured using a standard dog bone style test. The butyl rubber exhibited tensile strengths of 11‐15 MPa and elongations or 660‐843%. Gloves made from other compounds exhibited lower tensile strengths (5 MPa Viton) to much higher tensile strengths (49 MPa Urethane) with a comparable range of elongation. The puncture resistance of the gloves was measured in agreement with an ASTM standard. The Butyl gloves exhibited puncture resistance from 183 - 296 lbs/in for samples of 0.020 - 0.038 thick. Finally, the glass transition temperature and the elastic and viscoelastic properties as a function of temperature up to maximum use temperature were determined for each glove material using Dynamic Mechanical Analysis. The glass transition temperatures of the gloves were ‐60°C for butyl, ‐30°C for polyurethane, ‐ 16°C Hypalon, ‐16°C for Viton, and ‐24°C for polyurethane‐Hypalon. The glass transition was too complex for the butyl‐Hypalon and butyl‐Viton composite gloves to be characterized by a single glass transition temperature. All of the glass transition temperatures exceed the vendor projected use temperatures.« less
NASA Astrophysics Data System (ADS)
Ong, Hun Tiar; Julkapli, Nurhidayatullaili Muhd; Hamid, Sharifah Bee Abd; Boondamnoen, O.; Tai, Mun Foong
2015-12-01
Nitrile butadiene rubber (NBR) gloves are one of the most important personal protective equipments but they are possible to tear off and contaminate food or pharmaceutical and healthcare products during manufacturing and packaging process. High tendency of torn glove remaining in food or products due to white or light flesh-coloured glove is not easy to be detected by naked eyes. In this paper, iron oxide nanoparticles (IONs) selected as additive for NBR to improve its detectability by mean of magnetic properties. IONs synthesized via precipitation method and compounded with NBR latex before casting on petri dish. The properties of IONs were investigated by X-ray Diffractometry (XRD), Transmission Electron Microscope (TEM), Raman Spectroscopy and Vibrating Sample Magnetometer (VSM). Meanwhile NBR/IONs composites were studied by Thermogravimetry Analysis (TGA), Differential Scanning Calorimetry (DSC) and Vibrating Sample Magnetometer (VSM). It observed that, synthesized IONs shows of 25.28 nm crystallite with 25.86 nm semipherical (changed as) shape. Meanwhile, Magnetite and maghemite phase are found in range of 670 cm-1 and 700 cm-1 respectively, which it contributes magnetization saturation of 73.96 emu/g at 10,000 G by VSM. Thermal stability and magnetic properties were increased with incorporating IONs into NBR latex up to 20 phr. NBR/IONs 5 phr has the optimum thermal stability, lowest glass transition temperature (-14.83 °C) and acceptable range of magnetization saturation (3.83 emu/g at 10,000 G) to form NBR gloves with magnetic detectability.
Latex allergy: the perspective from the surgical suite.
Elliott, Beth A
2002-08-01
Latex allergy in the perioperative setting presents unique challenges to the health care system. Specific needs of the latex-sensitive patient are paramount, but consideration must also include the impact on health care workers vis-a-vis latex sensitization, environmental allergen control, and barrier protection against blood-borne pathogens. It has been well documented that the greatest source of latex aeroallergen in the surgical setting is latex gloves (both sterile and nonsterile). Levels of latex aeroallergen correlate strongly with use of high-allergen and powdered gloves, total number of gloves used, and the hours of activity in a given environment. A significant reduction in aeroallergen (>10-fold) can be achieved by switching to low-allergen gloves. Ready availability of and encouragement to use nonlatex alternatives when appropriate can further reduce exposure to latex allergens. Since 1998, the Food and Drug Administration has required all medical devices (or their packaging) that contain natural rubber latex to be so labeled. In addition, industry has responded with a host of latex-free products for use in patient care. This has helped eliminate a great deal of confusion about which products are safe for use with latex-sensitive individuals. However, despite significant efforts to educate the public and the health care industry regarding latex allergies, considerable misinformation persists. Provision of a completely latex-free environment in most surgical suites may be unrealistic, but every effort should be made to minimize the unnecessary exposure of patients and health care workers to latex allergens in this high-risk arena.
Yap, Hong Kai; Lim, Jeong Hoon; Nasrallah, Fatima; Yeow, Chen-Hua
2017-01-01
Various robotic exoskeletons have been proposed for hand function assistance during activities of daily living (ADL) of stroke survivors. However, traditional exoskeletons involve the use of complex rigid systems that impede the natural movement of joints, and thus reduce the wearability and cause discomfort to the user. The objective of this paper is to design and evaluate a soft robotic glove that is able to provide hand function assistance using fabric-reinforced soft pneumatic actuators. These actuators are made of silicone rubber which has an elastic modulus similar to human tissues. Thus, they are intrinsically soft and compliant. Upon air pressurization, they are able to support finger range of motion (ROM) and generate the desired actuation of the finger joints. In this work, the soft actuators were characterized in terms of their blocked tip force, normal and frictional grip force outputs. Combining the soft actuators and flexible textile materials, a soft robotic glove was developed for grasping assistance during ADL for stroke survivors. The glove was evaluated on five healthy participants for its assisted ROM and grip strength. Pilot test was performed in two stroke survivors to evaluate the efficacy of the glove in assisting functional grasping activities. Our results demonstrated that the actuators designed in this study could generate desired force output at a low air pressure. The glove had a high kinematic transparency and did not affect the active ROM of the finger joints when it was being worn by the participants. With the assistance of the glove, the participants were able to perform grasping actions with sufficient assisted ROM and grip strength, without any voluntary effort. Additionally, pilot test on stroke survivors demonstrated that the patient's grasping performance improved with the presence and assistance of the glove. Patient feedback questionnaires also showed high level of patient satisfaction and comfort. In conclusion, this paper has demonstrated the possibility of using soft wearable exoskeletons that are more wearable, lightweight, and suitable to be used on a daily basis for hand function assistance of stroke survivors during activities of daily living. PMID:29062267
Higgins, Claire L; Palmer, Amanda M; Cahill, Jennifer L; Nixon, Rosemary L
2016-10-01
Healthcare workers (HCWs) are at risk of developing occupational skin disease (OSD). To ascertain the causes of OSD in Australian HCWs in a tertiary referral clinic. A retrospective review was performed of patients assessed at the Occupational Dermatology Clinic in Melbourne from 1993 to 2014. Of 685 HCWs assessed in the clinic over a period of 22 years, 555 (81.0%) were diagnosed with OSD. The most common diagnosis was irritant contact dermatitis (ICD) (79.1%), followed by allergic contact dermatitis (ACD) (49.7%). Natural rubber latex allergy was also relatively frequent (13.0%). The major substances causing ACD were rubber glove chemicals (thiuram mix and tetraethylthiuram disulfide), preservatives (formaldehyde, formaldehyde releasers, and isothiazolinones), excipients in hand cleansers, which are hard-to-avoid weak allergens, and antiseptics. ACD caused by commercial hand cleansers occurred more frequently than ACD caused by alcohol-based hand rubs (ABHRs). Occupational ICD was mostly caused by water/wet work and hand cleansers, and environmental irritants such as heat and sweating. Understanding the causes of OSD in HCWs is important in order to develop strategies for prevention. We suggest that skin care advice should be incorporated into hand hygiene education. The use of ABHRs should be encouraged, weak allergens in skin cleansers should be substituted, and accelerator-free gloves should be recommended for HCWs with OSD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
29 CFR 1910.183 - Helicopters.
Code of Federal Regulations, 2011 CFR
2011-07-01
... mechanically. (e) Personal protective equipment. (1) Personal protective equipment shall be provided and the employer shall ensure its use by employees receiving the load. Personal protective equipment shall consist... device before ground personnel touch the suspended load, unless protective rubber gloves are being worn...
29 CFR 1910.183 - Helicopters.
Code of Federal Regulations, 2010 CFR
2010-07-01
... mechanically. (e) Personal protective equipment. (1) Personal protective equipment shall be provided and the employer shall ensure its use by employees receiving the load. Personal protective equipment shall consist... device before ground personnel touch the suspended load, unless protective rubber gloves are being worn...
... should— • handle soiled items carefully without agitating them, • wear rubber or disposable gloves while handling soiled items and wash your hands after, and wash the items with detergent at the maximum available cycle length then machine dry them. Visit CDC’s Norovirus Web site at ...
29 CFR 1910.137 - Electrical protective equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... produced by ozone on rubber under mechanical stress into a series of interlacing cracks); (C) An embedded... avoidance of handling sharp objects. (B) Any other class of glove may be used for similar work without...
29 CFR 1910.137 - Electrical protective equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... produced by ozone on rubber under mechanical stress into a series of interlacing cracks); (C) An embedded... avoidance of handling sharp objects. (B) Any other class of glove may be used for similar work without...
29 CFR 1910.137 - Electrical protective equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... produced by ozone on rubber under mechanical stress into a series of interlacing cracks); (C) An embedded... avoidance of handling sharp objects. (B) Any other class of glove may be used for similar work without...
29 CFR 1910.137 - Electrical protective equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... produced by ozone on rubber under mechanical stress into a series of interlacing cracks); (C) An embedded... avoidance of handling sharp objects. (B) Any other class of glove may be used for similar work without...
29 CFR 1910.137 - Electrical protective equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... produced by ozone on rubber under mechanical stress into a series of interlacing cracks); (C) An embedded... avoidance of handling sharp objects. (B) Any other class of glove may be used for similar work without...
Job strain among rubber-glove-factory workers in central Thailand.
Sein, Muang Muang; Howteerakul, Nopporn; Suwannapong, Nawarat; Jirachewee, Jirachai
2010-01-01
Job strain has become a major concern because of its potential impacts on worker well-being and performance. This cross-sectional study aimed to assess the prevalence of, and examine factors associated with, job strain among workers in a rubber-glove factory, in a central province of Thailand. A total of 200 workers aged 18-55 yr, who had worked at the factory for at least 6 months, completed the Job Content Questionnaire (JCQ) (Thai Version). Two of 5 scales in the JCQ were used to measure job strain, i.e.; job control and psychological job demand. The prevalence of job strain was 27.5%. Multiple logistic regression analysis indicated two variables significantly associated with job strain: low supervisor social support (adjusted OR=3.08; 95%CI: 1.38-6.91) and high job insecurity (adjusted OR=2.25; 95%CI: 1.04-4.88). Effective training for supervisors, to create good relationships among workers and supervisors, and ensuring steady and secure jobs for good employees, are necessary.
NASA Astrophysics Data System (ADS)
Dolez, Patricia; Vinches, Ludwig; Wilkinson, Kevin; Plamondon, Philippe; Vu-Khanh, Toan
2011-07-01
Nanoparticle manufacture and use are in full expansion. The associated risks of occupational exposure raise large concerns due to their potential toxicity. Even if they stand as a last resort in the traditional occupational Health & Safety (H&S) risk management strategy, personal protective equipment (PPE) against nanoparticles are an absolute need in the context of precautionary principle advocated by H&S organizations worldwide. However no standard test method is currently available for evaluating the efficiency of PPE against nanoparticles, in particular in the case of gloves. A project is thus underway to develop a test method for measuring nanoparticle penetration through protective gloves in conditions simulating glove-nanoparticle occupational interaction. The test setup includes an exposure and a sampling chamber separated by a circular glove sample. A system of cylinders is used to deform the sample while it is exposed to nanoparticles. The whole system is enclosed in a glove box to ensure the operator safety during assembly, dismounting and clean-up operations as well as during the tests. Appropriate nanoparticle detection techniques were also identified. Results are reported here for commercial 15nm TiO2 nanoparticles - powder and colloidal solutions in 1,2-propanediol, ethylene glycol and water - and four types of protective gloves: disposable nitrile and latex as well as unsupported neoprene and butyl rubber gloves. They show that mechanical deformations and contact with colloidal solution liquid carriers may affect glove materials. Preliminary results obtained with TiO2 powder indicate a possible penetration of nanoparticles through gloves following mechanical deformations.
30 CFR 77.606 - Energized trailing cables; handling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Energized trailing cables; handling. 77.606... COAL MINES Trailing Cables § 77.606 Energized trailing cables; handling. Energized medium- and high-voltage trailing cables shall be handled only by persons wearing protective rubber gloves (see § 77.606-1...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., approved by the Mine Safety and Health Administration (MSHA) and by the National Institute for Occupational Safety and Health (NIOSH), and have at a minimum a 30-minute air supply and full facepiece. (c... the crew are familiar with the operation of the equipment. (f) Boots and gloves shall be of rubber or...
Sorgini, Francesca; Massari, Luca; D’Abbraccio, Jessica; Petrovic, Petar B.; Carrozza, Maria Chiara; Newell, Fiona N.
2018-01-01
We present a tactile telepresence system for real-time transmission of information about object stiffness to the human fingertips. Experimental tests were performed across two laboratories (Italy and Ireland). In the Italian laboratory, a mechatronic sensing platform indented different rubber samples. Information about rubber stiffness was converted into on-off events using a neuronal spiking model and sent to a vibrotactile glove in the Irish laboratory. Participants discriminated the variation of the stiffness of stimuli according to a two-alternative forced choice protocol. Stiffness discrimination was based on the variation of the temporal pattern of spikes generated during the indentation of the rubber samples. The results suggest that vibrotactile stimulation can effectively simulate surface stiffness when using neuronal spiking models to trigger vibrations in the haptic interface. Specifically, fractional variations of stiffness down to 0.67 were significantly discriminated with the developed neuromorphic haptic interface. This is a performance comparable, though slightly worse, to the threshold obtained in a benchmark experiment evaluating the same set of stimuli naturally with the own hand. Our paper presents a bioinspired method for delivering sensory feedback about object properties to human skin based on contingency–mimetic neuronal models, and can be useful for the design of high performance haptic devices. PMID:29342076
Airfield Damage Recovery Techniques of 18th Engineer Brigade in Europe
1980-12-01
have to be observed. Comparable German regulations are published in "Verordnung uber gefAbrliche Arbeitsstoffe", issue May 1, 1976. Ŗ.1. Most important...rules: Rubber boots, acid-prove protective gloves, protective facial masks, water spray bottles for eyes 2.2. No smoking, no eating at jobside 3
Troubleshooting for the observed problems in processing latex concentrate from natural resource
NASA Astrophysics Data System (ADS)
Afreen, S.; Haque, K. R.; Huda, M. K.
2013-06-01
Natural latex has special importance in the rubber industry for manufacturing different types of goods like gloves, balloons, male contraceptive and similar thin walled articles. This natural latex is much more sensitive a liquid to handle since it can easily become contaminated and thereby coagulated which makes it unfavourable for centrifuge and getting concentrate from it. Some other related measures also are included in consideration during the processing of concentrate latex from the natural raw latex. The problems that are being faced in a concentrate latex processing plant can be categorized in different groups like, problems related to the latex property, mechanical problems, electrical problems, handling and storage problems, transformation problems, problems related to environmental issues, etc. Among them, the most common and vital problems frequently observed in a concentrate latex processing plant are discussed here with a view to finding the measures for solution which will help to maintain the latex property in any latex processing plant.
Occupational contact allergic dermatitis in dentistry.
Mikov, Ivan; Turkalj, Ivan; Jovanović, Marina
2011-06-01
Dental professionals may be at increased risk of developing occupational allergic diseases specially to methacrylates that can permeate protective disposable gloves. We presented a case of occupational allergic contact dermatitis in a 28-year-old dental technician. The patient had complained of itching and cracking of fingers for 6 months. The dermatitis improved over weekends. Skin erythema and scaling were present with primarily involvement of the fingertips. Patch testing with dental series gave positive vesicular reaction to methyl methacrylate. Follow-up after 6 months of allergen avoidance showed a complete regression of dermatitis. Methacrylates serve as bases for acrylic resins which are used in prosthetics. Methyl methacrylate as a small molecular acrylate can permeate thin protective disposable gloves. Using adequate personal protective equipment, like nitrile rubber gloves, is the most important preventive measure in this occupation. Health practitioners should recognize possible occupational hazards in dentistry and implement appropriate preventive measures to protect health of workers.
Studies on the preparation and uses of Co-60 gamma-ray irradiated natural latex
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kartowardoyo, S.; Sundardi, F.
1977-11-01
The properties are described of low-ammonia latex concentrates produced by gamma-ray irradiation (0.5 to 2.0 Mrad dose) in the presence of carbon tetrachloride or chloroform as sensitizer. Dipping trails with irradiated concentrates and irradiated field latex, for the preparation of condoms and medical gloves, gave products with high ultimate elongation, low modulus, and high permanent set. A change from straight dipping to coagulant dipping and a heat treatment after drying resulted in improved physical properties. A notable feature of products prepared from these materials is their purity, i.e., low content of rubber chemicals. An economic disadvantage, at the present time,more » is the high initial cost of the irradiation equipment.« less
Addition of Rubber to soil damages the functional diversity of soil.
Goswami, Madhurankhi; Bhattacharyya, Purnita; Tribedi, Prosun
2017-07-01
Rubber is a polymer of isoprene, consisting mainly of cis-1,4-polyisoprene units. The unmanageable production and its irresponsible disposal pose severe threats to environmental ecology. Therefore, the current study focuses extensively on the ill-effects of Rubber disposal on soil microbial functional diversity as it reflects the health of ecosystem by acting as a key component in ecosystem productivity. To investigate the effect of Rubber on soil microbial functional diversity, soil samples were collected from landfill sites and three different soil microcosms (Rubber treated, untreated, and sterile soil) were prepared. The soil enzymatic activity was determined by fluorescein diacetate hydrolysis followed by the determination of the microbial metabolic potential and functional diversity by average well color development and Shannon-Weaver index (H), respectively. BiOLOG ECO plates were used for determining the microbial functional diversity of the soil microcosms. Higher heterotrophic microbial count as well as higher soil microbial activity was observed in Rubber untreated soil than Rubber treated soil microcosm. The result indicated that the addition of Rubber to soil reduced soil heterotrophic microbial count and soil microbial activity considerably. Similarly, soil microbial metabolic potential as well as microbial functional diversity of soil had been decreased by the addition of Rubber gloves in it. Variation in soil microbial metabolic spectrum between Rubber treated and untreated microcosm was confirmed by multivariate analysis. Collectively, all the results demonstrated that the addition of Rubber to soil reduced the soil microbial functional diversity considerably. Therefore, it is necessary for the commission of serious steps regarding Rubber disposal and protection of the environment from serious environmental issues.
1997-03-11
This photo shows a rubber glove and its attachment ring for the Microgravity Science Glovebox (MSG) being developed by the European Space Agency (ESA) and NASA for use aboard the International Space Station (ISS). Scientists will use the MSG to carry out multidisciplinary studies in combustion science, fluid physics and materials science. The MSG is managed by NASA's Marshall Space Flight Center (MSFC). Photo Credit: NASA/MSFC
Hines, C J; Deddens, J A; Coble, J; Alavanja, M C R
2007-04-01
Fungicides are routinely applied to deciduous tree fruits for disease management. Seventy-four private orchard applicators enrolled in the Agricultural Health Study participated in the Orchard Fungicide Exposure Study in 2002-2003. During 144 days of observation, information was obtained on chemicals applied and applicator mixing, application, personal protective, and hygiene practices. At least half of the applicators had orchards with <100 trees. Air blast was the most frequent application method used (55%), followed by hand spray (44%). Rubber gloves were the most frequently worn protective equipment (68% mix; 59% apply), followed by respirators (45% mix; 49% apply), protective outerwear (36% mix; 37% apply), and rubber boots (35% mix; 36% apply). Eye protection was worn while mixing and applying on only 35% and 41% of the days, respectively. Bivariate analyses were performed using repeated logistic or repeated linear regression. Mean duration of mixing, pounds of captan applied, total acres sprayed, and number of tank mixes sprayed were greater for air blast than for hand spray (p < 0.05). Spraying from a tractor/vehicle without an enclosed cab was associated with wearing some type of coverall (p < 0.05). Applicators often did not wash their hands after mixing (77%), a finding not explained by glove use. Glove use during mixing was associated with younger age, while wearing long-sleeve shirts was associated with older age (p < 0.05 each). Self-reported unusually high fungicide exposures were more likely on days applicators performed repairs (p < 0.05). These data will be useful for evaluating fungicide exposure determinants among orchard applicators.
Mazur, Marcus D; Gurgel, Richard; MacDonald, Joel D
2018-01-01
Dissection of cerebellopontine angle (CPA) tumors that abut or adhere to the brainstem or cranial nerves can be a challenging surgical endeavor. We describe the use of semitranslucent latex rubber pledgets in the tumor-brain interface as a method to improve visualization and protection of vital tissue during microsurgical dissection of CPA masses. The rubber pledgets are fashioned by cutting circular discs out of the cuff portion of talc-free, partially opaque latex gloves. These pledgets provide a semitranslucent, nonadherent membrane that can be placed between vital neural tissues and a tumor capsule to minimize trauma during dissection. The semitranslucent latex enables visualization of the underlying anatomical structures while also providing a protective surface onto which a suction device can be rested to facilitate clearance of the surgical field. A 56-yr-old woman with left ear tinnitus presented with a 3-cm CPA meningioma. During microsurgical dissection, rubber pledgets were used to preserve the interface between the brain stem, cranial nerves, and tumor capsule. The use of the rubber pledgets appeared to secure the interface between to tumor and the brain while at the same time protecting the cranial nerves, brainstem, and cerebellum. Semitranslucent rubber pledgets may facilitate microsurgical dissection of CPA tumors. Copyright © 2017 by the Congress of Neurological Surgeons
Military Standardization Handbook: Aircraft Refueling Handbook
1992-10-20
explosive serious deterioration of rany rubber materials. It is as AVGAS. All aviation fuels must be handled therefore extremely important that only...additives are advised dissolved water a fuel will hold in parts per million to follow all instructions, wear gloves and aprons. (ppmt is approximately...FSII prevents the growth of contain one of these additives may cause abnormal Sfunguses and other microorganisrns which can wear or malfunctions or
VIEW OF JOHN ELDER OF JEANNETTE BADGE NO. 66. BREAKER ...
VIEW OF JOHN ELDER OF JEANNETTE BADGE NO. 66. BREAKER FOR GENERAL GLASS COMPANY. TAKEN ON BREAKER FLOOR IN FRONT OF BUCK USED TO HOLD GLASS. WORK EQUIPMENT INCLUDES: HARD HAT, SAFETY GLASSES, PROTECTIVE SLEEVES, LEATHER APRON, GLOVES WITH RUBBER PADS ("METATARSALS") WITH OVER STEEL-TOED SHOES. - Chambers-McKee Window Glass Company, Furnace No. 2, Clay Avenue Extension, Jeannette, Westmoreland County, PA
Degradation of latex and of natural rubber by Streptomyces strain La 7.
Gallert, C
2000-10-01
Streptomyces strain La 7 was isolated from the banquete of a city high way in Karlsruhe. According to partial 16S rRNA gene sequencing it was identical with Streptomyces albogriseolus and Streptomyces viridodiastaticus. DNA-DNA-similarity studies revealed 80.3-82.4% similarity between each of two of the three strains. Although phylogenetically closely related, Streptomyces strain La 7 differed from the two reference strains by morphological as well as physiological features and might represent a new species aside of S. albogriseolus and S. viridodiastaticus. The new Streptomyces strain La 7 was grown in a medium containing a latex emulsion or squares of natural rubber gloves as the only carbon source. On agar plates with a latex overlay agar, translucent halo formation around the colonies was observed. The unvulcanized latex was metabolized and the carbon from the isoprene units was apparently used for cell growth. In shake cultures with unlimited oxygen supply, during 60 days of incubation, 140 mg of the 175 mg totally emulgated latex were degraded exponentially. In sterile control flasks about 3% of the initial amount of latex could not be recovered after incubation on a shaker, presumably due to photochemical transformation. During static incubation of sterile medium, the latex formed a sticky layer at the surface of the medium and on the glass walls and recovery of the material was more difficult. Estimation of the protein content of cells from total nitrogen resulted in about 50% of the degraded latex being incorporated into cells, if a standard cell composition was assumed. Direct protein analysis according to Bradford (1976) gave much lower estimates, presumably due to a low content of aromatic amino acids. Stripes of natural rubber were degraded by Streptomyces strain La 7 during 70 days to an extent of about 30%. Scanning electron microscopy demonstrated, that hyphes of Streptomyces strain La 7 colonized and penetrated the latex surface with a concomitant deterioration of the latex material.
Prevalence of latex hypersensitivity among health care workers in Malaysia.
Shahnaz, M; Azizah, M R; Hasma, H; Mok, K L; Yip, E; Ganesapillai, T; Suraiya, H; Nasuruddin, B A
1999-03-01
Health care workers have been reported to constitute one of the few high-risk groups related to IgE-mediated hypersensitivity associated with the use of latex products. This paper describes the first ever study of prevalence carried out in Malaysia among these workers. One hundred and thirty health care personnel from Hospital Kuala Lumpur were skin tested. Extracts used were prepared from seven different brands of natural rubber latex gloves with varying levels of extractable protein (EPRRIM). Out of the 130 volunteers, 4 (3.1%) had positive skin test to latex with extracts with high levels of EPRRIM (> 0.7 mg/g). The prevalence among the Malaysian health care workers can be considered to be low in comparison to that of some consumer countries as the USA which reported a prevalence of as high as 16.9%.
Comparison of Piezoresistive Monofilament Polymer Sensors
Melnykowycz, Mark; Koll, Birgit; Scharf, Dagobert; Clemens, Frank
2014-01-01
The development of flexible polymer monofilament fiber strain sensors have many applications in both wearable computing (clothing, gloves, etc.) and robotics design (large deformation control). For example, a high-stretch monofilament sensor could be integrated into robotic arm design, easily stretching over joints or along curved surfaces. As a monofilament, the sensor can be woven into or integrated with textiles for position or physiological monitoring, computer interface control, etc. Commercially available conductive polymer monofilament sensors were tested alongside monofilaments produced from carbon black (CB) mixed with a thermo-plastic elastomer (TPE) and extruded in different diameters. It was found that signal strength, drift, and precision characteristics were better with a 0.3 mm diameter CB/TPE monofilament than thick (∼2 mm diameter) based on the same material or commercial monofilaments based on natural rubber or silicone elastomer (SE) matrices. PMID:24419161
2015-04-29
socks), white cotton glove liners , butyl rubber overboots, and self-contained breathing apparatus (SCBA) with air tank. Configuration 3: EOD suit...0073492 SCBA, CBRN, HP 60 Min Carbon DB, ZST, Case, VAS CON - CF Harness and Tank N/A 4240-20-A0F4879 Cylinder , Air Carbon HP 60 Minute - CF N/A 8120-20-007-3487 19
Dussoni, Simeone; Ceseracciu, Luca; Maggiali, Marco; Natale, Lorenzo; Metta, Giorgio; Athanassiou, Athanassia
2017-01-01
Abstract Stretchable capacitive devices are instrumental for new‐generation multifunctional haptic technologies particularly suited for soft robotics and electronic skin applications. A majority of elongating soft electronics still rely on silicone for building devices or sensors by multiple‐step replication. In this study, fabrication of a reliable elongating parallel‐plate capacitive touch sensor, using nitrile rubber gloves as templates, is demonstrated. Spray coating both sides of a rubber piece cut out of a glove with a conductive polymer suspension carrying dispersed carbon nanofibers (CnFs) or graphene nanoplatelets (GnPs) is sufficient for making electrodes with low sheet resistance values (≈10 Ω sq−1). The electrodes based on CnFs maintain their conductivity up to 100% elongation whereas the GnPs‐based ones form cracks before 60% elongation. However, both electrodes are reliable under elongation levels associated with human joints motility (≈20%). Strikingly, structural damages due to repeated elongation/recovery cycles could be healed through annealing. Haptic sensing characteristics of a stretchable capacitive device by wrapping it around the fingertip of a robotic hand (ICub) are demonstrated. Tactile forces as low as 0.03 N and as high as 5 N can be easily sensed by the device under elongation or over curvilinear surfaces. PMID:29619306
Cataldi, Pietro; Dussoni, Simeone; Ceseracciu, Luca; Maggiali, Marco; Natale, Lorenzo; Metta, Giorgio; Athanassiou, Athanassia; Bayer, Ilker S
2018-02-01
Stretchable capacitive devices are instrumental for new-generation multifunctional haptic technologies particularly suited for soft robotics and electronic skin applications. A majority of elongating soft electronics still rely on silicone for building devices or sensors by multiple-step replication. In this study, fabrication of a reliable elongating parallel-plate capacitive touch sensor, using nitrile rubber gloves as templates, is demonstrated. Spray coating both sides of a rubber piece cut out of a glove with a conductive polymer suspension carrying dispersed carbon nanofibers (CnFs) or graphene nanoplatelets (GnPs) is sufficient for making electrodes with low sheet resistance values (≈10 Ω sq -1 ). The electrodes based on CnFs maintain their conductivity up to 100% elongation whereas the GnPs-based ones form cracks before 60% elongation. However, both electrodes are reliable under elongation levels associated with human joints motility (≈20%). Strikingly, structural damages due to repeated elongation/recovery cycles could be healed through annealing. Haptic sensing characteristics of a stretchable capacitive device by wrapping it around the fingertip of a robotic hand (ICub) are demonstrated. Tactile forces as low as 0.03 N and as high as 5 N can be easily sensed by the device under elongation or over curvilinear surfaces.
Bensefa-Colas, L; Telle-Lamberton, M; Faye, S; Bourrain, J-L; Crépy, M-N; Lasfargues, G; Choudat, D; Momas, I
2015-12-01
Occupational contact urticaria (OCU) is an occupational contact dermatitis that can cause serious health consequences and disability at work. To describe OCU and its temporal trends by the main causal agents and activity sectors in a nationwide scheme in France. Using data from the French National Network for Occupational Disease Vigilance and Prevention (RNV3P), we described OCU reported during the period 2001-10 and analysed the temporal trends of OCU and OCU attributed to the most frequent agents over the study period. Trends analyses were supported by reporting odds ratios using a logistic regression model with reference to 2001, or with time as a continuous variable. During the study period, 251 cases of OCU were reported in RNV3P, half of which were due to natural rubber latex, in particular in the health and social work activity sector (HSW). The number of these cases declined significantly over the study period (19% per year), and particularly after 2006. Conversely, the other causes of OCU did not decrease. Using surveillance data from a French national network, this study has found that there was a significant decline in OCU due to natural rubber latex, particularly in the HSW, when powdered latex gloves were banned from French hospitals. Our results show the effectiveness of this preventive measure, and suggest that this practice should be extended to other sectors. © 2015 British Association of Dermatologists.
Computational Optimization of a Natural Laminar Flow Experimental Wing Glove
NASA Technical Reports Server (NTRS)
Hartshom, Fletcher
2012-01-01
Computational optimization of a natural laminar flow experimental wing glove that is mounted on a business jet is presented and discussed. The process of designing a laminar flow wing glove starts with creating a two-dimensional optimized airfoil and then lofting it into a three-dimensional wing glove section. The airfoil design process does not consider the three dimensional flow effects such as cross flow due wing sweep as well as engine and body interference. Therefore, once an initial glove geometry is created from the airfoil, the three dimensional wing glove has to be optimized to ensure that the desired extent of laminar flow is maintained over the entire glove. TRANAIR, a non-linear full potential solver with a coupled boundary layer code was used as the main tool in the design and optimization process of the three-dimensional glove shape. The optimization process uses the Class-Shape-Transformation method to perturb the geometry with geometric constraints that allow for a 2-in clearance from the main wing. The three-dimensional glove shape was optimized with the objective of having a spanwise uniform pressure distribution that matches the optimized two-dimensional pressure distribution as closely as possible. Results show that with the appropriate inputs, the optimizer is able to match the two dimensional pressure distributions practically across the entire span of the wing glove. This allows for the experiment to have a much higher probability of having a large extent of natural laminar flow in flight.
Operation Desert Shield Lessons Learned
1991-01-01
MRE, T and B rations) issued in Army Mess Halls. (2) Peelable fruits, i.e., oranges and bananas , apples, and pears after being peeled and washed...every day, they cannot get a good seal on their protective masks and are likely to become casualties in the event of a chemical attack. LESSON...liquid mustard agent is imminent. (2) Find clean areas to get relief from wearing rubber gloves and boots before softening of the hands and feet
Electrospinning of PVC with natural rubber
NASA Astrophysics Data System (ADS)
Othman, Muhammad Hariz; Mohamed, Mahathir; Abdullah, Ibrahim
2013-11-01
Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber's mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.
NASA Astrophysics Data System (ADS)
Ismail, R.; Ibrahim, A.; Rusop, M.; Adnan, A.
2018-05-01
The present article compares the mechanical properties of natural rubber (NR) and carbon nanotubes (CNTs) filled natural rubber composites. Four types of nanocomposite specimens are fabricated with different MWCNT loadings: 0 wt% (pure natural rubber), 1 wt%, 3 wt%, and 5 wt%. The specimens are tested for their mechanical properties. It is observed that the tensile strength, hardness and elongation break of CNTs filled rubber composites are remarkably higher than that of raw rubber indicating the inherent reinforcing potential of CNTs. Percentage of the elongation at break of rubber CNTs composites is lower than that of raw rubber.
Electrospinning of PVC with natural rubber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Othman, Muhammad Hariz; Abdullah, Ibrahim; Mohamed, Mahathir
Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber’s mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphologymore » and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.« less
Attebery, H. R.; Finegold, S. M.
1969-01-01
A double-closured method introduced for Hungate tubes eliminates clamps or special racks to hold the rubber stoppers in place while the tubes are being processed. The system prevents stoppers from being dislodged by gas-producing anaerobes and keeps the stoppers sterile so that the closed system of transfer can be conveniently utilized. Open and closed systems for handling a gas-producing anaerobe were compared. Ten tubes containing Clostridium perfringens were opened; the organism was detected in the air by use of an impingement collector. The gloved hand of the operator also revealed the test organism. A similar trial with culture material removed by the closed system (syringe transfer) resulted in no detectable contamination of the environment. Images PMID:4312921
Attebery, H R; Finegold, S M
1969-10-01
A double-closured method introduced for Hungate tubes eliminates clamps or special racks to hold the rubber stoppers in place while the tubes are being processed. The system prevents stoppers from being dislodged by gas-producing anaerobes and keeps the stoppers sterile so that the closed system of transfer can be conveniently utilized. Open and closed systems for handling a gas-producing anaerobe were compared. Ten tubes containing Clostridium perfringens were opened; the organism was detected in the air by use of an impingement collector. The gloved hand of the operator also revealed the test organism. A similar trial with culture material removed by the closed system (syringe transfer) resulted in no detectable contamination of the environment.
Chakrabarty, Romit; Qu, Yang; Ro, Dae-Kyun
2015-05-01
Natural rubber, cis-1,4-polyisoprene, is an important raw material in chemical industries, but its biosynthetic mechanism remains elusive. Natural rubber is known to be synthesized in rubber particles suspended in laticifer cells in the Brazilian rubber tree (Hevea brasiliensis). In the rubber tree, rubber elongation factor (REF) and its homolog, small rubber particle protein (SRPP), were found to be the most abundant proteins in rubber particles, and they have been implicated in natural rubber biosynthesis. As lettuce (Lactuca sativa) can synthesize natural rubber, we utilized this annual, transformable plant to examine in planta roles of the lettuce REF/SRPP homologs by RNA interference. Among eight lettuce REF/SRPP homologs identified, transcripts of two genes (LsSRPP4 and LsSRPP8) accounted for more than 90% of total transcripts of REF/SRPP homologs in lettuce latex. LsSRPP4 displays a typical primary protein sequence as other REF/SRPP, while LsSRPP8 is twice as long as LsSRPP4. These two major LsSRPP transcripts were individually and simultaneously silenced by RNA interference, and relative abundance, polymer molecular weight, and polydispersity of natural rubber were analyzed from the LsSRPP4- and LsSRPP8-silenced transgenic lettuce. Despite previous data suggesting the implications of REF/SRPP in natural rubber biosynthesis, qualitative and quantitative alterations of natural rubber could not be observed in transgenic lettuce lines. It is concluded that lettuce REF/SRPP homologs are not critically important proteins in natural rubber biosynthesis in lettuce. Copyright © 2014 Elsevier Ltd. All rights reserved.
Conductive fiber-based ultrasensitive textile pressure sensor for wearable electronics.
Lee, Jaehong; Kwon, Hyukho; Seo, Jungmok; Shin, Sera; Koo, Ja Hoon; Pang, Changhyun; Son, Seungbae; Kim, Jae Hyung; Jang, Yong Hoon; Kim, Dae Eun; Lee, Taeyoon
2015-04-17
A flexible and sensitive textile-based pressure sensor is developed using highly conductive fibers coated with dielectric rubber materials. The pressure sensor exhibits superior sensitivity, very fast response time, and high stability, compared with previous textile-based pressure sensors. By using a weaving method, the pressure sensor can be applied to make smart gloves and clothes that can control machines wirelessly as human-machine interfaces. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Latex allergy diagnosis: in vivo and in vitro standardization of a natural rubber latex extract.
Turjanmaa, K; Palosuo, T; Alenius, H; Leynadier, F; Autegarden, J E; André, C; Sicard, H; Hrabina, M; Tran, T X
1997-01-01
For the diagnosis of IgE-mediated (immediate) hypersensitivity to natural rubber latex (NRL), skin prick testing with extracts of latex gloves has been widely used, but such extracts are difficult to standardize. The present study aimed to produce on an industrial scale an NRL extract from freshly collected NRL and to evaluate, calibrate, and standardize the extract by both in vivo and in vitro testing. The source material, latex of the rubber tree, Hevea brasiliensis (clone RRIM 600), was frozen immediately after collection in Malaysia and shipped in dry ice to Stallergènes SA, France. Protein and allergen profiles were analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), immunoblotting, isoelectric focusing (IEF), crossed immunoelectrophoresis (CIE), and crossed radioimmunoelectrophoresis (CRIE). Allergen quantification was effected by RAST inhibition. The capacity of the preparation to elicit immediate hypersensitivity reactions in vivo was measured by skin prick testing in 46 latex-allergic patients and 76 nonallergic control subjects. SDS-PAGE and immunoblot profiles of the extract and an NRL standard (E8) provided by the US Food and Drug Administration were almost identical, disclosing several distinct IgE-binding proteins with apparent molecular weights of 14, 20, 27, 30, and 45 kDa, conforming to reported molecular weights of several significant NRL allergens. An arbitrary index of reactivity (IR) of 100 was assigned to the extract at 1:200 dilution (w/v), having a protein content of 22 micrograms/ml. Skin prick testing of latex-allergic patients and controls using the extract at 100 IR revealed 93% sensitivity, 100% specificity, 100% negative predictive value, and 96% positive predictive value. In conclusion, a skin prick test reagent for diagnosis of type I NRL allergy was successfully standardized. The reagent was demonstrated to contain most, if not all, of the currently known clinically significant NRL allergens, and it showed high sensitivity and specificity.
Roy, Ram Vinod; Das, Mithu; Banerjee, Rintu; Bhowmick, Anil K
2006-12-01
A comparative study on biodegradation of di-cumyl peroxide (DCP) crosslinked and uncrosslinked natural rubber by Pseudomonas sp. was carried out. Decrease in organic carbon content along with the changes in tensile strength of the treated rubber, both DCP crosslinked and uncrosslinked natural rubber, indicated rubber hydrocarbon utilization by the Pseudomonas sp. A decrease in 60.88% MPa and 41.66% MPa was observed after five month's old treated uncrosslinked natural rubber and DCP crosslinked rubber, respectively. Biodegradation was more pronounced in natural uncrosslinked rubber, which was further confirmed by the formation of aldehydic compounds with decrease in CH2 stretching frequencies.
Natural rubber (NR) biosynthesis: perspectives from polymer chemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barkakaty, Balaka
Natural rubber is an important strategic raw material for manufacturing a wide variety of industrial products. There are at least 2,500 different latex-producing plant species; however, only Hevea brasiliensis (the Brazilian rubber tree) is a commercial source. The chemical structure of natural rubber is cis-1,4-polyisoprene, but the exact structure of the head and end groups remains unknown. Since synthetic cis-1,4-polyisoprenes cannot match the superior properties of natural rubber, understanding the chemistry behind the biosynthetic process is key to finding a possible replacement. T his chapter summarizes our current understandings from the perspective of a polymer scientist by comparing synthetic polyisoprenesmore » to natural rubber. The chapter also highlights biomimetic polymerization, research towards a synthetic match of natural rubber and the role of natural rubber in health care.« less
Reinforcement effect of soy protein nanoparticles in amine-modified natural rubber latex
USDA-ARS?s Scientific Manuscript database
Mechanical properties of natural rubber reinforced with soy protein nanoparticles are useful for various rubber applications. However, the properties is further improved by improving interactions between soy protein and rubber. A novel method is used to modify particle surface of natural rubber late...
Pattern of occupational allergic dermatitis in the Dermatology Clinic, Hospital Kuala Lumpur.
Rohna, R; Ganesapillai, T; Salbiah, D; Zaiton, I
1999-03-01
A two years retrospective analysis of patients diagnosed as contact allergic dermatitis with positive patch test attending the Dermatology clinic was performed. Of the 346 patients with a positive patch test, 14% had occupational dermatitis. This condition affected mainly young and inexperienced workers. An inverse relationship was seen between age and prevalence of occupational allergic dermatitis. Allergic hand dermatitis was the commonest presentation in occupational allergic dermatitis. This was followed by dermatitis of the exposed skin (face, neck, hands and forearms). The common sensitising agents identified were rubber chemicals and nickel. The two main groups at risk were factory workers and medical personnel. The common allergens found in factory workers were epoxy resin, pewter, nickel and rubber chemicals. Exposure dermatitis occurred in patients working in the pewter industry. Two thirds of medical personnel with hand dermatitis were allergic to rubber gloves. One year follow up after patch testing showed that 19% of patients still suffered from chronic dermatitis. Dermatitis improved in 34% of patients. Forty-seven percent were cured and stopped attending the clinic after patch testing and adequate counselling.
NASA Astrophysics Data System (ADS)
Syamir Senin, Mohamad; Shahidan, Shahiron; Syazani Leman, Alif; Izzati Raihan Ramzi Hannan, Nurul
2016-11-01
Waste tires pose significant health and environmental concerns if not recycled or discarded properly. At the same time, natural sand is becoming scarcer and costlier due to its non-availability. Waste tires as fine aggregate can be an economical and sustainable alternative to the natural sand. Recent years, the interest on recycling waste tires into civil engineering applications by the researchers has increased. In this research, the chemical and physical properties of the tires rubber ash and the natural sand have been analysed. The densities of the rubber ash are lower than the natural sand. Rubber ash had finer particle size compared to the natural sand. Almost all chemical in the natural sand had in rubber ash with the additional sulphur trioxide and zinc oxide in the rubber ash, made the rubber ash better than natural sand. Rubber ash seems to be a suitable material to use in concrete as sand replacement.
NASA Astrophysics Data System (ADS)
Saputra, A. H.; Juneva, S.; Sari, T. I.; Cifriadi, A.
2018-04-01
Dimethyl ether can cause degradation of the rubber material seal in some applications. In order to use of natural rubber in industry, research about a blending of natural rubber (NR) and nitrile rubber (NBR) to produce rubber to meet the standard seal material application were conducted. This study will observe the degradation mechanisms that occur in the blending natural rubber and nitrile rubber (NR/NBR) by dimethyl ether. Nitrile rubber types used in this study is medium quality nitrile rubber with 33% of acrylonitrile content (NBR33). The observed parameters are percent change in mass, mechanical properties and surface morphology. This study is limited to see the effect of variation vulcanized blending ratio (NR/NBR33) against to swelling. The increase of nitrile rubber (NBR33) ratio of blending rubber vulcanized can reduce the tensile strength and elongation. The best elastomer variation was obtained after comparing with the standard feasibility material of seal is rubber vulcanized blending (NR/NBR33) with ratio 40:60 NR: NBR.
Constructing Gloved wings for aerodynamic studies
NASA Technical Reports Server (NTRS)
Bohn-Meyer, Marta R.
1988-01-01
Recently, two aircraft from the Dryden Flight Research Facility were used in the general study of natural laminar flow (NLF). The first, an F-14A aircraft on short-term loan from the Navy, was used to investigate transonic natural laminar flow. The second, an F-15A aircraft on long-term loan from the Air Force, was used to examine supersonic NLF. These tests were follow-on experiments to the NASA F-111 NLF experiment conducted in 1979. Both wings of the F-14A were gloved, in a two-phased experiment, with full-span(upper surface only) airfoil shapes constructed primarily of fiberglass, foam, and resin. A small section of the F-15A right wing was gloved in a similar manner. Each glove incorporated provisions for instrumentation to measure surface pressure distributions. The F-14A gloves also had provisions for instrumentation to measure boundary layer profiles, acoustic environments, and surface pitot pressures. Discussions of the techniques used to construct the gloves and to incorporate the required instrumentation are presented.
Sakaguchi, Hiroko; Wada, Koji; Kajioka, Jitsuo; Watanabe, Mayumi; Nakano, Ryuichi; Hirose, Tatsuko; Ohta, Hiroshi; Aizawa, Yoshiharu
2010-11-01
The maintenance of infectivity of influenza viruses on the surfaces of personal protective equipment and clothing is an important factor in terms of controlling viral cross-infection in the environment and preventing contact infection. The aim of this study was to determine if laboratory-grown influenza A (H1N1) virus maintained infectivity on the surfaces of personal protective equipment and clothing used in healthcare settings. Influenza A virus (0.5 mL) was deposited on the surface of a rubber glove, an N95 particulate respirator, a surgical mask made of non-woven fabric, a gown made of Dupont Tyvek, a coated wooden desk, and stainless steel. Each sample was left for 1, 8, and 24 h, and hemagglutination (HA) and 50% tissue culture infective dose (TCID(50))/mL were measured. The HA titer of this influenza A virus did not decrease in any of the materials tested even after 24 h. The infectivity of influenza A virus measured by TCID(50) was maintained for 8 h on the surface of all materials, with the exception of the rubber glove for which virus infectivity was maintained for 24 h. Our results indicate that the replacement/renewal of personal protective equipment and clothing by healthcare professionals in cases of exposure to secretions and droplets containing viruses spread by patients is an appropriate procedure to prevent cross-infection.
Preparation of vinyl acetate grafted natural rubber by irradiation method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Porntrairat, A.; Pattamaprom, C.
Improvement in properties of natural rubber could be done by several methods. In this research, gamma radiation technique, which is simple, accurate, easy to control and clean, was applied to enhance the properties of natural rubber (NR) in latex state. The purpose of this research is to study the appropriate condition for preparing grafted natural rubber latex by using irradiation method. Vinyl acetate monomers (VAc) were grafted onto natural rubber latex (NR-g-PVAc) at 0-10 kGys by gamma radiation from Cobalt-60 source at room temperature. Physical properties of grafted natural rubber such as chloroform number, swelling ratio and gel content weremore » measured. The VAc content of NR-g-PVAc was investigated by titration and visualized by FTIR spectroscopy. The FTIR spectra of NR-g-PVAc prepared at 0-10 kGys showed characteristic peaks of the vinyl acetate confirming that VAc could be grafted onto natural rubber molecular chains effectively under appropriate irradiation conditions. From the result, radiation grafting was found to be a useful technique for grafting of vinyl acetate onto natural rubber.« less
Medical devices manufactured from latex: European regulatory initiatives.
De Jong, W H; Geertsma, R E; Tinkler, J J B
2002-05-01
In Europe the marketing of medical devices manufactured from latex is regulated by directives describing the essential (safety) requirements that products have to fulfill to obtain marketing approval. This paper describes the general requirements for marketing medical devices in Europe and, more specifically, the requirements for products manufactured from natural rubber latex. The requirements for marketing medical devices can be fulfilled by using the relevant harmonized European standards. These standards are regularly under revision to incorporate the latest scientific developments. For certain devices, for example, latex medical (examination and surgical) gloves, specific standards have been published. Medical devices manufactured from latex pose a serious problem because of the risk of induction of allergy both against the latex proteins inherently present (type I or immediate type allergy) and against chemicals added during processing (type IV or delayed type hypersensitivity) present as residues in the latex products. So, besides requirements for product quality in terms of barrier properties, strength, and sterility, the main focus consists of the allergy-inducing properties of the latex products. Recent developments have reopened the discussion on the value of total protein versus allergen determination in latex medical gloves. However, as long as minimal levels needed for both sensitization and elicitation have not been established, a safe maximum level for leachable proteins/allergens in latex products cannot be determined. A European Commission guidance document on the latex allergy problem is currently being drafted by experts from Competent Authorities. Copyright 2002 Elsevier Science (USA).
Effects of tacky mat contamination on bond degradation for Chemlok/liner and NBR/liner bonds
NASA Technical Reports Server (NTRS)
Padilla, A. M.
1989-01-01
Tacky mats are placed by the rubber lay-up areas for the solid rocket motor segments. These mats dust off the shoes prior to entering the platform where the lay-up work is performed. The possibility exists that a tacky mat could be touched with gloved hands prior to handling the uncured nitride butadiene rubber (NBR). Tests were run to determine if NBR were accidentally touched would there be any degradation of the liner/NBR bond. The tacky mats were judged solely on the basis of bond degradation caused by either direct or indirect contamination. Test results all indicate that there was no notable NBR/Chemlok or liner/NBR bond degradation on samples that came into contact with the tacky mat material. Testing procedures are described. The tacky mat adhesive composition does not contain fluorocarbons or release agents that would affect bonding.
Shear modulus and damping ratio of natural rubber containing carbon nanotubes
NASA Astrophysics Data System (ADS)
Ismail, R.; Ibrahim, A.; Rusop, M.; Adnan, A.
2018-05-01
This paper presents the results of an investigation into the potential application of Natural rubber (NR) containing Carbon Nanotubes (CNTs) by measuring its shear modulus and damping ratio. Four different types of rubber specimens which fabricated with different MWCNT loadings: 0 wt% (pure natural rubber), 1 wt%, 3 wt%, and 5 wt%. It is observed that the shear modulus and damping ratio of CNTs filled rubber composites are remarkably higher than that of raw rubber indicating the inherent reinforcing potential of CNTs.
USDA-ARS?s Scientific Manuscript database
Blends of styrene-butadiene rubber and natural rubber that provide balanced properties were modified with acrylamide and reinforced with soy protein particles. The rubber composites show improved mechanical properties. Both modified rubber and composites showed a faster curing rate. The crosslinking...
Effect of urea deproteinization on catalytic hydrogenation of natural rubber latex
NASA Astrophysics Data System (ADS)
Cifriadi, A.; Chalid, M.; Puspitasari, S.
2017-07-01
Natural rubber is unsaturated biopolymer which has low resistance to heat, oxygen, and ozone. Chemical modification of natural rubber by catalytic hydrogenation can improve its oxidative property. In this study, the catalytic hydrogenation of natural rubber was investigated in latex phase after reduction of protein content with urea. Hydrogenation of deproteinized natural rubber latex was performed by using diimide which generated insitu from hydrazine hydrate/hydrogen peroxide and catalyst (boric acid, cupric sulfate and cupric acetate) at 70°C for 5 h. The hydrogenation system was stabilized with sodium dodecyl sulphate. The hydrogenation of deproteinized natural rubber (HDPNR) was confirmed by FTIR analysis. The result indicated that cupric sulphate was extremely active catalyst which was showed by the elimination of C=C transmittance bands at 1660 cm-1 on HDPNR spectra and highest degree of hydrogenation. Furthermore, urea deproteinization increased possibility of side reactions during catalytic hydrogenation as seen on the reduction of gel content compared to undeproteinized natural rubber.
Qu, Yang; Chakrabarty, Romit; Tran, Hue T.; Kwon, Eun-Joo G.; Kwon, Moonhyuk; Nguyen, Trinh-Don; Ro, Dae-Kyun
2015-01-01
Natural rubber (cis-1,4-polyisoprene) is an indispensable biopolymer used to manufacture diverse consumer products. Although a major source of natural rubber is the rubber tree (Hevea brasiliensis), lettuce (Lactuca sativa) is also known to synthesize natural rubber. Here, we report that an unusual cis-prenyltransferase-like 2 (CPTL2) that lacks the conserved motifs of conventional cis-prenyltransferase is required for natural rubber biosynthesis in lettuce. CPTL2, identified from the lettuce rubber particle proteome, displays homology to a human NogoB receptor and is predominantly expressed in latex. Multiple transgenic lettuces expressing CPTL2-RNAi constructs showed that a decrease of CPTL2 transcripts (3–15% CPTL2 expression relative to controls) coincided with the reduction of natural rubber as low as 5%. We also identified a conventional cis-prenyltransferase 3 (CPT3), exclusively expressed in latex. In subcellular localization studies using fluorescent proteins, cytosolic CPT3 was relocalized to endoplasmic reticulum by co-occurrence of CPTL2 in tobacco and yeast at the log phase. Furthermore, yeast two-hybrid data showed that CPTL2 and CPT3 interact. Yeast microsomes containing CPTL2/CPT3 showed enhanced synthesis of short cis-polyisoprenes, but natural rubber could not be synthesized in vitro. Intriguingly, a homologous pair CPTL1/CPT1, which displays ubiquitous expressions in lettuce, showed a potent dolichol biosynthetic activity in vitro. Taken together, our data suggest that CPTL2 is a scaffolding protein that tethers CPT3 on endoplasmic reticulum and is necessary for natural rubber biosynthesis in planta, but yeast-expressed CPTL2 and CPT3 alone could not synthesize high molecular weight natural rubber in vitro. PMID:25477521
Qu, Yang; Chakrabarty, Romit; Tran, Hue T; Kwon, Eun-Joo G; Kwon, Moonhyuk; Nguyen, Trinh-Don; Ro, Dae-Kyun
2015-01-23
Natural rubber (cis-1,4-polyisoprene) is an indispensable biopolymer used to manufacture diverse consumer products. Although a major source of natural rubber is the rubber tree (Hevea brasiliensis), lettuce (Lactuca sativa) is also known to synthesize natural rubber. Here, we report that an unusual cis-prenyltransferase-like 2 (CPTL2) that lacks the conserved motifs of conventional cis-prenyltransferase is required for natural rubber biosynthesis in lettuce. CPTL2, identified from the lettuce rubber particle proteome, displays homology to a human NogoB receptor and is predominantly expressed in latex. Multiple transgenic lettuces expressing CPTL2-RNAi constructs showed that a decrease of CPTL2 transcripts (3-15% CPTL2 expression relative to controls) coincided with the reduction of natural rubber as low as 5%. We also identified a conventional cis-prenyltransferase 3 (CPT3), exclusively expressed in latex. In subcellular localization studies using fluorescent proteins, cytosolic CPT3 was relocalized to endoplasmic reticulum by co-occurrence of CPTL2 in tobacco and yeast at the log phase. Furthermore, yeast two-hybrid data showed that CPTL2 and CPT3 interact. Yeast microsomes containing CPTL2/CPT3 showed enhanced synthesis of short cis-polyisoprenes, but natural rubber could not be synthesized in vitro. Intriguingly, a homologous pair CPTL1/CPT1, which displays ubiquitous expressions in lettuce, showed a potent dolichol biosynthetic activity in vitro. Taken together, our data suggest that CPTL2 is a scaffolding protein that tethers CPT3 on endoplasmic reticulum and is necessary for natural rubber biosynthesis in planta, but yeast-expressed CPTL2 and CPT3 alone could not synthesize high molecular weight natural rubber in vitro. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Advising parents on washing babies' clothes.
Scowen, P
1996-01-01
Detergents and other laundry products are generally effective and safe for all the family, but use carefully according to the maker's instructions and keep out of the reach of children. Rinse thoroughly to remove detergent residue from fabrics. If handwashing clothes, dissolve detergent before immersing hands. Wear rubber gloves if possible. Wash, rinse and dry hands thoroughly after contact with detergent. If a baby or parent has eczema, it may be necessary to try different products to see which one the client can tolerate. A non-perfumed, non-enzyme product may be found less irritating.
Chemical modifications of liquid natural rubber
NASA Astrophysics Data System (ADS)
Azhar, Nur Hanis Adila; Rasid, Hamizah Md; Yusoff, Siti Fairus M.
2016-11-01
Liquid natural rubber (LNR) was synthesized via photosentisized degradation of natural rubber (NR). LNR was modified into epoxidized liquid natural rubber (LENR) and hydroxylated liquid natural rubber (LNR-OH) using Na2WO4/CH3COOH/H2O2 catalytic system. Chemical structures of LNR and modified LNRs were characterized using Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) and 1H Nuclear Magnetic Resonance (NMR) spectroscopies. Integration of 1H NMR was used to calculate the epoxy content (%) of LENR. 1H NMR detected the formation of LNR-OH after prolonged heating and increased of catalyst in oxidation reaction.
Contact allergy to an epoxy reactive diluent: 1,4-butanediol diglycidyl ether.
Jolanki, R; Estlander, T; Kanerva, L
1987-02-01
3 female workers in a brush factory developed contact allergy from a 2-component epoxy glue containing epoxy resin (37% w/w), reactive diluents: i.e., 1,4-butanediol diglycidyl ether (BDDGE) 3%, glycidyl ethers of aliphatic alcohols (Epoxide 8) 0.03% and phenyl glycidyl ether (PGE) 0.01%; and inert fillers. All 3 patients were positive to the resin component of the glue and to BDDGE, indicating that BDDGE was the main allergen. 2 of the patients reacted to PGE, but none to the 3rd reactive diluent (Epoxide 8) in the glue. 2 of the patients did not react to epoxy resin, indicating that BDDGE may be an even stronger sensitizer in humans than epoxy resin, and that it does not cross-react with epoxy resins. Permeation studies revealed that BDDGE penetrates disposable PVC and rubber gloves in less than 30 min; thus, contaminated gloves should be replaced immediately. Reactive diluents should be included in patch test series if contact allergy to epoxy products is suspected.
Health-hazard-evaluation report MHETA 89-362-2027, Helen Mining Company, Homer City, Pennsylvania
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferguson, R.P.
1990-03-01
In response to a request from the United Mine Workers of America, an investigation was made of possible hazardous working conditions at the Helen Mining Company, Homer City, Pennsylvania. One of the tipple operators had complained of headaches, dizziness and skin rashes from working with a mixture of solvents used in the float/sink test operation. The solvents included perchloroethylene and dibromomethane. A week prior to receiving the request, the use of dibromomethane had been discontinued. Consequently, on the visit to the site, no traces of dibromomethane were found. After engineering controls were installed, only one of seven personal breathing zonemore » samples detected any perchloroethylene, and that sample was 0.12 parts per million, at the limit of detection. The author concludes that a hazard from perchloroethylene did not exist at the time of the evaluation. The author recommends replacing the rubber/cloth type glove being used with either a Teflon or Viton glove, and enclosing the work table.« less
[Incidence and increase in type I allergies to rubber gloves in dental medicine students].
Heese, A; Peters, K P; Stahl, J; Koch, H U; Hornstein, O P
1995-01-01
The prevalence of type I allergy against latex was investigated in dental students by questionnaire, prick tests and the determination of specific IgE antibodies. Positive prick tests against different latex fluids were found in 18 (8.7%) of 206 students, with clinical relevance in 11 cases. When the total number of students in each semester was taken into account an increase in the minimal prevalence of clinically relevant latex allergy from 2% in the second semester to 10.4% in the tenth semester was seen. A history of glove intolerance presenting as a wheal-and-flare reaction was associated with a type I allergy against latex in only 50% of the affected subjects. Atopic diseases and hand eczema of different causes proved to be risk factors in 16 and 5 of 18 students with latex allergy, respectively. A high-ammonia accelerator-free latex fluid proved to be a very reliable test medium compared to the less sensitive determination of specific IgE antibodies to latex.
USDA-ARS?s Scientific Manuscript database
Monitoring the growth of in vitro natural rubberwas accomplished by high resolution size exclusion chromatography, SEC.Washed rubber particles isolated from H. brasiliensis latex, containing the rubber transferase enzyme, were used to catalyze the polymerization of synthetic isopentenyl pyrophosphat...
Identification of natural rubber and characterization of rubber biosynthetic activity in fig tree.
Kang, H; Kang, M Y; Han, K H
2000-07-01
Natural rubber was extracted from the fig tree (Ficus carica) cultivated in Korea as part of a survey of rubber producing plants. Fourier transform infrared and (13)C nuclear magnetic resonance analysis of samples prepared by successive extraction with acetone and benzene confirmed that the benzene-soluble residues are natural rubber, cis-1,4-polyisoprene. The rubber content in the latex of fig tree was about 4%, whereas the rubber content in the bark, leaf, and fruit was 0.3%, 0.1%, and 0.1%, respectively. Gel-permeation chromatography revealed that the molecular size of the natural rubber from fig tree is about 190 kD. Similar to rubber tree (Hevea brasiliensis) and guayule (Parthenium argentatum Gray), rubber biosynthesis in fig tree is tightly associated with rubber particles. The rubber transferase in rubber particles exhibited a higher affinity for farnesyl pyrophosphate than for isopentenyl pyrophosphate, with apparent K(m) values of 2.8 and 228 microM, respectively. Examination of latex serum from fig tree by sodium dodecyl sulfate-polyacrylamide gel electrophoresis revealed major proteins of 25 and 48 kD in size, and several proteins with molecular mass below 20 and above 100 kD. Partial N-terminal amino acid sequencing and immunochemical analyses revealed that the 25- and 48-kD proteins were novel and not related to any other suggested rubber transferases. The effect of EDTA and Mg(2+) ion on in vitro rubber biosynthesis in fig tree and rubber tree suggested that divalent metal ion present in the latex serum is an important factor in determining the different rubber biosynthetic activities in fig tree and rubber tree.
Identification of Natural Rubber and Characterization of Rubber Biosynthetic Activity in Fig Tree1
Kang, Hunseung; Kang, Min Young; Han, Kyung-Hwan
2000-01-01
Natural rubber was extracted from the fig tree (Ficus carica) cultivated in Korea as part of a survey of rubber producing plants. Fourier transform infrared and 13C nuclear magnetic resonance analysis of samples prepared by successive extraction with acetone and benzene confirmed that the benzene-soluble residues are natural rubber, cis-1,4-polyisoprene. The rubber content in the latex of fig tree was about 4%, whereas the rubber content in the bark, leaf, and fruit was 0.3%, 0.1%, and 0.1%, respectively. Gel-permeation chromatography revealed that the molecular size of the natural rubber from fig tree is about 190 kD. Similar to rubber tree (Hevea brasiliensis) and guayule (Parthenium argentatum Gray), rubber biosynthesis in fig tree is tightly associated with rubber particles. The rubber transferase in rubber particles exhibited a higher affinity for farnesyl pyrophosphate than for isopentenyl pyrophosphate, with apparent Km values of 2.8 and 228 μm, respectively. Examination of latex serum from fig tree by sodium dodecyl sulfate-polyacrylamide gel electrophoresis revealed major proteins of 25 and 48 kD in size, and several proteins with molecular mass below 20 and above 100 kD. Partial N-terminal amino acid sequencing and immunochemical analyses revealed that the 25- and 48-kD proteins were novel and not related to any other suggested rubber transferases. The effect of EDTA and Mg2+ ion on in vitro rubber biosynthesis in fig tree and rubber tree suggested that divalent metal ion present in the latex serum is an important factor in determining the different rubber biosynthetic activities in fig tree and rubber tree. PMID:10889262
NASA Astrophysics Data System (ADS)
Harahap, H.; Ridha, M.; Halimatuddahliana; Taslim; Iriany
2018-02-01
This study about the resistance of natural rubber latex films using nanocrystals cellulose filler from corn cob waste by aging treatment. Corn cob used as organic filler composed of cellulose, hemicellulose, and lignin. Each component has a potential for reuse, such as cellulose. Cellulose from corn cob has potential application as a filler prepared by hydrolysis process using a strong acid. The producing of natural rubber latex films through coagulant dowsing process. This research started with the pre-vulcanization process of natural rubber latex at 70 °C and followed by process of vulcanization at 110 °C for 20 minutes. Natural rubber latex films that have been produced continued with the aging treatment at 70 °C for 168 hours. The mechanical properties of natural rubber latex films after aging treatment are the tensile strength, elongation at break, M100 and M300 have performed.
USDA-ARS?s Scientific Manuscript database
Natural rubber biosynthesis occurs in laticifers of Ficus elastica and Hevea brasiliensis, and in parenchyma cells of Parthenium argentatum. Natural rubber is synthesized by rubber transferase using allylic pyrophosphates as initiators, isopentenyl pyrophosphate as monomeric substrate and magnesium ...
Salomez, M; Subileau, M; Intapun, J; Bonfils, F; Sainte-Beuve, J; Vaysse, L; Dubreucq, E
2014-10-01
Natural rubber, produced by coagulation of the latex from the tree Hevea brasiliensis, is an important biopolymer used in many applications for its outstanding properties. Besides polyisoprene, latex is rich in many nonisoprene components such as carbohydrates, proteins and lipids and thereby constitutes a favourable medium for the development of micro-organisms. The fresh rubber coagula obtained by latex coagulation are not immediately processed, allowing the development of various microbial communities. The time period between tree tapping and coagula processing is called maturation, during which an evolution of the properties of the corresponding dry natural rubber occurs. This evolution is partly related to the activity of micro-organisms and to the modification of the biochemical composition. This review synthesizes the current knowledge on microbial populations in latex and natural rubber coagula of H. brasiliensis and the changes they induce on the biochemistry and technical properties of natural rubber during maturation. © 2014 The Society for Applied Microbiology.
Characterization of interaction between natural rubber and silica by FTIR
NASA Astrophysics Data System (ADS)
Jarnthong, Methakarn; Liao, Lusheng; Zhang, Fuquan; Wang, Yueqiong; Li, Puwang; Peng, Zheng; Malawet, Chutarat; Intharapat, Punyanich
2017-05-01
Blending of natural rubber (NR) and nanosilica (SiO2) was performed in latex state. The mechanical properties of NR/SiO2 nanocomposites at various filler contents were investigated. The interactions of unvulcanized natural rubber and nanosilica filler were characterized using Fourier Transform Infrared (FTIR)-Attenuated Total Reflectance (ATR) spectroscopy. The relationship between mechanical properties and rubber-filler interaction was discussed.
Effect of concentrated epoxidised natural rubber and silica masterbatch for tyre application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azira, A. A., E-mail: azira@lgm.gov.my; Kamal, M. M., E-mail: mazlina@lgm.gov.my; Verasamy, D., E-mail: devaraj@lgm.gov.my
The availability of concentrated epoxidised natural rubber (ENR-LC) has provided a better opportunity for using epoxidised natural rubber (ENR) with silica to reinforce natural rubber for tyre application. ENR-LC mixed directly with silica to rubber by high speed stirrer without using any coupling agent. Some rubber compounds were prepared by mixing a large amount of precipitated amorphous white silica with natural rubber. The silica was prepared in aqueous dispersion and the filler was perfectly dispersed in the ENR-LC. The performance of the composites was evaluated in this work for the viability of ENR-LC/Si in tyre compounding. Compounding was carried outmore » on a two roll mill, where the additives and curing agents was later mixed. Characterization of these composites was performed by Field Emission Scanning Electron Microscopy (FESEM) and Transmission Electron Microscopy (TEM) for dispersion as well as mechanical testing. C-ENR/Si showed efficient as primary reinforcing filler in ENR with regard to modulus and tensile strength, resulting on an increase in the stiffness of the rubbers compared to ENR latex. Overall improvement in the mechanical properties for the ENR-LC over the control crosslinked rubber sample was probably due to synergisms of silica reinforcement and crosslinking of the polymeric matrix phase.« less
Effect of concentrated epoxidised natural rubber and silica masterbatch for tyre application
NASA Astrophysics Data System (ADS)
Azira, A. A.; Verasamy, D.; Kamal, M. M.
2016-07-01
The availability of concentrated epoxidised natural rubber (ENR-LC) has provided a better opportunity for using epoxidised natural rubber (ENR) with silica to reinforce natural rubber for tyre application. ENR-LC mixed directly with silica to rubber by high speed stirrer without using any coupling agent. Some rubber compounds were prepared by mixing a large amount of precipitated amorphous white silica with natural rubber. The silica was prepared in aqueous dispersion and the filler was perfectly dispersed in the ENR-LC. The performance of the composites was evaluated in this work for the viability of ENR-LC/Si in tyre compounding. Compounding was carried out on a two roll mill, where the additives and curing agents was later mixed. Characterization of these composites was performed by Field Emission Scanning Electron Microscopy (FESEM) and Transmission Electron Microscopy (TEM) for dispersion as well as mechanical testing. C-ENR/Si showed efficient as primary reinforcing filler in ENR with regard to modulus and tensile strength, resulting on an increase in the stiffness of the rubbers compared to ENR latex. Overall improvement in the mechanical properties for the ENR-LC over the control crosslinked rubber sample was probably due to synergisms of silica reinforcement and crosslinking of the polymeric matrix phase.
Occupational allergic contact dermatitis from epoxy resin in a golf club repairman.
Isaksson, Marléne; Möller, Halvor; Pontén, Ann
2008-01-01
A golfer presented with facial and hand eczema. He had exacerbations of his hand eczema prior to golf tournaments. Being an authorized golf club repairman, he had been working with a two-part glue containing an epoxy resin (ER) based on diglycidyl ether of bisphenol A (DGEBA) and the hardener diethylenetriamine (DETA) for approximately 4 years before he developed any skin problems. He was patch-tested with the standard, which contains an ER based on DGEBA (DGEBA-R), epoxy (containing DETA), and rubber glove series and had positive reactions to DGEBA-R only. Other work materials (a latex glove, a golf glove made of leather, and part of the handle of his own golf club "as is" and in a methyl tert-butyl ether extract) were tested, with negative results. Allergic contact dermatitis from ER affects the skin by direct contact; the dermatitis is usually localized to the hands and forearms. If the face and eyelids are involved, the dermatitis may be due to exposure to airborne hardeners or reactive diluents, exposure to airborne dust from residual monomers, or ectopic allergic reactions. Our repairman had sandpapered an old glued surface, which may have led to possible airborne dust formation, thus explaining the facial eczema. Therefore, a worker with contact allergy to ER may continue working provided the skin is protected from contamination.
Zhou, Weiming; Li, Xiangyang; Lu, Jie; Huang, Ningdong; Chen, Liang; Qi, Zeming; Li, Liangbin; Liang, Haiyi
2014-01-01
As an indispensible material for modern society, natural rubber possesses peerless mechanical properties such as strength and toughness over its artificial analogues, which remains a mystery. Intensive experimental and theoretical investigations have revealed the self-enhancement of natural rubber due to strain-induced crystallization. However a rigorous model on the self-enhancement, elucidating natural rubber's extraordinary mechanical properties, is obscured by deficient understanding of the local hierarchical structure under strain. With spatially resolved synchrotron radiation micro-beam scanning X-ray diffraction we discover weak oscillation in distributions of strain-induced crystallinity around crack tip for stretched natural rubber film, demonstrating a soft-hard double network structure. The fracture energy enhancement factor obtained by utilizing the double network model indicates an enhancement of toughness by 3 orders. It's proposed that upon stretching spontaneously developed double network structures integrating hierarchy at multi length-scale in natural rubber play an essential role in its remarkable mechanical performance. PMID:25511479
Crack Velocities in Natural Rubber.
1982-05-01
vulcanized natural rubber (3). The surprisingly low value for natural rubber was attributed to highly anisotropic elastic behavior at high strains...Dr. R.L. Rabie Hercules Incorporated WX-2, MS-952 Alleghany Ballistic Lab Los Alamos National Lab. P.O. Box 210 P.O. Box 1663 Washington, D.C. 21502
2013-2014 Production of guayule natural rubber in Arizona, U.S.A.
USDA-ARS?s Scientific Manuscript database
Natural rubber is a unique biopolymer whose physical properties cannot be replicated in synthetic alternatives; therefore, it is required for production of tires (passenger, truck, and aircraft) and thousands of consumer and medical products. While demand for natural rubber is expected to increase ...
NASA Astrophysics Data System (ADS)
Raethong, P.; Boonkerd, K.
2017-07-01
Adhesion property of natural rubber (NR) and reclaimed natural rubber (RNR) based sealant with concrete was studied here. The effect of tackifier type and loading on the tensile properties of the rubber based sealant sandwished between two flat cements was evaluated. There are three different tackifiers including Coumarone-indene resin (CI), petro resin (PE) and gum rosin (GR). The result initially showed that at the 20 phr of tackifier both NR and RNR sealant mixed with CI consumed the highest force to separate the rubber based sealant from the concrete. This might be due to the highest compatiblility between CI and rubber. Regardless of the tackifier type, all NR based sealants showed the cohesive failure while all RNR based sealants only showed the adhesive failure. Moreover, the NR based sealant seemed to be stronger than the RNR based one. When considering the effect of CI loading on the adhesion, it was shown that for both NR and RNR based sealents, the highest stress was observed when the rubber based sealant loaded with the 20 phr of CI.
A study of amino acid modifiers in guayule natural rubber
USDA-ARS?s Scientific Manuscript database
Natural rubber from the Hevea tree is a critical agricultural material vital to United States industry, medicine, and defense, yet the country is dependent on imports to meet domestic needs. Guayule, a desert shrub indigenous to the US, is under development as an alternative source of natural rubber...
Thermal properties of hydrogenated liquid natural rubber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jamaluddin, Naharullah; Abdullah, Ibrahim; Yusoff, Siti Fairus M.
Natural rubber (NR) was modified to form liquid natural rubber (LNR) via photooxidative degradation. Hydrogenated liquid natural rubber (HLNR) was synthesized by using diimide as source of hydrogen which the diimide is produced by thermolysis of p-toluenesulfonyl hydrazide (TSH). The structure of HLNR was characterized by determining the changes of main peaks in Fourier Transform infrared and nuclear magnetic resonance spectra after hydrogenation. Thermogravimetric analysis showed that the HLNR had higher decomposition temperature compared to LNR and the decomposition temperature is directly proportional to the percentage of conversion.
Thermal properties of hydrogenated liquid natural rubber
NASA Astrophysics Data System (ADS)
Jamaluddin, Naharullah; Abdullah, Ibrahim; Yusoff, Siti Fairus M.
2015-09-01
Natural rubber (NR) was modified to form liquid natural rubber (LNR) via photooxidative degradation. Hydrogenated liquid natural rubber (HLNR) was synthesized by using diimide as source of hydrogen which the diimide is produced by thermolysis of p-toluenesulfonyl hydrazide (TSH). The structure of HLNR was characterized by determining the changes of main peaks in Fourier Transform infrared and nuclear magnetic resonance spectra after hydrogenation. Thermogravimetric analysis showed that the HLNR had higher decomposition temperature compared to LNR and the decomposition temperature is directly proportional to the percentage of conversion.
NASA Technical Reports Server (NTRS)
Yager, T. J.; Mccarty, J. L.
1977-01-01
A test program was conducted to evaluate friction performance and wear characteristics on wet runways of three 30 x 11.5-14.5, type, aircraft tires having two different tread patterns and natural rubber contents. All test tires had the standard three circumferential groove tread, but two had molded transverse grooves which extended from shoulder to shoulder. The tread rubber content of the two tires with transverse grooves differed in that one had a 100 percent natural rubber tread and the other had a rubber tread composition that was 30 percent synthetic and 70 percent natural. The third test tire had the conventional 100 percent natural rubber tread. Results indicate that the differences in tire tread design and rubber composition do not significantly affect braking and cornering friction capability on wet or dry surfaces. Braking performance of the tires decreases with increased speed, with increased yaw angle and, at higher speeds, with increased wetness of the surface.
The effect of carbon black loading and structure on tensile property of natural rubber composite
NASA Astrophysics Data System (ADS)
Savetlana, S.; Zulhendri; Sukmana, I.; Saputra, F. A.
2017-07-01
Natural rubber composite has been continuously developed due to its advantages such as a good combination of strength and damping property. Most of carbon black (CB)/Natural Rubber (NR) composite were used as material in tyre industry. The addition of CB in natural rubber is very important to enhance the strength of natural rubber. The particle loading and different structure of CB can affect the composite strength. The effects of CB particle loading of 20, 25 and 30 wt% and the effects of CB structures of N220, N330, N550 and N660 series on tensile property of composite were investigated. The result shows that the tensile strength and elastic modulus of natural rubber/CB composite was higher than pure natural rubber. From SEM observation the agglomeration of CB aggregate increases with particle loading. It leads to decrease of tensile strength of composite as more particle was added. High structure of CB particle i.e. N220 resulted in highest tensile stress. In fact, composite reinforced by N660 CB particle shown a comparable tensile strength and elastic modulus with N220 CB particle. SEM observation shows that agglomeration of CB aggregates of N330 and N550 results in lower stress of associate NR/CB composite.
Double gloving to reduce surgical cross-infection.
Tanner, J; Parkinson, H
2006-07-19
The invasive nature of surgery, with its increased exposure to blood, means that during surgery there is a high risk of transfer of pathogens. Pathogens can be transferred through contact between surgical patients and the surgical team, resulting in post-operative or blood borne infections in patients or blood borne infections in the surgical team. Both patients and the surgical team need to be protected from this risk. This risk can be reduced by implementing protective barriers such as wearing surgical gloves. Wearing two pairs of surgical gloves, triple gloves, glove liners or cloth outer gloves, as opposed to one pair, is considered to provide an additional barrier and further reduce the risk of contamination. The primary objective of this review was to determine if additional glove protection reduces the number of surgical site or blood borne infections in patients or the surgical team. The secondary objective was to determine if additional glove protection reduces the number of perforations to the innermost pair of surgical gloves. The innermost gloves (next to skin) compared with the outermost gloves are considered to be the last barrier between the patient and the surgical team. We searched the Cochrane Wounds Group Specialised Register (January 2006), and the Cochrane Central Register of Controlled Trials (CENTRAL)(The Cochrane Library Issue 4, 2005). We also contacted glove manufacturing companies and professional organisations. Randomised controlled trials involving: single gloving, double gloving, triple gloving, glove liners, knitted outer gloves, steel weave outer gloves and perforation indicator systems. Both authors independently assessed the relevance and quality of each trial. Data was extracted by one author and cross checked for accuracy by the second author. Two trials were found which addressed the primary outcome, namely, surgical site infections in patients. Both trials reported no infections. Thirty one randomised controlled trials measuring glove perforations were identified and included in the review. Fourteen trials of double gloving (wearing two pairs of surgical latex gloves) were pooled and showed that there were significantly more perforations to the single glove than the innermost of the double gloves (OR 4.10, 95% CI 3.30 to 5.09). Eight trials of indicator gloves (coloured latex gloves worn underneath latex gloves to more rapidly alert the team to perforations) showed that significantly fewer perforations were detected with single gloves compared with indicator gloves (OR 0.10, 95% CI 0.06 to 0.16) or with standard double glove compared with indicator gloves (OR 0.08, 95% CI 0.04 to 0.17). Two trials of glove liners (a glove knitted with cloth or polymers worn between two pairs of latex gloves)(OR 26.36, 95% CI 7.91 to 87.82), three trials of knitted gloves (knitted glove worn on top of latex surgical gloves)(OR 5.76, 95% CI 3.25 to 10.20) and one trial of triple gloving (three pairs of latex surgical gloves)(OR 69.41, 95% CI 3.89 to 1239.18) all compared with standard double gloves, showed there were significantly more perforations to the innermost glove of a standard double glove in all comparisons. There is no direct evidence that additional glove protection worn by the surgical team reduces surgical site infections in patients, however the review has insufficient power for this outcome. The addition of a second pair of surgical gloves significantly reduces perforations to innermost gloves. Triple gloving, knitted outer gloves and glove liners also significantly reduce perforations to the innermost glove. Perforation indicator systems results in significantly more innermost glove perforations being detected during surgery.
Edlich, Richard F; Mason, Shelley S; Swainston, Erin; Dahlstrom, Jill J; Gubler, K; Long, William B
2009-01-01
It has been well documented in the medical literature that powdered medical gloves can have serious consequences to patients and health-care workers. Adverse reactions to natural latex gloves, such as contact dermatitis and urticaria, occupational asthma, and anaphylaxis, have been documented as a significant cause of Workers' Compensation claims among health-care workers. While the cost of examination and surgical gloves is significant, this factor must be considered with the total cost of Workers' Compensation claims and possible litigation bestowed upon hospitals and glove manufacturing companies. In the United States, Canada, Belgium, and Germany, medical leaders have documented the dangers of powdered latex gloves and have implemented transition programs that are reducing Workers' Compensation claims filed by health-care workers. While attorneys view litigation against powdered glove manufacturers as the "next big tort", the authors of this article were not able to document all compensation costs to disabled workers because many settlements do not allow the claimant to disclose this information.
Cream concentrated latex for foam rubber products
NASA Astrophysics Data System (ADS)
Suksup, R.; Imkaew, C.; Smitthipong, W.
2017-12-01
Fresh natural latex (around 40% rubber and 60% water) can be transformed to concentrated natural latex (around 60% rubber and 40% water) in order to realise economical transportation and easier latex product’s preparation. The concentrated natural latex is an extremely valuable material. It can be applied for many types of products, for example, foam rubber as pillow and mattress, elastic band, etc. Industrially, the concentrated natural latex can be prepared by centrifugation which requires an enormous expensive machine. From the eco-friendly products point of view, most of rubber entrepreneurs in the world try to develop a green rubber product. So, the main objective of this study is to prepare the cream concentrated latex without any sophisticated machine. Thus, we work on a simple, cheap and green method that does not use any expensive machine but uses water-based chemical as sodium alginate to prepare the cream concentrated latex. The optimal amount of sodium alginate in the latex was studied. The main characteristics of the cream concentrated latex were tested by various technics, such as alkalinity, total solid content (TSC), dry rubber content (DRC), etc. We found that there are no significant differences of results between fresh natural latex and cream concentrated latex, except for the TSC and DRC. The TSC and DRC of cream latex are higher than those of fresh natural latex. Finally, we propose a model of natural rubber particle and sodium alginate to form the cream concentrated latex.
Forecasting Natural Rubber Price In Malaysia Using Arima
NASA Astrophysics Data System (ADS)
Zahari, Fatin Z.; Khalid, Kamil; Roslan, Rozaini; Sufahani, Suliadi; Mohamad, Mahathir; Saifullah Rusiman, Mohd; Ali, Maselan
2018-04-01
This paper contains introduction, materials and methods, results and discussions, conclusions and references. Based on the title mentioned, high volatility of the price of natural rubber nowadays will give the significant risk to the producers, traders, consumers, and others parties involved in the production of natural rubber. To help them in making decisions, forecasting is needed to predict the price of natural rubber. The main objective of the research is to forecast the upcoming price of natural rubber by using the reliable statistical method. The data are gathered from Malaysia Rubber Board which the data are from January 2000 until December 2015. In this research, average monthly price of Standard Malaysia Rubber 20 (SMR20) will be forecast by using Box-Jenkins approach. Time series plot is used to determine the pattern of the data. The data have trend pattern which indicates the data is non-stationary data and the data need to be transformed. By using the Box-Jenkins method, the best fit model for the time series data is ARIMA (1, 1, 0) which this model satisfy all the criteria needed. Hence, ARIMA (1, 1, 0) is the best fitted model and the model will be used to forecast the average monthly price of Standard Malaysia Rubber 20 (SMR20) for twelve months ahead.
NASA Astrophysics Data System (ADS)
Bao, Le Quoc; Phan, Vu Hoang Giang; Khuyen, Nguyen Quang
2018-04-01
Polymer nanocomposites that based on combination of nanomaterials (such as nanoparticles, nanotubes, nanorods, nanofibers, and nanosheets) and polymeric matrices are receiving great attention in research and application. However, separate and homogenous dispersion rather than aggregates of nanoparticles into matrices meet big difficulty due to large interaction between nanoparticles. The poor dispersion leads to low properties of nanocomposites. In this study, we find out the appropriate method to separately disperse cerium oxides (CeO2) nanoparticles into natural rubber, aiming to increase mechanical properties of natural rubber. The SEM images were used to evaluate the dispersion of nano CeO2 in natural rubber matrix. The mechanical properties of nanocomposites were measured after vulcanization to investigate effects of nano CeO2 amount on prepared composite. The findings exhibited that the addition of CeO2 by dispersion of nano CeO2 in water via ultrasonication before mixing with rubber latex, significantly increase modulus, tear and wear resistance of natural rubber.
Reinforcing Natural Rubber with Cellulose Nanofibrils Extracted from Bleached Eucalyptus Kraft Pulp
Chunmei Zhang; Tianliang Zhai; Ronald Sabo; Craig Clemons; Yi Dan; Lih-Sheng Turng
2014-01-01
Reinforced natural rubber (NR) nanocomposites were prepared by solution mixing, casting, and evaporation of pre-vulcanized natural rubber latex and an aqueous suspension of cellulose nanofibrils (CNFs) extracted from bleached eucalyptus kraft pulp. Scanning electron microscopy (SEM) images showed that there were no micro-scaled aggregates observed in the nanocomposites...
Schubert, S; Bauer, A; Molin, S; Skudlik, C; Geier, J
2017-03-01
Geriatric nurses (GN) have a high risk of occupational contact dermatitis (OCD), with chronic irritant contact dermatitis predominating. However, allergic contact dermatitis is an important issue as well. Little is known whether the relevant occupational allergen spectrum reported in the 1990s, including fragrances, preservatives, rubber chemicals and ingredients of surface disinfectants to be the most common sensitizers in GN, is still valid. To monitor the current allergen spectrum in GN with OCD and verify the validity of the patch test recommendations (baseline-, preservative-, ointment base-, rubber-, disinfectant, series and fragrances) in GN with suspected OCD given by the German Contact Dermatitis Research Group (DKG). Retrospective analysis of IVDK data (2005-2014) of 743 female GN with OCD, in comparison to 695 GN without OCD. GN with OCD reacted significantly more frequently to both fragrance mixes, hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC), thiuram mix, zinc diethyldithiocarbamate and mercaptobenzothiazole than GN without OCD. Reactions to MDBGN, methylchloroisothiazolinone/methylisothiazolinone and oil of turpentine occurred substantially, but not significantly more frequently among GN with OCD. The latter may be due to former use of a special alcoholic liniment in geriatric care. Among material from the patients' workplaces, tetrazepam was a frequent allergen, due to dust exposure from pill crushing. Furthermore, occupationally used protective gloves, body care products as well as surface disinfectants were often tested positively. The general allergen spectrum in GN with OCD is unchanged, so the DKG patch test recommendations are still valid. Prevention of occupational sensitization should focus on fragrance-free hygiene and body care products, usage of accelerator-free protective gloves and avoidance of drug dust exposure. © 2016 European Academy of Dermatology and Venereology.
Development of a prototype movement assistance system for extravehicular activity gloves
NASA Astrophysics Data System (ADS)
Hill, Tyler N.
Spacesuits utilized a rubberized layer of material to contain a pressurized atmosphere to facilitate respiration and maintain the physiologic functions of the astronaut residing within. However, the elasticity of the material makes it resistant to deformation increasing the amount of work required during movement. This becomes particularly fatiguing for the muscle groups controlling the motion of the hands and fingers. To mitigate this a robotic system was proposed and developed. The system built upon previous concepts and prototypes discovered through research efforts. It utilized electric motors to pull the index, ring, and middle fingers of the right hand closed, ideally overcoming the resistive force posed by the pressurized elastic material. The effect of the system was determined by comparing qualitative and quantitative data obtained during activities conducted with and without it within a glove box. It was found that the system was able to offload some of this elastic force though several characteristics of the design limited the full potential this device offered. None the less, the project was met with success and provides a solid platform for continued research and development.
Yikmis, Meral
2012-01-01
This review intends to provide an overview of historical and recent achievements in studies of microbial degradation of natural and synthetic rubber. The main scientific focus is on the key enzymes latex-clearing protein (Lcp) from the Gram-positive Streptomyces sp. strain K30 and rubber oxygenase A (RoxA) from the Gram-negative Xanthomonas sp. strain 35Y, which has been hitherto the only known rubber-degrading bacterium that does not belong to the actinomycetes. We also emphasize the importance of knowledge of biodegradation in industrial and environmental biotechnology for waste natural rubber disposal. PMID:22504822
Integrity of Disposable Nitrile Exam Gloves Exposed to Simulated Movement
Phalen, Robert N.; Wong, Weng Kee
2011-01-01
Every year, millions of health care, first responder, and industry workers are exposed to chemical and biological hazards. Disposable nitrile gloves are a common choice as both a chemical and physical barrier to these hazards, especially as an alternative to natural latex gloves. However, glove selection is complicated by the availability of several types or formulations of nitrile gloves, such as low-modulus, medical-grade, low-filler, and cleanroom products. This study evaluated the influence of simulated movement on the physical integrity (i.e., holes) of different nitrile exam glove brands and types. Thirty glove products were evaluated out-of-box and after exposure to simulated whole-glove movement for 2 hr. In lieu of the traditional 1-L water-leak test, a modified water-leak test, standardized to detect a 0.15 ± 0.05 mm hole in different regions of the glove, was developed. A specialized air inflation method simulated bidirectional stretching and whole-glove movement. A worst-case scenario with maximum stretching was evaluated. On average, movement did not have a significant effect on glove integrity (chi-square; p=0.068). The average effect was less than 1% between no movement (1.5%) and movement (2.1%) exposures. However, there was significant variability in glove integrity between different glove types (p ≤ 0.05). Cleanroom gloves, on average, had the highest percentage of leaks, and 50% failed the water-leak test. Low-modulus and medical-grade gloves had the lowest percentages of leaks, and no products failed the water-leak test. Variability in polymer formulation was suspected to account for the observed discrepancies, as well as the inability of the traditional 1-L water-leak test to detect holes in finger/thumb regions. Unexpectedly, greater than 80% of the glove defects were observed in the finger and thumb regions. It is recommended that existing water-leak tests be re-evaluated and standardized to account for product variability. PMID:21476169
Amino acid modifiers in guayule rubber compounds
USDA-ARS?s Scientific Manuscript database
Tire producers are increasingly interested in biobased materials, including rubber but also as compounding chemicals. An alternative natural rubber for tire use is produced by guayule, a woody desert shrub native to North America. Alternative compounding chemicals include naturally-occurring amino a...
Guayule resin detection and influence on guayule rubber
USDA-ARS?s Scientific Manuscript database
Guayule (Parthenium argentatum) is a natural rubber (cis-1,4-polyisoprene) producing crop, native to North America. Guayule also produces organic resins, complex mixtures of terpenes, triglycerides, guayulins, triterpenoids and other components. During natural rubber extraction, guayule resins can b...
NASA Astrophysics Data System (ADS)
Vinches, Ludwig
Manufactured titanium dioxide nanoparticles (nTiO2) enter into the formulation of several commercial products including cosmetics, paints, varnishes or food. An increasing number of people will be exposed to nanoparticles (NP), in particular, scientists during their research and workers in companies. As such, they are an emerging source of hazard. Indeed, an increasing number of studies are warning against their likely harmful effects on health. The International Agency for Research against Cancer has classified nTiO2 as being possibly carcinogenic to humans. Furthermore some studies have shown that the skin is not an impervious membrane to the NP and that NP penetration is possible when the skin is injured by abrasion, after repeated flexions or even intact. Therefore, dermal protection will be necessary in order to thoroughly protect NP users. Based upon the precautionary principle, gloves should be used as protection against chemicals. However, to the best of our knowledge, no study on their resistance towards NP has been conducted. In this study, the performance of protective gloves was evaluated with respect to nTiO2 solutions and powders, under conditions simulating occupational use. Mechanical deformations, simulating those produced by hand flexing, were applied to nitrile and butyl rubber and latex samples that were in contact with nTiO2 in water, in propylene glycol or in powder form. nTiO 2 penetration through the protective gloves was determined after deformations of the materials. Following these results, the physicochemical and mechanical phenomena that facilitate the penetration of nTiO2 were identified and studied. It was shown that mechanical deformations caused both damage to the sample surface but also a change in the degree of crystallinity of the glove material. Strain energy was also measured. It decreased significantly in presence and absence of nTiO2, indicating a weakening of the polymer chains. A qualitative study showed that repetitive deformations also lead to a decrease in the size of the agglomerates that were contained in the nTiO2 powder. Glove materials that were in contact with colloidal solutions produced a swelling phenomenon. Finally, measurements of the elongation of glove samples immersed in colloidal solutions were used to determine diffusion coefficients across the materials. The transport of the nanoparticles was driven by that of the carrier liquid (water or propylene glycol). Given the carrier solutions and nanoparticles could be transported through the gloves, exposure to skin could occur.
Nanthini, Jayaram; Chia, Kim-Hou; Thottathil, Gincy P; Taylor, Todd D; Kondo, Shinji; Najimudin, Nazalan; Baybayan, Primo; Singh, Siddharth; Sudesh, Kumar
2015-11-20
Streptomyces sp. strain CFMR 7, which naturally degrades rubber, was isolated from a rubber plantation. Whole genome sequencing and assembly resulted in 2 contigs with total genome size of 8.248 Mb. Two latex clearing protein (lcp) genes which are responsible for rubber degrading activities were identified. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rahman, R.; Nemmang, M. S.; Hazurina, Nor; Shahidan, S.; Khairul Tajuddin Jemain, Raden; Abdullah, M. E.; Hassan, M. F.
2017-11-01
The main issue related to this research was to examine the feasibility of natural rubber SMR 20 in the manufacturing of cement mortar for sub-base layer construction. Subbase layers have certain functions that need to be fulfilled in order to assure strong and adequate permeability of pavement performance. In a pavement structure, sub-base is below the base and serves as the foundation for the overall pavement structure, transmitting traffic loads to the sub-grade and providing drainage. Based on this research, the natural rubber, SMR 20 was with the percentages of 0%, 5%, 10% and 15% to mix with sand in the manufacture of the cement mortar. This research describes some of the properties and cost of the materials for the natural rubber and sand in cement mortar manufacturing by laboratory testing. Effects of the natural rubber replacement on mechanical properties of mortar were investigated by laboratory testing such as compressive strength test and density. This study obtained the 5% of natural rubber replaced in sand can achieved the strength of normal mortar after 7 days and 28 days. The strength of cement mortar depends on the density of cement mortar. According to the cost of both materials, sand shows the lower cost in material for the cement mortar manufacturing than the uses of natural rubber. Thus, the convectional cement mortar which used sand need lower cost than the modified rubber cement mortar and the most economical to apply in industrial. As conclusion, the percentage of 5% natural rubber in the cement mortar would have the same with normal cement mortar in terms of the strength. However, in terms of the cost of the construction, it will increase higher than cost of normal cement mortar production. So that, this modified cement mortar is not economical for the road sub-base construction.
Double gloving to reduce surgical cross-infection.
Tanner, J; Parkinson, H
2002-01-01
The invasive nature of surgery, with its increased exposure to blood, means that during surgery there is a high risk of transfer of pathogens. Pathogens can be transferred through contact between surgical patients and the surgical team, resulting in post-operative or blood borne infections in patients or blood borne infections in the surgical team. Both patients and the surgical team need to be protected from this risk. This risk can be reduced by implementing protective barriers such as wearing surgical gloves. Wearing two pairs of surgical gloves, as opposed to one pair, is considered to provide an additional barrier and further reduce the risk of contamination. The primary objective of this review was to determine if double gloving (wearing two pairs of gloves), rather than single gloving, reduces the number of post-operative or blood borne infections in surgical patients or blood borne infections in the surgical team. The secondary objective of this review was to determine if double gloving, rather than single gloving, reduces the number of perforations to the innermost pair of surgical gloves. The innermost gloves (next to skin) compared with the outermost gloves are considered to be the last barrier between the patient and the surgical team. The reviewers searched the Cochrane Wounds Group Specialised Trials Register, MEDLINE, CINAHL, EMBASE and the Cochrane Controlled Trials Register. Glove manufacturing companies and professional organisations were also contacted. Randomised controlled trials involving: single gloving, double gloving, glove liners or coloured puncture indicator systems. Both reviewers independently assessed the relevance and quality of each trial. Trials to be included were cross checked and authenticated by both reviewers. Data was extracted by one reviewer and cross checked for accuracy by the second reviewer. Two trials were found which addressed the primary outcome. A total of 18 randomised controlled trials which measured glove perforations were identified and included in the review. DOUBLE GLOVING (wearing two pairs of latex gloves). Nine trials compared single latex gloves versus double latex gloves. These found no difference in the number of perforations between the single latex gloves and the outermost pair of the double latex gloves, but the number of perforations to the double latex-innermost glove was significantly reduced when two pairs of latex gloves were worn. ORTHOPAEDIC GLOVES (thicker than standard latex gloves). One trial compared single latex orthopaedic gloves with double latex gloves. This showed there was no difference in the number of perforations to the innermost gloves when wearing double latex gloves compared with a single pair of latex orthopaedic gloves. INDICATOR GLOVES (coloured latex gloves worn underneath latex gloves). Three trials compared double latex gloves versus double latex indicator gloves. These trials showed similar numbers of perforations to both the innermost and the outermost gloves for both gloving groups. Perforations to the outermost gloves were detected more easily when double latex indicator gloves were worn. Wearing double latex indicator gloves did not increase the detection of perforations to the innermost gloves. GLOVE LINERS (an insert worn between two pairs of latex gloves). Two trials compared double latex gloves versus double latex gloves with liners. These trials showed a significant reduction in the number of perforations to the innermost glove when a glove liner was worn between two pairs of latex gloves. CLOTH GLOVES (cloth gloves worn on top of latex gloves). Two trials compared double latex gloves versus latex inner with cloth outer gloves. These trials showed that wearing a cloth outer glove significantly reduced the number of perforations to the innermost latex glove. STEEL WEAVE GLOVES (steel weave gloves worn on top of latex gloves). One trial compared double latex gloves versus latex inner with steel weave outer gloves. This trial showed no reduction in the number of perforations to the innermost glove when wearing a steel weave outer glove. Wearing two pairs of latex gloves significantly reduces the number of perforations to the innermost glove. This evidence comes from trials undertaken in 'low risk' surgical specialties, that is specialties which did not include orthopaedic joint surgery. Wearing two pairs of latex gloves does not cause the glove wearer to sustain more perforations to their outermost glove. Wearing double latex indicator gloves enables the glove wearer to detect perforations to the outermost glove more easily than when wearing double latex gloves. However wearing a double latex indicator system will not assist with the detection of perforations to the innermost glove, nor reduce the number of perforations to either the outermost or the innermost glove. Wearing a glove liner between two pairs of latex gloves to undertake joint replacement surgery significantly reduces the number of perforations to the innermost glove compared with double latex gloves only. Wearing cloth outer gloves to undertake joint replacement surgery significantly reduces the number of perforations to the innermost glove compared with wearing double latex gloves. Wearing steel weave outer gloves to undertake joint replacement surgery does not reduce the number of perforations to innermost gloves compared with double latex gloves.
Securing the future of natural rubber – an American tire and bio-energy platform from guayule
USDA-ARS?s Scientific Manuscript database
There is a high level of interest in alternative sources of natural rubber for the tire industry due to both the price and supply volatility of Hevea brasiliensis. The guayule plant (Parthenium argentatum) has served as a major source of domestic natural rubber in the early 20th century and is being...
STS-46 ESA MS Nicollier conducts IFM on OV-104's waste collection system
NASA Technical Reports Server (NTRS)
1992-01-01
STS-46 European Space Agency (ESA) Mission Specialist (MS) Claude Nicollier, wearing goggles, face mask, and rubber gloves, reviews inflight maintenance (IFM) checklist procedures before starting waste collection system (WCS) fan separator repair. One of two fan separators used to transfer waster water from the waste management compartment (WMC) to the waste water tank has failed. The suspected accumulation of water in the separator was believed to have occurred during a test dumping of waste water at a lower than normal pressure to evaluate the performance of new nozzles. The WMC is located on the middeck of Atlantis, Orbiter Vehicle (OV) 104.
Natural Rubber Quantification in Sunflower Using an Automated Solvent Extractor
USDA-ARS?s Scientific Manuscript database
Leaves of sunflower (Helianthus annuus) produce a small amount of low molecular weight natural rubber (NR) and this species has potential as a rubber-producing crop plant. Quantifying NR in plant tissue has traditionally been accomplished using Soxhlet or gravimetric methodologies. Accelerated solve...
Effect of non-rubber constituents on Guayule and Hevea rubber intrinsic properties
USDA-ARS?s Scientific Manuscript database
To meet the increasing demand for natural rubber (NR), currently sourced from the tropical rubber tree Hevea brasiliensis, and address price volatility and steadily increasing labor costs, alternate rubber-producing species are in commercial development. One of these, guayule (Parthenium argentatum)...
How risky are pinholes in gloves? A rational appeal for the integrity of gloves for isolators.
Gessler, Angela; Stärk, Alexandra; Sigwarth, Volker; Moirandat, Claude
2011-01-01
Isolators provide a high degree of protection for the product and/or the environment and operators in pharmaceutical production, as well as for analytical and sterility testing. Gloves allow for performing testing and for easy access to the process. Due to their nature-thin plastic, highly flexible-and their risk of puncture or rupture, they are regarded as one of the main potential sources of contamination. Glove integrity testing is therefore a main issue and has been addressed by many regulations such as those imposed by the USP, U.S. Food and Drug Administration, and Pharmaceutical Inspection Convention. This paper presents a short overview of different glove integrity test procedures and their ability to detect leaking gloves. Additionally, extensive microbiological tests have been performed to give more evidence and cross-correlation to physical testing. Most of the physical tests have limitations either in detecting pinholes and/or they are difficult to implement for routine testing. Microbiological tests are only applicable for evaluation and validation purposes, but not for routine testing, because they are time-consuming and do not allow immediate action. Routine visual verification of gloves by trained personnel turns out to be a very reliable technique. Additional microbiological tests supported by microbiological environmental monitoring helped to develop a new concept presented here on how to handle gloves with pinholes. It is proposed not to automatically consider a pinhole in a glove as a breach in isolator integrity, but to consider any action in view of controlling and monitoring the effective bioload on the outside of the gloves. With the combination of semi-automatic physical testing with independent protocol, visual inspection, and control of bioload through microbiological environmental monitoring potential contamination, risks can be minimized and maximum safety maintained. Isolators are enclosure designs to protect critical handling and process steps in pharmaceutical environments. They provide a high degree of protection for product and/or environment and operators against particles, potentially hazardous active principles, and microbial load. Gloves mounted on windows and doors of the isolator allow for manipulation, performing testing, and access to the process. Due to their nature and their use with risk of puncture or rupture, they are regarded as a potential source for contamination. Glove integrity testing has therefor been addressed by regulations such as those imposed by the USP and the Food and Drug Administration. This paper presents a short overview of various glove integrity test procedures and their ability to detect leaking gloves. Most of the tests have limitations either in detecting pinholes and/or they are difficult to implement for routine testing. Routine visual verification of gloves by trained personnel turns out to be a very reliable technique. Additional microbiological tests led to a new concept presented here on how to handle gloves with pinholes and how to take action. With this approach, risks can be minimized and maximum safety maintained by controlling and monitoring the effective bioload on the outside of the gloves.
Effect of microfluidized and stearic acid modified soy protein in natural rubber
USDA-ARS?s Scientific Manuscript database
Microfluidized and stearic acid modified soy protein aggregates were used to reinforced natural rubber. The size of soy protein particles was reduced with a microfluidizing and ball milling process. Filler size reduction with longer ball milling time tends to increase tensile strength of the rubber ...
Blends of guayule natural rubber latex with commercial latex polymers
USDA-ARS?s Scientific Manuscript database
Guayule (Parthenium argentatum) is a woody desert shrub that produces natural rubber, cis-1,4 polyisoprene, by biosynthesis. It is currently cultivated in the southwestern United States as a source of latex and rubber for commercial development. Guayule latex is similar to Hevea latex in polymer mo...
A study of protein and amino acids in guayule natural rubber
USDA-ARS?s Scientific Manuscript database
Natural rubber (NR) from Hevea brasiliensis (the Hevea rubber tree) is a critical agricultural material vital to United States industry, medicine, and defense, yet the country is dependent on NR imports to meet domestic needs. Parthenium argentatum (guayule), a woody desert shrub indigenous to the U...
Characterization of Engine Mount Elastomers
2005-02-01
blend of carbon black filled nitrile rubber ( NBR ), polyvinylchloride (PVC), and diisooctyl phthalate (DIOP) that was formulated at PSL (as AMRL 2046...a suitable replacement for natural rubber and neoprene rubber in engine mounts where exposure to hydrocarbon fluids is a concern. The data for NBR ...range 3-7 MPa. The loss factors of the elastomers at 1 Hz, 20oC varied considerably, from 0.02 for natural rubber to 0.27 for ethylene acrylic
USDA-ARS?s Scientific Manuscript database
Natural rubber (cis-1,4-polyisoprene) is an essential plant derived commodity required for the manufacture of numerous industrial, medical and household items. Rubber is synthesized and sequestered on cytsolic vesicles known as rubber particles. When provided with farnesyl pyrophosphate (FPP) and is...
Structural characterization of rubber from jackfruit and euphorbia as a model of natural rubber.
Mekkriengkrai, Dararat; Ute, Koiichi; Swiezewska, Ewa; Chojnacki, Tadeusz; Tanaka, Yasuyuki; Sakdapipanich, Jitladda T
2004-01-01
A structural study of low molecular weight rubbers from Jackfruit (Artocarpus heterophyllus) and Painted spurge (Euphorbia heterophylla) was carried out as model compounds of natural rubber from Hevea brasiliensis. The rubber content of latex from Jackfruit was 0.4-0.7%, which is very low compared with that of 30-35% in the latex from Hevea tree. The rubber from Jackfruit latex was low molecular weight with narrow unimodal molecular weight distribution (MWD), whereas that obtained from E. heterophylla showed very broad MWD. The 1H and 13C NMR analyses showed that Jackfruit rubber consists of a dimethylallyl group and two trans-isoprene units connected to a long sequence of cis-isoprene units. The alpha-terminal group of Jackfruit rubber was presumed to be composed of a phosphate group based on the presence of 1H NMR signal at 4.08 ppm corresponding to the terminal =CH-CH2OP group.
Shimada, Kunio; Mochizuki, Osamu; Kubota, Yoshihiro
2017-04-19
The aim of this study is to investigate the effect of particles as filler in soft rubber sensors installed in artificial skin. We examine sensors made of natural rubber (NR-latex) that include magnetic particles of Ni and Fe₃O₄ using magnetic compound fluid (MCF). The 1-mm thickness of the electrolytically polymerized MCF rubber makes production of comparatively thin rubber sensors feasible. We first investigate the effect of magnetic particles Ni and Fe₃O₄ on the curing of MCF rubber. Next, in order to adjust the electric properties of the MCF rubber, we adopt Al₂O₃ dielectric particles. We investigate the effect of Al₂O₃ particles on changes in electric current, voltage and temperature of electrolytically polymerized MCF rubber liquid, and on the electric properties under the application of normal and shear forces. By adjusting the ratio of Ni, Fe₃O₄, Al₂O₃ and water in MCF rubber with Al₂O₃, it is possible to change the electric properties.
Federal Specification MMM-A-1617B for Adhesive, Rubber-Base, General-Purpose HAP-Free Replacement
2011-05-01
A-1617B Type-I adhesive (table 1) (5). This adhesive is a natural rubber and SBR combination recommended for bonding cotton duck, leather , felt...cotton duck, leather , felt, and cork to themselves, aluminum, steel, or natural rubber (5). Clifton FA-1051 low-HAP (experimental) adhesive is...oils. This adhesive bonds leather , nitrile rubber, most plastics, and gasketing materials to a variety of substrates. The carrier solvent is acetone
THERMOOXIDATIVE STUDY OF RAW NATURAL RUBBER FROM BRAZILIAN IAC 300 SERIES CLONES
USDA-ARS?s Scientific Manuscript database
The improvement of rubber tree species is of key importance due to the worldwide market demand of this renewable material essential for several types of industries. The thermal performance of natural rubber produced from new clones of IAC 300 series, and the Malaysian RRIM 600 clone (used as control...
USDA-ARS?s Scientific Manuscript database
Natural rubber was reinforced with stearic acid modified soy protein particles prepared with a microfluidizing and ball milling process. Longer ball milling time tends to increase tensile strength of the rubber composites. Elastic modulus of the composites increased with the increasing filler concen...
USDA-ARS?s Scientific Manuscript database
Several proteins have been identified and implicated in natural rubber biosynthesis, one of which, the small rubber particle protein (SRPP), was originally identified in Hevea brasiliensis as an abundant protein associated with cytosolic vesicles known as rubber particles. While previous in vitro s...
Effects of forests, roads and mistletoe on bird diversity in monoculture rubber plantations
NASA Astrophysics Data System (ADS)
Sreekar, Rachakonda; Huang, Guohualing; Yasuda, Mika; Quan, Rui-Chang; Goodale, Eben; Corlett, Richard T.; Tomlinson, Kyle W.
2016-02-01
Rising global demand for natural rubber is expanding monoculture rubber (Hevea brasilensis) at the expense of natural forests in the Old World tropics. Conversion of forests into rubber plantations has a devastating impact on biodiversity and we have yet to identify management strategies that can mitigate this. We determined the life-history traits that best predict bird species occurrence in rubber plantations in SW China and investigated the effects of surrounding forest cover and distance to roads on bird diversity. Mistletoes provide nectar and fruit resources in rubber so we examined mistletoe densities and the relationship with forest cover and rubber tree diameter. In rubber plantations, we recorded less than half of all bird species extant in the surrounding area. Birds with wider habitat breadths and low conservation value had a higher probability of occurrence. Species richness and diversity increased logarithmically with surrounding forest cover, but roads had little effect. Mistletoe density increased exponentially with rubber tree diameters, but was unrelated to forest cover. To maximize bird diversity in rubber-dominated landscapes it is therefore necessary to preserve as much forest as possible, construct roads through plantations and not forest, and retain some large rubber trees with mistletoes during crop rotations.
Effects of forests, roads and mistletoe on bird diversity in monoculture rubber plantations.
Sreekar, Rachakonda; Huang, Guohualing; Yasuda, Mika; Quan, Rui-Chang; Goodale, Eben; Corlett, Richard T; Tomlinson, Kyle W
2016-02-23
Rising global demand for natural rubber is expanding monoculture rubber (Hevea brasilensis) at the expense of natural forests in the Old World tropics. Conversion of forests into rubber plantations has a devastating impact on biodiversity and we have yet to identify management strategies that can mitigate this. We determined the life-history traits that best predict bird species occurrence in rubber plantations in SW China and investigated the effects of surrounding forest cover and distance to roads on bird diversity. Mistletoes provide nectar and fruit resources in rubber so we examined mistletoe densities and the relationship with forest cover and rubber tree diameter. In rubber plantations, we recorded less than half of all bird species extant in the surrounding area. Birds with wider habitat breadths and low conservation value had a higher probability of occurrence. Species richness and diversity increased logarithmically with surrounding forest cover, but roads had little effect. Mistletoe density increased exponentially with rubber tree diameters, but was unrelated to forest cover. To maximize bird diversity in rubber-dominated landscapes it is therefore necessary to preserve as much forest as possible, construct roads through plantations and not forest, and retain some large rubber trees with mistletoes during crop rotations.
USDA-ARS?s Scientific Manuscript database
Natural rubber (NR) is a critical and strategic raw material for industrial manufacturing and national defense. Development of a US-based supply of NR is recognized in the Critical Agricultural Materials Act, Public Law 95–592. Domestic rubber-producing crops have been introduced in the US during ti...
Methacrylamide grafted elastomer composites reinforced with biobased particles
USDA-ARS?s Scientific Manuscript database
Modulus of rubber can be improved with grafting of unsaturated monomers. To increase the modulus of bio-based rubber composites, methacrylamide was grafted onto natural rubber composites reinforced with bio-based hydrophilic particles. Rubber particles in water were modified with methacrylamide usin...
Development of optical laser balloon and drainage from radiation vulcanized natural rubber latex
NASA Astrophysics Data System (ADS)
Shimamura, Yoshiyuki
Rubber film made of radiation vulcanized natural rubber latex (RVNRL) has better transparency and lower toxicity compared with sulfur-vulcanized latex film. Optical laser balloon (optical endoscopical balloon) and drainage were developed by using RVNRL. An endoscope was equipped with a saline-filled latex rubber balloon at its tip to displace contaminating blood, bile, or gastric contents during operative portoscopy, biliary endoscopy, or upper gastrointestinal endoscopy. The transmission of Nd-Yag laser through the balloon is 98%, higher than the sulfur-vulcanized latex rubber (75%). High transparency of the drainage bag facilitated easy observation of discharged fluids without detaching the bag from the tube.
Heitz, James W; Bader, Stephen O
2010-09-01
The prevalence of latex allergy is increasing in surgical patient populations. Avoidance of exposure to the allergen is essential to minimizing perioperative complications in patients suspected to be at risk. Natural rubber latex has historically been ubiquitous in medical devices containing rubber. In 1998, the Food and Drug Administration (FDA) began to require the labeling of medical devices made from natural rubber latex; since that time substantial progress has been made in identifying latex-free alternatives. However, the rubber stoppers commonly found in pharmaceutical vial closures are exempt from FDA labeling requirements. Examination of the clinical and basic science literature regarding pharmaceutical vial closures supports limiting the rubber stopper to a single needle puncture as a safer practice, with the caveat that no strategy exists for the complete elimination of risk as long as stoppers made from natural rubber latex are used in pharmaceutical vials intended for human use. Copyright © 2010 Elsevier Inc. All rights reserved.
Cerebrospinal fluid eosinophilia and sterile shunt malfunction.
Traynelis, V C; Powell, R G; Koss, W; Schochet, S S; Kaufman, H H
1988-11-01
Cerebrospinal fluid (CSF) eosinophilia is a rare finding most often associated with central nervous system inflammatory processes, including parasitic, bacterial, and mycotic infections. It has also been seen as an allergic phenomenon. We present two cases of CSF eosinophilia occurring concurrently with sterile shunt malfunction. We speculate that CSF eosinophilia in our patients might have resulted from an allergic response to a foreign material such as suture, surgical glove powder, hair, cotton fibers, antibiotics, or silicone rubber. The incidence of sterile CSF eosinophilia after shunting is not known. Information concerning the role of eosinophilia in the development of shunt malfunctions is also lacking. An increased awareness of this possibility and further investigation are warranted.
Shimada, Kunio; Mochizuki, Osamu; Kubota, Yoshihiro
2017-01-01
The aim of this study is to investigate the effect of particles as filler in soft rubber sensors installed in artificial skin. We examine sensors made of natural rubber (NR-latex) that include magnetic particles of Ni and Fe3O4 using magnetic compound fluid (MCF). The 1-mm thickness of the electrolytically polymerized MCF rubber makes production of comparatively thin rubber sensors feasible. We first investigate the effect of magnetic particles Ni and Fe3O4 on the curing of MCF rubber. Next, in order to adjust the electric properties of the MCF rubber, we adopt Al2O3 dielectric particles. We investigate the effect of Al2O3 particles on changes in electric current, voltage and temperature of electrolytically polymerized MCF rubber liquid, and on the electric properties under the application of normal and shear forces. By adjusting the ratio of Ni, Fe3O4, Al2O3 and water in MCF rubber with Al2O3, it is possible to change the electric properties. PMID:28422061
The rubber tree genome shows expansion of gene family associated with rubber biosynthesis.
Lau, Nyok-Sean; Makita, Yuko; Kawashima, Mika; Taylor, Todd D; Kondo, Shinji; Othman, Ahmad Sofiman; Shu-Chien, Alexander Chong; Matsui, Minami
2016-06-24
Hevea brasiliensis Muell. Arg, a member of the family Euphorbiaceae, is the sole natural resource exploited for commercial production of high-quality natural rubber. The properties of natural rubber latex are almost irreplaceable by synthetic counterparts for many industrial applications. A paucity of knowledge on the molecular mechanisms of rubber biosynthesis in high yield traits still persists. Here we report the comprehensive genome-wide analysis of the widely planted H. brasiliensis clone, RRIM 600. The genome was assembled based on ~155-fold combined coverage with Illumina and PacBio sequence data and has a total length of 1.55 Gb with 72.5% comprising repetitive DNA sequences. A total of 84,440 high-confidence protein-coding genes were predicted. Comparative genomic analysis revealed strong synteny between H. brasiliensis and other Euphorbiaceae genomes. Our data suggest that H. brasiliensis's capacity to produce high levels of latex can be attributed to the expansion of rubber biosynthesis-related genes in its genome and the high expression of these genes in latex. Using cap analysis gene expression data, we illustrate the tissue-specific transcription profiles of rubber biosynthesis-related genes, revealing alternative means of transcriptional regulation. Our study adds to the understanding of H. brasiliensis biology and provides valuable genomic resources for future agronomic-related improvement of the rubber tree.
Computational Analysis of the G-III Laminar Flow Glove
NASA Technical Reports Server (NTRS)
Malik, Mujeeb R.; Liao, Wei; Lee-Rausch, Elizabeth M.; Li, Fei; Choudhari, Meelan M.; Chang, Chau-Lyan
2011-01-01
Under NASA's Environmentally Responsible Aviation Project, flight experiments are planned with the primary objective of demonstrating the Discrete Roughness Elements (DRE) technology for passive laminar flow control at chord Reynolds numbers relevant to transport aircraft. In this paper, we present a preliminary computational assessment of the Gulfstream-III (G-III) aircraft wing-glove designed to attain natural laminar flow for the leading-edge sweep angle of 34.6deg. Analysis for a flight Mach number of 0.75 shows that it should be possible to achieve natural laminar flow for twice the transition Reynolds number ever achieved at this sweep angle. However, the wing-glove needs to be redesigned to effectively demonstrate passive laminar flow control using DREs. As a by-product of the computational assessment, effect of surface curvature on stationary crossflow disturbances is found to be strongly stabilizing for the current design, and it is suggested that convex surface curvature could be used as a control parameter for natural laminar flow design, provided transition occurs via stationary crossflow disturbances.
USDA-ARS?s Scientific Manuscript database
Natural rubber biosynthesis in guayule (Parthenium argentatum) is associated with moderately cold night temperatures. To begin to dissect the molecular events triggered by cold temperatures that govern rubber synthesis induction in guayule, the transcriptome of bark tissue, where rubber is produced...
A sustainability review of domestic rubber from the guayule plant
USDA-ARS?s Scientific Manuscript database
Guayule (Parthenium argentatum Gray) is an arid-adapted, low-input perennial shrub native to Mexico and southern Texas that has received considerable attention as an alternative source of natural rubber. It has potential to replace the most common types of rubbers, including synthetic rubber derived...
NASA Astrophysics Data System (ADS)
Yusof, Muhammad Jefri Mohd; Jamaluddin, Naharullah; Abdullah, Ibrahim; Yusoff, Siti Fairus M.
2015-09-01
Liquid natural rubber (LNR) with molecular weight of lower than 105 and shorter polymeric chain than natural rubber was prepared. LNR was then hydrogenated via diimide reduction by oxidation of hydrazine hydrate with hydrogen peroxide. The unsaturated units of the rubber were converted into saturated hydrocarbon to strengthen the backbone of the polymer so it was able to resist thermal degradation. The results indicated that hydrogenation degree of the product (HLNR) could be extended to 91.2% conversion under appropriate conditions. The hydrogenated LNR (HLNR) was characterized using Fourier-Transform Infrared (FTIR) and Nuclear Magnetic Resonance (NMR) spectroscopy. The physical characteristics of HLNR were analyzed with Termogravimetric Analysis (TGA).
... infants, school age, and adolescent/young adult. Latex (Natural Rubber) Allergy Many people with spina bifida are allergic to products that contain latex, or natural rubber. This means they should not use items ...
Collins-Silva, Jillian; Nural, Aise Taban; Skaggs, Amanda; Scott, Deborah; Hathwaik, Upul; Woolsey, Rebekah; Schegg, Kathleen; McMahan, Colleen; Whalen, Maureen; Cornish, Katrina; Shintani, David
2012-07-01
Several proteins have been identified and implicated in natural rubber biosynthesis, one of which, the small rubber particle protein (SRPP), was originally identified in Hevea brasiliensis as an abundant protein associated with cytosolic vesicles known as rubber particles. While previous in vitro studies suggest that SRPP plays a role in rubber biosynthesis, in vivo evidence is lacking to support this hypothesis. To address this issue, a transgene approach was taken in Taraxacum kok-saghyz (Russian dandelion or Tk) to determine if altered SRPP levels would influence rubber biosynthesis. Three dandelion SRPPs were found to be highly abundant on dandelion rubber particles. The most abundant particle associated SRPP, TkSRPP3, showed temporal and spatial patterns of expression consistent with patterns of natural rubber accumulation in dandelion. To confirm its role in rubber biosynthesis, TkSRPP3 expression was altered in Russian dandelion using over-expression and RNAi methods. While TkSRPP3 over-expressing lines had slightly higher levels of rubber in their roots, relative to the control, TkSRPP3 RNAi lines showed significant decreases in root rubber content and produced dramatically lower molecular weight rubber than the control line. Not only do results here provide in vivo evidence of TkSRPP proteins affecting the amount of rubber in dandelion root, but they also suggest a function in regulating the molecular weight of the cis-1, 4-polyisoprene polymer. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiang, Cheng Ching K.; Barkakaty, Balaka; Puskas, Judit E.
The superior properties of natural rubber (cis-1,4-polyisoprene [NR]) are a function of its structure and composition, properties that still remain a mystery and that are irreplaceable by any synthetic rubber. NR from guayule (Parthenium argentatum) has been gaining special interest for its hypoallergenic properties while maintaining superior mechanical properties that are commonly associated with the Brazilian rubber tree (Hevea brasiliensis), the most common source of NR. Techniques exist to isolate washed rubber particles (WRPs) that contain enzymatically active rubber transferase, to study NR biosynthesis, and previous work on the in vitroNRgrowth in Hevea has demonstrated the presence of around 50wt%ofmore » a low molecular weight ([MW], Mn <10 000 g/mol) fraction. Structural and compositional analyses of this low MW fraction in Hevea are challenging due to the high protein content. Here, we discuss the analysis and composition of guayule latex and WRPs using high-resolution Size Exclusion Chromatography. We also discuss the composition of the soluble fraction of inactive guayule latex using matrix-assisted laser desorption ionization/time of flight mass spectrometry.« less
Xu, Chuanhui; Cao, Liming; Lin, Baofeng; Liang, Xingquan; Chen, Yukun
2016-07-13
Introducing ionic associations is one of the most effective approaches to realize a self-healing behavior for rubbers. However, most of commercial rubbers are nonpolar rubbers without now available functional groups to be converted into ionic groups. In this paper, our strategy was based on a controlled peroxide-induced vulcanization to generate massive ionic cross-links via polymerization of zinc dimethacrylate (ZDMA) in natural rubber (NR) and exploited it as a potential self-healable material. We controlled vulcanization process to retard the formation of covalent cross-link network, and successfully generated a reversible supramolecular network mainly constructed by ionic cross-links. Without the restriction of covalent cross-linkings, the NR chains in ionic supramolecular network had good flexibility and mobility. The nature that the ionic cross-links was easily reconstructed and rearranged facilitating the self-healing behavior, thereby enabling a fully cut sample to rejoin and retain to its original properties after a suitable self-healing process at ambient temperature. This study thus demonstrates a feasible approach to impart an ionic association induced self-healing function to commercial rubbers without ionic functional groups.
Effects of forests, roads and mistletoe on bird diversity in monoculture rubber plantations
Sreekar, Rachakonda; Huang, Guohualing; Yasuda, Mika; Quan, Rui-Chang; Goodale, Eben; Corlett, Richard T.; Tomlinson, Kyle W.
2016-01-01
Rising global demand for natural rubber is expanding monoculture rubber (Hevea brasilensis) at the expense of natural forests in the Old World tropics. Conversion of forests into rubber plantations has a devastating impact on biodiversity and we have yet to identify management strategies that can mitigate this. We determined the life-history traits that best predict bird species occurrence in rubber plantations in SW China and investigated the effects of surrounding forest cover and distance to roads on bird diversity. Mistletoes provide nectar and fruit resources in rubber so we examined mistletoe densities and the relationship with forest cover and rubber tree diameter. In rubber plantations, we recorded less than half of all bird species extant in the surrounding area. Birds with wider habitat breadths and low conservation value had a higher probability of occurrence. Species richness and diversity increased logarithmically with surrounding forest cover, but roads had little effect. Mistletoe density increased exponentially with rubber tree diameters, but was unrelated to forest cover. To maximize bird diversity in rubber-dominated landscapes it is therefore necessary to preserve as much forest as possible, construct roads through plantations and not forest, and retain some large rubber trees with mistletoes during crop rotations. PMID:26903032
NASA Astrophysics Data System (ADS)
Suharty, N. S.; Ismail, H.; Diharjo, K.; Handayani, D. S.; Saputri, L. N. M. Z.; Ariesta, N.
2018-03-01
Had been synthesized PP/rRG/MMt+ZB smart material composite in solution reactive processes with various rRG concentration. The addition of rRG plasticizers will improve the deflection properties and increase the filler capacity MMt loading to reach the optimum concentration. The addition of 3% rRG is capable of loading filler capacity MMt to 23% as the optimum condition. At the optimum conditions it can increase the deflection (Defl) and flexural strength (FS) up to 16% and 15% respectively compared to that of the composites without rRG. The rRG plasticizer serves as a bio-compatibilizer that can reduce surface tension of the mixture and leads to decrease the Defl., follow by the increase of loading filler capacity and well interaction finally can increase the FS properties. The increase of loading filler MMt up to 23% can also improve the inflammability of the composites. Time to Ignition (TTI) increase by 5% and Burning Rate (BR) decrease by 4.5% compared to that of the composites which is containing MMt 20% without rRG.
Characterization of rubber particles and rubber chain elongation in Taraxacum koksaghyz
2010-01-01
Background Natural rubber is a biopolymer with exceptional qualities that cannot be completely replaced using synthetic alternatives. Although several key enzymes in the rubber biosynthetic pathway have been isolated, mainly from plants such as Hevea brasiliensis, Ficus spec. and the desert shrub Parthenium argentatum, there have been no in planta functional studies, e.g. by RNA interference, due to the absence of efficient and reproducible protocols for genetic engineering. In contrast, the Russian dandelion Taraxacum koksaghyz, which has long been considered as a potential alternative source of low-cost natural rubber, has a rapid life cycle and can be genetically transformed using a simple and reliable procedure. However, there is very little molecular data available for either the rubber polymer itself or its biosynthesis in T. koksaghyz. Results We established a method for the purification of rubber particles - the active sites of rubber biosynthesis - from T. koksaghyz latex. Photon correlation spectroscopy and transmission electron microscopy revealed an average particle size of 320 nm, and 13C nuclear magnetic resonance (NMR) spectroscopy confirmed that isolated rubber particles contain poly(cis-1,4-isoprene) with a purity >95%. Size exclusion chromatography indicated that the weight average molecular mass (w) of T. koksaghyz natural rubber is 4,000-5,000 kDa. Rubber particles showed rubber transferase activity of 0.2 pmol min-1 mg-1. Ex vivo rubber biosynthesis experiments resulted in a skewed unimodal distribution of [1-14C]isopentenyl pyrophosphate (IPP) incorporation at a w of 2,500 kDa. Characterization of recently isolated cis-prenyltransferases (CPTs) from T. koksaghyz revealed that these enzymes are associated with rubber particles and are able to produce long-chain polyprenols in yeast. Conclusions T. koksaghyz rubber particles are similar to those described for H. brasiliensis. They contain very pure, high molecular mass poly(cis-1,4-isoprene) and the chain elongation process can be studied ex vivo. Because of their localization on rubber particles and their activity in yeast, we propose that the recently described T. koksaghyz CPTs are the major rubber chain elongating enzymes in this species. T. koksaghyz is amenable to genetic analysis and modification, and therefore could be used as a model species for the investigation and comparison of rubber biosynthesis. PMID:20170509
Kotowska, Martyna M; Leuschner, Christoph; Triadiati, Triadiati; Meriem, Selis; Hertel, Dietrich
2015-10-01
Natural forests in South-East Asia have been extensively converted into other land-use systems in the past decades and still show high deforestation rates. Historically, lowland forests have been converted into rubber forests, but more recently, the dominant conversion is into oil palm plantations. While it is expected that the large-scale conversion has strong effects on the carbon cycle, detailed studies quantifying carbon pools and total net primary production (NPPtotal ) in above- and belowground tree biomass in land-use systems replacing rainforest (incl. oil palm plantations) are rare so far. We measured above- and belowground carbon pools in tree biomass together with NPPtotal in natural old-growth forests, 'jungle rubber' agroforests under natural tree cover, and rubber and oil palm monocultures in Sumatra. In total, 32 stands (eight plot replicates per land-use system) were studied in two different regions. Total tree biomass in the natural forest (mean: 384 Mg ha(-1) ) was more than two times higher than in jungle rubber stands (147 Mg ha(-1) ) and >four times higher than in monoculture rubber and oil palm plantations (78 and 50 Mg ha(-1) ). NPPtotal was higher in the natural forest (24 Mg ha(-1) yr(-1) ) than in the rubber systems (20 and 15 Mg ha(-1) yr(-1) ), but was highest in the oil palm system (33 Mg ha(-1) yr(-1) ) due to very high fruit production (15-20 Mg ha(-1) yr(-1) ). NPPtotal was dominated in all systems by aboveground production, but belowground productivity was significantly higher in the natural forest and jungle rubber than in plantations. We conclude that conversion of natural lowland forest into different agricultural systems leads to a strong reduction not only in the biomass carbon pool (up to 166 Mg C ha(-1) ) but also in carbon sequestration as carbon residence time (i.e. biomass-C:NPP-C) was 3-10 times higher in the natural forest than in rubber and oil palm plantations. © 2015 John Wiley & Sons Ltd.
Development of Bushing Compounds for Tracked Vehicles
1990-10-01
unwanted stepchild - part of called anti patented NBR -12 formulation the family (system), but devoid of needed indicated that service life could be...as Development and Engineering Center’s long. Bushings currently used in the M I track Rubber and Coated Fabrics Research Group assembly typically fail...formulations of should be improved. Numerous selected candidate natural rubber , propylene formulations-based on natural rubber , oxide, and silicone
Korinth, G; Weiss, T; Penkert, S; Schaller, K H; Angerer, J; Drexler, H
2007-01-01
Background Several aromatic amines (AA) could cause bladder cancer and are an occupational hygiene problem in the workplace. However, little is known about the percutaneous absorption of chemicals via impaired skin and about the efficacy of skin protection measures to reduce internal exposure. Aims To determine the impact of skin status and of skin protection measures on the internal exposure to AA in workers manufacturing rubber products. Methods 51 workers occupationally exposed to aniline and o‐toluidine were examined. The workplace conditions, risk factors for skin and the use of personal protective equipment were assessed by means of a self‐administered questionnaire. The skin of hands and forearms was clinically examined. Exposure to aniline and o‐toluidine was assessed by ambient air and biological monitoring (analyses of urine samples and of haemoglobin adducts). Results Haemoglobin‐AA‐adduct levels in workers with erythema (73%) were significantly higher (p<0.04) than in workers with healthy skin (mean values: aniline 1150.4 ng/l vs 951.7 ng/l, o‐toluidine 417.9 ng/l vs 118.3 ng/l). The multiple linear regression analysis showed that wearing gloves significantly reduced the internal exposure. A frequent use of skin barrier creams leads to a higher internal exposure of AA (p<0.03). However, the use of skincare creams at the workplace was associated with a reduced internal exposure (p<0.03). From these findings we assume that internal exposure of the workers resulted primarily from the percutaneous uptake. Conclusions The study demonstrates a significantly higher internal exposure to AA in workers with impaired skin compared with workers with healthy skin. Daily wearing of gloves efficiently reduced internal exposure. However, an increased use of skin barrier creams enhances the percutaneous uptake of AA. Skincare creams seem to support skin regeneration and lead to reduced percutaneous uptake. PMID:17182646
Suntornsut, Pornpan; Wongsuwan, Nittayasee; Malasit, Mayura; Kitphati, Rungreung; Michie, Susan; Peacock, Sharon J; Limmathurotsakul, Direk
2016-07-01
Melioidosis, an often fatal infectious disease in Northeast Thailand, is caused by skin inoculation, inhalation or ingestion of the environmental bacterium, Burkholderia pseudomallei. The major underlying risk factor for melioidosis is diabetes mellitus. Recommendations for melioidosis prevention include using protective gear such as rubber boots and gloves when in direct contact with soil and environmental water, and consuming bottled or boiled water. Only a small proportion of people follow such recommendations. Nine focus group discussions were conducted to evaluate barriers to adopting recommended preventive behaviours. A total of 76 diabetic patients from northeast Thailand participated in focus group sessions. Barriers to adopting the recommended preventive behaviours and future intervention strategies were identified using two frameworks: the Theoretical Domains Framework and the Behaviour Change Wheel. Barriers were identified in the following five domains: (i) knowledge, (ii) beliefs about consequences, (iii) intention and goals, (iv) environmental context and resources, and (v) social influence. Of 76 participants, 72 (95%) had never heard of melioidosis. Most participants saw no harm in not adopting recommended preventive behaviours, and perceived rubber boots and gloves to be hot and uncomfortable while working in muddy rice fields. Participants reported that they normally followed the behaviour of friends, family and their community, the majority of whom did not wear boots while working in rice fields and did not boil water before drinking. Eight intervention functions were identified as relevant for the intervention: (i) education, (ii) persuasion, (iii) incentivisation, (iv) coercion, (v) modeling, (vi) environmental restructuring, (vii) training, and (viii) enablement. Participants noted that input from role models in the form of physicians, diabetic clinics, friends and families, and from the government via mass media would be required for them to change their behaviours. There are numerous barriers to the adoption of behaviours recommended for melioidosis prevention. We recommend that a multifaceted intervention at community and government level is required to achieve the desired behaviour changes.
Hayashi, C; Tokura, H
2000-04-01
Thermoregulatory responses were compared under two experimental conditions, in the laboratory (Experiment I), and in the field (Experiment II), between two kinds of protective clothing for spraying pesticides. One was currently being used (Type A), and was composed of ready made Gore-Tex clothing, mask, polyurethane gloves and rubber boots. The other one was newly designed (Type B), and was composed of pesticide-proof clothing (100% cotton with water repellent finish), mask, Gore-Tex gloves, and special boots consisting of rubber for the feet and ankle and Gore-Tex around the legs. In addition, the head and chest were cooled by frozen gel strips fixed in the cap and undershirt. In Experiment I, five female adults took part, in a climate-chamber controlled at an ambient temperature of 28 degrees C and a relative humidity of 60%. In Experiment II, five farmers (one male and four female) were tested in an apple orchard in July, August and September. The main results are summarized as follows: (1) change of rectal temperature was inhibited more effectively in Type B in Experiment I, (2) change of heart rate tended to be lower in Type B than in Type A in both experiments, (3) salivary lactic acid concentration at the end of the first exercise was significantly higher in Type A than in Type B in Experiment I, (4) the number of contractions in the handgrip exercise which was performed immediately after the third exercise, was significantly smaller in Type A than in Type B in Experiment I, (5) subjective comfort sensation was significantly improved in Type B in Experiments I and II. Thus, it was concluded that the newly designed protective clothing could reduce thermal stress during the spraying of pesticides in an apple orchard in summer.
Suntornsut, Pornpan; Wongsuwan, Nittayasee; Malasit, Mayura; Kitphati, Rungreung; Michie, Susan; Peacock, Sharon J.
2016-01-01
Background Melioidosis, an often fatal infectious disease in Northeast Thailand, is caused by skin inoculation, inhalation or ingestion of the environmental bacterium, Burkholderia pseudomallei. The major underlying risk factor for melioidosis is diabetes mellitus. Recommendations for melioidosis prevention include using protective gear such as rubber boots and gloves when in direct contact with soil and environmental water, and consuming bottled or boiled water. Only a small proportion of people follow such recommendations. Methods Nine focus group discussions were conducted to evaluate barriers to adopting recommended preventive behaviours. A total of 76 diabetic patients from northeast Thailand participated in focus group sessions. Barriers to adopting the recommended preventive behaviours and future intervention strategies were identified using two frameworks: the Theoretical Domains Framework and the Behaviour Change Wheel. Results Barriers were identified in the following five domains: (i) knowledge, (ii) beliefs about consequences, (iii) intention and goals, (iv) environmental context and resources, and (v) social influence. Of 76 participants, 72 (95%) had never heard of melioidosis. Most participants saw no harm in not adopting recommended preventive behaviours, and perceived rubber boots and gloves to be hot and uncomfortable while working in muddy rice fields. Participants reported that they normally followed the behaviour of friends, family and their community, the majority of whom did not wear boots while working in rice fields and did not boil water before drinking. Eight intervention functions were identified as relevant for the intervention: (i) education, (ii) persuasion, (iii) incentivisation, (iv) coercion, (v) modeling, (vi) environmental restructuring, (vii) training, and (viii) enablement. Participants noted that input from role models in the form of physicians, diabetic clinics, friends and families, and from the government via mass media would be required for them to change their behaviours. Conclusion There are numerous barriers to the adoption of behaviours recommended for melioidosis prevention. We recommend that a multifaceted intervention at community and government level is required to achieve the desired behaviour changes. PMID:27472421
The rubber tree genome shows expansion of gene family associated with rubber biosynthesis
Lau, Nyok-Sean; Makita, Yuko; Kawashima, Mika; Taylor, Todd D.; Kondo, Shinji; Othman, Ahmad Sofiman; Shu-Chien, Alexander Chong; Matsui, Minami
2016-01-01
Hevea brasiliensis Muell. Arg, a member of the family Euphorbiaceae, is the sole natural resource exploited for commercial production of high-quality natural rubber. The properties of natural rubber latex are almost irreplaceable by synthetic counterparts for many industrial applications. A paucity of knowledge on the molecular mechanisms of rubber biosynthesis in high yield traits still persists. Here we report the comprehensive genome-wide analysis of the widely planted H. brasiliensis clone, RRIM 600. The genome was assembled based on ~155-fold combined coverage with Illumina and PacBio sequence data and has a total length of 1.55 Gb with 72.5% comprising repetitive DNA sequences. A total of 84,440 high-confidence protein-coding genes were predicted. Comparative genomic analysis revealed strong synteny between H. brasiliensis and other Euphorbiaceae genomes. Our data suggest that H. brasiliensis’s capacity to produce high levels of latex can be attributed to the expansion of rubber biosynthesis-related genes in its genome and the high expression of these genes in latex. Using cap analysis gene expression data, we illustrate the tissue-specific transcription profiles of rubber biosynthesis-related genes, revealing alternative means of transcriptional regulation. Our study adds to the understanding of H. brasiliensis biology and provides valuable genomic resources for future agronomic-related improvement of the rubber tree. PMID:27339202
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yusof, Muhammad Jefri Mohd; Jamaluddin, Naharullah; Abdullah, Ibrahim
Liquid natural rubber (LNR) with molecular weight of lower than 10{sup 5} and shorter polymeric chain than natural rubber was prepared. LNR was then hydrogenated via diimide reduction by oxidation of hydrazine hydrate with hydrogen peroxide. The unsaturated units of the rubber were converted into saturated hydrocarbon to strengthen the backbone of the polymer so it was able to resist thermal degradation. The results indicated that hydrogenation degree of the product (HLNR) could be extended to 91.2% conversion under appropriate conditions. The hydrogenated LNR (HLNR) was characterized using Fourier-Transform Infrared (FTIR) and Nuclear Magnetic Resonance (NMR) spectroscopy. The physical characteristicsmore » of HLNR were analyzed with Termogravimetric Analysis (TGA)« less
Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P
2018-01-01
The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused amplification of handle vibration at the fingers. The fingers' vibration transmission performance of gloves were further evaluated using a proposed finger frequency-weighting W f apart from the standardized W h -weighting. It is shown that the W h weighting generally overestimates the VR glove effectiveness in limiting the fingers vibration in the high (H: 200-1250 Hz) frequency range. Both the weightings, however, revealed comparable performance of gloves in the mid (M: 25-200 Hz) frequency range. The VR gloves, with the exception of the leather glove, showed considerable reductions in the grip strength (27-41%), while the grip strength reduction was not correlated with the glove material thickness. It is suggested that effectiveness of VR gloves should be assessed considering the vibration transmission to both the palm and fingers of the hand together with the hand grip strength reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.
Simulated microbe removal around finger rings using different hand sanitation methods.
Alur, Archana A; Rane, Madhavi J; Scheetz, James P; Lorenz, Douglas J; Gettleman, Lawrence
2009-09-01
It is our opinion that the CDC and the WHO have underestimated cross-contamination under examination gloves in dental clinics while wearing jewelry, such as finger rings. These agencies only "recommend" removing jewelry, and only washing hands for 15 seconds with soap and warm water before donning gloves. This study examined several washing procedures and finger rings using simulated microbes. A gloved rubber hand manikin was made and fitted with a fresh disposable vinyl glove. Four fingers were fitted with rings or no ring, dusted with simulated microbes, and washed with a scrub brush for 5, 15, and 25 seconds under 20 degrees C and 40 degrees C water alone, or with liquid hand soap. Light levels (in lux) of fluorescent powder before and after washing were measured and delta scores calculated for changes in light levels, equivalent to effectiveness of hand washing procedures. A full-factorial, 3-factor analysis of variance (ANOVA) was used to test for differences among levels of the three study factors-time, temperature, and soap use. Tukey's post hoc honestly significant difference (HSD) test was applied to significant factors to examine pair-wise differences between factor levels. It was found that the longer the hands with rings were washed with a scrub brush under flowing water, the more simulated microbes were removed. By 25 seconds, all methods were essentially the same. Simulated microbes were more difficult to remove from the palm compared to the back of the hand. The liquid hand soap used in this study was more effective with warm water than cold. When given a choice of washing with cold water up to 15 seconds, it would be preferable not to use soap to remove simulated microbes. Qualitatively, the outer surface of finger rings were more effectively cleaned than the crevice below the ring, and the ring with a stone setting appeared to accumulate and retain simulated microbes more than other rings. The most effective treatment was washing with warm water and liquid soap. Longer times were more effective. Rings should not be worn under examination gloves due to difficulty cleaning in the crevice under the ring, and the well-known consequences of cross-contamination between the patient and the health care worker.
Hardness and compression resistance of natural rubber and synthetic rubber mixtures
NASA Astrophysics Data System (ADS)
Arguello, J. M.; Santos, A.
2016-02-01
This project aims to mechanically characterize through compression resistance and shore hardness tests, the mixture of hevea brasiliensis natural rubber with butadiene synthetic rubber (BR), styrene-butadiene rubber (SBR) and ethylene-propylene-diene monomer rubber (EPDM). For each of the studied mixtures were performed 10 tests, each of which increased by 10% the content of synthetic rubber in the mixture; each test consisted of carrying out five tests of compression resistance and five tests of shore hardness. The specimens were vulcanized on a temperature of 160°C, during an approximate time of 15 minutes, and the equipment used in the performance of the mechanical tests were a Shimadzu universal machine and a digital durometer. The results show that the A shore hardness increases directly proportional, with a linear trend, with the content of synthetic BR, SBR or EPDM rubber present in the mixture, being the EPDM the most influential. With respect to the compression resistance is observed that the content of BR or SBR increase this property directly proportional through a linear trend; while the EPDM content also increases but with a polynomial trend.
NASA Astrophysics Data System (ADS)
Abdul Hamid, Siti Atkah; Abdullah, Mustaffa Hj.; Ahmad, Sahrim Hj.; Mansor, Abdul Aziz; Yusoff, Ahmad Nazlim
2002-09-01
A microwave (Li0.5Fe0.5)0.4Ni0.3Zn0.3Fe2O4 (LNZ) ferrite was prepared by a conventional sintering method in air. Thermoplastic natural rubber (TPNR) was prepared from polypropylene (PP) and natural rubber (NR) in the ratios of 80:20, 70:30, 60:40, 50:50 and 40:60 with liquid natural rubber as a compatibilizer by a melt blending technique. LNZ ferrite-TPNR composites with 20 wt% ferrite filler were prepared using a Brabender plasticorder internal mixer. The microwave electromagnetic properties of the composites were studied in the frequency range of 0.3-13.5 GHz using a microwave vector network analyzer (MVNA). The real and imaginary components of the relative complex dielectric permittivity (\\varepsilonr*=\\varepsilonr\\prime-j\\varepsilonr\\prime\\prime) and magnetic permeability (μr*=μr\\prime-jμr\\prime\\prime) were calculated from the measured complex scattering parameters (S11* and S12*) using the Nicolson-Ross model. The dielectric and magnetic properties were found to depend on the NR and PP content in the composites. The minimum reflection loss (RL) under the matching conditions increases with increasing NR content.
Wang, Xuchu; Wang, Dan; Sun, Yong; Yang, Qian; Chang, Lili; Wang, Limin; Meng, Xueru; Huang, Qixing; Jin, Xiang; Tong, Zheng
2015-09-08
Ethylene is a stimulant to increase natural rubber latex. After ethylene application, both fresh yield and dry matter of latex are substantially improved. Moreover, we found that ethylene improves the generation of small rubber particles. However, most genes involved in rubber biosynthesis are inhibited by exogenous ethylene. Therefore, we conducted a proteomics analysis of ethylene-stimulated rubber latex, and identified 287 abundant proteins as well as 143 ethylene responsive latex proteins (ERLPs) with mass spectrometry from the 2-DE and DIGE gels, respectively. In addition, more than 1,600 proteins, including 404 ERLPs, were identified by iTRAQ. Functional classification of ERLPs revealed that enzymes involved in post-translational modification, carbohydrate metabolism, hydrolase activity, and kinase activity were overrepresented. Some enzymes for rubber particle aggregation were inhibited to prolong latex flow, and thus finally improved latex production. Phosphoproteomics analysis identified 59 differential phosphoproteins; notably, specific isoforms of rubber elongation factor and small rubber particle protein that were phosphorylated mainly at serine residues. This post-translational modification and isoform-specific phosphorylation might be important for ethylene-stimulated latex production. These results not only deepen our understanding of the rubber latex proteome but also provide new insights into the use of ethylene to stimulate rubber latex production.
Shimada, Kunio
2018-06-06
In the series of studies on new types of elastic and compressible artificial skins with hybrid sensing functions, photovoltaics, and battery, we have proposed a hybrid skin (H-Skin) by utilizing an electrolytically polymerized magnetic compound fluid (MCF) made of natural rubber latex (NR-latex). By using the experimental results in the first and second reports, we have clarified the feasibility of electric charge at irradiation, and that without illumination under compression and elongation. The former was explained in a wet-type MCF rubber solar cell by developing a tunneling theory together with an equivalent electric circuit model. The latter corresponds to the battery rather than to the solar cell. As for the MCF rubber battery, depending on the selected agent type, we can make the MCF rubber have higher electricity and lighter weight. Therefore, the MCF rubber has an electric charge and storage whether at irradiation or not.
Natural Rubber Nanocomposite with Human-Tissue-Like Mechanical Characteristic
NASA Astrophysics Data System (ADS)
Murniati, Riri; Novita, Nanda; Sutisna; Wibowo, Edy; Iskandar, Ferry; Abdullah, Mikrajuddin
2017-07-01
The blends of synthetic rubber and natural rubber with nanosilica were prepared using a blending technique in presence of different filler volume fraction. The effect of filler on morphological and mechanical characteristics was studied. Utilization of human cadaver in means of medical study has been commonly used primarily as tools of medical teaching and training such as surgery. Nonetheless, human cadaver brought inevitable problems. So it is necessary to find a substitute material that can be used to replace cadavers. In orthopaedics, the materials that resemble in mechanical properties to biological tissues are elastomers such as natural rubber (latex) and synthetic rubber (polyurethanes, silicones). This substitution material needs to consider the potential of Indonesia to help the development of the nation. Indonesia is the second largest country producer of natural rubber in the world. This paper aims to contribute to adjusting the mechanical properties of tissue-mimicking materials (TMMs) to the recommended range of biological tissue value and thus allow the development of phantoms with greater stability and similarity to human tissues. Repeatability for the phantom fabrication process was also explored. Characteristics were then compared to the control and mechanical characteristics of different human body part tissue. Nanosilica is the best filler to produce the best nanocomposite similarities with human tissue. We produced composites that approaching the properties of human internal tissues.
Monitoring rubber plantation expansion using Landsat data time series and a Shapelet-based approach
NASA Astrophysics Data System (ADS)
Ye, Su; Rogan, John; Sangermano, Florencia
2018-02-01
The expansion of tree plantations in tropical forests for commercial rubber cultivation threatens biodiversity which may affect ecosystem services, and hinders ecosystem productivity, causing net carbon emission. Numerous studies refer to the challenge of reliably distinguishing rubber plantations from natural forest, using satellite data, due to their similar spectral signatures, even when phenology is incorporated into an analysis. This study presents a novel approach for monitoring the establishment and expansion of rubber plantations in Seima Protection Forest (SPF), Cambodia (1995-2015), by detecting and analyzing the 'shapelet' structure in a Landsat-NDVI time series. This paper introduces a new classification procedure consisting of two steps: (1) an exhaustive-searching algorithm to detect shapelets that represent a period for relatively low NDVI values within an image time series; and (2) a t-test used to determine if NDVI values of detected shapelets are significantly different than their non-shapelet trend, thereby indicating the presence of rubber plantations. Using this approach, historical rubber plantation events were mapped over the twenty-year timespan. The shapelet algorithm produced two types of information: (1) year of rubber plantation establishment; and (2) pre-conversion land-cover type (i.e., agriculture, or natural forest). The overall accuracy of the rubber plantation map for the year of 2015 was 89%. The multi-temporal map products reveal that more than half of the rubber planting activity (57%) took place in 2010 and 2011, following the granting of numerous rubber concessions two years prior. Seventy-three percent of the rubber plantations were converted from natural forest and twenty-three percent were established on non-forest land-cover. The shapelet approach developed here can be used reliably to improve our understanding of the expansion of rubber production beyond Seima Protection Forest of Cambodia, and likely elsewhere in the tropics.
Hoeprich, Paul D.; Whalen, Maureen
2016-04-05
Provided herein are nanolipoprotein particles that comprise a biosynthetic enzyme more particularly an enzyme capable of catalyzing rubber or other rubbers polymerization, and related assemblies, devices, methods and systems.
Wang, Dan; Sun, Yong; Chang, Lili; Tong, Zheng; Xie, Quanliang; Jin, Xiang; Zhu, Liping; He, Peng; Li, Hongbin; Wang, Xuchu
2018-06-30
Rubber particle (RP) is a specific organelle for natural rubber biosynthesis (NRB) and storage in rubber tree Hevea brasiliensis. NRB is processed by RP membrane-localized proteins, which were traditionally purified by repeated washing. However, we noticed many proteins in the discarded washing solutions (WS) from RP. Here, we compared the proteome profiles of WS, C-serum (CS) and RP by 2-DE, and identified 233 abundant proteins from WS by mass spectrometry. Many spots on 2-DE gels were identified as different protein species. We further performed shotgun analysis of CS, WS and RP and identified 1837, 1799 and 1020 unique proteins, respectively. Together with 2-DE, we finally identified 1825 proteins from WS, 246 were WS-specific. These WS-specific proteins were annotated in Gene Ontology, indicating most abundant pathways are organic substance metabolic process, protein degradation, primary metabolic process, and energy metabolism. Protein-protein interaction analysis revealed these WS-specific proteins are mainly involved in ribosomal metabolism, proteasome system, vacuolar protein sorting and endocytosis. Label free and Western blotting revealed many WS-specific proteins and protein complexes are crucial for NRB initiation. These findings not only deepen our understanding of WS proteome, but also provide new evidences on the roles of RP membrane proteins in NRB. Natural rubber is stored in rubber particle from the rubber tree. Rubber particles were traditionally purified by repeated washing, but many proteins were identified from the washing solutions (WS). We obtained the first visualization proteome profiles with 1825 proteins from WS, including 246 WS-specific ones. These WS proteins contain almost all enzymes for polyisoprene initiation and may play important roles in rubber biosynthesis. Copyright © 2018 Elsevier B.V. All rights reserved.
The water-food nexus of natural rubber production
NASA Astrophysics Data System (ADS)
Chiarelli, D. D.; Rosa, L.; Rulli, M. C.; D'Odorico, P.
2017-12-01
The increasing global demand for natural rubber (100% increase in the last 15 years) is for most part met by Malaysia and Indonesia, and - to a lesser extent - other countries in south-east Asia and Africa. The consequent expansion of rubber plantation has often occurred at the expenses of agricultural land for staple food, particularly in southeast Asia, where most of the land suitable for agriculture is already harvested for food crops or other uses. Here we investigate the extent to which the ongoing increase in rubber production is competing with the food system and affecting the livelihoods of rural communities in the areas of production and their appropriation of natural resources, such as water. We also investigate to what extent the expansion of rubber plantations is taking place through large scale land acquisitions (LSLAs) and evaluate the impacts on rural communities. Our results show how rubber production has strong environmental, social and economic impacts. Despite their ability to bring employment and increase the average income of economically disadvantaged areas, rubber plantations may threaten the local water and food security and induce a loss of rural livelihoods, particularly when the new plantations result from LSLAs that displace semi-subsistence forms of production thereby forcing the local populations to depend on global markets.
Analysis of Human-Spacesuit Interaction
NASA Technical Reports Server (NTRS)
Thomas, Neha
2015-01-01
Astronauts sustain injuries of various natures such as finger delamination, joint pain, and redness due to their interaction with the space suit. The role of the Anthropometry and Biomechanics Facility is to understand the biomechanics, environmental variables, and ergonomics of the suit. This knowledge is then used to make suggestions for improvement in future iterations of the space suit assembly to prevent injuries while allowing astronauts maneuverability, comfort, and tactility. The projects I was involved in were the Extravehicular Mobility Unit (EMU) space suit stiffness study and the glove feasibility study. The EMU project looked at the forces exerted on the shoulder, arm, and wrist when subjects performed kinematic tasks with and without a pressurized suit. The glove study consisted of testing three conditions - the Series 4000 glove, the Phase VI glove, and the no glove condition. With more than forty channels of sensor data total, it was critical to develop programs that could analyze data with basic descriptive statistics and generate relevant graphs to help understand what happens within the space suit and glove. In my project I created a Graphical User Interface (GUI) in MATLAB that would help me visualize what each sensor was doing within a task. The GUI is capable of displaying overlain plots and can be synchronized with video. This was helpful during the stiffness testing to visualize how the forces on the arm acted while the subject performed tasks such as shoulder adduction/abduction and bicep curls. The main project of focus, however, was the glove comparison study. I wrote MATLAB programs which generated movies of the strain vectors during specific tasks. I also generated graphs that summarized the differences between each glove for the strain, shear and FSR sensors. Preliminary results indicate that the Phase VI glove places less strain and shear on the hand. Future work includes continued data analysis of surveys and sensor data. In the end, the ideal glove is one that provides more tactility for the astronauts but lessens injuries. Often times, a more tactile glove transmits forces better to the hand; thus, achieving a balance of both a tactile and safe glove is the main challenge present.
Detection and toxicity assessment of nitrosamines migration from latex gloves in the Chinese market.
Feng, Di; Wang, Huiping; Cheng, Xuelian; Wang, Jiedong; Ning, Lifeng; Zhou, Qingfeng; Zhou, Yue; Yang, Quanli
2009-09-01
Nitrosamines are potent carcinogens and have been found in latex products. In 2007, twenty-seven natural latex gloves including sterile gloves, examination gloves and household use gloves were sampled from the Chinese market. This study monitored the migration of nitrosamines and nitrosatable substance from these gloves, and evaluated their mutagenicity using a Salmonella typhimurium mutation assay (Ames assay) with the strains TA98, TA97, TA100 and TA102 and by a micronucleus test (MN test) using ICR mice. In addition, the cytotoxicity of these compounds was determined by a MTT assay. N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA) and N-nitrosodibutylamine (NDBA) were all found in samples treated with artificial sweat for 4h at 37 degrees C, and total nitrosamines varied from 18.89 to 244.51microg/Kg. The nitrosamine mixture of NDMA, NDEA and NDBA was used in both the Ames assay and the MN test. The proportion of NDMA, NDEA and NDBA (1:10:20) was selected according to the proportion of nitrosamines migration from sample E05. In the Ames assay, the lowest dose (1.98 x 10(-3)microg per plate) produced a positive result in the TA98 strain, corresponding to nitrosamines migration from sample E05 of 0.016g (the total nitrosamines migration from glove E05 was 122.55 microg/kg). The TA100 strain responded positively at a dose of 4.96 x 10(-2)microg per plate, corresponding to nitrosamines migration from glove E05 of 0.040g. The MN test showed nitrosamine migration of 3.04 mg from 2066 pairs of sample E05 and could induce micronuclei in one mouse weighing 28g (average weight of one E05 glove was 6g). Extracts from gloves were found to be cytotoxic and there was a significant correlation between cytotoxicity (IC50) and the release level of nitrosamines. In conclusion, in view of the high content of nitrosamines in latex gloves and the potential toxicity of nitrosamines migration from these gloves, it is suggested that both an effective and feasible detection method and prescribed limits should be imposed.
Stelescu, Maria-Daniela; Craciun, Gabriela; Dumitrascu, Maria
2014-01-01
A new polymeric composite based on natural rubber reinforced with hemp has been processed by electron beam irradiation and characterized by several methods. The mechanical characteristics: gel fraction, crosslink density, water uptake, swelling parameters, and FTIR of natural rubber/hemp fiber composites have been investigated as a function of the hemp content and absorbed dose. Physical and mechanical properties present a significant improvement as a result of adding hemp fibres in blends. Our experiments showed that the hemp fibers have a reinforcing effect on natural rubber similar to mineral fillers (chalk, carbon black, silica). The crosslinking rates of samples, measured using the Flory-Rehner equation, increase as a result of the amount of hemp in blends and the electron beam irradiation dose increasing. The swelling parameters of samples significantly depend on the amount of hemp in blends, because the latter have hydrophilic characteristics. PMID:24688419
Stelescu, Maria-Daniela; Manaila, Elena; Craciun, Gabriela; Dumitrascu, Maria
2014-01-01
A new polymeric composite based on natural rubber reinforced with hemp has been processed by electron beam irradiation and characterized by several methods. The mechanical characteristics: gel fraction, crosslink density, water uptake, swelling parameters, and FTIR of natural rubber/hemp fiber composites have been investigated as a function of the hemp content and absorbed dose. Physical and mechanical properties present a significant improvement as a result of adding hemp fibres in blends. Our experiments showed that the hemp fibers have a reinforcing effect on natural rubber similar to mineral fillers (chalk, carbon black, silica). The crosslinking rates of samples, measured using the Flory-Rehner equation, increase as a result of the amount of hemp in blends and the electron beam irradiation dose increasing. The swelling parameters of samples significantly depend on the amount of hemp in blends, because the latter have hydrophilic characteristics.
NASA Astrophysics Data System (ADS)
Xu, Tiwen; Jia, Zhixin; Luo, Yuanfang; Jia, Demin; Peng, Zheng
2015-02-01
The epoxidized natural rubber (ENR) as an interfacial modifier was used to improve the mechanical and dynamical mechanical properties of NR/silica composites. In order to reveal the interaction mechanism between ENR and silica, the ENR/Silica model compound was prepared by using an open mill and the interfacial interaction of ENR with silica was investigated by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), X-ray diffraction (XRD) and stress-strain testing. The results indicated that the ring-opening reaction occurs between the epoxy groups of ENR chains and Si-OH groups on the silica surfaces and the covalent bonds are formed between two phases, which can improve the dispersion of silica in the rubber matrix and enhance the interfacial combination between rubber and silica. The ring-opening reaction occurs not only in vulcanization process but also in mixing process, meanwhile, the latter seems to be more important due to the simultaneous effects of mechanical force and temperature.
Image Classification of Ribbed Smoked Sheet using Learning Vector Quantization
NASA Astrophysics Data System (ADS)
Rahmat, R. F.; Pulungan, A. F.; Faza, S.; Budiarto, R.
2017-01-01
Natural rubber is an important export commodity in Indonesia, which can be a major contributor to national economic development. One type of rubber used as rubber material exports is Ribbed Smoked Sheet (RSS). The quantity of RSS exports depends on the quality of RSS. RSS rubber quality has been assigned in SNI 06-001-1987 and the International Standards of Quality and Packing for Natural Rubber Grades (The Green Book). The determination of RSS quality is also known as the sorting process. In the rubber factones, the sorting process is still done manually by looking and detecting at the levels of air bubbles on the surface of the rubber sheet by naked eyes so that the result is subjective and not so good. Therefore, a method is required to classify RSS rubber automatically and precisely. We propose some image processing techniques for the pre-processing, zoning method for feature extraction and Learning Vector Quantization (LVQ) method for classifying RSS rubber into two grades, namely RSS1 and RSS3. We used 120 RSS images as training dataset and 60 RSS images as testing dataset. The result shows that our proposed method can give 89% of accuracy and the best perform epoch is in the fifteenth epoch.
Toxicity of Pyrolysis Gases from Elastomers
NASA Technical Reports Server (NTRS)
Hilado, Carlos J.; Kosola, Kay L.; Solis, Alida N.; Kourtides, Demetrius A.; Parker, John A.
1977-01-01
The toxicity of the pyrolysis gases from six elastomers was investigated. The elastomers were polyisoprene (natural rubber), styrene-butadiene rubber (SBR), ethylene propylene diene terpolymer (EPDM), acrylonitrile rubber, chlorosulfonated polyethylene rubber, and polychloroprene. The rising temperature and fixed temperature programs produced exactly the same rank order of materials based on time to death. Acryltonitrile rubber exhibited the greatest toxicity under these test conditions; carbon monoxide was not found in sufficient concentrations to be the primary cause of death.
USDA-ARS?s Scientific Manuscript database
Hydrolytic enzymes from a newly isolated strain of the thermophilic fungus Thermomyces lanuginosus were used to extract rubber from Taraxacum kok-saghyz commonly known as rubber (or Russian or Kazak(h)) dandelion. The fungus was isolated from garden soil and identified as Thermomyces lanuginosus STm...
Preparation of sulfonic acid-containing rubbers from natural rubber vulcanizates
NASA Astrophysics Data System (ADS)
Poonsawat, Worapong; Poompradub, Sirilux; Ngamcharussrivichai, Chawalit
2014-06-01
In this work, a series of sulfonic acid-containing rubbers were prepared by aqueous phase oxidation of natural rubber vulcanizates in the presence of hydrogen peroxide (H2O2) and formic acid (HCOOH). The starting vulcanizates were neatly prepared via an efficient vulcanization (EV) system by varying mass ratio of N-cyclohexyl-2-benzothiazole sulfonamide (CBS), as an accelerator, to sulfur. The oxidation conditions were controlled at the molar ratio of H2O2: HCOOH = 1:1, the concentration of H2O2 = 15 wt.%, the temperature = 50 °C, and the reaction time = 3 h. The rubber materials before and after the oxidation were characterized for their physicochemical properties by using Fourier transform infrared spectroscopy, bomb calorimetry, acid-base titration and swelling measurements. The results indicated the presence of sulfonic acid group in the oxidized rubbers, generated by the oxidative cleaves of sulfide crosslinks in the rubber vulcanizates. The oxidation decreased the sulfur content of the rubber in which the level of sulfur loss was determined by the CBS/sulfur ratio. Moreover, the acidity of the oxidized products was correlated with the amount of sulfur remaining.
Compliance of Saudi dental students with infection control guidelines.
Ahmad, Ibrahim Ali; Rehan, Elaf Ali; Pani, Sharat Chandra
2013-08-01
The aim of this study was to investigate compliance of dental students in a Saudi dental school with recommended infection control protocols. A pilot-tested questionnaire concerning various aspects of infection control practices was distributed to 330 dental students. The response rate was 93.9% (n = 311). About 99% of students recorded the medical history of their patients and 80% were vaccinated against hepatitis B. The highest compliance (100%) with recommended guidelines was reported for wearing gloves and use of a new saliva ejector for each patient. Over 90% of the respondents changed gloves between patients, wore face masks, changed hand instruments, burs and handpieces between patients, used a rubber dam in restorative procedures and discarded sharp objects in special containers. A lower usage rate was reported for changing face masks between patients (81%), disinfecting impression materials (87%) and dental prosthesis (74%) and wearing gowns (57%). Eye glasses and face shield were used by less than one-third of the sample. The majority of students were found to be in compliance with most of the investigated infection control measures. Nevertheless, further education is needed to improve some infection control measures including vaccination for Hepatitis B virus (HBV), wearing eye glasses, gowns and face shields and disinfecting impression materials and dental prostheses. © 2013 FDI World Dental Federation.
Li, Huan; Sinha, Tridib K; Oh, Jeong Seok; Kim, Jin Kuk
2018-04-25
Inspired by the epidermis-dermis composition of human skin, here we have simply developed a lightweight, robust, flexible, and biocompatible single-electrode triboelectric nanogenerator (S-TENG)-based prototype of bilayer artificial skin, by attaching one induction electrode with unfoamed skin layer of microcellular thermoplastic polyurethane (TPU) foam, which shows high-performance object manipulation [by responding differently toward different objects, viz., aluminum foil, balloon, cotton glove, human finger, glass, rubber glove, artificial leather, polyimide, poly(tetrafluoroethylene) (PTFE), paper, and wood], due to electrification and electrostatic induction during contact with the objects having different chemical functionalities. Comparative foaming behavior of ecofriendly supercritical fluids, viz., CO 2 over N 2 under variable temperatures (e.g., 130 and 150 °C) and constant pressure (15 MPa), have been examined here to pursue the soft and flexible triboelectric TPU foam. The foam derived by CO 2 foaming at 150 °C has been prioritized for development of S-TENG. Foam derived by CO 2 foaming at 130 °C did not respond as well due to the smaller cell size, higher hardness, and thicker skin. Inflexible N 2 -derived foam was not considered for S-TENG fabrication. Object manipulation performance has been visualized by principal component analysis (PCA), which shows good discrimination among responses to different objects.
Combination biological and microwave treatments of used rubber products
Fliermans, Carl B.; Wicks, George G.
2002-01-01
A process and resulting product is provided in which a vulcanized solid particulate, such as vulcanized crumb rubber, has select chemical bonds altered by biotreatment with thermophillic microorganisms selected from natural isolates from hot sulfur springs. Following the biotreatment, microwave radiation is used to further treat the surface and to treat the bulk interior of the crumb rubber. The resulting combined treatments render the treated crumb rubber more suitable for use in new rubber formulations. As a result, larger loading levels and sizes of the treated crumb rubber can be used in new rubber mixtures and good properties obtained from the new recycled products.
Advances in rubber/halloysite nanotubes nanocomposites.
Jia, Zhixin; Guo, Baochun; Jia, Demin
2014-02-01
The research advances in rubber/halloysite nanotubes (rubber/HNTs) nanocomposites are reviewed. HNTs are environmentally-friendly natural nanomaterials, which could be used to prepare the rubber-based nanocomposites with high performance and low cost. Unmodified HNTs could be adopted to prepare the rubber/HNTs composites with improved mechanical properties, however, the rubber/HNTs nanocomposites with fine morphology and excellent properties were chiefly prepared with various modifiers by in situ mixing method. A series of rubber/HNTs nanocomposites containing several rubbers (SBR, NR, xSBR, NBR, PU) and different modifiers (ENR, RH, Si69, SA, MAA, ILs) have been investigated. The results showed that all the rubber/HNTs nanocomposites achieved strong interfacial interaction via interfacial covalent bonds, hydrogen bonds or multiple interactions, realized significantly improved dispersion of HNTs at nanoscale and exhibited excellent mechanical performances and other properties.
NASA Astrophysics Data System (ADS)
Ahmad, N.; Dayana, S. A. S.; Abnisa, F.; Mohd, W. A. W. D.
2018-03-01
Natural rubber is a humid agricultural harvest, which mostly contains hydrocarbon cis-1, 4-Poly isoprene. Through depolymerisation technology, the natural rubber can be changed into liquid product, and then it can be subsequently utilized as a fuel or chemical feedstock. This article aims to provide an outlook on the natural rubber and its sources, which are available globally. Numerous depolymerisation processes, which include pyrolysis, gasification, chemical degradation, catalytic cracking and hydrogenation, were introduced in this paper, while the focus of discussion was emphasized on the hydrous pyrolysis process. Many studies have shown that the use of hydrous pyrolysis able to improve the depolymerisation process, e.g. the raw material can be feed without drying, the process can be carried out at lower temperature, only the water is used as the reaction medium, and it is easy to separate the water from oil product. The effect of operating parameters such as temperature, water to rubber mass ratio, reaction time and type of gases on the product yield and composition were reviewed in this paper. In addition, this paper also highlighted the eco-friendly and economic viability of the hydrous pyrolysis process.
Effect of electron beam irradiation on the properties of crosslinked rubbers
NASA Astrophysics Data System (ADS)
Banik, Indranil; Bhowmick, Anil K.
2000-05-01
Influence of electron beam (EB) irradiation on the mechanical and dynamic mechanical properties of crosslinked fluorocarbon (FKM) rubber, natural rubber (NR), ethylene propylene diene monomer (EPDM) rubber and nitrile rubber (NBR) has been investigated. The modulus, gel fraction, glass transition temperature ( Tg) and storage modulus increased, while the elongation at the break and the loss tangent (tan δ) Tg decreased. FKM and NBR vulcanizates have been shown to have EB radiation resistance up to 1500 kGy.
Flooded Cell Permeation Testing of Elastomers
1994-03-01
cured hydrin (EC) elastomer 3. oxide cured neoprene (CR) 4. sulphur cured styrene-butadiene rubber (SBR) 5. sulphur cured nitrile rubber ( NBR ) 6. cured...Road Adelphi, MD 20783-1197 11. SUPPLEMENTARY NOTES Presented at the meeting of the American Chemical Society, Rubber Division, Orlando, Florida, 26 Oct...6 2. Permeation rate-time curve for DMSO through natural rubber ............................... 6 3. Permeation rate-time curve for DMSO through
The use of smoke acid as an alternative coagulating agent for natural rubber sheets' production.
Ferreira, Vanda S; Rêgo, Ione N C; Pastore, Floriano; Mandai, Mariana M; Mendes, Leonardo S; Santos, Karin A M; Rubim, Joel C; Suarez, Paulo A Z
2005-03-01
A comparative study of rubber sheets obtained using formic, acetic, and smoke acid as coagulants is shown for latex obtained from native Amazonian trees and also from commercial cultivated trees. The evaluation of both processes of coagulation was carried out by spectroscopic and physical-chemical analysis, showing no differences in the rubber sheets obtained. This new method of rubber sheet preparation was introduced into Amazonian rainforest rubber tapper communities, which are actually producing in large scale. The physical-mechanical properties were similar among a large sheets made by different rubber tapper communities using this new method.
NASA Astrophysics Data System (ADS)
Harahap, Hamidah; Hayat, Nuim; Lubis, Marfuah
2017-07-01
Sugarcane waste is abundant sources of cellulose and it has potential to reutilize. Cellulose from sugarcane waste can be derived into nanocystalline cellulose (NCC) from crystalline region. The NCC as a filler has capability to reinforce natural rubber latex product. The crosslink in vulcanized natural rubber latex film influences several properties of product. In this work, we extracted NCC from sugarcane waste then added into natural rubber latex as filler modified alkanolamide (ALK) and also studied the crosslink of natural rubber latex films. NCC were produced from sugarcane waste by hydrolysis process with sulfuric acid 45%. The obtained NCC was characterized by using x-ray diffraction (XRD), transmission electron microscopy (TEM), and fourier transform infra red (FTIR). NCC was modified by alkanolamide and dispersed in water with filler concentration of 10%. Then the dispersion were added into latex system followed by pre-vulcanization at 70 °C. The films were prepared by coagulant dipping method and dried at 100 °C and 120 °C for 20 minutes. Characterization of NCC from sugarcane waste by using FTIR was done, it clearly showed the functional groups of cellulose. TEM showed the obtained NCC were rod-shaped with about 40-160 nm in diameter and several hundred nm in length, and XRD showed that the degree of crystalinity of NCC from sugarcane waste is 92.33%. The crosslink of natural rubber films were studied by measure the crosslink density for different filler loading by using swelling measurement with toluene solution. The result show that the crosslink density increased in line with amount of filler which added into the system, and also the crosslink density that obtained from vulcanization at 120 °C were higher than 100 °C.
2015-06-01
methylphosphonothiolate (VX) through natural latex rubber and neoprene resulting from LVAP tests. 2. The permeation model is used to study the sensitivity of...Styrene–Butadiene– Rubber , Ethylene–Propylene–Diene Terpolymer, and Natural Rubber Versus Hydrocarbons (C8–C16). Macromolecules 1991, 24 (9), 2598–2605...22 14. Harogoppad, S.B.; Aminabhavi, T.M. Diffusion and Sorption of Organic Liquids through Polymer Membranes 2. Neoprene, SBR, EPDM , NBR, and
Evaluation of a Lightweight Protective Mask Concept for Respiratory Protection System 21
1992-01-01
In addition, the LPM should provide a comfortable fit to reduce the physiological burden on the solder. The M40 mask is molded of silicone rubber ...for low temperature flexibility and romfort even though this material doesn’t providr. a good chemical agent barrier. Also, the M40 uses thick rubber ...Latex BL-100 (Appeadix D, no. 32) with natural rubber latex 1041, (Firestone), and by evenly mixing polyisobutylene latem I (PIB-5C) with natural
Nanocomposites of natural rubber and polyaniline-modified cellulose nanofibrils
USDA-ARS?s Scientific Manuscript database
Cellulose nanofibrils (CNF) were isolated from cotton microfibrils (CM) by acid hydrolysis and coated with polyaniline (PANI) by in situ polymerization of aniline onto CNF in the presence of hydrochloride acid and ammonium peroxydisulfate to produce CNF/PANI. Nanocomposites of natural rubber (NR) re...
Design of virtual three-dimensional instruments for sound control
NASA Astrophysics Data System (ADS)
Mulder, Axel Gezienus Elith
An environment for designing virtual instruments with 3D geometry has been prototyped and applied to real-time sound control and design. It enables a sound artist, musical performer or composer to design an instrument according to preferred or required gestural and musical constraints instead of constraints based only on physical laws as they apply to an instrument with a particular geometry. Sounds can be created, edited or performed in real-time by changing parameters like position, orientation and shape of a virtual 3D input device. The virtual instrument can only be perceived through a visualization and acoustic representation, or sonification, of the control surface. No haptic representation is available. This environment was implemented using CyberGloves, Polhemus sensors, an SGI Onyx and by extending a real- time, visual programming language called Max/FTS, which was originally designed for sound synthesis. The extension involves software objects that interface the sensors and software objects that compute human movement and virtual object features. Two pilot studies have been performed, involving virtual input devices with the behaviours of a rubber balloon and a rubber sheet for the control of sound spatialization and timbre parameters. Both manipulation and sonification methods affect the naturalness of the interaction. Informal evaluation showed that a sonification inspired by the physical world appears natural and effective. More research is required for a natural sonification of virtual input device features such as shape, taking into account possible co- articulation of these features. While both hands can be used for manipulation, left-hand-only interaction with a virtual instrument may be a useful replacement for and extension of the standard keyboard modulation wheel. More research is needed to identify and apply manipulation pragmatics and movement features, and to investigate how they are co-articulated, in the mapping of virtual object parameters. While the virtual instruments can be adapted to exploit many manipulation gestures, further work is required to reduce the need for technical expertise to realize adaptations. Better virtual object simulation techniques and faster sensor data acquisition will improve the performance of virtual instruments. The design environment which has been developed should prove useful as a (musical) instrument prototyping tool and as a tool for researching the optimal adaptation of machines to humans.
USDA-ARS?s Scientific Manuscript database
Biobased rubber composites are renewable and sustainable. Significant improvement in modulus of rubber composite reinforced with hydrophilic filler was achieved with the inclusion of ionomers. Soy particles aided with ionomer, carboxylated styrene-butadiene (CSB), formed a strong complex filler netw...
Mechanical and morphological properties of kenaf powder filled natural rubber latex foam
NASA Astrophysics Data System (ADS)
Karim, Ahmad Fikri Abdul; Ismail, Hanafi; Ariff, Zulkifli Mohamad
2015-07-01
This research is carried out by incorporate kenaf powder with natural rubber latex (NRL) compound and is foamed to make natural rubber latex foam (NRLF) by using a well known technique called Dunlop method. Different loading of kenaf powder was added to NRL compound and was foamed to make NRLF. The tensile properties, and morphology of kenaf filled NRLF was studied. Increase in kenaf loading reduced the tensile strength and elongation at break and of a compound. Modulus at 100% elongation of the compound increased with increased in filler loading. The morphological and micro structural characterization has been performed by using scanning electron microscopy (SEM).
Improvement of Mechanical Properties in Natural Rubber with Organic Fillers
NASA Astrophysics Data System (ADS)
Gonzales-Fernandes, M.; Bastos, Andrade C. G.; Esper, F. J.; Valenzuela-Diaz, F. R.; Wiebeck, H.
When added to polymeric matrices, organophilic clay transforms the performance of the resulting composites. A natural rubber matrix with different loads was prepared as bentonite chocolate B modified by sodification and treated with ammonium quaternary salt with cellulose charge, cardboard and palm fiber. After the mixture of natural rubber in a roller mill with the additives and subsequent addition of loads individually, plates were vulcanized for fabricating specimens. We measured the mechanical properties of traction and the interlayer distances analyzed by XRD. The aim of the paper is to show that the composite obtained improved in mechanical properties as compared to plates without the addition of loads.
Ultra-Low Permeability Polymeric Encapsulants for Acoustic Applications
2006-05-10
polyurethane, tend to exhibit greater water permeability than those that are vulcanizates, such as butyl rubber, EPDM (ethylene propylene diene monomer) rubber...water permeation is a critical concern, hydrophobic, non-polar polymers such as EPDM and butyl rubber are typically used. These materials are vulcanizates...Their non-polar nature makes it difficult to bond anything else strongly to them. Thus, most EPDM and butyl rubber boots are secured to the underlying
Protein influences on guayule and Hevea natural rubber sol and gel
USDA-ARS?s Scientific Manuscript database
Guayule (Parthenium argentatum) is under cultivation in the southwestern United States as an alternative source of natural rubber free from proteins that cause Type I latex allergies. However, since guayule lacks the protein-polymer interactions present in Hevea latex, its physical and chemical prop...
Studies of the latex of Brazilian IAC series clones from Hevea brasiliensis
USDA-ARS?s Scientific Manuscript database
Natural rubber is an important commodity industrial crop that mainly derives from Hevea brasiliensis. Most natural rubber production is in Southeast Asia, but significant cultivar development takes place in Brazil, the original origin of current commercial H. brasiliensis cultivars. Thus it is criti...
NASA Astrophysics Data System (ADS)
Siti Nor Qamarina, M.; Fatimah Rubaizah, M. R.; Nurul Suhaira, A.; Norhanifah, M. Y.
2017-12-01
Epoxidized natural rubber latex (ENRL) is a chemically modified natural rubber latex produced from epoxidation process that involves usage of organic peracids. Conversion of the ENRL into dry rubber products has been known to exhibit many beneficial properties, however limited published works were found on diversifiying the ENRL latex-based products applications. In this preliminary work, different source of raw materials and neutralization systems were investigated. The objective was to explore possibilities in producing distinctive ENRL. Findings have demonstrated that different source of raw materials and neutralization systems influenced the typical ENRL specifications, stability behavior and particle size distribution. Morphological observations performed on these ENRL systems appeared to agree with the ENRL characteristics achieved. Since experimenting these two main factors resulted in encouraging ENRL findings, detailed work shall be further scrutinized to search for an optimum condition in producing marketable ENRL specifically for latex-based products applications.
NASA Astrophysics Data System (ADS)
Suratman, Mohd Nazip
2003-06-01
Rubber tree (Hevea brasiliensis (Wild ex Adr. De Juss) Muell Arg.) plantations in Malaysia are important sources of natural rubber and wood products. Effective management and appropriate policy for these resources require reliable information on resource dynamics and forecasts of resource availability. The need for inventories and monitoring systems prompted this research into utilising ground information and satellite imagery for developing methods for forest plantation inventory. Monitoring procedures were developed using three dates of Landsat Thematic Mapper (TM) imagery. The specific objectives of the research were: (1) to develop an effective method for inventorying rubber tree plantations using an appropriate combination of satellite imagery and ground sampling in the State of Selangor, Malaysia; (2) to demonstrate the application of a Landsat TM-based rubber volume model in an extended area of rubber plantations south of Kuala Lumpur (KL), Malaysia; (3) to develop an operational methodology for monitoring land use/cover change, with a primary focus on rubber plantations; and (4) to identify relationships between the primary drivers of resource change and policies, and examine the evidence of policies---rubber area change linkages in the study area. Reasonably accurate predictions of the volume, age, and area of rubber plantations were obtained from Landsat TM data. The use of supervised image classification and an image segmentation approach for rubber volume model application showed better performance for volume prediction than a combined land use/cover and rubber volume classification technique, thus providing a useful tool for displaying rubber stand volume within segments or spatial units across the landscape. The combined use of a time series of Landsat TM imagery, modified postclassification change detection, and geographic information system (GIS) techniques made it possible to produce land use/cover change matrices and rubber area change information, thus helping to understand the dynamics of the rubber tree resource. The decrease in the area of rubber plantations and the increase in the area of mixed crops from 1989--1993 in south of KL were partly attributed to the adoption of a crop diversification policy which was driven by relatively poor natural rubber prices during that time. The decrease in the areas of rubber plantations from 1993--1999 in this area was primarily due to rapid urbanization and infrastructure development driven by demographic expansion in the area south of KL. This thesis makes a practical contribution to the development of methods for inventory of forest plantations by linking ground information with model projections based on satellite data. Additionally, the thesis demonstrates the development of monitoring tools to assess resource availability and variability over time, and establish its linkages to policies. The inventory information, models, and monitoring protocols are needed for effective resource management planning aimed at maximizing the potential benefits of rubber tree crops for wood and natural rubber supply in Malaysia.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-11
... Product Container Is Not Made With Natural Rubber Latex.'' The purpose of this draft guidance is to make recommendations on the appropriate language to include in the labeling of a medical product to convey that natural... Products To Inform Users That the Product or Product Container Is Not Made With Natural Rubber Latex...
NASA Astrophysics Data System (ADS)
Mohamed, R.; Nurazzi, N. Mohd; Huzaifah, M.
2017-07-01
This study was conducted to investigate the possibility of utilizing sludge palm oil (SPO) as processing oil, with various amount of carbon black as its reinforcing filler, and its effects on the curing characteristics and mechanical properties of natural rubber/styrene butadiene rubber (NR/SBR) compound. Rubber compound with fixed 15 pphr of SPO loading, and different carbon black loading from 20 to 50 pphr, was prepared using two roll mills. The cure characteristics and mechanical tests that have been conducted are the scorch and cure time analysis, tensile strength and tear strength. Scorch time (ts5) and cure time (t90) of the compound increases with the increasing carbon black loading. The mechanical properties of NR/SBR compound viz. the tensile strength, modulus at 300% strain and tear strength were also improved by the increasing carbon black loading.
Task 3 - Pyrolysis of Plastic Waste. Semiannual report, November 1, 1996--March 31, 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ness, Robert O.; Aulich, Ted R.
1997-12-31
Over the last 50 years, the U.S. Department of Energy (DOE) has produced a wide variety of radioactive wastes from activities associated with nuclear defense and nuclear power generation. These wastes include low-level radioactive solid wastes, mixed wastes, and transuranic (TRU) wastes. A portion of these wastes consists of high- organic-content materials, such as resins, plastics, and other polymers; synthetic and natural rubbers; cellulosic-based materials; and oils, organic solvents, and chlorinated organic solvents. Many of these wastes contain hazardous and/or pyrophoric materials in addition to radioactive species. Physical forms of the waste include ion-exchange resins used to remove radioactive elementsmore » from nuclear reactor cooling water, lab equipment and tools (e.g., measurement and containment vessels, hoses, wrappings, equipment coverings and components, and countertops), oil products (e.g., vacuum pump and lubrication oils), bags and other storage containers (for liquids, solids, and gases), solvents, gloves, lab coats and anti-contamination clothing, and other items. Major polymer and chemical groups found in high-organic-content radioactive wastes include polyvinyl chloride (PVC), low-density polyethylene (LDPE), polypropylene (PP), Teflon(TM), polystyrene (PS), nylon, latex, polyethylene terephthalate (PET), vinyl, high-density polyethylene (HDPE), polycarbonate, nitriles, Tygon(R), butyl, and Tyvec(R).« less
Effect of heating rate on toxicity of pyrolysis gases from some elastomers
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Kosola, K. L.; Solis, A. N.
1977-01-01
The effect of heating rate on the toxicity of the pyrolysis gases from six elastomers was investigated, using a screening test method. The elastomers were polyisoprene (natural rubber), styrene-butadiene rubber (SBR), ethylene propylene diene terpolymer (EPDM), acrylonitrile rubber, chlorosulfonated polyethylene rubber, and polychloroprene. The rising temperature and fixed temperature programs produced exactly the same rank order of materials based on time to death. Acrylonitrile rubber exhibited the greatest toxicity under these test conditions, and carbon monoxide was not found in sufficient concentrations to be the primary cause of death.
RADIOPATHIES IN THE HAND OF THE SURGEON
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marino, H.
1962-03-01
Several cases are described in which severe radiation injuries occurred in the hands of surgeons during operative procedures requiring fluoroscopy. The radiation lesions appeared to be aggravated by the various mechanical traumas accompanying washing-up processes preceding surgery including brushing the fingers, use of strong disinfectants and detergents, and sprinkling the hands with talcum before donning rubber gloves. These routine measures may cause acute eruptions of old radiation lesions. Various phases in the development of radiation burns on the hands, from the initial dermatitis to the late necrotic changes, are discussed. Fraquently, the early lesions are erroneously diagnosed as allergic eczemamore » so that effective therapeutic measures may not be instituted soon enough. Plastic surgical rapairs of finger lesions, in the cases described, are illustrated. (H.H.D.)« less
Calcium media improves regeneration of guayule
USDA-ARS?s Scientific Manuscript database
Natural rubber is one of the largest agricultural exports in the world, valued at over $33 billion in 2011 (faostat.fao.org). A 20-30% increase in demand for natural rubber is expected over the next 10 years, driven mainly by rapid economic growth in China & India. Development of additional sources ...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2014 CFR
2014-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2011 CFR
2011-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2013 CFR
2013-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2012 CFR
2012-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2010 CFR
2010-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
Tongrod, Nattapong; Lokavee, Shongpun; Watthanawisuth, Natthapol; Tuantranont, Adisorn; Kerdcharoen, Teerakiat
2013-03-01
Current trends in Human-Computer Interface (HCI) have brought on a wave of new consumer devices that can track the motion of our hands. These devices have enabled more natural interfaces with computer applications. Data gloves are commonly used as input devices, equipped with sensors that detect the movements of hands and communication unit that interfaces those movements with a computer. Unfortunately, the high cost of sensor technology inevitably puts some burden to most general users. In this research, we have proposed a low-cost data glove concept based on printed polymeric sensor to make pressure and bending sensors fabricated by a consumer ink-jet printer. These sensors were realized using a conductive polymer (poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) [PEDOT:PSS]) thin film printed on glossy photo paper. Performance of these sensors can be enhanced by addition of dimethyl sulfoxide (DMSO) into the aqueous dispersion of PEDOT:PSS. The concept of surface resistance was successfully adopted for the design and fabrication of sensors. To demonstrate the printed sensors, we constructed a data glove using such sensors and developed software for real time hand tracking. Wireless networks based on low-cost Zigbee technology were used to transfer data from the glove to a computer. To our knowledge, this is the first report on low cost data glove based on paper pressure sensors. This low cost implementation of both sensors and communication network as proposed in this paper should pave the way toward a widespread implementation of data glove for real-time hand tracking applications.
Slip resistant properties of footwear on ice.
Gao, Chuansi; Abeysekera, John; Hirvonen, Mikko; Grönqvist, Raoul
2004-05-15
Current research on slipperiness of footwear has mainly focused on floors and lubricated floors. Slips and falls on icy and snowy surfaces involve not only outdoor workers, but also pedestrians and the general public; and occur in cold regions and in winter season in many parts of the world. However, in comparison with the size of the problem, research on slips and falls on icy and snowy surfaces has been scarce. The objective of this paper is to explore the slip resistant properties of footwear (soling materials, roughness and hardness) on ice. The coefficients of kinetic friction of four different soling materials (synthetic rubber, nitrile rubber, natural rubber and polyurethane) were measured on ice (-12 degrees C). The outsole roughness and hardness were also measured. Results showed that the polyurethane soling did not perform better than synthetic rubber, nitrile rubber and natural rubber on pure hard ice (-12 degrees C). Soling roughness was positively correlated with the coefficient of kinetic friction. The most slip resistant soling material (polyurethane) on floors and lubricated floors may not provide sufficient slip resistance on ice.
Wettability of naturally aged silicone and EPDM composite insulators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gubanski, S.M.; Vlastos, A.E.
1990-07-01
This paper reports the wettability of aged surfaces and of the bulk of naturally aged silicone and EPDM insulator housings and of silicone elastomer insulator coatings studied. The samples were taken either directly from the insulators or treated by exposing them to corona discharges and/or to saline pollution. The results show that the contact angles of the silicone rubber insulator surfaces are larger than the contact angles of the RTV silicone rubber coating and of the EPDM rubber insulator surfaces, especially when the surfaces are aged. When the insulators were exposed to corona discharges, the contact angles of the siliconemore » rubber insulators are reduced but after the exposure they recover with time. The contact angles of the EPDM rubber insulators, however, after the exposure, continue to reduce. When exposed to artificial saline pollution, the silicone rubber insulators show a limited recovery of their contact angles with time, while, when exposed to corona discharge, they show a recovery of the contact angle after the exposure. The time for recovery is dependent on the exposure time to the corona discharges.« less
Large-scale collection of full-length cDNA and transcriptome analysis in Hevea brasiliensis
Makita, Yuko; Ng, Kiaw Kiaw; Veera Singham, G.; Kawashima, Mika; Hirakawa, Hideki; Sato, Shusei
2017-01-01
Abstract Natural rubber has unique physical properties that cannot be replaced by products from other latex-producing plants or petrochemically produced synthetic rubbers. Rubber from Hevea brasiliensis is the main commercial source for this natural rubber that has a cis-polyisoprene configuration. For sustainable production of enough rubber to meet demand elucidation of the molecular mechanisms involved in the production of latex is vital. To this end, we firstly constructed rubber full-length cDNA libraries of RRIM 600 cultivar and sequenced around 20,000 clones by the Sanger method and over 15,000 contigs by Illumina sequencer. With these data, we updated around 5,500 gene structures and newly annotated around 9,500 transcription start sites. Second, to elucidate the rubber biosynthetic pathways and their transcriptional regulation, we carried out tissue- and cultivar-specific RNA-Seq analysis. By using our recently published genome sequence, we confirmed the expression patterns of the rubber biosynthetic genes. Our data suggest that the cytoplasmic mevalonate (MVA) pathway is the main route for isoprenoid biosynthesis in latex production. In addition to the well-studied polymerization factors, we suggest that rubber elongation factor 8 (REF8) is a candidate factor in cis-polyisoprene biosynthesis. We have also identified 39 transcription factors that may be key regulators in latex production. Expression profile analysis using two additional cultivars, RRIM 901 and PB 350, via an RNA-Seq approach revealed possible expression differences between a high latex-yielding cultivar and a disease-resistant cultivar. PMID:28431015
Mechanical and morphological properties of kenaf powder filled natural rubber latex foam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karim, Ahmad Fikri Abdul, E-mail: a.fikri-89@yahoo.com; Ariff, Zulkifli Mohamad; Ismail, Hanafi
This research is carried out by incorporate kenaf powder with natural rubber latex (NRL) compound and is foamed to make natural rubber latex foam (NRLF) by using a well known technique called Dunlop method. Different loading of kenaf powder was added to NRL compound and was foamed to make NRLF. The tensile properties, and morphology of kenaf filled NRLF was studied. Increase in kenaf loading reduced the tensile strength and elongation at break and of a compound. Modulus at 100% elongation of the compound increased with increased in filler loading. The morphological and micro structural characterization has been performed bymore » using scanning electron microscopy (SEM)« less
USDA-ARS?s Scientific Manuscript database
The fragility of a single-source, geographically concentrated supply of natural rubber, a critical material of the modern economy, has brought guayule (Parthenium argentatum A. Gray) to the forefront as an alternative source of natural rubber. The improvement of guayule for commercial-scale producti...
75 FR 7586 - Baled Natural Rubber in Tires; TSCA Section 21 Petition; Agency Response
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-22
... affect the incidence of Hevea brasiliensis natural-rubber allergies and allergy induced autism.'' After... allergy induced autism'' (Refs. 1 and 2). This petition is similar to a previous petition that the same...?keywords=allergies+and+autism&x=13+y=9 ) dated November 13, 2009, which advertises, and includes an...
Seasonal and clonal variations in technological and thermal properties of raw Hevea natural rubber
USDA-ARS?s Scientific Manuscript database
This study was undertaken over a ten-month period, under the environmental conditions within the state of Mato Grosso, Brazil, to evaluate the causes of variation in technological and thermal properties of raw natural rubber from different clones of Hevea brasiliensis (GT 1, PR 255, FX 3864 and RRIM...
Phan, T N; Lan, N T; Nga, N T
2004-05-01
Natural rubber from hevea brasiliensis trees (Thailand, RRIM 600 clone) of different age (8, 20, and 35 years) were characterized by size exclusion chromatography coupled with online viscometry according to their distribution of molar mass and branching index at a temperature of 70 degrees C using cyclohexane as solvent. Washing with an aqueous solution of sodium dodecylsulfate and subsequent saponification purified the natural rubber samples. With this procedure physical branching points caused by phospholipids, proteins and hydrophobic terminal units, mainly fatty acids, of the natural rubber (cis-1,4-polyisoprene) molecule, could be removed leading to completely soluble polymer samples. All samples investigated possess a very broad (10 to 50,000 kg/mol) and distinct bimodal molar mass distribution. With increasing age the peak area in the low molar mass region decreases favoring the peak area in the high molar mass region. By plotting the branching index as a function of the both, the molar mass and the age of the trees.
Highly Sensitive and Very Stretchable Strain Sensor Based on a Rubbery Semiconductor.
Kim, Hae-Jin; Thukral, Anish; Yu, Cunjiang
2018-02-07
There is a growing interest in developing stretchable strain sensors to quantify the large mechanical deformation and strain associated with the activities for a wide range of species, such as humans, machines, and robots. Here, we report a novel stretchable strain sensor entirely in a rubber format by using a solution-processed rubbery semiconductor as the sensing material to achieve high sensitivity, large mechanical strain tolerance, and hysteresis-less and highly linear responses. Specifically, the rubbery semiconductor exploits π-π stacked poly(3-hexylthiophene-2,5-diyl) nanofibrils (P3HT-NFs) percolated in silicone elastomer of poly(dimethylsiloxane) to yield semiconducting nanocomposite with a large mechanical stretchability, although P3HT is a well-known nonstretchable semiconductor. The fabricated strain sensors exhibit reliable and reversible sensing capability, high gauge factor (gauge factor = 32), high linearity (R 2 > 0.996), and low hysteresis (degree of hysteresis <12%) responses at the mechanical strain of up to 100%. A strain sensor in this format can be scalably manufactured and implemented as wearable smart gloves. Systematic investigations in the materials design and synthesis, sensor fabrication and characterization, and mechanical analysis reveal the key fundamental and application aspects of the highly sensitive and very stretchable strain sensors entirely from rubbers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oka, Jude M.
Present day glovebox gloves at Los Alamos National Laboratory (LANL) are underdeveloped and ergonomically inaccurate. This problem results in numerous sprain and strain injuries every year for employees who perform glovebox work. In addition to injuries, using the current glovebox glove design also contributes to breaches and contamination. The current glove used today at LANL has several problems: (1) The length of the fingers is incorrect, (2) the web spacing between the fingers is nonexistent, (3) the angles between each digit on the finger are incorrect, (4) the thumb is placed inaccurately, and (5) the length of the hand ismore » incorrect. These problems present a need to correct the current glove design to decrease the risk of injuries, breaches, and contamination. Anthropometrics were researched to help find the best range of hand measurements to fix the current glove design. Anthropometrics is the measure of the human physical variation. Anthropometrics for this study were gathered from the American National Survey (ANSUR) data that was conducted by the U.S Army in 1988. The current glovebox glove uses anthropometrics from the 95th to 105th percentile range which is too large so the new gloves are going to implement data from a smaller range of percentile groups. The 105th percentile range represents measurements that exceed the human population but are needed to fit certain circumstance such as wearing several under gloves within the glovebox gloves. Anthropometrics used in this study include: 105th percentile measurements for joint circumference which was unchanged because the room for under gloves plus ease of hand insertion and extraction is needed, 80th percentile measurements for crotch length to allow workers to reach the web spacing in the glove, 20th percentile measurements for finger length to allow workers to reach the end of the glove, standard 10.5cm hand breadth to allow more room to accommodate under gloves, 45 degrees abduction angle for the thumb for better positioning, 45 degrees extension angle for the thumb for better positioning, and various angles for the other fingers to allow a more relaxed and natural fit. 3D modeling was used to implement the anthropometric data listed above onto an existing scanned solid model of a human hand. SolidWorks 2010 3-D modeling package was utilized to manipulate the hand model to represent the anthropometric data researched. The anthropometrics and modifications were reviewed by the University of New Mexico Department of Orthopedics hand surgeons. After all modifications and reviews were completed the model was printed out using stereolithography. The printed out model of the hand was used as a mold to create a prototype glovebox glove. The new mold was taken to Piercan USA to produce a 20mil Polyurethane/Hypalon glovebox glove. The Minnesota Dexterity test and Purdue Pegboard test were used to measure the dexterity of the prototype glovebox glove against a current 15 mil Hypalon LANL glovebox glove. Using the data from the tests a student t test was used to determine if there was a significant difference between the current hypalon glove results and the new prototype glove results. With a 95% confidence level the prototype showed to have a significantly lower mean difference from the current hypalon glovebox glove with the Minnesota Dexterity test. With a 95% confidence level the prototype showed to have a significantly higher mean difference from the current hypalon glovebox glove with the Purdue Pegboard test. A p value method was also performed to confirm the results of the student t test. A survey was also given to glovebox workers to determine if they preferred the new design. The best reaction from glovebox workers was the new thumb position, 73.2% of the sample population agreed with the new thumb position. Developing a new glovebox glove will improve the ergonomics of the hand for work performed, decrease exposure time, decreasing risk of breaching, increasing productivity, reducing injuries, and improving work performance. In the future the new glovebox glove can also be implemented in other research fields such as: pharmaceutical research and development, semiconducting industry, biohazard industry, and other laboratories conducting nuclear research and development.« less
NASA Technical Reports Server (NTRS)
Anderson, Bianca Trujillo; Meyer, Robert R., Jr.
1990-01-01
The results are discussed of the variable sweep transition flight experiment (VSTFE). The VSTFE was a natural laminar flow experiment flown on the swing wing F-14A aircraft. The main objective of the VSTFE was to determine the effects of wing sweep on boundary layer transition at conditions representative of transport aircraft. The experiment included the flight testing of two laminar flow wing gloves. Glove 1 was a cleanup of the existing F-14A wing. Glove 2, not discussed herein, was designed to provide favorable pressure distributions for natural laminar flow at Mach number (M) 0.700. The transition locations presented for glove 1 were determined primarily by using hot film sensors. Boundary layer rake data was provided as a supplement. Transition data were obtained for leading edge wing sweeps of 15, 20, 25, 30, and 35 degs, with Mach numbers ranging from 0.700 to 0.825, and altitudes ranging from 10,000 to 35,000 ft. Results show that a substantial amount of laminar flow was maintained at all the wing sweeps evaluated. The maximum transition Reynolds number of 13.7 x 10(exp 6) was obtained for the condition of 15 deg of sweep, M = 0.800, and an altitude of 20,000 ft.
Shimada, Kunio; Saga, Norihiko
2016-01-01
Sensors are essential to the fulfillment of every condition of haptic technology, and they need simultaneously to sense shear stress as well as normal force, and temperature. They also must have a strong and simple structure, softness, and large extension. To achieve these conditions simultaneously, we enhanced the sensitivity of sensors utilizing natural rubber (NR)-latex through the application of electrolytic polymerization focused on the isoprene C=C bonds in natural rubbers such as NR-latex, and then applied a magnetic field and magnetic compound fluid (MCF) as magnetically responsive fluid. When an electric field alone was used in the rubber, the effect of electrolytic polymerization was very small compared to the effect in well-known conductive polymer solution such as plastic. The MCF developed by Shimada in 2001 involved magnetite and metal particles, and acts as a filler in NR-latex. By utilizing the magnetic, electric fields and the MCF, we aligned the electrolytically polymerized C=C along the magnetic field line with the magnetic clusters formed by the aggregation of magnetite and metal particles so as to enhance the effect of electrolytic polymerization. We then demonstrated the effectiveness of the new method of rubber vulcanization on the sensitivity of the rubber by experimentally investigating its electric and dynamic characteristics. PMID:27649210
Shimada, Kunio; Saga, Norihiko
2016-09-18
Sensors are essential to the fulfillment of every condition of haptic technology, and they need simultaneously to sense shear stress as well as normal force, and temperature. They also must have a strong and simple structure, softness, and large extension. To achieve these conditions simultaneously, we enhanced the sensitivity of sensors utilizing natural rubber (NR)-latex through the application of electrolytic polymerization focused on the isoprene C=C bonds in natural rubbers such as NR-latex, and then applied a magnetic field and magnetic compound fluid (MCF) as magnetically responsive fluid. When an electric field alone was used in the rubber, the effect of electrolytic polymerization was very small compared to the effect in well-known conductive polymer solution such as plastic. The MCF developed by Shimada in 2001 involved magnetite and metal particles, and acts as a filler in NR-latex. By utilizing the magnetic, electric fields and the MCF, we aligned the electrolytically polymerized C=C along the magnetic field line with the magnetic clusters formed by the aggregation of magnetite and metal particles so as to enhance the effect of electrolytic polymerization. We then demonstrated the effectiveness of the new method of rubber vulcanization on the sensitivity of the rubber by experimentally investigating its electric and dynamic characteristics.
Kotowska, Martyna M; Leuschner, Christoph; Triadiati, Triadiati; Hertel, Dietrich
2016-02-01
Tropical landscapes are not only rapidly transformed by ongoing land-use change, but are additionally confronted by increasing seasonal climate variation. There is an increasing demand for studies analyzing the effects and feedbacks on ecosystem functioning of large-scale conversions of tropical natural forest into intensively managed cash crop agriculture. We analyzed the seasonality of aboveground litterfall, fine root litter production, and aboveground woody biomass production (ANPP(woody)) in natural lowland forests, rubber agroforests under natural tree cover ("jungle rubber"), rubber and oil palm monocultures along a forest-to-agriculture transformation gradient in Sumatra. We hypothesized that the temporal fluctuation of litter production increases with increasing land-use intensity, while the associated nutrient fluxes and nutrient use efficiency (NUE) decrease. Indeed, the seasonal variation of aboveground litter production and ANPP(woody) increased from the natural forest to the plantations, while aboveground litterfall generally decreased. Nutrient return through aboveground litter was mostly highest in the natural forest; however, it was significantly lower only in rubber plantations. NUE of N, P and K was lowest in the oil palm plantations, with natural forest and the rubber systems showing comparably high values. Root litter production was generally lower than leaf litter production in all systems, while the root-to-leaf ratio of litter C flux increased along the land-use intensity gradient. Our results suggest that nutrient and C cycles are more directly affected by climate seasonality in species-poor agricultural systems than in species-rich forests, and therefore might be more susceptible to inter-annual climate fluctuation and climate change.
Development of a Cavitation Erosion Resistant Advanced Material System
2005-11-01
Sheet EPD M results .............................................................................. 47 Figure 5.11 - EPDM rubber samples, sheet (left...Testing The long test times of EPDM rubber and other durable elastomer samples created a need for overnight testing capability. In the original test setup...seals, adhesives and molded flexible parts. Common examples of elastomers include natural and synthetic rubber , silicone, neoprene, EPDM , polyurethane
ERIC Educational Resources Information Center
Sperling, L. H.
1982-01-01
The temperature at which the onset of coordinated segmental motion begins is called the glass-rubber transition temperature (Tg). Natural rubber at room temperature is a good example of a material above its Tg. Describes an experiment examining the response of a typical polymer to temperature variations above and below Tg. (Author/JN)
USDA-ARS?s Scientific Manuscript database
Kazak dandelion (Taraxacum kok-saghyz, Tk) is a rubber-producing plant currently being investigated as a source of natural rubber for industrial applications. Like many other isoprenoids, rubber is a downstream product of the mevalonate pathway. The 3-hydroxy-3-methylglutaryl-CoA reductase (HMGR) en...
NASA Astrophysics Data System (ADS)
Suntako, R.
2018-01-01
Zinc oxide (ZnO) is widely used in rubber industry as a cure activator for rubber vulcanization. In this work, comparison of cure characteristic, mechanical properties, thermal conductivity and volume swell testing in oil no.1 and oil no.3 between natural rubber (NR) filled synthesized ZnO nanoparticles (sZnO) by precipitation method and NR filled conventional ZnO (cZnO). The particle size of sZnO is 41.50 nm and specific area of 27.92 m2/g, the particle size of cZnO is 312.92 nm and specific surface area of 1.35 m2/g. It has been found that NR filled sZnO not only improves rubber mechanical properties, volume swell testing but also improves thermal conductivity and better than NR filled cZnO. Thermal conductivity of NR filled sZnO increases by 10.34%, 12.90% and 20.00%, respectively when compared with NR filled cZnO in same loading content (various concentrations of ZnO at 5, 8 and 10 parts per hundred parts of rubber). This is due to small particle size and large specific surface area of sZnO which lead to an increase in crosslinking in rubber chain and enhance heat transfer performance.
NASA Astrophysics Data System (ADS)
Budiarto
2017-03-01
Study the influence of high concentrations of antioxidants N-isopropyl-N-phenyl-p-phenylenediamine (IPPD) and 2,2,4-trimethyl-1,2-dihydroquinoline (TMQ) and the mixing time of the vulcanization physical properties, thermal properties, mechanical properties and structure micro on natural rubber compound has been done. The purpose of this study is to compare the effect of anti-oxidants types IPPD and TMQ and mixing time of vulcanization of the physical properties, mechanical properties, microstructure and elemental composition of the synthesis of natural rubber compound. Processes of vulcanization with variations in the concentration of antioxidant IPPD and TMQ: 2, 3, and 4 grams and mixing time: 20, 30, and 40 minutes. Analysis characterization of physical properties and mechanical properties of natural rubber compound showed that the maturity value 0,499Nm (TMQ) and 0.489 Nm (IPPD), Mooney viscosity value of 26.7 (TMQ) and 20.8 (IPPD), the value of the elongation at break 583.75 % (IPPD), and 552.63% (TMQ) as well as the value of tensile strength of 28.108 M.Pa (TMQ), and 27.986 M.Pa (IPPD). Analysis of thermal properties of natural rubber compound antioxidant IPPD with DTA shows there are three endothermic peak on the curve that is temperature 405°C, 550°C and 660°C and tested by TGA showed that the curve of the total reduction in the sample are 81.745% and compound rubber antioxidant TMQ with the analysis of DTA also contained 3 endothermic peak at a temperature 397,21°C, 514,02°C, and 610,27°C and TGA analysis shows the curve of the total sample of 82.356% reduction. Gsi fun group analysis rubber-antioxidant compound IPPD / TMQ with FTIR spectrophotometer shows some typical infrared absorption peak at the wave number (1 / λ) 833-895 cm-1 for cluster / CH bonds, 1,313 cm-1 for group / single bond Si-O, 1368 cm-1 to g ugus / single bond CC, 1507 cm-1, for cluster / bond C = C, 1665 cm-1For cluster / bond-C = O, 2128 cm-1 is the group / bond CN single, 3371cm-1 for group-OH, 3506 cm-1 for cluster / CH3 bond and 3585 cm-1 showed the presence of vibration in the cluster / bond-NH. The results of morphological observation with SEM produces uneven surface (homogeneous) and are compatible at 2000 times magnification, as well as the test composition by EDX spectroscopy showed that the biggest element in the rubber compound is carbon and Zn, S, Ca, Si, Mg, Al, N. This shows that the natural rubber compound antioxidant IPPD / TMQ meet the standard of "Mechanical Properties of Industrial Tyre rubber Compounds".
NASA Astrophysics Data System (ADS)
Pongsathit, Siriwan; Pattamaprom, Cattaleeya
2018-03-01
Maleic anhydride (MA) is an interesting monomer to be grafted onto natural rubber(NR) due to its potential as a compatibilizer of hydrophobic rubbers and polymers with higher polarity. So far, radiation grafting of MA onto NR in latex state has not been reported. In this study, the grafting of NR with MA in latex state was investigated by exposing the latex to cobalt-60 gamma irradiation at a fixed MA content of 9% and a varied absorbed doses from 2 to 10 kGy. The FTIR spectrometer, 1H NMR spectrometer and gel content analysis have confirmed successful grafting of MA onto NR after irradiation. The grafted NRs were then used to increase the compatibility and the impact property of PLA/NR blends. It was found that the highest impact strength of the blends was achieved when the grafting was carried out at the absorbed dose of 4 kGy.
Galiullina, E F; Valiev, A v; Kamilov, R F; Shakirov, D F; Buliakov, P T
2013-12-01
The article presents the results of studies concerning the effect of unfavorable factors of chemical nature on fluid of oral cavity among workers of the Ufa plant of elastomer materials, articles and structures. It is established that in persons contacting with chemical pollutants of manufacture of rubber and rubber technical production the indicators of chemiluminescence of saliva fluid are significantly expressed and depend on professional standing.
Chemistry of rubber processing and disposal.
Bebb, R L
1976-01-01
The major chemical changes during the processing of rubber occur with the breakdown in mastication and during vulcanization of the molded tire. There is little chemical change during the compounding, calendering, extrusion, and molding steps. Reclaiming is the process of converting scrap rubber into an unsaturated, processible product that can be vulcanized with sulfur. Pyrolysis of scrap rubber yields a complex mixture of liquids, gas, and residue in varying ratios dependent on the nature of the scrap and the conditions of pyrolysis. PMID:799964
NASA Astrophysics Data System (ADS)
Sun, Zhongchang; Leinenkugel, Patrick; Guo, Huadong; Huang, Chong; Kuenzer, Claudia
2017-04-01
Natural tropical rainforests in China's Xishuangbanna region have undergone dramatic conversion to rubber plantations in recent decades, resulting in altering the region's environment and ecological systems. Therefore, it is of great importance for local environmental and ecological protection agencies to research the distribution and expansion of rubber plantations. The objective of this paper is to monitor dynamic changes of rubber plantations in China's Xishuangbanna region based on multitemporal Landsat images (acquired in 1989, 2000, and 2013) using a C5.0-based decision-tree method. A practical and semiautomatic data processing procedure for mapping rubber plantations was proposed. Especially, haze removal and deshadowing were proposed to perform atmospheric and topographic correction and reduce the effects of haze, shadow, and terrain. Our results showed that the atmospheric and topographic correction could improve the extraction accuracy of rubber plantations, especially in mountainous areas. The overall classification accuracies were 84.2%, 83.9%, and 86.5% for the Landsat images acquired in 1989, 2000, and 2013, respectively. This study also found that the Landsat-8 images could provide significant improvement in the ability to identify rubber plantations. The extracted maps showed the selected study area underwent rapid conversion of natural and seminatural forest to a rubber plantations from 1989 to 2013. The rubber plantation area increased from 2.8% in 1989 to 17.8% in 2013, while the forest/woodland area decreased from 75.6% in 1989 to 44.8% in 2013. The proposed data processing procedure is a promising approach to mapping the spatial distribution and temporal dynamics of rubber plantations on a regional scale.
NASA Astrophysics Data System (ADS)
Surya, Indra; Fauzi Siregar, Syahrul; Ismail, Hanafi
2018-03-01
Effects of alkanolamide (ALK) addition on cure characteristics, swelling behaviour and tensile properties of silica-filled natural rubber (NR)/chloroprene rubber (CR) blends were investigated. The ALK was synthesized from Refined Bleached Deodorized Palm Stearin (RBDPS) and diethanolamine, and incorporated into the silica-filled NR/CR blends as a non-toxic rubber additive. The ALK loadings were 0.0, 1.0, 3.0, 5.0 and 7.0 phr. It was found that the ALK exhibited shorter scorch and cure times and higher elongation at break of the silica-filled NR/CR blends. The ALK also exhibited higher torque differences, tensile modulus and tensile strength at a 1.0 phr of ALK loading and then decreased with further increases in the ALK loading. The swelling measurement proved that the 1.0 phr loading of ALK caused the highest degree in crosslink density of the silica-filled NR/CR blends.
NASA Astrophysics Data System (ADS)
Daud, Shuhairiah; Ismail, Hanafi; Bakar, Azhar Abu
2017-07-01
The effect of partial replacement of palm kernel shell powder by carbon black (CB) and halloysite nanotube (HNT) on the tensile properties, rubber-filler interaction, thermal properties and morphological studies of natural rubber (NR) composites were investigated. Four different compositions of NR/PKS/CB and NR/PKS/HNT composites i.e 20/0, 15/5, 10/10,5/15 and 0/20 parts per hundred rubber (phr) were prepared on a two roll mill. The results showed that the tensile strength and modulus at 100% elongation (M100) and 300% elongation (M300) were higher for NR/PKS/CB compared to NR/PKS/HNT composites. NR/PKS/CB composites had the lowest elongation at break (Eb). The effect of commercial fillers in NR/PKS composites on tensile properties was confirmed by the rubber-filler interaction and scanning electron microscopy (SEM) study. The thermal stability of PKS filled NR composites with partially replaced by commercial fillers also determined by Thermo gravimetric Analysis (TGA).
Anthropomorphic teleoperation: Controlling remote manipulators with the DataGlove
NASA Technical Reports Server (NTRS)
Hale, J. P., II
1992-01-01
A two phase effort was conducted to assess the capabilities and limitations of the DataGlove, a lightweight glove input device that can output signals in real-time based on hand shape, orientation, and movement. The first phase was a period for system integration, checkout, and familiarization in a virtual environment. The second phase was a formal experiment using the DataGlove as input device to control the protoflight manipulator arm (PFMA) - a large telerobotic arm with an 8-ft reach. The first phase was used to explore and understand how the DataGlove functions in a virtual environment, build a virtual PFMA, and consider and select a reasonable teleoperation control methodology. Twelve volunteers (six males and six females) participated in a 2 x 3 (x 2) full-factorial formal experiment using the DataGlove to control the PFMA in a simple retraction, slewing, and insertion task. Two within-subjects variables, time delay (0, 1, and 2 seconds) and PFMA wrist flexibility (rigid/flexible), were manipulated. Gender served as a blocking variable. A main effect of time delay was found for slewing and total task times. Correlations among questionnaire responses, and between questionnaire responses and session mean scores and gender were computed. The experimental data were also compared with data collected in another study that used a six degree-of-freedom handcontroller to control the PFMA in the same task. It was concluded that the DataGlove is a legitimate teleoperations input device that provides a natural, intuitive user interface. From an operational point of view, it compares favorably with other 'standard' telerobotic input devices and should be considered in future trades in teleoperation systems' designs.
NASA Technical Reports Server (NTRS)
Anderson, Bianca Trujillo; Meyer, Robert R., Jr.
1990-01-01
The variable sweep transition flight experiment (VSTFE) was conducted on an F-14A variable sweep wing fighter to examine the effect of wing sweep on natural boundary layer transition. Nearly full span upper surface gloves, extending to 60 percent chord, were attached to the F-14 aircraft's wings. The results are presented of the glove 2 flight tests. Glove 2 had an airfoil shape designed for natural laminar flow at a wing sweep of 20 deg. Sample pressure distributions and transition locations are presented with the complete results tabulated in a database. Data were obtained at wing sweeps of 15, 20, 25, 30, and 35 deg, at Mach numbers ranging from 0.60 to 0.79, and at altitudes ranging from 10,000 to 35,000 ft. Results show that a substantial amount of laminar flow was maintained at all the wing sweeps evaluated. The maximum transition Reynolds number obtained was 18.6 x 10(exp 6) at 15 deg of wing sweep, Mach 0.75, and at an altitude of 10,000 ft.
USDA-ARS?s Scientific Manuscript database
The tire industry is currently considering natural rubber from guayule (Parthenium argentatum Gray) as a viable alternative to imported Hevea natural rubber, or petroleum-based synthetics, to meet expanding materials needs of the industry, however, only 5-10% of the harvested guayule plant is conver...
49 CFR 372.115 - Commodities that are not exempt under 49 U.S.C. 13506(a)(6).
Code of Federal Regulations, 2012 CFR
2012-10-01
... extracted from grain Popcorn, popped Rice, precooked Wheat germ Gravel Hair, hog or other animal, product of... Pulp, sugar cane Rock (except natural crushed, vesicular rock to be used for decorative purposes) Rubber, crude, in bales Rubber, latex, natural, liquid, from which water has been extracted and to which...
49 CFR 372.115 - Commodities that are not exempt under 49 U.S.C. 13506(a)(6).
Code of Federal Regulations, 2014 CFR
2014-10-01
... extracted from grain Popcorn, popped Rice, precooked Wheat germ Gravel Hair, hog or other animal, product of... Pulp, sugar cane Rock (except natural crushed, vesicular rock to be used for decorative purposes) Rubber, crude, in bales Rubber, latex, natural, liquid, from which water has been extracted and to which...
49 CFR 372.115 - Commodities that are not exempt under 49 U.S.C. 13506(a)(6).
Code of Federal Regulations, 2013 CFR
2013-10-01
... extracted from grain Popcorn, popped Rice, precooked Wheat germ Gravel Hair, hog or other animal, product of... Pulp, sugar cane Rock (except natural crushed, vesicular rock to be used for decorative purposes) Rubber, crude, in bales Rubber, latex, natural, liquid, from which water has been extracted and to which...
49 CFR 372.115 - Commodities that are not exempt under 49 U.S.C. 13506(a)(6).
Code of Federal Regulations, 2011 CFR
2011-10-01
... extracted from grain Popcorn, popped Rice, precooked Wheat germ Gravel Hair, hog or other animal, product of... Pulp, sugar cane Rock (except natural crushed, vesicular rock to be used for decorative purposes) Rubber, crude, in bales Rubber, latex, natural, liquid, from which water has been extracted and to which...
USDA-ARS?s Scientific Manuscript database
Renewable corn flour has a significant reinforcement effect in natural rubber. The corn flour was hydrolyzed and microfluidized to reduce its particle size. Greater than 90% of the hydrolyzed corn flour had an average size of ~300 nm, a reduction of 33 times compared to unhydrolyzed corn flour. Comp...
Robust and biodegradable polymer of cassava starch and modified natural rubber.
Riyajan, Sa-Ad
2015-12-10
The application of starch based materials for packaging purposes has attracted significant interest because they are both cheap and renewable resources. The study investigated the preparation and properties of a novel biopolymer sheet produced from a blend of maleated epoxidized natural rubber (MENR) and natural rubber-g-cassava starch (NR-g-CSt). The water resistance, toluene resistance and elongation at break of the polymer blend were enhanced after the addition of the MENR compared to pristine NR-g-CSt. The maximum tensile strength and thermal stability of the NR-g-CSt/MENR blend were found in the 100:50 NR-g-CSt:MENR blend. The novel films demonstrated good biodegradability in soil. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hayeemasae, N.; Surya, I.; Ismail, H.
2018-02-01
This paper deals with the morphology and thermal stability of nano Titanium Dioxide (TiO2) filled natural rubber composites. This study also suggests a new method of incorporating TiO2. Aqueous dispersions of nano TiO2at the loadings of 0, 2, 4, 6 and 8 phr were dispersed in natural rubber latex, the resulting compounds were then dried prior to mixing it with other ingredients on a two-roll mill. By applying this technique, the homogeneity of the compound is significantly improved. This can be clearly seen from the morphology observed. Adding TiO2 results in shifting the decomposition temperature and char residue irrespective of the loadings of nano TiO2.
Large-scale collection of full-length cDNA and transcriptome analysis in Hevea brasiliensis.
Makita, Yuko; Ng, Kiaw Kiaw; Veera Singham, G; Kawashima, Mika; Hirakawa, Hideki; Sato, Shusei; Othman, Ahmad Sofiman; Matsui, Minami
2017-04-01
Natural rubber has unique physical properties that cannot be replaced by products from other latex-producing plants or petrochemically produced synthetic rubbers. Rubber from Hevea brasiliensis is the main commercial source for this natural rubber that has a cis-polyisoprene configuration. For sustainable production of enough rubber to meet demand elucidation of the molecular mechanisms involved in the production of latex is vital. To this end, we firstly constructed rubber full-length cDNA libraries of RRIM 600 cultivar and sequenced around 20,000 clones by the Sanger method and over 15,000 contigs by Illumina sequencer. With these data, we updated around 5,500 gene structures and newly annotated around 9,500 transcription start sites. Second, to elucidate the rubber biosynthetic pathways and their transcriptional regulation, we carried out tissue- and cultivar-specific RNA-Seq analysis. By using our recently published genome sequence, we confirmed the expression patterns of the rubber biosynthetic genes. Our data suggest that the cytoplasmic mevalonate (MVA) pathway is the main route for isoprenoid biosynthesis in latex production. In addition to the well-studied polymerization factors, we suggest that rubber elongation factor 8 (REF8) is a candidate factor in cis-polyisoprene biosynthesis. We have also identified 39 transcription factors that may be key regulators in latex production. Expression profile analysis using two additional cultivars, RRIM 901 and PB 350, via an RNA-Seq approach revealed possible expression differences between a high latex-yielding cultivar and a disease-resistant cultivar. © The Author 2017. Published by Oxford University Press on behalf of Kazusa DNA Research Institute.
In-depth proteome analysis of the rubber particle of Hevea brasiliensis (para rubber tree).
Dai, Longjun; Kang, Guijuan; Li, Yu; Nie, Zhiyi; Duan, Cuifang; Zeng, Rizhong
2013-05-01
The rubber particle is a special organelle in which natural rubber is synthesised and stored in the laticifers of Hevea brasiliensis. To better understand the biological functions of rubber particles and to identify the candidate rubber biosynthesis-related proteins, a comprehensive proteome analysis was performed on H. brasiliensis rubber particles using shotgun tandem mass spectrometry profiling approaches-resulting in a thorough report on the rubber particle proteins. A total of 186 rubber particle proteins were identified, with a range in relative molecular mass of 3.9-194.2 kDa and in isoelectric point values of 4.0-11.2. The rubber particle proteins were analysed for gene ontology and could be categorised into eight major groups according to their functions: including rubber biosynthesis, stress- or defence-related responses, protein processing and folding, signal transduction and cellular transport. In addition to well-known rubber biosynthesis-related proteins such as rubber elongation factor (REF), small rubber particle protein (SRPP) and cis-prenyl transferase (CPT), many proteins were firstly identified to be on the rubber particles, including cyclophilin, phospholipase D, cytochrome P450, small GTP-binding protein, clathrin, eukaryotic translation initiation factor, annexin, ABC transporter, translationally controlled tumour protein, ubiquitin-conjugating enzymes, and several homologues of REF, SRPP and CPT. A procedure of multiple reaction monitoring was established for further protein validation. This comprehensive proteome data of rubber particles would facilitate investigation into molecular mechanisms of biogenesis, self-homeostasis and rubber biosynthesis of the rubber particle, and might serve as valuable biomarkers in molecular breeding studies of H. brasiliensis and other alternative rubber-producing species.
Fels, S S; Hinton, G E
1998-01-01
Glove-TalkII is a system which translates hand gestures to speech through an adaptive interface. Hand gestures are mapped continuously to ten control parameters of a parallel formant speech synthesizer. The mapping allows the hand to act as an artificial vocal tract that produces speech in real time. This gives an unlimited vocabulary in addition to direct control of fundamental frequency and volume. Currently, the best version of Glove-TalkII uses several input devices (including a Cyberglove, a ContactGlove, a three-space tracker, and a foot pedal), a parallel formant speech synthesizer, and three neural networks. The gesture-to-speech task is divided into vowel and consonant production by using a gating network to weight the outputs of a vowel and a consonant neural network. The gating network and the consonant network are trained with examples from the user. The vowel network implements a fixed user-defined relationship between hand position and vowel sound and does not require any training examples from the user. Volume, fundamental frequency, and stop consonants are produced with a fixed mapping from the input devices. One subject has trained to speak intelligibly with Glove-TalkII. He speaks slowly but with far more natural sounding pitch variations than a text-to-speech synthesizer.
NASA Astrophysics Data System (ADS)
Royani, J. I.; Safarrida, A.; Rachmawati, I.; Khairiyah, H.; Mustika, I. P.; Suyono, A.; Rudiyana, Y.; Kubil; Nurjaya; Arianto, A.
2017-05-01
Rubber from Hevea brasiliensis is the only commercial natural rubber in the world. Propagation of rubber trees usually done by grafting and seed germination. BPPT had been producing rubber tree by in vitro technique with embryo somatic methods. Validation of mother plant for in vitro propagation is important to compare between mother plant and propagated plants. The aim for this research was to validation of PB 260 clone that planted at Cikumpay Plantation by SSR marker. Sampling of 10 rubber leaves were done at Cikumpay Plantation based on GPS position from the area of PB 260 clone. Rubber leaves were isolated with CTAB modification method to obtained DNA. Four of SSR primers from rubber, i.e.: hmac 4, hmac 5, hmct 1, and hmct 5, were used as primers to amplification of rubber DNA. The result showed that no band that different from 10 rubber of PB 260 clone at Cikumpay Plantation. This research will continue to compare genomic validation between mother plant and propagated plants that had been produced from BPPT.
Subcellular localization and interactions among rubber particle proteins from Hevea brasiliensis.
Brown, Daniel; Feeney, Mistianne; Ahmadi, Mathin; Lonoce, Chiara; Sajari, Roslinda; Di Cola, Alessandra; Frigerio, Lorenzo
2017-11-02
Natural rubber (polyisoprene) from the rubber tree Hevea brasiliensis is synthesized by specialized cells called laticifers. It is not clear how rubber particles arise, although one hypothesis is that they derive from the endoplasmic reticulum (ER) membrane. Here we cloned the genes encoding four key proteins found in association with rubber particles and studied their intracellular localization by transient expression in Nicotiana benthamiana leaves. We show that, while the cis-prenyltransferase (CPT), responsible for the synthesis of long polyisoprene chains, is a soluble, cytosolic protein, other rubber particle proteins such as rubber elongation factor (REF), small rubber particle protein (SRPP) and Hevea rubber transferase 1-REF bridging protein (HRBP) are associated with the endoplasmic reticulum (ER). We also show that SRPP can recruit CPT to the ER and that interaction of CPT with HRBP leads to both proteins relocating to the plasma membrane. We discuss these results in the context of the biogenesis of rubber particles. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.
Virtual Hand Illusion Induced by Visuomotor Correlations
Sanchez-Vives, Maria V.; Spanlang, Bernhard; Frisoli, Antonio; Bergamasco, Massimo; Slater, Mel
2010-01-01
Background Our body schema gives the subjective impression of being highly stable. However, a number of easily-evoked illusions illustrate its remarkable malleability. In the rubber-hand illusion, illusory ownership of a rubber-hand is evoked by synchronous visual and tactile stimulation on a visible rubber arm and on the hidden real arm. Ownership is concurrent with a proprioceptive illusion of displacement of the arm position towards the fake arm. We have previously shown that this illusion of ownership plus the proprioceptive displacement also occurs towards a virtual 3D projection of an arm when the appropriate synchronous visuotactile stimulation is provided. Our objective here was to explore whether these illusions (ownership and proprioceptive displacement) can be induced by only synchronous visuomotor stimulation, in the absence of tactile stimulation. Methodology/Principal Findings To achieve this we used a data-glove that uses sensors transmitting the positions of fingers to a virtually projected hand in the synchronous but not in the asynchronous condition. The illusion of ownership was measured by means of questionnaires. Questions related to ownership gave significantly larger values for the synchronous than for the asynchronous condition. Proprioceptive displacement provided an objective measure of the illusion and had a median value of 3.5 cm difference between the synchronous and asynchronous conditions. In addition, the correlation between the feeling of ownership of the virtual arm and the size of the drift was significant. Conclusions/Significance We conclude that synchrony between visual and proprioceptive information along with motor activity is able to induce an illusion of ownership over a virtual arm. This has implications regarding the brain mechanisms underlying body ownership as well as the use of virtual bodies in therapies and rehabilitation. PMID:20454463
Tribology and Friction of Soft Materials: Mississippi State Case Study
2010-03-18
elastomers , foams, and fabrics. B. Develop internal state variable (ISV) material model. Model will be calibrated using database and verified...Rubbers Natural rubber Santoprene (Vulcanized Elastomer ) Styrene Butadiene Rubber (SBR) Foams Polypropylene Foam Polyurethane Foam Fabrics Kevlar...Axially symmetric model PC Disk PC Numerical Implementation in FEM Codes Experiment SEM Optical methods ISV Model Void Nucleation FEM Analysis
System and method for changing a glove attached to a glove box
Aluisi, Alan
2001-01-01
A system for changing the gloves of a glove box. The system requires the use of a new glove and a glove change ring to form a temporary secondary barrier to the exchange of atmospheres between the inner glove box and the room in which the glove box is operated. The system describes specific means for disengaging a used glove from the glove box port. The means for disengaging the used glove include use of a glove change hook and use of a glove with an attached tab for use in removal. A method for changing the gloves of a glove box is also described.
Liu, Shujin; Lan, Jixian; Zhou, Binhui; Qin, Yunxia; Zhou, Yihua; Xiao, Xiaohu; Yang, Jianghua; Gou, Jiqing; Qi, Jiyan; Huang, Yacheng; Tang, Chaorong
2015-04-01
In Hevea brasiliensis, an alkaline/neutral invertase (A/N-Inv) is responsible for sucrose catabolism in latex (essentially the cytoplasm of rubber-producing laticifers, the source of natural rubber) and implicated in rubber yield. However, neither the gene encoding this enzyme nor its molecular and biochemical properties have been well documented. Three Hevea A/N-Inv genes, namely HbNIN1, 2 and 3, were first cloned and characterized in planta and in Escherichia coli. Cellular localizations of HbNIN2 mRNA and protein were probed. From latex, active A/N-Inv proteins were purified, identified, and explored for enzymatic properties. HbNIN2 was identified as the major A/N-Inv gene functioning in latex based on its functionality in E. coli, its latex-predominant expression, the conspicuous localization of its mRNA and protein in the laticifers, and its expressional correlation with rubber yield. An active A/N-Inv protein was partially purified from latex, and determined as HbNIN2. The enhancement of HbNIN2 enzymatic activity by pyridoxal is peculiar to A/N-Invs in other plants. We conclude that HbNIN2, a cytosolic A/N-Inv, is responsible for sucrose catabolism in rubber laticifers. The results contribute to the studies of sucrose catabolism in plants as a whole and natural rubber synthesis in particular. © 2015 The Authors. New Phytologist © 2015 New Phytologist Trust.
NASA Astrophysics Data System (ADS)
Ahmad, Hazwani Syaza; Ismail, Hanafi; Rashid, Azura A.
2017-07-01
This recent work is to investigate the hardness and swelling behaviour of epoxidized natural rubber/recycled acrylonitrile-butadiene rubber (ENR 50/NBRr) blends. ENR 50/NBRr blends were prepared by two-roll mills with five different loading of NBRr from 5 to 35 phr. Results indicated that the hardness of ENR 50/NBRr blends increased as recycled NBR increased due to the improvement in crosslink density of the blends. Increasing NBRr content gives ENR 50/NBRr blends better resistance towards swelling. Higher degree of crosslinking will increase the swelling resistance and reduce the penetration of toluene into the blends. The presence of polar group in ENR 50 and NBRr give better hardness properties and swelling behaviour of the ENR 50/NBRr blends compared to the NR/NBRr blends.
Draft genome sequence of the rubber tree Hevea brasiliensis.
Rahman, Ahmad Yamin Abdul; Usharraj, Abhilash O; Misra, Biswapriya B; Thottathil, Gincy P; Jayasekaran, Kandakumar; Feng, Yun; Hou, Shaobin; Ong, Su Yean; Ng, Fui Ling; Lee, Ling Sze; Tan, Hock Siew; Sakaff, Muhd Khairul Luqman Muhd; Teh, Beng Soon; Khoo, Bee Feong; Badai, Siti Suriawati; Aziz, Nurohaida Ab; Yuryev, Anton; Knudsen, Bjarne; Dionne-Laporte, Alexandre; Mchunu, Nokuthula P; Yu, Qingyi; Langston, Brennick J; Freitas, Tracey Allen K; Young, Aaron G; Chen, Rui; Wang, Lei; Najimudin, Nazalan; Saito, Jennifer A; Alam, Maqsudul
2013-02-02
Hevea brasiliensis, a member of the Euphorbiaceae family, is the major commercial source of natural rubber (NR). NR is a latex polymer with high elasticity, flexibility, and resilience that has played a critical role in the world economy since 1876. Here, we report the draft genome sequence of H. brasiliensis. The assembly spans ~1.1 Gb of the estimated 2.15 Gb haploid genome. Overall, ~78% of the genome was identified as repetitive DNA. Gene prediction shows 68,955 gene models, of which 12.7% are unique to Hevea. Most of the key genes associated with rubber biosynthesis, rubberwood formation, disease resistance, and allergenicity have been identified. The knowledge gained from this genome sequence will aid in the future development of high-yielding clones to keep up with the ever increasing need for natural rubber.
Draft genome sequence of the rubber tree Hevea brasiliensis
2013-01-01
Background Hevea brasiliensis, a member of the Euphorbiaceae family, is the major commercial source of natural rubber (NR). NR is a latex polymer with high elasticity, flexibility, and resilience that has played a critical role in the world economy since 1876. Results Here, we report the draft genome sequence of H. brasiliensis. The assembly spans ~1.1 Gb of the estimated 2.15 Gb haploid genome. Overall, ~78% of the genome was identified as repetitive DNA. Gene prediction shows 68,955 gene models, of which 12.7% are unique to Hevea. Most of the key genes associated with rubber biosynthesis, rubberwood formation, disease resistance, and allergenicity have been identified. Conclusions The knowledge gained from this genome sequence will aid in the future development of high-yielding clones to keep up with the ever increasing need for natural rubber. PMID:23375136
Mechanical Properties of Graphene-Rubber Nanocomposites
NASA Astrophysics Data System (ADS)
Anhar, N. A. M.; Ramli, M. M.; Hambali, N. A. M. A.; Aziz, A. A.; Mat Isa, S. S.; Danial, N. S.; Abdullah, M. M. A. B.
2017-11-01
This research focused on development of wearable sensor device by using Prevulcanized Natural Rubber (PV) and Epoxidized Natural Rubber (ENR 50) latex incorporated with graphene oxide (GO), graphene paste, graphene powder and reduced graphene oxide (rGO) powder. The compounding formulation and calculation were based on phr (parts per hundred rubber) and all the samples were then tested for mechanical properties using Instron 5565 machine. It was found that the sonication effects on tensile strength may have better quality of tensile strength compared to non-sonicated GO. For PV incorporate GO, the optimum loading was best determined at loading 1.5 phr with or without sonication and similar result was recorded for PV/G. For ENR 50 incorporate graphene paste and rGO powder nanocomposite shows the best optimum was at 3.0 phr with 24 hours’ sonication.
Pronk, A; Yu, F; Vlaanderen, J; Tielemans, E; Preller, L; Bobeldijk, I; Deddens, J A; Latza, U; Baur, X; Heederik, D
2006-09-01
To study inhalation and dermal exposure to hexamethylene diisocyanate (HDI) and its oligomers as well as personal protection equipment (PPE) use during task performance in conjunction with urinary hexamethylene diamine (HDA) in car body repair shop workers and industrial spray painters. Personal task based inhalation samples (n = 95) were collected from six car body repair shops and five industrial painting companies using impingers with di-n-butylamine (DBA) in toluene. In parallel, dermal exposure was assessed using nitril rubber gloves. Gloves were submerged into DBA in toluene after sampling. Analysis for HDI and its oligomers was performed by LC-MS/MS. Urine samples were collected from 55 workers (n = 291) and analysed for HDA by GC-MS. Inhalation exposure was strongly associated with tasks during which aerosolisation occurs. Dermal exposure occurred during tasks that involve direct handling of paint. In car body repair shops associations were found between detectable dermal exposure and glove use (odds ratio (OR) 0.22, 95% confidence interval (CI) 0.09 to 0.57) and inhalation exposure level (OR 1.34, 95% CI 0.97 to 1.84 for a 10-fold increase). HDA in urine could be demonstrated in 36% and 10% of car body repair shop workers and industrial painting company workers respectively. In car body repair shops, the frequency of detectable HDA was significantly elevated at the end of the working day (OR 2.13, 95% CI 1.07 to 4.22 for 3-6 pm v 0-8 am). In both branches HDA was detected in urine of approximately 25% of the spray painters. In addition HDA was detected in urine of a large proportion of non-spray painters in car body repair shops. Although (spray) painting with lacquers containing isocyanate hardeners results in the highest external exposures to HDI and oligomers, workers that do not perform paint related tasks may also receive a considerable internal dose.
Knitted outer gloves in primary hip and knee arthroplasty.
Tanner, J; Wraighte, P; Howard, P
2006-01-01
A randomised trial was carried out to determine the rate of perforation to inner gloves when comparing latex with knitted gloves during hip and knee arthroplasty. Members of the surgical team were randomised to wear either two pairs of latex gloves (standard double gloving) or a knitted glove on top of a latex glove. In addition, participants completed a visual analogue assessment of their overall satisfaction with the gloves. A total of 406 inner gloves were tested for perforations over a four-month period: 23% of inner gloves were perforated when latex outer gloves were used and 6% of inner gloves were perforated when knitted outer gloves were used. In total, there were 64 perforations to the inner gloves; only one of these perforations was detected by the glove wearer. Wearing knitted outer gloves during hip and knee arthroplasty statistically significantly reduces the risk of perforation to inner latex gloves (p<0.0001).
The Influence of Chemical Structure on the Strength of Rubber.
1986-04-01
sticky, as if covered with an oily or tarry film. The debris from carbon-black-filled natural rubber vulcanizates is even more highly degraded , so...RD-RI66 355 THE INFLUENCE OF CHEMICAL STRUCTURE ON THE STRENGTH OF 1 1) RS 5355 RUBBER (U) KRON UNJY OH INST OF POLYMER SCIENCE UNCLSSIFEIDA N GENT...85-K-0222 .- Project NR 092-555 UTechnical Report No. 4 THE INFLUENCE OF CHEMICAL STRUCTURE ON THE * 4: STRENGTH OF RUBBER by S 2LECTE by A P R 0 9 I
Simple green approach to reinforce natural rubber with bacterial cellulose nanofibers.
Trovatti, Eliane; Carvalho, Antonio J F; Ribeiro, Sidney J L; Gandini, Alessandro
2013-08-12
Natural rubber (NR) is a renewable polymer with a wide range of applications, which is constantly tailored, further increasing its utilizations. The tensile strength is one of its most important properties susceptible of being enhanced by the simple incorporation of nanofibers. The preparation and characterization of natural-rubber based nanocomposites reinforced with bacterial cellulose (BC) and bacterial cellulose coated with polystyrene (BCPS), yielded high performance materials. The nanocomposites were prepared by a simple and green process, and characterized by tensile tests, dynamical mechanical analysis (DMA), scanning electron microscopy (SEM), and swelling experiments. The effect of the nanofiber content on morphology, static, and dynamic mechanical properties was also investigated. The results showed an increase in the mechanical properties, such as Young's modulus and tensile strength, even with modest nanofiber loadings.
Effect of epoxidation on 30% poly(methyl methacrylate)-grafted natural rubber polymer electrolytes
NASA Astrophysics Data System (ADS)
Nazir, Khuzaimah; Aziz, Ahmad Fairoz; Adam, Nurul Ilham; Yahya, Muhd Zu Azhan; Ali, Ab Malik Marwan
2015-08-01
Epoxidized 30% poly(methyl methacrylate)-grafted natural rubber (EMG 30) as a polymer host in solid polymer electrolytes (SPEs) has been investigated. EMG30 was synthesized via performicepoxidation method onto 30% poly(methyl methacrylate)-grafted natural rubber (MG30) and the formations of epoxy group were discussed. The EMG30 were characterized by proton nuclear magnetic resonance (1HNMR) to investigate their chemical structure and differential scanning calorimeter to determine their crystallinity. A new peak in 1HNMR spectra (2.71 ppm) confirmed the appearance of epoxy group. SPE based on EMG30 doped with 40 wt% LiCF3SO3 show the highest conductivity. The complexation between EMG30 and LiCF3SO3 were confirmed by attenuated total reflection Fourier transform infrared (ATR-FTIR).
Electrical and Electrorheological Properties of Alumina/Natural Rubber (STR XL) Composites
Tangboriboon, Nuchnapa; Uttanawanit, Nuttapot; Longtong, Mean; Wongpinthong, Piraya; Sirivat, Anuvat; Kunanuruksapong, Ruksapong
2010-01-01
The electrorheological properties (ER) of natural rubber (XL)/alumina (Al2O3) composites were investigated in oscillatory shear mode under DC electrical field strengths between 0 to 2 kV/mm. SEM micrographs indicate a mean particle size of 9.873 ± 0.034 µm and particles that are moderately dispersed in the matrix. The XRD patterns indicate Al2O3 is of the β-phase polytype which possesses high ionic conductivity. The storage modulus (G′) of the composites, or the rigidity, increases by nearly two orders of magnitude, with variations in particle volume fraction and electrical field strength. The increase in the storage modulus is caused the ionic polarization of the alumina particles and the induced dipole moments set up in the natural rubber matrix.
Wearing gloves in the hospital
Infection control - wearing gloves; Patient safety - wearing gloves; Personal protective equipment - wearing gloves; PPE - wearing gloves; Nosocomial infection - wearing gloves; Hospital acquired infection - wearing gloves
Wang, Yong-Xin; Xue, Dan-Ting; Liu, Meng; Zhou, Zheng-Min; Shang, Jing
2016-03-01
The present study aimed at developing a natural compound with anti-allergic effect and stability under latex glove manufacturing conditions and investigating whether its anti-allergic effect is maintained after its addition into the latex. The effects of nine natural compounds on growth of the RBL-2H3 cells and mouse primary spleen lymphocytes were determined using MTT assay. The compounds included glycyrrhizin, osthole, tetrandrine, tea polyphenol, catechin, arctigenin, oleanolic acid, baicalin and oxymatrine. An ELISA assay was used for the in vitro anti-type I/IV allergy screening; in this process β-hexosaminidase, histamine, and IL-4 released from RBL-2H3 cell lines and IFN-γ and IL-2 released from mouse primary spleen lymphocytes were taken as screening indices. The physical stability of eight natural compounds and the dissolubility of arctigenin, selected based on the in vitro pharnacodynamaic screening and the stability evaluation, were detected by HPLC. The in vivo pharmacodynamic confirmation of arctigenin and final latex product was evaluated with a passive cutaneous anaphylaxis (PCA) model and an allergen-specific skin response model. Nine natural compounds showed minor growth inhibition on RBL-2H3 cells and mouse primary spleen lymphocytes. Baicalin and arctigenin had the best anti-type I and IV allergic effects among the natural compounds based on the in vitro pharmacodynamic screening. Arctigenin and catechin had the best physical stability under different manufacturing conditions. Arctigenin was the selected for further evaluation and proven to have anti-type I and IV allergic effects in vivo in a dose-dependent manner. The final product of the arctigenin-containing latex glove had anti-type I and IV allergic effects in vivo which were mainly attributed to arctigenin as proved from the dissolubility results. Arctigenin showed anti-type I and IV allergic effects in vitro and in vivo, with a good stability under latex glove manufacturing conditions, and a persistent anti-allergic effect after being added into the latex to prevent latex allergy. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Bishu, Ram R.; Bronkema, Lisa
1993-01-01
Human capabilities such as dexterity, manipulability, and tactile perception are unique and render the hands as a very versatile, effective and a multipurpose tool. This is especially true for environments such as the EVA environment. However, with the use of the protective EVA gloves, there is much evidence to suggest that human performance decreases. In order to determine the nature and cause of this performance decrement, several performance tests were run which studied the effects of gloves on strength, tactile feedback, and range of motion. Tactile sensitivity was measured as a function of grip strength, and the results are discussed. Equipment which was developed to measure finger range of motion along with corresponding finger strength values is discussed. The results of these studies have useful implications for improved glove design.
On-demand tuned hazard free elastomeric composites: A green approach.
Manoharan, Partheban; Chandra Das, Narayan; Naskar, Kinsuk
2017-07-01
Rising ecological concerns and depletion of the potentially harmful environmental impacts caused by rubber products, are of prime importance in the industry. Therefore, implementation of sustainable greener materials is required to minimize the detrimental influences. In this research, we investigated the beneficial influence of naturally derived bio-resin toward the effects of association with Zinc Oxide Nanoparticles in highly dispersible silica (HDS) reinforced Natural rubber (NR)/Epoxidized Natural Rubber (ENR)-based composites. This novel green composite offers impressive properties which were analyzed based on bound rubber content, transmission electron microscopy, physico-mechanical, dynamic mechanical, and cure characteristics. Nanoindentation studies demonstrated the enhanced hysteresis phenomenon of the green composites. The small angle X-ray scattering (SAXS) characterization has been studied by using a Beaucage model and results corroborates that the insertion of bio-resin exhibits ameliorated state of silica dispersion in the green composites. Overall, the study with the bio-resin has provided the impetus in employing it as an alternative to the expensive synthetic route of silane coupling agent and toxic process oil. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Harea, Evghenii; Stoček, Radek; Storozhuk, Liudmyla; Sementsov, Yurii; Kartel, Nikolai
2018-04-01
Dry friction and wear properties of natural rubber (NR), containing multi-walled carbon nanotubes (MWCNT) and carbon black (CB), were investigated. Natural rubber (NR)-based composites containing all common additives and curatives, and a fixed amount (30 phr—parts per 100 rubber by weight) of hybrid fillers (MWCNT x + CB30-x ) were prepared by simple mixing procedure and tested. The main goal was to study the behaviours of composites at different tribological testing conditions, such as friction speed and normal load. It was found that with an increase of concentration of MWCNT from x = 0 phr to x = 5 phr in studied composites, there was a decrease in the coefficient of friction (COF) with no significant change in wear in the framework of each used combination of testing parameters. Generally, higher friction speed at certain normal force led to the increase of COF of all the samples and wear reflected deliberate value fluctuation. Also, it was established that considerable growth of wear and unexpected reducing of friction coefficient ensued from increasing of applied load for every fixed sliding speed.
40 CFR 63.6015 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... finished tire for the purpose of sealing any future hole which might occur in the tread when an object... the sum of the materials (for example, natural rubber, synthetic rubber, carbon black, oils, sulfur...
40 CFR 63.6015 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... finished tire for the purpose of sealing any future hole which might occur in the tread when an object... the sum of the materials (for example, natural rubber, synthetic rubber, carbon black, oils, sulfur...
40 CFR 63.6015 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... finished tire for the purpose of sealing any future hole which might occur in the tread when an object... the sum of the materials (for example, natural rubber, synthetic rubber, carbon black, oils, sulfur...
40 CFR 63.6015 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... finished tire for the purpose of sealing any future hole which might occur in the tread when an object... the sum of the materials (for example, natural rubber, synthetic rubber, carbon black, oils, sulfur...
Reinforcement of natural rubber latex by nanosize montmorillonite clay
NASA Astrophysics Data System (ADS)
Tantatherdtam, Rattana
Based on the unique character of montmorillonite namely its layer structure and the ability of silicate particles to separate into nanometer-size platelets, natural rubber (polyisoprene)/clay composites were obtained by mixing rubber latex with clay-water dispersion and coagulating the mixture. The resulting film had greatly improved mechanical properties compared with films using micron-sized fillers. Further, both modulus and toughness were improved; in many composite system an improvement in modulus leads to a loss of toughness. X-ray diffraction results indicated that clay platelets dispersed in the rubber matrix on the nanoscale level with some macromolecules intercalated into the clay gallery. The observed considerable improvement in mechanical properties, coupled with a theoretical model of composite modulus suggests a dispersed structure of clay in the composite. While not all clay particles are exfoliated, data suggest that a reasonable fraction of exfoliated materials is required to explain the experimental results.
Characterization of associated proteins and phospholipids in natural rubber latex.
Sansatsadeekul, Jitlada; Sakdapipanich, Jitladda; Rojruthai, Porntip
2011-06-01
Non-rubber components present in natural rubber (NR) latex, such as proteins and phospholipids, are presumed to be distributed in the serum fraction as well as surrounding the rubber particle surface. The phospholipid-protein layers covering the rubber particle surface are especially interesting due to their ability to enhance the colloidal stability of NR latex. In this study, we have characterized the components surrounding the NR particle surface and investigated their role in the colloidal stability of NR particles. Proteins from the cream fraction were proteolytically removed from the NR latex and compare to those from the serum fractions using SDS-polyacrylamide gel electrophoresis revealing that both fractions contained similar proteins in certain molecular weights such as 14.5, 25 and 27 kDa. Phospholipids removed from latex by treatment with NaOH were analyzed using (1)H-NMR spectroscopy and several major signals were assignable to -(CH(2))(n)-, -CH(2)OP, -CH(2)OC═O and -OCH(2)CH(2)NH-. These signals are important evidence that indicates phospholipids associate with the rubber chain. The colloidal behavior of rubber lattices before and after removal of protein-lipid membrane was evaluated by zeta potential analysis and scanning electron microscope (SEM). The lowest zeta potential value of NR particles was observed at pH 10, consequently leading to the highest stability of rubber particles. Additionally, SEM micrographs clearly displayed a gray ring near the particle surface corresponding to the protein-lipid membrane layer. Copyright © 2011 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Allergens in indoor air: environmental assessment and health effects.
Carrer, P; Maroni, M; Alcini, D; Cavallo, D
2001-04-10
It has been suggested that the increase in morbidity and mortality for asthma and allergies, may also be due to an increase in exposure to allergens in the modern indoor environment. Indoor allergen exposure is recognised as the most important risk factor for asthma in children. House dust mites, pets, insects, plants, moulds and chemical agents in the indoor environment are important causes of allergic diseases. House dust mites and their debris and excrements that contain the allergens are normally found in the home in beds, mattresses, pillows, carpets and furniture stuffing, but they have also been found in office environments. Domestic animals such as cats, dogs, birds and rodents may cause allergic asthma and rhinoconjunctivitis. The exposure usually occurs in homes, but also in schools and kindergartens where domestic animals are kept as pets or for education; moreover, cat and dog owners can bring allergens to public areas in their clothes. Allergy to natural rubber latex has become an important occupational health concern in recent years, particularly among healthcare workers; when powdered gloves are worn or changed, latex particles get into the air and workers are exposed to latex aerosolised antigens. To assess the environmental risk to allergen exposure or to verify if there is a causal relationship between the immunologic findings in a patient and his/her environmental exposure, sampling from the suspected environment may be necessary.
Frequency of glove perforation and the protective effect of double gloves in gynecological surgery.
Murta, Eddie F C; Silva, Cléber S; Júnior, Odilon R A
2003-06-01
The purposes of this prospective study were to verify the frequency of glove perforation during gynecological operations and to evaluate the efficacy of double gloving in preventing damage to the inner glove. From May 2000 to May 2001, three house staff and 12 residents were asked to place their used gloves in bags labeled with the following information: procedure performed, presence of a recognized glove perforation, and role in operating team (surgeon, first or second assistant, and instrumentalist). All glove sets were tested using the method of water pression. Damaged gloves were excluded from that analysis. In all, 35 and 51 operations were utilized with single and double gloves, respectively. There were 240 single gloves and 792 double gloves tested. Perforation occurred in 10.4% of the single gloves and 9.8% of the outer double gloves. There were no cases of perforation in the inner double gloves. In cases of operating time that lasted more than 2 h, 56% of the surgeries that used single gloves had perforation vs 58.5% of the double gloves. The first assistant had the major risk for glove perforation with the use of single or double gloves. The indicator finger of the non-dominant hand was the major risk for perforation. In conclusion, we recommend double gloving in all gynecological surgery to reduce the risk of contracting blood-borne diseases.
Latex allergens in tire dust and airborne particles.
Miguel, A G; Cass, G R; Weiss, J; Glovsky, M M
1996-01-01
The prevalence and severity of latex allergy has increased dramatically in the last 15 years due to exposure to natural rubber products. Although historically this health risk has been elevated in hospital personnel and patients, a recent survey has indicated a significant potential risk for the general population. To obtain a wide-spread source for latex exposure, we have considered tire debris. We have searched for the presence of latex allergens in passenger car and truck tire tread, in debris deposited from the atmosphere near a freeway, and in airborne particulate matter samples representative of the entire year 1993 at two sites in the Los Angeles basin (California). After extraction of the samples with phosphate buffered saline, a modified-ELISA inhibition assay was used to measure relative allergen potency and Western blot analyses were used to identify latex allergens. The inhibition studies with the human IgE latex assay revealed inhibition by the tire tread source samples and ambient freeway dust, as well as by control latex sap and latex glove extracts. Levels of extractable latex allergen per unit of protein extracted were about two orders of magnitude lower for tire tread as compared to latex gloves. Western blot analyses using binding of human IgE from latex-sensitive patients showed a band at 34-36 kDa in all tire and ambient samples. Long Beach and Los Angeles, California, air samples showed four additional bands between 50 and 135 kDa. Alternative Western blot analyses using rabbit IgG raised against latex proteins showed a broad band at 30-50 kDa in all samples, with additional bands in the urban air samples similar to the IgE results. A latex cross-reactive material was identified in mountain cedar. In conclusion, the latex allergens or latex cross-reactive material present in sedimented and airborne particulate material, derived from tire debris, and generated by heavy urban vehicle traffic could be important factors in producing latex allergy and asthma symptoms associated with air pollution particles. Images Figure 1. Figure 2. A Figure 2. B Figure 3. Figure 4. PMID:8959407
Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie
2017-10-01
To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P < .001) with each additional minute of surgery. Orthopedic reinforced gloves and double standard gloving were equally effective at preventing contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.
Manually operated elastomer heat pump
NASA Technical Reports Server (NTRS)
Hutchinson, W. D.
1970-01-01
Device consisting of a rotating mechanism, a frame with multiple wide bands of rubber, and a fluid bath, demonstrates the feasibility of a human operated device capable of cooling or producing heat. This invention utilizes the basic thermodynamic properties of natural rubber.
Butts, H.L.
1962-02-13
This invention comprises a housing unit to be fitted between a glove box port and a glove so that a slidable plate within the housing seals off the glove box port for evacuation of the glove box without damage to the glove. The housing and the glove may be evacuated without damage to the glove since movement of the glove is restricted during evacuation by the slidable plate. (AEC)
NASA Astrophysics Data System (ADS)
Amran, Umar Adli; Zakaria, Sarani; Chia, Chin Hua
2013-11-01
A preliminary study on the reaction between aqueous resole type resinified liquefied palm oil empty fruit bunches fibres (RLEFB) with epoxidized natural rubber (ENR). Liquefaction of empty fruit bunches (EFB) is carried out at different ratio of phenol to EFB (P:EFB). Resole type phenolic resin is prepared using sodium hydroxide (NaOH) as the catalyst with the ratio of liquefied EFB (LEFB) to formaldehyde (LEFB:F) of 1:1.8. 50% epoxidation of epoxidized natural rubber (ENR-50) is used to react with resole resin by mixing with ENR with aqueous resole resin. The cured resin is characterized with FT-IR and SEM. Aqueous system have been found to be unsuitable medium in the reaction between resin and ENR. This system produced a highly porous product when RLEFB/ENR resin is cured.
Wang, Jinchuang; Ren, Changqi; Cheng, Hanting; Zou, Yukun; Bughio, Mansoor Ahmed; Li, Qinfen
2017-10-01
Microbial communities and their associated enzyme activities affect quantity and quality of phosphorus (P) in soils. Land use change is likely to alter microbial community structure and feedback on ecosystem structure and function. This study presents a novel assessment of mechanistic links between microbial responses to land use and shifts in the amount and quality of soil phosphorus (P). We investigated effects of the conversion of rainforests into rubber agroforests (AF), young rubber (YR), and mature rubber (MR) plantations on soil P fractions (i.e., labile P, moderately labile P, occluded P, Ca P, and residual P) in Hainan Island, Southern China. Microbial community composition and microbial enzyme were assayed to assess microbial community response to forest conversion. In addition, we also identified soil P fractions that were closely related to soil microbial and chemical properties in these forests. Conversion of forest to pure rubber plantations and agroforestry system caused a negative response in soil microorganisms and activity. The bacteria phospholipid fatty acid (PLFAs) levels in young rubber, mature rubber and rubber agroforests decreased after forest conversion, while the fungal PLFAs levels did not change. Arbuscular mycorrhizal fungi (AMF) (16:1w5c) had the highest value of 0.246μmol(gOC) -1 in natural forest, followed by rubber agroforests, mature rubber and young rubber. Level of soil acid phosphatase activity declined soon (5 years) after forest conversion compared to natural forest, but it improved in mature rubber and agroforestry system. Labile P, moderately labile P, occluded P and residual P were highest in young rubber stands, while moderately labile, occluded and residual P were lowest in rubber agroforestry system. Soil P fractions such as labile P, moderately labile P, and Ca P were the most important contributors to the variation in soil microbial community composition. We also found that soil P factions differ significantly among the four transformation systems. Soil labile P faction and its potential sources (moderately labile P, occluded P, and residual P) were positively correlated with NO 3 - , but negatively correlated with AMF, suggesting that these properties play key roles in P transformation. Our study indicated that land use had an impact on microbial community composition and functions, which consequently influenced soil phosphorus availability and cycling. Copyright © 2017 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Acid soils have been reported to restrict crop growth and productivity by creating unhealthy conditions for crops including deficiencies of K, Ca, Mg, and P and toxicities of Al, Mn and Fe. The current study was conducted with natural rubber (NR, Hevea brasiliensis Mu¨ll. Arg) plantations grown on a...
Wood Sawdust/Natural Rubber Ecocomposites Cross-Linked by Electron Beam Irradiation
Manaila, Elena; Stelescu, Maria Daniela; Craciun, Gabriela; Ighigeanu, Daniel
2016-01-01
The obtaining and characterization of some polymeric eco-composites based on wood sawdust and natural rubber is presented. The natural rubber was cross-linked using the electron beam irradiation. The irradiation doses were of 75, 150, 300 and 600 kGy and the concentrations of wood sawdust were of 10 and 20 phr, respectively. As a result of wood sawdust adding, the physical and mechanical properties such as hardness, modulus at 100% elongation and tensile strength, showed significant improvements. The presence of wood sawdust fibers has a reinforcing effect on natural rubber, similar or better than of mineral fillers. An increase in the irradiation dose leads to the increasing of cross-link density, which is reflected in the improvement of hardness, modulus at 100% elongation and tensile strength of blends. The cross-linking rates, appreciated using the Flory-Rehner equation, have increased with the amount of wood sawdust in blends and with the irradiation dose. Even if the gel fraction values have varied irregularly with the amount of wood sawdust and irradiation dose it was over 90% for all blends, except for the samples without wood sawdust irradiated with 75 kGy. The water uptake increased with increasing of fiber content and decreased with the irradiation dose. PMID:28773626
NASA Astrophysics Data System (ADS)
Gao, Jiangshan; He, Yan; Gong, Xiubin
2018-06-01
The original equipment and method for orienting multi-walled carbon nanotubes (MWCNTs) in natural rubber (NR) by alternating current (AC) electric field were reported in the present study. MWCNTs with various volume fractions were dispersed in the mixture latex which composed of natural rubber, additives and methylbenzene. The application of AC electric field during nanocomposites curing process was used to induce the formation of aligned conductive nanotube networks between the electrodes. The aligned MWCNTs in the composites have a better orientation performance and dispersion quality than these of random MWCNTs by analyzing TEM and SEM images. The effects of MWCNTs anisotropy on thermal conductivity, dielectric properties, and dynamic mechanical properties of NR were studied. The mean value of thermal conductivity of composites loading with aligned MWCNTs was 8.67% higher than that of composites with random MWCNTs due to the anisotropy of aligned MWCNTs. The compounds with aligned MWCNTs possessed low dielectric constant, loss tangents and conductivity, namely a good insulativity. The compounds loading with aligned MWCNTs had lower loss modulus and better dynamic mechanical properties than those with random MWCNTs. This method can make full use of the high thermal conductivity of MWCNTs axis, and expand the application areas of natural rubber like conducting heat in a certain direction with a high efficiency.
Wood Sawdust/Natural Rubber Ecocomposites Cross-Linked by Electron Beam Irradiation.
Manaila, Elena; Stelescu, Maria Daniela; Craciun, Gabriela; Ighigeanu, Daniel
2016-06-23
The obtaining and characterization of some polymeric eco-composites based on wood sawdust and natural rubber is presented. The natural rubber was cross-linked using the electron beam irradiation. The irradiation doses were of 75, 150, 300 and 600 kGy and the concentrations of wood sawdust were of 10 and 20 phr, respectively. As a result of wood sawdust adding, the physical and mechanical properties such as hardness, modulus at 100% elongation and tensile strength, showed significant improvements. The presence of wood sawdust fibers has a reinforcing effect on natural rubber, similar or better than of mineral fillers. An increase in the irradiation dose leads to the increasing of cross-link density, which is reflected in the improvement of hardness, modulus at 100% elongation and tensile strength of blends. The cross-linking rates, appreciated using the Flory-Rehner equation, have increased with the amount of wood sawdust in blends and with the irradiation dose. Even if the gel fraction values have varied irregularly with the amount of wood sawdust and irradiation dose it was over 90% for all blends, except for the samples without wood sawdust irradiated with 75 kGy. The water uptake increased with increasing of fiber content and decreased with the irradiation dose.
NASA Astrophysics Data System (ADS)
Taer, E.; Taslim, R.; Deraman, M.
2016-02-01
Preparation of activated carbon monolith (ACM) from rubber wood was investigated. Two kind of preparation method were carried out by pre-carbonized of rubber wood saw dust and rubber wood material as it is naturally. The samples were prepared with pelletizing method and small cutting of rubber wood in cross sectional method. Both of samples were characterized by physical and electrochemical technique. The physical properties such as morphology and porosity were investigated. The electrochemical properties of both samples such as equivalent series resistances (ESR) and specific capacitances were also compared. In conclusion, this study showed that both of different preparation method would propose a simple method of ACM electrode preparation technique for supercapacitor applications.
NASA Astrophysics Data System (ADS)
Montefrio, M. F.
2012-12-01
Burgeoning attention in biofuels and natural rubber has spurred interest among governments and private companies in integrating marginalized communities into global commodity markets. Upland farmers from diverse cultural backgrounds and biophysical settings today are deciding whether to agree with partnership proposals from governments and private firms to grow biofuels and natural rubber. In this paper, I examine whether upland farmers' socio-environmental constructions (evaluative beliefs, place satisfaction, and ecological worldviews) and the actual biophysical attributes (land cover and soil types) of upland environments, respectively, function as significant predictors of the intent and decisions of indigenous and non-indigenous farmers to cooperate with government and private actors to establish certain biofuel crops and natural rubber production systems in Palawan, Philippines. Drawing from ethnography and statistical analysis of household surveys, I propose that social constructions and the biophysical attributes of the environment are closely related with each other and in turn both influence individual decision-making behavior in resource-based production partnership regimes. This has significant implications on the resilience of socio-ecological systems, particularly agro-ecosystems, as certain upland farmers prefer to engage in intensive, monocrop production of biofuels and natural rubber on relatively more biodiverse areas, such as secondary forests and traditional shifting cultivation lands. The study aims to advance new institutional theories of resource management, particularly Ostrom's Institutional Analysis and Development and Socio-Ecological Systems frameworks, and scholarship on environmental decision-making in the context of collective action.
Experimental Investigation on Damping Property of Coarse Aggregate Replaced Rubber Concrete
NASA Astrophysics Data System (ADS)
Sugapriya, P.; Ramkrishnan, R.; Keerthana, G.; Saravanamurugan, S.
2018-02-01
Rubber has good damping and vibrational characteristics and can reduce cracking significantly due to its elastic nature. This property of rubber can be incorporated in concrete to control vibrations and create better pavements. Crumb Rubber on being dumped in landfills has serious repercussions and causes soil and land pollution. An innovative use of waste tires is shredding them into small pieces and using them as a replacement for coarse aggregate. Crumb rubber is obtained by chopping scrap tires, and in this study it was added in two different sets named SET 1 - Treated Crumb Rubber and concrete, and SET 2 - Treated Crumb rubber with Ultra Fine GGBS as admixture in concrete. Coarse aggregate replaces Rubber in each of the 2 SET’s in proportions of 5, 10, 15 and 20%. Properties like Compressive Strength, Young’s Modulus, Direct and Semi direct Ultrasonic Pulse Velocity, Sorptivity, Damping ratio and Frequency were found out. Deformation and mode shape were studied with modal analysis and static analysis by applying a uniform pressure corresponding to the highest compressive strength of the slab, using ANSYS.
Wearable strain sensors based on thin graphite films for human activity monitoring
NASA Astrophysics Data System (ADS)
Saito, Takanari; Kihara, Yusuke; Shirakashi, Jun-ichi
2017-12-01
Wearable health-monitoring devices have attracted increasing attention in disease diagnosis and health assessment. In many cases, such devices have been prepared by complicated multistep procedures which result in the waste of materials and require expensive facilities. In this study, we focused on pyrolytic graphite sheet (PGS), which is a low-cost, simple, and flexible material, used as wearable devices for monitoring human activity. We investigated wearable devices based on PGSs for the observation of elbow and finger motions. The thin graphite films were fabricated by cutting small films from PGSs. The wearable devices were then made from the thin graphite films assembled on a commercially available rubber glove. The human motions could be observed using the wearable devices. Therefore, these results suggested that the wearable devices based on thin graphite films may broaden their application in cost-effective wearable electronics for the observation of human activity.
Automotive and Construction Equipment for Arctic Use, Materials Problems
1991-11-01
followed. Nitrile rubber ( NBR ) is one of the most common materials used in seal manufacture. It is a copolymer of butadiene and acrylonitrile and is... rubber and other elastomers, and many plastics. This problem is exacerbated, especially in equipment with diesel engines, because the engines run...their original condition in a short time on removal of the stress. The group includes natural rubbers as well as synthetic polymers. Many of these
Dataglove measurement of joint angles in sign language handshapes
Eccarius, Petra; Bour, Rebecca; Scheidt, Robert A.
2012-01-01
In sign language research, we understand little about articulatory factors involved in shaping phonemic boundaries or the amount (and articulatory nature) of acceptable phonetic variation between handshapes. To date, there exists no comprehensive analysis of handshape based on the quantitative measurement of joint angles during sign production. The purpose of our work is to develop a methodology for collecting and visualizing quantitative handshape data in an attempt to better understand how handshapes are produced at a phonetic level. In this pursuit, we seek to quantify the flexion and abduction angles of the finger joints using a commercial data glove (CyberGlove; Immersion Inc.). We present calibration procedures used to convert raw glove signals into joint angles. We then implement those procedures and evaluate their ability to accurately predict joint angle. Finally, we provide examples of how our recording techniques might inform current research questions. PMID:23997644
Glove perforation rate in vascular surgery--a comparison between single and double gloving.
Aarnio, P; Laine, T
2001-05-01
In surgery intact gloves act as a sterile barrier between surgeon and patient. The impermeable gloves protect the surgeon from bloodborne pathogens such as HIV, hepatitis B, and hepatitis C. On the other hand, the surgical wound is protected from micro-organisms from the skin of the surgeon. One objective of this study was to compare puncture rates between the double gloving color indication system and single-use gloves and the other to determine the extent to which glove perforations remain undetected during the course of vascular surgical operations. The study material comprised all gloves used in vascular surgical operations at Satakunta Central Hospital for a period of two months. The analysis was made by the glove type in a prospective and randomised manner. Gloves were tested immediately after the surgical procedure using the approved standardized water-leak method. With this method the glove is filled with water using a special filling tube, and the water-filled glove is then checked for two minutes to detect any holes. The gloves used in this study were either double gloves with indicator, or the standard glove used at our hospital. In 73 operations altogether 200 gloves were tested, half of them were double gloves and half were single gloves. The perforation occurred in the double gloves 3 times and with single gloves 12 times. The overall perforation rate was 15 out of 200 gloves (7.5%). The detection of perforation during surgery was 60%. Most frequently the perforation was located in the second finger of the left hand, 9 out of 15 perforations. In view of the critical importance of safety at work both transmitting the pathogens from the skin of the surgeon to the wound and transmitting the bloodborne pathogens from the patient to the surgeon, it is very important to use double gloving at least in operations where there is a high risk of glove perforation.
FTIR spectra and mechanical strength analysis of some selected rubber derivatives.
Gunasekaran, S; Natarajan, R K; Kala, A
2007-10-01
Rubber materials have wide range of commercial applications such as, infant diapers, famine hygiene products, drug delivery devices and incontinency products such as rubber tubes, tyres, etc. In the present work, studies on mechanical properties of some selected rubber materials viz., natural rubber (NR), styrene butadiene rubber (SBR), nitrile butadiene rubber (NBR) and ethylene propylene diene monomer (EPDM) have been carried out in three states viz., raw, vulcanized and reinforced. To enhance the quality of rubber elastomers, an attempt is made to prepare new elastomers called polyblends. In the present study an attempt is made to blend NR with NBR and with EPDM. We here report, a novel approach for the evaluation of various physico-mechanical properties such as mechanical strength, tensile strength, elongation and hardness. The method is simple, direct and fast and involves infrared spectral measurements for the evaluation of these properties. With the applications of modern infrared spectroscopy, the mechanical strength of these rubber materials have been analyzed by calculating the internal standards among the methyl and methylene group vibrational frequencies obtained from FTIR spectroscopy. Also the tensile strength measurements carried out by universal testing machine. The results pertaining physico-mechanical properties of the rubber derivatives undertaken in the present study obtained by IR-based method are in good agreement with data resulted from the standard methods.
FTIR spectra and mechanical strength analysis of some selected rubber derivatives
NASA Astrophysics Data System (ADS)
Gunasekaran, S.; Natarajan, R. K.; Kala, A.
2007-10-01
Rubber materials have wide range of commercial applications such as, infant diapers, famine hygiene products, drug delivery devices and incontinency products such as rubber tubes, tyres, etc. In the present work, studies on mechanical properties of some selected rubber materials viz., natural rubber (NR), styrene butadiene rubber (SBR), nitrile butadiene rubber (NBR) and ethylene propylene diene monomer (EPDM) have been carried out in three states viz., raw, vulcanized and reinforced. To enhance the quality of rubber elastomers, an attempt is made to prepare new elastomers called polyblends. In the present study an attempt is made to blend NR with NBR and with EPDM. We here report, a novel approach for the evaluation of various physico-mechanical properties such as mechanical strength, tensile strength, elongation and hardness. The method is simple, direct and fast and involves infrared spectral measurements for the evaluation of these properties. With the applications of modern infrared spectroscopy, the mechanical strength of these rubber materials have been analyzed by calculating the internal standards among the methyl and methylene group vibrational frequencies obtained from FTIR spectroscopy. Also the tensile strength measurements carried out by universal testing machine. The results pertaining physico-mechanical properties of the rubber derivatives undertaken in the present study obtained by IR-based method are in good agreement with data resulted from the standard methods.
Glove Use and Glove Education in Workers with Hand Dermatitis.
Rowley, Kyle; Ajami, Daana; Gervais, Denise; Mooney, Lindsay; Belote, Amy; Kudla, Irena; Switzer-McIntyre, Sharon; Holness, D Linn
2016-01-01
Occupational skin diseases are common. The occurrence of occupational skin diseases represents a failure of primary prevention strategies that may include the use of personal protective equipment, most commonly gloves. The objective of this study was to describe current glove use and education practices related to gloves in workers being assessed for possible work-related hand dermatitis. Participants included consecutive patients being assessed for possible work-related hand dermatitis. A self-administered questionnaire obtained information on demographics, workplace characteristics and exposures, glove use, and education regarding gloves. Ninety percent of the 105 participants reported using gloves. Only 44% had received training related to glove use in the workplace. Major gaps in training content included skin care when using gloves, warning signs of skin problems, and glove size. If the worker indicated no glove training received, the majority reported they would have used gloves if such training was provided. Although the majority of workers being assessed wore gloves, the minority had received training related to glove use. Particular gaps in training content were identified. Those who had not received training noted they would likely have used gloves if training had been provided.
Cournoyer, Michael E.; Lawton, Cindy M.; Lounsbury, James B.; ...
2016-03-22
We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate thatmore » the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E.; Lawton, Cindy M.; Lounsbury, James B.
We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate thatmore » the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.« less
Radiation degradation of spent butyl rubbers
NASA Astrophysics Data System (ADS)
Telnov, A. V.; Zavyalov, N. V.; Khokhlov, Yu. A.; Sitnikov, N. P.; Smetanin, M. L.; Tarantasov, V. P.; Shadrin, D. N.; Shorikov, I. V.; Liakumovich, A. L.; Miryasova, F. K.
2002-03-01
Radiation methods of materials modification applied in technological chains can have significant economical and ecological advantages as compared to the established chemical, thermal and mechanical methods. Each year the problems of nature resources economy through the use of production and consumption wastes acquire a more significant value, as it allows to solve also ecological issues along with economical ones. This is mostly acute in relation to polymeric systems based on saturated rubbers, for example butyl rubber (BR) used in the tyre industry, as due to their high resistance to the action of oxygen, ozone, solar radiation and bacteria, they contaminate the environment for rather a long period. At VNIIEF and KSPU experiments were carried out on application of electron beams with energy from 6 to 10 MeV for radiation destruction of spent rubber based on BR. The radiation-degraded material was tested for re-use in the formulation of initial diaphragm mixture, rubber mixture for producing rubberized fabric and roofing.
The rubber tree genome reveals new insights into rubber production and species adaptation.
Tang, Chaorong; Yang, Meng; Fang, Yongjun; Luo, Yingfeng; Gao, Shenghan; Xiao, Xiaohu; An, Zewei; Zhou, Binhui; Zhang, Bing; Tan, Xinyu; Yeang, Hoong-Yeet; Qin, Yunxia; Yang, Jianghua; Lin, Qiang; Mei, Hailiang; Montoro, Pascal; Long, Xiangyu; Qi, Jiyan; Hua, Yuwei; He, Zilong; Sun, Min; Li, Wenjie; Zeng, Xia; Cheng, Han; Liu, Ying; Yang, Jin; Tian, Weimin; Zhuang, Nansheng; Zeng, Rizhong; Li, Dejun; He, Peng; Li, Zhe; Zou, Zhi; Li, Shuangli; Li, Chenji; Wang, Jixiang; Wei, Dong; Lai, Chao-Qiang; Luo, Wei; Yu, Jun; Hu, Songnian; Huang, Huasun
2016-05-23
The Para rubber tree (Hevea brasiliensis) is an economically important tropical tree species that produces natural rubber, an essential industrial raw material. Here we present a high-quality genome assembly of this species (1.37 Gb, scaffold N50 = 1.28 Mb) that covers 93.8% of the genome (1.47 Gb) and harbours 43,792 predicted protein-coding genes. A striking expansion of the REF/SRPP (rubber elongation factor/small rubber particle protein) gene family and its divergence into several laticifer-specific isoforms seem crucial for rubber biosynthesis. The REF/SRPP family has isoforms with sizes similar to or larger than SRPP1 (204 amino acids) in 17 other plants examined, but no isoforms with similar sizes to REF1 (138 amino acids), the predominant molecular variant. A pivotal point in Hevea evolution was the emergence of REF1, which is located on the surface of large rubber particles that account for 93% of rubber in the latex (despite constituting only 6% of total rubber particles, large and small). The stringent control of ethylene synthesis under active ethylene signalling and response in laticifers resolves a longstanding mystery of ethylene stimulation in rubber production. Our study, which includes the re-sequencing of five other Hevea cultivars and extensive RNA-seq data, provides a valuable resource for functional genomics and tools for breeding elite Hevea cultivars.
1987-04-22
NASA 834, an F-14 Navy Tomcat, seen here in flight, was used at Dryden in 1986 and 1987 in a program known as the Variable-Sweep Transition Flight Experiment (VSTFE). This program explored laminar flow on variable sweep aircraft at high subsonic speeds. An F-14 aircraft was chosen as the carrier vehicle for the VSTFE program primarily because of its variable-sweep capability, Mach and Reynolds number capability, availability, and favorable wing pressure distribution. The variable sweep outer-panels of the F-14 aircraft were modified with natural laminar flow gloves to provide not only smooth surfaces but also airfoils that can produce a wide range of pressure distributions for which transition location can be determined at various flight conditions and sweep angles. Glove I, seen here installed on the upper surface of the left wing, was a "cleanup" or smoothing of the basic F-14 wing, while Glove II was designed to provide specific pressure distributions at Mach 0.7. Laminar flow research continued at Dryden with a research program on the NASA 848 F-16XL, a laminar flow experiment involving a wing-mounted panel with millions of tiny laser cut holes drawing off turbulent boundary layer air with a suction pump.
Fels, S S; Hinton, G E
1997-01-01
Glove-Talk II is a system which translates hand gestures to speech through an adaptive interface. Hand gestures are mapped continuously to ten control parameters of a parallel formant speech synthesizer. The mapping allows the hand to act as an artificial vocal tract that produces speech in real time. This gives an unlimited vocabulary in addition to direct control of fundamental frequency and volume. Currently, the best version of Glove-Talk II uses several input devices, a parallel formant speech synthesizer, and three neural networks. The gesture-to-speech task is divided into vowel and consonant production by using a gating network to weight the outputs of a vowel and a consonant neural network. The gating network and the consonant network are trained with examples from the user. The vowel network implements a fixed user-defined relationship between hand position and vowel sound and does not require any training examples from the user. Volume, fundamental frequency, and stop consonants are produced with a fixed mapping from the input devices. With Glove-Talk II, the subject can speak slowly but with far more natural sounding pitch variations than a text-to-speech synthesizer.
NASA Astrophysics Data System (ADS)
Pradeep, B.; Meti, S.; James, J.
2014-11-01
Most parts of the traditional natural rubber growing regions of India, extending from Kanyakumari district of Tamil Nadu in the South to Kasaragod district of Kerala in the North received excess and prolonged rains during 2013. This led to severe incidence of Abnormal Leaf Fall (ALF) disease caused by the fungus, Phytophthora sp. The present study demonstrated the first time use of satellite remote sensing technique to monitor ALF disease by estimating Leaf Area Index (LAI) in natural rubber holdings in near real time. Leaf retention was monitored in between April and December 2012 and 2013 by estimating LAI using MODIS 15A2 product covering rubber holdings spread across all districts in the traditional rubber growing region of the country that was mapped using Resourcesat LISS III 2012 and 2013 data. It was found that as the monsoon advanced, LAI decreased substantially in both years, but the reduction was much more substantial and prolonged in many districts during 2013 than 2012 reflecting increased leaf fall due to ALF disease in 2013. The decline was more pronounced in central and northern Kerala than in the South. Kanyakumari district of Tamil Nadu is generally known to be free from ALF disease, but there was considerable leaf loss due to ALF in June 2012 and June and July 2013 even as the monsoon was unusually severe in 2013. Weighted mean LAI during for the entire period of April to December was estimated as a weighted average of LAI and per cent of total area under rubber in each district in the study area for the two years. This was markedly less in 2013 than 2012. The implications of poor leaf retention for biomass production (net primary productivity), carbon sequestration and rubber yield are discussed.
Preparation and Characterization of Natural Rubber/Organophilic Clay Nanocomposites
NASA Astrophysics Data System (ADS)
Gonzales-Fernandes, M.; Esper, F. J.; Silva-Valenzuela, M. G.; Martín-Cortés, G. R.; Valenzuela-Diaz, F. R.; Wiebeck, H.
Natural rubber/organophilic clay nanocomposites were prepared and characterized. A brown bentonite from Paraiba's State, Brazil was modified with a sodium salt and treated with quaternary ammonium salt hexadecyltrimethyl ammonium chloride. The clay in its natural state, after cation exchange with sodium and after organophilization was characterized by XRD, IR, SEM, thermal analysis. Nanocomposite samples were prepared containing 10 resin percent of organophilic clay. The vulcanized samples were analyzed by XRD, SEM. The nanocomposites obtained showed improvement in their mechanical properties in comparison with samples without clay.
75 FR 38468 - Procurement List; Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-02
...: 8415-00-NIB-0810--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Small. NSN: 8415-00-NIB-0811--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Medium. NSN: 8415-00-NIB-0812--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Large. NSN: 8415-00-NIB-0813--Glove, Vinyl...
Effect of epoxidation on 30% poly(methyl methacrylate)-grafted natural rubber polymer electrolytes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazir, Khuzaimah; Aziz, Ahmad Fairoz; Adam, Nurul Ilham
Epoxidized 30% poly(methyl methacrylate)-grafted natural rubber (EMG 30) as a polymer host in solid polymer electrolytes (SPEs) has been investigated. EMG30 was synthesized via performicepoxidation method onto 30% poly(methyl methacrylate)-grafted natural rubber (MG30) and the formations of epoxy group were discussed. The EMG30 were characterized by proton nuclear magnetic resonance ({sup 1}HNMR) to investigate their chemical structure and differential scanning calorimeter to determine their crystallinity. A new peak in {sup 1}HNMR spectra (2.71 ppm) confirmed the appearance of epoxy group. SPE based on EMG30 doped with 40 wt% LiCF{sub 3}SO{sub 3} show the highest conductivity. The complexation between EMG30 and LiCF{submore » 3}SO{sub 3} were confirmed by attenuated total reflection Fourier transform infrared (ATR-FTIR)« less
Analytical network-averaging of the tube model: Strain-induced crystallization in natural rubber
NASA Astrophysics Data System (ADS)
Khiêm, Vu Ngoc; Itskov, Mikhail
2018-07-01
In this contribution, we extend the analytical network-averaging concept (Khiêm and Itskov, 2016) to phase transition during strain-induced crystallization of natural rubber. To this end, a physically-based constitutive model describing the nonisothermal strain-induced crystallization is proposed. Accordingly, the spatial arrangement of polymer subnetworks is driven by crystallization nucleation and consequently alters the mesoscopic deformation measures. The crystallization growth is elucidated by diffusion of chain segments into crystal nuclei. The crystallization results in a change of temperature and an evolution of heat source. By this means, not only the crystallization kinetics but also the Gough-Joule effect are thoroughly described. The predictive capability of the constitutive model is illustrated by comparison with experimental data for natural rubbers undergoing strain-induced crystallization. All measurable values such as stress, crystallinity and heat source are utilized for the comparison.
NASA Astrophysics Data System (ADS)
de Siqueira, A. F.; Cabrera, F. C.; Pagamisse, A.; Job, A. E.
2014-12-01
This study consolidates multi-level starlet segmentation (MLSS) and multi-level starlet optimal segmentation (MLSOS) techniques for photomicrograph segmentation, based on starlet wavelet detail levels to separate areas of interest in an input image. Several segmentation levels can be obtained using MLSS; after that, Matthews correlation coefficient is used to choose an optimal segmentation level, giving rise to MLSOS. In this paper, MLSOS is employed to estimate the concentration of gold nanoparticles with diameter around 47 nm, reduced on natural rubber membranes. These samples were used for the construction of SERS/SERRS substrates and in the study of the influence of natural rubber membranes with incorporated gold nanoparticles on the physiology of Leishmania braziliensis. Precision, recall, and accuracy are used to evaluate the segmentation performance, and MLSOS presents an accuracy greater than 88 % for this application.
Epoxidized Natural Rubber/Chitosan Network Binder for Silicon Anode in Lithium-Ion Battery.
Lee, Sang Ha; Lee, Jeong Hun; Nam, Dong Ho; Cho, Misuk; Kim, Jaehoon; Chanthad, Chalathorn; Lee, Youngkwan
2018-05-16
Polymeric binder is extremely important for Si-based anode in lithium-ion batteries due to large volume variation during charging/discharging process. Here, natural rubber-incorporated chitosan networks were designed as a binder material to obtain both adhesion and elasticity. Chitosan could strongly anchor Si particles through hydrogen bonding, while the natural rubber could stretch reversibly during the volume variation of Si particles, resulting in high cyclic performance. The prepared electrode exhibited the specific capacities of 1350 mAh/g after 1600 cycles at the current density of 8 A/g and 2310 mAh/g after 500 cycles at the current density of 1 A/g. Furthermore, the cycle test with limiting lithiation capacity was conducted to study the optimal binder properties at varying degree of the volume expansion of silicon, and it was found that the elastic property of binder material was strongly required when the large volume expansion of Si occurred.
Performance Analysis of Exam Gloves Used for Aseptic Rodent Surgery
LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie
2015-01-01
Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP–PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham ‘exertion’ activity. According to these criteria, 94% of HP–PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP–PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries. PMID:26045458
Performance analysis of exam gloves used for aseptic rodent surgery.
LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie
2015-05-01
Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.
Nielsen, Jesper Bo; Sørensen, Jens Ahm
2012-02-15
Protective gloves are used to reduce dermal exposure when managing chemical exposures at the work place. Different glove materials may offer different degrees of protection. The present study combined the traditional ASTM (American Society for Testing and Materials) model with the Franz diffusion cell to evaluate overall penetration through glove and skin as well as the deposition in the different reservoirs. Benzoic acid was applied on latex or nitrile gloves placed on top of human skin. The amounts of chemical were quantified in the glove material, between glove and skin, within the skin, and in the receptor chamber. Both glove materials reduce total penetration of benzoic acid, but nitrile gloves offer a significantly better protection than latex gloves. This difference was less pronounced at the higher of the two concentrations of benzoic acid applied. Thus, glove types that offer relevant protection at low concentrations does not necessarily give appropriate protection at high concentrations. Significant amounts of benzoic acid could be extracted from the glove materials after exposure. If a chemical is accumulated in the glove material, reuse of single-use gloves should be cautioned. The reuse of gloves is generally not to be recommended without effective decontamination. Copyright © 2011 Elsevier B.V. All rights reserved.
Novel Slide-Ring Material/Natural Rubber Composites with High Damping Property
Wang, Wencai; Zhao, Detao; Yang, Jingna; Nishi, Toshio; Ito, Kohzo; Zhao, Xiuying; Zhang, Liqun
2016-01-01
A novel class of polymers called “slide-ring” (SR) materials with slideable junctions were used for high damping composites for the first time. The SR acts as the high damping phase dispersed in the natural rubber (NR) matrix, and epoxidized natural rubber (ENR) acts as the compatibilizer. The morphological, structural, and mechanical properties of the composites were investigated by atomic force microscope (AFM), transmission electron microscope (TEM), dynamic mechanical thermal analyzer (DMTA), rubber processing analyzer (RPA), and tensile tester. AFM and TEM results showed that the SR phase was uniformly dispersed in the composites, in a small size that is a function of ENR. DMTA and RPA results showed that the damping factor of the composites is much higher than that of NR, especially at room temperatures. Stretch hysteresis was used to study the energy dissipation of the composites at large strains. The results showed that SR and ENR can significantly improve the dissipation efficiency at strains lower than 200% strain. Wide-angle X-ray diffraction was used to study the strain-induced crystallization of the composites. The results indicated that the impact of the SR on the crystallization of NR is mitigated by the insulating effect of ENR. PMID:26949077
Xu, Chuanhui; Cao, Liming; Huang, Xunhui; Chen, Yukun; Lin, Baofeng; Fu, Lihua
2017-08-30
In most cases, the strength of self-healing supramolecular rubber based on noncovalent bonds is in the order of KPa, which is a challenge for their further applications. Incorporation of conventional fillers can effectively enhance the strength of rubbers, but usually accompanied by a sacrifice of self-healing capability due to that the filler system is independent of the reversible supramolecular network. In the present work, in situ reaction of methacrylic acid (MAA) and excess zinc oxide (ZnO) was realized in natural rubber (NR). Ionic cross-links in NR matrix were obtained by limiting the covalent cross-linking of NR molecules and allowing the in situ polymerization of MAA/ZnO. Because of the natural affinity between Zn 2+ ion-rich domains and ZnO, the residual nano ZnO participated in formation of a reversible ionic supramolecular hybrid network, thus having little obstructions on the reconstruction of ionic cross-links. Meanwhile, the well dispersed residual ZnO could tailor the mechanical properties of NR by changing the MAA/ZnO molar ratios. The present study thus provides a simple method to fabricate a new self-healing NR with tailorable mechanical properties that may have more potential applications.
Cross Contamination: Are Hospital Gloves Reservoirs for Nosocomial Infections?
Moran, Vicki; Heuertz, Rita
2017-01-01
Use of disposable nonsterile gloves in the hospital setting is second only to proper hand washing in reducing contamination during patient contact. Because proper handwashing is not consistently practiced, added emphasis on glove use is warranted. There is a growing body of evidence that glove boxes and dispensers available to healthcare workers are contaminated by daily exposure to environmental organisms. This finding, in conjunction with new and emerging antibiotic-resistant bacteria, poses a threat to patients and healthcare workers alike. A newly designed glove dispenser may reduce contamination of disposable gloves. The authors investigated contamination of nonsterile examination gloves in an Emergency Department setting according to the type of dispenser used to access gloves. A statistically significant difference existed between the number of bacterial colonies and the type of dispenser: the downward-facing glove dispenser had a lower number of bacteria on the gloves. There was no statistically significant difference in the number of gloves contaminated between the two types of glove dispensers. The study demonstrated that contamination of disposable gloves existed. Additional research using a larger sample size would validate a difference in the contamination of disposable gloves using outward or downward glove dispensers.
Autonomic self-healing in epoxidized natural rubber.
Rahman, Arifur; Sartore, Luciana; Bignotti, Fabio; Di Landro, Luca
2013-02-01
The development of polymers that can repair damage autonomously would be useful to improve the lifetime of polymeric materials. To date, limited attention has been dedicated to developing elastomers with autonomic self-healing ability, which can recover damages without need for an external or internal source of healing agents. This work investigates the self-healing behavior of epoxidized natural rubber (ENR) with two different epoxidation levels (25 and 50 mol % epoxidation) and of the corresponding unfunctionalized rubber, cis-1,4-polyisoprene (PISP). A self-adhesion assisted self-healing behavior was revealed by T-peel tests on slightly vulcanized rubbers. A higher epoxidation level was found to enhance self-healing. Self-healing of rubbers following ballistic damages was also investigated. A pressurized air flow test setup was used to evaluate the self-healing of ballistic damages in rubbers. Microscope (OM, SEM, and TEM) analyses were carried out to provide further evidence of healing in the impact zones. Self-healing of ballistic damages was observed only in ENR with 50 mol % epoxidation and it was found to be influenced significantly by the cross-link density. Finally, self-healing of ballistic damages was also observed in ENR50/PISP blends only when the content of the healing component (i.e., ENR50) was at least 25 wt %. From an analysis of the results, it was concluded that a synergistic effect between interdiffusion and interaction among polar groups leads to self-healing in ENR.
75 FR 22744 - Procurement List: Proposed Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
..., Industrial/Non-Medical Grade, 100 Gloves/Box, Small. NSN: 8415-00-NIB-0811--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Medium. NSN: 8415-00-NIB-0812--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves/Box, Large. NSN: 8415-00-NIB-0813--Glove, Vinyl, Industrial/Non-Medical Grade, 100 Gloves...
EV space suit gloves (passive)
NASA Technical Reports Server (NTRS)
Fletcher, E. G.; Dodson, J. D.; Elkins, W.; Tickner, E. G.
1975-01-01
A pair of pressure and thermal insulating overgloves to be used with an Extravehicular (EV) suit assembly was designed, developed, fabricated, and tested. The design features extensive use of Nomex felt materials in lieu of the multiple layer insulation formerly used with the Apollo thermal glove. The glove theoretically satisfies all of the thermal requirements. The presence of the thermal glove does not degrade pressure glove tactility by more than the acceptable 10% value. On the other hand, the thermal glove generally degrades pressure glove mobility by more than the acceptable 10% value, primarily in the area of the fingers. Life cycling tests were completed with minimal problems. The thermal glove/pressure glove ensemble was also tested for comfort; the test subjects found no problems with the thermal glove although they did report difficulties with pressure points on the pressure glove which were independent of the thermal glove.
Analysis of cold-acclimated guayule transcriptome
USDA-ARS?s Scientific Manuscript database
The perennial shrub commonly know as guayule (Partheniun argentatum), native of the Chihuahuan desert, is a rubber producing plant currently being develop as a domestic source of high quality natural rubber essential for the manufacturing of several consumer products for which the use of synthetic r...
NASA Astrophysics Data System (ADS)
Fan, Lili; Wang, Guoping; Wang, Wenju; Shi, Guanxin; Yang, Fufeng; Rui, Xiaoting
2018-04-01
Various anisotropic magnetorheological elastomers (MREs) were synthesized using the rubber mixing technique. Magnetic and temperature distributions of the experimental equipment and test instruments were analyzed by the ANSYS. NH4HCO3 was filled in the natural rubber matrix to modify properties of MREs. Microstructures and compositions of samples were studied by the scanning electron microscope (SEM), the energy dispersive x-ray spectroscopy (EDAX) analysis and x-ray powder diffraction (XRD). Via vibrating sample magnetometer (VSM) and density functional theory (DFT) method, the magnetic property of carbonyl iron (CI) was illuminated. The shear storage modulus and MR effect of MREs were investigated by the dynamic mechanical analyzer (DMA). It indicated that distributions of magnetic and temperature in the experimental and testing devices were uniform. Before vulcanization, CI particles were uniformly distributed in the matrix, while a CI chain structure was formed and embedded in the matrix after the vulcanization process. Moderate addition of NH4HCO3 accelerated the rubber vulcanization and enhanced the MR effect.
Makita, Yuko; Kawashima, Mika; Lau, Nyok Sean; Othman, Ahmad Sofiman; Matsui, Minami
2018-01-19
Natural rubber is an economically important material. Currently the Pará rubber tree, Hevea brasiliensis is the main commercial source. Little is known about rubber biosynthesis at the molecular level. Next-generation sequencing (NGS) technologies brought draft genomes of three rubber cultivars and a variety of RNA sequencing (RNA-seq) data. However, no current genome or transcriptome databases (DB) are organized by gene. A gene-oriented database is a valuable support for rubber research. Based on our original draft genome sequence of H. brasiliensis RRIM600, we constructed a rubber tree genome and transcriptome DB. Our DB provides genome information including gene functional annotations and multi-transcriptome data of RNA-seq, full-length cDNAs including PacBio Isoform sequencing (Iso-Seq), ESTs and genome wide transcription start sites (TSSs) derived from CAGE technology. Using our original and publically available RNA-seq data, we calculated co-expressed genes for identifying functionally related gene sets and/or genes regulated by the same transcription factor (TF). Users can access multi-transcriptome data through both a gene-oriented web page and a genome browser. For the gene searching system, we provide keyword search, sequence homology search and gene expression search; users can also select their expression threshold easily. The rubber genome and transcriptome DB provides rubber tree genome sequence and multi-transcriptomics data. This DB is useful for comprehensive understanding of the rubber transcriptome. This will assist both industrial and academic researchers for rubber and economically important close relatives such as R. communis, M. esculenta and J. curcas. The Rubber Transcriptome DB release 2017.03 is accessible at http://matsui-lab.riken.jp/rubber/ .
Can the design of glove dispensing boxes influence glove contamination?
Assadian, O; Leaper, D J; Kramer, A; Ousey, K J
2016-11-01
Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which single gloves are dispensed vertically, cuff end first, has lower levels of contamination on the gloves and on the surface around the box aperture compared with conventional glove boxes. Seven participating sites were provided with vertical glove dispensing systems (modified boxes) and conventional boxes. Before opening glove boxes, the surface around the aperture was sampled microbiologically to establish baseline levels of superficial contamination. Once the glove boxes were opened, the first pair of gloves in each box was sampled for viable bacteria. Thereafter, testing sites were visited on a weekly basis over a period of six weeks and the same microbiological assessments were made. The surface near the aperture of the modified boxes became significantly less contaminated over time compared with the conventional boxes (P<0.001), with an average of 46.7% less contamination around the aperture. Overall, gloves from modified boxes showed significantly less colony-forming unit contamination than gloves from conventional boxes (P<0.001). Comparing all sites over the entire six-week period, gloves from modified boxes had 88.9% less bacterial contamination. This simple improvement to glove box design reduces contamination of unused gloves. Such modifications could decrease the risk of microbial cross-transmission in settings that use gloves. However, such advantages do not substitute for strict hand hygiene compliance and appropriate use of non-sterile, single-use gloves. Copyright © 2016 The Healthcare Infection Society. All rights reserved.
Mantello, Camila Campos; Cardoso-Silva, Claudio Benicio; da Silva, Carla Cristina; de Souza, Livia Moura; Scaloppi Junior, Erivaldo José; de Souza Gonçalves, Paulo; Vicentini, Renato; de Souza, Anete Pereira
2014-01-01
Hevea brasiliensis (Willd. Ex Adr. Juss.) Muell.-Arg. is the primary source of natural rubber that is native to the Amazon rainforest. The singular properties of natural rubber make it superior to and competitive with synthetic rubber for use in several applications. Here, we performed RNA sequencing (RNA-seq) of H. brasiliensis bark on the Illumina GAIIx platform, which generated 179,326,804 raw reads on the Illumina GAIIx platform. A total of 50,384 contigs that were over 400 bp in size were obtained and subjected to further analyses. A similarity search against the non-redundant (nr) protein database returned 32,018 (63%) positive BLASTx hits. The transcriptome analysis was annotated using the clusters of orthologous groups (COG), gene ontology (GO), Kyoto Encyclopedia of Genes and Genomes (KEGG), and Pfam databases. A search for putative molecular marker was performed to identify simple sequence repeats (SSRs) and single nucleotide polymorphisms (SNPs). In total, 17,927 SSRs and 404,114 SNPs were detected. Finally, we selected sequences that were identified as belonging to the mevalonate (MVA) and 2-C-methyl-D-erythritol 4-phosphate (MEP) pathways, which are involved in rubber biosynthesis, to validate the SNP markers. A total of 78 SNPs were validated in 36 genotypes of H. brasiliensis. This new dataset represents a powerful information source for rubber tree bark genes and will be an important tool for the development of microsatellites and SNP markers for use in future genetic analyses such as genetic linkage mapping, quantitative trait loci identification, investigations of linkage disequilibrium and marker-assisted selection.
Mobility of the elastic counterpressure space suit glove.
Tanaka, Kunihiko; Danaher, Patrick; Webb, Paul; Hargens, Alan R
2009-10-01
To evaluate the mobility of the current gas-pressurized glove of the extravehicular mobility unit (G-glove) and the elastic counterpressure glove (E-glove), we investigated range of motion (ROM) and indices of fatigue during grip endurance with both gloves using a bare hand as a control. In nine healthy male right-handed subjects, ROM of the proximal interphalangeal joint of the left middle finger was measured. The median frequency of electromyography (EMG) of the left flexor carpi radialis during grip with 25% of maximum strength was measured with the bare hand, G-glove, and E-glove. Using Borg's scale, discomfort was assessed during each grip test. ROM of the E-glove was similar to that of the bare hand (91 +/- 3 degrees and 97 +/- 1 degree for the E-glove and bare hand, respectively) and significantly higher than that of the G-glove (74 +/- 2 degrees). The change in the median frequency of the EMG, which is correlated with Borg's scale, was significantly smaller using the E-glove at marker time points of 1/4 and 1/2 of the total endurance time (-3.5 +/- 1.5 and -10.4 +/- 1.2 Hz) compared to those for the G-glove (-10.1 +/- 1.1 and -16.7 +/- 1.9 Hz). Thus, the G-glove had faster onset of fatigue than the E-glove. These results suggest the E-glove has better mobility and is more suitable for fine motor tasks as compared to the G-glove.
Natural Forest Biomass Estimation Based on Plantation Information Using PALSAR Data
Avtar, Ram; Suzuki, Rikie; Sawada, Haruo
2014-01-01
Forests play a vital role in terrestrial carbon cycling; therefore, monitoring forest biomass at local to global scales has become a challenging issue in the context of climate change. In this study, we investigated the backscattering properties of Advanced Land Observing Satellite (ALOS) Phased Array L-band Synthetic Aperture Radar (PALSAR) data in cashew and rubber plantation areas of Cambodia. The PALSAR backscattering coefficient (σ0) had different responses in the two plantation types because of differences in biophysical parameters. The PALSAR σ0 showed a higher correlation with field-based measurements and lower saturation in cashew plants compared with rubber plants. Multiple linear regression (MLR) models based on field-based biomass of cashew (C-MLR) and rubber (R-MLR) plants with PALSAR σ0 were created. These MLR models were used to estimate natural forest biomass in Cambodia. The cashew plant-based MLR model (C-MLR) produced better results than the rubber plant-based MLR model (R-MLR). The C-MLR-estimated natural forest biomass was validated using forest inventory data for natural forests in Cambodia. The validation results showed a strong correlation (R2 = 0.64) between C-MLR-estimated natural forest biomass and field-based biomass, with RMSE = 23.2 Mg/ha in deciduous forests. In high-biomass regions, such as dense evergreen forests, this model had a weaker correlation because of the high biomass and the multiple-story tree structure of evergreen forests, which caused saturation of the PALSAR signal. PMID:24465908
Glove perforation in hip and knee arthroplasty.
Demircay, Emre; Unay, Koray; Bilgili, Mustafa G; Alataca, Gulum
2010-11-01
The transmission of blood-borne pathogens during surgery is a major concern. Surgical gloves are the primary barrier between the surgeon and the patient. Surgical procedures that need manual handling of bony surfaces or sharp instruments have the highest risk of glove perforations. The frequencies and the sites of surgical glove perforations in arthroplasty procedures were assessed. We assessed the surgical glove perforations in total hip and knee arthroplasty procedures. Double standard latex gloves were used. A total of 983 outer and 511 inner gloves were tested. The gloves of all the surgical team members were tested for perforations during the first and second hours of surgery. There were 18.4% outer and 8.4% inner glove perforations. The most frequent site of perforation was the second digit of the nondominant hand (25.5%). We found that hip and knee arthroplasty had significantly more glove perforation risk for the surgeon in the first half of the operation rather than the second half, and 57.8% of the perforations were at the index finger and the thumb. Arthroplasty procedures still have high glove perforation rates despite the use of double gloving with frequent changes. Extra augmentation of the gloves in selected areas of the hand, in addition to double gloving, may be safer and more cost-effective than double gloving alone.
Prospective randomized assessment of single versus double-gloving for general surgical procedures.
Na'aya, H U; Madziga, A G; Eni, U E
2009-01-01
There is increased tendency towards double-gloving by general surgeons in our practice, due probably to awareness of the risk of contamination with blood or other body fluids during surgery. The aim of the study was to compare the relative frequency of glove puncture in single-glove versus double glove sets in general surgical procedures, and to determine if duration of surgery affects perforation rate. Surgeons at random do single or double gloves at their discretion, for general surgical procedures. All the gloves used by the surgeons were assessed immediately after surgery for perforation. A total of 1120 gloves were tested, of which 880 were double-glove sets and 240 single-glove sets. There was no significant difference in the overall perforation rate between single and double glove sets (18.3% versus 20%). However, only 2.3% had perforations in both the outer and inner gloves in the double glove group. Therefore, there was significantly greater risk for blood-skin exposure in the single glove sets (p < 0.01). The perforation rate was also significantly greater during procedures lasting an hour or more compared to those lasting less than an hour (p < 0.01). Double-gloving reduces the risk of blood-skin contamination in all general surgical procedures, and especially so in procedures lasting an hour or more.
Xie, Jin; Li, Zhao-Li; Li, Yong-Mei; Guo, Fang-Fang
2011-12-01
Eighty-six topsoil (0-20 cm) samples were collected from 8 land use types (natural forest land, maize field, tea garden, paddy field, rubber plantation, flax field, banana plantation, and sugarcane field) in the Naban River Watershed National Nature Reserve and its surrounding areas, and the soil physical and chemical properties were analyzed, aimed to study the effects of land use type on the soil quality by the method of soil quality index (SQI). Comparing with natural forest land, all the cultivated lands had somewhat decreased soil organic matter content and higher soil bulk density, and the soil bulk density was significantly higher in tea garden, paddy field, rubber plantation, and banana plantation. In cultivated lands, fertilization and reclamation made the soil available potassium and phosphorus contents maintained at a higher level, probably due to the input of mineral potassium and phosphorus and the decomposition of soil organic matter. The SQI of the 8 land use types was in the order of flax field (0.595) > natural forest land (0.532) > maize field (0.516) > banana plantation (0.485) tea garden (0.480) sugarcane field (0.463) > paddy field (0.416) > rubber plantation (0.362). The soils in higher altitude production demonstration areas (1614 +/-115 m) had significant higher SQI, compared to the soils in lower altitude buffer areas (908 +/- 98 m) and junction areas (926 +/- 131 m). Among the 8 land use types, the rubber plantation in lower altitude areas had the lowest SQI, due to the lower soil organic matter and available potassium and phosphorus contents and the highest soil bulk density. Application of organic manure or intercropping with leguminous plants could be an available practice to improve the soil quality of the rubber plantation.
Sung, Peng-Cheng
2014-01-01
This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.
Glove utilization in the prevention of cross transmission: a systematic review.
Picheansanthian, Wilawan; Chotibang, Jutamas
2015-05-15
Gloves are worn to protect hands from contamination from microorganisms and to reduce the risks of transmission of microorganisms from healthcare workers to patients and vice versa. However, gloves should be changed between patient contacts and hand washing is necessary before putting on gloves and immediately after removing gloves. The objective of this review was to evaluate and synthesize the best available research evidence that investigates clinical use of gloves in the prevention of cross transmission. Health care workers.Types of intervention(s): Glove use intervention. Types of outcomes: Contamination of healthcare workers' hands, transmission of infections, adherence to glove usage, inappropriate uses of gloves, and adherence to hand hygiene. Types of studies: Quasi-experimental studies and descriptive studies. The search sought to find published and unpublished studies. The time period of the search covered articles published from 2000 to 2012 in English and Thai. The databases searched included: MEDLINE, CINAHL, EMBASE, The Cochrane Library, PubMed, Science Direct, Current Content Connect, Blackwell synergy, Thai Nursing Research Database, Thai thesis database, Digital Library of Thailand Research Fund, Research of National Research Council of Thailand, and Database of Office of Higher Education. Studies selected for retrieval were assessed by two independent reviewers for methodological quality using the Joanna Briggs Institute Meta-Analysis of Statistics Assessment and Review Instrument software. Data extraction was performed using the standardized data extraction tool from the Joanna Briggs Institute Meta-Analysis of Statistics Assessment and Review Instrument software. A meta-synthesis was not possible due to the methodological heterogeneity of the included papers. The evidence was thus presented as a narrative summary. Twenty-three studies were included in this review. The results indicated that contamination of a healthcare worker's gloves with bacteria during routine care activities is common. The use of gloves can protect the hands of healthcare workers from bacterial contamination, but the protection afforded by the gloves was incomplete. Adherence to glove utilization among healthcare workers was suboptimal. Gloves were overused and often misused. The major break in compliance with glove use was failure to change gloves between procedures on the same patient. Inappropriate glove use can increase the risk of cross transmission. It is unclear if modifications in glove use alter compliance with hand hygiene among healthcare workers. Gloving can reduce acquisition of microorganisms on the hands. However, gloving does not completely prevent contamination of the hands. Compliance with glove use among healthcare workers is poor. Gloves were also overused and often misused. Inappropriate glove use can increase the risk of cross transmission via contaminated gloved hands. There is still not enough evidence to prove the influence of glove use on adherence to hand hygiene. This review strengthens the recent suggestion on the use of gloves to reduce bacterial contamination. However, gloving does not completely prevent contamination, thus emphasizing the need for hand antisepsis before and after patient contact. Intervention to improve the use of gloves and hand hygiene compliance after gloving in the healthcare settings should be implemented. Further studies should target poor compliers with glove use and promote strategies that can be evaluated. The Joanna Briggs Institute.
Watari, Takahiro; Cuong Mai, Trung; Tanikawa, Daisuke; Hirakata, Yuga; Hatamoto, Masashi; Syutsubo, Kazuaki; Fukuda, Masao; Nguyen, Ngoc Bich; Yamaguchi, Takashi
2017-01-01
Conventional aerated tank technology is widely applied for post treatment of natural rubber processing wastewater in Southeast Asia; however, a long hydraulic retention time (HRT) is required and the effluent standards are exceeded. In this study, a downflow hanging sponge (DHS) reactor was installed as post treatment of anaerobic tank effluent in a natural rubber factory in South Vietnam and the process performance was evaluated. The DHS reactor demonstrated removal efficiencies of 64.2 ± 7.5% and 55.3 ± 19.2% for total chemical oxygen demand (COD) and total nitrogen, respectively, with an organic loading rate of 0.97 ± 0.03 kg-COD m -3 day -1 and a nitrogen loading rate of 0.57 ± 0.21 kg-N m -3 day -1 . 16S rRNA gene sequencing analysis of the sludge retained in the DHS also corresponded to the result of reactor performance, and both nitrifying and denitrifying bacteria were detected in the sponge carrier. In addition, anammox bacteria was found in the retained sludge. The DHS reactor reduced the HRT of 30 days to 4.8 h compared with the existing algal tank. This result indicates that the DHS reactor could be an appropriate post treatment for the existing anaerobic tank for natural rubber processing wastewater treatment.
Fricke, Julia; Hillebrand, Andrea; Twyman, Richard M; Prüfer, Dirk; Schulze Gronover, Christian
2013-04-01
Natural rubber is a high-molecular-mass biopolymer found in the latex of >2,500 plant species, including Hevea brasiliensis, Parthenium argentatum and Taraxacum spp. The active sites of rubber biosynthesis are rubber particles, which comprise a hydrophobic rubber core surrounded by a phospholipid monolayer membrane containing species-dependent lipids and associated proteins. Small rubber particle proteins are the most abundant rubber particle-associated proteins in Taraxacum brevicorniculatum (TbSRPPs) and may promote rubber biosynthesis by stabilizing the rubber particle architecture. We investigated the transcriptional regulation of genes encoding SRPPs and identified a bZIP transcription factor (TbbZIP.1) similar to the Arabidopsis thaliana ABI5-ABF-AREB subfamily, which is thought to include downstream targets of ABA and/or abiotic stress-inducible protein kinases. The TbbZIP.1 gene was predominantly expressed in laticifers and regulates the expression of TbSRPP genes in an ABA-dependent manner. The individual TbSRPP genes showed distinct induction profiles, suggesting diverse roles in rubber biosynthesis and stress adaptation. The potential involvement of TbSRPPs in the adaptation of T. brevicorniculatum plants to environmental stress is discussed based on our current knowledge of the stress-response roles of SRPPs and their homologs, and the protective function of latex and rubber against pathogens. Our data suggest that TbSRPPs contribute to stress tolerance in T. brevicorniculatum and that their effects are mediated by TbbZIP.1.
Improved Gloves for Firefighters
NASA Technical Reports Server (NTRS)
Tschirch, R. P.; Sidman, K. R.; Arons, I. J.
1983-01-01
New firefighter's gloves are more flexible and comfortable than previous designs. Since some firefighters prefer gloves made of composite materials while others prefer dip-coated gloves, both types were developed. New gloves also find uses in foundries, steelmills, and other plants where they are substituted for asbestos gloves.
The mechanical and microbiological integrity of surgical gloves.
Jamal, Ala; Wilkinson, Stephen
2003-03-01
Several manufacturers supply surgical gloves that have been individually tested (IT) for leaks. Other manufacturers supply gloves in which sample gloves from each batch are tested for leaks (batch tested: BT). The latter brands may be rejected by surgeons because of presumed increased risk of wound infection and staff exposure to patient pathogens. The influence of differences between glove brands on performance in surgery has not been extensively studied. The aims of the present study were to test the mechanical and microbiological integrity of IT compared to BT gloves. A total of 110 unused gloves from each of an IT and a BT brand were tested for leaks, first, by observation of water-jets from water-filled gloves and second, by measuring electrical resistance between inside and outside the glove surfaces, to give a baseline measure. A total of 304 IT and 280 BT gloves were then similarly leak-tested after 98 clean surgical procedures. The hands and gloves of scrub team members were cultured postsurgery. A total of 1/110 BT and 0/110 IT unused gloves contained leaks (NS, Fisher's exact test). Operative perforation rates were lower for BT compared with IT (8/280 cf. 22/304; P < 0.05 Fisher's exact test). There was no bias in types of operations or scrub team members to account for the difference. Growth of normal skin flora was found on virtually every wearer's hands post-operatively. Similar bacteria were frequently cultured from the outside of gloves at the conclusion of surgery (111/152 pairs IT cf. 122/140 pairs BT; P < 0.01, Fisher's exact test). This study provides evidence that the clinical performance of BT gloves is no different to IT gloves. There was no significant difference in mechanical leak rates for unused gloves. Paradoxically, although IT gloves were more likely to show macro-perforations after surgery, the incidence of contamination on the surface of BT gloves was greater, possibly reflecting a qualitative difference in glove material. This study suggests that both types of gloves develop microporosity during use, which may allow transfer of bacteria from the surgeon's skin to the surface of the glove.
NASA Astrophysics Data System (ADS)
Indrajati, I. N.; Dewi, I. R.
2017-07-01
The objective of this study was to evaluate the performance of maleated castor oil (MACO) as plasticizer on natural rubber (NR), ethylene propylene diene monomer (EPDM), and nitrile butadiene rubber (NBR). The parameter studied were involving rheological, curing and swelling properties. The MACOs were prepared by an esterification reaction between castor oil (CO) and maleic anhydride (MAH) with the help of xylene as water entrainer to improve water removal. Resulting oils then applied as a plasticizer in each of those rubbers within a fixed loading of 5 phr. Comparison has been made to evaluate the performance of MACO and conventional plasticizer (paraffinic oil for NR and EPDM, DOP for NBR) on each rubber. Rheology, curing characteristic and swelling of each rubber were studied. The results showed that rubber (NR/EPDM/NBR) plasticized with MACO had given similar flow characteristic to conventional plasticizers. MACO exhibited slow curing, confirmed by higher t90, but the scorch safety was of the same magnitude. MAH loading tended to decrease the flow properties and curing rate, while scorch time (ts2) was independent.
Yamashita, Satoshi; Yamaguchi, Haruhiko; Waki, Toshiyuki; Aoki, Yuichi; Mizuno, Makie; Yanbe, Fumihiro; Ishii, Tomoki; Funaki, Ayuta; Tozawa, Yuzuru; Miyagi-Inoue, Yukino; Fushihara, Kazuhisa; Nakayama, Toru; Takahashi, Seiji
2016-01-01
Natural rubber (NR) is stored in latex as rubber particles (RPs), rubber molecules surrounded by a lipid monolayer. Rubber transferase (RTase), the enzyme responsible for NR biosynthesis, is believed to be a member of the cis-prenyltransferase (cPT) family. However, none of the recombinant cPTs have shown RTase activity independently. We show that HRT1, a cPT from Heveabrasiliensis, exhibits distinct RTase activity in vitro only when it is introduced on detergent-washed HeveaRPs (WRPs) by a cell-free translation-coupled system. Using this system, a heterologous cPT from Lactucasativa also exhibited RTase activity, indicating proper introduction of cPT on RP is the key to reconstitute active RTase. RP proteomics and interaction network analyses revealed the formation of the protein complex consisting of HRT1, rubber elongation factor (REF) and HRT1-REF BRIDGING PROTEIN. The RTase activity enhancement observed for the complex assembled on WRPs indicates the HRT1-containing complex functions as the NR biosynthetic machinery. DOI: http://dx.doi.org/10.7554/eLife.19022.001 PMID:27790974
F-111 natural laminar flow glove flight test data analysis and boundary layer stability analysis
NASA Technical Reports Server (NTRS)
Runyan, L. J.; Navran, B. H.; Rozendaal, R. A.
1984-01-01
An analysis of 34 selected flight test data cases from a NASA flight program incorporating a natural laminar flow airfoil into partial wing gloves on the F-111 TACT airplane is given. This analysis determined the measured location of transition from laminar to turbulent flow. The report also contains the results of a boundary layer stability analysis of 25 of the selected cases in which the crossflow (C-F) and Tollmien-Schlichting (T-S) disturbance amplification factors are correlated with the measured transition location. The chord Reynolds numbers for these cases ranges from about 23 million to 29 million, the Mach numbers ranged from 0.80 to 0.85, and the glove leading-edge sweep angles ranged from 9 deg to 25 deg. Results indicate that the maximum extent of laminar flow varies from 56% chord to 9-deg sweep on the upper surface, and from 51% chord at 16-deg sweep to 6% chord at 25-deg sweep on the lower. The results of the boundary layer stability analysis indicate that when both C-F and T-S disturbances are amplified, an interaction takes place which reduces the maximum amplification factor of either type of disturbance that can be tolerated without causing transition.
Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning
NASA Technical Reports Server (NTRS)
Sovinski, Marjorie F.
2004-01-01
Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.
Incidence of glove failure during orthopedic operations and the protective effect of double gloves.
Thanni, Lateef O A; Yinusa, W
2003-12-01
To determine the usefulness of double gloves in protecting against the exposure of surgical team members' hands to blood. Five-hundred-ninety-six gloves were studied during 71 orthopedic operations using the water-loading test (filling a glove with water and occluding its cuff tightly to identify leaking points). In all, 73 glove perforations occurred, but only nine resulted in exposure to blood (blood touching the skin). The incidence of glove perforation was 12% (73/596), and overall exposure (blood touching the skin) per operation was 13% (9/71). The latter would have been 87% (62/71) but for the use of double gloves. Sixteen percent of the perforations in double gloves were in the inner gloves, while 84% were in the outer gloves. Exposure of surgeons was reduced from 54% to 10%, first assistants from 27% to 3%, and second assistants from 7% to 0 (p < 0.02, df = 2) by double-gloving. Significantly more perforations occurred during operations on bone, compared with soft tissue operations, p < 0.0001, RR = 4 (95% CL 1.87-8.55). The most common sites of glove perforation were the index finger (47%), thumb, and the palm region: 14% each. More glove perforations occurred in nondominant hands. Double-gloving offers additional protection to surgeons and assistants by preventing hand exposure to blood intraoperatively.
Phalen, Robert N; Le, Thi; Wong, Weng Kee
2014-01-01
Glove movement can affect chemical permeation of organic compounds through polymer glove products. However, conflicting reports make it difficult to compare the effects of movement on chemical permeation through commonly available glove types. The aim of this study was to evaluate the effect of movement on chemical permeation of an organic solvent through disposable latex, nitrile, and vinyl gloves. Simulated whole-glove permeation testing was conducted using ethyl alcohol and a previously designed permeation test system. With exposure to movement, a significant decrease (p ≤ 0.001) in breakthrough time (BT) was observed for the latex (-23%) and nitrile gloves (-31%). With exposure to movement, only the nitrile glove exhibited a significant increase (p ≤ 0.001) in steady-state permeation rate (+47%) and cumulative permeation at 30 min (+111%). Even though the nitrile glove provided optimum chemical resistance against ethyl alcohol, it was most affected by movement. With exposure to movement, the latex glove was an equivalent option for overall worker protection, because it was less affected by movement and the permeation rate was lower than that of the nitrile glove. In contrast, the vinyl glove was the least affected by movement, but did not provide adequate chemical resistance to ethyl alcohol in comparison with the nitrile and latex gloves. Glove selection should take movement and polymer type into account. Some glove polymer types are less affected by movement, most notably the latex glove in this test. With nitrile gloves, at least a factor of three should be used when attempting to assign a protection factor when repetitive hand motions are anticipated. Ultimately, the latex gloves outperformed nitrile and vinyl in these tests, which evaluated the effect of movement on chemical permeation. Future research should aim to resolve some of the observed discrepancies in test results with latex and vinyl gloves.
Phalen, Robert N.; Le, Thi; Wong, Weng Kee
2014-01-01
Glove movement can affect chemical permeation of organic compounds through polymer glove products. However, conflicting reports make it difficult to compare the effects of movement on chemical permeation through commonly available glove types. This study was aimed to evaluate the effect of movement on chemical permeation of an organic solvent through disposable latex, nitrile, and vinyl gloves. Simulated whole-glove permeation testing was conducted using ethyl alcohol and a previously designed permeation test system. With exposure to movement, a significant decrease (p ≤ 0.001) in breakthrough time was observed for the latex (-23%) and nitrile gloves (-31%). With exposure to movement, only the nitrile glove exhibited a significant increase (p ≤ 0.001) in steady-state permeation rate (+47%) and cumulative permeation at 30 min (+111%). Even though the nitrile glove provided optimum chemical resistance against ethyl alcohol, it was most affected by movement. With exposure to movement, the latex glove was an equivalent option for overall worker protection, because it was less affected by movement and the permeation rate was lower than that of the nitrile glove. In contrast, the vinyl glove was the least affected by movement, but did not provide adequate chemical resistance to ethyl alcohol in comparison with the nitrile and latex gloves. In conclusion, glove selection should take movement and polymer type into account. Some glove polymer types are less affected by movement, most notably the latex glove in this test. With nitrile gloves, at least a factor of three should be used when attempting to assign a protection factor when repetitive hand motions are anticipated. Ultimately, the latex gloves outperformed nitrile and vinyl in these tests, which evaluated the effect of movement on chemical permeation. Future research should aim to resolve some of the observed discrepancies in test results with latex and vinyl gloves. PMID:24689368
Electron linear accelerator system for natural rubber vulcanization
NASA Astrophysics Data System (ADS)
Rimjaem, S.; Kongmon, E.; Rhodes, M. W.; Saisut, J.; Thongbai, C.
2017-09-01
Development of an electron accelerator system, beam diagnostic instruments, an irradiation apparatus and electron beam processing methodology for natural rubber vulcanization is underway at the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The project is carried out with the aims to improve the qualities of natural rubber products. The system consists of a DC thermionic electron gun, 5-cell standing-wave radio-frequency (RF) linear accelerator (linac) with side-coupling cavities and an electron beam irradiation apparatus. This system is used to produce electron beams with an adjustable energy between 0.5 and 4 MeV and a pulse current of 10-100 mA at a pulse repetition rate of 20-400 Hz. An average absorbed dose between 160 and 640 Gy is expected to be archived for 4 MeV electron beam when the accelerator is operated at 400 Hz. The research activities focus firstly on assembling of the accelerator system, study on accelerator properties and electron beam dynamic simulations. The resonant frequency of the RF linac in π/2 operating mode is 2996.82 MHz for the operating temperature of 35 °C. The beam dynamic simulations were conducted by using the code ASTRA. Simulation results suggest that electron beams with an average energy of 4.002 MeV can be obtained when the linac accelerating gradient is 41.7 MV/m. The rms transverse beam size and normalized rms transverse emittance at the linac exit are 0.91 mm and 10.48 π mm·mrad, respectively. This information can then be used as the input data for Monte Carlo simulations to estimate the electron beam penetration depth and dose distribution in the natural rubber latex. The study results from this research will be used to define optimal conditions for natural rubber vulcanization with different electron beam energies and doses. This is very useful for development of future practical industrial accelerator units.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuntanoo, K., E-mail: thip-kk@hotmail.com; Promkotra, S., E-mail: sarunya@kku.ac.th; Kaewkannetra, P., E-mail: paknar@kku.ac.th
A biopolymer of polyhydroxybutyrate-co-hydroxyvalerate (PHBV) is blended with bio-based materials, natural rubber latex, to improve their microstructures. The various ratios between PHBV and natural rubber latex are examined to develop their mechanical properties. In general, physical properties of PHBV are hard, brittle and low flexible while natural rubber (NR) is presented itself as high elastic materials. Concentrations of the PHBV solution are constituted at 1%, 2% and 3% (w/v). The mixtures of their PHBV solutions to natural rubber latex are produced the blended films in three different ratios of 4:6, 5:5 and 6:4, respectively. They are characterized by appearance analysesmore » which are the scanning electron microscope (SEM), universal testing machine (UTM) and differential scanning calorimetry (DSC). The SEM photomicrographs of the blended films and the controlled PHBV can provide the void distribution in the range of 12-14% and 19-21%, respectively. For mechanical properties of the blended films, the various elastic moduli of 1%, 2% and 3% (w/v) PHBV are the average of 773, 956 and 1,007 kPa, respectively. The tensile strengths of the blends increase with the increased concentrations of PHBV, similarly trend to the elastic modulus. The crystallization and melting behavior of unmixed PHBV and the blends are determined by DSC. Melting transition temperatures (T{sub m}) of the unmixed PHBV are stated two melting peak at 154°C and 173°C. Besides, the melting peaks of the blends alter in the range of 152-156°C and 168-171°C, respectively. According to morphology of the blends, the void distribution decreases twice compared to the unmixed PHBV. The results of mechanical properties and thermal analysis indicate that the blended PHBV can be developed their properties by more resilient and wide range of temperature than usual.« less
A Model of Thermal Aging of Hyper-Elastic Materials with an Application to Natural Rubber
NASA Astrophysics Data System (ADS)
Korba, Ahmed G.
Understanding the degradation of material properties and stress-strain behavior of rubber-like materials that has been exposed to elevated temperature is essential for rubber among components design and lifetime prediction. The complexity of the relationship between hyper-elastic materials, crosslinking density, and chemical composition present a difficult problem for the accurate prediction of mechanical properties under thermal aging. In the first part of the current research, a new and relatively simple mathematical formulation is presented to expresses the change in material properties of natural rubber subjected to various elevated temperatures and aging times. The aging temperatures ranged from 76.7 °C to 115.0 °C, and the aging times ranged from 0 to 600 hours. Based on the experimental data, the natural rubber mechanical properties under thermal aging showed a similar behavior to the rate of change of the crosslinking density (CLD) with aging time and temperature as determined as of the research. Three mechanical properties have been chosen to be studied: the ultimate tensile strength, the fracture stretch value, and the secant modulus at 11.0% strain. The proposed phenomenological model relates the mechanical properties with the rate of change of the CLD based on a form of Arrhenius equation. The proposed equations showed promising results compared to the experimental data with an acceptable error margin of less than 10% in most of the cases studied. In the second part of the current research, a closed form set of equations that was based on basic continuum mechanics assumptions has been proposed to define the material stress-strain behavior of natural rubber as an application of hyper-elastic materials. The proposed formulas include the influence of aging time and temperature. The newly proposed "Wight Function Based" (WFB) method has been verified against the historic Treloar's test data for uni-axial, bi-axial and pure shear loadings of Treloar's vulcanized rubber material, showing a promising level of confidence compared to the Ogden and the Yeoh methods. Tensile testing was performed on strip specimens that were thermally aged then subjected uni-axial tension and hardness tests. A non-linear least square optimization tool in Matlab (Lscurvefitt) was used for all fitting purposes.
The guayule plant : a renewable, domestic source of binder materials for flexible pavement mixtures.
DOT National Transportation Integrated Search
2013-01-01
The guayule (pronounced 'why-YOU-lee') plant grows in arid and semi-arid regions (e.g. the southwestern U.S.) and is a source of natural rubber. It was cultivated and processed during the World War II rubber shortage and is currently being processed ...
HIGH-PERFORMANCE STEREOSPECIFIC ELASTOMERS FROM BIOREACTORS
USDA-ARS?s Scientific Manuscript database
In 2008, 10 million tons of natural rubber, cis-1,4-polyisoprene, will be produced for commercial use. Every molecule of that product will be produced in a microscopic bioreactor known as the rubber particle. These particles, suspended in an aqueous phase called latex, evolved to produce and store n...
Rapid Field Measurement of Rubber Content in Russian Dandelion
USDA-ARS?s Scientific Manuscript database
Natural rubber is a critical and strategic raw material for industrial manufacturing and national defense. In 2008, 10 million tons of NR were produced for commercial use, most of it from Hevea brasiliensis in tropical countries. The annual US import deficit for NR is approximately $1 billion. Devel...
USDA-ARS?s Scientific Manuscript database
Gauyaule (Parthenium argentatum Gray) originated in the Southern Texas and northern Mexico deserts, which suggests it as a good candidate for arid and semi-arid sustainable agricultural systems to produce natural rubber and industrial byproducts. Continued improvement of guayule for higher biomass, ...
Fructan reduction by downregulation of 1-SST in guayule
USDA-ARS?s Scientific Manuscript database
The natural rubber producing plant Parthenium argentatum (guayule) stores carbohydrates mainly in the form of fructans, which are synthesized and stored in the same tissues at the same time as the rubber polymer. The first committed step to fructan synthesis is catalyzed by sucrose:sucrose-1-fructos...
40 CFR 428.71 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fabricated Rubber Plants Subcategory § 428.71 Specialized definitions. For the purpose of this subpart: (a... natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in the manufacture... divided by the total volume of air scrubbed. (d) The term “large-sized plants” shall mean plants which...
40 CFR 428.71 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.71 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “large-sized plants” shall...
40 CFR 428.51 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fabricated Rubber Plants Subcategory § 428.51 Specialized definitions. For the purpose of this subpart: (a... natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in the manufacture... divided by the total volume of air scrubbed. (d) The term “small-sized plants” shall mean plants which...
40 CFR 428.51 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.51 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “small-sized plants” shall...
40 CFR 428.51 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fabricated Rubber Plants Subcategory § 428.51 Specialized definitions. For the purpose of this subpart: (a... natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in the manufacture... divided by the total volume of air scrubbed. (d) The term “small-sized plants” shall mean plants which...
40 CFR 428.61 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fabricated Rubber Plants Subcategory § 428.61 Specialized definitions. For the purpose of this subpart: (a... natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in the manufacture... divided by the total volume of air scrubbed. (d) The term “medium-sized plants” shall mean plants which...
40 CFR 428.51 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.51 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “small-sized plants” shall...
40 CFR 428.61 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.61 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “medium-sized plants” shall...
40 CFR 428.51 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.51 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “small-sized plants” shall...
40 CFR 428.61 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.61 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “medium-sized plants” shall...
40 CFR 428.71 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.71 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “large-sized plants” shall...
40 CFR 428.71 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.71 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “large-sized plants” shall...
40 CFR 428.61 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Extruded, and Fabricated Rubber Plants Subcategory § 428.61 Specialized definitions. For the purpose of...” shall mean all natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in... wet scrubbers divided by the total volume of air scrubbed. (d) The term “medium-sized plants” shall...
40 CFR 428.61 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fabricated Rubber Plants Subcategory § 428.61 Specialized definitions. For the purpose of this subpart: (a... natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in the manufacture... divided by the total volume of air scrubbed. (d) The term “medium-sized plants” shall mean plants which...
40 CFR 428.71 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fabricated Rubber Plants Subcategory § 428.71 Specialized definitions. For the purpose of this subpart: (a... natural and synthetic rubber, carbon black, oils, chemical compounds, and fabric used in the manufacture... divided by the total volume of air scrubbed. (d) The term “large-sized plants” shall mean plants which...
A novel method of assessing the effectiveness of protective gloves--results from a pilot study.
Creely, K S; Cherrie, J W
2001-03-01
We have devised a novel method for evaluating the effectiveness of protective gloves and have undertaken a small study to assess this approach. Three types of glove were tested in a standardised simulation test with a permethrin-based pesticide. Prewashed cotton gloves were used to collect the samples. One was worn over the protective glove on one hand to measure the potential deposition of pesticide on the hands had the gloves not been worn. A second was placed under the protective glove on the opposite hand to measure the actual deposition of permethrin on the hands when the gloves were worn. This regime was reversed half way through each test in an attempt to prevent bias. Measurable inner glove contamination occurred on 25 out of 30 occasions. Geometric mean protection factors were calculated from the ratio of outer and inner sampling glove contamination, with average protection factors of 470, 200 and 96 being obtained for the two nitrile and PVC gloves, respectively. The PVC gloves were the least effective in preventing inner glove contamination, probably because the glove was thick and fairly inflexible, causing more pesticide to enter the glove around the cuff. Although the tasks were standardised, variability occurred due to worker behaviour and equipment failure. The spray pump failed on five occasions, resulting in higher levels of inner glove contamination and a geometric mean protection factor of 32. On the occasions when the pump worked correctly, the level of protection provided by the gloves rose dramatically with mean protection factors of 220 and 450 being obtained for workers categorised as "messy" and "tidy", respectively.
Characterization of recycled rubber media for hydrogen sulphide (H2S) control.
Wang, Ning; Park, Jaeyoung; Evans, Eric A; Ellis, Timothy G
2014-01-01
Hydrogen sulphide (H2S) adsorption capacities on recycled rubber media, tyre-derived rubber particle (TDRP), and other rubber material (ORM) have been evaluated. As part of the research, densities, moisture contents, and surface properties of TDRP and ORM have been determined. The research team findings show that TDRP and ORM are more particulate in nature and not highly porous-like activated carbon. The characteristics of surface area, pore size, and moisture content support chemisorption on the macrosurface rather than physical adsorption in micropores. For example, moisture content is essential for H2S adsorption on ORM, and an increase in moisture content results in an increase in adsorption capacity.
Shearman, Jeremy R; Sangsrakru, Duangjai; Ruang-Areerate, Panthita; Sonthirod, Chutima; Uthaipaisanwong, Pichahpuk; Yoocha, Thippawan; Poopear, Supannee; Theerawattanasuk, Kanikar; Tragoonrung, Somvong; Tangphatsornruang, Sithichoke
2014-02-10
The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility.
NASA Astrophysics Data System (ADS)
El Labban, A.; Mousseau, P.; Bailleul, J. L.; Deterre, R.
2007-04-01
Although numerical simulation has proved to be a useful tool to predict the rubber vulcanization process, few applications in the process control have been reported. Because the end-use rubber properties depend on the state of cure distribution in the parts thickness, the prediction of the optimal distribution remains a challenge for the rubber industry. The analysis of the vulcanization process requires the determination of the thermal behavior of the material and the cure kinetics. A nonisothermal vulcanization model with nonisothermal induction time is used in this numerical study. Numerical results are obtained for natural rubber (NR) thick-section part curing. A controlled gradient of the state of cure in the part thickness is obtained by a curing process that consists not only in mold heating phase, but also a forced convection mold cooling phase in order to stop the vulcanization process and to control the vulcanization distribution. The mold design that allows this control is described. In the heating phase, the state of cure is mainly controlled by the chemical kinetics (the induction time), but in the cooling phase, it is the heat diffusion that controls the state of cure distribution. A comparison among different cooling conditions is shown and a good state of cure gradient control is obtained.
Tarachiwin, Lucksanaporn; Sakdapipanich, Jitladda; Ute, Koichi; Kitayama, Tatsuki; Bamba, Takashi; Fukusaki, Ei-Ichiro; Kobayashi, Akio; Tanaka, Yasuyuki
2005-01-01
Deproteinized natural rubber latex (DPNR-latex) was treated with lipase and phosphatase in order to analyze the structure of the chain-end group (alpha-terminal). The enzymatic treatment decreased the content of long-chain fatty acid ester groups in DPNR from about 6 to 2 mol per rubber molecule. The molecular weight and intrinsic viscosity were reduced to about one-third after treatment with lipase and phosphatase. The Huggins' k' constant of the enzyme-treated DPNR showed the formation of linear rubber molecules. The molecular weight distribution of DPNR changed apparently after treatment with lipase and phosphatase. (1)H NMR spectrum of rubber obtained from DPNR-latex showed small signals due to monophosphate, di-phosphate and phospholipids at the alpha-terminus. Treatment of DPNR-latex with lipase and phosphatase decreased the relative intensity of the (1)H NMR signals corresponding to phospholipids, whereas no change was observed for the signals due to mono- and diphosphates. The residual mono- and diphosphate signals as well as some phospholipid signals after lipase and phosphatase treatments indicate that mono- and diphosphate groups are directly linked at the alpha-terminus with the modified structure, expected by aggregation or linking with phospholipid molecules.
Mantello, Camila Campos; Cardoso-Silva, Claudio Benicio; da Silva, Carla Cristina; de Souza, Livia Moura; Scaloppi Junior, Erivaldo José; de Souza Gonçalves, Paulo; Vicentini, Renato; de Souza, Anete Pereira
2014-01-01
Hevea brasiliensis (Willd. Ex Adr. Juss.) Muell.-Arg. is the primary source of natural rubber that is native to the Amazon rainforest. The singular properties of natural rubber make it superior to and competitive with synthetic rubber for use in several applications. Here, we performed RNA sequencing (RNA-seq) of H. brasiliensis bark on the Illumina GAIIx platform, which generated 179,326,804 raw reads on the Illumina GAIIx platform. A total of 50,384 contigs that were over 400 bp in size were obtained and subjected to further analyses. A similarity search against the non-redundant (nr) protein database returned 32,018 (63%) positive BLASTx hits. The transcriptome analysis was annotated using the clusters of orthologous groups (COG), gene ontology (GO), Kyoto Encyclopedia of Genes and Genomes (KEGG), and Pfam databases. A search for putative molecular marker was performed to identify simple sequence repeats (SSRs) and single nucleotide polymorphisms (SNPs). In total, 17,927 SSRs and 404,114 SNPs were detected. Finally, we selected sequences that were identified as belonging to the mevalonate (MVA) and 2-C-methyl-D-erythritol 4-phosphate (MEP) pathways, which are involved in rubber biosynthesis, to validate the SNP markers. A total of 78 SNPs were validated in 36 genotypes of H. brasiliensis. This new dataset represents a powerful information source for rubber tree bark genes and will be an important tool for the development of microsatellites and SNP markers for use in future genetic analyses such as genetic linkage mapping, quantitative trait loci identification, investigations of linkage disequilibrium and marker-assisted selection. PMID:25048025
NASA Astrophysics Data System (ADS)
Bonicelli, Alessandra; Fuentes, Luis G.; Khalil Dawd Bermejo, Ibrahim
2017-10-01
Pervious concrete pavement is a recognized sustainable solution for urban roads. To enhance mechanical properties of pervious concrete material, in order to allow wider use of this technology, a lot of studies are going on all over the world. The use of a little percentage of fine aggregates is proven to increase the material resistance without an excessive reduction of permeability. This study aimed to evaluate the effect of replacing the fine virgin aggregates with r cycled tire rubber. 14 different mixes were analysed in terms of indirect tensile strength resistance, void content and density. Two different dimensions of crumb rubber were studied, as well as two different dosages, which were applied to different no-fine control mixes. All results were compared with the same control mixes containing natural fine aggregate. The mixes had a fixed granulometric curve but varied in water/cement ratio; this in order to evaluate the effect of recycled rubber depending to w/c ratio of the mix. An image analysis was also conducted to verify the rubber distribution in the mixture and the cracking surfaces. The experimental analysis showed that a correct proportioning of fine sand significantly increased the strength of the material. Moreover, the use of recycled waste tire rubber, gave interesting improvements respect to the no-fine control mixes, even though the developed resistance was lower respect to mixes containing mineral sand. This result was expected because of the cementing property of mineral sand. Although, the important result was that it was possible to use waste tire rubber in pervious concrete, with an appropriate dosage and granular dimension, for increasing the performance of traditional mix design, in order to achieve pavement materials more and more sustainable.
Wang, Na; Zhang, Miao; Kang, Ping; Zhang, Jing; Fang, Qinghong; Li, Wenda
2018-06-13
Aiming to improve the flame retardancy performance of natural rubber (NR), we developed a novel flame retardant synergistic agent through grafting of MCM-41 to graphene oxide (GO), named as GO-NH-MCM-41, as an assistant to intumescent flame retardants (IFR). The flame retardancy of NR/IFR/GO-NH-MCM-41 composites was evaluated by limited oxygen index (LOI), UL-94, and cone calorimeter test. The LOI value of NR/IFR/GO-NH-MCM-41 reached 26.3%; the UL-94 ratings improved to a V-0 rating. Moreover, the addition of GO-NH-MCM-41 decreased the peak heat release rate (PHRR) and the total heat release (THR) of the natural rubber composites. Furthermore, the addition of GO-NH-MCM-41 increased the thickness of char residue. The images of SEM indicated the char residue was more compact and continuous. The degradation of GO-NH-MCM-41-based NR composites was completed with a mass loss of 35.57% at 600 °C. The tensile strength and the elongation at break of the NR/IFR/GO-NH-MCM-41 composites were 13.9 MPa and 496.7%, respectively. The results of the rubber process analyzer (RPA) reached the maximum value, probably due to a better network of fillers in the matrix.
NASA Technical Reports Server (NTRS)
Reid, Christopher; Benson, Elizabeth; England, Scott; Charvat, Jacqueline; Norcross, Jason; McFarland, Shane; Rajulu, Sudhakar
2014-01-01
From the time hand-intensive tasks were first created for EVAs, discomforts and injuries have been noted.. There have been numerous versions of EVA gloves for US crew over the past 50 years, yet pain and injuries persist. The investigation team was tasked with assisting in a glove injury assessment for the High Performance EVA Glove (HPEG) project.center dot To aid in this assessment, the team was asked to complete the following objectives: - First, to develop the best current understanding of what glove-related injuries have occurred to date, and when possible, identify the specific mechanisms that caused those injuries - Second, to create a standardized method for comparison of glove injury potential from one glove to another. center dot The overall goal of the gloved hand injury assessment is to utilize ergonomics in understanding how these glove injuries are occurring, and to propose mitigations to current designs or design changes in the next generation of EVA gloves.
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2001-01-01
Neoprene gloves are used in a Space Shuttle Microgravity Glove Box (MGBX) experiment. In 1999, significant corrosion was observed in the work area and on the outer surface of the left glove ring. Analysis of the corrosion products showed that they contained chlorine. The Neoprene gloves used in this glove box were obtained in 1995, with a recommended shelf life of 3 years. After storage of these gloves in a cabinet drawer until 1999, significant signs of corrosion were also observed in the drawer. Mechanical and thermal properties were determined on samples cut from the finger and sleeve areas of the "good" and "bad" gloves. This data showed significant aging of the left-hand glove, particularly in the sleeve area. Thermal analysis data by DSC and TGA was complimentary to tensile data in showing this aging. However, this test data did not pinpoint the cause of the left-hand glove aging, or of the corrosion products.
Optimizing skin protection with semipermeable gloves.
Wulfhorst, Britta; Schwanitz, Hans Joachim; Bock, Meike
2004-12-01
Occlusion due to gloves is one important cause of glove irritation. Macerated softened skin gives poor protection against microbes and chemical injuries. The introduction of a breathable protective glove material would represent a significant step toward improved prevention of occupational skin disease. Performance levels of semipermeable and occlusive gloves were examined under conditions typical of the hairdressing profession. In two studies, tests comparing breathable semipermeable gloves to single-use gloves made of occlusive materials were conducted. In an initial study, a user survey was carried out in conjunction with bioengineering examinations. Values at baseline and values after gloves were worn were recorded by measuring transepidermal water loss (TEWL), skin humidity (SH), and skin surface hydrogen ion concentration (pH) in 20 healthy volunteers. In a second study, the gloves were tested for penetrability and permeability with three chemical compounds typically used in the hairdressing profession. Bioengineering examination objectively confirmed users' reports of reduced hand perspiration when semipermeable gloves were worn. The TEWL, SH, and skin surface pH values remained largely stable after 20 minutes of wearing semipermeable gloves, in contrast to the reactions observed with gloves of occlusive materials. Permeability tests indicated that the semipermeable material is effective, with some restrictions. Air leakage testing revealed that all 50 gloves tested were not airtight. Following the optimization of manufacturing methods, additional tests of the penetrability of semipermeable gloves will be necessary.
Pronk, A; Yu, F; Vlaanderen, J; Tielemans, E; Preller, L; Bobeldijk, I; Deddens, J A; Latza, U; Baur, X; Heederik, D
2006-01-01
Objectives To study inhalation and dermal exposure to hexamethylene diisocyanate (HDI) and its oligomers as well as personal protection equipment (PPE) use during task performance in conjunction with urinary hexamethylene diamine (HDA) in car body repair shop workers and industrial spray painters. Methods Personal task based inhalation samples (n = 95) were collected from six car body repair shops and five industrial painting companies using impingers with di‐n‐butylamine (DBA) in toluene. In parallel, dermal exposure was assessed using nitril rubber gloves. Gloves were submerged into DBA in toluene after sampling. Analysis for HDI and its oligomers was performed by LC‐MS/MS. Urine samples were collected from 55 workers (n = 291) and analysed for HDA by GC‐MS. Results Inhalation exposure was strongly associated with tasks during which aerosolisation occurs. Dermal exposure occurred during tasks that involve direct handling of paint. In car body repair shops associations were found between detectable dermal exposure and glove use (odds ratio (OR) 0.22, 95% confidence interval (CI) 0.09 to 0.57) and inhalation exposure level (OR 1.34, 95% CI 0.97 to 1.84 for a 10‐fold increase). HDA in urine could be demonstrated in 36% and 10% of car body repair shop workers and industrial painting company workers respectively. In car body repair shops, the frequency of detectable HDA was significantly elevated at the end of the working day (OR 2.13, 95% CI 1.07 to 4.22 for 3–6 pm v 0–8 am). In both branches HDA was detected in urine of ∼25% of the spray painters. In addition HDA was detected in urine of a large proportion of non‐spray painters in car body repair shops. Conclusion Although (spray) painting with lacquers containing isocyanate hardeners results in the highest external exposures to HDI and oligomers, workers that do not perform paint related tasks may also receive a considerable internal dose. PMID:16728504
Pressure wave injuries to rat dorsal root ganglion cells in culture caused by high-energy missiles.
Suneson, A; Hansson, H A; Lycke, E; Seeman, T
1989-01-01
A high-energy missile impact in an extremity of an animal creates a shock wave which is rapidly dispersed as a burst of oscillating pressure waves that traverses the entire body causing local, regional, and distant injuries. The present study was performed on dorsal root ganglion (DRG) cells, cultured for 3 weeks, to elucidate the cellular mechanism for damage of nerve cells, using a simplified test system. A model system was developed allowing exposure of DRG cultures to a burst of high-frequency oscillating pressure waves, comparable to those recorded in animals after high-energy missile extremity impact. The pressure waves were induced by impact of a high-energy missile in a rubber tube filled with water, in which nerve cell cultures were kept in a closed rubber glove filled with tissue culture medium. The pressure waves had a duration of 0.5-1.5 ms and a frequency spectrum ranging from 0-250 kHz. Within minutes the neurites showed changes in their microtubules. In addition, varicosities, enriched with tubulin immunoreactive material, became irregularly studded along the nerve cell processes. Scattered DRG cells were initially permeable to the marker complex Evans-blue albumin (EBA), used as an indicator of the ability of the plasma membranes to exclude proteins. After 6 hr, however, almost every DRG neuron was intensely stained by EBA. Concomitantly, there was swelling of the nerve cell cytoplasm and organelles, and, to a variable extent, neurofilament tangles were observed.(ABSTRACT TRUNCATED AT 250 WORDS)
Reliability and performance of innovative surgical double-glove hole puncture indication systems.
Edlich, Richard F; Wind, Tyler C; Heather, Cynthia L; Thacker, John G
2003-01-01
During operative procedures, operating room personnel wear sterile surgical gloves designed to protect them and their patients against transmissible infections. The Food and Drug Administration (FDA) has set compliance policy guides for manufacturers of gloves. The FDA allows surgeons' gloves whose leakage defect rates do not exceed 1.5 acceptable quality level (AQL) to be used in operating rooms. The implications of this policy are potentially enormous to operating room personnel and patients. This unacceptable risk to the personnel and patient could be significantly reduced by the use of sterile double surgical gloves. Because double-gloves are also susceptible to needle puncture, a double-glove hole indication system is urgently needed to immediately detect surgical needle glove punctures. This warning would allow surgeons to remove the double-gloves, wash their hands, and then don a sterile set of double-gloves with an indication system. During the last decade, Regent Medical has devised non-latex and latex double-glove hole puncture indication systems. The purpose of this comprehensive study is to detect the accuracy of the non-latex and latex double-glove hole puncture indication systems using five commonly used sterile surgical needles: the taper point surgical needle, tapercut surgical needle, reverse cutting edge surgical needle, taper cardiopoint surgical needle, and spatula surgical needle. After subjecting both the non-latex and latex double-glove hole puncture indication systems to surgical needle puncture in each glove fingertip, these double-glove systems were immersed in a sterile basin of saline, after which the double-gloved hands manipulated surgical instruments. Within two minutes, both the non-latex and latex hole puncture indication systems accurately detected needle punctures in all of the surgical gloves, regardless of the dimensions of the surgical needles. In addition, the size of the color change visualized through the translucent outer glove did not correlate with needle diameter. On the basis of this extensive experimental evaluation, both the non-latex and latex double-glove hole puncture indication systems should be used in all operative procedures by all operating room personnel.
Dong, Ren G.; Welcome, Daniel E.; Peterson, Donald R.; Xu, Xueyan S.; McDowell, Thomas W.; Warren, Christopher; Asaki, Takafumi; Kudernatsch, Simon; Brammer, Antony
2015-01-01
Vibration-reducing (VR) gloves have been increasingly used to help reduce vibration exposure, but it remains unclear how effective these gloves are. The purpose of this study was to estimate tool-specific performances of VR gloves for reducing the vibrations transmitted to the palm of the hand in three orthogonal directions (3-D) in an attempt to assess glove effectiveness and aid in the appropriate selection of these gloves. Four typical VR gloves were considered in this study, two of which can be classified as anti-vibration (AV) gloves according to the current AV glove test standard. The average transmissibility spectrum of each glove in each direction was synthesized based on spectra measured in this study and other spectra collected from reported studies. More than seventy vibration spectra of various tools or machines were considered in the estimations, which were also measured in this study or collected from reported studies. The glove performance assessments were based on the percent reduction of frequency-weighted acceleration as is required in the current standard for assessing the risk of vibration exposures. The estimated tool-specific vibration reductions of the gloves indicate that the VR gloves could slightly reduce (<5%) or marginally amplify (<10%) the vibrations generated from low-frequency (<25 Hz) tools or those vibrating primarily along the axis of the tool handle. With other tools, the VR gloves could reduce palm-transmitted vibrations in the range of 5%–58%, primarily depending on the specific tool and its vibration spectra in the three directions. The two AV gloves were not more effective than the other gloves with some of the tools considered in this study. The implications of the results are discussed. Relevance to industry Hand-transmitted vibration exposure may cause hand-arm vibration syndrome. Vibration-reducing gloves are considered as an alternative approach to reduce the vibration exposure. This study provides useful information on the effectiveness of the gloves when used with many tools for reducing the vibration transmitted to the palm in three directions. The results can aid in the appropriate selection and use of these gloves. PMID:26726275
Evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration.
Griffin, M J
1998-05-01
A method of evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration is proposed. The glove isolation effectiveness was calculated from: (a) the measured transmissibility of a glove, (b) the vibration spectrum on the handle of a specific tool (or class of tools), and (c) the frequency weighting indicating the degree to which different frequencies of vibration cause injury. With previously reported tool vibration spectra and glove transmissibilities (from 10-1000 Hz), the method was used to test 10 gloves with 20 different powered tools. The frequency weighting for hand-transmitted vibration advocated in British standard 6842 (1987) and international standard 5349 (1986) greatly influences the apparent isolation effectiveness of gloves. With the frequency weighting, the gloves had little effect on the transmission of vibration to the hand from most of the tools. Only for two or three tools (those dominated by high frequency vibration) did any glove provide useful attenuation. Without the frequency weighting, some gloves showed useful attenuation of the vibration on most powered tools. In view of the uncertain effect of the vibration frequency in the causation of disorders from hand-transmitted vibration, it is provisionally suggested that the wearing of a glove by the user of a particular vibratory tool could be encouraged if the glove reduces the transmission of vibration when it is evaluated without the frequency weighting and does not increase the vibration when it is evaluated with the frequency weighting. A current international standard for the measurement and evaluation of the vibration transmitted by gloves can classify a glove as an antivibration glove when it provides no useful attenuation of vibration, whereas a glove providing useful attenuation of vibration on a specific tool can fail the test.
Lefebvre, Daniel R; Strande, Louise F; Hewitt, Charles W
2008-01-01
Acquiring a blood-borne disease is a risk of performing operations. Most data about seroconversion are based on hollow-bore needlesticks. Some studies have examined the inoculation volumes of pure blood delivered by suture needles. There is a lack of data about the effect of double-gloving on contaminant transmission in less viscous fluids that are not prone to coagulation. We used enzymatic colorimetry to quantify the volume of inoculation delivered by a suture needle that was coated with an aqueous contaminant. Substrate color change was measured using a microplate reader. Both cutting and tapered suture needles were tested against five different glove types and differing numbers of glove layers (from zero to three). One glove layer removed 97% of contaminant from tapered needles and 65% from cutting needles, compared with the no-glove control data. Additional glove layers did not significantly improve contaminant removal from tapered needles (p > 0.05). For the cutting needle, 2 glove layers removed 91% of contaminant, which was significantly better than a single glove (p = 0.002). Three glove layers did not afford statistically significant additional protection (p = 0.122). There were no statistically significant differences between glove types (p = 0.41). With an aqueous needle contaminant, a single glove layer removes contaminant from tapered needles as effectively as multiple glove layers. For cutting needles, double-glove layering offers superior protection. There is no advantage to triple-glove layering. A surgeon should double-glove for maximum safety. Additionally, a surgeon should take advantage of other risk-reduction strategies, such as sharps safety, risk management, and use of sharpless instrumentation when possible.
Use of Traditional and Novel Methods to Evaluate the Influence of an EVA Glove on Hand Performance
NASA Technical Reports Server (NTRS)
Benson, Elizabeth A.; England, Scott A.; Mesloh, Miranda; Thompson, Shelby; ajulu, Sudhakar
2010-01-01
The gloved hand is one of an astronaut s primary means of interacting with the environment, and any restrictions imposed by the glove can strongly affect performance during extravehicular activity (EVA). Glove restrictions have been the subject of study for decades, yet previous studies have generally been unsuccessful in quantifying glove mobility and tactility. Past studies have tended to focus on the dexterity, strength, and functional performance of the gloved hand; this provides only a circumspect analysis of the impact of each type of restriction on the glove s overall capability. The aim of this study was to develop novel capabilities to provide metrics for mobility and tactility that can be used to assess the performance of a glove in a way that could enable designers and engineers to improve their current designs. A series of evaluations were performed to compare unpressurized and pressurized (4.3 psi) gloved conditions with the ungloved condition. A second series of evaluations were performed with the Thermal Micrometeoroid Garment (TMG) removed. This series of tests provided interesting insight into how much of an effect the TMG has on gloved mobility - in some cases, the presence of the TMG restricted glove mobility as much as pressurization did. Previous hypotheses had assumed that the TMG would have a much lower impact on mobility, but these results suggest that an improvement in the design of the TMG could have a significant impact on glove performance. Tactility testing illustrated the effect of glove pressurization, provided insight into the design of hardware that interfaces with the glove, and highlighted areas of concern. The metrics developed in this study served to benchmark the Phase VI EVA glove and to develop requirements for the next-generation glove for the Constellation program.
Zaatreh, Sarah; Enz, Andreas; Klinder, Annett; König, Tony; Mittelmeier, Lena; Kundt, Günther; Mittelmeier, Wolfram
2016-01-01
Introduction: Surgical gloves are used to prevent contamination of the patient and the hospital staff with pathogens. The aim of this study was to examine the actual effectiveness of gloves by examining the damage (perforations, tears) to latex gloves during surgery in the case of primary hip and knee prosthesis implantation. Materials and methods: Latex surgical gloves used by surgeons for primary hip and knee replacement surgeries were collected directly after the surgery and tested using the watertightness test according to ISO EN 455-1:2000. Results: 540 gloves were collected from 104 surgeries. In 32.7% of surgeries at least one glove was damaged. Of all the gloves collected, 10.9% were damaged, mainly on the index finger. The size of the perforations ranged from ≤1 mm to over 5 mm. The surgeon's glove size was the only factor that significantly influenced the occurrence of glove damage. Surgeon training level, procedure duration, and the use of bone cement had no significant influence. Conclusions: Our results highlight the high failure rate of surgical gloves. This has acute implications for glove production, surgical practice, and hygiene guidelines. Further studies are needed to detect the surgical steps, surface structures, and instruments that pose an increased risk for glove damage.
Gloves Reprocessing: Does It Really Save Money?
Arora, Pankaj; Kumari, Santosh; Sodhi, Jitender; Talati, Shweta; Gupta, Anil Kumar
2015-12-01
Gloves are reprocessed and reused in health-care facilities in resource-limited settings to reduce the cost of availability of gloves. The study was done with the aim to compute the cost of reprocessing of gloves so that an economically rationale decision can be taken. A retrospective record-based cross-sectional study was undertaken in a central sterile supply department where different steps during reprocessing of gloves were identified and the cost involved in reprocessing per pair of gloves was calculated. The cost of material and manpower was calculated to arrive at the cost of reprocessing per pair of gloves. The cost of a reprocessed pair of surgical gloves was calculated to be Indian Rupee (INR) 14.33 which was greater than the cost of a new pair of disposable surgical gloves (INR 9.90) as the cost of sterilization of one pair of gloves itself came out to be INR 10.97. The current study showed that the purchase of sterile disposable single-use gloves is cheaper than the process of recycling. Reprocessing of gloves is not economical on tangible terms even in resource-limited settings, and from the perspective of better infection control as well as health-care worker safety, it further justifies the use of disposable gloves.
Risk of exposure to potential vector mosquitoes for rural workers in Northern Lao PDR
Thammavong, Phoutmany; Lindsay, Steve W.; Brey, Paul T.
2017-01-01
Background One major consequence of economic development in South-East Asia has been a rapid expansion of rubber plantations, in which outbreaks of dengue and malaria have occurred. Here we explored the difference in risk of exposure to potential dengue, Japanese encephalitis (JE), and malaria vectors between rubber workers and those engaged in traditional forest activities in northern Laos PDR. Methodology/Principal findings Adult mosquitoes were collected for nine months in secondary forests, mature and immature rubber plantations, and villages. Human behavior data were collected using rapid participatory rural appraisals and surveys. Exposure risk was assessed by combining vector and human behavior and calculating the basic reproduction number (R0) in different typologies. Compared to those that stayed in the village, the risk of dengue vector exposure was higher for those that visited the secondary forests during the day (odds ratio (OR) 36.0), for those living and working in rubber plantations (OR 16.2) and for those that tapped rubber (OR 3.2). Exposure to JE vectors was also higher in the forest (OR 1.4) and, similar when working (OR 1.0) and living in the plantations (OR 0.8). Exposure to malaria vectors was greater in the forest (OR 1.3), similar when working in the plantations (OR 0.9) and lower when living in the plantations (OR 0.6). R0 for dengue was >2.8 for all habitats surveyed, except villages where R0≤0.06. The main malaria vector in all habitats was Anopheles maculatus s.l. in the rainy season and An. minimus s.l. in the dry season. Conclusions/Significance The highest risk of exposure to vector mosquitoes occurred when people visit natural forests. However, since rubber workers spend long periods in the rubber plantations, their risk of exposure is increased greatly compared to those who temporarily enter natural forests or remain in the village. This study highlights the necessity of broadening mosquito control to include rubber plantations. PMID:28742854
Hiessl, Sebastian; Schuldes, Jörg; Thürmer, Andrea; Halbsguth, Tobias; Bröker, Daniel; Angelov, Angel; Liebl, Wolfgang; Daniel, Rolf
2012-01-01
The increasing production of synthetic and natural poly(cis-1,4-isoprene) rubber leads to huge challenges in waste management. Only a few bacteria are known to degrade rubber, and little is known about the mechanism of microbial rubber degradation. The genome of Gordonia polyisoprenivorans strain VH2, which is one of the most effective rubber-degrading bacteria, was sequenced and annotated to elucidate the degradation pathway and other features of this actinomycete. The genome consists of a circular chromosome of 5,669,805 bp and a circular plasmid of 174,494 bp with average GC contents of 67.0% and 65.7%, respectively. It contains 5,110 putative protein-coding sequences, including many candidate genes responsible for rubber degradation and other biotechnically relevant pathways. Furthermore, we detected two homologues of a latex-clearing protein, which is supposed to be a key enzyme in rubber degradation. The deletion of these two genes for the first time revealed clear evidence that latex-clearing protein is essential for the microbial utilization of rubber. Based on the genome sequence, we predict a pathway for the microbial degradation of rubber which is supported by previous and current data on transposon mutagenesis, deletion mutants, applied comparative genomics, and literature search. PMID:22327575
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemonds, David Preston
A breech lock for a glove box is provided that may be used to transfer one or more items into the glove box. The breech lock can be interchangeably installed in place of a plug, glove, or other device in a port or opening of a glove box. Features are provided to aid the removal of items from the breech lock by a gloved operator. The breech lock can be reused or, if needed, can be replaced with a plug, glove, or other device at the port or opening of the glove box.
The effect of surface and season on playground injury rates
Branson, Lara Joan; Latter, John; Currie, Gillian R; Nettel-Aguirre, Alberto; Embree, Tania; Hagel, Brent Edward
2012-01-01
OBJECTIVE: To examine the effect of season on playground surface injury rates. METHODS: Injuries were identified through student incident report forms used in school districts in Calgary (Alberta) and the surrounding area. Playground surface exposure data were estimated based on school enrollment. RESULTS: A total of 539 injuries were reported during the 2007/2008 school year. Abrasions, bruises and inflammation were the most frequently reported injuries. The head, neck or face were most commonly injured. Injury rates per 1000 student days ranged between 0.018 (rubber crumb in spring) and 0.08 (poured-in-place and natural rock in the fall). Rubber crumb surfacing, compared with natural rock, had a significantly lower rate of injury in the spring, but no other season-surface comparisons were statistically significant. CONCLUSIONS: Rates of injury were similar for natural rock, poured-in-place, and crushed rock in the fall and winter. There was some evidence of a lower rate of injury on rubber crumb surfaces in the spring. PMID:24179416
Tadakaluru, Sreenivasulu; Thongsuwan, Wiradej; Singjai, Pisith
2014-01-06
Conventional metallic strain sensors are flexible, but they can sustain maximum strains of only ~5%, so there is a need for sensors that can bear high strains for multifunctional applications. In this study, we report stretchable and flexible high-strain sensors that consist of entangled and randomly distributed multiwall carbon nanotubes or graphite flakes on a natural rubber substrate. Carbon nanotubes/graphite flakes were sandwiched in natural rubber to produce these high-strain sensors. Using field emission scanning electron microscopy, the morphology of the films for both the carbon nanotube and graphite sensors were assessed under different strain conditions (0% and 400% strain). As the strain was increased, the films fractured, resulting in an increase in the electrical resistance of the sensor; this change was reversible. Strains of up to 246% (graphite sensor) and 620% (carbon nanotube sensor) were measured; these values are respectively ~50 and ~120 times greater than those of conventional metallic strain sensors.
Tadakaluru, Sreenivasulu; Thongsuwan, Wiradej; Singjai, Pisith
2014-01-01
Conventional metallic strain sensors are flexible, but they can sustain maximum strains of only ∼5%, so there is a need for sensors that can bear high strains for multifunctional applications. In this study, we report stretchable and flexible high-strain sensors that consist of entangled and randomly distributed multiwall carbon nanotubes or graphite flakes on a natural rubber substrate. Carbon nanotubes/graphite flakes were sandwiched in natural rubber to produce these high-strain sensors. Using field emission scanning electron microscopy, the morphology of the films for both the carbon nanotube and graphite sensors were assessed under different strain conditions (0% and 400% strain). As the strain was increased, the films fractured, resulting in an increase in the electrical resistance of the sensor; this change was reversible. Strains of up to 246% (graphite sensor) and 620% (carbon nanotube sensor) were measured; these values are respectively ∼50 and ∼120 times greater than those of conventional metallic strain sensors. PMID:24399158
DEVELOPMENT OF A NEW GLOVE FOR GLOVE BOXES WITH HIGH-LEVEL PERFORMANCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blancher, J.; Poirier, J.M.
2003-02-27
This paper describes the results of a joint technological program of COGEMA and MAPA to develop a new generation of glove for glove boxes. The mechanical strength of this glove is twice as high as the best characteristics of gloves available on the market. This new generation of product has both a higher level of performance and better ergonomics.
NASA Astrophysics Data System (ADS)
Chen, Y.; Guan, J.; Hu, H.; Gao, H.; Zhang, L.
2016-07-01
A series of natural rubber/styrene butadiene rubber/polybutadiene rubber composites was prepared with nanometer silica and micron kaolin by a dry modification process, mechanical compounding, and mold vulcanization. Fourier transform infrared spectroscopy and a scanning electron microscope were used to investigate the structural changes and interfacial interactions in composites. The results showed that the "seesaw" structure was formed particularly with the incorporation of silica particles in the preparation process, which would be beneficial to the dispersibility of fillers in the rubber matrix. The kaolinite platelets were generally arranged in directional alignment. Kaolinite with smaller particle size and low-defect structure was more stable in preparation, but kaolinite with larger particle size and high defect structure tended to change the crystal structure. The composite prepared in this research exhibited excellent mechanical and thermal properties.
Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration
Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.
2016-01-01
BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for better effectiveness for protecting the fingers. PMID:27867313
Glove perforations during open surgery for gynaecological malignancies.
Manjunath, A P; Shepherd, J H; Barton, D P J; Bridges, J E; Ind, T E J
2008-07-01
To audit glove perforations at laparotomies for gynaecological cancers. Gynaecological oncology unit, cancer centre, London. Prospective audit. Twenty-nine laparotomies for gynaecological cancers over 3 months. Gloves used during laparotomies for gynaecological cancer were tested for perforations by the air inflation and water immersion technique. Parameters recorded were: type of procedure, localisation of perforation, type of gloves, seniority of surgeon, operation time and awareness of perforations. Glove perforation rate. Perforations were found in gloves from 27/29 (93%) laparotomies. The perforation rate was 61/462 (13%) per glove. The perforation rate was three times higher when the duration of surgery was more than 5 hours. The perforation rate was 63% for primary surgeons, 54.5% for first assistant, 4.7% for second assistant and 40.5% for scrub nurses. Clinical fellows were at highest risk of injury (94%). Two-thirds of perforations were on the index finger or thumb. The glove on the nondominant hand had perforations in 54% of cases. In 50% of cases, the participants were not aware of the perforations. There were less inner glove perforations in double gloves compared with single gloves (5/139 versus 26/154; P = 0.0004, OR = 5.4, 95% CI 1.9-16.7). The indicator glove system failed to identify holes in 44% of cases. Glove perforations were found in most (93%) laparotomies for gynaecological malignancies. They are most common among clinical fellows, are often unnoticed and often not detected by the indicator glove system.
Novais, Samuel M A; Macedo-Reis, Luiz E; DaRocha, Wesley D; Neves, Frederico S
2016-06-01
Human pressure on natural habitats increases the importance of agroforests for biodiversity conservation. The objective of this study was to evaluate the role of cacao traditional cultivation system (CTCS) on the conservation of the herbivorous insect community when compared with a monodominant rubber agroforest, a type of agricultural system for cacao cultivation. The insects were sampled in three habitats in Southeastern Bahia, Brazil: native forests, CTCS and rubber agroforests. In each habitat, 18 plots of 10 m2 were established, and the structural measures were collected and herbivorous insects were sampled with a Malaise/window trap. The diversity of folivorous decreased with the simplification of vegetation structure, but species composition was similar among habitats. In addition to a decrease in the availability of resources in monodominant rubber agroforests, the latex present in these systems have limited the occurrence of species that cannot circumvent latex toxicity. The diversity of sap-sucking insects was similar among habitats, but species composition was similar only in the CTCS and native forest, and it was different in the rubber agroforest. We observed turnover and a higher frequency of individuals of the family Psyllidae in the rubber agroforest. The biology and behavior of Psyllids and absence of natural enemies enable their diversity to increase when they are adapted to a new host. We observed a shift in the composition of xylophagous insects in the rubber agroforest compared to that in other habitats. Moreover, this agroforest has low species richness, but high individual abundance. Latex extraction is likely an important additional source of volatile compounds discharged into the environment, and it increases the attraction and recruitment of coleoborers to these sites. We concluded that CTCS has an herbivorous insect community with a structure similar to the community found in native forests of the region, and they present a more interesting conservation strategy when compared to rubber agroforests. We also emphasized the potential risk of local pest outbreaks in rubber agroforests for both the rubber and associated cacao trees.
Influence of wearing latex gloves on electric pulp tester readings in children.
Holan, G
1993-12-01
Electric pulp testers operated by completing an electric circuit. Latex examination gloves have been claimed to interrupt this circuit and lead to false-negative results. This study was conducted to evaluate the influence of wearing latex gloves on electric pulp tester (EPT) readings. The pulps of 80 maxillary permanent incisors of 22 children 10-13 1/2 years old were tested using the Pelton & Crane 'Vitapulp' instrument. Each tooth was tested twice: with gloves and with bare hands. Teeth failing to respond to the EPT without gloves were excluded from the study. All EPT readings ranged between 1 and 9.5. Five teeth gave the same responses with gloved and ungloved hands. Only five teeth did not respond when gloves were worn, and all of these gave readings near the top of the EPT scale when tested without gloves. The other 70 teeth presented significantly higher readings with gloves than without gloves. It is concluded that removal of examination gloves during the operation of the EPT is necessary only if no response is obtained.
Methods for reducing energy dissipation in cosmetic gloves.
Herder, J L; Cool, J C; Plettenburg, D H
1998-06-01
For cosmetic reasons, hand prostheses are provided with cosmetic gloves. Their pleasing appearance, however, is accompanied by poor mechanical behavior, resulting in a negative influence on prosthesis operation. Glove stiffness is high and nonlinear, and internal friction in the glove material causes energy dissipation (hysteresis). In this article, two methods for reducing hysteresis in cosmetic gloves are proposed, that may be applied independently or in combination. Glove modification. Altering the mechanical properties of the glove itself is the first method that is presented. It was found possible to reduce both stiffness and hysteresis about 50% by forming grooves into the inside of the glove. Together with the evaluation of this method, several properties of the cosmetic glove were determined. Motion optimization. Additionally, a second method for reducing hysteresis was developed. The amount of hysteresis is influenced by the way the glove is forced to deform. The prosthesis mechanism, determining this deformation, was designed for minimum hysteresis and maximum cosmesis. For the prosthesis-glove combination used in this study, thumb motion optimization reduced hysteresis by about 65%.
The effects of vibration-reducing gloves on finger vibration
Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.
2015-01-01
Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new results and knowledge can be used to help select appropriate gloves for the operations of powered hand tools, to help perform risk assessment of the vibration exposure, and to help design better VR gloves. PMID:26543297
[Destruction of the solid-cast rubber tyres by microscopic fungi].
Chuienko, A I; Subbota, A H; Zhdanova, N M
2010-01-01
Resistance to the action of standard test-cultures of fungi (in accordance with GOST 9.049-91 of the former U.S.S.R.) and species, isolated from rubber substrates of two types of the poured rubber tyres, which contained natural and synthetic plasticizer, have been investigated. It has been shown that the strains, isolated from rubber materials have an ability to deteriorate rubber tyres of two types, in contrast to standard species, which caused deterioration only to the tyres, containing the synthetic plasticizer. It has been described in our investigations that fungal resistance of studied tyres decrease with time (on the 28th and 365th day, accordingly), that is shown in full overgrowing of tyre samples, in destruction of their surfaces and in changing of their hardness. Such changes are accompanied by processes of oxidation of rubber, degradation of plasticizer, and by deleaching of such inorganic components of rubber as calcium carbonate, kaolin and zeolite. This information is presented on IR-spectrograms of investigated samples as the absence or presence of absorption frequencies of different intensity that corresponded to aromatic, hydroxyl, ester, alcohol, nitrile and inorganic groups. The paper is presented in Ukrainian.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toki,S.; Minouchi, N.; Sics, I.
2008-01-01
The tensile strength of rubber depends on a combination of contributions, in particular on the finite extensibility of chain segments between network points and on strain-induced crystallization. In order to achieve high tensile strength at high strain at break, we optimized the composition and processing parameters to gain high molecular flexibility by the cure conditions, to acquire high flexibility of sulfur bridges by the accelerator, and to increase the modulus level without losing rubber molecule flexibility by carbon black. As a result, our formula performed a tensile strength of 42.5 MPa at 25 C under ISO-37, as officially measured bymore » the Society of Rubber Industry, Japan, in 2004.« less
Comparison of nitrile gloves and nitrile over Nomex gloves.
Vorih, Deirdre Cronin; Bolton, Lauri D; Marcelynas, James; Nowicki, Thomas A; Jacobs, Lenworth; Robinson, Kenneth J
2009-01-01
Aeromedical flight crews must perform many tasks in flight requiring manual dexterity and fine precision. A common perception is that safety-enhancing fire-retardant gloves compromise patient care if worn during such tasks by providing added bulk and barrier to the hand. This study is a quantitative and qualitative analysis of this possible compromise to patient care. Sixteen practicing flight nurses and respiratory therapists were asked to perform 10 different standard patient care tasks while wearing either nitrile gloves or a nitrile-Nomex glove pair. Tasks were timed, rated as completed successfully or not, and were subsequently judged subjectively by the participants. Whereas the time required to insert an intravenous catheter and to insert a central line while wearing only nitrile gloves was significantly faster than when wearing both gloves, the time to perform all other tasks was not significantly different. In subjective ratings, the nitrile glove alone was scored significantly better than the two-glove combination by the study participants. Comfort, dexterity, tactile discrimination, and ease of use were all adversely affected by wearing a Nomex glove under a nitrile glove. Although the differences in times for most tasks may not be clinically significant, the difference in the subjective parameters may be great enough to cause helicopter emergency medical services (HEMS) practitioners to not wear Nomex gloves under nitrile gloves while performing procedures.
Rubber dam isolation--key to success in diastema closure technique with direct composite resin.
Barros de Campos, Paulo Ricardo; Maia, Rodrigo Rocha; Rodrigues de Menezes, Livia; Barbosa, Isabel Ferreira; Carneiro da Cunha, Amanda; da Silveira Pereira, Gisele Damiana
2015-01-01
The use of direct composite resin for diastema closure has technique advantages, including that the restorative procedure can be carried out in one appointment at a reasonable cost and without the removal of sound tooth structure. The use of a rubber dam for closing diastemas with composite resin is of paramount importance as it prevents moisture contamination and ensures increased gingival retraction compared to other techniques. This provides better access to the cervical area of the tooth, facilitating proper placement of resin to recreate the natural anatomical contours and contact point. Thus, there is a more natural adaptation of the restoration to the gingival tissue, avoiding a space between the papilla and the restored tooth. To illustrate the advantages of this technique, two diastema closure cases are presented using direct composite resin with rubber dam isolation.
Power assist EVA glove development
NASA Technical Reports Server (NTRS)
Main, John A.; Peterson, Steven W.; Strauss, Alvin M.
1992-01-01
Structural modeling of the EVA glove indicates that flexibility in the metacarpophalangeal (MCP) joint can be improved by selectively lowering the elasticity of the glove fabric. Two strategies are used to accomplish this. One method uses coil springs on the back of the glove to carry the tension in the glove skin due to pressurization. These springs carry the loads normally borne by the glove fabric, but are more easily deformed. An active system was also designed for the same purpose and uses gas filled bladders attached to the back of the EVA glove that change the dimensions of the back of the glove and allow the glove to bend at the MCP joint, thus providing greater flexibility at this joint. A threshold control scheme was devised to control the action of the joint actuators. Input to the controller was provided by thin resistive pressure sensors placed between the hand and the pressurized glove. The pressure sensors consist of a layer of polyester film that has a thin layer of ink screened on the surface. The resistivity of the ink is pressure dependent, so an extremely thin pressure sensor can be fabricated by covering the ink patch with another layer of polyester film and measuring the changing resistance of the ink with a bridge circuit. In order to sense the force between the hand and the glove at the MCP joint, a sensor was placed on the palmar face of the middle finger. The resultant signal was used by the controller to decide whether to fill or exhaust the bladder actuators on the back of the glove. The information from the sensor can also be used to evaluate the effectiveness of a given control scheme or glove design since the magnitude of the measured pressures gives some idea of the torque required to bend a glove finger at the MCP joint. Tests of this actuator, sensor, and control system were conducted in an 57.2 kPa glove box by performing a series of 90 degree finger bends with a glove without an MCP joint assembly, a glove with the coil spring assembly, and with the four fingered actuated glove. The tests of these three glove designs confirm the validity of the model.
NASA Technical Reports Server (NTRS)
Rajulu, Sudhakar; Benson, Elizabeth; England, Scott; Mesloh, Miranda; Thompson, Shelby
2009-01-01
The gloved hand is an astronaut s primary means of interacting with the environment, so performance on an EVA is strongly impacted by any restrictions imposed by the glove. As a result, these restrictions have been the subject of study for decades. However, previous studies have generally been unsuccessful in quantifying glove mobility and tactility. Instead, studies have tended to focus on the dexterity, strength and functional performance of the gloved hand. Therefore, it has been difficult to judge the impact of each type of restriction on the glove s overall capability. The lack of basic information on glove mobility in particular, is related to the difficulty in instrumenting a gloved hand to allow an accurate evaluation. However, the current study aims at developing novel technological capabilities to provide metrics for mobility and tactility that can be used to assess the performance of a glove in a way that could enable designers and engineers to improve upon their current designs. A series of evaluations were performed in ungloved, unpressurized and pressurized (4.3 psi) conditions, to allow a comparison across pressures and to the baseline barehanded condition. In addition, a subset of the testing was also performed with the Thermal Micrometeoroid Garment (TMG) removed. This test case in particular provided some interesting insight into how much of an impact the TMG has on gloved mobility -- in some cases, as much as pressurization of the glove. Previous rule-of-thumb estimates had assumed that the TMG would have a much lower impact on mobility, while these results suggest that an improvement in the TMG could actually have a significant impact on glove performance. Similarly, tactility testing illustrated the impact of glove pressurization on tactility and provided insight on the design of interfaces to the glove. The metrics described in this paper have been used to benchmark the Phase VI EVA glove and to develop requirements for the next generation glove for the Constellation program.
Erickson, Marilyn C; Liao, Jye-Yin; Webb, Cathy C; Habteselassie, Mussie Y; Cannon, Jennifer L
2018-02-02
Gloves are worn by workers harvesting ready-to-eat produce as a deterrent for contaminating the produce with enteric pathogens that may reside on their hands. As fields are not sterile environments, the probability for gloves to become contaminated still exists and therefore it is critical to understand the conditions that affect the survival of pathogens on gloves. Both Escherichia coli O157:H7 and Salmonella deposited on glove surfaces in a liquid state survived longer when the pathogen had been suspended in lettuce sap than when suspended in water. Despite this protection, pathogens deposited on clean single-use gloves were more likely to survive during drying than pathogens deposited on dirty gloves (a film of lettuce sap had been applied to the surface prior to pathogen application and soil had been ground into the gloves). Survival of both E. coli O157:H7 and Salmonella was biphasic with the greatest losses occurring during the first hour of drying followed by much slower losses in the ensuing hours. Pathogens grown in rich media (tryptic soy broth) versus minimal media (M9) as well as those cultured on solid agar versus liquid broth were also more likely to be resistant to desiccation when deposited onto gloves. Although survival of E. coli O157:H7 on nitrile gloves was in general greater than it was on latex gloves, the relative survival of Salmonella on the two glove types was inconsistent. Due to these inconsistencies, no one glove type is considered better than another in reducing the risk for contamination with enteric pathogens. In addition, the extended survival of what are generally referred to as stress-resistant pathogens suggests that gloves either be changed frequently during the day or washed in a disinfectant to reduce the risk of glove contamination that could otherwise contaminate product handled with the contaminated gloves. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Heping; Fan, Yujie; Yang, Jianghua; Qi, Jiyan; Li, Huibo
2013-01-01
Increasing demand for natural rubber prompts studies into the mechanisms governing the productivity of rubber tree ( Hevea brasiliensis ). It is very interesting to notice that a rubber tree of clone PR107 in Yunnan, China is reported to yield more than 20 times higher than the average rubber tree. This super-high-yielding (SHY) rubber tree (designated as SY107), produced 4.12 kg of latex (cytoplasm of rubber producing laticifers, containing about 30% of rubber) per tapping, more than 7-fold higher than that of the control. This rubber tree is therefore a good material to study how the rubber production is regulated at a molecular aspect. A comprehensive cDNA-AFLP transcript profiling was performed on the latex of SY107 and its average counterparts by using the 384 selective primer pairs for two restriction enzyme combinations (ApoI/MseI and TaqI/MseI). A total of 746 differentially expressed (DE) transcript-derived fragments (TDFs) were identified, of which the expression patterns of 453 TDFs were further confirmed by RT-PCR. These RT-PCR confirmed TDFs represented 352 non-redundant genes, of which 215 had known or partially known functions and were grouped into 10 functional categories. The top three largest categories were transcription and protein synthesis (representing 24.7% of the total genes), defense and stress (15.3%), and primary and secondary metabolism (14.0%). Detailed analysis of the DE-genes suggests notable characteristics of SHY phenotype in improved sucrose loading capability, rubber biosynthesis-preferred sugar utilization, enhanced general metabolism and timely stress alleviation. However, the SHY phenotype has little correlation with rubber-biosynthesis pathway genes. PMID:24066172
Stelescu, Maria-Daniela; Manaila, Elena; Craciun, Gabriela; Chirila, Corina
2017-07-11
Natural rubber composites filled with short natural fibers (flax and sawdust) were prepared by blending procedure and the elastomer cross-linking was carried out using benzoyl peroxide. The microbial degradation of composites was carried out by incubating with Aspergillus niger recognized for the ability to grow and degrade a broad range of substrates. The extent of biodegradation was evaluated by weight loss and cross-linking degree study of composites after 2 months incubation in pure shake culture conditions. Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR) have proved to be precious and valuable instruments for morphological as well as structural characterization of the composites before and after incubation with Aspergillus niger .
Stelescu, Maria-Daniela; Manaila, Elena; Craciun, Gabriela; Chirila, Corina
2017-01-01
Natural rubber composites filled with short natural fibers (flax and sawdust) were prepared by blending procedure and the elastomer cross-linking was carried out using benzoyl peroxide. The microbial degradation of composites was carried out by incubating with Aspergillus niger recognized for the ability to grow and degrade a broad range of substrates. The extent of biodegradation was evaluated by weight loss and cross-linking degree study of composites after 2 months incubation in pure shake culture conditions. Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR) have proved to be precious and valuable instruments for morphological as well as structural characterization of the composites before and after incubation with Aspergillus niger. PMID:28773145
Experimental study on the drying of natural latex medical gloves
NASA Astrophysics Data System (ADS)
Chankrachang, Mano; Yongyingsakthavorn, Pisit; Tohsan, Atitaya; Nontakaew, Udomkiat
2018-01-01
The purpose of this research was to study latex film drying at 70 °C using a laboratory drying oven. Two different total solid content (TSC) latex compounds, which 45% TSC and 35% TSC were used. The undried latex films were prepared according to the common procedures used in latex gloves manufacturers, that is, by dry coagulant dipping process. The experimental results such as initial moisture content, the amount of moisture and drying time of latex films in each latex compound formula were determined. After that, the results were projected to calculate on the production capacity expand by 1 million piece/day of natural latex medical gloves. Finally, the rate of moisture entering the latex drying oven and the energy consumption of the drying oven were estimated. The results indicated that when the 35% TSC of latex compound was used. The initial moisture content of latex film was higher than 45% TSC of latex compound about 7%. The drying time of 35% TSC was longer than 45% TSC for 2.5 min and consume more energy about 10%. As a result, the 45% TSC latex compound was the better way to saving energy and managing humidity in the production line. Therefore, it was found to very useful to an approximate design length and size of actual of latex drying oven and the rate of moisture entering the oven as well.
2014-01-01
Background The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. Results We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. Conclusions The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility. PMID:24512148
Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.
McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher
2013-01-01
Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.
Rock, Clare; Harris, Anthony D; Reich, Nicholas G; Johnson, J Kristie; Thom, Kerri A
2013-11-01
Hand hygiene (HH) is recognized as a basic effective measure in prevention of nosocomial infections. However, the importance of HH before donning nonsterile gloves is unknown, and few published studies address this issue. Despite the lack of evidence, the World Health Organization and other leading bodies recommend this practice. The aim of this study was to assess the utility of HH before donning nonsterile gloves prior to patient contact. A prospective, randomized, controlled trial of health care workers entering Contact Isolation rooms in intensive care units was performed. Baseline finger and palm prints were made from dominant hands onto agar plates. Health care workers were then randomized to directly don nonsterile gloves or perform HH and then don nonsterile gloves. Postgloving finger and palm prints were then made from the gloved hands. Plates were incubated and colony-forming units (CFU) of bacteria were counted. Total bacterial colony counts of gloved hands did not differ between the 2 groups (6.9 vs 8.1 CFU, respectively, P = .52). Staphylococcus aureus was identified from gloves (once in "hand hygiene prior to gloving" group, twice in "direct gloving" group). All other organisms were expected commensal flora. HH before donning nonsterile gloves does not decrease already low bacterial counts on gloves. The utility of HH before donning nonsterile gloves may be unnecessary. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Malhotra, Monika; Sharma, Jai Bhagwan; Wadhwa, Leena; Arora, Raksha
2004-08-01
To assess the glove perforation rate, efficacy of double gloving, effect of duration of surgery, expertise of surgeon and operative urgency on the glove perforation rate in obstetrical and gynecologic operations. From February to September 2002, double glove protocol was made necessary for all major obstetrical and gynecologic procedures. The operating surgeon, first and second assistant were included in the study. Gloves damage was noted (overt by inspection, occult by hydroinsufflation technique). Of the 156 procedures included in study, 32 procedures were performed (all emergency operations) single-gloved because surgeons found double gloving clumsy (56%), made it difficult to tie knots due to lack of dexterity (24%), or were too tight (20%). One thousand one hundred and twenty single gloves were examined after each procedure by hydroinsufflation. The overall perforation rate was 13.6% (single versus double outer gloves, 13.8% versus l3.2%, P > 0.05). Matching perforations were found in six cases (4.6%). Thus, the protection offered by double gloves was 95.4% even if the outer gloves were perforated. Four inner gloves had preexisting perforations. Sixty unused gloves checked similarly revealed a perforation rate of 1.6%. Emergency cases had higher perforation rate compared to elective surgeries (16.6% versus 10.8%, P < 0.00 1). Surgeries lasting for more than 40 min had a higher perforation rate compared to those finished in less than or equal to 40 min (18.6% versus 7.6%, P < 0.001). The middle finger of the left hand was the most commonly involved. The surgeon, first assistant and second assistant were involved in 73.6, 23.3 and 3.2% cases, respectively. Double gloving offers considerable protection against exposure to contaminants in the blood and body fluids of the patient and should be made routine, especially in developing countries where HIV, hepatitis B and C are widely prevalent. Double gloving should be made mandatory in emergency procedures, which have a higher perforation rate due to operative urgency, and gloves should be changed in operations lasting for more than 40 min to ensure integrity of barrier.
Comparison of 4 different types of surgical gloves used for preventing blood contact.
Wittmann, Andreas; Kralj, Nenad; Köver, Jan; Gasthaus, Klaus; Lerch, Hartmut; Hofmann, Friedrich
2010-05-01
Needlestick injuries are always associated with a risk of infection, because these types of punctures may expose healthcare workers to a patient's blood and/or body fluids. To compare the efficacy of 4 different types of surgical gloves for preventing exposure to blood as a result of needlestick injury. For simulation of needlestick injury, a circular sample of pork skin was tightened onto a bracket, and a single finger from a medical glove was stretched over the sample. First, a powder-free surgical glove with a gel coating was used to test blood contact. Second, a glove with a patented puncture indication system was used to test blood contact with a double-gloved hand. Third, 2 powder-free latex medical gloves of the same size and hand were combined for double gloving, again to test blood contact. Finally, we tested a glove with an integrated disinfectant on the inside. The punctures were carried out using diverse sharp surgical devices that were contaminated with (99)Tc-marked blood. The amount of blood contact was determined from the transmitted radioactivity. For the powder-free surgical glove with a gel coating, a mean volume of 0.048 microL of blood (standard error of the mean [SEM], 0.077 microL) was transferred in punctures with an automated lancet at a depth of 2.4 mm through 1 layer of latex. For the glove with an integrated disinfectant on the inside, the mean volume of blood transferred was 0.030 microL (SEM, 0.0056 microL) with a single glove and was 0.024 microL (SEM, 0.003 microL) with 2 gloves. For the glove with the patented puncture indication system, a mean volume of 0.024 microL (SEM, 0.003 microL) of blood was transferred. Double gloving or the use of a glove with disinfectant can result in a decrease in the volume of blood transferred. Therefore, the use of either of these gloving systems could help to minimize the risk of bloodborne infections for medical staff.
USDA-ARS?s Scientific Manuscript database
Russian dandelion (Taraxacum kok-saghyz) (TKS) produces high quality natural rubber (NR), cis-1,4 polyisoprene, by biosynthesis, and has been used historically as a source of NR during times of short supply or high prices for Hevea NR. The rubber is primarily located in root tissues along with appre...
Insights into rubber biosynthesis from transcriptome analysis of Hevea brasiliensis latex.
Chow, Keng-See; Wan, Kiew-Lian; Isa, Mohd Noor Mat; Bahari, Azlina; Tan, Siang-Hee; Harikrishna, K; Yeang, Hoong-Yeet
2007-01-01
Hevea brasiliensis is the most widely cultivated species for commercial production of natural rubber (cis-polyisoprene). In this study, 10,040 expressed sequence tags (ESTs) were generated from the latex of the rubber tree, which represents the cytoplasmic content of a single cell type, in order to analyse the latex transcription profile with emphasis on rubber biosynthesis-related genes. A total of 3,441 unique transcripts (UTs) were obtained after quality editing and assembly of EST sequences. Functional classification of UTs according to the Gene Ontology convention showed that 73.8% were related to genes of unknown function. Among highly expressed ESTs, a significant proportion encoded proteins related to rubber biosynthesis and stress or defence responses. Sequences encoding rubber particle membrane proteins (RPMPs) belonging to three protein families accounted for 12% of the ESTs. Characterization of these ESTs revealed nine RPMP variants (7.9-27 kDa) including the 14 kDa REF (rubber elongation factor) and 22 kDa SRPP (small rubber particle protein). The expression of multiple RPMP isoforms in latex was shown using antibodies against REF and SRPP. Both EST and quantitative reverse transcription-PCR (QRT-PCR) analyses demonstrated REF and SRPP to be the most abundant transcripts in latex. Besides rubber biosynthesis, comparative sequence analysis showed that the RPMPs are highly similar to sequences in the plant kingdom having stress-related functions. Implications of the RPMP function in cis-polyisoprene biosynthesis in the context of transcript abundance and differential gene expression are discussed.
Prior, Yeliz; Sutton, Chris; Cotterill, Sarah; Adams, Jo; Camacho, Elizabeth; Arafin, Nazina; Firth, Jill; O'Neill, Terence; Hough, Yvonne; Jones, Wendy; Hammond, Alison
2017-05-30
Arthritis gloves are regularly provided as part of the management of people with rheumatoid arthritis (RA) and undifferentiated (early) inflammatory arthritis (IA). Usually made of nylon and elastane (i.e. Lycra®), these arthritis gloves apply pressure with the aims of relieving hand pain, stiffness and improving hand function. However, a systematic review identified little evidence supporting their use. We therefore designed a trial to compare the effectiveness of the commonest type of arthritis glove provided in the United Kingdom (Isotoner gloves) (intervention) with placebo (control) gloves (i.e. larger arthritis gloves providing similar warmth to the intervention gloves but minimal pressure only) in people with these conditions. Participants aged 18 years and over with RA or IA and persistent hand pain will be recruited from National Health Service Trusts in the United Kingdom. Following consent, participants will complete a questionnaire booklet, then be randomly allocated to receive intervention or placebo arthritis gloves. Within three weeks, they will be fitted with the allocated gloves by clinical specialist rheumatology occupational therapists. Twelve weeks (i.e. the primary endpoint) after completing the baseline questionnaire, participants will complete a second questionnaire, including the same measures plus additional questions to explore adherence, benefits and problems with glove-wear. A sub-sample of participants from each group will be interviewed at the end of their participation to explore their views of the gloves received. The clinical effectiveness and cost-effectiveness of the intervention, compared to placebo gloves, will be evaluated over 12 weeks. The primary outcome measure is hand pain during activity. Qualitative interviews will be thematically analysed. This study will evaluate the commonest type of arthritis glove (Isotoner) provided in the NHS (i.e. the intervention) compared to a placebo glove. The results will help occupational therapists, occupational therapy services and people with arthritis make informed choices as to the value of arthritis gloves. If effective, arthritis gloves should become more widely available in the NHS to help people with RA and IA manage hand symptoms and improve performance of daily activities, work and leisure. If not, services can determine whether to cease supplying these to reduce service costs. ISRCTN Registry: ISRCTN25892131 Registered 05/09/2016.
Salomez, M; Subileau, M; Vallaeys, T; Santoni, S; Bonfils, F; Sainte-Beuve, J; Intapun, J; Granet, F; Vaysse, L; Dubreucq, É
2018-02-01
To characterize microbial communities present in natural rubber (NR) coagula from Hevea brasiliensis latex during maturation and identify microbial taxa (bacteria and fungi) having an impact on dry NR properties. Microbial community dynamics in NR coagula maturated under controlled conditions were compared and related with the evolution of dry NR properties. The pyrosequencing of 16S (119 837 effective reads) and 18S (131 879 effective reads) rRNA gene regions was performed on 21 samples covering different maturation times and two aeration conditions. Results showed a relatively high bacterial richness (Chao1 estimates of 200-1000) associated with significant bacterial dynamics. Lactic acid bacteria (LAB) were dominant in the first days of maturation. Then, in aerobic conditions, development of Actinobacteria represented by the family Microbacteriaceae was associated with alkalinization of the samples and a higher sensitivity of NR to thermo-oxidation as evaluated by its plasticity retention index (PRI). In anaerobiosis, the reduced development of bacteria, mostly LAB present, was associated with improved NR properties (higher initial plasticity P 0 and PRI). The involvement of micro-organisms in the evolution of dry NR properties during the maturation of NR coagula was confirmed. The importance of the structure and dynamics of microbial communities is specifically highlighted. Natural rubber is a key elastomer for the tyre industry and for a variety of other applications. The majority of raw NR is obtained by natural coagulation of H. brasiliensis latex under the activity of micro-organisms. An improved understanding of the microbial communities involved in the maturation of NR coagula may lead to an improvement in the production process of raw NR to provide a better consistency in NR quality. © 2017 The Society for Applied Microbiology.
Bucknor, A; Karthikesalingam, A; Markar, SR; Holt, PJ; Jones, I; Allen-Mersh, TG
2010-01-01
INTRODUCTION The prudent selection of surgical gloves can deliver significant efficiency savings. However, objective data are lacking to compare differences in cutaneous sensibility between competing gloves. Therefore, the present study examined the use of a single comparable model of sterile surgical glove from two competing providers, Gammex PF HyGrip® (Ansell Limited, Red Bank, NJ, USA) with Biogel® (Mölnlycke Health Care AB, Göteborg, Sweden). SUBJECTS AND METHODS Cutaneous pressure threshold, static and moving two-point discrimination were measured as indices of objective surgical glove performance in 52 blinded healthcare professionals. RESULTS The mean cutaneous pressure threshold was 0.0680 ± 0.0923 g for skin, 0.411 ± 0.661 g for Ansell gloves and 0.472 ± 0.768 g for Biogel gloves. Skin was significantly more sensitive than Ansell (P< 0.0001) or Biogel (P< 0.0001) gloves (Wilcoxon signed rank test). There was no statistical difference between Biogel and Ansell gloves (P = 0.359). There was no significant difference between static or moving 2-point discrimination of skin and Ansell gloves (P= 0.556, P = 0.617; Wilcoxon signed rank test), skin and Biogel gloves (P= 0.486, P= 0.437; Wilcoxon signed rank test) or Ansell and Biogel gloves (P= 0.843, P= 0.670; Wilcoxon signed rank test). CONCLUSIONS No demonstrable objective difference was found between competing gloves in the outcome measures of cutaneous sensibility and two-point discrimination. However, a difference in subjective preference was noted. Untested factors may underlie this discrepancy, and further research should employ more sophisticated measurements of surgical performance using competing models of surgical glove. PMID:21118618
Karino, Takeshi; Ikeda, Yuko; Yasuda, Yoritaka; Kohjiya, Shinzo; Shibayama, Mitsuhiro
2007-02-01
The microscopic structures of natural rubber (NR) and deproteinized NR (DPNR) were investigated by means of small-angle neutron scattering (SANS), small-angle X-ray scattering (SAXS), and atomic force microscopy (AFM). They were compared to those of isoprene rubber (IR), which is a synthetic analogue of NR in terms of chemical structure without any non-rubber components like proteins. Comparisons of the structure and mechanical properties of NR, DPNR, and IR lead to the following conclusions. (i) The well-known facts, for example, the outstanding green strength of NR and strain-induced crystallization, are due not much to the presence of proteins but to other components such as the presence of phospholipids and/or the higher stereoregularity of NR. It also became clear the naturally residing proteins accelerate the upturn of stress at low strain. The protein phases work as cross-linking sites and reinforcing fillers in the rubbery matrix. (ii) The microscopic structures of NR were successfully reproduced by SANS intensity functions consisting of squared-Lorentz and Lorentz functions, indicating the presence of inhomogeneities in bulk and thermal concentration fluctuations in swollen state, respectively. On the other hand, IR rubbers were homogeneous in bulk. (iii) The inhomogeneities in NR are assigned to protein aggregates of the order of 200 A or larger. Although these aggregates are larger in size as well as in volume fraction than those of cross-link inhomogeneities introduced by cross-linking, they are removed by deproteinization. (iv) Swelling of both NR and IR networks introduces gel-like concentration fluctuations whose mesh size is of the order of 20 A.
Potential use of autoinjector-packaged antidotes for treatment of pediatric nerve agent toxicity.
Henretig, Fred M; Mechem, Crawford; Jew, Rita
2002-10-01
We sought to determine the feasibility of discharging Mark 1 atropine and pralidoxime autoinjectors into small, sterile vials to facilitate the potential intramuscular injection of these antidotes, particularly pralidoxime, on a milligram per kilogram basis to small children. Autoinjectors were swabbed with isopropyl alcohol and then discharged into emptied, sterile, plastic 10-mL vials. This was repeated with the investigator garbed in standard personal protective gloves and full face mask and hood. The autoinjector injection surfaces were cultured. The autoinjectors were easily discharged into the vials without need for practice or special dexterity, even when investigators were garbed in protective gear. A small core of rubber stopper might be injected into the vial, and thus, the vial contents need to be withdrawn through a filter needle before reinjection. The autoinjector injection surfaces were sterile after alcohol swabbing. Autoinjectors might be a readily available source of concentrated pralidoxime for potential intramuscular use in small children.
[Prevention of work-related latex allergy].
Mehlum, I S
1998-09-10
Latex allergy has become a common work-related disease among health care workers. An increase in the use of latex gloves is the main reason for this. Measures to prevent sensitization and allergic reactions to latex can be implemented at various administrative levels: at national and international levels by regulations and recommendations, and by the implementation of various measures at the place of work. When to use gloves and what gloves to use are important issues, balancing barrier properties and the need to prevent infection with the need to prevent sensitization and allergic reactions to latex. There are great variations between allergen levels in different gloves, and this can be measured in different ways. Threshold levels are not specified, and latex gloves should not be considered devoid of allergenic potential. The Norwegian Labour Inspection Authority has carried out a survey on latex gloves, based on information from manufacturers and importers, and present this survey to guide glove users. We recommend powder-free gloves with low levels of latex allergens/leachable proteins, chemicals and endotoxins. There are several low-allergen gloves available on the Norwegian market, but for some gloves we lack important information.
Extra-Vehicular Activity (EVA) glove evaluation test protocol
NASA Technical Reports Server (NTRS)
Hinman-Sweeney, E. M.
1994-01-01
One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.
Permeability of latex gloves after contact with dental materials.
Richards, J M; Sydiskis, R J; Davidson, W M; Josell, S D; Lavine, D S
1993-09-01
The use of latex examination gloves in the dental office has become the standard of care. However, the effectiveness of gloves as a barrier after coming into contact with specific dental materials is still uncertain. To examine the effects of dental materials is still uncertain. To examine the effects of dental materials on latex, 100 latex examination glove finger tips were divided into 10 groups. Each group was manipulated in a different dental material for 15 minutes. Permeability was detected by the passage of herpes virus across the latex membrane, rinsed from the inner glove surface and titrated onto Vero cells. Significant virus leakage was discovered in gloves treated with acrylic monomer, chloroform, and orange solvent. Little virus leakage was noted in bleach, soap, and 30% phosphoric acid etchant treated gloves, and no virus leakage was found with composite resin, ethanol, formocresol, and water treated gloves. These data were supported with scanning electron micrographs taken of the treated glove samples and comparing with the controls. When certain dental materials are manipulated while wearing gloves, irreversible damage to the material occurs and may increase the practitioner's exposure to pathogens.
Liu, Peng; Wen, Hui; Harich, Franziska K; He, Changhuan; Wang, Lanxin; Guo, Xianming; Zhao, Jianwei; Luo, Aidong; Yang, Hongpei; Sun, Xiao; Yu, Yang; Zheng, Shaobo; Guo, Jing; Li, Li; Zhang, Li
2017-08-03
Over the last 4 decades, China has undergone major economic development, resulting in considerable impacts on its wildlife populations and habitats. It is essential to quantify the conflict between development and conservation to assist with policy-making because forestry policies and market trends affected indirectly the distribution of Asian elephants. Here, we mapped the historical distribution of elephants versus human land use. Elephant distributions appear to occur in unbroken natural forests only. However, over the 40-year period, the distribution ranges have become smaller and fragmented, with natural forest area also declining by 16%. The monoculture of cash trees is encroaching on natural forests. Over the past 10 years, rubber plantations have become concentrated in the south, with extensive natural forests and scattered rubber farms being converted to tea plantations, due to changes in governmental policies and product prices. Through mapping the spatial changes in the distribution of rubber and tea plantations, our study is expected to help local managers to incorporate the needs of endangered elephants through creating space when planning plantations, especially in Xishuangbanna and the south part of Pu'er. In conclusion, restoring elephant habitat and establishing ecological corridors are critical for the survival of elephants in this region.
Multilayer graphene rubber nanocomposites
NASA Astrophysics Data System (ADS)
Schartel, Bernhard; Frasca, Daniele; Schulze, Dietmar; Wachtendorf, Volker; Krafft, Bernd; Morys, Michael; Böhning, Martin; Rybak, Thomas
2016-05-01
Multilayer Graphene (MLG), a nanoparticle with a specific surface of BET = 250 m2/g and thus made of only approximately 10 graphene sheets, is proposed as a nanofiller for rubbers. When homogenously dispersed, it works at low loadings enabling the replacement of carbon black (CB), increase in efficiency, or reduction in filler concentration. Actually the appropriate preparation yielded nanocomposites in which just 3 phr are sufficient to significantly improve the rheological, curing and mechanical properties of different rubbers, as shown for Chlorine-Isobutylene-Isoprene Rubber (CIIR), Nitrile-Butadiene Rubber (NBR), Natural Rubber (NR), and Styrene-Butadiene Rubber (SBR). A mere 3 phr of MLG tripled the Young's modulus of CIIR, an effect equivalent to 20 phr of carbon black. Similar equivalents are observed for MLG/CB mixtures. MLG reduces gas permeability, increases thermal and electrical conductivities, and retards fire behavior. The later shown by the reduction in heat release rate in the cone calorimeter. The higher the nanofiller concentration is (3 phr, 5 phr, and 10 phr was investigated), the greater the improvement in the properties of the nanocomposites. Moreover, the MLG nanocomposites improve stability of mechanical properties against weathering. An increase in UV-absorption as well as a pronounced radical scavenging are proposed and were proved experimentally. To sum up, MLG is interesting as a multifunctional nanofiller and seems to be quite ready for rubber development.