Sample records for needle aspiration tbna

  1. Endobronchial ultrasound-guided transbronchial needle aspiration of thyroid: Report of two cases and systematic review of literature

    PubMed Central

    Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep

    2016-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005

  2. Impact of Rapid On-Site Cytological Evaluation (ROSE) on the Diagnostic Yield of Transbronchial Needle Aspiration During Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    PubMed

    Sehgal, Inderpaul Singh; Dhooria, Sahajal; Aggarwal, Ashutosh Nath; Agarwal, Ritesh

    2018-04-01

    Whether the use of rapid on-site cytologic evaluation (ROSE) increases the diagnostic yield of transbronchial needle aspiration (TBNA) remains unclear. This article is a systematic review of studies describing the utility of ROSE in subjects undergoing TBNA. The study included a systematic review of the PubMed, Embase, and Scopus databases for randomized controlled trials investigating the diagnostic yield of conventional transbronchial needle aspiration (c-TBNA) or endobronchial ultrasound (EBUS)-TBNA, with or without ROSE, in subjects with mediastinal lymphadenopathy. Five studies (618 subjects; two EBUS-TBNA, two c-TBNA, and one both) were identified. Overall, the studies were of good quality. The pooled risk difference (95% CI) of the diagnostic yield of EBUS-TBNA and c-TBNA was 0.04 (-0.01 to 0.09) and 0.12 (-0.08 to 0.33), respectively, suggesting no added benefit with ROSE. The use of ROSE during EBUS-TBNA (but not c-TBNA) resulted in significantly fewer needle passes (mean difference [95% CI], -1.1 [-2.2 to -0.005]; P < .001). There was no difference in the procedure time during EBUS-TBNA. The complication rate was significantly lower (OR [95% CI], 0.26 [0.10 to 0.71]; P = .009) when ROSE was used during c-TBNA due to fewer additional procedures required to make a diagnosis. There was evidence of heterogeneity in the studies involving c-TBNA but not EBUS-TBNA. There was no publication bias. The use of ROSE neither improved the diagnostic yield nor reduced the procedure time during TBNA. However, the use of ROSE was associated with fewer number of needle passes during EBUS-TBNA and overall lower requirement for additional bronchoscopy procedures during TBNA to make a final diagnosis. PROSPERO; No.: CRD42017058937; URL: www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  3. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    NASA Astrophysics Data System (ADS)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  4. Flexible needle with integrated optical coherence tomography probe for imaging during transbronchial tissue aspiration

    NASA Astrophysics Data System (ADS)

    Li, Jiawen; Quirk, Bryden C.; Noble, Peter B.; Kirk, Rodney W.; Sampson, David D.; McLaughlin, Robert A.

    2017-10-01

    Transbronchial needle aspiration (TBNA) of small lesions or lymph nodes in the lung may result in nondiagnostic tissue samples. We demonstrate the integration of an optical coherence tomography (OCT) probe into a 19-gauge flexible needle for lung tissue aspiration. This probe allows simultaneous visualization and aspiration of the tissue. By eliminating the need for insertion and withdrawal of a separate imaging probe, this integrated design minimizes the risk of dislodging the needle from the lesion prior to aspiration and may facilitate more accurate placement of the needle. Results from in situ imaging in a sheep lung show clear distinction between solid tissue and two typical constituents of nondiagnostic samples (adipose and lung parenchyma). Clinical translation of this OCT-guided aspiration needle holds promise for improving the diagnostic yield of TBNA.

  5. Comparison of 21-Gauge and 22-Gauge Aspiration Needle in Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E.; Ray, Cynthia; Greenhill, Sarah R.; Jimenez, Carlos A.; Filner, Joshua; Feller-Kopman, David

    2013-01-01

    Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. Methods: We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. Results: A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). Conclusions: There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle. PMID:23632441

  6. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  7. Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry.

    PubMed

    Yarmus, Lonny B; Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E; Ray, Cynthia; Greenhill, Sarah R; Jimenez, Carlos A; Filner, Joshua; Feller-Kopman, David

    2013-04-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle.

  8. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil*,**

    PubMed Central

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients. PMID:25750671

  9. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil.

    PubMed

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  10. Use of an Additional 19-G EBUS-TBNA Needle Increases the Diagnostic Yield of EBUS-TBNA.

    PubMed

    Garrison, Garth; Leclair, Timothy; Balla, Agnes; Wagner, Sarah; Butnor, Kelly; Anderson, Scott R; Kinsey, C Matthew

    2018-06-12

    Although endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has an excellent diagnostic yield, there remain cases where the diagnosis is not obtained. We hypothesized that additional sampling with a 19-G EBUS-TBNA needle may increase diagnostic yield in a subset of cases where additional tissue sampling was required. Indications for use of the 19-G needle following 22-G sampling with rapid on-site cytologic examination were: (1) diagnostic uncertainty of the on-site cytopathologist (eg, nondiagnostic, probable lymphoma, etc.), (2) non-small cell lung cancer with probable need for molecular genetic and/or PD-L1 testing, or (3) need for a larger tissue sample for consideration of inclusion in a research protocol. A 19-G EBUS-TBNA needle was utilized following standard sampling with a 22-G needle in 48 patients (50 sites) during the same procedure. Although the diagnostic yield between the needles was equivalent, the concordance rate was only 83%. The 19-G determined a diagnosis in 4 additional patients (8%) and provided additional histopathologic information in 6 other cases (12%). Conversely, in 3 cases (6%) diagnostic information was provided only by the 22-G needle. Compared with 22-G EBUS-TBNA alone, sampling with both the 22- and 19-G EBUS needles resulted in an increase in diagnostic yield from 92% to 99% (P=0.045) and a number needed to sample of 13 patients to provide one additional diagnosis. There were no significant complications. In select cases where additional tissue may be needed, sampling with a 19-G EBUS needle following standard aspiration with a 22-G needle results in an increase in diagnostic yield.

  11. Risks and benefits in treatment of mediastinal abscess by endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan

    2017-07-01

    Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.

  12. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    PubMed

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  13. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using 19-G Needle for Sarcoidosis.

    PubMed

    Balwan, Akshu

    2018-05-16

    Flexible bronchoscopy with endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is increasingly being used to obtain pathology specimens for diagnosis of sarcoidosis. There is wide variation in reported diagnostic yield in literature. New TBNA needles are available in the market but data are lacking about their diagnostic yield especially for sarcoidosis. This study reports the diagnostic yield of bronchoscopy with EBUS-TBNA using ViziShot FLEX 19-G needle in a series of patients with suspected sarcoidosis. This is a retrospective chart review for diagnostic yield of the 19-G EBUS-TBNA needle for suspected sarcoidosis. Eighty-six EBUS bronchoscopies were performed, 15 were done with clinical suspicion of sarcoidosis. The 19-G needle was used for all cases of suspected sarcoidosis. The procedure was diagnostic of sarcoidosis in 14 (93.3%) patients by TBNA with 1 nondiagnostic bronchoscopy. Procedural diagnostic yield was 93.3%. Eighty-five percent (28/33) of sampled lymph nodes were positive for noncaseating granulomas. The yield of transbronchial lung biopsy (TBLB) and endobronchial lung biopsy was 38% (5/13) and 43% (6/14), respectively. TBLB and endobronchial lung biopsy did not add to the diagnostic yield of the procedure. No significant adverse events were noted. This series reports a higher diagnostic yield than most other published studies and opens platform for direct comparison of each available needle. It also adds to the safety data for this larger needle. In addition, it raises doubt into utility of TBLB for diagnosis of sarcoidosis, which can increase the procedural complications.

  14. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  15. Tracheobronchial puncture-site nodular reaction (TPNR) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): Systematic review of case reports.

    PubMed

    Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  16. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  17. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a concise review.

    PubMed

    Aziz, Fahad

    2012-09-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) offers a minimally invasive alternative to mediastinoscopy with additional access to the hilar nodes, a better safety profile, and it removes the costs and hazards of theatre time and general anesthesia with comparable sensitivity, although the negative predictive value of mediastinoscopy (and sample size) is greater. EBUS- TBNA also obtains larger samples than conventional TBNA, has superior performance and theoretically is safer, allowing real-time sampling under direct vision. It can also have predictive value both in sonographic appearance of the nodes and histological characteristics. EBUS-TBNA is therefore indicated for NSCLC staging, diagnosis of lung cancer when there is no endobronchial lesion, and diagnosis of both benign (especially tuberculosis and sarcoidosis) and malignant mediastinal lesions. The procedure is different than for flexible bronchoscopy, takes longer, and requires more training. EBUS-TBNA is more expensive than conventional TBNA but can save costs by reducing the number of more costly mediastinoscopies. In the future, endobronchial ultrasound may have applications in airways disease and pulmonary vascular disease.

  18. Realistic and affordable lo-fidelity model for learning bronchoscopic transbronchial needle aspiration.

    PubMed

    Goldberg, Robert; Colt, Henri G; Davoudi, Mohsen; Cherrison, Larry

    2009-09-01

    Transbronchial needle aspiration (TBNA) is used to sample mediastinal abnormalities and lymph node stations for diagnostic purposes and lung cancer staging. The procedure is underused, operator dependent, and reputed to have a steep learning curve. Other difficulties arise from a bronchoscopist's failure to insert the needle satisfactorily into the target node. The purpose of this study was to evaluate the realism and helpfulness of a lo-fidelity, easily constructed hybrid model used for learning and practicing TBNA. The model is constructed by attaching a porcine tracheobronchial tree to a Laerdal Airway Model mounted on polyvinyl chloride (PVC) piping. Twelve individuals with various levels of bronchoscopy training and experience were given a 15-min introductory PowerPoint presentation on TBNA strategy and planning, execution, and response to complications. Participants then practiced TBNA alone and with guidance, aided by an assistant, as many times as individually necessary to feel comfortable with the procedure. A five-point Likert scale 8-item questionnaire was then completed. Participants were unanimously positive about their experience (mean scores 4.25-4.91). The model was realistic, provided increased comfort with TBNA techniques, and allowed practice of communication skills. This realistic, affordable, and easily constructed hybrid lo-fidelity airway model allows beginner and experienced bronchoscopists opportunities to learn and practice basic TBNA techniques and team communication skills without placing patients at risk.

  19. Utility of conventional transbronchial needle aspiration with rapid on-site evaluation (c-TBNA-ROSE) at a tertiary care center with endobronchial ultrasound (EBUS) facility

    PubMed Central

    Madan, Neha Kawatra; Madan, Karan; Jain, Deepali; Walia, Ritika; Mohan, Anant; Hadda, Vijay; Mathur, Sandeep; Iyer, Venkateswaran K; Khilnani, Gopi C; Guleria, Randeep

    2016-01-01

    Background: Conventional transbronchial needle aspiration (c-TBNA) is an underutilized bronchoscopic modality. Endobronchial ultrasound (EBUS) guided-TBNA though efficacious is an expensive modality, facilities of which are available at only limited centers. c-TBNA is cost-effective and has potential for wide utilization especially in resource-limited settings. Rapid on-site evaluation (ROSE) improves the yield of c-TBNA. Materials and Methods: A retrospective review of the bronchoscopy records (May 2012 to July 2014) was performed. The patients who underwent c-TBNA with ROSE were included in the study and their clinical details were extracted. Convex probe EBUS-TBNA was being regularly performed during the study period by the operators performing c-TBNA. Results: c-TBNA with ROSE was performed in 41 patients with mean age of 42.4 (16.2) years. The most frequently sampled node stations (>90% patients) were the subcarinal and lower right paratracheal. Representative samples could be obtained in 33 out of the 41 patients (80.4%). c-TBNA was diagnostic in 32 [tuberculosis (TB)-8, sarcoidosis-9, and malignancy-15] patients out of the 41 patients. The overall diagnostic yield (sensitivity) of c-TBNA with ROSE was 78%. Mean procedure duration was 18.4 (3.1) min and there were no procedural complications. Conclusion: c-TBNA with ROSE is a safe, efficacious, and cost-effective bronchoscopic modality. When it was performed by operators routinely performing EBUS-TBNA, diagnostic yields similar to that of EBUS-TBNA can be obtained. Even at the centers where EBUS facilities are available, c-TBNA should be routinely performed. PMID:27011437

  20. Endobronchial ultrasound-guided transbronchial needle aspiration of pulmonary artery tumors: A systematic review (with video).

    PubMed

    Harris, Kassem; Modi, Kush; Kumar, Abhishek; Dhillon, Samjot Singh

    2015-01-01

    Convex probe endobronchial ultrasound (CP-EBUS) was originally introduced as a diagnostic and staging tool for lung cancer and subsequently utilized for diagnosis of other malignant and benign mediastinal diseases such as melanoma, lymphoma, and sarcoidosis. More recently, CP-EBUS has been successfully used for the visualization and diagnosis of pulmonary emboli and other vascular lesions including primary and metastatic pulmonary artery (PA) tumors. In this review, we will underline the role of EBUS-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of pulmonary arterial tumors such as sarcomas and tumor emboli. We will concisely discuss the clinical applications of EBUS-TBNA and the types of pulmonary arterial tumors and their different diagnostic modalities. We searched the Cochrane Library and PubMed from 2004 to 2014 to provide the most comprehensive review. Only 10 cases of EBUS-TBNA for intravascular lesions were identified in the literature. Although many cases of EBUS and EUS-guided transvascular tumor biopsies were described in the literature, there were no reported cases of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for intravascular tumor biopsies. Except for one paper, all cases were published as case reports.

  1. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial

    PubMed Central

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-01-01

    Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage and was admitted to hospital. Interpretation Transbronchial needle aspiration guided by endobronchial ultrasound should be considered as the initial investigation for patients with suspected lung cancer, because it reduces the time to treatment decision compared with conventional diagnosis and staging techniques. Funding UK Medical Research Council. PMID:25660225

  2. EBUS-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration

    PubMed Central

    Bramley, Kyle; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Homer, Robert; Puchalski, Jonathan

    2016-01-01

    Background EBUS-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, when larger “core” biopsy samples of malignant tissue are required, TBNA may not suffice. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsies (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. Methods Fifty unselected patients undergoing convex probe EBUS were prospectively enrolled. Under EBUS guidance, all lymph nodes ≥ 1 cm were sequentially biopsied using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported on a per-patient basis. Results There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). For analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis was based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis was based only on TBNA samples. In some cases only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. Conclusions The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided specimens for clinical trials of malignancy when needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. PMID:26912301

  3. Endobronchial Ultrasound-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration.

    PubMed

    Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T

    2016-05-01

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  5. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Increases the Yield of Transbronchial Lung Biopsy for the Evaluation of Peribronchial Lesions

    PubMed Central

    Chen, Cheng; Mu, Chuan-Yong; Su, Mei-Qin; Mao, Jing-Yu; Zhu, Ye-Han; Huang, Jian-An

    2017-01-01

    Background: Due to absence of visible endobronchial target, the diagnostic yield of flexible bronchoscopy for peribronchial lesions has been unsatisfactory. Convex probe endobronchial ultrasound (CP-EBUS) has allowed for performing real-time transbronchial needle aspiration (TBNA) of enlarged hilar and mediastinal lymph nodes and therefore could also be used as a means of diagnosing proximal peribronchial lesions. Methods: We retrospectively analyzed the results related to 72 patients who underwent CP-EBUS for peribronchial lesions without endobronchial involvement and adjacent to three-grade bronchi based on chest computed tomography (CT) scan. We recorded the images during EBUS as well as the diagnostic results of TBNA and conventional-transbronchial lung biopsy/brush (C-TBLB/b), and final diagnoses were based on pathologic analysis and follow-up. Results: In all cases, the mass was able to be identified using EBUS in 97.2% patients (70/72) who were performed with EBUS-TBNA + C-TBLB/b. Sixty-six patients had a final diagnosis, 80.0% patients (56/70) had malignancies, and 14.3% patients (10/70) had benign disease. In malignancies, the diagnostic yield of C-TBLB/b was 57.1% (32/56) and in EBUS-TBNA was 85.7% (48/56), whereas pathologic diagnosis reached 94.6% when EBUS-TBNA was combined with C-TBLB/b. C-TBLB/b + EBUS-TBNA also exhibited stronger potency of histolytic diagnosis for malignancies than either EBUS-TBNA or C-TBLB/b alone. Furthermore, there are data supporting the value of EBUS-TBNA for the diagnosis of benign lung disease. Conclusion: The combined endoscopic approach with EBUS-TBNA and C-TBLB/b is an accurate and effective method for the evaluation of peribronchial lesions, with better results than using each technique alone. PMID:28051017

  6. Relationship between endobronchial ultrasound‐guided (EBUS)‐transbronchial needle aspiration utility and computed tomography staging, node size at EBUS, and positron emission tomography scan node standard uptake values: A retrospective analysis

    PubMed Central

    Marchand, Clare

    2017-01-01

    Background Endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) diagnoses and stages mediastinal lymph node pathology. This retrospective study determined the relationship between EBUS‐TBNA utility and non‐small cell lung cancer (NSCLC) stage, lymph node size, and positron emission tomography (PET) standard uptake values (SUV), and the utility of neck ultrasound in bulky mediastinal disease. Methods Data of 284 consecutive patients who had undergone EBUS‐TBNA was collected. Two hundred patients had suspected NSCLC, with 148 confirmed NSCLC cases. The diagnostic utility of EBUS‐TBNA was determined according to NSCLC stage, EBUS lymph node size, PET SUV, use in distal metastases, and mutation testing. The utility of neck ultrasound for N3 disease was calculated in patients with bulky mediastinal disease. Results EBUS‐TBNA was well tolerated with 97% sensitivity in distant metastatic disease, avoiding the need for distal metastases biopsy in 81% of cases. It had equivalent diagnostic accuracy in all NSCLC stages and in lymph nodes <10 mm, <20 mm or >20 mm (sensitivity >92% in all cases), with no mutation testing failures. EBUS‐TBNA had 33% sensitivity in PET indolent (SUV < 4) nodes and 79% sensitivity in PET active nodes (SUV > 4). EBUS‐TBNA diagnosed 12 cases of lymphoma without flow cytometry. Conclusions The use of EBUS‐TBNA meant that distant metastatic biopsy was avoided in 81% of cases, performing well irrespective of cancer stage, node size, and facilitating mutation testing. Neck ultrasound failed to detect N3 disease in patients with bulky mediastinal disease. EBUS‐TBNA had a sensitivity of 33% for metastases in PET negative nodes, highlighting PET limitations. PMID:28436173

  7. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration versus Standard Bronchoscopic Modalities for Diagnosis of Sarcoidosis: A Meta-analysis

    PubMed Central

    Hu, Li-Xing; Chen, Ru-Xuan; Huang, Hui; Shao, Chi; Wang, Ping; Liu, Yong-Zhe; Xu, Zuo-Jun

    2016-01-01

    Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an effective technique used to precisely detect enlarged mediastinal lymph nodes. The efficacy of EBUS-TBNA versus standard modalities for the diagnosis of sarcoidosis remains to be elucidated. In this meta-analysis, we compared the efficacies of these methods. Methods: We searched PubMed, Embase, The Cochrane Library, Wanfang, Cpvip, CNKI, and the bibliographies of the relevant references. We analyzed the data obtained with Revman 5.2 (Nordic Cochrane Center, Copenhagen, Denmark) and Stata 12.0 software (Stata Corporation, College Station, TX, USA). The Mantel-Haenszel method was used to calculate the pooled odds ratio (OR) and 95% confidence intervals (CIs). Results: Sixteen studies with a total of 1823 participants met the inclusion criteria, and data were extracted regarding the diagnostic yield of each approach. The ORs for EBUS-TBNA versus transbronchial lung biopsy (TBLB) for the diagnosis of sarcoidosis ranged from 0.26 to 126.58, and the pooled OR was 5.89 (95% CI, 2.20–15.79, P = 0.0004). These findings indicated that EBUS-TBNA provided a much higher diagnostic yield than TBLB. The pooled OR for EBUS-TBNA + TBLB + endobronchial biopsy (EBB) versus TBNA + TBLB + EBB was 1.54 (95% CI, 0.61–3.93, P = 0.36), implying that there was no significant difference between their diagnostic yields. However, clinical heterogeneity was reflected in the nature of the studies and in the operative variables. Conclusions: The results of this meta-analysis suggest that EBUS-TBNA + TBLB + EBB could be used for the diagnosis of sarcoidosis, if available. At medical centers without EBUS-TBNA, TBNA + TBLB + EBB could be used instead. PMID:27364799

  8. Transbronchial needle aspiration cytology (TBNA) in endobronchial lesions: a valuable technique during bronchoscopy in diagnosing lung cancer and it will decrease repeat bronchoscopy.

    PubMed

    Shital, Patil; Rujuta, Ayachit; Sanjay, Mundkar

    2014-05-01

    Lung cancer is the leading cause of cancer deaths around the world. Globally, lung cancer is the largest contributor to new cancer diagnosis and to death from cancer. Various conventional diagnostic techniques (CDTs) such as endobronchial forcep biopsy (FB), bronchial washing (BW) and bronchial brushing (BB), and transbronchial needle aspiration cytology (TBNA) are employed during fiber-optic bronchoscopy. This is a prospective study conducted between June 2012 and September 2013 at Bronchoscopy unit of MIMSR Medical College Latur, India, to find the role of TBNA in exophytic endobronchial lesions in confirming the diagnosis of lung cancer and to find additive yield over other techniques such as BB, BW and FB, and included 150 patients on the basis of clinical and radiological features of malignancy. In exophytic endobronchial lesions, predominant endoscopic findings were cauliflower, polypoidal-like or nodular or multinodular endobronchial growth. TBNA, FB, BB and BW were performed in all the cases during FOB. Histopathological and cytological examinations of specimens were performed at Pathology department. The statistical analysis was done using chi-square test. Total 150 patients, between age group 24-80 years, mean age was 57.93 years, male population constitutes 86.17 % of total. 76.14 % cases were smoker of them 61.87 % cases having history of >40 pack years. Commoner symptoms were cough (91.33 %), hemoptysis (54.00 %) and chest pain (46.66 %), and mass lesion (40.66 %), hilar opacity (31.33 %) and collapse segmental/lobar (29.33 %) were commoner radiological abnormalities. Yield of TBNA, CDT and TBNA plus CDT in exophytic lesions is 60.66, 79.33 and 84.66 %, respectively, in diagnosis of lung malignancies (P < 0.001). Sensitivity of forcep biopsy and TBNA in diagnosing lung malignancy was 88.18 and 71.65 %, respectively (P < 0.01). FOB-related hypoxemia documented in two cases and minor bleeding in six cases. Other complications such as significant bleeding, pneumothorax and death were not seen. Minor bleeding was seen with forcep biopsy mainly in 4.0 % cases. TBNA has decreased repeat procedure, decreases cost for diagnosis. IHC on TBNA specimens had increased histological-type confirmation. Transbronchial needle aspiration is a beneficial, safe and minimally invasive bronchoscopic technique with insignificant side effect in the diagnosis bronchogenic carcinoma. TBNA considered safe, especially when fleshy vascular endobronchial growth is present and risk of bleeding is high with forcep biopsy. Inadequate tissue sampling due to the presence of necrosis, blood clot over the lesion and formation of crush artifacts by FB makes TBNA valuable in these lesions. TBNA will definitely decrease need for repeat bronchoscopy.

  9. Endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of non-lymph node thoracic lesions

    PubMed Central

    Yang, Huizhen; Zhao, Heng; Garfield, David H.; Teng, Jiajun; Han, Baohui; Sun, Jiayuan

    2013-01-01

    AIMS: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has shown excellent diagnostic capabilities for mediastinal and hilar lymphadenopathy. However, its value in thoracic non-lymph node lesions is less clear. This study was designed to assess the value of EBUS-TBNA in distinguishing malignant from benign thoracic non-lymph node lesions. METHODS: From October 2009 to August 2011, 552 patients underwent EBUS-TBNA under local anesthesia and with conscious sedation. We retrospectively reviewed 81 of these patients who had tracheobronchial wall-adjacent intrapulmonary or isolated mediastinal non-lymph node lesions. On-site cytological evaluation was not used. Immunohistochemistry (IHC) was performed to distinguish the origin or type of malignancy when necessary. RESULTS: EBUS-TBNA was performed in 68 tracheobronchial wall-adjacent intrapulmonary and 13 isolated mediastinal non-lymph node lesions. Of the 81 patients, 77 (95.1%, 60 malignancies and 17 benignancies) were diagnosed through EBUS-TBNA, including 57 primary lung cancers, 2 mediastinal tumors, 1 pulmonary metastatic adenocarcinoma, 7 inflammation, 5 tuberculosis, 3 mediastinal cysts, 1 esophageal schwannoma, and 1 focal fibrosis. There were four false-negative cases (4.9%). Of the 60 malignancies, there were 9 (15.0%) which originally had no definite histologic origin or type. Thus, IHC was performed, with 7 (77.8%) being subsequently confirmed. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBUS-TBNA in distinguishing malignant from benign lesions were 93.4% (60/64), 100% (17/17), 100% (60/60), 81.0% (17/21), and 95.1% (77/81), respectively. CONCLUSION: EBUS-TBNA is a safe procedure with a high sensitivity for distinguishing malignant from benign thoracic non-lymph node lesions within the reach of EBUS-TBNA, with IHC usually providing a more definitive diagnosis. PMID:23439919

  10. The role of endobronchial ultrasound versus mediastinoscopy for non-small cell lung cancer.

    PubMed

    Czarnecka-Kujawa, Katarzyna; Yasufuku, Kazuhiro

    2017-03-01

    This review provides an update on the current role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and mediastinoscopy (Med) in assessment of patients with non-small cell lung cancer (NSCLC). Invasive mediastinal lymph node (LN) staging is the major application for both of these techniques. Up until recently, Med was the gold standard for invasive mediastinal LN staging in NSCLC. However, EBUS-TBNA has shown to be equivalent, and in some studies better than Med for invasive staging of lung cancer. EBUS-TBNA offers access to N1 LNs and development of the thin convex probe EBUS (TCP-EBUS) will expand EBUS-TBNA access from the paratracheal region and central airways to more distal parabronchial regions allowing for more extensive N1 LN assessment and sampling more distal lung tumors. EBUS-TBNA is more cost-effective than Med and it is currently recommended as the test of first choice for invasive mediastinal LN staging in lung cancer. Confirmatory Med should be performed selectively in patients with high pretest probability of metastatic disease. Addition of esophageal ultrasound fine needle aspiration (EUS-FNA) may increase diagnostic yield of EBUS-TBNA mediastinal staging. Both Med and EBUS-TBNA can be used in primary lung cancer diagnosis, restaging of the mediastinum following neoadjuvant therapy and in diagnosis of lung cancer recurrence. In the future, a combination of EBUS-TBNA with or without EUS-FNA and Med is most likely going to provide the most optimal invasive assessment of the mediastinum in patients with lung cancer. The decision on test choice and sequence should be made on a case-by-case basis and factoring in local resources and expertise.

  11. Combined cumulative sum (CUSUM) and chronological environmental analysis as a tool to improve the learning environment for linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) trainees: a pilot study.

    PubMed

    Norisue, Yasuhiro; Tokuda, Yasuharu; Juarez, Mayrol; Uchimido, Ryo; Fujitani, Shigeki; Stoeckel, David A

    2017-02-07

    Cumulative sum (CUSUM) analysis can be used to continuously monitor the performance of an individual or process and detect deviations from a preset or standard level of achievement. However, no previous study has evaluated the utility of CUSUM analysis in facilitating timely environmental assessment and interventions to improve performance of linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aim of this study was to evaluate the usefulness of combined CUSUM and chronological environmental analysis as a tool to improve the learning environment for EBUS-TBNA trainees. This study was an observational chart review. To determine if performance was acceptable, CUSUM analysis was used to track procedural outcomes of trainees in EBUS-TBNA. To investigate chronological changes in the learning environment, multivariate logistic regression analysis was used to compare several indices before and after time points when significant changes occurred in proficiency. Presence of an additional attending bronchoscopist was inversely associated with nonproficiency (odds ratio, 0.117; 95% confidence interval, 0-0.749; P = 0.019). Other factors, including presence of an on-site cytopathologist and dose of sedatives used, were not significantly associated with duration of nonproficiency. Combined CUSUM and chronological environmental analysis may be useful in hastening interventions that improve performance of EBUS-TBNA.

  12. Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal staging in lung cancer*

    PubMed Central

    Fernández-Bussy, Sebastián; Labarca, Gonzalo; Canals, Sofia; Caviedes, Iván; Folch, Erik; Majid, Adnan

    2015-01-01

    OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions. PMID:26176519

  13. Molecular Testing for Targeted Therapy in Advanced Non-Small Cell Lung Cancer: Suitability of Endobronchial Ultrasound Transbronchial Needle Aspiration.

    PubMed

    Casadio, Chiara; Guarize, Juliana; Donghi, Stefano; Di Tonno, Clementina; Fumagalli, Caterina; Vacirca, Davide; Dell'Orto, Patrizia; De Marinis, Filippo; Spaggiari, Lorenzo; Viale, Giuseppe; Barberis, Massimo

    2015-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure that has revolutionized the diagnosis and staging of lung cancer. The goal of the present study was to investigate the yield and applicability of molecular testing in the specimens obtained by EBUS-TBNA from patients with advanced non-small cell lung cancer (NSCLC), comparing the results with a series of patients who underwent diagnostic surgical procedures in the same institution. The study followed 306 consecutive patients with clinically diagnosed primary lung cancer who had the EBUS-TBNA procedure. EGFR and KRAS mutations were evaluated on cytologic specimens by Sanger sequencing and Cobas real-time polymerase chain reaction, whereas ALK rearrangement was tested by fluorescence in situ hybridization. The results were compared with those obtained from a series of 1,000 NSCLC surgical samples routinely analyzed. Molecular testing was possible in 96.9% of the samples obtained by EBUS-TBNA. EGFR (exons 18-21) mutations were found in 16.9%, KRAS mutation (exons 2-3) in 31.6%, and ALK rearrangement in 3.9% of the cases. In the surgical series, the mutations' distribution were 14.8%, 29.0%, and 3.4%, respectively. There were no statistical differences between the two series. Our study demonstrates that EBUS-TBNA can be effectively used not just for diagnosis but also for complete mutational testing. Copyright© by the American Society for Clinical Pathology.

  14. Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy.

    PubMed

    Asano, Fumihiro; Aoe, Motoi; Ohsaki, Yoshinobu; Okada, Yoshinori; Sasada, Shinji; Sato, Shigeki; Suzuki, Eiichi; Semba, Hiroshi; Fukuoka, Kazuya; Fujino, Shozo; Ohmori, Kazumitsu

    2013-05-10

    With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.

  15. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    PubMed

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  16. Greater physician involvement improves coding outcomes in endobronchial ultrasound-guided transbronchial needle aspiration procedures.

    PubMed

    Pillai, Anilkumar; Medford, Andrew R L

    2013-01-01

    Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.

  17. [Results of endobronchial ultrasound-guided transbronchial needle aspiration in lung cancer: importance of the lymph node involvement prevalence].

    PubMed

    De Dominicis, F; Fourdrain, A; Iquille, J; Toublanc, B; François, G; Basille, D; Monconduit, J; Merlusca, G; Jounieaux, V; Andrejak, C; Berna, P

    2015-08-01

    We studied the non-surgical invasive staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and we detailed the differences of our series, in order to understand the criteria allowing to achieve a better performance. Retrospective observational study conducted between 2007 and 2011, including all patients with proven NSCLC who underwent EBUS-TBNA. For the 92 EBUS-TBNA performed, we found a sensitivity of 78%, a specificity of 93%, a positive predictive value (PPV) of 98%, a negative predictive value (NPV) of 45%, an accuracy of 80% and a prevalence of lymph node involvement at 84%. A learning curve has been demonstrated and a significant difference was found based on the number of punctures by procedure (P=0.02) or on histological type (P=0.02). By analyzing the data of the literature, we have been able to demonstrate that the accuracy and the negative predictive value are correlated with the prevalence. If we take into account this correlation, we can consider the results of our study close to those of the literature. We highlighted a number of criteria that will influence the diagnostic yield of EBUS-TBNA. While some have already been described, other criteria such as histological type or patient selection criteria are less discussed. The key point is the correlation between the prevalence and EBUS-TBNA results. Results of the assessment of lymph node involvement techniques should be interpreted according to the prevalence of lymph node involvement. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  18. Molecular Nodal Staging Using miRNA Expression in Lung Cancer Patients by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration.

    PubMed

    Inage, Terunaga; Nakajima, Takahiro; Itoga, Sakae; Ishige, Takayuki; Fujiwara, Taiki; Sakairi, Yuichi; Wada, Hironobu; Suzuki, Hidemi; Iwata, Takekazu; Chiyo, Masako; Yoshida, Shigetoshi; Matsushita, Kazuyuki; Yasufuku, Kazuhiro; Yoshino, Ichiro

    2018-06-13

    The limited negative predictive value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has often been discussed. The aim of this study was to identify a highly sensitive molecular biomarker for lymph node staging by EBUS-TBNA. Five microRNAs (miRNAs) (miR-200a, miR-200b, miR-200c, miR-141, and let-7e) were selected as biomarker candidates for the detection of nodal metastasis in a miRNA expression analysis. After having established a cutoff level of expression for each marker to differentiate malignant from benign lymph nodes among surgically dissected lymph nodes, the cutoff level was applied to snap-frozen EBUS-TBNA samples. Archived formalin-fixed paraffin- embedded (FFPE) samples rebiopsied by EBUS-TBNA after induction chemoradiotherapy were also analyzed. The expression of all candidate miRNAs was significantly higher in metastatic lymph nodes than in benign ones (p < 0.05) among the surgical samples. miR-200c showed the highest diagnostic yield, with a sensitivity of 95.4% and a specificity of 100%. When the cutoff value for miR-200c was applied to the snap-frozen EBUS-TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.4, 81.8, 95.0, 90.0, and 94.0%, respectively. For restaging FFPE EBUS- TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 60.0, 80.0, 100, and 84.6%, respectively. Among the restaged samples, 4 malignant lymph nodes were false negative by EBUS-TBNA, but they were accurately identified by miR-200c. miR-200c can be used as a highly sensitive molecular staging biomarker that will enhance nodal staging of lung cancer. © 2018 S. Karger AG, Basel.

  19. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.

  20. Vintage meets contemporary: Use of rigid TBNA in the era of real-time imaging - first report from India.

    PubMed

    Khan, Ajmal; Nath, Alok; Lal, Hira; Krishnani, Narendra; Agarwal, Aarti

    2018-01-01

    In the modern era, real-time imaging-guided transbronchial needle aspiration (TBNA) has completely replaced the traditional surgical approaches to sample the mediastinal lesions for diagnosis and cancer staging. However, there is a limited role of these innovations in the presence of critical airway narrowing due to a further decrease in cross-sectional area of the airway proportionate to the outer diameters of the scope. Rigid TBNA with airway control by rigid bronchoscopy is one alternative which can be used for mediastinal sampling when modern technique is impracticable. Herein, we report the use of rigid TBNA, an underutilized old method to sample the mediastinal lesion in a patient with severe orthopnea secondary to tracheal compression by mediastinal mass.

  1. Comparison of Sample Adequacy and Diagnostic Yield of 19- and 22-G EBUS-TBNA Needles.

    PubMed

    Chaddha, Udit; Ronaghi, Reza; Elatre, Waafa; Chang, Ching-Fei; Mahdavi, Ramyar

    2018-05-16

    The 2016 CHEST consensus guidelines recommend use of either 21- or 22-G needles for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). We decided to prospectively compare sample adequacy and diagnostic yield of the 19-G with the 22-G EBUS needle, hypothesizing that a larger gauge difference might magnify the differences between 2 needle sizes. Twenty-seven patients undergoing EBUS-TBNA at our institution were evaluated. All cases were performed by a single operator formally trained in interventional pulmonology. Both Olympus 19- and 22-G needles were used at each lymph node station in an alternating manner. Rapid on-site cytology evaluation was used and a separate cell block was prepared for each needle at each station. Fifty-six lymph nodes were analyzed. Diagnoses included cancer (36%, including 1 lymphoma), reactive lymphoid tissue (53%), and sarcoidosis (11%). One hundred sixty-two and 163 passes were made with the 22- and 19-G needle, respectively. Sample adequacy was 73% and 46% with the 22 and 19-G needle, respectively (P<0.001). Significantly fewer passes were bloody with the 22-G compared with the 19-G needle (19% vs. 59%; P<0.001). Diagnostic yield was not different between the 22- and 19-G needles (95% vs. 93%; P=0.62). In addition to no difference in diagnostic yield, the 19-G needle yielded samples that were frequently less adequate and more often bloody compared with the 22-G needle. Despite the larger caliber lumen, we conclude that the 19-G needle does not confer a diagnostic advantage.

  2. Utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration in patients with mediastinal and hilar lymphadenopathy: Western region experience.

    PubMed

    Aljohaney, Ahmed A

    2018-01-01

    The aim of the study was to evaluate the clinical utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with mediastinal and hilar lymphadenopathy and to explicitly describe the utility of this procedure in patient's outcome. A retrospective review and analysis was conducted on 52 patients with mediastinal or hilar lymphadenopathy who underwent EBUS-TBNA from June 2012 to June 2016. All the patients were evaluated by computed tomography (CT) chest with contrast before EBUS examination. Enlarged mediastinal or hilar lymph node was defined as >1 cm short axis on the enhanced CT. Among the 52 patients studied, 57.7% were presented with mediastinal or hilar lymphadenopathy for diagnosis and 42.3% presented with suspected mediastinal malignancy. Paratracheal stations were the most common site for puncture in 33 lymph nodes (43%). The best diagnostic yield was obtained from subcarinal stations and the lowest yield from the hilar stations. Surgical biopsies confirmed lymphoma in six patients, tuberculosis (TB) in three, sarcoidosis in two and one had metastatic adenocarcinoma of unknown primary. The sensitivity, specificity, positive predictive value, and negative predictive value of EBUS-TBNA for diagnosis of mediastinal and hilar lymph node abnormalities were 78.6%, 100%, 100%, and 80%, respectively. The diagnostic yield of EBUS-TBNA in malignant and benign conditions was 79.0%. EBUS-TBNA is a safe and efficacious procedure which can be performed using conscious sedation with high yields. It can be used for the staging of malignancies as well as for the diagnosis of inflammatory and infectious conditions such as sarcoidosis and TB.

  3. Efficacy and adequacy of conventional transbronchial needle aspiration of IASLC stations 4R, 4L and 7 using endobronchial landmarks provided by the Wang nodal mapping system in the staging of lung cancer.

    PubMed

    Liu, Qinghua; Han, Songyan; Arias, Sixto; Turner, J Francis; Lee, Hans; Browning, Robert; Wang, Ko-Pen

    2016-01-01

    The role of transbronchial needle aspiration (TBNA) in the diagnosis and staging of lung cancer has been well established. Recently, the efficacy of conventional TBNA in the staging of lung cancer has been enhanced by the use of endobronchial ultrasound (EBUS)-TBNA. Our study sought to evaluate the adequacy of TBNA of International Association for the Study of Lung Cancer (IASLC) stations 4R, 4L and 7 using endobronchial landmarks provided by the Wang nodal mapping system in the staging of lung cancer. We retrospectively analyzed all bronchoscopic cases with conventional TBNA punctures positive for malignancy at our institution from 1 January to 31 October 2014. The endobronchial puncture site was guided by the Wang nodal mapping system. The Wang stations were correlated with the IASLC lymph node map. No endobronchial ultrasound or rapid on-site evaluation was used. Pathological analysis included cytological and histological examination. Diagnosis by histological analysis was obtained in 115 (55.3%) out of 208 puncture sites. The metastatic lymph nodes were distributed at IASLC stations 4R (W1, 3, 5) 46.6 %, 7 (W2, 8, 10) 19.7%, 4L (W4, 6) 11.5%, 11R (W7, W9) 11.1% 11L (W11) 9.6%, 2R (high station W3) 0.5%, and the proximal portion of station 8 (station W10 beyond the middle lobe orifice) 1%. No complications were observed. IASLC station 4R (W1, 3, 5), 7 (W2, 8, 10) and 4L (W4, 6) are adequate for the staging of lung cancer.

  4. Triple Gene Analysis Using Samples Obtained by Endobronchial Ultrasound-guided Transbronchial Needle Aspiration

    PubMed Central

    Lee, Kyungjong; Um, Sang-Won; Jeong, Byeong-Ho; Yang, Jung Wook; Choi, Yoon-La; Han, Joungho; Kim, Hojoong; Kwon, O Jung

    2016-01-01

    Objective A mutational analysis of tumor tissue samples is an important part of advanced lung cancer treatment strategies. This study evaluated the efficacy of a triple gene analysis using samples obtained via endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Methods Either metastatic lymph nodes or primary lung mass samples obtained by EBUS-TBNA were collected between May 2011 and May 2013. We consecutively analyzed epidermal growth factor receptor (EGFR), V-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS), and anaplastic lymphoma kinase (ALK) fusion genes using remnant tissue samples. Results A total of 109 patients were diagnosed with non-small cell lung cancer (NSCLC). Of these, 70% were adenocarcinoma, 27% squamous cell carcinoma with NSCLC, and 3% were related to other types of lung cancer. EGFR mutations were detected in 23 cases (21.1%), KRAS mutations in 13 cases (11.9%), and ALK fusion genes in 5 cases (4.9%). The ALK fusion genes could not be analyzed in four cases because of insufficient tissue samples remaining after routine histochemistry and an EGFR/KRAS mutation analysis. We found that small biopsy samples from EBUS-TBNA were adequate for performing a triple gene analysis in 97 patients (96%). ALK fusion protein immunohistochemistry (IHC) was 100% consistent with fluorescence in situ hybridization (FISH). Conclusion Small samples obtained by EBUS-TBNA were found to be sufficient for performing a triple gene analysis following routine histology and IHC. ALK IHC showed a very good concordance with FISH for detecting ALK fusion genes. PMID:27803402

  5. Value of different bronchoscopic sampling techniques in diagnosis of sarcoidosis: a prospective study of 151 patients.

    PubMed

    Goyal, Abhishek; Gupta, Dheeraj; Agarwal, Ritesh; Bal, Amanjit; Nijhawan, Raje; Aggarwal, Ashutosh N

    2014-07-01

    The exact position of routine bronchoscopic sampling techniques in diagnostic workup of sarcoidosis is often debated. Herein, we ascertain the role of transbronchial needle aspiration (TBNA), endobronchial ultrasound-guided TBNA (EBUS-TBNA), transbronchial lung biopsy (TBLB), and endobronchial biopsy (EBB) in diagnosis of sarcoidosis. Consecutive patients with suspected sarcoidosis who underwent fiberoptic bronchoscopy were studied. TBLB, EBB, TBNA, or EBUS-TBNA was performed as indicated in a standardized manner. A diagnosis of sarcoidosis was established based on the finding of non-necrotizing granulomas or on clinical grounds at 6-month follow-up. Individual and cumulative yield of various procedures and their correlation with clinicoradiologic parameters was analyzed. Of the 164 patients studied, 151 were finally diagnosed as sarcoidosis. Granulomas were demonstrated in 127 (84.2%) patients. Diagnostic yield of TBLB, EBB, TBNA, and EBUS-TBNA was 68.7%, 49.6%, 22.43%, and 57.1%, respectively. Cumulative yields of various procedures were: EBB+TBLB 81.4%; TBLB+TBNA 73.7%; TBNA+EBB 62.9%; TBLB+EBB+TBNA 86.9%; and TBLB+EBB+EBUS-TBNA 86.4%. In those with visible mucosal abnormalities, TBLB+EBB conferred the highest diagnostic yield (92.8%). Clinical findings or radiologic stage had no impact on diagnostic yield. TBLB is an important tool in bronchoscopic diagnosis of sarcoidosis. If endobronchial abnormalities are seen during bronchoscopy, TBLB with EBB gives the best results otherwise TBLB combined with conventional TBNA and EBB or EBUS-TBNA are required to maximize the diagnostic yield.

  6. Complications, Consequences, and Practice Patterns of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    Shah, Archan M.; Lei, Xiudong; Jimenez, Carlos A.; Morice, Rodolfo C.; Yarmus, Lonny; Filner, Joshua; Ray, Cynthia; Michaud, Gaetane; Greenhill, Sara R.; Sarkiss, Mona; Casal, Roberto; Rice, David; Ost, David E.

    2013-01-01

    Background: Few studies of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) have been large enough to identify risk factors for complications. The primary objective of this study was to quantify the incidence of and risk factors for complications in patients undergoing EBUS-TBNA. Methods: Data on prospectively enrolled patients undergoing EBUS-TBNA in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) database were extracted and analyzed for the incidence, consequences, and predictors of complications. Results: We enrolled 1,317 patients at six hospitals. Complications occurred in 19 patients (1.44%; 95% CI, 0.87%-2.24%). Transbronchial lung biopsy (TBBx) was the only risk factor for complications, which occurred in 3.21% of patients who underwent the procedure and in 1.15% of those who did not (OR, 2.85; 95% CI, 1.07-7.59; P = .04). Pneumothorax occurred in seven patients (0.53%; 95% CI, 0.21%-1.09%). Escalations in level of care occurred in 14 patients (1.06%; 95% CI, 0.58%-1.78%); its risk factors were age > 70 years (OR, 4.06; 95% CI, 1.36-12.12; P = .012), inpatient status (OR, 4.93; 95% CI, 1.30-18.74; P = .019), and undergoing deep sedation or general anesthesia (OR, 4.68; 95% CI, 1.02-21.61; P = .048). TBBx was performed in only 12.6% of patients when rapid onsite cytologic evaluation (ROSE) was used and in 19.1% when it was not used (P = .006). Interhospital variation in TBBx use when ROSE was used was significant (P < .001). Conclusions: TBBx was the only risk factor for complications during EBUS-TBNA procedures. ROSE significantly reduced the use of TBBx. PMID:23117878

  7. Electromagnetic navigation-guided TBNA vs conventional TBNA in the diagnosis of mediastinal lymphadenopathy.

    PubMed

    Diken, Özlem E; Karnak, Demet; Çiledağ, Aydın; Ceyhan, Koray; Atasoy, Çetin; Akyar, Serdar; Kayacan, Oya

    2015-04-01

    Conventional transbronchial needle aspiration (C-TBNA) is a safe method for the diagnosis of hilar and mediastinal lymphadenopathy (MLN). However, diagnostic yield of this technique varies considerably. Electromagnetic navigation bronchoscopy (ENB) is a new technology to increase the diagnostic yield of flexible bronchoscopy for the peripheral lung lesions and MLN. The aim of this prospective study was to compare the diagnostic and sampling success of ENB-guided TBNA (ENB-TBNA) in comparison with C-TBNA while dealing with MLN. Consecutive patients with MLN were randomized into two groups - C-TBNA and ENB-TBNA - using a computer-based number shuffling system to avoid recruitment bias. Procedures were performed in usual fashion, published previously. Ninety-four cases (M/F: 45/49) with a total of 145 stations of MLN were enrolled in the study. In 44 patients, 81 stations were sampled by ENB-TBNA, and in 50 patients 64 stations by C-TBNA. The mean size of MLN in study subjects was 17.56 ± 6.25 mm. The sampling success was significantly higher in ENB-TBNA group (82.7%) compared with C-TBNA group (51.6%) (P < 0.005). Defined by histopathological result, the diagnostic yield in ENB-TBNA was 72.8%, and 42.2% with C-TBNA (P < 0.005). For subcarinal localization, sampling or diagnostic success was higher in ENB-TBNA than that of C-TBNA (P < 0.05). Based on the size of the MLN ≤15 mm or >15 mm, the sampling success of ENB-TBNA was also significantly higher than C-TBNA in both subgroups (P < 0.005 and P < 0.005, respectively). No serious complication was observed. In this study comparing ENB-TBNA and C-TBNA, the sampling and diagnostic success of ENB-TBNA was found to be superior while dealing with MLN, in all categories studied. © 2014 John Wiley & Sons Ltd.

  8. A mass that has no (EBUS) echo.

    PubMed

    Rosenblum, Matthew K; Wang, Sue X; Seeley, Eric J

    2018-01-01

    We report findings for a patient that underwent endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA) for diagnostic purposes after an abnormal chest CT. The patient initially presented with cough and shortness of breath. Chest CT revealed a 6 cm soft tissue mass with mildly enlarged right hilar lymph nodes (LNs) and a small right sided pleural effusion. Based on these radiologic findings, the patient underwent an EBUS guided FNA of the mass. To our surprise, the mass was hypoechoic by EBUS and on aspiration, the syringe filled with yellow fluid. This finding in combination with a re-review of the CT scans with a special focus on the Hounsfield Units of the lesion confirmed the diagnosis of a mediastinal bronchogenic cyst. This case demonstrates the role of Hounsfield units in analyzing mediastinal masses and highlights the effectiveness of EBUS guided TBNA in diagnosis and treatment of bronchogenic cysts.

  9. Effectiveness of the Benign and Malignant Diagnosis of Mediastinal and Hilar Lymph Nodes by Endobronchial Ultrasound Elastography.

    PubMed

    Huang, Haidong; Huang, Zhiang; Wang, Qin; Wang, Xinan; Dong, Yuchao; Zhang, Wei; Zarogoulidis, Paul; Man, Yan-Gao; Schmidt, Wolfgang Hohenforst; Bai, Chong

    2017-01-01

    Background and Objectives: Endobronchial ultrasound elastography is a new technique for describing the stiffness of tissue during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aims of this study were to investigate the diagnostic value of Endobronchial ultrasound (EBUS) elastography for distinguishing the difference between benign and malignant lymph nodes among mediastinal and hilar lymph node. Materials and Methods: From June 2015 to August 2015, 47 patients confirmed of mediastinal and hilar lymph node enlargement through examination of Computed tomography (CT) were enrolled, and a total of 78 lymph nodes were evaluated by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). EBUS-guided elastography of lymph nodes was performed prior to EBUS-TBNA. A convex probe EBUS was used with a new EBUS processor to assess elastographic patterns that were classified based on color distribution as follows: Type 1, predominantly non-blue (green, yellow and red); Type 2, part blue, part non-blue (green, yellow and red); Type 3, predominantly blue. Pathological determination of malignant or benign lymph nodes was used as the gold standard for this study. The elastographic patterns were compared with the final pathologic results from EBUS-TBNA. Results: On pathological evaluation of the lymph nodes, 45 were benign and 33 were malignant. The lymph nodes that were classified as Type 1 on endobronchial ultrasound elastography were benign in 26/27 (96.3%) and malignant in 1/27 (3.7%); for Type 2 lymph nodes, 15/20 (75.0%) were benign and 5/20 (25.0%) were malignant; Type 3 lymph nodes were benign in 4/31 (12.9%) and malignant in 27/31 (87.1%). In classifying Type 1 as 'benign' and Type 3 as 'malignant,' the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rates were 96.43%, 86.67%, 87.10%, 96.30%, 91.38%, respectively. Conclusion: EBUS elastography of mediastinal and hilar lymph nodes is a noninvasive technique that can be performed reliably and may be helpful in the prediction of benign and malignant lymph nodes among mediastinal and hilar lymph node during EBUS-TBNA.

  10. Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules.

    PubMed

    Arias, Sixto; Lee, Hans; Semaan, Roy; Frimpong, Bernice; Ortiz, Ricardo; Feller-Kopman, David; Oakjones-Burgess, Karen; Yarmus, Lonny

    2015-05-23

    Lung nodule evaluation represents a clinical challenge especially in patients with intermediate risk for malignancy. Multiple technologies are presently available to sample nodules for pathological diagnosis. Those technologies can be divided into bronchoscopic and non-bronchoscopic interventions. Electromagnetic navigational bronchoscopy is being extensively used for the endobronchial approach to peripheral lung nodules but has been hindered by anatomic challenges resulting in a 70% diagnostic yield. Electromagnetic navigational guided transthoracic needle lung biopsy is novel non-bronchoscopic method that uses a percutaneous electromagnetic tip tracked needle to obtain core biopsy specimens. Electromagnetic navigational transthoracic needle aspiration complements bronchoscopic techniques potentially allowing the provider to maximize the diagnostic yield during one single procedure. This article describes a novel integrated diagnostic approach to pulmonary lung nodules. We propose the use of endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging; radial EBUS, navigational bronchoscopy and E-TTNA during one single procedure to maximize diagnostic yield and minimize the number of invasive procedures needed to obtain a diagnosis. This manuscript describes in detail how the navigation transthoracic procedure is performed. Additional clinical studies are needed to determine the clinical utility of this novel technology.

  11. The value of rapid on-site evaluation during EBUS-TBNA.

    PubMed

    Cardoso, A V; Neves, I; Magalhães, A; Sucena, M; Barroca, H; Fernandes, G

    2015-01-01

    Rapid on-site evaluation (ROSE) has the potential to increase endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) accuracy in the diagnosis of mediastinal lesions and lung cancer staging. However, studies have reported controversial results. The purpose of our study was to evaluate the influence of ROSE on sample adequacy and diagnostic accuracy of EBUS-TBNA. Prospective observational study that enrolled 81 patients who underwent EBUS-TBNA for investigation of hilo-mediastinal lesions or lung cancer staging. The first 41 patients underwent EBUS-TBNA with ROSE (ROSE group) and the last 40 patients without ROSE (non-ROSE group). Sample adequacy and diagnostic accuracy of EBUS-TBNA in both groups were compared. Adequate samples were obtained in 93% of the patients in the ROSE group and 80% in non-ROSE group (p=0.10). The diagnostic accuracy of EBUS-TBNA was 91% in ROSE group and 83% in non-ROSE group (p=0.08). Analyzing the EBUS-TBNA purpose, in the subgroup of patients who underwent EBUS-TBNA for investigation of hilo-mediastinal lesions, these differences between ROSE and non-ROSE group were higher compared to lung cancer staging, 93% of patients with adequate samples in the ROSE group vs. 75% in the non-ROSE group (p=0.06) and 87% of diagnostic accuracy in ROSE group vs. 77% in non-ROSE group (p=0.10). Despite the lack of statistical significance, ROSE appears to be particularly useful in the diagnostic work-up of hilo-mediastinal lesions, increasing the diagnostic yield of EBUS-TBNA. Copyright © 2014 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L.U. All rights reserved.

  12. Endobronchial ultrasonography versus mediastinoscopy: a single-institution cost analysis and waste comparison.

    PubMed

    Andrade, Rafael S; Podgaetz, Eitan; Rueth, Natasha M; Majumder, Kaustav; Hall, Eric; Saric, Crystal; Thelen, Lynn

    2014-09-01

    Mediastinoscopy (MED) and endobronchial ultrasonography with transbronchial needle aspiration (EBUS-TBNA) have similar accuracy for mediastinal lymph node sampling (MLNS). The threatened financial and environmental sustainability of our health care system mandate that surgeons consider cost and environmental impact in clinical decision making of similarly effective procedures. We performed a cost and waste comparison of MED versus EBUS-TBNA for MLNS to raise awareness of the financial and environmental implications of our practices. We conducted a retrospective review of outpatients who underwent MLNS under general anesthesia in the OR with MED or EBUS-TBNA (September 2007 to December 2009). We analyzed direct costs based on hospital charges, calculated expected payment using a decision support model, and profit margins (modeled expected payment-direct costs). Our waste comparison was measured in kilograms of solid waste per case. We performed MLNS in 148 patients (89 EBUS-TBNA, 39 MED, 20 EBUS + MED). Direct costs were lower for MED ($2,356) compared with EBUS-TBNA ($2,503), whereas expected payment was greater (MED, $3,449; EBUS-TBNA, $3,249), resulting in a profit margin that was $347 greater for MED. The amount of solid waste for each MED was 1.8 kg versus 0.5 kg for EBUS-TBNA. MED costs less than EBUS-TBNA in the OR setting but generates 3.6 times the amount of EBUS-TBNA waste. The cost of EBUS-TBNA may improve by performance in the endoscopy suite, and surgical pack revision could reduce the amount of MED solid waste. This comparison sets the stage for sophistication of our clinical decision making, taking into consideration the major threats to our health care system. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    2011-01-01

    Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further investigate other determinants of diagnostic yield. PMID:21659432

  14. Usefulness of conventional transbronchial needle aspiration in the diagnosis, staging and molecular characterization of pulmonary neoplasias by thin-prep based cytology: experience of a single oncological institute.

    PubMed

    Ramieri, Maria Teresa; Marandino, Ferdinando; Visca, Paolo; Salvitti, Tommaso; Gallo, Enzo; Casini, Beatrice; Giordano, Francesca Romana; Frigieri, Claudia; Caterino, Mauro; Carlini, Sandro; Rinaldi, Massimo; Ceribelli, Anna; Pennetti, Annarita; Alò, Pier Luigi; Marino, Mirella; Pescarmona, Edoardo; Filippetti, Massimo

    2016-08-01

    Conventional transbronchial needle aspiration (c-TBNA) contributed to improve the bronchoscopic examination, allowing to sample lesions located even outside the tracheo-bronchial tree and in the hilo-mediastinal district, both for diagnostic and staging purposes. We have evaluated the sensitivity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of the c-TBNA performed during the 2005-2015 period for suspicious lung neoplasia and/or hilar and mediastinal lymphadenopathy at the Thoracic endoscopy of the Thoracic Surgery Department of the Regina Elena National Cancer Institute, Rome. Data from 273 consecutive patients (205 males and 68 females) were analyzed. Among 158 (58%) adequate specimens, 112 (41%) were neoplastic or contained atypical cells, 46 (17%) were negative or not diagnostic. We considered in the analysis first the overall period; then we compared the findings of the first [2005-2011] and second period [2012-2015] and, finally, only those of adequate specimens. During the overall period, sensibility and accuracy values were respectively of 53% and 63%, in the first period they reached 41% and 53% respectively; in the second period sensibility and accuracy reached 60% and 68%. Considering only the adequate specimens, sensibility and accuracy during the overall period were respectively of 80% and 82%; the values obtained for the first period were 68% and 72%. Finally, in the second period, sensibility reached 86% and accuracy 89%. Carcinoma-subtyping was possible in 112 cases, adenocarcinomas being diagnosed in 50 cases; further, in 30 cases molecular predictive data could be obtained. The c-TBNA proved to be an efficient method for the diagnosis/staging of lung neoplasms and for the diagnosis of mediastinal lymphadenopathy. Endoscopist's skill and technical development, associated to thin-prep cytology and to a rapid on site examination (ROSE), were able to provide by c-TBNA a high diagnostic yield and molecular predictive data in advanced lung carcinomas.

  15. Diagnostic performance of convex probe EBUS-TBNA in patients with mediastinal and coexistent endobronchial or peripheral lesions

    PubMed Central

    Verma, Akash; Goh, Kee San; Phua, Chee Kiang; Sim, Wen Yuan; Tee, Kuan Sen; Lim, Albert Y.H.; Tai, Dessmon Y.H.; Goh, Soon Keng; Kor, Ai Ching; Ho, Benjamin; Lew, Sennen J.W.; Abisheganaden, John

    2016-01-01

    Abstract To compare the performance of convex probe endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) with conventional endobronchial biopsy (EBB) or transbronchial lung biopsy (TBLB) in patients with mediastinal, and coexisting endobronchial or peripheral lesions. Retrospective review of records of patients undergoing diagnostic EBUS-TBNA and conventional bronchoscopy in 2014. A total of 74 patients had mediastinal, and coexisting endobronchial or peripheral lesions. The detection rate of EBUS-TBNA for mediastinal lesion >1 cm in short axis, EBB for visible exophytic type of endobronchial lesion, and TBLB for peripheral lesion with bronchus sign were 71%, 75%, and 86%, respectively. In contrast, the detection rate of EBUS-TBNA for mediastinal lesion ≤1 cm in short axis, EBB for mucosal hyperemia type of endobronchial lesion, and TBLB for peripheral lesion without bronchus sign were 25%, 63%, and 38%, and improved to 63%, 88%, and 62% respectively by adding EBB or TBLB to EBUS-TBNA, and EBUS-TBNA to EBB or TBLB. Postprocedure bleeding was significantly more common in patients undergoing EBB and TBLB 8 (40%) versus convex probe EBUS-TBNA 2 patients (2.7%, P = 0.0004). EBUS-TBNA is a safer single diagnostic technique compared with EBB or TBLB in patients with mediastinal lesion of >1 cm in size, and coexisting exophytic type of endobronchial lesion, or peripheral lesion with bronchus sign. However, it requires combining with EBB or TBLB and vice versa to optimize yield when mediastinal lesion is ≤1 cm in size, and coexisting endobronchial and peripheral lesions lack exophytic nature, and bronchus sign, respectively. PMID:27977603

  16. Implementing Endobronchial Ultrasound-Guided (EBUS) for Staging and Diagnosis of Lung Cancer: A Cost Analysis

    PubMed Central

    Slavova-Azmanova, Neli S.; Phillips, Martin; Trevenen, Michelle L.; Li, Ian W.; Johnson, Claire E.

    2018-01-01

    Background Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and guide sheath (EBUS-GS) are gaining popularity for diagnosis and staging of lung cancer compared to CT-guided transthoracic needle aspiration (CT-TTNA), blind fiber-optic bronchoscopy, and mediastinoscopy. This paper aimed to examine predictors of higher costs for diagnosing and staging lung cancer, and to assess the effect of EBUS techniques on hospital cost. Material/Methods Hospital costs for diagnosis and staging of new primary lung cancer patients presenting in 2007–2008 and 2010–2011 were reviewed retrospectively. Multiple linear regression was used to determine relationships with hospital cost. Results We reviewed 560 lung cancer patient records; 100 EBUS procedures were performed on 90 patients. Higher hospital costs were associated with: EBUS-TBNA performed (p<0.0001); increasing inpatient length of stay (p<0.0001); increasing number of other surgical/diagnostic procedures (p<0.0001); whether the date of management decision fell within an inpatient visit (p<0.0001); and if the patient did not have a CT-TTNA, then costs increased as the number of imaging events increased (interaction p<0.0001). Cohort was not significantly related to cost. Location of the procedure (outside vs. inside theater) was a predictor of lower one-day EBUS costs (p<0.0001). Cost modelling revealed potential cost saving of $1506 per EBUS patient if all EBUS procedures were performed outside rather than in the theater ($66,259 per annum). Conclusions EBUS-TBNA only was an independent predictor of higher cost for diagnosis and staging of lung cancer. Performing EBUS outside compared to in the theater may lower costs for one-day procedures; potential future savings are considerable if more EBUS procedures could be performed outside the operating theater. PMID:29377878

  17. Randomized Trial of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration With and Without Rapid On-site Evaluation for Lung Cancer Genotyping.

    PubMed

    Trisolini, Rocco; Cancellieri, Alessandra; Tinelli, Carmine; de Biase, Dario; Valentini, Ilaria; Casadei, Gianpiero; Paioli, Daniela; Ferrari, Franco; Gordini, Giovanni; Patelli, Marco; Tallini, Giovanni

    2015-12-01

    Experts and scientific society guidelines recommend that rapid on-site evaluation (ROSE) be used with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) to optimize lung cancer genotyping, but no comparative trial has been carried out to confirm and quantify its usefulness. To assess the influence of ROSE on the yield of EBUS-TBNA for a multigene molecular analysis of lung cancer samples, consecutive patients with suspected or known advanced lung cancer were randomized to undergo EBUS-TBNA without ROSE (EBUS arm) or with ROSE (ROSE arm). The primary end point was the rate of the successful accomplishment of the institution's clinical protocol for molecular profiling of nonsquamous non-small cell lung cancer (EGFR and KRAS testing, followed by ALK testing for tumors with EGFR and KRAS wild-type status). Complete genotyping was achieved in 108 of 126 patients (85.7%) (90.8% in the ROSE arm vs 80.3% in the EBUS arm, P = .09). The patients in the ROSE arm were less likely to have samples that could be used only for pathologic diagnosis because of minimal tumor burden (0 vs 6, P = .05), and were more likely to have the bronchoscopy terminated after a single biopsy site (58.9% vs 44.1%, P = .01). ROSE prevents the need for a repeat invasive diagnostic procedure aimed at molecular profiling in at least one out of 10 patients with advanced lung cancer and significantly reduces the risk of retrieving samples that can be used only for pathologic subtyping because of minimal tumor burden. ClinicalTrials.gov; No.: NCT01799382; URL: www.clinicaltrials.gov.

  18. Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.

    PubMed

    Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R

    2012-02-01

    One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.

  19. Systematic Compared With Targeted Staging with Endobronchial Ultrasound in Patients with Lung Cancer.

    PubMed

    Sanz-Santos, José; Serra, Pere; Torky, Mohamed; Andreo, Felipe; Centeno, Carmen; Mendiluce, Leire; Martínez-Barenys, Carlos; López de Castro, Pedro; Ruiz-Manzano, Juan

    2018-04-06

    To evaluate the accuracy of systematic mediastinal staging by endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) (sampling of all visible nodes measuring ≥5mm from stations N3 to N1 regardless of their positron emission tomography/computed tomography (PET/CT) features) and compare this staging approach with targeted EBUS-TBNA staging (sampling only 18F-fluorodeoxyglucose (FDG)-avid nodes) in patients with N2 non-small cell lung cancer (NSCLC) on PET/CT. Retrospective study of 107 patients who underwent systematic EBUS-TBNA mediastinal staging. The results were compared with those of a hypothetical scenario where only FDG-avid nodes on PET/CT would be sampled. Systematic EBUS-TBNA sampling demonstrated N3 disease in 3 patients, N2 disease in 60 (42 single-station or N2a, 18 multiple-station or N2b) and N0/N1 disease in 44. Of these 44, seven underwent mediastinoscopy, which did not show mediastinal disease; six of the seven proceeded to lung resection, which also showed no mediastinal disease. Thirty-four N0/N1 patients after EBUS-TBNA underwent lung resection directly: N0/N1 was found in 30 and N2 in four (one N2b with a PET/CT showing N2a disease, three N2a). Sensitivity, specificity, negative predictive value, positive predictive value, and overall accuracy of systematic EBUS-TBNA were 94%, 100%, 90%, 100% and 96%, respectively. Compared to targeted EBUS-TBNA, systematic EBUS-TBNA sampling provided additional important clinical information in 14 cases (13%): three N3 cases would have passed unnoticed, and 11 N2b cases would have been staged as N2a. In clinical practice, systematic sampling of the mediastinum by EBUS-TBNA, regardless of PET/CT features, is to be recommended over targeted sampling. Copyright © 2018. Published by Elsevier Inc.

  20. A novel platform for electromagnetic navigated ultrasound bronchoscopy (EBUS).

    PubMed

    Sorger, Hanne; Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Leira, Håkon Olav

    2016-08-01

    Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) of mediastinal lymph nodes is essential for lung cancer staging and distinction between curative and palliative treatment. Precise sampling is crucial. Navigation and multimodal imaging may improve the efficiency of EBUS-TBNA. We demonstrate a novel EBUS-TBNA navigation system in a dedicated airway phantom. Using a convex probe EBUS bronchoscope (CP-EBUS) with an integrated sensor for electromagnetic (EM) position tracking, we performed navigated CP-EBUS in a phantom. Preoperative computed tomography (CT) and real-time ultrasound (US) images were integrated into a navigation platform for EM navigated bronchoscopy. The coordinates of targets in CT and US volumes were registered in the navigation system, and the position deviation was calculated. The system visualized all tumor models and displayed their fused CT and US images in correct positions in the navigation system. Navigating the EBUS bronchoscope was fast and easy. Mean error observed between US and CT positions for 11 target lesions (37 measurements) was [Formula: see text] mm, maximum error was 5.9 mm. The feasibility of our novel navigated CP-EBUS system was successfully demonstrated. An EBUS navigation system is needed to meet future requirements of precise mediastinal lymph node mapping, and provides new opportunities for procedure documentation in EBUS-TBNA.

  1. The contribution of cell blocks in the diagnosis of mediastinal masses and hilar adenopathy samples from echobronchoscopy.

    PubMed

    Lourido-Cebreiro, Tamara; Leiro-Fernández, Virginia; Tardio-Baiges, Antoni; Botana-Rial, Maribel; Núñez-Delgado, Manuel; Álvarez-Martín, M Jesús; Fernández-Villar, Alberto

    2014-07-01

    Cell block material from puncture can be obtained with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in many cases. The aim of this study was to analyse the value of additional information from cell blocks obtained with EBUS-TBNA samples from mediastinal and hilar lymph nodes and masses. Review of pathology reports with a specific diagnosis obtained from EBUS-TBNA samples of mediastinal or hilar lesions, prospectively obtained over a two-year period. The generation of cell blocks from cytology needle samples, the contribution to morphological diagnosis, and the possible use of samples for immunohistochemistry were analysed. One hundred and twenty-nine samples corresponding to 110 patients were reviewed. The diagnosis was lung cancer in 81% of cases, extrapulmonary carcinoma in 10%, sarcoidosis in 4%, lymphoma in 2.7%, and tuberculosis in 0.9%. Cell blocks could be obtained in 72% of cases. Immunohistochemistry studies on the cell blocks were significantly easier to perform than on conventional smears (52.6% vs. 14%, P<.0001). In 4cases, the cell block provided an exclusive morphological diagnosis (3sarcoidosis and one metastasis from prostatic carcinoma) and in 3carcinomas, subtype and origin could be identified. Exclusive diagnoses from the cell block were significantly more frequent in benign disease than in malignant disease (25% vs 0.9%, P=.002). Cell blocks were obtained from 72% of EBUS-TBNA diagnostic procedures. The main contributions of cell blocks to pathology examinations were the possibility of carrying out immunohistochemical staining for the better classification of neoplasms, especially extrapulmonary metastatic tumours, and the improved diagnosis of benign lesions. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  2. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  3. Comparison of Epidermal Growth Factor Receptor Mutations between Metastatic Lymph Node Diagnosed by EBUS-TBNA and Primary Tumor in Non-Small Cell Lung Cancer

    PubMed Central

    Kang, Hyo Jae; Hwangbo, Bin; Lee, Jin Soo; Kim, Moon Soo; Lee, Jong Mog; Lee, Geon-Kook

    2016-01-01

    Introduction Although the use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is increasing for epidermal growth factor receptor (EGFR) testing in lung cancer, the discordance rate in EGFR mutations between lymph node (LN) samples obtained by EBUS-TBNA and primary tumor (PT) is not well known. Thus, we compared the EGFR mutation status of LN samples obtained by EBUS-TBNA and PTs to estimate the efficacy of using EBUS-TBNA specimens for EGFR testing in advanced, non-squamous, non-small cell lung cancer (NSCLC). Materials and Methods Using data of patients from the EBUS-TBNA database (N = 1914) obtained between January 2009 and January 2013, we identified 100 treatment-naïve, advanced, non-squamous NSCLC patients (stage 3 and 4) with matched LN specimens obtained by EBUS-TBNA and PT specimens. Of these, 74 patients with paired specimens were feasible for EGFR mutation analysis, which we performed using a direct sequencing method. Results Of the 74 cases, at least one major [exon 19 deleted (19del) and L858R] or minor (T790M, exon 20 insertion, and other point mutations) EGFR mutation was detected in 31 cases (41.9%), which included PT (n = 31, 41.9%) and LN (n = 28, 37.8%) specimens. Major mutations were detected in 25 PT (33.8%, 19del = 13, L858R = 12) and 22 LN (29.8%, 19del = 11, L858R = 11) specimens. The discordance rate in major mutations between matched PT and LN specimens was 4.1% (3/74). Among minor mutations, T790M was detected in LN specimen only in 2 cases with L858R in PT and LN. The discordance rate major and minor EGFR mutations combined between matched PT and LN specimens was 12% (9/74). Conclusions We observed a high concordance rate of major EGFR mutations between matched LN specimens sampled by EBUS-TBNA and PTs, suggesting that LN samples obtained by EBUS-TBNA from advanced non-squamous NSCLC patients are effective for use in EGFR mutation testing. PMID:27685950

  4. EBUS-TBNA Provides Highest RNA Yield for Multiple Biomarker Testing from Routinely Obtained Small Biopsies in Non-Small Cell Lung Cancer Patients - A Comparative Study of Three Different Minimal Invasive Sampling Methods

    PubMed Central

    Schmid-Bindert, Gerald; Wang, Yongsheng; Jiang, Hongbin; Sun, Hui; Henzler, Thomas; Wang, Hao; Pilz, Lothar R.; Ren, Shengxiang; Zhou, Caicun

    2013-01-01

    Background Multiple biomarker testing is necessary to facilitate individualized treatment of lung cancer patients. More than 80% of lung cancers are diagnosed based on very small tumor samples. Often there is not enough tissue for molecular analysis. We compared three minimal invasive sampling methods with respect to RNA quantity for molecular testing. Methods 106 small biopsies were prospectively collected by three different methods forceps biopsy, endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA), and CT-guided core biopsy. Samples were split into two halves. One part was formalin fixed and paraffin embedded for standard pathological evaluation. The other part was put in RNAlater for immediate RNA/DNA extraction. If the pathologist confirmed the diagnosis of non-small cell lung cancer(NSCLC), the following molecular markers were tested: EGFR mutation, ERCC1, RRM1 and BRCA1. Results Overall, RNA-extraction was possible in 101 out of 106 patients (95.3%). We found 49% adenocarcinomas, 38% squamouscarcinomas, and 14% non-otherwise-specified(NOS). The highest RNA yield came from endobronchial ultrasound guided needle aspiration, which was significantly higher than bronchoscopy (37.74±41.09 vs. 13.74±15.53 ng respectively, P = 0.005) and numerically higher than CT-core biopsy (37.74±41.09 vs. 28.72±44.27 ng respectively, P = 0.244). EGFR mutation testing was feasible in 100% of evaluable patients and its incidence was 40.8%, 7.9% and 14.3% in adenocarcinomas, squamouscarcinomas and NSCLC NOS subgroup respectively. There was no difference in the feasibility of molecular testing between the three sampling methods with feasibility rates for ERCC1, RRM1 and BRCA1 of 91%, 87% and 81% respectively. Conclusion All three methods can provide sufficient tumor material for multiple biomarkers testing from routinely obtained small biopsies in lung cancer patients. In our study EBUS guided needle aspiration provided the highest amount of tumor RNA compared to bronchoscopy or CT guided core biopsy. Thus EBUS should be considered as an acceptable option for tissue acquisition for molecular testing. PMID:24205040

  5. Videothoracoscopy in the treatment of mediastinal cysts

    PubMed Central

    Brzeziński, Daniel; Kozak, Józef

    2014-01-01

    Introduction Progress in the development of surgical techniques has led to the growing use of video-assisted thoracoscopic surgery (VATS) techniques in mediastinal cyst treatment. Aim To present our experience of treating mediastinal cysts with the minimally invasive technique. Material and methods Fifty patients with mediastinal cysts were treated from 2001 to 2011. There were 32 women and 18 men. The age of the patients ranged from 17 to 72, the mean age being 42 years. All patients underwent basic preoperative diagnostic tests of the chest: X-ray, computed tomography (CT), bronchoscopy and spirometry; 4 patients underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and 3 fine needle aspiration biopsy (FNAB) of the described lesions. Results The VATS was performed in each case. Conversion was carried out due to superior mediastinal location in 10 cases and pleural adhesions in 3 cases. The partial resection of a cyst was performed in 3 patients. One patient was treated conservatively due to heart failure. In that patient the transthoracic needle aspiration of a cyst under ultrasound guidance using alcoholisation with 76% ethanol with a good effect was performed twice. Cyst recurrence was observed in 1 case. Conclusions The surgical access depends on the location of a cyst. The VATS resection of a superior mediastinal cyst is not always feasible. Surgery of mediastinal cysts is both diagnostic and curative. PMID:25337163

  6. Endobronchial Ultrasound in Suspected Non-Malignant Mediastinal Lymphadenopathy.

    PubMed

    Eickhoff, L; Golpon, H; Zardo, P; Suhling, H; Welte, T; Jonigk, D; Gottlieb, J; Fuehner, T

    2018-05-22

     Endobronchial ultrasound (EBUS) bronchoscopy with transbronchial needle aspiration (TBNA) is a well-established tool in mediastinal staging in lung cancer and gains importance in exploration of non-malignant lymphadenopathy. The aim of this study was to evaluate the role of EBUS-TBNA in suspected non-malignant diseases.  A retrospective, single-center, observation analysis of endobronchial ultrasound bronchoscopy procedures was performed in a university medical center between March 2013 and July 2015. All patients with suspected non-malignant mediastinal lymphadenopathy were included. Cytopathological and microbiological results of EBUS were compared to clinical diagnosis 6 months after procedure and performance of EBUS was contrasted to malignant indications.  During study period, 333 EBUS bronchoscopies in 315 patients with mediastinal lymphadenopathy were performed. 111 out of 315 (35 %) patients had neither primary signs nor history of a malignant disease, categorised as patients with suspected non-malignant disease. 245 lymph nodes were sampled (median size 15 mm [IQR10 - 19]). Preferred station for TBNA was lymph node station 7 (38 %). Cytopathological findings revealed non-specific inflammation (n = 81; 70 %), carcinoma (n = 7; 6 %), epithelioid cell granulomas (n = 20; 17 %). 7 samples (6 %) were non-representative. Microbiologic testing of lymph nodes identified 3 infections (Mycobacteria tuberculosis [n = 2] and Nocardia nova [n = 1]) relevant to antibiotic therapy. Minor adverse events were observed in 9 out of 115 (8 %) patients. Sensitivity of EBUS-TBNA intervention in suspected non-malignant disease was 76 % and specificity 96 %.  EBUS-TBNA revealed a specific cause for suspected non-malignant lymphadenopathy in one-third of cases and was associated with excellent specificity. Predominant specific causes were granuloma, besides from tumor. In 3 patients pathogen could be isolated by TBNA. © Georg Thieme Verlag KG Stuttgart · New York.

  7. A survey of flexible bronchoscopy practices in India: The Indian bronchoscopy survey (2017)

    PubMed Central

    Madan, Karan; Mohan, Anant; Agarwal, Ritesh; Hadda, Vijay; Khilnani, Gopi C; Guleria, Randeep

    2018-01-01

    Background: There is a lack of contemporaneous data on the practices of flexible bronchoscopy in India. Aim: The aim of the study was to study the prevalent practices of flexible bronchoscopy across India. Methods: The “Indian Bronchoscopy Survey” was a 98-question, online survey structured into the following sections: general information, patient preparation and monitoring, sedation and topical anesthesia, procedural/technical aspects, and bronchoscope disinfection/staff protection. Results: Responses from 669 bronchoscopists (mean age: 40.2 years, 91.8% adult pulmonologists) were available for analysis. Approximately, 70,000 flexible bronchoscopy examinations had been performed over the preceding year. A majority (59%) of bronchoscopists were performing bronchoscopy without sedation. A large number (45%) of bronchoscopists had learned the procedure outside of their fellowship training. About 55% used anticholinergic premedication either as a routine or occasionally. Nebulized lignocaine was being used by 72%, while 24% utilized transtracheal administration of lignocaine. The most commonly (75%) used concentration of lignocaine was 2%. Midazolam with or without fentanyl was the preferred agent for intravenous sedation. The use of video bronchoscope was common (80.8%). The most common (94%) route for performing bronchoscopy was nasal. Conventional transbronchial needle aspiration (TBNA) was being performed by 74%, while 92% and 78% performed endobronchial and transbronchial lung biopsy, respectively. Therapeutic airway interventions (stents, electrocautery, cryotherapy, and others) were being performed by 30%, while endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) and rigid bronchoscopy were performed by 27% and 19.5%, respectively. Conclusion: There is a wide national variation in the practices of performing flexible bronchoscopy. However, there has been a considerable improvement in bronchoscopy practices compared to previous national surveys. PMID:29487243

  8. A survey of flexible bronchoscopy practices in India: The Indian bronchoscopy survey (2017).

    PubMed

    Madan, Karan; Mohan, Anant; Agarwal, Ritesh; Hadda, Vijay; Khilnani, Gopi C; Guleria, Randeep

    2018-01-01

    There is a lack of contemporaneous data on the practices of flexible bronchoscopy in India. The aim of the study was to study the prevalent practices of flexible bronchoscopy across India. The "Indian Bronchoscopy Survey" was a 98-question, online survey structured into the following sections: general information, patient preparation and monitoring, sedation and topical anesthesia, procedural/technical aspects, and bronchoscope disinfection/staff protection. Responses from 669 bronchoscopists (mean age: 40.2 years, 91.8% adult pulmonologists) were available for analysis. Approximately, 70,000 flexible bronchoscopy examinations had been performed over the preceding year. A majority (59%) of bronchoscopists were performing bronchoscopy without sedation. A large number (45%) of bronchoscopists had learned the procedure outside of their fellowship training. About 55% used anticholinergic premedication either as a routine or occasionally. Nebulized lignocaine was being used by 72%, while 24% utilized transtracheal administration of lignocaine. The most commonly (75%) used concentration of lignocaine was 2%. Midazolam with or without fentanyl was the preferred agent for intravenous sedation. The use of video bronchoscope was common (80.8%). The most common (94%) route for performing bronchoscopy was nasal. Conventional transbronchial needle aspiration (TBNA) was being performed by 74%, while 92% and 78% performed endobronchial and transbronchial lung biopsy, respectively. Therapeutic airway interventions (stents, electrocautery, cryotherapy, and others) were being performed by 30%, while endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) and rigid bronchoscopy were performed by 27% and 19.5%, respectively. There is a wide national variation in the practices of performing flexible bronchoscopy. However, there has been a considerable improvement in bronchoscopy practices compared to previous national surveys.

  9. Optimal sequence of tests for the mediastinal staging of non-small cell lung cancer.

    PubMed

    Luque, Manuel; Díez, Francisco Javier; Disdier, Carlos

    2016-01-26

    Non-small cell lung cancer (NSCLC) is the most prevalent type of lung cancer and the most difficult to predict. When there are no distant metastases, the optimal therapy depends mainly on whether there are malignant lymph nodes in the mediastinum. Given the vigorous debate among specialists about which tests should be used, our goal was to determine the optimal sequence of tests for each patient. We have built an influence diagram (ID) that represents the possible tests, their costs, and their outcomes. This model is equivalent to a decision tree containing millions of branches. In the first evaluation, we only took into account the clinical outcomes (effectiveness). In the second, we used a willingness-to-pay of € 30,000 per quality adjusted life year (QALY) to convert economic costs into effectiveness. We assigned a second-order probability distribution to each parameter in order to conduct several types of sensitivity analysis. Two strategies were obtained using two different criteria. When considering only effectiveness, a positive computed tomography (CT) scan must be followed by a transbronchial needle aspiration (TBNA), an endobronchial ultrasound (EBUS), and an endoscopic ultrasound (EUS). When the CT scan is negative, a positron emission tomography (PET), EBUS, and EUS are performed. If the TBNA or the PET is positive, then a mediastinoscopy is performed only if the EBUS and EUS are negative. If the TBNA or the PET is negative, then a mediastinoscopy is performed only if the EBUS and the EUS give contradictory results. When taking into account economic costs, a positive CT scan is followed by a TBNA; an EBUS is done only when the CT scan or the TBNA is negative. This recommendation of performing a TBNA in certain cases should be discussed by the pneumology community because TBNA is a cheap technique that could avoid an EBUS, an expensive test, for many patients. We have determined the optimal sequence of tests for the mediastinal staging of NSCLC by considering sensitivity, specificity, and the economic cost of each test. The main novelty of our study is the recommendation of performing TBNA whenever the CT scan is positive. Our model is publicly available so that different experts can populate it with their own parameters and re-examine its conclusions. It is therefore proposed as an evidence-based instrument for reaching a consensus.

  10. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  11. [Joint application of 7 interventional pulmonology methods in early diagnosis of lung cancer].

    PubMed

    Jin, Fa-Guang; Li, Wang-Ping; Mu, De-Guang; Chu, Dong-Ling; Fu, En-Qing; Xie, Yong-Hong; Lu, Jing-Li; Sun, Ya-Ni

    2009-06-23

    To evaluate the combination of 7 interventional pulmonology methods in early diagnosis of lung cancer. A total of 467 patients with thoracic and pulmonary lesions (include hilum pulmonis lymphadenectasis, mediastinal lymphadenectasis, pulmonary scobination, lump, lamellar infiltration, small amount of pleural fluid and pleural scobination) had negative results via exfoliative cytology, bacteriology and routine bronchoscopy. All these patients had ultrathin bronchoscopy with biopsy and brushing. For those 155 cases whose foci were located at porta pulmonis, inner zone or median zone, the authors applied ultrathin bronchoscopy with biopsy and brushing guided by X-ray. For those 95 cases whose foci were located at median zone or outer zone and unconnected with chest wall, per cutem lung puncture needle aspiration was employed under the guidance of X-ray. For those 102 cases whose foci were tightly connected with pleural membrane, per cutem lung puncture biopsy was employed under the guidance of type-B ultrasonic. For those 59 cases with suspected central airway foci, auto-fluorescence bronchoscopic biopsy and brushing were employed. For those 67 cases with hilum pulmonis or mediastinal lymphadenectasis, endobronchial ultrasonic transbronchial needle aspiration (EBUS-TBNA) was employed. For those 23 cases with small amount of pleural fluid or pleural scobination, electronic thoracoscopic biopsy and brushing were employed. It was found that 118 cases were diagnosed by ultrathin bronchoscopic biopsy and brushing with a positive rate of 25.3% (118/467), 105 cases by ultrathin bronchoscopy with biopsy and brushing guided by X-ray with a positive rate of 67.7% (105/155), 63 cases by per cutem lung puncture needle aspiration under the guidance of X-ray with a positive rate of 66.3% (63/95), 69 cases by per cutem lung puncture biopsy under the guidance of type-B ultrasound with a positive rate of 67.6% (69/102), 18 cases by auto-fluorescence bronchoscopic biopsy and brushing with a positive rate of 35.3% (18/51), 52 cases by EBUS-TBNA with a positive rate of 77.6% (52/67), 12 cases by electronic thoracoscopic biopsy and brushing with a positive rate of 52.2% (12/23). The total positive diagnostic rate was 93.6% (437/467). And the diagnostic rate of < or = stage II lung cancer (3 cases carcinoma in situ, 84 stage I a, 63 stage Ib, 65 stage IIa and 44 stage IIb) was 82.7% (259/313). Joint application of these 7 interventional bronchoscopic techniques can significantly boost the rate of early diagnosis of lung cancer.

  12. EBUS-STAT Subscore Analysis to Predict the Efficacy and Assess the Validity of Virtual Reality Simulation for EBUS-TBNA Training Among Experienced Bronchoscopists.

    PubMed

    Scarlata, Simone; Palermo, Patrizio; Candoli, Piero; Tofani, Ariela; Petitti, Tommasangelo; Corbetta, Lorenzo

    2017-04-01

    Linear endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) represents a pivotal innovation in interventional pulmonology; determining the best approach to guarantee systematic and efficient training is expected to become a main issue in the forthcoming years. Virtual reality simulators have been proposed as potential EBUS-TBNA training instruments, to avoid unskilled beginners practicing directly in real-life settings. A validated and perfected simulation program could be used before allowing beginners to practice on patients. Our goal was to test the reliability of the EBUS-Skills and Task Assessment Tool (STAT) and its subscores for measuring the competence of experienced bronchoscopists approaching EBUS-guided TBNA, using only the virtual reality simulator as both a training and an assessment tool. Fifteen experienced bronchoscopists, with poor or no experience in EBUS-TBNA, participated in this study. They were all administered the Italian version of the EBUS-STAT evaluation tool, during a high-fidelity virtual reality simulation. This was followed by a single 7-hour theoretical and practical (on simulators) session on EBUS-TBNA, at the end of which their skills were reassessed by EBUS-STAT. An overall, significant improvement in EBUS-TBNA skills was observed, thereby confirming that (a) virtual reality simulation can facilitate practical learning among practitioners, and (b) EBUS-STAT is capable of detecting these improvements. The test's overall ability to detect differences was negatively influenced by the minimal variation of the scores relating to items 1 and 2, was not influenced by the training, and improved significantly when the 2 items were not considered. Apart from these 2 items, all the remaining subscores were equally capable of revealing improvements in the learner. Lastly, we found that trainees with presimulation EBUS-STAT scores above 79 did not show any significant improvement after virtual reality training, suggesting that this score represents a cutoff value capable of predicting the likelihood that simulation can be beneficial. Virtual reality simulation is capable of providing a practical learning tool for practitioners with previous experience in flexible bronchoscopy, and the EBUS-STAT questionnaire is capable of detecting these changes. A pretraining EBUS-STAT score below 79 is a good indicator of those candidates who will benefit from the simulation training. Further studies are needed to verify whether a modified version of the questionnaire would be capable of improving its performance among experienced bronchoscopists.

  13. Endobronchial ultrasound-guided transbronchial needle aspiration: performance of biomedical scientists on rapid on-site evaluation and preliminary diagnosis.

    PubMed

    Schacht, M J; Toustrup, C B; Madsen, L B; Martiny, M S; Larsen, B B; Simonsen, J T

    2016-10-01

    Rapid on-site evaluation (ROSE) of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) followed by a subsequent preliminary adequacy assessment and a preliminary diagnosis, was performed at Aarhus University Hospital by biomedical scientists (BMS). The aim of this study was to evaluate the BMS accuracy of ROSE adequacy assessment, the preliminary adequacy assessment and the preliminary diagnosis as compared with the cytopathologist-rendered final adequacy assessment and final diagnosis. The BMS-rendered assessments for 717 sites from 319 consecutive patients over a 4-month period were compared with the cytopathologist-rendered assessments. Comparisons of adequacy and preliminary diagnoses were based on inter-observer Cohen's Kappa coefficient with a 95% confidence interval (CI). Strong correlations between ROSE and final adequacy assessments [Kappa coefficient of 0.90 (CI: 0.85-0.96)] and between the preliminary and final adequacy assessments [Kappa coefficient of 0.93 (CI: 0.87-0.99)] were found. As for the correlation between the preliminary and final diagnoses, the Kappa coefficient was 0.99 (CI: 0.98-1). Both ROSE and preliminary adequacy assessments as well as preliminary diagnoses, all performed by BMS, were highly accurate when compared with the final assessment by the cytopathologist. © 2016 John Wiley & Sons Ltd.

  14. Endobronchial Ultrasound for Nodal Staging of Non-Small Cell Lung Cancer Patients with Radiologically Normal Mediastinum: A Meta-Analysis.

    PubMed

    El-Osta, Hazem; Jani, Pushan; Mansour, Ali; Rascoe, Philip; Jafri, Syed

    2018-04-23

    An accurate assessment of the mediastinal lymph nodes status is essential in the staging and treatment planning of potentially resectable non-small cell lung cancer (NSCLC). We performed this meta-analysis to evaluate the role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in detecting occult mediastinal disease in NSCLC with no radiologic mediastinal involvement. The PubMed, Embase, and Cochrane libraries were searched for studies describing the role of EBUS-TBNA in lung cancer patients with radiologically negative mediastinum. The individual and pooled sensitivity, prevalence, negative predictive value (NPV), and diagnostic odds ratio (DOR) were calculated using the random effects model. Metaregression analysis, heterogeneity, and publication bias were also assessed. A total of 13 studies that met the inclusion criteria were included in the meta-analysis. The pooled effect size of the different diagnostic parameters were estimated as follows: prevalence, 12.8% (95% CI, 10.4%-15.7%); sensitivity, 49.5% (95% confidence interval [CI], 36.4%-62.6%); NPV, 93.0% (95% CI, 90.3%-95.0%); and log DOR, 5.069 (95% CI, 4.212-5.925). Significant heterogeneity was noticeable for the sensitivity, disease prevalence, and NPV, but not observed for log DOR. Publication bias was detected for sensitivity, NPV and log DOR but not for prevalence. Bivariate meta-regression analysis showed no significant association between the pooled calculated parameters and the type of anesthesia, imaging utilized to define negative mediastinum, rapid on-site test usage, and presence of bias by QUADAS-2 tool. Interestingly, we observed a greater sensitivity, NPV and log DOR for studies published prior to 2010, and for prospective multicenter studies. Among NSCLC patients with a radiologically normal mediastinum, the prevalence of mediastinal disease is 12.8% and the sensitivity of EBUS-TBNA is 49.5%. Despite the low sensitivity, the resulting NPV of 93.0% for EBUS-TBNA suggests that mediastinal metastasis is uncommon in such patients.

  15. Endosonography-related mortality and morbidity for pulmonary indications: a nationwide survey in the Netherlands.

    PubMed

    von Bartheld, Martin B; Annema, Jouke T

    2015-12-01

    Endosonography is being implemented rapidly in pulmonary medicine for the diagnosis and staging of lung cancer, the assessment of sarcoidosis, and the assessment of mediastinal lesions. Although serious adverse events (SAEs) have been described, safety data outside cohort studies are scarce. To assess the SAE and mortality rate of EUS-guided FNA (EUS-FNA) and endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) for mediastinal and/or hilar analysis. Nationwide, retrospective survey by using questionnaires. All hospitals in the Netherlands. All patients undergoing EUS-FNA and EBUS-TBNA for intrathoracic analysis in the period 1999 to 2011. EUS-FNA and EBUS-TBNA. Occurrence of fatal outcomes and SAEs. Detailed information was obtained for each reported case, and all cases were reviewed independently by 2 investigators, including identification of risk factors. All 89 hospitals (100%) responded. An estimated 14,075 EUS-FNA and 2675 EBUS procedures were performed. Seven patients died after endosonography (5 EUS-FNA, 2 EBUS [mortality rate 0.04%]). All fatalities occurred in patients of poor performance status (American Society of Anesthesiologists Physical Status Classification System score of III/IV). Twenty-five SAEs were reported (22 EUS-FNA, 3 EBUS [SAE rate of 0.15%; EUS-FNA 0.16%, EBUS 0.11%]). SAEs were mostly (64%) of infectious origin. No specific risk factors for infectious adverse events could be identified. Retrospective study, possible recall bias, overrepresentation of EUS-FNA cases. Endosonography appears to be a safe technique for the analysis of mediastinal and/or hilar lesions. Poor performance status is a risk factor for fatal outcomes. Mediastinitis and/or mediastinal abscess formation is rare but is a potential and dangerous adverse event of endosonography. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  16. A Prediction Model to Help with the Assessment of Adenopathy in Lung Cancer: HAL.

    PubMed

    O'Connell, Oisin J; Almeida, Francisco A; Simoff, Michael J; Yarmus, Lonny; Lazarus, Ray; Young, Benjamin; Chen, Yu; Semaan, Roy; Saettele, Timothy M; Cicenia, Joseph; Bedi, Harmeet; Kliment, Corrine; Li, Liang; Sethi, Sonali; Diaz-Mendoza, Javier; Feller-Kopman, David; Song, Juhee; Gildea, Thomas; Lee, Hans; Grosu, Horiana B; Machuzak, Michael; Rodriguez-Vial, Macarena; Eapen, George A; Jimenez, Carlos A; Casal, Roberto F; Ost, David E

    2017-06-15

    Estimating the probability of finding N2 or N3 (prN2/3) malignant nodal disease on endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with non-small cell lung cancer (NSCLC) can facilitate the selection of subsequent management strategies. To develop a clinical prediction model for estimating the prN2/3. We used the AQuIRE (American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education) registry to identify patients with NSCLC with clinical radiographic stage T1-3, N0-3, M0 disease that had EBUS-TBNA for staging. The dependent variable was the presence of N2 or N3 disease (vs. N0 or N1) as assessed by EBUS-TBNA. Univariate followed by multivariable logistic regression analysis was used to develop a parsimonious clinical prediction model to estimate prN2/3. External validation was performed using data from three other hospitals. The model derivation cohort (n = 633) had a 25% prevalence of malignant N2 or N3 disease. Younger age, central location, adenocarcinoma histology, and higher positron emission tomography-computed tomography N stage were associated with a higher prN2/3. Area under the receiver operating characteristic curve was 0.85 (95% confidence interval, 0.82-0.89), model fit was acceptable (Hosmer-Lemeshow, P = 0.62; Brier score, 0.125). We externally validated the model in 722 patients. Area under the receiver operating characteristic curve was 0.88 (95% confidence interval, 0.85-0.90). Calibration using the general calibration model method resulted in acceptable goodness of fit (Hosmer-Lemeshow test, P = 0.54; Brier score, 0.132). Our prediction rule can be used to estimate prN2/3 in patients with NSCLC. The model has the potential to facilitate clinical decision making in the staging of NSCLC.

  17. Cytological preparations for molecular analysis: A review of technical procedures, advantages and limitations for referring samples for testing.

    PubMed

    da Cunha Santos, G; Saieg, M A; Troncone, G; Zeppa, P

    2018-04-01

    Minimally invasive procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) must yield not only good quality and quantity of material for morphological assessment, but also an adequate sample for analysis of molecular markers to guide patients to appropriate targeted therapies. In this context, cytopathologists worldwide should be familiar with minimum requirements for refereeing cytological samples for testing. The present manuscript is a review with comprehensive description of the content of the workshop entitled Cytological preparations for molecular analysis: pre-analytical issues for EBUS TBNA, presented at the 40th European Congress of Cytopathology in Liverpool, UK. The present review emphasises the advantages and limitations of different types of cytology substrates used for molecular analysis such as archival smears, liquid-based preparations, archival cytospin preparations and FTA (Flinders Technology Associates) cards, as well as their technical requirements/features. These various types of cytological specimens can be successfully used for an extensive array of molecular studies, but the quality and quantity of extracted nucleic acids rely directly on adequate pre-analytical assessment of those samples. In this setting, cytopathologists must not only be familiar with the different types of specimens and associated technical procedures, but also correctly handle the material provided by minimally invasive procedures, ensuring that there is sufficient amount of material for a precise diagnosis and correct management of the patient through personalised care. © 2018 John Wiley & Sons Ltd.

  18. The additional role of Xpert MTB/RIF in the diagnosis of intrathoracic tuberculous lymphadenitis.

    PubMed

    Lee, Jinwoo; Choi, Sun Mi; Lee, Chang-Hoon; Lee, Sang-Min; Yim, Jae-Joon; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Park, Young Sik

    2017-06-01

    Diagnosis of intrathoracic tuberculosis (TB) lymphadenitis remains a challenge because of difficulties in obtaining adequate tissue and the lack of a sensitive test. Recently, Xpert MTB/RIF assay is being used for rapid diagnosis of pulmonary TB, but it has not yet been widely validated in intrathoracic TB lymphadenitis. The aim of this study was to assess the additional role of Xpert MTB/RIF in diagnosing intrathoracic TB lymphadenitis using endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) specimen. Consecutive patients who underwent Xpert MTB/RIF assay using EBUS-TBNA specimen from January 2012 and November 2013 at a tertiary referral hospital were recruited. Among them, the cases with malignant lymph nodes were excluded. Among 73 patients, 13 (17.8%) cases were diagnosed with intrathoracic TB lymphadenitis. In detail, 10 patients were diagnosed using conventional methods only (histology or AFB culture) and 3 patients were additionally diagnosed when adding Xpert MTB/RIF assay. The median time to diagnosis using Xpert MTB/RIF (1 day) was shorter than conventional methods (3 days for histology, 14 days for AFB culture). Rifampin resistance was not detected in any patients. In patients with enlarged intrathoracic lymph nodes and low suspicion of malignancy, combination of conventional diagnostic methods with Xpert MTB/RIF could lead to additional and rapid diagnosis of intrathoracic TB lymphadenitis. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Role of Xpert MTB/RIF in differentiating tuberculosis from sarcoidosis in patients with mediastinal lymphadenopathy undergoing EBUS-TBNA: a study of 147 patients.

    PubMed

    Dhooria, Sahajal; Gupta, Nalini; Bal, Amanjit; Sehgal, Inderpaul Singh; Aggarwal, Ashutosh Nath; Sethi, Sunil; Behera, Digambar; Agarwal, Ritesh

    2016-10-07

    In patients with intrathoracic lymphadenopathy, differentiating tuberculosis from sarcoidosis is often difficult. We hypothesized that Xpert MTB/RIF assay, a semi-automated hemi-nested PCR would help in this regard. To evaluate the performance of Xpert MTB/RIF in the differential diagnosis of tuberculosis and sarcoidosis. This was a retrospective analysis of patients with intrathoracic lymphadenopathy who underwent endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA), and were diagnosed as either tuberculosis or sarcoidosis. The results of Xpert MTB/RIF assay, tuberculin skin test and endosonographic characteristics (heterogeneous echotexture and coagulation necrosis sign) of the lymph nodes were compared between the two groups. During the study period, 465 EBUS procedures were performed and a diagnosis of sarcoidosis (n=94) or tuberculosis (n=53) was made in 147 patients. Xpert MTB/RIF was positive in 26 (49.1%) and two (2.1%) patients with tuberculosis and sarcoidosis, respectively. The sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF in the diagnosis of tuberculosis were 49.1 %, 97.9%, 92.9% and 77.3%, respectively. The presence of any of the four features namely positive Xpert MTB/RIF, positive tuberculin skin test, heterogeneous echotexture of the lymph nodes, or the presence of endosonographic coagulation necrosis sign yielded a sensitivity and negative predictive value of 83.0% and 88.0%, respectively in the diagnosis of tuberculosis versus sarcoidosis. Xpert MTB/RIF has good specificity and positive predictive value in the diagnosis of tuberculosis, and is a useful investigation in separating tuberculosis from sarcoidosis.

  20. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  1. A new posterior iliac puncture/aspiration needle.

    PubMed

    Islam, Anwarul

    2016-03-25

    The needles that are currently used for obtaining bone marrow aspirate samples from the posterior ilium are typically those of 1930s vintage (eg, Klima, Salah or similar needles), which were specifically designed for sternal aspiration. These needles are not designed to obtain bone marrow aspirate samples from the posterior ilium and as a result they are unsatisfactory particularly if the patient is large or obese. A new posterior iliac puncture/aspiration needle has therefore been designed, which is particularly suited for bone marrow aspiration from the posterior ilium. The needle was tested on five cadavers and on five patients. The design and construction of the needle was found to be satisfactory and a marked improvement over the conventional sternal puncture needles particularly when large or obese patients were concerned. The new posterior iliac bone marrow aspiration needle has advantages that overcome the limitations of using a conventional sternal puncture needle to obtain marrow aspirates from the posterior ilium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.

  3. Determinants of Practice Patterns and Quality Gaps in Lung Cancer Staging and Diagnosis

    PubMed Central

    Niu, Jiangong; Elting, Linda S.; Buchholz, Thomas A.; Giordano, Sharon H.

    2014-01-01

    Background: Guidelines recommend mediastinal lymph node sampling as the first invasive diagnostic procedure in patients with suspected lung cancer with mediastinal lymphadenopathy without distant metastases. Methods: Patients were a retrospective cohort of 15,316 patients with lung cancer with regional spread without metastatic disease in the National Cancer Institute’s Surveillance, Epidemiology, and End Results (SEER) or Texas Cancer Registry Medicare-linked databases. Patients were categorized based on the sequencing of invasive diagnostic tests performed: (1) evaluation consistent with guidelines, mediastinal sampling done first; (2) evaluation inconsistent with guidelines, non-small cell lung cancer (NSCLC) present, mediastinal sampling performed but not as part of the first invasive test; (3) evaluation inconsistent with guidelines, NSCLC present, mediastinal sampling never done; and (4) evaluation inconsistent with guidelines, small cell lung cancer. The primary outcome was whether guideline-consistent care was delivered. Secondary outcomes included whether patients with NSCLC ever had mediastinal sampling and use of transbronchial needle aspiration (TBNA) among pulmonologists. Results: Only 21% of patients had a diagnostic evaluation consistent with guidelines. Only 56% of patients with NSCLC had mediastinal sampling prior to treatment. There was significant regional variability in guideline-consistent care (range, 12%-29%). Guideline-consistent care was associated with lower patient age, metropolitan areas, and if the physician ordering or performing the test was male, trained in the United States, had seen more patients with lung cancer, and was a pulmonologist or thoracic surgeon who had graduated more recently. More recent pulmonary graduates were also more likely to perform TBNA (P < .001). Conclusions: Guideline-consistent care varied regionally and was associated with physician-level factors, suggesting that a lack of effective physician training may be contributing to the quality gaps observed. PMID:24202651

  4. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types

    PubMed Central

    Lytvynchuk, Lyubomyr; Sergienko, Andrij; Savytska, Iryna; Albert, Réka; Glittenberg, Carl; Binder, Susanne; Petrovski, Goran

    2017-01-01

    A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI) using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G) and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements. PMID:28692684

  5. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  6. Diagnosis of clinical bovine mastitis by fine needle aspiration followed by staining and scanning electron microscopy in a Prototheca zopfii outbreak.

    PubMed

    da Costa, Elizabeth Oliveira; Ribeiro, Márcio Garcia; Ribeiro, Andréa Rentz; Rocha, Noeme Sousa; de Nardi Júnior, Geraldo

    2004-07-01

    Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

  7. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.

    1996-09-15

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnosticmore » tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles.« less

  8. Extraction and visualization of the central chest lymph-node stations

    NASA Astrophysics Data System (ADS)

    Lu, Kongkuo; Merritt, Scott A.; Higgins, William E.

    2008-03-01

    Lung cancer remains the leading cause of cancer death in the United States and is expected to account for nearly 30% of all cancer deaths in 2007. Central to the lung-cancer diagnosis and staging process is the assessment of the central chest lymph nodes. This assessment typically requires two major stages: (1) location of the lymph nodes in a three-dimensional (3D) high-resolution volumetric multi-detector computed-tomography (MDCT) image of the chest; (2) subsequent nodal sampling using transbronchial needle aspiration (TBNA). We describe a computer-based system for automatically locating the central chest lymph-node stations in a 3D MDCT image. Automated analysis methods are first run that extract the airway tree, airway-tree centerlines, aorta, pulmonary artery, lungs, key skeletal structures, and major-airway labels. This information provides geometrical and anatomical cues for localizing the major nodal stations. Our system demarcates these stations, conforming to criteria outlined for the Mountain and Wang standard classification systems. Visualization tools within the system then enable the user to interact with these stations to locate visible lymph nodes. Results derived from a set of human 3D MDCT chest images illustrate the usage and efficacy of the system.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less

  10. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  11. Guided percutaneous fine-needle aspiration biopsy of the liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, C.S.; McLoughlin, M.J.; Tao, L.C.

    1981-04-01

    Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less

  12. Thin-needle aspiration biopsy of the prostate.

    PubMed

    Koss, L G; Woyke, S; Schreiber, K; Kohlberg, W; Freed, S Z

    1984-05-01

    The authors summarize the current status of thin-needle aspiration biopsy of the prostate and evaluate the accomplishments and limitations of this method of diagnosis. Historical developments, indications, technique, contraindications, complications, cytology of aspirates, diagnostic efficacy of aspirates, and grading of prostatic carcinomas are discussed.

  13. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    PubMed

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  14. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    PubMed Central

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  15. Toxoplasma lymphadenitis diagnosed by fine-needle aspiration cytology: a rare finding.

    PubMed

    Hosokawa, S; Kusama, Y; Ono, T; Mineta, H

    2014-06-01

    There are only very few reports of cervical toxoplasma lymphadenitis being diagnosed exclusively via fine-needle aspiration cytology (with serology). We describe a case of toxoplasma lymphadenitis that was successfully diagnosed by fine-needle aspiration cytology. The case involved a male patient who was immunocompromised as a result of recurrent acute myelogenous leukaemia with cervical lymphadenopathy. The biopsy showed typical features of a well-defined pseudocyst containing Toxoplasma gondii tachyzoites. Toxoplasma lymphadenitis is a common cause of lymph node enlargement. Fine-needle aspiration cytology is a useful method for diagnosing and differentiating toxoplasma lymphadenitis from more serious causes of lymphadenopathy, such as metastatic lymphadenopathy or lymphoma.

  16. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Ferro, Carlo

    2011-02-15

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsymore » of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.« less

  17. [Endobronchial Ultrasound (EBUS) - an Update 2017].

    PubMed

    Darwiche, K; Özkan, F; Wolters, C; Eisenmann, S

    2017-11-01

    Endobronchial Ultrasound (EBUS) with the two modalities curved and radial EBUS significantly improved the diagnostics in several pulmonary diseases. The examination and staging of mediastinal and hilar lymph nodes in patients with known or suspected lung malignancy as well as the evaluation of unknown pulmonary or mediastinal lesions can be achieved with minimal invasive means when using EBUS. More invasive surgical procedures for diagnostic purposes can be omitted. The diagnostic yield also increases when EBUS is applied in sarcoidosis or mediastinal lymph node tuberculosis but only to some extend in case of lymphoma. Samples obtained by EBUS-TBNA should be handled efficiently to allow molecular analysis in lung cancer. EBUS is a safe procedure, and complication rate is extremely low. Further advances of the EBUS technology focus on improving analysis of the information provided by the ultrasound image and a better tissue sampling by developing of new EBUS bronchoscopes and TBNA-needles. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Thyroid Swelling and Thyroiditis in the Setting of Recent hCG Injections and Fine Needle Aspiration

    PubMed Central

    Lamos, Elizabeth M.; Munir, Kashif M.

    2016-01-01

    A 60-year-old woman presented with a neck mass and underwent fine needle aspiration of a left thyroid nodule. During this time, she had been injected with hCG for weight loss. Soon after, she developed rapid diffuse thyroid growth with pain. She was ultimately diagnosed with thyrotoxicosis due to postaspiration subacute thyroiditis and subsequently became hypothyroid. This condition is rare in the nonpregnant state in noncystic nodules with a smaller needle gauge approach. The incidence of thyroid nodule discovery and evaluation is increasing. As more procedures are undertaken, understanding of potential complications is important. This case highlights potential complications of thyroid fine needle aspiration including diffuse thyroid swelling and thyroiditis. The role of hCG injections is speculated to have potentially stimulated thyroid follicular epithelium via cross-reactivity with the TSH receptor and contributed to the acute inflammatory response after fine needle aspiration. PMID:26942022

  19. Stereotaxic fine-needle aspiration of low-suspicion, nonpalpable breast nodules: valid alternative to follow-up mammography.

    PubMed

    Franquet, T; Cozcolluela, R; De Miguel, C

    1992-06-01

    Seventy "low-suspicion," nonpalpable solid breast nodules were evaluated with stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography. Sonography was performed in all cases to determine the solid nature of the nodules. Eight cysts were incorrectly classified with sonography, corresponding to atypical cysts; in such cases, however, stereotaxic fine-needle aspiration not only enabled the diagnosis, but was therapeutic as well. Fifty-eight of 70 breast aspirates (83%) yielded adequate cellular material for cytologic interpretation. A specific cytologic diagnosis was made in 52 cases (51 benign, one malignant). Insufficient cytologic material was obtained in 12 cases (17%). These results should help establish the validity of stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography in patients with low-suspicion, solid breast nodules, reducing radiation exposure, patient anxiety, unnecessary biopsies, and costs.

  20. Needle Biopsy

    MedlinePlus

    ... needle biopsy procedures include fine-needle aspiration and core needle biopsy. Needle biopsy may be used to ... hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses ...

  1. Ovum pick-up in sheep: a comparison between different aspiration devices for optimal oocyte retrieval.

    PubMed

    Rodríguez, C; Anel, L; Alvarez, M; Anel, E; Boixo, J C; Chamorro, C A; de Paz, P

    2006-04-01

    In vivo ovum pick-up (OPU) in sheep may be improved with a proper choice of aspiration elements (needle and tubing) and aspiration vacuum pressure. In the present study, two experiments were carried out. In Expt 1, visible follicles in ovaries of slaughtered ewes (treated separately according to their diameters: small<3 mm, medium 3-5 mm and large>5 mm) were aspirated using different combinations of the three studied factors such as aspiration flow rate (10, 20, 30, 40 and 50 ml water/min), needle gauge (18 and 20 G) and tubing inner diameter (1, 2 or 3 mm internal diameter). In Expt 2, a study with two 18 G needles of different lengths (18 G: 82 mm; 18 GL: 600 mm) was carried out, using ovaries obtained post-mortem, and performing in vivo laparoscopic follicular aspiration on ewes. We considered good quality oocytes as those with both complete compact cumulus and a homogeneous cytoplasm. Recovery rate, proportion of good quality oocytes (good quality oocytes/100 oocytes recovered) and overall efficiency (good quality oocytes/100 follicles aspirated) were noted. In Expt 1, aspiration flow rate affect remarkable proportion of good quality oocytes (69.5%, 50.5%, 44.8%, 36.5% and 28.3% for flows from 10 to 50 ml/min respectively, p<0.05). Needle gauge did not affect aspiration device efficiency. Thin and intermediate tubings were more effective (overall efficiency rates: 34.9%, 32.3% and 28.1% for 1, 2 and 3 mm respectively, p<0.05). Follicle size did not affect recovery rate, but proportion of good quality oocytes was higher for large (77.9%) and medium (64.4%) follicles (p<0.05). Finally, some combinations of the aspiration device showed greater effectiveness. In Expt 2, needle length did not influence recovery rate, but good quality oocytes rate was significantly modified both post-mortem and in vivo (good quality rate for 18 G vs 18 GL needles: 69.5% vs 47.7% and 58.1% vs 25.4%, post-mortem and in vivo respectively, p<0.05). We conclude that low-aspiration flow rates (10 and 20 ml/min) with thin or intermediate tubings (1 and 2 mm), and any short needle (18 G or 20 G) are the most adequate aspiration factors for OPU in sheep.

  2. Presenting hydrothorax predicts failure of needle aspiration in primary spontaneous pneumothorax.

    PubMed

    Wu, Kwok Kei; Lui, Chun Tat; Ho, Chik Leung; Tsui, Kwok Leung; Fung, Hin Tat

    2016-06-01

    The objective was to evaluate if existence of hydrothorax in initial chest radiograph predicts treatment outcome in patients with primary spontaneous pneumothorax who received needle thoracostomy. This is a retrospective cohort study carried out from January 2011 to August 2014 in 1 public hospital in Hong Kong. All consecutive adult patients aged 18years or above who attended the emergency department with the diagnosis of primary spontaneous pneumothorax with needle aspiration performed as primary treatment were included. Age, smoking status, size of pneumothorax, previous history of pneumothorax, aspirated gas volume and presence of hydropneumothorax in initial radiograph were included in the analysis. The outcome was success or failure of the needle aspiration. Logistic regression was used to identify the predicting factors of failure of needle aspiration. There were a total of 127 patients included. Seventy-three patients (57.5%) were successfully treated with no recurrence upon discharge. Among 54 failure cases, 13 patients (10.2%) failed immediately after procedure as evident by chest radiograph and required second treatment. Forty-one patients (32.3%) failed upon subsequent chest radiographs. Multivariate logistic regression showed factors independently associated with the failure of needle aspiration, which included hydropneumothorax in the initial radiograph (odds ratio [OR]=4.47 [1.56i12.83], P=.005), previous history of pneumothorax (OR=3.92 [1.57-9.79], P=.003), and large size of pneumothorax defined as apex-to-cupola distance ≥5cm (OR=2.75 [1.21-6.26], P=.016). Hydropneumothorax, previous history of pneumothorax, and large size were independent predictors of failure of needle aspiration in treatment of primary spontaneous pneumothorax. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Novel Magnetic Resonance Detection and Profiling of Ovarian Cancer Across Specimens

    DTIC Science & Technology

    2012-10-01

    Cancer Cells in Fine - Needle Aspirates. Proc. Natl. Acad. Sci. U.S.A. 2009, 106, 12459–12464. 25. Han,H. S.; Devaraj,N. K.; Lee, J.; Hilderbrand, S.A... fine needle aspirates, biopsies, ascites, blood, sputum), which are inherently complex in composition, as well as heterogeneous and variable in cell...in ascitic fluid, we anticipate that this method could similarly be applied to fine needle aspirates, blood, biopsy spec- imens, sputum, and other

  4. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  5. Needle aspiration versus intercostal tube drainage for pneumothorax in the newborn.

    PubMed

    Bruschettini, Matteo; Romantsik, Olga; Ramenghi, Luca Antonio; Zappettini, Simona; O'Donnell, Colm P F; Calevo, Maria Grazia

    2016-01-11

    Pneumothorax occurs more frequently in the neonatal period than at any other time of life and is associated with increased mortality and morbidity. It may be treated with either needle aspiration or insertion of a chest tube. The former consists of aspiration of air with a syringe through a needle or an angiocatheter, usually through the second or third intercostal space in the midclavicular line. The chest tube is usually placed in the anterior pleural space passing through the sixth intercostal space into the pleural opening, turned anteriorly and directed to the location of the pneumothorax, and then connected to a Heimlich valve or an underwater seal with continuous suction. To compare the efficacy and safety of needle aspiration and intercostal tube drainage in the management of neonatal pneumothorax. We used the standard search strategy of the Cochrane Neonatal Review group to search the Cochrane Central Register of Controlled Trials (CENTRAL 2015, Issue 11), MEDLINE via PubMed (1966 to 30 November 2015), EMBASE (1980 to 30 November 2015), and CINAHL (1982 to 30 November 2015). We also searched clinical trials databases, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. Randomised controlled trials, quasi-randomised controlled trials and cluster trials comparing needle aspiration (either with the needle or angiocatheter left in situ or removed immediately after aspiration) to intercostal tube drainage in newborn infants with pneumothorax. For each of the included trial, two authors independently extracted data (e.g. number of participants, birth weight, gestational age, kind of needle and chest tube, choice of intercostal space, pressure and device for drainage) and assessed the risk of bias (e.g. adequacy of randomisation, blinding, completeness of follow-up). The primary outcomes considered in this review are mortality during the neonatal period and during hospitalisation. One randomised controlled trial (72 infants) met the inclusion criteria of this review. We found no differences in the rates of mortality (risk ratio (RR) 1.50, 95% confidence interval (CI) 0.27 to 8.45) or complications related to the procedure. After needle aspiration, the angiocatheter was left in situ (mean 27.1 hours) and not removed immediately after the aspiration. The angiocatheter was in place for a shorter duration than the intercostal tube (mean difference (MD) -11.20 hours, 95% CI -15.51 to -6.89). None of the 36 newborns treated with needle aspiration with the angiocatheter left in situ required the placement of an intercostal tube drainage. Overall, the quality of the evidence supporting this finding is low. At present there is insufficient evidence to determine the efficacy and safety of needle aspiration versus intercostal tube drainage in the management of neonatal pneumothorax. Randomised controlled trials comparing the two techniques are warranted.

  6. Primary cutaneous aspergillosis from Tamilnadu diagnosed by fine needle aspiration cytology

    PubMed Central

    Venugopal, Taralakshmi V.; Venugopal, Pankajalakshmi V.

    2012-01-01

    Aspergillus are ubiquitous and more than 30 species have been reported to be involved in human infection. Most of the cases occur in immunocompromised patients and are disseminated in the blood. Primary cutaneous aspergillosis in immunocompetent hosts is rare. We report a unique case of primary cutaneous aspergillosis in an immunocompetent patient diagnosed by fine needle aspiration cytology. The characteristic ascocarp and ascospores of Aspergillus species were found in the aspirate and Aspergillus glaucus was isolated in pure culture. The case is presented to increase the awareness of the usefulness of fine needle aspiration cytology for diagnosing fungal infections. PMID:24371752

  7. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration.

    PubMed

    Arakawa, H; Nakajima, Y; Kurihara, Y; Niimi, H; Ishikawa, T

    1996-07-01

    We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.

  8. [Values and limits in fine needle aspiration in the diagnosis of Warthin tumour of the parotid gland].

    PubMed

    Righi, A; Foschini, M P

    2006-12-01

    Recent paper state that cytological diagnosis of Warthin Tumour of the parotid gland is poorly reproducible and that aspiration procedures damage the tumoral tissue as to make difficult the histological diagnosis. Aim of the present study is to review cytological sampling performed with fine needle sampling without aspiration and to compare them with the relative surgical specimens in order to determine the value of fine needle aspiration in the diagnosis of Warthin Tumour and to quantify' the damage in histological tissue. All cases with cytological and/or histological diagnosis of Warthin Tumour during the period 1/1/98 to 30/6/04 were retrieved. In all cases both cytological and histological slides were reviewed and compared. In all cases fine needle aspiration (FNA) was performed according to the technique described by Zajdela et al. in 1987. A cytologic sample was considered diagnostic when there were in the same sample mucoid substance, lymphocytes scattered with a range of maturation and oncocytes organized in flat sheets of cells. 38 cases were selected corresponding to 37 patients (1 case of Warthin Tumour bilateral): all tumors were localized in the parotid gland. Fine needle sampling were 43. Nine cytological sample (20.9%) were inadequate. Sensitivity and specificity, in the preent series, had the same value, being 97.1%. A spectrum of histologic alterations were observed in 30/38 cases (79%). These alterations were squamous metaplasia (7 cases), acute and chronic hemorrhage and inflammation with multinucleated giant cells (26 cases) and granulation tissue with subsequent fibrosis (24 cases). In all cases the histologic alterations from fine needle were focal, limited to less than 20% of the tumoral area (first category of Batsakis 'classification), and did not prevent the histologic diagnosis of Warthin Tumour. These data suggest that fine needle aspiration without aspiration is a valuable tool for the per-operative diagnosis of Warthin Tumour. In addition it creates only minor histological changes, that always allow the histological diagnosis.

  9. First Evaluation of the New Thin Convex Probe Endobronchial Ultrasound Scope: A Human Ex Vivo Lung Study.

    PubMed

    Patel, Priya; Wada, Hironobu; Hu, Hsin-Pei; Hirohashi, Kentaro; Kato, Tatsuya; Ujiie, Hideki; Ahn, Jin Young; Lee, Daiyoon; Geddie, William; Yasufuku, Kazuhiro

    2017-04-01

    Endobronchial ultrasonography (EBUS)-guided transbronchial needle aspiration allows for sampling of mediastinal lymph nodes. The external diameter, rigidity, and angulation of the convex probe EBUS renders limited accessibility. This study compares the accessibility and transbronchial needle aspiration capability of the prototype thin convex probe EBUS against the convex probe EBUS in human ex vivo lungs rejected for transplant. The prototype thin convex probe EBUS (BF-Y0055; Olympus, Tokyo, Japan) with a thinner tip (5.9 mm), greater upward angle (170 degrees), and decreased forward oblique direction of view (20 degrees) was compared with the current convex probe EBUS (6.9-mm tip, 120 degrees, and 35 degrees, respectively). Accessibility and transbronchial needle aspiration capability was assessed in ex vivo human lungs declined for lung transplant. The distance of maximum reach and sustainable endoscopic limit were measured. Transbronchial needle aspiration capability was assessed using the prototype 25G aspiration needle in segmental lymph nodes. In all evaluated lungs (n = 5), the thin convex probe EBUS demonstrated greater reach and a higher success rate, averaging 22.1 mm greater maximum reach and 10.3 mm further endoscopic visibility range than convex probe EBUS, and could assess selectively almost all segmental bronchi (98% right, 91% left), demonstrating nearly twice the accessibility as the convex probe EBUS (48% right, 47% left). The prototype successfully enabled cytologic assessment of subsegmental lymph nodes with adequate quality using the dedicated 25G aspiration needle. Thin convex probe EBUS has greater accessibility to peripheral airways in human lungs and is capable of sampling segmental lymph nodes using the aspiration needle. That will allow for more precise assessment of N1 nodes and, possibly, intrapulmonary lesions normally inaccessible to the conventional convex probe EBUS. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection.

    PubMed

    Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi

    2008-01-01

    Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  11. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection

    PubMed Central

    Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi

    2008-01-01

    Background and aims Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Materials and methods Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. Results 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). Conclusion According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance. PMID:23285329

  12. [On-site fine-needle aspiration cytology of thyroid nodules. Quality assurance of the Bethesda System for Reporting Thyroid Cytopathology (2008)].

    PubMed

    Bak, Mihály; Péter, Ilona; Nyári, Tibor; Simon, Péter; Újlaky, Mátyás; Boér, András; Kásler, Miklós

    2015-10-11

    The methods available for the diagnosis of thyroid nodules include physical examination, imaging, laboratory and fine-needle aspiration cytology tests. The aim of this study was to determine the quality assurance of fine-needle aspiration cytology of thyroid nodules. Cytology results were rated to 6 categories according to the Bethesda System for Reporting Thyroid Cytopathology (2008) (I. nondiagnostic; II. benign; III. atypia of undetermined significance; IV. follicular neoplasia; V. suspicious for malignancy; VI. malignant). All cytology reports were compared with the final histology diagnosis. A total of 1384 patient with thyroid nodule underwent fine-needle aspiration biopsy cytology. Smears were classified I. inadequate in 214 (15.9%); II. benign 986; III. atypical 56; IV. follicular neoplasm 41; V. suspicious for malignancy 18; VI. malignant 33 cases. Two hundred and twenty seven (16.8%) of the cases were operated and histologically verified. The positive predictive value in the benign category was 98.25% and in the malignant 88.46%. The sensitivity of the follicular neoplasm was 66.67%. The results suggest that fine-needle aspiration cytology of thyroid nodules using the Bethesda System for Reporting Thyroid Cytopathology has a high diagnostic accuracy. The auditing values of the results meet the proposed threshold values.

  13. Chest tube drainage versus needle aspiration for primary spontaneous pneumothorax: which is better?

    PubMed Central

    Wang, Chengdi; Lyu, Mengyuan; Zhou, Jian; Liu, Yang

    2017-01-01

    Background Needle aspiration and chest tube drainages are two main treatments for primary spontaneous pneumothorax (PSP). However, the application of needle aspiration or chest tube drainages has not reached a consensus. The aim of this study is to compare the needle aspiration with chest tube drainages in patients suffering with PSP and therefore help offer suggestions for clinical practice. Methods We searched literatures from PubMed, OVID and Web of Science from their inception to June 30, 2017. Continuous and dichotomous outcomes were expressed by weight mean difference (WMD) and risk ratio (RR) respectively, and each with 95% confidence intervals (CIs). We used the fixed effect or random effect model to perform quantitative synthesis. Results A total of 6 RCTs recruiting 458 participants were included in our analysis. On the basis of the six studies, our results indicated that compared with chest tube drainage applying needle aspiration shortened the hospital stay (WMD: ‒1.67 days; 95% CI: ‒2.25 to 1.08; P<0.001) and decreased hospitalization rate (RR: 0.40; 95% CI: 0.22–0.75; P=0.004). However, there was no difference regarding immediate success rate (RR: 1.01; 95% CI: 0.70–1.46; P=0.96) and one-year recurrence rate (RR: 0.89; 95% CI: 0.58–1.38; P=0.61). Conclusions In the light of this present research, it is necessary to apply needle aspiration into treating PSP to reduce hospitalization rate and shorten hospital stay. However, the two treatments have no significant difference with respect to immediate success rate, one-year recurrence rate, one-week success rate, three-month recurrence rate or complication rate. PMID:29268413

  14. Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?

    PubMed

    Karadsheh, Zeid; Al-Haddad, Mohammad

    2014-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is increasingly used as a diagnostic and therapeutic tool for pancreatic and other gastrointestinal disorders. Several factors affect the outcome of EUS-FNA, one of which is needle size. The decision to use a specific needle depends on factors including location, consistency, and type of the lesion; presence of onsite cytopathologist; and need for additional tissue procurement for histology. This review provides a balanced perspective on the use of different needle sizes available, highlighting the differences among them and potential niche applications of each to maximize diagnostic yield of EUS-FNA. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. The cost-effectiveness of iodine 131 scintigraphy, ultrasonography, and fine-needle aspiration biopsy in the initial diagnosis of solitary thyroid nodules.

    PubMed

    Khalid, Ayesha N; Hollenbeak, Christopher S; Quraishi, Sadeq A; Fan, Chris Y; Stack, Brendan C

    2006-03-01

    To compare the cost-effectiveness of fine-needle aspiration biopsy, iodine 131 scintigraphy, and ultrasonography for the initial diagnostic workup of a solitary palpable thyroid nodule. A deterministic cost-effectiveness analysis was conducted using a decision tree to model the diagnostic strategies. A single, mid-Atlantic academic medical center. Expected costs, expected number of cases correctly diagnosed, and incremental cost per additional case correctly diagnosed. Relative to the routine use of fine-needle aspiration biopsy, the incremental cost per case correctly diagnosed is 24,554 dollars for the iodine 131 scintigraphy strategy and 1212 dollars for the ultrasound strategy. A diagnostic strategy using initial fine-needle aspiration biopsy for palpable thyroid nodules was found to be cost-effective compared with the other approaches as long as a payor's willingness to pay for an additional correct diagnosis is less than 1212 dollars. Prospective studies are needed to validate these finding in clinical practice.

  16. Ultrasound-guided fine-needle aspiration biopsy of clinically suspicious thyroid nodules with an automatic aspirator: a novel technique.

    PubMed

    Nagarajah, James; Sheu-Grabellus, Sien-Yi; Farahati, Jamshid; Kamruddin, Kamer A; Bockisch, Andreas; Schmid, Kurt Werner; Görges, Rainer

    2012-07-01

    Fine-needle aspiration biopsy (FNAB) is a simple technique for the investigation of suspicious thyroid nodules. However, low success rates are reported in the literature. The aim of this prospective study was to compare the clinical performance and impact of an automatic aspirator, referred to here as Aspirator 3, to those of the manual technique for the FNAB of clinically suspicious thyroid nodules. One hundred nine consecutive patients with 121 clinically suspicious thyroid nodules underwent a biopsy twice of the same site with the clinically approved Aspirator 3 and with the manual technique. The number of follicular cell formations and the total number of follicular cells in the aspirate were counted using the ThinPrep® method. With the Aspirator 3, the total number and the mean number of extracted cell formations were significantly higher than the values achieved with the manual technique (total: 3222 vs. 1951, p=0.02; mean: 27 vs. 16). The total number of cells that were biopsied was also higher when the Aspirator 3 was utilized (47,480 vs. 23,080, p=0.005). Overall, the Aspirator 3 was superior in 65 biopsies, and the manual technique was superior in 39 biopsies. In terms of cell formations and the total number of cells aspirated, the Aspirator 3 was superior to the manual technique. Further, the Aspirator 3 was more convenient to use and had a greater precision in needle guidance.

  17. Double-pointed 30-gauge needle for keratocentesis.

    PubMed

    Angi, M R; Endara, N I

    1985-12-01

    A new, efficient instrument for performing keratocentesis for aqueous humour aspiration and anterior chamber microinfusion is described. It consists of a double-pointed 30-gauge needle, a liquid container (a nonflexible vinyl tube plugged at one end with a rubber stopper) and a aspiration-infusion syringe connected to the container and needle by a flexible vinyl tube. The instrument's advantages are a safer technique, complete collection of the aqueous humour and better handling of the sample.

  18. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system.

    PubMed

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology.

  19. Fine-needle aspiration by vacuum tubes.

    PubMed

    Holmquist, N D

    1989-07-01

    Fine-needle aspiration of subcutaneous masses, accepted in many parts of Europe and the Americas as a routine diagnostic technique, employs a syringe holder to facilitate the creation of a vacuum to withdraw cells. This investigation demonstrates that a vacuum tube used in venipuncture can be used to supply the negative pressure to suck cells into the needle. This apparatus is more readily available than a syringe holder in hospitals and clinics, and particularly provides the operator with a more dexterous approach to the mass because the fingers holding the needle can be much closer to the mass being immobilized by the other hand.

  20. Reverse transcriptase polymerase chain reaction on fine needle aspirates for rapid detection of translocations in synovial sarcoma.

    PubMed

    Nilsson, G; Wang, M; Wejde, J; Kanter, L; Karlén, J; Tani, E; Kreicbergs, A; Larsson, O

    1998-01-01

    To evaluate the utilization of fine needle aspiration (FNA) biopsy to obtain material for reverse-transcriptase polymerase chain reaction (RT-PCR) in the detection of the t(X;18)(p11.2;q11.2) translocation in synovial sarcomas. We applied RT-PCR to detection of synovial sarcoma fusion gene transcripts on fine needle aspirates. Five clinical samples were first analyzed: one was a tumor previously diagnosed as malignant hemangiopericytoma, one was a poorly defined tumor, and three were suspected synovial sarcomas. FNA material was transferred directly to the RT-PCR reaction tube without RNA extraction. The t(X;18) translocation could be detected on the limited amount of material that FNA provides. In each of the cases studied the representivity of the tumor samples was confirmed microscopically. Our protocol permits analysis directly on representative samples without extraction of RNA. The results imply that RT-PCR offers reliable detection of sarcoma fusion gene transcripts on fine needle aspirates. The procedure, apart from being applicable to outpatients, is rapid and sensitive.

  1. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  2. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy.

    PubMed

    Naqvi, Hanna; Edhi, Muhammad Muzzammil; Aslam, Hafiz Muhammad; Faridi, Naveen

    2013-02-12

    Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis.

  3. Nonpalpable breast tumors: diagnosis with stereotaxic localization and fine-needle aspiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowlatshahi, K.; Gent, H.J.; Schmidt, R.

    1989-02-01

    Modern mammography is the most effective means of detecting nonpalpable breast cancers, but correct diagnosis for malignancy is made in only 20%-30% of the cases. The conventional method of lesion localization usually results in approximate placement of the hookwire in the breast. The authors report the results of stereotaxic localization, combined with fine-needle aspiration and cytologic study, performed in 528 cases. Clinically occult breast lesions were localized precisely (within 2 mm 96% of the time), sampled by means of a 23-gauge needle, and marked with either methylene blue or a hookwire for subsequent open excisional biopsy. The results indicate amore » sensitivity of 95%, specificity of 91%, and accuracy of 92% for the fine-needle aspiration procedure. This technique offers a significantly improved preoperative method of diagnosing small breast lesions with minimal pain, no complications, reduced cost, and no disfigurement or scar interfering with subsequent mammographic follow-up.« less

  4. Fine needle aspiration cytology in the management of head and neck masses.

    PubMed

    Slack, R W; Croft, C B; Crome, L P

    1985-04-01

    Fine needle aspiration cytology is a useful technique in the management of patients with masses in the head and neck, which is usually performed in co-operation with a specialized cytopathologist. It has not until recently been an investigation used frequently by British otolaryngologists. This study shows that an aspiration cytology service may be run with the aid of a general histopathologist and demonstrates that it is a valuable aid to diagnosis even without the services of a specialized cytopathologist.

  5. Percutaneous CT-Guided Biopsy of the Lung: Comparison Between Aspiration and Automated Cutting Needles Using a Coaxial Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurent, Francois; Latrabe, Valerie; Vergier, Beatrice

    2000-07-15

    Purpose: To compare the accuracy and complication rate of two different CT-guided transthoracic needle biopsy techniques: fine needle aspiration and an automated biopsy device.Methods: Two consecutive series of respectively 125 (group A) and 98 (group B) biopsies performed using 20-22 gauge coaxial fine needle aspiration (group A) and an automated 19.5 gauge coaxial biopsy device (group B) were compared in terms of their accuracy and complication rate.Results: Groups A and B included respectively 100 (80%) and 77 (79%) malignant lesions and 25 (20%) and 18 (21%) benign lesions. No significant difference was found between the two series concerning patients, lesions,more » and procedural variables. For a diagnosis of malignancy, a statistically significant difference in sensitivity was found (82.7% vs 97.4%) between results obtained with the automated biopsy device and fine needle aspiration respectively. For a diagnosis of malignancy, the false negative rate of the biopsy result was significantly higher (p <0.005) in group A (17%) than in group B (2.6%). For a specific diagnosis of benignity, no statistically significant difference was found between the two groups (44% vs 26%) but the automated biopsy device provided fewer indeterminate cases. There was no difference between the two groups concerning the pneumothorax rate, which was 20% in group A and 15% in group B, or the hemoptysis rate, which was 2.4% in group A and 4% in group B.Conclusion: For a diagnosis of malignancy when a cytopathologist is not available on-site, automated biopsy devices provide a lower rate of false negative results and a similar complication rate to fine needle aspiration.« less

  6. Role of bronchoscopy in evaluation of cases with sputum smear negative pulmonary tuberculosis, interstitial lung disease and lung malignancy: A retrospective study of 712 cases.

    PubMed

    Kumar, Raj; Gupta, Nitesh

    2015-01-01

    The introduction of flexible bronchoscope has revolutionized the field of pulmonary medicine and is a standard instrument used for diagnostic purpose. A retrospective analysis of the clinico-radiological profile, indication, biopsy procedure and complications, for patients undergoing bronchoscopy at one of the respiratory unit at a tertiary care center in India. Retrospective analysis of 712 bronchoscopies was done in regard to demographic profile, clinical and radiological presentation and diagnostic indication. The results were analyzed on basis of bronchoscopy inspection and histopathological specimen obtained from transbronchial (TBLB), endobronchial biopsy (EBLB) and cytology specimen by transbronchial needle aspiration (TBNA). Furthermore, diagnostic yield of each biopsy procedure and their combination was evaluated. Of 712 patients undergoing bronchoscopy, the pathological diagnosis was achieved in 384 (53.93%). Of 384 diagnosed cases, the clinic-radio-pathological diagnosis of pulmonary tuberculosis in 88 (22.19%), interstitial lung disease (ILDs) in 226 (58.85%), and lung cancer in 70 (18.22%) cases. Of 116 sputum smear negative tuberculosis patients, 88 (75.86%) were diagnosed to be pulmonary tuberculosis; the contribution of BAL being 71.59%. Of 226 ILDs, sarcoidosis was most common 148/226 (65.48%). Among 70 lung cancer diagnosed cases, squamous cell carcinoma was most common (54.28%). The results from current study reemphasizes on the diagnostic utility as well as safety of the bronchoscopy procedure. Copyright © 2015 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  7. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system

    PubMed Central

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology PMID:26119166

  8. Core biopsy as a simple and effective diagnostic tool in head and neck focal myositis.

    PubMed

    Tan, Chun Yee; Chong, Sheldon; Shaw, Chi-Kee Leslie

    2015-12-01

    Most unilateral head and neck masses are benign, although malignancy is a possibility in some cases. However, there are other rare causes of unilateral neck masses, such as focal myositis, which is a rare, benign condition belonging to the family of inflammatory pseudotumors of the skeletal muscles, with rare presentations in the head and neck region. Focal myositis presents as a rapidly enlarging neck mass that can be misdiagnosed by fine-needle aspiration biopsy and/or radiologic imaging as either an infective or a neoplastic process. To date, there are only 5 reported cases of adult focal myositis of the sternocleidomastoid muscle in the medical literature. In this article, the authors present 2 cases involving patients with focal myositis of the sternocleidomastoid muscle that were successfully diagnosed with core-needle biopsy and managed conservatively. The pros and cons of fine-needle aspiration biopsy and core-needle biopsy are discussed. Based on the authors' results, fine-needle aspiration biopsy universally fails to provide the diagnosis of focal myositis. In contrast, core-needle biopsy successfully diagnosed focal myositis in both of our patients. Both of them had complete resolution with conservative management.

  9. Comparison of PD-L1 mRNA Expression Measured with the CheckPoint Typer® Assay with PD-L1 Protein Expression Assessed with Immunohistochemistry in Non-small Cell Lung Cancer.

    PubMed

    Erber, Ramona; Stöhr, Robert; Herlein, Stefanie; Giedl, Claudia; Rieker, Ralf Joachim; Fuchs, Florian; Ficker, Joachim H; Hartmann, Arndt; Veltrup, Elke; Wirtz, Ralph M; Brueckl, Wolfgang M

    2017-12-01

    Immunohistochemical (IHC) assessment of programmed death-ligand 1 (PD-L1) in non-small cell lung cancer (NSCLC) has become important since the development of anti-PD-1/-PD-L1 directed drugs. Various PD-L1 antibodies and cut-offs have been used in different trials to predict response to these drugs, thus comparison of those studies is difficult. We compared PD-L1 mRNA expression measured by RT-qPCR with PD-L1 protein expression evaluated by IHC. Moreover, we investigated the impact of different tumour tissue acquisition methods on the reliability of PD-L1 measurement techniques. NSCLC cases (N=22), including n=9 mediastinal lymph node biopsies acquired by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and n=5 metastases, were evaluated prospectively for PD-L1 protein on tumor cells (TC) and immune cells (IC) using E1L3N and 28-8 antibodies and PD-L1 mRNA using the CheckPoint TYPER® assay. In primary NSCLC tissues, agreement between PD-L1 mRNA and TC staining using the 28-8 antibody was excellent (ĸ=0.85, p=0.0002). Comparing both PD-L1 antibodies against each other showed a kappa value of 0.58 (p=0.0106). In EBUS-TBNA, PD-L1 mRNA correlated perfectly with the 28-8 antibody (ĸ=1.0, p=0.0023). PD-L1 mRNA levels significantly differed when comparing 28-8 TC staining of tumours >49% with 1-49% and 0% (p=0.0040; p=0.0081, respectively). In metastatic lesions, differences between PD-L1 mRNA and IHC became apparent (ĸ=0.2, p=0.2525). Testing of PD-L1 mRNA and 28-8 IHC showed an excellent agreement in NSCLC samples including mediastinal lymph node biopsies. Since PD-L1 expression in >50% TC detected by 28-8 IHC can be reliably detected by RT-qPCR, quantitative PD-L1 mRNA determination should be considered as an alternative to IHC as there is no interobserver variability in RNA results. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  10. Physician control of needle and syringe during aspiration-injection procedures with the new reciprocating syringe.

    PubMed

    Sibbitt, Wilmer; Sibbitt, Randy R; Michael, Adrian A; Fu, Druce I; Draeger, Hilda T; Twining, Jon M; Bankhurst, Arthur D

    2006-04-01

    To evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe. Twenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures. In the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001). The reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.

  11. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy

    PubMed Central

    2013-01-01

    Background Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. Methodology It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. Results A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). Conclusion CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis. PMID:23402220

  12. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  13. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    PubMed Central

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer. PMID:24212643

  14. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses

    PubMed Central

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-01-01

    Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394

  15. Fine-needle aspiration cytology of mucous retention cyst of the tongue: distinction from other cystic lesions of the tongue.

    PubMed

    De Las Casas, L E; Bardales, R H

    2000-05-01

    Mucous retention cyst (MRC) is a common submucosal lesion of the oral cavity that, when deeply seated, simulates a neoplasm. This report describes the fine-needle aspiration cytology findings of a lingual MRC of complex architecture and with metaplastic epithelium. In addition, we emphasize its cytologic differential diagnosis from other benign and malignant cystic lesions of the tongue. To the best of our knowledge, this is the first report of aspiration cytology of a complex MRC of the tongue. Copyright 2000 Wiley-Liss, Inc.

  16. Randomized, open trial comparing a modified double-lumen needle follicular flushing system with a single-lumen aspiration needle in IVF patients with poor ovarian response.

    PubMed

    von Horn, Kyra; Depenbusch, Marion; Schultze-Mosgau, Askan; Griesinger, Georg

    2017-04-01

    Is a modified double-lumen aspiration needle system with follicular flushing able to increase the mean oocyte yield by at least one in poor response IVF patients as compared to single-lumen needle aspiration without flushing? Follicular flushing with the modified flushing system did not increase the number of oocytes, but increased the procedure duration. Most studies on follicular flushing were performed with conventional double-lumen needles in patients who were normal responders. Overall, these studies indicated no benefit of follicular flushing. Prospective, single-centre, randomized, controlled, open, superiority trial comparing the 17 G Steiner-Tan Needle® flushing system with a standard 17 G single-lumen aspiration needle (Gynetics®); time frame February 2015-March 2016. Eighty IVF patients, 18-45 years, BMI >18 kg/m2 to <35 kg/m2, presenting with ≤ five follicles >10 mm in both ovaries at the end of the follicular phase were randomized to either aspirating and flushing each follicle 3× with the Steiner-Tan-Needle® automated flushing system (n = 40) or a conventional single-lumen needle aspiration (n = 40). Primary outcome was the number of cumulus-oocyte-complexes (COCs). Procedure duration, burden (Depression Anxiety and Stress Scale; DASS-21) and post-procedure pain were also assessed. Flushing was not superior with a mean (SD) number of COCs of 2.4 (2.0) and 3.1 (2.3) in the Steiner-Tan Needle® and in the Gynectics® group, respectively (mean difference -0.7, 95% CI: 0.3 to -1.6; P = 0.27). Likewise no differences were observed in metaphase II  oocytes, two pronuclear oocytes, number of patients having an embryo transfer and DASS 21 scores. The procedure duration was significantly 2-fold increased. Testing for differences in the number of patients achieving an embryo transfer or differences in pregnancy rate would require a much larger sample size. The use of follicular flushing is unlikely to benefit the prognosis of patients with poor ovarian response. The Steiner-Tan Needles® and the flushing system were provided for free by the manufacturer. K.v.H. has received personal fees from Finox and non-financial support from Merck-Serono; M.D. has received personal fees from Finox and non-financial support from Merck-Serono. A.S.-M. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA. G.G. has received personal fees and non-financial support from M.D., Ferring, Merck-Serono, Finox, TEVA, IBSA, Glycotope, as well as personal fees from VitroLife, NMC Healthcare LLC, ReprodWissen LLC and ZIVA LLC. NCT 02365350 (clinicaltrials.gov). Sixth of February 2015. Ninth of February 2015. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. Aspiration of breast abscess under ultrasound guidance: outcome obtained and factors affecting success.

    PubMed

    Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan

    2007-01-01

    To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.

  18. Role of fine needle aspiration cytology in diagnosing filarial arm cysts.

    PubMed

    Tandon, Nishi; Bansal, Cherry; Sharma, Richa; Irfan, Sumaiya

    2013-05-17

    Filariasis is prevalent in tropical and subtropical areas and is endemic in regions of India. Lymphatic filariasis in India is caused mainly by two species of nematodes: Wuchereria bancrofti and Brugia malayi, which invade the human lymphatic system. We report two cases of superficial cystic lesions of the upper limb revealed on fine needle aspiration (FNA) to be clinically unsuspected filariasis. Despite similar aetiologies, both cases revealed variations in aspirate nature, smear morphology and peripheral blood findings. FNA provides definitive diagnosis and is an important tool for diagnosing soft tissue swellings owing to filariasis.

  19. Ultrasonography and fine needle aspirate cytology of the mesenteric lymph node in normal domestic ferrets (Mustela putorius furo).

    PubMed

    Paul-Murphy, J; O'Brien, R T; Spaeth, A; Sullivan, L; Dubielzig, R R

    1999-01-01

    The large mesenteric lymph node of 28 normal ferrets was imaged with ultrasound. The large node, located in the mid-abdomen at the root of the mesentery, was round to ovoid and uniformly hyperechoic. Mean ultrasonographic dimensions of the lymph node were 12.6 +/- 2.6 mm by 7.6 +/- 2.0 mm. Fine needle aspirates of 20 lymph nodes were obtained either using ultrasound guided free-hand techniques or at necropsy. The cytological descriptions were compared to histological descriptions of 13 lymph node core biopsies obtained during laparotomy or necropsy as well as 10 peripheral blood smear differentials. The large mesenteric lymph node of ferrets could be easily imaged and measured by ultrasound and evaluated by fine needle aspirate cytology. Normal lymph node cytology may include an eosinophilic infiltrate.

  20. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems.

    PubMed

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA", which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%" on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples.

  1. Do acute-care surgeons follow best practices for breast abscess management? A single-institution analysis of 325 consecutive cases.

    PubMed

    Barron, Alison Unzeitig; Luk, Stephen; Phelan, Herb A; Williams, Brian H

    2017-08-01

    The breast surgery community has adopted needle aspiration as the standard of care for breast abscesses, which have a size less than 5 cm on ultrasound, no skin changes, and fewer than 5 days of symptoms. Our acute-care surgery (ACS) service manages all breast abscess consults at our urban safety-net hospital. We undertook this descriptive study to identify the rate of operative incisions and drainage performed by ACS surgeons which were not compatible with best practices for breast abscess management. We performed a retrospective review of the electronic health records of all patients on whom the ACS service was consulted for a breast abscess at our urban safety-net hospital between January 2010 and December 2014. We collected data on patient demographics, breast skin characteristics, length of symptoms, ultrasound results, and treatment modality. A total of 325 patients with breast abscesses were evaluated by ACS, of whom 21 met the breast community's indications for needle aspiration. Of the overall 325 subject sample, 281 (86.5%) underwent incision and drainage (I&D), and 44 (13.5%) underwent bedside needle aspiration. Of the 281 patients that underwent I&D, 269 (95.7%) met the breast surgery community's indications for I&D due to either skin changes (n = 90, 33.5%), abscess >5 cm on ultrasound (n = 88, 32.7%), or symptoms >5 days (n = 238, 88.5%). Of the 44 patients that underwent needle aspiration, only 9 (20.5%) met the current practice indications for aspiration. Of the 44 patients that underwent aspiration, 28 (63.6%) failed and went on to have an operation. The majority of these failed aspirations had symptoms >5 days (23 patients, 82.1%) or had skin changes at presentation (1 patient, 3.6%) or an abscess >5 cm on ultrasound (5 patients, 17.9%). As judged by best practices promulgated by the breast surgery community, ACS surgeons do not show excessive rates of operative I&D of breast abscess and in fact seem to overutilize needle aspiration. To our knowledge, this is the largest single institution series of the management of breast abscesses by ACS surgeons in the literature. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Highly controlled vascular syringes for pericardiocentesis.

    PubMed

    Ricciardi, Mark; Roldan, Carlos; Sibbitt, Randy; Sibbitt, Wilmer; Michael, Adrian; Palmer, Dennis

    2010-12-01

    The present study determined the utility and needle control characteristics of highly controlled vascular syringes for image-guided pericardiocentesis. Vascular syringes have been integrated into invasive cardiovascular procedures with improved patient safety, but to date have not been used in pericardiocentesis. To address this issue, we determined the method of use of vascular syringes for pericardiocentesis. A vascular syringe with reciprocating plungers, the reciprocating procedure device (RPD syringe), replaced the corresponding 10 ml and 20 ml conventional syringes in a standard pericardiocentesis tray. The vascular syringe is controlled with one hand, and can either aspirate or inject by pushing the corresponding aspiration or injection plunger. Four hundred and thirty seven subjects underwent vascular syringe procedures. The linear displacement method was used to precisely measure control of the needle tip in millimeters (mm) in vascular syringes compared to conventional syringes in 20 individual operators. Relative to the corresponding 10 ml and 20 ml conventional syringes, vascular syringes significantly reduced unintended forward penetration of the needle tip by 44% (7.0 ± 4.3 mm; p < 0.0001) and 53% (10.1 ± 5.5 mm; p < 0.0001), respectively, and reduced unintended retraction of the needle by 56% (2.7 ± 2.2 mm; p < 0.001) and 60% (3.5 ± 2.5 mm; p < 0.001), respectively. During pericardiocentesis, the mechanical syringe permitted facile one-handed aspiration and maintained the operator's ability to clear the needle. In the 437 vascular syringe procedures, there were no complications, with an estimated cost savings of $10-65 per procedure. Vascular syringes improve needle control in pericardiocentesis, promote patient safety and permit one-handed aspiration and injection.

  3. Aspiration and methylprednisolone injection to the cavity with IV cannula needle in the treatment of volar wrist ganglia: New technique

    PubMed Central

    Korkmaz, Murat; Ozturk, Hayati; Amanvermez Senarslan, Dilsad; Erdogan, Yalcin

    2013-01-01

    Objective: There are several types of treatment modalities for wrist ganglions. The aim of the study was to assess the effectiveness of cyst aspiration and methyl prednisolone acetate injection with double IV cannula rather than sharp pointed needle, as a new technique in the treatment of volar ganglia. Methodology: The study involves total of 19 patients who received treatment by aspiration and methyl prednisolone injection into the cavity. Two IV cannulas are pricked to the cystic cavity. Cyst fluid is drained by the distally placed IV cannula meanwhile injecting methyl prednisolone by proximally placed IV cannula. The patient records and follow-up reports are retrospectively investigated. The patient age, sex, site of the cyst, the treatment that was applied, adjacency to the artery and the nerves and recurrence are recorded. Mean follow up time was 2.1±0.5 years. Results: The study involved 19 patients that received aspiration treatment for volar ganglion cysts between January 2004 and December 2009. There were 12 (63.2%) female and 7 (36.8%) male subject with volar wrist ganglion cyst. The mean age of patients was 27.63±6.6 years. Fourteen (73.7%) patients of total had cysts close to the artery. We didn’t observe any complication related to methyl prednisolone injection and arterial ischemia. Recurrence was observed in three (15.8%) patients. Conclusion: This method has lower recurrence rate than other aspiration therapy with sharp pointed needle. We prefer to use IV cannula needle for cyst aspiration and steroid injection in treatment of volar ganglia before any surgical intervention. PMID:24353517

  4. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    PubMed

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  5. Extramedullary plasmacytoma. Fine needle aspiration findings.

    PubMed

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  6. Papular skin lesions: Clue to a recurrence of breast cancer on fine needle non-aspiration cytology (FNNAC)

    PubMed Central

    Afrose, Ruquiya; Akram, Mohammad; Siddiqui, Shahid Ali

    2015-01-01

    Cutaneous metastasis from underlying carcinoma is relatively uncommon in clinical practice. A high index of suspicion is required to diagnose these lesions, as these lesions can mimic benign skin lesions and clinical findings may be subtle. Fine needle aspiration cytology (FNAC) is commonly employed for diagnosing these skin lesions. However, it is often difficult to aspirate adequate material from small papular lesions. In these clinical situations, fine needle non-aspiration cytology (FNNAC) is proposed as an alternative procedure. FNNAC eliminates the negative suction pressure employed in FNAC and decreases the dilution of tumor cells by blood and hence yields adequate diagnostic material. We report here a case in which FNNAC was used in place of FNAC in diagnosing papular skin lesions. This procedure was carried out in a treated patient of carcinoma breast who was on regular follow-up and presented to us with a 20-day history of papular skin lesions over the chest and back. This article enlightens the clinicians about the utility of FNNAC, which is a relatively uncommon procedure. PMID:25948954

  7. Papular skin lesions: Clue to a recurrence of breast cancer on fine needle non-aspiration cytology (FNNAC).

    PubMed

    Afrose, Ruquiya; Akram, Mohammad; Siddiqui, Shahid Ali

    2015-01-01

    Cutaneous metastasis from underlying carcinoma is relatively uncommon in clinical practice. A high index of suspicion is required to diagnose these lesions, as these lesions can mimic benign skin lesions and clinical findings may be subtle. Fine needle aspiration cytology (FNAC) is commonly employed for diagnosing these skin lesions. However, it is often difficult to aspirate adequate material from small papular lesions. In these clinical situations, fine needle non-aspiration cytology (FNNAC) is proposed as an alternative procedure. FNNAC eliminates the negative suction pressure employed in FNAC and decreases the dilution of tumor cells by blood and hence yields adequate diagnostic material. We report here a case in which FNNAC was used in place of FNAC in diagnosing papular skin lesions. This procedure was carried out in a treated patient of carcinoma breast who was on regular follow-up and presented to us with a 20-day history of papular skin lesions over the chest and back. This article enlightens the clinicians about the utility of FNNAC, which is a relatively uncommon procedure.

  8. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    PubMed

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  9. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases.

    PubMed

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-12-14

    To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients ( P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group ( P < 0.05). Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration.

  10. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    PubMed

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  11. Use of fine needle aspirate from peripheral nerves of pure-neural leprosy for cytology and PCR to confirm the diagnosis: a pilot study.

    PubMed

    Reja, Abu Hena Hasanoor; De, Abhishek; Biswas, Supratik; Chattopadhyay, Amitabha; Chatterjee, Gobinda; Bhattacharya, Basudev; Sarda, Aarti; Aggarwal, Ishad

    2013-01-01

    The diagnosis of pure neural leprosy (PNL) remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC) coupled with Ziehl Neelsen staining (ZN staining) and Multiplex-Polymerase Chain Reaction (PCR) specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL), which may be simpler and yet reliable. The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex-PCR. Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4%) with the help of conventional acid-fast staining and 11 cases (84.6%) with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23%) cases showed specific epithelioid cells, whereas 8 (61.5%) cases showed non-specific inflammation, and 2 (15.3%) cases had no inflammatory cells. Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB) and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of PNL.

  12. [Quality assurance of fine-needle aspiration cytology of the organized mammography screening].

    PubMed

    Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós

    2010-08-08

    The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (p<0.001). The auditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.

  13. Ultrasound-guided fine-needle aspiration of a posterior neck dedifferentiated liposarcoma with MDM2 fluorescence in situ hybridization performed on a Pap-stained smear.

    PubMed

    Zreik, Riyam; Soyalp, Krystal; Ruiz, Steve; Ward, Russell; Dobin, Sheila; Chen, Xiangbai; Liu, Lina; Rao, Arundhati

    2015-04-01

    Head and neck liposarcomas, while rare, tend to be subcutaneous and well-differentiated. Dedifferentiated liposarcomas of the head and neck are exceedingly rare in the literature. We present a case of a dedifferentiated liposarcoma arising in the soft tissue of the posterior neck of an 86-year-old man and diagnosed by fine-needle aspiration. Aspirate smears showed a dual population of atypical lipomatous and spindled cells. MDM2 (murine double minute 2) amplification was demonstrated on a Pap-stained smear using fluorescence in situ hybridization (FISH). To the best of our knowledge, this is the first report of MDM2 FISH amplification in a liposarcoma performed on an aspirate smear. © 2014 Wiley Periodicals, Inc.

  14. Aspiration and Biopsy: Bone Marrow

    MedlinePlus

    ... Print What It Is Bone marrow aspirations and biopsies are performed to examine bone marrow, the spongy liquid part of the bone where blood cells are ... you might also feel the pressure of the biopsy needle pushing in. Some ... sharp cramp as the liquid bone marrow is withdrawn for the aspiration or ...

  15. Treatments for breast abscesses in breastfeeding women.

    PubMed

    Irusen, Hayley; Rohwer, Anke C; Steyn, D Wilhelm; Young, Taryn

    2015-08-17

    The benefits of breastfeeding are well known, and the World Health Organization recommends exclusive breastfeeding for the first six months of life and continuing breastfeeding to age two. However, many women stop breastfeeding due to lactational breast abscesses. A breast abscess is a localised accumulation of infected fluid in breast tissue. Abscesses are commonly treated with antibiotics, incision and drainage (I&D) or ultrasound-guided needle aspiration, but there is no consensus on the optimal treatment. To assess the effects of different treatments for the management of breast abscesses in breastfeeding women. We searched the Cochrane Pregnancy and Childbirth Group's Trial Register (27 February 2015). In addition we searched African Journals Online (27 February 2015), Google Scholar (27 February 2015), ProQuest Dissertations and Theses Databases (27 February 2015) and the WHO International Clinical Trials Registry Platform (ICTRP) search portal (27 February 2015). We also checked reference lists of retrieved studies and contacted experts in the field as well as relevant pharmaceutical companies. Randomised controlled trials (RCTs) investigating any intervention for treating lactational breast abscesses compared with any other intervention. Studies published in abstract form, quasi-RCTs and cluster-RCTs were not eligible for inclusion. Two review authors independently assessed studies for inclusion, assessed risk of bias and extracted data. Data were checked for accuracy. We included six studies. Overall, trials had an unclear risk of bias for most domains due to poor reporting. Two studies did not stratify data for lactational and non-lactational breast abscesses, and these studies do not contribute to the results. This review is based on data from four studies involving 325 women. Needle aspiration (with and without ultrasound guidance) versus incision and drainage (I&D) Mean time (days) to complete resolution of breast abscess (three studies) - there was substantial heterogeneity among these data (Tau(2) = 47.63, I(2) = 97%) and a clear difference between subgroups (with or without ultrasound guidance; Chi(2) = 56.88, I(2) = 98.2%, P = < 0.00001). We did not pool these data in a meta-analysis. Two studies excluded women who had treatment failure when they calculated the mean time to complete resolution. One study found that the time to complete resolution of breast abscess favoured needle aspiration over I&D (mean difference (MD) -6.07; 95% confidence interval (CI) -7.81 to -4.33; n = 36), but excluded 9/22 (41%) women in the needle aspiration group due to treatment failure. Another study reported faster resolution in the needle aspiration group (MD -17.80; 95% CI -21.27 to -14.33; n = 64) but excluded 6/35 (17%) women in the needle aspiration group due to treatment failure. A third study also reported that needle aspiration was associated with a shorter time to complete resolution of breast abscess (MD -16.00; 95%CI -18.73 to -13.27; n = 60); however, the authors did not indicate the number of women who were lost to follow-up for either group, and it is unclear how many women contributed to this result. Considering the limitations of the available data, we do not consider the results to be informative. Continuation of breastfeeding, after treatment (success): results favoured the needle aspiration group, but we did not pool data from the two studies because of substantial unexplained heterogeneity (I(2) = 97%). One study reported that women in the needle aspiration group were more likely to continue breastfeeding (risk ratio (RR) 2.89; 95% CI 1.64 to 5.08; n = 60), whereas the other study found no clear difference (RR 1.09; 95% CI 0.97 to 1.22 n = 70). Treatment failure was more common among women treated with needle aspiration compared to those who underwent I&D (RR 16.12; 95% CI 2.21 to 117.73; two studies, n = 115, low quality evidence). In one study, treatment with needle aspiration failed in 9/22 women who subsequently underwent I&D to treat their breast abscess. In another study, treatment with needle aspiration failed in 6/35 women, who subsequently underwent I&D. All abscesses in the I&D group were successfully treated.The included studies provided limited data for the review's secondary outcomes. No data were reported for adverse events. One study (60 women) reported that women in the needle aspiration group were more satisfied with their treatment than women who received I&D to treat their breast abscesses. Incision and drainage (I&D) with or without antibioticsOne study (150 women) compared the value of adding a broad-spectrum cephalosporin (single dose or a course of treatment) to women who underwent I&D for breast abscesses.The mean time to resolution of breast abscess was reported as being similar in all groups (although women with infection were excluded). Mean time to resolution for women who received a course of antibiotics was reported as 7.3 days, 6.9 days for women who received a single dose of antibiotics and 7.4 days for women who did not receive antibiotics. Standard deviations, P values and CIs were not reported and prevented further analysis. No data were reported for any continuation of breastfeeding after treatment (success). For treatment failure, there was no clear difference between the groups of women who received antibiotics (either a single dose or a course of antibiotics) and those who did not (RR 1.00; 95% CI 0.36 to 2.76).Included studies rarely reported this review's secondary outcomes (including adverse events). For post-operative complications/morbidity, there was no difference in the risk of wound infections between the antibiotics and no antibiotics groups (RR 0.58; 95% CI 0.29 to 1.17), irrespective of whether women received a single dose or a course of antibiotics. There is insufficient evidence to determine whether needle aspiration is a more effective option to I&D for lactational breast abscesses, or whether an antibiotic should be routinely added to women undergoing I&D for lactational breast abscesses. We graded the evidence for the primary outcome of treatment failure as low quality, with downgrading based on including small studies with few events and unclear risk of bias.

  16. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    PubMed Central

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. PMID:25352966

  17. Efficacy of aspiration in amebic liver abscess.

    PubMed

    Ghosh, Jayant Kumar; Goyal, Sundeep Kumar; Behera, Manas Kumar; Tripathi, Manish Kumar; Dixit, Vinod Kumar; Jain, Ashok Kumar; Shukla, Ramchandra

    2015-01-01

    Amebic liver abscess (ALA) is a common and serious problem in our country. There are only a few controlled trials on the efficacy and advantages of combination therapy with percutaneous needle aspiration and pharmacotherapy, over pharmacotherapy alone for amebic liver abscess. This study was conducted to compare the efficacy of two different treatment modalities i.e. drug treatment alone vs. drug treatment and aspiration of abscess cavity in patients with small (up to 5 cm) and large (5 cm to 10 cm) size ALA. This is one of the largest single center, prospective, randomized studies comparing the efficacy of aspiration in ALA. (i) Mean body temperature, liver tenderness, total leukocyte count (TLC), serum alanine aminotransferase (ALT) and liver span were significantly decreased in the aspiration group on days 8 and 15 as compared to non-aspiration group especially in large abscess (5 cm to 10 cm). (ii) Abscess cavity maximum diameter decreased significantly in aspiration group on days 8 and 15, and 1 month & 3 months in large abscess (5cm to 10 cm). (i) Needle aspiration along with metronidazole hastens clinical improvement especially in large (5 cm up to 10 cm) cavities in patients with ALA. (ii) Aspiration is safe and no major complications occurred. (iii) Hence, combination therapy should be the first choice especially in large ALA (5 cm to 10 cm).

  18. MR-guided fine needle aspiration of breast lesions: Initial experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wald, D.S.; Weinreb, J.C.; Newstead, G.

    1996-01-01

    Fine needle aspiration (FNA) is a minimally invasive procedure that is used to obtain cytologic specimens of suspicious lesions in the breast. The goal of this study was to evaluate the logistics and limitations of MR-guided FNA using a prototype breast localization coil. MR-guided FNAs were attempted on 18 lesions (detected on mammography and/or palpation) in 16 patients. Patients were prone with their compressed mediolaterally between two plates in a circularly polarized RF coil. Lesion position was determined by reference to fiducial makers that corresponded to a grid of holes placed at 5 mm intervals in compression plate. FNA wasmore » performed with a 22G non-ferromagnetic needle. FNA was successful for 11 of 18 lesions (61%). Of the seven unsuccessful cases, there were four in which the lesions were too posteriorly placed to be accessed through the compression plate by the needle. Three cases were too anteriorly placed to be effectively immobilized and, although successfully localized, were insufficiently sampled by the FNA technique. MR-guided FNA is possible using a prototype breast localization device in a select group of patients. Current coil design limits its use in performing MR-guided FNA on the most anteriorly and posteriorly placed breast lesions. Unique requirements of FNA under MR guidance as compared to needle localization and biopsy have been identified. Modifications in localization hardware and cytology aspiration needles should overcome these restrictions. 15 refs., 3 figs.« less

  19. Carcinoma in ectopic breast: a cytological diagnosis.

    PubMed

    Shukla, Shailaja; Sehgal, Shivali; Rai, Preeti; Agarwal, Kiran

    2015-01-01

    Ectopic breast carcinoma in the axillary region is rare with an incidence ranging from 0.3-6%. We report a case of infiltrating duct carcinoma in an adult female arising in aberrant breast tissue in the axilla diagnosed on fine needle aspiration cytology. There was history of recent increase in size of the lump which was otherwise present for the past 5 years. This case highlights the role fine needle aspiration cytology can play in the early diagnosis of malignant transformation of lumps.

  20. Aspergillus thyroiditis: first antemortem case diagnosed by fine-needle aspiration culture in a pediatric stem cell transplant patient.

    PubMed

    Badawy, S M; Becktell, K D; Muller, W J; Schneiderman, J

    2015-12-01

    Aspergillus thyroiditis (AT) has historically been considered a postmortem diagnosis in immunocompromised patients; most have disseminated disease. This report summarizes the clinical challenge of diagnosing AT. It also highlights the value of the early use of thyroid fine-needle aspiration culture and the need for a high index of suspicion to reach the final diagnosis before disease dissemination. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. [Lactational breast abscesses: Do we still need surgery?].

    PubMed

    Debord, M-P; Poirier, E; Delgado, H; Charlot, M; Colin, C; Raudrant, D; Golfier, F; Dupuis, O

    2016-03-01

    To show the effectiveness of ultrasound-guided puncture in the treatment of lactational breast abscess and identify its risk factors. Retrospective descriptive study at the CHU of Lyon-Sud from December 2007 to December 2013, including patients with lactational breast abscess confirmed on ultrasound and treated with antibiotics and analgesics. Realisation of ultrasound-guided needle under local anesthesia by the radiologist and washing the cavity with physiological serum. Forty patients had lactational abscesses at an average of 10 weeks post-partum. Thirty-four patients were treated by needle aspiration, of which 2 had first surgical drainage. The average size of the abscess was 41.2mm. The success rate of needle aspiration was 91.2%. No cases of recurrence were observed, however, there were 5 fistulisations. In all, 91.2% were treated on an outpatient basis. In 87.8% of cases, breastfeeding was continued on the healthy side and in 48.5% of cases on the affected side. The major risk factor for abscess was mastitis in 91.1% of cases. Ultrasound guidance of needle aspiration should be gold standard for the treatment of lactational breast abscesses to continue breastfeeding including the affected side. Copyright © 2015. Published by Elsevier Masson SAS.

  2. The comparative effectiveness of fine-needle aspiration cytology sampling policies: a simulation study.

    PubMed

    Schmidt, Robert L; Howard, Kirsten; Hall, Brian J; Layfield, Lester J

    2012-12-01

    Sample adequacy is an important aspect of overall fine-needle aspiration cytology (FNAC) performance. FNAC effectiveness is augmented by an increasing number of needle passes, but increased needle passes are associated with higher costs and greater risk of adverse events. The objective of this study was to compare the impact of several different sampling policies on FNAC effectiveness and adverse event rates using discrete event simulation. We compared 8 different sampling policies in 12 different sampling environments. All sampling policies were effective when the per-pass accuracy is high (>80%). Rapid on-site evaluation (ROSE) improves FNAC effectiveness when the per-pass adequacy rate is low. ROSE is unlikely to be cost-effective in sampling environments in which the per-pass adequacy is high. Alternative ROSE assessors (eg, cytotechnologists) may be a cost-effective alternative to pathologists when the per-pass adequacy rate is moderate (60%-80%) or when the number of needle passes is limited.

  3. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  4. Three-dimensional virtual bronchoscopy using a tablet computer to guide real-time transbronchial needle aspiration.

    PubMed

    Fiorelli, Alfonso; Raucci, Antonio; Cascone, Roberto; Reginelli, Alfonso; Di Natale, Davide; Santoriello, Carlo; Capuozzo, Antonio; Grassi, Roberto; Serra, Nicola; Polverino, Mario; Santini, Mario

    2017-04-01

    We proposed a new virtual bronchoscopy tool to improve the accuracy of traditional transbronchial needle aspiration for mediastinal staging. Chest-computed tomographic images (1 mm thickness) were reconstructed with Osirix software to produce a virtual bronchoscopic simulation. The target adenopathy was identified by measuring its distance from the carina on multiplanar reconstruction images. The static images were uploaded in iMovie Software, which produced a virtual bronchoscopic movie from the images; the movie was then transferred to a tablet computer to provide real-time guidance during a biopsy. To test the validity of our tool, we divided all consecutive patients undergoing transbronchial needle aspiration retrospectively in two groups based on whether the biopsy was guided by virtual bronchoscopy (virtual bronchoscopy group) or not (traditional group). The intergroup diagnostic yields were statistically compared. Our analysis included 53 patients in the traditional and 53 in the virtual bronchoscopy group. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the traditional group were 66.6%, 100%, 100%, 10.53% and 67.92%, respectively, and for the virtual bronchoscopy group were 84.31%, 100%, 100%, 20% and 84.91%, respectively. The sensitivity ( P  = 0.011) and diagnostic accuracy ( P  = 0.011) of sampling the paratracheal station were better for the virtual bronchoscopy group than for the traditional group; no significant differences were found for the subcarinal lymph node. Our tool is simple, economic and available in all centres. It guided in real time the needle insertion, thereby improving the accuracy of traditional transbronchial needle aspiration, especially when target lesions are located in a difficult site like the paratracheal station. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases

    PubMed Central

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-01-01

    AIM To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. METHODS Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. RESULTS There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients (P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group (P < 0.05). CONCLUSION Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration. PMID:28028373

  6. Biospecimen repositories and cytopathology.

    PubMed

    Krishnamurthy, Savitri

    2015-03-01

    Biospecimen repositories are important for the advancement of biomedical research. Literature on the potential for biobanking of fine-needle aspiration, gynecologic, and nongynecologic cytology specimens is very limited. The potential for biobanking of these specimens as valuable additional resources to surgically excised tissues appears to be excellent. The cervicovaginal specimens that can be used for biobanking include Papanicolaou-stained monolayer preparations and residual material from liquid-based cytology preparations. Different types of specimen preparations of fine-needle aspiration and nongynecologic specimens, including Papanicolaou-stained and Diff-Quik-stained smears, cell blocks. and dedicated passes/residual material from fine-needle aspiration stored frozen in a variety of solutions, can be used for biobanking. Because of several gaps in knowledge regarding the standard of operative procedures for the procurement, storage, and quality assessment of cytology specimens, further studies as well as national conferences and workshops are needed not only to create awareness but also to facilitate the use of cytopathology specimens for biobanking. © 2014 American Cancer Society.

  7. Update on Molecular Testing for Cytologically Indeterminate Thyroid Nodules.

    PubMed

    Nishino, Michiya; Nikiforova, Marina

    2018-04-01

    - Approximately 15% to 30% of thyroid nodules that undergo fine-needle aspiration are classified as cytologically indeterminate, presenting management challenges for patients and clinicians alike. During the past several years, several molecular tests have been developed to reduce the diagnostic uncertainty of indeterminate thyroid fine-needle aspirations. - To review the methodology, clinical validation, and recent peer-reviewed literature for 4 molecular tests that are currently marketed for cytologically indeterminate thyroid fine-needle aspiration specimens: Afirma, ThyroSeq, ThyGenX/ThyraMIR, and RosettaGX Reveal. - Peer-reviewed literature retrieved from PubMed search, data provided by company websites and representatives, and authors' personal experiences. - The 4 commercially available molecular tests for thyroid cytology offer unique approaches to improve the risk stratification of thyroid nodules. Familiarity with data from the validation studies as well as the emerging literature about test performance in the postvalidation setting can help users to select and interpret these tests in a clinically meaningful way.

  8. Occurrence of coring after needle insertion through a rubber stopper: study with prednisolone acetate.

    PubMed

    Campagna, Raphael; Pessis, Eric; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc

    2013-02-01

    To evaluate the occurrence of coring after needle insertion through the rubber stopper of prednisolone acetate vials. Two-hundred vials of prednisolone acetate were randomly distributed to two radiologists. Prednisolone acetate was drawn up through the rubber bung of the vials with an 18-gauge cutting bevelled needle and aspirated with a 5-ml syringe. The presence of coring was noted visually. We systematically put each core in a syringe refilled with 3 ml prednisolone acetate, and injected the medication through a 20-gauge spine needle. Computed tomography was performed to measure the size of each coring. Coring occurred in 21 out of 200 samples (10.5 %), and was visually detected in the syringe filled up with prednisolone in 11 of the 21 cases. Ten more occult cores were detected only after the syringes and needles were taken apart and rinsed. The core size ranged from 0.6 to 1.1 mm, and 1 of the 21 (4.7 %) cores was ejected through the 20-gauge needle. Coring can occur after the insertion of a needle through the rubber stopper of a vial of prednisolone acetate, and the resultant core can then be aspirated into the syringe.

  9. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  10. [Variations in the diagnostic confirmation process between breast cancer mass screening units].

    PubMed

    Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier

    2016-01-01

    To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  11. Correlation of ultrasonographic appearance of lesions and cytologic and histologic diagnoses in splenic aspirates from dogs and cats: 32 cases (2002-2005).

    PubMed

    Ballegeer, Elizabeth A; Forrest, Lisa J; Dickinson, Ryan M; Schutten, Melissa M; Delaney, Fern A; Young, Karen M

    2007-03-01

    To determine the accuracy of cytologic diagnosis, compared with histologic diagnosis, in determination of disease in ultrasound-guided fine-needle aspirates of splenic lesions. Retrospective study. Splenic specimens from 29 dogs and 3 cats. Records were searched for dogs and cats that had undergone ultrasound-guided splenic aspiration. Criteria for inclusion were ultrasonographic identification of splenic lesions and cytologic and histologic evaluation of tissue from the same lesion. Cytologic samples were obtained by fine-needle aspiration, and histologic specimens were obtained via surgical biopsy, ultrasound-guided biopsy, or necropsy. Cytologic diagnoses corresponded with histologic diagnoses in 19 of 31 (61.3%) cases and differed in 5 of 31(16.1%) cases, and 1 aspirate was inadequate for evaluation. In 7 of 31 (22.6%) cases, histologic evaluation of tissue architecture was required to distinguish between reactive and neoplastic conditions. On the basis of histologic diagnosis in 14 animals with nonneoplastic conditions, the cytologic diagnosis was correct in 11 cases, not definitive in 2 cases, and incorrect in 1 case. In 17 animals with malignant neoplastic diseases, the cytologic diagnosis was correct in 8 cases, not definitive but consistent with possible neoplasia in 5 cases, and incorrect in 4 cases. Multiple similar-appearing nodules were significantly associated with malignancy, whereas single lesions were more often benign. Ultrasound-guided aspiration of splenic lesions is a minimally invasive tool for obtaining specimens for cytologic evaluation. Although cytologic diagnoses often reflect histologic results, if missampling or incomplete sampling occurs or tissue architecture is required to distinguish between reactive and neoplastic conditions, accurate diagnosis with fine-needle aspiration may not be possible.

  12. Effectiveness of Toyota process redesign in reducing thyroid gland fine-needle aspiration error.

    PubMed

    Raab, Stephen S; Grzybicki, Dana Marie; Sudilovsky, Daniel; Balassanian, Ronald; Janosky, Janine E; Vrbin, Colleen M

    2006-10-01

    Our objective was to determine whether the Toyota Production System process redesign resulted in diagnostic error reduction for patients who underwent cytologic evaluation of thyroid nodules. In this longitudinal, nonconcurrent cohort study, we compared the diagnostic error frequency of a thyroid aspiration service before and after implementation of error reduction initiatives consisting of adoption of a standardized diagnostic terminology scheme and an immediate interpretation service. A total of 2,424 patients underwent aspiration. Following terminology standardization, the false-negative rate decreased from 41.8% to 19.1% (P = .006), the specimen nondiagnostic rate increased from 5.8% to 19.8% (P < .001), and the sensitivity increased from 70.2% to 90.6% (P < .001). Cases with an immediate interpretation had a lower noninterpretable specimen rate than those without immediate interpretation (P < .001). Toyota process change led to significantly fewer diagnostic errors for patients who underwent thyroid fine-needle aspiration.

  13. [Value of ultrasonically-guided liver puncture biopsy in the diagnosis of primary liver cancer. Apropos of 84 cases].

    PubMed

    Peghini, M; Eynard, J P; Vergne, R; Seurat, P; Barabe, P; Aubry, P; Diallo, A; Gueye, P M

    1987-01-01

    Ultrasonographicaly guided fine needle aspiration of liver was performed in 84 patients having a confirmed HCC. This technics utilizes a CHIBA type fine needle, after blood coagulation tests have been checked. Out of 84 fine needle aspirations performed: 64 were positive (76,2%), 9 negative (10,7%), 11 (13,19%) were questionable (6) or nonanalysable (5). It is ascertained that the sensibility of this technics is over 75%. It should be possible to improve it by repeating such an exam in previously negative patients. The causes of failure are discussed. Tolerance of the technics is good. It is attraumatic, and of very easily performance. No accident, no mishap was noted.

  14. Aspiration cytology of extramammary tumours metastatic to the breast.

    PubMed

    Handa, Uma; Chhabra, Seema; Mohan, Harsh

    2007-10-01

    This study was undertaken to highlight the use of fine needle aspiration cytology (FNAC) to distinguish tumours metastatic to the breast from primary breast malignancies. A total of 1866 fine needle aspirates of the breast were performed during a period of 7 years. Three hundred and fourteen cases of breast malignancies were diagnosed and 5 (1.5%) out of these cases were metastatic in origin. The metastatic tumors included, 2 cases of malignant melanoma (chest wall and left arm), 1 case each of haematolymphoid malignancy, adenocarcinoma of the ovary, and squamous cell carcinoma (left leg). FNA diagnosis of metastasis to the breast is essential in order to avoid unnecessary mastectomy and to ensure appropriate chemotherapy and/or irradiation treatment.

  15. Bone marrow biopsy

    MedlinePlus

    ... aspiration removes a small amount of marrow in liquid form for examination. ... and a syringe is used to withdraw the liquid bone marrow. If this is done, the needle will be removed and repositioned. Or, another needle may be used for the biopsy.

  16. Fine needle aspiration cytology of subcutaneous cysticercosis of the breast. Case report and pathogenic discussion.

    PubMed

    Vuong, P N

    1989-01-01

    A case of subcutaneous cysticercosis of the breast diagnosed by fine needle aspiration cytology is reported. The cytologic preparations showed the presence of many inflammatory cells mixed with spiked spherules resembling the rambutan tropical fruit. These spherules arose from the degenerated integument of the parasite found in the histologically excised cyst. They are suggestive of the presence of an encysted flat worm, but are not specific for cysticercosis, whose identification is based on the study of the cephalic extremity of the parasite.

  17. Painless giant cell thyroiditis diagnosed by fine needle aspiration and associated with intense thyroidal uptake of gallium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanders, L.R.; Moreno, A.J.; Pittman, D.L.

    1986-05-01

    A 52-year-old woman presented with fever, goiter, and no evidence of pain or tenderness in the thyroid. A diagnosis of silent thyroiditis was made after obtaining evidence of biochemical thyrotoxicosis, intense gallium-67 citrate thyroidal localization, and cytologic thyroiditis. Fine needle aspiration biopsy of the thyroid revealed numerous giant cells in all areas of the thyroid, typical of subacute thyroiditis. This is believed to be the first time painless thyroiditis is reported with the classic cytologic feature of painful subacute thyroiditis.

  18. [Congenital neck mass. Diagnosis and treatment].

    PubMed

    Muñoz-Proto, F; Sarría-Echegaray, P; Epprecht-González, M P; Alba-Mesquida, J

    2016-01-01

    Congenital neck masses are a challenge for general practitioners and specialists. Although some of them are diagnosed in utero, most of them remain silent until complications appear in the adult age. The anatomical location, consistency and age are determinants in guiding the possible diagnosis. A midline infrahyoid mass may be a thyroglossal cyst, however a lateral neck mass is more possible to result in a brachial cyst. Complementary imaging studies are essential such as pathological tests like needle aspiration fine needle aspiration (FNA). Copyright © 2015. Publicado por Elsevier España, S.L.U.

  19. Fine needle aspiration cytology.

    PubMed Central

    Lever, J V; Trott, P A; Webb, A J

    1985-01-01

    Fine needle aspiration cytology is an inexpensive, atraumatic technique for the diagnosis of disease sites. This paper describes the technique and illustrates how it may be applied to the management of tumours throughout the body. The limitations of the method, the dangers of false positive reports, and the inevitability of false negative diagnoses are emphasised. In a clinical context the method has much to offer by saving patients from inappropriate operations and investigations and allowing surgeons to plan quickly and more rationally. It is an economically valuable technique and deserves greater recognition. Images PMID:2578481

  20. A comparison of the Cook single lumen immature ovum IVM needle to the Steiner-Tan pseudo double lumen flushing needle for oocyte retrieval for IVM.

    PubMed

    Rose, B I; Laky, D

    2013-06-01

    This study compared the impact of using the Steiner-Tan pseudo double lumen needle for antral follicle oocyte retrieval to using a conventional non-flushing needle. The Steiner-Tan needle has a much smaller dead space than the needles commonly used for IVM oocyte retrievals. This was a retrospective cohort study. The patient population was determined by the time period in which a patient underwent IVM in a single physician's IVF practice. The following data was abstracted from clinical and embryology records: oocytes retrieved, oocytes matured, early maturing oocytes, oocytes fertilized, embryo quality measures, retrieval time, needle punctures, clot formation, and clinical pregnancy rate. The Steiner-Tan needle did not increase the number of oocytes retrieved. It also did not increase the time required for retrieval. However, flushing of antral follicles significantly decreased clot formation in fluid aspirates. Use of the Steiner-Tan needle also significantly decreased the number of vaginal needle punctures during each case. There was a trend toward improved embryo quality, but statistical power was inadequate to show a difference. The primary benefit of the Steiner-Tan needle was on the embryological aspects of IVM. Decreased blood and blood clots in the aspirates made an IVM retrieval more like conventional IVF for the embryologist. The patient also experienced less tissue trauma without increasing anesthesia or surgical time. There was no improvement in the number of oocytes retrieved, but based on the results, we hypothesized that oocytes were more commonly retrieved from slightly large follicles than when using a routine needle.

  1. Bronchoscopy in the investigation of outpatients with hemoptysis at a lung cancer clinic.

    PubMed

    Arooj, Parniya; Bredin, Emily; Henry, Michael T; Khan, Kashif A; Plant, Barry J; Murphy, Desmond M; Kennedy, Marcus P

    2018-06-01

    In the investigation of lung cancer, current practice in many healthcare systems would support bronchoscopy regardless of CT findings in patients with hemoptysis. We sought to identify the cause, the diagnostic yield of CT and bronchoscopy and the requirement for bronchoscopy in at risk patients with hemoptysis with a normal CT scan through our rapid access lung cancer clinic (RALC). Initially, a chart review was performed on all patients with hemoptysis (2011-2012) and thereafter a prospective analysis was performed (2013-2016). Our analysis represents the largest study to date in outpatients with hemoptysis. In our retrospective study, 155 patients reported hemoptysis. Causes were lower respiratory tract infections (RTIs) (47%) and lung cancer (16%). Our prospective study included 182 patients. The causes of hemoptysis were RTIs (50%) and lung cancer (18%). There were no false negative CT-scans for lung cancer. 47/57 present with lung cancer underwent bronchoscopy and 43/47 were positive for lung cancer (92%). Patients with hemoptysis and lung cancer have a higher stage of malignancy with a predominance of squamous cell lung carcinoma. Smoking status, the duration of hemoptysis or description of hemoptysis were not predictive of lung cancer however lung cancer was not identified in patients age <50. One sixth of patients presenting with hemoptysis to our lung cancer clinic had lung cancer. No patient identified with cancer related haemoptysis had a CT negative for lung cancer and a combination of bronchoscopy plus endobronchial ultrasound trans-bronchial needle aspiration (EBUS-TBNA) in those patients with a CT suspicious of lung cancer is 92% sensitive for lung cancer causing hemoptysis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Utility of percutaneous joint aspiration and synovial biopsy in identifying culture-positive infected hip arthroplasty.

    PubMed

    Cross, M Connor; Kransdorf, Mark J; Chivers, F Spencer; Lorans, Roxanne; Roberts, Catherine C; Schwartz, Adam J; Beauchamp, Christopher P

    2014-02-01

    Percutaneous synovial biopsy has recently been reported to have a high diagnostic value in the preoperative identification of periprosthetic infection of the hip. We report our experience with this technique in the evaluation of patients undergoing revision hip arthroplasty, comparing results of preoperative synovial biopsy with joint aspiration in identifying an infected hip arthroplasty by bacteriological analysis. We retrospectively reviewed the results of the 110 most recent revision hip arthroplasties in which preoperative synovial biopsy and joint aspiration were both performed. Revision surgery for these patients occurred during the period from September 2005 to March 2012. Using this study group, results from preoperative cultures were compared with preoperative laboratory studies and the results of intraoperative cultures. Synovial aspiration was done using an 18- or 20-gauge spinal needle. Synovial biopsy was done coaxially following aspiration using a 22-gauge Chiba needle or 21-gauge Sure-Cut needle. Standard microbiological analysis was performed on preoperative synovial fluid aspirate and synovial biopsy. Intraoperative tissue biopsy bacteriological analysis results at surgical revision were accepted as the "gold standard" for the presence or absence of infection. Seventeen of 110 (15 %) of patients had intraoperative culture-positive periprosthetic infection. Of these 17 cases, there were ten cases where either the synovial fluid aspiration and/or the synovial biopsy were true positive (sensitivity of 59 %, specificity of 100 %, positive predictive value of 100 % and accuracy of 94 %). There were seven cases where aspiration and biopsy results were both falsely negative, but no false-positive results. Similar results were found for synovial fluid aspiration alone. The results of synovial biopsy alone resulted in the identification of seven infected joints with no false-positive result (sensitivity of 41 %, specificity of 100 %, positive predictive value of 100 %, and accuracy of 91 %). Standard microbiological analyses performed on percutaneous synovial biopsy specimen during the preoperative evaluation of patients undergoing revision hip arthroplasty did not improve detection of culture-positive periprosthetic infection as compared to synovial fluid aspiration alone.

  3. Image-guided fine-needle aspiration of retroperitoneal masses: The role of the cytopathologist.

    PubMed

    Mehdi, Ghazala; Maheshwari, Veena; Afzal, Sheerin; Ansari, Hena A; Ahmad, Ibne

    2013-01-01

    Retroperitoneal tumors constitute a difficult diagnostic category as they are not easily accessible. The advent of image-guided fine-needle aspiration (FNA) has resolved this problem significantly. We present a short study based on guided aspiration of retroperitoneal tumors, in which we have tried to assess the role of image-guided fine-needle aspiration cytology as a tool for pre-operative diagnosis. The study was conducted on patients diagnosed with retroperitoneal masses. FNA was performed under image guidance with the help of ultrasonography and/or computed tomography; smears were prepared and meticulously screened according to a fixed protocol. The results were analyzed to determine sensitivity, specificity, and diagnostic efficacy of cytopathological diagnosis using image-guided FNA techniques. We assessed 38 patients with retroperitoneal masses. In all cases, adequate cellular material was obtained. No major complications were encountered. Statistical analysis was carried out in 35 cases; sensitivity, specificity, and diagnostic accuracy were 100% in these cases. FNA under image guidance should be considered a first-line diagnostic approach for retroperitoneal and other abdominal tumors, although caution should be exercised in case selection. In areas where advanced tests are not available, the cytotechnologist and cytopathologist have a very important role to play in ensuring accurate diagnoses.

  4. Aspiration cytology of mesenchymal hamartoma of the chest wall: a case report and literature review.

    PubMed

    Taweevisit, Mana; Trinavarat, Panruethai; Thorner, Paul Scott

    2014-10-01

    Mesenchymal hamartoma of the chest wall is a rare tumor-like lesion of infancy and childhood. The few available descriptions of the findings on fine needle aspiration list spindle-shaped cells and cartilage or chondromyxoid material as essential features for this diagnosis. An aggressive appearance on imaging studies and a lack of familiarity with this lesion, can lead the pathologist to misdiagnose the cytologic findings as malignancy. We reported a 5-month-old male presenting with a mass of the right chest wall progressively for 2 months. Radiologic studies showed a mixed solid and cystic mass originating from the third, fourth and fifth ribs, and a diagnosis of malignancy was favored. Fine needle aspiration recovered only spindle-shaped cells and a few multinucleated giant cells of osteoclast type. After a review of the imaging, a diagnosis of mesenchymal hamartoma of the chest wall was raised. This diagnosis was confirmed by pathologic examination of the subsequently resected mass. This is the sixth report of a mesenchymal hamartoma of the chest wall diagnosed by fine needle aspiration. This case illustrates that this diagnosis can be suspected in the absence of cartilage or chondromyxoid material, given appropriate clinical and radiologic findings. © 2014 Wiley Periodicals, Inc.

  5. Thermal comparison of Infiniti OZil and Signature Ellips phacoemulsification systems.

    PubMed

    Schmutz, Joseph S; Olson, Randall J

    2010-05-01

    To determine thermal characteristics of Signature Ellips (Abbott Medical Optics) and Infiniti OZil (Alcon, Inc.) transverse ultrasound and compare both with longitudinal ultrasound in clinically relevant scenarios. Laboratory investigation. Temperature increase over baseline after 60 seconds was measured in water at positions in 90-degree increments around the sleeve near the proximal needle shaft in an artificial chamber for Ellips and OZil on continuous ultrasound with aspiration blocked and unblocked. This was also done with Signature using longitudinal ultrasound, with and without micropulse (6 ms on, 12 ms off), with aspiration blocked and unblocked, and at the OZil sleeve tip on continuous transverse mode with aspiration unblocked. OZil (8.1 +/- 0.3 C) had greater temperature increase than Ellips (5.2 +/- 0.3 C; P < .0001) with aspiration unblocked and blocked (29.3 +/- 1.0 C vs 12.2 +/- 0.7 C; P < .0001). OZil had uneven distribution of heat around the shaft (30.1 +/- 0.5 C vs 28.5 +/- 0.6 C; P < .0001), whereas Ellips did not (P = .57). OZil was cooler at the tip (6.6 +/- 0.2 C; P < .0001). Friction in a cadaver eye incision only increased these numbers by 10% (OZil, irrigation blocked). Metal stress probably creates heat at the proximal needle junction for both transverse methods. Heat generation differences between OZil and Ellips result from the manner in which they create needle motion. Incision burns may occur, especially for OZil, under nonpulsed settings during fragment removal with occlusion when reaching across the anterior chamber such that the proximal needle shaft came near the wound. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Comparison of incision and drainage against needle aspiration for the treatment of breast abscess.

    PubMed

    Naeem, Muhammad; Rahimnajjad, Muhammad Kazim; Rahimnajjad, Nasir Ali; Ahmed, Qazi Jalaluddin; Fazel, Pyar Ali; Owais, Muhammad

    2012-11-01

    We aim to compare the incision and drainage against ultrasound-guided aspiration for the treatment of breast abscesses. Sixty-four patients were randomly allocated to Group A (incision and drainage) and Group B (needle aspiration). Incision and drainage was done under general, whereas aspiration was done under local anesthesia with antibiotic coverage after the pus sample was taken for cultures. Time taken to resolve symptoms including point tenderness, erythema and hyperthermia, recurrence of breast abscess, and healing time was recorded. Patients were followed until 8 weeks. Culture and sensitivity of the pus were done. Data were analyzed in SPSS 16.0. The mean difference of healing time was significant (P = 0.001). A total of 93.3 per cent were healed in Group B and 76.6 per cent in Group A (P = 0.033). Twenty-two samples (34.37%) had no bacterial yield and the remaining 42 samples (65.6%) yielded 11 anaerobic cultures (17.18%) and 31 aerobic cultures (48.4%). Ultrasound-guided aspiration of breast abscesses with the judicious use of antibiotics is a better treatment modality than incision and drainage.

  7. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    PubMed

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  8. Molecular Signature of Indeterminate Thyroid Lesions: Current Methods to Improve Fine Needle Aspiration Cytology (FNAC) Diagnosis

    PubMed Central

    Cantara, Silvia; Marzocchi, Carlotta; Pilli, Tania; Cardinale, Sandro; Forleo, Raffaella; Castagna, Maria Grazia; Pacini, Furio

    2017-01-01

    Fine needle aspiration cytology (FNAC) represents the gold standard for determining the nature of thyroid nodules. It is a reliable method with good sensitivity and specificity. However, indeterminate lesions remain a diagnostic challenge and researchers have contributed molecular markers to search for in cytological material to refine FNAC diagnosis and avoid unnecessary surgeries. Nowadays, several “home-made” methods as well as commercial tests are available to investigate the molecular signature of an aspirate. Moreover, other markers (i.e., microRNA, and circulating tumor cells) have been proposed to discriminate benign from malignant thyroid lesions. Here, we review the literature and provide data from our laboratory on mutational analysis of FNAC material and circulating microRNA expression obtained in the last 6 years. PMID:28383480

  9. Polymerase chain reaction in the detection of tumor cells: new approaches in diagnosis and follow-up of patients with thyroid cancer.

    PubMed

    Bojunga, Jörg; Kusterer, Klaus; Schumm-Draeger, Petra-Maria; Usadel, Klaus-Henning

    2002-12-01

    Thyroid cancers are the most common endocrine malignancies and are being diagnosed with increasing frequency. In addition to other measures, diagnosis is based on fine-needle aspiration cytology examination. Recently, new assays using reverse transcription-polymerase chain reaction (PCR) are being tested to improve sensitivity and specificity of primary diagnosis and detection of recurrent thyroid cancer. In the preoperative diagnosis of thyroid cancer, several tissue- and/or tumor-specific mRNA have been described and in several cases, a higher sensitivity and specificity could be achieved using molecular techniques compared to conventional methods. In the postoperative follow-up of patients with thyroid cancer, conflicting data have been published and the use of PCR techniques revealed several problems of the molecular approach, which are based on some technical as well as biologic limitations. Despite these problems, which are discussed in detail in this review, molecular techniques may nevertheless improve the sensitivity and accuracy of fine-needle aspiration of thyroid nodules, fine-needle aspiration of metastases, and detection of recurrent disease in peripheral blood samples.

  10. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    PubMed Central

    Raquel, Garza-Guajardo; Nora, Mendez-Olvera; Pablo, Flores-Gutierrez Juan; Silvia, Hernandez-Martinez; Michelle, Candanosa-Mc Cann; Jesús, Ancer-Rodriguez; Oralia, Barboza-Quintana

    2005-01-01

    Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures. PMID:16174298

  11. Role of fine needle aspiration cytology and cell block in diagnosis of scar endometriosis: A case report

    PubMed Central

    Dash, Sashibhusan; Panda, Sasmita; Rout, Niranjan; Samantaray, Sagarika

    2015-01-01

    Presence of endometrial glands and stroma in places other than the uterus is called endometriosis. It can be pelvic or extra-pelvic. Abdominal scar endometriosis is an extra-pelvic endometriosis that can occur after surgery involving the uterus. Post-caesarean section, scar endometriosis is a rare event. The diagnosis is frequently made only after excision of disease tissue. We present a case of post-caesarean section abdominal scar endometriosis presenting as a tumor on the abdominal wall, which was diagnosed by fine needle aspiration cytology and confirmed by cell block preparation. PMID:25948955

  12. Breast abscess as a complication of human brucellosis.

    PubMed

    Gurleyik, Emin

    2006-01-01

    Breast abscess caused by human brucellosis is extremely rare. A 46-year-old woman received the diagnosis of brucellosis with positive serologic tests. Two weeks after the onset of symptoms, the case was complicated by vertebral (L5-S1) abscess which was treated by surgical drainage. One month after the diagnosis of brucellosis, the patient noticed a mass in her left breast. Breast palpation revealed a painless, mobile, round mass that was hypoechoic on ultrasound imaging. Purulent material was obtained by needle aspiration. Besides treatment of the breast abscess by needle aspiration, brucellosis was successfully controlled by prolonged antimicrobial treatment.

  13. The value of fine needle aspiration and cytologic examination of impalpable complicated breast cysts.

    PubMed

    Tez, Selda; Dener, Cenap; Köktener, Aslý; Caydere, Muzaffer; Tez, Mesut

    2008-01-01

    The purpose of the study was to evaluate the utility of fine needle aspiration--FNA and cytologic analysis of impalpable complicated breast cysts. We rewieved the imaging findings, aspiration, cytology and biopsy results and followup imaging findings of 246 complicated cysts in 166 women retrospectively. FNA was performed in 169 out of the 246 complicated cysts. Thirtyone lesions were followed-up with US. Surgical biopsy was performed from five lesions. No malignant cells (137 cysts), insufficient cellular material (17 cysts), atypical cells (4 cysts) were seen in cytological examination of the aspirates. None of these lesions were found to represent malignancy at the time of surgical excision and during follow-up. Impalpable complicated breast cysts may be classified as probably benign and can be managed with follow-up imaging studies instead of intervention. Routine cytologic examination is unnecessary if the fluid is not bloody (Tab. 2, Ref. 18). Full Text (Free, PDF) www.bmj.sk.

  14. Thyroid fine-needle aspiration cytology: performance data of neoplastic and malignant cases as identified from 1558 responses in the ASCP Non-GYN Assessment program thyroid fine-needle performance data.

    PubMed

    Eilers, Stan G; LaPolice, Paula; Mukunyadzi, Perkins; Kapur, Umesh; Wendel Spiczka, Amy; Shah, Ajay; Saleh, Husain; Adeniran, Adebowale; Nunez, Amberly; Balachandran, Indra; Clark, Jennifer J; Lemon, Larry

    2014-10-01

    Fine-needle aspiration of the thyroid is a common procedure, with an established role in reducing unnecessary thyroid surgery and identifying neoplasms and malignancies. The study evaluated 1558 responses in the American Society for Clinical Pathology (ASCP) Non-GYN Assessment program of aspirates of thyroid neoplasms and malignancies and placed them into the following groups: group A (target or correct interpretation), group B (incorrect interpretation as a benign thyroid nodule), group C (incorrect interpretation malignant aspirate as thyroid neoplasm), and group D (malignant diagnosis with incorrect interpretation). In clinical practice, responses in groups A, C, and D would lead to surgical excision, whereas responses in group B would not. Of a total of 1558 responses, 78.5% of the responses were in group A, 8.5% in group B, 3.75% in group C, and 9.25% in group D. By individual diagnosis, the group rates were 86.5%, 0%, 11%, and 2.5% for anaplastic thyroid carcinoma; 83%, 5.5%, 4.25%, and 7.25% for papillary thyroid carcinoma; 79%, 7%, 6%, and 8% for medullary thyroid carcinoma; 83.5% 6.75%, 0%, and 9.75% for Hürthle cell neoplasm; and 61%, 22%, 0%, and 17% for follicular neoplasm in groups A, B, C, and D respectively. Fine-needle aspiration was effective in diagnosing thyroid neoplasms and malignancies and in separating thyroid nodules into surgical and nonsurgical categories. Data from a large group of cytology professionals showed good performance; however, there is room for improvement, especially in making specific diagnoses. In particular, follicular neoplasm and follicular variant of papillary thyroid carcinoma were challenging diagnoses for participants. © 2014 The Authors. Cancer Cytopathology published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  15. FNAC Versus Core Needle Biopsy: A Comparative Study in Evaluation of Palpable Breast Lump

    PubMed Central

    Saha, Abhijit; Mukhopadhyay, Madhumita; Sarkar, Koushik; Saha, Ashis Kumar; Sarkar, Diptendra KR

    2016-01-01

    Introduction Breast carcinoma is the most common malignant tumour and the leading cause of carcinoma death in women in world. The main purpose of FNAC or CNB of breast lumps is to confirm cancer preoperatively and to avoid unnecessary surgery in specific benign conditions. Aims and Objective The objective of the study was to compare between Fine Needle Aspiration Cytology (FNAC) and Core Needle Biopsy (CNB) in the diagnosis of breast carcinoma with final histological diagnosis from excision specimen as it is gold standard. Materials and Methods A prospective study was done on 50 cases. Patients undergoing all three procedures (Fine Needle Aspiration Cytology and Core Needle Biopsy done at Department of Pathology; subsequent excision surgeries done at Department of General Surgery) were selected. May Grunwald Giemsa (MGG) and Papaniculou (PAP) staining were performed on cytology smears. Haematoxylin and Eosin (H&E) staining was done on both the CNB and tissue specimens obtained from subsequent excision surgeries to see the histological features. Results FNAC showed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 69%, 100%, 100%, 38.1%, and 74% respectively in diagnosing carcinoma. CNB had sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 88.3%, 100%, 100%, 53.3% and 86%. Both FNAC and CNB showed statistically significant correlation with confirmatory HPE of excision specimen (p-value <0.05) in the diagnosis of breast carcinoma. Conclusion Fine needle aspiration cytology (FNAC) is a rapid, less complicated, economical, reliable and relevant method for the preoperative pathological diagnosis of breast carcinoma in a developing nation like ours. If the initial FNAC is inadequate, core needle biopsy (CNB) can be a useful second line method of pathological diagnosis in order to minimize the chance of missed diagnosis of breast cancer. PMID:27042469

  16. Diagnosis of peritoneal mesothelioma: computed tomography, sonography, and fine-needle aspiration biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reuter, K.; Raptopoulos, V.; Reale, F.

    1983-06-01

    The diagnosis of peritoneal mesothelioma was made prospectively and noninvasively in four patients with the use of sonography, computed tomography, and sonographically guided fine-needle aspiration biopsy. The imaging methods revealed information similar to the operative findings, with clear superiority of computed tomography over sonography. These noninvasive methods may be used as screening tools, especially among groups or in regional areas with a high risk for asbestos exposure. The findings included soft-tissue masses with invariable involvement of the omentum; small intraperitoneal nodules; thickened peritoneum, mesentery, and bowel wall; pleural plaques; and usually minimal, if any, ascites. Since the differential diagnosis frommore » peritoneal carcinomatosis may be difficult, sonographically (or CT) guided aspiration biopsy is needed to produce diagnostic cytologic specimens. The use of this type of biopsy should obviate surgical exploration.« less

  17. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration With a 19-G Needle Device.

    PubMed

    Tremblay, Alain; McFadden, Seamus; Bonifazi, Martina; Luzzi, Valentina; Kemp, Samuel V; Gasparini, Stefano; Chee, Alex; MacEachern, Paul; Dumoulin, Elaine; A Hergott, Christopher; Shah, Pallav L

    2018-05-16

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration is a well-established first-line minimally invasive modality for mediastinal lymph node sampling. Although results are excellent overall, the technique underperforms in certain situations. We aimed to describe our results using a new 19-G EBUS-guided transbronchial needle aspiration device to determine safety and feasibility of this approach. We completed a retrospective chart review of all cases performed to the time of data analysis at each of 3 study sites. A total of 165 procedures were performed with a total of 297 individual lymph nodes or lesions sampled with the 19-G device by 10 bronchoscopists. Relatively large targets were selected for sampling with the device (mean lymph node size: 20.4 mm; lung lesions: 33.5 mm). A specific diagnosis was obtained in 77.3% of cases with an additional 13.6% of cases with benign lymphocytes, for a procedural adequacy rate of 90.9%. Procedure sample adequacy was 88.6% in suspected malignant cases, 91.0% in suspected sarcoidosis/lymphadenopathy cases, and 85.7% of cases with suspected lymphoma. On a per-node basis, a specific diagnosis was noted in 191/280 (68.2%) of samples, with an additional 61 showing benign lymphocytes for a per-node sample adequacy rate of 90%. One case (0.6%) of intraprocedure bleeding was noted. A new flexible 19-G EBUS needle was successfully and safely applied in a large patient cohort for sampling of lung and enlarged mediastinal lesions with high diagnostic rates across clinical indications.

  18. Initiation and Characterization of Small Cell Lung Cancer Patient-Derived Xenografts from Ultrasound-Guided Transbronchial Needle Aspirates

    PubMed Central

    Anderson, Wade C.; Boyd, Michael B.; Aguilar, Jorge; Pickell, Brett; Laysang, Amy; Pysz, Marybeth A.; Bheddah, Sheila; Ramoth, Johanna; Slingerland, Brian C.; Dylla, Scott J.; Rubio, Edmundo R.

    2015-01-01

    Small cell lung cancer (SCLC) is a devastating disease with limited treatment options. Due to its early metastatic nature and rapid growth, surgical resection is rare. Standard of care treatment regimens remain largely unchanged since the 1980’s, and five-year survival lingers near 5%. Patient-derived xenograft (PDX) models have been established for other tumor types, amplifying material for research and serving as models for preclinical experimentation; however, limited availability of primary tissue has curtailed development of these models for SCLC. The objective of this study was to establish PDX models from commonly collected fine needle aspirate biopsies of primary SCLC tumors, and to assess their utility as research models of primary SCLC tumors. These transbronchial needle aspirates efficiently engrafted as xenografts, and tumor histomorphology was similar to primary tumors. Resulting tumors were further characterized by H&E and immunohistochemistry, cryopreserved, and used to propagate tumor-bearing mice for the evaluation of standard of care chemotherapy regimens, to assess their utility as models for tumors in SCLC patients. When treated with Cisplatin and Etoposide, tumor-bearing mice responded similarly to patients from whom the tumors originated. Here, we demonstrate that PDX tumor models can be efficiently established from primary SCLC transbronchial needle aspirates, even after overnight shipping, and that resulting xenograft tumors are similar to matched primary tumors in cancer patients by both histology and chemo-sensitivity. This method enables physicians at non-research institutions to collaboratively contribute to the rapid establishment of extensive PDX collections of SCLC, enabling experimentation with clinically relevant tissues and development of improved therapies for SCLC patients. PMID:25955027

  19. Skin and soft tissue infections: experience over a five-year period and clinical usefulness of ultrasonography-guided gun biopsy-based culture.

    PubMed

    Noh, Ji Yun; Cheong, Hee Jin; Song, Joon Young; Hong, Suk-Joo; Myung, Jae Sung; Choi, Won Suk; Jo, Yu Mi; Heo, Jung Yeon; Kim, Woo Joo

    2011-12-01

    Skin and soft tissue infections (SSTIs) are common clinical diseases, but only a few reports of microbiological data on SSTIs in Korea have been published. In practice, specimens are rarely obtained from infected lesions unless there is visible pus or an abscess pocket. However, identification of the causative pathogen is important, because of emerging drug resistance and the increase in immunocompromised hosts. The medical records of 760 adult cases of community-acquired SSTIs (CA-SSTIs) from September 2003 to August 2008 were reviewed retrospectively. We analyzed epidemio-clinical features and microbiological distributions of CA-SSTIs and evaluated the positive culture rate of several diagnostic methods, including swab, tissue biopsy, blind needle aspiration, ultrasonography (US)-guided needle aspiration, and US-guided gun biopsy. Most CA-SSTIs (76.1%) occurred in previously healthy persons without underlying diseases. Re-infections were identified in 76 (10%) patients and cirrhosis was an independent risk factor for re-infection (odds ratio 3.64, 95% confidence interval 1.36-9.76). The most commonly identified pathogen was methicillin-susceptible Staphylococcus aureus, and 3(rd)-generation cephalosporins were the most commonly used empirical antibiotics (47.9%). US-guided needle aspiration had a high positive culture rate of 73.9% and the positive culture rate of US-guided gun biopsy was 17.5%. Considering the microbiological distribution of CA-SSTIs in Korea, penicillinase-stable penicillin or a 1(st)-generation cephalosporin should be adequate for initial antibiotic treatment. US-guided needle aspiration was a good technique for the identification of causative pathogens, and additive productivity is expected with US-guided gun biopsy culture from lesions without fluid collection.

  20. Rapid detection of metastatic melanoma in lymph nodes using proton magnetic resonance spectroscopy of fine needle aspiration biopsy specimens.

    PubMed

    Lean, Cynthia L; Bourne, Roger; Thompson, John F; Scolyer, Richard A; Stretch, Jonathan; Li, Ling-Xi Lawrence; Russell, Peter; Mountford, Carolyn

    2003-06-01

    Accurate staging of patients with primary cutaneous melanoma includes assessment of regional lymph nodes for the presence of micrometastatic disease. Sentinel lymph node biopsy is highly accurate but is an invasive surgical procedure with a 5-10% complication rate, and requires labour-intensive and expensive histological examination to identify disease. A rapid, accurate and cost-effective non-surgical technique able to detect micrometastatic deposits of melanoma in regional lymph nodes would be of great benefit. Fine needle aspiration biopsies and tissue specimens were obtained from lymph nodes from 18 patients undergoing node resection for metastatic melanoma and five patients undergoing radical retropubic prostatectomy. One-dimensional proton magnetic resonance spectroscopy was undertaken at 360 MHz (8.5 T). Lymph nodes were cut into 3 mm thick slices and embedded. Four sequential 5 microm tissue sections were cut from each block and stained, with haematoxylin and eosin, for S100 protein, for HMB45, and again with haematoxylin and eosin, respectively. Proton magnetic resonance spectroscopy distinguished between benign and malignant lymph node tissue (P < 0.001, separate t-test) and benign and malignant lymph node fine needle aspiration biopsy (P < 0.012) based on the ratio of the integrals of resonances from lipid/other metabolites (1.8-2.5 p.p.m. region) and 'choline' (3.1-3.3 p.p.m. region). In conclusion, one-dimensional proton magnetic resonance spectroscopy on a simple fine needle aspiration biopsy can distinguish lymph nodes containing metastatic melanoma from uninvolved nodes, providing a rapid, accurate and cost-effective non-surgical technique to assess regional lymph nodes in patients with melanoma.

  1. Reconstituting botulinum toxin drugs: shaking, stirring or what?

    PubMed

    Dressler, Dirk; Bigalke, Hans

    2016-05-01

    Most botulinum toxin (BT) drugs are stored as powders which need to be reconstituted with normal saline before clinical use. As botulinum neurotoxin (BNT), the therapeutically active ingredient, is a large double-stranded protein the process of reconstitution should be performed with special attention to mechanical stress applied. We wanted to test the mechanical stability of BNT during the reconstitution process. For this, 100 MU onabotulinumtoxinA (Botox(®), Irvine, CA, USA) was reconstituted with 2.0 ml of NaCl/H2O. Gentle reconstitution (GR) was performed with a 5 ml syringe, a 0.90 × 70 mm injection needle, one cycle of injection-aspiration-injection and two gentle shakes of the vial. Aggressive reconstitution (AR) was performed with a 5 ml syringe, a 0.40 × 40 mm injection needle, ten injection-aspiration-injection cycles and 30 s of continuous shaking of the vial. AR increased the time to paralysis in the mouse hemidiaphragm assay (HDA) from 72.0 ± 4.6 to 106.0 ± 16.0 min (*p = 0.002, two-tailed t test after Kolmogorov-Smirnova test with Lilliefors correction for normal distribution). Construction of a calibration curve revealed that the increase in the time to paralysis was correlated with a loss of potency of from 100 to 58 MU (-42 %). BT users should use large diameter injection needles for reconstitution, apply two or three injection-aspiration-injection cycles and, maybe, shake the vials a few times to rinse the entire glass wall. Aggressive reconstitution with small diameter needles, prolonged injection-aspiration-injection and violent shaking should be avoided.

  2. Bone marrow solid core biopsy needle: a critical assessment of the utility, benefits and limitations of the instruments employed in current day haematology and oncology.

    PubMed

    Islam, Anwarul

    2018-06-01

    The optimal clinical evaluation of the bone marrow requires an examination of air-dried and well-stained films of the aspirated tissue along with a histopathological evaluation of adequately processed and properly stained core biopsy specimens. A bone marrow evaluation can be essential in establishing a diagnosis, determining the efficacy of treatment in haematological disorders and to monitor haematological status of patients following bone marrow/stem cell transplantation. It is also an essential component of the staging process for newly diagnosed malignancies. Currently available bone marrow aspiration needles are quite satisfactory and if properly used provide good-quality specimens for morphological evaluation. However, if a bone marrow core biopsy is concerned, several needles are currently in use but not all of them provide good-quality biopsy specimens for histological evaluation or are user friendly. We have compared the recently introduced Moeller Medical single use bone marrow core biopsy needle with the Jamshidi needle with marrow acquisition cradle (CareFusion), J-needle (Cardinal Health) and OnControl device (Vidacare). It is concluded that the Moeller Medical needle system has definite advantages over others and is recommended for routine use. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.

    PubMed

    Binmoeller, K F; Brand, B; Thul, R; Rathod, V; Soehendra, N

    1998-05-01

    A new mechanical sector scanning echoendoscope designed for EUS-guided, fine-needle aspiration biopsy (FNAB) was prospectively evaluated. The technical feasibility, safety, and histocytologic FNAB results are reported. Eighty-six patients underwent 106 FNAB procedures. The new echoendoscope has a 2.8 mm accessory channel and an elevator. Target sites: pancreas 58, lymph nodes 43, and miscellaneous lesions 5. Lesions were punctured with a 0.7 mm needle and submitted for cytologic and histologic examination. Definitive diagnosis was by surgery or clinical follow-up. The wide scanning field (250 degrees) enabled easy sonographic orientation for FNAB. Longitudinal needle visibility was "good" in 93% and 71% of transesophageal and transgastric procedures, respectively, but were compromised during most transduodenal procedures. Needle penetration of indurated pancreatic lesions failed in two patients, and in four additional patients pancreatic sampling succeeded only after a second attempt using an automated spring-loaded device. The mean number of passes was three. Ten percent of FNAB specimens were "inadequate"; excluding these, the diagnostic accuracy rate was 97%; sensitivity for malignancy was 88.5% and specificity was 100%. EUS-guided FNAB is feasible, safe, and accurate using the new mechanical puncture echoendoscope. Needle visibility needs to be improved, particularly for transduodenal FNAB.

  4. Evaluation of lumbar transforaminal epidural injections with needle placement and contrast flow patterns: a prospective, descriptive report.

    PubMed

    Manchikanti, Laxmaiah; Cash, Kim A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D

    2004-04-01

    Transforaminal epidural steroid injection is one of the commonly employed modalities of treatment in managing nerve root pain. However, there have been no controlled prospective evaluations of epidural and nerve root contrast distribution patterns and other aspects of fluoroscopically directed lumbosacral transforaminal epidural steroid injections. To evaluate contrast flow patterns and intravascular needle placement of fluoroscopically guided lumbosacral transforaminal epidural injections. A prospective, observational study. A total of 100 consecutive patients undergoing fluoroscopically guided transforaminal epidural steroid injections were evaluated. The contrast flow patterns, ventral or dorsal epidural filling, nerve root filling, C-arm time, and intravascular needle placement were evaluated. Ventral epidural filling was seen in 88% of the procedures, in contrast to dorsal filling noted in 9% of the procedures. Nerve root filling was seen in 97% of the procedures. Total intravenous placement of the needle was noted in 22% of the procedures, whereas negative flashback and aspiration was noted in 5% of the procedures. Lumbosacral transforaminal epidural injections, performed under fluoroscopic visualization, provide excellent nerve root filling and ventral epidural filling patterns. However, unrecognized intravascular needle placement with negative flashback or aspiration was noted in 5% of the procedures.

  5. Endoscopic Ultrasound (EUS) Guided Fine Needle Aspiration: A New Modality to Diagnose Peritoneal Tuberculosis in Presence of Decompensated Cirrhosis-A Case Series and Review of Literature.

    PubMed

    Daswani, Ravi; Kumar, Ashish; Singla, Vikas; Kaur, Gagandeep; Sharma, Praveen; Bansal, Naresh; Arora, Anil

    2018-06-01

    The gold-standard for diagnosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the non-specific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal TB. To assess the role of EUS-FNA in the diagnosis of peritoneal tuberculosis in patients with decompensated cirrhosis. Consecutive patients with peritoneal thickening, ascites and decompensated cirrhosis underwent EUS-FNA from the thickened omentum. Presence of granuloma or demonstration of acid fast bacilli was diagnostic of peritoneal tuberculosis. A total of 5 patients with CLD underwent EUS-FNA from omentum. FNA cytology revealed granuloma with multinucleated cells in all patients (100%) and AFB stain was positive in 2 of them (40%). We hereby report the use of EUS guided fine needle aspiration (FNA) of peritoneum as a newer, safe and unexplored technique for diagnosis of peritoneal TB.

  6. Role of endoscopic ultrasonography in evaluation of metastatic lesions to the pancreas: a tertiary cancer center experience.

    PubMed

    Atiq, Muslim; Bhutani, Manoop S; Ross, William A; Raju, Gottumukkala S; Gong, Yun; Tamm, Eric P; Javle, Milind; Wang, Xuemei; Lee, Jeffrey H

    2013-04-01

    Metastatic lesions to the pancreas pose diagnostic challenges with regards to their differentiation from primary pancreatic cancer. Data on the yield of endoscopic ultrasonography (EUS)-guided fine-needle aspiration in detection of these lesions are limited. This is a retrospective review of 23 patients referred to a tertiary referral center for further evaluation of suspected pancreatic metastases. Main outcome measures were diagnostic yield of endoscopic ultrasonography-guided fine-needle aspiration in evaluation of metastatic lesions to the pancreas. Of 644 patients, 23 (3.6%) undergoing EUS of the pancreas were diagnosed to have metastatic disease to the pancreas based on clinical, radiological, and cytological results. Mean (SD) age was 64.3 (11.7) years. Of the 23 patients, 18 (78.3%) were asymptomatic. Mean (SD) size of lesion on EUS was 39.1 (19.9) mm. A diagnosis of malignant lesion was made in 21 of 23 cases, with a diagnostic accuracy of 91.3%. Metastatic lesions to the pancreas present as incidental, solitary mass lesions on staging or surveillance imaging. Endoscopic ultrasonography-guided fine-needle aspiration is an important tool in the characterization and further differentiation of metastatic lesions to the pancreas from primary pancreatic cancer.

  7. Unusual cases of metastases to the breast. A report of 17 cases diagnosed by fine needle aspiration.

    PubMed

    David, Odile; Gattuso, Paolo; Razan, Wafai; Moroz, Krzysztof; Dhurandhar, Nina

    2002-01-01

    Although nonmammary tumors metastatic to the breast are relatively uncommon, a correct diagnosis is essential to appropriate management. Radiologically these lesions are single, round, discrete lesions without the spiculations of primary malignancies. Fine needle aspiration biopsy (FNAB) may provide a definitive diagnosis, thereby sparing patients unnecessary surgery. Seventeen cases of nonmammary malignancies diagnosed by fine needle aspiration of the breast were identified in the cytopathology files at three different institutions from 1989 to 1999. Three of the cases are of particular interest, including a mucoepidermoid carcinoma of salivary gland origin and a small cell undifferentiated carcinoma of rectal origin, neither of which has been reported in the literature previously. The third case was a male with a breast mass that was originally thought to be primary based on clinical, cytologic and immunocytochemical features but subsequently was determined to be a metastasis from the lung. Virtually any malignancy may metastasize to the breast. FNAB is the best approach to the diagnosis of tumors that either clinically or radiographically are not typical of primary breast tumors. Extramammary neoplasms metastatic to the breast may be definitively diagnosed by FNAB, resulting in the most appropriate as well as cost-effective patient management.

  8. Movement control during aspiration with different injection systems via video monitoring-an in vitro model.

    PubMed

    Kämmerer, P W; Schneider, D; Pacyna, A A; Daubländer, M

    2017-01-01

    The aim of the present study was an evaluation of movement during double aspiration by different manual syringes and one computer-controlled local anesthesia delivery system (C-CLAD). With five different devices (two disposable syringes (2, 5 ml), two aspirating syringes (active, passive), one C-CLAD), simulation of double aspiration in a phantom model was conducted. Two experienced and two inexperienced test persons carried out double aspiration with the injection systems at the right and left phantom mandibles in three different inclination angles (n = 24 × 5 × 2 for each system). 3D divergences of the needle between aspiration procedures (mm) were measured with two video cameras. An average movement for the 2-ml disposal syringe of 2.85 mm (SD 1.63), for the 5 ml syringe of 2.36 mm (SD 0.86), for the active-aspirating syringe of 2.45 mm (SD 0.9), for the passive-aspirating syringe of 2.01 mm (SD 0.7), and for the C-CLAD, an average movement of 0.91 mm (SD 0.63) was seen. The movement was significantly less for the C-CLAD compared to the other systems (p < 0.001). The movement of the needle in the soft tissue was significantly less for the C-CLAD compared to the other systems (p < 0.001). A difference in involuntary movement of the syringe could be seen in comparison between manual and C-CLAD systems. Launching the aspiration by a foot pedal in computer-assisted anesthesia leads to a minor movement. To solve the problem of movement during aspiration with possibly increased false-negative results, a C-CLAD seems to be favorable.

  9. Fine-needle aspiration cytology of hemangiopericytoma: report of two cases.

    PubMed

    Sawh, R N; Lele, S M; Borkowski, J; Ventura, K C; Zaharopoulos, P; Logroño, R

    2000-09-01

    The fine-needle aspiration biopsy (FNAB) findings in two cases of hemangiopericytoma (HP), arising in the parotid gland and on the inner chest wall, respectively, are reported. Smear preparations in each case showed cytologic features of an undifferentiated spindle-cell neoplasm, whereas a core needle biopsy specimen of the chest wall mass showed a spindle-cell tumor with a "staghorn-like" arrangement of endothelium-lined vascular channels. Immunostains performed on this core biopsy, and on the surgical resection specimens in both cases, showed positive staining of tumor cells for vimentin and CD34, with negative staining for a variety of smooth muscle, epithelial, neural, and neuroendocrine markers. Electron microscopy performed in one case further supported the diagnosis of HP. With adequate sampling and appropriate use of ancillary studies, a diagnosis of HP can be reliably suggested on the basis of FNAB and core biopsy of a soft-tissue mass. Copyright 2000 Wiley-Liss, Inc.

  10. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  11. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  12. "Artificial lymphatic system": a new approach to reduce interstitial hypertension and increase blood flow, pH and pO2 in solid tumors.

    PubMed

    DiResta, G R; Lee, J; Healey, J H; Levchenko, A; Larson, S M; Arbit, E

    2000-05-01

    A mechanical drainage system, the "artificial lymphatic system" (ALS), consisting of a vacuum source and drain, is evaluated for its ability to aspirate the interstitial fluids responsible for the elevated interstitial fluid pressure (IFP) observed in solid tumors. IFP, pH, and pO2 radial profiles were measured before and after aspiration using wick-in-needle (WIN) probes, needle pH and oxygen electrodes, respectively. Laser Doppler flowmetry measured temporal changes in blood flow rate (BFR) at the tumor surface during aspiration. The WIN probe and IFP profile data were analyzed using numerical simulation and distributed mathematical models, respectively. The model parameter, P(E), reflecting central tumor IFP, was reduced from 15.3 to 5.7 mm Hg in neuroblastoma and from 13.3 to 12.1 mm Hg in Walker 256, respectively, following aspiration. The simulation demonstrated that spatial averaging inherent in WIN measurements reduced the calculated magnitude of the model parameter changes. IFP was significantly lower (p<0.05), especially in regions surrounding the drain, and BFR was significantly higher (p<0.05) following 25 and 45 min of aspiration, respectively; pH and pO2 profiles increased following aspiration. The experimental and mathematical findings suggest that ALS aspiration may be a viable way of reducing IFP and increasing BFR, pO2, and pH and should enhance solid tumor chemo and radiation therapy.

  13. Rare pancreatic neoplasms: the utility of endoscopic ultrasound-guided fine-needle aspiration-a large single center study.

    PubMed

    Imaoka, Hiroshi; Yamao, Kenji; Bhatia, Vikram; Shimizu, Yasuhiro; Yatabe, Yasushi; Koshikawa, Takashi; Kinoshita, Yoshikazu

    2009-01-01

    Tumors other than ductal adenocarcinomas constitute 10%-15% of all pancreatic tumors. We describe the performance and pitfalls of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of these rare pancreatic tumors and their characteristic cytopathological features. The records of 455 pancreatic fine-needle aspiration procedures done between March 1997 and August 2006 at Aichi Cancer Center, Nagoya, Japan, were reviewed. Besides cytology, aspirated material was routinely submitted in formalin for cell-block analysis. The reference standard for final diagnosis was surgical pathology from resected specimens. Twenty-eight rare (nonductal adenocarcinomas) pancreatic tumors were identified. Overall, EUS-FNA with the results of cytology, cell-block processing, and immunohistochemistry could correctly diagnose the type of neoplasm in 19 (67.9%) cases. EUS-FNA could distinguish benign from malignant rare tumors with a sensitivity of 69.2%, a specificity of 100%, positive predictive value of 100%, negative predictive value of 79.0%, and accuracy of 85.7%. None of three malignant pancreatic endocrine neoplasms could be diagnosed as malignant. An adequate core tissue sample could be obtained in 21 cases (75.0%) and provide a histopathological diagnosis in 19 (67.9%) cases. EUS-FNA could change the presumptive diagnosis in 11 (39.3%) cases. Specific immunochemical studies were useful adjuncts to the diagnosis. No major or minor complication was noted in any patient. Pancreatic neoplasms other than ductal adenocarcinomas have diverse imaging and histopathological features. EUS-FNA is accurate and safe for their identification.

  14. Fine Needle Aspiration

    MedlinePlus

    ... Programs Professional Development Home AcademyU Home Study Course Maintenance of Certification Conferences & Events Practice Management Home Resources Quality Clinical Data Registry Research Reimbursement ...

  15. Success rate of repeated fine needle aspiration biopsy of clinically suspicious thyroid nodules.

    PubMed

    Nagarajah, J; Farahati, J; Görges, R; Grabellus, F; Bockisch, A; Sheu-Grabellus, S-Y

    2012-01-01

    In this study we evaluated the success rate of double fine needle aspiration biopsy (FNAB) of clinically suspicious thyroid nodules in one session. The success rate of FNAB in clinical setting is quite low. There were several attempts made to improve the success rate of this method. It is anticipated that a double FNAB in one session would increase the success rate of FNAB. 176 consecutive patients (130 women, 46 men; mean age 56 years ± 11) with at least one clinically suspicious nodule were included in this study. Each individual nodule was biopsied twice (20G- and 21G-needle). In 33 patients, two suspicious nodules were biopsied, accounting for a total of 209 biopsied thyroid nodules. To evaluate the success rate the number of cell formations and the total number of cells in each cell formation were counted. The biopsy with the 20G needle provided in mean 40 cell cluster with a mean of 830 cells whereas the 21G needle provided in mean 41 cell cluster with a mean of 1010 cells. With the 20G needle the success rate was 73%, with the 21G needle 78% and the combination of the both biopsies provided a success rate of 87% (p = 0.01). Based on the number of cell formations and the total number of cells, the difference between the two needle sizes was not significant (p = 0.5 for cell formations and p = 0.9 for the total number of cells, respectively). A double FNAB of suspicious thyroid nodules in one session provides a higher success rate, and a 21G needle is sufficient enough.

  16. Acquired toxoplasmosis of a submandibular lymph node in a 9-year-old boy diagnosed by fine-needle aspiration cytology.

    PubMed

    Macey-Dare, L V; Kocjan, G; Goodman, J R

    1996-12-01

    Toxoplasmosis is a parasitic infection which may be asymptomatic or produce lymphadenopathy, fever and malaise. In children the cervical lymph nodes are most commonly affected. This report describes a case of a 9-year-old boy who presented with submandibular lymphadenopathy associated with a non-vital primary tooth, which persisted following extraction of the tooth. A diagnosis of acquired toxoplasmosis was made on the findings of fine-needle aspiration cytology and subsequently confirmed by serological investigations, thus sparing the patient unnecessary hospitalization and surgery. The patient required amitryptyline as a nocturnal sedative and made a complete recovery within a few months without the need for further intervention.

  17. Isolated splenic tuberculosis diagnosed by endoscopic ultrasound-guided fine needle aspiration.

    PubMed

    Nasa, Mukesh; Choudhary, Narendra S; Guleria, Mridula; Puri, Rajesh

    2017-04-01

    Our patient was a 48-year-old female, who presented with history of persistent low-grade fever and weight loss. The CT scan of the abdomen revealed multiple hypodense lesions in spleen. No primary focus of infection was detected in any other organs. Endoscopic ultrasound-guided fine needle aspiration of splenic lesion revealed granulomatous inflammation. The patient was started on anti-tuberculous therapy. There is a diagnostic possibility of splenic tuberculosis even in immunocompetent individuals and we chose a combination anti-tuberculous therapy as the first line treatment with consideration of splenectomy depending on the response. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  18. [Nonsurgical therapy of abdominal and retroperitoneal abscesses].

    PubMed

    Reuss, J A; Seitz, K

    1987-06-01

    From 1976 to March 1987 intraabdominal or retroperitoneal abscesses were confirmed by ultrasound in 40 patients. 13 patients had surgical drainage with zero-mortality. 3 of 27 patients were treated with antibiotics (only systemically). 24 patients were treated by percutaneous catheter drainage or needle aspiration. Elective cholecystectomy was performed later in 3 patients. Nonsurgical treatment was successful in 22/27 cases. 3 patients died despite percutaneous drainage. Failure of percutaneous drainage required surgical intervention in 3 patients. The considerably poorer primary condition of the patients receiving nonsurgical treatment allows no comparison with the surgical group. Advantages of percutaneous drainage and needle aspiration are a high success rate and low mortality. These techniques can be used even in critically ill persons.

  19. A Novel Method of Diagnosing Aberrant Pancreas: Needle-based Confocal Laser Endomicroscopy.

    PubMed

    Yasuda, Muneji; Hara, Kazuo; Kurita, Yusuke; Tanaka, Hiroki; Obata, Masahiro; Kuraoka, Naosuke; Matsumoto, Shimpei; Ito, Ayako; Iwaya, Hiromichi; Toriyama, Kazuhiro; Okuno, Nozomi; Kuwahara, Takamichi; Hijioka, Susumu; Mizuno, Nobumasa; Onishi, Sachiyo; Hirayama, Yutaka; Ishihara, Makoto; Tanaka, Tsutomu; Tajika, Masahiro; Niwa, Yasumasa

    2018-05-18

    Aberrant pancreas is defined as pancreatic tissue present outside of the pancreas and is often found incidentally during esophagogastroduodenoscopy. Obtaining sufficient tissue to differentiate aberrant pancreas from other subepithelial lesions is sometimes difficult. Due to the lack of a definitive diagnosis, patients often undergo unnecessary surgery. We herein report the first case of aberrant pancreas in which the concomitant use of needle-based probe confocal laser endomicroscopy and fine-needle aspiration supported the final diagnosis. Needle-based probe confocal laser endomicroscopy provides a real-time in vivo histopathology evaluation and may be a feasible means of diagnosing aberrant pancreas.

  20. Coring: a potential problem in eye surgery.

    PubMed

    Stein, H A; Vu, B L

    1994-03-01

    Any needle passing through a rubber stopper can aspirate a core of rubber. This rubber may then be injected into the eye or into the retrobulbar or peribulbar space. Aspirates from a number of syringes were spun down in a centrifuge and examined for microscopic particles. All specimens contained microscopic particles even from half-used bottles of Xylocaine.

  1. Fine needle aspiration of toxoplasmic lymphadenitis in an intramammary lymph node. A case report.

    PubMed

    Shimizu, K; Ito, I; Sasaki, H; Takada, E; Sunagawa, M; Masawa, N

    2001-01-01

    Cytologic findings of toxoplasmic lymphadenitis (TL) have been only sporadically reported. Intramammary lymph node is an extremely rare site for TL. A 47-year-old, healthy, female presented with a breast tumor, which was aspirated. The cytomorphologic features were interpreted as suggestive of TL. Histopathology of the excisional biopsy specimen and subsequent serologic examination confirmed the diagnosis. We obtained several characteristic findings in aspiration of TL. Of these, epithelioid cell clusters and monocytoid cells were the most diagnostic.

  2. A correlation study of diagnostic fine-needle aspiration with histologic diagnosis in cystic neck lesions.

    PubMed

    Moatamed, Neda A; Naini, Bita V; Fathizadeh, Payman; Estrella, Julie; Apple, Sophia K

    2009-10-01

    The clinical diagnosis of a mass in the neck region encompasses a wide spectrum of differential diagnosis. Fine-needle aspiration is a quick and safe technique, which can provide useful information for initial assessment and further therapeutic measures. The aim of this retrospective study was to evaluate the performance characteristics of the fine-needle aspiration (FNA) in cystic neck lesions. Of 142 patients with FNA for cystic neck masses during 2002-2007, 92 cases were selected with a follow-up histologic diagnosis, excluding the cystic colloid nodule of the thyroid. The cases were divided into salivary gland cystic neck (37 patients) and non-salivary cystic neck (55 patients) mass groups. False-positive and false-negative diagnoses were applied only to the malignant lesions after confirmation by histopathology. In the first group, nine malignant and 28 benign diagnoses were made by FNA; of which three were false-negative. In the second group, there were nine malignant and 46 benign diagnoses with three false negatives. The overall performance of the FNA showed 76% sensitivity and 100% specificity. In conclusion, FNA of the cystic neck lesions offers an invaluable and highly specific initial diagnostic approach for the management of the patients. (c) 2009 Wiley-Liss, Inc.

  3. Role of Fine Needle Aspiration Cytology in the Diagnosis of Skin and Superficial Soft Tissue Lesions: A Study of 510 Cases.

    PubMed

    Bhowmik, Abhijit; Mallick Sinha, Mamata Guha; Barman, Dilip Chandra

    2015-01-01

    Diseases of the skin and superficial subcutaneous soft tissues present with a wide array of lesions ranging from nonspecific dermatoses and inflammatory lesions to frank neoplasms. Though cytopathology is an excellent diagnostic tool in routine dermatologic practice, studies relating to histopathological and cytological correlation are sparse. The aim of this study was to analyze the concordance rate between cytological and histopathological diagnosis of skin and superficial soft tissue lesions. We retrospectively studied 510 consecutive fine needle aspiration cytology findings of cases from North Bengal Medical College and Hospital and correlated their diagnoses based upon cytological and histopathological grounds. Out of the 510 cases studied, 253 were non neoplastic lesions and 257 were neoplastic. A high degree of concordance was observed (100% for malignant and 96.15% for benign lesions) when these two diagnostic modalities were compared. Histopathological correlation was possible in all malignant, 52/189 (27.51%) of benign and 27/253 (10.67%) of non-neoplastic lesions. Sensitivity and specificity of diagnoses were 95.31% and 97.6%, respectively. It can be safely concluded that fine needle aspiration cytology is a rapid, reliable and fairly accurate tool for initial triage and treatment of skin and superficial soft tissue lesions.

  4. A Dual Wedge Microneedle for sampling of perilymph solution via round window membrane

    PubMed Central

    Watanabe, Hirobumi; Cardoso, Luis; Lalwani, Anil K.; Kysar, Jeffrey W.

    2017-01-01

    Objective Precision medicine for inner-ear disease is hampered by the absence of a methodology to sample inner-ear fluid atraumatically. The round window membrane (RWM) is an attractive portal for accessing cochlear fluids as it heals spontaneously. In this study, we report on the development of a microneedle for perilymph sampling that minimizes size of RWM perforation, facilitates quick aspiration, and provides precise volume control. Methods Considering the mechanical anisotropy of the RWM and hydrodynamics through a microneedle, a 31G stainless steel pipe was machined into wedge-shaped design via electrical discharge machining. Guinea pig RWM was penetrated in vitro, and 1 μ1 of perilymph was sampled and analyzed via UV-vis spectroscopy. Results The prototype wedge shaped needle created oval perforation with minor and major diameter of 143 and 344 μm (n=6). The sampling duration and standard deviation of aspirated volume were seconds and 6.8% respectively. The protein concentration was 1.74 mg/mL. Conclusion The prototype needle facilitated precise perforation of RWMs and rapid aspiration of cochlear fluid with precise volume control. The needle design is promising and requires testing in human cadaveric temporal bone and further optimization to become clinically viable. PMID:26888440

  5. Fine Needle Aspiration

    MedlinePlus

    ... Humanitarian Efforts International Outreach Advocacy Board of Governors Industry Programs Professional Development Home AcademyU Home Study Course Maintenance of Certification Conferences & Events Practice Management Home Resources ...

  6. An automated spring-loaded needle for endoscopic ultrasound-guided abdominal paracentesis in cancer patients

    PubMed Central

    Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa

    2014-01-01

    AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793

  7. The effect of body position on the 'hanging drop' method for identifying the extradural space in anaesthetized dogs.

    PubMed

    Naganobu, Kiyokazu; Hagio, Mitsuyoshi

    2007-01-01

    To assess the accuracy of the 'hanging drop method' for identifying the extradural space in anaesthetized dogs positioned in sternal or lateral recumbency. Prospective randomized-experimental study. Seventeen clinically healthy adult dogs, 10 females and seven males weighing 8.4-26.2 kg. Dogs were positioned in either sternal (n = 8) or lateral (n = 9) recumbency under general anaesthesia. A 20 SWG spinal needle pre-filled with 0.9% saline was advanced through the skin into the lumbosacral extradural space and the response of the saline drop recorded, i.e. whether it: 1) was aspirated from the hub into the needle; 2) remained within the hub, or 3) moved synchronously with i) spontaneous respiration, ii) heart beat or iii) manual lung inflation. The position of the needle tip was ultimately determined by positive contrast radiography. One dog positioned in lateral recumbency was excluded from the study because bleeding occurred from the needle hub. Saline was aspirated into the needle in seven of eight dogs held in sternal recumbency but in none of the dogs positioned in lateral recumbency. Accurate needle tip placement in the extradural space was confirmed by positive contrast radiography in all dogs. The 'hanging drop' method, when performed with a spinal needle, appears to be a useful technique for identifying the location of the extradural space in anaesthetized medium-sized dogs positioned in sternal, but not in lateral recumbency. The technique may yield 'false negative' results when performed in dogs positioned in sternal recumbency.

  8. Next-Generation Sequencing Identifies Gene Mutations That Are Predictive of Malignancy in Residual Needle Rinses Collected From Fine-Needle Aspirations of Thyroid Nodules.

    PubMed

    Fuller, Maren Y; Mody, Dina; Hull, April; Pepper, Kristi; Hendrickson, Heather; Olsen, Randall

    2018-02-01

    - Thyroid nodules have a prevalence of approximately 70% in adults. Fine-needle aspiration (FNA) is a minimally invasive, cost-effective, standard method to collect tissue from thyroid nodules for cytologic examination. However, approximately 15% of thyroid FNA specimens cannot be unambiguously diagnosed as benign or malignant. - To investigate whether clinically actionable data can be obtained using next-generation sequencing of residual needle rinse material. - A total of 24 residual needle rinse specimens with malignant (n = 6), indeterminate (n = 9), or benign (n = 9) thyroid FNA diagnoses were analyzed in our clinical molecular diagnostics laboratory using next-generation sequencing assays designed to detect gene mutations and translocations that commonly occur in thyroid cancer. Results were correlated with surgical diagnoses and clinical outcomes. - Interpretable data were generated from 23 of 24 residual needle rinse specimens. Consistent with its well-known role in thyroid malignancy, BRAF V600E mutations were detected in 4 malignant cases. An NRAS mutation was detected in 1 benign case. No mutations were detected from specimens with indeterminate diagnoses. - Our data demonstrate that residual thyroid FNA needle rinses are an adequate source of material for molecular diagnostic testing. Importantly, detection of a mutation implicated in thyroid malignancy was predictive of the final surgical diagnosis and clinical outcome. Our strategy to triage thyroid nodules with indeterminate cytology with molecular testing eliminates the need to perform additional FNA passes into dedicated media or to schedule additional invasive procedures. Further investigation with a larger sample size to confirm the clinical utility of our proposed strategy is underway.

  9. Endoscopic Ultrasound-Guided Fine Needle Aspiration: From the Past to the Future

    PubMed Central

    Costache, Mădălin-Ionuț; Iordache, Sevastița; Karstensen, John Gásdal; Săftoiu, Adrian; Vilmann, Peter

    2013-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a technique which allows the study of cells obtained through aspiration in different locations near the gastrointestinal tract. EUS-FNA is used to acquire tissue from mucosal/submucosal tumors, as well as peri-intestinal structures including lymph nodes, pancreas, adrenal gland, gallbladder, bile duct, liver, kidney, lung, etc. The pancreas and lymph nodes are still the most common organs targeted in EUS-FNA. The overall accuracy of EUS is superior to computed tomography scan and magnetic resonance imaging for detecting pancreatic lesions. In most cases it is possible to avoid unnecessary surgical interventions in advanced pancreatic cancer, and EUS is considered the preferred method for loco-regional staging of pancreatic cancer. FNA improved the sensitivity and specificity compared to EUS imaging alone in detection of malignant lymph nodes. The negative predictive value of EUS-FNA is relatively low. The presence of a cytopathologist during EUS-FNA improves the diagnostic yield, decreasing unsatisfactory samples or need for additional passes, and consequently the procedural time. The size of the needle is another factor that could modify the diagnostic accuracy of EUS-FNA. Even though the EUS-FNA technique started in early nineteen's, there are many remarkable progresses culminating nowadays with the discovery and performance of needle-based confocal laser endomicroscopy. Last, but not least, identification and quantification of potential molecular markers for pancreatic cancer on cellular samples obtained by EUS-FNA could be a promising approach for the diagnosis of solid pancreatic masses. PMID:24949369

  10. Tubercular thyroid abscess

    PubMed Central

    Kumar, Awanish; Pahwa, Harvinder Singh; Srivastava, Rohit; Khan, Khursheed Alam

    2013-01-01

    We encountered a patient who presented with neck swelling, difficulty in swallowing, voice change along with systemic features such as evening rise of temperature, chronic cough and weight loss. Ultrasonography of the thyroid gland revealed two cystic swellings. An ultrasound guided fine needle aspiration cytology was suggestive of tubercular abscess. The patient responded well to antigravity aspiration of the swellings and antitubercular treatment. PMID:23814203

  11. Cystic lesions of the salivary glands: cytologic features in fine-needle aspiration biopsies.

    PubMed

    Layfield, Lester J; Gopez, Evelyn V

    2002-10-01

    A variety of neoplastic and nonneoplastic lesions of the salivary glands have a predominantly cystic architecture. Fine-needle aspirates of these lesions yield watery or mucoid material, frequently of low cellularity. Such aspirates may be obtained from mucus retention cysts, lymphoepithelial cysts, cystadenomas, Warthin's tumors, cystic pleomorphic adenomas, low-grade mucoepidermoid carcinomas, cystadenocarcinomas, and examples of polycystic disease of the parotid gland. The cellular component within the fluid obtained from these lesions may be exceedingly scant or absent, making cytologic diagnosis difficult and, at times, impossible. We studied a series of 56 cystic lesions of the salivary glands, including 38 Warthin's tumors, 6 benign cysts, 2 lymphoepithelial cysts, 5 low-grade mucoepidermoid carcinomas, 1 cystic pleomorphic adenoma, 2 cystadenomas, and 2 cystadenocarcinomas. Careful attention to the cellular elements present often allowed definitive cytologic diagnosis, with an overall accuracy rate of 84%. The presence of atypical squamous metaplasia in oncocytic lesions was a significant cause of false-positive diagnoses of carcinoma (4 cases, 7%). Aspirates of low-grade mucoepidermoid carcinoma may contain no epithelial cells and result in false-negative diagnoses (1 case, 2%). Copyright 2002 Wiley-Liss, Inc.

  12. Fine needle aspiration cytology of parathyroid lesions.

    PubMed

    Heo, Ilyeong; Park, Sunhoo; Jung, Chang Won; Koh, Jae Soo; Lee, Seung-Sook; Seol, Hyesil; Choi, Hee Seung; Cho, Soo Youn

    2013-10-01

    There has been an increase in the use of fine needle aspiration cytology (FNAC) for the diagnosis of parathyroid lesions (PLs). Differentiation between a thyroid lesion and a PL is not easy because of their similar features. We reviewed parathyroid aspirates in our institution and aimed to uncover trends in diagnostic criteria. We selected 25 parathyroid aspirates (from 6 men and 19 women) confirmed surgically or immunohistochemically from 2006 to 2011. Major architectural findings of PLs include scattered naked nuclei, loose clusters, a papillary pattern with a fibrovascular core, tight clusters, and a follicular pattern. These architectures were commonly admixed with one another. Cytological features included anisokaryosis, stippled chromatin, a well-defined cell border, and oxyphilic cytoplasm. Eighteen of the 25 patients were diagnosed with PL using FNAC. Seven patients had been misdiagnosed with atypical cells (n=2), benign follicular cells (n=2), adenomatous goiter (n=2) and metastatic carcinoma (n=1) in FNAC. Using clinicoradiologic data, the sensitivity of the cytological diagnosis was 86.7%. The cytological sensitivity decreased to 50% without this information. FNAC of PL is easily confused with thyroid lesions. A combination of cytological parameters and clinical data will be required to improve the diagnostic sensitivity of PLs.

  13. Three-dimensional cytomorphology in fine needle aspiration biopsy of medullary thyroid carcinoma.

    PubMed

    Chang, T C; Lai, S M; Wen, C Y; Hsiao, Y L; Huang, S H

    2001-01-01

    To elucidate three-dimensional (3-D) cytomorphology in fine needle aspiration biopsy (FNAB) of medullary thyroid carcinoma (MTC). ENAB was performed on tumors from five patients with MTC. The aspirate was stained and observed under a light microscope (LM). The aspirate was also fixed, dehydrated, critical point dried, spattered with gold ions and observed with a scanning electron microscope (SEM). For transmission electron microscopy (TEM), the specimen was fixed, dehydrated, embedded in an Epon mixture, cut with an ultramicrotome, mounted on copper grids, electron doubly stained with uranium acetate and lead citrate, and observed with TEM. Findings under SEM were correlated with those under LM and TEM. Under SEM, 3-D cytomorphology of MTC displayed a disorganized cellular arrangement with indistinct cell borders in three cases. The cell surface was uneven and had granular protrusions that corresponded to secretory granules observed under TEM. In one case with multiple endocrine neoplasia type IIB, there were abundant granules on the cell surface. In one case of sporadic MTC with multinucleated tumor giant cells and small cells, granular protrusions also were noted on the cell surface. Granular protrusion was a characteristic finding in FNAB of MTC tinder SEM and might be helpful in the differential diagnosis.

  14. Fine needle aspiration cytology of granulomatous mastitis with special emphasis on microbiologic correlation.

    PubMed

    Nemenqani, Dalal; Yaqoob, Nausheen; Hafiz, Momein

    2009-01-01

    To describe the cytomorphology of granulomatous mastitis (GM) and to evaluate the causative agents involved, proven on the basis of microbiologic culture results and polymerase chain reaction (PCR) studies. We retrospectively reviewed the inflammatory breast aspirates reported at King Abdul Aziz Specialist Hospital and Al Hada Armed Forces Hospital, Taif, Kingdom of Saudi Arabia, from January 2000 until March 2008. The pathology reports, clinical information, slides, microbiologic culture results and tuberculosis (TB)/PCR were reviewed. Cases of inflammatory carcinoma or duct ectasia were excluded. A total of 49 cases of inflammatory breast aspirates were identified, of which 15 cases were GM. The microbiologic cultures of all 15 cases were available. Six of 15 cases had positive culture for Brucella melitenses, and 2 cases were positive for TB, which was further confirmed by TB/PCR. The fungal cultures were negative in all the cases. Seven of 15 cases were classified as idiopathic GM. Fine needle aspiration cytology was found to be a useful tool in the early diagnosis of GM and its classification if performed by a pathologist as the material can be submitted for culture. The definitive diagnosis can be established by a combination of the cytomorphologic features and microbiologic studies.

  15. Cysticercosis: Hooked by a Hooklet on Fine Needle Aspiration Cytology—A Case Report

    PubMed Central

    Sawhney, Manav; Agarwal, Shubhra

    2013-01-01

    Cysticercosis is a systemic parasitic disease caused by the larval form of cestode T. solium. It has a worldwide distribution and is potentially harmful with variable clinical manifestations. The patient most commonly presents with subcutaneous and muscle involvement in the form of nodular lesions. The other most commonly involved sites include eye, brain, bladder wall, and heart. Cysticercosis can be diagnosed on serology, and radiologically but confirmatory diagnosis is based on histopathological examination of the involved tissue biopsy specimen. Fine needle aspiration cytology is a useful low-cost outpatient procedure tool for preoperative diagnosis of cysticercosis and is absolutely essential for diagnosis of the parasitic lesions in a peripheral hospital, one like ours. PMID:24024052

  16. Hyalinizing Trabecular Tumor of the Thyroid Gland, a Diagnostic Challenge in Fine-Needle Aspiration Cytology: Case Report.

    PubMed

    Rhee, Ye-Young; Jung, Hong Kyu; Kim, Se Hoon; Kim, Soo Hee

    2018-06-11

    Hyalinizing trabecular tumor (HTT) is a rare thyroid tumor with low to minimal malignant potential. HTT is often misinterpreted as other thyroid tumors, including papillary thyroid carcinoma (PTC) and medullary thyroid carcinoma (MTC), on fine-needle aspiration (FNA) cytology, because of its overlapping cytologic features, such as nuclear grooves and intranulcear pseudoinclusions. Although cytopathologists cannot definitely conclude HTT by FNA cytology, suspicion of HTT is necessary to avoid misdiagnosing HTT as PTC or MTC and to avoid unnecessary aggressive treatment. Here, we report a case of HTT with novel cytologic features in CellPrep liquid based cytology that was diagnosed as suspicious for papillary carcinoma by FNA and finally diagnosed as HTT in the surgical specimen.

  17. Is there still a role for thyroid scintigraphy in the workup of a thyroid nodule in the era of fine needle aspiration cytology and molecular testing?

    PubMed Central

    Moreno-Reyes, Rodrigo; Kyrilli, Aglaia; Lytrivi, Maria; Bourmorck, Carole; Chami, Rayan; Corvilain, Bernard

    2016-01-01

    Thyroid scintigraphy is now rarely used in the work-up of a thyroid nodule except in the presence of a low TSH value. Therefore, autonomously functioning thyroid nodules (AFTNs) with a normal TSH value are diagnosed only in the rare medical centers that continue to use thyroid scan systematically in the presence of a thyroid nodule. In this review, we discuss the prevalence of AFTN with a normal TSH level and the possible consequences of performing fine needle aspiration cytology (FNAC) in an undiagnosed AFTN. We also discuss the risk of malignant AFTN which may be higher than previously stated. PMID:27158470

  18. Elementary Students Using a Tablet-Based Note-Taking Application in the Science Classroom

    ERIC Educational Resources Information Center

    Paek, Seungoh; Fulton, Lori A.

    2016-01-01

    This exploratory study investigates the potential of a tablet-based note-taking application (TbNA) to serve as a digital notebook in support of students' classroom science practices. An elementary teacher (Grades 4-5) from a public charter school integrated a TbNA into her science class for one semester while participating in professional…

  19. Fine needle aspiration cytology of breast cancer in women aged 70 years and older.

    PubMed

    Tse, Gary M K; Somali, Anjali; Chan, Anthony W H; Chaiwun, Benjaporn; Lui, Philip C W; Moriya, Takuya; Hwang, Jacqueline S G; Chan, Norman H L; Tan, Puay Hoon

    2008-10-01

    Elderly breast cancers are associated with a more favourable biological marker profile and higher proportion of specific subtypes, some of which are of low histological grade. We reviewed the fine needle aspiration cytology (FNAC) to assess the cytological characteristics and any clues to assist in the diagnosis. The aspirates of 140 cancers of various histological types and grades and 39 benign lesions were evaluated for 13 cytological parameters including cellularity of the direct and cytospin smears, epithelial cell clusters, cellular atypism, cytoplasmic features, vacuoles, mitotic figures, presence of myoepithelial cells, single background epithelial cells, the presence of naked nuclei, stromal fragments and necrosis. We found that the presence of background single epithelial cells, atypism of such cells, absence of benign appearing epithelial fragments, nuclear atypism of the epithelial cells within the fragments, presence of moderate amount of cytoplasm of these cells, absence of myoepithelial cells within the cluster, and absence of bipolar nuclei in the background have a strong association with malignancy. Scoring only the presence of single cells in the background, single cell atypism and the absence of bipolar nuclei in a scoring system can differentiate between benign and malignant aspirates with high (>90%) sensitivity and specificity. Assessing the presence of single cells in the background, single cell atypism and the absence of bipolar nuclei facilitates identification of malignancy in the aspiration of breast lesions from elderly patients.

  20. Metastasis of colon cancer to the thyroid gland: a case diagnosed on fine-needle aspirate by a combined cytological, immunocytochemical, and molecular approach.

    PubMed

    Cozzolino, Immacolata; Malapelle, Umberto; Carlomagno, Chiara; Palombini, Lucio; Troncone, Giancarlo

    2010-12-01

    Fine-needle aspiration (FNA) with cytological evaluation reliably diagnoses primary and secondary thyroid neoplasms. However, identifying the primary origin of a metastatic process involving the thyroid gland is challenging. In particular, metastasis of colon cancer to the thyroid gland is very rare. In this case report, a right lobe solid thyroid nodule in a 66-year-old male was aspirated. FNA cytology showed necrosis and atypical tall columnar cells; since, the patient at age 60 had undergone surgery for a sigmoid-rectal cancer metastasizing to the liver and subsequently to the lung, a suspicion of metastasis from colon cancer was raised. This was corroborated by cell-block immunocytochemistry showing a cytokeratin (CK) 7 negative/CK20-positive staining pattern; thyreoglobulin and TTF-1 were both negative. Since KRAS codon 12/13 mutations frequently occur in colon cancer, whereas they are extremely uncommon in primary thyroid tumors, DNA was extracted from the aspirated cells, and KRAS mutational analysis was carried out. The codon 12 G12D mutation was found; the same mutation was evident in the primary cancer of the colon and in its liver and lung metastasis. Thus, a combined cytological, immunocytochemical and molecular approach unquestionably correlated metastatic adenocarcinoma cells aspirated from the thyroid to a colo-rectal origin. © 2010 Wiley-Liss, Inc.

  1. THE RESULTS OF PARATHYROID HORMONE ASSAY IN PARATHYROID ASPIRATES IN PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMAS FOR FOCUSED PARATHYROIDECTOMY IN PATIENTS WITH NEGATIVE OR SUSPICIOUS TECHNETIUM-99M-SESTAMIBI SCANS.

    PubMed

    Ozderya, Aysenur; Temizkan, Sule; Cetin, Kenan; Ozugur, Sule; Gul, Aylin Ege; Aydin, Kadriye

    2017-09-01

    This study aimed to evaluate the results of parathyroid hormone (PTH) assay in parathyroid aspirates to determine uniglandular disease by an endocrinologist-performed ultrasound (US) in patients with discordant or negative technetium-sestamibi scans and to evaluate whether this procedure increases the number of focused parathyroidectomies (FPs). We analyzed the data of 65 patients who underwent an endocrinologist-performed US-guided parathyroid fine-needle aspiration (FNA) with PTH wash-out, retrospectively. The results of PTH wash-out procedure and the reports of parathyroid surgery and pathology were reviewed. Of 65 patients, 54 had positive PTH wash-out results. The median serum PTH level of patients with positive and negative PTH wash-out results was 143 (25 and 75% interquartile range [IQR], 114 to 197) versus 154 (IQR, 115 to 255) pg/mL (P = .45), and the median PTH in FNA was 3,533 (IQR, 1,481 to 3,534) versus 6.0 (IQR, 1 to 6) pg/mL (P<.001), respectively. Forty-five patients underwent surgery. Of the operated patients, 42 had positive PTH wash-out results and had successful FP. Four patients with redo surgery had positive PTH wash-out results and were successfully re-operated with FP. Of 11 patients with negative PTH wash-out results, 3 had bilateral neck exploration (BNE) surgery and 2 patients were successfully operated, while surgery was unsuccessful in 1 patient, despite BNE. Our study results suggest that endocrinologist-performed US and parathyroid FNA with PTH wash-out increases the number and success of FPs. In particular, patients with redo surgery may benefit from this procedure. 4D-CT = four-dimensional computed tomography BNE = bilateral neck exploration FNA = fine-needle aspiration FNAB = fine-needle aspiration biopsy FP = focused parathyroidectomy IQR = 25 and 75% inter-quartile range PHPT = primary hyperparathyroidism PPV = positive predictive value PTH = parathyroid hormone 99m Tc = technetium US = ultrasound.

  2. Diagnostic accuracy of fine-needle aspiration cytology of thyroid gland lesions: A study of 200 cases in Himalayan belt.

    PubMed

    Sharma, Reetika; Verma, Neelam; Kaushal, Vijay; Sharma, Dev Raj; Sharma, Dhruv

    2017-01-01

    The study is undertaken to correlate the fine-needle aspiration cytology (FNAC) findings with histopathology in a spectrum of thyroid lesions and to find the diagnostic accuracy of fine-needle aspiration (FNA) so that unnecessary thyroidectomies can be avoided in benign lesions. This study was carried out over the period of 1-year (May 1, 2012-April, 30 2013). FNA specimens obtained from 200 patients were analyzed. Of these, only 40 patients underwent surgery and their thyroid specimens were subjected to histopathological examination. The age of the patients ranged from 9 to 82 years with mean age being 43 years. There was female preponderance, with male to female ratio being 1:7. On cytology out of 200 cases, 148 (74%) were benign, 25 (12.5%) were malignant, 16 (8%) were indeterminate, and 11 (5.5%) were nondiagnostic. Only 40 patients underwent surgery. On histopathology, 21 (52.5%) cases were benign and 19 (47.5%) were malignant. The statistical analysis of cytohistological correlation for both benign and malignant lesions revealed sensitivity, specificity, and diagnostic accuracy of 84%, 100% and 90%, respectively. FNAC is a minimally invasive, highly accurate and cost-effective procedure for the assessment of patients with thyroid lesions and has high -sensitivity and specificity. It acts as a good screening test and avoids unnecessary thyroidectomies.

  3. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    PubMed

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  4. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    PubMed

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  5. The value of the repeated examination of BRAF V600E mutation status in diagnostics of papillary thyroid cancer.

    PubMed

    Beiša, Augustas; Beiša, Virgilijus; Stoškus, Mindaugas; Ostanevičiūtė, Elvyra; Griškevičius, Laimonas; Strupas, Kęstutis

    2016-01-01

    Nodular thyroid disease is one of the most frequently diagnosed pathologies of the adult population in iodine-deficient regions. Approximately 30% of thyroid aspirates are classified as nondiagnostic/unsatisfactory or indeterminate. However, patients with indeterminate cytology still undergo surgery. The object of this study was to determine the diagnostic value of re-examining the BRAF V600E mutation in papillary thyroid carcinoma patients. All patients underwent ultrasound guided fine-needle aspiration of a thyroid nodule. They were assigned to one of the four groups (indeterminate or positive for malignant cells) of the Bethesda System for Reporting Thyroid Cytopathology. Genetic investigation of the BRAF V600E mutation was performed for all of the fine-needle aspiration cytology specimens. All of the patients underwent surgery. Subsequently, histological investigation of the removed tissues was performed. Additional analysis of the BRAF V600E mutation from the histology specimen was then performed for the initially BRAF-negative cases. Two hundred and fourteen patients were involved in the study. One hundred and six (49.53%) patients were diagnosed with thyroid cancer. Of these 106 patients, 95 (89.62%) patients were diagnosed with papillary thyroid cancer. The BRAF V600E mutation was positive in 62 (65.26%) and negative in 33 (34.74%) histologically confirmed papillary thyroid cancer cases. After the genetic investigation, a total of 74 (77.89%) papillary thyroid cancer cases were positive for the BRAF V600E mutation and 21 (22.11%) were negative. Repeated examination of the BRAF V600E mutation status in the fine-needle aspiration may potentially increase the sensitivity of papillary thyroid cancer diagnostics.

  6. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    PubMed Central

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  7. Acquired myospherulosis secondary to gluteal augmentation on fine needle aspiration cytology: A diagnostic challenge.

    PubMed

    Alperstein, Susan; Dilcher, Thomas; Viswanathan, Kartik; Rao, Rema A; Siddiqui, Momin T; Giorgadze, Tamara

    2018-05-01

    A 30-year-old female presented with a three-month history of a multilocular cystic lesion over the lumbosacral spine. Fine-needle aspiration biopsy (FNA) of the lesion was performed at an outside institution, and a cytologic diagnosis, suspicious for chordoma, was rendered. The patient presented for surgical consultation at our institution. Repeat FNA demonstrated an unusual fat-like material. Upon further inquiry, the patient provided a recent history of gluteal contour improvement with fibroadipose tissue implants. A diagnosis of myospherulosis was made with a concurrent surgical pathology correlation. No evidence of chordoma was identified. To date, this is the first reported case of acquired myospherulosis in the context of gluteal contour enhancement and represents an important diagnostic pitfall to consider on cytology preparations. © 2017 Wiley Periodicals, Inc.

  8. Fine needle aspiration cytology of hepatic metastasis from a meningeal hemangiopericytoma. A case report.

    PubMed

    Ghaffar, Hasan; Parwani, Anil; Rosenthal, Dorothy L

    2003-01-01

    Hemangiopericytomas (HPCs) are rare spindle cell tumors, constituting 2.5% of soft tissue neoplasms. Few reports have addressed the fine needle aspiration (FNA) cytology of HPC. We describe the FNA biopsy (FNAB) findings in a 44-year-old patient with a previously resected meningeal hemangiopericytoma. The patient underwent ultrasound-guided FNAB of a 16.0-cm, radiographically heterogeneous density in the liver. The FNA smear showed crowded, ovoid to spindle-shaped cells with poorly defined, scant cytoplasm. The neoplastic cells were positive for CD34 and negative for CD31, factor VIII, glial fibrillary acid protein and cytokeratin AE1/AE3, supporting a diagnosis of HPC and compatible with metastasis from the patient's cerebral tumor. This case documents the role of FNA cytology in confirming HPC.

  9. A comparison of Quincke and Whitacre needles with respect to risk of intravascular uptake in S1 transforaminal epidural steroid injections: a randomized trial of 1376 cases.

    PubMed

    Shin, Jaehyuck; Kim, Yong Chul; Lee, Sang Chul; Kim, Jae Hun

    2013-11-01

    Transforaminal epidural steroid injection (TFESI) is a useful treatment modality for pain management. Most complications of TFESI are minor and transient. However, there is a risk of serious complications such as nerve injury, spinal cord infarct, or paraplegia. Some of the risks are related to direct injury to the vessel or intravascular injection of the particulate steroid. We prospectively tested the hypothesis that the intravascular injection rate of the Whitacre needle is lower than that of the Quincke needle during TFESI. This study was a randomized trial of 1376 TFESIs at the S1 level. We collected data of age, gender, height, weight, laterality (right/left), history of lumbosacral spine operation, history of appropriate interval discontinuation of anticoagulation medicines, and underlying disease. During the S1 TFESI, intrasacral bone contact, a blood aspiration test, and real-time fluoroscopy of the intravascular injection using contrast media were investigated. There were no significant differences in the intravascular injection rate with respect to age, gender, height, weight, hypertension, diabetes mellitus, laterality, history of lumbosacral spine operation, or history of appropriate interval discontinuation of anticoagulation medicines. Intravascular injection was significantly associated with a blood aspiration test (P < 0.001), needle tip type (P = 0.002), intrasacral bone contact (P < 0.001), and physicians (some P < 0.05). The use of Quincke needles and intrasacral bone contact increased the rate of intravascular injection. To reduce the risk of intravascular injection, the use of Whitacre needles without intrasacral bone contact may be a safer and more effective approach.

  10. Randomized in vitro and in vivo evaluation of different biopsy needles and devices for breast biopsy.

    PubMed

    Helbich, T H; Rudas, M; Böhm, G; Huber, S; Wagner, T; Taucher, S; Wolf, G; Mostbeck, G H

    1999-01-01

    In an experimental study (in vitro and in vivo) we evaluated the efficacy of various biopsy needles/devices for breast biopsy. In vitro, biopsies of five human cadaveric breast specimens were performed using 33 different needles/devices ranging from 14 to 20-gauge. Of these 33 needles/devices, 22 optimally performing needles were selected for the in vivo study. In the clinical part of the study, 44 breast lesions were randomly biopsied with each of the 22 needles/devices under stereotactic guidance. Tissue specimens were analysed quantitatively and qualitatively. Several automatic long-throw guns (Acecut, Asap, Biopty, Magnum) obtained greater tissue areas and had a better histopathologic score than the conventional type of a side-notch needle like Trucut, an aspiration needle like Surecut, or an end-cut needle like Autovac. The automatic long-throw guns performed better than the short-throw Monopty gun. Regardless of needle size (14-20-gauge), breast biopsies should be routinely performed with automated long-throw side-notch guns (Acecut, Asap, Biopty, Magnum).

  11. Harris P. Mosher Award thesis. Peritonsillar abscess: incidence, current management practices, and a proposal for treatment guidelines.

    PubMed

    Herzon, F S

    1995-08-01

    Currently there is no agreement on the treatment of patients who develop a peritonsillar abscess (PTA). This lack of consensus results in highly variable and possibly expensive therapeutic regimens that may not provide optimum quality patient care at reasonable cost. The present study evaluates surgical, medical, diagnostic, and cost factors that affect the management of PTA based on the following: 1. a cohort study of 123 patients with PTA treated using needle aspiration as the initial surgical drainage; 2. a national survey of the PTA management practices of otolaryngologists; and 3. meta-analyses of various components of the treatment regimen for PTA. In the cohort study, patients diagnosed with PTA were treated by both otolaryngologists and emergency medicine specialists with needle aspiration as the primary surgical modality resulting in a 96% acute resolution rate for PTA. In the national survey, questionnaires were sent to 2000 randomly selected members of the American Academy of Otolaryngology-Head and Neck Surgery regarding their management of PTA. The return rate was 73%. Ninety-six percent of the physicians who returned survey forms treated an average of seven PTAs per year using either needle aspiration, incision and drainage, or abscess tonsillectomy to drain the abscess initially. The incidence of PTA in the United States and Puerto Rico among patients 5 to 59 years of age treated by survey practitioners is 30.1 per 100,000 person years, accounting for approximately 45,000 cases per year. Four meta-analyses were completed to quantify the success rate of needle aspiration in the treatment of PTA (94%), the recurrence rate of PTA (10% to 15%), the rate at which penicillin-resistant microorganisms are found in patients with PTA (0% to 56%), and the rate of prior oropharyngeal infections associated with PTA (11% to 56%). The recurrence rate for PTA in the United States is 10%, which is significantly different from the recurrence rate of 15% reported from the rest of the world (P < .002). A clinical intervention for PTA is proposed based on the clinical series, the national survey data, and the meta-analyses. These clinical guidelines recommend that needle aspiration be used as the initial surgical drainage procedure for all patients with a PTA other than those who have indications for abscess tonsillectomy. Patients should be treated in an outpatient setting, should receive penicillin if they are not allergic to it, and should receive adequate pain medication. The evidence does not suggest that there is any benefit in examining the abscess contents for microorganisms. Approximately 30% of patients with PTA can be expected to exhibit relative indications for a tonsillectomy.(ABSTRACT TRUNCATED AT 400 WORDS)

  12. To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions

    PubMed Central

    But, David Yiu-Kuen; Poley, Jan-Werner

    2014-01-01

    Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337

  13. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    PubMed

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  14. Retraction of the Plunger on a Syringe of Hyaluronic Acid Before Injection: Are We Safe?

    PubMed

    Carey, Wayne; Weinkle, Susan

    2015-12-01

    Controversy exists concerning the need for aspiration before injection with hyaluronic acid (HA) fillers. The authors undertook a study of HA products to determine if blood could be aspirated back into a syringe of HA when the needle has been primed or filled with HA. Two studies were set up to determine if or when blood could be withdrawn from a heparinized fresh tube of blood into the HA syringe. Two different techniques were tested; one using a slow-pull retraction of the plunger and up to a 5-second waiting time before release versus a rapid pullback and quick release. Review of these data demonstrates that the usual clinical method, which involves quick withdrawal and instant release of the syringe plunger does not allow for sufficient removal of the filler found intraluminal in the needle and may give rise to false negative results in vitro and likely in vivo with the exception being the Galderma/Medicis products. In summary, withdrawal of the syringe plunger with no visible blood in the syringe does not eliminate the possibility of intravascular placement of the syringe needle.

  15. IAC Standardized Reporting of Breast Fine-Needle Aspiration Biopsy Cytology.

    PubMed

    Field, Andrew S; Schmitt, Fernando; Vielh, Philippe

    2017-01-01

    There have been many changes in the roles of fine-needle aspiration biopsy (FNAB) and core needle biopsy (CNB) in the diagnostic workup of breast lesions in routine breast clinics and in mammographic breast screening programs, as well as changes in the management algorithms utilized and the treatments available, since the NCI consensus on breast FNAB cytology in 1996. A standardized approach will improve training and performance of FNAB and smear-making techniques, and structured reporting will improve the quality and reproducibility of reports across departments, cities and countries providing a basis for quality assurance measures and improving patient care and facilitating research. Linking cytology reports to management algorithms will increase the clinicians' use of FNAB cytology and where appropriate CNB, and enhance the use of ancillary tests for prognostic testing. The IAC recognizes that the local medical infrastructure and resources for breast imaging, biopsy and treatment will influence the diagnostic workup and management of breast disease, but best practice guidelines should be established and modified as required. © 2016 S. Karger AG, Basel.

  16. Malignant nodular hidradenoma on the scalp: report of a case with fine needle aspiration cytology features and histologic correlation.

    PubMed

    Garcia-Bonafe, María Magdalena; Campins, Maria M Company; Redecilla, Pere Huguet

    2009-01-01

    Malignant nodular hidradenoma (MNH) is a malignant adnexal tumor of the eccrine sweat glands. The histology is similar to that of benign nodular hidradenoma, but MNH shows an infiltrative and invasive pattern, necrosis and angiolymphatic invasion. A 60-year-old woman, diagnosed with rectal adenocarcinoma 6 months before, underwent fine needle aspiration (FNA) of a nodule on the scalp. The aspirate smears showed (1) necrotic debris; (2) cohesive cell clusters and tissue fragments; (3) tubular formations; (4) globoid or cylindrical clear cells; (5) cells showing dense cytoplasm and a basaloid appearance; (6) cell sheets with anaplasia and squamous differentiation; and (7) multinucleated giant cells. The histology showed a lobulated pattern with necrosis and cyst formation. The clear cells that were seen on cytology occupied the periphery of the lobules, whereas the anaplastic cells were located in the central portion. Squamous differentiation and tubular formations were observed. Rapid, accurate diagnosis of these tumors is important, particularly when they develop at sites where a metastatic process must be ruled out. Cytology of FNA material provides this capability.

  17. The value of fine needle aspiration cytology in the clinical management of rare salivary gland tumors

    PubMed Central

    Mezei, Tibor; Mocan, Simona; Ormenisan, Alina; Baróti, Beáta; Iacob, Alina

    2018-01-01

    Abstract Salivary gland tumors are relatively rare neoplasms, mostly located in the parotid gland, and few are malignant. Preoperative evaluation of salivary gland tumors includes fine needle aspiration cytology (FNAC). Objective The purpose of this study was to determine the importance of FNAC in the evaluation of rare salivary gland neoplasms. Material and Methods Four cases of rare salivary gland tumors were included, which were preoperatively assessed by clinical investigation, computed tomography, and FNAC. Results The presented cases include myoepithelial carcinoma, oncocytic carcinoma, undifferentiated lymphoepithelial carcinoma, and marginal zone lymphoma. Conclusion FNAC is a reliable diagnostic tool for common salivary gland neoplasms; however, rare tumors often represent diagnostic challenges. Clinical relevance In such rare tumors, the role of aspiration cytology may be limited to establishing the dignity of the lesion (benign/malignant). This knowledge enables the surgeon to choose the most appropriate therapeutic procedure. A definitive diagnosis of rare tumors (either epithelial or nonepithelial) is obtained by histological examination; cytology is limited in this regard due to overlapping features. PMID:29489937

  18. Development of a Novel Ultrasound-guided Peritonsillar Abscess Model for Simulation Training.

    PubMed

    Ng, Vivienne; Plitt, Jennifer; Biffar, David

    2018-01-01

    Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. This low-cost, easy-to-construct simulator allows for ultrasound image acquisition while performing PTA needle aspirations and is the first reported of its kind. Educators from EM and otolaryngology can use this model to educate inexperienced trainees, thus ultimately improving patient safety in the clinical setting.

  19. Core Needle Biopsy of the Thyroid: 2016 Consensus Statement and Recommendations from Korean Society of Thyroid Radiology

    PubMed Central

    Na, Dong Gyu; Jung, So Lyung; Kim, Ji-hoon; Sung, Jin Yong; Kim, Kyu Sun; Lee, Jeong Hyun; Shin, Jung Hee; Choi, Yoon Jung; Ha, Eun Ju; Lim, Hyun Kyung; Kim, Soo Jin; Hahn, Soo Yeon; Lee, Kwang Hwi; Choi, Young Jun; Youn, Inyoung; Kim, Young Joong; Ahn, Hye Shin; Ryu, Ji Hwa; Baek, Seon Mi; Sim, Jung Suk; Jung, Chan Kwon; Lee, Joon Hyung

    2017-01-01

    Core needle biopsy (CNB) has been suggested as a complementary diagnostic method to fine-needle aspiration in patients with thyroid nodules. Many recent CNB studies have suggested a more advanced role for CNB, but there are still no guidelines on its use. Therefore, the Task Force Committee of the Korean Society of Thyroid Radiology has developed the present consensus statement and recommendations for the role of CNB in the diagnosis of thyroid nodules. These recommendations are based on evidence from the current literature and expert consensus. PMID:28096731

  20. Cell-block procedure in endoscopic ultrasound-guided-fine-needle-aspiration of gastrointestinal solid neoplastic lesions

    PubMed Central

    Ieni, Antonio; Barresi, Valeria; Todaro, Paolo; Caruso, Rosario Alberto; Tuccari, Giovanni

    2015-01-01

    In the present review we have analyzed the clinical applications of endoscopic ultrasound-guided-fine-needle-aspiration (EUS-FNA) and the methodological aspects obtained by cell-block procedure (CBP) in the diagnostic approach to the gastrointestinal neoplastic pathology. CBP showed numerous advantages in comparison to the cytologic routine smears; in particular, better preservation of cell architecture, achievement of routine haematoxylin-eosin staining equivalent to histological slides and possibility to perform immunohistochemistry or molecular analyses represented the most evident reasons to choose this method. Moreover, by this approach, the differential diagnosis of solid gastrointestinal neoplasias may be more easily achieved and the background of contaminant non-neoplastic gastrointestinal avoided. Finally, biological samples collected by EUS-FNA CBP-assisted should be investigated in order to identify and quantify further potential molecular markers. PMID:26322154

  1. Reliable Gene Expression Measurements from Fine Needle Aspirates of Pancreatic Tumors

    PubMed Central

    Anderson, Michelle A.; Brenner, Dean E.; Scheiman, James M.; Simeone, Diane M.; Singh, Nalina; Sikora, Matthew J.; Zhao, Lili; Mertens, Amy N.; Rae, James M.

    2010-01-01

    Background and aims: Biomarker use for pancreatic cancer diagnosis has been impaired by a lack of samples suitable for reliable quantitative RT-PCR (qRT-PCR). Fine needle aspirates (FNAs) from pancreatic masses were studied to define potential causes of RNA degradation and develop methods for accurately measuring gene expression. Methods: Samples from 32 patients were studied. RNA degradation was assessed by using a multiplex PCR assay for varying lengths of glyceraldehyde-3-phosphate dehydrogenase, and effects on qRT-PCR were determined by using a 150-bp and a 80-bp amplicon for RPS6. Potential causes of and methods to circumvent RNA degradation were studied by using FNAs from a pancreatic cancer xenograft. Results: RNA extracted from pancreatic mass FNAs was extensively degraded. Fragmentation was related to needle bore diameter and could not be overcome by alterations in aspiration technique. Multiplex PCR for glyceraldehyde-3-phosphate dehydrogenase could distinguish samples that were suitable for qRT-PCR. The use of short PCR amplicons (<100 bp) provided reliable gene expression analysis from FNAs. When appropriate samples were used, the assay was highly reproducible for gene copy number with minimal (0.0003 or about 0.7% of total) variance. Conclusions: The degraded properties of endoscopic FNAs markedly affect the accuracy of gene expression measurements. Our novel approach to designate specimens “informative” for qRT-PCR allowed accurate molecular assessment for the diagnosis of pancreatic diseases. PMID:20709792

  2. Lymph node staging of oral and maxillofacial neoplasms in 31 dogs and cats.

    PubMed

    Herring, Erin S; Smith, Mark M; Robertson, John L

    2002-09-01

    A retrospective study was performed to report the histologic examination results of regional lymph nodes of dogs and cats with oral or maxillofacial neoplasms. Twenty-eight dogs and 3 cats were evaluated. Histologic examination results of standard and serial tissue sectioning of regional lymph nodes were recorded. When available, other clinical parameters including mandibular lymph node palpation, thoracic radiographs, and pre- and postoperative fine needle aspiration of lymph nodes were compared with the histologic results. Squamous cell carcinoma, fibrosarcoma, and melanoma were the most common neoplasms diagnosed in dogs. Squamous cell carcinoma and fibrosarcoma were diagnosed in cats. Of the palpably enlarged mandibular lymph nodes, 17.0% had metastatic disease histologically. Radiographically evident thoracic metastatic disease was present in 7.4% of cases. Preoperative cytologic evaluation of the mandibular lymph node based on fine needle aspiration concurred with the histologic results in 90.5% of lymph nodes examined. Postoperative cytologic evaluation of fine needle aspirates of regional lymph nodes concurred with the histologic results in 80.6% of lymph nodes examined. Only 54.5% of cases with metastatic disease to regional lymph nodes had metastasis that included the mandibular lymph node. Serial lymph node sectioning provided additional information or metastasis detection. Cytologic evaluation of the mandibular lymph node correlates positively with histology, however results may fail to indicate the presence of regional metastasis. Assessment of all regional lymph nodes in dogs and cats with oral or maxillofacial neoplasms will detect more metastatic disease than assessing the mandibular lymph node only.

  3. Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Palmer, Dennis J., E-mail: lyonscreek@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu

    2011-10-15

    Purpose: The purpose of the present study was to integrate safety-engineered devices into outpatient fine-needle aspiration (FNA) biopsy of the thyroid in an interventional radiology practice. Materials and Methods: The practice center is a tertiary referral center for image-directed FNA thyroid biopsies in difficult patients referred by the primary care physician, endocrinologist, or otolaryngologist. As a departmental quality of care and safety improvement program, we instituted integration of safety devices into our thyroid biopsy procedures and determined the effect on outcome (procedural pain, diagnostic biopsies, inadequate samples, complications, needlesticks to operator, and physician satisfaction) before institution of safety devices (54more » patients) and after institution of safety device implementation (56 patients). Safety devices included a patient safety technology-the mechanical aspirating syringe (reciprocating procedure device), and a health care worker safety technology (antineedlestick safety needle). Results: FNA of thyroid could be readily performed with the safety devices. Safety-engineered devices resulted in a 49% reduction in procedural pain scores (P < 0.0001), a 56% reduction in significant pain (P < 0.002), a 21% increase in operator satisfaction (P < 0.0001), and a 5% increase in diagnostic specimens (P = 0.5). No needlesticks to health care workers or patient injuries occurred during the study. Conclusions: Safety-engineered devices to improve both patient and health care worker safety can be successfully integrated into diagnostic FNA of the thyroid while maintaining outcomes and improving safety.« less

  4. Fine needle aspiration of the thyroid

    MedlinePlus

    ... is a butterfly-shaped gland located inside the front of the lower neck. How the Test is Performed This test may be done in the health care provider's office or in a hospital. Numbing medicine (anesthesia) may ...

  5. Displaced epithelium after liposuction for gynecomastia.

    PubMed

    McLaughlin, Cristina S; Petrey, Chris; Grant, Shawn; Ransdell, Jill S; Reynolds, Carol

    2011-08-01

    The authors describe the case of a 36-year-old man with gynecomastia who was previously treated with liposuction of the breast for cosmetic purposes. Histologic examination of a subsequent excisional biopsy revealed nests of displaced epithelial cells in adipose tissue. Epithelial cell displacement is a well-known risk of core needle biopsies and fine-needle aspirations of breast lesions. However, to the authors' knowledge, epithelial displacement in gynecomastia after liposuction, mimicking invasive ductal carcinoma, has not previously been reported.

  6. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    PubMed

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  7. When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?

    PubMed Central

    Schmidt, Robert L.; Walker, Brandon S.; Cohen, Michael B.

    2015-01-01

    Background Rapid on-site evaluation (ROSE) can improve adequacy rates of fine-needle aspiration biopsy (FNAB) but increases operational costs. The performance of ROSE relative to fixed sampling depends on many factors. It is not clear when ROSE is less costly than sampling with a fixed number of needle passes. The objective of this study was to determine the conditions under which ROSE is less costly than fixed sampling. Methods Cost comparison of sampling with and without ROSE using mathematical modeling. Models were based on a societal perspective and used a mechanistic, micro-costing approach. Sampling policies (ROSE, fixed) were compared using the difference in total expected costs per case. Scenarios were based on procedure complexity (palpation-guided or image-guided), adequacy rates (low, high) and sampling protocols (stopping criteria for ROSE and fixed sampling). One-way, probabilistic, and scenario-based sensitivity analysis was performed to determine which variables had the greatest influence on the cost difference. Results ROSE is favored relative to fixed sampling under the following conditions: (1) the cytologist is accurate, (2) the total variable cost ($/hr) is low, (3) fixed costs ($/procedure) are high, (4) the setup time is long, (5) the time between needle passes for ROSE is low, (6) when the per-pass adequacy rate is low, and (7) ROSE stops after observing one adequate sample. The model is most sensitive to variation in the fixed cost, the per-pass adequacy rate, and the time per needle pass with ROSE. Conclusions Mathematical modeling can be used to predict the difference in cost between sampling with and without ROSE. PMID:26317785

  8. [Value of the cytologic diagnosis of adenopathies by aspiration biopsy. Cytohistologic comparison of 1756 cases].

    PubMed

    Zajdela, A; Ennuyer, A; Bataini, P; Poncet, P

    1976-01-01

    The value of the cytologic diagnosis by aspiration needle biopsy is analysed in a series of 1756 adenopathies, verified by histological examination (1311 malignant nodes and 445 inflammatory or normal lymph nodes). The result is that a large number of lymph node tumours, either primary or secondary, are identified by the cytologic examination (from 77% to 91% of the cases according to the explored zone). Furthermore the virtually non existent percentage of false positive results (3% of the cases) proves the great accuracy of this method in the diagnosis of malignancy. In contrast, the diagnosis of benign nature must never be stated without biopsy (2% to 4% of the cases are erroneous by negative according to the explored zone). Indeed, even if benign cells are obtained, nothing allows to eliminate a malignant tumour or a limited inflammatory zone, not reached by the needle.

  9. Diagnostic accuracy of fine-needle aspiration cytology in Warthin tumors.

    PubMed

    Veder, Laura L; Kerrebijn, Jeroen D F; Smedts, Frank M; den Bakker, Michael A

    2010-12-01

    Our aim was to evaluate the diagnostic accuracy of fine-needle aspiration cytology (FNAC) for Warthin tumors of the parotid gland. All cytologic diagnoses of Warthin tumor between 1990 and 2007 were correlated with available histology. In addition, our results were compared to current literature. In 310 cases, Warthin tumor was diagnosed by FNAC. In 133 cases, (43%) both cytology and histology were available. In 127 of these 133 cases (95.5%), the diagnosis Warthin tumor was confirmed by histology. In 4 cases (3%), a benign lesion was diagnosed and 2 (1.5%) revealed a malignant lesion. On review, those cytologic diagnoses were not certain. In the literature, 11 missed malignancies (5.4%) in 202 cases were reported. The diagnostic accuracy of FNAC for the diagnosis of Warthin tumor is high and the percentage of missed malignant tumors is very low. Our results imply that a cytologic diagnosis of Warthin tumor may justify conservative treatment.

  10. Methods specification for diagnostic test accuracy studies in fine-needle aspiration cytology: a survey of reporting practice.

    PubMed

    Schmidt, Robert L; Factor, Rachel E; Affolter, Kajsa E; Cook, Joshua B; Hall, Brian J; Narra, Krishna K; Witt, Benjamin L; Wilson, Andrew R; Layfield, Lester J

    2012-01-01

    Diagnostic test accuracy (DTA) studies on fine-needle aspiration cytology (FNAC) often show considerable variability in diagnostic accuracy between study centers. Many factors affect the accuracy of FNAC. A complete description of the testing parameters would help make valid comparisons between studies and determine causes of performance variation. We investigated the manner in which test conditions are specified in FNAC DTA studies to determine which parameters are most commonly specified and the frequency with which they are specified and to see whether there is significant variability in reporting practice. We identified 17 frequently reported test parameters and found significant variation in the reporting of these test specifications across studies. On average, studies reported 5 of the 17 items that would be required to specify the test conditions completely. A more complete and standardized reporting of methods, perhaps by means of a checklist, would improve the interpretation of FNAC DTA studies.

  11. Regional lymph node staging in breast cancer: the increasing role of imaging and ultrasound-guided axillary lymph node fine needle aspiration.

    PubMed

    Mainiero, Martha B

    2010-09-01

    The status of axillary lymph nodes is a key prognostic indicator in patients with breast cancer and helps guide patient management. Sentinel lymph node biopsy is increasingly being used as a less morbid alternative to axillary lymph node dissection. However, when sentinel lymph node biopsy is positive, axillary dissection is typically performed for complete staging and local control. Axillary ultrasound and ultrasound-guided fine needle aspiration (USFNA) are useful for detecting axillary nodal metastasis preoperatively and can spare patients sentinel node biopsy, because those with positive cytology on USFNA can proceed directly to axillary dissection or neoadjuvant chemotherapy. Internal mammary nodes are not routinely evaluated, but when the appearance of these nodes is abnormal on imaging, further treatment or metastatic evaluation may be necessary. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Fine-needle aspiration cytology of malignant hemangiopericytoma of the salivary gland: A case report.

    PubMed

    Shimizu, K; Ogura, S; Kobayashi, T K; Kushima, R; Toyokuni, S; Iwasa, Y; Sakurai, M

    1999-12-01

    A 79-yr-old woman presented with a 5-yr history of swelling of the left cheek. The fine-needle aspiration (FNA) smear showed a spindle-cell neoplasm with capillaries and benign endothelial cells. The spindle cells possessed pleomorphic, hyperchromatic elongated nuclei and a moderate amount of ill-defined cytoplasm. They also showed papillary arcades surrounded and encased by relatively small ovoid to short spindle cells. Subsequent surgical excision confirmed the presence of malignant hemangiopericytoma (HP). Immunohistochemical studies on the histologic section using vimentin were strongly positive, consistent with HP. To the best of our knowledge, this is the second published report of FNA cellular features of malignant HP of the salivary gland. Besides delineating the FNA cellular features of HP of the salivary gland, the present case illustrates the value of using immunohistochemical approaches. Diagn. Cytopathol. 1999;21:398-401. Copyright 1999 Wiley-Liss, Inc.

  13. Incisional endometriosis: diagnosed by fine needle aspiration cytology.

    PubMed

    Veda, P; Srinivasaiah, M

    2010-07-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03-1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE.

  14. Hidradenocarcinoma presenting as soft tissue mass: Case report with cytomorphologic description, histologic correlation, and differential diagnosis.

    PubMed

    Jinnah, Alexander H; Emory, Cynthia L; Mai, Nicholas H; Bergman, Simon; Salih, Ziyan T

    2016-05-01

    Hidradenocarcinoma (HAC) is a rare adenexal tumor with a propensity for the head and neck region and extremities. We report a case of hidradenocarcinnoma in a 56-year-old woman with a mass on her right palm sampled by fine-needle aspiration and later confirmed on histological examination. Fine-needle aspiration cytology revealed a dual population of cells including polyhedral eosinophilic cells and glycogen containing cells with pale/clear cytoplasm. The nuclei were pleomorphic with prominent nucleoli. Occassional papillary structures were identified on the cell block material. A series of immunohistochemical stains were performed and an adnexal neoplasm was suggested. The mass was resected. On histologic sections, infiltration into the adjacent soft tissue was identified. After an additional series of immunohistochemical stains, the diagnosis was confirmed as a HAC. Herein, we present our findings and discuss the differential diagnoses. © 2016 Wiley Periodicals, Inc.

  15. Fine-needle aspiration in the diagnosis of equine skin disease and the epidemiology of equine skin cytology submissions in a western Canadian diagnostic laboratory.

    PubMed

    Zachar, Erin K; Burgess, Hilary J; Wobeser, Bruce K

    2016-06-01

    Fine-needle aspiration (FNA) is commonly used to diagnose skin disease in companion animals, but its use in horses appears to be infrequent. Equine veterinarians in western Canada were surveyed to determine their opinions about FNA and 15 years of diagnostic submissions were used to compare the perceived to actual value of FNA in the diagnosis of skin disease in horses. Practitioners viewed FNA as quick, easy, economical, and minimally invasive. However, most veterinarians rarely chose to use FNA due to a perception that sample quality and diagnostic yield were poor and there was a narrow range of diseases the technique could diagnose. Analysis of the FNA cytology samples from a veterinary diagnostic laboratory showed a wide variety of equine skin disease conditions, but the frequency of non-diagnostic results was significantly higher in equine submissions compared to those from dogs and cats.

  16. Fine-needle aspiration cytology of intraductal papillary-mucinous tumors: a retrospective analysis.

    PubMed

    Layfield, Lester J; Cramer, Harvey

    2005-01-01

    Intraductal papillary-mucinous tumor (IPMT) of the pancreas has become the accepted terminology for a group of mucin-producing epithelial proliferations lying within ectatic segments of the main pancreatic duct or its large branches. These neoplasms generally are associated with an indolent course, characteristic endoscopic ultrasonographic (EUS) findings, and a variable histo- and cytomorphology ranging from hyperplasia to carcinoma. Cytological specimens obtained by endoscopic ultrasound-guided or percutaneous fine-needle aspiration (FNA) are characterized by a background containing abundant mucin in which are entrapped single or loosely cohesive clusters of neoplastic cells characteristically showing a goblet-cell morphology. The degree of nuclear atypia, cell crowding, and cell shape varies between smears within a single case and between cases. Cytomorphological examination, when coupled with EUS features, is accurate for the diagnosis of these lesions but often it underdiagnoses the grade of the neoplasm. (c) 2005 Wiley-Liss, Inc.

  17. The role of fine needle aspiration cytology in medical-surgical missions.

    PubMed

    Reyes, Cesar V; Reyes, Elisa A

    2009-01-01

    To relate a 6-year, short-term experience of utilizing fine needle aspiration cytology (FNAC) during medical-surgical missions in the impoverished areas of the Philippines. FNAC is a simple, accurate, fast and economical procedure and requires the simplest devices to implement. During medical-surgical missions to the poorest areas in the Third World countries, where there is almost complete lack of tissue processing and frozen section evaluation, and scarcity of laboratory testing, FNAC becomes a practical technique to use. FNAC in these situations plays an important role as an alternative diagnostic modality to surgery. Our week-long mission experience for 6 different years of successful application of FNAC is described. While the mission volunteers have gained extremely rewarding experience in these limited mission works, FNAC has proven to be a very useful adjunct in the delivery of short-term health care during medical-surgical treatment even in a less-than-ideal setting.

  18. Cytologic appearance of retinal cells included in a fine-needle aspirate of a meningioma around the optic nerve of a dog.

    PubMed

    Tvedten, Harold; Hillström, Anna

    2013-06-01

    A 6-year-old Wirehair Dachshund had a meningioma around the optic nerve that caused exophthalmos. A benign mesenchymal tumor was suspected based on the cytologic pattern of a fine-needle aspirate, and a meningioma was diagnosed by histopathologic examination. In addition to the meningioma cells, the cytologic smears included groups of cells from apparently 4 layers of normal retina. In particular, uniform rod-shaped structures in the cytologic sample could suggest rod-shaped bacteria, but these structures were identified as cylindrical outer segments of photoreceptor rod cells. Other retinal structures recognized included pigmented epithelial layer cells with their uniquely formed pigment granules, the characteristic bi-lobed, cleaved nuclei from the outer nuclear layer, and nerve tissue likely from the outer plexiform layer of the retina. © 2013 American Society for Veterinary Clinical Pathology.

  19. Fine-needle aspiration of low-grade adenosquamous carcinomas of the breast: a report of three new cases.

    PubMed

    Bataillon, Guillaume; Collet, Jean-François; Voillemot, Nicole; Menet, Emmanuelle; Vincent-Salomon, Anne; Klijanienko, Jerzy

    2014-01-01

    To describe cytology patterns in low-grade adenosquamous carcinomas (LGASCs) of the breast. Low-grade adenosquamous carcinomas of the breast are a recently described rare variant of primary metaplastic carcinomas characterized by clinical indolence, slow evolution and excellent survival. To date, only 7 cases of LGASC were studied cytologically, and it was demonstrated that LGASC identification was difficult because its cellular components exhibited unspecific and nonsuspicious features. They consisted of irregularly clustered cells without prominent cytonuclear atypia, mitosis or necrosis. The presence of metaplastic cells or keratin debris was helpful in accurate tumor typing. We report here 3 additional cases of LGASC that were initially studied by fine-needle aspiration. We have also encountered diagnostic difficulties and misdiagnosed tumors, since 2 cases were underdiagnosed as 'suspicious' and only 1 was accurately diagnosed as malignancy. The review of our cases and the literature confirms that, despite its putative metaplastic origin, LGASC is an entity which is difficult to diagnose using classical cytological methods. Moreover, core-needle biopsy as well as frozen sections may also misdiagnose LGASC as a benign breast lesion. © 2014 S. Karger AG, Basel.

  20. Fine-needle aspiration cytology of malignant hemangiopericytomas with ultrastructural and flow cytometric analyses.

    PubMed

    Geisinger, K R; Silverman, J F; Cappellari, J O; Dabbs, D J

    1990-07-01

    A hemangiopericytoma (HPC) is an uncommon soft-tissue neoplasm that may arise in many body sites. The cytologic features of fine-needle aspirates (FNAs) of HPCs have only rarely been described in the literature. We examined FNAs of malignant HPCs from the head and neck region (three) and the retroperitoneum (one) in four adults (aged 38 to 83 years). All four FNAs yielded cellular specimens that consisted of uninuclear tumor cells with high nuclear-cytoplasmic ratios. The cytomorphological spectrum included nuclei that were oval to elongate and had very finely granular, evenly distributed chromatin with one or two small but distinct nucleoli. Hemangiopericytomas yield aspirates that may be considered malignant and may suggest sarcoma. Histologically, all four neoplasms manifested high mitotic activity. The ultrastructural features of all four tumors were supportive of the diagnosis of HPC. Although a specific primary diagnosis of HPC on FNA of a soft-tissue mass is unlikely, cytologic analysis may allow diagnosis of recurrent or metastatic HPC. We were able to perform flow cytometric determinations of tumor DNA content on three of the resected neoplasms. In two, an aneuploid pattern was found, including the neoplasm with the most marked pleomorphism in the FNA. The third was diploid.

  1. Fine-needle aspiration biopsy of the salivary gland: problem cases.

    PubMed

    MacLeod, C B; Frable, W J

    1993-01-01

    Among 582 fine-needle aspiration (FNA) biopsies of major and minor salivary glands performed between 1974 and 1990, lack of cytological histologic correlation was noted in 21 cases. Of these, the cause in 10 FNAs was inadequate cytological sampling of the lesion. [One case of malignant hemangiopericytoma was tentatively diagnosed as a monomorphic adenoma on FNA, a polymorphic T-cell lymphoma was diagnosed as granulomatous inflammation on aspiration biopsy, a benign lymphoepithelial lesion was diagnosed as a reactive lymph node, a branchial cleft cyst was called benign mixed tumor (BMT), one case of chronic sialoadenitis was called BMT by FNA, two cases of benign lymphoepithelial lesion (BLEL) were diagnosed as cystic Warthin's tumor, two low-grade mucoepidermoid carcinomas were called BMT, and a BMT was cytologically diagnosed as a Warthin's tumor with squamous metaplasia versus low-grade mucoepidermoid carcinoma. One case of low-grade mucoepidermoid carcinoma was diagnosed only as a "cyst."] Review of these cases identifies constant features that permit differentiation between Warthin's tumor and BLEL, and among BMT, mucoepidermoid carcinoma, and chronic sialoadenitis. Despite a few problem cases, FNA of the salivary gland is accurate in the preoperative diagnosis and classification of salivary gland neoplasms.

  2. Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Huber, K; Heuhold, N

    1987-01-01

    Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.

  3. Cytological Findings of Malignant and Benign Head and Neck Masses in Somalia.

    PubMed

    Baş, Yılmaz

    2018-04-11

    There are no up-to-date records on head and neck masses (HNMs) in Somalia. This cytological study is the first to demonstrate the benefits and findings of fine-needle aspiration cytology in evaluating HNMs in the adult population of Somalia. A total of 116 aspiration samples were taken from different levels of the neck region, except for the thyroid. Cases were classified as salivary gland, lymph node, or soft tissue/cystic lesions. They were classified according to age, gender, and cytological diagnosis. Patients included 54 (46.6%) males and 62 (53.4%) females, with a mean age of 40.6 years. Seventy-two patients (62.1%) had benign lesions, while 44 (37.9%) had malignant lesions. Necrotizing granulomatous lymphadenitis (n = 51, 70.8% of the benign findings) and lymph node metastasis of squamous cell carcinoma (n = 13, 29.5% of the malignant findings) were the most frequent findings. Fine-needle aspiration is a useful procedure in the diagnosis of neck masses. It is a cheap and easy guiding method for diagnosing granulomatous lymphadenitis and advanced-stage metastatic cancers, which are common in this country. © 2018 S. Karger AG, Basel.

  4. Impact of fine needle aspiration (FNA) and of the number of punctures on the feline testis: clinical, gross anatomy and histological assessment.

    PubMed

    Gouletsou, Pagona G; Galatos, Apostolos D; Sideri, Aikaterini I; Kostoulas, Polychronis

    2012-07-01

    The safety of testicular fine needle aspiration (FNA) has been proven in dogs but has not been fully established in men, while studies in rats have given contradictory results. Furthermore, the extent of damage inflicted by multiple punctures is unknown. The aim of this study was to determine the impact of FNA and of the number of punctures on the feline testis with clinical, gross anatomy and histological examinations. Twenty-seven sexually mature healthy laboratory Domestic Shorthair cats were randomly assigned to two groups: 5 cats in which no FNA was performed (control group), and 22 cats which had their left and right testis punctured with a 26 ga needle towards 3 and 8 directions, respectively (experimental group). Two cats at a time were orchiectomized 5 or 30 min, 1, 2, 4, 7 or 14 days or 1, 2, 3 or 4 mo post-aspiration. The cats of the control group were also orchiectomized. During the first week post-aspiration clinical examination revealed vaginal cavity hematoma (8/44 testes), while the histological findings were focal hemorrhagic areas (20/24 testes), erythrocytes inside the seminiferous tubules' lumen (9/24 testes), and germinal cell degeneration in <1.94% of the seminiferous tubules (15/24 testes). After the first week the histological findings were germinal cell degeneration in <2.14% of the seminiferous tubules (19/20 testes) and enlargement of the lumen of <5.16% of the seminiferous tubules (7/20 testes). The germinal epithelium and interstitium had an overall normal appearance. No significant differences were observed between the left and right testis. The results of the study indicate that testicular FNA should be considered a safe procedure in the cat when up to 8 punctures are performed. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Targeted Next Generation Sequencing with ThyroSeq v2.1 for Indeterminate Thyroid Nodules in Clinical Practice.

    PubMed

    Witt, Robert L

    2016-12-01

    To determine if patients elect molecular testing over diagnostic surgery or repeat fine needle aspiration for indeterminate thyroid nodules. Can ThyroSeq v2.1 molecular testing reduce diagnostic thyroid surgery and rule out cancer? Retrospective review Setting: Single institution, single-practice surgeon. Fifteen month retrospective review of indeterminate thyroid nodules that went on to ThyroSeq v2.1 testing. 286 patients met American Thyroid Association guideline criteria for surgeon- performed, ultrasound-guided fine needle aspiration for a thyroid nodule with on-site cytopathology. The indeterminate (Bethesda III or IV) fine needle aspiration cytology rate was 9.1 percent. Prevalence of malignancy in indeterminate nodules was 19 percent. 26/26 (100 percent) patients with indeterminate thyroid nodules elected molecular testing. 16 patients had no mutation, 9 had one or more mutations, and I had no result. 16 of 25 (64 percent) patients with no mutation elected not to undergo diagnostic surgery for indeterminate thyroid nodules. Patients demonstrated a strong preference for molecular testing instead of diagnostic thyroid surgery for indeterminate thyroid nodules. All patients in this series, 25/25 (100 percent) with indeterminate thyroid nodules elected molecular testing instead of repeat biopsy or diagnostic thyroid surgery. 16 of 25 (64 percent) patients tested had no mutation. All 16/16 (100 percent) patients with no mutation on ThyroSeq "rule out" testing elected active surveillance rather than surgery or biopsy, reducing diagnostic surgery. The risk of malignancy among mutation negative patients was not definitively established. There are a number of factors currently that may mute the power of "rule in" testing.

  6. Testicular cytological profiles of apparently healthy male dromedary camels during rutting and non-rutting periods.

    PubMed

    Melaku, Simenew Keskes; Regassa, Fekadu; Tessema, Tesfaye Sisay; Kassa, Tesfu; Vencato, Juri; Owiny, David Okello; Stelletta, Calogero

    2015-12-01

    The aim of this study was to evaluate testicular cytological profiles of apparently healthy dromedary bulls during rutting and non-rutting periods. Pairs of testes from 26 (18 non-rutting and 8 rutting seasons) dromedary bulls 6-12 years old that were slaughtered at Akaki, Addis Ababa abattoir were sampled. A 21 gauge needle attached to 20mL syringe was used to collect Testicular Fine Needle Aspiration (TFNA) samples and five aspiration smears were prepared from each testis. A total of 312 slides (260 Testicular fine Needle Aspiration and 52 imprints) were examined. The mod ified May-Grunwald Giemsa (mMGG) technique and a light microscope were used to assess cellularity, morphology and quantification of the testicular. Sertoli and spermatogenic cells were identified and counted. The spermatic index (SI), Sertoli cell index (SEI) and the relationship between SI and SEI indexes (SSEI) were used to assess the ratio between mature spermatozoa and nursing cells. There were differences (P<0.05) between the rutting and non-rutting seasons among the spermatogenic and Sertoli cells. There were no differences between groups for primary spermatocyte numbers, early spermatid numbers and SSEI. There was no differences (P>0.05) between TFNA and imprint smear slides of the testicular cells except for Sertoli cell count and SEI. Filarial worm larvae were present on the TFNA smear slides of four animals. Imprint and TFNA smear slides had comparable cytological profiles in dromedary bulls and significant differences were observed between rutting and non-rutting periods. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Silk suture reaction in thyroid surgery

    PubMed Central

    Soylu, Selen; Teksoz, Serkan; Ozcan, Murat; Bukey, Yusuf

    2017-01-01

    Silk suture reaction (i.e., a benign granulomatous inflammatory foreign body reaction) is a rare complication of thyroid surgery. Here, two cases of post-thyroidectomy suture reaction are presented. Both of the patients were female, one is 48 and the other is 34 years old. The patients were presented with neck swelling and leakage of serous fluid from the Kocher’s incision. Both patients had normal free T4, free T3, and TSH values. The 48-year-old female patient had a right subtotal and left near-total thyroidectomy 6 years ago and the other had bilateral total thyroidectomy 6 years ago. In the physical examination a mobile, painless, red, swelling was palpated in front of neck. In the ultrasound of both patients, a heterogeneous nodule with hypoechoic rim was seen, however, in scintigraphy no radiopharmaceutical involvement was observed in thyroid region. Due to suspicion of thyroid malignancy, a fine needle aspiration biopsy was performed and foreign body reaction was revealed cytologically. A suture reaction can vary from an erythematous swelling to chronic granulomatous reaction. The time interval between the operation and formation of suture reaction was 6 years in both of the cases thus these patients were considered as chronic patients. Foreign body reaction diagnosis was confirmed with fine needle aspiration biopsy. It is important to diagnose these chronic inflammation cases since these cases can mimic recurrence in thyroid malignancies. A post-thyroidectomy suture reaction is diagnosed cytologically with fine needle aspiration biopsy and by surgical removal of suture, this chronic inflammatory reaction can be cured. PMID:29142853

  8. Thyroid Nodules

    MedlinePlus

    ... the thyroid and see if the nodule is solid or filled with fluid (cystic). Although this test cannot tell if the nodule is cancerous, it is very useful to guide the needle to remove (aspirate) cells from nodules. This procedure is called “ultrasound-guided ...

  9. [Study on pulmonary lesions in which nontuberculous mycobacteria were detected by percutaneous aspiration--a proposal to add "culture positivity of percutaneous aspiration material" to the bacteriological diagnostic criteria of pulmonary nontuberculous mycobacterial diseases].

    PubMed

    Nakahara, Yasuharu; Mochizuki, Yoshiro; Kawamura, Tetsuji; Sasaki, Shin; Morimoto, Akie; Mizumori, Yasuyuki; Tsukamoto, Hiroaki; Watanabe, Etsuko; Yokoyama, Toshihide

    2013-03-01

    Culture positivity of percutaneous aspiration material" is not included in the current bacteriological criteria for diagnosis of pulmonary nontuberculous mycobacterial (NTM) diseases, which were published by the Infectious Diseases Society of America (IDSA)/American Thoracic Society (ATS) in 2007 or those released by the Japanese Society for Tuberculosis in 2008. However, percutaneous aspiration is a reliable technique for the detection of causative microorganisms isolated from the focus of infection. We discuss the benefits of including positive culture of percutaneous aspiration material in the bacteriological diagnostic criteria of pulmonary NTM diseases. We reviewed the radiological images and clinical courses of pulmonary diseases in which NTM cultures were obtained from percutaneously aspirated materials at our hospital from 1991 to 2011. Aspiration was carried out under local anesthesia, usually with fluoroscopic guidance. After percutaneous insertion of a 22-gauge needle attached to a 20-mL syringe containing about 3 mL of saline, the lesion specimen was withdrawn together with the saline. After the needle was pulled out, the aspirated material and saline were transferred to test tubes for cytological and microbiological examinations. In patients with thin-walled cavitary lesions, saline was injected into the cavity and then aspirated. Percutaneous aspiration was performed in 2,742 patients and NTM disease was detected in 51 patients. Of these 51 patients, 12 had solitary nodular lesions, and in many of these patients, no NTM bacilli could be detected in the sputa or bronchial washing specimens. Mycobacterium avium was identified in 10 of the 12 cases. Four of these 10 patients were followed up after their diagnosis without any treatment: 3 showed spontaneous reduction in lesion size, while 1 patient's condition remained unchanged. Four of the remaining 6 cases were treated with anti-NTM medications, and lesion size reduced in 2 cases, while no change or deterioration was seen in the other 2. Aspiration from solitary small cavitary lesions showed a relatively high number of NTM colonies. Pneumothorax was the only complication of the aspiration procedure. If the diagnostic criteria for pulmonary NTM diseases include positive culture in percutaneous aspiration material, the diagnosis of solitary nodular NTM lesions would become easier; at present, these lesions are often diagnosed only upon surgical resection. Further, clinical studies on the possibility of spontaneous shrinkage of the solitary lesion and the value of its medical treatment would be promoted. Aspiration can easily differentiate NTM disease from pulmonary abscess or fungal infection in patients with a solitary lesion or small cavity.

  10. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  11. Diagnosis of Metastasis to the Thyroid Gland: Comparison of Core-Needle Biopsy and Fine-Needle Aspiration.

    PubMed

    Choi, Sang Hyun; Baek, Jung Hwan; Ha, Eun Ju; Choi, Young Jun; Song, Dong Eun; Kim, Jae Kyun; Chung, Ki-Wook; Kim, Tae Yong; Lee, Jeong Hyun

    2016-04-01

    Early detection and diagnosis of metastasis to the thyroid gland is important. This study aims to evaluate the clinical value of core-needle biopsy (CNB) by comparing the results of CNB and fine-needle aspiration (FNA) in patients with clinically suspected metastasis to the thyroid gland. Case series with chart review. Tertiary referral practice. Fifty-two thyroid nodules from 52 patients with clinically suspected metastasis to the thyroid gland (mean age, 62.8 years). Of these 52 patients, FNA was initially used in 41 patients and CNB in 20 patients (11 patients as the initial approach and 9 patients after inconclusive FNA results). Ultrasound features of metastasis to the thyroid gland were evaluated. The diagnostic performance, repeated diagnostic examination rate, and diagnostic surgery rate were evaluated for FNA and CNB. Among these 52 patients, 46 were diagnosed with thyroid metastases and 6 were diagnosed with primary thyroid cancer. Common ultrasound features were an ovoid to round shape (58.7%), ill-defined margin (56.5%), hypoechogenicity (65.2%), and no calcifications (87.0%). Core-needle biopsy achieved a significantly higher sensitivity than FNA (100.0% vs 58.6%, P = .008) without any false-negative results. Both the repeated diagnostic examination rate and the diagnostic surgery rate were significantly lower in CNB than in FNA (5.0% vs 46.3%, P = .001, and 5.0% vs 34.1%, P = .013, respectively). In cases of known rare primary malignancy, nontypical ultrasound features of primary thyroid malignancy, and need for an additional immunohistochemical analysis, CNB may be primarily considered. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  12. Should fine needle aspiration biopsy be the first pathological investigation in the diagnosis of a bone lesion? An algorithmic approach with review of literature

    PubMed Central

    Mehrotra, Ravi; Singh, Mamta; Singh, Premala A; Mannan, Rahul; Ojha, Vinod K; Singh, Pradumyn

    2007-01-01

    Background Fine needle aspiration biopsy (FNAB) is gaining increasing popularity in the diagnosis of musculoskeletal lesions; and in many patients, a definitive diagnosis can be rendered from aspiration smears alone. Its applicability in bone pathology, however, has been controversial due to a high percentage of inadequate smears, difficulty in evaluation of tissue architecture and nonspecific results in the diagnosis of primary bone lesions. In this study, the value of aspiration as the first pathological investigation in the diagnosis of a bone lesion was evaluated. Methods 91 cases of clinically suspected cases of bone lesions were aspirated over a period of two years. Direct or cytospin smears were fixed in 95% alcohol and stained by Hematoxylin and Eosin or air-dried and later fixed in methanol for May Grŭnwald Giemsa staining. Results Of the 91 patients who were subjected to FNAB, 81 were considered satisfactory and 10.9 % (10) were inadequate\\inconclusive for diagnosis. Cyto-histological concordance was obtained in 78.5 % (51/65) patients. Positive and negative predictive values were 87.5% and 97.2 % respectively. Sensitivity as a preliminary diagnostic technique was 93.3%, whereas specificity was 94.5 %. Overall, diagnostic accuracy was 94.2 %. Metastatic lesions were detected with 100% accuracy. Two cases were reported as false positive and one case as false negative. Conclusion Cytology provides valuable information to the clinician to make an informed decision regarding appropriate therapy. We conclude that time-consuming and costly investigations may be reduced by choosing FNAB as the initial pathological diagnostic method for skeletal lesions of unknown origin. The choice of radiological examinations, laboratory tests and surgical biopsies can be determined after the FNAB diagnosis. PMID:17439659

  13. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    PubMed

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting safety-engineered devices for an orthopaedic clinic, conventional syringes larger than 20 mL and conventional needles longer than 1.5 in (3.8 cm) are necessary.

  14. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer.

    PubMed

    Mikosiński, Sławomir; Pomorski, Lech; Oszukowska, Lidia; Makarewicz, Jacek; Adamczewski, Zbigniew; Sporny, Stanisław; Lewiński, Andrzej

    2006-01-01

    Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and (131)I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15-711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94-100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes in patients with differentiated thyroid cancer.

  15. Bronchoscopy with endobronchial ultrasound guided transbronchial needle aspiration vs. transthoracic needle aspiration in lung cancer diagnosis and staging.

    PubMed

    Munoz, Mark L; Lechtzin, Noah; Li, Qing Kay; Wang, KoPen; Yarmus, Lonny B; Lee, Hans J; Feller-Kopman, David J

    2017-07-01

    In evaluating patients with suspected lung cancer, it is important to not only obtain a tissue diagnosis, but also to obtain enough tissue for both histologic and molecular analysis in order to appropriately stage the patient with a safe and efficient strategy. The diagnostic approach may often be dependent on local resources and practice patterns rather than current guidelines. We Describe lung cancer staging at two large academic medical centers to identify the impact different procedural approaches have on patient outcomes. We conducted a retrospective cohort study of all patients undergoing a lung cancer diagnostic evaluation at two multidisciplinary centers during a 1-year period. Identifying complication rates and the need for multiple biopsies as our primary outcomes, we developed a multivariate regression model to determine features associated with complications and need for multiple biopsies. Of 830 patients, 285 patients were diagnosed with lung cancers during the study period. Those staged at the institution without an endobronchial ultrasound (EBUS) program were more likely to require multiple biopsies (OR 3.62, 95% CI: 1.71-7.67, P=0.001) and suffer complications associated with the diagnostic procedure (OR 10.2, 95% CI: 3.08-33.58, P<0.001). Initial staging with transthoracic needle aspiration (TTNA) and conventional bronchoscopy were associated with greater need for subsequent biopsies (OR 8.05 and 14.00, 95% CI: 3.43-18.87 and 5.17-37.86, respectively) and higher complication rates (OR 37.75 and 7.20, 95% CI: 10.33-137.96 and 1.36-37.98, respectively). Lung cancer evaluation at centers with a dedicated EBUS program results in fewer biopsies and complications than at multidisciplinary counterparts without an EBUS program.

  16. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters

    PubMed Central

    Lippi, Giuseppe; Cervellin, Gianfranco; Mattiuzzi, Camilla

    2013-01-01

    Background: A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. Materials and methods: We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. Results: Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40). Conclusions: Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. PMID:23894864

  17. Impact of endoscopic ultrasound-guided fine-needle aspiration in prospective liver transplant recipients with hepatocellular carcinoma and lymphadenopathy.

    PubMed

    Choudhary, Narendra S; Puri, Rajesh; Saigal, Sanjiv; Bhangui, Prashant; Saraf, Neeraj; Shah, Vinit; Nasa, Mukesh; Sarin, Haimanti; Guleria, Mridula; Sud, Randhir; Soin, Arvinder S

    2016-11-01

    Diagnosis of metastatic disease is important in patients with cirrhosis and hepatocellular carcinoma (HCC) to prevent futile liver transplantation. Some of these patients have metastatic lymphadenopathy; however, it is difficult to perform percutaneous fine-needle aspiration due to presence of collateral and anatomic location. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) of lymph nodes offers several advantages like real-time vision, proximity to target, and avoidance of collaterals. The aim of this study was to look for metastatic lymphadenopathy by EUS-guided FNA (EUS-FNA) in prospective liver transplant recipients with HCC. A prospective study was conducted from January 2013 to January 2016 at a tertiary care center. All prospective liver transplant recipients with HCC had PET-CT and bone scan to look for metastatic disease. EUS-FNA was done in patients with abdominal or mediastinal lymphadenopathy and no evidence of extrahepatic disease. Data is shown as median (25-75 interquartile range). EUS-guided FNA was done for 50 patients (42 abdominal and 8 mediastinal lymph nodes), age 57 (53-62) years, Child-Turcotte-Pugh 7 (6-9), and model for end-stage liver disease 10 (7-16). FNA material was adequate in 92% patients, metastasis in 15 (30%), granulomatous lymphadenopathy in 4 (8%), and reactive change in 27 patients (54%). The material was inadequate for diagnosis in 4 (8%) patients. Thus, EUS-guided FNA precluded transplantation in 30% of patients with lymphadenopathy, and 4 (8%) patients received anti-tubercular therapy before liver transplantation. In patients with HCC and lymphadenopathy, EUS-guided FNA detected metastatic disease and precluded liver transplantation in approximately one third of patients.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhan, Okan, E-mail: akhano@tr.net; Islim, Filiz, E-mail: fislim@yahoo.com; Balci, Sinan, E-mail: snnbalci@gmail.com

    PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 monthsmore » (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.« less

  19. An analysis of the effectiveness of two topical anesthetics.

    PubMed Central

    Rosivack, R. G.; Koenigsberg, S. R.; Maxwell, K. C.

    1990-01-01

    This study compared the effectiveness of topical benzocaine 20%, lidocaine 5%, and a placebo in reducing the pain caused by needle insertion when the medicament was placed in the mucobuccal fold above the maxillary canine eminence. Both topical anesthetics and the placebo were randomly tested against each other bilaterally. For uniformity the agents were left in place for three minutes before needle insertion. A 27 gauge short needle mounted on an aspirating syringe was then inserted just past the bevel. Each subject rated the degree of pain on a visual analogue scale 100 mm in length. A pulse oximeter was used to record the heart rate. The results indicate that both topical anesthetics are significantly better than the placebo in reducing pain caused by needle insertion, although no statistically significant differences were found between the two topical anesthetics. Statistically significant differences in heart rate were seen, but these differences were not clinically significant. It is concluded that benzocaine 20% and lidocaine 5% significantly reduce the pain during needle insertion. PMID:2097909

  20. Fine-needle aspiration cytology of postirradiation sarcomas, including angiosarcoma, with immunocytochemical confirmation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silverman, J.F.; Lannin, D.L.; Larkin, E.W.

    1989-01-01

    Postirradiation sarcomas are an unusual but well-recognized late effect of cancer therapy. In this article, a fine-needle aspiration (FNA) series of four cases is presented. There were three female patients and one male patient, with an age range of 28-55 yr (mean, 41). Two of the patients were irradiated for uterine cervical carcinoma while the other two received irradiation for malignant lymphoma. The time interval to the development of the postirradiation sarcoma ranged from 10 to greater than 20 yr. There were a postirradiation synovial sarcoma of the buttock region, malignant fibrous histiocytoma of the bone (femur), and rhabdomyosarcoma andmore » angiosarcoma of the retroperitoneum. A spectrum of cytologic findings was encountered, reflecting the specific types of sarcomas. Immunocytochemical studies performed on the aspirated material from the angiosarcoma demonstrated the utility of immunoperoxidase stains for ULEX europaeus agglutinin-1 (UEA-1) and, to a lesser degree, factor VIII-related antigen antibody, confirming the vascular nature of this malignancy. The FNA findings from all four cases demonstrated cytologic features that allowed recognition of this unusual complication of irradiation treatment. This article confirms the utility of FNA cytology in following patients with previous malignancies and differentiating a postirradiation sarcoma from recurrent carcinoma.« less

  1. Massive Air Embolism During Interventional Laser Therapy of the Liver: Successful Resuscitation Without Chest Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helmberger, Thomas K.; Roth, Ute; Empen, Klaus

    2002-08-15

    We report on a rare, acute, life-threatening complication during percutaneous thermal therapy for hepatic metastases. Massive cardiac air embolism occurred during a maneuver of deep inspiration after the dislodgement of an introducer sheath into a hepatic vein. The subsequent cardiac arrest was treated successfully by immediate transthoracic evacuation of the air by needle aspiration followed by electrical defibrillation. In procedures that may be complicated by gas embolism, cardiopulmonary resuscitation should not be initiated before considering the likelihood of air embolism, and eventually aspiration of the gas.

  2. Subcutaneous aspergillosis with coexisting atypical mycobacterial infection.

    PubMed

    Duraipandian, Jeyakumari; Rengasamy, Gopal; Madasamy, Balamurugan; Kulanthaivelu, Ambedkarraj; Subramanian, Girija

    2010-01-01

    A 60-year-old woman, a known diabetic and asthmatic, was admitted for acute exacerbation of chronic obstructive pulmonary disease. Physical examination revealed two soft nodules in the left infra axillary region. Fine needle aspiration cytology (FNAC) showed fungal granulomatous reaction suggestive of fungal infection. Periodic acid Schiff stain (PAS stain) revealed PAS positive, acutely branching, septate fungal hyphae. Wet mount of the aspirate revealed plenty of pus cells and branching septate hyphae. Ziehl-Neelsen (ZN) stain showed moderate numbers of acid fast bacilli. Culture yielded Aspergillus flavus and Mycobacterium fortuitum.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucourt, Maximilian de, E-mail: mdb@charite.de; Streitparth, Florian, E-mail: florian.streitparth@charite.de; Collettini, Federico

    Purpose: To evaluate the feasibility of minimally invasive magnetic resonance imaging (MRI)-guided free-hand aspiration of symptomatic nerve route compressing lumbosacral cysts in a 1.0-Tesla (T) open MRI system using a tailored interactive sequence. Materials and Methods: Eleven patients with MRI-evident symptomatic cysts in the lumbosacral region and possible nerve route compressing character were referred to a 1.0-T open MRI system. For MRI interventional cyst aspiration, an interactive sequence was used, allowing for near real-time position validation of the needle in any desired three-dimensional plane. Results: Seven of 11 cysts in the lumbosacral region were successfully aspirated (average 10.1 mm [SDmore » {+-} 1.9]). After successful cyst aspiration, each patient reported speedy relief of initial symptoms. Average cyst size was 9.6 mm ({+-}2.6 mm). Four cysts (8.8 {+-} 3.8 mm) could not be aspirated. Conclusion: Open MRI systems with tailored interactive sequences have great potential for cyst aspiration in the lumbosacral region. The authors perceive major advantages of the MR-guided cyst aspiration in its minimally invasive character compared to direct and open surgical options along with consecutive less trauma, less stress, and also less side-effects for the patient.« less

  4. Detecting and Treating Thyroid Nodules and Cancer Before, During, and After Pregnancy

    MedlinePlus

    ... nodules relies mainly on the results of thyroid ultrasound imaging and fine-needle aspiration biopsy . A biopsy is the removal of a small sample of the nodule for further testing. Thyroid ultrasound uses the same safe technique of high- frequency ...

  5. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    PubMed

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  6. Asymptomatic vallecular cyst: case report.

    PubMed

    Yuce, Yucel; Uzun, Sennur; Aypar, Ulku

    2013-01-01

    A 56-year-old man presented himself for an intracranial glioblastoma multiforme excision. After being routinely monitored, he was preoxygenated. We induced anesthesia and paralysis with 200 mg propofol, 50 μg fentanyl and 9 mg vecuronium. Direct laryngoscopy with a Macintosh 3 blade revealed a 2x2 cm cyst, pedunculated, arising from the right side of the vallecula preventing the endotracheal intubation. While the patient remained anesthetized, we urgently consulted an otolaryngologist and aspirated the cyst with a 22-gauge needle and syringe under direct laryngoscopy. We aspirated 10 cc of liquid content. This was followed by an uneventful tracheal intubation with a 9.0 enforced spiral cuffed tube. An alternative to fiberoptic intubation may be careful cyst aspiration to facilitate the intubation.

  7. TERT, HRAS, and EIF1AX Mutations in a Patient with Follicular Adenoma.

    PubMed

    Topf, Michael C; Wang, Zi-Xuan; Tuluc, Madalina; Pribitkin, Edmund A

    2018-06-01

    Molecular markers are increasingly used as diagnostic tools in the management of thyroid nodules. There is a paucity of studies evaluating the prevalence of molecular markers in benign lesions. A 68-year-old woman with hypothyroidism presented with a right thyroid nodule, which was atypia of undetermined significance on cytology. The fine-needle aspirate of the nodule was examined with next-generation sequencing and found to harbor a C228T mutation in the TERT gene, a Q61R mutation in the HRAS gene, and an A113_splice mutation in the EIF1AX gene. Right thyroid lobectomy was performed, with final pathology showing follicular adenoma. All three mutations detected in the original fine-needle aspirate specimen were detected in the final surgical specimen as well. A rare case of TERT, HRAS, and EIF1AX mutations is reported in a patient with follicular adenoma. TERT promoter mutations may be an early genetic event in the molecular pathogenesis of follicular thyroid carcinoma.

  8. Pancreatic fine needle aspiration. A comparison of computed tomographic and endoscopic ultrasonographic guidance.

    PubMed

    Qian, Xiaohua; Hecht, Jonathan L

    2003-01-01

    To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.

  9. Tuberculous Dactylitis: An Uncommon Presentation of Skeletal Tuberculosis.

    PubMed

    Abebe, Workeabeba; Abebe, Betel; Molla, Kebede; Alemayehu, Tinsae

    2016-05-01

    Skeletal involvement accounts 1-5% of all cases of Tuberculosis. The vertebrae are more commonly affected. The bones of the hands are more affected than the bones of the feet. The term "spina ventosa" has been used to describe this disorder because of its radiographic features of cystic expansion of the involved short tubular bones. Tuberculous dactylitis mainly occurs through lympho-hematogenous spread. The lung is the primary focus in 75% of cases. A 4 years old female child developed a painless swelling on her left index finger two months prior to her presentation. Following an unsuccessful treatment as a case of osteomyelitis with antibiotics, imaging showed an expansile lytic lesion with sclerosis, and fine needle aspiration confirmed tuberculous dactylitis. The child was initiated on anti-tubercular treatment with subsequent marked clinical and radiologic improvement. Presence of longstanding finger swelling and pain should alert a clinician to consider active disseminated tuberculosis. Furthermore, proper interpretation of imaging and use of fine needle aspiration has been highlighted.

  10. Gallium-67 uptake by the thyroid associated with progressive systemic sclerosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sjoberg, R.J.; Blue, P.W.; Kidd, G.S.

    1989-01-01

    Although thyroidal uptake of gallium-67 has been described in several thyroid disorders, gallium-67 scanning is not commonly used in the evaluation of thyroid disease. Thyroidal gallium-67 uptake has been reported to occur frequently with subacute thyroiditis, anaplastic thyroid carcinoma, and thyroid lymphoma, and occasionally with Hashimoto's thyroiditis and follicular thyroid carcinoma. A patient is described with progressive systemic sclerosis who, while being scanned for possible active pulmonary involvement, was found incidentally to have abnormal gallium-67 uptake only in the thyroid gland. Fine needle aspiration cytology of the thyroid revealed Hashimoto's thyroiditis. Although Hashimoto's thyroiditis occurs with increased frequency in patientsmore » with progressive systemic sclerosis, thyroidal uptake of gallium-67 associated with progressive systemic sclerosis has not, to our knowledge, been previously described. Since aggressive thyroid malignancies frequently are imaged by gallium-67 scintigraphy, fine needle aspiration cytology of the thyroid often is essential in the evaluation of thyroidal gallium-67 uptake.« less

  11. Fine needle aspiration cytology of radiation-induced changes in nonneoplastic breast lesions. Possible pitfalls in cytodiagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterse, J.L.; Thunnissen, F.B.; van Heerde, P.

    1989-03-01

    The range of radiation-induced changes in fine needle aspiration (FNA) smears of the breast is described. In 41 of more than 800 patients who underwent breast-conserving treatment, a palpable breast lesion developed, and FNA was performed. In six cases, a recurrent carcinoma was present. In the remaining cases, three patterns of nonneoplastic lesions could be discerned: epithelial atypia (14 cases), fat necrosis (10 cases) and poorly cellular smears without epithelial atypia or fat necrosis (13 cases). It is important to be familiar with the patterns of radiation-induced epithelial atypia, since such atypia may lead to a misdiagnosis of recurrent carcinoma.more » These atypical cells may show impressive anisocytosis and anisonucleosis; however, the nuclear/cytoplasmic ratio remains normal and an admixture of bipolar cells is present. Cell dissociation and necrotic cell debris, as often seen in breast cancer smears, were never encountered in FNA smears from radiated nonneoplastic breasts.« less

  12. A resected perivascular epithelioid cell tumor (PEComa) of the pancreas diagnosed using endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Okuwaki, Kosuke; Kida, Mitsuhiro; Masutani, Hironori; Yamauchi, Hiroshi; Katagiri, Hiroyuki; Mikami, Tetuo; Miyazawa, Shiro; Iwai, Tomohisa; Takezawa, Miyoko; Imaizumi, Hiroshi; Koizumi, Wasaburo

    2013-01-01

    Primary perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare. We herein report our experience with a patient who had a primary PEComa of the pancreas that was diagnosed by the preoperative histopathological examination of a biopsy specimen obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 43-year-old woman whose chief complaint was abdominal pain. Imaging studies revealed a pancreatic tumor. Gastrointestinal stromal tumor (GIST), solid pseudopapillary tumor and neuroendocrine tumor were considered in the differential diagnosis. A histopathological examination of a specimen of the tumor obtained using EUS-FNA showed spindle-shaped tumor cells with enlarged nuclei and eosinophilic cytoplasm. The tumor cells proliferated in a sheet-like fashion and stained positive for the melanoma-associated antigen HMB-45. A PEComa was thus diagnosed. If an adequate tumor specimen can be obtained using EUS-FNA, immunostaining may facilitate the diagnosis of extremely rare diseases and therefore assist in deciding the treatment policy.

  13. Thyroid nodules.

    PubMed

    Knox, Mark A

    2013-08-01

    Thyroid nodules are a common finding in the general population. They may present with symptoms of pressure in the neck or may be discovered during physical examination. Although the risk of cancer is small, it is the main reason for workup of these lesions. Measurement of thyroid-stimulating hormone can identify conditions that may cause hyperfunctioning of the thyroid. For all other conditions, ultrasonography and fine-needle aspiration are central to the diagnosis. Lesions larger than 1 cm should be biopsied. Lesions with features suggestive of malignancy and those in patients with risk factors for thyroid cancer should be biopsied, regardless of size. Smaller lesions and those with benign histology can be followed and reevaluated if they grow. The evaluation of thyroid nodules in euthyroid and hypothyroid pregnant women is the same as in other adults. Thyroid nodules are uncommon in children, but the malignancy rate is much higher than in adults. Fine-needle aspiration is less accurate in children, so more aggressive surgical excision may be preferable.

  14. Pituitary carcinoma diagnosed on fine needle aspiration: Report of a case and review of pathogenesis

    PubMed Central

    Yakoushina, Tatiana V.; Lavi, Ehud; Hoda, R. S.

    2010-01-01

    Pituitary carcinoma (PC) is a very rare entity (0.2% of all pituitary tumors), with only about 140 cases reported in English literature. There are no reliable histological, immunohistochemical or ultrastructural features distinguishing pituitary adenoma (PA) from PC. By definition, a diagnosis of PC is made after a patient with PA develops non-contiguous central nervous system (CNS) or systemic metastases. To date, only three cases of PC have been reportedly diagnosed on fine needle aspiration (FNA). Two of the reported cases were diagnosed on FNA of the cervical lymph nodes and one on FNA of the vertebral bone lesion. Herein, we present a case of PC, diagnosed on FNA of the liver lesion. In this case, we describe cytologic features of PC and compare them to histologic features of the tumor in the pituitary. Clinical behavior of tumor, pathogenesis of metastasis and immunochemical and prognostic markers will also be described. PMID:20806088

  15. P-LUM-08: Endoscopic ultrasound-guided fine needle aspiration: A new modality to diagnose peritoneal tuberculosis in the presence of decompensated cirrhosis – a case series

    PubMed Central

    Daswani, Ravi; Singla, Vikas; Arora, Anil; Sharma, Praveen; Bansal, Naresh; Kumar, Ashish

    2017-01-01

    The gold standard for diagnosis of peritoneal tuberculosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the nonspecific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low, and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Thus, there is an urgent need to explore newer diagnostic modalities, especially those that can provide perioneal tissue by less invasive means. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal tuberculosis (TB). We hereby report the use of EUS- FNA of the peritoneum in five patients with decompensated cirrhosis, in whom the diagnosis could not be confirmed by other means; thus, we propose EUS-FNA of the peritoneum as a new, safe, and unexplored technique for diagnosis of peritoneal TB.

  16. Induction of parotitis by fine-needle aspiration in parotid Warthin's tumor.

    PubMed

    Suzuki, Kensuke; Iwai, Hiroshi; Kaneko, Toshihiko; Sakaguchi, Mariko; Hoshino, Shoichi; Inaba, Muneo

    2009-08-01

    To estimate parotitis caused by fine-needle aspiration (FNA) in parotid Warthin tumor. Case series with chart review. Hospital records were reviewed for 104 parotid tumors (103 patients) including 35 Warthin tumors, which underwent FNA within our department. Three patients with four Warthin tumors among them noticed parotid pain, swelling, and abscess formation as a consequence of acute parotitis after FNA. Examinations of the materials obtained from tumor puncture or drainage before the start of antibiotic therapy showed no bacterial association in any patient. Two of the patients with Warthin tumor underwent parotidectomy, and the surgical specimens indicated histopathological changes with necrosis, abscess, granuloma, and the infiltration of inflammatory cells including Langhans-type multinucleated giant cells. It is conceivable that Warthin tumor bears the characteristics of inflammation induced by the FNA procedure without any relation to infection. Therefore, it may be better to avoid routine FNA and give priority to diagnostic imagings over FNA in the diagnosis of tumors strongly suspected as Warthin tumor.

  17. Incisional Endometriosis: Diagnosed by Fine Needle Aspiration Cytology

    PubMed Central

    Veda, P; Srinivasaiah, M

    2010-01-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03–1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE. PMID:21346911

  18. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    PubMed

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  19. Rosai-Dorfman disease of the breast in a male: a case report.

    PubMed

    Bansal, Pankaj; Chakraborti, Shrijeet; Krishnanand, Geeta; Bansal, Rohini

    2010-01-01

    Rosai-Dorfman disease (RDD), or sinus histiocytosis with massive lymphadenopathy, is a benign, self-limiting disease. In the majority of cases, there is massive and painless lymphadenopathy in any lymph node group but most commonly in the cervical lymph nodes, associated with constitutional symptoms. Extranodal involvement has been reported to occur in almost every organ system, with or without concomitant nodal disease. The breast is a rare site of presentation of this disease. A 35-year-old male presented with a hard, nodular swelling in the lower and outer quadrant of the right breast, with a clinical suspicion of malignancy. A diagnosis of sinus histiocytosis with massive lymphadenopathy, or RDD, was offered based on the presence of numerous lymphocytes, plasma cells, a few neutrophils and large histiocytes showing emperipolesis in fine needle aspiration smears. Mammary RDD is extremely rare in males. The cytologic features are fairly characteristic and should be considered in the differential diagnosis whenever atypical histiocytes and emperipolesis are encountered in fine needle aspiration smears.

  20. Application of Sal classification to parotid gland fine-needle aspiration cytology: 10-year retrospective analysis of 312 patients.

    PubMed

    Kilavuz, Ahmet Erdem; Songu, Murat; İmre, Abdulkadir; Arslanoğlu, Secil; Özkul, Yilmaz; Pinar, Ercan; Ateş, Düzgün

    2018-05-01

    The accuracy of fine-needle aspiration biopsy (FNAB) is controversial in parotid tumors. We aimed to compare FNAB results with the final histopathological diagnosis and to apply the "Sal classification" to our data and discuss its results and its place in parotid gland cytology. The FNAB cytological findings and final histological diagnosis were assessed retrospectively in 2 different scenarios based on the distribution of nondefinitive cytology, and we applied the Sal classification and determined malignancy rate, sensitivity, and specificity for each category. In 2 different scenarios FNAB sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were found to be 81%, 87%, 54.7%, and 96.1%; and 65.3%, 100%, 100%, and 96.1%, respectively. The malignancy rates and sensitivity and specificity were also calculated and discussed for each Sal category. We believe that the Sal classification has a great potential to be a useful tool in classification of parotid gland cytology. © 2018 Wiley Periodicals, Inc.

  1. The Mammotome biopsy system is an effective treatment strategy for breast abscess.

    PubMed

    Wang, Keren; Ye, Yuqin; Sun, Guang; Xu, Zheli

    2013-01-01

    Although most breast abscesses can be treated with the current first-line treatment of antibiotics by needle aspiration, the therapeutic duration is lengthy and recurrences often occur. Therefore, we aimed to investigate the clinical efficacy of the Mammotome biopsy system (Johnson & Johnson Corp., New Brunswick, NJ) in a cohort of patients with breast abscesses. Forty lactating and 30 nonlactating breast abscess patients with unfavorable outcomes with antibiotic treatment and/or needle aspiration failure were recruited and treated with the Mammotome biopsy system. Skin inflammation of all patients disappeared within 6 days with no recurrence. The clinical outcomes in patients with an abscess size ≤ 3.5 cm was significantly better than those with an abscess size >3.5 cm (P = .025). The Mammotome biopsy system, an effective treatment strategy that is minimally invasive and less damaging, in combination with appropriate antibiotic therapy can be used safely as the first-line approach to breast abscess management. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Hydatid cyst of parotid: Report of unusual cytological findings extending the cytomorphological spectrum.

    PubMed

    Arora, Vinod Kumar; Chopra, Neha; Singh, Poorva; Venugopal, Vasantha Kumar; Narang, Salil

    2016-09-01

    Hydatid disease is a zoonotic infestation caused by larval cestode of genus Echinococcus. Cystic form of this infection mostly involves liver and lung. Hydatid disease of the parotid gland is very rare even in endemic areas and is often clinically mistaken for parotid tumors or cysts. The presence of protoscolices, laminated membranes, and isolated hooklets are characteristic cytological features observed on fine-needle aspirate from hydatid cysts. We report unusual cytological features from a hydatid cyst of parotid in a 13-year-old girl. She presented with a slowly enlarging hard mass in left parotid. Fine-needle aspiration yielded slightly turbid fluid. Smears from the sediment revealed naked parasitic micronuclei, fragments of germinative layer (endocyst), and abortive brood capsules (buds from endocyst) seen as spherical structures with multiple parasitic nuclei. Some of these spherical structures were degenerated with recognizable nuclei and others were completely necrotic. Diagn. Cytopathol. 2016;44:770-773. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Cancer cell profiling by barcoding allows multiplexed protein analysis in fine-needle aspirates.

    PubMed

    Ullal, Adeeti V; Peterson, Vanessa; Agasti, Sarit S; Tuang, Suan; Juric, Dejan; Castro, Cesar M; Weissleder, Ralph

    2014-01-15

    Immunohistochemistry-based clinical diagnoses require invasive core biopsies and use a limited number of protein stains to identify and classify cancers. We introduce a technology that allows analysis of hundreds of proteins from minimally invasive fine-needle aspirates (FNAs), which contain much smaller numbers of cells than core biopsies. The method capitalizes on DNA-barcoded antibody sensing, where barcodes can be photocleaved and digitally detected without any amplification steps. After extensive benchmarking in cell lines, this method showed high reproducibility and achieved single-cell sensitivity. We used this approach to profile ~90 proteins in cells from FNAs and subsequently map patient heterogeneity at the protein level. Additionally, we demonstrate how the method could be used as a clinical tool to identify pathway responses to molecularly targeted drugs and to predict drug response in patient samples. This technique combines specificity with ease of use to offer a new tool for understanding human cancers and designing future clinical trials.

  4. Cancer cell profiling by barcoding allows multiplexed protein analysis in fine needle aspirates

    PubMed Central

    Ullal, Adeeti V.; Peterson, Vanessa; Agasti, Sarit S.; Tuang, Suan; Juric, Dejan; Castro, Cesar M.; Weissleder, Ralph

    2014-01-01

    Immunohistochemistry-based clinical diagnoses require invasive core biopsies and use a limited number of protein stains to identify and classify cancers. Here, we introduce a technology that allows analysis of hundreds of proteins from minimally invasive fine needle aspirates (FNA), which contain much smaller numbers of cells than core biopsies. The method capitalizes on DNA-barcoded antibody sensing where barcodes can be photo-cleaved and digitally detected without any amplification steps. Following extensive benchmarking in cell lines, this method showed high reproducibility and achieved single cell sensitivity. We used this approach to profile ~90 proteins in cells from FNAs and subsequently map patient heterogeneity at the protein level. Additionally, we demonstrate how the method could be used as a clinical tool to identify pathway responses to molecularly targeted drugs and to predict drug response in patient samples. This technique combines specificity with ease of use to offer a new tool for understanding human cancers and designing future clinical trials. PMID:24431113

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thanos, Loukas; Galani, Panagiota, E-mail: paga@hol.gr; Mylona, Sophia

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encounteredmore » were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure.« less

  6. Fine needle aspiration (FNA) of synovial sarcoma--a comparative histological-cytological study of 15 cases, including immunohistochemical, electron microscopic and cytogenetic examination and DNA-ploidy analysis.

    PubMed

    Akerman, M; Willén, H; Carlén, B; Mandahl, N; Mertens, F

    1996-06-01

    A retrospective study of 25 FNAs (11 aspirates from primary tumours and 14 from recurrencies and metastases) from 15 synovial sarcomas was performed. The cytological findings were correlated with the histopathology and the value of immunohistochemical and electron microscopic examination as well as DNA-ploidy and cytogenetic analysis for diagnosis were assessed. A reproducible cellular pattern with a reliable diagnosis of spindle cell sarcoma was possible provided that the aspirates were cell rich. However, a true biphasic pattern indicative of synovial sarcoma was only seen in one of the 25 specimens. Electron microscopic examination of the aspirates was a valuable adjunctive diagnostic method, whereas immunocytochemistry and DNA-ploidy analysis were not. Immunohistochemical, electron microscopic and cytogenetic analysis were all valuable ancillary methods when performed on surgical specimens. Malignant haemangiopericytoma and fibrosarcoma were the most important differential diagnoses in the FNA specimens.

  7. [Modern Management of Pancoast Tumour].

    PubMed

    Marra, Alessandro

    2018-06-01

    Pancoast or superior pulmonary sulcus tumour is a subset of lung carcinoma that invades the structures of the thoracic inlet - first ribs, distal roots of the brachial plexus, stellate ganglion, vertebrae, and subclavian vessels. The first symptom is usually shoulder pain; consequently, most patients are initially treated for osteoarthritis. Late diagnosis is common. Success of therapy depends on an accurate staging: standard imaging with CT scan of the chest, PET-CT scan, brain MRI are needed to rule out distant metastases, endobronchial ultrasound-guided needle biopsy (EBUS-TBNA) or mediastinoscopy are mandatory for reliable nodal staging. An MRI of the thoracic inlet allows to clearly define the boundaries of local invasion. Modern management of Pancoast tumour includes induction concurrent chemoradiotherapy followed by surgical resection. As compared with historical series treated by preoperative radiation, a trimodally approach did enhance complete resection rates and perhaps long-term survival - from about 30% 5-year survival rate to 60% in R0-resected patients. In patients who have unresectable but non-metastatic Pancoast tumours and appropriate performance status, definitive concurrent chemoradiotherapy and radiotherapy are recommended options. Georg Thieme Verlag KG Stuttgart · New York.

  8. Feasibility of obtaining breast epithelial cells from healthy women for studies of cellular proliferation.

    PubMed

    Miller, N A; Thomas, M; Martin, L J; Hedley, D W; Michal, S; Boyd, N F

    1997-05-01

    Increased dietary fat intake and rate of breast epithelial cell proliferation have each been associated with the development of breast cancer. The goal of this study was to measure the effect of a low fat, high carbohydrate diet on the rate of breast epithelial cell proliferation in women at high risk for breast cancer. Women were recruited from the intervention and control groups of a randomized low fat dietary intervention trial, breast epithelial cells were obtained by fine needle aspiration, and cell proliferation was assessed in these samples using immunofluorescent detection of Ki-67 and PCNA. The effects of needle size and study group on cell yield and cytologic features of the cells were also examined. Fifty three women (20 in the intervention group and 33 in the control group) underwent the biopsy procedure. Slides from 38 subjects were stained for Ki-67 and from 14 subjects for PCNA. No cell proliferation (fluorescence) was detected for either Ki-67 or PCNA in any of the slides. Epithelial cell yield and number of stromal fragments were greater with a larger needle size. Numbers of stromal fragments and bipolar naked nuclei were greater in the low fat as compared to the control group but no differences in epithelial cell yield were observed between the two groups. This study confirms that fine needle aspiration biopsy is a feasible method of obtaining epithelial cells from women without discrete breast masses, but suggests that cell proliferation cannot be assessed using Ki-67 and PCNA in such samples.

  9. Effects of repeated transvaginal aspiration of immature follicles on mare health and ovarian status.

    PubMed

    Velez, I C; Arnold, C; Jacobson, C C; Norris, J D; Choi, Y H; Edwards, J F; Hayden, S S; Hinrichs, K

    2012-12-01

    Transvaginal ultrasound-guided follicle aspiration (TVA) is performed clinically but there is little information available on complications associated with this procedure. It is possible that TVA is associated with damage to the ovary and may induce peritonitis or peritoneal adhesions. This study was conducted to determine the effect of repeated TVA on mare health and ovarian status. Thirty-two mares were used for oocyte recovery via repeated TVA over a 3 year period; different mares were used each year. In Year 1, ovarian status was monitored in 11 mares by transrectal palpation and ultrasonography. In Year 2, 6 of 11 mares underwent abdominocentesis and were examined by laparoscopy after one TVA and again after multiple TVAs. In Year 3, 10 mares underwent multiple TVAs with either a 15 or a 12 gauge needle and the ovaries were removed for examination. Four hundred and twenty-seven aspiration sessions (390 via TVA and 37 via needle placement through the flank) and 3202 follicle punctures (3161 TVA and 41 flank) were performed. One mare developed an ovarian abscess. Transient rectal bleeding was evident after 16% of TVA sessions. No adhesions were found on laparoscopic or gross examination of ovaries and there were minimal changes on histological evaluation. Follicle aspiration carries a small possibility (< 0.5%) of ovarian abscess formation. There is a possibility of rectal abrasion or puncture but little gross or histological damage to the ovary. These results provide a basis for using prophylactic administration of antibiotics after TVA and for advising mare owners of the rare but potential complications associated with the procedure.

  10. Clinical experience with aspiration of breast abscesses based on size and etiology at an academic medical center.

    PubMed

    Giess, Catherine S; Golshan, Mehra; Flaherty, Karen; Birdwell, Robyn L

    2014-01-01

    Our purpose was to review needle aspiration of breast abscesses and identify factors associated with treatment by aspiration alone versus aspiration with surgical incision and drainage (I/D). This Institutional Review Board-approved, retrospective review of the breast ultrasound database from 2008 to 2010 identified 40 patients (41 abscesses) who underwent aspiration, with or without I/D. Demographics, imaging, number of aspirations, and microbiology were reviewed. Twenty-two abscesses underwent aspiration only, 16 > 3 cm, 6 ≤ 3 cm (mean 4.3 cm, range 0.9-10 cm). Known risk factors included lactational (11), 3 weeks post partum (1), pregnancy (1), recent biopsy/lumpectomy (5). Nineteen abscesses underwent aspiration and I/D, 15 > 3 cm, 4 ≤ 3 cm (mean 4.1 cm, range 2.2-7.5 cm). Known risk factors included lactational (4), recurrent subareolar abscess (4), diabetes (3), hydradenitis suppuritiva (1), nipple piercing (2), smoking (1), pregnancy (1), HIV (1), and lumpectomy (1). Identified reasons for I/D included lack of improvement/recurrence (12), fistula (3), and one electively after clinical improvement of a recurrent subareolar abscess. Abscesses associated with pregnancy and lactation or breast biopsy are effectively managed with aspiration, even when large. Recurrence, chronicity, or fistula may require surgical intervention. © 2014 Wiley Periodicals, Inc.

  11. The use of the 25 Sprotte needle markedly reduces post-dural puncture headache in routine neurological practice.

    PubMed

    Bertolotto, Antonio; Malentacchi, Maria; Capobianco, Marco; di Sapio, Alessia; Malucchi, Simona; Motuzova, Yana; Pulizzi, Annalisa; Berchialla, Paola; Sperli, Francesca

    2016-02-01

    The objectives of this article are to test the feasibility of lumbar puncture (LP) using 25-gauge (G) needles in daily neurological practice and to compare the risk of post-dural puncture headache (PDPH) with four types of needles. In a prospective rater-blind study, pros and cons of four different LP needles, the 20G Quincke (20Q), 22G Sprotte (22S), 25G Whitacre (25W) and 25G Sprotte (25S), were evaluated in 394 LPs performed by seven neurologists. The neurologist performing the LP recorded the type and size of needle, intensity of pain, safety, time of the procedure and failure or success. Between five and 15 days later another neurologist, blind to the type of needle used, completed an ad-hoc questionnaire for PDPH. PDPH developed in 35.9% patients when using a 20Q needle, and in 12.9%, 6.8% and 1.6%, respectively, when using a 22S, 25W or 25S needle. The difference in incidence of PDPH following LP performed with the 20Q needle and the 25S or 22S was statistically significant (p < 0.001 and p = 0.008, respectively) and it approached significance when comparing the 25S and 25W (p = 0.06). As 25W and 25S needles need CSF aspiration, LP requires more time and skill. Pain caused by LP was similar with the four needles. The use of the 25S needle in diagnostic LP reduces the frequency and severity of PDPH. © International Headache Society 2015.

  12. A Promising Approach to Addressing America's Biggest Challenges. Needle-Moving Community Collaboratives

    ERIC Educational Resources Information Center

    Jolin, Michele; Schmitz, Paul; Seldon, Willa

    2012-01-01

    Communities face powerful challenges--a high-school dropout epidemic, youth unemployment, teen pregnancy--that require powerful solutions. In a climate of increasingly constrained resources, those solutions must help communities to achieve more with less. A new kind of community collaborative--an approach that aspires to significant,…

  13. Case Study: Chicago. Needle-Moving Community Collaboratives

    ERIC Educational Resources Information Center

    Seldon, Willa; Jolin, Michele; Schmitz, Paul

    2012-01-01

    Communities face powerful challenges that require powerful solutions: a high-school dropout epidemic, youth unemployment, teen pregnancy. In an era of limited resources, those solutions must help communities to achieve more with less. A new kind of community collaborative--an approach that aspires to significant community-wide progress by…

  14. Case Study: Philadelphia. Needle-Moving Community Collaboratives

    ERIC Educational Resources Information Center

    Seldon, Willa; Jolin, Michele; Schmitz, Paul

    2012-01-01

    Communities face powerful challenges that require powerful solutions: a high-school dropout epidemic, youth unemployment, teen pregnancy. In an era of limited resources, those solutions must help communities to achieve more with less. A new kind of community collaborative--an approach that aspires to significant community-wide progress by…

  15. Case Study: Cincinnati, Covington, and Newport. Needle-Moving Community Collaboratives

    ERIC Educational Resources Information Center

    Seldon, Willa; Jolin, Michele; Schmitz, Paul

    2012-01-01

    Communities face powerful challenges that require powerful solutions: a high-school dropout epidemic, youth unemployment, teen pregnancy. In an era of limited resources, those solutions must help communities to achieve more with less. A new kind of community collaborative--an approach that aspires to significant community-wide progress by…

  16. Case Study: Nashville. Needle-Moving Community Collaboratives

    ERIC Educational Resources Information Center

    Seldon, Willa; Jolin, Michele; Schmitz, Paul

    2012-01-01

    Communities face powerful challenges that require powerful solutions: a high-school dropout epidemic, youth unemployment, teen pregnancy. In an era of limited resources, those solutions must help communities to achieve more with less. A new kind of community collaborative--an approach that aspires to significant community-wide progress by…

  17. Case Study: Parramore. Needle-Moving Community Collaboratives

    ERIC Educational Resources Information Center

    Seldon, Willa; Jolin, Michele; Schmitz, Paul

    2012-01-01

    Communities face powerful challenges that require powerful solutions: a high-school dropout epidemic, youth unemployment, teen pregnancy. In an era of limited resources, those solutions must help communities to achieve more with less. A new kind of community collaborative--an approach that aspires to significant community-wide progress by…

  18. Galactocele in a Prepubertal Girl.

    PubMed

    Alaniz, Veronica I; Jeudy, Myrlene; Pearlman, Mark; Quint, Elisabeth H

    2017-08-01

    Galactoceles have been previously described as an unusual cause of benign breast enlargement in male infants and children. A 3-year-old prepubertal girl presented with a right-sided breast mass and was found to have a 4.4-cm hypoechoic cyst on ultrasound imaging with otherwise normal endocrine studies including prolactin levels. She underwent cyst aspiration which revealed milky fluid. Fat globules were identified with microscopic examination, confirming the diagnosis of a galactocele. Aspiration resolved the mass. The etiology of galactoceles in nonlactating women is poorly understood. Traditionally, treatment of these benign cysts in male children has been surgical excision. In prepubertal girls, conservative management by surveillance or needle aspiration is warranted to prevent damage to developing breast tissue. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  19. Midkine and pleiotrophin concentrations in needle biopsies of breast and lung masses.

    PubMed

    Giamanco, Nicole M; Jee, Youn Hee; Wellstein, Anton; Shriver, Craig D; Summers, Thomas A; Baron, Jeffrey

    2017-09-07

    Midkine (MDK) and pleiotrophin (PTN) are two closely related heparin-binding growth factors which are overexpressed in a wide variety of human cancers. We hypothesized that the concentrations of these factors in washout of biopsy needles would be higher in breast and lung cancer than in benign lesions. Seventy subjects underwent pre-operative core needle biopsies of 78 breast masses (16 malignancies). In 11 subjects, fine needle aspiration was performed ex vivo on 7 non-small cell lung cancers and 11 normal lung specimens within surgically excised lung tissue. The biopsy needle was washed with buffer for immunoassay. The MDK/DNA and the PTN/DNA ratio in most of the malignant breast masses were similar to the ratios in benign masses except one lobular carcinoma in situ (24-fold higher PTN/DNA ratio than the average benign mass). The MDK/DNA and PTN/DNA ratio were similar in most malignant and normal lung tissue except one squamous cell carcinoma (38-fold higher MDK/DNA ratio than the average of normal lung tissue). Both MDK and PTN are readily measurable in washout of needle biopsy samples from breast and lung masses and levels are highly elevated only in a specific subset of these malignancies.

  20. Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application

    NASA Technical Reports Server (NTRS)

    Armstrong, G.; Cardon, L.; Vilkomerson, D.; Lipson, D.; Wong, J.; Rodriguez, L. L.; Thomas, J. D.; Griffin, B. P.

    2001-01-01

    This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.

  1. ADM3, TFF3 and LGALS3 are discriminative molecular markers in fine-needle aspiration biopsies of benign and malignant thyroid tumours

    PubMed Central

    Karger, S; Krause, K; Gutknecht, M; Schierle, K; Graf, D; Steinert, F; Dralle, H; Führer, D

    2012-01-01

    Background: Previously, we reported a six-marker gene set, which allowed a molecular discrimination of benign and malignant thyroid tumours. Now, we evaluated these markers in fine-needle aspiration biopsies (FNAB) in a prospective, independent series of thyroid tumours with proven histological outcome. Methods: Quantitative RT–PCR was performed (ADM3, HGD1, LGALS3, PLAB, TFF3, TG) in the needle wash-out of 156 FNAB of follicular adenoma (FA), adenomatous nodules, follicular and papillary thyroid cancers (TC) and normal thyroid tissues (NT). Results: Significant expression differences were found for TFF3, HGD1, ADM3 and LGALS3 in FNAB of TC compared with benign thyroid nodules and NT. Using two-marker gene sets, a specific FNAB distinction of benign and malignant tumours was achieved with negative predictive values (NPV) up to 0.78 and positive predictive values (PPV) up to 0.84. Two FNAB marker gene combinations (ADM3/TFF3; ADM3/ACTB) allowed the distinction of FA and malignant follicular neoplasia with NPV up to 0.94 and PPV up to 0.86. Conclusion: We demonstrate that molecular FNAB diagnosis of benign and malignant thyroid tumours including follicular neoplasia is possible with recently identified marker gene combinations. We propose multi-centre FNAB studies on these markers to bring this promising diagnostic tool closer to clinical practice. PMID:22223087

  2. Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study

    NASA Astrophysics Data System (ADS)

    Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; van Gerven, P.; Bonsing, Bert A.; Sven Mieog, J.; Amelink, Arjen; Veselic, Maud; Morreau, Hans; van de Velde, Cornelis J. H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Robinson, Dominic J.; Vahrmeijer, Alexander L.

    2017-02-01

    Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ˜5 min. An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p=0.038; 166 μmol/L versus 17 μmol/L, p=0.039, respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.

  3. Fine needle aspiration cytology in lymphadenopathy of HIV-positive cases.

    PubMed

    Saikia, U N; Dey, P; Jindal, B; Saikia, B

    2001-01-01

    To evaluate the role of fine needle aspiration biopsy (FNAB) material in 25 HIV-positive cases with lymphadenopathy. We selected 25 cases for the present study who were enzyme-linked immunosorbent assay positive for HIV (HIV-1). FNAB was performed as a routine, outdoor procedure with informed consent of the patient. For each case, along with routine May-Grünwald-Giemsa and hematoxylin and eosin staining, Ziehl-Neelsen staining for acid-fast bacilli and periodic acid-Schiff staining for fungi were performed wherever necessary. A total of 28 sites were aspirated from 25 HIV patients. All these patients were heterosexual, and none had a history of drug abuse. FNAB was performed under ultrasound guidance in all four cases of a retroperitoneal group of lymph nodes. The most common FNAB diagnosis was reactive lymphoid hyperplasia (10), followed by tuberculosis (8). There were three cases diagnosed as fungal infection (two, Cryptococcus; one, histoplasmosis). FNAB of a case of lymph node was suggestive of tuberculosis. There was one case each diagnosed as non-Hodgkin's lymphoma and squamous cell carcinoma (metastatic). One case of a small axillary lymph node did not yield representative material. FNAB is a relatively inexpensive initial investigative technique in the diagnosis and management of HIV-positive patients. It can obviate the need for surgical excision and enable immediate treatment of specific infections.

  4. Fine needle aspiration biopsy of three cases of squamous cell carcinoma presenting as a thyroid mass: cytological findings and differential diagnosis.

    PubMed

    Rosa, M; Toronczyk, K

    2012-02-01

    Primary squamous cell carcinomas of the thyroid gland are extremely rare, comprising about 1% of thyroid malignancies. Although squamous cell carcinomas are readily identified as such on aspiration cytology in the majority of cases, the differentiation of primary versus metastatic tumour might not always be easy. Herein, we report three cases of squamous cell carcinomas involving the thyroid gland. Fine needle aspiration cytology (FNAC) was performed in three patients with a thyroid mass using standard guidelines. Smears were stained with Diff-Quik and Papanicolaou stains. Two patients were male and one was female, aged 59, 45 and 35 years, respectively. In all three patients a thyroid mass was present. FNAC smears in all cases showed cytological features of squamous cell carcinoma including keratinization and necrosis. After clinical and cytological correlation, one case appeared to be primary, one case metastatic, and in the third case no additional clinical information or biopsy follow-up was available for further characterization. Because primary squamous cell carcinoma of the thyroid is a rare finding, metastatic squamous cell carcinoma should always be excluded first. Metastatic disease usually presents in the setting of widespread malignancy, therefore a dedicated clinical and radiological investigation is necessary in these cases. In both clinical scenarios the patient's prognosis is poor. © 2010 Blackwell Publishing Ltd.

  5. Impact of Type of Needle on Incidence of Intravascular Injection During Diagnostic Lumbar Medial Branch Block.

    PubMed

    Joo, Young; Kim, Yong Chul; Lee, Sang Chul; Kim, Hye Young; Park, Keun Suk; Choi, Eun Joo; Moon, Jee Youn

    2016-01-01

    Intravascular (IV) injection of local anesthetics is a potential cause of false-negative results after lumbar medial branch nerve blockade (L-MBB) performed to diagnose facetogenic back pain. The aim of the present study was to identify the relationship between the needle type and the incidence of IV injection in patients undergoing L-MBB using fluoroscopy with digital subtraction imaging (DSI). In this prospective randomized study, we compared the incidence of IV uptake of contrast medium using the Quincke needle and Whitacre needle under real-time DSI during L-MBB. Clinical and demographic factors associated with the occurrence of IV uptake were also investigated. In total, 126 patients were randomized into the Quincke needle group (n = 62) and Whitacre needle group (n = 64). Intravascular uptake of contrast medium was observed in 66 (9.8%) of 671 L-MBB procedures under DSI. The incidence of IV uptake was 13.9% (47/338) using the Quincke needle and 5.7% (19/333) using the Whitacre needle. In the multivariate generalized estimating equations analysis, use of a Quincke needle was related to positive IV injection at a 1.898-fold higher rate than was use of a Whitacre needle (95% confidence interval, 1.025-3.516) and a positive aspiration test predicted IV injection at a 21.735-fold higher rate (95% confidence interval, 11.996-52.258). Lumbar medial branch nerve blockade using the Quincke needle was associated with a 1.9-fold higher rate of IV injection than was L-MBB using the Whitacre needle under DSI. Although further study is needed to confirm the clinical efficacy, Whitacre needles can be considered to reduce the risk of IV injection during L-MBB.

  6. The cytomorphologic spectrum of Wilms tumour on fine needle aspiration: a single institutional experience of 110 cases.

    PubMed

    Nayak, A; Iyer, V K; Agarwala, S

    2011-02-01

    To analyse the cytomorphologic spectrum of Wilms tumour (WT) on aspirates, the largest series reported to date. Adequate aspirates from paediatric renal tumours over a period of 17 years were reviewed and selected if subsequent excision showed WT or aspirates were diagnostic for WT and clinical/radiological evidence consistent with that diagnosis. Smears were re-examined for the proportion of components, degree of pleomorphism and mitosis. Of 110 aspirates, smears were triphasic in 44 (40.0%), biphasic (blastema and tubules) in 36 (32.7%) and monophasic (blastema alone) in 30 (27.3%). Stromal predominance was seen in 11 aspirates (10.0%) and five showed rhabdomyoblastic differentiation; all 11 were triphasic. Mean mitotic rate was 9.3/5000 cells (range 4-39/5000). Nuclear atypia not amounting to anaplasia and without atypical mitoses was seen in 15 (13.6%); these presented diagnostic problems. Two aspirates (1.8%) were considered anaplastic (unfavourable), both having atypical mitoses. Criteria similar to histology (i.e. 3-fold or more variation in nuclear size, marked hyperchromasia with bizarre nuclei and atypical mitoses in a biphasic or triphasic aspirate) helped in distinguishing anaplastic WT. Histopathological correlation in 67 cases showed good correlation of blastemal predominance, stromal predominance and anaplastic histology with the corresponding cytology. However, 9/27 (33.3%) triphasic tumours had only blastemal cells on corresponding aspiration because of sampling error. Cytokeratin was positive in 4 of 20 aspirates with blastema alone. Aspirates from WT were triphasic or biphasic in the majority (72.7%), permitting cytological diagnosis, which was improved by cytokeratin immunocytochemistry. Blastemal and stromal predominance on histology correlated well with cytology, but many triphasic tumours showed only blastema on aspiration. Anaplastic WT can be detected on aspirates using criteria similar to histology. © 2010 Blackwell Publishing Ltd.

  7. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    PubMed

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  8. Pistol-grip Syringe holder (Cameco syringe pistol) in fine needle aspiration Biopsy: any advantages over the use of direct finger grip?

    PubMed

    Mayun, A A; Nggada, H A; Abdulazzez, J O; Musa, A B; Pindiga, U H; Khalil, M I

    2013-06-01

    The study seeks to determine the advantages of using the pistol-grip syringe holder in the performance of FNAB over the use of direct finger grip method. The skin is cleaned with gauze soaked in methylated spirit and the lump is located and firmly held between the thumb and fore finger of the free hand. The syringe is held by the out side of the barrel or by pistol-grip, and the needle tip pushed into the lesion. The plunger is partially retracted, creating a negative pressure. The cutting edge of the needle tip frees the cells inside the lesion which are sucked into the fine bore of the needle. The contents of the needle are then emptied on a microscopic slide and thinly smeared. The slides are then fixed in alcohol and later stained. These were examined under the microscope and a comparison between the aspirations using pistol-grip and direct finger grip was made. A total of 266 cases of FNABs were carried out from 1st January to 31st December, 2008. There were 89 breast cases out of which 42 (47%) had pistol-grip method and 47 (53%) had direct finger grip method; 74 thyroid cases out of which 28 (38%) were pistol-grip and 46 (62%) were direct finger grip cases; 56 cases of lymph node FNABs of which 18(32%) and 38 (68%) had pistol-grip and direct finger grip methods respectively. There were 23 cases of salivary gland FNABs having 8 (35%) and 15 (65%) as pistol-grip and direct finger grip methods respectively. Marked cellularity was observed in the majority of cases using both methods of FNABs. This study has shown that the use of pistol-grip syringe holder in the performance of FNABs has no significant advantage compared to the direct finger grip method.

  9. The cost-effectiveness of fine-needle aspiration cytology and 14-gauge core needle biopsy compared with open surgical biopsy in the diagnosis of breast carcinoma.

    PubMed

    Logan-Young, W; Dawson, A E; Wilbur, D C; Avila, E E; Tomkiewicz, Z M; Sheils, L A; Laczin, J A; Taylor, A S

    1998-05-15

    Judicious utilization of fine-needle aspiration cytology (FNAC) and 14-gauge core needle biopsy (CB) theoretically should result in greater accuracy in breast carcinoma diagnosis and fewer unnecessary open surgical biopsies (OSBs), thus lowering health care costs. In 1995 in Rochester, New York, the ratio of open surgical breast biopsies per each verified breast carcinoma (OSB/Ca) in a freestanding breast clinic (EWBC) was compared with the OSB/Ca ratio of all physicians in the remainder of the city. The EWBC differs from all other diagnostic facilities in Rochester in that it routinely performs FNAC and CB. The EWBC recommended 462 OSBs resulting in 310 verified carcinomas, for a OSB/Ca ratio of 1.5. The physicians in the remainder of the city recommended 2036 OSBs resulting in 513 verified carcinomas, for a OSB/Ca ratio of 4.0. If the EWBC OSB/Ca ratio had been identical to the remainder of the city, the number of extra OSBs recommended by the clinic would have been 778, resulting in an additional cost of $1,712,082. When the added cost of the 2594 FNACs ($256,285) and 403 CBs ($252,278) performed by the clinic was subtracted from the $1,712,082, the freestanding breast clinic cost savings was $1,203,519. The lymph node metastasis rate of 19% for the breast carcinomas diagnosed in clinic patients was identical to that of the women with breast carcinoma in the remainder of the city. Utilization of FNAC and CB allows radiologists to lower their OSB/Ca ratio without sacrificing early detection. In this study, these less expensive procedures result in lowered medical costs for the health care system.

  10. High-resolution endoscopic ultrasound imaging and the number of needle passages are significant factors predicting high yield of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses without an on-site cytopathologist

    PubMed Central

    Jeong, Seok Hoo; Yoon, Hyun Hwa; Kim, Eui Joo; Kim, Yoon Jae; Kim, Yeon Suk; Cho, Jae Hee

    2017-01-01

    Abstract Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the accurate diagnostic method for pancreatic masses and its accuracy is affected by various FNA methods and EUS equipment. Therefore, we aimed to elucidate the instrumental and methodologic factors for determining the diagnostic yield of EUS-FNA for pancreatic solid masses without an on-site cytopathology evaluation. We retrospectively reviewed the medical records of 260 patients (265 pancreatic solid masses) who underwent EUS-FNA. We compared historical conventional EUS groups with high-resolution imaging devices and finally analyzed various factors affecting EUS-FNA accuracy. In total, 265 pancreatic solid masses of 260 patients were included in this study. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNA for pancreatic solid masses without on-site cytopathology evaluation were 83.4%, 81.8%, 100.0%, 100.0%, and 34.3%, respectively. In comparison with conventional image group, high-resolution image group showed the increased accuracy, sensitivity and specificity of EUS-FNA (71.3% vs 92.7%, 68.9% vs 91.9%, and 100% vs 100%, respectively). On the multivariate analysis with various instrumental and methodologic factors, high-resolution imaging (P = 0.040, odds ratio = 3.28) and 3 or more needle passes (P = 0.039, odds ratio = 2.41) were important factors affecting diagnostic yield of pancreatic solid masses. High-resolution imaging and 3 or more passes were the most significant factors influencing diagnostic yield of EUS-FNA in patients with pancreatic solid masses without an on-site cytopathologist. PMID:28079803

  11. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  12. Comparison of Core-Needle Biopsy and Fine-Needle Aspiration for Evaluating Thyroid Incidentalomas Detected by 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: A Propensity Score Analysis.

    PubMed

    Suh, Chong Hyun; Choi, Young Jun; Lee, Jong Jin; Shim, Woo Hyun; Baek, Jung Hwan; Chung, Han Cheol; Shong, Young Kee; Song, Dong Eun; Sung, Tae Yon; Lee, Jeong Hyun

    2017-10-01

    This study used a propensity score analysis to assess the roles of core-needle biopsy (CNB) and fine-needle aspiration (FNA) in the evaluation of thyroid incidentalomas detected on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). The study population was obtained from a historical cohort who underwent 18 F-FDG PET/CT between October 2008 and September 2015. Patients were included who underwent ultrasound-guided CNB or FNA for incidental focal uptake of 18 F-FDG in the thyroid gland on PET/CT. The primary study outcomes included the inconclusive result rates in the CNB and FNA groups. The secondary outcome measures included the non-diagnostic result rate and the diagnostic performance for neoplasms. Multivariate analysis, propensity score matching, and inverse probability weighting were conducted. A total of 1360 nodules from 1338 patients were included in this study: 859 nodules from 850 patients underwent FNA, and 501 nodules from 488 patients underwent CNB. Compared to FNA, CNB demonstrated a significantly lower inconclusive result rate in the pooled cohort (23.8% vs. 35.4%; p < 0.001), propensity score-matched cohorts (22.9% vs. 36.6%; p < 0.001), and with inverse probability weighting (22.4% vs. 35.2%; p < 0.001). Non-diagnostic result rates were also significantly lower in CNB than in FNA. The diagnostic performance of the two groups in the pooled and matched cohorts was similar, with no significant differences found. The significantly lower inconclusive result rates in CNB than in FNA were consistent within the propensity score-matched cohorts. Therefore, CNB appears to be a promising diagnostic tool for patients with thyroid incidentalomas detected on 18 F-FDG PET/CT.

  13. Utility of shear wave elastography to detect papillary thyroid carcinoma in thyroid nodules: efficacy of the standard deviation elasticity.

    PubMed

    Kim, Hye Jeong; Kwak, Mi Kyung; Choi, In Ho; Jin, So-Young; Park, Hyeong Kyu; Byun, Dong Won; Suh, Kyoil; Yoo, Myung Hi

    2018-02-23

    The aim of this study was to address the role of the elasticity index as a possible predictive marker for detecting papillary thyroid carcinoma (PTC) and quantitatively assess shear wave elastography (SWE) as a tool for differentiating PTC from benign thyroid nodules. One hundred and nineteen patients with thyroid nodules undergoing SWE before ultrasound-guided fine needle aspiration and core needle biopsy were analyzed. The mean (EMean), minimum (EMin), maximum (EMax), and standard deviation (ESD) of SWE elasticity indices were measured. Among 105 nodules, 14 were PTC and 91 were benign. The EMean, EMin, and EMax values were significantly higher in PTCs than benign nodules (EMean 37.4 in PTC vs. 23.7 in benign nodules, p = 0.005; EMin 27.9 vs. 17.8, p = 0.034; EMax 46.7 vs. 31.5, p < 0.001). The EMean, EMin, and EMax were significantly associated with PTC with diagnostic odds ratios varying from 6.74 to 9.91, high specificities (86.4%, 86.4%, and 88.1%, respectively), and positive likelihood ratios (4.21, 3.69, and 4.82, respectively). The ESD values were significantly higher in PTC than in benign nodules (6.3 vs. 2.6, p < 0.001). ESD had the highest specificity (96.6%) when applied with a cut-off value of 6.5 kPa. It had a positive likelihood ratio of 14.75 and a diagnostic odds ratio of 28.50. The shear elasticity index of ESD, with higher likelihood ratios for PTC, will probably identify nodules that have a high potential for malignancy. It may help to identify and select malignant nodules, while reducing unnecessary fine needle aspiration and core needle biopsies of benign nodules.

  14. Differentiating benign from malignant thyroid nodules using micro ribonucleic acid amplification in residual cells obtained by fine needle aspiration biopsy.

    PubMed

    Mazeh, Haggi; Levy, Yair; Mizrahi, Ido; Appelbaum, Liat; Ilyayev, Nadia; Halle, David; Freund, Herbert R; Nissan, Aviram

    2013-04-01

    Fine needle aspiration biopsy (FNAB) is the most commonly used diagnostic tool to differentiate benign from malignant thyroid nodules. Nevertheless, some FNAB cytology results are not definite. In such cases diagnostic thyroid lobectomy is performed with malignancy rate on final histopathology ranging at 15%-75%. The aim of this study was to improve on the accuracy of FNAB-based cytology by amplification of microRNAs (micro ribonucleic acids [miRs]) from the residual cells left in the FNAB needle after submission for cytology. Residual cells were collected from the needle cup after FNAB cytology of 77 consecutive patients with thyroid nodules. miR-enriched RNA was extracted for all patients with cytology showing either follicular lesion or suspicion for malignancy (n=11). The expression of miR-21, -31, -146b, -187, -221, and -222 was determined using real-time polymerase chain reaction. Results were compared with final surgical histopathology. RNA was successfully extracted from all FNAB specimens. Five patients had FNAB cytology suspicious for malignancy. The miR panel was positive in all five (100%). Six patients had follicular lesions on FNAB. The miR panel was positive in three of four patients (75%) with confirmed malignancy and was negative in two of two (0%) patients with benign pathology results. This corresponded to a specificity of 100%, sensitivity of 88%, and accuracy of 90%. RNA extraction from FNAB residual cells is feasible, and a miR panel amplified from the extracted RNA seems like a promising diagnostic tool in this limited number of patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    PubMed

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  16. A technique to improve diagnostic information from fine-needle aspirations: immunohistochemistry on cytoscrape.

    PubMed

    Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie; Linnemann, Dorte

    2009-04-25

    Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metastases has therapeutic impact. However, the distinction between these groups may be difficult on smears. In this report, the authors describe a simple method, called cytoscrape (CS), which can be used on virtually any smear to produce material useful for ancillary methods, including immunohistochemistry. Aspirates from 47 patients who had possible malignant infiltrates identified on computed tomography scans of the chest were included. Smears were stained by May-Grunwald-Giemsa and Diff-Quick for diagnostic purposes. CS material was obtained by gently scraping cells off the slides. Clots were made, and the sections were stained for thyroid transcription factor-1 (TTF-1) and mucin. The utility of the CS technique was evaluated by assessing the sensitivity and specificity of the method and by quantifying the extra diagnostic information obtained by the method relative to smears alone. Malignant tumor cells in the CS material were identified in 43 aspirates (91%). Both the sensitivity and the specificity for TTF-1 were 100%. The sensitivity for mucin was 60%, and the specificity for mucin was 100%. The diagnoses made on smears were improved by CS in 31 patients (72%), in that more precise separation of subgroups of NSCLC was possible or information on primary tumors was obtained. The CS technique improved the diagnostic information from FNA in a clinically relevant way. The method is simple, quick, and inexpensive. (c) 2009 American Cancer Society.

  17. Hormones, Women and Breast Cancer

    MedlinePlus

    ... sure that it is benign (not cancer). These tests can include • A mammogram • A breast ultrasound • A sample of cells from the lump (called a fine needle aspirate) • A sample of a piece of tissue from the lump (called a core biopsy) Possible Symptoms of Breast Cancer • A lump • ...

  18. Epidemiology and Control of Malaria, Leishmaniasis and Schistosomiasis in Brazil

    DTIC Science & Technology

    1991-02-15

    using a 22 gauge needle. The aspirates were inoculated onto NNN media overlaid with 0.9% NaCl with Gentamyacin and . Penicillin /Streptomyosin, and...13-16. 2. Chulay JD, Oster CN, McGreevy PB, Hendricks LD, Kreutzer RD, 1988. American cutaneous leishmaniasis. Rev Soc Brasileira Med Trop 21 165-72

  19. Spontaneous Pneumothorax in the USAF Aircrew Population: A Retrospective Study.

    DTIC Science & Technology

    1986-10-01

    PROGRAM PROjECT ITASK WORK UNIT i oroc Is Ai r Force Base, TFX 78235-530Dl ELEMENT NO No NO ACCESSiON NO ITiTLE (include Security Classification) incrat...Needle aspiration plus surgery Chsest tube. oxygen, and sufer ’ program. there are no firm guidelines regarding aviation rates were lower than those

  20. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    PubMed Central

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  1. Clinical Study of Second Branchial Cleft Anomalies.

    PubMed

    Lee, Dong Hoon; Yoon, Tae Mi; Lee, Joon Kyoo; Lim, Sang Chul

    2018-03-30

    The objective of this study was to review the clinical characteristics and surgical treatment outcomes of second branchial cleft anomalies, and to evaluate the usefulness and accuracy of preoperative fine-needle aspiration cytology (FNAC) in the diagnosis of branchial cleft cysts. A retrospective chart review was performed at Chonnam National University Hwasun Hospital from January 2010 to December 2016. Among 25 patients with second branchial cleft anomalies, in 23 patients (92.0%), these anomalies presented as cysts, and in the remaining 2 patients (8.0%), these anomalies presented as fistulas. Fine-needle aspiration cytology had a diagnostic sensitivity of 100%, a positive-predictive value of 100%, and accuracy of 100% for diagnosing second branchial cleft cyst. All patients of second branchial cleft anomalies were treated surgically under general anesthesia. No recurrence of second branchial cleft anomalies was observed. Branchial cleft cysts were the most common type of second branchial cleft anomalies. Preoperative FNAC is a useful and accurate method for preoperative evaluation of branchial cleft cysts. Surgical excision of second branchial cleft anomalies is the treatment of choice without any complications and with no recurrence.

  2. Thyroid Fine Needle Aspiration Biopsies in Children: Study of Cytological-Histological Correlation and Immunostaining with Thyroid Peroxidase Monoclonal Antibodies

    PubMed Central

    Hoperia, Victoria; Larin, Alexander; Jensen, Kirk; Bauer, Andrew; Vasko, Vasily

    2010-01-01

    Context. There is limited data comparing results of fine needle aspiration biopsies (FNABs) to histological diagnosis in children. Design. FNABs were performed in 707 children and cytological results were compared to histology in 165 cases. The usefulness of immunostaining with anti-TPO monoclonal antibodies (MoAb47) on FNAB samples was examined in 54 operated patients. Results. Among unsatisfactory, benign, suspicious, and malignant FNAB, the histological diagnoses were benign in 12/12 (100%), 69/70 (98.5%), 40/50 (80.0%), and 0/33 (0%), respectively. After surgery, malignancy was established in 44/165 (26.6%) cases. The sensitivity, specificity, and positive and negative predictive values were 95.4%, 55.8%, 61.7%, and 95% with standard FNAB; and 100%, 75%, 73.3, and 100% with MoAb47. Among suspicious FNAB, positive MoAb47 staining was a reliable marker for exclusion of malignancy. Conclusion. Benign and malignant FNAB accurately predict histological diagnosis. In suspicious FNAB, MoAb47 immunostaining may be a useful adjunct to standard cytology. PMID:20652042

  3. Secondary tumors involving the thyroid gland: A multi-institutional analysis of 28 cases diagnosed on fine-needle aspiration.

    PubMed

    HooKim, Kim; Gaitor, Jennifer; Lin, Oscar; Reid, Michelle D

    2015-11-01

    Fine-needle aspiration (FNA) is routinely used to evaluate primary thyroid lesions (PTLs), however, its role in diagnosing secondary thyroid neoplasms (STNs) has not been extensively studied. The goal was to examine the clinical and cytopathologic features of STNs diagnosed on FNA. The clinico-pathologic features of 28 STNs were analyzed. All PTLs, lymphomas, and locally invasive tumors were excluded. There were 28 STNs (0.18% incidence) out of 15,800 thyroid FNAs (12 males, 16 females, 32 - 85 years), all occurring metachronously (3 weeks-20 years, average 78.3 months) comprising 24 (85.7%) metastatic carcinomas (14 [50%] renal; 4 [14.3%] head and neck squamous cell carcinomas, 3 [10.7%] breast, and 1 [3.6%] colorectal, uterine serous carcinoma, and lung adenosquamous carcinoma, respectively), 3 sarcomas (10.7%) and 1 melanoma (3.6%). STNs are rare and diverse tumors which may occur decades after primary malignancy. Renal carcinomas are the most common. Prior history of malignancy, high index of suspicion, and attention to key distinguishing cytologic clues are critical for accurate diagnosis. © 2015 Wiley Periodicals, Inc.

  4. Comparative study between ultrasound-guided fine needle aspiration cytology of axillary lymph nodes and sentinel lymph node histopathology in early-stage breast cancer

    PubMed Central

    Cardoso-Coelho, Lívio Portela; Borges, Rafael Soares; Alencar, Airlane Pereira; Cardoso-Campos-Verdes, Larysse Maira; da Silva-Sampaio, João Paulo; Borges, Umbelina Soares; Gebrim, Luiz Henrique; da Silva, Benedito Borges

    2017-01-01

    The replacement of sentinel lymph node biopsy (SNB) by ultrasound-guided fine-needle aspiration (US-guided FNA) cytology of axillary lymph nodes is controversial, despite the simplicity and reduced cost of the latter. In the present study, US-guided FNA was performed in 27 patients with early-stage breast cancer for comparison with SNB. Data were analyzed by calculation of sample proportions. Tumor subtypes included invasive ductal carcinoma (85%), invasive lobular carcinoma (7%), and tubular and metaplastic carcinoma (4%). FNA had a sensitivity of 45%, specificity of 100%, positive predictive value of 100% and a negative predictive value of 73%. Axillary lymph node cytology obtained by US guided-FNA in patients with breast cancer had a specificity similar to that of sentinel lymph node histopathology in the presence of axillary node metastases. However, when lymph node cytology is negative, it does not exclude the existence of metastatic implants, due to its low sensitivity in comparison to sentinel lymph node histopathology. PMID:28521436

  5. Cytology of primary vaginal melanoma: An unusual report on fine needle aspiration.

    PubMed

    Agarwal, Poojan; Kaushal, Manju

    2017-03-01

    Primary malignant melanoma of the vagina is an extremely uncommon malignancy comprising of less than 10% malignancies of the female genital tract and 0.3% of all melanomas. Melanoblasts are neural crest derivatives and are notorious for causing primary cutaneous neoplasms. However, they involve virtually every organ of the body including eye, intestines and ocular mucosa, probably due to aberrancies in cell migration. Vagina is a rare site and primary melanoma of the vagina occurs in postmenopausal women with vaginal discharge, bleeding, or mass as common presenting complaints. Only a handful of case reports are available describing this entity on biopsy and PAP smear samples; however, fine needle aspiration has seldom been discussed. In the present report we discuss a case of an elderly female who complained of mass protruding through the vaginal opening, FNAC was done from the mass as well as from the right inguinal lymph node. An extensive clinicoradiological workup, and immunohistochemical confirmation is essential to rule out metastatic lesions and confirm primary. Diagn. Cytopathol. 2017;45:252-256. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis

    PubMed Central

    Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao

    2013-01-01

    AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631

  7. ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION IN THE DIAGNOSIS OF ADRENAL METASTASIS IN A HIGH-RISK POPULATION.

    PubMed

    Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina

    2017-12-01

    While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.

  8. A study of Galactin-3 on fine needle aspiration as a diagnostic marker differentiating benign from malignant thyroid neoplasm

    PubMed Central

    Muzafar, Alliya; Bukhari, Mulazim Hussain; Qureshi, Ihtesham uddin

    2017-01-01

    Background & Objective: Thyroid nodules are very common in our setup and their diagnosis on fine needle aspiration is not easy and is a taxing affair. It is a challenge to differentiate between follicular adenoma and follicular carcinoma without histology. Our objective was to investigate the role of Galectin-3 in fine needle aspirates of thyroid nodules as a prospective diagnostic marker and consequently its ability to differentiate benign from malignant neoplasms. Methods: The research was conducted at the department of Pathology, King Edward Medical University, in association with other teaching institutions of Lahore from June 2012 to July 2014.. Sixty cases of solitary thyroid nodules were included in the study. Haematoxylin and eosin staining of the fixed smears and Galectin-3 immunohistochemical staining of the sections prepared from the cell block was performed. Results: There were 60 patients in our study with a mean age of 33.35 years. The Bethesda system for reporting thyroid cytopathology was used to classify the smears and only categories IV, V and VI were included. On histological examination of the resected nodules there were 38.3% (23/60) cases of follicular adenoma, 46.6% (28/60) were of papillary carcinoma and follicular carcinoma made up to 15% (9/60) of all cases. Galectin-3 was negative in 100% (23/23) cases of follicular adenomas. Out of 37 malignant cases 65% lesions showed positivity, while 35% showed negativity for this immunomarker. Considering the malignant lesions, 75% cases of papillary carcinomas showed a positive reaction while only 33% of follicular carcinomas were positive for the immunomarker. This showed that the positive expression was more common in papillary as compared to follicular carcinomas. Conclusion: Galectin-3immunomarker is considerably expressed in malignant tumors, but it is not expressed in benign follicular lesions. PMID:28811803

  9. Thyroid Fine-Needle Aspiration Cytology:Causes of false-positive results.

    PubMed

    Malheiros, Daniela C; Canberk, Sule; Poller, David N; Schmitt, Fernando

    2018-05-16

    In this paper, we aim to focus on false positive results in the evaluation of thyroid aspirations, covering cystic, inflammatory, follicular and oncocytic lesions, papillary carcinoma, and medullary carcinoma of thyroid. The recently described entity, "noninvasive follicular thyroid neoplasm with papillary-like nuclear features" (NIFTP), is also discussed detailing the impact of its introduction on the sensitivity and specificity of thyroid FNA, as well as the use of molecular tests for diagnostics. Medicolegal issues in relation to current practice in English law are also described. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Application of special diagnostic techniques in the management of nodular goitre.

    PubMed Central

    Walfish, P. G.; Miskin, M.; Rosen, I. B.; Strawbridge, H. T.

    1976-01-01

    The primary challenge in the management of nodular goitre is to establish which thyroid nodules are malignant. Since selection of patients for operation on the basis of palpation of nodules alone gives a low yield of malignant disease, physicians have sought criteria for selection that combine the information obtained from special laboratory procedures with thoughtful clinical appraisal. Such special procedures, which include radioisotope scintiscanning, echography by B-mode ultrasonography, and either large- or fine-needle aspiration and cytologic examination of the aspirate, are considered valuable in a proposed clinical approach to the management of thyroid nodules. Images FIG. 1 FIG. 2 FIG. 3 PMID:1277058

  11. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    PubMed Central

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  12. Scarf pin-related hijab syndrome: A new name for an unusual type of foreign body aspiration

    PubMed Central

    Kakamad, Fahmi H.; Bakir, Delan Ahmed

    2017-01-01

    Background Foreign body aspiration refers to the inhalation of an object into the respiratory system and is a serious and potentially fatal event. A distinct group of patients has recently been recognized among Muslim nations. These patients include women who wear headscarves and place the safety pin in their mouth prior to securing the veils, leading to accidental foreign body aspiration. The aim of this study was to analyze the main presentation, diagnosis, treatment, and outcome of patients with scarf pin aspiration. Methods This prospective study involved patients with a history of scarf pin aspiration admitted to a single center during an 18-month period. Their main presentation, diagnosis, treatment, and outcome were analyzed. Results In total, 27 patients were included. The needle was extracted by flexible bronchoscopy in 12 (44.4%) patients, rigid bronchoscopy in 13 (48.1%), and thoracotomy in 2 (74%). One patient died during rigid bronchoscopy. All remaining 26 patients were satisfied with the postsurgical outcome at a mean follow-up of 1 week. Conclusions Scarf pin aspiration differs from other types of foreign body aspiration considering the specific population affected, and its management algorithm may thus differ from that of other foreign bodies. The left main bronchus is the most common site of pin impaction. Rigid bronchoscopy is the most commonly performed procedure for successful retrieval. PMID:28627978

  13. Scarf pin-related hijab syndrome: A new name for an unusual type of foreign body aspiration.

    PubMed

    Baram, Aram; Kakamad, Fahmi H; Bakir, Delan Ahmed

    2017-12-01

    Background Foreign body aspiration refers to the inhalation of an object into the respiratory system and is a serious and potentially fatal event. A distinct group of patients has recently been recognized among Muslim nations. These patients include women who wear headscarves and place the safety pin in their mouth prior to securing the veils, leading to accidental foreign body aspiration. The aim of this study was to analyze the main presentation, diagnosis, treatment, and outcome of patients with scarf pin aspiration. Methods This prospective study involved patients with a history of scarf pin aspiration admitted to a single center during an 18-month period. Their main presentation, diagnosis, treatment, and outcome were analyzed. Results In total, 27 patients were included. The needle was extracted by flexible bronchoscopy in 12 (44.4%) patients, rigid bronchoscopy in 13 (48.1%), and thoracotomy in 2 (74%). One patient died during rigid bronchoscopy. All remaining 26 patients were satisfied with the postsurgical outcome at a mean follow-up of 1 week. Conclusions Scarf pin aspiration differs from other types of foreign body aspiration considering the specific population affected, and its management algorithm may thus differ from that of other foreign bodies. The left main bronchus is the most common site of pin impaction. Rigid bronchoscopy is the most commonly performed procedure for successful retrieval.

  14. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses

    PubMed Central

    Voss, M; Hammel, P; Molas, G; Palazzo, L; Dancour, A; O'Toole, D; Terris, B; Degott, C; Bernades, P; Ruszniewski, P

    2000-01-01

    AIM—To assess the feasibility and diagnostic accuracy of endoscopic ultrasound guided fine needle biopsy (EUS-FNAB) in patients with solid pancreatic masses.
METHODS—Ninety nine consecutive patients with pancreatic masses were studied. Histological findings obtained by EUS-FNAB were compared with the final diagnosis assessed by surgery, biopsy of other tumour site or at postmortem examination, or by using a combination of clinical course, imaging features, and tumour markers.
RESULTS—EUS-FNAB was feasible in 90 patients (adenocarcinomas, n = 59; neuroendocrine tumours, n = 15; various neoplasms, n = 6; pancreatitis, n = 10), and analysable material was obtained in 73. Tumour size (⩾ or < 25 mm in diameter) did not influence the ability to obtain informative biopsy samples. Diagnostic accuracy was 74.4% (adenocarcinomas, 81.4%; neuroendocrine tumours, 46.7%; other lesions, 75%; p<0.02). Overall, the diagnostic yield in all 99 patients was 68%. Successful biopsies were performed in six patients with portal hypertension. Minor complications (moderate bleeding or pain) occurred in 5% of cases.
CONCLUSIONS—EUS-FNAB is a useful and safe method for the investigation of pancreatic masses, with a high feasibility rate even when lesions are small. Overall diagnostic accuracy of EUS-FNAB seems to depend on the tumour type.


Keywords: pancreas; tumour; endoscopic ultrasound; fine needle aspiration biopsy PMID:10644320

  15. Goitrous hypothyroidism associated with treatment with trimethoprim-sulfamethoxazole in a young dog.

    PubMed

    Seelig, Davis M; Whittemore, Jacqueline C; Lappin, Michael R; Myers, Alan M; Avery, Paul R

    2008-04-15

    A 16-week-old female Boxer that had been treated for 5 weeks with trimethoprim-sulfamethoxazole and chloramphenicol because of aspiration pneumonia was evaluated for bilaterally symmetric masses in the subcutaneous tissues of the ventral neck, in the region of the larynx. Fine-needle aspirates were obtained from the neck masses; cytologic examination revealed well-differentiated thyroid epithelial tissue. A blood sample was collected for serum biochemical and thyroid function analyses. Mild hyperphosphatemia, severe hypercholesterolemia, mild hyperkalemia, and a mild increase in creatine kinase activity were identified. Serum concentration of total thyroxine was less than the lower reference limit, and that of thyroid-stimulating hormone was greater than the upper reference limit. Findings were consistent with a diagnosis of clinical hypothyroidism in a skeletally immature dog. Treatment with trimethoprim-sulfamethoxazole was discontinued. The dog was reevaluated 3 weeks later, at which time the neck masses were markedly decreased in size. Serum concentrations of cholesterol and potassium were lower; serum concentrations of total thyroxine and thyroid-stimulating hormone were near or within respective reference ranges. Age-appropriate increases in serum phosphorus concentration and serum alkaline phosphatase activity were also detected. To the authors' knowledge, this is the first report of antimicrobial-induced goiter in a dog. Cytologic examination of fine-needle aspirates and interpretation of data from serum biochemical and thyroid function analyses were needed to obtain a definitive diagnosis. Practitioners should include goiter among the differential diagnoses for ventral neck swellings in young dogs receiving potentiated sulfonamide antimicrobials.

  16. Artificial neural network model to distinguish follicular adenoma from follicular carcinoma on fine needle aspiration of thyroid.

    PubMed

    Savala, Rajiv; Dey, Pranab; Gupta, Nalini

    2018-03-01

    To distinguish follicular adenoma (FA) and follicular carcinoma (FC) of thyroid in fine needle aspiration cytology (FNAC) is a challenging problem. In this article, we attempted to build an artificial neural network (ANN) model from the cytological and morphometric features of the FNAC smears of thyroid to distinguish FA from FC. The cytological features and morphometric analysis were done on the FNAC smears of histology proven cases of FA (26) and FC (31). The cytological features were analysed semi-quantitatively by two independent observers (RS and PD). These data were used to make an ANN model to differentiate FA versus FC on FNAC material. The performance of this ANN model was assessed by analysing the confusion matrix and receiving operator curve. There were 39 cases in training set, 9 cases each in validation and test sets. In the test group, ANN model successfully distinguished all cases (9/9) of FA and FC. The area under receiver operating curve was 1. The present ANN model is efficient to diagnose follicular adenoma and carcinoma cases on cytology smears without any error. In future, this ANN model will be able to diagnose follicular adenoma and carcinoma cases on thyroid aspirate. This study has immense potential in future. This is an open ended ANN model and more parameters and more cases can be included to make the model much stronger. © 2017 Wiley Periodicals, Inc.

  17. Fine-needle aspiration in desmoplastic small round cell tumor: a report of 10 new tumors in 8 patients with clinicopathological and molecular correlations with review of the literature.

    PubMed

    Klijanienko, Jerzy; Colin, Pierre; Couturier, Jérôme; Lagacé, Réal; Fréneaux, Paul; Pierron, Gaëlle; Laé, Marick; Klijanienko, Alice; Brisse, Hervé; Orbach, Daniel; Theocharis, Stamatios

    2014-05-01

    Desmoplastic small round cell tumor (DSRCT) is a rare round cell sarcoma entity characterized by a specific t(11;22)(p13;q12) translocation, usually intra-abdominal localization and an aggressive clinical outcome. To date, only 35 DSRCT cases diagnosed by fine-needle aspiration have been described. This study reports the cytological diagnosis of DSRCT. Ten tumors from 8 patients were sampled for diagnosis and analyzed to search the characteristic translocation using fluorescence in situ hybridization or reverse transcription polymerase chain reaction methods. Smears were always hypercellular and consisted of nonspecific round cell sarcoma. Nuclei were polymorphic round, kidney-, or heart-shaped. Nuclear molding was usually present. Paranuclear cytoplasmic densities were obvious and noted in 7 cases. Cytonuclear atypia, mitotic figures, numerous crushed nuclei, and apoptosis were frequently seen. Purple-stained stroma was present in 8 cases (ranging from few connective tissue fragments to large hyalinized deposits). Molecular studies based on cytological aspirates were performed in 8 patients. The presence of the fusion gene EWSR1-WT 1 transcript was identified in all, which confirmed the diagnosis of DSRCT. Smears showing poorly differentiated round cells associated with cytoplasmic densities and connective stoma, in a specific clinical context, young adult age, intra-abdominal localization, suggestive immunocytochemical profile, and a unique cytogenetic abnormality are highly specific and allow an accurate diagnosis of DSRCT. © 2014 American Cancer Society.

  18. Clinical usefulness of fine needle aspiration cytology in patients less than 20 years old: a 10-year experience at a single institution.

    PubMed

    Kim, Sunzoo; Jang, Eun Jeong; Jeong, Ji Yun; Park, Ji Young

    2013-01-01

    The purpose of this study was to identify the spectrum of cytological diagnoses and evaluate the diagnostic effectiveness of fine needle aspiration cytology (FNA) in patients less than 20 years old. The subjects were selected by retrospectively reviewing records from 1999 to 2009. Selected patients less than 20 years old underwent FNA. Cytological and histological slides of samples from the subjects were reviewed. Our study included a total of 909 subjects with a mean age of 14.6 years. The majority of the FNA samples were taken from lymph nodes (n = 448, 49.3%), with the remaining aspirates obtained from the thyroid gland (n = 247, 27.2%), soft tissues of head and neck masses (n = 106, 11.7%), salivary glands (n = 75, 8.3%), breasts (n = 18, 1.9%), skins (n = 9, 1.0%) and soft tissues of extremity (n = 6, 0.7%). The majority (87.6%, n = 796) of the FNA samples were categorized as 'benign', with the remaining designated as 'atypical lesion' (n = 18, 2.0%), 'malignant' (n = 24, 2.6%), or 'inadequate specimen' (n = 71, 7.8%). FNA accuracy was 92% for diagnosing cancer. Specificity and sensitivity were 99% and 63%, respectively. Our study first revealed that FNA has a high specificity for diagnosing cancer in various anatomical locations in young patients and can be confidently used as an effective tool for diagnosing malignancies in young individuals with a clinically suspicious lesion.

  19. Complications Following Radiofrequency Ablation of Benign Thyroid Nodules: A Systematic Review

    PubMed Central

    Wang, Jin-Fen; Wu, Tao; Hu, Kun-Peng; Xu, Wen; Zheng, Bo-Wen; Tong, Ge; Yao, Zhi-Cheng; Liu, Bo; Ren, Jie

    2017-01-01

    Objective: This systematic review examined whether radiofrequency ablation (RFA) is a safe treatment modality for benign thyroid nodules (BTNs). Data Sources: PubMed, Embase, and the Cochrane Library database were searched for articles that (a) targeted human beings and (b) had a study population with BTNs that were confirmed by fine-needle aspiration cytology and/or core needle biopsy. Study Selection: Thirty-two studies relating to 3409 patients were included in this systematic review. Results: Based on literatures, no deaths were associated with the procedure, serious complications were rare, and RFA appears to be a safe and well-tolerated treatment modality. However, a broad spectrum of complications offers insights into some undesirable complications, such as track needle seeding and Horner syndrome. Conclusions: RFA appears to be a safe and well-tolerated treatment modality for BTNs. More research is needed to characterize the complications of RFA for thyroid nodules. PMID:28524837

  20. Non-infected and Infected Bronchogenic Cyst: The Correlation of Image Findings with Cyst Content

    PubMed Central

    Jeon, Hong Gil; Park, Ju Hwan; Park, Hye Min; Kwon, Woon Jung; Cha, Hee Jeong; Lee, Young Jik; Park, Chang Ryul; Jegal, Yangjin; Ahn, Jong-Joon

    2014-01-01

    We hereby report a case on bronchogenic cyst which is initially non-infected, then becomes infected after bronchoscopic ultrasound (US)-guided transesophageal fine-needle aspiration (FNA). The non-infected bronchogenic cyst appears to be filled with relatively echogenic materials on US, and the aspirate is a whitish jelly-like fluid. Upon contrast-enhanced MRI of the infected bronchogenic cyst, a T1-weighted image shows low signal intensity and a T2-weighted image shows high signal intensity, with no enhancements of the cyst contents, but enhancements of the thickened cystic wall. The patient then undergo video-assisted thoracic surgery 14 days after the FNA. The cystic mass is known to be completely removed, and the aspirate is yellowish and purulent. To understand the image findings that pertain to the gross appearance of the cyst contents will help to diagnose bronchogenic cysts in the future. PMID:24624219

  1. Comparison of two different size needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing solid pancreatic lesions

    PubMed Central

    Xu, Mei-Mei; Jia, Hong-Yu; Yan, Li-Li; Li, Shan-Shan; Zheng, Yue

    2017-01-01

    Abstract Background: This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. Methods: We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. Results: Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%–95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%–91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65–28.14) and 0.16 (95% CI, 0.12–0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65–28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12–0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87–18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09–0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. Conclusion: Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS–FNA. PMID:28151856

  2. Intravascular flow detection during transforaminal epidural injections: a prospective assessment.

    PubMed

    El Abd, Omar Hamman; Amadera, Joao Eduardo Daud; Pimentel, Daniel Camargo; Pimentel, Thais Spacov Camargo

    2014-01-01

    Transforaminal epidural steroid injections (TFESI) are a mainstay in the treatment of spine pain. Though this commonly performed procedure is generally felt to be safe, devastating complications following inadvertent intra-arterial injections of particulate steroid have been reported. The use of digital subtraction angiography (DSA) has been suggested as a means of detecting intra-arterial needle placements prior to medication injection. To examine the efficacy of DSA in detecting intra-arterial needle placements during TFESI. Prospective cohort study evaluating the impact of DSA on detecting intra-arterial needle placements during TFESI. We enrolled 150 consecutive patients presenting to a university-affiliated spine center with discogenic and/or radicular symptoms affecting the cervical, lumbar, and sacral regions. For each injection, prior to imaging with DSA, traditional methods for vascular penetration detection were employed, including the identification of blood in the needle hub (flash), negative aspiration of blood prior to injection, and live fluoroscopic injection of contrast. Once these tests were performed and negative for signs of intra-arterial needle placement, DSA imaging was utilized prior to medication administration for identification of vascular flow. A total number of 222 TFESI were performed, 41 injections at the cervical levels (18.47%), 113 at the lumbar levels (50.9%), and 68 at the sacral levels (30.36%). Flash was observed in 13 injections performed (5.85% of the total number of injections): one (0.45%) in the cervical, 2 (0.9%) in the lumbar, and 10 (4.5%) in the sacral levels. In 11 TFESI blood aspiration was obtained (4.95% of all injections): 3 (1.3%) in cervical, 4 (1.8%) in lumbar, and 4 (1.8%) in sacral injections. Live fluoroscopy during contrast injection detected 46 (20.72%) intravascular flow patterns: 7 (3.1%) cervical, 17 (7.6%) lumbar, and 22 (9.9%) sacral. DSA identified an additional 5 intravascular injections after all previous steps had resulted in negative vascular penetration signs, which accounted for 2.25% of all injections. This is a prospective, single-center study with a relatively small number of patients and no control group. DSA detected additional 5.26% intravascular needle placements following traditional methods. Our findings also support other studies that conclude TFESI are generally a safe procedure. We recommend that special attention should be paid to the sacral injections as vascular penetration was statistically higher than at other levels.

  3. Conference Support - Surgery in Extreme Environments - Center for Surgical Innovation

    DTIC Science & Technology

    2007-01-01

    flights. During this 16-day mission in April 1998, surgical procedures, including thoracotomies, laparotomies, craniotomies , laminectomies, and...fixation, craniotomy , laminectomy, and leg dissection. These experiments also permitted the evaluation of IV insertion using the autonomic protocol and...missions will be required to address: Repair of lacerations; wound cement, layered closure Incision and drainage of abscess Needle aspiration of

  4. Infection

    DTIC Science & Technology

    2010-09-01

    promote host tissue attachment and prevent sepsis represent new areas of scientific inquiry. Novel Ways to Detect Infection Swabs, needle aspiration, deep...chromosome, the bacteria emits light at 486-nm wavelength during normal bacteria respiration, and the amount of photons emitted is determined by the amount of...within 5 hours.3 Bacterial or fungal DNA is amplified by polymerase chain reaction and introduced into a mass spectroscopy by electrospray ionization

  5. Intrauterine transfusion with the use of phased array ultrasonography: a new technique.

    PubMed

    Frigoletto, F D; Birnholz, J C; Rothchild, S B; Finberg, H J; Umansky, I

    1978-06-01

    Continuous ultrasonic observation of needle placement for aspiration, biopsy, or catheter placement is a novel and specific use of phased array imaging. In the case of IUTx, catheter placement into the fetal peritoneal space is accomplished rapidly, with reduced risk of fetal trauma, and without exposure to ionizing radiation. Experience with 27 transfusions in 11 patients is presented.

  6. Thyroid cancer: what to do after fine needle aspiration.

    PubMed

    Rometo, David A; Baranski, Thomas J

    2011-01-01

    The incidence of differentiated thyroid cancer (including papillary, follicular, and Hurthle cell carcinoma) has nearly tripled in the past 20 years. Diagnosis, treatment, and long-term management are evolving with advances in radiology, surgical techniques, nuclear medicine, genetics, and targeted therapeutics. Here we detail the current recommended course of action for differentiated thyroid cancer and options on the horizon.

  7. [Value of aspiration biopsy of subcutaneous fat in amyloidosis].

    PubMed

    Ponce, P; Carvalho, F; Coelho, A

    1986-01-01

    Fine-needle aspiration of subcutaneous fat (FNAF) was performed in 24 patients, 12 with previously diagnosed amyloidosis presenting with proteinuria or nephrotic syndrome, and 12 presenting a nephrotic syndrome without amyloidosis on renal biopsy. FNAF was positive in 10 of 12 patients with amyloidosis (sensitivity: 83%) and negative in 12 of 12 patients with non-amyloid nephrotic syndrome (specificity: 100%). Considering a 2.5 to 10% prevalence of amyloidosis in adult patients with proteinuria or nephrotic syndrome, a positive FNAF is diagnostic of amyloidosis, and a negative FNAF rules out the diagnosis with a probability of 98 to 99%. FNAF is a simple and safe method which can be useful in patients who cannot undergo a renal biopsy.

  8. Filarial abscess: Aspiration of adult gravid female worm from submandibular region, an unusual presentation.

    PubMed

    Afrose, Ruquiya; Alam, Mohammad Feroz; Ahmad, Syed Shamshad; Naim, Mohammed

    2017-01-01

    Microfilaria is a major public health problem in tropical and subtropical countries and is an endemic problem in India. Wuchereria bancrofti is the most common filarial infection. In some cases, microfilariae and adult filarial worm have been incidentally detected in fine-needle aspirates of various lesions; detection of microfilaria from subcutaneous site or from abscess site is even rarer. We here report an unusual case of Bancroftian microfilariasis in a 68-year-old female coming from endemic area presenting with right submandibular abscess. Our aim is to highlight the chances of finding microfilaria and adult worm in cytology of an unsuspected case at an unusual site.

  9. Filarial abscess: Aspiration of adult gravid female worm from submandibular region, an unusual presentation

    PubMed Central

    Afrose, Ruquiya; Alam, Mohammad Feroz; Ahmad, Syed Shamshad; Naim, Mohammed

    2017-01-01

    Microfilaria is a major public health problem in tropical and subtropical countries and is an endemic problem in India. Wuchereria bancrofti is the most common filarial infection. In some cases, microfilariae and adult filarial worm have been incidentally detected in fine-needle aspirates of various lesions; detection of microfilaria from subcutaneous site or from abscess site is even rarer. We here report an unusual case of Bancroftian microfilariasis in a 68-year-old female coming from endemic area presenting with right submandibular abscess. Our aim is to highlight the chances of finding microfilaria and adult worm in cytology of an unsuspected case at an unusual site. PMID:28182103

  10. Diagnosis of Infectious Diseases: a Cytopathologist’s Perspective

    PubMed Central

    Powers, Celeste N.

    1998-01-01

    This review explores the role of the cytopathology laboratory in the detection and presumptive identification of microorganisms. Sample procurement by exfoliation, abrasion, and aspiration techniques, as well as a variety of cytopreparatory and staining methods, is reviewed. Emphasis is placed on the utility of fine-needle aspiration as a rapid, safe, and cost-effective diagnositic procedure. The role of rapid interpretation and specimen triage is also discussed. Cytomorphologic features and staining characteristics are presented for a spectrum of microorganisms potentially encountered in the cytopathology laboratory. Pitfalls in diagnosis and the usefulness of special stains and ancillary techniques are also evaluated. The importance of communication, collaboration, and clinical correlation is stressed. PMID:9564567

  11. 3D-ultrasound in imaging, diagnosis and follow-up of an atypical hydatid cyst.

    PubMed

    Ockenga, J; Gebel, M; Caselitz, M; Topalidis, T; Boozari, B; Bleck, J; Manns, M P

    1998-07-01

    Abdominal ultrasonography is the procedure of choice to diagnose hydatid cysts caused by Echinococcus granulosus. Recently three-dimensional ultrasonography has become available for clinical application. We report a case of an atypical seronegative hydatid disease, in which the additional use of 3D-sonography improved the sonographic diagnosis, which was confirmed by a fine needle biopsie complicated by an anaphylactic reaction. In addition the potential advantage of 3D-ultrasonography in diagnosis and follow-up hydatid disease will be discussed, especially in the context of new alternative therapeutic options like chemotherapy with benzimidazoles or the percutaneous drainage by the PAIR procedure (puncture-aspiration-injection-re-aspiration).

  12. Pulmonary metastases of recurrent intracranial hemangiopericytoma diagnosed on fine needle aspiration cytology: a case report.

    PubMed

    Goel, Deepa; Babu, Sasidhara; Prayaga, Aruna K; Sundaram, Challa

    2008-01-01

    Meningeal hemangiopericytoma (HPC) is a rare neoplasm. It is closely related to hemangiopericytomas in systemic tissues, with a tendency to recur and metastasize outside the CNS. Only a few case reports describe the cytomorphologic appearance of these metastasizing lesions, most having primary tumor in deep soft tissues. We report a case of recurrent meningeal HPC metastasizing to lungs. A 48-year-old woman presented with a history of headache. She underwent primary surgery 10 years previously for left parietal tumor. Histopathologic diagnosis was HPC. Radiotherapy was given postoperatively. Brain magnetic resonance imaging (MRI) at admission suggested local recurrence. She also complained of dry cough and shortness of breath. On evaluation, computed tomography (CT) scan lung showed multiple, bilateral, small nodules. Fine needle aspiration cytology (FNAC) of a larger nodule revealed spindle-shaped cells arranged around blood vessels. Immunohistochemistry with CD34 on cell block confirmed metastatic HPC. FNAC is an easy, accurate, relatively noninvasive procedure for diagnosing metastases, especially in patients with a history of recurrent intracranial HPC. Immunohistochemistry on cell block material collected at the time of FNAC may aid in distinguishing HPC from other tumors that are close mimics cytologically.

  13. Point of care assessment of melanoma tumor signaling and metastatic burden from μNMR analysis of tumor fine needle aspirates and peripheral blood.

    PubMed

    Gee, Michael S; Ghazani, Arezou A; Haq, Rizwan; Wargo, Jennifer A; Sebas, Matthew; Sullivan, Ryan J; Lee, Hakho; Weissleder, Ralph

    2017-04-01

    This study evaluates μNMR technology for molecular profiling of tumor fine needle aspirates and peripheral blood of melanoma patients. In vitro assessment of melanocyte (MART-1, HMB45) and MAP kinase signaling (pERK, pS6K) molecule expression was performed in human cell lines, while clinical validation was performed in an IRB-approved study of melanoma patients undergoing biopsy and blood sampling. Tumor FNA and blood specimens were compared with BRAF genetic analysis and cross-sectional imaging. μNMR in vitro analysis showed increased expression of melanocyte markers in melanoma cells as well as increased expression of phosphorylated MAP kinase targets in BRAF-mutant melanoma cells. Melanoma patient FNA samples showed increased pERK and pS6K levels in BRAF mutant compared with BRAF WT melanomas, with μNMR blood circulating tumor cell level increased with higher metastatic burden visible on imaging. These results indicate that μNMR technology provides minimally invasive point-of-care evaluation of tumor signaling and metastatic burden in melanoma patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The reliability of fine-needle aspiration biopsy in terms of malignancy in patients with Hashimoto thyroiditis.

    PubMed

    Kapan, Murat; Onder, Akin; Girgin, Sadullah; Ulger, Burak Veli; Firat, Ugur; Uslukaya, Omer; Oguz, Abdullah

    2015-02-01

    The aim of this study was to analyze the presence of malignancy in patients with Hashimoto's thyroiditis and to investigate the reliability of preoperative fine-needle aspiration biopsy (FNAB). The retrospective study included 44 patients who were operated on for nodular goiter between December 2010 and October 2011. The patients underwent thyroidectomy following a cytologic analysis plus FNAB. Hashimoto's thyroiditis was confirmed on histopathology in all patients. FNAB results were defined as benign in 14 (31.8%), suspicion for malignancy in 17 (38.6%), malignant in 9 (20.5%), and inadequate in 4 (9.1%). Following the thyroidectomy, presence of papillary thyroid carcinoma and follicular variant of papillary thyroid carcinoma were detected in 10 patients (22.7%) and 1 (2.3%) patient, respectively. The FNAB results were interpreted in terms of malignancy, which revealed the sensitivity as 80%; specificity, 40%; false positives, 69.2%; false negatives, 14.3%; positive predictive value, 31.8%; negative predictive value, 85.7%; and diagnostic accuracy, 50%. The coexistence of Hashimoto's thyroiditis with papillary thyroid carcinoma is quite common. The FNAB results for such cases are hard to evaluate, and they are likely to increase the number of false positives.

  15. Diagnosis of metastatic pancreatic mesenchymal tumors by endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Varghese, Linda; Ngae, Min Yi; Wilson, Andrew P; Crowder, Clinton D; Gulbahce, H Evin; Pambuccian, Stefan E

    2009-11-01

    Involvement of the pancreas by metastatic sarcoma is rare, and can prove challenging to differentiate from sarcomatoid carcinomas which occur more commonly. The endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) technique has been successfully used for the diagnosis of pancreatic carcinomas whether primary or metastatic, and is now considered the most effective noninvasive method for the identification of pancreatic metastases. However, to date very few reports detail the diagnosis of mesenchymal neoplasms by EUS-FNA. Herein, we report a series of four patients who underwent EUS-FNA of the pancreas, where the diagnosis of metastatic sarcoma was made based on morphology and ancillary studies. The cases include metastases of leiomyosarcoma, liposarcoma, alveolar rhabdomyosarcoma, and solitary fibrous tumor. The history of a primary sarcoma of the chest wall, mediastinum, and respectively lower extremity was known for the first three of these patients while in the case of the solitary fibrous tumor a remote history of a paraspinal "hemangiopericytoma" was only elicited after the EUS-FNA diagnosis was made. We conclude that EUS-FNA is efficient and accurate in providing a diagnosis of sarcoma, even in patients without a known primary sarcoma, thus allowing institution of therapy without additional biopsies.

  16. Extraneural metastases of primary central nervous system tumors identified by fine needle aspiration: a retrospective analysis.

    PubMed

    Vandenbussche, Christopher J; Ho, Cheng-Ying; Nugent, Summer L; Ali, Syed Z

    2014-01-01

    Extraneural metastasis (EM) of primary central nervous system (PCNS) neoplasms is rare and signifies a poor clinical outcome. Due to its infrequent occurrence, relatively few reports on the cytomorphology of these neoplasms have been published. We describe a series of 19 cases from 16 patients at a single, large tertiary care center. A retrospective analysis of 19 cases of metastases from PCNS neoplasms identified on fine needle aspiration (FNA) in 8 male and 8 female patients aged 14-72 years (mean age 39.6) from 1989 to 2013 was conducted to further characterize the cytomorphologic features identified at metastatic sites. Six different PCNS neoplasms were identified: meningioma, glioblastoma, hemangiopericytoma (HPC), oligodendroglioma, medulloblastoma, and retinoblastoma. The mean latency period between the diagnoses of the primary and first metastatic tumors was 7.4 years (range 0-15). The most common PCNS malignancy responsible for EM was HPC. The most common metastatic sites were the lung (31%) and soft tissue/bone (31%). EM of PCNS tumors is extremely rare. FNA allows for quick, safe and accurate diagnosis. Cytomorphologic features are characteristic, and in conjunction with the clinical history and immunohistochemistry, an accurate diagnosis was obtained in 100% of the cases.

  17. Cytological diagnostic of lymphadenitis tuberculosis by eosinophilic material

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Kusumawati, L.

    2018-03-01

    AFB sputum and chest X-ray are used to identify patients with pulmonary TB. For extrapulmonary TB, fine needle aspiration cytology is needed, even though occasionally found not atypical feature in the form of eosinophilic material with dark brown particles, suspected as TB. This research was to show that eosinophilic material with dark brown particles is accurate as new criteria for the cytological diagnosis of TB. By performing fine needle aspiration biopsy stained with Giemsa, if an eosinophilic material with dark brown particles was encountered, we continued with Ziehl-Neelsen AFB stain and confirmed with PCR. To assess accuracy, we used a diagnostic test to evaluate sensitivity and specificity of eosinophilic material with dark brown particles by using AFB and PCR as the gold standard. The sensitivity and specificity of cytological diagnosis in tuberculosis of eosinophilic material with dark brown particles were 93.65% and 70.99%, respectively if confirmed with AFB. On the other hand, if confirmed with PCR using Mycobacterium tuberculosis DNA, the sensitivity and specificity were 98.95% and 96.79%, respectively. In conclusion, eosinophilic masses with dark brown particles is accurate as new criteria of TB diagnostic cytology with high sensitivity and specificity confirmed with AFB and PCR test.

  18. Influence of thyroid gland status on the thyroglobulin cutoff level in washout fluid from cervical lymph nodes of patients with recurrent/metastatic papillary thyroid cancer.

    PubMed

    Lee, Jun Ho; Lee, Hyun Chul; Yi, Ha Woo; Kim, Bong Kyun; Bae, Soo Youn; Lee, Se Kyung; Choe, Jun-Ho; Kim, Jung-Han; Kim, Jee Soo

    2016-04-01

    The influence of serum thyroglobulin (Tg) and thyroidectomy status on Tg in fine-needle aspiration cytology (FNAC) washout fluid is unclear. A total of 282 lymph nodes were prospectively subjected to FNAC, fine-needle aspiration (FNA)-Tg measurement, and frozen and permanent biopsies. We evaluated the diagnostic performance of several predetermined FNA-Tg cutoff values for recurrence/metastasis in lymph nodes according to thyroidectomy status. The diagnostic performance of FNA-Tg varied according to thyroidectomy status. The optimized cutoff value of FNA-Tg was 2.2 ng/mL. However, among FNAC-negative lymph nodes, the FNA-Tg cutoff value of 0.9 ng/mL showed better diagnostic performance in patients with a thyroid gland. An FNA-Tg/serum-Tg cutoff ratio of 1 showed the best diagnostic performance in patients without a thyroid gland. Applying the optimal cutoff values of FNA-Tg according to thyroid gland status and serum Tg level facilitates the diagnostic evaluation of neck lymph node recurrences/metastases in patients with papillary thyroid carcinoma (PTC). © 2015 Wiley Periodicals, Inc. Head Neck 38: E1705-E1712, 2016. © 2015 Wiley Periodicals, Inc.

  19. Lymphoepithelial cyst of the pancreas: an analysis of 117 patients.

    PubMed

    Mege, Diane; Grégoire, Emilie; Barbier, Louise; Del Grande, Jean; Le Treut, Yves Patrice

    2014-10-01

    Lymphoepithelial cyst (LEC) of the pancreas is an unusual and benign cystic tumor. Accurate preoperative diagnosis is difficult; hence, most of pancreatic LECs are resected. The aim was to describe clinicopathological features of pancreatic LEC to guide appropriate management. We retrospectively collected data about LEC patients treated in our department between 1987 and 2012 and added cases from review of the literature during the same period. One hundred seventeen cases (3 from our institution and 114 from literature review) were identified. Most patients were men (78%). The discovery was generally fortuitous. Serum CA19-9 was elevated in half of the cases. No specific radiological feature was identified. Fine needle aspiration and cytologic analysis allowed a correct preoperative diagnosis in 21% of the patients, showing presence of squamous cells, lymphocytes, and keratinous debris. Half of them were treated conservatively, whereas other patients underwent surgery. Neither malignant transformation nor recurrence after resection was observed. The LEC of the pancreas is a rare benign tumor that could be treated conservatively. Fine needle aspiration is the only tool that can achieve a diagnosis without resection. If no certain diagnosis can be made, surgery is warranted to rule out a malignant differential diagnosis.

  20. Split sample comparison of a liquid-based method and conventional smears in thyroid fine needle aspiration.

    PubMed

    Jung, Chan-Kwon; Lee, Ahwon; Jung, Eun-Sun; Choi, Yeong-Jin; Jung, So-Lyung; Lee, Kyo-Young

    2008-01-01

    To compare the efficacy of the SurePath (SP) vs. conventional smears (CS) in fine needle aspiration (FNA) of thyroid gland lesions. A total of 193 FNA cases with thyroid nodules were studied. Samples from ultrasound-guided FNA were split to prepare CS and SP slides. The diagnostic categories of unsatisfactory, benign, atypical and malignant were compared. Galectin-3 immunostaining was performed on SP slides. Some differences were found between the cytomorphology of CS and SP. SP slides showed more increased cellularity and more clustered tissue fragments. On SP slides, nuclear detail and nucleoli were more easily detected and nuclear irregularity was very useful for the diagnosis of papillary carcinoma. SP showed a trend toward a lower proportion of atypical category. The overall sensitivity of FNA in diagnosing thyroid neoplasm was 90.9% for CS and 93.9% for SP. Most lesions (73%) diagnosed as papillary carcinoma after surgery showed positive staining of galectin-3. The SP method showed easy evaluation of cytomorphologic features and consistent specimen quality and appeared to be more useful in diagnosing the suspicious cases. Moreover, it offered the possibility of adjunctive immunocytochemistry on the same sample.

  1. Fine-needle aspiration of a Xp11.2 translocation/TFE3 fusion renal cell carcinoma metastatic to the lung: report of a case and review of the literature.

    PubMed

    Schinstine, Malcolm; Filie, Armando C; Torres-Cabala, Carlos; Abati, Andrea; Linehan, W Marston; Merino, Maria

    2006-11-01

    A 57-yr-old woman presented to the National Cancer Institute (NCI) with a history of nephrectomy for a clear cell renal cell carcinoma (RCC), Fuhrman grade 3 of 4 diagnosed 1 yr prior to admission to the NCI. A CT scan done upon admission revealed multiple bilateral lung masses. A CT-guided fine-needle aspiration (FNA) of one of the lung masses revealed a cellular specimen composed primarily of follicular structures surrounding dense hyalinized central cores. The cells in the follicular structures displayed bland nuclei and had granular to vacuolated cytoplasm. Papillary structures were also appreciated. Immunocytochemical studies showed tumor cells that were strongly vimentin and TFE3 positive. Focal staining for AE1/AE3 and CD10 was observed, as was negative staining for EMA. A surgical biopsy specimen reflected the FNA findings and demonstrated a similar immunoprofile. These findings correspond to the recently described Xp11.2 translocation/TFE3 fusion renal cell carcinoma. To our knowledge, this is the first report describing the cytologic features of an Xp11.2 translocation/TFE3 fusion RCC. (C) 2006 Wiley-Liss, Inc.

  2. [Enterococcus faecium lung abscess: one case report and literature review].

    PubMed

    Fang, Xiang-Qun; Liu, You-Ning

    2010-02-01

    to study the diagnosis and treatment of enterococcus faecium lung abscess. a retrospective analysis of one case of Enterococcus faecium lung abscess and literature review was conducted. this patient suffered from cough and sputum over 6 months and complicated with hemoptysis over 3 months. Pulmonary embolism and lung cancer were suspected initially. After 2 times of CT-guided percutaneous transthoracic needle aspiration biopsy the diagnosis of pneumonia was made in other hospitals. However, the consolidation in the lung progressed and cavity appeared although antibiotic therapy was conducted. After admission to our hospital, CT-guided percutaneous transthoracic needle aspiration biopsy was made and the lung tissue was sent for bacterial culture. Enterococcus faecium was cultured and it was susceptible to vancomycin, teicoplanin and linezolid. The disease improved significantly after treatment with these 3 antibiotics in turn. In addition, 13 cases of enterococcus pneumonia or lung abscess were reviewed, including 3 cases of enterococcus faecium lung abscess. enterococcus faecium is rarely a pathogen for lung abscess. The diagnosis of enterococcus faecium lung abscess could be confirmed by lung biopsy and bacterial culture of lung tissue which could also provide the susceptibility of antibiotics and guide the antibiotic therapy.

  3. Solitary thyroid metastasis from colon cancer: fine-needle aspiration cytology and molecular biology approach.

    PubMed

    Onorati, M; Uboldi, P; Bianchi, C L; Nicola, M; Corradini, G M; Veronese, S; Fascì, A I; Di Nuovo, F

    2015-01-01

    Thyroid gland is one of the most vascularized organs of the body, nevertheless clinical and surgical series report an incidence of secondary malignancies in this gland of only 3%. Colorectal carcinoma metastatic to the thyroid gland is not as uncommon as previously believed, infact the number of cases seems to be increased in recent years due to the more frequent use of fine-needle aspiration cytology (FNAC) guided by ultrasonography. Although kidney, breast and lung metastases to the thyroid are frequent, metastasis from colon cancer is clinically rare with 52 cases reported in the literature in the last 5 decades and three cases described as solitary thyroid metastasis from the colon cancer without any other visceral metastases. To the best of our knowledge, we report the fourth case of solitary, asymptomatic thyroid metastasis from colon cancer without involvement of other organs. We discuss the importance of FNAC to detect metastatazing process as a compulsory step of the diagnostic and therapeutic management algorithm, combined with a molecular biology approach. A review of the last 5 decades literature, to update the number of cases described to date, is also included.

  4. A Clinicopathological Analysis of Soft Tissue Sarcoma with Telangiectatic Changes.

    PubMed

    Kobayashi, Hiroshi; Ae, Keisuke; Tanizawa, Taisuke; Gokita, Tabu; Motoi, Noriko; Matsumoto, Seiichi

    2015-01-01

    Background. Soft tissue sarcoma with a hemorrhagic component that cannot be easily diagnosed by needle biopsy is defined here as soft tissue sarcoma with telangiectatic changes (STST). Methods. We retrospectively reviewed clinicopathological data of STST from 14 out of 784 patients (prevalence: 1.8%) with soft tissue sarcoma. Results. Tumors were found mostly in the lower leg. Histological diagnoses were undifferentiated pleomorphic sarcoma (n = 5), synovial sarcoma (n = 5), epithelioid sarcoma (n = 2), and malignant peripheral nerve sheath tumor and fibrosarcoma (n = 1). No history of trauma to the tumor site was recorded in any patient. Needle aspiration transiently reduced the tumor volume, but subsequent recovery of tumor size was observed in all cases. Out of 14 patients, 9 presented with a painful mass. MRI characteristics included intratumoral nodules (64.3%). The local recurrence rate was 14.3%, and the 2-year event-free survival rate was poorer (50%) than that of most sarcomas. Conclusions. STST is unique in its clinicopathological presentation. Painful hematomas without a trauma history, intratumoral nodules within a large hemorrhagic component, and subsequent recovery of tumor size after aspiration are indicative of the presence of STST.

  5. A Clinicopathological Analysis of Soft Tissue Sarcoma with Telangiectatic Changes

    PubMed Central

    Kobayashi, Hiroshi; Ae, Keisuke; Tanizawa, Taisuke; Gokita, Tabu; Motoi, Noriko; Matsumoto, Seiichi

    2015-01-01

    Background. Soft tissue sarcoma with a hemorrhagic component that cannot be easily diagnosed by needle biopsy is defined here as soft tissue sarcoma with telangiectatic changes (STST). Methods. We retrospectively reviewed clinicopathological data of STST from 14 out of 784 patients (prevalence: 1.8%) with soft tissue sarcoma. Results. Tumors were found mostly in the lower leg. Histological diagnoses were undifferentiated pleomorphic sarcoma (n = 5), synovial sarcoma (n = 5), epithelioid sarcoma (n = 2), and malignant peripheral nerve sheath tumor and fibrosarcoma (n = 1). No history of trauma to the tumor site was recorded in any patient. Needle aspiration transiently reduced the tumor volume, but subsequent recovery of tumor size was observed in all cases. Out of 14 patients, 9 presented with a painful mass. MRI characteristics included intratumoral nodules (64.3%). The local recurrence rate was 14.3%, and the 2-year event-free survival rate was poorer (50%) than that of most sarcomas. Conclusions. STST is unique in its clinicopathological presentation. Painful hematomas without a trauma history, intratumoral nodules within a large hemorrhagic component, and subsequent recovery of tumor size after aspiration are indicative of the presence of STST. PMID:26839509

  6. Papanicolaou Society of Cytopathology new guidelines have a greater ability of risk stratification for pancreatic endoscopic ultrasound-guided fine-needle aspiration specimens

    PubMed Central

    Chen, Bo; Zhao, Yu; Gu, Jiangang; Wu, Huanwen; Liang, Zhiyong; Meng, Zhilan

    2017-01-01

    The Papanicolaou Society of Cytopathology has recently proposed a standardized terminology and nomenclature guidelines for pancreatic cytology. However the risk of malignancy associated with the new guidelines has been scarcely studied. In this study, a series of pancreatic cytology cases obtained by endoscopic ultrasound-guided fine-needle aspiration from 294 Chinese patients were retrospectively re-categorized into six categories according the new guidelines. The risks of malignancy were 18.1% for “negative,” 20.0% for “neoplastic,” 57.1% for “nondiagnostic,” 69.2% for “atypical,” 87.5% for “suspicious,” and 100.0% for “positive” respectively. The area under the receiver operating characteristic curve was 0.93 (95% Confidence Interval, 0.90-0.96), which was significantly higher than that associated with old classification system (0.82; 95% Confidence Interval, 0.77-0.87) conventionally used in China. Our investigation demonstrated that the new guidelines have a greater ability of risk stratification than the old classification system conventionally used in China. This may be helpful in giving better predictions of malignancy, thus leading to more personalized treatment strategies. PMID:28042957

  7. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    PubMed

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. A Rare and Severe Complication Following Thyroid Fine Needle Aspiration: Retropharyngeal Cellulitis

    PubMed Central

    Cesareo, Roberto; Naciu, Anda; Barberi, Antonio; Pasqualini, Valerio; Pelle, Giuseppe; Manfrini, Silvia; Tabacco, Gaia; Pantano, Angelo Lauria; Campagna, Giuseppe; Cianni, Roberto; Palermo, Andrea

    2016-01-01

    Introduction Fine needle aspiration (FNA) is the most accurate and cost-effective method for evaluating thyroid nodules. We have reported a rare complication related to the procedure: severe retropharyngeal cellulitis. Case Presentation A thirty-five-year-old female was admitted to hospital with hoarseness, laryngeal stridor and dyspnea without fever that emerged about 3 days after a first diagnostic FNA. After the procedure, the patient felt her voice became hoarse and 1 day before presentation began to have dyspnea, without fever. It had become difficult for her to swallow solids, and she felt as if food was sticking in her throat. In the emergency room, hematochemical tests and CT scan of the neck/mediastinum had been performed. This showed leukocytosis with neutrophilia and a severe cellulitis framework with involvement of the laterocervical neck area and in particular, the invasion of the retropharynx and the upper part of the mediastinum. The patient was admitted in hospital for an anti-inflammatory therapy with cortisone and antibiotic therapy. Conclusions For the first time to our knowledge, we have reported a severe retropharyngeal and upper mediastinum cellulitis, probably due to the FNA procedure in an immunocompetent young woman. PMID:28123438

  9. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics.

    PubMed

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J; Sobrinho Simoes, Manuel

    2017-07-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF , NRAS , HRAS , KRAS , PAX8/PPARG , RET/PTC ) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation.

  10. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics

    PubMed Central

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J.; Sobrinho Simoes, Manuel

    2017-01-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF, NRAS, HRAS, KRAS, PAX8/PPARG, RET/PTC) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation. PMID:28785538

  11. GeneXpert MTB/RIF Assay for the Diagnosis of Tuberculous Lymphadenitis on Concentrated Fine Needle Aspirates in High Tuberculosis Burden Settings.

    PubMed

    Tadesse, Mulualem; Abebe, Gemeda; Abdissa, Ketema; Aragaw, Dossegnaw; Abdella, Kedir; Bekele, Alemayehu; Bezabih, Mesele; Apers, Ludwig; de Jong, Bouke C; Rigouts, Leen

    2015-01-01

    The diagnosis of tuberculous lymphadenitis (TBL) remains challenging. The routinely used methods (cytology and smear microscopy) have sub-optimal sensitivity. Recently, WHO recommends GeneXpert to be used as the initial diagnostic test in patients suspected of having extra-pulmonary tuberculosis (EPTB). However, this was a conditional recommendation due to very low-quality evidence available and more studies are needed. In this study we evaluated the performance of Xpert for the diagnosis of TBL on concentrated fine needle aspirates (FNA) in Southwest Ethiopia. FNA was collected from presumptive TBL cases. Two smears were prepared from each aspirate and processed for cytology and conventional microscopy. The remaining aspirate was treated with N-acetyl-L-cysteine-NaOH and centrifuged for 15minutes at 3000g. The concentrated sediment was used for culture and Xpert test. Capilia TB-Neo test was used to differentiate M. tuberculosis complex (MTBC) from non-tuberculous mycobacteria (NTM). Composite bacteriological methods (culture and/or smear microscopy) were considered as a reference standard. Out of 143 enrolled suspects, 64.3% (92/143) were confirmed TBL cases by the composite reference standard (CRS). Xpert detected M. tuberculosis complex (MTBC) in 60.1% (86/143) of the presumptive TBL cases. The sensitivity of Xpert compared to CRS was 87.8% [95% CI: 81.0-94.5] and specificity 91.1% [95% CI: 82.8-99.4]. The sensitivity was 27.8% for smear microscopy and 80% for cytology compared to CRS. Cytology showed the lowest specificity (57.8%). Xpert was positive in 4 out of 45 culture- and smear-negative cases. Among 47 cytomorphologically non-TBL cases, 15 were positive on Xpert. More than half of Xpert-positive cases were in the range of very low cut-off threshold values (28

  12. Development and evaluation of needle trap device geometry and packing methods for automated and manual analysis.

    PubMed

    Warren, Jamie M; Pawliszyn, Janusz

    2011-12-16

    For air/headspace analysis, needle trap devices (NTDs) are applicable for sampling a wide range of volatiles such as benzene, alkanes, and semi-volatile particulate bound compounds such as pyrene. This paper describes a new NTD that is simpler to produce and improves performance relative to previous NTD designs. A NTD utilizing a side-hole needle used a modified tip, which removed the need to use epoxy glue to hold sorbent particles inside the NTD. This design also improved the seal between the NTD and narrow neck liner of the GC injector; therefore, improving the desorption efficiency. A new packing method has been developed and evaluated using solvent to pack the device, and is compared to NTDs prepared using the previous vacuum aspiration method. The slurry packing method reduced preparation time and improved reproducibility between NTDs. To evaluate the NTDs, automated headspace extraction was completed using benzene, toluene, ethylbenzene, p-xylene (BTEX), anthracene, and pyrene (PAH). NTD geometries evaluated include: blunt tip with side-hole needle, tapered tip with side-hole needle, slider tip with side-hole, dome tapered tip with side-hole and blunt with no side-hole needle (expanded desorptive flow). Results demonstrate that the tapered and slider tip NTDs performed with improved desorption efficiency. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. An investigation into false-negative transthoracic fine needle aspiration and core biopsy specimens.

    PubMed

    Minot, Douglas M; Gilman, Elizabeth A; Aubry, Marie-Christine; Voss, Jesse S; Van Epps, Sarah G; Tuve, Delores J; Sciallis, Andrew P; Henry, Michael R; Salomao, Diva R; Lee, Peter; Carlson, Stephanie K; Clayton, Amy C

    2014-12-01

    Transthoracic fine needle aspiration (TFNA)/core needle biopsy (CNB) under computed tomography (CT) guidance has proved useful in the assessment of pulmonary nodules. We sought to determine the TFNA false-negative (FN) rate at our institution and identify potential causes of FN diagnoses. Medical records were reviewed from 1,043 consecutive patients who underwent CT-guided TFNA with or without CNB of lung nodules over a 5-year time period (2003-2007). Thirty-seven FN cases of "negative" TFNA/CNB with malignant outcome were identified with 36 cases available for review, of which 35 had a corresponding CNB. Cases were reviewed independently (blinded to original diagnosis) by three pathologists with 15 age- and sex-matched positive and negative controls. Diagnosis (i.e., nondiagnostic, negative or positive for malignancy, atypical or suspicious) and qualitative assessments were recorded. Consensus diagnosis was suspicious or positive in 10 (28%) of 36 TFNA cases and suspicious in 1 (3%) of 35 CNB cases, indicating potential interpretive errors. Of the 11 interpretive errors (including both suspicious and positive cases), 8 were adenocarcinomas, 1 squamous cell carcinoma, 1 metastatic renal cell carcinoma, and 1 lymphoma. The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas. Interpretive and sampling error cases were more likely to abut the pleura, while histopathologically, they tended to be necrotic and air-dried. The overall FN rate in this patient cohort is 3.5% (1.1% interpretive and 2.4% sampling errors). © 2014 Wiley Periodicals, Inc.

  14. Fine needle aspiration in the diagnosis and classification of hepatoblastoma: Analysis of 21 New Cases.

    PubMed

    Vlajnic, Tatjana; Brisse, Hervé J; Aerts, Isabelle; Fréneaux, Paul; Cellier, Cécile; Fabre, Monique; Klijanienko, Jerzy

    2017-02-01

    Diagnosis of hepatoblastoma (HBL) is based on characteristic clinical and radiological presentation, young age and marked elevation of serum α-fetoprotein (aFP). Fine needle aspiration (FNA) technique is successfully used in the diagnosis of hepatoblastoma. To evaluate the value of FNA in the diagnosis and subtyping of HBL, we report our experience correlated to histological sections (core needle biopsy, CNB). From 1991 to 2015, 21 cases from 20 patients were cytologically diagnosed as HBL. The patients were 15 males and 5 females, mean age being 3 years, and median age being 2 years and 4 months. Serum aFP levels ranged from negative to 1,285,000 ng/ml. We defined cytological criteria to diagnose fetal, embryonal, mesenchymal, and small cell undifferentiated components. The accurate cytological diagnosis of HBL was made in all cases; 8 cases exhibited a single component and 13 cases exhibited two or more components. Fetal and embryonal components were seen in 18 and 13 cases, respectively, and small cell undifferentiated component was seen in one case. Mesenchymal component was seen in 12 cases. Comparing cytology and histology, identical components were identified on both, FNA and CNB in 14 cases. When analyzing only the presence of epithelial components, 17 cases were concordant in both techniques. FNA allows to accurately diagnose HBL and recognize its histological subtypes. On the basis of high concordance between cytological and histological diagnosis, FNA is validated as an alternative diagnostic method to CNB. Diagn. Cytopathol. 2017;45:91-100. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Evolution of a rapid onsite evaluation (ROSE) service for endobronchial ultrasound guided (EBUS) fine needle aspiration (FNA) cytology in a UK Hospital: A 7 year audit.

    PubMed

    Stevenson, Tracey; Powari, Manish; Bowles, Christopher

    2018-05-13

    Endobronchial ultrasound fine needle aspiration (EBUS FNA) is a well-established procedure for the diagnosis and staging of lung cancer. We review our provision of this service at the Royal Devon and Exeter NHS Foundation Trust and the role of rapid onsite evaluation (ROSE) with the increasing demand for molecular markers in this era of personalized medicine. A review of the changes in the Endoscopy clinic over the 7 years from the introduction of EBUS at the end of 2010 until 2017 was carried out. This included the availability of material obtained for diagnosis, accurate subtyping, and molecular testing. We also assessed the success of molecular genetics DNA techniques from EBUS material versus formalin fixed paraffin embedded tissue (FFPE). A total of 1218 EBUS cases with ROSE were reported between 2011 and 2017 Percentage diagnostic rates were calculated as 83, 82, 84, 92, 93, 94, and 92 for 2011, 2012, 2013, 2014, 2015, 2016, and 2017, respectively. Availability of material for immunocytochemistry ranged from 86 to 100% over the 7 years. Molecular testing was successfully performed for EGFR in 89-100% of requested cases and ALK testing in 87-100% of requested cases. EBUS sourced material gave on average twice the amount of DNA and fewer amplicon repeats per patient compared to FFPE material. ROSE at EBUS FNA provides access to suitable material for molecular testing with increased yields in the form of needle washings for EGFR with FFPE materials for ALK and PDL1 testing. © 2018 Wiley Periodicals, Inc.

  16. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  17. The yield of adequate and conclusive fine-needle aspiration results in thyroid nodules is uniform across functional and goiter types.

    PubMed

    Liel, Y

    1999-01-01

    Relatively little is known about the cytological characteristics of hyperfunctioning (hot) thyroid nodules. Concern has been expressed that fine-needle aspiration (FNA) identifies hot nodules as follicular tumors or indeterminate, and as a consequence patients could be unnecessarily referred for surgery. Between 1979 and 1996, thyroid FNA was performed on 829 patients. Result of thyroid scan was available in 326; 69 (21%) patients had hot, and 257 (79%) had warm or cold thyroid nodules. Nodules in each of these major groups were divided into 2 subgroups: clinically solitary nodules and dominant nodules in multinodular goiters (MNG). The frequencies of adequate versus inadequate FNA samples, and of conclusive versus indeterminate FNA results were determined separately for each of the groups and subgroups. In addition, patients with hot nodules and overt hyperthyroidism were identified and evaluated separately. Bivariate analyses were performed for the frequency of adequate versus inadequate smears and conclusive versus indeterminate results between hot, toxic, and cold-warm nodules, and between solitary nodules and MNG. The frequency of adequate aspirations and conclusive results in the various groups and subgroups was found to be statistically indistinguishable. In conclusion, the yield of adequate samples and the rate of conclusive results of FNA in thyroid nodules is similar, irrespective of the functional state or of goiter presentation. Hot thyroid nodules do not seem to produce an increase in the rate of inadequate or indeterminate FNA results, and therefore, do not affect the overall performance of thyroid FNA.

  18. Surgical approach to TIR3 cytology class A prospective evaluation.

    PubMed

    D'Alessandro, Nicola; Fasano, Giovanni Michele; Gilio, Francesco; Iside, Giovanni; Izzo, Maria Lucia; Loffredo, Andrea; Pinto, Margherita; Tramontano, Salvatore; Tramutola, Giuseppe; Citro, Giuseppe

    2014-01-01

    Fine-needle aspiration (FNA) has proven to be a safe and reliable method of investigation of thyroid lesions. Referencing to European classification, the associated risk of malignancy for TIR3, category reserved for aspirates that contain architectural and/or nuclear atypia, is variable in such studies. Aims of study were evaluating safety of surgical approach, assessing perioperative parameters surgically related, and estimating neoplastic rate for TIR3 group. A prospective evaluation of all TIR3 submitted to thyroidectomy was conducted by assessing histopatohologic results between January 2005 and December 2012, considering two categories, positive (neoplastic) and negative (not neoplastic) group. Intraoperative and complication rate was analyzed on TIR3 population. A total of 1514 total thyroidectomy was performed from 2005 to 2012: a total of 148 cases was considered on TIR3 group. Positive cases amounted to 64 (43.2%), 29 of which were carcinoma (19.6% of total population) and 35 of which were adenoma, while negative cases amounted to 84 (56.8%). Sensitivity and specificity of TIR3 as neoplastic screening was 43.2% and 82.1%. A total of 32 linfectomies was performed (21.6% of group). Positive group presented a significant lower mean age than negative group (42.1 vs 56.2 years) TIR3 group represents a various category, with probably different malignancy risk. Our results and neoplasms rate confirmed that surgical option should be gold standard, in order to define atypical pattern and reduce delayed diagnoses. Choice of a second FNA or a imaging monitoring should be adopted for specific condition. Fine-needle aspiration, Thyroidectomy, TIR3, Thyroid cancer.

  19. Role of Core Needle Biopsy in the Management of Atypia/Follicular Lesion of Undetermined Significance Thyroid Nodules: Comparison with Repeat Fine-Needle Aspiration in Subcategory Nodules

    PubMed Central

    Na, Dong Gyu; Min, Hye Sook; Lee, Hunkyung; Won, Jae-Kyung; Seo, Hyo Bin; Kim, Ji-Hoon

    2015-01-01

    Background The role of repeat fine-needle aspiration (RFNA) or core needle biopsy (CNB) has not been established in nodules categorized as atypia/follicular lesion of undetermined significance (AUS/FLUS). Objective The purpose of this study was to retrospectively determine whether CNB is more useful for management decisions than RFNA at each subcategory of AUS/FLUS nodules. Methods This study included 158 AUS/FLUS nodules (≥1 cm) from 153 consecutive patients who underwent both RFNA and CNB. The AUS/FLUS nodules were subcategorized into nuclear atypia (NA) and follicular lesions with other atypia (FOA). The diagnostic results and rate of determined management by RFNA and CNB were compared at each subcategory. The diagnostic values of RFNA and CNB for malignancy were evaluated in nodules with final diagnoses. Results CNB showed a lower rate of AUS/FLUS diagnosis, higher rates of benign and follicular neoplasm or suspicious for a follicular neoplasm (FN/SFN) diagnoses (p ≤ 0.038), and marginally higher rates of malignant diagnosis than RFNA in the NA subcategory. CNB showed a higher rate of FN/SFN (p = 0.007) than RFNA in the FOA subcategory. CNB also demonstrated a higher rate of surgery decision than RFNA in both the NA subcategory (20.2 vs. 9.6%, p < 0.001) and FOA subcategory (20.8 vs. 5.6%, p = 0.007), and a higher rate of observation decision only in the NA subcategory (48.1 vs. 35.6%, p = 0.035). CNB demonstrated a higher diagnostic performance for malignancy overall in the nodules compared with RFNA. Conclusion CNB may be more useful for management decisions than RFNA in both the NA and FOA subcategories, and has the potential to be a first-line alternative diagnostic tool in initially diagnosed AUS/FLUS nodules. PMID:26558236

  20. Multidisciplinary Biomarkers of Early Mammary Carcinogenesis

    DTIC Science & Technology

    2009-04-01

    ABSTRACT The purpose of the proposed research is to develop novel optical technologies to identify high-risk premalignant changes in the breast ...Our proposed research will first test specific optical parameters in breast cancer cell lines and models of early mammary carcinogenesis, and then...develop methods to test the optical parameters in random periareolar fine needle aspirate (RPFNA) samples from women at high-risk for developing breast

  1. Fibrosarcoma in the distal radius and carpus of a four-year-old Persian.

    PubMed

    Cook, J L; Turk, J R; Tomlinson, J L; Corwin, L A; Shaw, D C

    1998-01-01

    A four-year-old Persian was presented for evaluation of a nonweight-bearing, left forelimb lameness. Radioulnar and pancarpal osteolysis with minimal periosteal reaction were seen on radiographs of the antebrachium. Cytological examinations of fine-needle aspirates and impression smears were suggestive of sarcoma. After forequarter amputation, histopathological examination provided a diagnosis of fibrosarcoma with axillary lymph-node metastasis.

  2. Needle aspiration of calcific deposits (NACD) for calcific tendinitis is safe and effective: Six months follow-up of clinical results and complications in a series of 431 patients.

    PubMed

    Oudelaar, Bart W; Schepers-Bok, Relinde; Ooms, Edwin M; Huis In 't Veld, Rianne; Vochteloo, Anne J H

    2016-04-01

    Although needle aspiration of calcific deposits (NACD) has proven to be an effective treatment for calcific tendinitis of the rotator cuff (CTRC) in patients who are resistant to conservative treatment, little is known about the effectiveness of NACD in terms of complete relief of symptoms and the effectiveness of repeated NACD procedures. Furthermore, analyses of complications of the procedure in large series are scarce. 431 consecutive patients with symptomatic CTRC treated by NACD were included in this retrospective cohort study. Short-term effects were assessed at two weeks post-treatment by using an 11-point numeric rating scale (NRS). The six months outcome was determined on a dichotomous symptom scale (symptom free or persistence of symptoms). NACD procedures performed within six months of a previous NACD procedure were considered repeated procedures. All complications that occurred within six months of the NACD procedure were registered. At two weeks post-treatment, a significant improvement of pain scores was noted (mean reduction of NRS: 4.4 points; p<0.001). 74% of patients had complete relief of symptoms at six months post-treatment. 143 (33.2%) patients required multiple treatments. These repeated procedures were equally effective as the primary procedure. Complications of the NACD procedure were seen in 31 (7.2%) patients: 21 patients (4.9%) developed a subacromial bursitis, seven patients (1.6%) a frozen shoulder and three patients (0.7%) developed a septic bursitis. Needle aspiration of calcific deposits (NACD) is an effective treatment for calcific tendinitis of the rotator cuff in the majority of patients. Approximately one third of the patients will require multiple treatments, which were equally effective as the primary procedure. Based on this, patients should not be withheld a second or even a third treatment in case of persistent symptoms. Furthermore, NACD has a low complication rate, the risk of infection should, however, always be accounted for. Retrospective study, level IV. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Molecular testing in lung cancer: fine-needle aspiration specimen adequacy and test prioritization prior to the CAP/IASLC/AMP Molecular Testing Guideline publication.

    PubMed

    Rafael, Oana C; Aziz, Mohamed; Raftopoulos, Harry; Vele, Oana E; Xu, Weisheng; Sugrue, Chiara

    2014-06-01

    Subtyping of lung carcinoma with immunohistochemistry is essential for diagnosis, whereas molecular testing (MT) is required for therapy guidance. In the current study, the authors report on MT performed on fine-needle aspiration specimens at the study institution over a 2-year period preceding the April 2013 College of American Pathologists (CAP)/International Association for the Study of Lung Cancer (IASLC)/Association for Molecular Pathology (AMP) Molecular Testing Guideline (MTG) publication. The database of the study institution was retrospectively queried for cases of lung and thoracic/lower cervical lymph node fine-needle aspiration specimens for 2011 through 2012. Of 246 selected cases, 26 featured a limited amount of material in cell blocks. MT increased significantly between 2011 and 2012 and was requested in 39.4% of cases (97 of 246 cases): 86 of those cases had at least 1 MT result and 11 had insufficient material for any MT. Anaplastic lymphoma kinase (ALK) testing was performed in 9 cases in which DNA was insufficient for epidermal growth factor receptor (EGFR) testing. In addition, 13 cases of adenocarcinoma/non-small cell lung carcinoma had at least 1 MT canceled because of insufficient DNA, but at the same time had an average of 3.46 immunohistochemical stains performed. Of all the cytology specimens, 10.6% featured limited material; however, no universally accepted testing sequence priority was available at the time the study was performed. As per the MTG, MT should take precedence over immunohistochemistry in cases of adenocarcinoma/non-small cell lung carcinoma. Approximately 5.3% of the specimens in the current study had insufficient material for MT while having multiple stains performed instead. The MTG also recommend performing EGFR before ALK testing; the authors found 9 cases with insufficient material for EGFR testing that had ALK testing performed. The results of the current study underscore the need for a testing prioritization algorithm in view of the MTG publication to serve as reference for both clinicians and pathologists. © 2014 American Cancer Society.

  4. Air embolism and maternal death from therapeutic abortion.

    PubMed

    Munsick, R A

    1972-05-01

    The case report of a fatal result in an abortion requested because X-ray diagnostic studies of the gallbladder and intestine had been made during an undiagnosed early pregnancy is presented. A uterine vacuum aspirator had not been purchased by the hospital. A portable laboratory vacuum pump with an appropriate suction trap was used. The apparatus had been used previously in several abortion cases. After dilatation of the cervix and insertion of the aspirating cannula, the pump was turned on. A sudden massive effusion of bloody froth issued from around the cannula. The cannula was removed immediately. It was found that the tubing had been incorrectly connected. The aspirator tube was connected with the pressure outlet of the pump. The tubing was then correctly placed and the uterus emptied. The patient was given succinyl choline, intubated, placed in the Trendelenburg position, and monitored cardiographically. About 30 seconds after the uterine insufflation blood pressure became unobtainable. The pulse slowed to 50 beats/minute and respiration diminished. Cardiac ausculation revealed no sounds. Respiration was maintained using oxygen through an endoctracheal tube. The pulse was still palpable and the EKG showed abnormal QRS complexes. Cyanosis then became evident. Closed chest cardiac massage was used for 1 minute but the patient became pulseless and QRS complexes were bizarre. Then the chest was opened and each ventricle was needled. From each ventricle of the distended heart air hissed under pressure through the needle vent site. The ascending aorta was needled and air escaped under pressure. Cardiac color and action improved when aided by massage. Iv isoproterenol and intracardiac epinephrine were given. An electric defibrillator converted the cardiac rhythm to a sinus rhythm. Norepinephirne brought about hypertension. Blood and albumin were given iv. The patient never regained consciousness. Tracheostomy and a feeding gastrostomy were required. Urinary and respiratory infections followed and the patient died after 2 1/2 months. Autopsy revealed tracheobronchitis, bronchopneumonia, and pulmonary edema. The brain showed extensive cerebral cortical necrosis. The heart was normal. This maternal death was preventable.

  5. Service Quality Of Diagnostic Fine Needle Aspiration Cytology In A Tertiary Care Hospital Of Lahore (Process Measure As Patient's Perspective).

    PubMed

    Rizvi, Zainab; Usmani, Rabia Arshed; Rizvi, Amna; Wazir, Salim; Zahra, Taskeen; Rasool, Hafza

    2017-01-01

    Quality of any service is the most important aspect for the manufacturer as well as the consumer. The primary objective of any nation's health system is to provide supreme quality health care services to its patients. The objective of this study was to assess the quality of diagnostic fine needle aspiration cytology service in a tertiary care hospital. As Patient's perspectives provide valuable information on quality of process, therefore, patient's perception in terms of satisfaction with the service was measured. In this cross sectional analytical study, 291 patients undergoing fine needle aspiration cytology in Mayo Hospital were selected by systematic sampling technique. Information regarding satisfaction of patients with four dimensions of service quality process, namely "procedure, sterilization, conduct and competency of doctor" was collected through interview on questionnaire. The questionnaire was developed on SERVQUAL model, a measurement tool, for quality assessment of services provided to patients. All items were assessed on 2- point likert scale (0=dissatisfied, 1=satisfied). Frequencies and percentages of satisfied and dissatisfied patients were recorded for each item and all items in each dimension were scored. If the percentage of sum of all item scores of a dimension was ≥60, the dimension was 'good quality'. Whereas <60% was 'poor quality' dimension. Data was analysed using epi-info-3.5.1. Fisher test was applied to check statistical significance. (p-value <0.05). Out of the 4 dimensions of service quality process, Procedure (48.8%), Sterilization (51.5%) and practitioner conduct (50.9%) were perceived as 'poor' by the patients. Only practitioner competency (67.4%) was perceived as 'good'. Comparison of dimensions of service quality scoring with overall level of patient satisfaction revealed that all 4 dimensions were significantly related to patient dissatisfaction (p<.05). The study suggests that service quality of therapeutic and diagnostic procedures in public hospitals should be routinely monitored from the patients' point of view as most aspects of service quality in public hospitals of Pakistan, require improvements. In this manner patient's satisfaction regarding use of services in public hospitals can be made better.

  6. High sensitive reflection type long period fiber grating biosensor for real time detection of thyroglobulin, a differentiated thyroid cancer biomarker: the Smart Health project

    NASA Astrophysics Data System (ADS)

    Quero, G.; Severino, R.; Vaiano, P.; Consales, M.; Ruvo, M.; Sandomenico, A.; Borriello, A.; Giordano, M.; Zuppolini, S.; Diodato, L.; Cutolo, A.; Cusano, A.

    2015-09-01

    We report the development of a reflection-type long period fiber grating (LPG) biosensor able to perform the real time detection of thyroid cancer markers in the needle washout of fine-needle aspiration biopsy. A standard LPG is first transformed in a practical probe working in reflection mode, then it is coated by an atactic-polystyrene overlay in order to increase its surrounding refractive index sensitivity and to provide, at the same time, the desired interfacial properties for a stable bioreceptor immobilization. The results provide a clear demonstration of the effectiveness and sensitivity of the developed biosensing platform, allowing the in vitro detection of human Thyroglobulin at sub-nanomolar concentrations.

  7. Development of a mechanics-based model of brain deformations during intracerebral hemorrhage evacuation

    NASA Astrophysics Data System (ADS)

    Narasimhan, Saramati; Weis, Jared A.; Godage, Isuru S.; Webster, Robert; Weaver, Kyle; Miga, Michael I.

    2017-03-01

    Intracerebral hemorrhages (ICHs) occur in 24 out of 100,000 people annually and have high morbidity and mortality rates. The standard treatment is conservative. We hypothesize that a patient-specific, mechanical model coupled with a robotic steerable needle, used to aspirate a hematoma, would result in a minimally invasive approach to ICH management that will improve outcomes. As a preliminary study, three realizations of a tissue aspiration framework are explored within the context of a biphasic finite element model based on Biot's consolidation theory. Short-term transient effects were neglected in favor of steady state formulation. The Galerkin Method of Weighted Residuals was used to solve coupled partial differential equations using linear basis functions, and assumptions of plane strain and homogeneous isotropic properties. All aspiration models began with the application of aspiration pressure sink(s), calculated pressures and displacements, and the use of von Mises stresses within a tissue failure criterion. With respect to aspiration strategies, one model employs an element-deletion strategy followed by aspiration redeployment on the remaining grid, while the other approaches use principles of superposition on a fixed grid. While the element-deletion approach had some intuitive appeal, without incorporating a dynamic grid strategy, it evolved into a less realistic result. The superposition strategy overcame this, but would require empirical investigations to determine the optimum distribution of aspiration sinks to match material removal. While each modeling framework demonstrated some promise, the superposition method's ease of computation, ability to incorporate the surgical plan, and better similarity to existing empirical observational data, makes it favorable.

  8. 18-gauge needle cap as adjunct to prevent kinking of endotracheal tube.

    PubMed

    Chan, Fuan Chiang; Kawamoto, Henry K; Bradley, James P

    2012-11-01

    A self-retaining Dingman mouth retractor is widely used to keep the mouth open during cleft palate and intraoral surgery. The airway is at risk of being crushed or occluded as the gag (tongue plate) of the Dingman mouth retractor is being pushed against the endotracheal tube.Kinking of the endotracheal tube between the teeth and Dingman mouth retractor has been reported even with the oral Ring-Adair-Elwyn or flexometallic or armored endotracheal tubes. To minimize kinking of the endotracheal tube and its consequent complications, we routinely insert an 18-gauge needle cap at the potential space between the teeth and the tongue plate (gag) of the Dingman mouth retractor, which is situated lateral to the endotracheal tube. In our experience of approximately 5000 intraoral cases using a Dingman mouth retractor and 18-gauge needle cap, we have not had any tooth avulsion or aspiration of the 18-gauge foreign body while maintaining a consistent and secured airway during cleft palate and intraoral surgery.

  9. Contemporary management of benign liver tumors.

    PubMed

    Gibbs, John F; Litwin, Alan M; Kahlenberg, Morton S

    2004-04-01

    Benign lesions of the liver represent diagnostic dilemmas, clinically and radiographically; however, certain clues can help the extensive differential diagnosis of both benign and malignant processes. Hemangiomas and simple cysts have very distinct and very specific radiographic characteristics, and if diagnosed, no further work-up is necessary. The remaining benign lesions have significant overlap, even though there are some more common characteristics to each of the entities. Still, differentiation of any particular lesion outside simple cysts or hemangioma may be difficult. It is reasonable and relatively simple, with minimal invasiveness, to perform US- or CT-guided, percutaneous core-needle biopsies. It is recommended that core biopsies be performed, because many of the benign entities have some overlapping histologic features, and if fine-needle aspirations are performed, a definitive diagnosis may be difficult to obtain. A definitive pathological diagnosis still cannot be made in some cases, even after needle biopsy. Therefore, a surgical resection or wedge resection may be necessary if a benign process cannot be definitively ruled out.

  10. Transvaginal Aspiration of Ovarian Cysts: Long-Term Follow-up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duke, D.; Colville, J.; Keeling, A.

    2006-06-15

    Background and purpose. Transvaginal aspiration of ovarian cysts has been advocated as a viable alternative to surgery in patients who are high-risk surgical candidates. We describe a retrospective study evaluating the results of transvaginal aspirations of benign ovarian cysts in patients at increased surgical risk, focusing on long-term follow-up for recurrence of the cyst and/or development of malignancy. Methods. Twenty-four women with ovarian cysts underwent 34 transvaginal drainages between October 1998 and December 2004. All patients were referred following diagnosis of a persistent ovarian cyst with a benign appearance on ultrasound. All patients were unsuitable candidates for surgery (history ofmore » previous pelvic surgery, n = 21; high risk for anesthesia, n = 1; and unsuitable for laparoscopy due to obesity, n = 2). Patients with a history of pregnancy, acute abdominal symptoms, or previous gynecologic malignancy were excluded. A 20G x 20 cm Chiba needle was used for transvaginal aspiration using an endocavity probe (Acuson XP, Mountain View, CA, USA; Siemens Sololine, Erlangen, Germany) and intravenous sedoanalgesia. Cysts were aspirated to dryness. Results. Long-term follow-up of patients was performed and revealed a recurrence rate of 75%. Eighty-three percent of cysts on the left and 42% of those on the right recurred. Nine of 15 (60%) patients with recurrence required further intervention. Two of 9 underwent surgical intervention only, 4 of 9 had repeat transvaginal aspiration(s) performed, and 3 of 9 had a combination of both transvaginal aspiration and surgery. No patient developed ovarian malignancy. Conclusion. Transvaginal cyst aspiration has many advantages including short hospital stay, rapid recovery, excellent patient tolerance, and a low rate of procedure-related complications. Our study demonstrates that ovarian cyst recurrence following transvaginal drainage is a more significant problem than previously documented, especially if the cyst is on the left side. However, when recurrences do occur, repeat transvaginal aspirations may be considered in the symptomatic patient.« less

  11. Painless treatment of hydrocele: EMLA cream anaesthesia and fibrin adhesive sclerotherapy.

    PubMed

    Cecchi, M; Sepich, C A; Pagni, G; Ippolito, C; Minervini, R; Fiorentini, L

    1997-01-01

    Sclerotherapy for hydroceles was performed in 18 patients. Cutaneous anaesthesia was induced with an anaesthetic cream (lidocaine and prilocaine, EMLA cream) and a fibrin sealant (Tissucol) was injected into the sac after fluid aspiration. Patients experienced no pain during needle insertion and sclerosant procedure; 2 recurrences were observed during follow-up. EMLA cream anaesthesia and fibrin adhesive sclerotherapy represent a useful alternative to surgical treatment of hydroceles.

  12. Magnetic Resonance Spectroscopy: An Objective Modality to Identify the Pathology of Breast Neoplasms

    DTIC Science & Technology

    1999-05-01

    Zealand Journal or Surgery Appendix IV: Attached Manuscript published in Life Sciences Appendix V: Attached Figures 1-13 Appendix VI: Attached Tables 1... early diagnosis and effective management. The triage of mammography, clinical examination and fine needle aspiration biopsy is currently used to...identify early breast cancers. Magnetic resonance imaging (MRI) has now been added to select women with breast abnormalities requiring biopsy. However

  13. Chondrosarcoma of the nasal septum.

    PubMed

    Indudharan, R; Das, P K; Azman, A A; Suhaiza, S

    1998-08-01

    A case of chondrosarcoma of the nasal septum is presented with the result of treatment. The patient was admitted for a growth in the nose of four years' duration. Fine needle aspiration for cytological examination was suggestive of squamous cell carcinoma. She was treated with lateral rhinotomy and wide excision followed by septorhinoplasty. Histological examination showed that the lesion was chondrosarcoma. The patient remained free of disease 26 months after surgery.

  14. Toward improving fine needle aspiration cytology by applying Raman microspectroscopy

    NASA Astrophysics Data System (ADS)

    Becker-Putsche, Melanie; Bocklitz, Thomas; Clement, Joachim; Rösch, Petra; Popp, Jürgen

    2013-04-01

    Medical diagnosis of biopsies performed by fine needle aspiration has to be very reliable. Therefore, pathologists/cytologists need additional biochemical information on single cancer cells for an accurate diagnosis. Accordingly, we applied three different classification models for discriminating various features of six breast cancer cell lines by analyzing Raman microspectroscopic data. The statistical evaluations are implemented by linear discriminant analysis (LDA) and support vector machines (SVM). For the first model, a total of 61,580 Raman spectra from 110 single cells are discriminated at the cell-line level with an accuracy of 99.52% using an SVM. The LDA classification based on Raman data achieved an accuracy of 94.04% by discriminating cell lines by their origin (solid tumor versus pleural effusion). In the third model, Raman cell spectra are classified by their cancer subtypes. LDA results show an accuracy of 97.45% and specificities of 97.78%, 99.11%, and 98.97% for the subtypes basal-like, HER2+/ER-, and luminal, respectively. These subtypes are confirmed by gene expression patterns, which are important prognostic features in diagnosis. This work shows the applicability of Raman spectroscopy and statistical data handling in analyzing cancer-relevant biochemical information for advanced medical diagnosis on the single-cell level.

  15. Large cell neuroendocrine carcinoma of the parotid gland: case report and literature review.

    PubMed

    Casas, Pablo; Bernáldez, Ricardo; Patrón, Mercedes; López-Ferrer, Pilar; García-Cabezas, Miguel A

    2005-03-01

    A 74-year-old male presented with a large polinodular mass in the neck. Fine needle aspiration cytology (FNAC) showed an undifferentiated large cell carcinoma. Computed tomography (CT) showed a large parotid mass with multiple satelite nodules. The remaining radiological studies were normal. Radical parotidectomy was performed. The tumor was a large cell carcinoma with neuroendocrine features and positive immunostain for neuroendocrine markers. The patient received postoperative radiotherapy and was free of tumor eight months later. Only four cases of large cell neuroendocrine carcinoma (LCNEC) of the salivary gland have been communicated. All of them have involved the parotid gland. This tumor presents in elderly patients as a large infiltrating parotid mass. Fine needle aspiration cytology serves to recognize the carcinoma, but it fails in recognizing the neuroendocrine features of the tumor. The histopathological features of this tumor are the same as in other organs. Chromogranin and synaptophysin are useful immunohistochemical markers. A primary location of the tumor in another organ, specially the lung, should be ruled out. Surgery is the main treatment modality and can be complemented with postoperative radiotherapy. The prognosis seems to be poor. More studies are needed to better define the therapeutical alternatives and prognostic factors of these rare tumors.

  16. Technical Advances in Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition for Pancreatic Cancers: How Can We Get the Best Results with EUS-Guided Fine Needle Aspiration?

    PubMed Central

    Kedia, Prashant; Gaidhane, Monica

    2013-01-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320

  17. Repeat Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Patients with Suspected Pancreatic Cancer: Diagnostic Yield and Associated Change in Access to Appropriate Care

    PubMed Central

    Stanger, Dylan; Shuster, Constantin; Telford, Jennifer; Lam, Eric

    2016-01-01

    Background. There is a high incidence of inconclusive cytopathology at initial EUS-FNA (endoscopic ultrasound-guided fine-needle aspiration) for suspected malignant pancreatic lesions. To obtain appropriate preoperative or palliative chemotherapy for pancreatic cancer, definitive cytopathology is often required. The utility of repeat EUS-FNA is not well established. Methods. A retrospective cohort study was conducted evaluating the yield of repeat EUS-FNA in determining a cytological diagnosis in patients who had undergone a prior EUS-FNA for diagnosis of suspected malignant pancreatic lesions with inconclusive cytopathology. The wait times to the second procedure and to decisions regarding therapy were calculated. Results. Overall, 45 repeat EUS-FNA procedures were performed over seven years for suspected malignant pancreatic lesions. Cytopathological class (I to IV) changed between first and second EUS-FNA in 32 patients (71%). Of 34 patients with an initially nonconclusive diagnosis, 20 had a conclusive diagnosis (59%) on repeat EUS-FNA. The cumulative yield after repeat EUS-FNA for definite pancreatic adenocarcinoma was 7 (16%). The median time interval between first and second EUS-FNA was 31 (7–175) days. Conclusions. A substantial number of patients had a definitive diagnosis of adenocarcinoma on repeat FNA and were, therefore, subsequently able to access appropriate care. PMID:27648440

  18. Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea

    PubMed Central

    Hwang, Chang Yun; Song, Tae Jun; Moon, Sung-Hoon; Lee, Don; Park, Do Hyun; Seo, Dong Wan; Lee, Sung Koo; Kim, Myung-Hwan

    2009-01-01

    Background/Aims Although endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports about its performance. The aim of this study was to assess the utility of EUS-FNA without on-site cytopathologist in establishing the diagnosis of solid pancreatic and peripancreatic masses from a single institution in Korea. Methods Medical records of 139 patients who underwent EUS-FNA for pancreatic and peripancreatic solid mass in the year 2007, were retrospectively reviewed. By comparing cytopathologic diagnosis of FNA with final diagnosis, sensitivity, specificity, and accuracy were determined, and factors influencing the accuracy as well as complications were analyzed. Results One hundred twenty out of 139 cases had final diagnosis of malignancy. Sensitivity, specificity, and accuracy of EUS-FNA were 82%, 89%, and 83%, respectively, and positive and negative predictive values were 100% and 46%, respectively. As for factors influencing the accuracy of FNA, lesion size was marginally significant (p-value 0.08) by multivariate analysis. Conclusions EUS-FNA performed without on-site cytopathologist was found to be accurate and safe, and thus EUS-FNA should be a part of the standard management algorithm for pancreatic and peripancreatic mass. PMID:20431733

  19. Use of Simulators to Explore Specialty Recommendation for a Palpable Breast Mass

    PubMed Central

    Laufer, Shlomi; Ray, Rebecca D.; D'Angelo, Anne-Lise D.; Jones, Grace F.; Pugh, Carla M.

    2015-01-01

    Background The study aim was to evaluate recommendation patterns of different specialties for the work-up of a palpable breast mass using simulated scenarios and clinical breast examination (CBE) models. Methods Study participants were a convenience sample of physicians (n=318) attending annual surgical, family practice and obstetrics and gynecology (OB/GYN) conferences. Two different silicone-based breast models (superficial mass vs chest wall mass) were used to test CBE skills and recommendation patterns (imaging, tissue sampling, and follow-up). Results Participants were more likely to recommend mammography (p<.001) and core biopsy (p<.0001) and less likely to recommend needle aspiration (p<.043) and 1-month follow up (p<.001) for the chest wall mass compared to the superficial mass. Family practitioners were less likely to recommend ultrasound (p<.001) and OB/GYNs were less likely to recommend mammogram (p<.006) across models. Surgeons were more likely to recommend core biopsy and less likely to recommend needle aspiration across models (p<.001) Conclusions Recommendation patterns differed across the two models in line with existing practice guidelines. Additionally, differences in practice patterns between primary care and specialty providers may represent varying clinician capabilities, health care resources, and individual preferences. Our work shows that simulation may be used to track adherence to practice guidelines for breast masses. PMID:26198334

  20. Fine-needle aspiration biopsy of large-cell undifferentiated carcinoma of the salivary glands: presentation of two cases, literature review, and differential cytodiagnosis of high-grade salivary gland malignancies.

    PubMed

    Moore, J G; Bocklage, T

    1998-07-01

    Primary undifferentiated carcinoma of the salivary glands is a rare, high-grade neoplasm which accounts for a very small number (1-5.5%) of malignant salivary gland tumors. The large-cell variant (LCU) is less well-characterized than the small-cell form. We report on the fine-needle aspiration (FNA) biopsy findings of 2 cases of LCU, one arising in the parotid gland, and the other in a buccal mucosa accessory salivary gland. The 2 cases were similar in composition: isolated and loosely cohesive large cells with abundant cytoplasm, and variability pleomorphic nuclei with prominent nucleoli. One case also featured multinucleated tumor giant cells and macrophage polykaryons; the latter has not previously been described in FNA biopsies of LCU. There was no evidence of squamous, myoepithelial, or widespread mucinous differentiation by morphological, cytochemical, or immunohistochemical analyses (focal rare mucin production identified on special stains in one case). The differential diagnosis is lengthy and consists of other high-grade primary salivary gland malignancies as well as metastatic lesions, including melanoma. The pattern of immunohistochemical reactivity (positive keratin, negative S-100, and HMB-45 antigens), and lack of conspicuous mucin production of significant lymphoidinfiltrate, were useful in establishing the correct diagnosis.

  1. Atypia in random periareolar fine-needle aspiration affects the decision of women at high risk to take tamoxifen for breast cancer chemoprevention.

    PubMed

    Goldenberg, Vanessa K; Seewaldt, Victoria L; Scott, Victoria; Bean, Gregory R; Broadwater, Gloria; Fabian, Carol; Kimler, Bruce; Zalles, Carola; Lipkus, Isaac M

    2007-05-01

    Random periareolar fine-needle aspiration (RPFNA) is a research procedure designed to (a) evaluate short-term breast cancer risk in women at high risk for developing breast cancer, and (b) track response to chemoprevention. Of import, cellular atypia in breast RPFNA is prospectively associated with a 5.6-fold increase in breast cancer risk in women at high risk. Among 99 women attending a clinic for high-risk breast cancer, we explored the effects of RPFNA cytology results on decision making pertaining to the use of tamoxifen for breast cancer chemoprevention. No patient with nonproliferative or hyperplastic cytology subsequently elected to take tamoxifen. Only 7% of subjects with borderline atypia elected to take tamoxifen. In contrast, 50% with atypia elected to take tamoxifen. These results suggest that the provision of a biomarker of short-term risk can affect the motivation to take tamoxifen for chemoprevention. This conclusion is informative given that tamoxifen, due to its side effects, is often underused by women at high risk of developing breast cancer. Further research is needed to determine the mechanisms through which RPFNA results affect the decision to use tamoxifen, or any other breast cancer chemopreventive agent.

  2. Cytopathologist-performed and ultrasound-guided fine needle aspiration cytology enhances diagnostic accuracy and avoids pitfalls: An overview of 20 years of personal experience with a selection of didactic cases.

    PubMed

    Paksoy, Nadir; Ozbek, Busra

    2018-01-01

    Over the last few decades, fine needle aspiration cytology (FNA) has emerged as a SAFE (Simple, Accurate, Fast, Economical) diagnostic tool based on the morphologic evaluation of cells. The first and most important step in obtaining accurate results from FNA is to procure sufficient and representative material from the lesion and to appropriately transfer this material to the laboratory. Unfortunately, the most important aspect of this task occurs beyond the control of the cytopathologist, a key reason for obtaining unsatisfactory results with FNA. There is growing interest in the field of cytology in "cytopathologist-performed ultrasound (US)-guided FNA," which has been reported to yield accurate results. The first author has been applying FNA in his own private cytopathology practice with a radiologist and under the guidance of US for more than 20 years. This study retrospectively reviews the utility of this practice. We present a selection of didactic examples under different headings that highlight the application of FNA by a cytopathologist, accompanied by US, under the guidance of a radiologist, in the form of an "outpatient FNA clinic." The use of this technique enhances diagnostic accuracy and prevents pitfalls. The highlights of each case are also outlined as "take-home messages."

  3. Role of fine needle aspiration cytology in the preoperative investigation of branchial cysts.

    PubMed

    Slater, Jacqueline; Serpell, Jonathan W; Woodruff, Stacey; Grodski, Simon

    2012-01-01

    Successful preoperative diagnosis of a branchial cyst requires a systematic approach. The aim of this study was to evaluate methods of investigation of a lateral neck swelling suspicious for a branchial cyst, and to highlight cases where a less benign cause for the swelling should be suspected and therefore management altered appropriately. A retrospective case study of 24 patients with presumed branchial cysts managed operatively was undertaken. Demographic, clinical, imaging, cytology and histopathological data were analysed to formulate an approach to the work-up of a lateral neck swelling suspected to be a branchial cyst. All 24 patients presented with a lateral neck mass thought to be a branchial cyst preoperatively underwent preoperative fine-needle aspiration cytology. The overall accuracy of cytology in predicting a benign branchial cyst histopathologically was 83.3% (20 out of 24). Successful preoperative diagnosis of a branchial cyst requires a combination of imaging and cytology. If there is concern that a lateral neck swelling is not a branchial cyst on clinical, imaging or cytological features, then a full preoperative work-up, including computed tomography scan of the neck and upper aero-digestive tract endoscopy should be performed, prior to an excisional biopsy. © 2011 The Authors. ANZ Journal of Surgery © 2011 Royal Australasian College of Surgeons.

  4. Evaluation of usefulness of fine-needle aspiration cytology in the diagnosis of tumours of the accessory parotid gland: a preliminary analysis of a case series in Japan.

    PubMed

    Iguchi, Hiroyoshi; Wada, Tadashi; Matsushita, Naoki; Oishi, Masahiro; Teranishi, Yuichi; Yamane, Hideo

    2014-07-01

    The accuracy and sensitivity of fine-needle aspiration cytology (FNAC) in this analysis were not satisfactory, and the false-negative rate seemed to be higher than for parotid tumours. The possibility of low-grade malignancy should be considered in the surgical treatment of accessory parotid gland (APG) tumours, even if the preoperative results of FNAC suggest that the tumour is benign. Little is known about the usefulness of FNAC in the preoperative evaluation of APG tumours, probably due to the paucity of APG tumour cases. We examined the usefulness of FNAC in the detection of malignant APG tumours. We conducted a retrospective analysis of 3 cases from our hospital, along with 18 previously reported Japanese cases. We compared the preoperative FNAC results with postoperative histopathological diagnoses of APG tumours and evaluated the accuracy, sensitivity, specificity and false-negative rates of FNAC in detecting malignant APG tumours. There were four false-negative cases (19.0%), three of mucoepidermoid carcinomas and one of malignant lymphoma. One false-positive result was noted in the case of a myoepithelioma, which was cytologically diagnosed as suspected adenoid cystic carcinoma. The accuracy, sensitivity and specificity of FNAC in detecting malignant tumours were 76.2%, 60.0% and 90.9%, respectively.

  5. Next-generation sequencing for molecular diagnosis of lung adenocarcinoma specimens obtained by fine needle aspiration cytology

    NASA Astrophysics Data System (ADS)

    Qiu, Tian; Guo, Huiqin; Zhao, Huan; Wang, Luhua; Zhang, Zhihui

    2015-06-01

    Identification of multi-gene variations has led to the development of new targeted therapies in lung adenocarcinoma patients, and identification of an appropriate patient population with a reliable screening method is the key to the overall success of tumor targeted therapies. In this study, we used the Ion Torrent next-generation sequencing (NGS) technique to screen for mutations in 89 cases of lung adenocarcinoma metastatic lymph node specimens obtained by fine-needle aspiration cytology (FNAC). Of the 89 specimens, 30 (34%) were found to harbor epidermal growth factor receptor (EGFR) kinase domain mutations. Seven (8%) samples harbored KRAS mutations, and three (3%) samples had BRAF mutations involving exon 11 (G469A) and exon 15 (V600E). Eight (9%) samples harbored PIK3CA mutations. One (1%) sample had a HRAS G12C mutation. Thirty-two (36%) samples (36%) harbored TP53 mutations. Other genes including APC, ATM, MET, PTPN11, GNAS, HRAS, RB1, SMAD4 and STK11 were found each in one case. Our study has demonstrated that NGS using the Ion Torrent technology is a useful tool for gene mutation screening in lung adenocarcinoma metastatic lymph node specimens obtained by FNAC, and may promote the development of new targeted therapies in lung adenocarcinoma patients.

  6. Perivascular Epithelioid Cell Tumor (PEComa) of Pancreas Diagnosed Preoperatively by Endoscopic Ultrasound-Guided Fine-Needle Aspiration: A Case Report and Review of Literature.

    PubMed

    Collins, Katrina; Buckley, Tinera; Anderson, Kevin; Karasik, Michael; Ligato, Saverio

    2017-01-01

    Perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare mesenchymal tumors and to our knowledge, only 17 cases have been reported in the English literature to date. We report our experience with a new case of primary pancreatic PEComa diagnosed preoperatively by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) complemented by tissue cell block and immunohistochemistry. The patient was a 54-year-old female whose chief complaint was intermittent severe right upper quadrant abdominal pain. Computed-tomography (CT) imaging revealed a mass between the head and the body of the pancreas. EUS-FNA smear preparation was obtained but was nondiagnostic. However, examination of the tissue cell block showed sheets of epithelioid cells with abundant eosinophilic cytoplasm and immunohistochemistry studies revealed positivity for both melanocytic (HMB-45 and Melan-A) and smooth muscle markers (actin and desmin). A diagnosis of PEComa was made and an uncomplicated middle pancreatectomy was performed. Our case and review of the literature demonstrates that EUS-FNA complemented with tissue cell block increases cellular yield, improved preoperative diagnostic accuracy, and may assist the surgeon in planning conservative surgical management. Diagn. Cytopathol. 2017;45:59-65. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Interphase cytogenetics of prostatic carcinoma in fine needle aspirate smears of radical prostatectomy specimens: A practical screening tool?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, R.Y.; Troncoso, P.; El-Naggar, A.K.

    1994-09-01

    Identification of chromosomal aberrations that may be used for diagnostic or prognostic evaluation of prostatic adenocarcinoma has been the subject of great interest. In a previous study, we applied the fluorescence in situ hybridization (FISH) method on paraffin-embedded material to show that trisomy 7 was associated with the progression of human prostate cancer. In this study, we attempted to assess the utility of the FISH technique in detecting aneuploidy in fine needle aspirate (FNA) smears of prostatic tissues and to compare FISH results with that of DNA flow cytometry (FCM). Paired samples of normal and tumor FNA smears were obtainedmore » from 10 radical prostatectomy specimens. Dual-color chromosomes 7 and 9-specific centromeric DNA probes were used for FISH. FISH analysis demonstrated increased frequencies of trisomy 7 cells in all 10 tumors studied when compared with the paired normals. In contrast, 6 of 10 tumors were determined to be diploid by FCM. Our results show that FNA of radical prostatectomy specimens is a practical method for obtaining suitable material for both FISH and FCM analyses of prostate carcinoma. Thus, interphase FISH may be a practical screening tool to determine aneuploidy in FNA smears of prostatic carcinoma.« less

  8. Technical description of endoscopic ultrasonography with fine-needle aspiration for the staging of lung cancer.

    PubMed

    Kramer, Henk; van Putten, John W G; Douma, W Rob; Smidt, Alie A; van Dullemen, Hendrik M; Groen, Harry J M

    2005-02-01

    Endoscopic ultrasonography (EUS) is a novel method for staging of the mediastinum in lung cancer patients. The recent development of linear scanners enables safe and accurate fine-needle aspiration (FNA) of mediastinal and upper abdominal structures under real-time ultrasound guidance. However, various methods and equipment for mediastinal EUS-FNA are being used throughout the world, and a detailed description of the procedures is lacking. A thorough description of linear EUS-FNA is needed. A step-by-step description of the linear EUS-FNA procedure as performed in our hospital will be provided. Ultrasonographic landmarks will be shown on images. The procedure will be related to published literature, with a systematic literature search. EUS-FNA is an outpatient procedure under conscious sedation. The typical linear EUS-FNA procedure starts with examination of the retroperitoneal area. After this, systematic scanning of the mediastinum is performed at intervals of 1-2cm. Abnormalities are noted, and FNA of the abnormalities can be performed. Specimens are assessed for cellularity on-site. The entire procedure takes 45-60 min. EUS-FNA is minimally invasive, accurate, and fast. Anatomical areas can be reached that are inaccessible for cervical mediastinoscopy. EUS-FNA is useful for the staging of lung cancer or the assessment and diagnosis of abnormalities in the posterior mediastinum.

  9. Fine-Needle Aspiration of Metastatic Central Type Primitive Neuroectodermal Tumors in Patients with a Germ Cell Tumor.

    PubMed

    Chen, Shaoxiong; Idrees, Muhammad; Lin, Jingmei; Wu, Howard H

    2017-01-01

    Central type primitive neuroectodermal tumors (PNET) are some of the most frequent somatic type tumors derived from germ cell tumors and can metastasize. We studied the cytomorphological features of metastatic central type PNET by fine-needle aspiration (FNA). A computerized search of our laboratory information system was performed for the 9-year period from 2005 through 2014 to identify all cytology cases in which a diagnosis of metastatic central type PNET had been rendered. A total of 5 FNA cases were collected and direct smears were reexamined. All patients had a history of testicular or ovarian germ cell tumors. Direct smears displayed single and clusters of atypical round to oval cells with scant to moderate cytoplasm. Abundant naked nuclei were present in Diff-Quik-stained smears with mild to marked crushed artifacts and nuclear molding. Tumor cells showed fine granular chromatin, nuclear size variation (up to 1:3), and one or more small nucleoli. Pseudorosettes (Homer Wright-like rosette) were noticed in 1 case. Tumor cells were commonly positive for synaptophysin. Metastatic PNET can be reliably diagnosed by FNA. Differential diagnoses include Ewing sarcoma/peripheral PNET, alveolar rhabdomyosarcoma, neuroblastoma, etc. It is important to be familiar with this entity to avoid diagnostic pitfalls. © 2017 S. Karger AG, Basel.

  10. Progression from on-site to point-of-care fine needle aspiration service: Opportunities and challenges

    PubMed Central

    Gupta, Prabodh K

    2010-01-01

    Background Standard-of-care requires the availability of an efficient, economical and accurate on-site fine needle aspiration (FNA) service. Presence of a trained individual during the procedure ensures an improved patient care. Appropriate selection of the equipment, interaction with the clinicians and compliance with the various regulations during the procedure is essential. This is often done by an on-site FNA service. Organization and implementation of such a system in a large academic center is challenging. Method we reviewed the ambulatory care needs in the new Perelman Center for Advanced Medicine (PeCAM). Multiple (9) FNA sites have been established keeping in view the patient's convenience, clinic demands, various regulatory requirements and laboratory staff. Each location has dedicated FNA station with microscopes and supplies. In addition, state- ofthe -art technologies including a mobile FNA cart (Penn-A- Cart), remote specimen evaluation (TeleCyP) have been incorporated. Results The new set up is extremely efficient and much valued by the patients and the clinicians. It has improved patient care. Conclusion With necessary investments and resources a point-of-care FNA service has been created which has improved patient care. This, albeit with certain modifications may serve as a model for FNA service. PMID:20607093

  11. [A case of pulmonary abscess in which Haemophilus parainfluenzae and Streptococcus intermedius were isolated by percutaneous needle aspiration].

    PubMed

    Miyamoto, Atsushi; Tsuboi, Eiyasu; Takaya, Hisashi; Sugino, Keishi; Sakamoto, Susumu; Kawabata, Masateru; Kishi, Kazuma; Narui, Koji; Homma, Sakae; Nakatani, Tatsuo; Nakata, Koichiro; Yoshimura, Kunihiko

    2006-08-01

    Some microbes, including the Bacteroides species, Staphylococcus aureus and Streptococcus milleri groups, can cause pulmonary abscess. Haemophilus parainfluenzae is usually categorized as one of the normal flora which colonizes in the ears and the nasopharynx, and it has been long considered that H. parainfluenzae has little pathogenicity in the lower respiratory tract and lung parenchymal. In this report, we present a case of pulmonary abscess caused by both H. parainfluenzae and Streptococcus intermedius. The patient was a 75-year-old man who had had total esophageo-gastrectomy because of esophageal cancer. He presented with purulent sputum, and chest X-ray film showed a dense consolidation in the right upper lung field. CT-guided transcutaneous fine needle aspiration was performed as a diagnostic procedure. Since both H. parainfluenzae and S. intermedius had been isolated from the lesion, pulmonary abscess caused by these two pathogens was diagnosed. The patient was treated with panipenem/betamipron, and his symptoms and pulmonary infiltrates on the chest X-ray film improved thereafter. So far, very few cases have been reported in which H. parainfluenzae caused lower respiratory tract infection. Although S. intermedius is known as one of the pathogens of pulmonary abscess, it is possible that H. parainfluenzae could also be pathogenic in infectious diseases of the lung.

  12. Endoscopic ultrasound-guided fine-needle aspiration with liquid-based cytologic preparation in the diagnosis of primary pancreatic lymphoma.

    PubMed

    Rossi, Esther Diana; Larghi, Alberto; Verna, Elizabeth C; Martini, Maurizio; Galasso, Domenico; Carnuccio, Antonella; Larocca, Luigi Maria; Costamagna, Guido; Fadda, Guido

    2010-11-01

    The diagnosis subtyping of lymphoma on specimens collected by endoscopic ultrasound fine-needle aspiration (EUS-FNA) can be extremely difficult. When a cytopathologist is available for the on-site evaluation, the diagnosis may be achieved by applying flow cytometric techniques. We describe our experience with immunocytochemistry (ICC) and molecular biology studies applied on EUS-FNA specimens processed with a liquid-based cytologic (LBC) preparation for the diagnosis of primary pancreatic lymphoma (PPL). Three patients with a pancreatic mass underwent EUS-FNA. The collected specimens were processed with the ThinPrep method for the cytologic diagnosis and eventual additional investigations. A morphologic picture consistent with PPL was found on the LBC specimens of the 3 patients. Subsequent ICC and molecular biology studies for immunoglobulin heavy chain gene rearrangement established the diagnosis of pancreatic large B-cell non-Hodgkin lymphoma in 2 patients and a non-Hodgkin lymphoma with plasmoblastic/immunoblastic differentiation in the remaining one. An LBC preparation can be used to diagnose and subtype PPL by applying ICC and molecular biology techniques to specimens collected with EUS-FNA. This method can be an additional processing method for EUS-FNA specimens in centers where on-site cytopathologist expertise is not available.

  13. Detection of mitochondrial DNA mutations in primary breast cancer and fine-needle aspirates.

    PubMed

    Parrella, P; Xiao, Y; Fliss, M; Sanchez-Cespedes, M; Mazzarelli, P; Rinaldi, M; Nicol, T; Gabrielson, E; Cuomo, C; Cohen, D; Pandit, S; Spencer, M; Rabitti, C; Fazio, V M; Sidransky, D

    2001-10-15

    To determine the frequency and distribution of mitochondrial DNA mutations in breast cancer, 18 primary breast tumors were analyzed by direct sequencing. Twelve somatic mutations not present in matched lymphocytes and normal breast tissues were detected in 11 of the tumors screened (61%). Of these mutations, five (42%) were deletions or insertions in a homopolymeric C-stretch between nucleotides 303-315 (D310) within the D-loop. The remaining seven mutations (58%) were single-base substitutions in the coding (ND1, ND4, ND5, and cytochrome b genes) or noncoding regions (D-loop) of the mitochondrial genome. In three cases (25%), the mutations detected in coding regions led to amino acid substitutions in the protein sequence. We then screened an additional 46 primary breast tumors with a rapid PCR-based assay to identify poly-C alterations in D310, and we found seven more cancers with alterations. Using D310 mutations as clonal marker, we detected identical changes in five of five matched fine-needle aspirates and in four of four metastases-positive lymph nodes. The high frequency of D310 alterations in primary breast cancer combined with the high sensitivity of the PCR-based assays provides a new molecular tool for cancer detection.

  14. DIAGNOSIS OF ENDOCRINE DISEASE: High-yield thyroid fine-needle aspiration cytology: an update focused on ancillary techniques improving its accuracy.

    PubMed

    Bongiovanni, M; Trimboli, P; Rossi, E D; Fadda, G; Nobile, A; Giovanella, L

    2016-02-01

    Thyroid fine-needle aspiration (FNA) cytology is a fast growing field. One of the most developing areas is represented by molecular tests applied to cytological material. Patients that could benefit the most from these tests are those that have been diagnosed as 'indeterminate' on FNA. They could be better stratified in terms of malignancy risk and thus oriented with more confidence to the appropriate management. Taking in to consideration the need to improve and keep high the yield of thyroid FNA, professionals from various fields (i.e. molecular biologists, endocrinologists, nuclear medicine physicians and radiologists) are refining and fine-tuning their diagnostic instruments. In particular, all these developments aim at increasing the negative predictive value of FNA to improve the selection of patients for diagnostic surgery. These advances involve terminology, the application of next-generation sequencing to thyroid FNA, the use of immunocyto- and histo-chemistry, the development of new sampling techniques and the increasing use of nuclear medicine as well as molecular imaging in the management of patients with a thyroid nodule. Herein, we review the recent advances in thyroid FNA cytology that could be of interest to the 'thyroid-care' community, with particular focus on the indeterminate diagnostic category. © 2016 European Society of Endocrinology.

  15. Learning curve of thyroid fine-needle aspiration biopsy.

    PubMed

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Cytotechnologist performance for screening microfollicular atypia in indeterminate thyroid fine-needle aspirates.

    PubMed

    VandenBussche, Christopher J; Olson, Matthew T; Adams, Christina; Ali, Syed Z

    2014-01-01

    We previously identified a high level of accuracy among our cytotechnologists (CTs) for identifying nuclear atypia in thyroid fine-needle aspiration (FNA) specimens. Herewith, we present our CT performance at screening for microfollicular atypia. 8,814 thyroid FNA specimens were identified in our archives, all screened by 1 of 11 CTs and signed out by a cytopathologist. A subsample of cases was categorized either as atypia of uncertain significance (AUS) with microfollicular proliferation (AUS-F) or suspicious for a follicular neoplasm (SFN). The agreement rate was low between CTs and cytopathologists for SFN and AUS-F. Only 55.8% of SFN screening diagnoses were upheld; 27.9% were downgraded to AUS, 10.4% were downgraded to benign, and 5% were upgraded. Of AUS-F screening diagnoses, 35.5% were upheld, 33.7% were downgraded to benign, and 20.2% were upgraded to SFN. Among all cases, two-step discrepancies were uncommon. Most disagreements were one-category discrepancies between AUS-F and SFN. The evaluation of microfollicular atypia is challenging given that certain follicular lesions cannot be definitively diagnosed on cytology, a high level of subjectivity is involved in the interpretation of such lesions, and the presence of nuclear or Hurthle cell atypia may complicate the diagnosis. © 2014 S. Karger AG, Basel.

  17. CD 99 immunocytochemistry in solid pseudopapillary tumor of pancreas: A study on fine-needle aspiration cytology smears.

    PubMed

    Ghosh, Ranajoy; Mallik, Saumya R; Mathur, Sandeep R; Iyer, Venkateswaran K

    2013-07-01

    Solid pseudopapillary tumor of pancreas (SPTP) is a rare pancreatic tumor of uncertain histogenesis usually affecting young women. Though these tumors have characteristic cytomorphology, it is sometimes difficult to differentiate them from neuroendocrine tumors of the pancreas. We reviewed cases of SPTP to delineate the diagnostic cytological features and also observed utility of CD 99 (MIC 2) immunostaining to aid in the diagnosis of this tumor. This study was designed to demonstrate the utility of CD 99 immunostaining along with cytological features for making a pre-operative diagnosis and delineating it from the neuroendocrine tumor of pancreas which is a close mimic. Cytomorphological features of 11 cases of solid pseudopapillary neoplasm diagnosed by pre-operative fine-needle aspiration cytology (FNAC) at our institute were reviewed. Immunocytochemistry for CD 99 was also performed on the smears. All the cases had cellular smears with monomorphic cells lying singly, as loosely cohesive clusters as well as forming delicate pseudopapillae. Presence of intra and extra-cellular basement membrane material, background foamy macrophages and nuclear grooves were the other salient features. Immunocytochemistry for CD 99 could be performed on eight cases and demonstrated typical paranuclear dot-like positivity. Pre-operative early diagnosis of SPTP can be made by FNAC which can further be aided by CD 99 immunocytochemistry.

  18. Association between Breast Cancer Recurrence and Cellular Dissociation Assessed Using Fine-Needle Aspiration.

    PubMed

    Koike, Etsuko; Iwaya, Keiichi; Watanabe, Akinori; Miyake, Shinji; Sato, Eiichi; Ishikawa, Takashi

    2016-01-01

    To determine the associations between breast cancer recurrence and cytological findings of fine-needle aspiration cytology (FNAC). The study included 117 women who had undergone a modified radical mastectomy for invasive ductal carcinoma of the breast. FNAC samples of these patients were reexamined, and cytological findings, such as cellular dissociation, nuclear pleomorphism, nuclear atypia, chromatin pattern, and nuclear size, were scored. Uni- and multivariate analyses were performed to determine the prognostic significance of the cytological findings. Corresponding cancer tissues were immunostained for estrogen receptor, progesterone receptor, human epidermal growth factor 2 (HER2), p53, and E-cadherin to determine their associations with cytological findings. Coexpression of Arp2 and WAVE2 was also examined immunohistochemically as a cell locomotion signal. Cellular dissociation (p = 0.0259) and nuclear size (p = 0.0417) were significantly associated with cancer recurrence. Multivariate analysis showed that cellular dissociation and histological grade were significant independent predictors of cancer recurrence. Cellular dissociation was found to be associated with coexpression of Arp2 and WAVE2 (p = 0.0356) and HER2 (p = 0.0469). The cytological finding of cell dissociation was associated with the activation of Arp2 and WAVE2 signals and was an independent predictor of recurrence. © 2016 S. Karger AG, Basel.

  19. Sterile Fluid Collections in Acute Pancreatitis: Catheter Drainage Versus Simple Aspiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walser, Eric M.; Nealon, William H.; Marroquin, Santiago

    2006-02-15

    Purpose. To compare the clinical outcome of needle aspiration versus percutaneous catheter drainage of sterile fluid collections in patients with acute pancreatitis. Methods. We reviewed the clinical and imaging data of patients with acute pancreatic fluid collections from 1998 to 2003. Referral for fluid sampling was based on elevated white blood cell count and fevers. Those patients with culture-negative drainages or needle aspirations were included in the study. Fifteen patients had aspiration of 10-20 ml fluid only (group A) and 22 patients had catheter placement for chronic evacuation of fluid (group C). We excluded patients with grossly purulent collections andmore » chronic pseudocysts. We also recorded the number of sinograms and catheter changes and duration of catheter drainage. The CT severity index, Ranson scores, and maximum diameter of abdominal fluid collections were calculated for all patients at presentation. The total length of hospital stay (LOS), length of hospital stay after the drainage or aspiration procedure (LOS-P), and conversions to percutaneous and/or surgical drainage were recorded as well as survival. Results. The CT severity index and acute Ransom scores were not different between the two groups (p = 0.15 and p = 0.6, respectively). When 3 crossover patients from group A to group C were accounted for, the duration of hospitalization did not differ significantly, with a mean LOS and LOS-P of 33.8 days and 27.9 days in group A and 41.5 days and 27.6 days in group C, respectively (p = 0.57 and 0.98, respectively). The 60-day mortality was 2 of 15 (13%) in group A and 2 of 22 (9.1%) in group C. Kaplan-Meier survival curves for the two groups were not significantly different (p 0.3). Surgical or percutaneous conversions occurred significantly more often in group A (7/15, 47%) than surgical conversions in group C (4/22, 18%) (p 0.03). Patients undergoing catheter drainage required an average of 2.2 sinograms/tube changes and kept catheters in for an average of 52 days. Aspirates turned culture-positive in 13 of 22 patients (59%) who had chronic catheterization. In group A, 3 of the 7 patients converted to percutaneous or surgical drainage had infected fluid at the time of conversion (total positive culture rate in group A 3/15 or 20%). Conclusions. There is no apparent clinical benefit for catheter drainage of sterile fluid collections arising in acute pancreatitis as the length of hospital stay and mortality were similar between patients undergoing aspiration versus catheter drainage. However, almost half of patients treated with simple aspiration will require surgical or percutaneous drainage at some point. Disadvantages of chronic catheter drainage include a greater than 50% rate of bacterial colonization and the need for multiple sinograms and tube changes over an average duration of about 2 months.« less

  20. Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods

    PubMed Central

    Tadic, Mario; Stoos-Veic, Tajana; Kusec, Rajko

    2014-01-01

    The role of endoscopic ultrasound (EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration (FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA (EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition (needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy. PMID:25339816

  1. The Clinical Usefulness of Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy for Rectal and Perirectal Lesions

    PubMed Central

    Soh, Jae Seung; Lee, Ho-Su; Lee, Seohyun; Bae, Jungho; Lee, Hyo Jeong; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho

    2015-01-01

    Background/Aims Endoscopic ultrasound-guided fine needle aspiration and/or biopsy (EUS-FNA/B) have been used to diagnose subepithelial tumors (SETs) and extraluminal lesions in the gastrointestinal tract. Our group previously reported the usefulness of EUS-FNA/B for rectal and perirectal lesions. This study reports our expanded experience with EUS-FNA/B for rectal and perirectal lesions in terms of diagnostic accuracy and safety. We also included our new experience with EUS-FNB using the recently introduced ProCore needle. Methods From April 2009 to March 2014, EUS-FNA/B for rectal and perirectal lesions was performed in 30 consecutive patients. We evaluated EUS-FNA/B performance by comparing histological diagnoses with final results. We also investigated factors affecting diagnostic accuracy. Results Among 10 patients with SETs, EUS-FNA/B specimen results revealed a gastrointestinal stromal tumor in 4 patients and malignant lymphoma in 1 patient. The diagnostic accuracy of EUS-FNA/B was 50% for SETs (5/10). Among 20 patients with non-SET lesions, 8 patients were diagnosed with malignant disease and 7 were diagnosed with benign disease based on both EUS-FNA/B and the final results. The diagnostic accuracy of EUS-FNA/B for non-SET lesions was 75% (15/20). The size of lesions was the only factor related to diagnostic accuracy (P=0.027). Two complications of mild fever and asymptomatic pneumoperitoneum occurred after EUS-FNA/B. Conclusions The overall diagnostic accuracy of EUS-FNA/B for rectal and perirectal lesions was 67% (20/30). EUS-FNA/B is a clinically useful method for cytological and histological diagnoses of rectal and perirectal lesions. PMID:25931998

  2. Sacroiliac tuberculosis – A neglected differential in refractory low back pain – Our series of 35 patients

    PubMed Central

    Prakash, Jatin

    2014-01-01

    Introduction Osteo-articular tuberculosis accounts for 1–3% of which 5–8% involves sacro-illiac joint. Isolated sacroiliac involvement is very rare. It usually presents as vague back pain. Plain radiographs are often inconclusive. Due to rarity of lesion, vague symptoms and non-conclusive X-rays the diagnosis is further delayed. We present a series of 35 patients presented with sacroiliac tuberculosis. Methods 35 patients were diagnosed of sacroiliac tuberculosis from January 2008 to December 2011. After a thorough history and clinical examination, patients were taken up for X-rays and MRI scans. Ultrasound guided needle aspiration was done from suspected area. After histological confirmation of the diagnosis, patients were treated with anti tubercular therapy. Results Persistent low back pain and difficulty with walking were noted in all patients. There were 21 males (60%) and 14 females and the age ranged from 22 to 55 years (mean: 27 years). Most of the patients (91.4%) had unilateral disease (32 patients). Results of conservative management were good. 21 (60%) of our patients achieved bony ankylosis at the end of study. 9 patients did not respond to conservative management where surgical debridement was done. 4 of these cases had MDR tuberculosis. Conclusion Sacroiliac tuberculosis must be kept as a differential in all refractory low back pain particularly in endemic areas. MRI is very helpful in early diagnosis of disease. In the early stages of the infection aspiration using a closed needle biopsy is recommended. An open biopsy is essential when the aspirate yields no growth. Open debridement should be done in those not responding to conservative management. PMID:25983488

  3. Fine needle aspiration cytology of oral and oropharyngeal lesions with an emphasis on the diagnostic utility and pitfalls.

    PubMed

    Gupta, Nalini; Banik, Tarak; Rajwanshi, Arvind; Radotra, Bishan D; Panda, Naresh; Dey, Pranab; Srinivasan, Radhika; Nijhawan, Raje

    2012-01-01

    This study was undertaken to evaluate the diagnostic utility and pitfalls of fine needle aspiration cytology (FNAC) in oral and oropharyngeal lesions. This was a retrospective audit of oral and oropharyngeal lesions diagnosed with FNAC over a period of six years (2005-2010). Oral/oropharyngeal lesions [n=157] comprised 0.35% of the total FNAC load. The age ranged 1-80 years with the male: female ratio being 1.4:1. Aspirates were inadequate in 7% cases. Histopathology was available in 73/157 (46.5%) cases. Palate was the most common site of involvement [n=66] followed by tongue [n=35], buccal mucosa [n=18], floor of the mouth [n=17], tonsil [n=10], alveolus [n=5], retromolar trigone [n=3], and posterior pharyngeal wall [n=3]. Cytodiagnoses were categorized into infective/inflammatory lesions and benign cysts, and benign and malignant tumours. Uncommon lesions included ectopic lingual thyroid and adult rhabdomyoma of tongue, and solitary fibrous tumor (SFT), and leiomyosarcoma in buccal mucosa. A single false-positive case was dense inflammation with squamous cells misinterpreted as squamous cell carcinoma (SCC) on cytology. There were eight false-negative cases mainly due to sampling error. One false-negative case due to interpretation error was in a salivary gland tumor. The sensitivity of FNAC in diagnosing oral/oropharyngeal lesions was 71.4%; specificity was 97.8% with diagnostic accuracy of 87.7%. Salivary gland tumors and squamous cell carcinoma (SCC) are the most common lesions seen in the oral cavity. FNAC proves to be highly effective in diagnosing the spectrum of different lesions in this region. Sampling error is the main cause of false-negative cases in this region.

  4. Topical topic: value of fine needle aspiration biopsy in childhood rhabdomyosarcoma: twenty-six years of experience in Slovenia.

    PubMed

    Pohar-Marinsek, Ziva; Anzic, Jozica; Jereb, Berta

    2002-06-01

    Chemotherapy (Cht) for rhabdomyosarcoma (RMS) given before local treatment can prevent mutilating surgery and high-dose irradiation (RT). Fine needle aspiration biopsy (FNAB) can confirm the diagnosis and neoadjuvant treatment can start without delay. The purpose of our study was to assess the role of FNAB in the management of childhood RMS in Slovenia. A total of 78 children and young adults were included. FNAB provided the pre-treatment diagnosis in 37 and surgical biopsy in 41 patients. In 61 cases recurrent/metastatic disease was aspirated. Cytological diagnoses were compared to the original histological diagnoses. All case histories, cytological and histological material were reviewed and immunocytochemical staining performed when necessary. FNAB provided a correct diagnosis of malignancy in all 37 primary tumours, a specific diagnosis of RMS was given in 29 (78%). With the use of immunocytochemistry during the last 15 years, the accuracy has risen to 87%. FNAB provided the diagnosis of recurrence/metastasis in 57/61 cases. No complications of FNAB were noted. Review of histology reclassified five original diagnoses of RMS into one malignant rhabdoid tumour and four sarcomas NOS. In review of cytology we were able to sub classify 80% of RMS. FNAB is a safe method, which enables us to establish the pre-treatment diagnosis of RMS, and to some extent even its type, without delay. In our study, FNAB successfully replaced surgical biopsy in 87% of RMS patients during the last 15 years. Neoadjuvant Cht was started immediately, surgery was delayed and more conservative. Consequently, the risk for treatment sequelae was considerably reduced. Copyright 2002 Wiley-Liss, Inc.

  5. Pulmonary tularaemia: all that looks like cancer is not necessarily cancer - case report of four consecutive cases.

    PubMed

    Fachinger, Patrick; Tini, Gabrielo Mauro; Grobholz, Rainer; Gambazzi, Franco; Fankhauser, Hans; Irani, Sarosh

    2015-03-26

    Pulmonary tularaemia is a very rare disease with only a small number of cases described in the literature. So far, to our knowledge, there exists no case report of pulmonary tularaemia where PET-CT scans and follow up CT scans are available. We present four consecutive cases of pulmonary tularaemia. All patients suffered from non-specific symptoms. All patients were referred to our institution with strong suspicions of malignancy, particularly lung cancer. Diagnosis of tularaemia was made by typical findings in the aspirate of EBUS guided fine needle aspiration (necrosis, epithelioid cell aggregation) and surgical biopsy respectively, and a positive serology. In three of the four cases, the diagnosis was confirmed by positive PCR results of the tissue. PET-CT scans obtained in all four cases were indistinguishable from lesions typically seen in patients suffering from lung cancer. One of the four patients suffered from recurrence of the disease after antibiotic treatment; also this patient finally recovered after initiation of a second antibiotic regimen. One case became asymptomatic spontaneously, but this patient still received an antibiotic treatment. In one case, a follow up CT scan was unchanged compared to the initial PET-CT scan; in all other cases, the lesions disappeared almost completely. Symptoms of patients suffering from pulmonary tularaemia are non-specific and can be of prolonged character. PET-CT scans in these cases are indistinguishable from lung cancer. The diagnosis can be established when typical findings in EBUS guided fine needle aspirates or surgical biopsies are found in combination with a positive serology. In most cases the lesions disappear in follow up CT scans after clinically successful treatment.

  6. Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, Takaaki, E-mail: t-hasegawa@aichi-cc.jp; Kondo, Chiaki; Sato, Yozo

    PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Twomore » tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.« less

  7. Endoscopic ultrasound in gastroenterology: from diagnosis to therapeutic implications.

    PubMed

    Mekky, Mohamed A; Abbas, Wael A

    2014-06-28

    Since its advent in 1980, the scope of endoscopic ultrasound (EUS) has grown to include a wide range of indications, and it is now being incorporated as an integral part of everyday practice in the field of gastroenterology. Its use is extending from an adjuvant imaging aid to utilization as a therapeutic tool for various gastrointestinal disorders. EUS was first used to visualize remote organs, such as the pancreas and abdominal lymph nodes. When fine needle aspiration was introduced, the indications for EUS expanded to include tissue sampling for diagnostic purposes. At the same time, the needle can be used to convey a potential therapy to the internal organs, allowing access to remote sites. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in the field of gastroenterology.

  8. Liesegang-Like Rings in Lactational Changes in the Breast

    PubMed Central

    Islam, Mohd T.; Ou, Joyce J.; Hansen, Katrine; Simon, Rochelle A.; Quddus, M. Ruhul

    2012-01-01

    Liesagang-like rings (LR) are periodic structures with equally spaced radial striations formed by a process that involves diffusion, nucleation, flocculation or precipitation, and supersaturation. Being more common in vitro, on rare occasions also reported in vivo in association with inflammatory or cystic lesions and confused with parasites or calcification on needle aspirates. The current paper documents that LRs may be seen in noncystic and noninflammatory changes of the breast. PMID:23094171

  9. Role of endoscopic ultrasonography in the diagnosis of acute and chronic pancreatitis.

    PubMed

    Stevens, Tyler

    2013-10-01

    Endoscopic ultrasonography (EUS) can be a useful tool for detecting underlying causes of acute pancreatitis and establishing the severity of fibrosis in chronic pancreatitis. Ancillary techniques include fine needle aspiration and core biopsy, bile collection for crystal analysis, pancreatic function testing, and celiac plexus block. This review focuses on the role of EUS in the diagnosis of acute and chronic pancreatitis. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Percutaneous aspiration of fluid for management of peritonitis in space

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, A. W.; Nicolaou, S.; Campbell, M. R.; Sargsyan, A. E.; Dulchavsky, S. A.; Melton, S.; Beck, G.; Dawson, D. L.; Billica, R. D.; Johnston, S. L.; hide

    2002-01-01

    BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. Hypothesis: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.

  11. Alzheimer's disease cerebrospinal fluid biomarkers are not influenced by gravity drip or aspiration extraction methodology.

    PubMed

    Rembach, Alan; Evered, Lisbeth A; Li, Qiao-Xin; Nash, Tabitha; Vidaurre, Lesley; Fowler, Christopher J; Pertile, Kelly K; Rumble, Rebecca L; Trounson, Brett O; Maher, Sarah; Mooney, Francis; Farrow, Maree; Taddei, Kevin; Rainey-Smith, Stephanie; Laws, Simon M; Macaulay, S Lance; Wilson, William; Darby, David G; Martins, Ralph N; Ames, David; Collins, Steven; Silbert, Brendan; Masters, Colin L; Doecke, James D

    2015-11-19

    Cerebrospinal fluid (CSF) biomarkers, although of established utility in the diagnostic evaluation of Alzheimer's disease (AD), are known to be sensitive to variation based on pre-analytical sample processing. We assessed whether gravity droplet collection versus syringe aspiration was another factor influencing CSF biomarker analyte concentrations and reproducibility. Standardized lumbar puncture using small calibre atraumatic spinal needles and CSF collection using gravity fed collection followed by syringe aspirated extraction was performed in a sample of elderly individuals participating in a large long-term observational research trial. Analyte assay concentrations were compared. For the 44 total paired samples of gravity collection and aspiration, reproducibility was high for biomarker CSF analyte assay concentrations (concordance correlation [95%CI]: beta-amyloid1-42 (Aβ42) 0.83 [0.71 - 0.90]), t-tau 0.99 [0.98 - 0.99], and phosphorylated tau (p-tau) 0.82 [95 % CI 0.71 - 0.89]) and Bonferroni corrected paired sample t-tests showed no significant differences (group means (SD): Aβ42 366.5 (86.8) vs 354.3 (82.6), p = 0.10; t-tau 83.9 (46.6) vs 84.7 (47.4) p = 0.49; p-tau 43.5 (22.8) vs 40.0 (17.7), p = 0.05). The mean duration of collection was 10.9 minutes for gravity collection and <1 minute for aspiration. Our results demonstrate that aspiration of CSF is comparable to gravity droplet collection for AD biomarker analyses but could considerably accelerate throughput and improve the procedural tolerability for assessment of CSF biomarkers.

  12. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    PubMed

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  13. Use of Fine Needle Aspirate from Peripheral Nerves of Pure-neural Leprosy for Cytology and Polymerase Chain Reaction to Confirm the Diagnosis: A Follow-up Study of 4 Years.

    PubMed

    De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip

    2017-01-01

    Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL.

  14. OK-432 sclerotherapy of cervical chylous lymphocele after neck dissection.

    PubMed

    Roh, Jong-Lyel; Park, Chan Il

    2008-06-01

    Postoperative cervical chylous lymphoceles are extremely rare circumscribed collections of lymph which are usually treated by drainage or surgical exploration, but rarely by sclerotherapy. We investigated the efficacy of OK-432 (Picibanil, Chungai Pharmaceutical Co., Tokyo, Japan) sclerotherapy in the treatment of cervical lymphocele after neck dissection. Four patients with postoperative lymphocele who could not be cured by repeated percutaneous needle aspiration and pressure dressing were treated with intralesional injection of 0.1-0.2 mg OK-432 after aspiration of fluid. The aspirated fluid was assessed biochemically and cytologically, and regular palpation and ultrasonography/computed tomography were used to evaluate outcomes and recurrences. Two patients with chyle leak during neck dissection had lymphoceles in the left supraclavicular region 3 weeks later. The other two patients had lymphoceles on the right neck 9 and 12 months, respectively, after neck dissection. All aspirated fluids were chylous in origin without tumor cells. OK-432 sclerotherapy scored all four lesions with no major complications except for fever and local pain for several days. No lymphocele recurrences or metastatic cancers were observed in any patient for >1 year after sclerotherapy. Intralesional injection of OK-432 may be a safe and effective alternative to surgical exploration in the treatment of cervical lymphocele after neck dissection.

  15. Improvement of the Mair scoring system using structural equations modeling for classifying the diagnostic adequacy of cytology material from thyroid lesions.

    PubMed

    Kulkarni, H R; Kamal, M M; Arjune, D G

    1999-12-01

    The scoring system developed by Mair et al. (Acta Cytol 1989;33:809-813) is frequently used to grade the quality of cytology smears. Using a one-factor analytic structural equations model, we demonstrate that the errors in measurement of the parameters used in the Mair scoring system are highly and significantly correlated. We recommend the use of either a multiplicative scoring system, using linear scores, or an additive scoring system, using exponential scores, to correct for the correlated errors. We suggest that the 0, 1, and 2 points used in the Mair scoring system be replaced by 1, 2, and 4, respectively. Using data on fine-needle biopsies of 200 thyroid lesions by both fine-needle aspiration (FNA) and fine-needle capillary sampling (FNC), we demonstrate that our modification of the Mair scoring system is more sensitive and more consistent with the structural equations model. Therefore, we recommend that the modified Mair scoring system be used for classifying the diagnostic adequacy of cytology smears. Diagn. Cytopathol. 1999;21:387-393. Copyright 1999 Wiley-Liss, Inc.

  16. Endoscopic Ultrasound-guided Specimen Collection and Evaluation Techniques Affect Diagnostic Accuracy.

    PubMed

    Bang, Ji Young; Navaneethan, Udayakumar; Hasan, Muhammad K; Hawes, Robert; Varadarajulu, Shyam

    2018-03-11

    Outcomes of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) evaluation vary with technique, needles, and methods of specimen evaluation. We performed a direct comparison of diagnostic yields of EUS-FNA samples collected using different gauge needles (22- vs 25-gauge), with or without suction. We performed a randomized controlled study of 352 patients with suspected pancreatic masses, referred for EUS-FNA at a tertiary referral center. Patients were randomly assigned to 22-gauge needles with or without suction or 25-gauge needles with or without suction. Specimens were evaluated offsite by cell block and rapid onsite cytologic evaluation (ROSE). Final diagnoses were made based on histologic analyses or 12-month follow-up evaluations. The primary outcome was diagnostic adequacy of cell blocks. Secondary outcomes were operating characteristics of ROSE and EUS-FNA, number of passes required for accurate onsite diagnosis, and amount of blood in specimens. The final diagnoses were malignancy (81.5% of patients) and benign disease (17.0% of patients); 1.4% of patients were lost during follow up. Cell block, ROSE, and EUS-FNA led to diagnostic accuracies of 71.9%, 95.5%, and 96.6%, respectively. A 22-gauge needle with suction was associated with more passes for adequate onsite diagnosis (P = .003) and specimens contained more blood (P = .01). Diagnostic accuracy of specimens collected by transduodenal EUS-FNA was lower with 22-gauge needles with suction compared to other techniques (P = .004). In a randomized trial of patients undergoing EUS-FNA for pancreatic masses, samples collected with 22-gauge vs 25-gauge needles performed equally well for offsite specimen evaluation. Use of suction appears to increase number of passes needed and specimen bloodiness. Specimen collection techniques should be individualized based on method of evaluation. ClinicalTrials.gov no: NCT02424838. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  17. Aspiration in injections: should we continue or abandon the practice?

    PubMed Central

    Sepah, Yasir; Samad, Lubna; Altaf, Arshad; Halim, Muhammad Sohail; Rajagopalan, Nithya; Javed Khan, Aamir

    2017-01-01

    Aspiration during any kind of injection is meant to ensure that the needle tip is at the desired location during this blind procedure. While aspiration appears to be a simple procedure, it has generated a lot of controversy concerning the perceived benefits and indications. Advocates and opponents of aspiration both make logically sound claims. However, due to scarcity of available data, there is no evidence that this procedure is truly beneficial or unwarranted. Keeping in view the huge number of injections given worldwide, it is important that we draw attention to key questions regarding aspiration that, up till now, remain unanswered. In this review, we have attempted to gather and present literature on aspiration both from published and non-published sources in order to provide not only an exhaustive review of the subject, but also a starting point for further studies on more specific areas requiring clarification. A literature review was conducted using the US National Institute of Health’s PubMed service (including Medline), Google Scholar and Scopus. Guidelines provided by the World Health Organization, Safe Injection Global Network, International Council of Nursing, Center for Disease Control, US Federal Drug Agency, UK National Health Services, British Medical Association, Europe Nursing and Midwifery Council, Public Health Agency Canada, Pakistan Medical Association and International Organization of Standardization recommendations 7886 parts 1-4 for sterile hypodermics were reviewed for relevant information. In addition, curricula of several medical/nursing schools from India, Nigeria and Pakistan, the US pharmacopeia Data from the WHO Program for International Drug Monitoring network in regard to adverse events as a result of not aspirating prior to injection delivery were reviewed. Curricula of selected major medical/nursing schools in India, Nigeria and Pakistan, national therapeutic formularies, product inserts of most commonly used drugs and other possible sources of information regarding aspiration and injections were consulted as well. PMID:28344770

  18. Glass Particulate Contamination from Medications Aspirated from Glass Ampules: Comparison of Filtered Versus Non-Filtered Needles

    DTIC Science & Technology

    1994-09-01

    with giant cells found in the spleen and lungs. A second experiment 3 (Brewer & Dunning, 1947) was conducted where 1,089 mice were injected...crystals, or starch. They conducted experiments where rabbits received I I.V. normal saline via the ear vein. Each rabbit received a different volume...conducted a similar experiment examining the incidence of drug contamination with particles from the external surface of glass ampules. Methylene blue

  19. Diagnostic Efficacy of Cell Block Immunohistochemistry, Smear Cytology, and Liquid-Based Cytology in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions: A Single-Institution Experience

    PubMed Central

    Qin, Shan-yu; Zhou, You; Li, Ping; Jiang, Hai-xing

    2014-01-01

    Background The diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology varies widely depending on the treatment method of the specimens. The present study aimed to evaluate the diagnostic efficacy of cell block (CB) immunohistochemistry, smear cytology (SC), and liquid-based cytology (LBC) in patients with pancreatic lesions without consulting an on-site cytopathologist. Methods This study prospectively enrolled 72 patients with pancreatic lesions. The EUS-FNA specimens were examined by SC, LBC, and CB immunohistochemistry. The diagnostic efficacy of the 3 methods was then compared. Patients’ final diagnosis was confirmed by surgical resection specimens, diagnostic imaging, and clinical follow-up. Results Our results included 60 malignant and 12 benign pancreatic lesions. The diagnostic sensitivity (90%), negative predictive value (66.7%), and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 30.0%, and 75.0%, respectively) and LBC (73.3%, 31.6%, and 77.8%, respectively) (all P<0.05). The combination of CB and SC, or CB and LBC, did not significantly increase the efficacy compared to CB immunohistochemistry alone. Conclusion Our findings suggest that in the absence of an on-site cytopathologist, CB immunohistochemistry on EUS-FNA specimens offers a higher diagnostic efficacy in patients with pancreatic lesions than does SC and LBC. PMID:25259861

  20. Management of cystic or predominantly cystic thyroid nodules: the role of ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Bellantone, Rocco; Lombardi, Celestino Pio; Raffaelli, Marco; Traini, Emanuela; De Crea, Carmela; Rossi, Esther Diana; Fadda, Guido

    2004-01-01

    Conventional fine-needle aspiration biopsy (FNAB) for cystic thyroid nodules (CTNs) has a high rate of nondiagnostic and false-negative results. Ultrasound-guided FNAB (UG-FNAB) permits direct sampling of the wall and/or the solid portion of CTNs, increasing the possibility of a representative sample. In this study we evaluated the role of UG-FNAB in CTNs management. Five-hundred-seventy-five UG-FNAB of CTNs were performed. Thyroidectomy was carried out in 119 of these cases. The medical records of these 119 patients were reviewed and form the basis of this report. The nondiagnostic smear rate was 9.2%. Cytological diagnosis was benign nodule in 42 cases, predominantly follicular lesion in 50 cases, and suspicious or malignant lesion in 16 cases. The final pathology revealed a benign nodule in 98 cases (82.4%) and a carcinoma in 21 (17.6%). The overall accuracy of UG-FNAB was 88.0%. No significant differences were found in age, sex, lesion size, or echographic pattern (p = NS) comparing patients with benign CTNs to patients with malignant CTNs. UG-FNAB has a low rate of nondiagnostic smears and a high overall accuracy in CTNs. All CTNs should undergo UG-FNAB to select patients for surgery, since the malignancy rate is not negligible and no clinical parameter can reliably predict it.

  1. Endoscopic ultrasound guided brush/fine-needle aspiration cytology: A 15-month study.

    PubMed

    Tummidi, Santosh; Kothari, Kanchan; Sathe, Pragati; Agnihotri, Mona; Fernandes, Gwendolyn; Naik, Leena; Jain, Aleena; Chaturvedi, Rachana

    2018-06-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become increasingly popular for the diagnosis and staging of gastrointestinal diseases and peri-gastrointestinal lesions. The application of FNA/Brush has dramatically expanded the clinical utility of EUS. To evaluate the diagnostic accuracy, study the spectrum of lesions encountered in EUS-FNAC/brush cytology of gastrointestinal and peri-gastrointestinal lesions. Total of 124 patients during the period from August 2015 to November 2016 was included in the study. Routine staining was done. A total of 124 cases were studied with 86% (107 cases) being satisfactory for evaluation. M:F ratio was 1:1.03, mean age of 50.5 years. The most common site was common bile duct (CBD) (37%) followed by lymph node (21%), pancreas (17.7%), esophagus (17%), stomach (3.5%), liver (1.8%), gallbladder (1%), and spleen (1%). In total, 53.4% lesions were benign, in 6.5% atypical cells were seen, 12.1% were suspicious for malignancy, and 28% cases were positive for malignancy. Follow-up was available in 102 cases with cyto-histopathological concordance rate of 90%. EUS-FNA/Brush is a reliable, sensitive, specific and minimally invasive way to establish a diagnosis. It can be utilized as a pre-operative procedure for the management of many intra-abdominal lesions and prevent unnecessary invasive procedures. © 2018 Wiley Periodicals, Inc.

  2. Fine-needle aspiration study of cystic papillary thyroid carcinoma: Rare cytological findings

    PubMed Central

    Mokhtari, Maral; Kumar, Perikala Vijayananda; Hayati, Kamran

    2016-01-01

    Background: Cystic papillary thyroid carcinoma (CPTC) is a variant of papillary carcinoma that has many mimickers in cytological grounds. Aim: To study the cytomorphologic features of CPTC and compare them to those of other cystic thyroid lesions using fine-needle aspiration cytology (FNAC). We also aimed to identify the cytomorphologic features that distinguish CPTC from other cystic thyroid lesions. Materials and Methods: Seventy-three cases of CPTC were included in the study. The cytomorphologic features of these cases were analyzed. The FNA smears of other thyroid lesions with cystic changes (300 colloid goiters, 290 adenomatoid nodules, 11 follicular neoplasms, and 9 hurtle cell neoplasm) were also studied. Results: The smears in CPTC revealed isolated follicular cells, small groups of cells with scalloped margins, cell swirls, small clusters with a cartwheel pattern, papillary clusters, intranuclear inclusions, nuclear grooves, sticky colloid, intracellular colloids, psammoma bodies, multinucleated giant cells, and foamy and hemosiderin laden macrophages. Small groups of cells with scalloped borders, cellular swirls, and small clusters with a cartwheel pattern were seen in CPTC, but not in other cystic lesions. Interestingly, mesothelial-like cells and hemophagocytic cells were seen in five and three cases of CPTC, respectively, but not in other cystic lesions. Conclusion: Mesothelial-like cells and hemophagocytic cells were observed in five and three cases of CPTC, respectively. Similar finding have not been previously reported in the literature. PMID:27756982

  3. Breast fine-needle aspiration malondialdehyde deoxyguanosine adduct in breast cancer

    PubMed Central

    Peluso, Marco; Munnia, Armelle; Risso, Gabriella G.; Catarzi, Sandra; Piro, Sara; Ceppi, Marcello; Giese, Roger W.; Brancato, Beniamino

    2012-01-01

    This study has analysed the generation of 3-(2-deoxy-β-D-erythro-pentafuranosyl) pyrimido [1,2-α] purin-10 (3H)-one deoxyguanosine adduct [M1dG], a biomarker of oxidative stress and lipid peroxidation, in breast fine-needle aspirate samples of 22 patients with breast cancer, at different clinical stages, in respect to 13 controls. The multivariate analysis show that M1dG adduct was higher in cases than in controls (Mean Ratio (MR) = 5.26, 95% CI = 3.16–8.77). Increased M1dG was observed in women with a tumour grade 3 and a pathological diameter 2 (MR = 7.61, 95% CI 3.91–14.80 and MR = 5.75, 95% CI = 3.13–10.59, respectively). A trend with increasing tumour grade and pathological diameter was present (MR = 1.98, 95% CI = 1.57–2.50 and MR = 2.44, 95% CI = 1.71–3.48, respectively). Not significant effects of age and smoking habit were found (MR = 1.58, 95% CI = 0.92–2.72 and MR = 1.68, 95% CI 0.88–3.20, respectively). An increment over the background frequency of M1dG can contribute to breast cancer development. Increasing severity of breast tumour can influence DNA damage level. PMID:21250785

  4. ThinPrep versus conventional smear cytologic preparations in the analysis of thyroid fine-needle aspiration specimens.

    PubMed

    Biscotti, C V; Hollow, J A; Toddy, S M; Easley, K A

    1995-08-01

    Paired fine-needle aspiration specimens were analyzed from 41 surgically resected thyroid nodules, to compare diagnostic accuracy, amount (absent, mild, moderate, or marked) and pattern (diffuse, droplets, or both) of colloid, nuclear detail (poor, satisfactory, or excellent) and cytoplasmic detail (intact or disrupted) in ThinPrep (TP) (Cytyc, Marlborough, MA) versus conventional smear (CS) cytologic preparations. The 41 surgical specimens included 25 colloid nodules, 6 papillary carcinomas, 4 follicular adenomas, 2 minimally invasive (encapsulated) follicular carcinomas, 3 Hashimoto's thyroiditis, and 1 Grave's disease. Both techniques identified seven of the eight carcinomas with the minimally invasive follicular carcinomas categorized as hypercellular follicular nodule, possibly malignant (HCFN). One papillary carcinoma was classified as a HCFN by both TP and CS techniques. The four follicular adenomas were classified as HCFN based on the TP slides. One oxyphilic follicular adenoma, associated with focal lymphocytic thyroiditis, was misinterpreted as Hashimoto's thyroiditis on a conventional smear. Three colloid nodules were interpreted as HCFN based on the TP slides. Two of these were similarly classified based on the conventional smear. ThinPrep slides contained less colloid and the colloid occurred as droplets rather than a diffuse pattern. TP slides had better nuclear detail but more often disrupted cytoplasm. In conclusion, the TP process does alter some cellular features; however, we experienced similar diagnostic accuracy with the TP and conventional smear preparations.

  5. [Fine-needle aspiration (FNA) of the thyroid gland : Analysis of discrepancies between cytological and histological diagnoses].

    PubMed

    Dalquen, P; Rashed, B; Hinsch, A; Issa, R; Clauditz, T; Luebke, A; Lüttges, J; Saeger, W; Bohuslavizki, K H

    2016-09-01

    Diagnostic problems of thyroid cytology are frequently discussed, but relevance and causes of discrepant cytological and histological diagnoses are rarely studied in detail. Investigation of causes and relevance of discrepant diagnoses. The analysis includes 297 patients who had thyroid resection after prior fine needle aspiration (FNA) and is based on the cytological and histological reports. In special cases, cytological and histological specimens were re-examined. Malignant tumors were found in 45 patients (15.1 %). In 5 patients the cytological diagnosis was "false negative". Three of these 5 tumors were papillary carcinomas (PTC) of ≤10 mm, one an obviously nonmalignant papillary proliferation of the thyroidal epithelium and one a malignant lymphoma complicating autoimmune thyreoiditis (AIT). In 11 of the 35 patients with a FNA diagnosis "suspicious of malignancy" or "malignant," 1 AIT, 4 goiter nodules, and 6 adenomas were diagnosed histologically. However, since distinct nuclear atypia was found in three of five false positive diagnoses, there still remains doubt in their benignity. Carcinomas of ≤10 mm incidentally detected in the resected thyroid tissue may not be relevant to the patient and do not reduce the high negative predictive value of FNA. The final diagnosis on the resected tissue should include the cytological findings. Discrepant findings should be commented in the report to the clinician.

  6. The use of light-emitting diode fluorescence to diagnose mycobacterial lymphadenitis in fine-needle aspirates from children

    PubMed Central

    van Wyk, A. C.; Marais, B. J.; Warren, R. M.; van Wyk, S. S.; Wright, C. A.

    2011-01-01

    SUMMARY BACKGROUND Fine-needle aspiration biopsy (FNAB) is a simple, safe and effective method for investigating suspected mycobacterial lymphadenitis in children. Fluorescence microscopy can provide rapid mycobacterial confirmation. Light-emitting diodes (LEDs) provide a cheap and robust excitation light source, making fluorescence microscopy feasible in resource-limited settings. OBJECTIVE To compare the diagnostic performance of LED fluorescence microscopy on Papanicolaou (PAP) stained smears with the conventional mercury vapour lamp (MVL). METHODS FNAB smears routinely collected from palpable lymph nodes in children with suspected mycobacterial disease were PAP-stained and evaluated by two independent microscopists using different excitatory light sources (MVL and LED). Mycobacterial culture results provided the reference standard. A manually rechargeable battery-powered LED power source was evaluated in a random subset. RESULTS We evaluated 182 FNAB smears from 121 children (median age 31 months, interquartile range 10–67). Mycobacterial cultures were positive in 84 of 121 (69%) children. The mean sensitivity with LED (mains-powered), LED (rechargeable battery-powered) and MVL was respectively 48.2%, 50.0% and 51.8% (specificity 78.4%, 86.7% and 78.4%). Inter-observer variation was similar for LED and MVL (κ = 0.5). CONCLUSION LED fluorescence microscopy provides a reliable alternative to conventional methods and has many favourable attributes that would facilitate improved, decentralised diagnostic services. PMID:21276297

  7. [Diagnostic accuracy of fine needle aspiration cytology in parotid tumours].

    PubMed

    Zerpa Zerpa, Vanessa; Cuesta Gonzáles, Maria Teresa; Agostini Porras, Gabriela; Marcano Acuña, Martin; Estellés Ferriol, Enrique; Dalmau Galofre, José

    2014-01-01

    Fine needle aspiration cytology (FNAC) is a globally accepted technique in the preoperative evaluations of head and neck tumours; however, the effectiveness in the interpretation of salivary glands neoplastic lesions is still controversial. The objective of this study consisted of assessing the efficacy of FNAC in preoperative diagnosis of parotid tumours. This retrospective study was conducted using 93 patient samples with parotid gland tumoral pathology, treated at the Otorhinolaryngology Department in our institution during the 2007-2011 period. Preoperative FNAC was employed and the patients subsequently submitted to surgical excision with histopathological diagnosis of the specimen. Cytology results were classified as negative for malignancy, positive for malignancy or insufficient sample, and later compared with the definitive histological diagnosis. The mean age of the studied sample was 52.9 years (range: 11 to 88 years); 55.9% were men. The FNAC showed significant sensitivity of 57.1%, with a specificity of 95.1%, for detecting malignancy in parotid gland tumours. The positive and negative predictive values for malignancy were 50 and 96.3%, respectively. FNAC is considered a simple test but of limited use for diagnostic guidance in tumour pathology of the parotid gland in our environment, mainly because of its low sensitivity. However, the high specificity and high negative predictive value of FNAC makes it a more accurate test in benign or negative result cases. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  8. [Hepatic fine needle aspiration biopsy. Experience in the study of hepatic masses at the Salvador Zubiran National Institute of Nutrition].

    PubMed

    Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L

    1994-01-01

    The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.

  9. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    PubMed

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  10. Ultrasound-Guided Transcutaneous Needle Biopsy of the Base of the Tongue and Floor of the Mouth From a Submental Approach.

    PubMed

    Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M

    2016-05-01

    Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.

  11. Detection of residual disease after neoadjuvant chemoradiotherapy for oesophageal cancer (preSANO): a prospective multicentre, diagnostic cohort study.

    PubMed

    Noordman, Bo Jan; Spaander, Manon C W; Valkema, Roelf; Wijnhoven, Bas P L; van Berge Henegouwen, Mark I; Shapiro, Joël; Biermann, Katharina; van der Gaast, Ate; van Hillegersberg, Richard; Hulshof, Maarten C C M; Krishnadath, Kausilia K; Lagarde, Sjoerd M; Nieuwenhuijzen, Grard A P; Oostenbrug, Liekele E; Siersema, Peter D; Schoon, Erik J; Sosef, Meindert N; Steyerberg, Ewout W; van Lanschot, J Jan B

    2018-05-31

    After neoadjuvant chemoradiotherapy for oesophageal cancer, roughly half of the patients with squamous cell carcinoma and a quarter of those with adenocarcinoma have a pathological complete response of the primary tumour before surgery. Thus, the necessity of standard oesophagectomy after neoadjuvant chemoradiotherapy should be reconsidered for patients who respond sufficiently to neoadjuvant treatment. In this study, we aimed to establish the accuracy of detection of residual disease after neoadjuvant chemoradiotherapy with different diagnostic approaches, and the optimal combination of diagnostic techniques for clinical response evaluations. The preSANO trial was a prospective, multicentre, diagnostic cohort study at six centres in the Netherlands. Eligible patients were aged 18 years or older, had histologically proven, resectable, squamous cell carcinoma or adenocarcinoma of the oesophagus or oesophagogastric junction, and were eligible for potential curative therapy with neoadjuvant chemoradiotherapy (five weekly cycles of carboplatin [area under the curve 2 mg/mL per min] plus paclitaxel [50 mg/m 2 of body-surface area] combined with 41·4 Gy radiotherapy in 23 fractions) followed by oesophagectomy. 4-6 weeks after completion of neoadjuvant chemoradiotherapy, patients had oesophagogastroduodenoscopy with biopsies and endoscopic ultrasonography with measurement of maximum tumour thickness. Patients with histologically proven locoregional residual disease or no-pass during endoscopy and without distant metastases underwent immediate surgical resection. In the remaining patients a second clinical response evaluation was done (PET-CT, oesophagogastroduodenoscopy with biopsies, endoscopic ultrasonography with measurement of maximum tumour thickness, and fine-needle aspiration of suspicious lymph nodes), followed by surgery 12-14 weeks after completion of neoadjuvant chemoradiotherapy. The primary endpoint was the correlation between clinical response during clinical response evaluations and the final pathological response in resection specimens, as shown by the proportion of tumour regression grade (TRG) 3 or 4 (>10% residual carcinoma in the resection specimen) residual tumours that was missed during clinical response evaluations. This study was registered with the Netherlands Trial Register (NTR4834), and has been completed. Between July 22, 2013, and Dec 28, 2016, 219 patients were included, 207 of whom were included in the analyses. Eight of 26 TRG3 or TRG4 tumours (31% [95% CI 17-50]) were missed by endoscopy with regular biopsies and fine-needle aspiration. Four of 41 TRG3 or TRG4 tumours (10% [95% CI 4-23]) were missed with bite-on-bite biopsies and fine-needle aspiration. Endoscopic ultrasonography with maximum tumour thickness measurement missed TRG3 or TRG4 residual tumours in 11 of 39 patients (28% [95% CI 17-44]). PET-CT missed six of 41 TRG3 or TRG4 tumours (15% [95% CI 7-28]). PET-CT detected interval distant histologically proven metastases in 18 (9%) of 190 patients (one squamous cell carcinoma, 17 adenocarcinomas). After neoadjuvant chemoradiotherapy for oesophageal cancer, clinical response evaluation with endoscopic ultrasonography, bite-on-bite biopsies, and fine-needle aspiration of suspicious lymph nodes was adequate for detection of locoregional residual disease, with PET-CT for detection of interval metastases. Active surveillance with this combination of diagnostic modalities is now being assessed in a phase 3 randomised controlled trial (SANO trial; Netherlands Trial Register NTR6803). Dutch Cancer Society. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Primary Pulmonary Mucinous Cystadenocarcinoma: A Case Report

    PubMed Central

    Efstathiou, Andreas; Asteriou, Christos; Barbetakis, Nikolaos; Miliaras, Dimosthenis; Kleontas, Athanassios; Karvelas, Christos; Lalountas, Miltiadis

    2011-01-01

    Primary pulmonary mucinous cystadenocarcinoma (PMCAC) is an extremely rare cystic neoplasm. A case of a 56-year-old male with a cystic lesion of the right lower lobe is described. Preoperative fine needle aspiration cytology and bronchoscopy were inconclusive. The patient underwent a formal right lower lobectomy and mediastinal lymph node dissection. Diagnosis was established intraoperatively. The biological behavior of primary PMCAC is unknown. Therefore, careful long-term follow-up is considered necessary because of lack of experience globally. PMID:21541179

  13. Incorporating Functional Imaging Information into rpFNA Analysis for Breast Cancer Detection in High Risk Women

    DTIC Science & Technology

    2010-03-01

    TITLE: INCORPORATING FUNCTIONAL IMAGING INFORMATION TO rpFNA ANALYSIS FOR BREAST CANCER DETECTION IN HIGH-RISK WOMEN PRINCIPAL INVESTIGATOR...Imaging Information into rpFNA 5a. CONTRACT NUMBER Analysis for Breast Cancer Detection in High Risk Women 5b. GRANT NUMBER W81XWH-08-1-0192 5c...results of random periareolar fine needle aspiration (rpFNA) in women at high risk for breast cancer. In this second year of work, efforts have been

  14. Nodular Graves' disease with medullary thyroid cancer.

    PubMed

    Khan, Shoukat Hussain; Rather, Tanveer Ahmed; Makhdoomi, Rumana; Malik, Dharmender

    2015-01-01

    Co-existence of thyroid nodules with Graves' disease has been reported in various studies. 10-15% of such nodules harbor thyroid cancer with papillary thyroid cancer being the commonest. Medullary thyroid cancer (MTC) in nodules associated with Graves' disease is rare. On literature survey, we came across 11 such cases reported so far. We report a 62-year-old female with Graves' disease who also had a thyroid nodule that on fine-needle aspiration cytology and the subsequent postthyroidectomy histopathological examination was reported to be MTC.

  15. An 111In-Pentetreotide Positive Sclerosing Pneumocytoma.

    PubMed

    Savelli, Giordano; Bnà, Claudio; Zambelli, Claudia; Illuminati, Sonia; Bonello, Luke

    2017-04-01

    A 43-year-old woman had an incidental lung mass identified on shoulder x-ray performed for pain. Contrast-enhanced CT showed a 38-mm mass in the medial segment of the right middle lobe, with features suggestive of carcinoid tumor. A In-pentetreotide scan showed intense uptake; furthermore, fine needle aspiration biopsy yielded neuroendocrine cells confirming the carcinoid hypothesis. However, definitive surgical histology showed a sclerosing pneumocytoma. This could potentially suggest that such rare tumors, with metastatic potential, could respond to somatostatin analogue treatment.

  16. Recurrence after exenteration for canine orbital malignant schwannoma

    PubMed Central

    Kang, Seonmi; Yang, Jungwhan; Lee, Yesran; Pyo, Hyomyeong; Kim, Jaehoon

    2017-01-01

    A 14-year-old Maltese dog presented with progressive exophthalmos and external deviation of the right eye. Ultrasonography revealed the presence of a retrobulbar mass and fine-needle aspiration cytology was performed, which detected a malignant mass. There was no evidence of metastasis on thoracic and abdominal radiography. Computed tomography showed no invasion into the bony orbit and no metastasis to the lung or lymph nodes. Exenteration was performed to remove the mass completely. Malignant peripheral nerve sheath tumor was confirmed by histopathological examination. PMID:27456774

  17. Endoscopic drainage and cystoduodedonstomy in a child with pancreatic pseudocyst.

    PubMed

    Ateş, Ufuk; Küçük, Gönül; Çınar, Kubilay; Bahadır, Berktuğ; Bektaş, Mehmet; Göllü, Gülnur; Bingöl Koloğlu, Meltem

    2017-11-01

    An 11-year-old morbidly obese boy was diagnosed with pancreatic pseudocyst. Following fine needle aspiration, the cyst recurred in 1-month follow-up. Therefore, endoscopic drainage and cystoduodenostomy was performed following endosonography. Control ultrasonography (USG) revealed a completely shrunken cyst. During the 3 years of follow-up, the patient was asymptomatic with no evidence of cyst on computerized tomography scans. Endoscopic drainage and cystoduodenostomy is a minimally invasive, effective, and safe approach in the management of pancreatic pseudocysts in children.

  18. Breast Abscess Mimicking Breast Carcinoma in Male.

    PubMed

    Gochhait, Debasis; Dehuri, Priyadarshini; Umamahesweran, Sandyya; Kamat, Rohan

    2018-01-01

    Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  19. New technique for treating pseudocyst of the auricle.

    PubMed

    Zhu, L X; Wang, X Y

    1990-01-01

    Although pseudocyst of the auricle is a common disease in China, its cause and mechanism are still not clear. Several methods of treatment have been advocated: repeated aspirations combined with physiotherapy, and incision and drainage with contour pressure dressing, magnetotherapy etc. In recent years, a new technique with a drainage tube inserted into the pseudocyst using a guide needle has been used in our hospital in the treatment of this condition. We report 45 cases treated by this method, none of whom had the condition previously.

  20. Periorbital cyst with bone defect in a dog.

    PubMed

    Ito, Kanako; Asano, Kazushi; Urano, Toshiaki; Ogiwara, Naoki; Seki, Mamiko; Kato, Yuka; Sasaki, Yukie; Teshima, Kenji; Kutara, Kenji; Edamura, Kazuya; Shibuya, Hisashi; Tanaka, Shigeo

    2006-07-01

    A 4-year-old female Miniature Dachshund was referred with a chief complaint of right periorbital swelling that had not responded to antibiotic therapy. Ultrasonography and fine-needle aspiration revealed that the periorbital lesion had a cystic structure without any inflammatory or neoplastic cells. Computed tomography (CT) showed that the cyst occupied a defect in the periorbital maxillary, lacrimal, and frontal bones and had invaded the nasal cavity. The lesion was histologically suspected by incisional biopsy as an epithelial cyst.

Top