Rathinavelan, Thenmalarchelvi; Tang, Chun; De Guzman, Roberto N.
2011-01-01
Many Gram-negative bacteria that cause major diseases and mortality worldwide require the type III secretion system (T3SS) to inject virulence proteins into their hosts and cause infections. A structural component of the T3SS is the needle apparatus, which consists of a base, an external needle, and a tip complex. In Salmonella typhimurium, the external needle is assembled by the polymerization of the needle protein PrgI. On top of this needle sits a tip complex, which is partly formed by the tip protein SipD. How SipD interacts with PrgI during the assembly of the T3SS needle apparatus remains unknown. The central region of PrgI forms an α-helical hairpin, whereas SipD has a long central coiled-coil, which is a defining structural feature of other T3SS tip proteins as well. Using NMR paramagnetic relaxation enhancement, we have identified a specific region on the SipD coiled-coil that interacts directly with PrgI. We present a model of how SipD might dock at the tip of the needle based on our paramagnetic relaxation enhancement results, thus offering new insight about the mechanism of assembly of the T3SS needle apparatus. PMID:21138848
Veenendaal, Andreas K J; Hodgkinson, Julie L; Schwarzer, Lynn; Stabat, David; Zenk, Sebastian F; Blocker, Ariel J
2007-03-01
Type III secretion systems (T3SSs) are essential virulence determinants of many Gram-negative bacterial pathogens. The Shigella T3SS consists of a cytoplasmic bulb, a transmembrane region and a hollow 'needle' protruding from the bacterial surface. Physical contact with host cells initiates secretion and leads to assembly of a pore, formed by IpaB and IpaC, in the host cell membrane, through which proteins that facilitate host cell invasion are translocated. As the needle is implicated in host cell sensing and secretion regulation, its tip should contain components that initiate host cell contact. Through biochemical and immunological studies of wild-type and mutant Shigella T3SS needles, we reveal tip complexes of differing compositions and functional states, which appear to represent the molecular events surrounding host cell sensing and pore formation. Our studies indicate that the interaction between IpaB and IpaD at needle tips is key to host cell sensing, orchestration of IpaC secretion and its subsequent assembly at needle tips. This allows insertion into the host cell membrane of a translocation pore that is continuous with the needle.
Rathinavelan, Thenmalarchelvi; Lara-Tejero, Maria; Lefebre, Matthew; Chatterjee, Srirupa; McShan, Andrew C.; Guo, Da-Chuan; Tang, Chun; Galan, Jorge E.; De Guzman, Roberto N.
2014-01-01
Salmonella and other pathogenic bacteria use the type III secretion system (T3SS) to inject virulence proteins into human cells to initiate infections. The structural component of the T3SS contains a needle and a needle tip. The needle is assembled from PrgI needle protomers and the needle tip is capped with several copies of the SipD tip protein. How a tip protein docks on the needle is unclear. A crystal structure of a PrgI-SipD fusion protein docked on the PrgI needle results in steric clash of SipD at the needle tip when modeled on the recent atomic structure of the needle. Thus, there is currently no good model of how SipD is docked on the PrgI needle tip. Previously, we showed by NMR paramagnetic relaxation enhancement (PRE) methods that a specific region in the SipD coiled-coil is the binding site for PrgI. Others have hypothesized that a domain of the tip protein – the N-terminal α-helical hairpin, has to swing away during the assembly of the needle apparatus. Here, we show by PRE methods that a truncated form of SipD lacking the α-helical hairpin domain binds more tightly to PrgI. Further, PRE-based structure calculations revealed multiple PrgI binding sites on the SipD coiled-coil. Our PRE results together with the recent NMR-derived atomic structure of the Salmonella needle suggest a possible model of how SipD might dock at the PrgI needle tip. SipD and PrgI are conserved in other bacterial T3SSs, thus our results have wider implication in understanding other needle-tip complexes. PMID:24951833
Dickenson, Nicholas E.; Zhang, Lingling; Epler, Chelsea R.; Adam, Philip R.; Picking, Wendy L.; Picking, William D.
2011-01-01
Shigella flexneri uses its type III secretion apparatus (TTSA) to inject host-altering proteins into targeted eukaryotic cells. The TTSA is composed of a basal body and an exposed needle with invasion plasmid antigen D (IpaD) forming a tip complex that controls secretion. The bile salt deoxycholate (DOC) stimulates recruitment of the translocator protein IpaB into the maturing TTSA needle tip complex. This process appears to be triggered by a direct interaction between DOC and IpaD. Fluorescence spectroscopy and NMR spectroscopy are used here to confirm the DOC-IpaD interaction and to reveal that IpaD conformational changes upon DOC binding trigger the appearance of IpaB at the needle tip. Förster resonance energy transfer between specific sites on IpaD was used here to identify changes in distances between IpaD domains as a result of DOC binding. To further explore the effects of DOC binding on IpaD structure, NMR chemical shift mapping was employed. The environments of residues within the proposed DOC binding site and additional residues within the “distal” globular domain were perturbed upon DOC binding, further indicating that conformational changes occur within IpaD upon DOC binding. These events are proposed to be responsible for the recruitment of IpaB at the TTSA needle tip. Mutation analyses combined with additional spectroscopic analyses confirms that conformational changes in IpaD induced by DOC binding contribute to the recruitment of IpaB to the S. flexneri TTSA needle tip. These findings lay the foundation for determining how environmental factors promote TTSA needle tip maturation prior to host cell contact. PMID:21126091
Double needle technique: an alternative method for performing difficult sacroiliac joint injections.
Gupta, Sanjeeva
2011-01-01
The sacroiliac joint (SIJ) is a common source of low back pain. The most appropriate method of confirming SIJ pain is to inject local anesthesia into the joint to find out if the pain decreases. Unfortunately, although the SIJ is a large joint, it can be difficult to enter due to the complex nature of the joint and variations in anatomy. In my experience a double needle technique for sacroiliac joint injection can increase the chances of accurate injection into the SIJ in difficult cases. After obtaining appropriate fluoroscopic images, the tip of the needle is advanced into the SIJ. Once the tip of the needle is correctly placed, its position is checked under continuous fluoroscopy while moving the C-arm in the right and left oblique directions (dynamic fluoroscopy). On dynamic fluoroscopy the tip of the needle should remain within the joint line and not appear to be on the bone. If the tip of the needle appears to be on the bone a new joint line will need to be identified (the most translucent area through the joint) by dynamic fluoroscopy and another needle advanced into the newly identified joint line. Dynamic fluoroscopy is repeated again to confirm that the tip of the second needle remains within the joint line. Once both needles are in place contrast dye is injected through the needle that is most likely to be in the SIJ. If the contrast dye spread is not satisfactory then it is injected through the other needle. I have used this technique in 10 patients and found it very helpful in accurately performing SIJ injection which can at times be challenging.
NASA Astrophysics Data System (ADS)
Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro
2017-03-01
Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.
Methods for Improving the Curvature of Steerable Needles in Biological Tissue
Adebar, Troy K.; Greer, Joseph D.; Laeseke, Paul F.; Hwang, Gloria L.; Okamura, Allison M.
2016-01-01
Robotic needle steering systems have the potential to improve percutaneous interventions such as radiofrequency ablation of liver tumors, but steering techniques described to date have not achieved sufficiently small radius of curvature in biological tissue to be relevant to this application. In this work, the impact of tip geometry on steerable needle curvature is examined. Finite-element simulations and experiments with bent-tip needles in ex vivo liver tissue demonstrate that selection of tip length and angle can greatly improve curvature, with radius of curvature below 5 cm in liver tissue possible through judicious selection of these parameters. Motivated by the results of this analysis, a new articulated-tip steerable needle is described, in which a distal section is actively switched by a robotic system between a straight tip (resulting in a straight path) and a bent tip (resulting in a curved path). This approach allows the tip length and angle to be increased, while the straight configuration allows the needle tip to still pass through an introducer sheath and rotate inside the body. Validation testing in liver tissue shows that the new articulated-tip steerable needle achieves smaller radius of curvature compared to bent-tip needles described in previous work. Steerable needles with optimized tip parameters, which can generate tight curves in liver tissue, increase the clinical relevance of needle steering to percutaneous interventions. PMID:26441438
Development of Repulsive Barrier Discharge from Twin Needles
NASA Astrophysics Data System (ADS)
Ueno, Hideki; Hata, Koji; Nakayama, Hiroshi
2007-03-01
Barrier discharge characteristics have been investigated for a twin needles-to-plane electrode configuration in dry air. The characteristics of barrier discharge under ac voltage application have been investigated for various distances between two needle tips (d=1.0--4.0 mm). We have found that corona discharge behavior strongly depends on needle-tip distance. In the case of a twin-needles configuration with a long needle-tip distance (d=4.0 mm), discharges from the two needle tips develop into a dielectric barrier with almost a straight path. On the contrary, the development of repulsive discharges from two needle tips in the gap between needles and a barrier was obtained for the shortest needle-tip distance investigated here (d=1.0 mm) and it was enhanced by increasing the peak voltage. From detailed time-resolved observations, development of repulsive discharge was observed only during positive polarity upon ac voltage application. Moreover, the degree of repulsion increased with increasing applied voltage of positive polarity. The observed unique discharge behavior can be interpreted as the effect of field relaxation induced not only by charge accumulation on the barrier surface, which is markedly enhanced at a short needle-tip distance, but also by space charge by coronas between two needles.
Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.
Sadjadi, Hossein; Hashtrudi-Zaad, Keyvan; Fichtinger, Gabor
2013-10-01
We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.
Dickenson, Nicholas E.; Arizmendi, Olivia; Patil, Mrinalini K.; Toth, Ronald T.; Middaugh, C. Russell; Picking, William D.; Picking, Wendy L.
2014-01-01
The type III secretion system (T3SS) is an essential virulence factor for Shigella flexneri, providing a conduit through which host-altering effectors are injected directly into a host cell to promote uptake. The type III secretion apparatus (T3SA) is comprised of a basal body, external needle, and regulatory tip complex. The nascent needle is a polymer of MxiH capped by a pentamer of invasion plasmid antigen D (IpaD). Exposure to bile salts (e.g. deoxycholate) causes a conformational change in IpaD and promotes recruitment of IpaB to the needle tip. It has been proposed that IpaB senses contact with host cell membranes, recruiting IpaC and inducing full secretion of T3SS effectors. While the steps of T3SA maturation and their external triggers have been identified, details of specific protein interactions and mechanisms have remained difficult to study due to the hydrophobic nature of the IpaB and IpaC translocator proteins. Here we explored the ability for a series of soluble N-terminal IpaB peptides to interact with IpaD. We found that DOC is required for the interaction and that a region of IpaB between residues 11–27 is required for maximum binding, which was confirmed in vivo. Furthermore, intramolecular FRET measurements indicated that movement of the IpaD distal domain away from the protein core accompanied the binding of IpaB11-226. Together these new findings provide important new insight into the interactions and potential mechanisms that define the maturation of the Shigella T3SA needle tip complex and provide a foundation for further studies probing T3SS activation. PMID:24236510
Self-Chaperoning of the Type III Secretion System needle tip proteins IpaD and BipD
Johnson, Steven; Roversi, Pietro; Espina, Marianela; Olive, Andrew; Deane, Janet E.; Birket, Susan; Field, Terry; Picking, William D.; Blocker, Ariel; Galyov, Edouard E.; Picking, Wendy L.; Lea, Susan M.
2007-01-01
Bacteria expressing type III secretion systems (T3SS) have been responsible for the deaths of millions worldwide, acting as key virulence elements in diseases ranging from plague to typhoid fever. The T3SS is composed of a basal body, which traverses both bacterial membranes, and an external needle through which effector proteins are secreted. We report multiple crystal structures of two proteins that sit at the tip of the needle and are essential for virulence; IpaD from Shigella flexneri and BipD from Burkholderia pseudomallei. The structures reveal that the N-terminal domains of the molecules are intra-molecular chaperones that prevent premature oligomerization, as well as sharing structural homology with proteins involved in eukaryotic actin rearrangement. Crystal packing has allowed us to construct a model for the tip complex that is supported by mutations designed using the structure. PMID:17077085
Self-chaperoning of the type III secretion system needle tip proteins IpaD and BipD.
Johnson, Steven; Roversi, Pietro; Espina, Marianela; Olive, Andrew; Deane, Janet E; Birket, Susan; Field, Terry; Picking, William D; Blocker, Ariel J; Galyov, Edouard E; Picking, Wendy L; Lea, Susan M
2007-02-09
Bacteria expressing type III secretion systems (T3SS) have been responsible for the deaths of millions worldwide, acting as key virulence elements in diseases ranging from plague to typhoid fever. The T3SS is composed of a basal body, which traverses both bacterial membranes, and an external needle through which effector proteins are secreted. We report multiple crystal structures of two proteins that sit at the tip of the needle and are essential for virulence: IpaD from Shigella flexneri and BipD from Burkholderia pseudomallei. The structures reveal that the N-terminal domains of the molecules are intramolecular chaperones that prevent premature oligomerization, as well as sharing structural homology with proteins involved in eukaryotic actin rearrangement. Crystal packing has allowed us to construct a model for the tip complex that is supported by mutations designed using the structure.
NASA Astrophysics Data System (ADS)
Ueno, Hideki; Kawahara, Shintaro; Nakayama, Hiroshi
Relationship between barrier discharge characteristics and ozone generation under ac voltage application on triple needles-plane configuration has been investigated for various distances among triple needle-tips (d=0 ∼ 7.0mm) at constant distance between needle tip and plane (g=3.0mm) in dry air. Characteristics of barrier discharge and ozone generation depend on the needle-tips distance. It is considered that the influence is caused by space charge and accumulated charge suggested from discharge image by still camera and CCD camera. And ozone generation efficiency is also estimated by power consumption and ozone concentration. As a result, when the distance among triple needle-tips is narrow, the above-mentioned influence is strengthened. And in this case, ozone generation efficiency is improved.
SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.
Leu, S; Ruiz, B; Podder, T
2012-06-01
To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Covington, GA) were used. The TRUS was set at 6.5MHz in water phantom at 40°C and measurements were taken with 50% and 100% TRUS gains. Needles were oriented with bevel-tip facing up (0-degree) and inserted through template grid-holes. Reference needle depths were measured when needle tip image intensity was bright enough for potentially consistent readings. High-resolution digital vernier caliper was used to measure needle depth. Needle bevel-tip orientation was then changed to bevel down (by rotating 180-degree) and needle depth was adjusted by retracting so that the needle-tip image intensity appeared similar to when the needle bevel-tip was at 0-degree orientation. Clinically relevant locations were considered for needle placement on the template grids (1st row to 9th row, and 'a-f' columns). For 50% TRUS gain, bevel tip detection errors/differences were 0.69±0.30mm (1st row) to 3.23±0.22mm (9th row) and 0.78±0.71mm (1st row) to 4.14±0.56mm (9th row) in columns 'a' and 'D', respectively. The corresponding errors for 100% TRUS gain were 0.57±0.25mm to 5.24±0.36mm and 0.84±0.30mm to 4.2±0.20mm in columns 'a' and 'D', respectively. These errors/differences varied linearly for grid-hole locations on the rows and columns in between, smaller to large depending on distance from the TRUS probe. Observed no effect of gains (50% vs. 100%) along 'D' column, which was directly above the TRUS probe. Experiment results revealed that the beveled needle tip orientation could significantly impact the detection accuracy of the needle tips, based on which the seeds might be delivered. These errors may lead to considerable dosimetric deviations in prostate brachytherapy seed implantation. © 2012 American Association of Physicists in Medicine.
A Novel Actuator for Simulation of Epidural Anesthesia and Other Needle Insertion Procedures
Magill, John C.; Byl, Marten F.; Hinds, Michael F.; Agassounon, William; Pratt, Stephen D.; Hess, Philip E.
2010-01-01
Introduction When navigating a needle from skin to epidural space, a skilled clinician maintains a mental model of the anatomy and uses the various forms of haptic and visual feedback to track the location of the needle tip. Simulating the procedure requires an actuator that can produce the feel of tissue layers even as the needle direction changes from the ideal path. Methods A new actuator and algorithm architecture simulate forces associated with passing a needle through varying tissue layers. The actuator uses a set of cables to suspend a needle holder. The cables are wound onto spools controlled by brushless motors. An electromagnetic tracker is used to monitor the position of the needle tip. Results Novice and expert clinicians simulated epidural insertion with the simulator. Preliminary depth-time curves show that the user responds to changes in tissue properties as the needle is advanced. Some discrepancy in clinician response indicates that the feel of the simulator is sensitive to technique, thus perfect tissue property simulation has not been achieved. Conclusions The new simulator is able to approximately reproduce properties of complex multilayer tissue structures, including fine-scale texture. Methods for improving fidelity of the simulation are identified. PMID:20651481
A novel actuator for simulation of epidural anesthesia and other needle insertion procedures.
Magill, John C; Byl, Marten F; Hinds, Michael F; Agassounon, William; Pratt, Stephen D; Hess, Philip E
2010-06-01
When navigating a needle from skin to epidural space, a skilled clinician maintains a mental model of the anatomy and uses the various forms of haptic and visual feedback to track the location of the needle tip. Simulating the procedure requires an actuator that can produce the feel of tissue layers even as the needle direction changes from the ideal path. A new actuator and algorithm architecture simulate forces associated with passing a needle through varying tissue layers. The actuator uses a set of cables to suspend a needle holder. The cables are wound onto spools controlled by brushless motors. An electromagnetic tracker is used to monitor the position of the needle tip. Novice and expert clinicians simulated epidural insertion with the simulator. Preliminary depth-time curves show that the user responds to changes in tissue properties as the needle is advanced. Some discrepancy in clinician response indicates that the feel of the simulator is sensitive to technique, thus perfect tissue property simulation has not been achieved. The new simulator is able to approximately reproduce properties of complex multilayer tissue structures, including fine-scale texture. Methods for improving fidelity of the simulation are identified.
EUS Needle Identification Comparison and Evaluation study (with videos).
Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin Teodor; Fink, Peter P; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T; van der Heijden, Erik H F M; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R; Lee, Linda S; Aslanian, Harry R; Wang, Andrew Y; Shami, Vanessa M; Markowitz, Arnold; Siddiqui, Ali A; Mishra, Girish; Scheiman, James M; Isenberg, Gerard; Siddiqui, Uzma D; Shah, Raj J; Buxbaum, James; Watson, Rabindra R; Willingham, Field F; Bhutani, Manoop S; Levy, Michael J; Harris, Cynthia; Wallace, Michael B; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D'Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S; Freeman, Simon; McCowan, Timothy C; de Araujo, Cyrillo Rodrigues; Patel, Akash; Ali, Mohammad Adel; Campbell, Garth; Chen, Edward; Vilmann, Peter
2016-09-01
EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Descriptive bench-top testing and comparison of 8 commonly used EUS-FNA needles (all size 22 gauge): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in GI US examination who were unfamiliar with EUS needle devices. There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, 1 prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (P < .01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%-75% worse, P < .001). All FNA needles have their inherent and different echogenicities, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. Copyright © 2016 American Society for Gastrointestinal Endoscopy. All rights reserved.
Behavior of Tip-Steerable Needles in ex vivo and in vivo Tissue
Majewicz, Ann; Marra, Steven P.; van Vledder, Mark G.; Lin, MingDe; Choti, Michael A.; Song, Danny Y.; Okamura, Allison M.
2012-01-01
Robotic needle steering is a promising technique to improve the effectiveness of needle-based clinical procedures, such as biopsies and ablation, by computer-controlled, curved insertions of needles within solid organs. In this paper, we explore the capabilities, challenges, and clinical relevance of asymmetric-tip needle steering though experiments in ex vivo and in vivo tissue. We evaluate the repeatability of needle insertion in inhomogeneous biological tissue and compare ex vivo and in vivo needle curvature and insertion forces. Steerable needles curved more in kidney than in liver and prostate, likely due to differences in tissue properties. Pre-bent needles produced higher insertion forces in liver and more curvature in vivo than ex vivo. When compared to straight stainless steel needles, steerable needles did not cause a measurable increase in tissue damage and did not exert more force during insertion. The minimum radius of curvature achieved by pre-bent needles was 5.23 cm in ex vivo tissue, and 10.4 cm in in vivo tissue. The curvatures achieved by bevel tip needles were negligible for in vivo tissue. The minimum radius of curvature for bevel tip needles in ex vivo tissue was 16.4 cm; however, about half of the bevel tip needles had negligible curvatures. We also demonstrate a potential clinical application of needle steering by targeting and ablating overlapping regions of cadaveric canine liver. PMID:22711767
Coaxial needle insertion assistant with enhanced force feedback.
De Lorenzo, Danilo; Koseki, Yoshihiko; De Momi, Elena; Chinzei, Kiyoyuki; Okamura, Allison M
2013-02-01
Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user.
NASA Astrophysics Data System (ADS)
Beigi, Parmida; Rohling, Robert
2014-03-01
Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.
Structure and biophysics of type III secretion in bacteria.
Chatterjee, Srirupa; Chaudhury, Sukanya; McShan, Andrew C; Kaur, Kawaljit; De Guzman, Roberto N
2013-04-16
Many plant and animal bacterial pathogens assemble a needle-like nanomachine, the type III secretion system (T3SS), to inject virulence proteins directly into eukaryotic cells to initiate infection. The ability of bacteria to inject effectors into host cells is essential for infection, survival, and pathogenesis for many Gram-negative bacteria, including Salmonella, Escherichia, Shigella, Yersinia, Pseudomonas, and Chlamydia spp. These pathogens are responsible for a wide variety of diseases, such as typhoid fever, large-scale food-borne illnesses, dysentery, bubonic plague, secondary hospital infections, and sexually transmitted diseases. The T3SS consists of structural and nonstructural proteins. The structural proteins assemble the needle apparatus, which consists of a membrane-embedded basal structure, an external needle that protrudes from the bacterial surface, and a tip complex that caps the needle. Upon host cell contact, a translocon is assembled between the needle tip complex and the host cell, serving as a gateway for translocation of effector proteins by creating a pore in the host cell membrane. Following delivery into the host cytoplasm, effectors initiate and maintain infection by manipulating host cell biology, such as cell signaling, secretory trafficking, cytoskeletal dynamics, and the inflammatory response. Finally, chaperones serve as regulators of secretion by sequestering effectors and some structural proteins within the bacterial cytoplasm. This review will focus on the latest developments and future challenges concerning the structure and biophysics of the needle apparatus.
Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György
2009-08-01
Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers at positions (+/- standard deviation) -0.53 +/- 0.16, -0.16 +/- 0.14, and -0.30 +/- 0.16 mm using a gain of 15 dB. The minus sign indicates that the needle tips were detected more proximally than the actual position of the needle tip. When using a gain of -15 dB the mean values of two observers resulted in -0.62 +/- 0.08 and -0.51 +/- 0.12 mm. Additionally an alternative approach to the direct needle tip definition was investigated. Two observers detected the solid part of the needle tip in sagittal images. This solid part, often named as "dead space end," is the distance between the needle tip and the beginning of the hollow part of the implant needle. The dead space end is 6.2 mm for the investigated needle type. Two users found mean values of -6.70 +/- 0.16 and -7.00 +/- 0.06 mm, respectively, for 15 dB gain and -6.90 +/- 0.09 and -7.02 +/- 0.06 mm using the -15 dB gain setting. The results show that ultrasound-based needle tip definition in sagittal viewing mode is accurate. The inter- and intraobserver errors should, however, be taken into account. A lower gain setting of the ultrasound system reduces the intraobserver error.
Endpoint Accuracy in Manual Control of a Steerable Needle.
van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J
2017-02-01
To study the ability of a human operator to manually correct for errors in the needle insertion path without partial withdrawal of the needle by means of an active, tip-articulated steerable needle. The needle is composed of a 1.32-mm outer-diameter cannula, with a flexure joint near the tip, and a retractable stylet. The bending stiffness of the needle resembles that of a 20-gauge hypodermic needle. The needle functionality was evaluated in manual insertions by steering to predefined targets and a lateral displacement of 20 mm from the straight insertion line. Steering tasks were conducted in 5 directions and 2 tissue simulants under image guidance from a camera. The repeatability in instrument actuations was assessed during 100 mm deep automated insertions with a linear motor. In addition to tip position, tip angles were tracked during the insertions. The targeting error (mean absolute error ± standard deviation) during manual steering to 5 different targets in stiff tissue was 0.5 mm ± 1.1. This variability in manual tip placement (1.1 mm) was less than the variability among automated insertions (1.4 mm) in the same tissue type. An increased tissue stiffness resulted in an increased lateral tip displacement. The tip angle was directly controlled by the user interface, and remained unaffected by the tissue stiffness. This study demonstrates the ability to manually steer needles to predefined target locations under image guidance. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2015-01-01
Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600
Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle.
Elayaperumal, Santhi; Bae, Jung Hwa; Daniel, Bruce L; Cutkosky, Mark R
2014-09-01
This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024).
Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle
Elayaperumal, Santhi; Bae, Jung Hwa; Daniel, Bruce L.; Cutkosky, Mark R.
2015-01-01
This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024). PMID:26509101
In-plane ultrasonic needle tracking using a fiber-optic hydrophone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial
Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less
Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance
Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.
2017-01-01
Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026
Niazi, A U; Chin, K J; Jin, R; Chan, V W
2014-08-01
Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Modeling and Control of Needles with Torsional Friction
Reed, Kyle B.; Okamura, Allison M.; Cowan, Noah J.
2010-01-01
A flexible needle can be accurately steered by robotically controlling the bevel tip orientation as the needle is inserted into tissue. Friction between the long, flexible needle shaft and the tissue can cause a significant discrepancy between the orientation of the needle tip and the orientation of the base where the needle angle is controlled. Our experiments show that several common phantom tissues used in needle steering experiments impart substantial friction forces to the needle shaft, resulting in a lag of over 45° for a 10 cm insertion depth in some phantoms; clinical studies report torques large enough to cause similar errors during needle insertions. Such angle discrepancies will result in poor performance or failure of path planners and image-guided controllers, since the needles used in percutaneous procedures are too small for state-of-the-art imaging to accurately measure the tip angle. To compensate for the angle discrepancy, we develop an estimator using a mechanics-based model of the rotational dynamics of a needle being inserted into tissue. Compared to controllers that assume a rigid needle in a frictionless environment, our estimator-based controller improves the tip angle convergence time by nearly 50% and reduces the path deviation of the needle by 70%. PMID:19695979
Kalman filter-based EM-optical sensor fusion for needle deflection estimation.
Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan
2018-04-01
In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.
Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich
2005-02-01
Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.
C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.
Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J
2010-05-01
Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1/3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation. C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.
The influence of tip shape on bending force during needle insertion
van de Berg, Nick J.; de Jong, Tonke L.; van Gerwen, Dennis J.; Dankelman, Jenny; van den Dobbelsteen, John J.
2017-01-01
Steering of needles involves the planning and timely modifying of instrument-tissue force interactions to allow for controlled deflections during the insertion in tissue. In this work, the effect of tip shape on these forces was studied using 10 mm diameter needle tips. Six different tips were selected, including beveled and conical versions, with or without pre-bend or pre-curve. A six-degree-of-freedom force/torque sensor measured the loads during indentations in tissue simulants. The increased insertion (axial) and bending (radial) forces with insertion depth — the force-displacement slopes — were analyzed. Results showed that the ratio between radial and axial forces was not always proportional. This means that the tip load does not have a constant orientation, as is often assumed in mechanics-based steering models. For all tip types, the tip-load assumed a more radial orientation with increased axial load. This effect was larger for straight tips than for pre-bent or pre-curved tips. In addition, the force-displacement slopes were consistently higher for (1) increased tip angles, and for (2) beveled tips compared to conical tips. Needles with a bent or curved tip allow for an increased bending force and a decreased variability of the tip load vector orientation. PMID:28074939
NASA Astrophysics Data System (ADS)
Baghdadchi, Saharnaz; Chao, Cherng; Esener, Sadik; Mattrey, Robert F.; Eghtedari, Mohammad A.
2017-02-01
Image-guided procedures are performed frequently by radiologists to insert a catheter within a target vessel or lumen or to perform biopsy of a lesion. For instance, an interventional radiologist uses fluoroscopy during percutaneous biliary drainage procedure (a procedure during which a catheter is inserted through the skin to drain the bile from liver) to identify the location of the needle tip within liver parenchyma, hepatic blood vessel or bile duct. However, the identification of the target organ under fluoroscopy exposes the patient to x-ray irradiation, which may be significant if the time of procedure is prolonged. We have designed a fiber core needle system that may help the radiologist identify the location of the needle tip in real time without exposing the patient to x-ray. Our needle system transmits a low power modulated light into the tissue through a fiber cable embedded in the needle and detects the backscattered light using another fiber inside the needle. We were able to successfully distinguish the location of our prototype needle tip inside a cow liver phantom to identify if the needle tip was within liver parenchyma, liver vessels, or in the bile duct based on the recorded backscattered light.
Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.
Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R
2017-07-01
Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.
Robot-Assisted Needle Steering
Reed, Kyle B.; Majewicz, Ann; Kallem, Vinutha; Alterovitz, Ron; Goldberg, Ken; Cowan, Noah J.; Okamura, Allison M.
2012-01-01
Needle insertion is a critical aspect of many medical treatments, diagnostic methods, and scientific studies, and is considered to be one of the simplest and most minimally invasive medical procedures. Robot-assisted needle steering has the potential to improve the effectiveness of existing medical procedures and enable new ones by allowing increased accuracy through more dexterous control of the needle tip path and acquisition of targets not accessible by straight-line trajectories. In this article, we describe a robot-assisted needle steering system that uses three integrated controllers: a motion planner concerned with guiding the needle around obstacles to a target in a desired plane, a planar controller that maintains the needle in the desired plane, and a torsion compensator that controls the needle tip orientation about the axis of the needle shaft. Experimental results from steering an asymmetric-tip needle in artificial tissue demonstrate the effectiveness of the system and its sensitivity to various environmental and control parameters. In addition, we show an example of needle steering in ex vivo biological tissue to accomplish a clinically relevant task, and highlight challenges of practical needle steering implementation. PMID:23028210
Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia
2012-08-15
Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less
Study on design and cutting parameters of rotating needles for core biopsy.
Giovannini, Marco; Ren, Huaqing; Cao, Jian; Ehmann, Kornel
2018-06-15
Core needle biopsies are widely adopted medical procedures that consist in the removal of biological tissue to better identify a lesion or an abnormality observed through a physical exam or a radiology scan. These procedures can provide significantly more information than most medical tests and they are usually performed on bone lesions, breast masses, lymph nodes and the prostate. The quality of the samples mainly depends on the forces exerted by the needle during the cutting process. The reduction of these forces is critical to extract high-quality tissue samples. The most critical factors that affect the cutting forces are the geometry of the needle tip and its motion while it is penetrating the tissue. However, optimal needle tip configurations and cutting parameters are not well established for rotating insertions. In this paper, the geometry and cutting forces of hollow needles are investigated. The fundamental goal of this study is to provide a series of guidelines for clinicians and surgeons to properly select the optimal tip geometries and speeds. Analytical models related to the cutting angles of several needle tip designs are presented and compared. Several needle tip geometries were manufactured from a 14-gauge cannula, commonly adopted during breast biopsies. The needles were then tested at different speeds and on different phantom tissues. According to these experimental measurements recommendations were formulated for rotating needle insertions. The findings of this study can be applied and extended to several biopsy procedures in which a cannula is used to extract tissue samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation
Moreira, Pedro; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2014-01-01
Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes. Accurate placement of the needle tip is important to the success of many needle procedures. The current needle steering systems depend on needle-tissue-specific data, such as maximum curvature, that is unavailable prior to an interventional procedure. In this paper, we present a novel three-dimensional adaptive steering method for flexible bevel-tipped needles that is capable of performing accurate tip placement without previous knowledge about needle curvature. The method steers the needle by integrating duty-cycled needle steering, online curvature estimation, ultrasound-based needle tracking, and sampling-based motion planning. The needle curvature estimation is performed online and used to adapt the path and duty cycling. We evaluated the method using experiments in a homogenous gelatin phantom, a two-layer gelatin phantom, and a biological tissue phantom composed of a gelatin layer and in vitro chicken tissue. In all experiments, virtual obstacles and targets move in order to represent the disturbances that might occur due to tissue deformation and physiological processes. The average targeting error using our new adaptive method is 40% lower than using the conventional non-adaptive duty-cycled needle steering method. PMID:26229729
Augmented reality guidance system for peripheral nerve blocks
NASA Astrophysics Data System (ADS)
Wedlake, Chris; Moore, John; Rachinsky, Maxim; Bainbridge, Daniel; Wiles, Andrew D.; Peters, Terry M.
2010-02-01
Peripheral nerve block treatments are ubiquitous in hospitals and pain clinics worldwide. State of the art techniques use ultrasound (US) guidance and/or electrical stimulation to verify needle tip location. However, problems such as needle-US beam alignment, poor echogenicity of block needles and US beam thickness can make it difficult for the anesthetist to know the exact needle tip location. Inaccurate therapy delivery raises obvious safety and efficacy issues. We have developed and evaluated a needle guidance system that makes use of a magnetic tracking system (MTS) to provide an augmented reality (AR) guidance platform to accurately localize the needle tip as well as its projected trajectory. Five anesthetists and five novices performed simulated nerve block deliveries in a polyvinyl alcohol phantom to compare needle guidance under US alone to US placed in our AR environment. Our phantom study demonstrated a decrease in targeting attempts, decrease in contacting of critical structures, and an increase in accuracy of 0.68 mm compared to 1.34mm RMS in US guidance alone. Currently, the MTS uses 18 and 21 gauge hypodermic needles with a 5 degree of freedom sensor located at the needle tip. These needles can only be sterilized using an ethylene oxide process. In the interest of providing clinicians with a simple and efficient guidance system, we also evaluated attaching the sensor at the needle hub as a simple clip-on device. To do this, we simultaneously performed a needle bending study to assess the reliability of a hub-based sensor.
NASA Astrophysics Data System (ADS)
Rodgers, J.; Tessier, D.; D'Souza, D.; Leung, E.; Hajdok, G.; Fenster, A.
2016-04-01
High-dose-rate (HDR) interstitial brachytherapy is often included in standard-of-care for gynaecological cancers. Needles are currently inserted through a perineal template without any standard real-time imaging modality to assist needle guidance, causing physicians to rely on pre-operative imaging, clinical examination, and experience. While two-dimensional (2D) ultrasound (US) is sometimes used for real-time guidance, visualization of needle placement and depth is difficult and subject to variability and inaccuracy in 2D images. The close proximity to critical organs, in particular the rectum and bladder, can lead to serious complications. We have developed a three-dimensional (3D) transrectal US system and are investigating its use for intra-operative visualization of needle positions used in HDR gynaecological brachytherapy. As a proof-of-concept, four patients were imaged with post-insertion 3D US and x-ray CT. Using software developed in our laboratory, manual rigid registration of the two modalities was performed based on the perineal template's vaginal cylinder. The needle tip and a second point along the needle path were identified for each needle visible in US. The difference between modalities in the needle trajectory and needle tip position was calculated for each identified needle. For the 60 needles placed, the mean trajectory difference was 3.23 +/- 1.65° across the 53 visible needle paths and the mean difference in needle tip position was 3.89 +/- 1.92 mm across the 48 visible needles tips. Based on the preliminary results, 3D transrectal US shows potential for the development of a 3D US-based needle guidance system for interstitial gynaecological brachytherapy.
Nanofiber electrode and method of forming same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pintauro, Peter N.; Zhang, Wenjing
In one aspect, a method of forming an electrode for an electrochemical device is disclosed. In one embodiment, the method includes the steps of mixing at least a first amount of a catalyst and a second amount of an ionomer or uncharged polymer to form a solution and delivering the solution into a metallic needle having a needle tip. The method further includes the steps of applying a voltage between the needle tip and a collector substrate positioned at a distance from the needle tip, and extruding the solution from the needle tip at a flow rate such as tomore » generate electrospun fibers and deposit the generated fibers on the collector substrate to form a mat with a porous network of fibers. Each fiber in the porous network of the mat has distributed particles of the catalyst. The method also includes the step of pressing the mat onto a membrane.« less
[Sheng's acupuncture manipulation at bone-nearby acupoints and the academic thoughts].
Sheng, Ji-li; Jin, Xiao-qing
2014-11-01
Sheng's acupuncture manipulation at bone-nearby acupoints is a set of needling manipulation of the chief physician of TCM, SHENG Xie-sun, summarized through his over 50 years clinical experiences and on the basis of Internal Classic. Regarding this manipulation, on the premise of acupoint selection based on syndrome differentiation, the acupoints close to bone are possibly selected and punctured, with the needle tip toward bone edge, and followed by the technique to achieve reducing purpose. Clinically, the significant immediate analgesia can be achieved in pain disorders such as headache and toothache. Professor Sheng thought, corresponding to the location of needle insertion and needling depth, the tissue layers of needle tip passing through should be considered specially. The site of needle insertion should be changeable so as to ensure the needle tip reaching the bone. This manipulation for analgesia provides a certain guide for acupuncture study, especially for the mechanism study on acupuncture analgesia.
Zheng, Dandan; Todor, Dorin A
2011-01-01
In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Warren, Jamie M; Pawliszyn, Janusz
2011-12-16
For air/headspace analysis, needle trap devices (NTDs) are applicable for sampling a wide range of volatiles such as benzene, alkanes, and semi-volatile particulate bound compounds such as pyrene. This paper describes a new NTD that is simpler to produce and improves performance relative to previous NTD designs. A NTD utilizing a side-hole needle used a modified tip, which removed the need to use epoxy glue to hold sorbent particles inside the NTD. This design also improved the seal between the NTD and narrow neck liner of the GC injector; therefore, improving the desorption efficiency. A new packing method has been developed and evaluated using solvent to pack the device, and is compared to NTDs prepared using the previous vacuum aspiration method. The slurry packing method reduced preparation time and improved reproducibility between NTDs. To evaluate the NTDs, automated headspace extraction was completed using benzene, toluene, ethylbenzene, p-xylene (BTEX), anthracene, and pyrene (PAH). NTD geometries evaluated include: blunt tip with side-hole needle, tapered tip with side-hole needle, slider tip with side-hole, dome tapered tip with side-hole and blunt with no side-hole needle (expanded desorptive flow). Results demonstrate that the tapered and slider tip NTDs performed with improved desorption efficiency. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Song, Liang; Chen, Lizhen; Cao, Duanlin; Wang, Jianlong
2018-02-01
In this article, a method was performed to predict the morphology of needle-shaped crystals by analyzing the growth mechanisms for the various crystal faces. As an example, the crystal morphology of a nitroguanidine (NQ) was investigated via molecular dynamics simulations. The modified attachment energy (MEA) model was constructed by introducing surface chemistry terms and the relevant morphology of the habit crystal faces. The results indicate that the growth morphology of NQ in vacuum is dominated by {2 2 0}, {0 4 0}, {1 1 1}, {1 3 1} and {3 1 1} faces. The {2 2 0} and {0 4 0} faces are parallel to the elongation direction of the crystal, while the other faces are at the needle tips direction. The atoms or atomic groups exposed in crystal surface were used to analyze the relationship between structure and morphology. Compared to the surrounding faces, the needle tip faces have a large number of polar atoms or atomic groups. The needle tip faces have a high electronegativity on N, O atoms via molecular electrostatic potential (ESP) analysis. Furthermore, the protic solvent was used to reduce the attachment energy of the tip surfaces for achieving the purpose of inhibiting the growth of needle tips. Gamma-butyrolactone as the selected solvent inhibited effectively the growth of the needle tip faces. The predicted result is serviceable for the formation design.
[Learning experience of acupuncture technique from professor ZHANG Jin].
Xue, Hongsheng; Zhang, Jin
2017-08-12
As a famous acupuncturist in the world, professor ZHANG Jin believes the key of acupuncture technique is the use of force, and the understanding of the "concentrating the force into needle body" is essential to understand the essence of acupuncture technique. With deep study of Huangdi Neijing ( The Inner Canon of Huangdi ) and Zhenjiu Dacheng ( Compendium of Acupuncture and Moxibustion ), the author further learned professor ZHANG Jin 's theory and operation specification of "concentrating force into needle body, so the force arriving before and together with needle". The whole-body force should be subtly focused on the tip of needle, and gentle force at tip of needle could get significant reinforcing and reducing effect. In addition, proper timing at tip of needle could start reinforcing and reducing effect, lead qi to disease location, and achieve superior clinical efficacy.
CT-Guided Interventions Using a Free-Hand, Optical Tracking System: Initial Clinical Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubert, Tilman, E-mail: TSchubert@uhbs.ch; Jacob, Augustinus L.; Pansini, Michele
2013-08-01
PurposeThe present study was designed to evaluate the geometrical accuracy and clinical applicability of a new, free-hand, CT-guided, optical navigation system.MethodsFifteen procedures in 14 consecutive patients were retrospectively analyzed. The navigation system was applied for interventional procedures on small target lesions, in cases with long needle paths, narrow access windows, or when an out-of-plane access was expected. Mean lesion volume was 27.9 ml, and mean distance to target measured was 107.5 mm. Eleven of 15 needle trajectories were planned as out-of-plane approaches regarding the axial CT plane.ResultsNinety-one percent of the biopsies were diagnostic. All therapeutic interventions were technically successful. Targetingmore » precision was high with a mean distance of the needle tip from planned target of 1.98 mm. Mean intervention time was 1:12 h. A statistically significant correlation between angular needle deviation and intervention time (p = 0.007), respiratory movement of the target (p = 0.008), and body mass index (p = 0.02) was detected. None of the evaluated parameters correlated significantly with the distance from the needle tip to the planned target.ConclusionsThe application of a navigation system for complex CT-guided procedures provided safe and effective targeting within a reasonable intervention time in our series.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wonneberger, Uta, E-mail: uta.wonneberger@charite.d; Schnackenburg, Bernhard, E-mail: bernhard.schnackenburg@philips.co; Streitparth, Florian, E-mail: florian.streitparth@charite.de
2010-04-15
In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0{sup o} to 90{sup o}) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring wasmore » assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width <3.5 mm, tip error <2 mm) at 45{sup o} to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNR{sub Muscle/Needle} >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.« less
NASA Astrophysics Data System (ADS)
Kumar, Saurabh; Shrikanth, Venkoba; Amrutur, Bharadwaj; Asokan, Sundarrajan; Bobji, Musuvathi S.
2016-12-01
Several medical procedures involve the use of needles. The advent of robotic and robot assisted procedures requires dynamic estimation of the needle tip location during insertion for use in both assistive systems as well as for automatic control. Most prior studies have focused on the maneuvering of solid flexible needles using external force measurements at the base of the needle holder. However, hollow needles are used in several procedures and measurements of forces in proximity of such needles can eliminate the need for estimating frictional forces that have high variations. These measurements are also significant for endoscopic procedures in which measurement of forces at the needle holder base is difficult. Fiber Bragg grating sensors, due to their small size, inert nature, and multiplexing capability, provide a good option for this purpose. Force measurements have been undertaken during needle insertion into tissue mimicking phantoms made of polydimethylsiloxane as well as chicken tissue using an 18-G needle instrumented with FBG sensors. The results obtained show that it is possible to estimate the different stages of needle penetration including partial rupture, which is significant for procedures in which precise estimation of needle tip position inside the organ or tissue is required.
Koontz, Nicholas A; Wiggins, Richard H; Stoddard, Gregory J; Shah, Lubdha M
2017-10-01
There is a paucity of evidence-based literature regarding the advantages and disadvantages of the interlaminar approach and needle bevel orientation for performing a lumbar interlaminar epidural steroid injection (ESI). The purpose of this study was to determine if superior versus inferior lamina approach, needle bevel tip orientation, or both may predispose to inadvertent nonepidural penetration during lumbar interlaminar ESI. A prospective study was performed of patients with low back pain with or without radicular pain or neurogenic claudication referred for lumbar interlaminar ESI. Two hundred eleven patients were randomized by interlaminar approach (superior vs inferior) and bevel tip orientation (cranial vs caudal). Lumbar interlaminar ESI was performed by six interventionalists of varying levels of experience using fluoroscopic guidance with curved tip epidural needles, using loss-of-resistance technique and confirmation with contrast opacification. Exact Poisson regression was used to model the study outcome. Two hundred twenty-one lumbar interlaminar ESIs were performed on 211 patients, randomized to a superior (n = 121) or inferior lamina approach (n = 100) and to a cranial (n = 103) or caudal (n = 118) orientation of the bevel tip. Epidural needle placement was confirmed in 96.4% (n = 213) of cases. Nonepidural needle placement was most commonly associated with superior lamina approach and caudal bevel tip orientation, which was marginally significant (adjusted risk ratio, 6.88; 95% CI, 0.93-∞; p = 0.059). Inadvertent nonepidural needle penetration during fluoroscopically guided lumbar interlaminar ESI appears to be affected by approach, with superior lamina approach and caudal bevel tip orientation being the least favorable technique.
Needle position estimation from sub-sampled k-space data for MRI-guided interventions
NASA Astrophysics Data System (ADS)
Schmitt, Sebastian; Choli, Morwan; Overhoff, Heinrich M.
2015-03-01
MRI-guided interventions have gained much interest. They profit from intervention synchronous data acquisition and image visualization. Due to long data acquisition durations, ergonomic limitations may occur. For a trueFISP MRI-data acquisition sequence, a time sparing sub-sampling strategy has been developed that is adapted to amagnetic needle detection. A symmetrical and contrast rich susceptibility needle artifact, i.e. an approximately rectangular gray scale profile is assumed. The 1-D-Fourier transformed of a rectangular function is a sinc-function. Its periodicity is exploited by sampling only along a few orthogonal trajectories in k-space. Because a needle moves during intervention, its tip region resembles a rectangle in a time-difference image that is reconstructed from such sub-sampled k-spaces acquired at different time stamps. In different phantom experiments, a needle was pushed forward along a reference trajectory, which was determined from a needle holders geometric parameters. In addition, the trajectory of the needle tip was estimated by the method described above. Only ca. 4 to 5% of the entire k-space data was used for needle tip estimation. The misalignment of needle orientation and needle tip position, i.e. the differences between reference and estimated values, is small and even in its worst case less than 2 mm. The results show that the method is applicable under nearly real conditions. Next steps are addressed to the validation of the method for clinical data.
Espina, Marianela; Ausar, S. Fernando; Middaugh, C. Russell; Baxter, M. Aaron; Picking, William D.; Picking, Wendy L.
2007-01-01
Diverse Gram-negative bacteria use type III secretion systems (T3SS) to translocate effector proteins into the cytoplasm of eukaryotic cells. The type III secretion apparatus (T3SA) consists of a basal body spanning both bacterial membranes and an external needle. A sensor protein lies at the needle tip to detect environmental signals that trigger type III secretion. The Shigella flexneri T3SA needle tip protein, invasion plasmid antigen D (IpaD), possesses two independently folding domains in vitro. In this study, the solution behavior and thermal unfolding properties of IpaD's functional homologs SipD (Salmonella spp.), BipD (Burkholderia pseudomallei), LcrV (Yersinia spp.), and PcrV (Pseudomonas aeruginosa) were examined to identify common features within this protein family. CD and FTIR data indicate that all members within this group are α-helical with properties consistent with an intramolecular coiled-coil. SipD showed the most complex unfolding profile consisting of two thermal transitions, suggesting the presence of two independently folding domains. No evidence of multiple folding domains was seen, however, for BipD, LcrV, or PcrV. Thermal studies, including DSC, revealed significant destabilization of LcrV, PcrV, and BipD after N-terminal deletions. This contrasted with SipD and IpaD, which behaved like two-domain proteins. The results suggest that needle tip proteins share significant core structural similarity and thermal stability that may be the basis for their common function. Moreover, IpaD and SipD possess properties that distinguish them from the other tip proteins. PMID:17327391
NASA Astrophysics Data System (ADS)
Sang, Chaofeng; Sun, Jizhong; Ren, Chunsheng; Wang, Dezhen
2009-02-01
A model of one dimensional in position and three dimensional in velocity space self-consistent particle in cell with Monte Carlo collision technique was employed to simulate the argon discharge between the needle and plane electrodes at high pressure, in which a nanosecond rectangular pulse was applied to the needle electrode. The work focused on the investigation of the spatiotemporal evolution of the discharge versus the needle tip size and working gas pressure. The simulation results showed that the discharge occurred mainly in the region near the needle tip at atmospheric pressure, and that the small radius of the needle tip led to easy discharge. Reducing the gas pressure gave rise to a transition from a corona discharge to a glowlike discharge along the needle-to-plane direction. The microscopic mechanism for the transition can arguably be attributed to the peak of high-energy electrons occurring before the breakdown; the magnitude of the number of these electrons determined whether the breakdown can take place.
Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.
Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A
2012-12-01
To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Kavrut Ozturk, Nilgun; Kavakli, Ali Sait
2017-08-01
This prospective randomized study compared the coracoid and retroclavicular approaches to ultrasound-guided infraclavicular brachial plexus block (IBPB) in terms of needle tip and shaft visibility and quality of block. We hypothesized that the retroclavicular approach would increase needle tip and shaft visibility and decrease the number of needle passes compared to the coracoid approach. A total of 100 adult patients who received IBPB block for upper limb surgery were randomized into two groups: a coracoid approach group (group C) and a retroclavicular approach group (group R). In group C, the needle was inserted 2 cm medial and 2 cm inferior to the coracoid process and directed from ventral to dorsal. In group R, the needle insertion point was posterior to the clavicle and the needle was advanced from cephalad to caudal. All ultrasound images were digitally stored for analysis. The primary aim of the present study was to compare needle tip and shaft visibility between the coracoid approach and retroclavicular approach in patients undergoing upper limb surgery. The secondary aim was to investigate differences between the two groups in the number of needle passes, sensory and motor block success rates, surgical success rate, block performance time, block performance-related pain, patient satisfaction, use of supplemental local anesthetic and analgesic, and complications. Needle tip visibility and needle shaft visibility were significantly better in group R (p = 0.040, p = 0.032, respectively). Block performance time and anesthesia-related time were significantly shorter in group R (p = 0.022, p = 0.038, respectively). Number of needle passes was significantly lower in group R (p = 0.044). Paresthesia during block performance was significantly higher in group C (p = 0.045). There were no statistically significant differences between the two groups in terms of sensory or motor block success, surgical success, block-related pain, and patient satisfaction. The retroclavicular approach is associated with better needle tip and shaft visibility, reduced performance time and anesthesia-related time, less paresthesia during block performance, and fewer needle passes than the coracoid approach. TRıAL REGISTRY NUMBER: Clinicaltrials.gov (no. NCT02673086).
Xie, Yi Min; Xu, Shanqing; Zhang, Claire Shuiqing; Xue, Charlie Changli
2014-04-01
The present work examined the surface conditions and various other physical properties of sterilised single-use stainless steel acupuncture needles from two of the most popular brands widely used in many countries. Scanning electron microscope (SEM) images were taken for 10 randomly chosen needles from each brand. Further SEM images were taken after each of these needles underwent a standard manipulation with an acupuncture needling practice gel. A comparison of forces and torques during the needling process was also carried out. The SEM images revealed significant surface irregularities and inconsistencies at the needle tips, especially for needles from one of the two brands. Metallic lumps and small, loosely attached pieces of material were observed on the surfaces of some needles. Some of the lumps and pieces of material seen on the needle surfaces disappeared after the acupuncture manipulation. If these needles had been used on patients, the metallic lumps and small pieces of material could have been deposited in human tissues, which could have caused adverse events such as dermatitis. Malformed needle tips might also cause other adverse effects including bleeding, haematoma/bruising, or strong pain during needling. An off-centre needle tip could result in the needle altering its direction during insertion and consequently failing to reach the intended acupuncture point or damaging adjacent tissues. These findings highlight the need for improved quality control of acupuncture needles, with a view to further enhancing the safety and comfort of acupuncture users.
Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David
2017-09-01
To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P <.001). Longer and consistent cores were obtained using the new biopsy needles. Combined with an adjustable actuator, the physician can obtain specimens that include peripheral and anterior zone tissue in 1 core. Determination of cancer location on the longer specimens could enhance focal therapy planning. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Armstrong, G.; Cardon, L.; Vilkomerson, D.; Lipson, D.; Wong, J.; Rodriguez, L. L.; Thomas, J. D.; Griffin, B. P.
2001-01-01
This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.
Kwon, Won Kyoung; Kim, Ah Na; Lee, Pil Moo; Park, Cheol Hwan; Kim, Jae Hun
2016-01-01
Background. Caudal epidural steroid injections (CESIs) are an effective treatment for pain. If the injection spreads in a specific pattern depending on the needle position or bevel direction, it would be possible to inject the agent into a specific and desired area. Objectives. We conducted a prospective randomized trial to determine if the needle position and bevel direction have any effect on the epidural spreading pattern in CESI. Methods. Demographic data of the patient were collected. During CESI, the needle position (middle or lateral) and direction (ventral or dorsal) were randomly allocated. Following fluoroscope-guided injection of 4 mL contrast media and 10 mL of injectates, the epidural spreading patterns (ventral or dorsal, bilateral or lateral) were imaged. Results. In the 210 CESIs performed, the needle tip position and bevel direction did not influence the epidural spreading patterns at L4-5 and L5-S1 disc levels. A history of Lumbar spine surgery was associated with a significantly limited spread to each disc level. A midline needle tip position was more effective than the lateral position in spreading to the distant disc levels. Conclusions. Neither the needle tip position nor the bevel direction affected the epidural drug spreading pattern during CESI. PMID:27445609
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barta, Michael L.; Guragain, Manita; Adam, Philip
2012-10-25
Type III secretion (TTS) is an essential virulence factor for Shigella flexneri, the causative agent of shigellosis. The Shigella TTS apparatus (TTSA) is an elegant nano-machine that is composed of a basal body, an external needle to deliver effectors into human cells, and a needle tip complex that controls secretion activation. IpaD is at the tip of the nascent TTSA needle where it controls the first step of TTS activation. The bile salt deoxycholate (DOC) binds to IpaD to induce recruitment of the translocator protein IpaB into the maturing tip complex. We recently used spectroscopic analyses to show that IpaDmore » undergoes a structural rearrangement that accompanies binding to DOC. Here, we report a crystal structure of IpaD with DOC bound and test the importance of the residues that make up the DOC binding pocket on IpaD function. IpaD binds DOC at the interface between helices {alpha}3 and {alpha}7, with concomitant movement in the orientation of helix {alpha}7 relative to its position in unbound IpaD. When the IpaD residues involved in DOC binding are mutated, some are found to lead to altered invasion and secretion phenotypes. These findings suggest that adoption of a DOC-bound structural state for IpaD primes the Shigella TTSA for contact with host cells. The data presented here and in the studies leading up to this work provide the foundation for developing a model of the first step in Shigella TTS activation.« less
Hyper- and viscoelastic modeling of needle and brain tissue interaction.
Lehocky, Craig A; Yixing Shi; Riviere, Cameron N
2014-01-01
Deep needle insertion into brain is important for both diagnostic and therapeutic clinical interventions. We have developed an automated system for robotically steering flexible needles within the brain to improve targeting accuracy. In this work, we have developed a finite element needle-tissue interaction model that allows for the investigation of safe parameters for needle steering. The tissue model implemented contains both hyperelastic and viscoelastic properties to simulate the instantaneous and time-dependent responses of brain tissue. Several needle models were developed with varying parameters to study the effects of the parameters on tissue stress, strain and strain rate during needle insertion and rotation. The parameters varied include needle radius, bevel angle, bevel tip fillet radius, insertion speed, and rotation speed. The results will guide the design of safe needle tips and control systems for intracerebral needle steering.
NASA Astrophysics Data System (ADS)
Hrinivich, W. Thomas; Hoover, Douglas A.; Surry, Kathleen; Edirisinghe, Chandima; Montreuil, Jacques; D'Souza, David; Fenster, Aaron; Wong, Eugene
2016-03-01
Background: High-dose-rate brachytherapy (HDR-BT) is a prostate cancer treatment option involving the insertion of hollow needles into the gland through the perineum to deliver a radioactive source. Conventional needle imaging involves indexing a trans-rectal ultrasound (TRUS) probe in the superior/inferior (S/I) direction, using the axial transducer to produce an image set for organ segmentation. These images have limited resolution in the needle insertion direction (S/I), so the sagittal transducer is used to identify needle tips, requiring a manual registration with the axial view. This registration introduces a source of uncertainty in the final segmentations and subsequent treatment plan. Our lab has developed a device enabling 3D-TRUS guided insertions with high S/I spatial resolution, eliminating the need to align axial and sagittal views. Purpose: To compare HDR-BT needle tip localization accuracy between 2D and 3D-TRUS. Methods: 5 prostate cancer patients underwent conventional 2D TRUS guided HDR-BT, during which 3D images were also acquired for post-operative registration and segmentation. Needle end-length measurements were taken, providing a gold standard for insertion depths. Results: 73 needles were analyzed from all 5 patients. Needle tip position differences between imaging techniques was found to be largest in the S/I direction with mean+/-SD of -2.5+/-4.0 mm. End-length measurements indicated that 3D TRUS provided statistically significantly lower mean+/-SD insertion depth error of -0.2+/-3.4 mm versus 2.3+/-3.7 mm with 2D guidance (p < .001). Conclusions: 3D TRUS may provide more accurate HDR-BT needle localization than conventional 2D TRUS guidance for the majority of HDR-BT needles.
Thermoelectric needle probe for temperature measurements in biological materials.
Korn, U; Rav-Noy, Z; Shtrikman, S; Zafrir, M
1980-04-01
In certain biological and medical applications it is important to measure and follow temperature changes inside a body or tissue. Any probe inserted into a tissue causes damage to tissue and distortion to the initial temperature distribution. To minimize this interference, a fine probe is needed. Thus, thin film technology is advantageous and was utilized by us to produce sensitive probes for these applications. The resulting probe is a small thermocouple at the tip of a thin needle (acupuncture stainless steel needle, approximately 0.26 mm in diameter and length in the range 5-10 cm was used). The junction was produced at the needle's tip by coating the needle with thin layers of insulating and thermoelectric materials. The first layer is an insulating one and is composed of polyacrylonitrile (PAN) and polymide produced by plasma polymerization and dip-coating respectively. This layer covers all the needle except the tip. The second layer is a vacuum deposited thermoelectric thin layer of Bi-5% Sb alloy coating also the tip. The third layer is for insulation and protection and is composed of PAN and polyimide. In this arrangement the junction is at the needle's tip, the needle is one conductor, the thermoelectric layer is the other and they are isolated by the plastic layer. The probe is handy and mechanically sturdy. The sensitivity is typically 77 microV/degrees C at room temperature and is constant to within 2% up to 90 degrees C. The response is fast (less than 1 sec) the noise is small, (less than 0.05 degrees C) and because of the small dimension, damage to tissue and disturbance to the measured temperature field are minimal.
Zenk, Sebastian F; Stabat, David; Hodgkinson, Julie L; Veenendaal, Andreas K J; Johnson, Steven; Blocker, Ariel J
2007-08-01
Type III secretion systems (T3SSs or secretons) are central virulence factors of many Gram-negative bacteria, used to inject protein effectors of virulence into eukaryotic host cells. Their overall morphology, consisting of a cytoplasmic region, an inner- and outer-membrane section and an extracellular needle, is conserved in various species. A portion of the secreton, containing the transmembrane regions and needle, has been isolated biochemically and termed the 'needle complex' (NC). However, there are still unsolved questions concerning the nature and relative arrangement of the proteins assembling the NC. Until these are resolved, the mode of function of the NC cannot be clarified. This paper describes an affinity purification method that enables highly efficient purification of Shigella NCs under near-physiological conditions. Using this method, three new minor components of the NC were identified by mass spectrometry: IpaD, a known component of the needle tip complex, and two predicted components of its central inner-membrane export apparatus, Spa40 and Spa24. A further minor component of the NC, MxiM, is only detected by immunoblotting. MxiM is a 'pilotin'-type protein for the outer-membrane 'secretin' ring formed of MxiD. As expected, it localized to the outer rim of the upper ring of NCs, validating the other findings.
[Research on electron density in DC needle-plate corona discharge at atmospheric pressure].
Liu, Zhi-Qiang; Guo, Wei; Liu, Tao-Tao; Wu, Wen-Shuo; Liu, Shu-Min
2013-11-01
Using needle-plate discharge device, corona discharge experiment was done in the atmosphere. Through photo of spot size of light-emitting area, the relationship between the voltage and thickness of corona layer was discussed. When the distance between tip and plate is fixed, the thickness of corona layer increases with the increase in voltage; when the voltage is fixed, the thickness of corona layer decreases with the increase in the distance between tip and plate. As spectral intensity of N2 (C3pi(u)) (337.1 nm)reflects high energy electron density, it was measured with emission spectrometry. The results show that high energy electron density is the biggest near the needle tip and the relationship between high energy electron density and voltage is basically linear increasing. Fixing voltage, high energy electron density decreases with the increase in the distance between tip and plate. When the voltage and the distance between tip and plate are fixed, the high energy electron density increases with the decrease in the curvature radius of needle tip. These results are of great importance for the study of plasma parameters of corona discharge.
Needle tip localization using stylet vibration.
Harmat, Adam; Rohling, Robert N; Salcudean, Septimiu E
2006-09-01
Power Doppler ultrasound is used to localize the tip of a needle by detecting physical vibrations. Two types of vibrations are investigated, lateral and axial. The lateral vibrations are created by rotating a stylet, whose tip is slightly bent, inside a stationary cannula while the stylet is completely within the cannula. The minute deflection at the needle tip when rotated causes tissue motion. The axial vibration is induced by extending and retracting a straight stylet inside a stationary cannula. The stylet's tip makes contact with the tissue and causes it to move. The lateral vibration method was found to perform approximately the same under a variety of configurations (e.g., different insertion angles and depths) and better than the axial vibration method. Tissue stiffness affects the performance of the lateral vibration method, but good images can be obtained through proper tuning of the ultrasound machine.
Dau, M; Buttchereit, I; Ganz, C; Frerich, B; Anisimova, E N; Daubländer, M; Kämmerer, P W
2017-11-01
The aims of this in vivo study were to evaluate the impact of needle bevel design on patients' pain perception and the mechanical deformation of the needle tip after the injection. In a prospective single-blinded trial, 150 patients received conventional infiltration anaesthesia for dental treatment by one examiner. Patients were randomized for one out of three different needle bevel types (scalpel-designed bevel needle (SB), n=50; triple bevel needle (TB), n=50; regular bevel needle (RB), n=50). Subjects' self-reported injection pain perception was evaluated using a numeric rating scale (NRS). For each needle tip, deformations after single use were measured using SEM. A significant lower injection pain level was found in SB (mean 2.1±1.2) than in TB (mean 3.5±1.6;) and RB (mean 3.4±1.0; all P<0.001). A needle deformation was detected in about 97.3% of all needles (SB 50/50, TB 50/50, and RB: 46/50). A higher number of barbs were found in SB (29/50) versus TB (17/50) and RB (19/50). For dental local infiltration anaesthesia, injection needles with a scalpel-designed bevel demonstrated significantly less injection pain. Needle tip deflections after anaesthetic agent infiltration, especially barbed hooks on the non-cutting edge may result in greater soft tissue trauma. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi
2016-07-01
This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.
NASA Astrophysics Data System (ADS)
Pekárek, Stanislav
2014-12-01
For the hollow-needle-to-mesh negative corona discharge in air, we studied the effect of placing the dielectric tube on the needle electrode and the effect of various positions of the end of this tube with respect to the tip of the needle electrode on the concentration of ozone produced by the discharge, the ozone production yield and the discharge V-A characteristics. We found that the placement of the dielectric tube on the needle electrode with a suitable position of this tube end with respect to the tip of the needle electrode for a particular discharge power led to a more than fourfold increase in the concentration of ozone produced by the discharge and also, for a constant airflow, the ozone production yield.
NASA Astrophysics Data System (ADS)
Ueno, Hideki; Kawano, Taichi; Sakamoto, Naoki; Nakayama, Hiroshi
For a needle-plane electrode system with a barrier, which establishes the electric field across the axis of a groove, creeping discharge characteristics in N2 gas under µs pulse voltage applications have been investigated. The distance h between the barrier surface and the needle tip as well as the distance M between the groove center and the needle tip were changed. In the case of h=0.3mm, when the needle tip is located near the far-side groove edge from the plane electrode (M=0.6mm), the flashover voltage has the maximum value. At that time, a growth of a corona is suppressed near the groove edge. These unique characteristics should associate with a field relaxation.
Yu, Robinson K.; Ghodadra, Anish; Agarwal, Vikas
2016-01-01
Background Lumbar transforaminal epidural steroid injection is a common and effective tool for managing lumbar radicular pain, although accidental intravascular injection can rarely result in paralysis. The purpose of this study is to determine the safest needle tip position for computed tomography (CT)-guided lumbar transforaminal epidural steroid injections as determined by incidence of intravascular injection. Methods Three radiologists, in consensus, reviewed procedural imaging for consecutive CT-fluoroscopic lumbar transforaminal epidural steroid injections performed during a 16-month period. Intravascular injections were identified and categorized by needle tip position, vessel type injected, intravascular injection volume and procedural phase containing the intravascular injection. Pearson chi-square and logistic regression testing were used to assess differences between groups, as appropriate. Results Intravascular injections occurred in 9% (52/606) of injections. The intravascular injection rate was significantly lower (P<0.001) for extraforaminal needle position (0%, 0/109) compared to junctional (8%, 27/319) and foraminal (14%, 25/178) needle tip positions. Of the intravascular injections, 4% (2/52) were likely arterial, 35% (18/52) were likely venous, and 62% (32/52) were indeterminate for vessel type injected. 46% (24/52) of intravascular injections were large volume, 33% (17/52) were small volume, and 21% (11/52) were trace volume. 56% (29/52) of intravascular injections occurred with the contrast trial dose, 29% (15/52) with the steroid/analgesic cocktail, and 15% (8/52) with both. Conclusions An extraforaminal needle position for CT-fluoroscopic lumbar transforaminal epidural steroid injections decreases the risk of intravascular injection and therefore may be safer than other needle tip positions. PMID:28097241
Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z
2016-07-01
Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Is Skin-Touch Sham Needle Not Placebo? A Double-Blind Crossover Study on Pain Alleviation
Homma, Ikuo; Izumizaki, Masahiko
2015-01-01
It remains an open question whether placebo/sham acupuncture, in which the needle tip presses the skin, can be used as a placebo device for research on pain. We compare the analgesic effect of the skin-touch placebo needle with that of the no-touch placebo needle, in which the needle tip does not touch the skin, in a double-blind crossover manner including no-treatment control in 23 healthy volunteers. The subjects received painful electrical stimulation in the forearm before and during needle retention to the LI 4 acupoint and after the removal of the needle and rated pain intensity using a visual analogue scale. We found no significant difference in analgesic effects among the skin-touch placebo needle, no-touch placebo needle, and no-treatment control at every point before, during, and after the treatments (p > 0.05). The results indicate that the skin-touch placebo needle can be used as a placebo device in clinical studies on pain. PMID:26064153
Spectral signatures of viewing a needle approaching one's body when anticipating pain.
Höfle, Marion; Pomper, Ulrich; Hauck, Michael; Engel, Andreas K; Senkowski, Daniel
2013-10-01
When viewing the needle of a syringe approaching your skin, anticipation of a painful prick may lead to increased arousal. How this anticipation is reflected in neural oscillatory activity and how it relates to activity within the autonomic nervous system is thus far unknown. Recently, we found that viewing needle pricks compared with Q-tip touches increases the pupil dilation response (PDR) and perceived unpleasantness of electrical stimuli. Here, we used high-density electroencephalography to investigate whether anticipatory oscillatory activity predicts the unpleasantness of electrical stimuli and PDR while viewing a needle approaching a hand that is perceived as one's own. We presented video clips of needle pricks and Q-tip touches, and delivered spatiotemporally aligned painful and nonpainful intracutaneous electrical stimuli. The perceived unpleasantness of electrical stimuli and the PDR were enhanced when participants viewed needle pricks compared with Q-tip touches. Source reconstruction using linear beamforming revealed reduced alpha-band activity in the posterior cingulate cortex (PCC) and fusiform gyrus before the onset of electrical stimuli when participants viewed needle pricks compared with Q-tip touches. Moreover, alpha-band activity in the PCC predicted PDR on a single trial level. The anticipatory reduction of alpha-band activity in the PCC may reflect a neural mechanism that serves to protect the body from forthcoming harm by facilitating the preparation of adequate defense responses. © 2013 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sekimoto, K.; Takayama, M.
2010-12-01
The change in the distribution pattern of negative ions HO-, NOx- and COx- observed on arbitrary point-to-plane electrode configuration has been investigated by varying the angle of needle to the plane electrode, under atmospheric pressure corona discharge conditions. The stationary inhomogeneous electric field distributions between the point-to-plane electrodes with arbitrary needle angle were calculated. The experimental and theoretical results obtained suggested that the negative ion evolutions progress along field lines established between the electrodes with arbitrary configurations and the resulting terminal ion formation on a given field line is attributable to the electric field strength on the needle tip surface where the field line arose. The NOx- and COx- ions were dominantly produced on the field lines arising from the needle tip apex region with the highest electric field strength, while the field lines emanating from the tip peripheral regions with lower field strength resulted in the formation of the HO- ion.
Container Closure Integrity Testing of Prefilled Syringes.
Peláez, Sarah S; Mahler, Hanns-Christian; Matter, Anja; Koulov, Atanas; Singh, Satish K; Germershaus, Oliver; Mathaes, Roman
2018-04-05
Prefilled syringes (PFSs) are increasingly preferred over vials as container closure systems (CCSs) for injectable drug products when facilitated or self-administration is required. However, PFSs are more complex compared to CCSs consisting of vial, rubber stopper, and crimp cap. Container closure integrity (CCI) assurance and verification has been a specific challenge for PFSs as they feature several sealing areas. A comprehensive understanding of the CCS is necessary for an appropriate CCI assessment as well as for packaging development and qualification. A comprehensive CCI assessment of 6 different PFSs from 3 different manufacturers (including 1 polymeric PFS) was conducted using helium leak testing. PFS components were manipulated to systematically assess the contribution of the different sealing areas to CCI, namely rigid needle shield (RNS)/needle, RNS/tip cone, and the individual ribs of a syringe plunger. The polymeric PFS required an equilibrium measurement for accurate container closure integrity testing. The different sealing areas and a single plunger rib were shown to provide adequate CCI. Acceptable tip cap movement until the point of CCI failure was estimated. The assessment of acceptable tip cap movement demonstrated the importance of considering the RNS/tip cone seal design to ensure CCI of the PFS upon post assembly possesses and shipment. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Effect of vibration frequency on biopsy needle insertion force.
Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei
2017-05-01
Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Simulation and experimental studies in needle-tissue interactions.
Konh, Bardia; Honarvar, Mohammad; Darvish, Kurosh; Hutapea, Parsaoran
2017-08-01
This work aims to introduce a new needle insertion simulation to predict the deflection of a bevel-tip needle inside soft tissue. The development of such a model, which predicts the steering behavior of the needle during needle-tissue interactions, could improve the performance of many percutaneous needle-based procedures such as brachytherapy and thermal ablation, by means of the virtual path planning and training systems of the needle toward the target and thus reducing possible incidents of complications in clinical practices. The Arbitrary-Lagrangian-Eulerian (ALE) formulation in LS-DYNA software was used to model the solid-fluid interactions between the needle and tissue. Since both large deformation and fracture of the continuum need to be considered in this model, applying ALE method for fluid analysis was considered a suitable approach. A 150 mm long needle was used to bend within the tissue due to the interacting forces on its asymmetric bevel tip. Three experimental cases of needle steering in a soft phantom were performed to validate the simulation. An error measurement of less than 10 % was found between the predicted deflection by the simulations and the one observed in experiments, validating our approach with reasonable accuracy. The effect of the needle diameter and its bevel tip angle on the final shape of the needle was investigated using this model. To maneuver around the anatomical obstacles of the human body and reach the target location, thin sharp needles are recommended, as they would create a smaller radius of curvature. The insertion model presented in this work is intended to be used as a base structure for path planning and training purposes for future studies.
New platform for evaluating ultrasound-guided interventional technologies
NASA Astrophysics Data System (ADS)
Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.
2016-04-01
Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.
Meyer, Jay J; Kuo, Annie F; Olson, Randall J
2010-06-01
To determine capsular breakage risk from contact by phacoemulsification needles by machine and tip type. Experimental laboratory investigation. Infiniti (Alcon, Inc.) with Intrepid cartridges and Signature (Abbott Medical Optics, Inc.) phacoemulsification machines were tested using 19- and 20-gauge sharp and rounded tips. Actual and unoccluded flow vacuum were determined at 550 mm Hg, bottle height of 75 cm, and machine-indicated flow rate of 60 mL/minute. Breakage from brief tip contact with a capsular surrogate and human cadaveric lenses was calculated. Nineteen-gauge tips had more flow and less unoccluded flow vacuum than 20-gauge tips for both machines, with highest unoccluded flow vacuum in the Infiniti. The 19-gauge sharp tip was more likely than the 20-gauge sharp tip to cause surrogate breakage for Signature with micropulse and Ellips (Abbott Medical Optics, Inc.) ultrasound at 100% power. For Infiniti using OZil (Alcon, Inc.) ultrasound, 20-gauge sharp tips were more likely than 19-gauge sharp tips to break the membrane. For cadaveric lenses, using rounded 20-gauge tips at 100% power, breakage rates were micropulse (2.3%), Ellips (2.3%), OZil (5.3%). Breakage rates for sharp 20-gauge Ellips tips were higher than for rounded tips. Factors influencing capsular breakage may include active vacuum at the tip, flow rate, needle gauge, and sharpness. Nineteen-gauge sharp tips were more likely than 20-gauge tips to cause breakage in lower vacuum methods. For higher-vacuum methods, breakage is more likely with 20-gauge than with 19-gauge tips. Rounded-edge tips are less likely than sharp-edged tips to cause breakage. Copyright 2010 Elsevier Inc. All rights reserved.
LES of cavitating flow inside a Diesel injector including dynamic needle movement
NASA Astrophysics Data System (ADS)
Örley, F.; Hickel, S.; Schmidt, S. J.; Adams, N. A.
2015-12-01
We perform large-eddy simulations (LES) of the turbulent, cavitating flow inside a 9-hole solenoid common-rail injector including jet injection into gas during a full injection cycle. The liquid fuel, vapor, and gas phases are modelled by a homogeneous mixture approach. The cavitation model is based on a thermodynamic equilibrium assumption. The geometry of the injector is represented on a Cartesian grid by a conservative cut-element immersed boundary method. The strategy allows for the simulation of complex, moving geometries with sub-cell resolution. We evaluate the effects of needle movement on the cavitation characteristics in the needle seat and tip region during opening and closing of the injector. Moreover, we study the effect of cavitation inside the injector nozzles on primary jet break-up.
Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C
2007-09-01
To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.
Needle tip visibility in 3D ultrasound images
NASA Astrophysics Data System (ADS)
Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo
2017-03-01
Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.
Experimental analysis of robot-assisted needle insertion into porcine liver.
Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie
2015-01-01
How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.
In vivo Monitoring of Serotonin by Nanomaterial Functionalized Acupuncture Needle
NASA Astrophysics Data System (ADS)
Li, Yu-Tao; Tang, Li-Na; Ning, Yong; Shu, Qing; Liang, Feng-Xia; Wang, Hua; Zhang, Guo-Jun
2016-06-01
Acupuncture treatment is amazing but controversial. Up to now, the mechanism of treating diseases by acupuncture and moxibustion is still unclear, especially the occurrence of the molecular events in local acupoints. Herein, we report an extremely stable microsensor by modifying carbon nanotube (CNT) to the tip surface of acupuncture needle and applying this CNT-modified acupuncture needle for real time monitoring of serotonin (5-HT) in vivo. To stabilize CNT modification on the needle tip surface, poly(3,4-ethylenedioxythiophene)(PEDOT) was employed as glue water to stick CNT on the needle. The detection limit of the CNT-modified needle was found to be approximately 50 nM and 78 nM in the PBS and the cell medium, respectively. In addition, the needle showed good selectivity to some inflammatory mediators and some electroactive molecules. For the first time, the CNT-modified needle could be directly probed into rat body for real time monitoring of 5-HT in vivo, showing a great potential for better understanding the mechanism of acupuncture treatment.
Marone, G; Francica, G; D'Angelo, V; Iodice, G; Pastore, P; Altamura, G; Cusati, B; Siani, A
1998-06-01
Radiofrequency hyperthermia using the newly-developed "cooled-tip" needle is one of the latest US-guided percutaneous treatments of hepatocellular carcinoma arising in cirrhosis. The continuous cooling of the needle tip allows tissue heating and necrosis far from the electrode without tissue charring, which was the major drawback of the old monopolar technique. Herein we report our preliminary results on feasibility and effectiveness of the thermoablation of mono- or paucifocal hepatocellular carcinoma with the cooled-tip needle. November, 1996, to January, 1998, we treated thirteen cirrhotic patients (mean age 69.5 yrs, 10 men, 12 HCV-positive; 11 in Child's Class A and 2 in Class B) with 19 hepatocellular carcinoma nodules (mean diameter: 27 mm; range: 10-41 mm; 6 with diameter > 3 cm). None of the patients had portal thrombosis and/or extrahepatic spread. We used a radiofrequency generator (100 W power) connected to an 18 G perfusion electrode needle with an exposed tip of 2-3 cm. The circuit is closed through a dispersive electrode positioned under the patient's thighs. A peristaltic pump infuses a chilled (2-5 degrees C) saline solution to guarantee the continuous cooling of the needle tip. The needle was placed into target lesions under US guidance. The interventional procedure was carried out under general anesthesia using Propofol without intubation. Dynamic CT (more recently with the helical technique) was carried out 15-20 days after thermoablation to assess treatment efficacy. In all, 31 thermal injuries (at 1000-1200 mA for 10-15 minutes) were caused in 21 sessions in the 19 hepatocellular carcinoma nodules (mean: 1.5 lesions per nodule and 1.6 sessions per patient). Complete necrosis as assessed at dynamic CT (no enhancement during the arteriographic phase) was achieved in 16 of 19 nodules (84%). No side-effects occurred. During the follow-up (median: 11 months) no death occurred and five patients had recurrent hepatocellular carcinoma appearing either as single nodule or as multinodular liver involvement. In our experience radiofrequency hyperthermia with the cooled-tip needle permits effective and safe percutaneous ablation of HCC in cirrhosis. In addition, treatment time is short and lesions > 3 cm can be treated. Further experience is needed to better define the role of percutaneous thermoablation in the treatment strategy of hepatocellular carcinoma.
Painless needle insertion in regional anesthesia of the eye.
Vaalamo, M O; Paloheimo, M P; Nikki, P H
1995-04-01
We examined a new technique of applying topical anesthetic with cotton tip sticks to the conjunctiva before needle insertion in regional anesthesia of the eye. Oxybuprocaine 0.4% and lidocaine 4% were compared with balanced salt solution (BSS) as topical anesthetics of the conjunctiva in Study 1. Ninety patients were randomly assigned into three groups (n = 30) to receive one of the three topical anesthetics in a double-blind manner. Pain of the needle insertions was measured with visual analog scale score (VAS) and quantitative surface electromography (qEMG). Both oxybuprocaine and lidocaine reduced pain significantly when compared to BSS. In Study 2, with healthy volunteers, we compared our previous practice of merely applying three consecutive drops of oxybuprocaine on the conjunctiva before needle insertions to the new technique of placing additional cotton tip sticks soaked in oxybuprocaine on the conjunctiva. We found the needle insertion virtually pain free when the cotton tip sticks were added to the topical anesthesia. The use of this simple method of topical anesthesia before the eye block increases patient comfort significantly.
Kao, Steven D; Morshedi, Maud M; Narsinh, Kazim H; Kinney, Thomas B; Minocha, Jeet; Picel, Andrew C; Newton, Isabel; Rose, Steven C; Roberts, Anne C; Kuo, Alexander; Aryafar, Hamed
2016-08-01
To assess whether intravascular ultrasound (US) guidance impacts number of needle passes, contrast usage, radiation dose, and procedure time during creation of transjugular intrahepatic portosystemic shunts (TIPS). Intravascular US-guided creation of TIPS in 40 patients was retrospectively compared with conventional TIPS in 49 patients between February 2010 and November 2015 at a single tertiary care institution. Patient sex and age, etiology of liver disease (hepatitis C virus, alcohol abuse, nonalcoholic steatohepatitis), severity of liver disease (mean Model for End-Stage Liver Disease score), and indications for TIPS (variceal bleeding, refractory ascites, refractory hydrothorax) in conventional and intravascular US-guided cases were recorded. The two groups were well matched by sex, age, etiology of liver disease, Child-Pugh class, Model for End-Stage Liver Disease scores, and indication for TIPS (P range = .19-.94). Fewer intrahepatic needle passes were required in intravascular US-guided TIPS creation compared with conventional TIPS (2 passes vs 6 passes, P < .01). Less iodinated contrast material was used in intravascular US cases (57 mL vs 140 mL, P < .01). Radiation exposure, as measured by cumulative dose, dose area product, and fluoroscopy time, was reduced with intravascular US (174 mGy vs 981 mGy, P < .01; 3,793 μGy * m(2) vs 21,414 μGy * m(2), P < .01; 19 min vs 34 min, P < .01). Procedure time was shortened with intravascular US (86 min vs 125 min, P < .01). Intravascular US guidance resulted in fewer intrahepatic needle passes, decreased contrast medium usage, decreased radiation dosage, and shortened procedure time in TIPS creation. Copyright © 2016 SIR. All rights reserved.
Analytic theory for the selection of 2-D needle crystal at arbitrary Peclet number
NASA Technical Reports Server (NTRS)
Tanveer, Saleh
1989-01-01
An accurate analytic theory is presented for the velocity selection of a two-dimensional needle crystal for arbitrary Peclet number for small values of the surface tension parameter. The velocity selection is caused by the effect of transcendentally small terms which are determined by analytic continuation to the complex plane and analysis of nonlinear equations. The work supports the general conclusion of previous small Peclet number analytical results of other investigators, though there are some discrepancies in details. It also addresses questions raised on the validity of selection theory owing to assumptions made on shape corrections at large distances from the tip.
Convolution neural networks for real-time needle detection and localization in 2D ultrasound.
Mwikirize, Cosmas; Nosher, John L; Hacihaliloglu, Ilker
2018-05-01
We propose a framework for automatic and accurate detection of steeply inserted needles in 2D ultrasound data using convolution neural networks. We demonstrate its application in needle trajectory estimation and tip localization. Our approach consists of a unified network, comprising a fully convolutional network (FCN) and a fast region-based convolutional neural network (R-CNN). The FCN proposes candidate regions, which are then fed to a fast R-CNN for finer needle detection. We leverage a transfer learning paradigm, where the network weights are initialized by training with non-medical images, and fine-tuned with ex vivo ultrasound scans collected during insertion of a 17G epidural needle into freshly excised porcine and bovine tissue at depth settings up to 9 cm and [Formula: see text]-[Formula: see text] insertion angles. Needle detection results are used to accurately estimate needle trajectory from intensity invariant needle features and perform needle tip localization from an intensity search along the needle trajectory. Our needle detection model was trained and validated on 2500 ex vivo ultrasound scans. The detection system has a frame rate of 25 fps on a GPU and achieves 99.6% precision, 99.78% recall rate and an [Formula: see text] score of 0.99. Validation for needle localization was performed on 400 scans collected using a different imaging platform, over a bovine/porcine lumbosacral spine phantom. Shaft localization error of [Formula: see text], tip localization error of [Formula: see text] mm, and a total processing time of 0.58 s were achieved. The proposed method is fully automatic and provides robust needle localization results in challenging scanning conditions. The accurate and robust results coupled with real-time detection and sub-second total processing make the proposed method promising in applications for needle detection and localization during challenging minimally invasive ultrasound-guided procedures.
Remenyik, Carl J.; Woychik, Richard P.; Patek, David R.; Hawk, James A.; Turner, John C.
1999-01-01
An electromechanical device for driving the tip of a microinjection cannula, or needle, through the outer barrier of a blastocyst, cell, or cell nucleus for the injection of cells or other bioactive materials. Either a flexible frame or a ram moving within a base member is employed. Cannula motion is achieved by means of a piezoelectric stack and spring return system. The thrust motion over a predetermined microscopic distance is achieved without cannula setback prior to the thrust movement. Instead of specially prepared beveled and tipped needles, standard unimproved cannulas or needles can be used.
Remenyik, C.J.; Woychik, R.P.; Patek, D.R.; Hawk, J.A.; Turner, J.C.
1999-03-02
An electromechanical device is disclosed for driving the tip of a microinjection cannula, or needle, through the outer barrier of a blastocyst, cell, or cell nucleus for the injection of cells or other bioactive materials. Either a flexible frame or a ram moving within a base member is employed. Cannula motion is achieved by means of a piezoelectric stack and spring return system. The thrust motion over a predetermined microscopic distance is achieved without cannula setback prior to the thrust movement. Instead of specially prepared beveled and tipped needles, standard unimproved cannulas or needles can be used. 6 figs.
Design of an Optically Controlled MR-Compatible Active Needle
Ryu, Seok Chang; Quek, Zhan Fan; Koh, Je-Sung; Renaud, Pierre; Black, Richard J.; Moslehi, Behzad; Daniel, Bruce L.; Cho, Kyu-Jin; Cutkosky, Mark R.
2015-01-01
An active needle is proposed for the development of magnetic resonance imaging (MRI)-guided percutaneous procedures. The needle uses a low-transition-temperature shape memory alloy (LT SMA) wire actuator to produce bending in the distal section of the needle. Actuation is achieved with internal optical heating using laser light transported via optical fibers and side coupled to the LT SMA. A prototype, with a size equivalent to a standard 16-gauge biopsy needle, exhibits significant bending, with a tip deflection of more than 14° in air and 5° in hard tissue. A single-ended optical sensor with a gold-coated tip is developed to measure the curvature independently of temperature. The experimental results in tissue phantoms show that human tissue causes fast heat dissipation from the wire actuator; however, the active needle can compensate for typical targeting errors during prostate biopsy. PMID:26512231
Impact of needle insertion depth on the removal of hard-tissue debris.
Perez, R; Neves, A A; Belladonna, F G; Silva, E J N L; Souza, E M; Fidel, S; Versiani, M A; Lima, I; Carvalho, C; De-Deus, G
2017-06-01
To evaluate the effect of depth of insertion of an irrigation needle tip on the removal of hard-tissue debris using micro-computed tomographic (micro-CT) imaging. Twenty isthmus-containing mesial roots of mandibular molars were anatomically matched based on similar morphological dimensions using micro-CT evaluation and assigned to two groups (n = 10), according to the depth of the irrigation needle tip during biomechanical preparation: 1 or 5 mm short of the working length (WL). The preparation was performed with Reciproc R25 file (tip size 25, .08 taper) and 5.25% NaOCl as irrigant. The final rinse was 17% EDTA followed by bidistilled water. Then, specimens were scanned again, and the matched images of the canals, before and after preparation, were examined to quantify the amount of hard-tissue debris, expressed as the percentage volume of the initial root canal volume. Data were compared statistically using the Mann-Whitney U-test. None of the tested needle insertion depths yielded root canals completely free from hard-tissue debris. The insertion depth exerted a significant influence on debris removal, with a significant reduction in the percentage volume of hard-tissue debris when the needle was inserted 1 mm short of the WL (P < 0.05). The insertion depth of irrigation needles significantly influenced the removal of hard-tissue debris. A needle tip positioned 1 mm short of the WL resulted in percentage levels of hard-tissue debris removal almost three times higher than when positioned 5 mm from the WL. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Chandra, Vinay; Gandi, Padma; Shivanna, Anil Kumar; Srinivas, Siva; Himgiri, S; Nischith, K G
2013-07-01
To evaluate the efficacy of NaviTip FX in removing the canal debris during root canal preparation using scanning electron microscopic study. Thirty single rooted teeth with completely formed apices were used in this study. Standard endodontic access cavity preparations were performed. Then the teeth were randomly divided into two groups: groups 1 and 2 of 15 teeth each group. For group 1, NaviTip FX (brush covered needle) was used to irrigate the canal with 5.25% sodium hypochlorite after each instrument use. For group 2, NaviTip (brushless needle) was used for irrigation following each instrument use. ProTaper rotary files were used for the canal preparation. The teeth were then cleaned and dried before splitting them into two halves. The half with most visible part of the apex was used for scanning electron microscopic evaluation. The results were statistically analyzed using the Mann-Whitney U-test at significance level p < 0.005. The mean values for coronal and middle third of group 1 showed lower debris scores than group 2 and this difference was statistically significant at a p-value 0.01 and 0.05 respectively, but no significance difference between them at the apical third at a p-value of < 0.05. The NaviTip FX (brush covered needle) showed effectively better canal wall debris removal than the NaviTip (brushless needle).
Adam, Philip R.; Patil, Mrinalini K.; Dickenson, Nicholas E.; Choudhari, Shyamal; Barta, Michael; Geisbrecht, Brian V.; Picking, Wendy L.; Picking, William D.
2012-01-01
Shigella flexneri uses its type III secretion system (T3SS) to promote invasion of human intestinal epithelial cells as the first step in causing shigellosis, a life threatening form of dysentery. The Shigella type III secretion apparatus (T3SA) consists of a basal body that spans the bacterial envelope and an exposed needle that injects effector proteins into target cells. The nascent Shigella T3SA needle is topped with a pentamer of the needle tip protein invasion plasmid antigen D (IpaD). Bile salts trigger recruitment of the first hydrophobic translocator protein, IpaB, to the tip complex where it senses contact with a host membrane. In the bacterial cytoplasm, IpaB exists in a complex with its chaperone IpgC. Several structures of IpgC have been solved and we recently reported the 2.1-Å crystal structure of the N-terminal domain (IpaB74.224) of IpaB. Like IpgC, the IpaB N-terminal domain exists as a homodimer in solution. We now report that when the two are mixed, these homodimers dissociate and form heterodimers having a nanomolar dissociation constant. This is consistent with the equivalent complexes co-purified after being co-expressed in E. coli. Fluorescence data presented here also indicate that the N-terminal domain of IpaB possesses two regions that appear to contribute additively to chaperone binding. It is also likely that the IpaB N terminus adopts an alternative conformation as a result of chaperone binding. The importance of these findings within the functional context of these proteins is discussed. PMID:22497344
Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery
NASA Astrophysics Data System (ADS)
Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.
2017-03-01
Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.
Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut; Mostbeck, Gerhard H
2011-01-01
Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images
NASA Astrophysics Data System (ADS)
Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.
2018-04-01
In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.
A microfluidic needle for sampling and delivery of chemical signals by segmented flows
NASA Astrophysics Data System (ADS)
Feng, Shilun; Liu, Guozhen; Jiang, Lianmei; Zhu, Yonggang; Goldys, Ewa M.; Inglis, David W.
2017-10-01
We have developed a microfluidic needle-like device that can extract and deliver nanoliter samples. The device consists of a T-junction to form segmented flows, parallel channels to and from the needle tip, and seven hydrophilic capillaries at the tip that form a phase-extraction region. The main microchannel is hydrophobic and carries segmented flows of water-in-oil. The hydrophilic capillaries transport the aqueous phase with a nearly zero pressure gradient but require a pressure gradient of 19 kPa for mineral oil to invade and flow through. Using this device, we demonstrate the delivery of nanoliter droplets and demonstrate sampling through the formation of droplets at the tip of our device. During sampling, we recorded the fluorescence intensities of the droplets formed at the tip while varying the concentration of dye outside the tip. We measured a chemical signal response time of approximately 3 s. The linear relationship between the recorded fluorescence intensity of samples and the external dye concentration (10-40 μg/ml) indicates that this device is capable of performing quantitative, real-time measurements of rapidly varying chemical signals.
Lytvynchuk, Lyubomyr; Sergienko, Andrij; Savytska, Iryna; Albert, Réka; Glittenberg, Carl; Binder, Susanne; Petrovski, Goran
2017-01-01
A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI) using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G) and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements. PMID:28692684
A novel curvature-controllable steerable needle for percutaneous intervention.
Bui, Van Khuyen; Park, Sukho; Park, Jong-Oh; Ko, Seong Young
2016-08-01
Over the last few decades, flexible steerable robotic needles for percutaneous intervention have been the subject of significant interest. However, there still remain issues related to (a) steering the needle's direction with less damage to surrounding tissues and (b) increasing the needle's maximum curvature for better controllability. One widely used approach is to control the fixed-angled bevel-tip needle using a "duty-cycle" algorithm. While this algorithm has shown its applicability, it can potentially damage surrounding tissue, which has prevented the widespread adoption of this technology. This situation has motivated the development of a new steerable flexible needle that can change its curvature without axial rotation, while at the same time producing a larger curvature. In this article, we propose a novel curvature-controllable steerable needle. The proposed robotic needle consists of two parts: a cannula and a stylet with a bevel-tip. The curvature of the needle's path is controlled by a control offset, defined by the offset between the bevel-tip and the cannula. As a result, the necessity of rotating the whole needle's body is decreased. The duty-cycle algorithm is utilized to a limited degree to obtain a larger radius of curvature, which is similar to a straight path. The first prototype of 0.46 mm (outer diameter) was fabricated and tested with both in vitro gelatin phantom and ex vivo cow liver tissue. The maximum curvatures measured 0.008 mm(-1) in 6 wt% gelatin phantom, 0.0139 mm(-1) in 10 wt% gelatin phantom, and 0.0038 mm(-1) in cow liver. The experimental results show a linear relationship between the curvature and the control offset, which can be utilized for future implementation of this control algorithm. © IMechE 2016.
[Academic origin of round magnetic needle and standardization operation].
Cheng, Yan-Ting; Zhang, Tian-Sheng; Meng, Li-Qiang; Shi, Rui-Qi; Ji, Lai-Xi
2014-07-01
The origin and development of round magnetic needle was explored, and the structure of round magnetic needle was introduced in detail, including the handle, the body and the tip of the needle. The clinical opera tion of round magnetic needle were standardized from the aspects of the methods of holding needle, manipulation skill, tapping position, strength of manipulation, application scope and matters needing attention, which laid foundation for the popularization and application of round magnetic needle.
Francica, G; Marone, G
1999-05-01
Radiofrequency hyperthermia using the newly-developed 'cooled-tip' needle has recently been proposed as a therapeutic modality for hepatocellular carcinoma (HCC). Herein we report our preliminary results on feasibility and effectiveness of the thermal ablation of mono- or pauci-focal hepatocellular carcinoma with the cooled-tip needle. We treated 15 cirrhotic patients (mean age 68.8 years; 12 males; 14 HCV-positive; 13 in Child's Class A and 2 in Class B) with 20 hepatocellular carcinoma nodules (mean diameter 28.1 mm; range 10-43 mm; nine lesions with diameter greater than 3 cm). None of the patients had portal thrombosis and/or extrahepatic spread. We used a radiofrequency generator (100 W of power) connected to a 18 g perfusion electrode needle with an exposed tip of 2-3 cm. The circuit was closed through a dispersive electrode positioned under the patient's thighs. A peristaltic pump infused a chilled (2-5 degrees C) saline solution to guarantee the continuous cooling of the needle tip. The needle was placed into target lesions under US guidance. The interventional procedure was carried out in general anesthesia without intubation. Dynamic helical CT was carried out 15-20 days after thermal ablation to assess therapeutic efficacy. In all, 38 areas of coagulation necrosis (at 1000-1200 mA for 10-15 min) were generated in 24 sessions in the 20 hepatocellular carcinoma nodules (mean 1.9 lesions per nodule and 1.2 sessions per nodule). Complete necrosis as assessed at dynamic CT (lack of enhancement during the arteriographic phase) was achieved in 75% of cases in a single session; after a second RF session success rate was 90% (18 out of 20 nodules). A self-limited pleurisy along with a 5-fold increase in transaminases occurred in one patient; a 3-fold elevation of transaminases was encountered in three other patients. During the follow-up (median 15 months) five patients had recurrent hepatocellular carcinoma with a 1-year disease free interval of 64%. Of the three recorded deaths, two were due to intrahepatic tumor diffusion. In our experience radiofrequency hyperthermia with the cooled-tip needle afforded an effective and safe percutaneous ablative method for HCC in cirrhosis and shortened treatment time.
Pillai, Anil K; Andring, Brice; Faulconer, Nicholas; Reis, Stephen P; Xi, Yin; Iyamu, Ikponmwosa; Suthpin, Patrick D; Kalva, Sanjeeva P
2016-08-01
To compare safety and effectiveness of intravascular ultrasound (US)-guided portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) creation with conventional TIPS technique. In this retrospective study, TIPS creation using intravascular US guidance in 55 patients was compared with conventional TIPS creation in 54 patients by 10 operators over a 3-year period. Operators were classified as experienced if they had performed ≥ 20 TIPS procedures at the beginning of the study period. Time to portal vein access, total radiation dose, and needle pass-related capsular perforation were recorded. Baseline demographic characteristics of patients were similar (P > .05). Mean time to portal venous access was 46 minutes ± 37 for conventional TIPS and 31 minutes ± 19 for intravascular US-guided TIPS (P = .007). Intravascular US guidance allowed significantly shorter times (48 min ± 30 vs 28 min ± 16; P = .01) to portal vein access among operators (n = 5) with limited experience but failed to achieve any significant time savings (44 min ± 43 vs 34 min ± 22; P = .89) among experienced operators (n = 5). Needle pass-related capsular perforation occurred in 17/54 (34%) patients with conventional TIPS and 5/55 (9%) patients with intravascular US-guided TIPS (P = .004). Radiation dose was 2,376 mGy ± 1,816 for conventional TIPS and 1,592 mGy ± 1,263 for intravascular US-guided TIPS (P = .004). Intravascular US-guided portal vein access during TIPS creation is associated with shorter portal vein access times, decreased needle pass-related capsular perforations, and reduced radiation dose. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
An Optical Actuation System and Curvature Sensor for a MR-compatible Active Needle
Ryu, Seok Chang; Quek, Zhan Fan; Renaud, Pierre; Black, Richard J.; Daniel, Bruce L.; Cutkosky, Mark R.
2015-01-01
A side optical actuation method is presented for a slender MR-compatible active needle. The needle includes an active region with a shape memory alloy (SMA) wire actuator, where the wire generates a contraction force when optically heated by a laser delivered though optical fibers, producing needle tip bending. A prototype, with multiple side heating spots, demonstrates twice as fast an initial response compared to fiber tip heating when 0.8 W of optical power is applied. A single-ended optical sensor with a gold reflector is also presented to measure the curvature as a function of optical transmission loss. Preliminary tests with the sensor prototype demonstrate approximately linear response and a repeatable signal, independent of the bending history. PMID:26509099
Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak
2015-11-01
Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (φ0.55 mm) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are 2.86 ± 1.14, 1.11 ± 0.14 and 1.94 ± 0.63 mm for case 1, case 2 and case 3, respectively. The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.
Çiğdem, Ünal Kantekin; Sevinç, Şahin; Esef, Bolat; Süreyya, Öztürk; Muzaffer, Gencer; Akif, Demirel
To investigate the differences in the number of squamous epithelial cells carried to the spinal canal by three different types of spinal needle tip of the same size. Patients were allocated into three groups (Group I, Group II, Group III). Spinal anesthesia was administered to Group I (n=50) using a 25G Quincke needle, to Group II (n=50) using a 25G pencil point spinal needle, and to Group III (n=50) using a non-cutting atraumatic needle with special bending. The first and third drops of cerebral spinal fluid (CSF) samples were taken from each patient and each drop was placed on a slide for cytological examination. Nucleated and non-nucleated squamous epithelial cells on the smear preparations were counted. There was statistically significant difference between the groups in respect to the number of squamous epithelial cells in the first drop (p<0.05). Group III had lower number of squamous epithelial cells in the first drop compared to that of Group I and Group II. Mean while Group I had higher number of squamous epithelial cells in the third drop compared to the other groups. The number of squamous epithelial cells in the first and third drops was statistically similar in each group respectively (p>0.05 for each group). In this study of different needle tips, it was seen that with atraumatic needle with special bending a significantly smaller number of cells were transported when compared to the Quincke tip needles, and with pencil point needles. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Sugar export limits size of conifer needles
NASA Astrophysics Data System (ADS)
Rademaker, Hanna; Zwieniecki, Maciej A.; Bohr, Tomas; Jensen, Kaare H.
2017-04-01
Plant leaf size varies by more than three orders of magnitude, from a few millimeters to over one meter. Conifer leaves, however, are relatively short and the majority of needles are no longer than 6 cm. The reason for the strong confinement of the trait-space is unknown. We show that sugars produced near the tip of long needles cannot be exported efficiently, because the pressure required to drive vascular flow would exceed the greatest available pressure (the osmotic pressure). This basic constraint leads to the formation of an inactive region of stagnant fluid near the needle tip, which does not contribute to sugar flow. Remarkably, we find that the size of the active part does not scale with needle length. We predict a single maximum needle size of 5 cm, in accord with data from 519 conifer species. This could help rationalize the recent observation that conifers have significantly smaller leaves than angiosperms, and provide a biophysical explanation for this intriguing difference between the two largest groups of plants.
New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchida, Barry T.; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Shimohira, Masashi
Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display themore » septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Safriel, Yair; Ang, Roberto; Ali, Muhammed
2008-03-15
Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualizedmore » using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered.« less
[The effect of needle type and immobilization on postspinal headache].
Hafer, J; Rupp, D; Wollbrück, M; Engel, J; Hempelmann, G
1997-10-01
Post-dural puncture headache (PDPH) is a significant complication of spinal anaesthesia. Diameter and tip of the needle as well as the patient's age have been proven to be important determinants. The question of whether post-operative recumbency can reduce the risk of PDPH has not been answered uniformly. And besides, some studies referring to this subject reveal methodical failures, for example, as to clear definition and exact documentation of post-operative immobilization. Furthermore, fine-gauge needles (26G or more) have not been investigated yet. The first aim of our study was therefore to examine the role of recumbency in the prevention of PDPH under controlled conditions using thin needles. Secondly, we wanted to confirm the reported prophylactic effect of needles with a modified, atraumatic tip (Whitacre and Atraucan) by comparing them to Quincke needles of identical diameter. Most of the former investigators compared Quincke with atraumatic needles of different size regardless of the known influence of the diameter on PDPH. In a prospective study we included 481 consecutive patients undergoing a total of 500 orthopaedic operations under spinal anaesthesia. The latter was performed in a standardized manner (patient sitting, midline approach, needle with parallel bevel direction), using four different needles allocated randomly (26-gauge and 27-gauge needles with Quincke tip, 26-gauge Atraucan and 27-gauge Whitacre cannula). Half of the patients were instructed to stay in bed for 24 h (horizontal position without raising head), the others to get up as early as possible. An anaesthesiologist visited the patients on the fourth postoperative day or later and questioned them about headache and duration of recumbency. Additionally, the patients had to fill out a questionnaire 1 week after surgery. Any postural headache was considered as PDPH. The four groups of different needles had homogeneous demographic characteristics (see Table 1). A total of 47 patients (9.4%) developed PDPH. The incidence was highest after puncture with a 26-gauge Quincke cannula (17.6%) with a significant difference compared to the other needles (see Table 2). PDPH incidence correlated well with increasing age and number of dural punctures, but showed no relation to sex, patient's history of headache or experience of the anaesthesiologist. Only about half of the patients (60.5%) followed the instructions regarding mobilization or recumbency. The duration of strict bed rest did not influence the development of PDPH: The overall incidence was 9.4% in the recumbency group and 8.8% in the group of early ambulation. In all, 45 patients suffered from ordinary not posture-related headache. The significantly higher incidence of PDPH after spinal anaesthesia with 26-gauge Quincke needles compared to the 27-gauge Quincke and the 26-gauge Atraucan group confirmed the importance of both needle diameter and design of its tip. The Atraucan cannula has not been examined in a controlled study (in comparison with Quincke needle of the same diameter) before. In accordance with other investigators we found patient's age and number of puncture attempts as additional predictors of PDPH. Consequent bed rest, however, was not able to reduce its incidence. Our studies reveal the poor compliance of patients with regard to mobilization/immobilization, a problem which possibly has not been considered enough in former studies examining the influence of bed rest on PDPH. Based on the literature and the present findings, we recommend using thin needles with atraumatic tips for spinal anaesthesia if possible. Recumbency presents an avoidable stress for patients as well as medical staff and should no longer be ordered.
Comparison of Spinal Needle Deflection in a Ballistic Gel Model.
Rand, Ethan; Christolias, George; Visco, Christopher; R Singh, Jaspal
2016-10-01
Percutaneous diagnostic and therapeutic procedures are commonly used in the treatment of spinal pain. The success of these procedures depends on the accuracy of needle placement, which is influenced by needle size and shape. The purpose of this study is to examine and quantify the deviation of commonly used spinal needles based on needle tip design and gauge, using a ballistic gel tissue simulant. Six needles commonly used in spinal procedures (Quincke, Short Bevel, Chiba, Tuohy, Hustead, Whitacre) were selected for use in this study. Ballistic gel samples were made in molds of two depths, 40mm and 80 mm. Each needle was mounted in a drill press to ensure an accurate needle trajectory. Distance of deflection was recorded for each needle. In comparing the mean deflection of 22 gauge needles of all types at 80 mm of depth, deflection was greatest among beveled needles [Short Bevel (9.96 ± 0.77 mm), Quincke (8.89 ± 0.17 mm), Chiba (7.71 ± 1.16 mm)], moderate among epidural needles [Tuohy (7.64 ± 0.16 mm) and least among the pencil-point needles [Whitacre (0.73 ± 0.34 mm)]. Increased gauge (25 g) led to a significant increase in deflection among beveled needles. The direction of deflection was away from the bevel with Quincke, Chiba and Short Beveled needles and toward the bevel of the Tuohy and Hustead needles. Deflection of the Whitacre pencil-point needle was minimal. There is clinical utility in knowing the relative deflection of various needle tips. When a procedure requires a needle to be steered around obstacles, or along non-collinear targets, the predictable and large amount of deflection obtained through use of a beveled spinal needle may prove beneficial.
Comparison of Spinal Needle Deflection in a Ballistic Gel Model
Rand, Ethan; Christolias, George; Visco, Christopher; R. Singh, Jaspal
2016-01-01
Background Percutaneous diagnostic and therapeutic procedures are commonly used in the treatment of spinal pain. The success of these procedures depends on the accuracy of needle placement, which is influenced by needle size and shape. Objectives The purpose of this study is to examine and quantify the deviation of commonly used spinal needles based on needle tip design and gauge, using a ballistic gel tissue simulant. Materials and Methods Six needles commonly used in spinal procedures (Quincke, Short Bevel, Chiba, Tuohy, Hustead, Whitacre) were selected for use in this study. Ballistic gel samples were made in molds of two depths, 40mm and 80 mm. Each needle was mounted in a drill press to ensure an accurate needle trajectory. Distance of deflection was recorded for each needle. Results In comparing the mean deflection of 22 gauge needles of all types at 80 mm of depth, deflection was greatest among beveled needles [Short Bevel (9.96 ± 0.77 mm), Quincke (8.89 ± 0.17 mm), Chiba (7.71 ± 1.16 mm)], moderate among epidural needles [Tuohy (7.64 ± 0.16 mm) and least among the pencil-point needles [Whitacre (0.73 ± 0.34 mm)]. Increased gauge (25 g) led to a significant increase in deflection among beveled needles. The direction of deflection was away from the bevel with Quincke, Chiba and Short Beveled needles and toward the bevel of the Tuohy and Hustead needles. Deflection of the Whitacre pencil-point needle was minimal. Conclusions There is clinical utility in knowing the relative deflection of various needle tips. When a procedure requires a needle to be steered around obstacles, or along non-collinear targets, the predictable and large amount of deflection obtained through use of a beveled spinal needle may prove beneficial. PMID:27847693
Needle twins and right-angled twins in minerals: comparison between experiment and theory
Salje, E.K.H.; Buckley, A.; Van Tendeloo, G.; Ishibashi, Y.; Nord, G.L.
1998-01-01
Transformation twinning in minerals forms isolated twin walls, intesecting walls with corner junctions, and wedge-shaped twins as elements of hierarchical patterns. When cut perpendicular to the twin walls, the twins have characteristic shapes, right-angled and needle-shaped wall traces, which can be observed by transmission electron microscopy or by optical microscopy. Theoretical geometries of wall shapes recently derived for strain-related systems should hold for most displacive and order-disorder type phase transitions: 1) right-angled twins show curved junctions; 2) needle-shaped twins contain flat wall segments near the needle tip if the elastic behaviour of the mineral is dominated by its anisotroyp; 3) additional bending forces and pinning effects lead to curved walls near the junction that make the needle tip appear more blunt. Bent right-angled twins were analyzed in Gd2(MoO4)3. Linear needle tips were found in WO3, [N(CH3)4]2.ZnBr4 CrAl, BiVO4, GdBa2Cu3O7, and PbZrO. Parabolic tips occur in K2Ba(NO2)4, and GeTe whereas exponential curvatures appear in BaTiO3, KSCN, Pb3(PO4)2, CaTiO3, alkali feldspars, YBa2Cu3O7, and MnAl. The size and shape of the twin microstructure relates to its formation during the phase transition and the subsequent annealing history. The mobility of the twin walls after formation depends not only on the thermal activation but also on the structure of the wall, which may be pinned to impurities on a favorable structural site. Depinnign energies are often large compared with thermal energies for diffusion. This leads to kinetic time scales for twin coarsening that are comparable to geological time scales. Therefore, transformation twins that exhibit needle domains not only indicate that the mineral underwent a structural phase transition but also contain information about its subsequent geological history.
Postmyelography headache rates with Whitacre versus Quincke 22-gauge spinal needles.
Peterman, S B
1996-09-01
To compare the postdural puncture headache (PDPH) rates after myelography with use of 22-gauge Whitacre (blunt tip) versus standard 22-gauge Quincke (bevel-tip) spinal needles. At myelography, 340 patients were randomly assigned to one of two groups in which either the Whitacre (167 patients) or the Quincke (173 patients) needle was used. Follow-up was at 48 hours and at 4 days after the procedure. Crude and adjusted Whitacre/PDPH odds ratios and risk ratios were calculated. The crude Whitacre needle PDPH risk was 9.6%, and the crude Quincke needle PDPH risk was 15.6%. The absolute risk difference was 6.0% with a 95% confidence interval of -0.98% and 13.04%. The adjusted Whitacre/PDPH odds ratio was 0.492 with a 95% confidence interval of 0.241 and 1.003. The Whitacre needle group had a statistically significantly lower PDPH severity grade (P = .0151), similar PDPH duration, and more technical difficulty with the needle. The Whitacre needle is associated with an equal or lower PDPH risk; the lack of statistical significance is most likely related to sample size. Further study is necessary to determine whether the decreased PDPH rate justifies the added difficulty associated with use of the Whitacre needle.
NASA Astrophysics Data System (ADS)
Sekimoto, K.; Takayama, M.
2008-12-01
The dependence of negative ion formation on the inhomogeneous electric field strength in atmospheric pressure negative corona discharge with point-to-plane electrodes has been described. The distribution of negative ions HO-, NOx - and COx - and their abundances on the plane electrode was obtained with a mass spectrometer. The ion distribution on the plane was divided into two regions, the center region on the needle axis and peripheral region occurring the dominant NOx - and COx - ions and HO- ion, respectively. The calculated electric field strength in inhomogeneous electric field established on the needle tip surface suggested that the abundant formation of NOx - and COx - ions and HO- ion is attributed to the high field strength at the tip apex region over 108 Vm-1 and the low field strength at the tip peripheral region of the order of 107 Vm-1, respectively. The formation of HO-, NOx - and COx - has been discussed from the standpoint of negative ion evolution based on the thermochemical reaction and the kinetic energy of electron emitted from the needle tip.
A new needle on the block: EchoTip ProCore endobronchial ultrasound needle
Dincer, H Erhan; Andrade, Rafael; Zamora, Felix; Podgaetz, Eitan
2016-01-01
Endobronchial ultrasound has become the first choice standard of care procedure to diagnose benign or malignant lesions involving mediastinum and lung parenchyma adjacent to the airways owing to its characteristics of being real-time and minimally invasive. Although the incidence of lung cancer has been decreasing, it is and will be the leading cause of cancer-related mortality in the next few decades. When compared to other cancers, lung cancer kills more females than breast and colon cancers combined and more males than colon and prostate cancers combined. The type of lung cancer has changed in recent decades and adenocarcinoma has become the most frequent cell type. Prognosis of lung cancer depends upon the cell type and the staging at the time of diagnosis. The cell type and molecular characteristics of adenocarcinoma may allow individualized targeted treatment. Other malignant conditions in the mediastinum and lung (eg, metastatic lung cancers and lymphoma) can be biopsied using endobronchial ultrasound needles. Endobronchial ultrasound needle biopsies provides mostly cytology specimens due to its small sizes of needles (22 gauge or larger) which may not give enough tissue to make a definitive diagnosis in malignant (eg, lymphoma) or benign conditions (eg, sarcoidosis). EchoTip ProCore endobronchial needle released in early 2014 provides histologic biopsy material. Larger tissue biopsies may potentially provide a higher diagnostic yield and it eliminates mediastinoscopy or other surgical interventions. Here we aim to review bronchoscopic approach in the diagnosis of mediastinal lesions with emphasis of EchoTip ProCore needles. PMID:27099535
A portable integrated system to control an active needle
NASA Astrophysics Data System (ADS)
Konh, Bardia; Motalleb, Mahdi; Ashrafiuon, Hashem
2017-04-01
The primary objective of this work is to introduce an integrated portable system to operate a flexible active surgical needle with actuation capabilities. The smart needle uses the robust actuation capabilities of the shape memory alloy wires to drastically improve the accuracy of in medical procedures such as brachytherapy. This, however, requires an integrated system aimed to control the insertion of the needle via a linear motor and its deflection by the SMA wire in real-time. The integrated system includes a flexible needle prototype, a Raspberry Pi computer, a linear stage motor, an SMA wire actuator, a power supply, electromagnetic tracking system, and various communication supplies. The linear stage motor guides the needle into tissue. The power supply provides appropriate current to the SMA actuator. The tracking system measures tip movement for feedback, The Raspberry Pi is the central tool that receives the tip movement feedback and controls the linear stage motor and the SMA actuator via the power supply. The implemented algorithms required for communication and feedback control are also described. This paper demonstrates that the portable integrated system may be a viable solution for more effective procedures requiring surgical needles.
Smart surgical needle actuated by shape memory alloys for percutaneous procedures
NASA Astrophysics Data System (ADS)
Konh, Bardia
Background: Majority of cancer interventions today are performed percutaneously using needle-based procedures, i.e. through the skin and soft tissue. Insufficient accuracy using conventional surgical needles motivated researchers to provide actuation forces to the needle's body for compensating the possible errors of surgeons/physicians. Therefore, active needles were proposed recently where actuation forces provided by shape memory alloys (SMAs) are utilized to assist the maneuverability and accuracy of surgical needles. This work also aims to introduce a novel needle insertion simulation to predict the deflection of a bevel tip needle inside the tissue. Methods: In this work first, the actuation capability of a single SMA wire was studied. The complex response of SMAs was investigated via a MATLAB implementation of the Brinson model and verified via experimental tests. The material characteristics of SMAs were simulated by defining multilinear elastic isothermal stress-strain curves. Rigorous experiments with SMA wires were performed to determine the material properties as well as to show the capability of the code to predict a stabilized SMA transformation behavior with sufficient accuracy. The isothermal stress-strain curves of SMAs were simulated and defined as a material model for the Finite Element Analysis of the active needle. In the second part of this work, a three-dimensional finite element (FE) model of the active steerable needle was developed to demonstrate the feasibility of using SMA wires as actuators to bend the surgical needle. In the FE model, birth and death method of defining boundary conditions, available in ANSYS, was used to achieve the pre-strain condition on SMA wire prior to actuation. This numerical model was validated with needle deflection experiments with developed prototypes of the active needle. The third part of this work describes the design optimization of the active using genetic algorithm aiming for its maximum flexibility. Design parameters influencing the steerability include the needle's diameter, wire diameter, pre-strain, and its offset from the needle. A simplified model was developed to decrease the computation time in iterative analyses of the optimization algorithm. In the fourth part of this work a design of an active needling system was proposed where actuation forces of SMAs as well as shape memory polymers (SMPs) were incorporated. SMP elements provide two major additional advantages to the design: (i) recovery of the SMP's plastic deformation by heating the element above its glass transition temperature, and (ii) achieving a higher needle deflection by having a softer stage of SMP at higher temperatures with less amount of actuation force. Finally, in the fifth and last part of this study, an Arbitrary-Lagrangian-Eulerian formulation in LS-DYNA software was used to model the solid-fluid interactions between the needle and tissue. A 150mm long needle was considered to bend within the tissue due to the interacting forces on its asymmetric bevel tip. Some additional assumptions were made to maintain a reasonable computational time, with no need of parallel processing, while having practical accuracies. Three experimental tests of needle steering in a soft phantom were performed to validate the simulation. Results: The finite element model of the active needle was first validated experimentally with developed prototypes. Several design parameters affecting the needle's deflection such as the needle's Young's modulus, the SMA's pre-strain and its offset from the neutral axis of the cannula were studied using the FE model. Then by the integration of the SMA characteristics with the automated optimization schemes an improved design of the active needle was obtained. Real-time experiments with different prototypes showed that the quickest response and the maximum deflection were achieved by the needle with two sections of actuation compared to a single section of actuation. Also the feasibility of providing actuation forces using both SMAs and SMPs for the surgical needle was demonstrated in this study. The needle insertion simulation was validated while observing less than 10% deviation between the estimated amount of needle deflection by the simulation and by the experiments. Using this model the effect of needle diameter and its bevel tip angle on the final shape of the needle was investigated. Conclusion: The numerical and experimental studies of this work showed that a highly maneuverable active needle can be made using the actuation of multiple SMA wires in series. To maneuver around the anatomical obstacles of the human body and reach the target location, thin sharp needles are recommended as they would create a smaller radius of curvature. The insertion model presented in this work is intended to be used as a base structure for path planning and training purposes for future studies. (Abstract shortened by UMI.).
Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H
2018-02-01
We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morawski, Ireneusz; Institute of Experimental Physics, University of Wrocław, pl. M. Borna 9, 50-204 Wrocław; Spiegelberg, Richard
A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. Themore » high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations.« less
Design and evaluation of an intraocular B-scan OCT-guided 36-gauge needle
NASA Astrophysics Data System (ADS)
Shen, Jin H.; Joos, Karen M.
2015-03-01
Optical coherence tomography imaging is widely used in ophthalmology and optometry clinics for diagnosing retinal disorders. External microscope-mounted OCT operating room systems have imaged retinal changes immediately following surgical manipulations. However, the goal is to image critical surgical maneuvers in real time. External microscope-mounted OCT systems have some limitations with problems tracking constantly moving intraocular surgical instruments, and formation of absolute shadows by the metallic surgical instruments upon the underlying tissues of interest. An intraocular OCT-imaging probe was developed to resolve these problems. A disposable 25-gauge probe tip extended beyond the handpiece, with a 36-gauge needle welded to a disposable tip with its end extending an additional 3.5 mm. A sealed 0.35 mm diameter GRIN lens protected the fiber scanner and focused the scanning beam at a 3 to 4 mm distance. The OCT engine was a very high-resolution spectral-domain optical coherence tomography (SDOCT) system (870 nm, Bioptigen, Inc. Durham, NC) which produced 2000 A-scan lines per B-scan image at a frequency of 5 Hz with the fiber optic oscillations matched to this frequency. Real-time imaging of the needle tip as it touched infrared paper was performed. The B-scan OCT-needle was capable of real-time performance and imaging of the phantom material. In the future, the B-scan OCT-guided needle will be used to perform sub-retinal injections.
Yun, Joho; Kim, Jinhwan; Lee, Jong-Hyun
2017-11-28
We have introduced a fabrication method for electrical impedance spectroscopy (EIS)-on-a-needle (EoN: EIS-on-a-needle) to locate target tissues in the body by measuring and analyzing differences in the electrical impedance between dissimilar biotissues. This paper describes the fabrication method of fine interdigitated electrodes (IDEs) at the tip of a hypodermic needle using a photoresist spray coating and flexible film photomask in the photolithography process. A polyethylene terephthalate (PET) heat shrink tube (HST) with a wall thickness of 25 µm is employed as the insulation and passivation layer. The PET HST shows a higher mechanical durability compared with poly(p-xylylene) polymers, which have been widely used as a dielectric coating material. Furthermore, the HST shows good chemical resistance to most acids and bases, which is advantageous for limiting chemical damage to the EoN. The use of the EoN is especially preferred for the characterization of chemicals/biomaterials or fabrication using acidic/basic chemicals. The fabricated gap and width of the IDEs are as small as 20 µm, and the overall width and length of the IDEs are 400 µm and 860 µm, respectively. The fabrication margin from the tip (distance between the tip of hypodermic needle and starting point of the IDEs) of the hypodermic needle is as small as 680 µm, which indicates that unnecessarily excessive invasion into biotissues can be avoided during the electrical impedance measurement. The EoN has a high potential for clinical use, such as for thyroid biopsies and anesthesia drug delivery in a spinal space. Further, even in surgery that involves the partial resection of tumors, the EoN can be employed to preserve as much normal tissue as possible by detecting the surgical margin (normal tissue that is removed with the surgical excision of a tumor) between the normal and lesion tissues.
Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle
NASA Astrophysics Data System (ADS)
Choi, Jae; Popa, Teo; Gruionu, Lucian
2009-02-01
Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.
Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.
Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G
2013-09-01
To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Waknis, Vrushali; Chu, Elza; Schlam, Roxana; Sidorenko, Alexander; Badawy, Sherif; Yin, Shawn; Narang, Ajit S
2014-01-01
The molecular basis of crystal surface adhesion leading to sticking was investigated by exploring the correlation of crystal adhesion to oxidized iron coated atomic force microscope (AFM) tips and bulk powder sticking behavior during tableting of two morphologically different crystals of a model drug, mefenamic acid (MA), to differences in their surface functional group orientation and energy. MA was recrystallized into two morphologies (plates and needles) of the same crystalline form. Crystal adhesion to oxidized iron coated AFM tips and bulk powder sticking to tablet punches was assessed using a direct compression formulation. Surface functional group orientation and energies on crystal faces were modeled using Accelrys Material Studio software. Needle-shaped morphology showed higher sticking tendency than plates despite similar particle size. This correlated with higher crystal surface adhesion of needle-shaped morphology to oxidized iron coated AFM probe tips, and greater surface energy and exposure of polar functional groups. Higher surface exposure of polar functional groups correlates with higher tendency to stick to metal surfaces and AFM tips, indicating involvement of specific polar interactions in the adhesion behavior. In addition, an AFM method is identified to prospectively assess the risk of sticking during the early stages of drug development.
Rodgers, Jessica Robin; Surry, Kathleen; Leung, Eric; D'Souza, David; Fenster, Aaron
2017-05-01
Treatment for gynecologic cancers, such as cervical, recurrent endometrial, and vaginal malignancies, commonly includes external-beam radiation and brachytherapy. In high-dose-rate (HDR) interstitial gynecologic brachytherapy, radiation treatment is delivered via hollow needles that are typically inserted through a template on the perineum with a cylinder placed in the vagina for stability. Despite the need for precise needle placement to minimize complications and provide optimal treatment, there is no standard intra-operative image-guidance for this procedure. While some image-guidance techniques have been proposed, including magnetic resonance (MR) imaging, X-ray computed tomography (CT), and two-dimensional (2D) transrectal ultrasound (TRUS), these techniques have not been widely adopted. In order to provide intra-operative needle visualization and localization during interstitial brachytherapy, we have developed a three-dimensional (3D) TRUS system. This study describes the 3D TRUS system and reports on the system validation and results from a proof-of-concept patient study. To obtain a 3D TRUS image, the system rotates a conventional 2D endocavity transducer through 170 degrees in 12 s, reconstructing the 2D frames into a 3D image in real-time. The geometry of the reconstruction was validated using two geometric phantoms to ensure the accuracy of the linear measurements in each of the image coordinate directions and the volumetric accuracy of the system. An agar phantom including vaginal and rectal canals, as well as a model uterus and tumor, was designed and used to test the visualization and localization of the interstitial needles under idealized conditions by comparing the needles' positions between the 3D TRUS scan and a registered MR image. Five patients undergoing HDR interstitial gynecologic brachytherapy were imaged using the 3D TRUS system following the insertion of all needles. This image was manually, rigidly registered to the clinical postinsertion CT scan based on the vaginal cylinder of the needle template. The positions of the tips and the trajectory of the needle paths were compared between the modalities. The observed geometric errors of the system were ≤ 0.3 mm in each of the three coordinate planes of the 3D US image and the mean measured volumetric error was 0.10 cm 3 . In the phantom study, the mean needle tip difference was 1.54 ± 0.71 mm and the mean trajectory difference was 0.94 ± 0.89 degrees (n = 14). In the in vivo study, a total of 73 needles were placed, of which 88% of needles were visible and 79% of tips were identifiable in the 3D TRUS images. Six of the nine needles that were not visible were due to shadowing artifacts created by the presence of the vaginal cylinder of the needle template. The mean distance between corresponding needle tips in the two modalities was 3.82 ± 1.86 mm and the mean trajectory difference was 3.04 ± 1.63 degrees for the five patients. In this proof-of-concept study, the 3D TRUS system allowed for localization of needles not obscured by shadowing artifacts, providing a method for visualizing needles intra-operatively during HDR interstitial brachytherapy of gynecologic cancers and providing the potential for 3D image-guidance. © 2017 American Association of Physicists in Medicine.
Self-organized pattern on the surface of a metal anode in low-pressure DC discharge
NASA Astrophysics Data System (ADS)
Yaqi, YANG; Weiguo, LI
2018-03-01
Self-organization phenomena on the surface of a metal electrode in low-pressure DC discharge is studied. In this paper, we carry out laboratory investigations of self-organization in a low-pressure test platform for 100-200 mm rod-plane gaps with a needle tip, conical tip and hemispherical tip within 1-10 kPa. The factors influencing the pattern profile are the pressure value, gap length and shape of the electrode, and a variety of pattern structures are observed by changing these factors. With increasing pressure, first the pattern diameter increases and then decreases. With the needle tip, layer structure, single-ring structure and double-ring structure are displayed successively with increasing pressure. With the conical tip, the ring-like structure gradually forms separate spots with increasing pressure. With the hemispherical tip, there are anode spots inside the ring structure. With the increase of gap length, the diameter of the self-organized pattern increases and the profile of the pattern changes. The development process of the pattern contains three key stages: pattern enlargement, pattern stabilization and pattern shrink.
Augmented Reality-Guided Lumbar Facet Joint Injections.
Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda
2018-05-08
The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P < 0.001 for both readers). Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.
NASA Astrophysics Data System (ADS)
Sakiyama, Y.; Graves, D. B.; Stoffels, E.
2008-05-01
We present a comparison of a finite element analysis of the atmospheric pressure RF-excited plasma needle interacting with different surfaces with corresponding experimental observations of light emission spatial profiles. The gas used is helium with 1 ppm nitrogen as an impurity. The needle has a point-to-plane geometry with a radius of 30 µm at the tip and an inter-electrode gap of 1 mm. We employ a fluid model in two-dimensional axisymmetric coordinates. Our simulation results indicate that the plasma structure strongly depends on the electrical properties of the treated surface as well as the discharge mode. In the lower power corona mode with a dielectric surface, the plasma is confined near the needle tip. As a result, particle fluxes to the dielectric surface are relatively low and follow a Gaussian-like radial profile. In the higher power glow mode with a dielectric surface, the particle fluxes to the surface are orders of magnitude higher and the spatial distribution of the particle fluxes becomes radially more uniform due to a uniform ionization layer just above the treated surface. When a conductive plate replaces the dielectric surface in the glow mode, a quite intense ionization spot appears near the surface closest to the needle tip. Consequently, the particle fluxes to the surface peak near the symmetry axis under these conditions. These simulation results are validated by experimental observation of light emission spatial profiles.
Design of an actively controlled steerable needle with tendon actuation and FBG-based shape sensing.
van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J
2015-06-01
This work presents a new steerable needle to facilitate active steering toward predefined target locations. It focuses on mechanical aspects and design choices in relation to the observed response in a tissue phantom. Tip steering with two rotational degrees of freedom was achieved by a tendon actuated ball joint mechanism. During insertion, the flexible cannula bends as a result of asymmetric tip-tissue interaction forces. The stylet was equipped with fiber Bragg gratings to measure the needle shape and tip position during use. A PI-controller was implemented to facilitate steering to predefined targets. During the validation study, nine targets were defined at a depth of 100 mm below the gelatin surface. One was located below the insertion point, the others at a radial offset of 30 mm in each of the eight principle steering directions. Per location, six repetitions were performed. The targeting accuracy was 6.2 ± 1.4 mm (mean ± std). The steering precision was 2.6 ± 1.1 mm. The ability to steer with this new needle steering approach is presented and the mechanical characteristics are discussed for this representative subset of steering directions. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Virtual remote center of motion control for needle placement robots.
Boctor, Emad M; Webster, Robert J; Mathieu, Herve; Okamura, Allison M; Fichtinger, Gabor
2004-01-01
We present an algorithm that enables percutaneous needle-placement procedures to be performed with unencoded, unregistered, minimally calibrated robots while removing the constraint of placing the needle tip on a mechanically enforced Remote Center of Motion (RCM). The algorithm requires only online tracking of the surgical tool and a five-degree-of-freedom (5-DOF) robot comprising three prismatic DOF and two rotational DOF. An incremental adaptive motion control cycle guides the needle to the insertion point and also orients it to align with the target-entry-point line. The robot executes RCM motion without having a physically constrained fulcrum point. The proof-of-concept prototype system achieved 0.78 mm translation accuracy and 1.4 degrees rotational accuracy (this is within the tracker accuracy) within 17 iterative steps (0.5-1 s). This research enables robotic assistant systems for image-guided percutaneous procedures to be prototyped/constructed more quickly and less expensively than has been previously possible. Since the clinical utility of such systems is clear and has been demonstrated in the literature, our work may help promote widespread clinical adoption of this technology by lowering system cost and complexity.
Fredrickson, Michael J
2008-01-01
Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of =2 (scale, 0-10). In 57% of patients, a muscle response was not elicited. An ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
Corona-glow transition in the atmospheric pressure RF-excited plasma needle
NASA Astrophysics Data System (ADS)
Sakiyama, Y.; Graves, D. B.
2006-08-01
We present clear evidence of two different discharge modes of the atmospheric pressure RF-excited plasma needle and the transition mechanism by the finite element method. The gas used is helium with 0.1% nitrogen addition. The needle has a point-to-plane geometry with a radius of 30 µm at the tip, 150 µm at the base and an inter-electrode gap of 1 mm. We employ the one-moment fluid model with the local field approximation. Our simulation results indicate that the plasma needle operates as a corona discharge at low power and that the discharge mode transitions to a glow discharge at a critical power. The discharge power increases but the discharge voltage drops abruptly by a factor of about 2 in the corona-glow transition. The plasma density and ionization is confined near the needle tip in corona-mode while it spreads back along the needle surface in glow-mode. The corona-glow transition is also characterized by a dramatic decrease in sheath thickness and an order of magnitude increase in plasma density and volume-averaged ionization. The transition is observed whether or not secondary electron emission is included in the model, and therefore we suggest that this is not an α -γ transition.
Electron Microscopy of Dural and Arachnoid Disruptions After Subarachnoid Block.
Reina, Miguel Angel; Puigdellívol-Sánchez, Anna; Gatt, Stephen P; De Andrés, José; Prats-Galino, Alberto; van Zundert, André
It has been customary to attribute postdural puncture headache (PDPH) incidence and severity to size and nature of the dural hole produced during major neuraxial blockade or diagnostic dural puncture. Needle orientation in relation to the direction of dural fibers was thought to be of importance because of the propensity for horizontal bevel placement to cause cutting rather than splitting of the dural fibers. In vitro punctures of stringently quality-controlled human dural sac specimens were obtained with 27-gauge (27G) Whitacre needle (n = 33), with 29G Quincke used parallel to the spinal axis (n = 30), and with 29G Quincke in perpendicular approach (n = 40). The samples were studied with a scanning electron microscope, and the perimeter, appearance, and area (%) of the lesion were calculated. When using small 27G to 29G needles, neither needle tip characteristics nor needle orientation had a substantial bearing on the damage to dural fibers in the dural lesion. Of ultimate importance was the characteristic and size of the hole in the arachnoid. Arachnoid layer lesions produced by different types of spinal needles were not markedly different. Accepted theories of the etiology of PDPH need to be revised. This article marks the first time that arachnoid layer damage has been quantified. Dural fibers tend to have sufficient "memory" to close back the hole created by a spinal needle, whereas arachnoid has diminished capacity to do so. The pathogenesis of PDPH and its resolution algorithm are a far more complex process that involves many more "stages" of development than hitherto imagined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego
PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNBmore » with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.« less
NASA Astrophysics Data System (ADS)
Date, Kumi; Ishigure, Takaaki
2017-02-01
Polymer optical waveguides with graded-index (GI) circular cores are fabricated using the Mosquito method, in which the positions of parallel cores are accurately controlled. Such an accurate arrangement is of great importance for a high optical coupling efficiency with other optical components such as fiber ribbons. In the Mosquito method that we developed, a core monomer with a viscous liquid state is dispensed into another liquid state monomer for cladding via a syringe needle. Hence, the core positions are likely to shift during or after the dispensing process due to several factors. We investigate the factors, specifically affecting the core height. When the core and cladding monomers are selected appropriately, the effect of the gravity could be negligible, so the core height is maintained uniform, resulting in accurate core heights. The height variance is controlled in +/-2 micrometers for the 12 cores. Meanwhile, larger shift in the core height is observed when the needle-tip position is apart from the substrate surface. One of the possible reasons of the needle-tip height dependence is the asymmetric volume contraction during the monomer curing. We find a linear relationship between the original needle-tip height and the core-height observed. This relationship is implemented in the needle-scan program to stabilize the core height in different layers. Finally, the core heights are accurately controlled even if the cores are aligned on various heights. These results indicate that the Mosquito method enables to fabricate waveguides in which the cores are 3-dimensionally aligned with a high position accuracy.
Day surgery for vocal fold lesions using a double-bent 60-mm Cathelin needle.
Toyomura, Fumimasa; Tokashiki, Ryoji; Hiramatsu, Hiroyuki; Tsukahara, Kiyoaki; Motohashi, Ray; Sakurai, Eriko; Nomoto, Masaki; Suzuki, Mamoru
2014-11-01
Day surgery for vocal cord lesions overcomes the disadvantages of laryngomicrosurgery under general anesthesia. We present our experience with treatment of vocal fold lesions using a long double-bend Cathelin needle that can access all parts of the vocal cords. A 23G, 60-mm-long Cathelin needle was bent twice by 45(o) at a distance of 1 and 2 cm from the tip, and was attached to a syringe. Under topical anesthesia and nasal endoscopy of the laryngopharynx, the needle was inserted percutaneously perpendicular to the skin, the direction of insertion being altered when the bends in the needle reached the skin surface. This allows the tip of the needle to access all parts of the glottis, allowing the performance of procedures such as biopsies, excision of lesions, and injection into the vocal folds. Between January 2011 and December 2013, we used this technique to perform vocal fold procedures in 566 patients presenting for treatment of spasmodic dysphonia (412 cases, 73 %) and other vocal fold lesions. Only minor complications, such as hematoma (3 patients, 0.5 %) and slight bleeding from the puncture site in the epiglottic vallecula (all patients, 100 %), which ceased spontaneously within 10 min, were seen. Erroneous puncture occurred in three patients (0.5 %) and the puncture had to be repeated in 38 patients (6.7 %). The procedure was completed successfully in all cases (100 %). Surgery for vocal fold lesions under topical anesthesia using our double-bend Cathelin needle technique is simple, safe, and useful.
Viewing a needle pricking a hand that you perceive as yours enhances unpleasantness of pain.
Höfle, Marion; Hauck, Michael; Engel, Andreas K; Senkowski, Daniel
2012-05-01
"Don't look and it won't hurt" is commonly heard advice when receiving an injection, which implies that observing needle pricks enhances pain perception. Throughout our lives, we repeatedly learn that sharp objects cause pain when penetrating our skin, but situational expectations, like information given by the clinician prior to an injection, may also influence how viewing needle pricks affects forthcoming pain. How both previous experiences and acute situational expectations related to viewing needle pricks modulate pain perception is unknown. We presented participants with video clips of a hand perceived as their own being either pricked by a needle or touched by a Q-tip, while concurrently applying painful or nonpainful electrical stimuli. Intensity and unpleasantness ratings, as well as pupil dilation responses, were monitored. Effects of situational expectations about the strength of electrical stimuli were investigated by manipulating the contingency between clips and electrical stimuli across experimental blocks. Participants were explicitly informed about the contingency. Intensity ratings of electrical stimuli were higher when a clip was associated with expectation of painful compared to nonpainful stimuli, suggesting that situational expectations about forthcoming pain bias perceived intensity. Unpleasantness ratings and pupil dilation responses were higher when participants viewed a needle prick, compared to when they viewed a Q-tip touch, suggesting that previous experiences with viewing needle pricks primarily act upon perceived unpleasantness. Thus, remote painful experiences with viewing needle pricks, together with information given prior to an injection, differentially shape the impact of viewing a needle prick on pain perception. Copyright © 2012 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Teleoperated master-slave needle insertion.
Abolhassani, Niki; Patel, Rajni V
2009-12-01
Accuracy of needle tip placement and needle tracking in soft tissue are of particular importance in many medical procedures. In recent years, developing autonomous and teleoperated systems for needle insertion has become an active area of research. In this study, needle insertion was performed using a master-slave set-up with multi-degrees of freedom. The effect of force feedback on the accuracy of needle insertion was investigated. In addition, this study compared autonomous, teleoperated and semi-autonomous needle insertion. The results of this study show that incorporation of force feedback can improve teleoperated needle insertion. However, autonomous and semi-autonomous needle insertions, which use feedback from a deflection model, provide significantly better performance. Development of a haptic master-slave needle insertion system, which is capable of performing some autonomous tasks based on feedback from tissue deformation and needle deflection models, can improve the performance of autonomous robotics-based insertions as well as non-autonomous teleoperated manual insertions. Copyright (c) 2009 John Wiley & Sons, Ltd.
Safety of Lumbar Puncture Procedures in Patients with Alzheimer's Disease
Peskind, E.; Nordberg, A.; Darreh-Shori, T.; Soininen, H.
2014-01-01
Changes in cerebrospinal fluid (CSF) biomarkers are representative of biochemical changes in the brain. Collection of CSF by lumbar puncture (LP) is essential for biomarker analysis, which is important for research in neurodegenerative disorders. However, LP for research purposes has been controversial due to a reported high incidence of severe LP headache when using standard 18g or 20g Quincke needles with a beveled cutting tip. A procedural safety analysis was performed using the database of a multicenter, 13-week study of CSF cholinesterase activity. A 24g Sprotte atraumatic needle was used to collect CSF at baseline and at Week 13 from 63 older patients with mild to moderate Alzheimer's disease. There was a < 2% LP headache incidence, and a favorable safety profile was reported. In conclusion, LP performed with a 24g Sprotte atraumatic needle (blunt, “bullet” tip) was a well-tolerated procedure, with good acceptability. PMID:19519311
NASA Astrophysics Data System (ADS)
Guan, Dongshi; Charlaix, Elisabeth; Qi, Robert Z.; Tong, Penger
2017-10-01
Imaging of surface topography and elasticity of living cells can provide insight into the roles played by the cells' volumetric and mechanical properties and their response to external forces in regulating the essential cellular events and functions. Here, we report a unique technique of noncontact viscoelastic imaging of live cells using atomic force microscopy (AFM) with a long-needle glass probe. Because only the probe tip is placed in a liquid medium near the cell surface, the AFM cantilever in air functions well under dual-frequency modulation, retaining its high-quality resonant modes. The probe tip interacts with the cell surface through a minute hydrodynamic flow in the nanometer-thin gap region between them without physical contact. Quantitative measurements of the cell height, volume, and Young's modulus are conducted simultaneously. The experiment demonstrates that the long-needle AFM has a wide range of applications in the study of cell mechanics.
Production of needle-type liquid-metal ion sources and their application in a scanning ion muscope
NASA Astrophysics Data System (ADS)
Knapp, Helmut; Rübesame, Detlef; Niedrig, Heinz
1991-07-01
A tungsten wire is electrochemically etched in NaOH to produce tip radii of 4-10 μm for use in liquid-metal ion sources (LMIS). To ensure complete wetting of the needle with the liquid metal (Sn, Ga), the needle has to be annealed at 800-1000°C by electron bombardment in a vacuum. It is then immediately dipped into the liquid metal in the same vacuum chamber. An anode prepared in this way is part of a triode system, followed by an octupole stigmator, an electrostatic einzel lens and the scanning unit. Upon application of a high voltage the liquid metal will form a Taylor cone at the needle tip. In the resulting high electrical field ions are extracted through field evaporation. Typical beam current and spot size values during scanning ion muscope (SIM) operation are 2.5 μA and 10 μm respectively. An Everhart-Thornley detector and a quadrupole mass spectrometer are available to allow analysis of secondary particles emitted from the target.
Discrimination accuracy between real and sham press needles in the hands.
Kim, Sungha; Lee, Sanghun; Choi, Sunmi; Park, Jeonghwan; Kim, Sungchul
2015-08-01
To evaluate the blinding effectiveness of a modified blunt sham press needle on the basis of the ability of subjects to discriminate between real and sham acupuncture needles compared with their discrimination ability based on pure guessing, and to define differences between senses (touch and vision) in the rates of correctly identified needles. Sixty-three healthy students and staff members were recruited through convenience sampling. First, real or sham acupuncture was randomly administered to the left LI4 point while subjects could not observe the needle tip. A real or sham needle tip was then shown to the subjects. Finally, a random combination of real or sham acupuncture needles were randomly administered to the left and right LI4 points, this time with the subjects observing the procedure. In all conditions the subjects gave their judgement as Yes or No in response to questions asking them to identify the needle type. The proportion of correct judgements (P(C)) was computed for the last part of the trial in left and right LI4 points, and the rates of correctly identified needles for each trial were obtained. The subjects' accuracy of discrimination between the real and sham acupuncture needles in left and right LI4 points was not significantly different from that based on pure guess (P(C)=0.50 (chance level)), which indicates complete inability to discriminate between needles. The rates of correctly identified needles using touch, vision and a combination of both senses were not significantly different (p=0.807). The findings from this study show that this sham acupuncture device successfully blinded subjects to real and sham press needles, suggesting that it is effective for subject blinding in studies on acupuncture using press needles, and facilitating evaluation of the effects of acupuncture in placebo-controlled trials using a rigorous scientific research methodology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
2013-01-04
plane electrode setup. The discharge cell had a point- to-plate geometry with the high-voltage electrode being either stain-less steel needle with...influence of the electrode properties were investigated using 2 different electrodes : a stainless steel needle with a 20μm radius of curvature tip, and an...breakdown phenomena developing around a needle -like high voltage electrode , with a typical radius of curvature r0 ~ 0.01- 0.1mm. The volumetric force
Alsaeed, A; Thallaj, A; Alzahrani, T; Khalil, N; Aljazaeri, A
2014-10-01
The most common peripheral nerve blocks used in umbilical hernia repair are rectus sheath block and regional block (caudal block). Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this study is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery, and to evaluate the easiness of soft tissue puncture and ultrasonic appearance of two different needle types. Twenty two (22) pediatric patients (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz linear probe. An ultrasound-guided rectus sheath block in the lateral edge of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). A 22 gauge short beveled sharp cutting needle 1.1 x 30 mm needle A (BD Insyte--W, Vialon material. Spain) was used in one side, and a Stimuplex A insulated Needle 22G 50mm (needle B) was used on the other side. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia were evaluated. Ultrasonograghic visualization of the posterior sheath was possible in all patients. Needle A scored 72.7% of excellent needle tip and shaft view (16 out of 22) compared to 63.63% for needle B (14 out of 22). None of the needles scored poor view. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one child who postoperatively requested morphine 0.1 mg/kg intravenously in recovery room. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia in the lateral edge of the rectus muscle. Use of the sharp short beveled needle of 22 gauge intravenous (IV) cannula stylet provides easy, less traumatic skin and rectus muscle penetration and better needle visualization by the ultrasound.
NASA Astrophysics Data System (ADS)
Matthews, Benjamin D.; LaVan, David A.; Overby, Darryl R.; Karavitis, John; Ingber, Donald E.
2004-10-01
We describe the design and fabrication of a temperature-controlled electromagnetic microneedle (EMN) to generate custom magnetic field gradients for biomedical and biophysical applications. An electropolishing technique was developed to sharpen the EMN pole tip to any desired radius between 100 nm and 20 μm. The EMN can be used to apply strong static or dynamic forces (>50nN) to micrometer- or nanometer-sized magnetic beads without producing significant heating or needle movement. Large tip radii (20 μm) allow magnetic force application to multiple magnetic beads over a large area, while small radii (0.1-6 μm) can be used to selectively pull or capture single magnetic beads from within a large population of similar particles. The customizable EMN is thus well suited for micro- and nanomanipulation of magnetic particles linked to biomolecules or living cells.
Postdural puncture headache: comparison of 25-gauge Whitacre and Quincke needles.
Buettner, J; Wresch, K P; Klose, R
1993-01-01
To evaluate the influence of the shape of the needle tip on postdural puncture headache (PDPH) independent of the needle diameter, a 25-gauge Whitacre and a 25-gauge Quincke needle were compared. In a prospective, randomized, double-blind fashion, the study was carried out on 400 patients who received spinal anesthesia for operations of the lower extremities. The 25-gauge Whitacre needle (group 1) and the 25-gauge Quincke needle (group 2) were randomly assigned to the patients, 200 in each group. Patients were interviewed postoperatively on days 1, 3, 5, and 7 using a standardized questionnaire. Only postural headache was defined as PDPH. The intensity of both postural and nonpostural headache were quantified using a 4-point rating scale and a visual analog pain scale (VAS). Statistical analysis was performed with parametric and nonparametric tests when appropriate, p < or = 0.05 was considered as significant. There were no differences in age and sex distribution between the two groups. Significantly more patients in group 2 (8.5%) complained of PDPH than in group 1 (3%, p < or = 0.02). Duration of PDPH ranged from 1-3 days (median: 1) in group 1, and from 1-9 days (median: 3) in group 2. This difference closely approached significance (p = 0.058). The mean maximal intensity of PDPH was comparable in both groups. Severe PDPH occurred only in two patients of group 2. One of them required a blood patch. With respect to the nonpostural headache, no significant differences were seen. The use of a conical tipped Whitacre needle results in significantly less PDPH compared to a standard Quincke spinal needle of the same size.
Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.
Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John
2018-01-01
In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.
Influence of needle position on lumbar segmental nerve root block selectivity.
Wolff, André P; Groen, Gerbrand J; Wilder-Smith, Oliver H
2006-01-01
In patients with chronic low back pain radiating to the leg, segmental nerve root blocks (SNRBs) are performed to predict surgical outcome and identify the putative symptomatic spinal nerve. Epidural spread may lead to false interpretation, affecting clinical decision making. Systematic fluoroscopic analysis of epidural local anesthetic spread and its relationship to needle tip location has not been published to date. Study aims include assessment of epidural local anesthetic spread and its relationship to needle position during fluoroscopy-assisted blocks. Patients scheduled for L4, L5, and S1 blocks were included in this prospective observational study. Under fluoroscopy and electrostimulation, they received 0.5 mL of a mixture containing lidocaine 5 mg and iohexol 75 mg. X-rays with needle tip and contrast were scored for no epidural spread (grade 0), local spread epidurally (grade 1), or to adjacent nerve roots (grade 2). Sixty-five patients were analyzed for epidural spread, 62 for needle position. Grade 1 epidural spread occurred in 47% of L4 and 28% of L5 blocks and grade 2 spread in 3 blocks (5%; L5 n = 1, S1 n = 2). For lumbar blocks, the needle was most frequently found in the lateral upper half of the intervertebral foramen. Epidural spread occurred more frequently with medial needle positions (P = .06). The findings suggest (P = .06) that the risk of grade 1 and 2 lumbar epidural spread, which results in decreased SNRB selectivity, is greater with medial needle positions in the intervertebral foramen. The variability in anatomic position of the dorsal root ganglion necessitates electrostimulation to guide SNRB in addition to fluoroscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, S; Kim, R; Benhabib, S
Purpose: HDR brachytherapy using interstitial needle template for cervical cancer is commonly delivered in 4-5 fractions. Routine verification of needle positions before each fraction is often based on radiographic imaging of implanted fiducial markers. The current study evaluated interfractional displacement of implanted fiducial markers using CT images. Methods: 9 sequential patients with cervical interstitial needle implants were evaluated. The superior and inferior borders of the target volumes were defined by fiducial markers in planning CT. The implant position was verified with kV orthogonal images before each fraction. A second CT was acquired prior 3rd fraction (one or 2 days postmore » planning CT). Distances from inferior and superior fiducial markers to pubic symphysis plane (perpendicular to vaginal obtulator)were measured. Distance from needle tip of a reference needle (next to the inferior marker) to the pubic symphysis plane was also determined. The difference in fiducial marker distance or needle tip distance between planning CT and CT prior 3rd fraction were measured to assess markers migration and needle displacement. Results: The mean inferior marker displacement was 4.5 mm and ranged 0.9 to 11.3 mm. The mean superior marker displacement was 2.7 mm and ranged 0 to 10.4 mm. There was a good association between inferior and superior marker displacement (r=0.95). Mean averaged inferior and superior marker displacement was 3.3 mm and ranged from 0.1 to 10.9 mm, with a standard deviation of 3.2 mm. The mean needle displacement was 5.6 mm and ranged 0.2 to 15.6 mm. Needle displacements were reduced (p<0.05) after adjusting according to needle-to-fiducials distance. Conclusion: There were small fiducial marker displacements between HDR fractions. Our study suggests a target margin of 9.7 mm to cover interfractional marker displacements (in 95% cases) for pretreatment verification based on radiographic imaging.« less
Fluoroscopy-Guided Sacroiliac Joint Injection: Description of a Modified Technique.
Kasliwal, Prasad Jaychand; Kasliwal, Sapana
2016-02-01
Sacroiliac joint (SIJ) pathology is a common etiologic cause for 10 - 27% of cases of mechanical low back pain (LBP) below the L5 level. In the absence of definite clinical or radiologic diagnostic criteria, controlled blocks of the SIJ have become the choice assessment method for making the diagnosis of SIJ pain. The SI joint is most often characterized as a large, auricular-shaped, diarthrodial synovial joint. In reality, its synovial characteristic is limited only to the distal third and anterior third. In SIJ interventions, the lateral view has been underutilized. In our technique, we used the lateral view to create a three-dimensional view of the SIJ to aid in gauging the accurateness of the contrast spread and to obtain a precise block. After obtaining appropriate fluoroscopic images, a curved tip spinal needle was directed into the inferior aspect of the SIJ using a posterior approach. As the needle contacts firm tissues on the posterior aspect of the joint, position of the needle tip is checked using lateral fluoroscopy. In the lateral view, the needle tip position is manipulated to keep it in the anterior third of the SIJ and contrast is injected. Our criteria for accurate SIJ block, in posteroanterior (PA) view, is the injection of the contrast medium should outline the joint space and the contrast medium should be seen to travel cephalad along the joint line. In the lateral view, the contrast medium most densely outlines the parameter of the joint. We have utilized this method with good effect in approximately 30 cases over one year. Out of 30 cases, needle position and contrast spread was satisfactory in 28 and 27 cases, respectively. So satisfactory needle placement and contrast spread was in 93% and 87% cases. Pain relief of 80% or more after intra-articular injection of local anesthetic was seen in 50% (15 of 30) patients; pain relief of 50 - 79% was witnessed in 30% (9 of 30) patients. Thus, pain decreased 50% or more in 80% (24 of 30) of the joints. Out of 24 joints where we got satisfactory needle position and contrast spread, 23 joints got more than 50% relief. Thus, if needle position and contrast spread is satisfactory as per the criteria, pain relief of 50% or more was in 96% (23 of 24) of joints. There are few possible limitations with this study like difficulty to go up to the anterior third of the SIJ, it may be more painful as a narrow joint line has to be travelled in depth, sciatic numbness due to drug leak, or injuring the pelvic structure. Advantages of this method are that depth and level of the needle tip for a SIJ block is described for the more precise block. This will reduce false positive and false negative results, i.e., sensitivity and specificity of SIJ blocks and results for diagnostic blocks become more reliable. It will also reduce the chances of a case getting abandoned due to inappropriate contrast spread obscuring the fluoroscopic landmarks. As we know the depth of the needle, the chances of injuring pelvic structures become less and safety improves.
Lee, S H; Lee, N Y
2013-06-01
Pain control, which is necessary during most dental procedures, is administered by injecting a local anaesthetic. Because the injection itself can be painful, the procedure via which pain is reduced warrants continued investigation. Only a few studies regarding the reaction of children to dental needle insertion without the use of topical anaesthetics have been reported. This study was conducted to evaluate the efficacy of the local anaesthetic procedure without topical application as compared to the conventional insertion technique for alleviating pain in children receiving local anaesthesia injections. For the alternative injection procedure, the dentist quickly and gently pulled or pushed the clean and dried loose tissue at the injection site over the tip of the needle to a depth of 1 to 1.5 mm. When the end of the bevel of the needle tip entered the tissue, a few drops of solution were released, after which the needle was advanced to its proper and intended depth to continue anaesthetic release. There was a significant difference regarding the pain response between the alternative insertion technique (less painful) and the conventional one according to Sound, Eye, and Motor (SEM) scale ratings (P < 0.000). No significant difference was observed in the response between the maxilla and mandible, nor between boys and girls, between the conventional and alternative techniques. This alternative technique can reduce discomfort in paediatric dental patients and allow the clinician to administer a superficial local anaesthesia injection before the needle is advanced into deeper tissue. This technique is simple, quick, devoid of additional costs, and potentially more effective than the conventional needle insertion method.
Naganobu, Kiyokazu; Hagio, Mitsuyoshi
2007-01-01
To assess the accuracy of the 'hanging drop method' for identifying the extradural space in anaesthetized dogs positioned in sternal or lateral recumbency. Prospective randomized-experimental study. Seventeen clinically healthy adult dogs, 10 females and seven males weighing 8.4-26.2 kg. Dogs were positioned in either sternal (n = 8) or lateral (n = 9) recumbency under general anaesthesia. A 20 SWG spinal needle pre-filled with 0.9% saline was advanced through the skin into the lumbosacral extradural space and the response of the saline drop recorded, i.e. whether it: 1) was aspirated from the hub into the needle; 2) remained within the hub, or 3) moved synchronously with i) spontaneous respiration, ii) heart beat or iii) manual lung inflation. The position of the needle tip was ultimately determined by positive contrast radiography. One dog positioned in lateral recumbency was excluded from the study because bleeding occurred from the needle hub. Saline was aspirated into the needle in seven of eight dogs held in sternal recumbency but in none of the dogs positioned in lateral recumbency. Accurate needle tip placement in the extradural space was confirmed by positive contrast radiography in all dogs. The 'hanging drop' method, when performed with a spinal needle, appears to be a useful technique for identifying the location of the extradural space in anaesthetized medium-sized dogs positioned in sternal, but not in lateral recumbency. The technique may yield 'false negative' results when performed in dogs positioned in sternal recumbency.
Ishizaka, H; Shiraishi, A; Awata, S; Shimizu, A; Hirasawa, S
2011-01-01
Thermal tumour ablation techniques such as radiofrequency (RF) ablation are applied for radical removal of local tumours as an easier, less invasive alternative to surgical resection. A serious drawback of thermal ablation, however, is that the ablation area cannot be accurately assessed during the procedure. To achieve real-time feedback and exact and safe ablation, a superfine thermocouple-needle system (TNS) comprising a 0.25-mm diameter thermocouple embedded in a 22-G, 15-cm-long needle was devised and efficacy was tested in vitro using porcine livers (n = 15) and in vivo using rabbit back muscles (n = 2) and livers (n = 3). A 17-gauge RF electrode with a 2 cm active tip was used for ablation. The TNS was inserted 1 cm from the active tip of the RF electrode and liver temperature around the electrode was measured concurrently. The RF current was cut off when the temperature reached 60°C or after 5 min at ≥50°C. Porcine livers and rabbit back muscles were then cut along a plane passing through the axes of the electrode and the TNS. In rabbit livers, contrast-enhanced CT was performed to evaluate ablation areas. Ablation areas in cut surfaces of porcine livers exhibited well-defined discoloured regions and the TNS tip precisely pinpointed the margin of the ablation area. Contrast-enhanced CT of rabbit livers showed the TNS tip accurately located at the margin of areas without contrast enhancement. These results indicate that the TNS can accurately show ablation margins and that placing the TNS tip at the intended ablation margin permits exact thermal ablation. PMID:21937618
Ishizaka, H; Shiraishi, A; Awata, S; Shimizu, A; Hirasawa, S
2011-12-01
Thermal tumour ablation techniques such as radiofrequency (RF) ablation are applied for radical removal of local tumours as an easier, less invasive alternative to surgical resection. A serious drawback of thermal ablation, however, is that the ablation area cannot be accurately assessed during the procedure. To achieve real-time feedback and exact and safe ablation, a superfine thermocouple-needle system (TNS) comprising a 0.25-mm diameter thermocouple embedded in a 22-G, 15-cm-long needle was devised and efficacy was tested in vitro using porcine livers (n = 15) and in vivo using rabbit back muscles (n = 2) and livers (n = 3). A 17-gauge RF electrode with a 2 cm active tip was used for ablation. The TNS was inserted 1 cm from the active tip of the RF electrode and liver temperature around the electrode was measured concurrently. The RF current was cut off when the temperature reached 60°C or after 5 min at ≥50°C. Porcine livers and rabbit back muscles were then cut along a plane passing through the axes of the electrode and the TNS. In rabbit livers, contrast-enhanced CT was performed to evaluate ablation areas. Ablation areas in cut surfaces of porcine livers exhibited well-defined discoloured regions and the TNS tip precisely pinpointed the margin of the ablation area. Contrast-enhanced CT of rabbit livers showed the TNS tip accurately located at the margin of areas without contrast enhancement. These results indicate that the TNS can accurately show ablation margins and that placing the TNS tip at the intended ablation margin permits exact thermal ablation.
Adam, Philip R; Dickenson, Nicholas E; Greenwood, Jamie C; Picking, Wendy L; Picking, William D
2014-11-01
Shigella flexneri causes bacillary dysentery, an important cause of mortality among children in the developing world. Shigella secretes effector proteins via its type III secretion system (T3SS) to promote bacterial uptake into human colonic epithelial cells. The T3SS basal body spans the bacterial cell envelope anchoring a surface-exposed needle. A pentamer of invasion plasmid antigen D lies at the nascent needle tip and invasion plasmid antigen B (IpaB) is recruited into the needle tip complex on exposure to bile salts. From here, IpaB forms a translocon pore in the host cell membrane. Although the mechanism by which IpaB inserts into the membrane is unknown, it was recently shown that recombinant IpaB can exist as either a monomer or tetramer. Both of these forms of IpaB associate with membranes, however, only the tetramer forms pores in liposomes. To reveal differences between these membrane-binding events, Cys mutations were introduced throughout IpaB, allowing site-specific fluorescence labeling. Fluorescence quenching was used to determine the influence of oligomerization and/or membrane association on the accessibility of different IpaB regions to small solutes. The data show that the hydrophobic region of tetrameric IpaB is more accessible to solvent relative to the monomer. The hydrophobic region appears to promote membrane interaction for both forms of IpaB, however, more of the hydrophobic region is protected from solvent for the tetramer after membrane association. Limited proteolysis demonstrated that changes in IpaB's oligomeric state may determine the manner by which it associates with phospholipid membranes and the subsequent outcome of this association. © 2014 Wiley Periodicals, Inc.
Adam, Philip R.; Dickenson, Nicholas E.; Greenwood, Jamie C.; Picking, Wendy L.; Picking, William D.
2014-01-01
Shigella flexneri causes bacillary dysentery, an important cause of mortality among children in the developing world. Shigella secretes effector proteins via its type III secretion system (T3SS) to promote bacterial uptake into human colonic epithelial cells. The T3SS basal body spans the bacterial cell envelope anchoring a surface-exposed needle. A pentamer of invasion plasmid antigen D (IpaD) lies at the nascent needle tip and IpaB is recruited into the needle tip complex upon exposure to bile salts. From here, IpaB forms a translocon pore in the host cell membrane. Although the mechanism by which IpaB inserts into the membrane is unknown, it was recently shown that recombinant IpaB can exist as either a monomer or tetramer. Both of these forms of IpaB associate with membranes, however, only the tetramer forms pores in liposomes. To reveal differences between these membrane-binding events, Cys mutations were introduced throughout IpaB, allowing site-specific fluorescence labeling. Fluorescence quenching was used to determine the influence of oligomerization and/or membrane association on the accessibility of different IpaB regions to small solutes. The data show that the hydrophobic region of tetrameric IpaB is more accessible to solvent relative to the monomer. The hydrophobic region appears to promote membrane interaction for both forms of IpaB, however, more of the hydrophobic region is protected from solvent for the tetramer after membrane association. Limited proteolysis demonstrated that changes in IpaB’s oligomeric state may determine the manner by which it associates with phospholipid membranes and the subsequent outcome of this association. PMID:25103195
Characterisation of a fibre optic Raman probe within a hypodermic needle.
Iping Petterson, Ingeborg E; Day, John C C; Fullwood, Leanne M; Gardner, Benjamin; Stone, Nick
2015-11-01
We demonstrate the first use of a multifibre Raman probe that fits inside the bore of a hypodermic needle. A Raman probe containing multiple collection fibres provides improved signal collection efficiency in biological samples compared with a previous two-fibre design. Furthermore, probe performance (signal-to-noise ratios) compared favourably with the performance achieved in previous Raman microscope experiments able to distinguish between benign lymph nodes, primary malignancies in lymph nodes and secondary malignancies in lymph nodes. The experimental measurements presented here give an indication of the sampling volume of the Raman needle probe in lymphoid tissues. Liquid tissue phantoms were used that contained scattering medium encompassing a range of scattering properties similar to those of a variety of tissue types, including lymph node tissues. To validate the appropriateness of the phantoms, the sampling depth of the probe was also measured in excised lymph node tissue. More than 50 % of Raman photons collected were found to originate from between the tip of the needle and a depth of 500 μm into the tissue. The needle probe presented here achieves spectral quality comparable to that in numerous studies previously demonstrating Raman disease discrimination. It is expected that this approach could achieve targeted subcutaneous tissue measurements and be viable for use for the in vivo Raman diagnostics of solid organs located within a few centimetres below the skin's surface. Graphical Abstract Schematic of multi-fibre Raman needle probe with disposible tips and proximal optical filtration.
Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.
Cockburn, John F; Khosh, Stefan K
2014-04-01
This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.
NASA Astrophysics Data System (ADS)
Motogi, Jun; Sugiyama, Yukiya; Laakso, Ilkka; Hirata, Akimasa; Inui, Koji; Tamura, Manabu; Muragaki, Yoshihiro
2016-06-01
The in situ electric field in the peripheral nerve of the skin is investigated to discuss the selective stimulation of nerve fibres. Coaxial planar electrodes with and without intra-epidermal needle tip were considered as electrodes of a stimulator. From electromagnetic analysis, the tip depth of the intra-epidermal electrode should be larger than the thickness of the stratum corneum, the electrical conductivity of which is much lower than the remaining tissue. The effect of different radii of the outer ring electrode on the in situ electric field is marginal. The minimum threshold in situ electric field (rheobase) for free nerve endings is estimated to be 6.3 kV m-1. The possible volume for electrostimulation, which can be obtained from the in situ electric field distribution, becomes deeper and narrower with increasing needle depth, suggesting that possible stimulation sites may be controlled by changing the needle depth. The injection current amplitude should be adjusted when changing the needle depth because the peak field strength also changes. This study shows that intra-epidermal electrical stimulation can achieve stimulation of small fibres selectively, because Aβ-, Aδ-, and C-fibre terminals are located at different depths in the skin.
NASA Astrophysics Data System (ADS)
Ng, H. B.; Shearwood, C.
2007-12-01
The successful development of micro-needles can help transport drugs and vaccines both effectively and painlessly across the skin. However, not all micro-needles are strong enough to withstand the insertion forces and viscoelasticity of the skin. The work here focuses on the micro-fabrication of high aspect ratio needles with careful control of needle-profile using dry etching technologies. Silicon micro-needles, 150μm in length with base-diameters ranging from 90 to 240μm have been investigated in this study. A novel, multiple-sacrificial approach has been demonstrated as suited to the fabrication of long micro-needle bodies with positive profiles. The parameters that control the isotropic etching are adjusted to control the ratio of the needle-base diameter to needle length. By careful control of geometry, the needle profile can be engineered to give a suitable tip size for penetration, as well as a broad needle base to facilitate the creation of either single or multiple-through holes. This approach allows the mechanical properties of the otherwise brittle needles to be optimized. Finite element analysis indicates that the micro-needles will fracture prematurely due to buckling, with forces ranging from 10 to 30mN.
Mignon, Paul; Poignet, Philippe; Troccaz, Jocelyne
2018-05-29
Robotic control of needle bending aims at increasing the precision of percutaneous procedures. Ultrasound feedback is preferable for its clinical ease of use, cost and compactness but raises needle detection issues. In this paper, we propose a complete system dedicated to robotized guidance of a flexible needle under 3D ultrasound imaging. This system includes a medical robot dedicated to transperineal needle positioning and insertion, a rapid path planning for needle steering using bevel-tip needle natural curvature in tissue, and an ultrasound-based automatic needle detection algorithm. Since ultrasound-based automatic needle steering is often made difficult by the needle localization in biological tissue, we quantify the benefit of using flexible echogenic needles for robotized guidance under 3D ultrasound. The "echogenic" term refers to the etching of microstructures on the needle shaft. We prove that these structures improve needle visibility and detection robustness in ultrasound images. We finally present promising results when reaching targets using needle steering. The experiments were conducted with various needles in different media (synthetic phantoms and ex vivo biological tissue). For instance, with nitinol needles the mean accuracy is 1.2 mm (respectively 3.8 mm) in phantoms (resp. biological tissue).
McShan, Andrew C; Kaur, Kawaljit; Chatterjee, Srirupa; Knight, Kevin M; De Guzman, Roberto N
2016-08-01
The type III secretion system (T3SS) is essential for the pathogenesis of many bacteria including Salmonella and Shigella, which together are responsible for millions of deaths worldwide each year. The structural component of the T3SS consists of the needle apparatus, which is assembled in part by the protein-protein interaction between the tip and the translocon. The atomic detail of the interaction between the tip and the translocon proteins is currently unknown. Here, we used NMR methods to identify that the N-terminal domain of the Salmonella SipB translocon protein interacts with the SipD tip protein at a surface at the distal region of the tip formed by the mixed α/β domain and a portion of its coiled-coil domain. Likewise, the Shigella IpaB translocon protein and the IpaD tip protein interact with each other using similar surfaces identified for the Salmonella homologs. Furthermore, removal of the extreme N-terminal residues of the translocon protein, previously thought to be important for the interaction, had little change on the binding surface. Finally, mutations at the binding surface of SipD reduced invasion of Salmonella into human intestinal epithelial cells. Together, these results reveal the binding surfaces involved in the tip-translocon protein-protein interaction and advance our understanding of the assembly of the T3SS needle apparatus. Proteins 2016; 84:1097-1107. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Liang, Huei-Lung; Li, Ming-Feng; Chiang, Chia-Ling; Chen, Matt Chiung-Yu; Wu, Chieh-Jen; Pan, Huay-Ben
2017-06-01
To report the technique and clinical outcome of subintimal re-entry in chronic iliac artery occlusion by using a Colapinto transjugular intrahepatic portosystemic shunt (TIPS) needle under rotational angiography (cone-beam computed tomography; CT) imaging guidance. Patients with chronic iliac artery occlusion with earlier failed attempts at conventional percutaneous recanalization during the past 5 years were enrolled in our study. In these patients, an ipsilateral femoral access route was routinely utilized in a retrograde fashion. A Colapinto TIPS Needle was used to aid the true lumen re-entry after failed conventional intraluminal or subintimal guidewire and catheter-based techniques. The puncture was directed under rotational angiography cone-beam CT guidance to re-enter the abdominal aorta. Bare metallic stents 8-10 mm in diameter were deployed in the common iliac artery, and followed by balloon dilation. Ten patients (9 male; median age, 75 years) were included in our investigation. The average occlusion length was 10.2 cm (range, 4-15 cm). According to the Trans-Atlantic Inter-Society Consensus (TASC) II classification, there were five patients each with Class B and D lesions. Successful re-entry was achieved in all patients without procedure-related complications. The ankle-brachial index (ABI) values increased from 0.38-0.79 to 0.75-1.28 after the procedure. Imaging follow-up (> 6 months) was available in six patients with patency of all stented iliac artery. Thereafter, no complaints of recurrent clinical symptoms occurred during the follow-up period. The use of Colapinto TIPS needle, especially under cone-beam CT image guidance, appears to be safe and effective to re-enter the true lumen in a subintimal angioplasty for a difficult chronic total iliac occlusion. Copyright © 2017. Published by Elsevier Taiwan LLC.
Design for gas chromatography-corona discharge-ion mobility spectrometry.
Jafari, Mohammad T; Saraji, Mohammad; Sherafatmand, Hossein
2012-11-20
A corona discharge ionization-ion mobility spectrometry (CD-IMS) with a novel sample inlet system was designed and constructed as a detector for capillary gas chromatography. In this design, a hollow needle was used instead of a solid needle which is commonly used for corona discharge creation, helping us to have direct axial interfacing for GC-IMS. The capillary column was passed through the needle, resulting in a reaction of effluents with reactant ions on the upstream side of the corona discharge ionization source. Using this sample introduction design, higher ionization efficiency was achieved relative to the entrance direction through the side of the drift tube. In addition, the volume of the ionization region was reduced to minimize the resistance time of compounds in the ionization source, increasing chromatographic resolution of the instrument. The effects of various parameters such as drift gas flow, makeup gas flow, and column tip position inside the needle were investigated. The designed instrument was exhaustively validated in terms of sensitivity, resolution, and reproducibility by analyzing the standard solutions of methyl isobutyl ketone, heptanone, nonanone, and acetophenone as the test compounds. The results obtained by CD-IMS detector were compared with those of the flame ionization detector, which revealed the capability of the proposed GC-IMS for two-dimensional separation (based on the retention time and drift time information) and identification of an analyte in complex matrixes.
Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier
2017-04-01
The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Noncontact viscoelastic measurement of polymer thin films in a liquid medium using a long-needle AFM
NASA Astrophysics Data System (ADS)
Guan, Dongshi; Barraud, Chloe; Charlaix, Elisabeth; Tong, Penger
We report noncontact measurement of the viscoelastic property of polymer thin films in a liquid medium using frequency-modulation atomic force microscopy (FM-AFM) with a newly developed long-needle probe. The probe contains a long vertical glass fiber with one end adhered to a cantilever beam and the other end with a sharp tip placed near the liquid-film interface. The nanoscale flow generated by the resonant oscillation of the needle tip provides a precise hydrodynamic force acting on the soft surface of the thin film. By accurately measuring the mechanical response of the thin film, we obtain the elastic and loss moduli of the thin film using the linear response theory of elasto-hydrodynamics. The experiment verifies the theory and demonstrates its applications. The technique can be used to accurately measure the viscoelastic property of soft surfaces, such as those made of polymers, nano-bubbles, live cells and tissues. This work was supported by the Research Grants Council of Hong Kong SAR.
Alderliesten, Tanja; Loo, Claudette; Paape, Anita; Muller, Sara; Rutgers, Emiel; Peeters, Marie-Jeanne Vrancken; Gilhuijs, Kenneth
2010-06-01
The aim of this study was to investigate the feasibility of image-guided navigation approaches to demarcate breast cancer on the basis of preacquired magnetic resonance (MR) imaging in supine patient orientation. Strategies were examined to minimize the uncertainty in the instrument-tip position, based on the hypothesis that the release of instrument pressure returns the breast tissue to its predeformed state. For this purpose, four sources of uncertainty were taken into account: (1) U(ligaments): Uncertainty in the reproducibility of the internal mammary gland geometry during repeat patient setup in supine orientation; (2) U(r_breathing): Residual uncertainty in registration of the breast after compensation for breathing motion using an external marker; (3) U(reconstruction): Uncertainty in the reconstructed location of the tip of the needle using an optical image-navigation system (phantom experiments, n = 50); and (4) U(deformation): Uncertainty in displacement of breast tumors due to needle-induced tissue deformations (patients, n = 21). A Monte Carlo study was performed to establish the 95% confidence interval (CI) of the combined uncertainties. This region of uncertainty was subsequently visualized around the reconstructed needle tip as an additional navigational aid in the preacquired MR images. Validation of the system was performed in five healthy volunteers (localization of skin markers only) and in two patients. In the patients, the navigation system was used to monitor ultrasound-guided radioactive seed localization of breast cancer. Nearest distances between the needle tip and the tumor boundary in the ultrasound images were compared to those in the concurrently reconstructed MR images. Both U(reconstruction) and U(deformation) were normally distributed with 0.1 +/- 1.2 mm (mean +/- 1 SD) and 0.1 +/- 0.8 mm, respectively. Taking prior estimates for U(ligaments) (0.0 +/- 1.5 mm) and U(r_breathing) (-0.1 +/- 0.6 mm) into account, the combined impact resulted in 3.9 mm uncertainty in the position of the needle tip (95% CI) after release of pressure. The volunteer study showed a targeting accuracy comparable to that in the phantom experiments: 2.9 +/- 1.3 versus 2.7 +/- 1.1 mm, respectively. In the patient feasibility study, the deviations were within the 3.9 mm CI. Image-guided navigation to demarcate breast cancer on the basis of preacquired MR images in supine orientation appears feasible if patient breathing is tracked during the navigation procedure, positional uncertainty is visualized and pressure on the localization instrument is released prior to verification of its position.
Mechanics of anesthetic needle penetration into human sciatic nerve.
Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A
2018-06-06
Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.
Takazawa, Shinya; Ishimaru, Tetsuya; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-11-01
We have developed a thin needle driver with multiple degrees-of-freedom (DOFs) for neonatal laparoscopic surgery. The tip of this needle driver has three DOFs for grasp, deflection and rotation. Our aim was to evaluate the performance of the multi-DOF needle driver in vertical plane suturing. Six pediatric surgeons performed four directional suturing tasks in the vertical plane using the multi-DOF needle driver and a conventional one. Assessed parameters were the accuracy of insertion and exit, the depth of suture, the inclination angle of the needle and the force applied on the model. In left and right direction sutures, the inclination angle of the needle with the multi-DOF needle driver was significantly smaller than that with the conventional one (p = 0.014, 0.042, respectively). In left and right direction sutures, the force for pulling the model with the multi-DOF needle driver was smaller than that with the conventional one (p = 0.036, 0.010, respectively). This study showed that multi-directional suturing on a vertical plane using the multi-DOF needle driver had better needle trajectories and was less invasive as compared to a conventional needle driver.
1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections
Marker, David R.; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.; Carrino, John A.; Fritz, Jan
2017-01-01
PURPOSE The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. METHODS A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. RESULTS Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. CONCLUSION 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus. PMID:28420598
1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.
Marker, David R; U Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A; Fritz, Jan
2017-01-01
The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1-5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus.
Guan, Xiaoming; Ma, Yingchun; Gisseman, Jordan; Kleithermes, Christopher; Liu, Juan
2017-01-01
To demonstrate the tips and tricks of a simpler technique for single-site sacrocolpopexy using barbed suture anchoring and retroperitoneal tunneling to make the procedure more efficient and reproducible. Step-by-step description of surgical tutorial using a narrated video (Canadian Task Force classification III). Academic tertiary care hospital. Patient with Stage III uterine prolapse. Sacrocolpopexy is increasing utilized since the FDA warning about complications of vaginal mesh surgery. It is the gold standard for repair of apical prolapse. However, there is great variation in the sacrocolpopexy procedure techniques and they have not been standardized. Traditional single-site laparoscopic sacrocolpopexy is very challenging as the procedure time is long and suturing is difficult. The advantages of suturing with wristed needle drivers in robotic single-site surgery simplify this complex procedure. Furthermore, using barbed suture anchoring and peritoneal tunneling technique potentially decreases the surgeon's learning curve and makes the procedure reproducible. In this video, we demonstrate a supracervial hysterectomy with a stepwise explanation of the correct technique for performing a robotic single incision sacrocolpopexy. Sacrocolpopexy is increasing used since the US Food and Drug Administration warning about complications of vaginal mesh surgery. It is the gold standard for repair of apical prolapse. However, a great variation exists in the sacrocolpopexy procedure techniques that need to be standardized. Traditional single-site laparoscopic sacrocolpopexy is very challenging because the procedure time is long and suturing is difficult. The advantages of suturing with wristed needle drivers in robotic single-site surgery simplify this complex procedure. Furthermore, using the barbed suture anchoring and peritoneal tunneling technique potentially decreases the surgeon's learning curve and makes the procedure reproducible. In this video, we demonstrate a supracervical hysterectomy with a stepwise explaation of the correct technique for performing a robotic single-incision sacrocolpopexy. The possibility of using the barbed suture and peritoneal tunneling technique with wristed needle drivers in robotic single-site sacrocolpopexy offers the possibility of an effective, safe, reproducible, and cosmetic surgical option. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Fujishiro, Mitsuhiro; Sugita, Noriyuki
2013-01-01
The high frequency of complications accompanying endoscopic submucosal dissection (ESD) and its complex processes suggest that the process requires improvement. The objective of the present study was to investigate the feasibility of an innovated splash-needle for ESD. An animal feasibility study with a living pig was conducted. Six resections per portion (esophagus and upper, middle, and lower thirds of the stomach) in a total of 24 resections were carried out by using an original splash-needle or an innovated splash-needle. Major innovations were a thicker part in the middle of the knife and a metal plate on the tip of the sheath to obtain more coagulation ability. Injection solution in the submucosal layer was also changed due to possible influence on the outcomes. Main outcome measurements were entire procedure time, cutting speed, and frequency of bleeding during ESD. All the 24 resections were completed without complications. Among the obtained data, only mean cutting speeds were significantly influenced by location of the simulated lesion, which revealed that ESD at the upper third was significantly quicker than that at the lower third (P = 0.01), and ESD at the esophagus was significantly slower than that at the three parts of the stomach (P < 0.01). There was no significant difference between the different knives in each variable. The innovated splash-needle will be feasible for human use, although the safety and advantages in clinical settings must be elucidated by proper comparative studies with existing knives in humans. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.
Endo, Toshiaki; Nagasawa, Kunihiko; Umemura, Kota; Baba, Tsuyoshi; Henmi, Hirofumi; Saito, Tsuyoshi
2011-01-01
Single-incision laparoscopic surgery (SILS) has been quickly accepted, especially for women, because the cosmetic benefits may be greater than with ordinary laparoscopic surgery. In gynecologic disease, SILS is appropriate for diagnostic laparoscopy, oophorectomy, and salpingectomy, among other conditions. In addition, the knot-tying process for intracorporeal suturing during SILS is a major rate-limiting step and a key determinant of the popularity of SILS. Although a roticulator instrument is useful for creating the needed operative angle, knot tying is still believed to be difficult. We have devised a remarkably simple knot-tying technique that can be applied during SILS with a SILS Port with a Roticulator and a straight-type needle driver. We determined that, after transfixing the needle, the long tail of the thread should be grasped at around 90 degrees relative to the long axis of tip of the Roticulator, which is articulated at 80 degrees. This automatically forms an ideal C-loop because of gravitation. The needle attached to the long tail should face the distal side from the tip of Roticulator (from the surgeon's perspective). The apex of the C-loop is then toward the proximal side from the tip of the Roticulator (from the perspective of the surgeon). This thread position is important during the knot-tying process. The upper arm of the C-loop should then be entwined by applying a series of axial spinning movements to the rod of the needle driver. At this time, the jaws of the needle driver should be kept open so the thread does not slip off of the rod. The benefit of this technique is that it does not require any special skills; any surgeon able to perform intracorporeal suturing should also be able to easily tie knots during SILS. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.
Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.
Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M
2015-05-01
Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.
Müller, H; Zierski, J
1988-10-03
Huber-point needles, which are thought to be noncoring, are usually recommended for puncture of implanted drug-delivery devices, such as ports and pumps. Nevertheless, we found occlusion by silicone chips deriving from the silicone inlet septum to be a major technical complication. Electron microscopic investigations demonstrated substantial loss of material from the port membrane after repeated puncture with this type of needle. During an in vitro test, multiple puncture with Huber-type cannulas led to a pressure-dependent leakage of a port after only 150 to 750 insertions of a needle. In addition, the forces necessary for puncture or for withdrawal of the needle were increased with Huber-point needles, possibly due to a coring effect. Another disadvantage of the available port needles is the formation of a hook at the tip, which may lead to additional lesion of the port or pump membrane. In our opinion, resterilization of Huber needles, recommended by the manufactures, is not advisable, because it is well known that safe sterilization of small lumina, e.g., the lumen of the needle, is impossible.
A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.
De Falco, Iris; Culmone, Costanza; Menciassi, Arianna; Dankelman, Jenny; van den Dobbelsteen, John J
2018-06-04
Needles are advanced tools commonly used in minimally invasive medical procedures. The accurate manoeuvrability of flexible needles through soft tissues is strongly determined by variations in tissue stiffness, which affects the needle-tissue interaction and thus causes needle deflection. This work presents a variable stiffness mechanism for percutaneous needles capable of compensating for variations in tissue stiffness and undesirable trajectory changes. It is composed of compliant segments and rigid plates alternately connected in series and longitudinally crossed by four cables. The tensioning of the cables allows the omnidirectional steering of the tip and the stiffness tuning of the needle. The mechanism was tested separately under different working conditions, demonstrating a capability to exert up to 3.6 N. Afterwards, the mechanism was integrated into a needle, and the overall device was tested in gelatine phantoms simulating the stiffness of biological tissues. The needle demonstrated the capability to vary deflection (from 11.6 to 4.4 mm) and adapt to the inhomogeneity of the phantoms (from 21 to 80 kPa) depending on the activation of the variable stiffness mechanism. Graphical abstract ᅟ.
Effect of spinal needle characteristics on measurement of spinal canal opening pressure.
Bellamkonda, Venkatesh R; Wright, Thomas C; Lohse, Christine M; Keaveny, Virginia R; Funk, Eric C; Olson, Michael D; Laack, Torrey A
2017-05-01
A wide variety of spinal needles are used in clinical practice. Little is currently known regarding the impact of needle length, gauge, and tip type on the needle's ability to measure spinal canal opening pressure. This study aimed to investigate the relationship between these factors and the opening-pressure measurement or time to obtain an opening pressure. Thirteen distinct spinal needles, chosen to isolate the effects of length, gauge, and needle-point type, were prospectively tested on a lumbar puncture simulator. The key outcomes were the opening-pressure measurement and the time required to obtain that measure. Pressures were recorded at 10-s intervals until 3 consecutive, identical readings were observed. Time to measure opening pressure increased with increasing spinal needle length, increasing gauge, and the Quincke-type (cutting) point (P<0.001 for all). The time to measurement ranged from 30s to 530s, yet all needle types were able to obtain a consistent opening pressure measure. Although opening pressure estimates are unlikely to vary markedly by needle type, the time required to obtain the measurement increased with increasing needle length and gauge and with Quincke-type needles. Copyright © 2017 Elsevier Inc. All rights reserved.
Chen, José Enrique; Nurbakhsh, Babak; Layton, Gillian; Bussmann, Markus; Kishen, Anil
2014-08-01
Complexities in root canal anatomy and surface adherent biofilm structures remain as challenges in endodontic disinfection. The ability of an irrigant to penetrate into the apical region of a canal, along with its interaction with the root canal walls, will aid in endodontic disinfection. The aim of this study was to qualitatively examine the irrigation dynamics of syringe irrigation with different needle tip designs (open-ended and closed-ended), apical negative pressure irrigation with the EndoVac® system, and passive ultrasonic-assisted irrigation, using a computational fluid dynamics model. Syringe-based irrigation with a side-vented needle showed a higher wall shear stress than the open-ended but was localised to a small region of the canal wall. The apical negative pressure mode of irrigation generated the lowest wall shear stress, while the passive-ultrasonic irrigation group showed the highest wall shear stress along with the greatest magnitude of velocity. © 2013 The Authors. Australian Endodontic Journal © 2013 Australian Society of Endodontology.
Frohlich, Michael W
2005-08-01
A new method is presented for twist mounting insect pins onto standard dissecting (teasing) needles. Insect pins, with their sharp points, are ideal for fine dissection of plants, especially of shoot tips and early developing flower buds. Twist mounting makes them convenient and effective dissecting tools to prepare specimens for SEM.
Rapid and precise determination of ATP using a modified photometer
Shultz, David J.; Stephens, Doyle W.
1980-01-01
An inexpensive delay timer was designed to modify a commercially available ATP photometer which allows a disposable tip pipette to be used for injecting either enzyme or sample into the reaction cuvette. The disposable tip pipette is as precise and accurate as a fixed-needle syringe but eliminates the problem of sample contamination and decreases analytical time. (USGS)
Sharp Central Venous Recanalization by Means of a TIPS Needle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honnef, Dagmar, E-mail: honnef@rad.rwth-aachen.de; Wingen, Markus; Guenther, Rolf W.
The purpose of this study was to perform an alternative technique for recanalization of a chronic occlusion of the left brachiocephalic vein that could not be traversed with a guidewire. Restoration of a completely thrombosed left brachiocephalic vein was attempted in a 76-year-old male hemodialysis patient with massive upper inflow obstruction, massive edema of the face, neck, shoulder, and arm, and occlusion of the stented right brachiocephalic vein/superior vena cava. Vessel negotiation with several guidewires and multipurpose catheters proved unsuccessful. The procedure was also non-viable using a long, 21G puncture needle. Puncture of the superior vena cava (SVC) at themore » distal circumference of the stent in the right brachiocephalic vein/superior vena cava, however, was feasible with a transjugular intrahepatic portosystemic shunt (TIPS) set under biplanar fluoroscopy using the distal end of the right brachiocephalic vein as a target, followed by balloon dilatation and partial extraction of thrombotic material of the left brachiocephalic vein with a wire basket. Finally, two overlapping stents were deployed to avoid early re-occlusion. Venography demonstrated complete vessel patency with free contrast media flow via the stents into the SVC, which was reconfirmed in follow-up examinations. Immediate clinical improvement was observed. Venous vascular recanalization of chronic venous occlusion by means of a TIPS needle is feasible as a last resort under certain precautions.« less
NASA Astrophysics Data System (ADS)
Kao, Meng-Chun; Ting, Chien-Kun; Kuo, Wen-Chuan
2018-02-01
Incorrect placement of the needle causes medical complications in the epidural block, such as dural puncture or spinal cord injury. This study proposes a system which combines an optical coherence tomography (OCT) imaging probe with an automatic identification (AI) system to objectively identify the position of the epidural needle tip. The automatic identification system uses three features as image parameters to distinguish the different tissue by three classifiers. Finally, we found that the support vector machine (SVM) classifier has highest accuracy, specificity, and sensitivity, which reached to 95%, 98%, and 92%, respectively.
NASA Astrophysics Data System (ADS)
Spliethoff, Jarich W.; de Boer, Lisanne L.; Meier, Mark A. J.; Prevoo, Warner; de Jong, Jeroen; Kuhlmann, Koert; Bydlon, Torre M.; Sterenborg, Henricus J. C. M.; Hendriks, Benno H. W.; Ruers, Theo J. M.
2016-09-01
There is a strong need to develop clinical instruments that can perform rapid tissue assessment at the tip of smart clinical instruments for a variety of oncological applications. This study presents the first in vivo real-time tissue characterization during 24 liver biopsy procedures using diffuse reflectance (DR) spectroscopy at the tip of a core biopsy needle with integrated optical fibers. DR measurements were performed along each needle path, followed by biopsy of the target lesion using the same needle. Interventional imaging was coregistered with the DR spectra. Pathology results were compared with the DR spectroscopy data at the final measurement position. Bile was the primary discriminator between normal liver tissue and tumor tissue. Relative differences in bile content matched with the tissue diagnosis based on histopathological analysis in all 24 clinical cases. Continuous DR measurements during needle insertion in three patients showed that the method can also be applied for biopsy guidance or tumor recognition during surgery. This study provides an important validation step for DR spectroscopy-based tissue characterization in the liver. Given the feasibility of the outlined approach, it is also conceivable to make integrated fiber-optic tools for other clinical procedures that rely on accurate instrument positioning.
An ultrasound needle insertion guide in a porcine phantom model.
Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I
2013-08-01
We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.
Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes
2011-01-01
To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.
Design of a Teleoperated Needle Steering System for MRI-guided Prostate Interventions
Seifabadi, Reza; Iordachita, Iulian; Fichtinger, Gabor
2013-01-01
Accurate needle placement plays a key role in success of prostate biopsy and brachytherapy. During percutaneous interventions, the prostate gland rotates and deforms which may cause significant target displacement. In these cases straight needle trajectory is not sufficient for precise targeting. Although needle spinning and fast insertion may be helpful, they do not entirely resolve the issue. We propose robot-assisted bevel-tip needle steering under MRI guidance as a potential solution to compensate for the target displacement. MRI is chosen for its superior soft tissue contrast in prostate imaging. Due to the confined workspace of the MRI scanner and the requirement for the clinician to be present inside the MRI room during the procedure, we designed a MRI-compatible 2-DOF haptic device to command the needle steering slave robot which operates inside the scanner. The needle steering slave robot was designed to be integrated with a previously developed pneumatically actuated transperineal robot for MRI-guided prostate needle placement. We describe design challenges and present the conceptual design of the master and slave robots and the associated controller. PMID:24649480
Influence of hearing of 22 G Whitacre and 22 G Quincke needles.
Sundberg, A; Wang, L P; Fog, J
1992-11-01
Audiograms were performed pre-operatively and 2 days postoperatively in 48 patients given spinal anaesthesia for transurethral resection of the prostate. Hearing levels were examined at 1000 Hz and below. Either 22 G standard design (Quincke) needles (n = 25) or 22 G pencil-point design (Whitacre) needles (n = 23) were used. Hearing loss of 10 dB or more at two or more frequencies were observed in six of 25 patients in the Quincke group and in two of 23 patients in the Whitacre group. The mean hearing level was more reduced in the Quincke group. The shape of the tip of the spinal needle seems to be of some importance to the effects on hearing level that may occur after spinal anaesthesia.
Highly controlled vascular syringes for pericardiocentesis.
Ricciardi, Mark; Roldan, Carlos; Sibbitt, Randy; Sibbitt, Wilmer; Michael, Adrian; Palmer, Dennis
2010-12-01
The present study determined the utility and needle control characteristics of highly controlled vascular syringes for image-guided pericardiocentesis. Vascular syringes have been integrated into invasive cardiovascular procedures with improved patient safety, but to date have not been used in pericardiocentesis. To address this issue, we determined the method of use of vascular syringes for pericardiocentesis. A vascular syringe with reciprocating plungers, the reciprocating procedure device (RPD syringe), replaced the corresponding 10 ml and 20 ml conventional syringes in a standard pericardiocentesis tray. The vascular syringe is controlled with one hand, and can either aspirate or inject by pushing the corresponding aspiration or injection plunger. Four hundred and thirty seven subjects underwent vascular syringe procedures. The linear displacement method was used to precisely measure control of the needle tip in millimeters (mm) in vascular syringes compared to conventional syringes in 20 individual operators. Relative to the corresponding 10 ml and 20 ml conventional syringes, vascular syringes significantly reduced unintended forward penetration of the needle tip by 44% (7.0 ± 4.3 mm; p < 0.0001) and 53% (10.1 ± 5.5 mm; p < 0.0001), respectively, and reduced unintended retraction of the needle by 56% (2.7 ± 2.2 mm; p < 0.001) and 60% (3.5 ± 2.5 mm; p < 0.001), respectively. During pericardiocentesis, the mechanical syringe permitted facile one-handed aspiration and maintained the operator's ability to clear the needle. In the 437 vascular syringe procedures, there were no complications, with an estimated cost savings of $10-65 per procedure. Vascular syringes improve needle control in pericardiocentesis, promote patient safety and permit one-handed aspiration and injection.
Haapasalo, Markus; Shen, Ya; Wang, Zhejun; Park, Ellen; Curtis, Allison; Patel, Payal; Vandrangi, Prashanthi
2016-09-01
The purpose of this study is to compare pressures at the apical foramen created by conventional syringe irrigation and the GentleWave™ System, which releases high-velocity degassed irrigants to the pulp chamber and uses broad-spectrum sound energy for cleaning. The apical pressure generated during irrigation was measured for palatal and distobuccal root canals of four extracted maxillary molars after no instrumentation, minimal instrumentation to a size #15/.04, instrumentation to a size #40/.04 taper, and after perforating the apical foramen to size #40. The root canals opened into an air-tight custom fixture coupled to a piezoresistive pressure transducer. Apical pressures were measured for the GentleWave™ System and syringe-needle irrigation at different irrigant flow rates, with the needle tip at 1 and 3 mm from the apical foramen using 30-gauge (G) open-ended or side-vented safety tip needles. The GentleWave™ System generated negative apical pressures (P < 0.001 compared with syringe irrigation); the mean pressures were between -13.07 and -17.19 mmHg. The 30 G needles could not reach the 1 and 3 mm from the working length in uninstrumented and 1 mm in minimally instrumented canals. The mean positive pressures between 6.46 and 110.34 mmHg were measured with needle irrigation depending on the flow rate, needle insertion depth, and size of the root canal. The GentleWave™ System creates negative pressure at the apical foramen during root canal cleaning irrespective of the size of canal instrumentation. Positive apical pressures were measured for syringe irrigation. Negative pressure during irrigation contributes to improved safety as compared to high-positive pressure.
Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2012-04-15
Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parametersmore » at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.« less
Patel, Priya; Wada, Hironobu; Hu, Hsin-Pei; Hirohashi, Kentaro; Kato, Tatsuya; Ujiie, Hideki; Ahn, Jin Young; Lee, Daiyoon; Geddie, William; Yasufuku, Kazuhiro
2017-04-01
Endobronchial ultrasonography (EBUS)-guided transbronchial needle aspiration allows for sampling of mediastinal lymph nodes. The external diameter, rigidity, and angulation of the convex probe EBUS renders limited accessibility. This study compares the accessibility and transbronchial needle aspiration capability of the prototype thin convex probe EBUS against the convex probe EBUS in human ex vivo lungs rejected for transplant. The prototype thin convex probe EBUS (BF-Y0055; Olympus, Tokyo, Japan) with a thinner tip (5.9 mm), greater upward angle (170 degrees), and decreased forward oblique direction of view (20 degrees) was compared with the current convex probe EBUS (6.9-mm tip, 120 degrees, and 35 degrees, respectively). Accessibility and transbronchial needle aspiration capability was assessed in ex vivo human lungs declined for lung transplant. The distance of maximum reach and sustainable endoscopic limit were measured. Transbronchial needle aspiration capability was assessed using the prototype 25G aspiration needle in segmental lymph nodes. In all evaluated lungs (n = 5), the thin convex probe EBUS demonstrated greater reach and a higher success rate, averaging 22.1 mm greater maximum reach and 10.3 mm further endoscopic visibility range than convex probe EBUS, and could assess selectively almost all segmental bronchi (98% right, 91% left), demonstrating nearly twice the accessibility as the convex probe EBUS (48% right, 47% left). The prototype successfully enabled cytologic assessment of subsegmental lymph nodes with adequate quality using the dedicated 25G aspiration needle. Thin convex probe EBUS has greater accessibility to peripheral airways in human lungs and is capable of sampling segmental lymph nodes using the aspiration needle. That will allow for more precise assessment of N1 nodes and, possibly, intrapulmonary lesions normally inaccessible to the conventional convex probe EBUS. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Keskin, Uğur; Karasahin, Kazim Emre; Ulubay, Mustafa; Fidan, Ulaş; Gungor, Sadettin; Ergun, Ali
2015-11-01
Intrauterine fetal transfusion needs extensive experience and requires excellent eye-hand coordination, good equipment and experienced team workers to achieve success. While the needle is in the umbilical vein, an assistant withdraws and/or transfuses blood. The needle point should be kept still to prevent lacerations and dislodging. We propose a simple set for Intrauterine Fetal blood transfusion is constructed by readily available materials in every clinic to minimize needle tip movement and movements during syringe attachments and withdrawals during the intrauterine fetal transfusion. This makes possible to withdraw fetal blood sample, and to transfuse blood with minimal intervention.
System for Manipulating Drops and Bubbles Using Acoustic Radiation Pressure
NASA Technical Reports Server (NTRS)
Oeftering, Richard C. (Inventor)
1999-01-01
The manipulation and control of drops of liquid and gas bubbles is achieved using high intensity acoustics in the form of and/or acoustic radiation pressure and acoustic streaming. generated by a controlled wave emission from a transducer. Acoustic radiation pressure is used to deploy or dispense drops into a liquid or a gas or bubbles into a liquid at zero or near zero velocity from the discharge end of a needle such as a syringe needle. Acoustic streaming is useful in manipulating the drop or bubble during or after deployment. Deployment and discharge is achieved by focusing the acoustic radiation pressure on the discharge end of the needle, and passing the acoustic waves through the fluid in the needle. through the needle will itself, or coaxially through the fluid medium surrounding the needle. Alternatively, the acoustic waves can be counter-deployed by focusing on the discharge end of the needle from a transducer axially aligned with the needle, but at a position opposite the needle, to prevent premature deployment of the drop or bubble. The acoustic radiation pressure can also be used for detecting the presence or absence of a drop or a bubble at the tip of a needle or for sensing various physical characteristics of the drop or bubble such as size or density.
Transillumination for needle localization in the larynx.
Hoffman, Henry T; Dailey, Seth H; Bock, Jonathan M; Thibeault, Susan L; McCulloch, Timothy M
2015-10-01
Transillumination through laryngeal soft tissue may be used to direct percutaneous transcricothyroid membrane subepithelial needle placement in the larynx. Cadaver simulation (canine and human). Lighted devices, including sialendoscopes and fiberoptic cables, were tested as transilluminating obturators in trocars and needles through multiple studies to identify appropriate illumination, monitoring, and equipment for successful localization of needle/trocar tips placed within laryngeal tissue. Lighted 250-micron fiberoptic cables within 23-gauge needles were successfully placed percutaneously through the cricothyroid membrane and maneuvered submucosally into Reinke's space, the midlateral vocal fold, and through the thyroarytenoid gap with monitoring via flexible transnasal laryngoscopy. Technical adaptations in the course of study permitted successful simulation of clinical use in full cadaver study for accurate injection laryngoplasty, confirmed by laryngeal dissection following collagen injection. Small caliber fiberoptic cables are useful as transilluminating obturators to accurately direct needle position within laryngeal tissue. Clinical application of this new technique is anticipated to improve the accuracy of percutaneous needle localization in the larynx, as well as to assist in directed instrumentation of the larynx from an external approach. N/A. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Semicircular thermocouple needle depth gauge for cryoprocedures.
Pappenfort, R B
1981-06-01
A semicircular thermocouple needle depth gauge made of an aluminum alloy drilled with tracks at different angles to place thermocouple needles at various depths below the surface is described herein. Its shape offers definite advantages over circular jigs (templates) when doing cryoexperimentation and when used clinically. The material of which it is made is more durable than plastic. Grommets that firmly snap in place within the inner rim of the instrument permit accurate placement of liquid gas spray, cryoprobes, and other applicators directly over the thermocouple needle tips. This is of special importance when doing cryoexperiments. Furthermore, with this design, the advancing ice front and possible liquid gas runoff are more easily seen. By using both halves it is suitable for monitoring the temperature when freezing large tumors at two different sites and a different depths.
LLOYD, Adam; NAVARRETE, Geraldine; MARCHESAN, Melissa Andreia; CLEMENT, David
2016-01-01
ABSTRACT Objective This study compared the effectiveness of Er:YAG laser-activated irrigation (PIPS), passive ultrasonic irrigation (PUI) with EndoUltra and standard needle irrigation (SNI) in the removal of calcium hydroxide [Ca(OH)2] from the mesial roots of Weine Type II mandibular molars. Material and Methods Thirty mandibular molars were screened by µCT for the presence of mesial roots with complex intra-canal anatomy and a common apical foramen. The teeth were enlarged to a standardized 25/.06 preparation and filled with Ca(OH)2 paste. Specimens were divided into three groups (n=10) according to the technique used for Ca(OH)2 removal: PIPS, at 15 Hz and 20 mJ using a 9 mm long, 600 µm diameter tip; PUI using a 15/.02 tip; and SNI (30 Ga. side-vented needle). Equal volumes of 8.25% NaOCl and 17% EDTA were used in all groups. µCT was used to measure the initial amount of Ca(OH)2 present and to assess the residual volume of Ca(OH)2 following each irrigation protocol. Data were analyzed using Tukey HSD and Kruskal-Wallis tests (α=5%). Results The mean volume of Ca(OH)2 before removal was significantly higher in the coronal third than in the middle and apical third (p<0.001). Ca(OH)2 was similarly removed from the coronal and middle thirds with the three methods used (p>0.05). PIPS (median 0%; IQR: 0-0) showed significant higher Ca(OH)2 removal in the apical third than PUI (median 100%, IQR: 85-100) and SNI (median 47%; IQR: 16-72) (p<0.001). Conclusions PIPS laser-activation was more effective for the removal of Ca(OH)2 from mesial roots of mandibular molars with Weine Type II canal configurations than PUI with EndoUltra and SNI. PMID:28076457
Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy
Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter
2016-01-01
We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122
Cadaveric and Ultrasonographic Validation of Needling Placement in the Cervical Multifidus Muscle.
Fernández-de-Las-Peñas, César; Mesa-Jiménez, Juan A; Paredes-Mancilla, Jose A; Koppenhaver, Shane L; Fernández-Carnero, Samuel
2017-06-01
The aim of this study was to determine if a needle is able to reach the cervical multifidus during the application of dry needling or acupuncture. Dry needling and ultrasound imaging of cervical multifidi was conducted on 5 patients (age: 32 ± 5 years) with mechanical neck pain and on 2 fresh cadavers (age: 64 ± 1 years). Dry needling was done using a needle of 40 mm in length inserted perpendicular to the skin about 1 cm lateral to the spinous process at C3-C4. The needle was advanced from a posterior to anterior direction into the cervical multifidus with a slight inferior-medial angle (approximately 10°) to reach the vertebra lamina. For the cadaveric study, the multifidus was isolated by carefully resecting the superficial posterior cervical muscles: trapezius, splenius, and semispinalis. For the ultrasonographic study, a convex transducer was placed transversely over C3-C4 after the insertion of the needle into the muscle. The results of both the cadaveric and ultrasonic studies found that the needle does pierce the cervical multifidus muscle during insertion and that the tip of the needle rests properly against the vertebral laminae, thereby guarding the sensitive underlying spinal structures from damage. This anatomical and ultrasound imaging study supports that dry needling of the cervical multifidus could be conducted clinically. Copyright © 2017. Published by Elsevier Inc.
Rossa, Carlos; Lehmann, Thomas; Sloboda, Ronald; Usmani, Nawaid; Tavakoli, Mahdi
2017-08-01
Global modelling has traditionally been the approach taken to estimate needle deflection in soft tissue. In this paper, we propose a new method based on local data-driven modelling of needle deflection. External measurement of needle-tissue interactions is collected from several insertions in ex vivo tissue to form a cloud of data. Inputs to the system are the needle insertion depth, axial rotations, and the forces and torques measured at the needle base by a force sensor. When a new insertion is performed, the just-in-time learning method estimates the model outputs given the current inputs to the needle-tissue system and the historical database. The query is compared to every observation in the database and is given weights according to some similarity criteria. Only a subset of historical data that is most relevant to the query is selected and a local linear model is fit to the selected points to estimate the query output. The model outputs the 3D deflection of the needle tip and the needle insertion force. The proposed approach is validated in ex vivo multilayered biological tissue in different needle insertion scenarios. Experimental results in five different case studies indicate an accuracy in predicting needle deflection of 0.81 and 1.24 mm in the horizontal and vertical lanes, respectively, and an accuracy of 0.5 N in predicting the needle insertion force over 216 needle insertions.
Needle Steering in 3-D Via Rapid Replanning
Patil, Sachin; Burgner, Jessica; Webster, Robert J.; Alterovitz, Ron
2014-01-01
Steerable needles have the potential to improve the effectiveness of needle-based clinical procedures such as biopsy and drug delivery by improving targeting accuracy and reaching previously inaccessible targets that are behind sensitive or impenetrable anatomical regions. We present a new needle steering system capable of automatically reaching targets in 3-D environments while avoiding obstacles and compensating for real-world uncertainties. Given a specification of anatomical obstacles and a clinical target (e.g., from preoperative medical images), our system plans and controls needle motion in a closed-loop fashion under sensory feedback to optimize a clinical metric. We unify planning and control using a new fast algorithm that continuously replans the needle motion. Our rapid replanning approach is enabled by an efficient sampling-based rapidly exploring random tree (RRT) planner that achieves orders-of-magnitude reduction in computation time compared with prior 3-D approaches by incorporating variable curvature kinematics and a novel distance metric for planning. Our system uses an electromagnetic tracking system to sense the state of the needle tip during the procedure. We experimentally evaluate our needle steering system using tissue phantoms and animal tissue ex vivo. We demonstrate that our rapid replanning strategy successfully guides the needle around obstacles to desired 3-D targets with an average error of less than 3 mm. PMID:25435829
Precision grid and hand motion for accurate needle insertion in brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2011-08-15
Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on themore » measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.« less
The effects of needle deformation during lumbar puncture.
Özdemir, Hasan Hüseyin; Demir, Caner F; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref
2015-01-01
The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.
Note: High temperature pulsed solenoid valve.
Shen, Wei; Sulkes, Mark
2010-01-01
We have developed a high temperature pulsed solenoid valve with reliable long term operation to at least 400 degrees C. As in earlier published designs, a needle extension sealing a heated orifice is lifted via solenoid actuation; the solenoid is thermally isolated from the heated orifice region. In this new implementation, superior sealing and reliability were attained by choosing a solenoid that produces considerably larger lifting forces on the magnetically actuated plunger. It is this property that facilitates easily attainable sealing and reliability, albeit with some tradeoff in attainable gas pulse durations. The cost of the solenoid valve employed is quite low and the necessary machining quite simple. Our ultimate level of sealing was attained by making a simple modification to the polished seal at the needle tip. The same sealing tip modification could easily be applied to one of the earlier high T valve designs, which could improve the attainability and tightness of sealing for these implementations.
Real-time MRI-guided needle intervention for cryoablation: a phantom study
NASA Astrophysics Data System (ADS)
Gao, Wenpeng; Jiang, Baichuan; Kacher, Dan F.; Fetics, Barry; Nevo, Erez; Lee, Thomas C.; Jayender, Jagadeesan
2017-03-01
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle's tip and out for adjusting the needle's trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle's position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 +/-1.60 mm, 4.11 +/- 1.77 mm and 1.91 - 1.10 mm, respectively.
Chan, Edwin; Maa, Yuh-Fun; Overcashier, David; Hsu, Chung C
2011-01-01
This study is to investigate the effect of headspace air pressure in pre-filled syringes on liquid leak (dripping) from the syringe needle upon needle shield removal. Drip tests to measure drip quantity were performed on syringes manually filled with 0.5 or 1.0 mL of various aqueous solutions. Parameters assessed included temperature (filling and test), bulk storage conditions (tank pressure and the type of the pressurized gas), solution composition (pure water, 0.9% sodium chloride, and a monoclonal antibody formulation), and testing procedures. A headspace pressure analyzer was used to verify the drip test method. Results suggested that leakage is indeed caused by headspace pressure increase, and the temperature effect (ideal gas expansion) is a major, but not the only, factor. The dissolved gases in the liquid bulk prior to or during filling may contribute to leakage, as these gases could be released into the headspace due to solubility changes (in response to test temperature and pressure conditions) and cause pressure increase. Needle shield removal procedures were found to cause dripping, but liquid composition played little role. Overall, paying attention to the processing history (pressure and temperature) of the liquid bulk is the key to minimize leakage. The headspace pressure could be reduced by decreasing liquid bulk storage pressure, filling at a higher temperature, or employing lower solubility gas (e.g., helium) for bulk transfer and storage. Leakage could also be mitigated by simply holding the syringe needle pointing upward during needle shield removal. Substantial advances in pre-filled syringe technology development, particularly in syringe filling accuracy, have been made. However, there are factors, as subtle as how the needle shield (or tip cap) is removed, that may affect dosing accuracy. We recently found that upon removal of the tip cap from a syringe held vertically with needle pointed downwards, a small amount of solution, up to 3-4% of the 1 mL filled volume or higher for filled volume of <1 mL, leaked out from the needle. This paper identified the root causes of this problem and offered solutions from the perspectives of the syringe fill process and the end user procedure. The readers will benefit from this paper by understanding how each process step prior to and during syringe filling may affect delivery performance of the pre-filled syringe device.
Li, Hua; Wei, Chang-Yan; Liu, Chun-Xia; Shen, Xian-Hao; Chen, Zhen-Cheng
2014-07-01
A new needle-to-cylinder electrode structure was designed to realize the stable glow discharge in ambient air. The stainless steel needle tip with diameter 56.4 microm and the copper cylinder with diameter 4mm were chosen as the cathode and the anode respectively, which were kept parallel by accurate mechanical structure. In the condition that the distance between the needle and the cylinder is 2 mm, the ballasting resistor is 10 M(omega), the discharge resistor is 10 M(omega), the testing resistor is 1 k(omega), and the discharge voltage is -2 740 V, without air flow in ambient air and at room temperature, the stable glow discharge between the needle and the cylinder was realized. Three different discharge modes can be observed: corona discharge, glow discharge and spark, which were verified by the discharge waveform stored in the oscilloscope, and the discharge pictures were recorded by digital camera. The needle-to-cylinder electrode structure is easy to fabricate by the MEMS technology, which can be used as the ion source of the portable analyzing instruments.
Scaled-Up Nonequilibrium Air Plasmas
2009-10-01
surrounding gas. So if we put a needle electrode with DC corona discharge directly into the MW plasma (Figure 7), N2* is produced by electron excitation but...transitions When a high voltage of a few kV is applied to the point electrode , a corona discharge appears on the point, further developing to streamer... electrode tips but with the smaller difference between the field in the middle and near the tips than in corona . This transition to TS pulse probably
Marticorena, Rosa M; Dacouris, Niki; Donnelly, Sandra M
2018-05-01
Hemodialysis requires needle insertions every treatment. Needle injury (mechanical or hemodynamic) may cause complications (aneurysms/stenosis) that compromise dialysis delivery requiring interventions. Metal needles have a sharp slanted "V"-shaped cutting tip; plastic cannulae have a dull round tip and four side holes. Preliminary observations demonstrated a difference in intradialytic blood flow images and mean Doppler velocities at cannulation sites between the two devices. Complications from mechanical and hemodynamic trauma requiring interventions were compared in each group. In all, 33 patients (13 females and 17 new accesses) were randomized to metal group (n = 17) and plastic group (n = 16). Mechanical trauma was minimized by having five nurses performing ultrasound-guided cannulations. Complications were identified by the clinician and addressed by the interventionalists, both blinded to study participation. Patients were followed for up to 12 months. Baseline characteristics were not significant. Procedures to treat complications along cannulation segments increased from 0.41 to 1.29 per patient (metal group) and decreased from 1.25 to 0.69 per patient (plastic group; p = 0.004). The relative risks of having an intervention (relative risk = 1.5, 95% confidence interval = 0.88-2.67) and having an infiltration during hemodialysis (relative risk = 2.26, 95% confidence interval = 1.03-4.97) were higher for metal needles. Time to first intervention trended in favor of plastic cannula (p = 0.069). Cost of supplies for these interventions was approximately CAD$20,000 lower for the plastic group. Decreased burden of illness related to cannulation (less infiltrations during hemodialysis) and Qb were associated with plastic cannulae. Decreased procedure costs were suggested during the study period in the plastic group.
Needle placement for piriformis injection using 3-D imaging.
Clendenen, Steven R; Candler, Shawn A; Osborne, Michael D; Palmer, Scott C; Duench, Stephanie; Glynn, Laura; Ghazi, Salim M
2013-01-01
Piriformis syndrome is a pain syndrome originating in the buttock and is attributed to 6% - 8% of patients referred for the treatment of back and leg pain. The treatment for piriformis syndrome using fluoroscopy, computed tomography (CT), electromyography (EMG), and ultrasound (US) has become standard practice. The treatment of Piriformis Syndrome has evolved to include fluoroscopy and EMG with CT guidance. We present a case study of 5 successful piriformis injections using 3-D computer-assisted electromagnet needle tracking coupled with ultrasound. A 6-degree of freedom electromagnetic position tracker was attached to the ultrasound probe that allowed the system to detect the position and orientation of the probe in the magnetic field. The tracked ultrasound probe was used to find the posterior superior iliac spine. Subsequently, 3 points were captured to register the ultrasound image with the CT or magnetic resonance image scan. Moreover, after the registration was obtained, the navigation system visualized the tracked needle relative to the CT scan in real-time using 2 orthogonal multi-planar reconstructions centered at the tracked needle tip. Conversely, a recent study revealed that fluoroscopically guided injections had 30% accuracy compared to ultrasound guided injections, which tripled the accuracy percentage. This novel technique exhibited an accurate needle guidance injection precision of 98% while advancing to the piriformis muscle and avoiding the sciatic nerve. The mean (± SD) procedure time was 19.08 (± 4.9) minutes. This technique allows for electromagnetic instrument tip tracking with real-time 3-D guidance to the selected target. As with any new technique, a learning curve is expected; however, this technique could offer an alternative, minimizing radiation exposure.
A comparison of injection pain and postoperative pain of two intraosseous anesthetic techniques.
Gallatin, Juliane; Nusstein, John; Reader, Al; Beck, Mike; Weaver, Joel
2003-01-01
The purpose of this prospective, randomized, blinded study was to compare injection pain and postoperative pain of an apical primary X-Tip intraosseous technique to a coronal primary Stabident intraosseous technique in mandibular first molars. Using a repeated-measures design, 41 subjects randomly received 2 primary intraosseous injections at 2 separate appointments. Using a site distal to the mandibular first molar for both injections, the subjects received 1.8 mL of 2% lidocaine with 1: 100,000 epinephrine administered with the X-Tip system using an apical location in alveolar mucosa or 1.8 mL of 2% lidocaine with 1: 100,000 epinephrine administered with the Stabident system using a coronal location in attached gingiva. The pain of infiltration, perforation, needle insertion, solution deposition, mock or actual guide sleeve removal and postoperative pain were recorded on a Heft-Parker visual analogue scale (VAS) scale for the 2 intraosseous systems. The results demonstrated that the apical primary X-Tip intraosseous technique was not statistically different (P > .05) from the coronal primary Stabident technique regarding pain ratings of infiltration, perforation, needle insertion, solution deposition, mock or actual guide sleeve removal and postoperative pain (at the time subjective anesthesia wore off). However, on postoperative days 1 through 3, significantly (P < .05) more males experienced postoperative pain with the X-Tip system than with the Stabident system.
Tang, Lina; Du, Danxin; Yang, Fan; Liang, Zhong; Ning, Yong; Wang, Hua; Zhang, Guo-Jun
2015-01-01
We report a unique nanosensing platform by combining modern nanotechnology with traditional acupuncture needle to prepare graphene-modified acupuncture needle (G-AN), and using it for sensitive detection of neurotransmitters via electrochemistry. An electrochemical deposition method was employed to deposit Au nanoparticles (AuNPs) on the tip surface of the traditional acupuncture needle, while the other part of the needle was coated with insulation paste. Subsequently, the G-AN was obtained by cyclic voltammetry reduction of a graphene oxide solution on the surface of the AuNPs. To investigate the sensing property of the G-AN, pH dependence was measured by recording the open circuit potential in the various pH buffer solutions ranging from 2.0 to 10.0. What’s more, the G-AN was further used for detection of dopamine (DA) with a limit of detection of 0.24 μM. This novel G-AN exhibited a good sensitivity and selectivity, and could realize direct detection of DA in human serum. PMID:26112773
Boutsioukis, C; Lambrianidis, T; Kastrinakis, E
2009-02-01
To study using computer simulation the effect of irrigant flow rate on the flow pattern within a prepared root canal, during final irrigation with a syringe and needle. Geometrical characteristics of a side-vented endodontic needle and clinically realistic flow rate values were obtained from previous and preliminary studies. A Computational Fluid Dynamics (CFD) model was created using FLUENT 6.2 software. Calculations were carried out for five selected flow rates (0.02-0.79 mL sec(-1)) and velocity and turbulence quantities along the domain were evaluated. Irrigant replacement was limited to 1-1.5 mm apical to the needle tip for all flow rates tested. Low-Reynolds number turbulent flow was detected near the needle outlet. Irrigant flow rate affected significantly the flow pattern within the root canal. Irrigation needles should be placed to within 1 mm from working length to ensure fluid exchange. Turbulent flow of irrigant leads to more efficient irrigant replacement. CFD represents a powerful tool for the study of irrigation.
NASA Astrophysics Data System (ADS)
Tang, Lina; Du, Danxin; Yang, Fan; Liang, Zhong; Ning, Yong; Wang, Hua; Zhang, Guo-Jun
2015-06-01
We report a unique nanosensing platform by combining modern nanotechnology with traditional acupuncture needle to prepare graphene-modified acupuncture needle (G-AN), and using it for sensitive detection of neurotransmitters via electrochemistry. An electrochemical deposition method was employed to deposit Au nanoparticles (AuNPs) on the tip surface of the traditional acupuncture needle, while the other part of the needle was coated with insulation paste. Subsequently, the G-AN was obtained by cyclic voltammetry reduction of a graphene oxide solution on the surface of the AuNPs. To investigate the sensing property of the G-AN, pH dependence was measured by recording the open circuit potential in the various pH buffer solutions ranging from 2.0 to 10.0. What’s more, the G-AN was further used for detection of dopamine (DA) with a limit of detection of 0.24 μM. This novel G-AN exhibited a good sensitivity and selectivity, and could realize direct detection of DA in human serum.
Reliability of Waveform Analysis as an Adjunct to Loss of Resistance for Thoracic Epidural Blocks.
Leurcharusmee, Prangmalee; Arnuntasupakul, Vanlapa; Chora De La Garza, Daniel; Vijitpavan, Amorn; Ah-Kye, Sonia; Saelao, Abhidej; Tiyaprasertkul, Worakamol; Finlayson, Roderick J; Tran, De Q H
2015-01-01
The epidural space is most commonly identified with loss of resistance (LOR). Although sensitive, LOR lacks specificity, as cysts in interspinous ligaments, gaps in ligamentum flavum, paravertebral muscles, thoracic paravertebral spaces, and intermuscular planes can yield nonepidural LOR. Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for LOR. When the needle is correctly positioned inside the epidural space, measurement of the pressure at its tip results in a pulsatile waveform. In this observational study, we set out to assess the sensitivity, specificity, as well as positive and negative predictive values of EWA for thoracic epidural blocks. We enrolled a convenience sample of 160 patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures. The choice of patient position (sitting or lateral decubitus), approach (midline or paramedian), and LOR medium (air or normal saline) was left to the operator (attending anesthesiologist, fellow, or resident). After obtaining a satisfactory LOR, the operator injected 5 mL of normal saline through the epidural needle. A sterile tubing, connected to a pressure transducer, was attached to the needle to measure the pressure at the needle tip. A 4-mL bolus of lidocaine 2% with epinephrine 5 μg/mL was then administered and, after 10 minutes, the patient was assessed for sensory blockade to ice. The failure rate (incorrect identification of the epidural space with LOR) was 23.1%. Of these 37 failed epidural blocks, 27 provided no sensory anesthesia at 10 minutes. In 10 subjects, the operator was unable to thread the catheter through the needle. When compared with the ice test, the sensitivity, specificity, and positive and negative predictive values of EWA were 91.1%, 83.8%, 94.9%, and 73.8%, respectively. Epidural waveform analysis (with pressure transduction through the needle) provides a simple adjunct to LOR for thoracic epidural blocks. Although its use was devoid of complications, further confirmatory studies are required before its routine implementation in clinical practice.
The Ultrasound-Guided Retroclavicular Block: A Prospective Feasibility Study.
Charbonneau, Jasmin; Fréchette, Yannick; Sansoucy, Yanick; Echave, Pablo
2015-01-01
The aim of this feasibility study was to determine the success rate (sensory and surgical) of the novel retroclavicular block and to thoroughly describe the technique. In addition, needle tip and shaft visibility, needling time, procedural discomfort, motor block success rate, patient satisfaction at 48-hour follow-up, and complications were also recorded. Fifty patients scheduled for distal upper limb surgery received an in-plane, single-shot, ultrasound-guided retroclavicular block with 40 mL of mepivacaine 1.5% with epinephrine 2.5 μg/mL. Block success was defined as a sensory score of 10/10 for the 5 nerves supplying the distal upper limb at 30 minutes. Surgical success, needle visibility, needling time, axillary artery depth, motor block rate, patient discomfort with technique, satisfaction at 48 hours, and complications were also recorded. All blocks were video-recorded and timed for further independent assessment. A chest x-ray was obtained before discharge. Forty-five patients had a total sensory score of 10/10 at 30 minutes (90% success rate). Surgical success rate was 96%. Mean needling time was 3.77 minutes (25th-75th percentiles, 2.90-6.53 minutes) with a mean axillary artery depth of 3.1 ± 0.7 cm. Procedure-related discomfort (mean visual analog scale, 1.9 ± 1.2) was low. Mean 48-hour patient satisfaction rate (9.2 ± 1.1), mean needle tip (Likert scale, 3.0 ± 0.9), and shaft visibility (3.9 ± 0.9) were high. One vascular puncture and two transient paresthesias were recorded. No pneumothorax was revealed by chest x-ray. In this study, the novel retroclavicular block offered a quick, safe, and reliable alternative for distal arm block. Further studies, comparing this approach with the classic infraclavicular block, are required to validate its efficacy, safety, and reliability.
NASA Astrophysics Data System (ADS)
Hozumi, Naohiro; Nishioka, Koji; Suematsu, Takeshi; Murakami, Yoshinobu; Nagao, Masayuki; Sakata, Hiroshi
Feasibility of self-healing insulation system was studied. A silicone rubber without filler was mounted on a glass substrate with a needle electrode. An ac voltage with 4 kV in rms was applied. The voltage was cut off when the tree had propagated into 150 micrometers in length. After the cut-off, the partial discharge inception voltage was periodically observed. The partial discharge inception voltage had once reduced into as low as 2 kV. However, it gradually increased with time, and finally exceeded the tree inception voltage (4 kV) when 30 - 60 hours had passed. It was also observed by optical microscope that the tree gradually disappeared in parallel with the recovery of the partial discharge inception voltage. The same phenomenon was observed even if 1 kV ac voltage had been continuously applied during the process of the recovery. A simulation using a needle-shaped void was performed in order to clarify the mechanism of the self-healing effect. It was observed that the tip of the needle-shaped void gradually got wet with a liquid material. It would be the result of "bleed-out" of the low molecular component included in the rubber. The tip of the void was finally filled with the liquid, however, the rest of the needle-shaped void stayed without being filled. In this type of tree, it was suggested that the self-healing effect is expected if the diameter of the tree did not exceed ca. 5 micrometers.
Borghi, Battista; Agnoletti, Vanni; Ricci, Alessandro; van Oven, Hanna; Montone, Nicoletta; Casati, Andrea
2004-05-01
We evaluated the effects of turning the tip of the Tuohy needle 45 degrees toward the operative side before threading the epidural catheter (45 degrees -rotation group, n = 24) as compared to a conventional insertion technique with the tip of the Tuohy needle oriented at 90 degrees cephalad (control group, n = 24) on the distribution of 10 mL of 0.75% ropivacaine with 10 microg sufentanil in 48 patients undergoing total hip replacement. The catheter was introduced 3 to 4 cm beyond the tip of the Tuohy needle. A blinded observer recorded sensory and motor blocks on both sides, quality of analgesia, and volumes of local anesthetic used during the first 48 h of patient-controlled epidural analgesia. Readiness to surgery required 21 +/- 6 min in the control group and 17 +/- 7 min in the 45 degree-rotation group (P > 0.50). The maximum sensory level reached on the operative side was T10 (T10-7) in the control group and T9 (T10-6) in the 45 degree-rotation group (P > 0.50); whereas the maximum sensory level reached on the nonoperative side was T10 (T12-9) in the control group and L3 (L5-T12) in the 45 degree-rotation group (P = 0.0005). Complete motor blockade of the operative limb was achieved earlier in the 45 degree-rotation than in the control group, and motor block of the nonoperative side was more intense in patients in the control group. Two-segment regression of sensory level on the surgical side was similar in the two groups, but occurred earlier on the nonoperative side in the 45 degree-rotation group (94 +/- 70 min) than in the control group (178 +/- 40 min) (P = 0.0005). Postoperative analgesia was similar in the 2 groups, but the 45 degree-rotation group consumed less local anesthetic (242 +/- 35 mL) than the control group (297 +/- 60 mL) (P = 0.0005). We conclude that the rotation of the Tuohy introducer needle 45 degrees toward the operative side before threading the epidural catheter provides a preferential distribution of sensory and motor block toward the operative side, reducing the volume of local anesthetic solution required to maintain postoperative analgesia. Turning the Tuohy introducer needle 45 degrees toward the operative side before threading the epidural catheter is a simple maneuver that produces a preferential distribution of epidural anesthesia and analgesia toward the operative side, minimizing the volume of local anesthetic required to provide adequate pain relief after total hip arthroplasty.
Ghaleb, Ahmed; Khorasani, Arjang; Mangar, Devanand
2012-01-01
Since August Bier reported the first case in 1898, post-dural puncture headache (PDPH) has been a problem for patients following dural puncture. Clinical and laboratory research over the last 30 years has shown that use of smaller-gauge needles, particularly of the pencil-point design, are associated with a lower risk of PDPH than traditional cutting point needle tips (Quincke-point needle). A careful history can rule out other causes of headache. A postural component of headache is the sine qua non of PDPH. In high-risk patients < 50 years, post-partum, in the event a large-gauge needle puncture is initiated, an epidural blood patch should be performed within 24–48 hours of dural puncture. The optimum volume of blood has been shown to be 12–20 mL for adult patients. Complications caused by autologous epidural blood patching (AEBP) are rare. PMID:22287846
Ghaleb, Ahmed
2010-01-01
Postdural puncture headache (PDPH) has been a problem for patients, following dural puncture, since August Bier reported the first case in 1898. His paper discussed the pathophysiology of low-pressure headache resulting from leakage of cerebrospinal fluid (CSF) from the subarachnoid to the epidural space. Clinical and laboratory research over the last 30 years has shown that use of small-gauge needles, particularly of the pencil-point design, is associated with a lower risk of PDPH than traditional cutting point needle tips (Quincke-point needle). A careful history can rule out other causes of headache. A postural component of headache is the sine qua non of PDPH. In high-risk patients , for example, age < 50 years, postpartum, large-gauge needle puncture, epidural blood patch should be performed within 24–48 h of dural puncture. The optimum volume of blood has been shown to be 12–20 mL for adult patients. Complications of AEBP are rare. PMID:20814596
25-gauge fibered-needle for label-free fluorescence analysis of breast masses: a first in vivo study
NASA Astrophysics Data System (ADS)
Toullec, Alexis; Mathieu, Marie-Christine; Benoit, Charlotte; Farcy, René; Tourasse, Christophe; Boisserie-Lacroix, Martine; Fontaine-Aupart, Marie-Pierre; Delaloge, Suzette; Balleyguier, Corinne
2018-02-01
Breast lesions diagnosis and characterization need additional cost-effective techniques to avoid unnecessary invasive procedures, such as core needle biopsies, in the case of benign tumors. Endogenous fluorescence is an effective method to highlight in situ metabolic and/or structural changes between cancerous and non-cancerous lesions. In this context, we developed an original set-up, consisting of a 405 nm laser diode transmitting light through a 25 Gauge (0.45 mm x 50mm) 14° sharp fibered needle to excite intranodular fluorophores around the needle tip and providing real-time labelfree fluorescence spectral analysis of lesions from 450 nm to 650 nm. The objective was to help radiologists to classify suspicious masses in vivo and in real-time within the lesion. We reported the results of spectral differences between 14 invasive lobular carcinomas and 6 intraductal papilloma enrolled in a clinical study.
The effects of needle deformation during lumbar puncture
Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref
2015-01-01
Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480
Electrospray of 1-Butyl-3-Methylimidazolium Dicyanamide Under Variable Flow Rate Operations
2014-06-27
cm length. The capillary needle is stainless steel with a tapered tip of 50 μm inner diameter and 3.5 cm length. Both capillaries are commercially...connected. Figure 8 shows the emission current results of a 50 μm stainless - steel tip over the same IL flow rate range as Fig. 5. The emitter... fuming nitric acid, resulting in an ignition delay time of 47 ms, longer than the desired maximumof 5ms.Numerical predictions byBerg andRovey [18,19
Consistency of performance of robot-assisted surgical tasks in virtual reality.
Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N
2009-01-01
The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.
Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.
Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D
2001-10-01
The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.
The keys to successful TIPS in patients with portal vein thrombosis and cavernous transformation.
Lombardo, S; Espejo, J J; Pérez-Montilla, M E; Zurera, L J; González-Galilea, Á
Portal vein thrombosis is a common complication in patients with cirrhosis. Anticoagulation involves a high risk of bleeding secondary to portal hypertension, so placing transjugular intrahepatic portosystemic shunts (TIPS) has become an alternative treatment for portal vein thrombosis. Three strategies for TIPS placement have been reported: 1) portal recanalization and conventional implantation of the TIPS through the jugular vein; 2) portal recanalization through percutaneous transhepatic/transsplenic) access; and (3) insertion of the TIPS between the suprahepatic vein and a periportal collateral vessel without portal recanalization. We describe different materials that can be used as fluoroscopic targets for the TIPS needle and for portal recanalization. This article aims to show the success of TIPS implantation using different combinations of the techniques listed above, which is a good treatment alternative in these patients whose clinical condition makes them difficult to manage, and to show that portal vein thrombosis/cavernous transformation should not be considered a contraindication for TIPS. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Astrophysics Data System (ADS)
Chung, Chieh-Wen; Tsai, May-Jywan; Lin, Peng-Wei; Huang, Ding-Wen; Wang, Kuan-Hsun; Chen, Yu-An; Meng, Hsin-Fei; Zan, Hsiao-Wen; Cheng, Henrich; Tong, Limin; Zhang, Lei; Horng, Sheng-Fu; Hung, Cheng-Hsiung
2018-02-01
A NO sensing tip is made by inserting two parallel optical fibers inside a poly 2-hydroxyethyl methacrylate (PolyHEMA) hydrogel waveguide mixed with the probe molecule 1, 2-Diaminoanthraquinone (DAQ). There is a length difference of 1 mm between the two fibers, and the light has to propagate through the difference from the short fiber to the long fiber. The total cross section area of the active hydrogel waveguide embedded with the fibers is only 3mm x 1.2 mm. For practical use the tip is housed in a needle for mechanical protection and the sensing tip is able to detect aqueous NO concentration around 1 μM with time resolution about 5 minutes. Such a sensing tip can be used to monitor the medical conditions inside the brain after a stroke or a brain injury.
Measurements of lightning rod responses to nearby strikes
NASA Astrophysics Data System (ADS)
Moore, C. B.; Aulich, G. D.; Rison, W.
2000-05-01
Following Benjamin Franklin's invention of the lightning rod, based on his discovery that electrified objects could be discharged by approaching them with a metal needle in hand, conventional lightning rods in the U.S. have had sharp tips. In recent years, the role of the sharp tip in causing a lightning rod to act as a strike receptor has been questioned leading to experiments in which pairs of various sharp-tipped and blunt rods have been exposed beneath thunderclouds to determine the better strike receptor. After seven years of tests, none of the sharp Franklin rods or of the so-called “early streamer emitters” has been struck, but 12 blunt rods with tip diameters ranging from 12.7 mm to 25.4 mm have taken strikes. Our field experiments and our analyses indicate that the strike-reception probabilities of Franklin's rods are greatly increased when their tips are made moderately blunt.
Biodegradable 3D printed polymer microneedles for transdermal drug delivery.
Luzuriaga, Michael A; Berry, Danielle R; Reagan, John C; Smaldone, Ronald A; Gassensmith, Jeremiah J
2018-04-17
Biodegradable polymer microneedle (MN) arrays are an emerging class of transdermal drug delivery devices that promise a painless and sanitary alternative to syringes; however, prototyping bespoke needle architectures is expensive and requires production of new master templates. Here, we present a new microfabrication technique for MNs using fused deposition modeling (FDM) 3D printing using polylactic acid, an FDA approved, renewable, biodegradable, thermoplastic material. We show how this natural degradability can be exploited to overcome a key challenge of FDM 3D printing, in particular the low resolution of these printers. We improved the feature size of the printed parts significantly by developing a post fabrication chemical etching protocol, which allowed us to access tip sizes as small as 1 μm. With 3D modeling software, various MN shapes were designed and printed rapidly with custom needle density, length, and shape. Scanning electron microscopy confirmed that our method resulted in needle tip sizes in the range of 1-55 μm, which could successfully penetrate and break off into porcine skin. We have also shown that these MNs have comparable mechanical strengths to currently fabricated MNs and we further demonstrated how the swellability of PLA can be exploited to load small molecule drugs and how its degradability in skin can release those small molecules over time.
Atmospheric negative corona discharge using a Taylor cone as liquid electrode
NASA Astrophysics Data System (ADS)
Sekine, Ryuto; Shirai, Naoki; Uchida, Satoshi; Tochikubo, Fumiyoshi
2012-10-01
We examined characteristics of atmospheric negative corona discharge using liquid needle cathode. As a liquid needle cathode, we adopted Taylor cone with conical shape. A nozzle with inner diameter of 10 mm is filled with liquid, and a plate electrode is placed at 10 mm above the nozzle. By applying a dc voltage between electrodes, Taylor cone is formed. To change the liquid property, we added sodium dodecyl sulfate to reduce the surface tension, sodium sulfate to increase the conductivity, and polyvinyl alcohol to increase the viscosity, in distilled water. The liquid, with high surface tension such as pure water could not form a Taylor cone. When we reduced surface tension, a Taylor cone was formed and the stable corona discharge was observed at the tip of the cone. When we increased viscosity, a liquid filament protruded from the solution surface was formed and corona discharge was observed along the filament at position 0.7-1.0 mm above from the tip of the cone. Increasing the conductivity resulted in the higher light intensity of corona and the lower corona onset voltage. When we use the metal needle electrode, the corona discharge depends on the voltage and the gap length. Using Taylor cone, different types of discharges were observed by changing the property of the liquid.
NASA Astrophysics Data System (ADS)
Beigi, Parmida; Salcudean, Septimiu E.; Rohling, Robert; Ng, Gary C.
2016-03-01
This paper presents an automatic localization method for a standard hand-held needle in ultrasound based on temporal motion analysis of spatially decomposed data. Subtle displacement arising from tremor motion has a periodic pattern which is usually imperceptible in the intensity image but may convey information in the phase image. Our method aims to detect such periodic motion of a hand-held needle and distinguish it from intrinsic tissue motion, using a technique inspired by video magnification. Complex steerable pyramids allow specific design of the wavelets' orientations according to the insertion angle as well as the measurement of the local phase. We therefore use steerable pairs of even and odd Gabor wavelets to decompose the ultrasound B-mode sequence into various spatial frequency bands. Variations of the local phase measurements in the spatially decomposed input data is then temporally analyzed using a finite impulse response bandpass filter to detect regions with a tremor motion pattern. Results obtained from different pyramid levels are then combined and thresholded to generate the binary mask input for the Hough transform, which determines an estimate of the direction angle and discards some of the outliers. Polynomial fitting is used at the final stage to remove any remaining outliers and improve the trajectory detection. The detected needle is finally added back to the input sequence as an overlay of a cloud of points. We demonstrate the efficiency of our approach to detect the needle using subtle tremor motion in an agar phantom and in-vivo porcine cases where intrinsic motion is also present. The localization accuracy was calculated by comparing to expert manual segmentation, and presented in (mean, standard deviation and root-mean-square error) of (0.93°, 1.26° and 0.87°) and (1.53 mm, 1.02 mm and 1.82 mm) for the trajectory and the tip, respectively.
Li, Pan; Yang, Zhiyong; Jiang, Shan
2018-06-01
Image-guided robot-assisted minimally invasive surgery is an important medicine procedure used for biopsy or local target therapy. In order to reach the target region not accessible using traditional techniques, long and thin flexible needles are inserted into the soft tissue which has large deformation and nonlinear characteristics. However, the detection results and therapeutic effect are directly influenced by the targeting accuracy of needle steering. For this reason, the needle-tissue interactive mechanism, path planning, and steering control are investigated in this review by searching literatures in the last 10 years, which results in a comprehensive overview of the existing techniques with the main accomplishments, limitations, and recommendations. Through comprehensive analyses, surgical simulation for insertion into multi-layer inhomogeneous tissue is verified as a primary and propositional aspect to be explored, which accurately predicts the nonlinear needle deflection and tissue deformation. Investigation of the path planning of flexible needles is recommended to an anatomical or a deformable environment which has characteristics of the tissue deformation. Nonholonomic modeling combined with duty-cycled spinning for needle steering, which tracks the tip position in real time and compensates for the deviation error, is recommended as a future research focus in the steering control in anatomical and deformable environments. Graphical abstract a Insertion force when the needle is inserted into soft tissue. b Needle deflection model when the needle is inserted into soft tissue [68]. c Path planning in anatomical environments [92]. d Duty-cycled spinning incorporated in nonholonomic needle steering [64].
NASA Astrophysics Data System (ADS)
Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron
2017-03-01
Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rusnan, Fara Naila; Mohamad, Khairul Anuar; Seria, Dzul Fahmi Mohd Husin
3,16-bis triisopropylsilylethynyl (Pentacene) (TIPS-Pentacene) compactable interface property is important in order to have a good arrangement of molecular structure. Comparison for TIPS-Pentacene deposited between two different surface layers conducted. 0.1wt% TIPS-Pentacene diluted in chloroform were deposited onto poly(methylmeaclyrate) (PMMA) layered transparent substrates using slide coating method. X-ray diffraction (XRD) used to determine crystallinity of thin films. Series of (00l) diffraction peaks obtained with sharp first peaks (001) for TIPS-Pentacene deposited onto PMMA layer at 5.35° and separation of 16.3 Å. Morphology and surface roughness were carried out using scanning electron microscope (SEM) and surface profilemeter LS500, respectively.TIPS-Pentacene deposited onto PMMAmore » layer formed needled-like-shape grains with 10.26 nm surface roughness. These properties were related as thin film formed and its surface roughness plays important role towards good mobility devices.« less
NASA Astrophysics Data System (ADS)
Ibrahim, M. D.; Yunos, Y. S.; Rigit, A. R. H.; Mohtadzar, N. A. A.; Watanabe, N.; Sunami, Y.; Rahman, M. R. A.; Wong, L. K.; Mohtar, M. Z.
2017-04-01
This paper presents a titanium quadrupletip micro-needle integrated with a micro-pump with different inner designs, length and diameter of the micro-channels to measure and maximize the velocity flow in the micro-needle as blood delivered into human body. Titanium is used as the material of the micro-needle which are also the common material in manufacturing of micro-needle. The advancement of micro-needle technologies is improved in penetrating human outermost skin, stratum corneum and further to human blood vessels. The micro-needles with channel inner design of circular, square, hexagon, and dodecagon with quadruple tip designs are drawn with inner diameter parameter of 150μm and 100μm with two different channel length which are 10mm and 25mm. The characteristics of blood delivery in geometrically changed inner designs affect the output velocity in microneedle when the micropump is operating. The results showed that, when it is pumped at 0.04m/s, the blood velocity improved by 5.6% than when the pump is increased by 30% of its capacity. This is due to the backflow generated in the micropump.
DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR).
Paik, Ji-Sun; Kim, Su-Ah; Doh, Sang-Hee
2013-01-01
In this study, we introduce DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR), in which a guide needle helps in measuring the initial Jones tube length for insertion and reduces unnecessary handling for tube changes. Three CDCR procedures were conducted in which the length of the Jones tube was calculated using a 22-gauge DIY guide needle, and a prospective study of tube position change and migration, (a major cause of CDCR failure) was done. Wound healing was almost complete within 4 weeks postoperatively in the osteotomy site, but in cases of partial middle turbinectomy, a little more time was necessary. There was a slight change in Jones tube position in the nasal cavity compared with the expected position of original tube tip, but no tube migration from the caruncle fixation position had occurred by the final follow-up time. This guide-needle-assisted CDCR has multiple advantages, such as easy measurement of the proper initial tube size, utilization of the initial needle path, and easy replacement of tubes. Finally, this approach to CDCR can be readily applied because it uses materials ordinarily found in hospitals to create the devices needed for the procedure, so there is no additional cost.
Yamaguchi, Satoshi; Tsutsui, Kihei; Satake, Koji; Morikawa, Shigehiro; Shirai, Yoshiaki; Tanaka, Hiromi T
2014-10-01
Our goal was to develop a three-dimensional finite element model that enables dynamic analysis of needle insertion for soft materials. To demonstrate large deformation and fracture, we used the arbitrary Lagrangian-Eulerian (ALE) method for fluid analysis. We performed ALE-based finite element analysis for 3% agar gel and three types of copper needle with bevel tips. To evaluate simulation results, we compared the needle deflection and insertion force with corresponding experimental results acquired with a uniaxial manipulator. We studied the shear stress distribution of agar gel on various time scales. For 30°, 45°, and 60°, differences in deflections of each needle between both sets of results were 2.424, 2.981, and 3.737mm, respectively. For the insertion force, there was no significant difference for mismatching area error (p<0.05) between simulation and experimental results. Our results have the potential to be a stepping stone to develop pre-operative surgical planning to estimate an optimal needle insertion path for MR image-guided microwave coagulation therapy and for analyzing large deformation and fracture in biological tissues. Copyright © 2014 Elsevier Ltd. All rights reserved.
a Computational Approach to Explore Protein Translocation Through Type III Secretion Apparatus
NASA Astrophysics Data System (ADS)
Rathinavelan, Thenmalarchelvi; Im, Wonpil
2010-01-01
Many Gram-negative bacteria initiate infections by injecting effector proteins into host cells through the type III secretion apparatus (TTSA) that is comprised of a basal body, a needle, and a tip. The needle channel is formed by the assembly of a single needle protein. To explore the export mechanisms of MxiH needle protein through the needle of Shigella flexneri, an essential step during needle assembly, we have performed steered molecular dynamics simulations in implicit solvent. Interestingly, the electronegative channel interior creates an energy barrier for MxiH to enter the channel, while the same may facilitate the ejection of the effectors into host cells. Structurally-known basal regions and ATPase underneath the basal region have also such electronegative interior, while effector proteins have considerable electronegative patches on their surfaces. Based on these observations, we propose a repulsive electrostatic mechanism for protein translocation through the TTSA. This mechanism is supported by the suggestion that an ATPase is required for protein translocation through these nanomachines, which may provide the energy to overcome the initial electrostatic energy barrier. A similar mechanism may be applicable to macromolecular channels in other secretion systems or viruses through which proteins or nucleic acids are transported.
Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Caudrelier, Jean; Bauones, Salem; Tsoumakidou, Georgia; Koch, Guillaume; Gangi, Afshin
2017-09-01
To present a new blunt-tip coaxial needle (SoftGuard) applied to access "hard-to-reach" targets undergoing percutaneous image-guided biopsy or drainage. All consecutive patients presenting between August and December 2016 with "hard-to-reach" (<10 mm from a critical nearby structure such as vessels, nerves, bowel or adjacent parenchymal organs) solid lesions requiring biopsy (group A) or abscesses requiring drainage for sepsis (group B) were prospectively included. The individual features of each patient and lesion as well as technical and clinical data were collected and analysed. Twenty-six patients (18 males, 8 females, mean age 59.81 ± 17.53 years) were enrolled in group A and nine (6 males, 3 females, mean age 58.33 ± 13.8 years) in group B. Technical success was achieved in 92.3% of cases from group A and 100% of cases from group B. Five (19.2%) minor complications were noted in group A (four small self-limiting pneumothoraces and one small self-limiting peri-pancreatic haematoma). There were no complications in group B. Histological results in group A accounted for 95% sensitivity, 100% specificity and 95.2% diagnostic accuracy. In group B, mean post-operative C-reactive protein was 41 ± 48.3 mg/L in comparison with 155 ± 117.5 mg/L at baseline (P = 0.004). The SoftGuard blunt-tip needle is a safe and effective tool when applied as a coaxial working cannula for percutaneous biopsy or drainage of "hard-to-reach" targets.
[Theoretical origin and clinical application of wrist-ankle acupuncture therapy].
Wang, Qiong; Zhou, Qinghui
2017-05-12
The theory of wrist-ankle acupuncture is consistent with traditional meridian-collateral theory. For example, the body divisions of wrist-ankle acupuncture are corresponding to the distribution of 12 cutaneous regions of meridians, the needling sites of it are to the running courses of 12 meridians; the indications of it are to those of 12 meridians. The needling sites of wrist-ankle acupuncture are relevant with some special acupoints of acupuncture theory. For example, the 12-needling sites of wrist-ankle acupuncture are located similar to those of 12 meridian points and have very similar indications. The needling sites of it are located in the wrist and ankle regions, in which the five- shu points are located nearby, for meridian disorders. Most luo -connecting points are located near to the needling sites of wrist-ankle acupuncture or the needle tip points to. Additionally, the needling method of wrist-ankle acupuncture is consistent with some of the subcutaneous needling methods in traditional acupuncture therapy. On the basis of the aspects mentioned above, it is explained that wrist-ankle acupuncture is the development of traditional acupuncture and cannot be independent from the traditional theories of acupuncture and meridians. It is necessary to seek for the evidence from the traditional theories of TCM. The traditional theories of TCM are summarized from clinical practice, which can be newly verified from the practice of wrist-ankle acupuncture.
[Percutaneous needle aponeurotomy for Dupuytren's disease].
Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F
2016-02-01
Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.
Thermal comparison of Infiniti OZil and Signature Ellips phacoemulsification systems.
Schmutz, Joseph S; Olson, Randall J
2010-05-01
To determine thermal characteristics of Signature Ellips (Abbott Medical Optics) and Infiniti OZil (Alcon, Inc.) transverse ultrasound and compare both with longitudinal ultrasound in clinically relevant scenarios. Laboratory investigation. Temperature increase over baseline after 60 seconds was measured in water at positions in 90-degree increments around the sleeve near the proximal needle shaft in an artificial chamber for Ellips and OZil on continuous ultrasound with aspiration blocked and unblocked. This was also done with Signature using longitudinal ultrasound, with and without micropulse (6 ms on, 12 ms off), with aspiration blocked and unblocked, and at the OZil sleeve tip on continuous transverse mode with aspiration unblocked. OZil (8.1 +/- 0.3 C) had greater temperature increase than Ellips (5.2 +/- 0.3 C; P < .0001) with aspiration unblocked and blocked (29.3 +/- 1.0 C vs 12.2 +/- 0.7 C; P < .0001). OZil had uneven distribution of heat around the shaft (30.1 +/- 0.5 C vs 28.5 +/- 0.6 C; P < .0001), whereas Ellips did not (P = .57). OZil was cooler at the tip (6.6 +/- 0.2 C; P < .0001). Friction in a cadaver eye incision only increased these numbers by 10% (OZil, irrigation blocked). Metal stress probably creates heat at the proximal needle junction for both transverse methods. Heat generation differences between OZil and Ellips result from the manner in which they create needle motion. Incision burns may occur, especially for OZil, under nonpulsed settings during fragment removal with occlusion when reaching across the anterior chamber such that the proximal needle shaft came near the wound. Copyright 2010 Elsevier Inc. All rights reserved.
Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement.
Tacher, Vania; Petit, Arthur; Derbel, Haytham; Novelli, Luigi; Vitellius, Manuel; Ridouani, Fourat; Luciani, Alain; Rahmouni, Alain; Duvoux, Christophe; Salloum, Chady; Chiaradia, Mélanie; Kobeiter, Hicham
2017-11-01
To assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement. All consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated. Sixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm 2 , fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%). This study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.
Amperometric Carbon Fiber Nitrite Microsensor for In Situ Biofilm Monitoring
A highly selective needle type solid state amperometric nitrite microsensor based on direct nitrite oxidation on carbon fiber was developed using a simplified fabrication method. The microsensor’s tip diameter was approximately 7 µm, providing a high spatial resolution of at lea...
Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan
2017-04-01
Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.
Barta, Michael L.; Dickenson, Nicholas E.; Patil, Mrinalini; Keightley, Andrew; Wyckoff, Gerald J.; Picking, William D.; Picking, Wendy L.; Geisbrecht, Brian V.
2012-01-01
Many pathogenic Gram-negative bacteria utilize type III secretion systems (T3SS) to alter the normal functions of target cells. Shigella flexneri uses its T3SS to invade human intestinal cells to cause bacillary dysentery (shigellosis) which is responsible for over one million deaths per year. The Shigella type III secretion apparatus (T3SA) is comprised of a basal body spanning both bacterial membranes and an exposed oligomeric needle. Host altering effectors are secreted through this energized unidirectional conduit to promote bacterial invasion. The active needle tip complex of S. flexneri is composed of a tip protein, IpaD, and two pore-forming translocators, IpaB and IpaC. While the atomic structure of IpaD has been elucidated and studied, structural data on the hydrophobic translocators from the T3SS family remain elusive. We present here the crystal structures of a protease-stable fragment identified within the N-terminal regions of IpaB from S. flexneri and SipB from Salmonella enterica serovar Typhimurium determined at 2.1 Å and 2.8 Å limiting resolution, respectively. These newly identified domains are comprised of extended length (114 Å in IpaB and 71 Å in SipB) coiled-coil motifs that display a high degree of structural homology to one another despite the fact that they share only 21% sequence identity. Further structural comparisons also reveal substantial similarity to the coiled-coil regions of pore-forming proteins from other Gram-negative pathogens, notably colicin Ia. This suggests that these mechanistically-separate and functionally-distinct membrane-targeting proteins may have diverged from a common ancestor during the course of pathogen-specific evolutionary events. PMID:22321794
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barta, Michael L.; Dickenson, Nicholas E.; Patil, Mrinalini
2012-03-26
Many pathogenic Gram-negative bacteria utilize type III secretion systems (T3SSs) to alter the normal functions of target cells. Shigella flexneri uses its T3SS to invade human intestinal cells to cause bacillary dysentery (shigellosis) that is responsible for over one million deaths per year. The Shigella type III secretion apparatus is composed of a basal body spanning both bacterial membranes and an exposed oligomeric needle. Host altering effectors are secreted through this energized unidirectional conduit to promote bacterial invasion. The active needle tip complex of S. flexneri is composed of a tip protein, IpaD, and two pore-forming translocators, IpaB and IpaC.more » While the atomic structure of IpaD has been elucidated and studied, structural data on the hydrophobic translocators from the T3SS family remain elusive. We present here the crystal structures of a protease-stable fragment identified within the N-terminal regions of IpaB from S. flexneri and SipB from Salmonella enterica serovar Typhimurium determined at 2.1 {angstrom} and 2.8 {angstrom} limiting resolution, respectively. These newly identified domains are composed of extended-length (114 {angstrom} in IpaB and 71 {angstrom} in SipB) coiled-coil motifs that display a high degree of structural homology to one another despite the fact that they share only 21% sequence identity. Further structural comparisons also reveal substantial similarity to the coiled-coil regions of pore-forming proteins from other Gram-negative pathogens, notably, colicin Ia. This suggests that these mechanistically separate and functionally distinct membrane-targeting proteins may have diverged from a common ancestor during the course of pathogen-specific evolutionary events.« less
NASA Astrophysics Data System (ADS)
McAllister, Devin V.; Wang, Ping M.; Davis, Shawn P.; Park, Jung-Hwan; Canatella, Paul J.; Allen, Mark G.; Prausnitz, Mark R.
2003-11-01
Arrays of micrometer-scale needles could be used to deliver drugs, proteins, and particles across skin in a minimally invasive manner. We therefore developed microfabrication techniques for silicon, metal, and biodegradable polymer microneedle arrays having solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 μm. When solid microneedles were used, skin permeability was increased in vitro by orders of magnitude for macromolecules and particles up to 50 nm in radius. Intracellular delivery of molecules into viable cells was also achieved with high efficiency. Hollow microneedles permitted flow of microliter quantities into skin in vivo, including microinjection of insulin to reduce blood glucose levels in diabetic rats. transdermal drug delivery | skin | microelectromechanical systems | solid microneedle | hollow needle injection
Masai, Kyohei; Sasada, Shinji; Izumo, Takehiro; Taniyama, Tomoko; Nakamura, Yukiko; Chavez, Christine; Sakurai, Hiroyuki; Tsuta, Koji; Tsuchida, Takaaki
2013-10-01
Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.
[Needling technique of Professor Li Yan-Fang].
Li, Li-Jun
2014-01-01
Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the running course of meridians.
Snyder, Michael E; Lindsell, Luke B
2010-02-01
Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay
2018-01-01
The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.
Ganpule, Arvind P.; Deshmukh, Chaitanya S.; Joshi, Tanmay
2018-01-01
Introduction: The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a ”key” instrument to accomplish this arduous task. Instrument: The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. Validation: We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. Conclusion: The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder. PMID:28782740
Kanasashi, Tsutomu; Sugiura, Yuki; Takenaka, Chisato; Hijii, Naoki; Umemura, Mitsutoshi
2015-01-01
We assessed the radiocesium contamination of sugi (Cryptomeria japonica) forests in eastern Japan from November 2012 to February 2013, including 80 sites in Fukushima and 35 sites in other regions (Tohoku and Kanto-Koshinetsu), by measuring the (137)Cs concentrations in needles of different ages, male flowers, and pollen. Over a wide geographic area, needles that were present at the time of the Fukushima Dai-ichi Nuclear Power Plant accident contained much higher (137)Cs concentrations than needles that emerged after the accident. This result, together with visual analysis of (137)Cs distribution using autoradiography, indicated that some of the (137)Cs derived from direct fallout remained on the surface of the older needles. Since we also detected (137)Cs in younger needles and male flowers, we concluded that (137)Cs was translocated toward the tips of sugi needles. The (137)Cs concentration in male flowers was higher than and positively correlated with that in the currently growing (2012) needles. Also, a positive relationship was observed between the (137)Cs concentration of male flowers and pollen, and they were found to be nearly identical (137)Cs concentration. These results indicate the occurrence of acropetal translocation of (137)Cs from old needles to young needles, male flowers and pollen. However, the results as related to (137)Cs concentration in the needles of three different ages differed from the results of similar studies conducted more than 4 y after the Chernobyl accident. This suggests that, 2 y after the Fukushima Dai-ichi NPP accident, the distribution of (137)Cs in the sugi forests has not yet reached a steady state. Copyright © 2014 Elsevier Ltd. All rights reserved.
Radiofrequency Cauterization with Biopsy Introducer Needle
Pritchard, William F.; Wray-Cahen, Diane; Karanian, John W.; Hilbert, Stephen; Wood, Bradford J.
2014-01-01
PURPOSE The principal risks of needle biopsy are hemorrhage and implantation of tumor cells in the needle tract. This study compared hemorrhage after liver and kidney biopsy with and without radiofrequency (RF) ablation of the needle tract. MATERIALS AND METHODS Biopsies of liver and kidney were performed in swine through introducer needles modified to allow RF ablation with the distal 2 cm of the needle. After each biopsy, randomization determined whether the site was to undergo RF ablation during withdrawal of the introducer needle. Temperature was measured with a thermistor stylet near the needle tip, with a target temperature of 70°C–100°C with RF ablation. Blood loss was measured as grams of blood absorbed in gauze at the puncture site for 2 minutes after needle withdrawal. Selected specimens were cut for gross examination. RESULTS RF ablation reduced bleeding compared with absence of RF ablation in liver and kidney (P < .01), with mean blood loss reduced 63% and 97%, respectively. Mean amounts of blood loss (±SD) in the liver in the RF and no-RF groups were 2.03 g ± 4.03 (CI, 0.53–3.54 g) and 5.50 g ± 5.58 (CI, 3.33–7.66 g), respectively. Mean amounts of blood loss in the kidney in the RF and no-RF groups were 0.26 g ± 0.32 (CI, −0.01 to 0.53 g) and 8.79 g ± 7.72 (CI, 2.34–15.24 g), respectively. With RF ablation, thermal coagulation of the tissue surrounding the needle tract was observed. CONCLUSION RF ablation of needle biopsy tracts reduced hemorrhage after biopsy in the liver and kidney and may reduce complications of hemorrhage as well as implantation of tumor cells in the tract. PMID:14963187
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
NASA Astrophysics Data System (ADS)
Kwak, C.-M.; Seol, J.-B.; Kim, Y.-T.; Park, C.-G.
2017-02-01
For the past 10 years, laser-assisted atom probe tomography (APT) analysis has been performed to quantify the near-atomic scale distribution of elements and their local chemical compositions within interfaces that determine the design, processing, and properties of virtually all materials. However, the nature of the occurring laser-induced emission at the surface of needle-shaped sample is highly complex and it has been an ongoing challenge to understand the surface-related interactions between laser-sources and tips containing non-conductive oxides for a robust and reliable analysis of multiple-stacked devices. Here, we find that the APT analysis of four paired poly-Si/SiO2 (conductive/non-conductive) multiple stacks with each thickness of 10 nm is governed by experimentally monitoring three experimental conditions, such as laser-beam energies ranged from 30 to 200 nJ, analysis temperatures varying with 30-100 K, and the inclination of aligned interfaces within a given tip toward analysis direction. Varying with laser-energy and analysis temperature, a drastic compositional ratio of doubly charged Si ions to single charged Si ions within conductive poly-Si layers is modified, as compared with ones detected in the non-conductive layers. Severe distorted APT images of multiple stacks are also inevitable, especially at the conductive layers, and leading to a lowering of the successful analysis yields. This lower throughput has been overcome though changing the inclination of interfaces within a given tip to analysis direction (planar interfaces parallel to the tip axis), but significant deviations in chemical compositions of a conductive layer counted from those of tips containing planar interfaces perpendicular to the tip axis are unavoidable owing to the Si2, SiH2O, and Si2O ions detected, for the first time, within poly-Si layers.
Mayun, A A; Nggada, H A; Abdulazzez, J O; Musa, A B; Pindiga, U H; Khalil, M I
2013-06-01
The study seeks to determine the advantages of using the pistol-grip syringe holder in the performance of FNAB over the use of direct finger grip method. The skin is cleaned with gauze soaked in methylated spirit and the lump is located and firmly held between the thumb and fore finger of the free hand. The syringe is held by the out side of the barrel or by pistol-grip, and the needle tip pushed into the lesion. The plunger is partially retracted, creating a negative pressure. The cutting edge of the needle tip frees the cells inside the lesion which are sucked into the fine bore of the needle. The contents of the needle are then emptied on a microscopic slide and thinly smeared. The slides are then fixed in alcohol and later stained. These were examined under the microscope and a comparison between the aspirations using pistol-grip and direct finger grip was made. A total of 266 cases of FNABs were carried out from 1st January to 31st December, 2008. There were 89 breast cases out of which 42 (47%) had pistol-grip method and 47 (53%) had direct finger grip method; 74 thyroid cases out of which 28 (38%) were pistol-grip and 46 (62%) were direct finger grip cases; 56 cases of lymph node FNABs of which 18(32%) and 38 (68%) had pistol-grip and direct finger grip methods respectively. There were 23 cases of salivary gland FNABs having 8 (35%) and 15 (65%) as pistol-grip and direct finger grip methods respectively. Marked cellularity was observed in the majority of cases using both methods of FNABs. This study has shown that the use of pistol-grip syringe holder in the performance of FNABs has no significant advantage compared to the direct finger grip method.
Beigi, Parmida; Rohling, Robert; Salcudean, Septimiu E; Ng, Gary C
2017-11-01
This paper presents a new micro-motion-based approach to track a needle in ultrasound images captured by a handheld transducer. We propose a novel learning-based framework to track a handheld needle by detecting microscale variations of motion dynamics over time. The current state of the art on using motion analysis for needle detection uses absolute motion and hence work well only when the transducer is static. We have introduced and evaluated novel spatiotemporal and spectral features, obtained from the phase image, in a self-supervised tracking framework to improve the detection accuracy in the subsequent frames using incremental training. Our proposed tracking method involves volumetric feature selection and differential flow analysis to incorporate the neighboring pixels and mitigate the effects of the subtle tremor motion of a handheld transducer. To evaluate the detection accuracy, the method is tested on porcine tissue in-vivo, during the needle insertion in the biceps femoris muscle. Experimental results show the mean, standard deviation and root-mean-square errors of [Formula: see text], [Formula: see text] and [Formula: see text] in the insertion angle, and 0.82, 1.21, 1.47 mm, in the needle tip, respectively. Compared to the appearance-based detection approaches, the proposed method is especially suitable for needles with ultrasonic characteristics that are imperceptible in the static image and to the naked eye.
Finite element analyses of a dual actuated prototype of a smart needle
NASA Astrophysics Data System (ADS)
Konh, Bardia; Podder, Tarun K.
2017-04-01
Brachytherapy is one of the most effective modalities for treating early stage prostate cancer. In this procedure, radioactive seeds are being placed in the prostate to kill the tumorous cells. Inaccurate placement of seeds can underdose the tumor and dangerously overdose the critical structures (urethra, rectum, bladder) and adjacent healthy tissues. It is very difficult, if not impossible, for the surgeons to compensate the needle misplacement errors while using the conventional passive straight needles. The smart needles actuated by shape memory alloy (SMA) wires are being developed to provide more actuation and control for the surgeons to achieve more geometric conformity. In our recent work, a prototype of a smart needle was developed where not only the actuation of SMA wires were incorporated, but also shape memory polymers (SMPs) were included in the design introducing a soft joint element to further assist the flexibility of the active surgical needles. The additional actuation of shape memory polymers provided the capability of reaching much high flexibility that was not achievable before. However, there are some disadvantages using this active SMP component compared to a passive Nylon joint component that are discussed in this work. The utilization of a heated SMP as a soft joint showed about 20% improvement in the final needle tip deflection. This work presents the finite element studies of the developed prototype. A finite element model that could accurately predict the behavior of the smart needle could be very valuable in analyzing and optimizing the future novel designs.
Technique for CT Fluoroscopy-Guided Lumbar Medial Branch Blocks and Radiofrequency Ablation.
Amrhein, Timothy J; Joshi, Anand B; Kranz, Peter G
2016-09-01
The purpose of this study is to describe the procedure for CT fluoroscopy-guided lumbar medial branch blocks and facet radiofrequency ablation. CT fluoroscopic guidance allows more-precise needle tip positioning and is an alternative method for performing medial branch blocks and facet radiofrequency ablation.
Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.
Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A
2010-02-01
Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.
A Repulsive Electrostatic Mechanism for Protein Export through the Type III Secretion Apparatus
Rathinavelan, Thenmalarchelvi; Zhang, Lingling; Picking, Wendy L.; Weis, David D.; De Guzman, Roberto N.; Im, Wonpil
2010-01-01
Abstract Many Gram-negative bacteria initiate infections by injecting effector proteins into host cells through the type III secretion apparatus, which is comprised of a basal body, a needle, and a tip. The needle channel is formed by the assembly of a single needle protein. To explore the export mechanisms of MxiH needle protein through the needle of Shigella flexneri, an essential step during needle assembly, we have performed steered molecular dynamics simulations in implicit solvent. The trajectories reveal a screwlike rotation motion during the export of nativelike helix-turn-helix conformations. Interestingly, the channel interior with excessive electronegative potential creates an energy barrier for MxiH to enter the channel, whereas the same may facilitate the ejection of the effectors into host cells. Structurally known basal regions and ATPase underneath the basal region also have electronegative interiors. Effector proteins also have considerable electronegative potential patches on their surfaces. From these observations, we propose a repulsive electrostatic mechanism for protein translocation through the type III secretion apparatus. Based on this mechanism, the ATPase activity and/or proton motive force could be used to energize the protein translocation through these nanomachines. A similar mechanism may be applicable to macromolecular channels in other secretion systems or viruses through which proteins or nucleic acids are transported. PMID:20141759
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu
Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less
Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W
2013-01-01
The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beleggia, M.; Helmholtz-Zentrum Berlin für Materialien und Energie, Berlin; Kasama, T.
We apply off-axis electron holography and Lorentz microscopy in the transmission electron microscope to map the electric field generated by a sharp biased metallic tip. A combination of experimental data and modelling provides quantitative information about the potential and the field around the tip. Close to the tip apex, we measure a maximum field intensity of 82 MV/m, corresponding to a field k factor of 2.5, in excellent agreement with theory. In order to verify the validity of the measurements, we use the inferred charge density distribution in the tip region to generate simulated phase maps and Fresnel (out-of-focus) imagesmore » for comparison with experimental measurements. While the overall agreement is excellent, the simulations also highlight the presence of an unexpected astigmatic contribution to the intensity in a highly defocused Fresnel image, which is thought to result from the geometry of the applied field.« less
Comparison of design features and mechanical properties of commercially available Veress needles.
Schramel, Johannes P; Kindslehner, Angelika; Bockstahler, Barbara A; Dupré, Gilles P
2017-10-01
To compare design features and mechanical properties of 13 commercially available Veress needles (VN). In vitro biomechanical study. Veress needles from 9 manufacturers (6 reusable, 6 disposable, and 1 with a reusable stylet combined with a disposable cannula) were included in the study. Veress needles are designed with a spring-loaded stylet to protect the tip of the cannula following insertion into the abdomen. Stylet forces were measured with a scale in a test jig by moving the stylet in 0.5 mm steps into the hollow cannula. Forces and spring rates were derived from force-displacement plots. Mass, mechanical dimensions, and the bevel angle and geometry were assessed. Differences between VN models were analyzed with a univariate analysis of variance. Results are reported as mean ± SD or median (range). Physical and mechanical parameters differed between models. The exposed stylet length was 3.5 mm (2-7). Three bevel geometries (bias, lancet type, and back-cut) with angles between 20° and 40° were identified. Reusable VN weigh more (24.9 ± 2.2 g) than disposable designs (6.0 ± 2.3 g). The mean values for the spring rate and the residual stylet force were 0.23 ± 0.08 Nmm -1 and 0.94 ± 0.28 N, respectively. The mean force required to move the stylet to the cannula tip was 1.81 ± 0.29 N and 2.77 ± 0.54 N to move to the proximal end of the bevel. Commercially available VN use diverse bevel geometries and have different mechanical characteristics. Studies investigating laparoscopic entry complications should explicitly report the type of VN model used. © 2017 The American College of Veterinary Surgeons.
Structure of the bacteriophage T4 long tail fiber receptor-binding tip
Bartual, Sergio G.; Otero, José M.; Garcia-Doval, Carmela; Llamas-Saiz, Antonio L.; Kahn, Richard; Fox, Gavin C.; van Raaij, Mark J.
2010-01-01
Bacteriophages are the most numerous organisms in the biosphere. In spite of their biological significance and the spectrum of potential applications, little high-resolution structural detail is available on their receptor-binding fibers. Here we present the crystal structure of the receptor-binding tip of the bacteriophage T4 long tail fiber, which is highly homologous to the tip of the bacteriophage lambda side tail fibers. This structure reveals an unusual elongated six-stranded antiparallel beta-strand needle domain containing seven iron ions coordinated by histidine residues arranged colinearly along the core of the biological unit. At the end of the tip, the three chains intertwine forming a broader head domain, which contains the putative receptor interaction site. The structure reveals a previously unknown beta-structured fibrous fold, provides insights into the remarkable stability of the fiber, and suggests a framework for mutations to expand or modulate receptor-binding specificity. PMID:21041684
Fevre, Marie-Cécile; Vincent, Caroline; Picard, Julien; Vighetti, Arnaud; Chapuis, Claire; Detavernier, Maxime; Allenet, Benoît; Payen, Jean-François; Bosson, Jean-Luc; Albaladejo, Pierre
2018-02-01
Ultrasound (US) guided needle positioning is safer than anatomical landmark techniques for central venous access. Hand-eye coordination and execution time depend on the professional's ability, previous training and personal skills. Needle guidance positioning systems (GPS) may theoretically reduce execution time and facilitate needle positioning in specific targets, thus improving patient comfort and safety. Three groups of healthcare professionals (41 anaesthesiologists and intensivists, 41 residents in anaesthesiology and intensive care, 39 nurse anaesthetists) were included and required to perform 3 tasks (positioning the tip of a needle in three different targets in a silicon phantom) by using successively a conventional US-guided needle positioning and a needle GPS. We measured execution times to perform the tasks, hand-eye coordination and the number of repositioning occurrences or errors in handling the needle or the probe. Without the GPS system, we observed a significant inter-individual difference for execution time (P<0.05), hand-eye coordination and the number of errors/needle repositioning between physicians, residents and nurse anaesthetists. US training and video gaming were found to be independent factors associated with a shorter execution time. Use of GPS attenuated the inter-individual and group variability. We observed a reduced execution time and improved hand-eye coordination in all groups as compared to US without GPS. Neither US training, video gaming nor demographic personal or professional factors were found to be significantly associated with reduced execution time when GPS was used. US associated with GPS systems may improve safety and decrease execution time by reducing inter-individual variability between professionals for needle-handling procedures. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Use of standard hypodermic needles for accessing laparoscopic adjustable gastric band ports.
Bewsher, Samuel Mark; Azzi, Anthony; Wright, Timothy
2010-06-01
Laparoscopic adjustable gastric banding is a common and successful method of surgically treating morbid obesity. A recipient will have to attend their surgeon's rooms a number of times to optimally adjust the amount of fluid in the band and hence the amount of restriction. Manufacturers suggest that the ports should be accessed with special non-coring needles that may not always be available in regional or remote centers, and this could create a safety risk in cases where urgent band deflation is required. Ports of two different brands were repeatedly accessed over 100 times in the same location while containing fluid under pressure, using a standard beveled 21 g hypodermic needle (SN) and a 20 g Huber tipped non-coring needle (NCN). The path the needles types took through the port septum was also examined. There was no leakage of fluid from any of the ports tested. Neither SN nor NCN passed through the port septum down their axis, but rather in a direction closer to that of their beveled surface. There is no more risk of "coring" the septum with a SN than with a NCN. SN can be used safely and routinely to access laparoscopic adjustable gastric band ports.
Arias, Sixto; Lee, Hans; Semaan, Roy; Frimpong, Bernice; Ortiz, Ricardo; Feller-Kopman, David; Oakjones-Burgess, Karen; Yarmus, Lonny
2015-05-23
Lung nodule evaluation represents a clinical challenge especially in patients with intermediate risk for malignancy. Multiple technologies are presently available to sample nodules for pathological diagnosis. Those technologies can be divided into bronchoscopic and non-bronchoscopic interventions. Electromagnetic navigational bronchoscopy is being extensively used for the endobronchial approach to peripheral lung nodules but has been hindered by anatomic challenges resulting in a 70% diagnostic yield. Electromagnetic navigational guided transthoracic needle lung biopsy is novel non-bronchoscopic method that uses a percutaneous electromagnetic tip tracked needle to obtain core biopsy specimens. Electromagnetic navigational transthoracic needle aspiration complements bronchoscopic techniques potentially allowing the provider to maximize the diagnostic yield during one single procedure. This article describes a novel integrated diagnostic approach to pulmonary lung nodules. We propose the use of endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging; radial EBUS, navigational bronchoscopy and E-TTNA during one single procedure to maximize diagnostic yield and minimize the number of invasive procedures needed to obtain a diagnosis. This manuscript describes in detail how the navigation transthoracic procedure is performed. Additional clinical studies are needed to determine the clinical utility of this novel technology.
Solute transport by flow yields geometric shocks in shape evolution
NASA Astrophysics Data System (ADS)
Huang, Jinzi (Mac); Davies Wykes, Megan; Hajjar, George; Ristroph, Leif; Shelley, Michael
2017-11-01
Geological processes such as erosion and dissolution of surfaces often lead to striking shapes with strikingly sharp features. We present observations of such features forming in dissolution under gravity. In our experiment, a dissolving body with initially smooth surface evolves into an increasingly sharp needle shape. A mathematical model of its shape dynamics, derived from a boundary layer theory, predicts that a geometric shock forms at the tip of dissolved body, with the tip curvature becoming infinite in finite time. We further discuss the model's application to similar processes, such as flow driven erosion which can yield corners.
Tan, Mark Zheng Yi; Brunswicker, Annemarie; Abdelraheem, Shamsaldeen; Sheehan, Alison
2017-04-01
Foreign bodies in the heart are rare occurrences with a limited evidence base to guide recommendations on management. We report a case of multiple cardioembolic strokes as a result of a self-inflicted sewing needle puncture from the anterior chest through the right ventricle and interventricular septum with its tip in the left ventricle close to the subvalvular apparatus in a 39-year-old psychiatric patient. We discuss issues surrounding decision making and ongoing care and highlight the importance of further follow-up and reporting of cases to form a robust evidence base to guide future recommendations. © 2017, Wiley Periodicals, Inc.
Porhomayon, Jahan; Zadeii, Gino; Yarahamadi, Alireza; Nader, Nader D.
2013-01-01
The developments of new spinal needles and needle tip designs have reduced the incidence of postdural puncture headache (PDPH). Although it is clear that reducing the loss of CSF leak from dural puncture reduces the headache, there are areas regarding the pathogenesis, treatment, and prevention of PDPH that remain controversial. Air travel by itself may impose physiological alteration in central nervous system that may be detrimental to patients with PDPH. This case report highlights a case of a young female patient who suffered from a severe incapacitating PDPH headache during high-altitude flight with a commercial jet. PMID:23401803
Uppal, Vishal; Sondekoppam, Rakesh V; Ganapathy, Sugantha
2014-10-01
During peripheral nerve block procedures, needle visibility decreases as the angle of needle insertion relative to skin increases due to loss of reflective signals. The primary aim of our study was to compare the effect of beam steering on the visibility of echogenic and non-echogenic block needles. PAJUNK non-echogenic and echogenic needles were inserted into pork meat at 20°, 40°, 60°, and 70° angles, and electronic beam steering was applied at three different angles (shallow, medium, and steep) to obtain the best possible needle images. Eleven anesthesiologists blinded to the type of needle or use of beam steering scored the images obtained (0 = needle not visible; 10 = excellent needle shaft and tip visibility). Mean scores were used to classify the needles as poor visibility (mean score 0-3.3), intermediate visibility (mean score 3.4-6.6), or good visibility (mean score 6.7-10). At 20°, the visibility scores were intermediate to good in all groups. At 40°, the mean (SD) visibility score for the non-echogenic needle improved significantly from 3.1 (1.4) to 7.9 (1.8) with application of beam steering (difference = 4.8; 95% confidence interval [CI]: 3.1 to 6.6; P < 0.001). At 60°, the mean (SD) visibility score for the non-echogenic needle was poor 0.6 (0.7) and remained poor 2.4 (1.1) with beam steering. One the other hand, the echogenic needle without beam steering 6.5 (1.8) scored significantly better than the non-echogenic needle with beam steering 2.4 (1.1) (difference = 4.2; 95% CI: 2.7 to 5.6; P < 0.001). At 70°, the mean needle visibility score was poor for the non-echogenic needle with or without beam steering. In contrast, the echogenic needle attained an intermediate visibility score with or without beam steering. Beam steering did not significantly change the visibility scores of either the echogenic or the non-echogenic needle (P = 0.088 and 0.056, respectively) at a 70° angle. The PAJUNK echogenic needle, with or without beam steering, was more visible when compared with the non-echogenic needle at 60° and 70° angles of insertion. In contrast, at a 40° angle of needle insertion, the non-echogenic needle with beam steering was more visible compared with the echogenic needle.
Giannakopoulos, Stilianos; Bantis, Athanasios; Kalaitzis, Christos; Touloupidis, Stavros
2010-10-01
Occasionally during percutaneous surgery, significant contrast extravasation obscures the field, making fluoroscopic access no longer feasible. Herein, we describe a salvage technique. The cystoscopically placed, open-end ureteral catheter is exchanged with an angled-tip angiographic catheter. With the aid of a guidewire and under fluoroscopic guidance, the tip of the catheter is placed in a posterior calix. The "bull's eye" technique is then applied to direct the needle into the tip of the catheter. This technique was used in four cases over a 7-year period. Successful access was accomplished in all cases through a middle or upper calix. The catheter serves as a target for providing access to the renal collecting system and facilitates final tract dilatation.
Anderson, T. Anthony; Kang, Jeon Woong; Gubin, Tatyana; Dasari, Ramachandra R.; So, Peter T. C.
2016-01-01
BACKGROUND Neuraxial anesthesia and epidural steroid injection techniques require precise anatomical targeting to ensure successful and safe analgesia. Previous studies suggest that only some of the tissues encountered during these procedures can be identified by spectroscopic methods, and no previous study has investigated the use of Raman, diffuse reflectance, and fluorescence spectroscopies. The authors hypothesized that real-time needle-tip spectroscopy may aid epidural needle placement and tested the ability of spectroscopy to distinguish each of the tissues in the path of neuraxial needles. METHODS For comparison of detection methods, the spectra of individual, dissected ex vivo paravertebral and neuraxial porcine tissues were collected using Raman spectroscopy (RS), diffuse reflectance spectroscopy (DRS), and fluorescence spectroscopy (FS). Real-time spectral guidance was tested using a 2 mm inner diameter fiber optic probe-in-needle device. Raman spectra were collected during the needle’s passage through intact paravertebral and neuraxial porcine tissue and analyzed afterward. The RS tissue signatures were verified as mapping to individual tissue layers using histochemical staining and widefield microscopy. RESULTS Raman spectroscopy revealed a unique spectrum for all ex vivo paravertebral and neuraxial tissue layers; DRS and FS spectra were not distinct for all tissues. Moreover, when accounting for the expected order of tissues, real-time Raman spectra recorded during needle insertion also permitted identification of each paravertebral and neuraxial porcine tissue. CONCLUSIONS This study demonstrates Raman spectroscopy can distinguish the tissues encountered during epidural needle insertion. This technology may prove useful during needle placement by providing evidence of its anatomical localization. PMID:27466032
Robust path planning for flexible needle insertion using Markov decision processes.
Tan, Xiaoyu; Yu, Pengqian; Lim, Kah-Bin; Chui, Chee-Kong
2018-05-11
Flexible needle has the potential to accurately navigate to a treatment region in the least invasive manner. We propose a new planning method using Markov decision processes (MDPs) for flexible needle navigation that can perform robust path planning and steering under the circumstance of complex tissue-needle interactions. This method enhances the robustness of flexible needle steering from three different perspectives. First, the method considers the problem caused by soft tissue deformation. The method then resolves the common needle penetration failure caused by patterns of targets, while the last solution addresses the uncertainty issues in flexible needle motion due to complex and unpredictable tissue-needle interaction. Computer simulation and phantom experimental results show that the proposed method can perform robust planning and generate a secure control policy for flexible needle steering. Compared with a traditional method using MDPs, the proposed method achieves higher accuracy and probability of success in avoiding obstacles under complicated and uncertain tissue-needle interactions. Future work will involve experiment with biological tissue in vivo. The proposed robust path planning method can securely steer flexible needle within soft phantom tissues and achieve high adaptability in computer simulation.
Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.
van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina
2017-12-13
Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com
Laparoscopic access with a visualizing trocar.
Wolf, J S
1997-01-01
Although useful in most situations, there are several inherent disadvantages of the standard laparoscopic access techniques of Veress needle insertion and Hasson-type cannula placement. Veress needle placement may be hazardous in patients at high risk for intraabdominal adhesions and difficult in patients who are obese. The usual alternative, the Hasson-type cannula, often does not provide a good gas seal. As another option, the use of a visualizing trocar (OPTIVIEW) has proven to be effective in the initial experience at the University of Michigan. The inner trocar of the visualizing trocar is hollow except for a clear plastic conical tip with two external ridges. The trocar-cannula assembly is passed through tissue layers to enter the operative space under direct vision from a 10-mm zero-degree laparoscope placed into the trocar. Results suggest that this technique is an excellent alternative to Veress needle placement when laparoscopic access is likely to be hazardous or difficult.
Bucher, S; Hornung, J; Bonkowsky, V; Iro, H; Zenk, J
2010-04-01
High frequency thermotherapy (HFTT) is an established palliative therapy for hepatic malignancies. An in vivo and in vitro trial examined the preconditions for the application of HFTT with liquid-cooled wet electrodes for minimally invasive palliation of head and neck tumors. HFTT was applied with needle electrodes, cooled with isotonic saline solution, and a high-frequency generator (Elektrotom HiTT 106, Berchtold, Tuttlingen) to porcine tongue and narcotized, juvenile domestic pigs to the tongue and neck, and monitored in realtime by B-mode ultrasound. The direction of spread of the hyperthermic zone is well observed using ultrasound. Determining the direction of spread is not possible with cooled-tip electrode needles. Severe complications were not observed during the application. RFA with liquid-cooled needle applicators is not safely applicable for the therapy of head and neck tumors.
Production of atmospheric-pressure glow discharge in nitrogen using needle-array electrode
NASA Astrophysics Data System (ADS)
Takaki, K.; Hosokawa, M.; Sasaki, T.; Mukaigawa, S.; Fujiwara, T.
2005-04-01
An atmospheric pressure glow discharge was generated using a needle-array electrode in nitrogen, and the voltage-current characteristics of the glow discharge were obtained in a range from 1 mA to 60 A. A pulsed high voltage with short rise time under 10 ns was employed to generate streamer discharges simultaneously at all needle tips. The large number of streamer discharges prevented the glow-to-arc transition caused by inhomogeneous thermalization. Semiconductor opening switch diodes were employed as an opening switch to shorten the rise time. The glow voltage was almost constant until the discharge current became 0.3 A, whereas the voltage increased with the current higher than 0.3 A. Electron density and temperature in a positive column of the glow discharge at 60 A were obtained to 1.4×1012cm-3 and 1.3 eV from calculation based on nitrogen swarm data.
Hatfield, Malcolm K; Handrich, Stephen J; Willis, Jeffrey A; Beres, Robert A; Zaleski, George X
2008-06-01
The objective of our study was to compare the incidence of blood patch as the best objective indicator of postdural puncture headache after elective fluoroscopic lumbar puncture with the use of a 22-gauge Whitacre (pencil point) needle versus standard 22- and 20-gauge Quincke (bevel-tip) needles and to determine the best level of puncture. The records of 724 consecutive patients who were referred to St. Mary's Medical Center department of radiology for fluoroscopic lumbar puncture from January 2003 through April 2007 were retrospectively reviewed. Emergency requests (191) were discarded along with those for patients with clinical signs of pseudotumor cerebri (21), normal pressure hydrocephalus (3), and failed attempts (4). The collective total was 505 elective lumbar punctures. The blood patch rate for the 22-gauge Whitacre needle was 4.2%. The result for the 22-gauge Quincke point needle was 15.1% whereas that for the 20-gauge Quincke point needle was 29.6%. In addition, the level of puncture showed a blood patch rate that increased as the level of lumbar puncture lowered. The highest level of lumbar puncture was L1-L2 with the lowest recorded level being L5-S1. The Whitacre needle is associated with a significantly lower incidence of blood patch rate after lumbar puncture. The highest level of puncture (L1-L2) also provides the lowest level of blood patch rate.
The ACUSITT ultrasonic ablator: the first steerable needle with an integrated interventional tool
NASA Astrophysics Data System (ADS)
Burdette, E. Clif; Rucker, D. Caleb; Prakash, Punit; Diederich, Chris J.; Croom, Jordon M.; Clarke, Clyde; Stolka, Philipp; Juang, Titania; Boctor, Emad M.; Webster, Robert J., III
2010-03-01
Steerability in percutaneous medical devices is highly desirable, enabling a needle or needle-like instrument to avoid sensitive structures (e.g. nerves or blood vessels), access obstructed anatomical targets, and compensate for the inevitable errors induced by registration accuracy thresholds and tissue deformation during insertion. Thus, mechanisms for needle steering have been of great interest in the engineering community in the past few years, and several have been proposed. While many interventional applications have been hypothesized for steerable needles (essentially anything deliverable via a regular needle), none have yet been demonstrated as far as the authors are aware. Instead, prior studies have focused on model validation, control, and accuracy assessment. In this paper, we present the first integrated steerable needle-interventional device. The ACUSITT integrates a multi-tube steerable Active Cannula (AC) with an Ultrasonic Interstitial Thermal Therapy ablator (USITT) to create a steerable percutaneous device that can deliver a spatially and temporally controllable (both mechanically and electronically) thermal dose profile. We present our initial experiments toward applying the ACUSITT to treat large liver tumors through a single entry point. This involves repositioning the ablator tip to several different locations, without withdrawing it from the liver capsule, under 3D Ultrasound image guidance. In our experiments, the ACUSITT was deployed to three positions, each 2cm apart in a conical pattern to demonstrate the feasibility of ablating large liver tumors 7cm in diameter without multiple parenchyma punctures.
2014-01-01
Background Root canal irrigation carries a risk of extrusion of irrigant into the periapical tissues which can be associated with pain, swelling, and tissue damage. Studies have shown less extrusion with sonic or apical negative pressure devices compared with syringe and side-port needle or passive ultrasonic irrigation with continuous irrigant flow. This study aimed to evaluate the effectiveness of the EndoVac irrigation system, regarding 1) debris removal and 2) the control of apically extruded irrigating solution. Methods Fifty extracted human single-rooted teeth were used in this study. The teeth were then randomly divided into three experimental groups according to the type of irrigation used and one control group. In group 1, irrigation was performed using the EndoVac irrigation system. In group 2, irrigation was performed using a 30-gauge, tip-vented irrigation needle. In group 3, irrigation was performed using a 30-gauge, side-vented irrigation needle. The control group received instrumentation with no irrigation to serve as a control for cleaning efficiency. Root canal instrumentation was performed using the Profile NiTi rotary system with a crown-down technique. All of the experimental teeth were irrigated with the same amount of 5.25% sodium hypochlorite. The amount of extruded irrigating solution was then measured by subtracting the post-instrumentation weight from the pre-instrumentation weight using an electronic balance. The cleanliness of debris removal was evaluated using scanning electron microscopy. Results EndoVac irrigation had the least amount of extrusion followed by the side-vented and tip-vented method. The difference between the groups was statistically significant (P <0.01). As for the cleaning results, the debris collection in the EndoVac and tip-vented groups was the least in the apical third. In the control and the side-vented groups, the debris was the greatest in the apical third, but this difference was not significant among the three experimental groups. Conclusions The EndoVac irrigation system extruded significantly less irrigant solution than either needle irrigation system. Debris collection was the least in the apical third for the EndoVac irrigation system. No significant difference was found in the cleaning efficiency among the three irrigation systems. PMID:24512441
Spanos, Stephanie; Booth, Rebekah; Koenig, Heidi; Sikes, Kendra; Gracely, Edward; Kim, In K
2008-08-01
Peripheral intravenous (PIV) catheter insertion is a frequent, painful procedure that is often performed with little or no anesthesia. Current approaches that minimize pain for PIV catheter insertion have several limitations: significant delay for onset of anesthesia, inadequate anesthesia, infectious disease exposure risk from needlestick injuries, and patients' needle phobia. Comparison of the anesthetic effectiveness of J-Tip needle-free jet injection of 1% buffered lidocaine to the anesthetic effectiveness of topical 4% ELA-Max for PIV catheter insertion. A prospective, block-randomized, controlled trial comparing J-Tip jet injection of 1% buffered lidocaine to a 30-minute application of 4% ELA-Max for topical anesthesia in children 8 to 15 years old presenting to a tertiary care pediatric emergency department for PIV catheter insertion. All subjects recorded self-reported visual analog scale (VAS) scores for pain at time of enrollment and pain felt following PIV catheter insertion. Jet injection subjects also recorded pain of jet injection. Subjects were videotaped during jet injection and PIV catheter insertion. Videotapes were reviewed by a single blinded reviewer for observer-reported VAS pain scores for jet injection and PIV catheter insertion. Of the 70 children enrolled, 35 were randomized to the J-Tip jet injection group and 35 to the ELA-Max group. Patient-recorded enrollment VAS scores for pain were similar between groups (P = 0.74). Patient-recorded VAS scores were significantly different between groups immediately after PIV catheter insertion (17.3 for J-Tip jet injection vs 44.6 for ELA-Max, P < 0.001). Blinded reviewer assessed VAS scores for pain after PIV catheter insertion demonstrated a similar trend, but the comparison was not statistically significant (21.7 for J-Tip jet injection vs 31.9 ELA-Max, P = 0.23). J-Tip jet injection of 1% buffered lidocaine provided greater anesthesia than a 30-minute application of ELA-Max according to patient self-assessment of pain for children aged 8 to 15 years undergoing PIV catheter insertion.
Hochstrasser, Raphael J; Endler, P Christian; Klein, Sabine D
2015-08-01
So far, most research attempts to explain the mechanism of the action of acupuncture have focused mostly on mechanically-triggered active factors and have produced inconclusive findings. In this study, we investigate whether acupuncture might also involve nonmechanical, nonpsychological active factors originating in the therapist. In 30 individuals, an acupuncture needle was inserted in the acupoint PC6 using a special device without touching the needle. A second device was used to fix the needle rigidly in place, excluding any mechanical transmission of movement from the handle to the needle's tip. Each participant was exposed in random order to a control and a stimulation phase. During the stimulation phase, the free needle's end was held by the therapist to allow the transmission of Qi; during the control phase, it was left untouched. Participants' subjective sensations during the stimulation phase and the control phase were recorded using a questionnaire. Twenty-two of 28 (79%; p = 0.003) test participants believed that they had received stimulation when it had actually been performed, and 26 (93%; p < 0.001) sensed differences between the two experimental phases. Thus, participants were able to sense the transmission of therapeutic Qi in the absence of mechanical or psychological factors. Copyright © 2015. Published by Elsevier B.V.
Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use
2016-06-01
Lamb shank, which has complexity of tendon, fascia, and bone, was used to mimic human tissue. The needles (n=10) were stressed in the tissue substitute...needles were re-imaged after stressing and visually assessed. RESULTS: Only one manufacturing scuff mark was noted out of 90 needles before stress ...testing. Needles buckled but did not break when they were stressed beyond normal clinical use. No cracks or fractures were noted after stress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus
PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement ofmore » the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.« less
Dickenson, Nicholas E; Choudhari, Shyamal P; Adam, Philip R; Kramer, Ryan M; Joshi, Sangeeta B; Middaugh, C Russell; Picking, Wendy L; Picking, William D
2013-01-01
The Shigella flexneri Type III secretion system (T3SS) senses contact with human intestinal cells and injects effector proteins that promote pathogen entry as the first step in causing life threatening bacillary dysentery (shigellosis). The Shigella Type III secretion apparatus (T3SA) consists of an anchoring basal body, an exposed needle, and a temporally assembled tip complex. Exposure to environmental small molecules recruits IpaB, the first hydrophobic translocator protein, to the maturing tip complex. IpaB then senses contact with a host cell membrane, forming the translocon pore through which effectors are delivered to the host cytoplasm. Within the bacterium, IpaB exists as a heterodimer with its chaperone IpgC; however, IpaB's structural state following secretion is unknown due to difficulties isolating stable protein. We have overcome this by coexpressing the IpaB/IpgC heterodimer and isolating IpaB by incubating the complex in mild detergents. Interestingly, preparation of IpaB with n-octyl-oligo-oxyethylene (OPOE) results in the assembly of discrete oligomers while purification in N,N-dimethyldodecylamine N-oxide (LDAO) maintains IpaB as a monomer. In this study, we demonstrate that IpaB tetramers penetrate phospholipid membranes to allow a size-dependent release of small molecules, suggesting the formation of discrete pores. Monomeric IpaB also interacts with liposomes but fails to disrupt them. From these and additional findings, we propose that IpaB can exist as a tetramer having inherent flexibility, which allows it to cooperatively interact with and insert into host cell membranes. This event may then lay the foundation for formation of the Shigella T3SS translocon pore. PMID:23456854
Tsauo, Jiaywei; Luo, Xuefeng; Ye, Linchao; Li, Xiao
2015-06-01
This study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS). 3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate the angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients. Failure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures. Adjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.
Regulation of the Yersinia type III secretion system: traffic control
Dewoody, Rebecca S.; Merritt, Peter M.; Marketon, Melanie M.
2013-01-01
Yersinia species, as well as many other Gram-negative pathogens, use a type III secretion system (T3SS) to translocate effector proteins from the bacterial cytoplasm to the host cytosol. This T3SS resembles a molecular syringe, with a needle-like shaft connected to a basal body structure, which spans the inner and outer bacterial membranes. The basal body of the injectisome shares a high degree of homology with the bacterial flagellum. Extending from the T3SS basal body is the needle, which is a polymer of a single protein, YscF. The distal end of the needle serves as a platform for the assembly of a tip complex composed of LcrV. Though never directly observed, prevailing models assume that LcrV assists in the insertion of the pore-forming proteins YopB and YopD into the host cell membrane. This completes a bridge between the bacterium and host cell to provide a continuous channel through which effectors are delivered. Significant effort has gone into understanding how the T3SS is assembled, how its substrates are recognized and how substrate delivery is controlled. Arguably the latter topic is the least understood; however, recent advances have provided new insight, and therefore, this review will focus primarily on summarizing the current state of knowledge regarding the control of substrate delivery by the T3SS. Specifically, we will discuss the roles of YopK, as well as YopN and YopE, which have long been linked to regulation of translocation. We also propose models whereby the YopK regulator communicates with the basal body of the T3SS to control translocation. PMID:23390616
Kadoury, Samuel; Abi-Jaoudeh, Nadine; Levy, Elliot B.; Maass-Moreno, Roberto; Krücker, Jochen; Dalal, Sandeep; Xu, Sheng; Glossop, Neil; Wood, Bradford J.
2011-01-01
Purpose: To assess the feasibility of combined electromagnetic device tracking and computed tomography (CT)/ultrasonography (US)/fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) fusion for real-time feedback during percutaneous and intraoperative biopsies and hepatic radiofrequency (RF) ablation. Materials and Methods: In this HIPAA-compliant, institutional review board–approved prospective study with written informed consent, 25 patients (17 men, eight women) underwent 33 percutaneous and three intraoperative biopsies of 36 FDG-avid targets between November 2007 and August 2010. One patient underwent biopsy and RF ablation of an FDG-avid hepatic focus. Targets demonstrated heterogeneous FDG uptake or were not well seen or were totally inapparent at conventional imaging. Preprocedural FDG PET scans were rigidly registered through a semiautomatic method to intraprocedural CT scans. Coaxial biopsy needle introducer tips and RF ablation electrode guider needle tips containing electromagnetic sensor coils were spatially tracked through an electromagnetic field generator. Real-time US scans were registered through a fiducial-based method, allowing US scans to be fused with intraprocedural CT and preacquired FDG PET scans. A visual display of US/CT image fusion with overlaid coregistered FDG PET targets was used for guidance; navigation software enabled real-time biopsy needle and needle electrode navigation and feedback. Results: Successful fusion of real-time US to coregistered CT and FDG PET scans was achieved in all patients. Thirty-one of 36 biopsies were diagnostic (malignancy in 18 cases, benign processes in 13 cases). RF ablation resulted in resolution of targeted FDG avidity, with no local treatment failure during short follow-up (56 days). Conclusion: Combined electromagnetic device tracking and image fusion with real-time feedback may facilitate biopsies and ablations of focal FDG PET abnormalities that would be challenging with conventional image guidance. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101985/-/DC1 PMID:21734159
Lopez, A M; Sala-Blanch, X; Castillo, R; Hadzic, A
2014-01-01
The recommendations for the level of injection and ideal placement of the needle tip required for successful ultrasound-guided sciatic popliteal block vary among authors. A hypothesis was made that, when the local anesthetic is injected at the division of the sciatic nerve within the common connective tissue sheath, the block has a higher success rate than an injection outside the sheath. Thirty-four patients scheduled for hallux valgus repair surgery were randomized to receive either a sub-sheath block (n=16) or a peri-sheath block (n=18) at the level of the division of the sciatic nerve at the popliteal fossa. For the sub-sheath block, the needle was advanced out of plane until the tip was positioned between the tibial and peroneal nerves, and local anesthetic was then injected without moving the needle. For the peri-sheath block, the needle was advanced out of plane both sides of the sciatic nerve, to surround the sheath. Mepivacaine 1.5% and levobupivacaine 0.5% 30mL were used in both groups. The progression of motor and sensory block was assessed at 5min intervals. Duration of block was recorded. Adequate surgical block was achieved in all patients in the subsheath group (100%) compared to 12 patients (67%) in the peri-sheath group at 30min. Sensory block was achieved faster in the subsheath than peri-sheath (9.1±7.4min vs. 19.0±4.0; p<.001). Our study suggests that for successful sciatic popliteal block in less than 30min, local anesthetic should be injected within the sheath. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Velmurugan, N; Sooriaprakas, C; Jain, Preetham
2014-01-01
Objective: Immature teeth have a large apical opening and thin divergent or parallel dentinal walls; hence, with conventional needle irrigation there is a very high possibility of extrusion. This study was done to compare the apical extrusion of NaOCl in an immature root delivered using EndoVac and needle irrigation. Materials and Methods: Eighty freshly extracted maxillary central incisors were decoronated followed by access cavity preparation. Modified organotypic protocol was performed to create an open apex; then, the samples were divided into four groups (n=20): EndoVac Microcannula (group I), EndoVac Macrocannula (group II), NaviTip irrigation needle (group III) and Max-i-Probe Irrigating needle (group IV); 9.0 ml of 3% sodium hypochlorite was delivered slowly over a period of 60 seconds. Extruded irrigants were collected in a vial and analysed statistically. Results: Group I, group III and group IV showed 100% extrusion (20/20) but group II showed only 40% extrusion (8/20). The difference in this respect between group II and other groups was statistically significant (P<0.001). With regards to the volume of extrusion, group II had only 0.23 ml of extruded irrigant. Group I extruded 7.53ml of the irrigant. Group III and group IV extruded the entire volume of irrigant delivered. Conclusion: EndoVac Macrocannula resulted in the least extrusion of irrigant in immature teeth when compared to EndoVac Microcannula and conventional needle irrigation. PMID:25584055
Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.
Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R
2012-02-01
One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.
Huang, Chih-Chung; Chen, Ruimin; Tsui, Po-Hsiang; Zhou, Qifa; Humayun, Mark S; Shung, K Kirk
2009-10-07
A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33%PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 +/- 0.02 to 0.520 +/- 0.06 dB mm(-1) MHz(-1) corresponding to an increase in Young's modulus from 6 +/- 0.4 to 96 +/- 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse-echo test showed that a good performance in sensitivity was maintained after the vibration test.
Effect of atmospheric electricity on dry deposition of airborne particles from atmosphere
NASA Astrophysics Data System (ADS)
Tammet, H.; Kimmel, V.; Israelsson, S.
The electric mechanism of dry deposition is well known in the case of unattached radon daughter clusters that are unipolar charged and of high mobility. The problematic role of the electric forces in deposition of aerosol particles is theoretically examined by comparing the fluxes of particles carried by different deposition mechanisms in a model situation. The electric mechanism of deposition appears essential for particles of diameter 10-200 nm in conditions of low wind speed. The electric flux of fine particles can be dominant on the tips of leaves and needles even in a moderate atmospheric electric field of a few hundred V m -1 measured over the plane ground surface. The electric deposition is enhanced under thunderclouds and high voltage power lines. Strong wind suppresses the relative role of the electric deposition when compared with aerodynamic deposition. When compared with diffusion deposition the electric deposition appears less uniform: the precipitation particulate matter on the tips of leaves and especially on needles of top branches of conifer trees is much more intensive than on the ground surface and electrically shielded surfaces of plants. The knowledge of deposition geometry could improve our understanding of air pollution damage to plants.
Watanabe, Kisaki; Shimizu, Nobuhiro
2015-09-01
The exotic insect pest Corythucha marmorata (Uhler) is increasingly spreading in Japan using the weed Solidago canadensis L. as a major host plant. The nymphs form colonies on the backs of leaves where they crowd together; however, aggregation does not occur in the adults. When an individual nymph is crushed using a needle tip and further the needle tip covered with the nymph's bodily fluids is moved slowly toward the center of the crowd, the surrounding nymphs display an escape behavior and their aggregation is disrupted. We detected geraniol as a nymph-specific volatile component. Bioassay results indicated that geraniol was effective as an alarm pheromone on second to fifth instar nymphs. Furthermore, we found that male and female adults responded sensitively to the alarm pheromone produced by nymphs. These results suggest that although the adult insects do not secrete geraniol, they can detect it produced by nymphs, thereby retaining the ability to escape from danger while suppressing the cost of geraniol production. The present study is the first to demonstrate that an alarm pheromone secreted by nymphs is also effective in adults among Tingidae.
Thin layer chromatography-ion mobility spectrometry (TLC-IMS).
Ilbeigi, Vahideh; Tabrizchi, Mahmoud
2015-01-06
Ion mobility spectrometry (IMS) is a fast and sensitive analytical method which operates at the atmospheric pressure. To enhance the capability of IMS for the analysis of mixtures, it is often used with preseparation techniques, such as GC or HPLC. Here, we report for the first time the coupling of the thin-layer chromatography and IMS. A variety of coupling schemes were tried that included direct electrospray from the TLC strip tip, indirect electrospray from a needle connected to the TLC strip, introducing the moving solvent into the injection port, and, the simplest way, offline introduction of scratched or cut pieces of strips into the IMS injection port. In this study a special solvent tank was designed and the TLC strip was mounted horizontally where the solvent would flow down. A very small funnel right below the TLC tip collected the solvent and transferred it to a needle via a capillary tubing. Using the TLC-ESI-IMS technique, acceptable separations were achieved for two component mixtures of morphine-papaverine and acridine-papaverine. A special injection port was designed to host the pieces cut off the TLC. The method was successfully used to identify each spot on the TLC by IMS in a few seconds.
NASA Astrophysics Data System (ADS)
Van De Water, P. K.
2016-12-01
The size, frequency, and morphology of leaf surface stomata is used to reconstruct past levels of atmospheric carbon dioxide over geologic time. This technique relies on measuring cell and cell-clusters to correlate with changes of known carbon dioxide levels in the atmosphere. Unfortunately, not all plants are suitable because the occurrence and placement of stomatal cell-complexes differ significantly between plant families. Monocot and dicot angiosperms exhibit different types of stomata and stomatal complexes that lack order and thus are unsuitable. But, in gymnosperms, the number and distribution of stomata and pavement cells is formalized and can be used to reconstruct past atmospheric carbon dioxide levels. However, characteristic of each plant species must still be considered. For example, conifers are useful but are divided into two-needle to five-needle pines, or have irregular surface morphology (Pseudotsuga sp. and Tsuga sp. needles). This study uses Pinus monophylla an undivided needle morphology, that being a cylinder has no interior surface cells. Pinus monophylla (single needle pinyon) needles were collected along Geiger Grade (Nevada State Highway 341, Reno) in 2005 and 2013 from 1500m to 2195m. Herbarium samples were also collected from 13 historic collections made between 1911 and 1994. The study determined changes with elevation and/or over time using in these populations. Using Pinus monophylla, insured needles represented a single surface with stomata, stomatal complex cells, and co-occurring pavement cell types. Results show decreased stomatal densities (stomata/area), stomatal index (stomata/stomata + epidermal cells) and stable stomata per row (stomata/row) . Epidermal cell density (Epidermal Cells /Area), and Pavement cell density (Pavement cell/area) track stomatal density similarly. Data comparison, using elevation in the 2005 and 2013 collections showed no-significant trends. Individual stomatal complexes show no differences in the size and shape over time or with elevation. Stomata morphology and the stomatal pores appear conservative. However some complex cells show a morphology suggesting they are not fully formed and functional. These characteristics appear often in the modern material suggesting some stomata never fully develop.
Siegenthaler, Andreas; Haug, Matthias; Eichenberger, Urs; Suter, Marc Rene; Moriggl, Bernhard
2013-05-01
Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks. Wiley Periodicals, Inc.
Kameoka, S; Matsumoto, K; Kai, Y; Yonehara, Y; Arai, Y; Honda, K
2010-01-01
The aim of the report was to establish puncture techniques for the temporomandibular joint (TMJ) cavity in rats. The experimental sample comprised 30 male Sprague–Dawley rats. Under general anaesthesia the superior joint cavity of the rat was punctured either laterally (lateral puncture technique (LPT), n = 11), anteriorly (anterosuperior puncture technique (ASPT), n = 13) or anteroinferior puncture technique (AIPT), n = 6) using a 27-gauge needle. After the tip of the needle was confirmed by micro-CT (R-mCT®, Rigaku, Tokyo, Japan) located on the mandibular fossa, 0.05 ml of contrast media was injected under micro-CT fluoroscopic guidance. After confirmation that the joint cavity was filled with contrast media, micro-CT imaging was carried out. The puncture for LPT was accurate in 5 of the 11 animals. The ASPT was accurate in all 13 animals. The AIPT punctured 3 of the 6 animals. Furthermore, the ASPT and AIPT demonstrated improved preservation of the needle; it was harder to detach the needle, which led to greater stability. These results suggest that ASPT assisted by R-mCT® is useful for basic research, including drug discovery and pathogenesis of TMJ diseases. PMID:20841463
Deep Needle Procedures: Improving Safety With Ultrasound Visualization
Peabody, Christopher R.; Mandavia, Diku
2017-01-01
Abstract Promoting patient safety and increasing health care quality have dominated the health care landscape during the last 15 years. Health care regulators and payers are now tying patient safety outcomes and best practices to hospital reimbursement. Many health care leaders are searching for new technologies that not only make health care for patients safer but also reduce overall health care costs. New advances in ultrasonography have made this technology available to health care providers at the patient’s bedside. Point-of-care ultrasound assistance now aids providers with real-time diagnosis and with visualization for procedural guidance. This is especially true for common deep needle procedures such as central venous catheter insertion, thoracentesis, and paracentesis. There is now mounting evidence that clinician-performed point-of-care ultrasound improves patient safety, enhances health care quality, and reduces health care cost for deep needle procedures. Furthermore, the miniaturization, ease of use, and the evolving affordability of ultrasound have now made this technology widely available. The adoption of point-of-care ultrasonography has reached a tipping point and should be seriously considered the safety standard for all hospital-based deep needle procedures. PMID:24786918
Influence of the capillary on the ignition of the transient spark discharge
NASA Astrophysics Data System (ADS)
Gerling, T.; Hoder, T.; Brandenburg, R.; Bussiahn, R.; Weltmann, K.-D.
2013-04-01
A self-pulsing negative dc discharge in argon generated in a needle-to-plane geometry at open atmosphere is investigated. Additionally, the needle electrode can be surrounded by a quartz capillary. It is shown that the relative position of the capillary end to the needle tip strongly influences the discharge inception and its spatio-temporal dynamics. Without the capillary for the selected working parameters a streamer corona is ignited, but when the capillary surrounds the needle, the transient spark (TS) discharge is ignited after a pre-streamer (PS) occurs. The time between PS and TS discharge depends on the relative capillary end position. The existence of the PS is confirmed by electro-optical characterization. Furthermore, spectrally and spatio-temporally resolved cross-correlation spectroscopy is applied to show the most active region of pre-phase emission activity as indicators for high local electric field strength. The results indicate that with a capillary in place, the necessary energy input of the pre-phase into the system is mainly reduced by additional electrical fields at the capillary edge. Even such a small change as a shift of dielectric surface close to the plasma largely changes the energy balance in the system.
Adam, Ahmed
2017-01-01
Objective To describe a simple, novel method to achieve ureteric access in the Cohen crossed reimplanted ureter, which will allow retrograde working access via the conventional transurethral method. Materials and Methods Under cystoscopic vision, suprapubic needle puncture was performed. The needle was directed (bevel facing) towards the desired ureteric orifice (UO). A guidewire (with a floppy-tip) was then inserted into the suprapubic needle passing into the bladder, and then easily passed into the crossed-reimplanted UO. The distal end of the guidewire was then removed through the urethra with cystoscopic grasping forceps. The straightened ureter then easily facilitated ureteroscopy access, retrograde pyelogram studies, and JJ stent insertion in a conventional transurethral method. Results The UO and ureter were aligned in a more conventional orthotopic course, to allow for conventional transurethral working access. Conclusion A novel method to access the Cohen crossed reimplanted ureter was described. All previously published methods of accessing the crossed ureter were critically appraised. PMID:29463976
Systematic assessment of microneedle injection into the mouse cornea
2012-01-01
Background Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Methods Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. Results A mean corneal area of 5.0 ±1.4 mm2 (mean ± SD) and 7.7 ±1.4 mm2 was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Conclusions Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved. PMID:22716296
Systematic assessment of microneedle injection into the mouse cornea.
Matthaei, Mario; Meng, Huan; Bhutto, Imran; Xu, Qingguo; Boelke, Edwin; Hanes, Justin; Jun, Albert S
2012-06-20
Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.
A needle guidance system for biopsy and therapy using two-dimensional ultrasound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat
2008-02-15
Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsymore » procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.« less
Localized Plasma Processing of Materials Using Atmospheric-Pressure Microplasma Jets
NASA Astrophysics Data System (ADS)
Yoshiki, Hiroyuki; Ikeda, Koichi; Wakaki, Akihiro; Togashi, Seisuke; Taniguchi, Kazutake; Horiike, Yasuhiro
2003-06-01
An atmospheric-pressure microplasma jet (μ-PJ) using RF (13.56 MHz) corona discharge was generated at the tip of a stainless steel surgical needle of 0.4 mm outer diameter at a RF power of 6-14 W. The needle functions as both a powered electrode and a narrow nozzle. The μ-PJ with a gas mixture of He/SF6/O2 was applied to localized Si etching. The etched profile exhibited an isotropic shape and the etch rate had a maximum value at the total gas flow rate of about 600 sccm and the SF6 concentration of 5%. The etch rate of 170 μm/min was obtained at a RF power of 14 W.
Bui, Huu Phuoc; Tomar, Satyendra; Courtecuisse, Hadrien; Audette, Michel; Cotin, Stéphane; Bordas, Stéphane P A
2018-05-01
An error-controlled mesh refinement procedure for needle insertion simulations is presented. As an example, the procedure is applied for simulations of electrode implantation for deep brain stimulation. We take into account the brain shift phenomena occurring when a craniotomy is performed. We observe that the error in the computation of the displacement and stress fields is localised around the needle tip and the needle shaft during needle insertion simulation. By suitably and adaptively refining the mesh in this region, our approach enables to control, and thus to reduce, the error whilst maintaining a coarser mesh in other parts of the domain. Through academic and practical examples we demonstrate that our adaptive approach, as compared with a uniform coarse mesh, increases the accuracy of the displacement and stress fields around the needle shaft and, while for a given accuracy, saves computational time with respect to a uniform finer mesh. This facilitates real-time simulations. The proposed methodology has direct implications in increasing the accuracy, and controlling the computational expense of the simulation of percutaneous procedures such as biopsy, brachytherapy, regional anaesthesia, or cryotherapy. Moreover, the proposed approach can be helpful in the development of robotic surgeries because the simulation taking place in the control loop of a robot needs to be accurate, and to occur in real time. Copyright © 2018 John Wiley & Sons, Ltd.
Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
Abayazid, Momen; Moreira, Pedro; Shahriari, Navid; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2015-01-01
In this paper, we present a system capable of automatically steering a bevel-tipped flexible needle under ultrasound guidance toward a physical target while avoiding a physical obstacle embedded in gelatin phantoms and biological tissue with curved surfaces. An ultrasound pre-operative scan is performed for three-dimensional (3D) target localization and shape reconstruction. A controller based on implicit force control is developed to align the transducer with curved surfaces to assure the maximum contact area, and thus obtain an image of sufficient quality. We experimentally investigate the effect of needle insertion system parameters such as insertion speed, needle diameter and bevel angle on target motion to adjust the parameters that minimize the target motion during insertion. A fast sampling-based path planner is used to compute and periodically update a feasible path to the target that avoids obstacles. We present experimental results for target reconstruction and needle insertion procedures in gelatin-based phantoms and biological tissue. Mean targeting errors of 1.46 ± 0.37 mm, 1.29 ± 0.29 mm and 1.82 ± 0.58 mm are obtained for phantoms with inclined, curved and combined (inclined and curved) surfaces, respectively, for insertion distance of 86–103 mm. The achieved targeting errors suggest that our approach is sufficient for targeting lesions of 3 mm radius that can be detected using clinical ultrasound imaging systems. PMID:25455165
[Morphology determination of ionization region in multi-needle-to-plate negative corona discharge].
Su, Peng-Hao; Zhu, Yi-Min; Chen, Hai-Feng
2007-11-01
Based on the former work on the current-voltage characteristics of a multi-needle-to-plate negative corona discharge at atmospheric pressure, the present work uses the method of OES (optical emission spectrum) for measuring N2 emission spectrum, and the morphology determination of the ionization region has been investigated. According to the distribution of N2 second positive band's intensity I(SPB), the highest of all bands, the outline of the ionization region was drawn fairly accurately. The relationship between I(SPB) and discharge current I can be obtained through the volume integral of the I(SPB). The experimental results show that the size of the ionization region enhances with the rise of the applied voltage U, and the electron avalanche begins at about 1 mm off the tips of needle electrode and multiplies only in the range of several millimeters, indicating that, the range of the ionization region is at the magnitude of mm. The electron avalanche along the axis of the needle develops farther than that along the radial direction of needle, and the shape of the ionization region looks like a bullet. The integral of I(SPB) is second-order linear to I, with a very second order coefficient, meaning that the main excited substance is N2. Energetic electrons mainly exist in ionization region while ions are the main charged particles to form discharge current in the transfer region.
Image-based tracking of the suturing needle during laparoscopic interventions
NASA Astrophysics Data System (ADS)
Speidel, S.; Kroehnert, A.; Bodenstedt, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.
2015-03-01
One of the most complex and difficult tasks for surgeons during minimally invasive interventions is suturing. A prerequisite to assist the suturing process is the tracking of the needle. The endoscopic images provide a rich source of information which can be used for needle tracking. In this paper, we present an image-based method for markerless needle tracking. The method uses a color-based and geometry-based segmentation to detect the needle. Once an initial needle detection is obtained, a region of interest enclosing the extracted needle contour is passed on to a reduced segmentation. It is evaluated with in vivo images from da Vinci interventions.
Curing and Characterization of Siloxanecarbonate Polymers
1980-01-01
to 93 percent yields of p-bromophenol-Z-tetrahydropyranyl ether. The Grignard reagent made from the protected phenol in tetrahydrofuran was added to...iodomethane and heating. When all of the magnesium appeared to have been consumed, the resulting Grignard reagent was added via a double-tipped needle...7-dichlorooctamethyltetrasiloxane via the Grignard reaction. Workup of the reaction product with aqueous ammonium chloride solution kept the molecule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsauo, Jiaywei, E-mail: 80732059@qq.com; Luo, Xuefeng, E-mail: luobo-913@126.com; Ye, Linchao, E-mail: linchao.ye@siemens.com
2015-06-15
PurposeThis study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS).Methods3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate themore » angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients.ResultsFailure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures.ConclusionsAdjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.« less
Shin, Jaehyuck; Kim, Yong Chul; Lee, Sang Chul; Kim, Jae Hun
2013-11-01
Transforaminal epidural steroid injection (TFESI) is a useful treatment modality for pain management. Most complications of TFESI are minor and transient. However, there is a risk of serious complications such as nerve injury, spinal cord infarct, or paraplegia. Some of the risks are related to direct injury to the vessel or intravascular injection of the particulate steroid. We prospectively tested the hypothesis that the intravascular injection rate of the Whitacre needle is lower than that of the Quincke needle during TFESI. This study was a randomized trial of 1376 TFESIs at the S1 level. We collected data of age, gender, height, weight, laterality (right/left), history of lumbosacral spine operation, history of appropriate interval discontinuation of anticoagulation medicines, and underlying disease. During the S1 TFESI, intrasacral bone contact, a blood aspiration test, and real-time fluoroscopy of the intravascular injection using contrast media were investigated. There were no significant differences in the intravascular injection rate with respect to age, gender, height, weight, hypertension, diabetes mellitus, laterality, history of lumbosacral spine operation, or history of appropriate interval discontinuation of anticoagulation medicines. Intravascular injection was significantly associated with a blood aspiration test (P < 0.001), needle tip type (P = 0.002), intrasacral bone contact (P < 0.001), and physicians (some P < 0.05). The use of Quincke needles and intrasacral bone contact increased the rate of intravascular injection. To reduce the risk of intravascular injection, the use of Whitacre needles without intrasacral bone contact may be a safer and more effective approach.
SU-F-J-10: Sliding Mode Control of a SMA Actuated Active Flexible Needle for Medical Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podder, T
Purpose: In medical interventional procedures such as brachytherapy, ablative therapies and biopsy precise steering and accurate placement of needles are very important for anatomical obstacle avoidance and accurate targeting. This study presents the efficacy of a sliding mode controller for Shape Memory Alloy (SMA) actuated flexible needle for medical procedures. Methods: Second order system dynamics of the SMA actuated active flexible needle was used for deriving the sliding mode control equations. Both proportional-integral-derivative (PID) and adaptive PID sliding mode control (APIDSMC) algorithms were developed and implemented. The flexible needle was attached at the end of a 6 DOF robotic system.more » Through LabView programming environment, the control commands were generated using the PID and APIDSMC algorithms. Experiments with artificial tissue mimicking phantom were performed to evaluate the performance of the controller. The actual needle tip position was obtained using an electromagnetic (EM) tracking sensor (Aurora, NDI, waterloo, Canada) at a sampling period of 1ms. During experiment, external disturbances were created applying force and thermal shock to investigate the robustness of the controllers. Results: The root mean square error (RMSE) values for APIDSMC and PID controllers were 0.75 mm and 0.92 mm, respectively, for sinusoidal reference input. In the presence of external disturbances, the APIDSMC controller showed much smoother and less overshooting response compared to that of the PID controller. Conclusion: Performance of the APIDSMC was superior to the PID controller. The APIDSMC was proved to be more effective controller in compensating the SMA uncertainties and external disturbances with clinically acceptable thresholds.« less
NASA Astrophysics Data System (ADS)
Gonzalez, David A.; Hardy, Luke A.; Hutchens, Thomas C.; Irby, Pierce B.; Fried, Nathaniel M.
2018-02-01
This study characterizes laser-induced vapor bubbles for five distal fiber optic tip configurations, to provide insight into stone retropulsion experienced during laser ablation of kidney stones. A TFL with 1908-nm wavelength delivered 34 mJ energy per pulse at 500-μs pulse duration through five different fibers: 100-μm-core/170-μm-OD bare fiber tip, 150-μm- to 300-μm-core tapered fiber tip, 100-μm-core/300-μm-OD ball tip fiber, 100-μm-core/340- μm-OD hollow steel tip fiber, and 100-μm-core/560-μm-OD muzzle brake fiber tip. A high speed camera with 10- μm spatial and 9.5-μs temporal resolution imaged vapor bubble dynamics. A needle hydrophone measured pressure transients in forward (0°) and side (90°) directions while placed at a 6.8 +/- 0.4 mm distance from fiber tip. Maximum bubble dimensions (width/length) averaged 0.7/1.5, 1.0/1.6, 0.5/1.1, 0.8/1.9, and 0.7/1.5 mm, for bare, tapered, ball, hollow steel, and muzzle tips, respectively (n=5). The hollow steel tip exhibited the most elongated vapor bubble shape, translating into increased forward pressure in this study and consistent with higher stone retropulsion in previous reports. Relative pressures (a.u.) in (forward/side) directions averaged 1.7/1.6, 2.0/2.0, 1.4/1.2, 6.8/1.1, and 0.3/1.2, for each fiber tip (n=5). For hollow steel tip, forward pressure was 4× higher than for bare fiber. For the muzzle brake fiber tip, forward pressure was 5× lower than for bare fiber. Bubble dimensions and pressure measurements demonstrated that the muzzle tip reduced forward pressure by partially venting vapors through side holes, consistent with lower stone retropulsion observed in previous reports.
Zelter, Alex; Riffle, Michael; MacCoss, Michael J.; Asbury, Charles L.; Davis, Trisha N.
2018-01-01
Accurate segregation of chromosomes relies on the force-bearing capabilities of the kinetochore to robustly attach chromosomes to dynamic microtubule tips. The human Ska complex and Ndc80 complex are outer-kinetochore components that bind microtubules and are required to fully stabilize kinetochore–microtubule attachments in vivo. While purified Ska complex tracks with disassembling microtubule tips, it remains unclear whether the Ska complex–microtubule interaction is sufficiently strong to make a significant contribution to kinetochore–microtubule coupling. Alternatively, Ska complex might affect kinetochore coupling indirectly, through recruitment of phosphoregulatory factors. Using optical tweezers, we show that the Ska complex itself bears load on microtubule tips, strengthens Ndc80 complex-based tip attachments, and increases the switching dynamics of the attached microtubule tips. Cross-linking mass spectrometry suggests the Ska complex directly binds Ndc80 complex through interactions between the Ska3 unstructured C-terminal region and the coiled-coil regions of each Ndc80 complex subunit. Deletion of the Ska complex microtubule-binding domain or the Ska3 C terminus prevents Ska complex from strengthening Ndc80 complex-based attachments. Together, our results indicate that the Ska complex can directly strengthen the kinetochore–microtubule interface and regulate microtubule tip dynamics by forming an additional connection between the Ndc80 complex and the microtubule. PMID:29487209
A method to incorporate interstitial components into the TPS gynecologic rigid applicator library.
Otal, Antonio; Richart, Jose; Rodriguez, Silvia; Santos, Manuel; Perez-Calatayud, Jose
2017-02-01
T2 magnetic resonance imaging (MRI) is recommended as the imaging modality for image-guided brachytherapy. In locally advanced cervical carcinoma, combined endocavitary and interstitial applicators are appropriate (Vienna or Utrecht). To cover extensive disease, Template Benidorm (TB) was developed. Treatment planning system applicator libraries are currently unavailable for the Utrecht applicator or the TB. The purpose of this work is to develop an applicator library for both applicators. The library developed in this work has been used in the Oncentra Brachytherapy TPS, version 4.3.0, which has a brachytherapy module that includes a library of rigid applicators. To add the needles of the Utrecht applicator and to model the TB, we used FreeCAD and MeshLab. The reconstruction process was based on the points that the rigid section and the interstitial part have in common. This, together with the free length, allowed us to ascertain the position of the tip. In case of the Utrecht applicator, one of the sources of uncertainty in the reconstruction was determining the distance of the tip of needle from the ovoid. In case of the TB, the large number of needles involved made their identification time consuming. The developed library resolved both issues. The developed library for the Utrecht and TB is feasible and efficient improving accuracy. It allows all the required treatment planning to proceed using just a T2 MRI sequence. The additional use of specific free available software applications makes it possible to add this information to the already existing library of the Oncentra Brachytherapy TPS. Specific details not included on this manuscript will be available under request. This library is also currently being implemented also into the Sagiplan v 2.0 TPS.
Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.
Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman
2013-10-01
Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.
Song, Hyun Beom; Lee, Kang Ju; Seo, Il Ho; Lee, Ji Yong; Lee, Sang-Mok; Kim, Jin Hyoung; Kim, Jeong Hun; Ryu, WonHyoung
2015-07-10
It has been challenging for microneedles to deliver drugs effectively to thin tissues with little background support such as the cornea. Herein, we designed a microneedle pen system, a single microneedle with a spring-loaded microneedle applicator to provide impact insertion. To firmly attach solid microneedles with 140 μm in height at the end of macro-scale applicators, a transfer molding process was employed. The fabricated microneedle pens were then applied to mouse corneas. The microneedle pens successfully delivered rhodamine dye deep enough to reach the stromal layer of the cornea with small entry only about 1000 μm(2). When compared with syringes or 30 G needle tips, microneedle pens could achieve more localized and minimally invasive delivery without any chances of perforation. To investigate the efficacy of microneedle pens as a way of drug delivery, sunitinib malate proven to inhibit in vitro angiogenesis, was delivered to suture-induced angiogenesis model. When compared with delivery by a 30 G needle tip dipped with sunitinib malate, only delivery by microneedle pens could effectively inhibit corneal neovascularization in vivo. Microneedle pens could effectively deliver drugs to thin tissues without impairing merits of using microneedles: localized and minimally invasive delivery. Copyright © 2015 Elsevier B.V. All rights reserved.
Saallah, Suryani; Naim, M Nazli; Mokhtar, Mohd Noriznan; Abu Bakar, Noor Fitrah; Gen, Masao; Lenggoro, I Wuled
2014-10-01
In this study, the potential of electrohydrodynamic atomization or electrospraying to produce nanometer-order CGTase particles from aqueous suspension was demonstrated. CGTase enzyme was prepared in acetate buffer solution (1% v/v), followed by electrospraying in stable Taylor cone-jet mode. The deposits were collected on aluminium foil (collector) at variable distances from the tip of spraying needle, ranging from 10 to 25 cm. The Coulomb fission that occurs during electrospraying process successfully transformed the enzyme to the solid state without any functional group deterioration. The functional group verification was conducted by FTIR analysis. Comparison between the deposit and the as-received enzyme in dry state indicates almost identical spectra. By increasing the distance of the collector from the needle tip, the average particle size of the solidified enzyme was reduced from 200±117 nm to 75±34 nm. The average particle sizes produced from the droplet fission were in agreement with the scaling law models. Enzyme activity analysis showed that the enzyme retained its initial activity after the electrospraying process. The enzyme particles collected at the longest distance (25 cm) demonstrated the highest enzyme activity, which indicates that the activity was controlled by the enzyme particle size. Copyright © 2014 Elsevier Inc. All rights reserved.
To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions
But, David Yiu-Kuen; Poley, Jan-Werner
2014-01-01
Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337
Tissue type determination by impedance measurement: A bipolar and monopolar comparison
Sharp, Jack; Bouazza-Marouf, Kaddour; Noronha, Dorita; Gaur, Atul
2017-01-01
Background: In certain medical applications, it is necessary to be able to determine the position of a needle inside the body, specifically with regards to identifying certain tissue types. By measuring the electrical impedance of specific tissue types, it is possible to determine the type of tissue the tip of the needle (or probe) is at. Materials and Methods: Two methods have been investigated for electric impedance detection; bipolar and monopolar. Commercially available needle electrodes are of a monopolar type. Although many patents exist on the bipolar setups, these have not as yet been commercialized. This paper reports a comparison of monopolar and bipolar setups for tissue type determination. In vitro experiments were carried out on pork to compare this investigation with other investigations in this field. Results: The results show that both monopolar and bipolar setups are capable of determining tissue type. However, the bipolar setup showed slightly better results; the difference between the different soft tissue type impedances was greater compared to the monopolar method. Conclusion: Both monopolar and bipolar electrical impedance setups work very similarly in inhomogeneous volumes such as biological tissue. There is a clear potential for clinical applications with impedance-based needle guidance, with both the monopolar and bipolar setups. It is, however, worth noting that the bipolar setup is more versatile. PMID:28217047
Paeng, Dong-Guk; Chang, Jin Ho; Chen, Ruimin; Humayun, Mark S.; Shung, K. Kirk
2009-01-01
High frequency ultrasound over 40 MHz has been used to image the anterior segment of the eye, but it is not suitable for the posterior segment due to the frequency-dependent attenuation of ultrasound and thus the limitation of penetration depth. This paper proposes a novel scan method to image the posterior segment of the eye with an angled high frequency (beyond 40 MHz) ultrasound needle transducer. In this method, the needle transducer is inserted into the eye through a small incision hole (∼1 mm in diameter) and rotated around the axial direction to form a cone-shaped imaging plane, allowing the spatial information of retinal vessels and diagnosis of their occlusion to be displayed. The feasibility of this novel technique was tested with images of a wire phantom, a polyimide tube, and an excised pig eye obtained by manually rotating a 40-MHz PMN-PT needle transducer with a beveled tip of 45°. From the results, we believe that rotational scan imaging will help expand the minimally invasive applications of high frequency ultrasound to other areas due to the capability of increased closeness of an angled needle transducer to structures of interest buried in other tissues. PMID:19411226
Paeng, Dong-Guk; Chang, Jin Ho; Chen, Ruimin; Humayun, Mark S; Shung, K Kirk
2009-03-01
High frequency ultrasound over 40 MHz has been used to image the anterior segment of the eye, but it is not suitable for the posterior segment due to the frequency dependent attenuation of ultrasound and thus the limitation of penetration depth. This paper proposes a novel scan method to image the posterior segment of the eye with an angled high frequency (beyond 40 MHz) ultrasound needle transducer. In this method, the needle transducer is inserted into the eye through a small incision hole (approximately 1 mm in diameter) and rotated around the axial direction to form a cone-shaped imaging plane, allowing the spatial information of retinal vessels and diagnosis of their occlusion to be displayed. The feasibility of this novel technique was tested with images of a wire phantom, a polyimide tube, and an excised pig eye obtained by manually rotating a 40-MHz PMN-PT needle transducer with a beveled tip of 45 degrees . From the results, we believe that rotational scan imaging will help expand the minimally invasive applications of high frequency ultrasound to other areas due to the capability of increased closeness of an angled needle transducer to structures of interest buried in other tissues.
Ma, Yurong; Aichmayer, Barbara; Paris, Oskar; Fratzl, Peter; Meibom, Anders; Metzler, Rebecca A.; Politi, Yael; Addadi, Lia; Gilbert, P. U. P. A.; Weiner, Steve
2009-01-01
The sea urchin tooth is a remarkable grinding tool. Even though the tooth is composed almost entirely of calcite, it is used to grind holes into a rocky substrate itself often composed of calcite. Here, we use 3 complementary high-resolution tools to probe aspects of the structure of the grinding tip: X-ray photoelectron emission spectromicroscopy (X-PEEM), X-ray microdiffraction, and NanoSIMS. We confirm that the needles and plates are aligned and show here that even the high Mg polycrystalline matrix constituents are aligned with the other 2 structural elements when imaged at 20-nm resolution. Furthermore, we show that the entire tooth is composed of 2 cooriented polycrystalline blocks that differ in their orientations by only a few degrees. A unique feature of the grinding tip is that the structural elements from each coaligned block interdigitate. This interdigitation may influence the fracture process by creating a corrugated grinding surface. We also show that the overall Mg content of the tooth structural elements increases toward the grinding tip. This probably contributes to the increasing hardness of the tooth from the periphery to the tip. Clearly the formation of the tooth, and the tooth tip in particular, is amazingly well controlled. The improved understanding of these structural features could lead to the design of better mechanical grinding and cutting tools. PMID:19332795
Ma, Yurong; Aichmayer, Barbara; Paris, Oskar; Fratzl, Peter; Meibom, Anders; Metzler, Rebecca A; Politi, Yael; Addadi, Lia; Gilbert, P U P A; Weiner, Steve
2009-04-14
The sea urchin tooth is a remarkable grinding tool. Even though the tooth is composed almost entirely of calcite, it is used to grind holes into a rocky substrate itself often composed of calcite. Here, we use 3 complementary high-resolution tools to probe aspects of the structure of the grinding tip: X-ray photoelectron emission spectromicroscopy (X-PEEM), X-ray microdiffraction, and NanoSIMS. We confirm that the needles and plates are aligned and show here that even the high Mg polycrystalline matrix constituents are aligned with the other 2 structural elements when imaged at 20-nm resolution. Furthermore, we show that the entire tooth is composed of 2 cooriented polycrystalline blocks that differ in their orientations by only a few degrees. A unique feature of the grinding tip is that the structural elements from each coaligned block interdigitate. This interdigitation may influence the fracture process by creating a corrugated grinding surface. We also show that the overall Mg content of the tooth structural elements increases toward the grinding tip. This probably contributes to the increasing hardness of the tooth from the periphery to the tip. Clearly the formation of the tooth, and the tooth tip in particular, is amazingly well controlled. The improved understanding of these structural features could lead to the design of better mechanical grinding and cutting tools.
Tip localization of an atomic force microscope in transmission microscopy with nanoscale precision
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumann, Fabian; Pippig, Diana A., E-mail: diana.pippig@physik.uni-muenchen.de; Gaub, Hermann E.
Since the atomic force microscope (AFM) has evolved into a general purpose platform for mechanical experiments at the nanoscale, the need for a simple and generally applicable localization of the AFM cantilever in the reference frame of an optical microscope has grown. Molecular manipulations like in single molecule cut and paste or force spectroscopy as well as tip mediated nanolithography are prominent examples for the broad variety of applications implemented to date. In contrast to the different kinds of superresolution microscopy where fluorescence is used to localize the emitter, we, here, employ the absorbance of the tip to localize itsmore » position in transmission microscopy. We show that in a low aperture illumination, the tip causes a significant reduction of the intensity in the image plane of the microscope objective when it is closer than a few hundred nm. By independently varying the z-position of the sample slide, we could verify that this diffraction limited image of the tip is not caused by a near field effect but is rather caused by the absorbance of the transmitted light in the low apex needle-like tip. We localized the centroid position of this tip image with a precision of better than 6 nm and used it in a feedback loop to position the tip into nano-apertures of 110 nm radius. Single-molecule force spectroscopy traces on the unfolding of individual green fluorescent proteins within the nano-apertures showed that their center positions were repeatedly approached with very high fidelity leaving the specific handle chemistry on the tip’s surface unimpaired.« less
NASA Astrophysics Data System (ADS)
Rodrigues, Pedro L.; Moreira, António H. J.; Rodrigues, Nuno F.; Pinho, A. C. M.; Fonseca, Jaime C.; Lima, Estevão.; Vilaça, João. L.
2014-03-01
Background: Precise needle puncture of renal calyces is a challenging and essential step for successful percutaneous nephrolithotomy. This work tests and evaluates, through a clinical trial, a real-time navigation system to plan and guide percutaneous kidney puncture. Methods: A novel system, entitled i3DPuncture, was developed to aid surgeons in establishing the desired puncture site and the best virtual puncture trajectory, by gathering and processing data from a tracked needle with optical passive markers. In order to navigate and superimpose the needle to a preoperative volume, the patient, 3D image data and tracker system were previously registered intraoperatively using seven points that were strategically chosen based on rigid bone structures and nearby kidney area. In addition, relevant anatomical structures for surgical navigation were automatically segmented using a multi-organ segmentation algorithm that clusters volumes based on statistical properties and minimum description length criterion. For each cluster, a rendering transfer function enhanced the visualization of different organs and surrounding tissues. Results: One puncture attempt was sufficient to achieve a successful kidney puncture. The puncture took 265 seconds, and 32 seconds were necessary to plan the puncture trajectory. The virtual puncture path was followed correctively until the needle tip reached the desired kidney calyceal. Conclusions: This new solution provided spatial information regarding the needle inside the body and the possibility to visualize surrounding organs. It may offer a promising and innovative solution for percutaneous punctures.
Liang, Xin M.; Sekar, Praveen K.; Zhao, Gang; Zhou, Xiaoming; Shu, Zhiquan; Huang, Zhongping; Ding, Weiping; Zhang, Qingchuan; Gao, Dayong
2015-01-01
An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Despite the previous belief, system calibration constant was observed to be highly temperature-dependent. Dynamic thermal conductivity response during cooling (40 °C to –40 °C) was observed using the miniaturized single tip sensor for various concentrations of CPAs, i.e., glycerol, ethylene glycol and dimethyl sulfoxide. Chicken breast, chicken skin, porcine limb, and bovine liver were assayed to investigate the effect of anatomical heterogeneity on thermal conductivity using the arrayed multi-tip sensor at 20 °C. Experimental results revealed distinctive differences in localized thermal conductivity, which suggests the use of approximated or constant property values is expected to bring about results with largely inflated uncertainties when investigating bio-heat transfer mechanisms and/or performing sophisticated thermal modeling with complex biological tissues. Overall, the presented micro thermal sensor with automated data analysis algorithm is a promising approach for direct thermal conductivity measurement of aqueous solutions and soft biomaterials and is of great value to cryopreservation of tissues, hyperthermia or cryogenic, and other thermal-based clinical diagnostics and treatments. PMID:25993037
NASA Astrophysics Data System (ADS)
Liang, Xin M.; Sekar, Praveen K.; Zhao, Gang; Zhou, Xiaoming; Shu, Zhiquan; Huang, Zhongping; Ding, Weiping; Zhang, Qingchuan; Gao, Dayong
2015-05-01
An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Despite the previous belief, system calibration constant was observed to be highly temperature-dependent. Dynamic thermal conductivity response during cooling (40 °C to -40 °C) was observed using the miniaturized single tip sensor for various concentrations of CPAs, i.e., glycerol, ethylene glycol and dimethyl sulfoxide. Chicken breast, chicken skin, porcine limb, and bovine liver were assayed to investigate the effect of anatomical heterogeneity on thermal conductivity using the arrayed multi-tip sensor at 20 °C. Experimental results revealed distinctive differences in localized thermal conductivity, which suggests the use of approximated or constant property values is expected to bring about results with largely inflated uncertainties when investigating bio-heat transfer mechanisms and/or performing sophisticated thermal modeling with complex biological tissues. Overall, the presented micro thermal sensor with automated data analysis algorithm is a promising approach for direct thermal conductivity measurement of aqueous solutions and soft biomaterials and is of great value to cryopreservation of tissues, hyperthermia or cryogenic, and other thermal-based clinical diagnostics and treatments.
Structure of the heterotrimeric complex that regulates type III secretion needle formation
Quinaud, Manuelle; Plé, Sophie; Job, Viviana; Contreras-Martel, Carlos; Simorre, Jean-Pierre; Attree, Ina; Dessen, Andréa
2007-01-01
Type III secretion systems (T3SS), found in several Gram-negative pathogens, are nanomachines involved in the transport of virulence effectors directly into the cytoplasm of target cells. T3SS are essentially composed of basal membrane-embedded ring-like structures and a hollow needle formed by a single polymerized protein. Within the bacterial cytoplasm, the T3SS needle protein requires two distinct chaperones for stabilization before its secretion, without which the entire T3SS is nonfunctional. The 2.0-Å x-ray crystal structure of the PscE-PscF55–85-PscG heterotrimeric complex from Pseudomonas aeruginosa reveals that the C terminus of the needle protein PscF is engulfed within the hydrophobic groove of the tetratricopeptide-like molecule PscG, indicating that the macromolecular scaffold necessary to stabilize the T3SS needle is totally distinct from chaperoned complexes between pilus- or flagellum-forming molecules. Disruption of specific PscG–PscF interactions leads to impairment of bacterial cytotoxicity toward macrophages, indicating that this essential heterotrimer, which possesses homologs in a wide variety of pathogens, is a unique attractive target for the development of novel antibacterials. PMID:17470796
NASA Astrophysics Data System (ADS)
Asimakoulas, L.; Karim, M. L.; Dostal, L.; Krcma, F.; Graham, W. G.; Field, T. A.
2016-09-01
Plasmas formed by 1 ms pulses of between 180 and 300 V applied to sharp pin-like electrodes immersed in saline solution have been imaged with a Photron SA-X2 fast framing camera and an Andor iStar 510 ICCD camera. Stainless steel, Tungsten and Gold electrodes were investigated with tip diameters of 30 μm, 1 μm and < 1 μ m respectively. As previously observed, a vapour layer forms around the electrode prior to plasma ignition. For gold and stainless steel lower voltages were required to minimize electrode damage. Preliminary anlaysis indicates at lower voltages for all tips the fast framing results show that light emission is normally centred on a single small volume, which appears to move about, but remains close to the tip. In the case of Tungsten with higher voltages or longer pulses the tip of the needle can heat up to incandescent temperatures. At higher voltages shock wave fronts appear to be observed as the vapour layer collapses at the end of the voltage pulse. Backlighting and no lighting to observe bubble/vapour layer formation and emission due to plasma formation were employed. Sometimes at higher voltages a thicker vapour layer engulfs the tip and no plasma emission/current is observed.
Tansatit, Tanvaa; Wisawasukmongchol, Wirach; Bunyavejchevin, Suvit
2006-07-01
The missile trocar was developed for smooth abdominal penetration of the primary port. It contains a longitudinal tunnel connecting the abdominal cavity with the outside. To evaluate the efficacy of the missile trocar compared with the traditional method using the Veress needle. The times required to enter the abdominal cavity and the difficulty of the procedure were compared with the traditional Veress needle. A blind technique was used on 100 consecutive patients in a randomized fashion. The missile trocar technique took 2.7 +/- 1.6 minutes to perform compared with 3.9 +/- 1.3 min in the Veress needle group (p = 0.001), and the difficulty of the procedure was 2.1 +/- 1.9 cm (p = 0.433) rated from 10-cm scale. No carbon dioxide leakage or serious complications occurred in any patient. The results of the present study indicate that a long-tip missile trocar technique may be used safely when the technique is fully understood. This procedure is a relatively quick alternative approach for laparoscopy.
Development of Compact, Modular Lunar Heat Flow Probes
NASA Technical Reports Server (NTRS)
Nagihara, S.; Zacny, K.; Hedlund, M.; Taylor, P. T.
2014-01-01
Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey and previously the International Lunar Network. Because the lander for such a mission will be relatively small, the heat flow instrumentation must be a low-mass and low-power system. The instrument needs to measure both thermal gradient and thermal conductivity of the regolith penetrated. It also needs to be capable of excavating a deep enough hole (approx. 3 m) to avoid the effect of potential long-term changes of the surface thermal environment. The recently developed pneumatic excavation system can largely meet the low-power, low-mass, and the depth requirements. The system utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. The thermal sensors consist of resistance temperature detectors (RTDs) embedded on the stem and an insitu thermal conductivity probe attached to the cone tip. The thermal conductivity probe consists of a short 'needle' (2.4-mm diam. and 15- to 20-mm length) that contains a platinum RTD wrapped in a coil of heater wire. During a deployment, when the penetrating cone reaches a desired depth, it stops blowing gas, and the stem pushes the needle into the yet-to-be excavated, undisturbed bottom soil. Then, it begins heating and monitors the temperature. Thermal conductivity of the soil can determined from the rate of temperature increase with time. When the measurement is complete, the system resumes excavation until it reaches the next targeted depth.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.
2017-03-01
Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.
McShane, John M; Nazarian, Levon N; Harwood, Marc I
2006-10-01
Chronic tendinosis of the common extensor tendon of the lateral elbow can be a difficult problem to treat. We report our experience with sonographically guided percutaneous needle tenotomy to relieve pain and improve function in patients with this condition. We performed sonographically guided percutaneous needle tenotomy on 58 consecutive patients who had persistent pain and disability resulting from common extensor tendinosis. Under a local anesthetic and sonographic guidance, a needle was advanced into the common extensor tendon, and the tip of the needle was used to repeatedly fenestrate the tendinotic tissue. Calcifications, if present, were mechanically fragmented, and the adjacent bony surface of the apex and face of the epicondyle were abraded. Finally, the fenestrated tendon was infiltrated with a solution containing corticosteroid mixed with bupivacaine. After the procedure, patients were instructed to perform passive stretches and to undergo physical therapy. During a subsequent telephone interview, patients answered questions about their experience, their functioning level, and their perceptions of procedure outcome. Fifty-five (95%) of 58 patients were contacted by telephone and agreed to participate in the study. Thirty-five (63.6%) of 55 respondents reported excellent outcomes, 16.4% good, 7.3% fair, and 12.7% poor. The average follow-up time from the date of the procedure to the date of the interview was 28 months (range, 17-44 months). No adverse events were reported; 85.5% stated that they would refer a friend or close relative for the procedure. Sonographically guided percutaneous needle tenotomy for lateral elbow tendinosis is a safe, effective, and viable alternative for patients in whom all other nonsurgical treatments failed.
Mechanical characteristics of plastic base Ports and impact on flushing efficacy.
Guiffant, Gérard; Flaud, Patrice; Royon, Laurent; Burnet, Espérie; Merckx, Jacques
2017-01-01
Three types of totally implantable venous access devices, Ports, are currently in use: titanium, plastic (polyoxymethylene, POM), and mixed (titanium base with a POM shell). Physics theory suggests that the interaction between a non-coring needle (NCN, made of stainless steel) and a plastic base would lead to the stronger material (steel) altering the more malleable material (plastic). To investigate whether needle impacts can alter a plastic base's surface, thus potentially reducing flushing efficacy. A Port made of POM was punctured 200 times with a 19-gauge NCN. Following the existing guidelines, the needle tip pricked the base with each puncture. The Port's base was then examined using a two-dimensional optical instrument, and a bi-dimensional numerical simulation using COMSOL ® was performed to investigate potential surface irregularities and their impact on fluid flow. Each needle impact created a hole (mean depth, 0.12 mm) with a small bump beside it (mean height, 0.02 mm) the Reynolds number Re k ≈10. A numerical simulation of the one hole/bump set showed that the flushing efficacy was 60% that of flushing along a flat surface. In clinical practice, the number of times a Port is punctured depends on patient and treatment characteristics, but each needle impact on the plastic base may increase the risk of decreased flushing effectiveness. Therefore, the more a plastic Port is accessed, the greater the risk of microorganisms, blood products, and medication accumulation. Multiple needle impacts created an irregular surface on the Port's base, which decreased flushing efficacy. Clinical investigation is needed to determine whether plastic base Ports are associated with an increased risk of Port infection and occlusion compared to titanium base Ports.
["Dual Guidance"? - parallel combination of ultrasound-guidance and nerve stimulation - Contra].
Maecken, Tim
2015-07-01
Sonography is a highly user-dependent technology. It presupposes a considerable degree of sonoanatomic and sonographic knowledge and requires good practical skills of the examiner. Sonography allows the identification of the puncture target, observes the needle feed and assesses the spread pattern of the local anesthetic in real time. Peripheral electrical nerve stimulation (PNS) cannot offer these advantages to the same degree, but may allow nerve localization under difficult sonographic conditions. The combination of the two locating techniques is complex in its practical implementation. Partially, the use of one location technique is made even more difficult by the combination with the second. PNS in parallel to sonography serves primarily as a warning technology in the case of an invisible cannula tip. It should not be construed as a compensation technique for the lack of sonographic skills or knowledge. However, PNS may be helpful in the sense of a bridging technology as long as the user is aware of its limitations. © Georg Thieme Verlag Stuttgart · New York.
A Simple and Inexpensive Device for Slow, Controlled Addition of a Solution to a Reaction Mixture
NASA Astrophysics Data System (ADS)
Osvath, Peter
1995-07-01
A number of reactions require the slow and controlled addition of a solution containing one reagent to another. Attempting to control the flow rate over a number of hours using a conventional constant pressure addition funnel is a frustrating exercise; commercially available constant volume addition funnels are expensive and must be adjusted by trial and error each time a reaction is carried out. The use of an (expensive) peristaltic pump or syringe pump overcomes these problems but can introduce other complications. We have recently had occasion to carry out the synthesis of thioether macrocycles and cages requiring the slow and controlled addition of DMF solutions of (offensively odoriferous) thiols or (air-sensitive) thiolates to a reactant solution under nitrogen(1), Although the use of a syringe pump was called for, there are obvious difficulties associated with purging the solution and assembling such an apparatus under nitrogen, and we report a simple and inexpensive solution. A Male Luer Lock tip (recovered from a broken syringe) was sweated onto the flattened tip of a pressure-equalizing addition funnel and a syringe needle was attached. Judicious selection of needle length, bore size, and reactant volume can be used to control the addition time simply and reproducibly. With a 250-mL funnel, the flow rate changes by <25% from the beginning to the end of the addition. (In fact, a reduction in the rate of addition may even be advantageous as the reaction proceeds, the reagent in the receiving flask is consumed, its concentration drops, and the rate of reaction will decrease). A piece of fine Teflon tubing of appropriate length attached to the needle can be used to reduce the flow rate even further, but this is only necessary for very slow rates of addition. For example, the time of addition of 200 mL, of an ethanolic solution could be varied from approximately 5 minutes (150mm/17 gauge) to approximately 5 h (200mm/22 gauge), and once the addition time for a particular needle length/bore is determined, the tap on the addition funnel is turned fully on, so no adjustment is necessary. When needles with a particularly fine bore are used, a small plug of glass wool should be inserted in the constriction above the tap, to filter the solution and prevent blockage of the needle. An inert atmosphere is readily maintained throughout the system. The elimination of atmospheric contamination, containment of odors and controlled slow addition have led to improved yields and less complaints from fellow inhabitants of the laboratory! Literature Cited 1. Osvath, P.; Sargeson, A. M.; Skelton, B. W.; White, A. H. J. Chem. Soc., Chem. Commun. 1991, 1036. Osvath. P.; Sargeson, A. J. Chem. Soc., Chem. Commun. 1993, 40.
Xu, Yongbin; Song, Saemee; Moeller, Arne; Kim, Nahee; Piao, Shunfu; Sim, Se-Hoon; Kang, Mooseok; Yu, Wookyung; Cho, Hyun-Soo; Chang, Iksoo; Lee, Kangseok; Ha, Nam-Chul
2011-04-15
Macrolide-specific efflux pump MacAB-TolC has been identified in diverse gram-negative bacteria including Escherichia coli. The inner membrane transporter MacB requires the outer membrane factor TolC and the periplasmic adaptor protein MacA to form a functional tripartite complex. In this study, we used a chimeric protein containing the tip region of the TolC α-barrel to investigate the role of the TolC α-barrel tip region with regard to its interaction with MacA. The chimeric protein formed a stable complex with MacA, and the complex formation was abolished by substitution at the functionally essential residues located at the MacA α-helical tip region. Electron microscopic study delineated that this complex was made by tip-to-tip interaction between the tip regions of the α-barrels of TolC and MacA, which correlated well with the TolC and MacA complex calculated by molecular dynamics. Taken together, our results demonstrate that the MacA hexamer interacts with TolC in a tip-to-tip manner, and implies the manner by which MacA induces opening of the TolC channel.
Xu, Yongbin; Song, Saemee; Moeller, Arne; Kim, Nahee; Piao, Shunfu; Sim, Se-Hoon; Kang, Mooseok; Yu, Wookyung; Cho, Hyun-Soo; Chang, Iksoo; Lee, Kangseok; Ha, Nam-Chul
2011-01-01
Macrolide-specific efflux pump MacAB-TolC has been identified in diverse Gram-negative bacteria including Escherichia coli. The inner membrane transporter MacB requires the outer membrane factor TolC and the periplasmic adaptor protein MacA to form a functional tripartite complex. In this study, we used a chimeric protein containing the tip region of the TolC α-barrel to investigate the role of the TolC α-barrel tip region with regard to its interaction with MacA. The chimeric protein formed a stable complex with MacA, and the complex formation was abolished by substitution at the functionally essential residues located at the MacA α-helical tip region. Electron microscopic study delineated that this complex was made by tip-to-tip interaction between the tip regions of the α-barrels of TolC and MacA, which correlated well with the TolC and MacA complex calculated by molecular dynamics. Taken together, our results demonstrate that the MacA hexamer interacts with TolC in a tip-to-tip manner, and implies the manner by which MacA induces opening of the TolC channel. PMID:21325274
Morawski, Ireneusz; Voigtländer, Bert
2010-03-01
We present combined noncontact scanning force microscopy and tunneling current images of a platinum(111) surface obtained by means of a 1 MHz quartz needle sensor. The low-frequency circuit of the tunneling current was combined with a high-frequency signal of the quartz resonator enabling full electrical operation of the sensor. The frequency shift and the tunneling current were detected simultaneously, while the feedback control loop of the topography signal was fed using one of them. In both cases, the free signal that was not connected to the feedback loop reveals proportional-integral controller errorlike behavior, which is governed by the time derivative of the topography signal. A procedure is proposed for determining the mechanical oscillation amplitude by utilizing the tunneling current also including the average tip-sample work function.
Asami, Tetsu; Kaneko, Hiroki; Miyake, Kensaku; Ota, Ichiro; Miyake, Goichiro; Kato, Seiichi; Yasuda, Shunsuke; Iwase, Takeshi; Ito, Yasuki; Terasaki, Hiroko
2016-01-01
Purpose We report a newly developed device to fragment thrombi in retinal vein occlusion. Methods The new instrument consists of a 23-gauge (G) pipe and a 37-G needle with an internal wire. A total of 40 porcine eyes were used; 20 eyes for experiments in the branch retinal vein (BRV group) and 20 eyes for experiments in the central retinal vein (CRV group). We placed 25-G 3-port trocars, and core vitrectomy was performed. Another 23-G scleral incision was performed for insertion of the needle. The needle pierced the retinal vein at a distance of three- to four- or one-disc diameters from the optic disc (BRV or CRV group, respectively), and the internal wire was advanced toward the disc. The success rates of needle piercing and cannulation of the internal wire were recorded in each group. In the CRV group, the cannulation was deemed successful when the tip reached inside the optic disc. Real-time optical coherence tomography imaging also was performed using the Zeiss Rescan 700 device in porcine eyes. Histologic examination of the retinal vessel inserted with the internal wire was performed. Results The success rates of needle piercing into the BRV and CRV were 85% and 95%, respectively. The success rates of cannulation of the internal wire into the BRV and CRV were 85% and 0%, respectively. The process of cannulation was recorded successfully with the Rescan 700. Histologic examination showed no damages to the endothelial cell layer. Conclusions The needle and internal wire intended to be used for recanalization of BRV occlusion were successfully pierced and cannulated into the BRV. Translational Relevance This newly developed device could become a treatment modality for retinal vein occlusion to fragment thrombi that present treatment methods cannot reach and remove directly. PMID:27730009
Zuo, Chang-Jing; Wang, Pei-Jun; Shao, Cheng-Wei; Wang, Min-Jie; Tian, Jian-Ming; Xiao, Yi; Ren, Fang-Yuan; Hao, Xi-Yan; Yuan, Min
2004-01-01
AIM: To explore the feasibility of computed tomography (CT)-guided percutaneous ethanol injection (PEI) using a disposable curved needle for treatment of malignant liver neoplasms and their metastases in retroperitoneal lymph nodes. METHODS: CT-guided PEI was conducted using a disposable curved needle in 26 malignant liver tumors smaller than 5 cm in diameter and 5 lymph node metastases of liver cancer in the retroperitoneal space. The disposable curved needle was composed of a straight trocar (21G) and stylet, a disposable curved tip (25 G) and a fine stylet. For the tumors found in deep sites and difficult to reach, or for hepatic masses inaccessible to the injection using a straight needle because of portal vein and bile ducts, the straight trocar was used at first to reach the side of the tumor. Then, the disposable curved needle was used via the trocar. When the needle reached the tumor center, appropriate amount of ethanol was injected. For relatively large malignant liver tumors, multi-point injection was carried out for a better distribution of the ethanol injected throughout the masses. The curved needle was also used for treatment of the metastasis in retroperitoneal lymph nodes blocked by blood vessels and inaccessible by the straight needle. RESULTS: All of the 26 liver tumors received 2 or more times of successful PEI, through which ethanol was distributed throughout the whole tumor mass. Effect of the treatment was monitored by contrast-enhanced multi-phase CT and magnetic resonance imaging (MRI) examinations three months later. Of the 18 lesions whose diameters were smaller than 3 cm, the necrotic change across the whole mass and that in most areas were observed in 15 and 3 tumors, respectively. Among the 8 tumors sizing up to 5 cm, 5 were completely necrotic and 3 largely necrotic. Levels of tumor seromarkers were significantly reduced in some of the cases. In 5 patients with metastases of liver cancer in retroperitoneal lymph nodes who received 1 to 3 times of PEI, all the foci treated were completely necrotic and smaller demonstrated by dynamic contrast-enhanced CT or MRI 3 months later. CONCLUSION: CT-guided PEI using a disposable curved needle is effective, time-saving and convenient, providing an alternative therapy for the treatment of malignant liver tumors and their retroperitoneal lymph node metastases. PMID:14695769
NASA Astrophysics Data System (ADS)
Gonzalez, David A.; Hardy, Luke A.; Hutchens, Thomas C.; Irby, Pierce B.; Fried, Nathaniel M.
2018-03-01
This study characterizes laser-induced vapor bubble dynamics for five different distal fiber optic tip configurations, to provide insight into stone retropulsion commonly experienced during laser ablation of kidney stones. A thulium fiber laser with 1908-nm wavelength delivered 34-mJ energy per pulse at 500-μs pulse duration through five different fibers such as 100-μm-core / 170-μm-OD bare fiber tip, 150- to 300-μm-core tapered fiber tip, 100-μm-core / 300-μm-OD ball tip fiber, 100-μm-core / 340-μm-OD hollow steel tip fiber, and 100-μm-core / 560-μm-OD muzzle brake fiber tip. A high-speed camera with 10-μm-spatial and 9.5-μs-temporal resolution was used to image the vapor bubble dynamics. A needle hydrophone measured pressure transients in the forward (0 deg) and side (90 deg) directions while placed at a 6.8 ± 0.4 mm distance from the distal fiber tip. Maximum bubble dimensions (width/length) averaged 0.7/1.5, 1.0/1.6, 0.5/1.1, 0.8/1.9, and 0.7 / 1.5 mm, for bare, tapered, ball, hollow steel, and muzzle brake fiber tips, respectively (n = 5). The hollow steel tip exhibited the most elongated vapor bubble shape, translating into increased forward pressure in this study and consistent with higher stone retropulsion in previous reports. Relative pressures (a.u.) in (forward/side) directions averaged 1.7/1.6, 2.0/2.0, 1.4/1.2, 6.8/1.1, and 0.3/1.2, for each fiber tip (n = 5). For the hollow steel tip, forward pressure was 4 × higher than for the bare fiber. For the muzzle brake fiber tip, forward pressure was 5 × lower than the bare fiber. Bubble dimensions and pressure measurements demonstrated that the muzzle brake fiber tip reduced forward pressure by partially venting vapors through the portholes, which is consistent with the observation of lower stone retropulsion in previous reports.
Role of T3SS-1 SipD Protein in Protecting Mice against Non-typhoidal Salmonella Typhimurium
Jneid, Bakhos; Moreau, Karine; Plaisance, Marc; Rouaix, Audrey; Dano, Julie
2016-01-01
Background Salmonella enterica species are enteric pathogens that cause severe diseases ranging from self-limiting gastroenteritis to enteric fever and sepsis in humans. These infectious diseases are still the major cause of morbidity and mortality in low-income countries, especially in children younger than 5 years and immunocompromised adults. Vaccines targeting typhoidal diseases are already marketed, but none protect against non-typhoidal Salmonella. The existence of multiple non-typhoidal Salmonella serotypes as well as emerging antibiotic resistance highlight the need for development of a broad-spectrum protective vaccine. All Salmonella spp. utilize two type III Secretion Systems (T3SS 1 and 2) to initiate infection, allow replication in phagocytic cells and induce systemic disease. T3SS-1, which is essential to invade epithelial cells and cross the barrier, forms an extracellular needle and syringe necessary to inject effector proteins into the host cell. PrgI and SipD form, respectively, the T3SS-1 needle and the tip complex at the top of the needle. Because they are common and highly conserved in all virulent Salmonella spp., they might be ideal candidate antigens for a subunit-based, broad-spectrum vaccine. Principal Findings We investigated the immunogenicity and protective efficacy of PrgI and SipD administered by subcutaneous, intranasal and oral routes, alone or combined, in a mouse model of Salmonella intestinal challenge. Robust IgG (in all immunization routes) and IgA (in intranasal and oral immunization routes) antibody responses were induced against both proteins, particularly SipD. Mice orally immunized with SipD alone or SipD combined with PrgI were protected against lethal intestinal challenge with Salmonella Typhimurium (100 Lethal Dose 50%) depending on antigen, route and adjuvant. Conclusions and Significance Salmonella T3SS SipD is a promising antigen for the development of a protective Salmonella vaccine, and could be developed for vaccination in tropical endemic areas to control infant mortality. PMID:27992422
Detection of needle to nerve contact based on electric bioimpedance and machine learning methods.
Kalvoy, Havard; Tronstad, Christian; Ullensvang, Kyrre; Steinfeldt, Thorsten; Sauter, Axel R
2017-07-01
In an ongoing project for electrical impedance-based needle guidance we have previously showed in an animal model that intraneural needle positions can be detected with bioimpedance measurement. To enhance the power of this method we in this study have investigated whether an early detection of the needle only touching the nerve also is feasible. Measurement of complex impedance during needle to nerve contact was compared with needle positions in surrounding tissues in a volunteer study on 32 subjects. Classification analysis using Support-Vector Machines demonstrated that discrimination is possible, but that the sensitivity and specificity for the nerve touch algorithm not is at the same level of performance as for intra-neuralintraneural detection.
Dry needling: a literature review with implications for clinical practice guidelines1
Dunning, James; Butts, Raymond; Mourad, Firas; Young, Ian; Flannagan, Sean; Perreault, Thomas
2014-01-01
Background: Wet needling uses hollow-bore needles to deliver corticosteroids, anesthetics, sclerosants, botulinum toxins, or other agents. In contrast, dry needling requires the insertion of thin monofilament needles, as used in the practice of acupuncture, without the use of injectate into muscles, ligaments, tendons, subcutaneous fascia, and scar tissue. Dry needles may also be inserted in the vicinity of peripheral nerves and/or neurovascular bundles in order to manage a variety of neuromusculoskeletal pain syndromes. Nevertheless, some position statements by several US State Boards of Physical Therapy have narrowly defined dry needling as an ‘intramuscular’ procedure involving the isolated treatment of ‘myofascial trigger points’ (MTrPs). Objectives: To operationalize an appropriate definition for dry needling based on the existing literature and to further investigate the optimal frequency, duration, and intensity of dry needling for both spinal and extremity neuromusculoskeletal conditions. Major findings: According to recent findings in the literature, the needle tip touches, taps, or pricks tiny nerve endings or neural tissue (i.e. ‘sensitive loci’ or ‘nociceptors’) when it is inserted into a MTrP. To date, there is a paucity of high-quality evidence to underpin the use of direct dry needling into MTrPs for the purpose of short and long-term pain and disability reduction in patients with musculoskeletal pain syndromes. Furthermore, there is a lack of robust evidence validating the clinical diagnostic criteria for trigger point identification or diagnosis. High-quality studies have also demonstrated that manual examination for the identification and localization of a trigger point is neither valid nor reliable between-examiners. Conclusions: Several studies have demonstrated immediate or short-term improvements in pain and/or disability by targeting trigger points (TrPs) using in-and-out techniques such as ‘pistoning’ or ‘sparrow pecking’; however, to date, no high-quality, long-term trials supporting in-and-out needling techniques at exclusively muscular TrPs exist, and the practice should therefore be questioned. The insertion of dry needles into asymptomatic body areas proximal and/or distal to the primary source of pain is supported by the myofascial pain syndrome literature. Physical therapists should not ignore the findings of the Western or biomedical ‘acupuncture’ literature that have used the very same ‘dry needles’ to treat patients with a variety of neuromusculoskeletal conditions in numerous, large scale randomized controlled trials. Although the optimal frequency, duration, and intensity of dry needling has yet to be determined for many neuromusculoskeletal conditions, the vast majority of dry needling randomized controlled trials have manually stimulated the needles and left them in situ for between 10 and 30 minute durations. Position statements and clinical practice guidelines for dry needling should be based on the best available literature, not a single paradigm or school of thought; therefore, physical therapy associations and state boards of physical therapy should consider broadening the definition of dry needling to encompass the stimulation of neural, muscular, and connective tissues, not just ‘TrPs’. PMID:25143704
Development of a needle driver with multiple degrees of freedom for neonatal laparoscopic surgery.
Ishimaru, Tetsuya; Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-07-01
The aims of this study were to develop a thin needle driver with multiple degrees of freedom and to evaluate its efficacy in multidirectional suturing compared with a conventional needle driver. The tip (15 mm) of the novel user-friendly needle driver (3.5 mm in diameter) has three degrees of freedom for grasping, rotation, and deflection. Six pediatric surgeons performed two kinds of suturing tasks in a dry box: three stitches in continuous suturing that were perpendicular or parallel to the insertion direction of the instrument, first using the novel instrument, then using a conventional instrument, and finally using the novel instrument again. The accuracy of insertion and exit compared with the target points and the procedure time were measured. In the conventional and novel procedures the mean gaps from the insertion point to the target in perpendicular suturing were 0.8 mm and 0.7 mm, respectively; in parallel suturing they were 0.8 mm and 0.6 mm, respectively. The mean gaps from the exit point to the target in perpendicular suturing were 0.6 mm and 0.6 mm for conventional and novel procedures, respectively; in parallel suturing they were 0.6 mm and 0.8 mm, respectively. The procedure time for perpendicular suturing was 33 seconds and 64 seconds for conventional and novel procedures, respectively (P=.02); for parallel suturing it was 114 seconds and 91 seconds, respectively. Our novel needle driver maintained accuracy of suturing; parallel suturing with the novel driver may be easier than with the conventional one.
Klauser, Andrea; De Zordo, Tobias; Feuchtner, Gudrun; Sögner, Peter; Schirmer, Michael; Gruber, Johann; Sepp, Norbert; Moriggl, Bernhard
2008-11-15
Sacroiliitis is often caused by rheumatic diseases, and besides other therapeutic options, treatment consists of intraarticular injection of corticosteroids. The purpose of this study was to assess the feasibility of ultrasound (US)-guided sacroiliac joint (SI joint) injection at 2 different puncture levels in cadavers and patients when defined sonoanatomic landmarks were considered. After defining sonoanatomic landmarks, US-guided needle insertion was performed in 10 human cadavers (20 SI joints) at 2 different puncture sites. Upper level was defined at the level of the posterior sacral foramen 1 and lower level at the level of the posterior sacral foramen 2. In 10 patients with unilateral sacroiliitis, injection at the most feasible level was attempted. Computed tomography confirmed correct intraarticular needle placement in cadavers by showing the tip of the needle in the joint and intraarticular diffusion of contrast media in 16 (80%) of 20 SI joints (upper level 7 [70%] of 10; lower level 9 [90%] of 10). In all 4 cases in which needle insertion failed, intraarticular SI joint injection at the other level was successful. In patients, 100% of US-guided injections were successful (8 lower level, 2 upper level), with a mean pain relief of 8.6 after 3 months. US guidance of needle insertion into SI joints was feasible at both levels when defined sonoanatomic landmarks were used. If SI joint alterations do not allow for direct visualization of the dorsal joint space of the lower level, which is easier to access, the upper level might offer an appropriate alternative.
Park, In-Seop; Kim, Sung-Jae
2006-08-01
We introduce a suture technique to repair a peripheral tear near the posterior tibial attachment of the posterior horn. A suture hook was inserted through the posteromedial portal, and the peripheral capsular rim was penetrated from superior to inferior by the sharp hook. Both relay limbs were brought out through the posteromedial portal. The outer limb of the superior peripheral capsular rim was identified with a hemostat. An 18-gauge spinal needle loaded with a No. 0 polydioxanone suture (PDS) was introduced into the joint from the anteromedial portal; it was passed through the joint space until it penetrated the inner torn meniscus. The PDS suture loaded within the needle was pushed into the joint and picked up through the posteromedial portal. The needle was pulled out of the torn meniscus and readvanced over it while the suture was kept loaded. The other limb of the suture from the tip of the spinal needle was retrieved through the posteromedial portal. The initial PDS suture limb was hooked to the shuttle-relay system; it then was passed through the inner torn meniscus and the peripheral capsular rim. The suture limb exiting from the peripheral capsular rim was used as a post and was joined to the other suture limb to form a sliding knot.
McShane, John M; Shah, Vinil N; Nazarian, Levon N
2008-08-01
Chronic refractory common extensor tendinosis of the lateral elbow has been shown to respond to sonographically guided percutaneous needle tenotomy (PNT) followed by corticosteroid injection. In this analysis, we attempted to determine whether the corticosteroid is a necessary component of the procedure. We performed PNT on 57 consecutive patients (age range, 34-61 years) with persistent pain and disability resulting from common extensor tendinosis. Under a local anesthetic and sonographic guidance, a needle was advanced into the tendon, and the tip of the needle was used to fenestrate the tendinotic tissue, break up any calcifications, and abrade the adjacent bone. After the procedure, patients underwent a specified physical therapy protocol. During a subsequent telephone interview, patients answered questions about their symptoms, the level of functioning, and perceptions of the procedure outcome. Of the 52 patients who agreed to participate in the study, 30 (57.7%) reported excellent outcomes, 18 (34.6%) good, 1 (1.9%) fair, and 3 (5.8%) poor. The average follow-up time from the date of the procedure to the telephone interview was 22 months (range, 7-38 months). No adverse events were reported, and 90% stated that they would refer a friend or close relative for the procedure. Sonographically guided PNT for refractory lateral elbow tendinosis is an effective procedure, and subsequent corticosteroid injection is not necessary.
2017-01-01
Purpose The aim of the study was to locate the infraorbital foramen (IOF) in relation to the infraorbital margin (IOM) for proper injections of local anesthetics in skull specimens. Another aim was to determine the depth of needle penetration into pterygopalatine fossa through the greater palatine canal (GPC). Materials and Methods 102 skull halves were used to measure the distances between (1) IOF and IOM and (2) IOF and alveolar ridge of maxilla at second premolar. Needles were inserted and bent at a 45° angle, passing through the GPC at the level of hard palate. The depth of the tip of needle emerging out of GPC into pterygopalatine fossa was measured. Results The mean distance between IOF and IOM was 6.46 ± 1.57 mm on the right side and 6.74 ± 1.72 mm on the left. The mean distance between IOF and alveolar bone process of the maxilla at second premolar was 29.07 ± 3.58 mm on the right side and 29.39 ± 3.78 mm on the left. The mean depth of penetration of the needle into the pterygopalatine fossa was similar on both sides. Conclusions Proper identification of IOF and pterygopalatine fossa is of great significance during local anesthesia injections, due to their close proximity to vital anatomic structures. PMID:29410916
TOP 08 2 503 Low Volatility Agent Permeation (LVAP) Swatch Testing
2018-02-20
tipped needle, Type 3, and a repeating Dispenser ( product PB-600), all manufactured by Hamilton® company, Reno, Nevada). TOP 08-2-503 20 February... Production Document CWA chemical warfare agent DA Department of the Army DEET N,N-diethyl-meta-toluamide DI deionized DoE design of experiment DPG U.S...under varying conditions of field use, storage, and/or environmental exposure(s). These procedures are designed to be used as part of an overall
2007-02-28
of magnitude in size. Also unlike corona -like devices such as the plasma needle , which generates 2-3 mm long plasma at the tip of a sharp wire...Distribution Unlimited Table of Contents Abstract AC System with Water Electrode Current voltage characteristics Plasma diagnostics results Experimental setup...Laroussi, PI. 4 AC SYSTEM WITH WATER ELECTRODE Recently, non-equilibrium atmospheric pressure plasmas have been used in a variety of material processing
The anterior approach for a non-image-guided intra-articular hip injection.
Mei-Dan, Omer; McConkey, Mark O; Petersen, Brian; McCarty, Eric; Moreira, Brett; Young, David A
2013-06-01
The purpose of this study was to investigate and validate the accuracy and safety of a technique using an anterior approach for non-image-guided intra-articular injection of the hip by use of anatomic landmarks. We enrolled 55 patients. Injections were performed before supine hip arthroscopy after landmarking and before application of traction. After the needle insertion, success was confirmed with an air arthrogram and by direct visualization after arthroscope insertion. Accuracy and difficulty achieving correct needle placement were correlated with age, weight, height, body mass index, body type, gender, and surgical indication, as well as femoral and pelvic morphology. Forty-five patients who underwent injection in the office were followed up separately to document injection side effects. Needle placement accuracy was correlated to patients' demographics. All statistical tests with P values were 2 sided, with the level of significance set at P < .05. There were 51 correct needle placements and 4 misses, yielding a 93% success rate. The most common location for needle placement was the upper medial head-neck junction. Female gender was correlated with a more difficult needle placement and misses in relation to group size (P = .06). The reasons for misplacements of the needle were a high-riding trochanter, increased femoral version, thick adipose tissue over the landmarks, and variant of ilium morphology. Of 45 patients in the side effect study arm, 3 reported sensory changes of the lateral femoral cutaneous nerve that resolved within 24 hours. Hip injections by use of the direct anterior approach, from the intersection of the lines drawn from the anterior superior iliac spine and 1 cm distal to the tip of the greater trochanter, are safe and reproducible. Patient characteristics, such as increased subcutaneous adipose tissue or osseous anatomic variants, can lead to difficulty in placing the needle successfully. These characteristics can be predicted with the aid of physical examination and careful study of the pelvic radiographs. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kyrish, Matthew; Dobbs, Jessica; Richards-Kortum, Rebecca; Tkaczyk, Tomasz
2013-03-01
In order to diagnose cancer in breast tissue, a sample must be removed, prepared, and examined under a microscope. To provide an alternative to conventional biopsies, an endomicroscope intended to perform optical biopsies is demonstrated. The system provides high resolution, high contrast images in real-time which could allow a diagnosis to be made during surgery without the need for tissue removal. Optical sectioning is achieved via structured illumination to reject out of focus light. An image is relayed between the sample plane and the imaging system by a coherent fiber bundle with an achromatized objective lens at the distal tip of the fiber bundle which is the diameter of a biopsy needle. The custom, plastic objective provides correction for both the excitation and emission wavelengths of proflavine (452 nm and 515 nm, respectively). It also magnifies the object onto the distal tip of the fiber bundle to increase lateral resolution. The lenses are composed of the optical plastics Zeonex E48R, PMMA, and polystyrene. The lenses are fabricated via single point diamond turning and assembled using a zero alignment technique. The lateral resolution and chromatic focal shift were measured and in vitro images of breast carcinoma cells stained with proflavine were captured. The optical biopsy system is able to achieve optical sectioning and to resolve smaller features than the current high resolution microendoscope.
Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.
Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G
2013-04-01
This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.
SMART micro-scissors with dual motors and OCT sensors (Conference Presentation)
NASA Astrophysics Data System (ADS)
Yeo, Chaebeom; Jang, Seonjin; Park, Hyun-cheol; Gehlbach, Peter L.; Song, Cheol
2017-02-01
Various end-effectors of microsurgical instruments have been developed and studied. Also, many approaches to stabilize the tool-tip using robotics have been studied such as the steady hand robot system, Micron, and SMART system. In our previous study, the horizontal SMART micro-scissors with a common path swept source OCT distance and one linear piezoelectric (PZT) motor was demonstrated as a microsurgical system. Because the outer needle is connected with a mechanical handle and moved to engage the tool tip manually, the tool tip position is instantaneously changed during the engaging. The undesirable motion can make unexpected tissue damages and low surgical accuracy. In this study, we suggest a prototype horizontal SMART micro-scissors which has dual OCT sensors and two motors to improve the tremor cancellation. Dual OCT sensors provide two distance information. Front OCT sensor detects a distance from the sample surface to the tool tip. Rear OCT sensors gives current PZT motor movement, acting like a motor encoder. The PZT motor can compensate the hand tremor with a feedback loop control. The manual engaging of tool tip in previous SMART system is replaced by electrical engaging using a squiggle motor. Compared with previous study, this study showed better performance in the hand tremor reduction. From the result, the SMART with automatic engaging may become increasingly valuable in microsurgical instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kew, Jacqueline; Davies, Roger P.
2004-01-15
A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less
3D PIC-MCC simulations of positive streamers in air gaps
NASA Astrophysics Data System (ADS)
Jiang, M.; Li, Y.; Wang, H.; Liu, C.
2017-10-01
Simulation of positive streamer evolution is important for understanding the microscopic physical process in discharges. Simulations described in this paper are done using a 3D Particle-In-Cell, Monte-Carlo-Collision code with photoionization. Three phases of a positive streamer evolution, identified as initiation, propagation, and branching are studied during simulations. A homogeneous electric field is applied between parallel-flat electrodes forming a millimeter air gap to make simulations and analysis more simple and general. Free electrons created by the photoionization process determine initiation, propagation, and branching of the streamers. Electron avalanches form a positive streamer tip, when the space charge of ions at the positive tip dominates the local electric field. The propagation of the positive tip toward a cathode is the result of combinations of the positive tip and secondary avalanches ahead of it. A curved feather-like channel is formed without obvious branches when the electric field between electrodes is 50 kV/cm. However, a channel is formed with obvious branches when the electric field increases up to 60 kV/cm. In contrast to the branches around a sharp needle electrode, branches near the flat anode are formed at a certain distance away from it. Simulated parameters of the streamer such as diameter, maximum electric field, propagation velocity, and electron density at the streamer tip are in a good agreement with those published earlier.
Autonomous surgical robotics using 3-D ultrasound guidance: feasibility study.
Whitman, John; Fronheiser, Matthew P; Ivancevich, Nikolas M; Smith, Stephen W
2007-10-01
The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.
Šantak, Vedran; Zaplotnik, Rok; Tarle, Zrinka; Milošević, Slobodan
2015-11-01
Optical emission spectroscopy was performed during atmospheric pressure plasma needle helium jet treatment of various tooth-bleaching gels. When the gel sample was inserted under the plasma plume, the intensity of all the spectral features increased approximately two times near the plasma needle tip and up to two orders of magnitude near the sample surface. The color change of the hydroxylapatite pastille treated with bleaching gels in conjunction with the atmospheric pressure plasma jet was found to be in correlation with the intensity of OH emission band (309 nm). Using argon as an additive to helium flow (2 L/min), a linear increase (up to four times) of OH intensity and, consequently, whitening (up to 10%) of the pastilles was achieved. An atmospheric pressure plasma jet activates bleaching gel, accelerates OH production, and accelerates tooth bleaching (up to six times faster).
Temporary quadriplegia following continuous thoracic paravertebral block.
Calenda, Emile; Baste, Jean Marc; Danielou, Eric; Michelin, Paul
2012-05-01
A case of temporary quadriplegia following a continuous thoracic paravertebral block in an adult patient scheduled for video-assisted thoracoscopy is presented. An 18-gauge Tuohy needle was inserted under direct vision by the surgeon but the tip of the catheter was not localized. Postoperatively, the patient developed temporary quadriplegia 90 minutes after the start of a continuous infusion of ropivacaine 0.2%. Imaging studies showed that the catheter was localized in the intrathecal space. Copyright © 2012 Elsevier Inc. All rights reserved.
Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An
2015-12-01
TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.
Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade.
Fredrickson, Michael J; Ball, Craig M; Dalgleish, Adam J
2011-01-01
We investigated perineural catheter threading distance and orifice configuration during continuous interscalene analgesia. One hundred fifty-three patients receiving an anterolateral interscalene catheter (catheter needle and nerve/plexus in a similar alignment) for elective shoulder surgery were randomized to 1 of 3 groups: following out-of-plane ultrasound confirmation of the needle tip immediately lateral to the C5/6 roots, a nonstimulating catheter was blindly advanced 0.5 cm (end-hole; n = 50), 2.5 cm (multiorifice; n = 50) or 5 cm (multiorifice; n = 53) beyond the needle tip. Ropivacaine 0.75% + lidocaine 1% (50:50) 20 mL was administered preoperatively via the catheter before surgery under general anesthesia. A ropivacaine 0.2% 2 mL/hr elastomeric infusion with mandatory 6 hourly (and on demand) 5-mL boluses was continued for more than 48 hrs with tramadol available as rescue. Patients were questioned in the recovery room, at 24 and 48 hrs for numerical rating pain score (0-10), ropivacaine bolus, and tramadol consumption. Patients were more frequently pain-free in the recovery room in the multiorifice 2.5 and 5 cm groups compared with the end-hole 0.5 cm group (94%, 91% vs 66%; P < 0.001). During the first 24 hrs, the end-hole group demonstrated an earlier time to first pain (median, 10 vs17, 15 hrs; P < 0.001), higher "average pain" (median, 3 vs 1, 2, P = 0.004), and more ropivacaine bolus (median, 5 vs 3, 3; P < 0.001) and tramadol consumption (P = 0.01). Groups 2.5 and 5 cm did not significantly differ in any outcomes. These results suggest that multiorifice catheters provide superior intermittent bolus continuous peripheral nerve blockade compared with end-hole catheters. For anterolateral approach interscalene catheter placement, there is minimal benefit, either way, to 2.5- or 5-cm blind catheter advancement.
Stoltz, Petronella; Manworren, Renee C B
Needle procedures, like venipuncture and intravenous (IV) catheter insertion, are recognized as a common cause of pain and fear for children in hospitals and emergency departments. The purpose of this study was to compare children's self-reported pain and fear related to IV insertion with administration of either the topical local anesthetic EMLA® or 1% buffered lidocaine delivered with the J-Tip Needleless Injection System® (J-Tip®). In this prospective, randomized trial, 150 consecutive pediatric patients 8 to 18years of age undergoing IV insertion were randomly assigned 1:1 to treatment group. Participants self-reported procedural pain using a Visual Analog Scale, and procedural fear using the Children's Fear Scale. Procedural pain scores were significantly lower in the EMLA® group (mean score 1.63+1.659) vs. the J-Tip® group (2.99±2.586; p<0.001). Post-procedure fear scores were significantly lower than pre-procedure fear scores in both treatment groups (p<0.002), but there was no difference in fear scores between the two treatment groups (p=0.314). EMLA® provided superior pain relief for IV insertion compared to J-Tip®. Although EMLA® use resulted in lower self-reported pain scores compared to J-Tip®, pain scores for both treatments were low and fear scores did not differ. When IV insertion can be delayed for 60-90min, EMLA® should be used. When a delay is contraindicated, J-Tip® may be a reasonable alternative to minimize procedural pain of IV insertion. Copyright © 2017 Elsevier Inc. All rights reserved.
Furusho, Junji; Kobayashi, Hiroshi; Kikuchi, Takehito; Yamamoto, Tatsuro; Tanaka, Hidekazu; Terayama, Motokazu; Monden, Morito
2008-01-01
The purpose of this study is to realize the mechanically-controllable needle-insertion system using the CMTD (Curved Multi-Tube Device) which was developed by Furusho Laboratory. A CMTD, was developed for minimally-invasive surgery and needle insertion. And we use ultrasonograph as a sensing device to detect the position of bible duct or tumor and the orientation and position of the needle which is inserted into liver. This system makes safe minimally-invasive surgery possible, because all complex mechanisms are arranged outside of the body.
The fluid mechanics of root canal irrigation.
Gulabivala, K; Ng, Y-L; Gilbertson, M; Eames, I
2010-12-01
Root canal treatment is a common dental operation aimed at removing the contents of the geometrically complex canal chambers within teeth; its purpose is to remove diseased or infected tissue. The complex chamber is first enlarged and shaped by instruments to a size sufficient to deliver antibacterial fluids. These irrigants help to dissolve dying tissue, disinfect the canal walls and space and flush out debris. The effectiveness of the procedure is limited by access to the canal terminus. Endodontic research is focused on finding the instruments and clinical procedures that might improve success rates by more effectively reaching the apical anatomy. The individual factors affecting treatment outcome have not been unequivocally deciphered, partly because of the difficulty in isolating them and in making the link between simplified, general experimental models and the complex biological objects that are teeth. Explicitly considering the physical processes within the root canal can contribute to the resolution of these problems. The central problem is one of fluid motion in a confined geometry, which makes the dispersion and mixing of irrigant more difficult because of the absence of turbulence over much of the canal volume. The effects of treatments can be understood through the use of scale models, mathematical modelling and numerical computations. A particular concern in treatment is that caustic irrigant may penetrate beyond the root canal, causing chemical damage to the jawbone. In fact, a stagnation plane exists beyond the needle tip, which the irrigant cannot penetrate. The goal is therefore to shift the stagnation plane apically to be coincident with the canal terminus without extending beyond it. Needle design may solve some of the problems but the best design for irrigant penetration conflicts with that for optimal removal of the bacterial biofilm from the canal wall. Both irrigant penetration and biofilm removal may be improved through canal fluid agitation using a closely fitting instrument or by sonic or ultrasonic activation. This review highlights a way forward by understanding the physical processes involved through physical models, mathematical modelling and numerical computations.
New method to monitor RF safety in MRI-guided interventions based on RF induced image artefacts.
van den Bosch, Michiel R; Moerland, Marinus A; Lagendijk, Jan J W; Bartels, Lambertus W; van den Berg, Cornelis A T
2010-02-01
Serious tissue heating may occur at the tips of elongated metallic structures used in MRI-guided interventions, such as vascular guidewires, catheters, biopsy needles, and brachytherapy needles. This heating is due to resonating electromagnetic radiofrequency (RF) waves along the structure. Since it is hard to predict the exact length at which resonance occurs under in vivo conditions, there is a need for methods to monitor this resonance behavior. In this study, the authors propose a method based on the RF induced image artefacts and demonstrate its applicability in two phantom experiments. The authors developed an analytical model that describes the RF induced image artefacts as a function of the induced current in an elongated metallic structure placed parallel to the static magnetic field. It describes the total RF field as a sum of the RF fields produced by the transmit coil of the MR scanner and by the elongated metallic structure. Several spoiled gradient echo images with different nominal flip angle settings were acquired to map the B1+ field, which is a quantitative measure for the RF distortion around the structure. From this map, the current was extracted by fitting the analytical model. To investigate the sensitivity of our method we performed two phantom experiments with different setup parameters: One that mimics a brachytherapy needle insertion and one that resembles a guidewire intervention. In the first experiment, a short needle was placed centrally in the MR bore to ensure that the induced currents would be small. In the second experiment, a longer wire was placed in an off-center position to mimic a worst case scenario for the patient. In both experiments, a Luxtron (Santa Clara, CA) fiberoptic temperature sensor was positioned at the structure tip to record the temperature. In the first experiment, no significant temperature increases were measured, while the RF image artefacts and the induced currents in the needle increased with the applied insertion depth. The maximum induced current in the needle was 44 mA. Furthermore, a standing wave pattern became clearly visible for larger insertion depths. In the second experiment, significant temperature increases up to 2.4 degrees C in 1 min were recorded during the image acquisitions. The maximum current value was 1.4 A. In both experiments, a proper estimation of the current in the metallic structure could be made using our analytical model. The authors have developed a method to quantitatively determine the induced current in an elongated metallic structure from its RF distortion. This creates a powerful and sensitive method to investigate the resonant behavior of RF waves along elongated metallic structures used for MRI-guided interventions, for example, to monitor the RF safety or to inspect the influence of coating on the resonance length. Principally, it can be applied under in vivo conditions and for noncylindrical metallic structures such as hip implants by taking their geometry into account.
A thermal microprobe fabricated with wafer-stage processing
NASA Astrophysics Data System (ADS)
Zhang, Yongxia; Zhang, Yanwei; Blaser, Juliana; Sriram, T. S.; Enver, Ahsan; Marcus, R. B.
1998-05-01
A thermal microprobe has been designed and built for high resolution temperature sensing. The thermal sensor is a thin-film thermocouple junction at the tip of an atomic force microprobe (AFM) silicon probe needle. Only wafer-stage processing steps are used for the fabrication. For high resolution temperature sensing it is essential that the junction be confined to a short distance at the AFM tip. This confinement is achieved by a controlled photoresist coating process. Experiment prototypes have been made with an Au/Pd junction confined to within 0.5 μm of the tip, with the two metals separated elsewhere by a thin insulating oxide layer. Processing begins with double-polished, n-type, 4 in. diameter, 300-μm-thick silicon wafers. Atomically sharp probe tips are formed by a combination of dry and wet chemical etching, and oxidation sharpening. The metal layers are sputtering deposited and the cantilevers are released by a combination of KOH and dry etching. A resistively heated calibration device was made for temperature calibration of the thermal microprobe over the temperature range 25-110 °C. Over this range the thermal outputs of two microprobes are 4.5 and 5.6 μV/K and is linear. Thermal and topographical images are also obtained from a heated tungsten thin film fuse.
NASA Astrophysics Data System (ADS)
Alexandrov, Dmitri V.; Galenko, Peter K.; Toropova, Lyubov V.
2018-01-01
Motivated by important applications in materials science and geophysics, we consider the steady-state growth of anisotropic needle-like dendrites in undercooled binary mixtures with a forced convective flow. We analyse the stable mode of dendritic evolution in the case of small anisotropies of growth kinetics and surface energy for arbitrary Péclet numbers and n-fold symmetry of dendritic crystals. On the basis of solvability and stability theories, we formulate a selection criterion giving a stable combination between dendrite tip diameter and tip velocity. A set of nonlinear equations consisting of the solvability criterion and undercooling balance is solved analytically for the tip velocity V and tip diameter ρ of dendrites with n-fold symmetry in the absence of convective flow. The case of convective heat and mass transfer mechanisms in a binary mixture occurring as a result of intensive flows in the liquid phase is detailed. A selection criterion that describes such solidification conditions is derived. The theory under consideration comprises previously considered theoretical approaches and results as limiting cases. This article is part of the theme issue `From atomistic interfaces to dendritic patterns'. This article is part of the theme issue `From atomistic interfaces to dendritic patterns'.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needlemore » angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate errors in needle positioning and improve the dose distribution. Without re-optimization, target coverage and OAR constraints may not be achieved. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are full-time employees of Philips Medical Systems Nederland B.V.« less
Determining the acoustic properties of the lens using a high-frequency ultrasonic needle transducer.
Huang, Chih-Chung; Zhou, Qifa; Ameri, Hossein; Wu, Da Wei; Sun, Lei; Wang, Shyh-Hau; Humayun, Mark S; Shung, K Kirk
2007-12-01
Ultrasonic parameters including sound velocity and attenuation coefficient have recently been found to be useful in characterizing the cataract lens noninvasively. However, the regional changes of these acoustic parameters in the lens cannot be detected directly by those ultrasonic measurements. This prompted us to fabricate a 46-MHz needle transducer (lead magnesium niobate-lead titanate [PMN-PT] single crystal) with an aperture size of 0.4 mm and a diameter of 0.9 mm for directly measuring the sound velocity and frequency-dependent attenuation coefficient in lenses. These parameters have been shown to be related to the hardness of a cataract, and hence this technique may allow surgeons to detect the acoustic properties of the cataract via a small incision on the cornea before/during phacoemulsification surgery. To verify the performance of the needle transducer, experiments were performed on porcine lenses in which two types of cataracts (nucleus and cortical) were induced artificially. The needle transducer was mounted on a positioning system and its tip was inserted into the lens, allowing the anterior-to-posterior profiles of acoustic parameters along the lens axis to be obtained immediately. The experimental results show that the acoustic parameters are not constant within a single normal lens. The sound velocity and ultrasound attenuation coefficient (at 46 MHz) were 1701.2 +/- 8.4 m/s (mean +/- SD) and 9.42 +/- 0.57 dB/mm, respectively, at the nucleus, and 1597.2 +/- 9.6, 1589.3 +/- 6.1 m/s and 0.42 +/- 0.26 and 0.40 +/- 0.33 dB/mm close to the anterior and posterior capsules, respectively. Finally, the data obtained demonstrate that regional variations in the acoustic properties of lenses corresponding to the hardness of different types of cataract can be detected sensitively by a needle transducer.
Guérin, Marceau; Martin-Benito, Dario; von Arx, Georg; Andreu-Hayles, Laia; Griffin, Kevin L; Hamdan, Rayann; McDowell, Nate G; Muscarella, Robert; Pockman, William; Gentine, Pierre
2018-02-01
In the southwestern USA, recent large-scale die-offs of conifers raise the question of their resilience and mortality under droughts. To date, little is known about the interannual structural response to droughts. We hypothesized that piñon pines ( Pinus edulis ) respond to drought by reducing the drop of leaf water potential in branches from year to year through needle morphological adjustments. We tested our hypothesis using a 7-year experiment in central New Mexico with three watering treatments (irrigated, normal, and rain exclusion). We analyzed how variation in "evaporative structure" (needle length, stomatal diameter, stomatal density, stomatal conductance) responded to watering treatment and interannual climate variability. We further analyzed annual functional adjustments by comparing yearly addition of needle area (LA) with yearly addition of sapwood area (SA) and distance to tip ( d ), defining the yearly ratios SA:LA and SA:LA/ d . Needle length ( l ) increased with increasing winter and monsoon water supply, and showed more interannual variability when the soil was drier. Stomatal density increased with dryness, while stomatal diameter was reduced. As a result, anatomical maximal stomatal conductance was relatively invariant across treatments. SA:LA and SA:LA/ d showed significant differences across treatments and contrary to our expectation were lower with reduced water input. Within average precipitation ranges, the response of these ratios to soil moisture was similar across treatments. However, when extreme soil drought was combined with high VPD, needle length, SA:LA and SA:LA/ d became highly nonlinear, emphasizing the existence of a response threshold of combined high VPD and dry soil conditions. In new branch tissues, the response of annual functional ratios to water stress was immediate (same year) and does not attempt to reduce the drop of water potential. We suggest that unfavorable evaporative structural response to drought is compensated by dynamic stomatal control to maximize photosynthesis rates.
A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.
Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M
To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Elemental and Isotopic Tomography at Single-Atom-Scale in 4.0 and 2.4 Ga Zircons
NASA Astrophysics Data System (ADS)
Valley, J. W.; Reinhard, D. A.; Snoeyenbos, D.; Lawrence, D.; Martin, I.; Kelly, T. F.; Ushikubo, T.; Strickland, A.; Cavosie, A. J.
2012-12-01
Atom probe tomography can determine identity (mass/charge ratio) and 3-D position of individual atoms in minerals such as zircon. These data provide unique information for understanding the thermal history and mechanisms of mineral reaction and exchange, including radiation damage. Nine needle-shaped specimens ~100 nm in diameter (at the apex) were sampled from 2 zircons by FIB and analyzed with a local-electrode atom probe (LEAP), CAMECA LEAP 4000X HR. The LEAP uses pulsed-laser heating to field evaporate the tip of a zircon needle and accelerates the ions into a position-sensitive TOF-MS. With due care for complex isobaric interferences (molecules, multiple ionizations) and background correction, it is possible to individually identify up to 10E8 atoms/needle (36% detection efficiency) by mass/charge (MRP ~ 1000@ m/n=16Da) and position (X-Y-Z coordinates on 0.2 nm scale) (Kelly & Larson 2012). The 3-D distribution of Pb and Y differ at atom-scale in the 2 zircons. Zircon #1 (4007 Ma, Jack Hills, W. Australia, Cavosie 2005, Ushikubo et al. 2008, Bouvier et al. 2011) is homogeneous in Pb and Y. In contrast, incompatible elements, including Pb and Y, are concentrated in equant 5-10 nm dia. domains, spaced ~50 nm apart in zircon #2 (2438 Ma, Albion-Raft R-Grouse Ck core complex, Utah, Strickland et al. 2011). U is homogeneously distributed in both zircons. The analyzed domains suffered 4-8 x 10E15 α-decay events/mg due to U and Th decay and yet both zircons yield >97% concordant U-Pb ages by SIMS, suggesting annealing of radiation damage during the life of the zircons. The 207-Pb/206-Pb ratios for these nm-scale domains, as measured by LEAP, average 0.17 for the 2.4 Ga Zrc2 (3 needles) and 0.43 for the 4.0 Ga Zrc1 (5 needles). These ratios are less precise (±40% 2σ) due to ultra-small sample size, but are in excellent agreement with values measured by SIMS, 0.1684 and 0.4269, respectively. Thus Pb in both zircons is radiogenic. The Pb-Y-rich domains and lack of correlation with U in Zrc2 is best explained by diffusion of Pb and other incompatible elements (Y, REEs) into 5-10 nm domains that were damaged by α-recoil and may have been metamict as the result of single U- or Th-decay chains. Diffusion distances of ~20 nm for these elements in crystalline zircon require temperatures above 700 C for ~10 myrs (Cherniak 2010). This is consistent with the known history of Zrc2, as a xenocrystic 2.4 Ga zircon in a 29 Ma granodiorite phase of a long-lived, extension-related plutonic suite that experienced high-grade regional metamorphism. In contrast, the absence of enriched domains in Zrc1 suggests that this zircon did not experience similar high-grade metamorphism before or after its deposition within the ~3 Ga Jack Hills metaconglomerate.
Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.
Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R
2008-12-01
Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.
Novel Magnetic Resonance Detection and Profiling of Ovarian Cancer Across Specimens
2012-10-01
Cancer Cells in Fine - Needle Aspirates. Proc. Natl. Acad. Sci. U.S.A. 2009, 106, 12459–12464. 25. Han,H. S.; Devaraj,N. K.; Lee, J.; Hilderbrand, S.A... fine needle aspirates, biopsies, ascites, blood, sputum), which are inherently complex in composition, as well as heterogeneous and variable in cell...in ascitic fluid, we anticipate that this method could similarly be applied to fine needle aspirates, blood, biopsy spec- imens, sputum, and other
Metabolomic profiling of anionic metabolites by capillary electrophoresis mass spectrometry.
Soga, Tomoyoshi; Igarashi, Kaori; Ito, Chiharu; Mizobuchi, Katsuo; Zimmermann, Hans-Peter; Tomita, Masaru
2009-08-01
We describe a sheath flow capillary electrophoresis time-of-flight mass spectrometry (CE-TOFMS) method in the negative mode using a platinum electrospray ionization (ESI) spray needle, which allows the comprehensive analysis of anionic metabolites. The material of the spray needle had significant effect on the measurement of anions. A stainless steel spray needle was oxidized and corroded at the anodic electrode due to electrolysis. The precipitation of iron oxides (rust) plugged the capillary outlet, resulting in shortened capillary lifetime. Many anionic metabolites also formed complexes with the iron oxides or migrating nickel ion, which was also generated by electrolysis and moved toward the cathode (the capillary inlet). The metal-anion complex formation significantly reduced detection sensitivity of the anionic compounds. The use of a platinum ESI needle prevented both oxidation of the metals and needle corrosion. Sensitivity using the platinum needle increased from several- to 63-fold, with the largest improvements for anions exhibiting high metal chelating properties such as carboxylic acids, nucleotides, and coenzyme A compounds. The detection limits for most anions were between 0.03 and 0.87 micromol/L (0.8 and 24 fmol) at a signal-to-noise ratio of 3. This method is quantitative, sensitive, and robust, and its utility was demonstrated by the analysis of the metabolites in the central metabolic pathways extracted from mouse liver.
Usefulness of IT knife nano for endoscopic submucosal dissection of large colo-rectal lesions.
Suzuki, T; Hara, T; Kitagawa, Y; Yamaguchi, T
2016-01-01
Endoscopic submucosal dissection (ESD) is currently widely conducted for the treatment of early gastrointestinal -cancers. Due to the characteristic anatomy of the large intestine, needle- tip type devices such as Dual knife are mainly used in colorectal ESD. On the other hand, the non- needle-tip type IT knife is a unique device with an insulated tip, and has been reported to be safe, efficacious and speedy when used in gastric ESD. A new model of IT knife, IT knife nano, anticipated to be useful for esophageal and colorectal ESD has become available, but its usefulness has not been reported. Therefore, we performed this study to evaluate the usefulness of IT knife nano for ESD of large colorectal lesions. Previous studies have shown that a tumor size of 40 mm or above significantly prolongs treatment time and is a factor of treatment difficulty. We selected colorectal lesions of 40 mm and above, and compared 32 lesions treated with Dual knife alone before IT knife nano was available (No-IT group) and 40 cases treated with IT knife nano as a second knife after IT knife nano became available (IT group). We assessed en bloc resection rate, complete en bloc resection rate, complication rate and treatment time. The en bloc resection rates in No-IT group and IT group were 100% and 97.5%, respectively, with no significant difference. The respective median treatment time was 70 min and 51 min, and was significantly shortened in IT group (P < 0.05). The respective rates of procedure- related perforation were 3.1% and 0% ; in IT group suggesting a tendency of reduced incidence. Use of IT knife nano in ESD for large colorectal -lesions achieves the same levels of efficacy and safety as conventional device, with the additional merit of shortening treatment time. © Acta Gastro-Enterologica Belgica.
Atraumatic versus traumatic lumbar puncture needles: a systematic review and meta-analysis protocol
Nath, Siddharth; Badhiwala, Jetan H; Alhazzani, Waleed; Nassiri, Farshad; Belley-Cote, Emilie; Koziarz, Alex; Shoamanesh, Ashkan; Banfield, Laura; Oczkowski, Wieslaw; Sharma, Mike; Sahlas, Demetrios; Reddy, Kesava; Farrokhyar, Forough; Singh, Sheila; Sharma, Sunjay; Zytaruk, Nicole; Selim, Magdy; Almenawer, Saleh A
2017-01-01
Introduction Lumbar puncture is one of the oldest and most commonly performed procedures in medicine, used to diagnose and treat disease. Headache following lumbar puncture remains a frequent complication, causing significant patient discomfort and often requiring narcotic analgesia or invasive therapy. Needle tip design has been proposed to affect the incidence of headache postlumbar puncture, with pencil-point ‘atraumatic’ needles thought to reduce its incidence in comparison to bevelled ‘traumatic’ needles. Despite this, the use of atraumatic needles and knowledge of their existence remains significantly limited among clinicians. This study will systematically review the evidence on atraumatic lumbar puncture needles and compare them with traumatic needles across a variety of clinical outcomes. Methods and analyses We will include published randomised controlled trials (RCTs), observational studies and abstracts, with no publication type or language restrictions. Search strategies will be designed to peruse the MEDLINE, EMBASE, Web of Science, ClinicalTrials.gov, CINAHL, WHO Clinical Trials Database and Cochrane Library databases. We will also implement strategies to search the grey literature. 3 reviewers will thoroughly and independently examine the search results, complete data abstraction and conduct quality assessment. Included RCTs will be assessed using the Cochrane risk of bias assessment tool and eligible observational studies will be examined using the Newcastle-Ottawa Scale. We will examine the outcomes of: headache and its type, intensity, duration and treatment; backache; success rate; hearing disturbance and nerve root irritation. The primary outcome will be the incidence of postdural puncture headache. We will calculate pooled estimates, relative risks for dichotomous outcomes and weighted mean differences for continuous outcomes, with corresponding 95% CIs. Statistical heterogeneity will be measured using Cochran's Q test and quantified using the I2 statistic. We will also conduct prespecified subgroup and sensitivity analyses to examine if covariates exist and to explore potential heterogeneity. Ethics and dissemination Research ethics board approval is not required for this study as it draws from published data and raises no concerns related to patient privacy. This review will provide a comprehensive assessment of the evidence on atraumatic needles for lumbar puncture and is directed to a wide audience. Results from the review will be disseminated extensively through conferences and submitted to a peer-reviewed journal for publication. Trial registration number CRD42016047546. PMID:28363928
2014-01-01
Deprotonation of [U(TrenTIPS)(NH2)] (1) [TrenTIPS = N(CH2CH2NSiPri3)3] with organoalkali metal reagents MR (M = Li, R = But; M = Na–Cs, R = CH2C6H5) afforded the imido-bridged dimers [{U(TrenTIPS)(μ-N[H]M)}2] [M = Li–Cs (2a–e)]. Treatment of 2c (M = K) with 2 equiv of 15-crown-5 ether (15C5) afforded the uranium terminal parent imido complex [U(TrenTIPS)(NH)][K(15C5)2] (3c), which can also be viewed as a masked uranium(IV) nitride. The uranium–imido linkage was found to be essentially linear, and theoretical calculations suggested σ2π4 polarized U–N multiple bonding. Attempts to oxidize 3c to afford the neutral uranium terminal parent imido complex [U(TrenTIPS)(NH)] (4) resulted in spontaneous disproportionation to give 1 and the uranium–nitride complex [U(TrenTIPS)(N)] (5); this reaction is a new way to prepare the terminal uranium–nitride linkage and was calculated to be exothermic by −3.25 kcal mol–1. PMID:24697157
Adiabatic description of superfocusing of femtosecond plasmon polaritons
NASA Astrophysics Data System (ADS)
Golovinski, P. A.; Manuylovich, E. S.; Astapenko, V. A.
2018-05-01
A surface plasmon polariton is a collective oscillation of free electrons at a metal-dielectric interface. As wave phenomena, surface plasmon polaritons can be focused with the use of an appropriate excitation geometry of metal structures. In the adiabatic approximation, we demonstrate a possibility to control nanoscale short pulse superfocusing based on generation of a radially polarized surface plasmon polariton mode of a conical metal needle in view of wave reflection. The results of numerical simulations of femtosecond pulse propagation along a nanoneedle are discussed. The space-time evolution of a pulse for the near field strongly depends on a linear chirp of an initial laser pulse, which can partially compensate wave dispersion. The field distribution is calculated for different metals, chirp parameters, cone opening angles and propagation distances. The electric field near a sharp tip is described as a field of a fictitious time-dependent electric dipole located at the tip apex.
Miniature fibre optic probe for minimally invasive photoacoustic sensing
NASA Astrophysics Data System (ADS)
Mathews, Sunish J.; Zhang, Edward Z.; Desjardins, Adrien E.; Beard, Paul C.
2016-03-01
A miniature (175 μm) all-optical photoacoustic probe has been developed for minimally invasive sensing and imaging applications. The probe comprises a single optical fibre which delivers the excitation light and a broadband 50 MHz Fabry-Pérot (F-P) ultrasound sensor at the distal end for detecting the photoacoustic waves. A graded index lens proximal to the F-P sensor is used to reduce beam walk-off and thus increase sensitivity as well as confine the excitation beam in order to increase lateral spatial resolution. The probe was evaluated in non-scattering media and found to provide lateral and axial resolutions of < 100 μm and < 150 μm respectively for distances up to 1 cm from the tip of the probe. The ability of the probe to detect a blood vessel mimicking phantom at distances up to 7 mm from the tip was demonstrated in order to illustrate its potential suitability for needle guidance applications.
Sang, Hongqiang; Yang, Chenghao; Liu, Fen; Yun, Jintian; Jin, Guoguang; Chen, Fa
2016-12-01
Hand physiological tremor of surgeons can cause vibration at the surgical instrument tip, which may make it difficult for the surgeon to perform fine manipulations of tissue, needles, and sutures. A zero phase adaptive fuzzy Kalman filter (ZPAFKF) is proposed to suppress hand tremor and vibration of a robotic surgical system. The involuntary motion can be reduced by adding a compensating signal that has the same magnitude and frequency but opposite phase with the tremor signal. Simulations and experiments using different filters were performed. Results show that the proposed filter can avoid the loss of useful motion information and time delay, and better suppress minor and varying tremor. The ZPAFKF can provide less error, preferred accuracy, better tremor estimation, and more desirable compensation performance, to suppress hand tremor and decrease vibration at the surgical instrument tip. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Endoscopic submucosal dissection using flexknife.
Kodashima, Shinya; Fujishiro, Mitsuhiro; Yahagi, Naohisa; Kakushima, Naomi; Omata, Masao
2006-01-01
Although the standard treatment for early-stage gastrointestinal tumors is still surgical resection, endoscopic resection has been accepted for some of these lesions, especially in Japan. However, the indication was limited until recently to achieve en bloc resection and prevent local recurrence. To overcome the disadvantage of endoscopic resection with conventional endoscopic mucosal resection (EMR), several investigators, including us, have developed a new endoscopic resection technique: endoscopic submucosal dissection (ESD). ESD is a remarkable technique that enables to remove the lesions en bloc regardless of size, shape, coexisting ulcer, and location. Nowadays, several knives are available for ESD, such as the needle knife, insulation-tipped (IT) knife, Hookknife, triangle-tipped (TT) knife, and Flexknife. Each of them has some merits and demerits, and the ways to use the knives are different. We summarize here how to use the Flexknife, which we made ourselves in cooperation with the Olympus Company, and how we use the technique in our hospital.
Atom Probe Tomography of Geomaterials
NASA Astrophysics Data System (ADS)
Parman, S. W.; Diercks, D.; Gorman, B.; Cooper, R. F.
2013-12-01
From the electron microprobe to the secondary ion microprobe to laser-ablation ICP-MS, steady improvements in the spatial resolution and detection limits of geochemical micro-analysis have been central to generating new discoveries. Atom probe tomography (APT) is a relatively new technology that promises nm-scale spatial resolution (in three dimensions) with ppm level detection limits. The method is substantially different from traditional beam-based (electron, ion, laser) methods. In APT, the sample is shaped (usually with a dual-beam FIB) into a needle with typical dimensions of 1-2 μm height and 100-200 nm diameter. Within the atom probe, the needle is evaporated one atom (ideally) at a time by a high electric field (ten's of V per square nm at the needle tip). A femtosecond laser (12 ps pulse width) is used to assist in evaporating non-conducting samples. The two-dimensional detector locates where the atom was released from the needle's surface and so can reconstruct the positions of all detected atoms in three dimensions. It also records the time of flight of the ion, which is used to calculate the mass/charge ratio of the ion. We will discuss our results analyzing a range of geologic materials. In one case, naturally occurring platinum group alloys (PGA) from the Josephine Ophiolite have been imaged. Such alloys are of interest as recorders of the Os heterogeneity of the mantle [1,2]. Optimal ablation was achieved with a laser power of 120-240 pJ and laser pulse rates 500 kHz. Runs were stopped after 10 million atoms were imaged. An example analysis is: Pt 61(1), Fe 26.1(9), Rh 1.20(4), Ir 7.0(7), Ni 2.65(8), Ru 0.20(9), Cu 1.22(8), Co 0.00029(5). Values are in atomic %; values in parentheses are one-sigma standard deviations on five separate needles from the same FIB lift-out, which was 30 μm long. Assuming the sample is homogenous over the 30 μm from which the needle was extracted, the analyses suggest relative errors for major elements below 5% and for trace elements (100ppm level) below 20%. The images of the PGA grains have sub-nm spatial resolution, remarkably showing clear atomic planes of the hexoctahedral structure. Conducting materials such as the PGA grains are ideal materials for APT analysis. Silicates present a much more challenging target due to their electrical resistance and strong metal-oxygen bonds. The oxide bonds are difficult to break, resulting in ablation of oxide molecules with various charge states. These cause multiple interferences for many major elements of interest such as Si, Fe, Mg and Ca. We have imaged a range of olivine compositions (Fo0 to Fo90). Due to its higher electrical conductivity, fayalite evaporates at lower field voltages than more Mg-rich olivines. The spatial resolution is ~nm scale, so atomic planes are not resolvable. Chemical analyses are improved by low laser energies (<0.1pJ) at laser pulse rates of 500 kHz, as well as by large tip radii, which improves heat diffusion out of the needle. [1] Pearson et al 2007 Nature 449: 202-205 [2] Luguet et al 2008 Science 319: 453-456
Chen, Dan; Xie, Qiange; Huang, Bing-Lin
2014-01-01
Professor XIE Qiang's Tihu Guanding needling method, a kind of acupuncture method which takes acupoints of the Conception Vessel as the primary and acupoints of the Governor Vessel as the secondary. Acupoints Lianquan (CV 23), Tiantu (CV 22), Qihai (CV 6), Zhongwan (CV 12), Baihui (GV 20) and Dazhui (GV 14) are adopted as the basic ones. Other points can be added according to various symptoms, for instance, Yingxiang (LI 20) and Yintang (GV 29) for rhinopathy, Tinggong (SI 19) and Yifeng (TE 17) for otopathy, Yan'an (Professor XIE's experience) and Shanglianquan (EX-HN 21) for pharyngopathy and Kaiyin 1 (Professor XIE's experience) and Kaiyin 2 (Professor XIE's experience) for laryngopathy. During the needle retention, rotation manipulation should be done every 5 min at Lianquan (CV 23). And the patient should be told to put the tip of one's tongue at the the palate as well as to do deep breathing to communicate the Conception Vessel and the Governor Vessel. Moxibustion is adopted at Yongquan (KI 1) to induce the up floating fire to mingmen (where the primary yang is stored). The therapeutic effect on treatment of persistent otorhinolaryngologic diseases with the above mentioned method is approve to be good.
NASA Astrophysics Data System (ADS)
Li, Xuechen; Niu, Dongying; Jia, Pengying; Zhao, Na; Yuan, Ning
2011-04-01
In this study, a dielectric barrier discharge device with needle-plate electrodes was used to investigate the characteristics of the micro-discharge in argon at one atmospheric pressure by an optical method. The results show that there are two discharge modes in the dielectric barrier discharge, namely corona mode and filamentary mode. The corona discharge only occurs in the vicinity of the needle tip when the applied voltage is very low. However, the filamentary discharge mode can occur, and micro-discharge bridges the two electrodes when the applied voltage reaches a certain value. The extended area of micro-discharge on the dielectric plate becomes larger with the increase in applied voltage or decrease in gas pressure. The variance of the light emission waveforms is studied as a function of the applied voltage. Results show that very narrow discharge pulse only appears at the negative half cycle of the applied voltage in the corona discharge mode. However, broad hump (about several microseconds) can be discerned at both the negative half cycle and the positive half cycle for a high voltage in the filamentary mode. Furthermore, the inception voltage decreases and the width of the discharge hump increases with the increase in applied voltage. These experimental phenomena can be explained qualitatively by analyzing the discharge mechanism.
Gay, Don D.
1986-01-01
A gas ampoule for the shipment and delivery of radioactive gases. The gas ampoule having a glass tube with serum bottle stopper on one end and a plunger tip in the opposite end all fitting in a larger plastic tube threaded on each end with absorbent between the tubes, is seated onto the internal needle assembly via a bushing associated with the plunger and locked into the syringe barrel via barrel-bushing locking caps. The design practically eliminates the possibility of personnel contamination due to an inadvertent exposure of such personnel to the contained radioactive gas.
Gay, D.D.
1985-02-02
A gas ampoule for the shipment and delivery of radioactive gases. The gas ampoule having a glass tube with serum bottle stopper on one and a plunger tip in the opposite end all fitting in a larger plastic tube threaded on each end with absorbent between the tubes, is seated onto the internal needle assembly via a bushing associated with the plunger and locked into the syringe barrel via barrel-bushing locking caps. The design practically eliminates the possibility of personnel contamination due to an inadvertent exposure of such personnel to the contained radioactive gas.
Numerical investigation of self-sustained oscillations in the flow over the spiked blunt body
NASA Astrophysics Data System (ADS)
Konstantin, Babarykin
2018-05-01
Numerical simulation of the supersonic turbulent flow around spike-tipped cylindrical body is carried out. The self-sustained oscillating flow picture is studied. For the simulations the ANSYS Fluent finite-volume solver is employed, the calculations are performed mainly for 2d axisymmetric case, and some simulations are made in 3d version. The freestream Mach number is 2,22, the cases of sharp and obtuse needle of different length are considered. The numerical results are obtained using different turbulence models, are compared with experimental data.
1999-04-01
atrium , the inferior vena cava was closed with a silk ligature and the liver was carefully excised. 2.4 Liver...withdraw needle. 5.5.10 Secure tip of cannula with ligature and connect medium at lowest flow rate (5 mL/min). 5.5.11 Cut inferior vena cava below the...heart. 5.5.14 Cannulate the superior vena cava via an incision in the right atrium , secure with ligature. 5.5.15 Close ligature around inferior vena cava
Percutaneous needling of Morton’s complex: a technical note
Atilano, Leire; Martin, Jose Ignacio; Iglesias, Gotzon; Andia, Isabel
2015-01-01
Summary Background the Morton’s complex, i.e. fibrotic mass enfolding the medial plantar nerve, the bursa and the interdigital transverse ligament in the web space, is a common cause of pain and functional disability. Conservative and operative treatments are investigated but currently the best approach to treat the Morton’s complex is unknown. Methods we describe a non-invasive, straight forward intervention consisting on multiple percutaneous punctures, shearing the fibrotic tissue in lateromedial and anteroposterior directions. The goal is to break up fibrosis occupying the intermetatarsal space thus releasing the affected nerve from the adjacent structures, there by stimulating tissue remodelling. Results slow tissue remodelling occurs following sequential fibrosis cleavage through multiple needling. Needling of the intermetatarsal fibrosis is performed every eight weeks until pain resolution. Echographic changes are associated to pain reduction as measured by Visual Analogue Score (VAS). Conclusion we present an original idea that may improve Morton’s management. Upcoming prospective clinical studies have to demonstrate the symptomatic benefits and the usefulness of this novel echographic intervention. PMID:26958536
Dynamics of translational friction in needle-tissue interaction during needle insertion.
Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R
2014-01-01
In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.
Neptunium and plutonium complexes with a sterically encumbered triamidoamine (TREN) scaffold
Brown, Jessie L.; Gaunt, Andrew J.; King, David M.; ...
2016-03-11
Here, the syntheses and characterization of isostructural neptunium(IV) and plutonium(IV) complexes [M IV(TREN TIPS)(Cl)] [An = Np, Pu; TREN TIPS = {N(CH 2CH 2NSiPr i 3) 3} 3] are reported, along with the demonstration that they are likely reduced to the corresponding neptunium(III) and plutonium(III) products [M III(TREN TIPS)]; this chemistry provides new platforms from which to target a plethora of unprecedented molecular functionalities in transuranic chemistry and the neptunium(IV) molecule is the first structurally characterized neptunium(IV)–amide complex.
Simplified stereo-optical ultrasound plane calibration
NASA Astrophysics Data System (ADS)
Hoßbach, Martin; Noll, Matthias; Wesarg, Stefan
2013-03-01
Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing di erent calibration objects: a 6mm metal bar and a 1:25mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity. Ke
The optical "Veress-needle"--initial puncture with a minioptic.
Schaller, G; Kuenkel, M; Manegold, B C
1995-02-01
Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)
Özer, Senem; Yaltirik, Mehmet; Kirli, Irem; Yargic, Ilhan
2012-11-01
The aim of this study was to compare anxiety and pain levels during anesthesia and efficacy of Quicksleeper intraosseous (IO) injection system, which delivers computer-controlled IO anesthesia and conventional inferior alveolar nerve block (IANB) in impacted mandibular third molars. Forty subjects with bilateral impacted mandibular third molars randomly received IO injection or conventional IANB at 2 successive appointments. The subjects received 1.8 mL 2% articaine. IO injection has many advantages, such as enabling painless anesthesia with less soft tissue numbness and quick onset of anesthesia as well as lingual and palatal anesthesia with single needle penetration. Although IO injection is a useful technique commonly used during various treatments in dentistry, the duration of injection takes longer than conventional techniques, there is a possibility of obstruction at the needle tip, and, the duration of the anesthetic effect is inadequate for prolonged surgical procedures. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsuo, Toshihiko, E-mail: matsuot@cc.okayama-u.ac.j; Fujiwara, Hiroyasu; Gobara, Hideo
The aim of this study is to describe vision loss caused by central retinal artery and posterior ciliary artery occlusion as a consequence of sclerotherapy with a polidocanol injection to a glabellar hemangioma. An 18-year-old man underwent direct injection with a 23-gauge needle of 1 mL of a polidocanol-carbon dioxide emulsion into the glabellar subcutaneous hemangioma under ultrasound visualization of the needle tip by radiologists. He developed lid swelling the next day, and 3 days later at referral, the visual acuity in the left eye was no light perception. Funduscopy revealed central retinal artery occlusion and fluorescein angiography disclosed nomore » perfusion at all in the left fundus, indicating concurrent posterior ciliary artery occlusion. The patient also showed mydriasis, blepharoptosis, and total external ophthalmoplegia on the left side. Magnetic resonance imaging demonstrated the swollen medial rectus muscle. In a month, blepharoptosis and ophthalmoplegia resolved but the visual acuity remained no light perception. Sclerosing therapy for facial hemangioma may develop a severe complication such as permanent visual loss.« less
3D ultrasound image guidance system used in RF uterine adenoma and uterine bleeding ablation system
NASA Astrophysics Data System (ADS)
Ding, Mingyue; Luo, Xiaoan; Cai, Chao; Zhou, Chengping; Fenster, Aaron
2006-03-01
Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese women. Many women lose their fertility from these diseases. Currently, a minimally invasive ablation system using an RF button electrode is being used in Chinese hospitals to destroy tumor cells or stop bleeding. In this paper, we report on a 3D US guidance system developed to avoid accidents or death of the patient by inaccurate localization of the tumor position during treatment. A 3D US imaging system using a rotational scanning approach of an abdominal probe was built. In order to reduce the distortion produced when the rotational axis is not collinear with the central beam of the probe, a new 3D reconstruction algorithm is used. Then, a fast 3D needle segmentation algorithm is used to find the electrode. Finally, the tip of electrode is determined along the segmented 3D needle and the whole electrode is displayed. Experiments with a water phantom demonstrated the feasibility of our approach.
Broadly Protective Shigella Vaccine Based on Type III Secretion Apparatus Proteins
Martinez-Becerra, Francisco J.; Kissmann, Julian M.; Diaz-McNair, Jovita; Choudhari, Shyamal P.; Quick, Amy M.; Mellado-Sanchez, Gabriela; Clements, John D.
2012-01-01
Shigella spp. are food- and waterborne pathogens that cause severe diarrheal and dysenteric disease associated with high morbidity and mortality. Individuals most often affected are children under 5 years of age in the developing world. The existence of multiple Shigella serotypes and the heterogenic distribution of pathogenic strains, as well as emerging antibiotic resistance, require the development of a broadly protective vaccine. All Shigella spp. utilize a type III secretion system (TTSS) to initiate infection. The type III secretion apparatus (TTSA) is the molecular needle and syringe that form the energized conduit between the bacterial cytoplasm and the host cell to transport effector proteins that manipulate cellular processes to benefit the pathogen. IpaB and IpaD form a tip complex atop the TTSA needle and are required for pathogenesis. Because they are common to all virulent Shigella spp., they are ideal candidate antigens for a subunit-based, broad-spectrum vaccine. We examined the immunogenicity and protective efficacy of IpaB and IpaD, alone or combined, coadministered with a double mutant heat-labile toxin (dmLT) from Escherichia coli, used as a mucosal adjuvant, in a mouse model of intranasal immunization and pulmonary challenge. Robust systemic and mucosal antibody- and T cell-mediated immunities were induced against both proteins, particularly IpaB. Mice immunized in the presence of dmLT with IpaB alone or IpaB combined with IpaD were fully protected against lethal pulmonary infection with Shigella flexneri and Shigella sonnei. We provide the first demonstration that the Shigella TTSAs IpaB and IpaD are promising antigens for the development of a cross-protective Shigella vaccine. PMID:22202122
Validated robotic laparoscopic surgical training in a virtual-reality environment.
Katsavelis, Dimitrios; Siu, Ka-Chun; Brown-Clerk, Bernadette; Lee, Irene H; Lee, Yong Kwon; Oleynikov, Dmitry; Stergiou, Nick
2009-01-01
A robotic virtual-reality (VR) simulator has been developed to improve robot-assisted training for laparoscopic surgery and to enhance surgical performance in laparoscopic skills. The simulated VR training environment provides an effective approach to evaluate and improve surgical performance. This study presents our findings of the VR training environment for robotic laparoscopy. Eight volunteers performed two inanimate tasks in both the VR and the actual training environment. The tasks were bimanual carrying (BC) and needle passing (NP). For the BC task, the volunteers simultaneously transferred two plastic pieces in opposite directions five times consecutively. The same volunteers passed a surgical needle through six pairs of holes in the NP task. Both tasks require significant bimanual coordination that mimics actual laparoscopic skills. Data analysis included time to task completion, speed and distance traveled of the instrument tip, as well as range of motion of the subject's wrist and elbow of the right arm. Electromyography of the right wrist flexor and extensor were also analyzed. Paired t-tests and Pearson's r were used to explore the differences and correlations between the two environments. There were no significant differences between the actual and the simulated VR environment with respect to the BC task, while there were significant differences in almost all dependent parameters for the NP task. Moderate to high correlations for most dependent parameters were revealed for both tasks. Our data shows that the VR environment adequately simulated the BC task. The significant differences found for the NP task may be attributed to an oversimplification in the VR environment. However, they do point to the need for improvements in the complexity of our VR simulation. Further research work is needed to develop effective and reliable VR environments for robotic laparoscopic training.
NASA Astrophysics Data System (ADS)
Khongpracha, P.; Probst, M.; Limtrakul, J.
2008-07-01
The interactions of a gold atom with: (a) a single-wall carbon nanohorn (SWNH) conic tip; (b) with a single-wall carbon nanotube (SWNT) tip; and (c) their complexes with a CO molecule were studied using first-principle calculations based on density functional theory. The analysis of the pyramidalization angle (θp) as well as the π-orbital misalignment angles indicate that there should be many reactive carbon sites on the tips of SWNH and SWNT. It was found that SWNH provides reactive sites that can more selectively interact with the target atom. We identified five sites on both the SWNT tip and the nanohorn where attachment of a gold atom leads to a stable complex. This metal is found to be bi-coordinated with the tip of SWNH, while it is mono-coordinated with the SWNT tip. The largest interaction energies are -10.75 kcal/mol and -16.17 kcal/mol, respectively. The CO probe molecule binds to Au on the Au/SWNH or Au/SWNT tips with interaction energies of -22.34 and -18.29 kcal/mol, respectively. The main contributions of the interaction with both carbon nanostructures stems from σ-donation and π-backbonding. The results suggest that SWNHs could be one of the promising candidates for the development of high-specifity nanosensors.
De Las Casas, L E; Bardales, R H
2000-05-01
Mucous retention cyst (MRC) is a common submucosal lesion of the oral cavity that, when deeply seated, simulates a neoplasm. This report describes the fine-needle aspiration cytology findings of a lingual MRC of complex architecture and with metaplastic epithelium. In addition, we emphasize its cytologic differential diagnosis from other benign and malignant cystic lesions of the tongue. To the best of our knowledge, this is the first report of aspiration cytology of a complex MRC of the tongue. Copyright 2000 Wiley-Liss, Inc.
Sun, Ping; Tropea, Joseph E.; Austin, Brian P.; Cherry, Scott; Waugh, David S.
2008-01-01
Summary The plague-causing bacterium Yersinia pestis utilizes a Type III Secretion System (T3SS) to deliver effector proteins into mammalian cells where they interfere with signal transduction pathways that mediate phagocytosis and the inflammatory response. Effector proteins are injected through a hollow needle structure composed of the protein YscF. YscG and YscE act as "chaperones" to prevent premature polymerization of YscF in the cytosol of the bacterium prior to assembly of the needle. Here, we report the crystal structure of the YscEFG protein complex at 1.8 Å resolution. Overall, the structure is similar to that of the analogous PscEFG complex from the Pseudomonas aeruginosa T3SS, but there are noteworthy differences. The structure confirms that, like PscG, YscG is a member of the tetratricopeptide repeat (TPR) family of proteins. YscG binds tightly to the C-terminal half of YscF, implying that it is this region of YscF that controls its polymerization into the needle structure. YscE interacts with the N-terminal TPR motif of YscG but makes very little direct contact with YscF. Its function may be to stabilize the structure of YscG and/or to participate in recruiting the complex to the secretion apparatus. No electron density could be observed for the N-terminal 49 residues of YscF. This and additional evidence suggest that the N-terminus of YscF is disordered in the complex with YscE and YscG. As expected, conserved residues in the C-terminal half of YscF mediate important intra- and intermolecular interactions in the complex. Moreover, the phenotypes of some previously characterized mutations in the C-terminal half of YscF can be rationalized in terms of the structure of the heterotrimeric YscEFG complex. PMID:18281060
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Ping; Tropea, Joseph E.; Austin, Brian P.
2008-05-03
The plague-causing bacterium Yersinia pestis utilizes a type III secretion system to deliver effector proteins into mammalian cells where they interfere with signal transduction pathways that mediate phagocytosis and the inflammatory response. Effector proteins are injected through a hollow needle structure composed of the protein YscF. YscG and YscE act as 'chaperones' to prevent premature polymerization of YscF in the cytosol of the bacterium prior to assembly of the needle. Here, we report the crystal structure of the YscEFG protein complex at 1.8 {angstrom} resolution. Overall, the structure is similar to that of the analogous PscEFG complex from the Pseudomonasmore » aeruginosa type III secretion system, but there are noteworthy differences. The structure confirms that, like PscG, YscG is a member of the tetratricopeptide repeat family of proteins. YscG binds tightly to the C-terminal half of YscF, implying that it is this region of YscF that controls its polymerization into the needle structure. YscE interacts with the N-terminal tetratricopeptide repeat motif of YscG but makes very little direct contact with YscF. Its function may be to stabilize the structure of YscG and/or to participate in recruiting the complex to the secretion apparatus. No electron density could be observed for the 49 N-terminal residues of YscF. This and additional evidence suggest that the N-terminus of YscF is disordered in the complex with YscE and YscG. As expected, conserved residues in the C-terminal half of YscF mediate important intra- and intermolecular interactions in the complex. Moreover, the phenotypes of some previously characterized mutations in the C-terminal half of YscF can be rationalized in terms of the structure of the heterotrimeric YscEFG complex.« less
Teng, Yi; Ou, Mengchan; Yu, Hai
2018-02-01
To compare the transesophageal echocardiography (TEE) probe as a surface probe with the vascular probe for guiding internal jugular vein (IJV) catheterization. Prospective, randomized, controlled pilot study. University hospital. One hundred cardiac surgery patients, including 50 adult and 50 pediatric patients. Patients in the TEE probe group received right IJV catheterization using the TEE probe, while the vascular probe group used the vascular probe for catheterization. The puncture time, first-attempt success rate, quality of the imaging with needle tip positioning, wire positioning, and catheter positioning were recorded. The incidence of complication or any adverse event also was observed. Adult patients: In the vascular probe group, the success rate for first attempt IJV catheterization was 24/25 (96%), while in the TEE probe group, the success rate for first attempt IJV catheterization was 25/25 (100%). There was no statistical difference in the puncture time, image quality, needle tip positioning, wire positioning, and catheter positioning between groups (p > 0.05). Pediatric patients: The success rate for first-attempt IJV catheterization was 100% in both groups, and there were no statistical differences in the puncture time, image quality, and positioning between the 2 groups (p > 0.05). No complications or adverse events were observed in either group. The TEE probe, used as a surface probe, can be used to guide IJV puncturing and catheterization in cardiac surgery patients with favorable feasibility and safety. Copyright © 2018 Elsevier Inc. All rights reserved.
Javan, Ramin; Zeman, Merissa N
2018-02-01
In the context of medical three-dimensional (3D) printing, in addition to 3D reconstruction from cross-sectional imaging, graphic design plays a role in developing and/or enhancing 3D-printed models. A custom prototype modular 3D model of the liver was graphically designed depicting segmental anatomy of the parenchyma containing color-coded hepatic vasculature and biliary tree. Subsequently, 3D printing was performed using transparent resin for the surface of the liver and polyamide material to develop hollow internal structures that allow for passage of catheters and wires. A number of concepts were incorporated into the model. A representative mass with surrounding feeding arterial supply was embedded to demonstrate tumor embolization. A straight narrow hollow tract connecting the mass to the surface of the liver, displaying the path of a biopsy device's needle, and the concept of needle "throw" length was designed. A connection between the middle hepatic and right portal veins was created to demonstrate transjugular intrahepatic portosystemic shunt (TIPS) placement. A hollow amorphous structure representing an abscess was created to allow the demonstration of drainage catheter placement with the formation of pigtail tip. Percutaneous biliary drain and cholecystostomy tube placement were also represented. The skills of graphic designers may be utilized in creating highly customized 3D-printed models. A model was developed for the demonstration and simulation of multiple hepatobiliary interventions, for training purposes, patient counseling and consenting, and as a prototype for future development of a functioning interventional phantom.
Coded excitation ultrasonic needle tracking: An in vivo study.
Xia, Wenfeng; Ginsberg, Yuval; West, Simeon J; Nikitichev, Daniil I; Ourselin, Sebastien; David, Anna L; Desjardins, Adrien E
2016-07-01
Accurate and efficient guidance of medical devices to procedural targets lies at the heart of interventional procedures. Ultrasound imaging is commonly used for device guidance, but determining the location of the device tip can be challenging. Various methods have been proposed to track medical devices during ultrasound-guided procedures, but widespread clinical adoption has remained elusive. With ultrasonic tracking, the location of a medical device is determined by ultrasonic communication between the ultrasound imaging probe and a transducer integrated into the medical device. The signal-to-noise ratio (SNR) of the transducer data is an important determinant of the depth in tissue at which tracking can be performed. In this paper, the authors present a new generation of ultrasonic tracking in which coded excitation is used to improve the SNR without spatial averaging. A fiber optic hydrophone was integrated into the cannula of a 20 gauge insertion needle. This transducer received transmissions from the ultrasound imaging probe, and the data were processed to obtain a tracking image of the needle tip. Excitation using Barker or Golay codes was performed to improve the SNR, and conventional bipolar excitation was performed for comparison. The performance of the coded excitation ultrasonic tracking system was evaluated in an in vivo ovine model with insertions to the brachial plexus and the uterine cavity. Coded excitation significantly increased the SNRs of the tracking images, as compared with bipolar excitation. During an insertion to the brachial plexus, the SNR was increased by factors of 3.5 for Barker coding and 7.1 for Golay coding. During insertions into the uterine cavity, these factors ranged from 2.9 to 4.2 for Barker coding and 5.4 to 8.5 for Golay coding. The maximum SNR was 670, which was obtained with Golay coding during needle withdrawal from the brachial plexus. Range sidelobe artifacts were observed in tracking images obtained with Barker coded excitation, and they were visually absent with Golay coded excitation. The spatial tracking accuracy was unaffected by coded excitation. Coded excitation is a viable method for improving the SNR in ultrasonic tracking without compromising spatial accuracy. This method provided SNR increases that are consistent with theoretical expectations, even in the presence of physiological motion. With the ultrasonic tracking system in this study, the SNR increases will have direct clinical implications in a broad range of interventional procedures by improving visibility of medical devices at large depths.
Benchmarking of state-of-the-art needle detection algorithms in 3D ultrasound data volumes
NASA Astrophysics Data System (ADS)
Pourtaherian, Arash; Zinger, Svitlana; de With, Peter H. N.; Korsten, Hendrikus H. M.; Mihajlovic, Nenad
2015-03-01
Ultrasound-guided needle interventions are widely practiced in medical diagnostics and therapy, i.e. for biopsy guidance, regional anesthesia or for brachytherapy. Needle guidance using 2D ultrasound can be very challenging due to the poor needle visibility and the limited field of view. Since 3D ultrasound transducers are becoming more widely used, needle guidance can be improved and simplified with appropriate computer-aided analyses. In this paper, we compare two state-of-the-art 3D needle detection techniques: a technique based on line filtering from literature and a system employing Gabor transformation. Both algorithms utilize supervised classification to pre-select candidate needle voxels in the volume and then fit a model of the needle on the selected voxels. The major differences between the two approaches are in extracting the feature vectors for classification and selecting the criterion for fitting. We evaluate the performance of the two techniques using manually-annotated ground truth in several ex-vivo situations of different complexities, containing three different needle types with various insertion angles. This extensive evaluation provides better understanding on the limitations and advantages of each technique under different acquisition conditions, which is leading to the development of improved techniques for more reliable and accurate localization. Benchmarking results that the Gabor features are better capable of distinguishing the needle voxels in all datasets. Moreover, it is shown that the complete processing chain of the Gabor-based method outperforms the line filtering in accuracy and stability of the detection results.
Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.
Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat
2013-09-01
The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.
MO-G-17A-09: Quantitative Autoradiography of Biopsy Specimens Extracted Under PET/CT Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanchon, L; Carlin, S; Schmidtlein, C
2014-06-15
Purpose: To develop a procedure for accurate determination of PET tracer concentration with high spatial accuracy in situ by performing Quantitative Autoradiography of Biopsy Specimens (QABS) extracted under PET/CT guidance. Methods: Autoradiography (ARG) standards were produced from a gel loaded with a known concentration of FDG biopsied with 18G and 20G biopsy needles. Specimens obtained with these needles are generally cylindrical: up to 18 mm in length and about 0.8 and 0.6 mm in diameter respectively. These standards, with similar shape and density as biopsy specimens were used to generate ARG calibration curves.Quantitative ARG was performed to measure the activitymore » concentration in biopsy specimens extracted from ten patients. The biopsy sites were determined according to PET/CT's obtained in the operating room. Additional CT scans were acquired with the needles in place to confirm correct needle placements. The ARG images were aligned with the needle tip in the PET/CT images using the open source CERR software. The mean SUV calculated from the specimen activities (SUVarg) were compared to that from PET (SUVpet) at the needle locations. Results: Calibration curves show that the relation between ARG signal and activity concentration in those standards is linear for the investigated range (up to 150 kBq/ml). The correlation coefficient of SUVarg with SUVpet is 0.74. Discrepancies between SUVarg and SUVpet can be attributed to the small size of the biopsy specimens compared to PET resolution. Conclusion: The calibration procedure using surrogate biopsy specimens provided a method for quantifying the activity within the biopsy cores obtained under FDG-PET guidance. QABS allows mapping the activity concentration in such biopsy specimens with a resolution of about 1mm. QABS is a promising tool for verification of biopsy adequacy by comparing specimen activity to that expected from the PET image. A portion of this research was funded by a research grant from Biospace Lab, 13 rue Georges Auric 75019 Paris, FRANCE.« less
NASA Astrophysics Data System (ADS)
Mizeraczyk, J.; Berendt, A.; Podlinski, J.
2016-05-01
In this paper we present images showing the temporal and spatial evolution of the electrohydrodynamic (EHD) flow of dust particles (cigarette smoke) suspended in still air in a needle-to-plate negative DC corona discharge arrangement just after the corona onset, i.e. in the first stage of development of the EHD particle flow. The experimental apparatus for our study of the EHD flow onset consisted of a needle-to-plate electrode arrangement, high voltage power supply and time-resolved EHD imaging system based on 2D time-resolved particle image velocimetry equipment. The time-resolved flow images clearly show the formation of a ball-like flow structure at the needle tip just after the corona discharge onset, and its evolution into a mushroom-like object moving to the collecting electrode. After a certain time, when the mushroom-like object is still present in the interelectrode gap a second mushroom-like object forms near the needle electrode and starts to move towards the collecting electrode. Before the first mushroom-like object reaches the collecting electrode several similar mushroom-like objects can be formed and presented simultaneously in the interelectrode gap. They look like a series of mushroom-like minijets shot from the needle electrode vicinity towards the collecting electrode. The simultaneous presence of mushroom-like minijets in the interelectrode gap in the corona discharge in particle-seeded air resembles the negative-ion-charged ‘clouds’ (induced by the Trichel pulses) traversing simultaneously the interelectrode gap of the corona discharge in air, predicted a long time ago by Loeb, and Lama and Gallo and recently by Dordizadeh et al. Analysing the time behaviours of the mushroom-like minijets and current waveform in the corona discharge in particle-seeded air, we found that the Trichel pulse trains, formed just after the corona onset initiates the mushroom-like minijets. The first stage of development of the EHD particle flow, the area of which is practically limited to the interelectrode duct, ends when the first mushroom-like minijet reaches the collecting electrode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beaulieu, L.; Racine, E.; Boutaleb, S.
In modern brachytherapy, application of large doses of ionizing radiation in a limited number of fractions is frequent. Furthermore, as with any surgical procedures, brachytherapy is subject to learning curve effects. In this context, there could be advantages of integrating real-time tracking of needles/catheters to existing protocols given the recent prominent advances in tracking technologies. In this work, we review the use of an electromagnetic tracking system (EMTS) based on the second generation Aurora® Planar Field Generator (Northern Digital Inc) and custom design needles (Philips Healthcare) for brachytherapy applications. The position and orientation information is obtained from 5 degrees ofmore » freedom sensors. Basic system performance characterization is performed in well-controlled conditions to establish accuracy and reproducibility as well as potential interference from standard brachytherapy equipment. The results show that sensor locations can be tracked to within 0.04mm (la) when located within 26cm of the generator. Orientation accuracy of the needle remained within ±1° in the same region, but rose quickly at larger distances. The errors on position and orientation strongly dependent the sensor position in the characterization volume (500×500×500mm{sup 3}). The presence of an ultrasound probe was shown to have negligible effects on tracking accuracy. The use of EMTS for automatic catheter/applicator reconstruction was also explored. Reconstruction time was less than 10 sec/channel and tips identification was within 0.69±0.29mm of the reference values. Finally, we demonstrate that hollow needle designs with special EM adaptation also allow for real-time seed drop position estimation. In phantom experiments showed that drop positions were on average within 1.6±0.9mm of the reference position measured from μCT. Altogether, EMTS offer promising benefits in a wide range of brachytherapy applications.« less
Cracks in Complex Bodies: Covariance of Tip Balances
NASA Astrophysics Data System (ADS)
Mariano, Paolo Maria
2008-04-01
In complex bodies, actions due to substructural changes alter (in some cases drastically) the force driving the tip of macroscopic cracks in quasi-static and dynamic growth, and must be represented directly. Here it is proven that tip balances of standard and substructural interactions are covariant. In fact, the former balance follows from the Lagrangian density’s requirement of invariance with respect to the action of the group of diffeomorphisms of the ambient space to itself, the latter balance accrues from an analogous invariance with respect to the action of a Lie group over the manifold of substructural shapes. The evolution equation of the crack tip can be obtained by exploiting invariance with respect to relabeling the material elements in the reference place. The analysis is developed by first focusing on general complex bodies that admit metastable states with substructural dissipation of viscous-like type inside each material element. Then we account for gradient dissipative effects that induce nonconservative stresses; the covariance of tip balances in simple bodies follows as a corollary. When body actions and boundary data of Dirichlet type are absent, the standard variational description of quasi-static crack growth is simply extended to the case of complex materials.
High-frequency ultrasonic wire bonding systems
Tsujino; Yoshihara; Sano; Ihara
2000-03-01
The vibration characteristics of longitudinal-complex transverse vibration systems with multiple resonance frequencies of 350-980 kHz for ultrasonic wire bonding of IC, LSI or electronic devices were studied. The complex vibration systems can be applied for direct welding of semiconductor tips (face-down bonding, flip-chip bonding) and packaging of electronic devices. A longitudinal-complex transverse vibration bonding system consists of a complex transverse vibration rod, two driving longitudinal transducers 7.0 mm in diameter and a transverse vibration welding tip. The vibration distributions along ceramic and stainless-steel welding tips were measured at up to 980 kHz. A high-frequency vibration system with a height of 20.7 mm and a weight of less than 15 g was obtained.
Electrocautery skin incision for neurosurgery procedures--technical note.
Nitta, Naoki; Fukami, Tadateru; Nozaki, Kazuhiko
2011-01-01
The reluctance to incise skin with electrocautery is partly attributable to concerns about excessive scarring and poor wound healing. However, recently no difference was reported in wound complications between the cold scalpel and electrocautery scalpel. We assessed the safety and efficacy of electrocautery skin incision in 22 scalp incisions, including 4 cases of reoperation. Electrocautery skin incisions were created using a sharp needle electrode. The generator unit was set on cutting mode, with power of 6 W and 330 kHz sinusoid waveform. Subcutaneous dissections also used the sharp needle electrode, set on coagulating mode, with power of 10 W and 1 MHz pulse-modulated waveform. Galea incisions used a standard blade tip, set on coagulating mode, with power of 20 W and 1 MHz pulse-modulated waveform. Skin incision with the sharp needle electrode caused no charring of the wound. Little bleeding or oozing were observed and skin clips were not necessary. No wound complication such as necrosis or infection occurred. Electrocautery skin incisions for re-operations were also performed safely without complications. Electrocautery skin incision is sufficiently safe procedure not only for first operation but also for re-operation. Electrocautery skin incision is efficacious, especially for extended operation times, because of little blood loss from the edges of skin incision and possible avoidance of skin edge necrosis or alopecia caused by skin clips.
Microstructural characteristics and aging response of Zn-containing Al-Mg-Si-Cu alloy
NASA Astrophysics Data System (ADS)
Cai, Yuan-hua; Wang, Cong; Zhang, Ji-shan
2013-07-01
Al-Mg-Si-Cu alloys with and without Zn addition were fabricated by conventional ingot metallurgy method. The microstructures and properties were investigated using optical microscopy (OM), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), tensile test, hardness test, and electrical conductivity measurement. It is found that the as-cast Al-Mg-Si-Cu-Zn alloy is composed of coarse dendritic grains, long needle-like β/δ-AlFeSi white intermetallics, and Chinese script-like α-AlFeSi compounds. During high temperature homogenization treatment, only harmful needle-like β-AlFeSi phase undergoes fragmentation and spheroidizing at its tips, and the destructive needle-like δ-phase does not show any morphological and size changes. Phase transitions from β-AlFeSi to α-AlFeSi and from δ-AlFeSi to β-AlFeSi are also not found. Zn addition improves the aging hardening response during the former aging stage and postpones the peak-aged hardness to a long aging time. In T4 condition, Zn addition does not obviously increase the yield strength and decrease the elongation, but it markedly improves paint-bake hardening response during paint-bake cycle. The addition of 0.5wt% Zn can lead to an increment of 99 MPa in yield strength compared with the value of 69 MPa for the alloy without Zn after paint-bake cycle.
B. A. Richardson; N. B. Klopfenstein; P. J. Zambino; G. I. McDonald; B. W. Geils; L. M. Carris
2008-01-01
Cronartium ribicola, the causal agent of white pine blister rust, has been devastating to five-needled white pines in North America since its introduction nearly a century ago. However, dynamic and complex interactions occur among C. ribicola, five-needled white pines, and the environment. To examine potential evolutionary...
Simulation and training of ultrasound supported anaesthesia: a low-cost approach
NASA Astrophysics Data System (ADS)
Schaaf, T.; Lamontain, M.; Hilpert, J.; Schilling, F.; Tolxdorff, T.
2010-03-01
The use of ultrasound imaging technology during techniques of peripheral nerve blockade offers several clinical benefits. Here we report on a new method to educate residents in ultrasound-guided regional anesthesia. The daily challenge for the anesthesiologists is the 3D angle-depending handling of the stimulation needle and the ultrasound probe while watching the 2D ultrasound image on the monitor. Purpose: Our approach describes how a computer-aided simulation and training set for ultrasound-guided regional anesthesia could be built based on wireless low-cost devices and an interactive simulation of a 2D ultrasound image. For training purposes the injection needle and the ultrasound probe are replaced by wireless Bluetooth-connected 3D tracking devices, which are embedded in WII-mote controllers (Nintendo-Brand). In correlation to the tracked 3D positions of the needle and transducer models the visibility and position of the needle should be simulated in the 2D generated ultrasound image. Conclusion: In future, this tracking and visualization software module could be integrated in a more complex training set, where complex injection paths could be trained based on a 3D segmented model and the training results could be part of a curricular e-learning module.
Investigation of an acoustical holography system for real-time imaging
NASA Astrophysics Data System (ADS)
Fecht, Barbara A.; Andre, Michael P.; Garlick, George F.; Shelby, Ronald L.; Shelby, Jerod O.; Lehman, Constance D.
1998-07-01
A new prototype imaging system based on ultrasound transmission through the object of interest -- acoustical holography -- was developed which incorporates significant improvements in acoustical and optical design. This system is being evaluated for potential clinical application in the musculoskeletal system, interventional radiology, pediatrics, monitoring of tumor ablation, vascular imaging and breast imaging. System limiting resolution was estimated using a line-pair target with decreasing line thickness and equal separation. For a swept frequency beam from 2.6 - 3.0 MHz, the minimum resolution was 0.5 lp/mm. Apatite crystals were suspended in castor oil to approximate breast microcalcifications. Crystals from 0.425 - 1.18 mm in diameter were well resolved in the acoustic zoom mode. Needle visibility was examined with both a 14-gauge biopsy needle and a 0.6 mm needle. The needle tip was clearly visible throughout the dynamic imaging sequence as it was slowly inserted into a RMI tissue-equivalent breast biopsy phantom. A selection of human images was acquired in several volunteers: a 25 year-old female volunteer with normal breast tissue, a lateral view of the elbow joint showing muscle fascia and tendon insertions, and the superficial vessels in the forearm. Real-time video images of these studies will be presented. In all of these studies, conventional sonography was used for comparison. These preliminary investigations with the new prototype acoustical holography system showed favorable results in comparison to state-of-the-art pulse-echo ultrasound and demonstrate it to be suitable for further clinical study. The new patient interfaces will facilitate orthopedic soft tissue evaluation, study of superficial vascular structures and potentially breast imaging.
Moris, Maria; Atar, Mustafa; Kadayifci, Abdurrahman; Krishna, Murli; Librero, Ariston; Richie, Eugene; Brugge, William; Wallace, Michael B.
2017-01-01
Background and Objectives: Pancreatic cysts are evaluated by endoscopic ultrasound and fine needle aspiration (EUS). The only accepted treatment is pancreatectomy, which is associated with morbidity and mortality. This study evaluated the optimal thermal dosimetry of a novel radiofrequency ablation device using a standard electrosurgical unit in ex vivo cyst models. Methods: A modified EUS 22-gauge monopolar needle prototype with a tip electrode connected to a standard electrosurgical unit (Erbe USA, Marietta, GA, USA) was used to induce a subboiling point temperature. A cyst model was created using 2-cm sections of porcine small intestine ligated and filled with saline. After ablation, the cyst models were prepared for pathological evaluation. The epithelial layers were measured in at least two different sites with a micrometer and compared with the corresponding control sample. Results: Thirty-two cyst models were ablated with maximum temperatures of 50°C, 60°C, 90°C, and 97°C in 8, 11, 11, and 2 cysts, respectively. Longer ablation times were required to induce higher temperatures. A trend in the reduction in thickness of the measured layers was observed after exposure to higher temperatures. A temperature over 50°C was required for the ablation of the muscularis, submucosa, and villi, and over 60°C was required to ablate the mucosal crypts. Conclusions: In a preclinical model, a novel radiofrequency EUS-capable needle connected to a standard electrosurgical unit using standard low-voltage coagulation provided ablation in a temperature-dependent fashion with a threshold of at least 60°C and a safe cyst margin below 97°C. This potentially will allow low-cost, convenient cyst ablation. PMID:28440238
Petroselli, Gabriela; Mandal, Mridul Kanti; Chen, Lee Chuin; Ruiz, Gustavo T; Wolcan, Ezequiel; Hiraoka, Kenzo; Nonami, Hiroshi; Erra-Balsells, Rosa
2012-03-01
A group of rhenium (I) complexes including in their structure ligands such as CF(3)SO(3)-, CH(3)CO(2)-, CO, 2,2'-bipyridine, dipyridil[3,2-a:2'3'-c]phenazine, naphthalene-2-carboxylate, anthracene-9-carboxylate, pyrene-1-carboxylate and 1,10-phenanthroline have been studied for the first time by mass spectrometry. The probe electrospray ionization (PESI) is a technique based on electrospray ionization (ESI) that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for organometallic complexes obtained by PESI were compared with those obtained by classical ESI and high flow rate electrospray ionization assisted by corona discharge (HF-ESI-CD), an ideal method to avoid decomposition of the complexes and to induce their oxidation to yield intact molecular cation radicals in gas state [M](+·) and to produce their reduction yielding the gas species [M](-·). It was found that both techniques showed in general the intact molecular ions of the organometallics studied and provided additional structure characteristic diagnostic fragments. As the rhenium complexes studied in the present work showed strong absorption in the UV-visible region, particularly at 355 nm, laser desorption ionization (LDI) mass spectrometry experiments could be conducted. Although intact molecular ions could be detected in a few cases, LDI mass spectra showed diagnostic fragments for characterization of the complexes structure. Furthermore, matrix-assisted laser desorption ionization (MALDI) mass spectra were obtained. Nor-harmane, a compound with basic character, was used as matrix, and the intact molecular ions were detected in two examples, in negative ion mode as the [M](-·) species. Results obtained with 2-[(2E)-3-(4-tert-buthylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) as matrix are also described. LDI experiments provided more information about the rhenium complex structures than did the MALDI ones. Copyright © 2012 John Wiley & Sons, Ltd.
Enk, D; Enk, E
1995-11-01
Various in vitro models have been introduced for comparative examinations of post-dural-puncture trauma and measurement of liquor leakage through puncture sites. These models allow simulation of subarachnoid, but not of peridural, pressure. A new two-chamber-model realizes the simulation of both subarachnoid and peridural pressure and allows observation of in vitro punctures with video-documentation. Frame grabbing and (computer-aided) image analysis show new aspects of spinal puncture effects. Therefore, post-dural-puncture trauma and retraction can be objectively visualized by this method, which has not previously been demonstrated. Two-chamber-model consists of two short aluminium cylinders. Native human dura patches (8X8 mm) from fresh cadavers are put (correctly oriented) between two special polyamide seals. Mounted between the upper and lower cylinder, these seals stretch the dura patch, which remains flexible and even in all directions. After filling of the lower (subarachnoid) and upper (peridural) chamber with Ringer lactate solution, positive or negative physiological pressure can be adjusted by way of two (Ringer lactate solution filled) infusion lines in each chamber. Puncturing is performed at an angle of 57 degrees to the dura. The model allows examination with epi-illumination and transmitted (polarized) light. In vitro punctures are observed through an inverted camera lens with an CCD-Hi8 video camera (Canon UC1HI) looking into the peridural chamber and documented by means of an S-VHS video recorder (Panasonic NV-FS200EG). After true-colour frame grabbing by a video digitizer (Fast Screen Machine II), single video frames can be optimized and analysed with a 486-66 MHz computer and conventional software (Corel Draw 3.0, Photostyler 1.1a, DDL Aequitas 1.00b). Punctures demonstrated in this paper have been done under simulation of a transdural gradient of 20 cm water similar to the situation of a recumbent patient (15 cm water in the subarachnoid and -5 cm water in the peridural chamber). The punctures were followed by short-time observation for up to 10 minutes. By making it possible to obtains a picture of the puncture site at 20-ms intervals (because of the PAL norm of 50 half-frames/s), video-documentation has become accepted as superior to conventional photography. When the Ringer lactate solution in the subarachnoid chamber is stained with methylene blue, transdural leakage can easily be observed. The result of this documentation technique demonstrate that not dural puncture can be atraumatic, when a 29-G Quincke needle is used. Calculation on the difference between a digitized video frame before and after the puncture clearly illustrates the dural trauma. Owing to their non-cutting tip, as expected, pencil-point needles leave diffuse changes across the dura patch, whereas a more local trauma was observed after puncturing with cutting-tip needles. The same computer calculation between two video frames allows examination of post-puncture-dural retraction of the puncture site. In this connection, we found that relevant dural retraction is a phenomenon limited to the first minute after puncture. Thin spinal needles with so-called modern tips (e.g. Whitacre, Atraucan) can minimize the post-dural-puncture trauma, whereas thicker, conventional, spinal needles (Quincke) leave considerable dural defects. The two-chamber-model presented allows easy simulation of physiological subarachnoid and peridural pressure. The Ringer lactate solution in the subarachnoid chamber corresponds to the liquor, whereas that in the peridural chamber corresponds to the intercellular (peridural) space. The tension of the dural patch between the polyamide seals is similar to the situation in an anotomical model observed by spinaloscopy (in an earlier study). With the video documentation and computer-aided analysis technique introduced, dural trauma and retraction of the puncture site can be examined and demo
Qin, Jian-Ping; Tang, Shan-Hong; Jiang, Ming-De; He, Qian-Wen; Chen, Hong-Bin; Yao, Xin; Zeng, Wei-Zheng; Gu, Ming
2015-08-28
To describe a method for the transjugular intrahepatic portal systemic shunt (TIPS) placement performed with the aid of contrast-enhanced computed tomography (CECT) and three-dimensional reconstructed vascular images (3D RVIs), and to assess its safety and effectiveness. Four hundred and ninety patients were treated with TIPS between January 2005 and December 2012. All patients underwent liver CECT and reconstruction of 3D RVIs of the right hepatic vein to portal vein (PV) prior to the operation. The 3D RVIs were carefully reviewed to plan the puncture path from the start to target points for needle pass through the PV in the TIPS procedure. The improved TIPS procedure was successful in 483 (98.6%) of the 490 patients. The number of punctures attempted was one in 294 (60%) patients, 2 to 3 in 147 (30%) patients, 4 to 6 in 25 (5.1%) patients and more than 6 in 17 (3.5%) patients. Seven patients failed. Of the 490 patients, 12 had punctures into the artery, 15 into the bile duct, eight into the gallbladder, and 18 through the liver capsule. Analysis of the portograms from the 483 successful cases indicated that the puncture points were all located distally to the PV bifurcation on anteroposterior images, while the points were located proximally to the bifurcation in the three cases with intraabdominal bleeding. The complications included three cases of bleeding, of whom one died and two needed surgery. Use of CECT and 3D RVIs to plan the puncture path for TIPS procedure is safe, simple and effective for clinical use.
Changes in metal mobility associated with bark beetle-induced tree mortality.
Mikkelson, Kristin M; Bearup, Lindsay A; Navarre-Sitchler, Alexis K; McCray, John E; Sharp, Jonathan O
2014-05-01
Recent large-scale beetle infestations have caused extensive mortality to conifer forests resulting in alterations to dissolved organic carbon (DOC) cycling, which in turn can impact metal mobility through complexation. This study analyzed soil-water samples beneath impacted trees in concert with laboratory flow-through soil column experiments to explore possible impacts of the bark beetle infestation on metal release and transport. The columns mimicked field conditions by introducing pine needle leachate and artificial rainwater through duplicate homogenized soil columns and measuring effluent metal (focusing on Al, Cu, and Zn) and DOC concentrations. All three metals were consistently found in higher concentrations in the effluent of columns receiving pine needle leachate. In both the field and laboratory, aluminum mobility was largely correlated with the hydrophobic fraction of the DOC, while copper had the largest correlation with total DOC concentrations. Geochemical speciation modeling supported the presence of DOC-metal complexes in column experiments. Copper soil water concentrations in field samples supported laboratory column results, as they were almost twice as high under grey phase trees than under red phase trees further signifying the importance of needle drop. Pine needle leachate contained high concentrations of Zn (0.1 mg l(-1)), which led to high effluent zinc concentrations and sorption of zinc to the soil matrix representing a future potential source for release. In support, field soil-water samples underneath beetle-impacted trees where the needles had recently fallen contained approximately 50% more zinc as samples from under beetle-impacted trees that still held their needles. The high concentrations of carbon in the pine needle leachate also led to increased sorption in the soil matrix creating the potential for subsequent carbon release. While unclear if manifested in adjacent surface waters, these results demonstrate an increased potential for Zn, Cu, and Al mobility, along with increased deposition of metals and carbon beneath beetle-impacted trees.
Crystal growth and fluid mechanics problems in directional solidification
NASA Technical Reports Server (NTRS)
Tanveer, Saleh; Baker, Gregory R.; Foster, Michael R.
1994-01-01
Broadly speaking, our efforts have been concentrated in two aspects of directional solidification: (A) a more complete theoretical understanding of convection effects in a Bridgman apparatus; and (B) a clear understanding of scalings of various features of dendritic crystal growth in the sensitive limit of small capillary effects. For studies that fall within class A, the principal objectives are as follows: (A1) Derive analytical formulas for segregation, interfacial shape and fluid velocities in mathematically amenable asymptotic limits. (A2) Numerically verify and extend asymptotic results to other ranges of parameter space with a view to a broader physical understanding of the general trends. With respect to studies that fall within class B, the principal objectives include answering the following questions about dendritic crystal growth: (B1) Are there unsteady dendrite solutions in 2-D to the completely nonlinear time evolving equations in the small surface tension limit with only a locally steady tip region with well defined tip radius and velocity? Is anisotropy in surface tension necessary for the existence of such solutions as it is for a true steady state needle crystal? How does the size of such a local region depend on capillary effects, anisotropy and undercooling? (B2) How do the different control parameters affect the nonlinear amplification of tip noise and dendritic side branch coarsening?
NASA Astrophysics Data System (ADS)
Xing, Hui; Dong, Xianglei; Wang, Jianyuan; Jin, Kexin
2018-04-01
In this study, a thin-interface phase-field model was employed to study the orientation dependence of the columnar dendritic growth with sidebranching behaviors in directional solidification. It was found that the dimensionless tip undercooling increases with the increase of misorientation angle for three pulling velocities. The primary spacing is found to be a function of misorientation angle, and the dimensionless primary spacing with respect to the misorientation angle follows the orientation correction given by Gandin and Rappaz (Acta. Metall. 42:2233-2246, 1994). For the analysis of the dendritic tip, the two-dimensional (2-D) form of the nonaxisymmetric needle crystal was used to determine the radius of the tilted columnar dendrite. Based on the definitions of open side and constrained side of the dendrite, the analysis of the width active sidebranches and the dendritic area in 2-D with respect to the distance from the dendritic tip was carried out to investigate the asymmetrical dendrite envelop and sidebranching behaviors on the two sides in directional solidification. The obtained prefactor and exponent with respect to misorientation angle are discussed, showing that the sidebranching behaviors of a tilted columnar dendritic array obey a similar power-law relationship with that of a free dendritic growth.
Borgeat, A; Ekatodramis, G; Guzzella, S; Ruland, P; Votta-Velis, G; Aguirre, J
2012-12-01
The influence of the muscular response elicited by neurostimulation on the success rate of interscalene block using a catheter (ISC) is unknown. In this investigation, we compared the success rate of ISC placement as indicated by biceps or deltoid, triceps, or both twitches. Three hundred (ASA I-II) patients presenting for elective arthroscopic rotator cuff repair were prospectively randomized to assessment by biceps (Group B) or deltoid, triceps, or both twitches (Group DT). All ISCs were placed with the aid of neurostimulation. The tip of the stimulating needle was placed after disappearance of either biceps or deltoid, triceps, or both twitches at 0.3 mA. The catheter was advanced 2-3 cm past the tip of the needle and the block was performed using 40 ml ropivacaine 0.5%. Successful block was defined as sensory block of the supraclavicular nerve and sensory and motor block involving the axillary, radial, median, and musculocutaneous nerves within 30 min. Success rate was 98.6% in Group DT compared with 92.5% in Group B (95% confidence interval 0.01-0.11; P<0.02). Supplemental analgesics during handling of the posterior part of the shoulder capsule were needed in two patients in Group DT and seven patients in Group B. Three patients in Group B had an incomplete radial nerve distribution anaesthesia necessitating general anaesthesia. One patient in Group B had an incomplete posterior block extension of the supraclavicular nerve. No acute or late complications were observed. Eliciting deltoid, triceps, or both twitches was associated with a higher success rate compared with eliciting biceps twitches during continuous interscalene block.
Holefors, Anna; Opseth, Lars; Ree Rosnes, Anne Katrine; Ripel, Linda; Snipen, Lars; Fossdal, Carl Gunnar; Olsen, Jorunn E
2009-02-01
In woody plants of the temperate zone short photoperiod (SD) leads to growth cessation. In angiosperms CONSTANS (CO) or CO-like genes play an important role in the photoperiodic control of flowering, tuberisation and shoot growth. To investigate the role of CO-like genes in photoperiodic control of shoot elongation in gymnosperms, PaCOL1 and PaCOL2 were isolated from Norway spruce. PaCOL1 encodes a 3.9kb gene with a predicted protein of 444 amino acids. PaCOL2 encodes a 1.2kb gene with a predicted protein of 385 amino acids. Both genes consist of two exons and have conserved domains found in other CO-like genes; two zinc finger domains, a CCT and a COOH domain. PaCOL1 and PaCOL2 fall into the group 1c clade of the CO-like genes, and are thus distinct from Arabidopsis CO that belongs to group 1a. Transcript levels of both PaCOL-genes appear to be light regulated, an increasing trend was observed upon transition from darkness to light, and a decreasing trend during darkness. The increasing trend at dawn was observed both in needles and shoot tips, whereas the decreasing trend in darkness was most prominent in shoot tips, and limited to the late part of the dark period in needles. The transcript levels of both genes decreased significantly in both tissues under SD prior to growth cessation and bud formation. This might suggest an involvement in photoperiodic control of shoot elongation or might be a consequence of regulation by light.
Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2017-02-01
A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.
NASA Astrophysics Data System (ADS)
Bhattad, Srikanth; Escoto, Abelardo; Malthaner, Richard; Patel, Rajni
2015-03-01
Brachytherapy and thermal ablation are relatively new approaches in robot-assisted minimally invasive interventions for treating malignant tumors. Ultrasound remains the most favored choice for imaging feedback, the benefits being cost effectiveness, radiation free, and easy access in an OR. However it does not generally provide high contrast, noise free images. Distortion occurs when the sound waves pass through a medium that contains air and/or when the target organ is deep within the body. The distorted images make it quite difficult to recognize and localize tumors and surgical tools. Often tools, such as a bevel-tipped needle, deflect from its path during insertion, making it difficult to detect the needle tip using a single perspective view. The shifting of the target due to cardiac and/or respiratory motion can add further errors in reaching the target. This paper describes a comprehensive system that uses robot dexterity to capture 2D ultrasound images in various pre-determined modes for generating 3D ultrasound images and assists in maneuvering a surgical tool. An interactive 3D virtual reality environment is developed that visualizes various artifacts present in the surgical site in real-time. The system helps to avoid image distortion by grabbing images from multiple positions and orientation to provide a 3D view. Using the methods developed for this application, an accuracy of 1.3 mm was achieved in target attainment in an in-vivo experiment subjected to tissue motion. An accuracy of 1.36 mm and 0.93 mm respectively was achieved for the ex-vivo experiments with and without external induced motion. An ablation monitor widget that visualizes the changes during the complete ablation process and enables evaluation of the process in its entirety is integrated.
User's manual for PEPSIG NASA tip vortex version
NASA Technical Reports Server (NTRS)
Tsai, Tommy M.; Dejong, Frederick J.; Levy, Ralph
1988-01-01
The tip vortex flowfield plays a significant role in the performance of advanced aircraft propellers. The flowfield in the tip region is complex, three-dimensional and viscous with large secondary velocities. A computer code was developed to predict the tip vortex flowfield of advanced aircraft propellers. This document is the user's manual. The analysis and a series of test cases are presented in NASA-CR-182179.
Unusual foreign bodies in the orofacial region.
Passi, Sidhi; Sharma, Neeraj
2012-01-01
Foreign bodies may be deposited in the oral cavity either by traumatic injury or iatrogenically. Among the commonly encountered iatrogenic foreign bodies are restorative materials like amalgam, obturation materials, broken instruments, needles, and so forth. The discovery of foreign bodies in the teeth is a special situation, which is often diagnosed accidentally. Detailed case history, clinical and radiographic examinations are necessary to come to a conclusion about the nature, size, location of the foreign body, and the difficulty involved in its retrieval. It is more common to find this situation in children as it is a well-known fact that children often tend to have the habit of placing foreign objects in the mouth. Sometimes the foreign objects get stuck in the root canals of the teeth, which the children do not reveal to their parents due to fear. These foreign objects may act as a potential source of infection and may later lead to a painful condition. This paper discusses the presence of unusual foreign bodies-a tip of the metallic compass, stapler pin, copper strip, and a broken sewing needle impregnated in the gingiva and their management.
Unusual Foreign Bodies in the Orofacial Region
Passi, Sidhi; Sharma, Neeraj
2012-01-01
Foreign bodies may be deposited in the oral cavity either by traumatic injury or iatrogenically. Among the commonly encountered iatrogenic foreign bodies are restorative materials like amalgam, obturation materials, broken instruments, needles, and so forth. The discovery of foreign bodies in the teeth is a special situation, which is often diagnosed accidentally. Detailed case history, clinical and radiographic examinations are necessary to come to a conclusion about the nature, size, location of the foreign body, and the difficulty involved in its retrieval. It is more common to find this situation in children as it is a well-known fact that children often tend to have the habit of placing foreign objects in the mouth. Sometimes the foreign objects get stuck in the root canals of the teeth, which the children do not reveal to their parents due to fear. These foreign objects may act as a potential source of infection and may later lead to a painful condition. This paper discusses the presence of unusual foreign bodies—a tip of the metallic compass, stapler pin, copper strip, and a broken sewing needle impregnated in the gingiva and their management. PMID:22830058
Moon, Hye-Sung
2018-06-01
Using the da Vinci single-site platform, surgeons can perform more minimally invasive surgery. However, surgical challenges exist due to the limitations of single-site instrumental movements. To aid in the performance of successful robotic single-site hysterectomy, a new suturing technique using the current set of limited instruments is introduced in this study. New vaginal cuff suturing techniques have been used in 55 robotic single-site hysterectomies in our institute over the past 2 years. A needle driver approach utilizing screwing and advancing the needle driver in the correct direction at an increasing angle from the transverse cuff margin with dragging and formation of an adequate loop of thread was used when suturing the vaginal cuff. Using the new vaginal suturing techniques, easy and firm vaginal cuff closure with reduced operative time relative to previous hysterectomies was achieved. The new vaginal cuff suturing techniques may convince more surgeons to perform robotic single-site hysterectomies more frequently and with greater ease. Copyright © 2018. Published by Elsevier B.V.
2015-01-01
This study describes the O2 reactivity of a series of high-spin mononuclear Fe(II) complexes each containing the facially coordinating tris(4,5-diphenyl-1-methylimidazol-2-yl)phosphine (Ph2TIP) ligand and one of the following bidentate, redox-active ligands: 4-tert-butylcatecholate (tBuCatH–), 4,6-di-tert-butyl-2-aminophenolate (tBu2APH–), or 4-tert-butyl-1,2-phenylenediamine (tBuPDA). The preparation and X-ray structural characterization of [Fe2+(Ph2TIP)(tBuCatH)]OTf, [3]OTf and [Fe2+(Ph2TIP)(tBuPDA)](OTf)2, [4](OTf)2 are described here, whereas [Fe2+(Ph2TIP)(tBu2APH)]OTf, [2]OTf was reported in our previous paper [Bittner et al., Chem.—Eur. J.2013,19, 9686–9698]. These complexes mimic the substrate-bound active sites of nonheme iron dioxygenases, which catalyze the oxidative ring-cleavage of aromatic substrates like catechols and aminophenols. Each complex is oxidized in the presence of O2, and the geometric and electronic structures of the resulting complexes were examined with spectroscopic (absorption, EPR, Mössbauer, resonance Raman) and density functional theory (DFT) methods. Complex [3]OTf reacts rapidly with O2 to yield the ferric-catecholate species [Fe3+(Ph2TIP)(tBuCat)]+ (3ox), which undergoes further oxidation to generate an extradiol cleavage product. In contrast, complex [4]2+ experiences a two-electron (2e–), ligand-based oxidation to give [Fe2+(Ph2TIP)(tBuDIBQ)]2+ (4ox), where DIBQ is o-diiminobenzoquinone. The reaction of [2]+ with O2 is also a 2e– process, yet in this case both the Fe center and tBu2AP ligand are oxidized; the resulting complex (2ox) is best described as [Fe3+(Ph2TIP)(tBu2ISQ)]+, where ISQ is o-iminobenzosemiquinone. Thus, the oxidized complexes display a remarkable continuum of electronic structures ranging from [Fe3+(L2–)]+ (3ox) to [Fe3+(L•–)]2+ (2ox) to [Fe2+(L0)]2+ (4ox). Notably, the O2 reaction rates vary by a factor of 105 across the series, following the order [3]+ > [2]+ > [4]2+, even though the complexes have similar structures and Fe3+/2+ redox potentials. To account for the kinetic data, we examined the relative abilities of the title complexes to bind O2 and participate in H-atom transfer reactions. We conclude that the trend in O2 reactivity can be rationalized by accounting for the role of proton transfer(s) in the overall reaction. PMID:24697567
Ferraz, Isabela Leite; Barros, Guilherme Antônio Moreira de; Ferreira Neto, Patrícia Gomes; Solanki, Daneshivari; Marques, Mariângela Alencar; Machado, Vânia Maria de Vasconcelos; Cabral, Lucas Wynne; Lima, Rodrigo Moreira E; Vianna, Pedro Thadeu Galvão; Navarro, Lais Helena Camacho; Ganen, Eliana Marisa
2015-01-01
Although there is no documented evidence that tattoo pigments can cause neurological complications, the implications of performing neuraxial anesthesia through tattooed skin are unknown. In this study, we aimed to assess whether spinal puncture performed through tattooed skin of rabbits determines changes over the spinal cord and meninges. In addition, we sought to evaluate the presence of ink fragments entrapped in spinal needles. Thirty-six young male adult rabbits, each weighing between 3400 and 3900 g and having a spine length between 38.5 and 39 cm, were divided by lot into 3 groups as follows: GI, spinal puncture through tattooed skin; GII, spinal puncture through tattooed skin and saline injection; and GIII, spinal puncture through skin free of tattoo and saline injection. After intravenous anesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance with a 22-gauge 2½ Quincke needle. Animals in GII and GIII received 5 μL/cm of spinal length (0.2 mL) of saline intrathecally. In GI, the needle tip was placed into the yellow ligament, and no solution was injected into the intrathecal space; after tattooed skin puncture, 1 mL of saline was injected through the needle over a histological slide to prepare a smear that was dyed by the Giemsa method to enable tissue identification if present. All animals remained in captivity for 21 days under medical observation and were killed by decapitation. The lumbosacral spinal cord portion was removed for histological analysis using hematoxylin-eosin stain. None of the animals had impaired motor function or decreased nociception during the period of clinical observation. None of the animals from the control group (GIII) showed signs of injuries to meninges. In GII, however, 4 animals presented with signs of meningeal injury. The main histological changes observed were focal areas of perivascular lymphoplasmacyte infiltration in the pia mater and arachnoid. There was no signal of injury in neural tissue in any animal of both groups. Tissue coring containing ink pigments was noted in all GI smears from the spinal needles used to puncture the tattooed skin. On the basis of the present results, intrathecal injection of saline through a needle inserted through tattooed skin is capable of producing histological changes over the meninges of rabbits. Ink fragments were entrapped inside the spinal needles, despite the presence of a stylet.
Information extraction from FN plots of tungsten microemitters.
Mussa, Khalil O; Mousa, Marwan S; Fischer, Andreas
2013-09-01
Tungsten based microemitter tips have been prepared both clean and coated with dielectric materials. For clean tungsten tips, apex radii have been varied ranging from 25 to 500 nm. These tips were manufactured by electrochemical etching a 0.1 mm diameter high purity (99.95%) tungsten wire at the meniscus of two molar NaOH solution. Composite micro-emitters considered here are consisting of a tungsten core coated with different dielectric materials-such as magnesium oxide (MgO), sodium hydroxide (NaOH), tetracyanoethylene (TCNE), and zinc oxide (ZnO). It is worthwhile noting here, that the rather unconventional NaOH coating has shown several interesting properties. Various properties of these emitters were measured including current-voltage (IV) characteristics and the physical shape of the tips. A conventional field emission microscope (FEM) with a tip (cathode)-screen (anode) separation standardized at 10 mm was used to electrically characterize the electron emitters. The system was evacuated down to a base pressure of ∼10(-8) mbar when baked at up to ∼180 °C overnight. This allowed measurements of typical field electron emission (FE) characteristics, namely the IV characteristics and the emission images on a conductive phosphorus screen (the anode). Mechanical characterization has been performed through a FEI scanning electron microscope (SEM). Within this work, the mentioned experimental results are connected to the theory for analyzing Fowler-Nordheim (FN) plots. We compared and evaluated the data extracted from clean tungsten tips of different radii and determined deviations between the results of different extraction methods applied. In particular, we derived the apex radii of several clean and coated tungsten tips by both SEM imaging and analyzing FN plots. The aim of this analysis is to support the ongoing discussion on recently developed improvements of the theory for analyzing FN plots related to metal field electron emitters, which in particular introduces a new form of intercept correction factors. The results derived demonstrate the applicability of the applied method on needle shaped - i.e. non planar - emitters as well as its limits. Copyright © 2013 Elsevier B.V. All rights reserved.
Reina, M A; de Leon-Casasola, O A; Lopez, A; De Andres, J; Martin, S; Mora, M
2000-01-01
A study using scanning electron microscopy showed that although the laminas forming the dura mater are concentric and parallel to the surface of the medulla, the fiber layers' orientations are different in each sub-lamina, dispelling the conventional knowledge that all the fibers of the dura are arranged in a parallel direction. Thus, this study evaluated the dural lesions produced by Whitacre and Quincke spinal needles in the external and internal surface of the dura mater of the lower spine area in an attempt to gain more insight into the pathophysiology of postdural puncture headaches (PDPH). The T11-L4 dural membranes from 5 fresh (immediately after extraction of organs for transplantation), male patients declared brain dead, ages 23, 46, 48, 55, and 60 years, were excised by anterior laminectomy. Morphologic orientation of the membrane and normal pH were maintained with an apparatus designed for this purpose. One hundred punctures (20 on each sample) at 90-degree angles were done with a new needle each time, 50 with 25-gauge Whitacre and 50 with 25-gauge Quincke needles. Half of the punctures with the Quincke needles were done with the bevel in parallel direction to the axis of the spinal cord, and the rest with the bevel perpendicular to it. Fixation in solutions of 2.5% glutaraldehyde phosphate buffer, followed by dehydration with acetone, was done 15 minutes after the punctures. After acetone was removed at ideal conditions of temperature and pressure, the specimens were then metallized with carbon followed by gold and inspected under a scanning electron microscope. Twenty-five of the Whitacre and 23 of the Quincke punctures were found for evaluation. There were no differences in the cross-sectional area of the punctures produced by the Whitacre or Quincke needles on the dura. The area of the dural lesions produced by 25-gauge Quincke needles, 15 minutes after they have been withdrawn, was 0.023 mm2 (confidence interval [CI] 95%, 0.015 to 0.027) in the external aspect (epidural surface) and 0.034 mm2 (CI 95%, 0.018 to 0.051) in the internal aspect (arachnoid surface) of the dural sac. The area of the lesions produced by the 25-gauge Whitacre needles was 0.026 mm2 (CI 95%, 0.019 to 0.032) and 0.030 mm2 (CI 95%, 0.025 to 0.036) in the external and internal surfaces of the dural sac, respectively. There were no significant differences in the cross-sectional areas of the punctures produced by the 25-gauge Whitacre or 25-gauge Quincke needles. Moreover, with Quincke needles the dural lesions closed in an 88.3% (CI 95%, 86.3 to 92.4) and 82.7% (CI 95%, 74.1 to 90.9) of their original sizes in the epidural and arachnoid surfaces, respectively. With Whitacre needles, the closure occurred in an 86.8% (CI 95%, 83.8 to 90.3) and 84.8% (CI 95% 81.7 to 87.3) in the dural and arachnoid surfaces, respectively. However, there were differences in the morphology of the lesions. The Whitacre needles produced coarse lesions with significant destruction in the dura's fibers while the Quincke needles produced a 'U'-shaped lesion (flap) that mimics the opened lid of a tin can, regardless of the tip's direction. The needles produced lesions in the dura with different morphology and characteristics. Lesions with the Quincke needles resulted in a clean-cut opening in the dural membrane while the Whitacre needle produced a more traumatic opening with tearing and severe disruption of the collagen fibers. Thus, we hypothesized that the lower incidence of PDPH seen with the Whitacre needles may be explained, in part, by the inflammatory reaction produced by the tearing of the collagen fibers after dural penetration. This inflammatory reaction may result in a significant edema which may act as a plug limiting the leakage of cerebrospinal fluid.
Graham, John H.; Duda, Jeffrey J.; Brown, Michelle L.; Kitchen, Stanley G.; Emlen, John M.; Malol, Jagadish; Bankstahl, Elizabeth; Krzysik, Anthony J.; Balbach, Harold E.; Freeman, D. Carl
2012-01-01
Ecological indicators provide early warning of adverse environmental change, helping land managers adaptively manage their resources while minimizing costly remediation. In 1999 and 2000, we studied two such indicators, growth and developmental instability, of loblolly pine (Pinus taeda L.) influenced by mechanized infantry training at Fort Benning, Georgia. Disturbed areas were used for military training; tracked and wheeled vehicles damaged vegetation and soils. Highly disturbed sites had fewer trees, diminished ground cover, warmer soils in the summer, and more compacted soils with a shallower A-horizon. We hypothesized that disturbance would decrease the growth of needles, branches, and tree rings, increase the complexity of tree rings, and increase the developmental instability of needles. Contrary to our expectations, however, disturbance enhanced growth in the first year of the study, possibly by reducing competition. In the second year, a drought reduced growth of branches and needles, eliminating the stimulatory effect of disturbance. Growth-ring widths increased with growing-season precipitation, and decreased with growing-season temperature over the last 40 years. Disturbance had no effect on tree-ring complexity, as measured by the Hurst exponent. Within-fascicle variation of current-year needle length, a measure of developmental instability, differed among the study populations, but appeared unrelated to mechanical disturbance or drought.
Ahmed, Zubair M; Goodyear, Richard; Riazuddin, Saima; Lagziel, Ayala; Legan, P Kevin; Behra, Martine; Burgess, Shawn M; Lilley, Kathryn S; Wilcox, Edward R; Riazuddin, Sheikh; Griffith, Andrew J; Frolenkov, Gregory I; Belyantseva, Inna A; Richardson, Guy P; Friedman, Thomas B
2006-06-28
Sound and acceleration are detected by hair bundles, mechanosensory structures located at the apical pole of hair cells in the inner ear. The different elements of the hair bundle, the stereocilia and a kinocilium, are interconnected by a variety of link types. One of these links, the tip link, connects the top of a shorter stereocilium with the lateral membrane of an adjacent taller stereocilium and may gate the mechanotransducer channel of the hair cell. Mass spectrometric and Western blot analyses identify the tip-link antigen, a hitherto unidentified antigen specifically associated with the tip and kinocilial links of sensory hair bundles in the inner ear and the ciliary calyx of photoreceptors in the eye, as an avian ortholog of human protocadherin-15, a product of the gene for the deaf/blindness Usher syndrome type 1F/DFNB23 locus. Multiple protocadherin-15 transcripts are shown to be expressed in the mouse inner ear, and these define four major isoform classes, two with entirely novel, previously unidentified cytoplasmic domains. Antibodies to the three cytoplasmic domain-containing isoform classes reveal that each has a different spatiotemporal expression pattern in the developing and mature inner ear. Two isoforms are distributed in a manner compatible for association with the tip-link complex. An isoform located at the tips of stereocilia is sensitive to calcium chelation and proteolysis with subtilisin and reappears at the tips of stereocilia as transduction recovers after the removal of calcium chelators. Protocadherin-15 is therefore associated with the tip-link complex and may be an integral component of this structure and/or required for its formation.
Evaluation of carbon nanotube probes in critical dimension atomic force microscopes.
Choi, Jinho; Park, Byong Chon; Ahn, Sang Jung; Kim, Dal-Hyun; Lyou, Joon; Dixson, Ronald G; Orji, Ndubuisi G; Fu, Joseph; Vorburger, Theodore V
2016-07-01
The decreasing size of semiconductor features and the increasing structural complexity of advanced devices have placed continuously greater demands on manufacturing metrology, arising both from the measurement challenges of smaller feature sizes and the growing requirement to characterize structures in more than just a single critical dimension. For scanning electron microscopy, this has resulted in increasing sophistication of imaging models. For critical dimension atomic force microscopes (CD-AFMs), this has resulted in the need for smaller and more complex tips. Carbon nanotube (CNT) tips have thus been the focus of much interest and effort by a number of researchers. However, there have been significant issues surrounding both the manufacture and use of CNT tips. Specifically, the growth or attachment of CNTs to AFM cantilevers has been a challenge to the fabrication of CNT tips, and the flexibility and resultant bending artifacts have presented challenges to using CNT tips. The Korea Research Institute for Standards and Science (KRISS) has invested considerable effort in the controlled fabrication of CNT tips and is collaborating with the National Institute of Standards and Technology on the application of CNT tips for CD-AFM. Progress by KRISS on the precise control of CNT orientation, length, and end modification, using manipulation and focused ion beam processes, has allowed us to implement ball-capped CNT tips and bent CNT tips for CD-AFM. Using two different generations of CD-AFM instruments, we have evaluated these tip types by imaging a line/space grating and a programmed line edge roughness specimen. We concluded that these CNTs are capable of scanning the profiles of these structures, including re-entrant sidewalls, but there remain important challenges to address. These challenges include tighter control of tip geometry and careful optimization of scan parameters and algorithms for using CNT tips.
Conservative management of a spleen trauma using radiofrequency.
Stella, Mattia; Percivale, Andrea; Pasqualini, Massimo; Pittaluga, Michele; Gandolfo, Nicola; Pellicci, Riccardo
2005-01-01
Conservative operative management of a splenic injury has become more and more employed in order to preserve the immune function of the organ. A case of a rupture of the spleen successfully treated with the use of a radiofrequency thermal energy generator is eported. The parenchymal tear was coagulated by a one cooled tip needle electrode. There were no postoperative complications and the function of the spleen was preserved. The technique cannot be applied in case of lesion of the major vessels or in case of avulsion of the hilum. This technique integrates to the others to make the operative conservative management of a splenic injury more and more feasible.
Moche, Michael; Zajonz, Dirk; Kahn, Thomas; Busse, Harald
2010-04-01
To present the clinical setup and workflow of a robotic assistance system for image-guided interventions in a conventional magnetic resonance imaging (MRI) environment and to report our preliminary clinical experience with percutaneous biopsies in various body regions. The MR-compatible, servo-pneumatically driven, robotic device (Innomotion) fits into the 60-cm bore of a standard MR scanner. The needle placement (n = 25) accuracy was estimated by measuring the 3D deviation between needle tip and prescribed target point in a phantom. Percutaneous biopsies in six patients and different body regions were planned by graphically selecting entry and target points on intraoperatively acquired roadmap MR data. For insertion depths between 29 and 95 mm, the average 3D needle deviation was 2.2 +/- 0.7 mm (range 0.9-3.8 mm). Patients with a body mass index of up to approximately 30 kg/m(2) fitted into the bore with the device. Clinical work steps and limitations are reported for the various applications. All biopsies were diagnostic and could be completed without any major complications. Median planning and intervention times were 25 (range 20-36) and 44 (36-68) minutes, respectively. Preliminary clinical results in a standard MRI environment suggest that the presented robotic device provides accurate guidance for percutaneous procedures in various body regions. Shorter procedure times may be achievable by optimizing technical and workflow aspects. (c) 2010 Wiley-Liss, Inc.
Subxyphoid access of the normal pericardium: a novel drug delivery technique.
Laham, R J; Simons, M; Hung, D
1999-05-01
The pericardial space may potentially serve as a drug delivery reservoir that might be used to deliver therapeutic substances to the heart. This study describes a novel delivery technique that enables safe and rapid percutaneous subxyphoid access of the normal pericardium in a large animal model (49 Yorkshire pigs). An epidural introducer needle (Tuohy-17) is advanced gently under fluoroscopic guidance with a continuous positive pressure of 20-30 mm Hg (achieved by saline infusion using an intraflow system). The positive pressure is intended to push the right ventricle (with a lower pressure) away from the needle's path. Entry of the pericardial space is suspected after an increase in the saline flow through the intraflow system. Access to the pericardial space is confirmed by the injection of 1 ml of diluted contrast under fluoroscopy. A soft floppy-tip 0.025" guidewire is then advanced to the pericardial space and the needle is exchanged for an infusion catheter. Access of the pericardial space was achieved in all animals without any adverse events and without any hemodynamic compromise even with the delivery of fluid volumes as large as 50 ml. Histologic examination in 15 animals 4 weeks after pericardial access did not reveal any delivery-related myocardial damage. The safety, ease, and absence of hemodynamic compromise make this technique a potentially useful method for intrapericardial drug delivery and a good alternative to standard pericardiocentesis in patients with small pericardial effusions at higher risk for complications.
Otani, Tetsuhisa; Oshima, Kenzi; Kimpara, Akiyo; Takeda, Michiko; Abdu, Uri; Hayashi, Shigeo
2015-07-01
Stable localization of the signaling complex is essential for the robust morphogenesis of polarized cells. Cell elongation involves molecular signaling centers that coordinately regulate intracellular transport and cytoskeletal structures. In Drosophila bristle elongation, the protein kinase IKKε is activated at the distal tip of the growing bristle and regulates the shuttling movement of recycling endosomes and cytoskeletal organization. However, how the distal tip localization of IKKε is established and maintained during bristle elongation is unknown. Here, we demonstrate that IKKε distal tip localization is regulated by Spindle-F (Spn-F), which is stably retained at the distal tip and functions as an adaptor linking IKKε to cytoplasmic dynein. We found that Javelin-like (Jvl) is a key regulator of Spn-F retention. In jvl mutant bristles, IKKε and Spn-F initially localize to the distal tip but fail to be retained there. In S2 cells, particles that stain positively for Jvl or Spn-F move in a microtubule-dependent manner, whereas Jvl and Spn-F double-positive particles are immobile, indicating that Jvl and Spn-F are transported separately and, upon forming a complex, immobilize each other. These results suggest that polarized transport and selective retention regulate the distal tip localization of the Spn-F-IKKε complex during bristle cell elongation. © 2015. Published by The Company of Biologists Ltd.
Zhao, Ling-Jun; Loewenstein, Paul M; Green, Maurice
2016-12-01
The adenovirus E1A 243R oncoprotein targets TRRAP, a scaffold protein that assembles histone acetyltransferase (HAT) complexes, such as the NuA4/Tip60 complex which mediates transcriptional activity of the proto-oncogene MYC and helps determine the cancer cell phenotype. How E1A transforms cells through TRRAP remains obscure. We performed proteomic analysis with the N-terminal transcriptional repression domain of E1A 243R (E1A 1-80) and showed that E1A 1-80 interacts with TRRAP, p400, and three other members of the NuA4 complex - DMAP1, RUVBL1 and RUVBL2 - not previously shown to associate with E1A 243R. E1A 1-80 interacts with these NuA4 components and MYC through the E1A TRRAP-targeting domain. E1A 243R association with the NuA4 complex was demonstrated by co-immunoprecipitation and analysis with DMAP1, Tip60, and MYC. Significantly, E1A 243R promotes association of MYC/MAX with the NuA4/Tip60 complex, implicating the importance of the MYC/NuA4 pathway in cellular transformation by both MYC and E1A. Copyright © 2016 Elsevier Inc. All rights reserved.
Electrophoresis-mass spectrometry probe
Andresen, Brian D.; Fought, Eric R.
1987-01-01
The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface.
Sapountzi, Vasileia; Logan, Ian R; Robson, Craig N
2006-01-01
TIP60 was originally identified as a cellular acetyltransferase protein that interacts with HIV-1 Tat. As a consequence, the role of TIP60 in transcriptional regulation has been investigated intensively. Recent data suggest that TIP60 has more divergent functions than originally thought and roles for TIP60 in many processes, such as cellular signalling, DNA damage repair, cell cycle and checkpoint control and apoptosis are emerging. TIP60 is a tightly regulated transcriptional coregulator, acting in a large multiprotein complex for a range of transcription factors including androgen receptor, Myc, STAT3, NF-kappaB, E2F1 and p53. This usually involves recruitment of TIP60 acetyltransferase activities to chromatin. Additionally, in response to DNA double strand breaks, TIP60 is recruited to DNA lesions where it participates both in the initial as well as the final stages of repair. Here, we describe how TIP60 is a multifunctional enzyme involved in multiple nuclear transactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong
PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less
NASA Astrophysics Data System (ADS)
Caton, J. A.; Payne, S. E.; Terracina, D. P.; Kihm, K. D.
Experiments have been completed to characterize coal-water slurry sprays from an electronically-controlled accumulator fuel injection system of a diesel engine. The sprays were injected into a pressurized chamber equipped with windows. High speed movies, fuel pressures, and needle lifts were obtained as a function of time, orifice diameter, coal loading, gas density in the chamber, and accumulator fuel pressure. For the base conditions (50% by mass coal loading, 0.4 mm diameter nozzle hole, coal-water slurry pressure of 82 MPa (12,000 psi), and a chamber density of 25 kg/m(exp 3)), the break-up time was 0.30 ms. An empirical correlation for spray tip penetration, break-up time, and initial jet velocity was developed. For the conditions of this study, the spray tip penetration and initial jet velocity were 15% greater for coal-water slurry than for diesel fuel or water. Results of this study and the correlation are specific to the tested coal-water slurry and are not general for other coal-water slurry fuels.
Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil
2017-03-01
The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.
Phase field kinetics of lithium electrodeposits
NASA Astrophysics Data System (ADS)
Ely, David R.; Jana, Aniruddha; García, R. Edwin
2014-12-01
A phase field description is formulated to describe the growth kinetics of an heterogeneously nucleated distribution of lithium electrodeposits. The underlying variational principle includes the bulk electrochemical contributions to the free energy of transformation of the system, the electrolyte-dendrite interfacial energy, and the substrate work of adhesion energetics. Results demonstrate that the rate of electrodeposition at the tip of an isolated dendrite is higher than the rate corresponding to the average overpotential, while the back contact is electrochemically shielded, thus favoring elongated, needle-like shapes. For large populations of electrochemically interacting deposits, two spatially distinct regions of behavior develop: one directly facing the counter-electrode where the local surficial electrodeposition dominates the local kinetics; and a second region, in the vicinity of the substrate-deposit interface, where the electrochemical shielding induced by the tip enables lateral electrochemical lithium exchange dendrite coalescence for small contact angle deposits, and dendrite dewetting and electrodissolution for large contact angle deposits. The underlying physical mechanisms through which some lithium nuclei detach from the depositing substrate, self-induce electrodissolution, while other continue to grow and coalesce are described for different contact angles.
Epperson, B K; Telewski, F W; Plovanich-Jones, A E; Grimes, J E
2001-06-01
The widely distributed Pinus subsection Ponderosae is a species complex that has a transition zone among taxa in the southwestern United States. In southern Arizona and New Mexico at least two recognized taxa, Pinus ponderosa var. scopulorum and Pinus arizonica or P. ponderosa var. arizonica, are known to coexist in close proximity. In this study, we report the existence of populations where the taxa are sympatric. One of the key characteristics distinguishing taxa is the number of needles per fascicle; P. ponderosa typically has three, P. arizonica has five. We examined the spatial distribution of needle-number types in a belt transect that covers a transition zone from nearly pure three-needle types at the top of Mount Lemmon to five-needle types downslope, in the Santa Catalina Mountains, Arizona. The spatial distribution is inconsistent with there being both free interbreeding among types and selective neutrality of types. Trees with intermediate types, having combinations of three, four, and five needles and/or mean numbers of needles between 3.0 and 5.0, are spatially concentrated in the middle of the transition zone. The spatial distribution supports the occurrence of hybridization and introgression, and this is consistent with reported crossabilities of the types. The results suggest that selection is acting, either on needle number per se or on other traits of the ecotype with which it may be in linkage disequilibrium, to maintain the observed steep clinal differentiation.
Normal and variant anatomy of the nasal tip.
Ketcham, Amy S; Dobratz, Eric J
2012-04-01
A thorough understanding of nasal tip anatomy is a prerequisite to understanding the nuances of restructuring the nasal tip. The three-dimensional structural anatomy of the nasal tip is complex. Additionally, the interrelationship between these structures determines the ultimate form and function of the nasal tip. As a result, alteration of one structure in the tip will often lead to change in other portions of the nasal tip. This dynamic concept of anatomy in the nasal tip makes proper alteration of the nasal tip one of the most challenging tasks faced by a rhinoplasty surgeon. This article provides a fundamental knowledge of the normal anatomy of the tip structures and how their interaction with each other determines the shape and support of the lower portion of the nose. It also provides a description of some common variants of tip anatomy that cause patients to seek consultation for rhinoplasty. A proper understanding of the concepts presented provides a foundation to build on as the reader continues to explore the "nuances of the nasal tip." Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Development, diagnostic and applications of radio-frequency plasma reactor
NASA Astrophysics Data System (ADS)
Puac, N.
2008-07-01
In many areas of the industry, plasma processing of materials is a vital technology. Nonequilibrium plasmas proved to be able to produce chemically reactive species at a low gas temperature while maintaining highly uniform reaction rates over relatively large areas (Makabe and Petrovic 2006). At the same time nonequilibrium plasmas provide means for good and precise control of the properties of active particles that determine the surface modification. Plasma needle is one of the atmospheric pressure sources that can be used for treatment of the living matter which is highly sensitive when it comes to low pressure or high temperatures (above 40 C). Dependent on plasma conditions, several refined cell responses are induced in mammalian cells (Sladek et al. 2005). It appears that plasma treatment may find many biomedical applications. However, there are few data in the literature about plasma effects on plant cells and tissues. So far, only the effect of low pressure plasmas on seeds was investigated. It was shown that short duration pretreatments by non equilibrium low temperature air plasma were stimulative in light induced germination of Paulownia tomentosa seeds (Puac et al. 2005). As membranes of plants have different properties to those of animals and as they show a wide range of properties we have tried to survey some of the effects of typical plasma which is envisaged to be used in biotechnological applications on plant cells. In this paper we will make a comparison between two configurations of plasma needle that we have used in treatment of biological samples (Puac et al. 2006). Difference between these two configurations is in the additional copper ring that we have placed around glass tube at the tip of the needle. We will show some of the electrical characteristics of the plasma needle (with and without additional copper ring) and, also, plasma emission intensity obtained by using fast ICCD camera.
Bioprinted chitosan-gelatin thermosensitive hydrogels using an inexpensive 3D printer.
Roehm, Kevin D; Madihally, Sundararajan V
2017-11-30
The primary bottleneck in bioprinting cell-laden structures with carefully controlled spatial relation is a lack of biocompatible inks and printing conditions. In this regard, we explored using thermogelling chitosan-gelatin (CG) hydrogel as a novel bioprinting ink; CG hydrogels are unique in that it undergoes a spontaneous phase change at physiological temperature, and does not need post-processing. In addition, we used a low cost (<$800) compact 3D printer, and modified with a new extruder to print using disposable syringes and hypodermic needles. We investigated (i) the effect of concentration of CG on gelation characteristics, (ii) solution preparation steps (centrifugation, mixing, and degassing) on printability and fiber formation, (iii) the print bed temperature profiles via IR imaging and grid-based assessment using thermocouples, (iv) the effect of feed rate (10-480 cm min -1 ), flow rate (15-60 μl min -1 ) and needle height (70-280 μm) on fiber size and characteristics, and (v) the distribution of neuroblastoma cells in printed fibers, and the viability after five days in culture. We used agarose gel to create uniform print surfaces to maintain a constant gap with the needle tip. These results showed that degassing the solution, and precooling the solution was necessary for obtaining continuous fibers. Fiber size decreased from 760, to 243 μm as the feed rate increased from 10 to 100 cm min -1 . Bed temperature played the greatest role in fiber size, followed by feed rate. Increased needle height initially decreased fiber size but then increased showing an optimum. Cells were well distributed within the fibers and exhibited excellent viability and no contamination after 5 d. Overall we printed 3D, sterile, cell-laden structures with an inexpensive bioprinter and a novel ink, without post-processing. The bioprinter described here and the novel CG hydrogels have significant potential as an ink for bioprinitng various cell-laden structures.
Field emission electric propulsion thruster modeling and simulation
NASA Astrophysics Data System (ADS)
Vanderwyst, Anton Sivaram
Electric propulsion allows space rockets a much greater range of capabilities with mass efficiencies that are 1.3 to 30 times greater than chemical propulsion. Field emission electric propulsion (FEEP) thrusters provide a specific design that possesses extremely high efficiency and small impulse bits. Depending on mass flow rate, these thrusters can emit both ions and droplets. To date, fundamental experimental work has been limited in FEEP. In particular, detailed individual droplet mechanics have yet to be understood. In this thesis, theoretical and computational investigations are conducted to examine the physical characteristics associated with droplet dynamics relevant to FEEP applications. Both asymptotic analysis and numerical simulations, based on a new approach combining level set and boundary element methods, were used to simulate 2D-planar and 2D-axisymmetric probability density functions of the droplets produced for a given geometry and electrode potential. The combined algorithm allows the simulation of electrostatically-driven liquids up to and after detachment. Second order accuracy in space is achieved using a volume of fluid correction. The simulations indicate that in general, (i) lowering surface tension, viscosity, and potential, or (ii) enlarging electrode rings, and needle tips reduce operational mass efficiency. Among these factors, surface tension and electrostatic potential have the largest impact. A probability density function for the mass to charge ratio (MTCR) of detached droplets is computed, with a peak around 4,000 atoms per electron. High impedance surfaces, strong electric fields, and large liquid surface tension result in a lower MTCR ratio, which governs FEEP droplet evolution via the charge on detached droplets and their corresponding acceleration. Due to the slow mass flow along a FEEP needle, viscosity is of less importance in altering the droplet velocities. The width of the needle, the composition of the propellant, the current and the mass efficiency are interrelated. The numerical simulations indicate that more electric power per Newton of thrust on a narrow needle with a thin, high surface tension fluid layer gives better performance.
Optical emission spectroscopy of point-plane corona and back-corona discharges in air
NASA Astrophysics Data System (ADS)
Czech, T.; Sobczyk, A. T.; Jaworek, A.
2011-12-01
Results of spectroscopic investigations and current-voltage characteristics of corona discharge and back discharge on fly-ash layer, generated in point-plane electrode geometry in air at atmospheric pressure are presented in the paper. The characteristics of both discharges are similar but differ in the current and voltage ranges of all the discharge forms distinguished during the experiments. Three forms of back discharge, for positive and negative polarity, were investigated: glow, streamer and low-current back-arc. In order to characterize ionisation and excitation processes in back discharge, the emission spectra were measured and compared with those obtained for normal corona discharge generated in the same electrode configuration but with fly ash layer removed. The emission spectra were measured in two discharge zones: near the tip of needle electrode and near the plate. Visual forms of the discharge were recorded with digital camera and referred to current-voltage characteristics and emission spectra. The measurements have shown that spectral lines emitted by back discharge depend on the form of discharge and the discharge current. From the comparison of the spectral lines of back and normal discharges an effect of fly ash layer on the discharge morphology can be determined. The recorded emission spectra formed by ionised gas and plasma near the needle electrode and fly ash layer are different. It should be noted that in back arc emission, spectral lines of fly ash layer components can be distinguished. On the other hand, in needle zone, the emission of high intensity N2 second positive system and NO γ lines can be noticed. Regardless of these gaseous lines, also atomic lines of dust layer were present in the spectrum. The differences in spectra of back discharge for positive and negative polarities of the needle electrode have been explained by considering the kind of ions generated in the crater in fly ash layer. The aim of these studies is to better understand the discharge processes encountered in electrostatic precipitators.
A Review of Hemolysis Prediction Models for Computational Fluid Dynamics.
Yu, Hai; Engel, Sebastian; Janiga, Gábor; Thévenin, Dominique
2017-07-01
Flow-induced hemolysis is a crucial issue for many biomedical applications; in particular, it is an essential issue for the development of blood-transporting devices such as left ventricular assist devices, and other types of blood pumps. In order to estimate red blood cell (RBC) damage in blood flows, many models have been proposed in the past. Most models have been validated by their respective authors. However, the accuracy and the validity range of these models remains unclear. In this work, the most established hemolysis models compatible with computational fluid dynamics of full-scale devices are described and assessed by comparing two selected reference experiments: a simple rheometric flow and a more complex hemodialytic flow through a needle. The quantitative comparisons show very large deviations concerning hemolysis predictions, depending on the model and model parameter. In light of the current results, two simple power-law models deliver the best compromise between computational efficiency and obtained accuracy. Finally, hemolysis has been computed in an axial blood pump. The reconstructed geometry of a HeartMate II shows that hemolysis occurs mainly at the tip and leading edge of the rotor blades, as well as at the leading edge of the diffusor vanes. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Electrophoresis-mass spectrometry probe
Andresen, B.D.; Fought, E.R.
1987-11-10
The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface. 8 figs.
Two-dimensional nanosecond electric field mapping based on cell electropermeabilization.
Chen, Meng-Tse; Jiang, Chunqi; Vernier, P Thomas; Wu, Yu-Hsuan; Gundersen, Martin A
2009-11-11
Nanosecond, megavolt-per-meter electric pulses cause permeabilization of cells to small molecules, programmed cell death (apoptosis) in tumor cells, and are under evaluation as a treatment for skin cancer. We use nanoelectroporation and fluorescence imaging to construct two-dimensional maps of the electric field associated with delivery of 15 ns, 10 kV pulses to monolayers of the human prostate cancer cell line PC3 from three different electrode configurations: single-needle, five-needle, and flat-cut coaxial cable. Influx of the normally impermeant fluorescent dye YO-PRO-1 serves as a sensitive indicator of membrane permeabilization. The level of fluorescence emission after pulse exposure is proportional to the applied electric field strength. Spatial electric field distributions were compared in a plane normal to the center axis and 15-20 mum from the tip of the center electrode. Measurement results agree well with models for the three electrode arrangements evaluated in this study. This live-cell method for measuring a nanosecond pulsed electric field distribution provides an operationally meaningful calibration of electrode designs for biological applications and permits visualization of the relative sensitivities of different cell types to nanoelectropulse stimulation. PACS Codes: 87.85.M-
Adineh, Vahid R; Marceau, Ross K W; Chen, Yu; Si, Kae J; Velkov, Tony; Cheng, Wenlong; Li, Jian; Fu, Jing
2017-10-01
We present a novel approach for analysis of low-conductivity and insulating materials with conventional pulsed-voltage atom probe tomography (APT), by incorporating an ultrathin metallic coating on focused ion beam prepared needle-shaped specimens. Finite element electrostatic simulations of coated atom probe specimens were performed, which suggest remarkable improvement in uniform voltage distribution and subsequent field evaporation of the insulated samples with a metallic coating of approximately 10nm thickness. Using design of experiment technique, an experimental investigation was performed to study physical vapor deposition coating of needle specimens with end tip radii less than 100nm. The final geometries of the coated APT specimens were characterized with high-resolution scanning electron microscopy and transmission electron microscopy, and an empirical model was proposed to determine the optimal coating thickness for a given specimen size. The optimal coating strategy was applied to APT specimens of resin embedded Au nanospheres. Results demonstrate that the optimal coating strategy allows unique pulsed-voltage atom probe analysis and 3D imaging of biological and insulated samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Mari, Jean Martial; West, Simeon J.; Pratt, Rosalind; David, Anna L.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2016-01-01
Precise device guidance is important for interventional procedures in many different clinical fields including fetal medicine, regional anesthesia, interventional pain management, and interventional oncology. While ultrasound is widely used in clinical practice for real-time guidance, the image contrast that it provides can be insufficient for visualizing tissue structures such as blood vessels, nerves, and tumors. This study was centered on the development of a photoacoustic imaging system for interventional procedures that delivered excitation light in the ranges of 750 to 900 nm and 1150 to 1300 nm, with an optical fiber positioned in a needle cannula. Coregistered B-mode ultrasound images were obtained. The system, which was based on a commercial ultrasound imaging scanner, has an axial resolution in the vicinity of 100 μm and a submillimeter, depth-dependent lateral resolution. Using a tissue phantom and 800 nm excitation light, a simulated blood vessel could be visualized at a maximum distance of 15 mm from the needle tip. Spectroscopic contrast for hemoglobin and lipids was observed with ex vivo tissue samples, with photoacoustic signal maxima consistent with the respective optical absorption spectra. The potential for further optimization of the system is discussed. PMID:26263417
NASA Astrophysics Data System (ADS)
Sankaran, K. J.; Kurian, J.; Chen, H. C.; Dong, C. L.; Y Lee, C.; Tai, N. H.; Lin, I. N.
2012-09-01
Microstructural evolution as a function of substrate temperature (TS) for conducting ultrananocrystalline diamond (UNCD) films is systematically studied. Variation of the sp2 graphitic and sp3 diamond content with TS in the films is analysed from the Raman and near-edge x-ray absorption fine structure spectra. Morphological and microstructural studies confirm that at TS = 700 °C well-defined acicular structures evolve. These nanowire structures comprise sp3 phased diamond, encased in a sheath of sp2 bonded graphitic phase. TS causes a change in morphology and thereby the various properties of the films. For TS = 800 °C the acicular grain growth ceases, while that for TS = 700 °C ceases only upon termination of the deposition process. The grain-growth process for the unique needle-like granular structure is proposed such that the CN species invariably occupy the tip of the nanowire, promoting an anisotropic grain-growth process and the formation of acicular structure of the grains. The electron field emission studies substantiate that the films grown at TS = 700 °C are the most conducting, with conduction mediated through the graphitic phase present in the films.
Meconi, Federica; Castelli, Luigi; Dell’Acqua, Roberto
2014-01-01
Using the event-related potential (ERP) approach, we tracked the time-course of white participants’ empathic reactions to white (own-race) and black (other-race) faces displayed in a painful condition (i.e. with a needle penetrating the skin) and in a nonpainful condition (i.e. with Q-tip touching the skin). In a 280–340 ms time-window, neural responses to the pain of own-race individuals under needle penetration conditions were amplified relative to neural responses to the pain of other-race individuals displayed under analogous conditions. This ERP reaction to pain, whose source was localized in the inferior frontal gyrus, correlated with the empathic concern ratings of the Interpersonal Reactivity Index questionnaire. In a 400–750 ms time-window, the difference between neural reactions to the pain of own-race individuals, localized in the middle frontal gyrus and other-race individuals, localized in the temporoparietal junction was reduced to nil. These findings support a functional, neural and temporal distinction between two sequential processing stages underlying empathy, namely, a race-biased stage of pain sharing/mirroring followed by a race-unbiased stage of cognitive evaluation of pain. PMID:23314008
Reina, M A; López-García, A; de Andrés-Ibáñez, J A; Dittmann, M; Cascales, M R; del Caño, M C; Daneri, J; Zambrano, O
1997-02-01
Comparisons of Quincke needles and non traumatic "pencil point" needles in recent years have reported lower rates of post dural puncture headache using the later type. Our new understanding of the morphology of the human dura mater motivated us to study dural lesions caused by the Whitacre 25 G and Quincke 26 G needles, using scanning electron microscopy with the aim of determining whether there is an anatomic basis for the different outcomes. The dura mater from three fresh cadavers of individuals aged 65, 70 and 72 years were punctured 40 times at an angle of 90 degrees each time. The Whitacre 25 G needle was used for 20 punctures and the Quincke 26 G needle was used for the other 20. Half the punctures were performed with the bevel in the parallel alignment and the other half with the bevel perpendicular to the spinal column. Fifteen min after causing the punctures, specimens were fixed in solutions of glutaraldehyde phosphate buffer and dehydrated in acetone. After critical point removal of the acetone, after the specimens were treated with carbon and metallized with gold. The lesions were examined externally and internally and expressed as the ratio of area of lesion to diameter of the needle that had caused them. Whitacre needle: each lesion consisted in the superimposition of multiple damaged layers that started to close individually. After 15 min the outermost layers were 90% closed and the innermost ones had closed entirely. Layers in the arachnoid surface of the dura mater had closed from 86 to 88%, while deeper layers in the thick part had closed 97 to 98%. Quincke needle: lesions were V-shaped or half-moon shaped, much like the opening formed by a can opener, on both the external and internal surfaces. Alignment of the bevel of the needle parallel to the spinal column did not lead to a different shape of puncture. After 15 min the lesions had closed 94 to 95% on the epidural surface and 95 to 96% on the arachnoid side, a difference attributable to the retraction of the arachnoid layers over the spinal column. Non traumatic beveled dural needles, termed "pencil point needles", only partially separate dural fibers, and lesions caused by these needles develop in a more complex way. The Quincke 26G needle produced a puncture that is morphologically different from that caused by the Whitacre 25G needle, although lesions produced by both types close more than 94% after 15 min. We believe the size of the lesion caused by these needles does not explain the difference in post dural puncture headache due to loss of spinal fluid.
Yuan, Haiguang; Liu, Zhibin; Feng, Weixing
2017-10-12
To evaluate the pain severity, the motor function of the upper limb and the quality of life in the patients of post-stroke shoulder pain treated with the touching-periosteum needling technique of the meridian muscle region theory. One hundred and six cases of post-stroke shoulder pain were randomized into an observation group and a control group, 53 cases in each one. In the observation group, the touching-periosteum needle technique and the rehabilitation training were used on the bases of the theory of meridian muscle region. The points were Jianyuci , Binaoci , Jianliaoci , Jianqianci , Quchi (LI 11), Shousanli (LI 10) and Waiguan (TE 5) on the affected side. The needles were inserted obliquely, at 45°degrees at those extra points to the tendon knots till the needle tips touching periosteum. The needles were manipulated to ensure the qi arrival and then retained for 30 min. The rehabilitation was applied, such as the anti-spasmodic posture, bridge-style movement on the bed, weight transition and balance training, joint activity maintenance training, passive and active movement of shoulder joint, the training for activities of daily living (ADL) and Bobath technique. In the control group, the routine acupuncture and the rehabilitation training were used. The acupints were Jianyu (LI 15), Binao (LI 14), Jianliao (TE 14), Jianqian (Extra), Quchi (LI 11), Shousanli (LI 10) and Waiguan (TE 5). The rehabilitation training was the same as the observation group. The treatment was given once every day, 6 treatments a week. After 20 treatments, the visual analogue scale (VAS), Fugl-Meyer (FMA) score and Barthel (MBI) score were adopted to evaluate the pain severity, the motor function of the upper limb and the ADL. The clinical therapeutic effects were evaluated in the two groups. The VAS scores were reduced after treatment as compared with those before treatment in the two groups, and FMA and MBI scores were all increased as compared with those before treatment, indicating the significant difference statistically ( P <0.05, P <0.01). After treatment, the improvements in the observation group were better than those in the control group (all P <0.05). The curative and remarkably effective rate was 69.8% (37/53) in the observation group, better than 47.2% (25/53) in the control group ( P <0.05). The touching-periosteum needling technique of the meridian muscle region theory obviously improves the pain severity, the motor function of the upper limb and the quality of life in patients of post-stroke shoulder pain. The therapeutic effects are better than the routine acupuncture.
Francica, G; Marone, G; Solbiati, L; D'Angelo, V; Siani, A
2000-01-01
A 53-year-old-man underwent US-guided percutaneous thermal ablation with a cooled-tip needle of three liver metastases from gastric cancer. Six days later, the patient was re-admitted for melena, scleral jaundice, and anemia. Abdominal US disclosed echogenic material in the gallbladder lumen (hemobilia) and a focal lesion with mixed echotexture in segment III (hepatic hematoma). On day 5 portal cavernomatosis was diagnosed at US and confirmed by color Doppler and a helical CT exam. The case described emphasizes that radio-frequency interstitial hyperthermia may cause not only traumatic injury of the liver parenchyma but also thermally mediated damage of vascular structures.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
Clarke, Kris; Harris, Debra; Zweifler, John A; Lasher, Marc; Mortimer, Roger B; Hughes, Susan
2016-01-01
Infectious disease remains a significant social and health concern in the United States. Preventing more people from contracting HIV/AIDS or Hepatitis C (HCV), requires a complex understanding of the interconnection between the biomedical and social dimensions of infectious disease. Opiate addiction in the US has skyrocketed in recent years. Preventing more cases of HIV/AIDS and HCV will require dealing with the social determinants of health. Needle exchange programs (NEPs) are based on a harm reduction approach that seeks to minimize the risk of infection and damage to the user and community. This article presents an exploratory small-scale quantitative study of the injection drug using habits of a group of injection drug users (IDUs) at a needle exchange program in Fresno, California. Respondents reported significant decreases in high risk IDU behaviors, including sharing of needles and to a lesser extent re-using of needles. They also reported frequent use of clean paraphernalia. Greater collaboration between social and health outreach professionals at NEPs could provide important frontline assistance to people excluded from mainstream office-based services and enhance efforts to reduce HIV/AIDS or HCV infection.
Fast 5DOF needle tracking in iOCT.
Weiss, Jakob; Rieke, Nicola; Nasseri, Mohammad Ali; Maier, Mathias; Eslami, Abouzar; Navab, Nassir
2018-06-01
Intraoperative optical coherence tomography (iOCT) is an increasingly available imaging technique for ophthalmic microsurgery that provides high-resolution cross-sectional information of the surgical scene. We propose to build on its desirable qualities and present a method for tracking the orientation and location of a surgical needle. Thereby, we enable the direct analysis of instrument-tissue interaction directly in OCT space without complex multimodal calibration that would be required with traditional instrument tracking methods. The intersection of the needle with the iOCT scan is detected by a peculiar multistep ellipse fitting that takes advantage of the directionality of the modality. The geometric modeling allows us to use the ellipse parameters and provide them into a latency-aware estimator to infer the 5DOF pose during needle movement. Experiments on phantom data and ex vivo porcine eyes indicate that the algorithm retains angular precision especially during lateral needle movement and provides a more robust and consistent estimation than baseline methods. Using solely cross-sectional iOCT information, we are able to successfully and robustly estimate a 5DOF pose of the instrument in less than 5.4 ms on a CPU.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, Tomohiro, E-mail: t-matsu@tokai-u.jp; Mine, Takahiko, E-mail: mine@tsc.u-tokai.ac.jp; Hayashi, Toshihiko, E-mail: t.hayashi@tokai.ac.jp
PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsymore » needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.« less
A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.
Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I
2017-09-01
To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
van der Burg, Thomas
2011-01-01
Background Injection force is a particularly important practical aspect of therapy for patients with diabetes, especially those who have dexterity problems. This laboratory-based study compared the injection force of the SoloSTAR® insulin pen (SoloSTAR; sanofi-aventis) versus other available disposable pens at injection speeds based on the delivered volume of insulin released at the needle. Method Four different prefilled disposable pens were tested: SoloSTAR containing insulin glargine; FlexPen® and the Next Generation FlexPen® (NGFP) (Novo Nordisk), both containing insulin detemir; and KwikPen® containing insulin lispro (Eli Lilly). All pens were investigated using the maximum dispense volume for each pen type [80 units (U) for SoloSTAR; 60 U for the other pens], from the free needle tip dispensing into a beaker. Twenty pens of each type were fitted with the recommended needles and tested at two dose speeds (6 and 10 U/s); each pen was tested twice. Results Mean plateau injection force and maximum injection force were consistently lower with SoloSTAR compared with FlexPen, NGFP, and KwikPen at both injection speeds tested. An injection speed of 10 U/s was associated with higher injection force compared with 6 U/s for all the pens tested (p < .001). Conclusions SoloSTAR stands out because of its low injection force, even when compared with newer insulin pen devices such as the KwikPen and NGFP. This may enable patients, especially those with dexterity problems, to administer insulin more easily and improve management of their diabetes. PMID:21303637
Direct observation of the actin filament by tip-scan atomic force microscopy
Narita, Akihiro; Usukura, Eiji; Yagi, Akira; Tateyama, Kiyohiko; Akizuki, Shogo; Kikumoto, Mahito; Matsumoto, Tomoharu; Maéda, Yuichiro; Ito, Shuichi; Usukura, Jiro
2016-01-01
Actin filaments, the actin–myosin complex and the actin–tropomyosin complex were observed by a tip-scan atomic force microscope (AFM), which was recently developed by Olympus as the AFM part of a correlative microscope. This newly developed AFM uses cantilevers of similar size as stage-scan AFMs to improve substantially the spatial and temporal resolution. Such an approach has previously never been possible by a tip-scan system, in which a cantilever moves in the x, y and z directions. We evaluated the performance of this developed tip-scan AFM by observing the molecular structure of actin filaments and the actin–tropomyosin complex. In the image of the actin filament, the molecular interval of the actin subunits (∼5.5 nm) was clearly observed as stripes. From the shape of the stripes, the polarity of the actin filament was directly determined and the results were consistent with the polarity determined by myosin binding. In the image of the actin–tropomyosin complex, each tropomyosin molecule (∼2 nm in diameter) on the actin filament was directly observed without averaging images of different molecules. Each tropomyosin molecule on the actin filament has never been directly observed by AFM or electron microscopy. Thus, our developed tip-scan AFM offers significant potential in observing purified proteins and cellular structures at nanometer resolution. Current results represent an important step in the development of a new correlative microscope to observe nm-order structures at an acceptable frame rate (∼10 s/frame) by AFM at the position indicated by the fluorescent dye observed under a light microscope. PMID:27242058
NASA Astrophysics Data System (ADS)
Kaneko, Masanao; Tsujita, Hoshio
2015-04-01
In a centrifugal compressor, the leakage flow through the tip clearance generates the tip leakage vortex by the interaction with the main flow, and consequently makes the flow in the impeller passage more complex by the interaction with the passage vortex. In addition, the tip leakage vortex interacts with the shock wave on the suction surface near the blade tip in the transonic centrifugal compressor impeller. Therefore, the detailed examination for the influence of the tip leakage vortex becomes seriously important to improve the aerodynamic performance especially for the transonic centrifugal compressor. In this study, the flows in the transonic centrifugal compressor with and without the tip clearance at the design condition were analyzed numerically by using the commercial CFD code. The computed results revealed that the tip leakage vortex induced by the high loading at the blade tip around the leading edge affected the loss generation by the reduction or the suppression of the shock wave on the suction surface of the blade.
Siefermann-Harms, Dorothea; Payer, Hans Dieter; Schramel, Peter; Lütz, Cornelius
2005-02-01
During two vegetation periods, young clonal spruce trees (Picea abies (L.) Karst.) with sufficient and poor magnesium (Mg) supply were exposed in the environmental chambers of the GSF phytotron to three levels of ozone (daily means: 18-22, 88-130, and 135-190 microg m(-3); 10% reduction at night). Previous year's needles were examined at 4-week intervals with respect to their contents of Mg, Ca, K, Mn, N, P, and chlorophyll (Chl), various parameters of Chl fluorescence, and the stability of the isolated light-harvesting Chl-a/b-protein complex LHC II. The needles of the two nutrition variants contained more than 0.53 or less than 0.27mg Mg g(-1) needle dry matter, respectively. The ratio of variable to maximal Chl-a fluorescence of the dark-adapted needles, Fv/Fm, and the photoinhibitory quenching of Fv after light treatment, SVi.v, were affected by the Mg content of the needles rather than the ozone levels. Changes of the Chl content and the behavior of the LHC II allowed differentiating between a slow process of needle yellowing occurring under Mg deficiency only, and a rapid process of needle yellowing occurring under the combined action of Mg deficiency and ozone pollution. Only the rapid yellowing process was accompanied by destabilization of the LHC II, and the degree of destabilization was correlated with the ozone concentration present in the days before sampling. The results are consistent with observations obtained at a research site in the Central Black Forest (J Plant Physiol 161 (2004) 423).
Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Andrew; Butte, Manish J., E-mail: manish.butte@stanford.edu
2014-08-04
We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, andmore » results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.« less
NASA Astrophysics Data System (ADS)
Hegrová, Jitka; Steiner, Oliver; Goessler, Walter; Tanda, Stefan; Anděl, Petr
2017-09-01
A comprehensive overview of the influence of transport on the environment is presented in this study. The complex analysis of soil and needle samples provides an extensive set of data, which presents elemental contamination of the environment near roads. Traffic pollution (including winter road treatment) has a significant negative influence on our environment. Besides sodium and chlorine from winter maintenance many other elements are emitted into the environment. Three possible sources of contamination are assumed for environmental contamination evaluation: car emission, winter maintenance and abrasion from breaks and clutches. The chemical analysis focused on the description of samples from inorganic point of view. The influence of the contamination potential on the sodium and chlorine content in the samples of 1st year-old and 2nd year-old needles of Norway spruce (Picea abies) and Scots pine (Pinus sylvestris) is discussed. Additional soil samples were taken from each sampling site and analyzed to get insight in the sodium and chlorine distribution. Statistical evaluation was used for interpretation of complex interaction patterns between element concentrations in different aged needles based on localities character including distance from the road and element concentration in soils. This species of needles were chosen because of its heightened sensitivity towards salinization. The study was conducted in different parts of the Czech Republic. The resulting database is a source of valuable information about the influence of transport on the environment.
Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah
2013-01-01
Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941
A novel design for steerable instruments based on laser-cut nitinol.
Dewaele, Frank; Kalmar, Alain F; De Ryck, Frederic; Lumen, Nicolaas; Williams, Leonie; Baert, Edward; Vereecke, Hugo; Kalala Okito, Jean Pierre; Mabilde, Cyriel; Blanckaert, Bart; Keereman, Vincent; Leybaert, Luc; Van Nieuwenhove, Yves; Caemaert, Jacques; Van Roost, Dirk
2014-06-01
Omnidirectional articulated instruments enhance dexterity. In neurosurgery, for example, the simultaneous use of 2 instruments through the same endoscopic shaft remains a difficult feat. It is, however, very challenging to manufacture steerable instruments of the requisite small diameter. We present a new technique to produce such instruments by means of laser cutting. Only 3 coaxial tubes are used. The middle tube has a cutting pattern that allows the steering forces to be transmitted from the proximal to the distal end. In this way the steering part is concealed in the wall of the tube. Large diameter articulated instruments such as for laparoscopy might benefit from the excellent tip stability provided by the same economical technology. Coaxial nitinol tubes are laser-cut with a Rofin Stent Cutter in a specific pattern. The 3 tubes are assembled by sliding them over one another, forming a single composite tube. In a surgical simulator, the neurosurgical microinstruments and laparoscopic needle drivers were evaluated on surgical convenience. Simultaneous use of 2 neurosurgical instruments (1.5 mm diameter) through the same endoscopic shaft proved to be very intuitive. The tip of the steerable laparoscopic instruments (10 mm diameter) could resist a lateral force of more than 20 N. The angle of motion for either instrument was at least 70° in any direction. A new design for steerable endoscopic instruments is presented. It allows the construction in a range from microinstruments to 10-mm laparoscopic devices with excellent tip stability. © The Author(s) 2013.
Evaluation of a polymer implanted port access device.
Brown, J M
1996-01-01
The implanted port vascular access system has provided many patients with safe and reliable vascular access. Its implanted design provides improved body image, reduced maintenance and a better quality of life. The Huber needle has been the standard means of accessing the implanted port system. Because of the problems associated with the Huber needle system, current standards recommend that the Huber needle be changed every 7 days. This evaluation examines the use of a polymer cannula to access the implanted port system. This polymer cannula eliminates many of the problems associated with the Huber needle and provides longer dwell times without increased complications. Seventy nine patients were accessed for a total of 1533 days with the mean dwell time being 19.4 days with no increase in complications associated with port access. To establish implanted port access times of greater than 7 days without increased complications. A multicenter voluntary enrollment evaluation of a medical device. Patients were offered the opportunity to participate in the evaluation if they had an implanted port and were going to be accessed for therapy for periods of 7 days or more. Patients were observed for adverse cutaneous reactions at the insertion site and any port access complications such as sepsis, leakage, changes in portal chamber integrity, and implant pocket integrity. From October 1994 through November 1995, 79 L-Cath for Ports (Luther Medical Products) polymer catheter port access devices (Illustration 1) were inserted in 54 patients. This polymer port access device was used instead of a rigid metal Huber needle for port access. The total number of access days was 1533 days with the mean duration of access being 19.4 days. Two patients experienced blood stream infections while they were accessed with the polymer port access device. These infections ensued with fever of unknown origin as the presenting symptom during neutropenic episodes after chemotherapy treatment. The port access device was removed and the port access device tip was cultured with culture results being negative. No other patients experienced complications related to the port access device. The polymer port access device provided a safe and effective means of extending port access times. This reduced the number of restarts for the patients and could extend portal septum life by exposing the portal septum to fewer accesses.
NASA Astrophysics Data System (ADS)
Nikitichev, Daniil I.; Xia, Wenfeng; West, Simeon J.; Desjardins, Adrien E.; Ourselin, Sebastien; Vercauteren, Tom
2017-03-01
Ultrasound (US) imaging is widely used to guide vascular access procedures such as arterial and venous cannulation. As needle visualisation with US imaging can be very challenging, it is easy to misplace the needle in the patient and it can be life threating. Photoacoustic (PA) imaging is well suited to image medical needles and catheters that are commonly used for vascular access. To improve the success rate, a certain level of proficiency is required that can be gained through extensive practice on phantoms. Unfortunately, commercial training phantoms are expensive and custom-made phantoms usually do not replicate the anatomy very well. Thus, there is a great demand for more realistic and affordable ultrasound and photoacoustic imaging phantoms for vasculature access procedures training. Three-dimensional (3D) printing can help create models that replicate complex anatomical geometries. However, the available 3D printed materials do not possess realistic tissue properties. Alternatively, tissue-mimicking materials can be employed using casting and 3D printed moulds but this approach is limited to the creation of realistic outer shapes with no replication of complex internal structures. In this study, we developed a realistic vasculature access phantom using a combination of mineral oil based materials as background tissue and a non-toxic, water dissolvable filament material to create complex vascular structure using 3D printing. US and PA images of the phantoms comprising the complex vasculature network were acquired. The results show that 3D printing can facilitate the fabrication of anatomically realistic training phantoms, with designs that can be customized and shared electronically.
EPC1/TIP60-Mediated Histone Acetylation Facilitates Spermiogenesis in Mice.
Dong, Yixin; Isono, Kyo-Ichi; Ohbo, Kazuyuki; Endo, Takaho A; Ohara, Osamu; Maekawa, Mamiko; Toyama, Yoshiro; Ito, Chizuru; Toshimori, Kiyotaka; Helin, Kristian; Ogonuki, Narumi; Inoue, Kimiko; Ogura, Atsuo; Yamagata, Kazutsune; Kitabayashi, Issay; Koseki, Haruhiko
2017-10-01
Global histone hyperacetylation is suggested to play a critical role for replacement of histones by transition proteins and protamines to compact the genome during spermiogenesis. However, the underlying mechanisms for hyperacetylation-mediated histone replacement remains poorly understood. Here, we report that EPC1 and TIP60, two critical components of the mammalian nucleosome acetyltransferase of H4 (NuA4) complexes, are coexpressed in male germ cells. Strikingly, genetic ablation of either Epc1 or Tip60 disrupts hyperacetylation and impairs histone replacement, in turn causing aberrant spermatid development. Taking these observations together, we reveal an essential role of the NuA4 complexes for histone hyperacetylation and subsequent compaction of the spermatid genome. Copyright © 2017 American Society for Microbiology.
Fe65 is required for Tip60-directed histone H4 acetylation at DNA strand breaks
Stante, Maria; Minopoli, Giuseppina; Passaro, Fabiana; Raia, Maddalena; Vecchio, Luigi Del; Russo, Tommaso
2009-01-01
Fe65 is a binding partner of the Alzheimer's β-amyloid precursor protein APP. The possible involvement of this protein in the cellular response to DNA damage was suggested by the observation that Fe65 null mice are more sensitive to genotoxic stress than WT counterpart. Fe65 associated with chromatin under basal conditions and its involvement in DNA damage repair requires this association. A known partner of Fe65 is the histone acetyltransferase Tip60. Considering the crucial role of Tip60 in DNA repair, we explored the hypothesis that the phenotype of Fe65 null cells depended on its interaction with Tip60. We demonstrated that Fe65 knockdown impaired recruitment of Tip60-TRRAP complex to DNA double strand breaks and decreased histone H4 acetylation. Accordingly, the efficiency of DNA repair was decreased upon Fe65 suppression. To explore whether APP has a role in this mechanism, we analyzed a Fe65 mutant unable to bind to APP. This mutant failed to rescue the phenotypes of Fe65 null cells; furthermore, APP/APLP2 suppression results in the impairment of recruitment of Tip60-TRRAP complex to DNA double strand breaks, decreased histone H4 acetylation and repair efficiency. On these bases, we propose that Fe65 and its interaction with APP play an important role in the response to DNA damage by assisting the recruitment of Tip60-TRRAP to DNA damage sites. PMID:19282473
Arnuntasupakul, Vanlapa; Van Zundert, Tom C R V; Vijitpavan, Amorn; Aliste, Julian; Engsusophon, Phatthanaphol; Leurcharusmee, Prangmalee; Ah-Kye, Sonia; Finlayson, Roderick J; Tran, De Q H
2016-01-01
Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss of resistance (LOR): when the needle tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. In this randomized trial, we compared conventional and EWA-confirmed LOR in 2 teaching centers. Our research hypothesis was that EWA-confirmed LOR would decrease the failure rate of thoracic epidural blocks. One hundred patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures were randomized to conventional LOR or EWA-LOR. The operator was allowed as many attempts as necessary to achieve a satisfactory LOR (by feel) in the conventional group. In the EWA-LOR group, LOR was confirmed by connecting the epidural needle to a pressure transducer using a rigid extension tubing. Positive waveforms indicated that the needle tip was positioned inside the epidural space. The operator was allowed a maximum of 3 different intervertebral levels to obtain a positive waveform. If waveforms were still absent at the third level, the operator simply accepted LOR as the technical end point. However, the patient was retained in the EWA-LOR group (intent-to-treat analysis).After achieving a satisfactory tactile LOR (conventional group), positive waveforms (EWA-LOR group), or a third intervertebral level with LOR but no waveform (EWA-LOR group), the operator administered a 4-mL test dose of lidocaine 2% with epinephrine 5 μg/mL. Fifteen minutes after the test dose, a blinded investigator assessed the patient for sensory block to ice. Compared with LOR, EWA-LOR resulted in a lower rate of primary failure (2% vs 24%; P = 0.002). Subgroup analysis based on experience level reveals that EWA-LOR outperformed conventional LOR for novice (P = 0.001) but not expert operators. The performance time was longer in the EWA-LOR group (11.2 ± 6.2 vs 8.0 ± 4.6 minutes; P = 0.006). Both groups were comparable in terms of operator's level of expertise, depth of the epidural space, approach, and LOR medium. In the EWA-LOR group, operators obtained a pulsatile waveform with the first level attempted in 60% of patients. However, 40% of subjects required performance at a second or third level. Compared with its conventional counterpart, EWA-confirmed LOR results in a lower failure rate for thoracic epidural blocks (2% vs 24%) in our teaching centers. Confirmatory EWA provides significant benefits for inexperienced operators.
Alar setback technique: a controlled method of nasal tip deprojection.
Foda, H M
2001-11-01
To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires an external rhinoplasty approach and fine technical precision.