Systematic bias of correlation coefficient may explain negative accuracy of genomic prediction.
Zhou, Yao; Vales, M Isabel; Wang, Aoxue; Zhang, Zhiwu
2017-09-01
Accuracy of genomic prediction is commonly calculated as the Pearson correlation coefficient between the predicted and observed phenotypes in the inference population by using cross-validation analysis. More frequently than expected, significant negative accuracies of genomic prediction have been reported in genomic selection studies. These negative values are surprising, given that the minimum value for prediction accuracy should hover around zero when randomly permuted data sets are analyzed. We reviewed the two common approaches for calculating the Pearson correlation and hypothesized that these negative accuracy values reflect potential bias owing to artifacts caused by the mathematical formulas used to calculate prediction accuracy. The first approach, Instant accuracy, calculates correlations for each fold and reports prediction accuracy as the mean of correlations across fold. The other approach, Hold accuracy, predicts all phenotypes in all fold and calculates correlation between the observed and predicted phenotypes at the end of the cross-validation process. Using simulated and real data, we demonstrated that our hypothesis is true. Both approaches are biased downward under certain conditions. The biases become larger when more fold are employed and when the expected accuracy is low. The bias of Instant accuracy can be corrected using a modified formula. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Yu, Shao Hua; Zhu, Jun Peng; Xu, You; Zheng, Lei Lei; Chai, Hao; He, Wei; Liu, Wei Bo; Li, Hui Chun; Wang, Wei
2012-12-01
To study the contribution of executive function to abnormal recognition of facial expressions of emotion in schizophrenia patients. Abnormal recognition of facial expressions of emotion was assayed according to Japanese and Caucasian facial expressions of emotion (JACFEE), Wisconsin card sorting test (WCST), positive and negative symptom scale, and Hamilton anxiety and depression scale, respectively, in 88 paranoid schizophrenia patients and 75 healthy volunteers. Patients scored higher on the Positive and Negative Symptom Scale and the Hamilton Anxiety and Depression Scales, displayed lower JACFEE recognition accuracies and poorer WCST performances. The JACFEE recognition accuracy of contempt and disgust was negatively correlated with the negative symptom scale score while the recognition accuracy of fear was positively with the positive symptom scale score and the recognition accuracy of surprise was negatively with the general psychopathology score in patients. Moreover, the WCST could predict the JACFEE recognition accuracy of contempt, disgust, and sadness in patients, and the perseverative errors negatively predicted the recognition accuracy of sadness in healthy volunteers. The JACFEE recognition accuracy of sadness could predict the WCST categories in paranoid schizophrenia patients. Recognition accuracy of social-/moral emotions, such as contempt, disgust and sadness is related to the executive function in paranoid schizophrenia patients, especially when regarding sadness. Copyright © 2012 The Editorial Board of Biomedical and Environmental Sciences. Published by Elsevier B.V. All rights reserved.
Youngs, Noah; Penfold-Brown, Duncan; Drew, Kevin; Shasha, Dennis; Bonneau, Richard
2013-05-01
Computational biologists have demonstrated the utility of using machine learning methods to predict protein function from an integration of multiple genome-wide data types. Yet, even the best performing function prediction algorithms rely on heuristics for important components of the algorithm, such as choosing negative examples (proteins without a given function) or determining key parameters. The improper choice of negative examples, in particular, can hamper the accuracy of protein function prediction. We present a novel approach for choosing negative examples, using a parameterizable Bayesian prior computed from all observed annotation data, which also generates priors used during function prediction. We incorporate this new method into the GeneMANIA function prediction algorithm and demonstrate improved accuracy of our algorithm over current top-performing function prediction methods on the yeast and mouse proteomes across all metrics tested. Code and Data are available at: http://bonneaulab.bio.nyu.edu/funcprop.html
The accuracy of new wheelchair users' predictions about their future wheelchair use.
Hoenig, Helen; Griffiths, Patricia; Ganesh, Shanti; Caves, Kevin; Harris, Frances
2012-06-01
This study examined the accuracy of new wheelchair user predictions about their future wheelchair use. This was a prospective cohort study of 84 community-dwelling veterans provided a new manual wheelchair. The association between predicted and actual wheelchair use was strong at 3 mos (ϕ coefficient = 0.56), with 90% of those who anticipated using the wheelchair at 3 mos still using it (i.e., positive predictive value = 0.96) and 60% of those who anticipated not using it indeed no longer using the wheelchair (i.e., negative predictive value = 0.60, overall accuracy = 0.92). Predictive accuracy diminished over time, with overall accuracy declining from 0.92 at 3 mos to 0.66 at 6 mos. At all time points, and for all types of use, patients better predicted use as opposed to disuse, with correspondingly higher positive than negative predictive values. Accuracy of prediction of use in specific indoor and outdoor locations varied according to location. This study demonstrates the importance of better understanding the potential mismatch between the anticipated and actual patterns of wheelchair use. The findings suggest that users can be relied upon to accurately predict their basic wheelchair-related needs in the short-term. Further exploration is needed to identify characteristics that will aid users and their providers in more accurately predicting mobility needs for the long-term.
Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf
2017-12-01
The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.
Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian
2017-01-01
Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474
CD-Based Indices for Link Prediction in Complex Network.
Wang, Tao; Wang, Hongjue; Wang, Xiaoxia
2016-01-01
Lots of similarity-based algorithms have been designed to deal with the problem of link prediction in the past decade. In order to improve prediction accuracy, a novel cosine similarity index CD based on distance between nodes and cosine value between vectors is proposed in this paper. Firstly, node coordinate matrix can be obtained by node distances which are different from distance matrix and row vectors of the matrix are regarded as coordinates of nodes. Then, cosine value between node coordinates is used as their similarity index. A local community density index LD is also proposed. Then, a series of CD-based indices include CD-LD-k, CD*LD-k, CD-k and CDI are presented and applied in ten real networks. Experimental results demonstrate the effectiveness of CD-based indices. The effects of network clustering coefficient and assortative coefficient on prediction accuracy of indices are analyzed. CD-LD-k and CD*LD-k can improve prediction accuracy without considering the assortative coefficient of network is negative or positive. According to analysis of relative precision of each method on each network, CD-LD-k and CD*LD-k indices have excellent average performance and robustness. CD and CD-k indices perform better on positive assortative networks than on negative assortative networks. For negative assortative networks, we improve and refine CD index, referred as CDI index, combining the advantages of CD index and evolutionary mechanism of the network model BA. Experimental results reveal that CDI index can increase prediction accuracy of CD on negative assortative networks.
CD-Based Indices for Link Prediction in Complex Network
Wang, Tao; Wang, Hongjue; Wang, Xiaoxia
2016-01-01
Lots of similarity-based algorithms have been designed to deal with the problem of link prediction in the past decade. In order to improve prediction accuracy, a novel cosine similarity index CD based on distance between nodes and cosine value between vectors is proposed in this paper. Firstly, node coordinate matrix can be obtained by node distances which are different from distance matrix and row vectors of the matrix are regarded as coordinates of nodes. Then, cosine value between node coordinates is used as their similarity index. A local community density index LD is also proposed. Then, a series of CD-based indices include CD-LD-k, CD*LD-k, CD-k and CDI are presented and applied in ten real networks. Experimental results demonstrate the effectiveness of CD-based indices. The effects of network clustering coefficient and assortative coefficient on prediction accuracy of indices are analyzed. CD-LD-k and CD*LD-k can improve prediction accuracy without considering the assortative coefficient of network is negative or positive. According to analysis of relative precision of each method on each network, CD-LD-k and CD*LD-k indices have excellent average performance and robustness. CD and CD-k indices perform better on positive assortative networks than on negative assortative networks. For negative assortative networks, we improve and refine CD index, referred as CDI index, combining the advantages of CD index and evolutionary mechanism of the network model BA. Experimental results reveal that CDI index can increase prediction accuracy of CD on negative assortative networks. PMID:26752405
Gullick, Margaret M; Wolford, George
2013-01-01
We examined the brain activity underlying the development of our understanding of negative numbers, which are amounts lacking direct physical counterparts. Children performed a paired comparison task with positive and negative numbers during an fMRI session. As previously shown in adults, both pre-instruction fifth-graders and post-instruction seventh-graders demonstrated typical behavioral and neural distance effects to negative numbers, where response times and parietal and frontal activity increased as comparison distance decreased. We then determined the factors impacting the distance effect in each age group. Behaviorally, the fifth-grader distance effect for negatives was significantly predicted only by positive comparison accuracy, indicating that children who were generally better at working with numbers were better at comparing negatives. In seventh-graders, negative number comparison accuracy significantly predicted their negative number distance effect, indicating that children who were better at working with negative numbers demonstrated a more typical distance effect. Across children, as age increased, the negative number distance effect increased in the bilateral IPS and decreased frontally, indicating a frontoparietal shift consistent with previous numerical development literature. In contrast, as negative comparison task accuracy increased, the parietal distance effect increased in the left IPS and decreased in the right, possibly indicating a change from an approximate understanding of negatives' values to a more exact, precise representation (particularly supported by the left IPS) with increasing expertise. These shifts separately indicate the effects of increasing maturity generally in numeric processing and specifically in negative number understanding.
Apirakviriya, Chayanis; Rungruxsirivorn, Tassawan; Phupong, Vorapong; Wisawasukmongchol, Wirach
2016-05-01
To assess diagnostic accuracy of 3D transvaginal ultrasound (3D-TVS) compared with hysteroscopy in detecting uterine cavity abnormalities in infertile women. This prospective observational cross-sectional study was conducted during the July 2013 to December 2013 study period. Sixty-nine women with infertility were enrolled. In the mid to late follicular phase of each subject's menstrual cycle, 3D transvaginal ultrasound and hysteroscopy were performed on the same day in each patient. Hysteroscopy is widely considered to be the gold standard method for investigation of the uterine cavity. Uterine cavity characteristics and abnormalities were recorded. Diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were evaluated. Hysteroscopy was successfully performed in all subjects. Hysteroscopy diagnosed pathological findings in 22 of 69 cases (31.8%). There were 18 endometrial polyps, 3 submucous myomas, and 1 septate uterus. Three-dimensional transvaginal ultrasound in comparison with hysteroscopy had 84.1% diagnostic accuracy, 68.2% sensitivity, 91.5% specificity, 79% positive predictive value, and 86% negative predictive value. The positive and negative likelihood ratios were 8.01 and 0.3, respectively. 3D-TVS successfully detected every case of submucous myoma and uterine anomaly. For detection of endometrial polyps, 3D-TVS had 61.1% sensitivity, 91.5% specificity, and 83.1% diagnostic accuracy. 3D-TVS demonstrated 84.1% diagnostic accuracy for detecting uterine cavity abnormalities in infertile women. A significant percentage of infertile patients had evidence of uterine cavity pathology. Hysteroscopy is, therefore, recommended for accurate detection and diagnosis of uterine cavity lesion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Predictors of change in depressive symptoms from preschool to first grade.
Reinfjell, Trude; Kårstad, Silja Berg; Berg-Nielsen, Turid Suzanne; Luby, Joan L; Wichstrøm, Lars
2016-11-01
Children's depressive symptoms in the transition from preschool to school are rarely investigated. We therefore tested whether children's temperament (effortful control and negative affect), social skills, child psychopathology, environmental stressors (life events), parental accuracy of predicting their child's emotion understanding (parental accuracy), parental emotional availability, and parental depression predict changes in depressive symptoms from preschool to first grade. Parents of a community sample of 995 4-year-olds were interviewed using the Preschool Age Psychiatric Assessment. The children and parents were reassessed when the children started first grade (n = 795). The results showed that DSM-5 defined depressive symptoms increased. Child temperamental negative affect and parental depression predicted increased, whereas social skills predicted decreased, depressive symptoms. However, such social skills were only protective among children with low and medium effortful control. Further, high parental accuracy proved protective among children with low effortful control and high negative affect. Thus, interventions that treat parental depression may be important for young children. Children with low effortful control and high negative affect may especially benefit from having parents who accurately perceive their emotional understanding. Efforts to enhance social skills may prove particularly important for children with low or medium effortful control.
Accuracy of ultrasound for the prediction of placenta accreta.
Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M
2014-08-01
Ultrasound has been reported to be greater than 90% sensitive for the diagnosis of accreta. Prior studies may be subject to bias because of single expert observers, suspicion for accreta, and knowledge of risk factors. We aimed to assess the accuracy of ultrasound for the prediction of accreta. Patients with accreta at a single academic center were matched to patients with placenta previa, but no accreta, by year of delivery. Ultrasound studies with views of the placenta were collected, deidentified, blinded to clinical history, and placed in random sequence. Six investigators prospectively interpreted each study for the presence of accreta and findings reported to be associated with its diagnosis. Sensitivity, specificity, positive predictive, negative predictive value, and accuracy were calculated. Characteristics of accurate findings were compared using univariate and multivariate analyses. Six investigators examined 229 ultrasound studies from 55 patients with accreta and 56 controls for 1374 independent observations. 1205/1374 (87.7% overall, 90% controls, 84.9% cases) studies were given a diagnosis. There were 371 (27.0%) true positives; 81 (5.9%) false positives; 533 (38.8%) true negatives, 220 (16.0%) false negatives, and 169 (12.3%) with uncertain diagnosis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 53.5%, 88.0%, 82.1%, 64.8%, and 64.8%, respectively. In multivariate analysis, true positives were more likely to have placental lacunae (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.4-1.6), loss of retroplacental clear space (OR, 2.4; 95% CI, 1.1-4.9), or abnormalities on color Doppler (OR, 2.1; 95% CI, 1.8-2.4). Ultrasound for the prediction of placenta accreta may not be as sensitive as previously described. Copyright © 2014 Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sembiring, J.; Jones, F.
2018-03-01
Red cell Distribution Width (RDW) and platelet ratio (RPR) can predict liver fibrosis and cirrhosis in chronic hepatitis B with relatively high accuracy. RPR was superior to other non-invasive methods to predict liver fibrosis, such as AST and ALT ratio, AST and platelet ratio Index and FIB-4. The aim of this study was to assess diagnostic accuracy liver fibrosis by using RDW and platelets ratio in chronic hepatitis B patients based on compared with Fibroscan. This cross-sectional study was conducted at Adam Malik Hospital from January-June 2015. We examine 34 patients hepatitis B chronic, screen RDW, platelet, and fibroscan. Data were statistically analyzed. The result RPR with ROC procedure has an accuracy of 72.3% (95% CI: 84.1% - 97%). In this study, the RPR had a moderate ability to predict fibrosis degree (p = 0.029 with AUC> 70%). The cutoff value RPR was 0.0591, sensitivity and spesificity were 71.4% and 60%, Positive Prediction Value (PPV) was 55.6% and Negative Predictions Value (NPV) was 75%, positive likelihood ratio was 1.79 and negative likelihood ratio was 0.48. RPR have the ability to predict the degree of liver fibrosis in chronic hepatitis B patients with moderate accuracy.
Paudel, Prakash; Kovai, Vilas; Naduvilath, Thomas; Phuong, Ha Thanh; Ho, Suit May; Giap, Nguyen Viet
2016-01-01
To assess validity of teacher-based vision screening and elicit factors associated with accuracy of vision screening in Vietnam. After brief training, teachers independently measured visual acuity (VA) in 555 children aged 12-15 years in Ba Ria - Vung Tau Province. Teacher VA measurements were compared to those of refractionists. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for uncorrected VA (UVA) and presenting VA (PVA) 20/40 or worse in either eye. Chi-square, Fisher's exact test and multivariate logistic regression were used to assess factors associated with accuracy of vision screening. Level of significance was set at 5%. Trained teachers in Vietnam demonstrated 86.7% sensitivity, 95.7% specificity, 86.7% positive predictive value and 95.7% negative predictive value in identifying children with visual impairment using the UVA measurement. PVA measurement revealed low accuracy for teachers, which was significantly associated with child's age, sex, spectacle wear and myopic status, but UVA measurement showed no such associations. Better accuracy was achieved in measurement of VA and identification of children with visual impairment using UVA measurement compared to PVA. UVA measurement is recommended for teacher-based vision screening programs.
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay. PMID:15634970
Accuracy of Self-Reported Cervical and Breast Cancer Screening by Women with Intellectual Disability
ERIC Educational Resources Information Center
Son, Esther; Parish, Susan L.; Swaine, Jamie G.; Luken, Karen
2013-01-01
This study examines the accuracy of self-report of cervical and breast cancer screening by women with intellectual disability ("n" ?=? 155). Data from face-to-face interviews and medical records were analyzed. Total agreement, sensitivity, specificity, positive predictive value and negative predictive value were calculated. Total…
NASA Astrophysics Data System (ADS)
DSuryadi; Delyuzar; Soekimin
2018-03-01
Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.
Optical coherence tomography in the diagnosis of dysplasia and adenocarcinoma in Barret's esophagus
NASA Astrophysics Data System (ADS)
Gladkova, N. D.; Zagaynova, E. V.; Zuccaro, G.; Kareta, M. V.; Feldchtein, F. I.; Balalaeva, I. V.; Balandina, E. B.
2007-02-01
Statistical analysis of endoscopic optical coherence tomography (EOCT) surveillance of 78 patients with Barrett's esophagus (BE) is presented in this study. The sensitivity of OCT device in retrospective open detection of early malignancy (including high grade dysplasia and intramucosal adenocarcinoma (IMAC)) was 75%, specificity 82%, diagnostic accuracy - 80%, positive predictive value- 60%, negative predictive value- 87%. In the open recognition of IMAC sensitivity was 81% and specificity were 85% each. Results of a blind recognition with the same material were similar: sensitivity - 77%, specificity 85%, diagnostic accuracy - 82%, positive predictive value- 70%, negative predictive value- 87%. As the endoscopic detection of early malignancy is problematic, OCT holds great promise in enhancing the diagnostic capability of clinical GI endoscopy.
Zheng, Jun; Yu, Zhiyuan; Xu, Zhao; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-05-12
BACKGROUND Hematoma expansion is associated with poor outcome in intracerebral hemorrhage (ICH) patients. The spot sign and the blend sign are reliable tools for predicting hematoma expansion in ICH patients. The aim of this study was to compare the accuracy of the two signs in the prediction of hematoma expansion. MATERIAL AND METHODS Patients with spontaneous ICH were screened for the presence of the computed tomography angiography (CTA) spot sign and the non-contrast CT (NCCT) blend sign within 6 hours after onset of symptoms. The sensitivity, specificity, and positive and negative predictive values of the spot sign and the blend sign in predicting hematoma expansion were calculated. The accuracy of the spot sign and the blend sign in predicting hematoma expansion was analyzed by receiver-operator analysis. RESULTS A total of 115 patients were enrolled in this study. The spot sign was observed in 25 (21.74%) patients, whereas the blend sign was observed in 22 (19.13%) patients. Of the 28 patients with hematoma expansion, the CTA spot sign was found on admission CT scans in 16 (57.14%) and the NCCT blend sign in 12 (42.86%), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the spot sign for predicting hematoma expansion were 57.14%, 89.66%, 64.00%, and 86.67%, respectively. In contrast, the sensitivity, specificity, positive predictive value, and negative predictive value of the blend sign were 42.86%, 88.51%, 54.55%, and 82.80%, respectively. The area under the curve (AUC) of the spot sign was 0.734, which was higher than that of the blend sign (0.657). CONCLUSIONS Both the spot sign and the blend sign seemed to be good predictors for hematoma expansion, and the spot sign appeared to have better predictive accuracy.
Zheng, Jun; Yu, Zhiyuan; Xu, Zhao; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-01-01
Background Hematoma expansion is associated with poor outcome in intracerebral hemorrhage (ICH) patients. The spot sign and the blend sign are reliable tools for predicting hematoma expansion in ICH patients. The aim of this study was to compare the accuracy of the two signs in the prediction of hematoma expansion. Material/Methods Patients with spontaneous ICH were screened for the presence of the computed tomography angiography (CTA) spot sign and the non-contrast CT (NCCT) blend sign within 6 hours after onset of symptoms. The sensitivity, specificity, and positive and negative predictive values of the spot sign and the blend sign in predicting hematoma expansion were calculated. The accuracy of the spot sign and the blend sign in predicting hematoma expansion was analyzed by receiver-operator analysis. Results A total of 115 patients were enrolled in this study. The spot sign was observed in 25 (21.74%) patients, whereas the blend sign was observed in 22 (19.13%) patients. Of the 28 patients with hematoma expansion, the CTA spot sign was found on admission CT scans in 16 (57.14%) and the NCCT blend sign in 12 (42.86%), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the spot sign for predicting hematoma expansion were 57.14%, 89.66%, 64.00%, and 86.67%, respectively. In contrast, the sensitivity, specificity, positive predictive value, and negative predictive value of the blend sign were 42.86%, 88.51%, 54.55%, and 82.80%, respectively. The area under the curve (AUC) of the spot sign was 0.734, which was higher than that of the blend sign (0.657). Conclusions Both the spot sign and the blend sign seemed to be good predictors for hematoma expansion, and the spot sign appeared to have better predictive accuracy. PMID:28498827
Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen
2016-10-01
To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.
Rath, Timo; Tontini, Gian E; Nägel, Andreas; Vieth, Michael; Zopf, Steffen; Günther, Claudia; Hoffman, Arthur; Neurath, Markus F; Neumann, Helmut
2015-10-22
Distal diminutive colorectal polyps are common and accurate endoscopic prediction of hyperplastic or adenomatous polyp histology could reduce procedural time, costs and potential risks associated with the resection. Within this study we assessed whether digital chromoendoscopy can accurately predict the histology of distal diminutive colorectal polyps according to the ASGE PIVI statement. In this prospective cohort study, 224 consecutive patients undergoing screening or surveillance colonoscopy were included. Real time histology of 121 diminutive distal colorectal polyps was evaluated using high-definition endoscopy with digital chromoendoscopy and the accuracy of predicting histology with digital chromoendoscopy was assessed. The overall accuracy of digital chromoendoscopy for prediction of adenomatous polyp histology was 90.1 %. Sensitivity, specificity, positive and negative predictive values were 93.3, 88.7, 88.7, and 93.2 %, respectively. In high-confidence predictions, the accuracy increased to 96.3 % while sensitivity, specificity, positive and negative predictive values were calculated as 98.1, 94.4, 94.5, and 98.1 %, respectively. Surveillance intervals with digital chromoendoscopy were correctly predicted with >90 % accuracy. High-definition endoscopy in combination with digital chromoendoscopy allowed real-time in vivo prediction of distal colorectal polyp histology and is accurate enough to leave distal colorectal polyps in place without resection or to resect and discard them without pathologic assessment. This approach has the potential to reduce costs and risks associated with the redundant removal of diminutive colorectal polyps. ClinicalTrials NCT02217449.
Happy but overconfident: positive affect leads to inaccurate metacomprehension.
Prinz, Anja; Bergmann, Viktoria; Wittwer, Jörg
2018-05-14
When learning from text, it is important that learners not only comprehend the information provided but also accurately monitor and judge their comprehension, which is known as metacomprehension accuracy. To investigate the role of a learner's affective state for text comprehension and metacomprehension accuracy, we conducted an experiment with N = 103 university students in whom we induced positive, negative, or neutral affect. Positive affect resulted in poorer text comprehension than neutral affect. Positive affect also led to overconfident predictions, whereas negative and neutral affect were both associated with quite accurate predictions. Independent of affect, postdictions were rather underconfident. The results suggest that positive affect bears processing disadvantages for achieving deep comprehension and adequate prediction accuracy. Given that postdictions were more accurate, practice tests might represent an effective instructional method to help learners in a positive affective state to accurately judge their text comprehension.
Raoofi, Z; Barchinegad, M; Haghighi, L
2013-01-01
To evaluate the value of Chlamydia trachomatis antibody testing in prediction of at least one normal tube in infertile women. Eighty infertile women without any history of abdominal or pelvic surgery, pelvic inflammatory disease, and endometriosis were recruited in this cross-sectional study from 2009 to 2010. The patients underwent hysterosalpingography, laparoscopy, and anti Chlamydia trachomatis IgG antibody (CAT) testing. We compared laparoscopy findings and CAT regarding sensitivity, specificity, accuracy, and predicting value of tubal conditions. The CAT was positive in 50 patients (62.5%) and laparoscopy was positive in 32 patients (40%). The CAT was significantly higher in women with tubal disease (1.88 +/- 0.34) versus in women with normal tubes (1.21 +/- 0.28) (p = 0.003). Five out of 30 sero-negative women had unilateral tubal abnormality and none of them had bilateral tubal obstruction or severe pelvic adhesion. The sensitivity, specificity, positive and negative predictive value, and accuracy of the CAT in prediction of one normal tube were 100%, 42.25%, 18%, 100%, and 48.75%, respectively. The negative predictive value of CAT to predict at least one normal tube in infertile women without history of abdominal or pelvic surgery, pelvic inflammatory disease, and endometriosis was 100%.
Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?
Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul
2012-01-01
BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.
EVALUATING RISK-PREDICTION MODELS USING DATA FROM ELECTRONIC HEALTH RECORDS.
Wang, L E; Shaw, Pamela A; Mathelier, Hansie M; Kimmel, Stephen E; French, Benjamin
2016-03-01
The availability of data from electronic health records facilitates the development and evaluation of risk-prediction models, but estimation of prediction accuracy could be limited by outcome misclassification, which can arise if events are not captured. We evaluate the robustness of prediction accuracy summaries, obtained from receiver operating characteristic curves and risk-reclassification methods, if events are not captured (i.e., "false negatives"). We derive estimators for sensitivity and specificity if misclassification is independent of marker values. In simulation studies, we quantify the potential for bias in prediction accuracy summaries if misclassification depends on marker values. We compare the accuracy of alternative prognostic models for 30-day all-cause hospital readmission among 4548 patients discharged from the University of Pennsylvania Health System with a primary diagnosis of heart failure. Simulation studies indicate that if misclassification depends on marker values, then the estimated accuracy improvement is also biased, but the direction of the bias depends on the direction of the association between markers and the probability of misclassification. In our application, 29% of the 1143 readmitted patients were readmitted to a hospital elsewhere in Pennsylvania, which reduced prediction accuracy. Outcome misclassification can result in erroneous conclusions regarding the accuracy of risk-prediction models.
Kim, Min Jung; Kim, Eun-Kyung; Park, Seho; Moon, Hee Jung; Kim, Seung Il; Park, Byeong-Woo
2015-09-01
Triple-negative breast cancer (TNBC) which expresses neither hormonal receptors nor HER-2 is associated with poor prognosis and shorter survival. Several studies have suggested that TNBC patients attaining pathological complete response (pCR) after neoadjuvant chemotherapy (NAC) show a longer survival than those without pCR. To assess the accuracy of 3.0-T breast magnetic resonance imaging (MRI) in predicting pCR and to evaluate the clinicoradiologic factors affecting the diagnostic accuracy of 3.0-T breast MRI in TNBC patients treated with anthracycline and taxane (ACD). This retrospective study was approved by the institutional review board; patient consent was not required. Between 2009 and 2012, 35 TNBC patients with 3.0-T breast MRI prior to (n = 26) or after (n = 35) NAC were included. MRI findings were reviewed according to pCR to chemotherapy. The diagnostic accuracy of 3.0-T breast MRI for predicting pCR and the clinicoradiological factors affecting MRI accuracy and response to NAC were analyzed. 3.0-T MRI following NAC with ACD accurately predicted pCR in 91.4% of TNBC patients. The residual tumor size between pathology and 3.0-T MRI in non-pCR cases showed a higher correlation in the Ki-67-positive TNBC group (r = 0.947) than in the Ki-67 negative group (r = 0.375) with statistical trends (P = 0.069). Pre-treatment MRI in the non-pCR group compared to the pCR group showed a larger tumor size (P = 0.030) and non-mass presentation (P = 0.015). 3.0-T MRI in TNBC patients following NAC with ACD showed a high accuracy for predicting pCR to NAC. Ki-67 can affect the diagnostic accuracy of 3.0-T MRI for pCR to NAC with ACD in TNBC patients. © The Foundation Acta Radiologica 2014.
Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar
2015-01-01
Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055
Reid, S; Lu, C; Hardy, N; Casikar, I; Reid, G; Cario, G; Chou, D; Almashat, D; Condous, G
2014-12-01
To use office gel sonovaginography (SVG) to predict posterior deep infiltrating endometriosis (DIE) in women undergoing laparoscopy. This was a multicenter prospective observational study carried out between January 2009 and February 2013. All women were of reproductive age, had a history of chronic pelvic pain and underwent office gel SVG assessment for the prediction of posterior compartment DIE prior to laparoscopic endometriosis surgery. Gel SVG findings were compared with laparoscopic findings to determine the diagnostic accuracy of office gel SVG for the prediction of posterior compartment DIE. In total, 189 women underwent preoperative gel SVG and laparoscopy for endometriosis. At laparoscopy, 57 (30%) women had posterior DIE and 43 (23%) had rectosigmoid/anterior rectal DIE. For the prediction of rectosigmoid/anterior rectal (i.e. bowel) DIE, gel SVG had an accuracy of 92%, sensitivity of 88%, specificity of 93%, positive predictive value (PPV) of 79%, negative predictive value (NPV) of 97%, positive likelihood ratio (LR+) of 12.9 and negative likelihood ratio (LR-) of 0.12 (P = 3.98E-25); for posterior vaginal wall and rectovaginal septum (RVS) DIE, respectively, the accuracy was 95% and 95%, sensitivity was 18% and 18%, specificity was 99% and 100%, PPV was 67% and 100%, NPV was 95% and 95%, LR+ was 32.4 and infinity and LR- was 0.82 and 0.82 (P = 0.009 and P = 0.003). Office gel SVG appears to be an effective outpatient imaging technique for the prediction of bowel DIE, with a higher accuracy for the prediction of rectosigmoid compared with anterior rectal DIE. Although the sensitivity for vaginal and RVS DIE was limited, gel SVG had a high specificity and NPV for all forms of posterior DIE, indicating that a negative gel SVG examination is highly suggestive of the absence of DIE at laparoscopy. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Heart imaging: the accuracy of the 64-MSCT in the detection of coronary artery disease.
Alessandri, N; Di Matteo, A; Rondoni, G; Petrassi, M; Tufani, F; Ferrari, R; Laghi, A
2009-01-01
At present, coronary angiography represents the gold standard technique for the diagnosis of coronary artery disease. Our aim is to compare the conventional coronary angiography to the coronary 64-multislice spiral computed tomography (64-MSCT), a new and non-invasive cardiac imaging technique. The last generation of MSCT scanners show a better imaging quality, due to a greater spatial and temporal resolution. Four expert observers (two cardiologists and two radiologists) have compared the angiographic data with the accuracy of the 64-MSCT in the detection and evaluation of coronary vessels stenoses. From the data obtained, the sensibility, the specificity and the accuracy of the coronary 64-MSCT have been defined. We have enrolled 75 patients (57 male, 18 female, mean age 61.83 +/- 10.38; range 30-80 years) with known or suspected coronary artery disease. The above population has been divided into 3 groups: Group A (Gr. A) with 40 patients (mean age 60.7 +/- 12.5) affected by both non-significant and significant coronary artery disease; Group B (Gr. B) with 25 patients (mean age 60.3 +/- 14.6) who underwent to percutaneous coronary intervention (PCI); Group C (Gr. C) with 10 patients (mean age 54.20 +/- 13.7) without any coronary angiographic stenoses. All the patients underwent non-invasive exams, conventional coronary angiography and coronary 64-MSCT. The comparison of the data obtained has been carried out according to a per group analysis, per patient analysis and per segment analysis. Moreover, the accuracy of the 64-MSCT has been defined for the detection of >75%, 50-75% and <50% coronary stenoses. Coronary angiography has identified significant coronary artery disease in 75% of the patients in the Gr. A and in 73% of the patients in the Gr. B. No coronary stenoses have been detected in Gr. C. According to a per segment analysis, in Gr. A, 36% of the segments analysed have shown a coronary stenosis (37% stenoses >75%, 32% stenoses 50-75% and 31% stenoses <50%). In Gr. B, 32% of the segments have shown a coronary stenosis (33% stenoses >75%, 29% stenoses 50-75% and 38% stenoses <50%). In-stent disease has been shown in only 4 of the 29 coronary stents identified. In Gr. A, coronary 64-MSCT has confirmed the angiographic results in the 93% of cases (sensibility 93%, specificity 100%, positive predictive value 100% and negative predictive value 83%) while, in Gr. B, this confirm has been obtained only in 64% of cases (sensibility 64%, specificity 100%, positive predictive value 100% and negative predictive value 50%). In Gr. C, we have observed a complete agreement between angiographic and CT data (sensibility, specificity, positive predictive value and negative predictive value 100%). According to a per segment analysis, the angiographic results have been confirmed in 98% of cases in Gr. A (sensibility 98%, specificity 94%, positive predictive value 90% and negative predictive value 94%) but only in 55% of cases in Gr. B (sensibility 55%, specificity 90%, positive predictive value 71% and negative predictive value 81%). Moreover, only 1 of the 4 in-stent restenoses has been detected (sensibility 25%, specificity 100%, positive predictive value 100% and negative predictive value 77%). Coronary angiography has detected a greater number of coronary stenoses than the 64-MSCT. 64-MSCT has demonstrated better accuracy in the study of coronary vessels wider than 2 mm, while its accuracy is lower for smaller vessels (diameter < 2.5 mm) and for the identification of in-stent restenosis, because there is a reduced image quality for these vessels and therefore a lower accuracy in the coronary stenosis detection. Nevertheless, 64-MSCT shows high accuracy and it can be considered a comparative but not a substitutive exam of the coronary angiography. Several technical limitations of the 64-MSCT are responsible of its lower accuracy versus the conventional coronary angiography, but solving these technical problems could give us a new non-invasive imaging technique for the study of coronary stents.
Karzmark, Peter; Deutsch, Gayle K
2018-01-01
This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.
Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio
2014-01-01
To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.
Ratchford, Elizabeth V.; Jin, Zhezhen; Di Tullio, Marco R.; Salameh, Maya J.; Homma, Shunichi; Gan, Robert; Boden-Albala, Bernadette; Sacco, Ralph L.; Rundek, Tatjana
2009-01-01
Objective The prevalence of carotid bruits and the utility of auscultation for predicting carotid stenosis are not well known. We aimed to establish the prevalence of carotid bruits and the diagnostic accuracy of auscultation for detection of hemodynamically significant carotid stenosis, using carotid duplex as the gold standard. Methods The Northern Manhattan Study (NOMAS) is a prospective multiethnic community-based cohort designed to examine the incidence of stroke and other vascular events and the association between various vascular risk factors and subclinical atherosclerosis. Of the stroke-free cohort (n=3298), 686 were examined for carotid bruits and underwent carotid duplex. Main outcome measures included prevalence of carotid bruits and sensitivity, specificity, positive predictive value, negative predictive value and accuracy of auscultation for prediction of ipsilateral carotid stenosis. Results Among 686 subjects with a mean age of 68.2 ± 9.4 years, the prevalence of ≥60% carotid stenosis as detected by ultrasound was 2.2% and the prevalence of carotid bruits was 4.1%. For detection of carotid stenosis, sensitivity of auscultation was 56%, specificity was 98%, positive predictive value was 25%, negative predictive value was 99% and overall accuracy was 97.5%. Discussion In this ethnically diverse cohort, the prevalence of carotid bruits and hemodynamically significant carotid stenosis was low. Sensitivity and positive predictive value were also low, and the 44% false-negative rate suggests that auscultation is not sufficient to exclude carotid stenosis. While the presence of a bruit may still warrant further evaluation with carotid duplex, ultrasonography may be considered in high-risk asymptomatic patients, irrespective of findings on auscultation. PMID:19133168
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tennenberg, S.D.; Jacobs, M.P.; Solomkin, J.S.
1987-04-01
Two methods for predicting adult respiratory distress syndrome (ARDS) were evaluated prospectively in a group of 81 multitrauma and sepsis patients considered at clinical high risk. A popular ARDS risk-scoring method, employing discriminant analysis equations (weighted risk criteria and oxygenation characteristics), yielded a predictive accuracy of 59% and a false-negative rate of 22%. Pulmonary alveolar-capillary permeability (PACP) was determined with a radioaerosol lung-scan technique in 23 of these 81 patients, representing a statistically similar subgroup. Lung scanning achieved a predictive accuracy of 71% (after excluding patients with unilateral pulmonary contusion) and gave no false-negatives. We propose a combination of clinicalmore » risk identification and functional determination of PACP to assess a patient's risk of developing ARDS.« less
Pires, RES; Pereira, AA; Abreu-e-Silva, GM; Labronici, PJ; Figueiredo, LB; Godoy-Santos, AL; Kfuri, M
2014-01-01
Background: Foot and ankle injuries are frequent in emergency departments. Although only a few patients with foot and ankle sprain present fractures and the fracture patterns are almost always simple, lack of fracture diagnosis can lead to poor functional outcomes. Aim: The present study aims to evaluate the reliability of the Ottawa ankle rules and the orthopedic surgeon subjective perception to assess foot and ankle fractures after sprains. Subjects and Methods: A cross-sectional study was conducted from July 2012 to December 2012. Ethical approval was granted. Two hundred seventy-four adult patients admitted to the emergency department with foot and/or ankle sprain were evaluated by an orthopedic surgeon who completed a questionnaire prior to radiographic assessment. The Ottawa ankle rules and subjective perception of foot and/or ankle fractures were evaluated on the questionnaire. Results: Thirteen percent (36/274) patients presented fracture. Orthopedic surgeon subjective analysis showed 55.6% sensitivity, 90.1% specificity, 46.5% positive predictive value and 92.9% negative predictive value. The general orthopedic surgeon opinion accuracy was 85.4%. The Ottawa ankle rules presented 97.2% sensitivity, 7.8% specificity, 13.9% positive predictive value, 95% negative predictive value and 19.9% accuracy respectively. Weight-bearing inability was the Ottawa ankle rule item that presented the highest reliability, 69.4% sensitivity, 61.6% specificity, 63.1% accuracy, 21.9% positive predictive value and 93% negative predictive value respectively. Conclusion: The Ottawa ankle rules showed high reliability for deciding when to take radiographs in foot and/or ankle sprains. Weight-bearing inability was the most important isolated item to predict fracture presence. Orthopedic surgeon subjective analysis to predict fracture possibility showed a high specificity rate, representing a confident method to exclude unnecessary radiographic exams. PMID:24971221
Fayed, Nicolás; Modrego, Pedro J; García-Martí, Gracián; Sanz-Requena, Roberto; Marti-Bonmatí, Luis
2017-05-01
To assess the accuracy of magnetic resonance spectroscopy (1H-MRS) and brain volumetry in mild cognitive impairment (MCI) to predict conversion to probable Alzheimer's disease (AD). Forty-eight patients fulfilling the criteria of amnestic MCI who underwent a conventional magnetic resonance imaging (MRI) followed by MRS, and T1-3D on 1.5 Tesla MR unit. At baseline the patients underwent neuropsychological examination. 1H-MRS of the brain was carried out by exploring the left medial occipital lobe and ventral posterior cingulated cortex (vPCC) using the LCModel software. A high resolution T1-3D sequence was acquired to carry out the volumetric measurement. A cortical and subcortical parcellation strategy was used to obtain the volumes of each area within the brain. The patients were followed up to detect conversion to probable AD. After a 3-year follow-up, 15 (31.2%) patients converted to AD. The myo-inositol in the occipital cortex and glutamate+glutamine (Glx) in the posterior cingulate cortex predicted conversion to probable AD at 46.1% sensitivity and 90.6% specificity. The positive predictive value was 66.7%, and the negative predictive value was 80.6%, with an overall cross-validated classification accuracy of 77.8%. The volume of the third ventricle, the total white matter and entorhinal cortex predict conversion to probable AD at 46.7% sensitivity and 90.9% specificity. The positive predictive value was 70%, and the negative predictive value was 78.9%, with an overall cross-validated classification accuracy of 77.1%. Combining volumetric measures in addition to the MRS measures the prediction to probable AD has a 38.5% sensitivity and 87.5% specificity, with a positive predictive value of 55.6%, a negative predictive value of 77.8% and an overall accuracy of 73.3%. Either MRS or brain volumetric measures are markers separately of cognitive decline and may serve as a noninvasive tool to monitor cognitive changes and progression to dementia in patients with amnestic MCI, but the results do not support the routine use in the clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.
Role of specimen US for predicting resection margin status in breast conserving therapy.
Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G
2015-01-01
To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.
Yu, Zhiyuan; Zheng, Jun; Guo, Rui; Ma, Lu; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-12-01
Hematoma expansion is independently associated with poor outcome in intracerebral hemorrhage (ICH). Blend sign is a simple predictor for hematoma expansion on non-contrast computed tomography. However, its accuracy for predicting hematoma expansion is inconsistent in previous studies. This meta-analysis is aimed to systematically assess the performance of blend sign in predicting hematoma expansion in ICH. A systematic literature search was conducted. Original studies about predictive accuracy of blend sign for hematoma expansion in ICH were included. Pooled sensitivity, specificity, positive and negative likelihood ratios were calculated. Summary receiver operating characteristics curve was constructed. Publication bias was assessed by Deeks' funnel plot asymmetry test. A total of 5 studies with 2248 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive and negative likelihood ratios of blend sign for predicting hematoma expansion were 0.28, 0.92, 3.4 and 0.78, respectively. The area under the curve (AUC) was 0.85. No significant publication bias was found. This meta-analysis demonstrates that blend sign is a useful predictor with high specificity for hematoma expansion in ICH. Further studies with larger sample size are still necessary to verify the accuracy of blend sign for predicting hematoma expansion. Copyright © 2017 Elsevier B.V. All rights reserved.
Noninvasive Electromagnetic Detection of Bladder Cancer
Cormio, Luigi; Vedruccio, Clarbruno; Leucci, Giorgio; Massenio, Paolo; Di Fino, Giuseppe; Cavaliere, Vincenzo; Carrieri, Giuseppe
2014-01-01
Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. PMID:24563795
Should gram stains have a role in diagnosing hip arthroplasty infections?
Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A
2010-09-01
The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
Exfoliative cytology: a helpful tool for the diagnosis of paracoccidioidomycosis.
Cardoso, S V; Moreti, M M; Costa, I M; Loyola, A M
2001-07-01
To describe the main cytological findings associated with smears collected from oral lesions of paracoccidioidomycosis and to appraise the use of cytology as a diagnostic tool for the disease. Cytological smears and biopsies were collected from 40 lesions with a clinical suspicion of paracoccidioidomycosis. Evaluation of the sensitivity, specificity, positive and negative predictive values, accuracy and the positive likeness ratio of the oral smear when compared with the histological diagnosis, was performed. The latter is considered the 'gold standard' for comparison. The main morphological findings were the rounded-shaped, birefringent and multiple-budded fungi, Langhans' giant cells and epithelioid cells. The following associative measures were found: sensitivity, 67.9%; specificity, 91.7%; positive predictive value, 95.0%; negative predictive value, 55.0%; accuracy, 75.0%; and positive likeness ratio, 8.14. The cytological findings of paracoccidioidomycosis are characteristic and cytology is accurate in the diagnosis of the disease. Positive patients should be treated. Negative patients should be submitted to biopsy to confirm or to dismiss the diagnosis of this mycosis.
A Sensitive and Specific Neural Signature for Picture-Induced Negative Affect
Chang, Luke J.; Gianaros, Peter J.; Manuck, Stephen B.; Krishnan, Anjali; Wager, Tor D.
2015-01-01
Neuroimaging has identified many correlates of emotion but has not yet yielded brain representations predictive of the intensity of emotional experiences in individuals. We used machine learning to identify a sensitive and specific signature of emotional responses to aversive images. This signature predicted the intensity of negative emotion in individual participants in cross validation (n =121) and test (n = 61) samples (high–low emotion = 93.5% accuracy). It was unresponsive to physical pain (emotion–pain = 92% discriminative accuracy), demonstrating that it is not a representation of generalized arousal or salience. The signature was comprised of mesoscale patterns spanning multiple cortical and subcortical systems, with no single system necessary or sufficient for predicting experience. Furthermore, it was not reducible to activity in traditional “emotion-related” regions (e.g., amygdala, insula) or resting-state networks (e.g., “salience,” “default mode”). Overall, this work identifies differentiable neural components of negative emotion and pain, providing a basis for new, brain-based taxonomies of affective processes. PMID:26098873
Sakane, Makoto; Hori, Masatoshi; Onishi, Hiromitsu; Tsuboyama, Takahiro; Ota, Takashi; Tatsumi, Mitsuaki; Ueda, Yutaka; Kimura, Toshihiro; Kimura, Tadashi; Tomiyama, Noriyuki
The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically classified into no invasion, shallow (3 mm or less), and more. Two radiologists assessed myometrial invasion on MRI. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values, AUC, and interobserver agreement were analyzed. For assessing myometrial invasion, mean accuracy, sensitivity, specificity, positive predictive values, negative predictive values, and AUC, respectively, were as follows: 63%, 42%, 85%, 79%, 47%, and 0.75. Mean interobserver agreement was fair (k = 0.36). Shallow invasions were underestimated as no invasion on MRI in all 6 cases. Magnetic resonance imaging produced false-negative result on half of patients. The misjudgments tended to happen in patients with shallow invasion.
Khan, Naiman A.; Baym, Carol L.; Monti, Jim M.; Raine, Lauren B.; Drollette, Eric S.; Scudder, Mark R.; Moore, R. Davis; Kramer, Arthur F.; Hillman, Charles H.; Cohen, Neal J.
2014-01-01
Objective To assess associations between adiposity and hippocampal-dependent and hippocampal-independent memory forms among prepubertal children. Study design Prepubertal children (7–9-year-olds, n = 126), classified as non-overweight (<85th %tile BMI-for-age [n = 73]) or overweight/obese (≥85th %tile BMI-for-age [n = 53]), completed relational (hippocampal-dependent) and item (hippocampal-independent) memory tasks, and performance was assessed with both direct (behavioral accuracy) and indirect (preferential disproportionate viewing [PDV]) measures. Adiposity (%whole body fat mass, subcutaneous abdominal adipose tissue, visceral adipose tissue, and total abdominal adipose tissue) was assessed using DXA. Backward regressions identified significant (P <0.05) predictive models of memory performance. Covariates included age, sex, pubertal timing, socioeconomic status, IQ, oxygen consumption (VO2max), and body mass index (BMI) z-score. Results Among overweight/obese children, total abdominal adipose tissue was a significant negative predictor of relational memory behavioral accuracy, and pubertal timing together with socioeconomic status jointly predicted the PDV measure of relational memory. In contrast, among non-overweight children, male sex predicted item memory behavioral accuracy, and a model consisting of socioeconomic status and BMI z-score jointly predicted the PDV measure of relational memory. Conclusions Regional, and not whole body, fat deposition was selectively and negatively associated with hippocampal-dependent relational memory among overweight/obese prepubertal children. PMID:25454939
Khan, Naiman A; Baym, Carol L; Monti, Jim M; Raine, Lauren B; Drollette, Eric S; Scudder, Mark R; Moore, R Davis; Kramer, Arthur F; Hillman, Charles H; Cohen, Neal J
2015-02-01
To assess associations between adiposity and hippocampal-dependent and hippocampal-independent memory forms among prepubertal children. Prepubertal children (age 7-9 years; n = 126), classified as non-overweight (<85th percentile body mass index [BMI]-for-age [n = 73]) or overweight/obese (≥85th percentile BMI-for-age [n = 53]), completed relational (hippocampal-dependent) and item (hippocampal-independent) memory tasks. Performance was assessed with both direct (behavioral accuracy) and indirect (preferential disproportionate viewing [PDV]) measures. Adiposity (ie, percent whole-body fat mass, subcutaneous abdominal adipose tissue, visceral adipose tissue, and total abdominal adipose tissue) was assessed by dual-energy X-ray absorptiometry. Backward regression identified significant (P < .05) predictive models of memory performance. Covariates included age, sex, pubertal timing, socioeconomic status (SES), IQ, oxygen consumption, and BMI z-score. Among overweight/obese children, total abdominal adipose tissue was a significant negative predictor of relational memory behavioral accuracy, and pubertal timing together with SES jointly predicted the PDV measure of relational memory. In contrast, among non-overweight children, male sex predicted item memory behavioral accuracy, and a model consisting of SES and BMI z-score jointly predicted the PDV measure of relational memory. Regional, but not whole-body, fat deposition was selectively and negatively associated with hippocampal-dependent relational memory among overweight/obese prepubertal children. Copyright © 2015 Elsevier Inc. All rights reserved.
PPCM: Combing multiple classifiers to improve protein-protein interaction prediction
Yao, Jianzhuang; Guo, Hong; Yang, Xiaohan
2015-08-01
Determining protein-protein interaction (PPI) in biological systems is of considerable importance, and prediction of PPI has become a popular research area. Although different classifiers have been developed for PPI prediction, no single classifier seems to be able to predict PPI with high confidence. We postulated that by combining individual classifiers the accuracy of PPI prediction could be improved. We developed a method called protein-protein interaction prediction classifiers merger (PPCM), and this method combines output from two PPI prediction tools, GO2PPI and Phyloprof, using Random Forests algorithm. The performance of PPCM was tested by area under the curve (AUC) using anmore » assembled Gold Standard database that contains both positive and negative PPI pairs. Our AUC test showed that PPCM significantly improved the PPI prediction accuracy over the corresponding individual classifiers. We found that additional classifiers incorporated into PPCM could lead to further improvement in the PPI prediction accuracy. Furthermore, cross species PPCM could achieve competitive and even better prediction accuracy compared to the single species PPCM. This study established a robust pipeline for PPI prediction by integrating multiple classifiers using Random Forests algorithm. Ultimately, this pipeline will be useful for predicting PPI in nonmodel species.« less
Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron
2011-06-13
Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.
Administrative database code accuracy did not vary notably with changes in disease prevalence.
van Walraven, Carl; English, Shane; Austin, Peter C
2016-11-01
Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.
Folli, Secondo; Falco, Giuseppe; Mingozzi, Matteo; Buggi, Federico; Curcio, Annalisa; Ferrari, Guglielmo; Taffurelli, Mario; Regolo, Lea; Nanni, Oriana
2016-04-01
Patients with ipsilateral breast tumor recurrence or new ipsilateral primary tumor after previous breast conservative surgery with negative sentinel lymph node biopsy need a new axillary staging procedure. However, the best surgical option, i.e. repeat sentinel lymph node biopsy or axillary lymph node dissection, is still debated. Purpose of the study is to assess the performance of repeat sentinel lymph node biopsy. In a multicenter study, lymph node biopsy completed by back-up axillary lymph node dissection was undertaken for ipsilateral breast tumor recurrence or new ipsilateral primary tumor. Tracer uptake was used to identify and isolate the sentinel lymph node during surgery, and it was classified after staining with hematoxylin and eosin and monoclonal anti-cytokeratin antibodies. Aside from negative predictive value, overall accuracy and false-negative rate of repeat sentinel lymph node biopsy were assessed. A multicenter, prospective study was conducted performing 30 repeat sentinel lymph node biopsy completed by back-up axillary lymph node dissection for ipsilateral breast tumor recurrence or new ipsilateral primary tumor in patients formerly treated with previous breast conservative surgery and negative sentinel lymph node biopsy. Negative predictive value, overall accuracy and false-negative rate of repeat sentinel lymph node biopsy were assessed. Sentinel lymph nodes were mapped in 27 patients out of 30 (90%). Aberrant drainage pathways were observed in one patient (3.7%). Tracer uptake was sufficient to identify and isolate the sentinel lymph node during surgery in 23 cases (76.6%); the patients in whom lymphoscintigraphy failed or no sentinel lymph nodes could be isolated underwent axillary lymph node dissection. The negative predictive value was 95.2%, the accuracy was 95.6% and the false-negative rate was 33%. Repeat sentinel lymph node biopsy is feasible and accurate, with a high negative predictive value. Patients with ipsilateral breast tumor recurrence or new ipsilateral primary tumor after previous breast conservative surgery and negative sentinel lymph node biopsy can be treated with repeat sentinel lymph node biopsy for the axillary staging and can be spared axillary dissection in case of absence of metastases. However, repeat sentinel lymph node biopsy may prove technically impracticable in about one quarter of cases and thus axillary lymph node dissection remains the only viable option in such instance.
Role of specimen US for predicting resection margin status in breast conserving therapy
MOSCHETTA, M.; TELEGRAFO, M.; INTRONA, T.; COI, L.; RELLA, L.; RANIERI, V.; CIRILLI, A.; IANORA, A.A. STABILE; ANGELELLI, G.
2015-01-01
Aim To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. Patients and methods A total of 132 consecutive patients (age range, 34–87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. Results The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Conclusions Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status. PMID:26712255
Doré, Bruce P; Meksin, Robert; Mather, Mara; Hirst, William; Ochsner, Kevin N
2016-06-01
In the aftermath of a national tragedy, important decisions are predicated on judgments of the emotional significance of the tragedy in the present and future. Research in affective forecasting has largely focused on ways in which people fail to make accurate predictions about the nature and duration of feelings experienced in the aftermath of an event. Here we ask a related but understudied question: can people forecast how they will feel in the future about a tragic event that has already occurred? We found that people were strikingly accurate when predicting how they would feel about the September 11 attacks over 1-, 2-, and 7-year prediction intervals. Although people slightly under- or overestimated their future feelings at times, they nonetheless showed high accuracy in forecasting (a) the overall intensity of their future negative emotion, and (b) the relative degree of different types of negative emotion (i.e., sadness, fear, or anger). Using a path model, we found that the relationship between forecasted and actual future emotion was partially mediated by current emotion and remembered emotion. These results extend theories of affective forecasting by showing that emotional responses to an event of ongoing national significance can be predicted with high accuracy, and by identifying current and remembered feelings as independent sources of this accuracy. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Doré, B.P.; Meksin, R.; Mather, M.; Hirst, W.; Ochsner, K.N
2016-01-01
In the aftermath of a national tragedy, important decisions are predicated on judgments of the emotional significance of the tragedy in the present and future. Research in affective forecasting has largely focused on ways in which people fail to make accurate predictions about the nature and duration of feelings experienced in the aftermath of an event. Here we ask a related but understudied question: can people forecast how they will feel in the future about a tragic event that has already occurred? We found that people were strikingly accurate when predicting how they would feel about the September 11 attacks over 1-, 2-, and 7-year prediction intervals. Although people slightly under- or overestimated their future feelings at times, they nonetheless showed high accuracy in forecasting 1) the overall intensity of their future negative emotion, and 2) the relative degree of different types of negative emotion (i.e., sadness, fear, or anger). Using a path model, we found that the relationship between forecasted and actual future emotion was partially mediated by current emotion and remembered emotion. These results extend theories of affective forecasting by showing that emotional responses to an event of ongoing national significance can be predicted with high accuracy, and by identifying current and remembered feelings as independent sources of this accuracy. PMID:27100309
Linear array ultrasonography to stage rectal neoplasias suitable for local treatment.
Ravizza, Davide; Tamayo, Darina; Fiori, Giancarla; Trovato, Cristina; De Roberto, Giuseppe; de Leone, Annalisa; Crosta, Cristiano
2011-08-01
Because of the many therapeutic options available, a reliable staging is crucial for rectal neoplasia management. Adenomas and cancers limited to the submucosa without lymph node involvement may be treated locally. The aim of this study is to evaluate the diagnostic accuracy of endorectal ultrasonography in the staging of neoplasias suitable for local treatment. We considered all patients who underwent endorectal ultrasonography between 2001 and 2010. The study population consisted of 92 patients with 92 neoplasias (68 adenocarcinomas and 24 adenomas). A 5 and 7.5MHz linear array echoendoscope was used. The postoperative histopathologic result was compared with the preoperative staging defined by endorectal ultrasonography. Adenomas and cancers limited to the submucosa were considered together (pT0-1). The sensitivity, specificity, overall accuracy rate, positive predictive value, and negative predictive value of endorectal ultrasonography for pT0-1 were 86%, 95.6%, 91.3%, 94.9% and 88.7%. Those for nodal involvement were 45.4%, 95.5%, 83%, 76.9% and 84%, with 3 false positive results and 12 false negative. For combined pT0-1 and pN0, endorectal ultrasonography showed an 87.5% sensitivity, 95.9% specificity, 92% overall accuracy rate, 94.9% positive predictive value and 90.2% negative predictive value. Endorectal linear array ultrasonography is a reliable tool to detect rectal neoplasias suitable for local treatment. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Improving transmembrane protein consensus topology prediction using inter-helical interaction.
Wang, Han; Zhang, Chao; Shi, Xiaohu; Zhang, Li; Zhou, You
2012-11-01
Alpha helix transmembrane proteins (αTMPs) represent roughly 30% of all open reading frames (ORFs) in a typical genome and are involved in many critical biological processes. Due to the special physicochemical properties, it is hard to crystallize and obtain high resolution structures experimentally, thus, sequence-based topology prediction is highly desirable for the study of transmembrane proteins (TMPs), both in structure prediction and function prediction. Various model-based topology prediction methods have been developed, but the accuracy of those individual predictors remain poor due to the limitation of the methods or the features they used. Thus, the consensus topology prediction method becomes practical for high accuracy applications by combining the advances of the individual predictors. Here, based on the observation that inter-helical interactions are commonly found within the transmembrane helixes (TMHs) and strongly indicate the existence of them, we present a novel consensus topology prediction method for αTMPs, CNTOP, which incorporates four top leading individual topology predictors, and further improves the prediction accuracy by using the predicted inter-helical interactions. The method achieved 87% prediction accuracy based on a benchmark dataset and 78% accuracy based on a non-redundant dataset which is composed of polytopic αTMPs. Our method derives the highest topology accuracy than any other individual predictors and consensus predictors, at the same time, the TMHs are more accurately predicted in their length and locations, where both the false positives (FPs) and the false negatives (FNs) decreased dramatically. The CNTOP is available at: http://ccst.jlu.edu.cn/JCSB/cntop/CNTOP.html. Copyright © 2012 Elsevier B.V. All rights reserved.
Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E
2016-10-01
It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.
Chen, Peng; Li, Jinyan
2010-05-17
Prediction of long-range inter-residue contacts is an important topic in bioinformatics research. It is helpful for determining protein structures, understanding protein foldings, and therefore advancing the annotation of protein functions. In this paper, we propose a novel ensemble of genetic algorithm classifiers (GaCs) to address the long-range contact prediction problem. Our method is based on the key idea called sequence profile centers (SPCs). Each SPC is the average sequence profiles of residue pairs belonging to the same contact class or non-contact class. GaCs train on multiple but different pairs of long-range contact data (positive data) and long-range non-contact data (negative data). The negative data sets, having roughly the same sizes as the positive ones, are constructed by random sampling over the original imbalanced negative data. As a result, about 21.5% long-range contacts are correctly predicted. We also found that the ensemble of GaCs indeed makes an accuracy improvement by around 5.6% over the single GaC. Classifiers with the use of sequence profile centers may advance the long-range contact prediction. In line with this approach, key structural features in proteins would be determined with high efficiency and accuracy.
Intra-Operative Frozen Sections for Ovarian Tumors – A Tertiary Center Experience
Arshad, Nur Zaiti Md; Ng, Beng Kwang; Paiman, Noor Asmaliza Md; Mahdy, Zaleha Abdullah; Noor, Rushdan Mohd
2018-01-01
Background: Accuracy of diagnosis with intra-operative frozen sections is extremely important in the evaluation of ovarian tumors so that appropriate surgical procedures can be selected. Study design: All patients who with intra-operative frozen sections for ovarian masses in a tertiary center over nine years from June 2008 until April 2017 were reviewed. Frozen section diagnosis and final histopathological reports were compared. Main outcome measures: Sensitivity, specificity, positive and negative predictive values of intra-operative frozen section as compared to final histopathological results for ovarian tumors. Results: A total of 92 cases were recruited for final evaluation. The frozen section diagnoses were comparable with the final histopathological reports in 83.7% of cases. The sensitivity, specificity, positive predictive value and negative predictive value for benign and malignant ovarian tumors were 95.6%, 85.1%, 86.0% and 95.2% and 69.2%, 100%, 100% and 89.2% respectively. For borderline ovarian tumors, the sensitivity and specificity were 76.2% and 88.7%, respectively; the positive predictive value was 66.7% and the negative predictive value was 92.7%. Conclusion: The accuracy of intra-operative frozen section diagnoses for ovarian tumors is high and this approach remains a reliable option in assessing ovarian masses intra-operatively. PMID:29373916
Predicting Positive and Negative Relationships in Large Social Networks.
Wang, Guan-Nan; Gao, Hui; Chen, Lian; Mensah, Dennis N A; Fu, Yan
2015-01-01
In a social network, users hold and express positive and negative attitudes (e.g. support/opposition) towards other users. Those attitudes exhibit some kind of binary relationships among the users, which play an important role in social network analysis. However, some of those binary relationships are likely to be latent as the scale of social network increases. The essence of predicting latent binary relationships have recently began to draw researchers' attention. In this paper, we propose a machine learning algorithm for predicting positive and negative relationships in social networks inspired by structural balance theory and social status theory. More specifically, we show that when two users in the network have fewer common neighbors, the prediction accuracy of the relationship between them deteriorates. Accordingly, in the training phase, we propose a segment-based training framework to divide the training data into two subsets according to the number of common neighbors between users, and build a prediction model for each subset based on support vector machine (SVM). Moreover, to deal with large-scale social network data, we employ a sampling strategy that selects small amount of training data while maintaining high accuracy of prediction. We compare our algorithm with traditional algorithms and adaptive boosting of them. Experimental results of typical data sets show that our algorithm can deal with large social networks and consistently outperforms other methods.
Morotti, A; Romero, J M; Jessel, M J; Brouwers, H B; Gupta, R; Schwab, K; Vashkevich, A; Ayres, A; Anderson, C D; Gurol, M E; Viswanathan, A; Greenberg, S M; Rosand, J; Goldstein, J N
2016-05-19
Reduction of CT tube current is an effective strategy to minimize radiation load. However, tube current is also a major determinant of image quality. We investigated the impact of CTA tube current on spot sign detection and diagnostic performance for intracerebral hemorrhage expansion. We retrospectively analyzed a prospectively collected cohort of consecutive patients with primary intracerebral hemorrhage from January 2001 to April 2015 who underwent CTA. The study population was divided into 2 groups according to the median CTA tube current level: low current (<350 mA) and high current (≥350 mA). CTA first-pass readings for spot sign presence were independently analyzed by 2 readers. Baseline and follow-up hematoma volumes were assessed by semiautomated computer-assisted volumetric analysis. Sensitivity, specificity, positive and negative predictive values, and accuracy of spot sign in predicting hematoma expansion were calculated. This study included 709 patients (288 and 421 in the low- and high-current groups, respectively). A higher proportion of low-current scans identified at least 1 spot sign (20.8% versus 14.7%, P = .034), but hematoma expansion frequency was similar in the 2 groups (18.4% versus 16.2%, P = .434). Sensitivity and positive and negative predictive values were not significantly different between the 2 groups. Conversely, high-current scans showed superior specificity (91% versus 84%, P = .015) and overall accuracy (84% versus 77%, P = .038). CTA obtained at high levels of tube current showed better diagnostic accuracy for prediction of hematoma expansion by using spot sign. These findings may have implications for future studies using the CTA spot sign to predict hematoma expansion for clinical trials. © 2016 American Society of Neuroradiology.
Conde-Agudelo, Agustin; Romero, Roberto
2015-12-01
To determine the accuracy of changes in transvaginal sonographic cervical length over time in predicting preterm birth in women with singleton and twin gestations. PubMed, Embase, Cinahl, Lilacs, and Medion (all from inception to June 30, 2015), bibliographies, Google scholar, and conference proceedings. Cohort or cross-sectional studies reporting on the predictive accuracy for preterm birth of changes in cervical length over time. Two reviewers independently selected studies, assessed the risk of bias, and extracted the data. Summary receiver-operating characteristic curves, pooled sensitivities and specificities, and summary likelihood ratios were generated. Fourteen studies met the inclusion criteria, of which 7 provided data on singleton gestations (3374 women) and 8 on twin gestations (1024 women). Among women with singleton gestations, the shortening of cervical length over time had a low predictive accuracy for preterm birth at <37 and <35 weeks of gestation with pooled sensitivities and specificities, and summary positive and negative likelihood ratios ranging from 49% to 74%, 44% to 85%, 1.3 to 4.1, and 0.3 to 0.7, respectively. In women with twin gestations, the shortening of cervical length over time had a low to moderate predictive accuracy for preterm birth at <34, <32, <30, and <28 weeks of gestation with pooled sensitivities and specificities, and summary positive and negative likelihood ratios ranging from 47% to 73%, 84% to 89%, 3.8 to 5.3, and 0.3 to 0.6, respectively. There were no statistically significant differences between the predictive accuracies for preterm birth of cervical length shortening over time and the single initial and/or final cervical length measurement in 8 of 11 studies that provided data for making these comparisons. In the largest and highest-quality study, a single measurement of cervical length obtained at 24 or 28 weeks of gestation was significantly more predictive of preterm birth than any decrease in cervical length between these gestational ages. Change in transvaginal sonographic cervical length over time is not a clinically useful test to predict preterm birth in women with singleton or twin gestations. A single cervical length measurement obtained between 18 and 24 weeks of gestation appears to be a better test to predict preterm birth than changes in cervical length over time. Published by Elsevier Inc.
Ham, Nam Seok; Jang, Jae Young; Ryu, Sung Woo; Kim, Ji Hye; Park, Eui Ju; Lee, Woong Cheul; Shim, Kwang Yeun; Jeong, Soung Won; Kim, Hyun Gun; Lee, Tae Hee; Jeon, Sung Ran; Cho, Jun Hyung; Cho, Joo Young; Jin, So Young; Lee, Ji Sung
2013-11-07
To determine whether magnified observation of short-segment Barrett's esophagus (BE) is useful for the detection of specialized intestinal metaplasia (SIM). Thirty patients with suspected short-segment BE underwent magnifying endoscopy up to × 80. The magnified images were analyzed with respect to their pit-patterns, which were simultaneously classified into five epithelial types [I (small round), II (straight), III (long oval), IV (tubular), V (villous)] by Endo's classification. Then, a 0.5% solution of methylene blue (MB) was sprayed over columnar mucosa. The patterns of the magnified image and MB staining were analyzed. Biopsies were obtained from the regions previously observed by magnifying endoscopy and MB chromoendoscopy. Three of five patients with a type V (villous) epithelial pattern had SIM, whereas 21 patients with a non-type V epithelial patterns did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of pit-patterns in detecting SIM were 100%, 91.3%, 92.3%, 60% and 100%, respectively (P = 0.004). Three of the 12 patients with positive MB staining had SIM, whereas 14 patients with negative MB staining did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MB staining in detecting SIM were 100%, 60.9%, 65.4%, 25% and 100%, respectively (P = 0.085). The specificity and accuracy of pit-pattern evaluation were significantly superior compared with MB staining for detecting SIM by comparison with the exact McNemar's test (P = 0.0391). The magnified observation of a short-segment BE according to the mucosal pattern and its classification can be predictive of SIM.
Pan, Hui; Ba-Thein, William
2018-01-01
Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.
Feyzi, Ali; Rad, Masoud Pezeshki; Ahanchi, Navid; Firoozabadi, Jalil
2015-01-01
Despite the advantages of ultrasound scan, its use as a screening tool in blunt abdominal trauma is controversial. The aim of this study was to evaluate the diagnostic value of early and late ultrasound in patients with blunt abdominal trauma (BAT). In this study which was performed in a level I trauma center, firstly, 2418 patients with BAT had ultrasound (US) examination by two trauma expert radiologists. Results were compared with the best available gold standards such as laparotomy, CT, repeated ultrasound or clinical course follow-up. Then, 400 patients with BAT were examined by a trained residency student. In the first phase, sensitivity, specificity, negative predictive value, positive predictive value and accuracy of ultrasound were 97%, 98.1%, 99.7%, 83% and 98% respectively. In the second phase, they were 97.3%, 97.2%, 97.7%, 96.8% and 97.3% for the early and 98.5%, 97.6%, 98.5%, 97.5% and 98% for the late ultrasound respectively. Results obtained from this study indicate that negative ultrasound findings associated with negative clinical observation virtually exclude abdominal injury, and confirmation by performing other tests is unnecessary. High sensitivity and negative predictive value is achieved if ultrasound is performed by expert trauma radiologist.
Sinha, Dhurjati Prasad; Das, Munna; Banerjee, Amal Kumar; Ahmed, Shageer; Majumdar, Sonali
2008-02-01
Anginal symptoms are less predictive of abnormal coronary anatomy in women. The diagnostic accuracy of exercise treadmill test for obstructive coronary artery disease is less in young and middle aged women. High sensitive C-reactive protein has shown a strong and consistent relationship to the risk of incident cardiovascular events. Carotid intima media thickness is a non-invasive marker of atherosclerosis burden and also predicts prognosis in patients with coronary artery disease. We investigated whether incorporation of high sensitive C-reactive protein and carotid intima media thickness along with exercise stress results improved the predictive accuracy in perimenopausal non-diabetic women subset. Fifty perimenopausal non-diabetic patients (age 45 +/- 7 years) presenting with typical angina were subjected to treadmill test (Bruce protocol). Also carotid artery images at both sides of neck were acquired by B-mode ultrasound and carotid intima media thickness were measured. High sensitive C-reactive protein was measured. Of 50 patients, 22 had a positive exercise stress result. Coronary angiography done in all 50 patients revealed coronary artery disease in 10 patients with positive exercise stress result and in 4 patients with negative exercise stress result. Treadmill exercise stress test had a sensitivity of 71.4%, specificity of 66.7% and a negative predictive accuracy of 85.7% in this study group. High sensitive C-reactive protein in patients with documented coronary artery disease was not significantly different from those without coronary artery disease (4.8 +/- 0.9 mg/l versus 3.9 +/- 1.7 mg/l, p=NS). Also carotid intima media thickness was not significantly different between either of the groups with coronary artery disease positivity and negativity respectively (left: 1.25 +/- 0.55 versus 1.20 +/- 0.51 mm, p=NS; right:1.18 +/- 0.54 versus 1.15 +/- 0.41 mm, p=NS). High sensitive C-reactive protein and carotid intima media thickness were not helpful in further adding to the predictability of coronary artery disease in perimenopausal patients with typical angina as assessed by treadmill exercise stress test.
Quirino, Isabel G; Silva, Jose Maria P; Diniz, Jose S; Lima, Eleonora M; Rocha, Ana Cristina S; Simões e Silva, Ana Cristina; Oliveira, Eduardo A
2011-01-01
The aim of this study was to evaluate the diagnostic accuracy of dimercapto-succinic acid renal scintigraphy and renal ultrasound in identifying high grade vesicoureteral reflux in children after a first episode of urinary tract infection. A total of 533 children following a first urinary tract infection were included in the analysis. Patients were assessed by 3 diagnostic imaging studies, renal ultrasound, dimercapto-succinic acid scan and voiding cystourethrography. The main event of interest was the presence of high grade (III to V) vesicoureteral reflux. The combined and separate diagnostic accuracy of screening methods was assessed by calculation of diagnostic OR, sensitivity, specificity, positive predictive value, negative predictive value and likelihood ratio. A total of 246 patients had reflux, of whom 144 (27%) had high grade (III to V) disease. Sensitivity, negative predictive value and diagnostic OR of ultrasound for high grade reflux were 83.3%, 90.8% and 7.9, respectively. Dimercapto-succinic acid scan had the same sensitivity as ultrasound but a higher negative predictive value (91.7%) and diagnostic OR (10.9). If both tests were analyzed in parallel by using the OR rule, ie a negative diagnosis was established only when both test results were normal, sensitivity increased to 97%, negative predictive value to 97% and diagnostic OR to 25.3. Only 9 children (6.3%) with dilating reflux had an absence of alterations in both tests. Our findings support the idea that ultrasound and dimercapto-succinic acid scan used in combination are reliable predictors of dilating vesicoureteral reflux. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Information Filtering Based on Users' Negative Opinions
NASA Astrophysics Data System (ADS)
Guo, Qiang; Li, Yang; Liu, Jian-Guo
2013-05-01
The process of heat conduction (HC) has recently found application in the information filtering [Zhang et al., Phys. Rev. Lett.99, 154301 (2007)], which is of high diversity but low accuracy. The classical HC model predicts users' potential interested objects based on their interesting objects regardless to the negative opinions. In terms of the users' rating scores, we present an improved user-based HC (UHC) information model by taking into account users' positive and negative opinions. Firstly, the objects rated by users are divided into positive and negative categories, then the predicted interesting and dislike object lists are generated by the UHC model. Finally, the recommendation lists are constructed by filtering out the dislike objects from the interesting lists. By implementing the new model based on nine similarity measures, the experimental results for MovieLens and Netflix datasets show that the new model considering negative opinions could greatly enhance the accuracy, measured by the average ranking score, from 0.049 to 0.036 for Netflix and from 0.1025 to 0.0570 for Movielens dataset, reduced by 26.53% and 44.39%, respectively. Since users prefer to give positive ratings rather than negative ones, the negative opinions contain much more information than the positive ones, the negative opinions, therefore, are very important for understanding users' online collective behaviors and improving the performance of HC model.
Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian
2017-01-01
Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274
Zheng, Leilei; Chai, Hao; Chen, Wanzhen; Yu, Rongrong; He, Wei; Jiang, Zhengyan; Yu, Shaohua; Li, Huichun; Wang, Wei
2011-12-01
Early parental bonding experiences play a role in emotion recognition and expression in later adulthood, and patients with personality disorder frequently experience inappropriate parental bonding styles, therefore the aim of the present study was to explore whether parental bonding style is correlated with recognition of facial emotion in personality disorder patients. The Parental Bonding Instrument (PBI) and the Matsumoto and Ekman Japanese and Caucasian Facial Expressions of Emotion (JACFEE) photo set tests were carried out in 289 participants. Patients scored lower on parental Care but higher on parental Freedom Control and Autonomy Denial subscales, and they displayed less accuracy when recognizing contempt, disgust and happiness than the healthy volunteers. In healthy volunteers, maternal Autonomy Denial significantly predicted accuracy when recognizing fear, and maternal Care predicted the accuracy of recognizing sadness. In patients, paternal Care negatively predicted the accuracy of recognizing anger, paternal Freedom Control predicted the perceived intensity of contempt, maternal Care predicted the accuracy of recognizing sadness, and the intensity of disgust. Parenting bonding styles have an impact on the decoding process and sensitivity when recognizing facial emotions, especially in personality disorder patients. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.
Schaefferkoetter, Joshua D; Carlson, Eric R; Heidel, Robert E
2015-07-01
The present study investigated the performance of cellular metabolism imaging with 2-deoxy-2-((18)F) fluoro-D-glucose (FDG) versus cellular proliferation imaging with 3'-deoxy-3'-((18)F) fluorothymidine (FLT) in the detection of cervical lymph node metastases in oral/head and neck cancer. We conducted a prospective cohort study to assess a head-to-head performance of FLT imaging and clinical FDG imaging for characterizing cervical lymph node metastases in patients with squamous cell carcinoma (SCC) of the oral/head and neck region. The primary predictor variable of the study was the presence of FDG or FLT avidity within the cervical lymph nodes. The primary outcome variable was the histologic presence of metastatic SCC in the cervical lymph nodes. The performance was reported in terms of the sensitivity, specificity, accuracy, and positive and negative predictive values. The overall accuracy for discriminating positive from negative lymph nodes was evaluated as a function of the positron emission tomography (PET) standardized uptake value (SUV). Receiver operating characteristic (ROC) analyses were performed for both tracers. Eleven patients undergoing surgical resection of SCC of the oral/head and neck region underwent preoperative FDG and FLT PET-computed tomography (CT) scans on separate days. The interpretation of the FDG PET-CT imaging resulted in sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 43.2, 99.5, 94.4, 88.9, and 94.7%, respectively. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for FLT PET-CT imaging was 75.7, 99.2, 97.1, 90.3, and 97.7%, respectively. The areas under the curve for the ROC curves were 0.9 and 0.84 for FDG and FLT, respectively. Poor correlation was observed between the SUV for FDG and FLT within the lymph nodes and tumors. FLT showed better overall performance for detecting lymphadenopathy on qualitative assessment within the total nodal population. This notwithstanding, FDG SUV performed better for pathologic discrimination within the visible lymph nodes. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Stachs, A.; Thi, A. Tra-Ha; Dieterich, M.; Stubert, J.; Hartmann, S.; Glass, Ä.; Reimer, T.; Gerber, B.
2015-01-01
Purpose: To evaluate the accuracy of axillary ultrasound (AUS) in detecting nodal metastasis in patients with early-stage breast cancer and to identify AUS features with high predictive power. Materials and Methods: Prospective single-center preliminary study in 105 patients with a primary diagnosis of breast cancer and clinically negative axilla. AUS was performed using a 12 MHz linear-array transducer before ultrasound-guided needle biopsy. Nodal characteristics (shape, longitudinal-transverse [LT] axis ratio, margins, cortical thickness, hyperechoic hilum) were correlated with histopathological nodal status after SLNB or axillary lymph node dissection (ALND). Results: Nodal metastases were present in 42/105 patients (40.0%). Univariate analyses showed that absence of hyperechoic hilum, round shape, LT axis ratio<2, sharp margins and cortical thickness>3 mm were associated with lymph node metastasis. Multivariate logistic regression analysis revealed cortical thickness > 3 mm as an independent predictive parameter for nodal involvement. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 66.7, 74.6, 63.6, 77.0% and 71.4% respectively when cortical thickness > 3 mm was applied as the criterion for AUS positivity. Axillary tumor volume was low in patients with pT1/2 tumors and negative AUS, since only 3.2% of patients had > 2 metastatic lymph nodes. Conclusion: Cortical thickness>3 mm is a reliable predictor of nodal metastatic involvement. Negative AUS does not exclude lymph node metastases, but extensive axillary tumor volume is rare. PMID:27689144
Kiel, Elizabeth J; Buss, Kristin A
2011-10-01
Early social withdrawal and protective parenting predict a host of negative outcomes, warranting examination of their development. Mothers' accurate anticipation of their toddlers' fearfulness may facilitate transactional relations between toddler fearful temperament and protective parenting, leading to these outcomes. Currently, we followed 93 toddlers (42 female; on average 24.76 months) and their mothers (9% underrepresented racial/ethnic backgrounds) over 3 years. We gathered laboratory observation of fearful temperament, maternal protective behavior, and maternal accuracy during toddlerhood and a multi-method assessment of children's social withdrawal and mothers' self-reported protective behavior at kindergarten entry. When mothers displayed higher accuracy, toddler fearful temperament significantly related to concurrent maternal protective behavior and indirectly predicted kindergarten social withdrawal and maternal protective behavior. These results highlight the important role of maternal accuracy in linking fearful temperament and protective parenting, which predict further social withdrawal and protection, and point to toddlerhood for efforts of prevention of anxiety-spectrum outcomes.
Kiel, Elizabeth J.; Buss, Kristin A.
2011-01-01
Early social withdrawal and protective parenting predict a host of negative outcomes, warranting examination of their development. Mothers’ accurate anticipation of their toddlers’ fearfulness may facilitate transactional relations between toddler fearful temperament and protective parenting, leading to these outcomes. Currently, we followed 93 toddlers (42 female; on average 24.76 months) and their mothers (9% underrepresented racial/ethnic backgrounds) over 3 years. We gathered laboratory observation of fearful temperament, maternal protective behavior, and maternal accuracy during toddlerhood and a multi-method assessment of children’s social withdrawal and mothers’ self-reported protective behavior at kindergarten entry. When mothers displayed higher accuracy, toddler fearful temperament significantly related to concurrent maternal protective behavior and indirectly predicted kindergarten social withdrawal and maternal protective behavior. These results highlight the important role of maternal accuracy in linking fearful temperament and protective parenting, which predict further social withdrawal and protection, and point to toddlerhood for efforts of prevention of anxiety-spectrum outcomes. PMID:21537895
Slaghekke, F; Pasman, S; Veujoz, M; Middeldorp, J M; Lewi, L; Devlieger, R; Favre, R; Lopriore, E; Oepkes, D
2015-10-01
To evaluate the diagnostic accuracy of middle cerebral artery peak systolic velocity (MCA-PSV) Doppler measurements in prediction of hemoglobin levels in twin anemia-polycythemia sequence (TAPS). This study involved a consecutive cohort comprising monochorionic twin pregnancies complicated by TAPS managed at three European fetal medicine centers between 2005 and 2013. The accuracy of MCA-PSV, measured immediately prior to fetal hemoglobin (Hb) measurement by fetal or cord blood sampling, for prediction of anemia and polycythemia was assessed using 2 × 2 tables. A total of 116 measurements (74 recorded in donors and 42 in recipients) from 43 twin pregnancies complicated by TAPS were available for analysis. MCA-PSV multiples of the median (MoM) values correlated well with Hb levels (r = - 0.86; P < 0.001). The sensitivity of MCA-PSV ≥ 1.5 MoM to predict severe anemia (Hb deficit > 5 SD below the mean) in TAPS donors was 94% (95% CI, 85-98%); specificity was 74% (95% CI, 62-83%); positive and negative predictive values were 76% (95% CI, 65-85%) and 94% (95% CI, 83-98%), respectively. The sensitivity of MCA-PSV ≤ 1.0 MoM to predict polycythemia (Hb level > 5 SD above the mean) in TAPS recipients was 97% (95% CI, 87-99%); specificity was 96% (95% CI, 89-99%); positive and negative predictive values were 93% (95% CI, 81-97%) and 99% (95% CI, 93-100%), respectively. MCA-PSV measurement has high diagnostic accuracy for predicting abnormal Hb levels in fetuses with TAPS. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Accuracy of ultrasound in the detection of liver fibrosis in chronic viral hepatitis.
D'Onofrio, Mirko; Martone, Enrico; Brunelli, Silvia; Faccioli, Niccolò; Zamboni, Giulia; Zagni, Irene; Fattovich, Giovanna; Pozzi Mucelli, Roberto
2005-10-01
To assess the accuracy of ultrasonography (US) in the identification and grading of hepatic fibrosis in patients afflicted with chronic viral liver disease, compared to histological examination as a gold standard. We prospectively studied 105 patients (32 F, 73 M) affected by chronic viral liver disease in 36 months. Patients were studied with B-mode US and then underwent US-guided liver biopsy. All the patients were studied with conventional US with a Sequoia 512, 6.0 (Acuson, Mountain View CA, USA). We evaluated the following US parameters: liver margins, parenchymal echotexture, portal vein caliber and spleen diameter. The four B-mode US parameters were used for the US grading (from 0 to 4). Scheuer's grading (from 0 to 4) was used for the histological score. Grades 3 and 4 were considered as positive for fibrosis. Sensitivity, specificity, positive and negative predictive values and accuracy were calculated in the case of absence, positivity of one or all the US parameters. The correlation between US and histological scores was evaluated with Spearman's test. At histology seventy-seven patients (73%) had absent grade 0 (1 patient; 1%), low-moderate grade 1 (35 patients; 33%) or grade 2 (41 patients; 39%) liver fibrosis. Twenty-eight patients (27%) had severe grade 3 (16 patients; 15%) or grade 4 (12 patients; 11%) fibrosis. In the case of absence of US parameters sensitivity was 32%, specificity 32%, positive predictive value 15%, negative predictive value 57% and accuracy 32%. In the case of positivity of at least one of the US parameters the values were 68%, 68%, 43%, 84% and 69%. In the case of presence of all the US signs the results were 25%, 100%, 100%, 79% and 80%. None of the 77 patients with a healthy liver or with low-grade fibrosis was positive for all the US parameters. All the patients positive for all of the ultrasonographic parameters had high-grade fibrosis or cirrhosis at liver biopsy. Correlation between B-mode and histological scores was not statistically significant (Rs=0.45; p=0.0001). US identification of liver fibrosis in chronic liver disease is possible with 25% sensitivity, 100% specificity, 100% positive predictive value and 79% negative predictive value, with an 80% diagnostic accuracy.
Bellomo-Brandao, Maria Angela; Andrade, Paula D; Costa, Sandra CB; Escanhoela, Cecilia AF; Vassallo, Jose; Porta, Gilda; De Tommaso, Adriana MA; Hessel, Gabriel
2009-01-01
AIM: To determine cytomegalovirus (CMV) frequency in neonatal intrahepatic cholestasis by serology, histological revision (searching for cytomegalic cells), immunohistochemistry, and polymerase chain reaction (PCR), and to verify the relationships among these methods. METHODS: The study comprised 101 non-consecutive infants submitted for hepatic biopsy between March 1982 and December 2005. Serological results were obtained from the patient’s files and the other methods were performed on paraffin-embedded liver samples from hepatic biopsies. The following statistical measures were calculated: frequency, sensibility, specific positive predictive value, negative predictive value, and accuracy. RESULTS: The frequencies of positive results were as follows: serology, 7/64 (11%); histological revision, 0/84; immunohistochemistry, 1/44 (2%), and PCR, 6/77 (8%). Only one patient had positive immunohistochemical findings and a positive PCR. The following statistical measures were calculated between PCR and serology: sensitivity, 33.3%; specificity, 88.89%; positive predictive value, 28.57%; negative predictive value, 90.91%; and accuracy, 82.35%. CONCLUSION: The frequency of positive CMV varied among the tests. Serology presented the highest positive frequency. When compared to PCR, the sensitivity and positive predictive value of serology were low. PMID:19610143
Accuracy of frozen section in the diagnosis of ovarian tumours.
Toneva, F; Wright, H; Razvi, K
2012-07-01
The purpose of our retrospective study was to assess the accuracy of intraoperative frozen section diagnosis compared to final paraffin diagnosis in ovarian tumours at a gynaecological oncology centre in the UK. We analysed 66 cases and observed that frozen section consultation agreed with final paraffin diagnosis in 59 cases, which provided an accuracy of 89.4%. The overall sensitivity and specificity for all tumours were 85.4% and 100%, respectively. The positive predictive value (PPV) and negative predictive value (NPV) were 100% and 89.4%, respectively. Of the seven cases with discordant results, the majority were large, mucinous tumours, which is in line with previous studies. Our study demonstrated that despite its limitations, intraoperative frozen section has a high accuracy and sensitivity for assessing ovarian tumours; however, care needs to be taken with large, mucinous tumours.
Beaulieu, Jean; Doerksen, Trevor K; MacKay, John; Rainville, André; Bousquet, Jean
2014-12-02
Genomic selection (GS) may improve selection response over conventional pedigree-based selection if markers capture more detailed information than pedigrees in recently domesticated tree species and/or make it more cost effective. Genomic prediction accuracies using 1748 trees and 6932 SNPs representative of as many distinct gene loci were determined for growth and wood traits in white spruce, within and between environments and breeding groups (BG), each with an effective size of Ne ≈ 20. Marker subsets were also tested. Model fits and/or cross-validation (CV) prediction accuracies for ridge regression (RR) and the least absolute shrinkage and selection operator models approached those of pedigree-based models. With strong relatedness between CV sets, prediction accuracies for RR within environment and BG were high for wood (r = 0.71-0.79) and moderately high for growth (r = 0.52-0.69) traits, in line with trends in heritabilities. For both classes of traits, these accuracies achieved between 83% and 92% of those obtained with phenotypes and pedigree information. Prediction into untested environments remained moderately high for wood (r ≥ 0.61) but dropped significantly for growth (r ≥ 0.24) traits, emphasizing the need to phenotype in all test environments and model genotype-by-environment interactions for growth traits. Removing relatedness between CV sets sharply decreased prediction accuracies for all traits and subpopulations, falling near zero between BGs with no known shared ancestry. For marker subsets, similar patterns were observed but with lower prediction accuracies. Given the need for high relatedness between CV sets to obtain good prediction accuracies, we recommend to build GS models for prediction within the same breeding population only. Breeding groups could be merged to build genomic prediction models as long as the total effective population size does not exceed 50 individuals in order to obtain high prediction accuracy such as that obtained in the present study. A number of markers limited to a few hundred would not negatively impact prediction accuracies, but these could decrease more rapidly over generations. The most promising short-term approach for genomic selection would likely be the selection of superior individuals within large full-sib families vegetatively propagated to implement multiclonal forestry.
Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?
Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun
2015-02-01
To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.
Increased genomic prediction accuracy in wheat breeding using a large Australian panel.
Norman, Adam; Taylor, Julian; Tanaka, Emi; Telfer, Paul; Edwards, James; Martinant, Jean-Pierre; Kuchel, Haydn
2017-12-01
Genomic prediction accuracy within a large panel was found to be substantially higher than that previously observed in smaller populations, and also higher than QTL-based prediction. In recent years, genomic selection for wheat breeding has been widely studied, but this has typically been restricted to population sizes under 1000 individuals. To assess its efficacy in germplasm representative of commercial breeding programmes, we used a panel of 10,375 Australian wheat breeding lines to investigate the accuracy of genomic prediction for grain yield, physical grain quality and other physiological traits. To achieve this, the complete panel was phenotyped in a dedicated field trial and genotyped using a custom Axiom TM Affymetrix SNP array. A high-quality consensus map was also constructed, allowing the linkage disequilibrium present in the germplasm to be investigated. Using the complete SNP array, genomic prediction accuracies were found to be substantially higher than those previously observed in smaller populations and also more accurate compared to prediction approaches using a finite number of selected quantitative trait loci. Multi-trait genetic correlations were also assessed at an additive and residual genetic level, identifying a negative genetic correlation between grain yield and protein as well as a positive genetic correlation between grain size and test weight.
Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice
2018-06-01
The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.
Enhancing the Performance of LibSVM Classifier by Kernel F-Score Feature Selection
NASA Astrophysics Data System (ADS)
Sarojini, Balakrishnan; Ramaraj, Narayanasamy; Nickolas, Savarimuthu
Medical Data mining is the search for relationships and patterns within the medical datasets that could provide useful knowledge for effective clinical decisions. The inclusion of irrelevant, redundant and noisy features in the process model results in poor predictive accuracy. Much research work in data mining has gone into improving the predictive accuracy of the classifiers by applying the techniques of feature selection. Feature selection in medical data mining is appreciable as the diagnosis of the disease could be done in this patient-care activity with minimum number of significant features. The objective of this work is to show that selecting the more significant features would improve the performance of the classifier. We empirically evaluate the classification effectiveness of LibSVM classifier on the reduced feature subset of diabetes dataset. The evaluations suggest that the feature subset selected improves the predictive accuracy of the classifier and reduce false negatives and false positives.
Sharp, Adam L; Jones, Jason P; Wu, Ivan; Huynh, Dan; Kocher, Keith E; Shah, Nirav R; Gould, Michael K
2016-04-01
Pneumonia severity tools were primarily developed in cohorts of hospitalized patients, limiting their applicability to the emergency department (ED). We describe current community ED admission practices and examine the accuracy of the CURB-65 to predict 30-day mortality for patients, either discharged or admitted with community-acquired pneumonia (CAP). A retrospective, observational study of adult CAP encounters in 14 community EDs within an integrated healthcare system. We calculated CURB-65 scores for all encounters and described the use of hospitalization, stratified by each score (0-5). We then used each score as a cutoff to calculate sensitivity, specificity, positive predictive value, negative predictive value (NPV), positive likelihood ratios, and negative likelihood ratios for predicting 30-day mortality. The sample included 21,183 ED encounters for CAP (7,952 discharged and 13,231 admitted). The C-statistic describing the accuracy of CURB-65 for predicting 30-day mortality in the full sample was 0.761 (95% confidence interval [CI], 0.747-0.774). The C-statistic was 0.864 (95% CI, 0.821-0.906) among patients discharged from the ED compared with 0.689 (95% CI, 0.672-0.705) among patients who were admitted. Among all ED encounters a CURB-65 threshold of ≥1 was 92.8% sensitive and 38.0% specific for predicting mortality, with a 99.9% NPV. Among all encounters, 62.5% were admitted, including 36.2% of those at lowest risk (CURB-65 = 0). CURB-65 had very good accuracy for predicting 30-day mortality among patients discharged from the ED. This severity tool may help ED providers risk stratify patients to assist with disposition decisions and identify unwarranted variation in patient care. © 2016 by the Society for Academic Emergency Medicine.
Bae, Ji-Hoon; Paik, Nak Hwan; Park, Gyu-Won; Yoon, Jung-Ro; Chae, Dong-Ju; Kwon, Jae Ho; Kim, Jong In; Nha, Kyung-Wook
2013-03-01
The purpose of this study was to determine the accuracy, sensitivity, specificity, and predictive values of a single event of painful popping in the presence of a posterior root tear of the medial meniscus in middle-aged to older Asian patients. We conducted a retrospective review of medical records of 936 patients who underwent arthroscopic surgeries for an isolated medial meniscus tear between January 2000 and December 2010. There were 332 men and 604 women with a mean age of 41 years (range, 25 to 66 years). The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of a painful popping sensation for a posterior root tear of the medial meniscus were calculated. Arthroscopy confirmed the presence of posterior root tears of the medial menisci in 237 of 936 patients (25.3%). A single event of a painful popping sensation was present in 86 of these 936 patients (9.1%). Of these 86 patients with a painful popping sensation, 83 (96.5%) were categorized as having an isolated posterior root tear of the medial meniscus. The positive predictive value of a painful popping sensation in identifying a posterior root tear of the medial meniscus was 96.5%, the negative predictive value was 81.8%, the sensitivity was 35.0%, the specificity was 99.5%, and the diagnostic accuracy was 77.9%. A single event of painful popping can be a highly predictive clinical sign of a posterior root tear of the medial meniscus in the middle-aged to older Asian population. However, it has low sensitivity for the detection of a posterior root tear of the medial meniscus. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Massa, Luiz M; Hoffman, Jeanne M; Cardenas, Diana D
2009-01-01
To determine the validity, accuracy, and predictive value of the signs and symptoms of urinary tract infection (UTI) for individuals with spinal cord injury (SCI) using intermittent catheterization (IC) and the accuracy of individuals with SCI on IC at predicting their own UTI. Prospective cohort based on data from the first 3 months of a 1-year randomized controlled trial to evaluate UTI prevention effectiveness of hydrophilic and standard catheters. Fifty-six community-based individuals on IC. Presence of UTI as defined as bacteriuria with a colony count of at least 10(5) colony-forming units/mL and at least 1 sign or symptom of UTI. Analysis of monthly urine culture and urinalysis data combined with analysis of monthly data collected using a questionnaire that asked subjects to self-report on UTI signs and symptoms and whether or not they felt they had a UTI. Overall, "cloudy urine" had the highest accuracy (83.1%), and "leukocytes in the urine" had the highest sensitivity (82.8%). The highest specificity was for "fever" (99.0%); however, it had a very low sensitivity (6.9%). Subjects were able to predict their own UTI with an accuracy of 66.2%, and the negative predictive value (82.8%) was substantially higher than the positive predictive value (32.6%). The UTI signs and symptoms can predict a UTI more accurately than individual subjects can by using subjective impressions of their own signs and symptoms. Subjects were better at predicting when they did not have a UTI than when they did have a UTI.
Ianniello, Stefania; Di Giacomo, Vincenza; Sessa, Barbara; Miele, Vittorio
2014-09-01
Combined clinical examination and supine chest radiography have shown low accuracy in the assessment of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room. The aim of our study was to evaluate the diagnostic accuracy of extended-focused assessment with sonography in trauma (e-FAST), in the diagnosis of pneumothorax, compared with the results of multidetector computed tomography (MDCT) and of invasive interventions (thoracostomy tube placement). This was a retrospective case series involving 368 consecutive unstable adult patients (273 men and 95 women; average age, 25 years; range, 16-68 years) admitted to our hospital's emergency department between January 2011 and December 2012 for major trauma (Injury Severity Score ≥ 15). We evaluated the accuracy of thoracic ultrasound in the detection of pneumothorax compared with the results of MDCT and invasive interventions (thoracostomy tube placement). Institutional review board approval was obtained prior to commencement of this study. Among the 736 lung fields included in the study, 87 pneumothoraces were detected with thoracic CT scans (23.6%). e-FAST detected 67/87 and missed 20 pneumothoraces (17 mild, 3 moderate). The diagnostic performance of ultrasound was: sensitivity 77% (74% in 2011 and 80% in 2012), specificity 99.8%, positive predictive value 98.5%, negative predictive value 97%, accuracy 97.2% (67 true positive; 668 true negative; 1 false positive; 20 false negative); 17 missed mild pneumothoraces were not immediately life-threatening (thickness less than 5 mm). Thoracic ultrasound (e-FAST) is a rapid and accurate first-line, bedside diagnostic modality for the diagnosis of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tapping, C. R.; Byass, O. R.; Cast, J. E. I., E-mail: james.cast@hey.nhs.uk
Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity wasmore » 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.« less
Bianchi, Lorenzo; Schiavina, Riccardo; Borghesi, Marco; Bianchi, Federico Mineo; Briganti, Alberto; Carini, Marco; Terrone, Carlo; Mottrie, Alex; Gacci, Mauro; Gontero, Paolo; Imbimbo, Ciro; Marchioro, Giansilvio; Milanese, Giulio; Mirone, Vincenzo; Montorsi, Francesco; Morgia, Giuseppe; Novara, Giacomo; Porreca, Angelo; Volpe, Alessandro; Brunocilla, Eugenio
2018-04-06
To assess the predictive accuracy and the clinical value of a recent nomogram predicting cancer-specific mortality-free survival after surgery in pN1 prostate cancer patients through an external validation. We evaluated 518 prostate cancer patients treated with radical prostatectomy and pelvic lymph node dissection with evidence of nodal metastases at final pathology, at 10 tertiary centers. External validation was carried out using regression coefficients of the previously published nomogram. The performance characteristics of the model were assessed by quantifying predictive accuracy, according to the area under the curve in the receiver operating characteristic curve and model calibration. Furthermore, we systematically analyzed the specificity, sensitivity, positive predictive value and negative predictive value for each nomogram-derived probability cut-off. Finally, we implemented decision curve analysis, in order to quantify the nomogram's clinical value in routine practice. External validation showed inferior predictive accuracy as referred to in the internal validation (65.8% vs 83.3%, respectively). The discrimination (area under the curve) of the multivariable model was 66.7% (95% CI 60.1-73.0%) by testing with receiver operating characteristic curve analysis. The calibration plot showed an overestimation throughout the range of predicted cancer-specific mortality-free survival rates probabilities. However, in decision curve analysis, the nomogram's use showed a net benefit when compared with the scenarios of treating all patients or none. In an external setting, the nomogram showed inferior predictive accuracy and suboptimal calibration characteristics as compared to that reported in the original population. However, decision curve analysis showed a clinical net benefit, suggesting a clinical implication to correctly manage pN1 prostate cancer patients after surgery. © 2018 The Japanese Urological Association.
Logan, Kenneth J; Willis, Julie R
2011-12-01
The purpose of this study was to examine the extent to which adults who do not stutter can predict communication-related attitudes of adults who do stutter. 40 participants (mean age of 22.5 years) evaluated speech samples from an adult with mild stuttering and an adult with severe stuttering via audio-only (n=20) or audio-visual (n=20) modes to predict how the adults had responded on the S24 scale of communication attitudes. Participants correctly predicted which speaker had the more favorable S24 score, and the predicted scores were significantly different between the severity conditions. Across the four subgroups, predicted S24 scores differed from actual scores by 4-9 points. Predicted values were greater than the actual values for 3 of 4 subgroups, but still relatively positive in relation to the S24 norm sample. Stimulus presentation mode interacted with stuttering severity to affect prediction accuracy. The participants predicted the speakers' negative self-attributions more accurately than their positive self-attributions. Findings suggest that adults who do not stutter estimate the communication-related attitudes of specific adults who stutter in a manner that is generally accurate, though, in some conditions, somewhat less favorable than the speaker's actual ratings. At a group level, adults who do not stutter demonstrate the ability to discern minimal versus average levels of attitudinal impact for speakers who stutter. The participants' complex prediction patterns are discussed in relation to stereotype accuracy and classic views of negative stereotyping. The reader will be able to (a) summarize main findings on research related to listeners' attitudes toward people who stutter, (b) describe the extent to which people who do not stutter can predict the communication attitudes of people who do stutter; and (c) discuss how findings from the present study relate to previous findings on stereotypes about people who stutter. Copyright © 2011 Elsevier Inc. All rights reserved.
Evaluation of in silico tools to predict the skin sensitization potential of chemicals.
Verheyen, G R; Braeken, E; Van Deun, K; Van Miert, S
2017-01-01
Public domain and commercial in silico tools were compared for their performance in predicting the skin sensitization potential of chemicals. The packages were either statistical based (Vega, CASE Ultra) or rule based (OECD Toolbox, Toxtree, Derek Nexus). In practice, several of these in silico tools are used in gap filling and read-across, but here their use was limited to make predictions based on presence/absence of structural features associated to sensitization. The top 400 ranking substances of the ATSDR 2011 Priority List of Hazardous Substances were selected as a starting point. Experimental information was identified for 160 chemically diverse substances (82 positive and 78 negative). The prediction for skin sensitization potential was compared with the experimental data. Rule-based tools perform slightly better, with accuracies ranging from 0.6 (OECD Toolbox) to 0.78 (Derek Nexus), compared with statistical tools that had accuracies ranging from 0.48 (Vega) to 0.73 (CASE Ultra - LLNA weak model). Combining models increased the performance, with positive and negative predictive values up to 80% and 84%, respectively. However, the number of substances that were predicted positive or negative for skin sensitization in both models was low. Adding more substances to the dataset will increase the confidence in the conclusions reached. The insights obtained in this evaluation are incorporated in a web database www.asopus.weebly.com that provides a potential end user context for the scope and performance of different in silico tools with respect to a common dataset of curated skin sensitization data.
Bulashevska, Alla; Eils, Roland
2006-06-14
The subcellular location of a protein is closely related to its function. It would be worthwhile to develop a method to predict the subcellular location for a given protein when only the amino acid sequence of the protein is known. Although many efforts have been made to predict subcellular location from sequence information only, there is the need for further research to improve the accuracy of prediction. A novel method called HensBC is introduced to predict protein subcellular location. HensBC is a recursive algorithm which constructs a hierarchical ensemble of classifiers. The classifiers used are Bayesian classifiers based on Markov chain models. We tested our method on six various datasets; among them are Gram-negative bacteria dataset, data for discriminating outer membrane proteins and apoptosis proteins dataset. We observed that our method can predict the subcellular location with high accuracy. Another advantage of the proposed method is that it can improve the accuracy of the prediction of some classes with few sequences in training and is therefore useful for datasets with imbalanced distribution of classes. This study introduces an algorithm which uses only the primary sequence of a protein to predict its subcellular location. The proposed recursive scheme represents an interesting methodology for learning and combining classifiers. The method is computationally efficient and competitive with the previously reported approaches in terms of prediction accuracies as empirical results indicate. The code for the software is available upon request.
Comparison between presepsin and procalcitonin in early diagnosis of neonatal sepsis.
Iskandar, Agustin; Arthamin, Maimun Z; Indriana, Kristin; Anshory, Muhammad; Hur, Mina; Di Somma, Salvatore
2018-05-09
Neonatal sepsis remains worldwide one of the leading causes of morbidity and mortality in both term and preterm infants. Lower mortality rates are related to timely diagnostic evaluation and prompt initiation of empiric antibiotic therapy. Blood culture, as gold standard examination for sepsis, has several limitations for early diagnosis, so that sepsis biomarkers could play an important role in this regard. This study was aimed to compare the value of the two biomarkers presepsin and procalcitonin in early diagnosis of neonatal sepsis. This was a prospective cross-sectional study performed, in Saiful Anwar General Hospital Malang, Indonesia, in 51 neonates that fulfill the criteria of systemic inflammatory response syndrome (SIRS) with blood culture as diagnostic gold standard for sepsis. At reviewer operating characteristic (ROC) curve analyses, using a presepsin cutoff of 706,5 pg/mL, the obtained area under the curve (AUCs) were: sensitivity = 85.7%, specificity = 68.8%, positive predictive value = 85.7%, negative predictive value = 68.8%, positive likelihood ratio = 2.75, negative likelihood ratio = 0.21, and accuracy = 80.4%. On the other hand, with a procalcitonin cutoff value of 161.33 pg/mL the obtained AUCs showed: sensitivity = 68.6%, specificity = 62.5%, positive predictive value = 80%, negative predictive value = 47.6%, positive likelihood ratio = 1.83, the odds ratio negative = 0.5, and accuracy = 66.7%. In early diagnosis of neonatal sepsis, compared with procalcitonin, presepsin seems to provide better early diagnostic value with consequent possible faster therapeutical decision making and possible positive impact on outcome of neonates.
Conde-Agudelo, A; Papageorghiou, A T; Kennedy, S H; Villar, J
2013-05-01
Several biomarkers for predicting intrauterine growth restriction (IUGR) have been proposed in recent years. However, the predictive performance of these biomarkers has not been systematically evaluated. To determine the predictive accuracy of novel biomarkers for IUGR in women with singleton gestations. Electronic databases, reference list checking and conference proceedings. Observational studies that evaluated the accuracy of novel biomarkers proposed for predicting IUGR. Data were extracted on characteristics, quality and predictive accuracy from each study to construct 2×2 tables. Summary receiver operating characteristic curves, sensitivities, specificities and likelihood ratios (LRs) were generated. A total of 53 studies, including 39,974 women and evaluating 37 novel biomarkers, fulfilled the inclusion criteria. Overall, the predictive accuracy of angiogenic factors for IUGR was minimal (median pooled positive and negative LRs of 1.7, range 1.0-19.8; and 0.8, range 0.0-1.0, respectively). Two small case-control studies reported high predictive values for placental growth factor and angiopoietin-2 only when IUGR was defined as birthweight centile with clinical or pathological evidence of fetal growth restriction. Biomarkers related to endothelial function/oxidative stress, placental protein/hormone, and others such as serum levels of vitamin D, urinary albumin:creatinine ratio, thyroid function tests and metabolomic profile had low predictive accuracy. None of the novel biomarkers evaluated in this review are sufficiently accurate to recommend their use as predictors of IUGR in routine clinical practice. However, the use of biomarkers in combination with biophysical parameters and maternal characteristics could be more useful and merits further research. © 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.
Accuracy of FDG-PET to diagnose lung cancer in a region of endemic granulomatous disease.
Deppen, Stephen; Putnam, Joe B; Andrade, Gabriela; Speroff, Theodore; Nesbitt, Jonathan C; Lambright, Eric S; Massion, Pierre P; Walker, Ron; Grogan, Eric L
2011-08-01
The 18 F-fluorodeoxyglucose-positron emission tomography (FDG-PET) is used to evaluate suspicious pulmonary lesions due to its diagnostic accuracy. The southeastern United States has a high prevalence of infectious granulomatous lung disease, and the accuracy of FDG-PET may be reduced in this population. We examined the diagnostic accuracy of FDG-PET in patients with known or suspected non-small cell lung cancer treated at our institution. A total of 279 patients, identified through our prospective database, underwent an operation for known or suspected lung cancer. Preoperative FDG-PET in 211 eligible patients was defined by standardized uptake value greater than 2.5 or by description ("moderate" or "intense") as avid. Sensitivity, specificity, positive and negative predictive values, likelihood ratios, and decision diagrams were calculated for FDG-PET in all patients and in patients with indeterminate nodules. In all eligible patients (n=211), sensitivity and specificity of FDG-PET were 92% and 40%, respectively. Positive and negative predictive values were 86% and 55%. Overall FDG-PET accuracy to diagnose lung cancer was 81%. Preoperative positive likelihood ratio for FDG-PET diagnosis of lung cancer in this population was 1.5 compared with previously published values of 7.1. In 113 indeterminate lesions, 65% had lung cancer and the sensitivity and specificity were 89% and 40%, respectively. Twenty-four benign nodules (60%) had false positive FDG-PET scans. Twenty-two of 43 benign nodules (51%) were granulomas. In a region with endemic granulomatous diseases, the specificity of FDG-PET for diagnosis of lung cancer was 40%. Clinical decisions and future clinical predictive models for lung cancer must accommodate regional variation of FDG-PET scan results. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Mallampati test as a predictor of laryngoscopic view.
Adamus, Milan; Fritscherova, Sarka; Hrabalek, Lumir; Gabrhelik, Tomas; Zapletalova, Jana; Janout, Vladimir
2010-12-01
To determine the accuracy of the modified Mallampati test for predicting difficult tracheal intubation. A cross-sectional, clinical, observational, non-blinded study. A quality analysis of anesthetic care. Operating theatres and department of anesthesiology in a university hospital. Following the local ethics committee approval and patients' informed consent to anesthesia, all adult patients (> 18 yrs) presenting for any type of non-emergency surgical procedures under general anesthesia requiring endotracheal intubation were enrolled. Prior to anesthesia, Samsoon and Young's modification of the Mallampati test (modified Mallampati test) was performed. Following induction, the anesthesiologist described the laryngoscopic view using the Cormack-Lehane scale. Classes 3 or 4 of the modified Mallampati test were considered a predictor of difficult intubation. Grades 3 or 4 of the Cormack-Lehane classification of the laryngoscopic view were defined as impaired glottic exposure. The sensitivity, specificity, positive and negative predictive value, relative risk, likelihood ratio and accuracy of the modified Mallampati test were calculated on 2x2 contingency tables. Of the total 1,518 patients enrolled, 48 had difficult intubation (3.2%). We failed to detect as many as 35.4% patients in whom glottis exposure during direct laryngoscopy was inadequate (sensitivity 0.646). Compared to the original article by Mallampati, we found lower specificity (0.824 vs. 0.995), lower positive predictive value (0.107 vs. 0.933), higher negative predictive value (0.986 vs. 0.928), lower likelihood ratio (3.68 vs. 91.0) and accuracy (0.819 vs. 0.929). When used as a single examination, the modified Mallampati test is of limited value in predicting difficult intubation.
A predictive index of axillary nodal involvement in operable breast cancer.
De Laurentiis, M.; Gallo, C.; De Placido, S.; Perrone, F.; Pettinato, G.; Petrella, G.; Carlomagno, C.; Panico, L.; Delrio, P.; Bianco, A. R.
1996-01-01
We investigated the association between pathological characteristics of primary breast cancer and degree of axillary nodal involvement and obtained a predictive index of the latter from the former. In 2076 cases, 17 histological features, including primary tumour and local invasion variables, were recorded. The whole sample was randomly split in a training (75% of cases) and a test sample. Simple and multiple correspondence analysis were used to select the variables to enter in a multinomial logit model to build an index predictive of the degree of nodal involvement. The response variable was axillary nodal status coded in four classes (N0, N1-3, N4-9, N > or = 10). The predictive index was then evaluated by testing goodness-of-fit and classification accuracy. Covariates significantly associated with nodal status were tumour size (P < 0.0001), tumour type (P < 0.0001), type of border (P = 0.048), multicentricity (P = 0.003), invasion of lymphatic and blood vessels (P < 0.0001) and nipple invasion (P = 0.006). Goodness-of-fit was validated by high concordance between observed and expected number of cases in each decile of predicted probability in both training and test samples. Classification accuracy analysis showed that true node-positive cases were well recognised (84.5%), but there was no clear distinction among the classes of node-positive cases. However, 10 year survival analysis showed a superimposible prognostic behaviour between predicted and observed nodal classes. Moreover, misclassified node-negative patients (i.e. those who are predicted positive) showed an outcome closer to patients with 1-3 metastatic nodes than to node-negative ones. In conclusion, the index cannot completely substitute for axillary node information, but it is a predictor of prognosis as accurate as nodal involvement and identifies a subgroup of node-negative patients with unfavourable prognosis. PMID:8630286
Ramieri, Maria Teresa; Marandino, Ferdinando; Visca, Paolo; Salvitti, Tommaso; Gallo, Enzo; Casini, Beatrice; Giordano, Francesca Romana; Frigieri, Claudia; Caterino, Mauro; Carlini, Sandro; Rinaldi, Massimo; Ceribelli, Anna; Pennetti, Annarita; Alò, Pier Luigi; Marino, Mirella; Pescarmona, Edoardo; Filippetti, Massimo
2016-08-01
Conventional transbronchial needle aspiration (c-TBNA) contributed to improve the bronchoscopic examination, allowing to sample lesions located even outside the tracheo-bronchial tree and in the hilo-mediastinal district, both for diagnostic and staging purposes. We have evaluated the sensitivity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of the c-TBNA performed during the 2005-2015 period for suspicious lung neoplasia and/or hilar and mediastinal lymphadenopathy at the Thoracic endoscopy of the Thoracic Surgery Department of the Regina Elena National Cancer Institute, Rome. Data from 273 consecutive patients (205 males and 68 females) were analyzed. Among 158 (58%) adequate specimens, 112 (41%) were neoplastic or contained atypical cells, 46 (17%) were negative or not diagnostic. We considered in the analysis first the overall period; then we compared the findings of the first [2005-2011] and second period [2012-2015] and, finally, only those of adequate specimens. During the overall period, sensibility and accuracy values were respectively of 53% and 63%, in the first period they reached 41% and 53% respectively; in the second period sensibility and accuracy reached 60% and 68%. Considering only the adequate specimens, sensibility and accuracy during the overall period were respectively of 80% and 82%; the values obtained for the first period were 68% and 72%. Finally, in the second period, sensibility reached 86% and accuracy 89%. Carcinoma-subtyping was possible in 112 cases, adenocarcinomas being diagnosed in 50 cases; further, in 30 cases molecular predictive data could be obtained. The c-TBNA proved to be an efficient method for the diagnosis/staging of lung neoplasms and for the diagnosis of mediastinal lymphadenopathy. Endoscopist's skill and technical development, associated to thin-prep cytology and to a rapid on site examination (ROSE), were able to provide by c-TBNA a high diagnostic yield and molecular predictive data in advanced lung carcinomas.
Lung Ultrasound for Diagnosing Pneumothorax in the Critically Ill Neonate.
Raimondi, Francesco; Rodriguez Fanjul, Javier; Aversa, Salvatore; Chirico, Gaetano; Yousef, Nadya; De Luca, Daniele; Corsini, Iuri; Dani, Carlo; Grappone, Lidia; Orfeo, Luigi; Migliaro, Fiorella; Vallone, Gianfranco; Capasso, Letizia
2016-08-01
To evaluate the accuracy of lung ultrasound for the diagnosis of pneumothorax in the sudden decompensating patient. In an international, prospective study, sudden decompensation was defined as a prolonged significant desaturation (oxygen saturation <65% for more than 40 seconds) and bradycardia or sudden increase of oxygen requirement by at least 50% in less than 10 minutes with a final fraction of inspired oxygen ≥0.7 to keep stable saturations. All eligible patients had an ultrasound scan before undergoing a chest radiograph, which was the reference standard. Forty-two infants (birth weight = 1531 ± 812 g; gestational age = 31 ± 3.5 weeks) were enrolled in 6 centers; pneumothorax was detected in 26 (62%). Lung ultrasound accuracy in diagnosing pneumothorax was as follows: sensitivity 100%, specificity 100%, positive predictive value 100%, and negative predictive value 100%. Clinical evaluation of pneumothorax showed sensitivity 84%, specificity 56%, positive predictive value 76%, and negative predictive value 69%. After sudden decompensation, a lung ultrasound scan was performed in an average time of 5.3 ± 5.6 minutes vs 19 ± 11.7 minutes required for a chest radiography. Emergency drainage was performed after an ultrasound scan but before radiography in 9 cases. Lung ultrasound shows high accuracy in detecting pneumothorax in the critical infant, outperforming clinical evaluation and reducing time to imaging diagnosis and drainage. Copyright © 2016 Elsevier Inc. All rights reserved.
3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.
Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G
2006-05-01
This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.
Lee, Jae-Hong; Kim, Do-Hyung; Jeong, Seong-Nyum; Choi, Seong-Ho
2018-04-01
The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.
Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui
2014-01-01
The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.
Omran, Dalia; Zayed, Rania A; Nabeel, Mohammed M; Mobarak, Lamiaa; Zakaria, Zeinab; Farid, Azza; Hassany, Mohamed; Saif, Sameh; Mostafa, Muhammad; Saad, Omar Khalid; Yosry, Ayman
2018-05-01
Stage of liver fibrosis is critical for treatment decision and prediction of outcomes in chronic hepatitis C (CHC) patients. We evaluated the diagnostic accuracy of transient elastography (TE)-FibroScan and noninvasive serum markers tests in the assessment of liver fibrosis in CHC patients, in reference to liver biopsy. One-hundred treatment-naive CHC patients were subjected to liver biopsy, TE-FibroScan, and eight serum biomarkers tests; AST/ALT ratio (AAR), AST to platelet ratio index (APRI), age-platelet index (AP index), fibrosis quotient (FibroQ), fibrosis 4 index (FIB-4), cirrhosis discriminant score (CDS), King score, and Goteborg University Cirrhosis Index (GUCI). Receiver operating characteristic curves were constructed to compare the diagnostic accuracy of these noninvasive methods in predicting significant fibrosis in CHC patients. TE-FibroScan predicted significant fibrosis at cutoff value 8.5 kPa with area under the receiver operating characteristic (AUROC) 0.90, sensitivity 83%, specificity 91.5%, positive predictive value (PPV) 91.2%, and negative predictive value (NPV) 84.4%. Serum biomarkers tests showed that AP index and FibroQ had the highest diagnostic accuracy in predicting significant liver fibrosis at cutoff 4.5 and 2.7, AUROC was 0.8 and 0.8 with sensitivity 73.6% and 73.6%, specificity 70.2% and 68.1%, PPV 71.1% and 69.8%, and NPV 72.9% and 72.3%, respectively. Combined AP index and FibroQ had AUROC 0.83 with sensitivity 73.6%, specificity 80.9%, PPV 79.6%, and NPV 75.7% for predicting significant liver fibrosis. APRI, FIB-4, CDS, King score, and GUCI had intermediate accuracy in predicting significant liver fibrosis with AUROC 0.68, 0.78, 0.74, 0.74, and 0.67, respectively, while AAR had low accuracy in predicting significant liver fibrosis. TE-FibroScan is the most accurate noninvasive alternative to liver biopsy. AP index and FibroQ, either as individual tests or combined, have good accuracy in predicting significant liver fibrosis, and are better combined for higher specificity.
Comparative decision models for anticipating shortage of food grain production in India
NASA Astrophysics Data System (ADS)
Chattopadhyay, Manojit; Mitra, Subrata Kumar
2018-01-01
This paper attempts to predict food shortages in advance from the analysis of rainfall during the monsoon months along with other inputs used for crop production, such as land used for cereal production, percentage of area covered under irrigation and fertiliser use. We used six binary classification data mining models viz., logistic regression, Multilayer Perceptron, kernel lab-Support Vector Machines, linear discriminant analysis, quadratic discriminant analysis and k-Nearest Neighbors Network, and found that linear discriminant analysis and kernel lab-Support Vector Machines are equally suitable for predicting per capita food shortage with 89.69 % accuracy in overall prediction and 92.06 % accuracy in predicting food shortage ( true negative rate). Advance information of food shortage can help policy makers to take remedial measures in order to prevent devastating consequences arising out of food non-availability.
Predictive accuracy of particle filtering in dynamic models supporting outbreak projections.
Safarishahrbijari, Anahita; Teyhouee, Aydin; Waldner, Cheryl; Liu, Juxin; Osgood, Nathaniel D
2017-09-26
While a new generation of computational statistics algorithms and availability of data streams raises the potential for recurrently regrounding dynamic models with incoming observations, the effectiveness of such arrangements can be highly subject to specifics of the configuration (e.g., frequency of sampling and representation of behaviour change), and there has been little attempt to identify effective configurations. Combining dynamic models with particle filtering, we explored a solution focusing on creating quickly formulated models regrounded automatically and recurrently as new data becomes available. Given a latent underlying case count, we assumed that observed incident case counts followed a negative binomial distribution. In accordance with the condensation algorithm, each such observation led to updating of particle weights. We evaluated the effectiveness of various particle filtering configurations against each other and against an approach without particle filtering according to the accuracy of the model in predicting future prevalence, given data to a certain point and a norm-based discrepancy metric. We examined the effectiveness of particle filtering under varying times between observations, negative binomial dispersion parameters, and rates with which the contact rate could evolve. We observed that more frequent observations of empirical data yielded super-linearly improved accuracy in model predictions. We further found that for the data studied here, the most favourable assumptions to make regarding the parameters associated with the negative binomial distribution and changes in contact rate were robust across observation frequency and the observation point in the outbreak. Combining dynamic models with particle filtering can perform well in projecting future evolution of an outbreak. Most importantly, the remarkable improvements in predictive accuracy resulting from more frequent sampling suggest that investments to achieve efficient reporting mechanisms may be more than paid back by improved planning capacity. The robustness of the results on particle filter configuration in this case study suggests that it may be possible to formulate effective standard guidelines and regularized approaches for such techniques in particular epidemiological contexts. Most importantly, the work tentatively suggests potential for health decision makers to secure strong guidance when anticipating outbreak evolution for emerging infectious diseases by combining even very rough models with particle filtering method.
Simulated biologic intelligence used to predict length of stay and survival of burns.
Frye, K E; Izenberg, S D; Williams, M D; Luterman, A
1996-01-01
From July 13, 1988, to May 14, 1995, 1585 patients with burns and no other injuries besides inhalation were treated; 4.5% did not survive. Artificial neural networks were trained on patient presentation data with known outcomes on 90% of the randomized cases. The remaining cases were then used to predict survival and length of stay in cases not trained on. Survival was predicted with more than 98% accuracy and length of stay to within a week with 72% accuracy in these cases. For anatomic area involved by burn, burns involving the feet, scalp, or both had the largest negative effect on the survival prediction. In survivors burns involving the buttocks, transport to this burn center by the military or by helicopter, electrical burns, hot tar burns, and inhalation were associated with increasing the length of stay prediction. Neural networks can be used to accurately predict the clinical outcome of a burn. What factors affect that prediction can be investigated.
Forster, Sarah E; Zirnheld, Patrick; Shekhar, Anantha; Steinhauer, Stuart R; O'Donnell, Brian F; Hetrick, William P
2017-09-01
Signals carried by the mesencephalic dopamine system and conveyed to anterior cingulate cortex are critically implicated in probabilistic reward learning and performance monitoring. A common evaluative mechanism purportedly subserves both functions, giving rise to homologous medial frontal negativities in feedback- and response-locked event-related brain potentials (the feedback-related negativity (FRN) and the error-related negativity (ERN), respectively), reflecting dopamine-dependent prediction error signals to unexpectedly negative events. Consistent with this model, the dopamine receptor antagonist, haloperidol, attenuates the ERN, but effects on FRN have not yet been evaluated. ERN and FRN were recorded during a temporal interval learning task (TILT) following randomized, double-blind administration of haloperidol (3 mg; n = 18), diphenhydramine (an active control for haloperidol; 25 mg; n = 20), or placebo (n = 21) to healthy controls. Centroparietal positivities, the Pe and feedback-locked P300, were also measured and correlations between ERP measures and behavioral indices of learning, overall accuracy, and post-error compensatory behavior were evaluated. We hypothesized that haloperidol would reduce ERN and FRN, but that ERN would uniquely track automatic, error-related performance adjustments, while FRN would be associated with learning and overall accuracy. As predicted, ERN was reduced by haloperidol and in those exhibiting less adaptive post-error performance; however, these effects were limited to ERNs following fast timing errors. In contrast, the FRN was not affected by drug condition, although increased FRN amplitude was associated with improved accuracy. Significant drug effects on centroparietal positivities were also absent. Our results support a functional and neurobiological dissociation between the ERN and FRN.
Negative Example Selection for Protein Function Prediction: The NoGO Database
Youngs, Noah; Penfold-Brown, Duncan; Bonneau, Richard; Shasha, Dennis
2014-01-01
Negative examples – genes that are known not to carry out a given protein function – are rarely recorded in genome and proteome annotation databases, such as the Gene Ontology database. Negative examples are required, however, for several of the most powerful machine learning methods for integrative protein function prediction. Most protein function prediction efforts have relied on a variety of heuristics for the choice of negative examples. Determining the accuracy of methods for negative example prediction is itself a non-trivial task, given that the Open World Assumption as applied to gene annotations rules out many traditional validation metrics. We present a rigorous comparison of these heuristics, utilizing a temporal holdout, and a novel evaluation strategy for negative examples. We add to this comparison several algorithms adapted from Positive-Unlabeled learning scenarios in text-classification, which are the current state of the art methods for generating negative examples in low-density annotation contexts. Lastly, we present two novel algorithms of our own construction, one based on empirical conditional probability, and the other using topic modeling applied to genes and annotations. We demonstrate that our algorithms achieve significantly fewer incorrect negative example predictions than the current state of the art, using multiple benchmarks covering multiple organisms. Our methods may be applied to generate negative examples for any type of method that deals with protein function, and to this end we provide a database of negative examples in several well-studied organisms, for general use (The NoGO database, available at: bonneaulab.bio.nyu.edu/nogo.html). PMID:24922051
LaPrade, Robert F; Ho, Charles P; James, Evan; Crespo, Bernardo; LaPrade, Christopher M; Matheny, Lauren M
2015-01-01
The purpose of this study was to determine the diagnostic accuracy of 3 T MRI, including sensitivity, specificity, negative and positive predictive values, for detection of posterior medial and lateral meniscus root tears and avulsions. All patients who had a 3 T MRI of the knee, followed by arthroscopic surgery, were included in this study. Arthroscopy was considered the gold standard. Meniscus root tears diagnosed at arthroscopy and on MRI were defined as a complete meniscus root detachment within 9 mm of the root. All surgical data were collected prospectively and stored in a data registry. MRI exams were reported prospectively by a musculoskeletal radiologist and reviewed retrospectively. There were 287 consecutive patients (156 males, 131 females; mean age 41.7 years) in this study. Prevalence of meniscus posterior root tears identified at arthroscopy was 9.1, 5.9% for medial and 3.5% for lateral root tears (one patient had both). Sensitivity was 0.770 (95% CI 0.570, 0.901), specificity was 0.729 (95% CI 0.708, 0.741), positive predictive value was 0.220 (95% CI 0.163, 0.257) and negative predictive value was 0.970 (95% CI 0.943, 0.987). For medial root tears, sensitivity was 0.824 (95% CI 0.569, 0.953), specificity was 0.800 (95% CI 0.784, 0.808), positive predictive value was 0.206 (95% CI 0.142, 0.238) and negative predictive value was 0.986 (95% CI 0.967, 0.996). For lateral meniscus posterior root tears, sensitivity was 0.600 (95% CI 0.281, 0.860), specificity was 0.903 (95% CI 0.891, 0.912), positive predictive value was 0.181 (95% CI 0.085, 0.261) and negative predictive value was 0.984 (95% CI 0.972, 0.994). This study demonstrated moderate sensitivity and specificity of 3 T MRI to detect posterior meniscus root tears. The negative predictive value of 3 T MRI to detect posterior meniscus root tears was high; however, the positive predictive value was low. Sensitivity was higher for medial root tears, indicating a higher risk of missing lateral root tears on MRI. Imaging has an important role in identifying meniscus posterior horn root tears; however, some root tears may not be identified until arthroscopy. Prognostic study (diagnostic), Level II.
Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Wehrschuetz, M.; Wehrschuetz, E.; Schuchlenz, H.; Schaffler, G.
2010-01-01
Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a k-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations. PMID:20567636
Infante, Fernando; Espada Vaquero, Mercedes; Bignardi, Tommaso; Lu, Chuan; Testa, Antonia C; Fauchon, David; Epstein, Elisabeth; Leone, Francesco P G; Van den Bosch, Thierry; Martins, Wellington P; Condous, George
2018-06-01
To assess interobserver reproducibility in detecting tubal ectopic pregnancies by reading data sets from 3-dimensional (3D) transvaginal ultrasonography (TVUS) and comparing it with real-time 2-dimensional (2D) TVUS. Images were initially classified as showing pregnancies of unknown location or tubal ectopic pregnancies on real time 2D TVUS by an experienced sonologist, who acquired 5 3D volumes. Data sets were analyzed offline by 5 observers who had to classify each case as ectopic pregnancy or pregnancy of unknown location. The interobserver reproducibility was evaluated by the Fleiss κ statistic. The performance of each observer in predicting ectopic pregnancies was compared to that of the experienced sonologist. Women were followed until they were reclassified as follows: (1) failed pregnancy of unknown location; (2) intrauterine pregnancy; (3) ectopic pregnancy; or (4) persistent pregnancy of unknown location. Sixty-one women were included. The agreement between reading offline 3D data sets and the first real-time 2D TVUS was very good (80%-82%; κ = 0.89). The overall interobserver agreement among observers reading offline 3D data sets was moderate (κ = 0.52). The diagnostic performance of experienced observers reading offline 3D data sets had accuracy of 78.3% to 85.0%, sensitivity of 66.7% to 81.3%, specificity of 79.5% to 88.4%, positive predictive value of 57.1% to 72.2%, and negative predictive value of 87.5% to 91.3%, compared to the experienced sonologist's real-time 2D TVUS: accuracy of 94.5%, sensitivity of 94.4%, specificity of 94.5%, positive predictive value of 85.0%, and negative predictive value of 98.1%. The diagnostic accuracy of 3D TVUS by reading offline data sets for predicting ectopic pregnancies is dependent on experience. Reading only static 3D data sets without clinical information does not match the diagnostic performance of real time 2D TVUS combined with clinical information obtained during the scan. © 2017 by the American Institute of Ultrasound in Medicine.
Social stress reactivity alters reward and punishment learning
Frank, Michael J.; Allen, John J. B.
2011-01-01
To examine how stress affects cognitive functioning, individual differences in trait vulnerability (punishment sensitivity) and state reactivity (negative affect) to social evaluative threat were examined during concurrent reinforcement learning. Lower trait-level punishment sensitivity predicted better reward learning and poorer punishment learning; the opposite pattern was found in more punishment sensitive individuals. Increasing state-level negative affect was directly related to punishment learning accuracy in highly punishment sensitive individuals, but these measures were inversely related in less sensitive individuals. Combined electrophysiological measurement, performance accuracy and computational estimations of learning parameters suggest that trait and state vulnerability to stress alter cortico-striatal functioning during reinforcement learning, possibly mediated via medio-frontal cortical systems. PMID:20453038
Social stress reactivity alters reward and punishment learning.
Cavanagh, James F; Frank, Michael J; Allen, John J B
2011-06-01
To examine how stress affects cognitive functioning, individual differences in trait vulnerability (punishment sensitivity) and state reactivity (negative affect) to social evaluative threat were examined during concurrent reinforcement learning. Lower trait-level punishment sensitivity predicted better reward learning and poorer punishment learning; the opposite pattern was found in more punishment sensitive individuals. Increasing state-level negative affect was directly related to punishment learning accuracy in highly punishment sensitive individuals, but these measures were inversely related in less sensitive individuals. Combined electrophysiological measurement, performance accuracy and computational estimations of learning parameters suggest that trait and state vulnerability to stress alter cortico-striatal functioning during reinforcement learning, possibly mediated via medio-frontal cortical systems.
Guillén-Solà, Anna; Marco, Ester; Martínez-Orfila, Joan; Donaire Mejías, M Fernanda; Depolo Passalacqua, Marina; Duarte, Esther; Escalada, Ferran
2013-01-01
Swallowing disorders affect up to 35-85% of patients with stroke. Dysphagia complications can lead to malnutrition, dehydration, bronchoaspirative pneumonia and death, and have impact on health care costs. To evaluate the clinical screening capacity of the Volume Viscosity Swallow Test (V-VST) for oropharyngeal dysphagia and aspiration in a homogeneous stroke patient sample. Cohort study of 52 stroke patients in a subacute phase. Piecemeal deglutition and oropharyngeal residue were considered signs of impaired efficacy and cough, fall in oxygen saturation and voice changes, signs of impaired safety. Sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratios were calculated for V-VST results and compared with those of videofluoroscopy (VFS), the gold standard for studies on swallowing disorders. The V-VST is a highly sensitive and specific test to detect aspiration with sensitivity of 88.2% and specificity of 71.4%; negative predictive value was 92.6%; accuracy index was 0.74. Sensitivity and specificity for penetration were 34.3% and 70.6%, respectively; accuracy was 32%. The V-VST is low in cost, easy to use and very sensitive, meeting the requirements of oropharyngeal dysphagia and aspiration screening test in subacute stroke patients.
Mao, X W; Yang, J Y; Zheng, X X; Wang, L; Zhu, L; Li, Y; Xiong, H K; Sun, J Y
2017-06-12
Objective: To compare the clinical value of two quantitative methods in analyzing endobronchial ultrasound real-time elastography (EBUS-RTE) images for evaluating intrathoracic lymph nodes. Methods: From January 2014 to April 2014, EBUS-RTE examination was performed in patients who received EBUS-TBNA examination in Shanghai Chest Hospital. Each intrathoracic lymph node had a selected EBUS-RTE image. Stiff area ratio and mean hue value of region of interest (ROI) in each image were calculated respectively. The final diagnosis of lymph node was based on the pathologic/microbiologic results of EBUS-TBNA, pathologic/microbiologic results of other examinations and clinical following-up. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were evaluated for distinguishing malignant and benign lesions. Results: Fifty-six patients and 68 lymph nodes were enrolled in this study, of which 35 lymph nodes were malignant and 33 lymph nodes were benign. The stiff area ratio and mean hue value of benign and malignant lesions were 0.32±0.29, 0.62±0.20 and 109.99±28.13, 141.62±17.52, respectively, and statistical differences were found in both of those two methods ( t =-5.14, P <0.01; t =-5.53, P <0.01). The area under curves was 0.813, 0.814 in stiff area ratio and mean hue value, respectively. The optimal diagnostic cut-off value of stiff area ratio was 0.48, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 82.86%, 81.82%, 82.86%, 81.82% and 82.35%, respectively. The optimal diagnostic cut-off value of mean hue value was 126.28, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 85.71%, 75.76%, 78.95%, 83.33% and 80.88%, respectively. Conclusion: Both the stiff area ratio and mean hue value methods can be used for analyzing EBUS-RTE images quantitatively, having the value of differentiating benign and malignant intrathoracic lymph nodes, and the stiff area ratio is better than the mean hue value between the two methods.
Kassem, T W; Abdelaziz, O; Emad-Eldin, S
2017-10-01
The purpose of this study was to evaluate the clinical utility of 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 FDG) positron emission tomography (PET)/computed tomography (CT) ( 18 F-FDG-PET/CT) in the follow-up of adult patients with soft tissue sarcomas. We prospectively evaluated 37 consecutive patients with known soft tissue sarcoma with 18 F-FDG-PET/CT examination for suspected recurrence of disease. They were 21 men and 16 women with a mean age of 49.6±10.6 (SD) years (range, 34-75years). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 18 F-FDG-PET/CT examination were calculated on a per patient basis. 18 F-FDG-PET/CT showed an overall diagnostic accuracy of 91.8%, sensitivity of 90% and a specificity of 100%. The positive predictive value and negative predictive value were 100 and 70%, respectively. The 18 F-FDG-PET/CT interpretations were correct in 34/37 patients (91.8%). Incorrect interpretations occurred in three patients (8.1%). Reasons for false negative findings were low 18 F-FDG uptake of local recurrence in one patient and low 18 F-FDG uptake of subcentimetric inguinal lymph node metastases. 18 F-FDG-PET/CT has a high diagnostic value in the follow-up of patients with soft tissue sarcoma. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Barrera, Terri L; Szafranski, Derek D; Ratcliff, Chelsea G; Garnaat, Sarah L; Norton, Peter J
2016-03-01
One of the primary differences between Cognitive Behavioral Therapy (CBT) and Acceptance and Commitment Therapy (ACT) for anxiety is the approach to managing negative thoughts. CBT focuses on challenging the accuracy of dysfunctional thoughts through cognitive restructuring exercises, whereas ACT attempts to foster acceptance of such thoughts through cognitive defusion exercises. Previous research suggests that both techniques reduce the distress associated with negative thoughts, though questions remain regarding the benefit of these techniques above and beyond exposure to feared stimuli. In the present study, we conducted a brief experimental intervention to examine the utility of cognitive defusion + in-vivo exposure, cognitive restructuring + in-vivo exposure, and in-vivo exposure alone in reducing the impact of negative thoughts in patients with social anxiety disorder. All participants completed a brief public speaking exposure and those in the cognitive conditions received training in the assigned cognitive technique. Participants returned a week later to complete a second exposure task and self-report measures. All three conditions resulted in similar decreases in discomfort related to negative thoughts. ANOVA models failed to find an interaction between change in accuracy or importance and assignment to condition in predicting decreased distress of negative thoughts. These preliminary results suggest that changes in perceived importance and accuracy of negative thoughts may not be the mechanisms by which cognitive defusion and cognitive restructuring affect distress in the short-term.
Colonic polyps: application value of computer-aided detection in computed tomographic colonography.
Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan
2011-02-01
Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.
Sánchez-Rodríguez, Dolores; Annweiler, Cédric; Ronquillo-Moreno, Natalia; Tortosa-Rodríguez, Andrea; Guillén-Solà, Anna; Vázquez-Ibar, Olga; Escalada, Ferran; Muniesa, Josep M; Marco, Ester
Malnutrition is a prevalent condition related to adverse outcomes in older people. Our aim was to compare the diagnostic capacity of the malnutrition criteria of the European Society of Parenteral and Enteral Nutrition (ESPEN) with other classical diagnostic tools. Cohort study of 102 consecutive in-patients ≥70 years admitted for postacute rehabilitation. Patients were considered malnourished if their Mini-Nutritional Assessment-Short Form (MNA-SF) score was ≤11 and serum albumin <3 mg/dL or MNA-SF ≤ 11, serum albumin <3 mg/dL, and usual clinical signs and symptoms of malnutrition. Sensitivity, specificity, positive and negative predictive values, accuracy likelihood ratios, and kappa values were calculated for both methods: and compared with ESPEN consensus. Of 102 eligible in-patients, 88 fulfilled inclusion criteria and were identified as "at risk" by MNA-SF. Malnutrition diagnosis was confirmed in 11.6% and 10.5% of the patients using classical methods,whereas 19.3% were malnourished according to the ESPEN criteria. Combined with low albumin levels, the diagnosis showed 57.9% sensitivity, 64.5% specificity, 85.9% negative predictive value,0.63 accuracy (fair validity, low range), and kappa index of 0.163 (poor ESPEN agreement). The combination of MNA-SF, low albumin, and clinical malnutrition showed 52.6% sensitivity, 88.3% specificity, 88.3%negative predictive value, and 0.82 accuracy (fair validity, low range), and kappa index of 0.43 (fair ESPEN agreement). Malnutrition was almost twice as prevalent when diagnosed by the ESPEN consensus, compared to classical assessment methods: Classical methods: showed fair validity and poor agreement with the ESPEN consensus in assessing malnutrition in geriatric postacute care. Copyright © 2018 Elsevier B.V. All rights reserved.
Koopmeiners, Joseph S.; Feng, Ziding
2015-01-01
Group sequential testing procedures have been proposed as an approach to conserving resources in biomarker validation studies. Previously, Koopmeiners and Feng (2011) derived the asymptotic properties of the sequential empirical positive predictive value (PPV) and negative predictive value curves, which summarize the predictive accuracy of a continuous marker, under case-control sampling. A limitation of their approach is that the prevalence can not be estimated from a case-control study and must be assumed known. In this manuscript, we consider group sequential testing of the predictive accuracy of a continuous biomarker with unknown prevalence. First, we develop asymptotic theory for the sequential empirical PPV and NPV curves when the prevalence must be estimated, rather than assumed known in a case-control study. We then discuss how our results can be combined with standard group sequential methods to develop group sequential testing procedures and bias-adjusted estimators for the PPV and NPV curve. The small sample properties of the proposed group sequential testing procedures and estimators are evaluated by simulation and we illustrate our approach in the context of a study to validate a novel biomarker for prostate cancer. PMID:26537180
Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A
2017-09-01
The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, P<.05), whereas BS did not predict psychosis beyond mere chance (AUC=0.52, P=.730). Sensitivity and specificity were 0.83 and 0.47 for UHR, and 0.96 and 0.09 for BS. UHR plus BS achieved an AUC=0.66, with sensitivity and specificity of 0.75 and 0.56. In comparison, baseline antipsychotic medication yielded a predictive accuracy of AUC=0.62 (sensitivity=0.42; specificity=0.82). A multivariable prediction model comprising continuous measures of positive symptoms and verbal IQ achieved a substantially improved prognostic accuracy (AUC=0.85; sensitivity=0.86; specificity=0.85; positive predictive value=0.54; negative predictive value=0.97). We showed that BS have no predictive accuracy beyond chance, while UHR criteria poorly predict conversion to psychosis. Combining BS with UHR criteria did not improve the predictive accuracy of UHR alone. In contrast, dimensional measures of both positive symptoms and verbal IQ showed excellent prognostic validity. A critical re-thinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Takenouchi, Osamu; Fukui, Shiho; Okamoto, Kenji; Kurotani, Satoru; Imai, Noriyasu; Fujishiro, Miyuki; Kyotani, Daiki; Kato, Yoshinao; Kasahara, Toshihiko; Fujita, Masaharu; Toyoda, Akemi; Sekiya, Daisuke; Watanabe, Shinichi; Seto, Hirokazu; Hirota, Morihiko; Ashikaga, Takao; Miyazawa, Masaaki
2015-11-01
To develop a testing strategy incorporating the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and DEREK, we created an expanded data set of 139 chemicals (102 sensitizers and 37 non-sensitizers) by combining the existing data set of 101 chemicals through the collaborative projects of Japan Cosmetic Industry Association. Of the additional 38 chemicals, 15 chemicals with relatively low water solubility (log Kow > 3.5) were selected to clarify the limitation of testing strategies regarding the lipophilic chemicals. Predictivities of the h-CLAT, DPRA and DEREK, and the combinations thereof were evaluated by comparison to results of the local lymph node assay. When evaluating 139 chemicals using combinations of three methods based on integrated testing strategy (ITS) concept (ITS-based test battery) and a sequential testing strategy (STS) weighing the predictive performance of the h-CLAT and DPRA, overall similar predictivities were found as before on the 101 chemical data set. An analysis of false negative chemicals suggested a major limitation of our strategies was the testing of low water-soluble chemicals. When excluded the negative results for chemicals with log Kow > 3.5, the sensitivity and accuracy of ITS improved to 97% (91 of 94 chemicals) and 89% (114 of 128). Likewise, the sensitivity and accuracy of STS to 98% (92 of 94) and 85% (111 of 129). Moreover, the ITS and STS also showed good correlation with local lymph node assay on three potency classifications, yielding accuracies of 74% (ITS) and 73% (STS). Thus, the inclusion of log Kow in analysis could give both strategies a higher predictive performance. Copyright © 2015 John Wiley & Sons, Ltd.
Huysal, Kağan; Budak, Yasemin U; Karaca, Ayse Ulusoy; Aydos, Murat; Kahvecioğlu, Serdar; Bulut, Mehtap; Polat, Murat
2013-01-01
Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures. We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semiquantitative urine culture. Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8-65.3), and a negative predictive value (NPV) of 88.8% (95% CI = 85.0-91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test. Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis resuIts do not accurately predict the outcome of culture.
A new self-report inventory of dyslexia for students: criterion and construct validity.
Tamboer, Peter; Vorst, Harrie C M
2015-02-01
The validity of a Dutch self-report inventory of dyslexia was ascertained in two samples of students. Six biographical questions, 20 general language statements and 56 specific language statements were based on dyslexia as a multi-dimensional deficit. Dyslexia and non-dyslexia were assessed with two criteria: identification with test results (Sample 1) and classification using biographical information (both samples). Using discriminant analyses, these criteria were predicted with various groups of statements. All together, 11 discriminant functions were used to estimate classification accuracy of the inventory. In Sample 1, 15 statements predicted the test criterion with classification accuracy of 98%, and 18 statements predicted the biographical criterion with classification accuracy of 97%. In Sample 2, 16 statements predicted the biographical criterion with classification accuracy of 94%. Estimations of positive and negative predictive value were 89% and 99%. Items of various discriminant functions were factor analysed to find characteristic difficulties of students with dyslexia, resulting in a five-factor structure in Sample 1 and a four-factor structure in Sample 2. Answer bias was investigated with measures of internal consistency reliability. Less than 20 self-report items are sufficient to accurately classify students with and without dyslexia. This supports the usefulness of self-assessment of dyslexia as a valid alternative to diagnostic test batteries. Copyright © 2015 John Wiley & Sons, Ltd.
Hyland, Catherine A; Millard, Glenda M; O'Brien, Helen; Schoeman, Elizna M; Lopez, Genghis H; McGowan, Eunike C; Tremellen, Anne; Puddephatt, Rachel; Gaerty, Kirsten; Flower, Robert L; Hyett, Jonathan A; Gardener, Glenn J
2017-12-01
Non-invasive fetal RHD genotyping in Australia to reduce anti-D usage will need to accommodate both prolonged sample transport times and a diverse population demographic harbouring a range of RHD blood group gene variants. We compared RHD genotyping accuracy using two blood sample collection tube types for RhD negative women stratified into deleted RHD gene haplotype and RHD gene variant cohorts. Maternal blood samples were collected into EDTA and cell-free (cf)DNA stabilising (BCT) tubes from two sites, one interstate. Automated DNA extraction and polymerase chain reaction (PCR) were used to amplify RHD exons 5 and 10 and CCR5. Automated analysis flagged maternal RHD variants, which were classified by genotyping. Time between sample collection and processing ranged from 2.9 to 187.5 hours. cfDNA levels increased with time for EDTA (range 0.03-138 ng/μL) but not BCT samples (0.01-3.24 ng/μL). For the 'deleted' cohort (n=647) all fetal RHD genotyping outcomes were concordant, excepting for one unexplained false negative EDTA sample. Matched against cord RhD serology, negative predictive values using BCT and EDTA tubes were 100% and 99.6%, respectively. Positive predictive values were 99.7% for both types. Overall 37.2% of subjects carried an RhD negative baby. The 'variant' cohort (n=15) included one novel RHD and eight hybrid or African pseudogene variants. Review for fetal RHD specific signals, based on one exon, showed three EDTA samples discordant to BCT, attributed to high maternal cfDNA levels arising from prolonged transport times. For the deleted haplotype cohort, fetal RHD genotyping accuracy was comparable for samples collected in EDTA and BCT tubes despite higher cfDNA levels in the EDTA tubes. Capacity to predict fetal RHD genotype for maternal carriers of hybrid or pseudogene RHD variants requires stringent control of cfDNA levels. We conclude that fetal RHD genotyping is feasible in the Australian environment to avoid unnecessary anti-D immunoglobulin prophylaxis. Copyright © 2017. Published by Elsevier B.V.
Accuracy of early DMSA scan for VUR in young children with febrile UTI.
Zhang, Xin; Xu, Hong; Zhou, Lijun; Cao, Qi; Shen, Qian; Sun, Li; Fang, Xiaoyan; Guo, Wei; Zhai, Yihui; Rao, Jia; Pa, Mier; Zhao, Ruifang; Bi, Yunli
2014-01-01
To evaluate the accuracy of an acute (99m)Tc-dimercaptosuccinic acid (DMSA) scan in predicting dilating vesicoureteral reflux (VUR) among young children with a febrile urinary tract infection (UTI). The medical records of children (≤ 2 years of age), presenting with febrile UTI between January 2000 and December 2011, were retrospectively reviewed. A total of 523 children were included in this study, of whom 397 children (75.9%) had abnormal DMSA results and 178 children (34.0%) were identified as VUR on micturating cystourethrography (MCU). Among all the patients, the number of children with dilating VUR was 151 (28.9%). The rate of abnormal results on DMSA for the dilating VUR group was significantly higher than the rates for the non-VUR and low-grade VUR groups (P < .01). In the <6 months age group and ≥ 6 months age group, the sensitivities of DMSA in predicting dilating VUR were 96.15% and 100.0%, respectively, the negative predictive values were 97.26% and 100.0%, respectively, and the negative likelihood ratios were 0.0911 and 0.0000, respectively. For children ≤ 2 years of age with a febrile UTI, an acute DMSA scan is valuable in the exclusion of dilating VUR. The likelihood of the presence of dilating VUR on MCU is rather low when the result of DMSA is negative. DMSA should be conducted to assess the need for an MCU.
Daylami, Rouzbeh; Rogers, Ann M; King, Tonya S; Haluck, Randy S; Shope, Timothy R
2008-01-01
Stricture at the gastrojejunal anastomosis after Roux-en-Y gastric bypass is a significant sequela that often requires intervention. The diagnosis of stricture is usually established by a recognized constellation of symptoms, followed by contrast radiography or endoscopy. The purpose of this report was to evaluate the accuracy of contrast swallow studies in excluding the diagnosis of gastrojejunal stricture. A retrospective analysis of the charts of 119 patients who had undergone laparoscopic Roux-en-Y gastric bypass, representing 41 upper gastrointestinal (GI) swallow studies, was conducted. Of those patients who underwent GI swallow studies, 30 then underwent definitive upper endoscopy to confirm or rule out stricture. The overall sensitivity, specificity, and negative predictive value of the swallow studies were calculated. Of the 30 patients who underwent upper endoscopic examination for symptoms of stricture after laparoscopic gastric bypass, 20 were confirmed to have a stricture. The sensitivity, specificity, and negative predictive value of the upper GI swallow study in this group was 55%, 100%, and 53%, respectively. The demographics of the patients with strictures were similar to those of the study group as a whole. The results of our study have shown that a positive upper GI swallow study is 100% specific for the presence of stricture. However, the sensitivity and negative predictive value of upper GI swallow studies were poor, making this modality unsatisfactory in definitively excluding the diagnosis of gastrojejunal stricture.
Brose, Annette; Schmiedek, Florian; Lövdén, Martin; Lindenberger, Ulman
2012-06-01
Across days, individuals experience varying levels of negative affect, control of attention, and motivation. We investigated whether this intraindividual variability was coupled with daily fluctuations in working memory (WM) performance. In 100 days, 101 younger individuals worked on a spatial N-back task and rated negative affect, control of attention, and motivation. Results showed that individuals differed in how reliably WM performance fluctuated across days, and that subjective experiences were primarily linked to performance accuracy. WM performance was lower on days with higher levels of negative affect, reduced control of attention, and reduced task-related motivation. Thus, variables that were found to predict WM in between-subjects designs showed important relationships to WM at the within-person level. In addition, there was shared predictive variance among predictors of WM. Days with increased negative affect and reduced performance were also days with reduced control of attention and reduced motivation to work on tasks. These findings are in line with proposed mechanisms linking negative affect and cognitive performance.
Knoepke, Julia; Richter, Tobias; Isberner, Maj-Britt; Naumann, Johannes; Neeb, Yvonne; Weinert, Sabine
2017-03-01
Establishing local coherence relations is central to text comprehension. Positive-causal coherence relations link a cause and its consequence, whereas negative-causal coherence relations add a contrastive meaning (negation) to the causal link. According to the cumulative cognitive complexity approach, negative-causal coherence relations are cognitively more complex than positive-causal ones. Therefore, they require greater cognitive effort during text comprehension and are acquired later in language development. The present cross-sectional study tested these predictions for German primary school children from Grades 1 to 4 and adults in reading and listening comprehension. Accuracy data in a semantic verification task support the predictions of the cumulative cognitive complexity approach. Negative-causal coherence relations are cognitively more demanding than positive-causal ones. Moreover, our findings indicate that children's comprehension of negative-causal coherence relations continues to develop throughout the course of primary school. Findings are discussed with respect to the generalizability of the cumulative cognitive complexity approach to German.
Creatinine measurement on dry blood spot sample for chronic kidney disease screening.
Silva, Alan Castro Azevedo E; Gómez, Juan Fidel Bencomo; Lugon, Jocemir Ronaldo; Graciano, Miguel Luis
2016-03-01
Chronic kidney disease (CKD) screening is advisable due to its high morbidity and mortality and is usually performed by sampling blood and urine. Here we present an innovative and simpler method, by measuring creatinine on a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. The creatinine values obtained using both tests and the demographic data of each participant allowed us to determinate the eGFR. The adopted cutoff for CKD was an eGFR < 60 ml/min. Mean age was 57 ± 12 years, 74% were female, 40% white, and 60% non-white. Seventy-six percent were hypertensive, 30% diabetic, 37% had family history of CKD, and 22% of smoking. The BMI was 29.5 ± 6.9 kg/m2, median systolic blood pressure was 125 mmHg (IQR 120-140 mmHg) and median diastolic blood pressure was 80 mmHg (IQR 70-80 mmHg). According to MDRD equation, sensitivity was 96%, specificity 55%, predictive positive value 96%, predictive negative value 55% and accuracy 92%. By the CKD-EPI equation the sensitivity was 94%, specificity 55%, predictive positive value 94%, predictive negative value 55% and accuracy 90%. A Bland and Altman analysis showed a relatively narrow range of creatinine values differences (+ 0.68mg/dl to -0.55mg/dl) inside the ± 1.96 SD, without systematic differences. Measurement of creatinine on dry blood sample is an easily feasible non-invasive diagnostic test with good accuracy that may be useful to screen chronic kidney disease.
Locketz, Garrett D; Li, Peter M M C; Fischbein, Nancy J; Holdsworth, Samantha J; Blevins, Nikolas H
2016-10-01
A method to optimize imaging of cholesteatoma by combining the strengths of available modalities will improve diagnostic accuracy and help to target treatment. To assess whether fusing Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) diffusion-weighted magnetic resonance imaging (DW-MRI) with corresponding temporal bone computed tomography (CT) images could increase cholesteatoma diagnostic and localization accuracy across 6 distinct anatomical regions of the temporal bone. Case series and preliminary technology evaluation of adults with preoperative temporal bone CT and PROPELLER DW-MRI scans who underwent surgery for clinically suggested cholesteatoma at a tertiary academic hospital. When cholesteatoma was encountered surgically, the precise location was recorded in a diagram of the middle ear and mastoid. For each patient, the 3 image data sets (CT, PROPELLER DW-MRI, and CT-MRI fusion) were reviewed in random order for the presence or absence of cholesteatoma by an investigator blinded to operative findings. If cholesteatoma was deemed present on review of each imaging modality, the location of the lesion was mapped presumptively. Image analysis was then compared with surgical findings. Twelve adults (5 women and 7 men; median [range] age, 45.5 [19-77] years) were included. The use of CT-MRI fusion had greater diagnostic sensitivity (0.88 vs 0.75), positive predictive value (0.88 vs 0.86), and negative predictive value (0.75 vs 0.60) than PROPELLER DW-MRI alone. Image fusion also showed increased overall localization accuracy when stratified across 6 distinct anatomical regions of the temporal bone (localization sensitivity and specificity, 0.76 and 0.98 for CT-MRI fusion vs 0.58 and 0.98 for PROPELLER DW-MRI). For PROPELLER DW-MRI, there were 15 true-positive, 45 true-negative, 1 false-positive, and 11 false-negative results; overall accuracy was 0.83. For CT-MRI fusion, there were 20 true-positive, 45 true-negative, 1 false-positive, and 6 false-negative results; overall accuracy was 0.90. The poor anatomical spatial resolution of DW-MRI makes precise localization of cholesteatoma within the middle ear and mastoid a diagnostic challenge. This study suggests that the bony anatomic detail obtained via CT coupled with the excellent sensitivity and specificity of PROPELLER DW-MRI for cholesteatoma can improve both preoperative identification and localization of disease over DW-MRI alone.
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
Devillé, Walter LJM; Yzermans, Joris C; van Duijn, Nico P; Bezemer, P Dick; van der Windt, Daniëlle AWM; Bouter, Lex M
2004-01-01
Background Many studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for the heterogeneity of the dipstick accuracy stimulates an ongoing debate. The objective of the present meta-analysis was to summarise the available evidence on the diagnostic accuracy of the urine dipstick test, taking into account various pre-defined potential sources of heterogeneity. Methods Literature from 1990 through 1999 was searched in Medline and Embase, and by reference tracking. Selected publications should be concerned with the diagnosis of bacteriuria or urinary tract infections, investigate the use of dipstick tests for nitrites and/or leukocyte esterase, and present empirical data. A checklist was used to assess methodological quality. Results 70 publications were included. Accuracy of nitrites was high in pregnant women (Diagnostic Odds Ratio = 165) and elderly people (DOR = 108). Positive predictive values were ≥80% in elderly and in family medicine. Accuracy of leukocyte-esterase was high in studies in urology patients (DOR = 276). Sensitivities were highest in family medicine (86%). Negative predictive values were high in both tests in all patient groups and settings, except for in family medicine. The combination of both test results showed an important increase in sensitivity. Accuracy was high in studies in urology patients (DOR = 52), in children (DOR = 46), and if clinical information was present (DOR = 28). Sensitivity was highest in studies carried out in family medicine (90%). Predictive values of combinations of positive test results were low in all other situations. Conclusions Overall, this review demonstrates that the urine dipstick test alone seems to be useful in all populations to exclude the presence of infection if the results of both nitrites and leukocyte-esterase are negative. Sensitivities of the combination of both tests vary between 68 and 88% in different patient groups, but positive test results have to be confirmed. Although the combination of positive test results is very sensitive in family practice, the usefulness of the dipstick test alone to rule in infection remains doubtful, even with high pre-test probabilities. PMID:15175113
NASA Astrophysics Data System (ADS)
Qiu, Yuchen; Wang, Yunzhi; Yan, Shiju; Tan, Maxine; Cheng, Samuel; Liu, Hong; Zheng, Bin
2016-03-01
In order to establish a new personalized breast cancer screening paradigm, it is critically important to accurately predict the short-term risk of a woman having image-detectable cancer after a negative mammographic screening. In this study, we developed and tested a novel short-term risk assessment model based on deep learning method. During the experiment, a number of 270 "prior" negative screening cases was assembled. In the next sequential ("current") screening mammography, 135 cases were positive and 135 cases remained negative. These cases were randomly divided into a training set with 200 cases and a testing set with 70 cases. A deep learning based computer-aided diagnosis (CAD) scheme was then developed for the risk assessment, which consists of two modules: adaptive feature identification module and risk prediction module. The adaptive feature identification module is composed of three pairs of convolution-max-pooling layers, which contains 20, 10, and 5 feature maps respectively. The risk prediction module is implemented by a multiple layer perception (MLP) classifier, which produces a risk score to predict the likelihood of the woman developing short-term mammography-detectable cancer. The result shows that the new CAD-based risk model yielded a positive predictive value of 69.2% and a negative predictive value of 74.2%, with a total prediction accuracy of 71.4%. This study demonstrated that applying a new deep learning technology may have significant potential to develop a new short-term risk predicting scheme with improved performance in detecting early abnormal symptom from the negative mammograms.
NASA Astrophysics Data System (ADS)
Sanghavi, Foram; Agaian, Sos
2017-05-01
The goal of this paper is to (a) test the nuclei based Computer Aided Cancer Detection system using Human Visual based system on the histopathology images and (b) Compare the results of the proposed system with the Local Binary Pattern and modified Fibonacci -p pattern systems. The system performance is evaluated using different parameters such as accuracy, specificity, sensitivity, positive predictive value, and negative predictive value on 251 prostate histopathology images. The accuracy of 96.69% was observed for cancer detection using the proposed human visual based system compared to 87.42% and 94.70% observed for Local Binary patterns and the modified Fibonacci p patterns.
Assessment of electrocardiographic criteria of left atrial enlargement.
Batra, Mahesh Kumar; Khan, Atif; Farooq, Fawad; Masood, Tariq; Karim, Musa
2018-05-01
Background Left atrial enlargement is considered to be a robust, strong, and widely acceptable indicator of cardiovascular outcomes. Echocardiography is the gold standard for measurement of left atrial size, but electrocardiography can be simple, cost-effective, and noninvasive in clinical practice. This study was undertaken to assess the diagnostic accuracy of an established electrocardiographic criterion for left atrial enlargement, taking 2-dimensional echocardiography as the gold-standard technique. Methods A cross-sectional study was conducted on 146 consecutively selected patients with the complaints of dyspnea and palpitation and with a murmur detected on clinical examination, from September 10, 2016 to February 10, 2017. Electrocardiography and echocardiography were performed in all patients. Patients with a negative P wave terminal force in lead V 1 > 40 ms·mm on electrocardiography or left atrial dimension > 40 mm on echocardiography were classified as having left atrial enlargement. Sensitivity and specificity were calculated to assess the diagnostic accuracy. Results Taking 2-dimensional echocardiography as the gold-standard technique, electrocardiography correctly diagnosed 68 patients as positive for left atrial enlargement and 12 as negative. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of electrocardiography for left atrial enlargement were 54.4%, 57.1%, 88.3%, 17.4%, and 54.8%, respectively. Conclusion The electrocardiogram appears to be a reasonable indicator of left atrial enlargement. In case of nonavailability of echocardiography, electrocardiography can be used for diagnosis of left atrial enlargement.
Coelho, Luiz Gonzaga Vaz; Silva, Arilto Eleutério da; Coelho, Maria Clara de Freitas; Penna, Francisco Guilherme Cancela e; Ferreira, Rafael Otto Antunes; Santa-Cecilia, Elisa Viana
2011-01-01
The standard doses of (13)C-urea in (13)C-urea breath test is 75 mg. To assess the diagnostic accuracy of (13)C-urea breath test containing 25 mg of (13)C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. Two hundred seventy adult patients (96 males, 174 females, median age 41 years) performed the standard (13)C-urea breath test (75 mg (13)C-urea) and repeated the (13)C-urea breath test using only 25 mg of (13)C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. One hundred sixty-one (59.6%) patients were H. pylori negative and 109 (40.4%) were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg (13)C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3) at our setting. Therefore, we obtained to 25 mg (13)C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9), sensitivity 83.5% (95% CI: 75.4-89.3), specificity 99.4% (95% CI: 96.6-99.9), positive predictive value 98.3% (95% CI: 92.4-99.4), and negative predictive value 93.0% (95% CI: 88.6-96.1). Low-dose (13)C-urea breath test (25 mg (13)C-urea) does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of (13)C-urea in the urea breath test.
Palumbo, Barbara; Sivolella, Silvio; Palumbo, Isabella; Buresta, Tommaso; Radicchia, Valentina; Fravolini, Mario L; Ferretti, Francesca; Bellavita, Rita; Mearini, Luigi; Scialpi, Michele; Aristei, Cynthia; Pelliccia, Gianfranco
2016-12-01
Patients with suspected recurrence of prostate cancer undergoing [18F]fluoromethyl choline ([18F]FCH) PET/CT were retrospectively evaluated to investigate the influence of hormonal therapy (HT) in [18F]FCH uptake. [18F]FCH PET/CT was performed in 102 surgically treated patients with suspected recurrence (PSA increase >0.2 ng/mL) of prostate cancer, divided in two groups: under HT (N.=54) and without HT (N.=48) at the time of PET scanning. PET/CT was carried out by an integrated system (Biograph 6, CTI/Siemens, Knoxville, TN, USA) intravenously by administering 4.1 MBq/kg of [18F]FCH to each patient; images were acquired 60 minutes later. On the total number of patients, 66 were found to be true positives (TP), 9 false positives (FP), 5 false negatives (FN) and 22 true negatives (TN), sensitivity to [18F]FCH PET/CT was 93%, specificity 71%, accuracy 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 81%. In the 54 patients under HT, 38 were TP, 6 FP, 3 FN and 7 TN, sensitivity was 93%, specificity 54%, accuracy 83%, PPV 86% and NPV was 70%. In the 48 patients receiving no HT, 28 were TP, 3 FP, 2 FN and 15 TN, sensitivity was 93%, specificity 83%, accuracy 90%, PPV 90% and NPV 88%. A χ2 test showed that sensitivity, accuracy and PPV did not differ among patients with and without HT, while specificity and NPV were significantly lower (P<0.001) in HT treated patients. Sensitivity, accuracy and PPV were similar in patients with and without HT. Specificity and NPV were reduced in patients under HT, but further data are necessary to support if this reduction is casual or related to therapy and it could be confirmed in a larger series of patients.
Jiang, Faming; Huang, Weiwei; Wang, Ye; Tian, Panwen; Chen, Xuerong; Liang, Zongan
2016-01-01
Smear-negative pulmonary tuberculosis (PTB) is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB) staining of needle biopsy lung tissues for patients with suspected smear-negative PTB. Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR). For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination. Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124). Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB) for the diagnosis of smear-negative were 61.7% (82/133), 100% (48/48), 100% (82/82), 48.5% (48/181), and 71.8% (130/181), respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133), 95.8% (46/48), 98.3% (119/121), and 76.7% (46/60), respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181]) than histological acid-fast staining (71.8% [130/181]), P < 0.001. Parallel testing of histological AFB staining and PCR showed the sensitivity, specificity, PPV, NPV, and accuracy to be 94.0% (125/133), 95.8% (46/48), 98.4% (125/127), 85.2% (46/54), and 94.5% (171/181), respectively. Among patients with positive AFB and negative PCR results in lung tissue specimens, two were diagnosed with NTM infections (Mycobacterium avium-intracellulare complex and Mycobacterium kansasii). Nucleic acid amplification testing combined with acid-fast staining in lung biopsy tissues can lead to early and accurate diagnosis in patients with smear-negative pulmonary tuberculosis. For patients with positive histological AFB and negative tuberculous PCR results in lung tissue, NTM infection should be suspected and could be identified by specific probe assays or 16S rRNA sequencing.
Pascoal, Lívia Maia; Lopes, Marcos Venícios de Oliveira; Chaves, Daniel Bruno Resende; Beltrão, Beatriz Amorim; da Silva, Viviane Martins; Monteiro, Flávia Paula Magalhães
2015-01-01
OBJECTIVE: to analyze the accuracy of the defining characteristics of the Impaired gas exchange nursing diagnosis in children with acute respiratory infection. METHOD: open prospective cohort study conducted with 136 children monitored for a consecutive period of at least six days and not more than ten days. An instrument based on the defining characteristics of the Impaired gas exchange diagnosis and on literature addressing pulmonary assessment was used to collect data. The accuracy means of all the defining characteristics under study were computed. RESULTS: the Impaired gas exchange diagnosis was present in 42.6% of the children in the first assessment. Hypoxemia was the characteristic that presented the best measures of accuracy. Abnormal breathing presented high sensitivity, while restlessness, cyanosis, and abnormal skin color showed high specificity. All the characteristics presented negative predictive values of 70% and cyanosis stood out by its high positive predictive value. CONCLUSION: hypoxemia was the defining characteristic that presented the best predictive ability to determine Impaired gas exchange. Studies of this nature enable nurses to minimize variability in clinical situations presented by the patient and to identify more precisely the nursing diagnosis that represents the patient's true clinical condition. PMID:26155010
Practice increases procedural errors after task interruption.
Altmann, Erik M; Hambrick, David Z
2017-05-01
Positive effects of practice are ubiquitous in human performance, but a finding from memory research suggests that negative effects are possible also. The finding is that memory for items on a list depends on the time interval between item presentations. This finding predicts a negative effect of practice on procedural performance under conditions of task interruption. As steps of a procedure are performed more quickly, memory for past performance should become less accurate, increasing the rate of skipped or repeated steps after an interruption. We found this effect, with practice generally improving speed and accuracy, but impairing accuracy after interruptions. The results show that positive effects of practice can interact with architectural constraints on episodic memory to have negative effects on performance. In practical terms, the results suggest that practice can be a risk factor for procedural errors in task environments with a high incidence of task interruption. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Accurate where it counts: Empathic accuracy on conflict and no-conflict days.
Lazarus, Gal; Bar-Kalifa, Eran; Rafaeli, Eshkol
2018-03-01
When we are accurate regarding our partners' negative moods, are we seen as more responsive (and do we see them as such) as a function of the presence/absence of conflict? In 2 daily diary studies, empathic accuracy (EA) was assessed by comparing targets' daily negative moods with perceivers' inferences of these moods. We hypothesized that conflict will be associated with reductions in perceived partner responsiveness (PPR) for both parties; that on no-conflict days, EA will be positively associated with both parties' PPR; that on conflict days, this positive association will be stronger for targets but will become negative for perceivers; and that regardless of conflict, overestimation (vs. underestimation) of negative moods will be tied with higher PPR for targets but with lower PPR for perceivers. Thirty-six (Sample 1) and 77 (Sample 2) committed couples completed daily diaries (for 21 or 35 days, respectively). We utilized multilevel polynomial regression with response surface analyses, a sophisticated approach for studying multisource data of this sort (Edwards & Parry, 1993). Results partially supported our hypotheses: conflict was tied to reduced PPR; on no-conflict days, EA was not consistently predictive of target or perceiver PPR; on conflict days, EA predicted increased target PPR but decreased perceiver PPR; finally, overestimation predicted increased target PPR on no-conflict days and decreased perceiver PPR regardless of conflict. These results highlight the double-edged effects of EA on conflict days, and the importance of investigating dyadic EA in a context-sensitive approach. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Vickers, Andrew J.; Wolters, Tineke; Savage, Caroline J.; Cronin, Angel M.; O’Brien, M. Frank; Roobol, Monique J.; Aus, Gunnar; Scardino, Peter T.; Hugosson, Jonas; Schröder, Fritz H.; Lilja, Hans
2012-01-01
Purpose Prostate specific antigen (PSA) velocity has been proposed as a marker to aid detection of prostate cancer. We sought to determine whether PSA velocity could predict the results of repeat biopsy in men with persistently elevated PSA after initial negative biopsy. Materials and Methods We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer (ERSPC), and who had one or more subsequent prostate biopsies after an initial negative finding. We evaluated whether PSA velocity improved predictive accuracy beyond that of PSA alone. Results There were a total of 2579 repeat biopsies, of which 363 (14%) were positive for prostate cancer, and 44 (1.7%) were high grade (Gleason score ≥7). Although PSA velocity was statistically associated with cancer risk (p<0.001), it had very low predictive accuracy (area-under-the-curve [AUC] of 0.55). There was some evidence that PSA velocity improved AUC compared to PSA for high grade cancer. However, the small increase in risk associated with high PSA velocity – from 1.7 % to 2.8% as velocity increased from 0 to 1 ng / ml / year - is of questionable clinical relevance. Conclusions Men with a prior negative biopsy have a lower risk for prostate cancer at subsequent biopsies, with high grade disease particularly rare. We found little evidence to support the use of PSA velocity to aid decisions about repeat biopsy for prostate cancer. PMID:20643434
Vickers, Andrew J; Wolters, Tineke; Savage, Caroline J; Cronin, Angel M; O'Brien, M Frank; Roobol, Monique J; Aus, Gunnar; Scardino, Peter T; Hugosson, Jonas; Schröder, Fritz H; Lilja, Hans
2010-09-01
Prostate specific antigen velocity has been proposed as a marker to aid in prostate cancer detection. We determined whether prostate specific antigen velocity could predict repeat biopsy results in men with persistently increased prostate specific antigen after initial negative biopsy. We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer and who underwent 1 or more subsequent prostate biopsies after an initial negative finding. We evaluated whether prostate specific antigen velocity improved predictive accuracy beyond that of prostate specific antigen alone. Of the 2,579 repeat biopsies 363 (14%) were positive for prostate cancer, of which 44 (1.7%) were high grade (Gleason score 7 or greater). Prostate specific antigen velocity was statistically associated with cancer risk but had low predictive accuracy (AUC 0.55, p <0.001). There was some evidence that prostate specific antigen velocity improved AUC compared to prostate specific antigen for high grade cancer. However, the small increase in risk associated with high prostate specific antigen velocity (from 1.7% to 2.8% as velocity increased from 0 to 1 ng/ml per year) had questionable clinical relevance. Men with prior negative biopsy are at lower risk for prostate cancer at subsequent biopsies with high grade disease particularly rare. We found little evidence to support prostate specific antigen velocity to aid in decisions about repeat biopsy for prostate cancer. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Fazel, Seena; Singh, Jay P; Doll, Helen; Grann, Martin
2012-07-24
To investigate the predictive validity of tools commonly used to assess the risk of violence, sexual, and criminal behaviour. Systematic review and tabular meta-analysis of replication studies following PRISMA guidelines. PsycINFO, Embase, Medline, and United States Criminal Justice Reference Service Abstracts. We included replication studies from 1 January 1995 to 1 January 2011 if they provided contingency data for the offending outcome that the tools were designed to predict. We calculated the diagnostic odds ratio, sensitivity, specificity, area under the curve, positive predictive value, negative predictive value, the number needed to detain to prevent one offence, as well as a novel performance indicator-the number safely discharged. We investigated potential sources of heterogeneity using metaregression and subgroup analyses. Risk assessments were conducted on 73 samples comprising 24,847 participants from 13 countries, of whom 5879 (23.7%) offended over an average of 49.6 months. When used to predict violent offending, risk assessment tools produced low to moderate positive predictive values (median 41%, interquartile range 27-60%) and higher negative predictive values (91%, 81-95%), and a corresponding median number needed to detain of 2 (2-4) and number safely discharged of 10 (4-18). Instruments designed to predict violent offending performed better than those aimed at predicting sexual or general crime. Although risk assessment tools are widely used in clinical and criminal justice settings, their predictive accuracy varies depending on how they are used. They seem to identify low risk individuals with high levels of accuracy, but their use as sole determinants of detention, sentencing, and release is not supported by the current evidence. Further research is needed to examine their contribution to treatment and management.
Utility of a routine urinalysis in children who require clean intermittent catheterization.
Forster, C S; Haslam, D B; Jackson, E; Goldstein, S L
2017-10-01
Children who require clean intermittent catheterization (CIC) frequently have positive urine cultures. However, diagnosing a urinary tract infection (UTI) can be difficult, as there are no standardized criteria. Routine urinalysis (UA) has good predictive accuracy for UTI in the general pediatric population, but data are limited on the utility of routine UA in the population of children who require CIC. To determine the utility of UA parameters (e.g. leukocyte esterase, nitrites, and pyuria) to predict UTI in children who require CIC, and identify a composite UA that has maximal predictive accuracy for UTI. A cross-sectional study of 133 children who required CIC, and had a UA and urine culture sent as part of standard of care. Patients in the no-UTI group all had UA and urine cultures sent as part of routine urodynamics, and were asymptomatic. Patients included in the UTI group had growth of ≥50,000 colony-forming units/ml of a known uropathogen on urine culture, in addition to two or more of the following symptoms: fever, abdominal pain, back pain, foul-smelling urine, new or worse incontinence, and pain with catheterization. Categorical data were compared using Chi-squared test, and continuous data were compared with Student's t-test. Sensitivity, specificity, and positive and negative predictive values were calculated for individual UA parameters, as well as the composite UA. Logistic regression was performed on potential composite UA models to identify the model that best fit the data. There was a higher proportion of patients in the no-UTI group with negative leukocyte esterase compared with the UTI group. There was a higher proportion of patients with UTI who had large leukocyte esterase and positive nitrites compared with the no-UTI group (Summary Figure). There was no between-group difference in urinary white blood cells. Positive nitrites were the most specific (84.4%) for UTI. None of the parameters had a high positive predictive value, while all had high negative predictive values. The composite model with the best Akaike information criterion was >10 urinary white blood cells and either moderate or large leukocyte esterase, which had a positive predictive value of 33.3 and a negative predictive value of 90.4. Routine UA had limited sensitivity, but moderate specificity, in predicting UTI in children who required CIC. The composite UA and moderate or large leukocyte esterase both had good negative predictive values for the outcome of UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Inage, Terunaga; Nakajima, Takahiro; Itoga, Sakae; Ishige, Takayuki; Fujiwara, Taiki; Sakairi, Yuichi; Wada, Hironobu; Suzuki, Hidemi; Iwata, Takekazu; Chiyo, Masako; Yoshida, Shigetoshi; Matsushita, Kazuyuki; Yasufuku, Kazuhiro; Yoshino, Ichiro
2018-06-13
The limited negative predictive value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has often been discussed. The aim of this study was to identify a highly sensitive molecular biomarker for lymph node staging by EBUS-TBNA. Five microRNAs (miRNAs) (miR-200a, miR-200b, miR-200c, miR-141, and let-7e) were selected as biomarker candidates for the detection of nodal metastasis in a miRNA expression analysis. After having established a cutoff level of expression for each marker to differentiate malignant from benign lymph nodes among surgically dissected lymph nodes, the cutoff level was applied to snap-frozen EBUS-TBNA samples. Archived formalin-fixed paraffin- embedded (FFPE) samples rebiopsied by EBUS-TBNA after induction chemoradiotherapy were also analyzed. The expression of all candidate miRNAs was significantly higher in metastatic lymph nodes than in benign ones (p < 0.05) among the surgical samples. miR-200c showed the highest diagnostic yield, with a sensitivity of 95.4% and a specificity of 100%. When the cutoff value for miR-200c was applied to the snap-frozen EBUS-TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.4, 81.8, 95.0, 90.0, and 94.0%, respectively. For restaging FFPE EBUS- TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 60.0, 80.0, 100, and 84.6%, respectively. Among the restaged samples, 4 malignant lymph nodes were false negative by EBUS-TBNA, but they were accurately identified by miR-200c. miR-200c can be used as a highly sensitive molecular staging biomarker that will enhance nodal staging of lung cancer. © 2018 S. Karger AG, Basel.
Chen, Zhiru; Hong, Wenxue
2016-02-01
Considering the low accuracy of prediction in the positive samples and poor overall classification effects caused by unbalanced sample data of MicroRNA (miRNA) target, we proposes a support vector machine (SVM)-integration of under-sampling and weight (IUSM) algorithm in this paper, an under-sampling based on the ensemble learning algorithm. The algorithm adopts SVM as learning algorithm and AdaBoost as integration framework, and embeds clustering-based under-sampling into the iterative process, aiming at reducing the degree of unbalanced distribution of positive and negative samples. Meanwhile, in the process of adaptive weight adjustment of the samples, the SVM-IUSM algorithm eliminates the abnormal ones in negative samples with robust sample weights smoothing mechanism so as to avoid over-learning. Finally, the prediction of miRNA target integrated classifier is achieved with the combination of multiple weak classifiers through the voting mechanism. The experiment revealed that the SVM-IUSW, compared with other algorithms on unbalanced dataset collection, could not only improve the accuracy of positive targets and the overall effect of classification, but also enhance the generalization ability of miRNA target classifier.
Castagneto, B; Di Pietrantonj, C; Stevani, I; Anfossi, A; Arzese, M; Giorcelli, L; Giaretto, L
2013-12-01
The importance of prognostic value of the comprehensive geriatric assessment (CGA) is well known in geriatric oncology, but there is no consensus on the use of alternative abbreviated screening methods for the evaluation of older patient disabilities. The participants in this study underwent vulnerable elderly survey 13 (VES 13) at first entry in Oncology Department and were later assessed by a geriatrician according to CGA. A score >3 for VES 13 identified patients as vulnerable. Aim of this study was to evaluate the specificity, sensibility, positive predictive value (PPV), and negative predictive value (NPV) of VES 13 versus cumulative illness rating scale (CIRS), activities of daily living (ADL), instrumental activities of daily living (IADL), and short portable mental status questionnaire (SPMSQ). Hundred and seventeen patients (mean age 78.8 years) entered the study. The NPV of VES was 74.6% for CIRS, 90.1% for IADL, 93.0% for ADL, and 100% for SPMSQ. As for PPV, the VES 13 showed no accuracy. We can conclude that VES 13 demonstrated sufficient accuracy as a screening test in identifying elderly "fit" patients in order to spare the more time-consuming CGA.
Siddiqui, Ali A; Fein, Michael; Kowalski, Thomas E; Loren, David E; Eloubeidi, Mohamad A
2012-09-01
Prior studies have reported that the presence of prior biliary stent may interfere with EUS visualization of pancreatic tumors. We aimed to compare the influence of the biliary plastic and fully covered self-expanding metal stents (CSEMS) on the accuracy of EUS-FNA cytology in patients with solid pancreatic masses. We conducted a retrospective study evaluating 677 patients with solid pancreatic head/uncinate lesions and a previous biliary stent in whom EUS-FNA was performed. The patients were stratified into two groups: (1) those with a plastic stents and (2) those with CSEMS. Performance characteristics of EUS-FNA including the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were compared between the two groups. The frequency of obtaining an adequate cytology by EUS-FNA was similar in both the CSEMS group and the plastic stent group (97 vs. 97.1 % respectively; p = 1.0). The sensitivity, specificity, and accuracy of EUS-FNA was not significantly different between patients with CSEMS and plastic stents (96.8, 100, 100 % and 97.3, 98, 99.8 %, respectively). The negative predictive value for EUS-FNA was lower in the CSEMS group compared to the plastic stent group (66.6 vs. 78.1 % respectively; p = 0.42). There was one false-positive cytology in the plastic stent group compared to none in the CSEMS group. In a retrospective cohort trial, EUS-FNA was found to be highly accurate and safe in diagnosing patients with suspected pancreatic cancer, even in the presence of a plastic or metallic biliary stent. The presence of a stent did not contribute to a higher false-positive cytology rate.
Genomic-Enabled Prediction Kernel Models with Random Intercepts for Multi-environment Trials.
Cuevas, Jaime; Granato, Italo; Fritsche-Neto, Roberto; Montesinos-Lopez, Osval A; Burgueño, Juan; Bandeira E Sousa, Massaine; Crossa, José
2018-03-28
In this study, we compared the prediction accuracy of the main genotypic effect model (MM) without G×E interactions, the multi-environment single variance G×E deviation model (MDs), and the multi-environment environment-specific variance G×E deviation model (MDe) where the random genetic effects of the lines are modeled with the markers (or pedigree). With the objective of further modeling the genetic residual of the lines, we incorporated the random intercepts of the lines ([Formula: see text]) and generated another three models. Each of these 6 models were fitted with a linear kernel method (Genomic Best Linear Unbiased Predictor, GB) and a Gaussian Kernel (GK) method. We compared these 12 model-method combinations with another two multi-environment G×E interactions models with unstructured variance-covariances (MUC) using GB and GK kernels (4 model-method). Thus, we compared the genomic-enabled prediction accuracy of a total of 16 model-method combinations on two maize data sets with positive phenotypic correlations among environments, and on two wheat data sets with complex G×E that includes some negative and close to zero phenotypic correlations among environments. The two models (MDs and MDE with the random intercept of the lines and the GK method) were computationally efficient and gave high prediction accuracy in the two maize data sets. Regarding the more complex G×E wheat data sets, the prediction accuracy of the model-method combination with G×E, MDs and MDe, including the random intercepts of the lines with GK method had important savings in computing time as compared with the G×E interaction multi-environment models with unstructured variance-covariances but with lower genomic prediction accuracy. Copyright © 2018 Cuevas et al.
Genomic-Enabled Prediction Kernel Models with Random Intercepts for Multi-environment Trials
Cuevas, Jaime; Granato, Italo; Fritsche-Neto, Roberto; Montesinos-Lopez, Osval A.; Burgueño, Juan; Bandeira e Sousa, Massaine; Crossa, José
2018-01-01
In this study, we compared the prediction accuracy of the main genotypic effect model (MM) without G×E interactions, the multi-environment single variance G×E deviation model (MDs), and the multi-environment environment-specific variance G×E deviation model (MDe) where the random genetic effects of the lines are modeled with the markers (or pedigree). With the objective of further modeling the genetic residual of the lines, we incorporated the random intercepts of the lines (l) and generated another three models. Each of these 6 models were fitted with a linear kernel method (Genomic Best Linear Unbiased Predictor, GB) and a Gaussian Kernel (GK) method. We compared these 12 model-method combinations with another two multi-environment G×E interactions models with unstructured variance-covariances (MUC) using GB and GK kernels (4 model-method). Thus, we compared the genomic-enabled prediction accuracy of a total of 16 model-method combinations on two maize data sets with positive phenotypic correlations among environments, and on two wheat data sets with complex G×E that includes some negative and close to zero phenotypic correlations among environments. The two models (MDs and MDE with the random intercept of the lines and the GK method) were computationally efficient and gave high prediction accuracy in the two maize data sets. Regarding the more complex G×E wheat data sets, the prediction accuracy of the model-method combination with G×E, MDs and MDe, including the random intercepts of the lines with GK method had important savings in computing time as compared with the G×E interaction multi-environment models with unstructured variance-covariances but with lower genomic prediction accuracy. PMID:29476023
The Stroke Assessment of Fall Risk (SAFR): predictive validity in inpatient stroke rehabilitation.
Breisinger, Terry P; Skidmore, Elizabeth R; Niyonkuru, Christian; Terhorst, Lauren; Campbell, Grace B
2014-12-01
To evaluate relative accuracy of a newly developed Stroke Assessment of Fall Risk (SAFR) for classifying fallers and non-fallers, compared with a health system fall risk screening tool, the Fall Harm Risk Screen. Prospective quality improvement study conducted at an inpatient stroke rehabilitation unit at a large urban university hospital. Patients admitted for inpatient stroke rehabilitation (N = 419) with imaging or clinical evidence of ischemic or hemorrhagic stroke, between 1 August 2009 and 31 July 2010. Not applicable. Sensitivity, specificity, and area under the curve for Receiver Operating Characteristic Curves of both scales' classifications, based on fall risk score completed upon admission to inpatient stroke rehabilitation. A total of 68 (16%) participants fell at least once. The SAFR was significantly more accurate than the Fall Harm Risk Screen (p < 0.001), with area under the curve of 0.73, positive predictive value of 0.29, and negative predictive value of 0.94. For the Fall Harm Risk Screen, area under the curve was 0.56, positive predictive value was 0.19, and negative predictive value was 0.86. Sensitivity and specificity of the SAFR (0.78 and 0.63, respectively) was higher than the Fall Harm Risk Screen (0.57 and 0.48, respectively). An evidence-derived, population-specific fall risk assessment may more accurately predict fallers than a general fall risk screen for stroke rehabilitation patients. While the SAFR improves upon the accuracy of a general assessment tool, additional refinement may be warranted. © The Author(s) 2014.
Sirc-cvs cytotoxicity test: an alternative for predicting rodent acute systemic toxicity.
Kitagaki, Masato; Wakuri, Shinobu; Hirota, Morihiko; Tanaka, Noriho; Itagaki, Hiroshi
2006-10-01
An in vitro crystal violet staining method using the rabbit cornea-derived cell line (SIRC-CVS) has been developed as an alternative to predict acute systemic toxicity in rodents. Seventy-nine chemicals, the in vitro cytotoxicity of which was already reported by the Multicenter Evaluation of In vitro Toxicity (MEIC) and ICCVAM/ECVAM, were selected as test compounds. The cells were incubated with the chemicals for 72 hrs and the IC(50) and IC(35) values (microg/mL) were obtained. The results were compared to the in vivo (rat or mouse) "most toxic" oral, intraperitoneal, subcutaneous and intravenous LD(50) values (mg/kg) taken from the RTECS database for each of the chemicals by using Pearson's correlation statistics. The following parameters were calculated: accuracy, sensitivity, specificity, prevalence, positive predictability, and negative predictability. Good linear correlations (Pearson's coefficient; r>0.6) were observed between either the IC(50) or the IC(35) values and all the LD(50) values. Among them, a statistically significant high correlation (r=0.8102, p<0.001) required for acute systemic toxicity prediction was obtained between the IC(50) values and the oral LD(50) values. By using the cut-off concentrations of 2,000 mg/kg (LD(50)) and 4,225 microg/mL (IC(50)), no false negatives were observed, and the accuracy was 84.8%. From this, it is concluded that this method could be used to predict the acute systemic toxicity potential of chemicals in rodents.
Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.
Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel
2017-01-01
The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.
Predicting Negative Emotions Based on Mobile Phone Usage Patterns: An Exploratory Study
Yang, Pei-Ching; Chang, Chia-Chi; Chiang, Jung-Hsien; Chen, Ying-Yeh
2016-01-01
Background Prompt recognition and intervention of negative emotions is crucial for patients with depression. Mobile phones and mobile apps are suitable technologies that can be used to recognize negative emotions and intervene if necessary. Objective Mobile phone usage patterns can be associated with concurrent emotional states. The objective of this study is to adapt machine-learning methods to analyze such patterns for the prediction of negative emotion. Methods We developed an Android-based app to capture emotional states and mobile phone usage patterns, which included call logs (and use of apps). Visual analog scales (VASs) were used to report negative emotions in dimensions of depression, anxiety, and stress. In the system-training phase, participants were requested to tag their emotions for 14 consecutive days. Five feature-selection methods were used to determine individual usage patterns and four machine-learning methods were tested. Finally, rank product scoring was used to select the best combination to construct the prediction model. In the system evaluation phase, participants were then requested to verify the predicted negative emotions for at least 5 days. Results Out of 40 enrolled healthy participants, we analyzed data from 28 participants, including 30% (9/28) women with a mean (SD) age of 29.2 (5.1) years with sufficient emotion tags. The combination of time slots of 2 hours, greedy forward selection, and Naïve Bayes method was chosen for the prediction model. We further validated the personalized models in 18 participants who performed at least 5 days of model evaluation. Overall, the predictive accuracy for negative emotions was 86.17%. Conclusion We developed a system capable of predicting negative emotions based on mobile phone usage patterns. This system has potential for ecological momentary intervention (EMI) for depressive disorders by automatically recognizing negative emotions and providing people with preventive treatments before it escalates to clinical depression. PMID:27511748
Emotion blocks the path to learning under stereotype threat
Good, Catherine; Whiteman, Ronald C.; Maniscalco, Brian; Dweck, Carol S.
2012-01-01
Gender-based stereotypes undermine females’ performance on challenging math tests, but how do they influence their ability to learn from the errors they make? Females under stereotype threat or non-threat were presented with accuracy feedback after each problem on a GRE-like math test, followed by an optional interactive tutorial that provided step-wise problem-solving instruction. Event-related potentials tracked the initial detection of the negative feedback following errors [feedback related negativity (FRN), P3a], as well as any subsequent sustained attention/arousal to that information [late positive potential (LPP)]. Learning was defined as success in applying tutorial information to correction of initial test errors on a surprise retest 24-h later. Under non-threat conditions, emotional responses to negative feedback did not curtail exploration of the tutor, and the amount of tutor exploration predicted learning success. In the stereotype threat condition, however, greater initial salience of the failure (FRN) predicted less exploration of the tutor, and sustained attention to the negative feedback (LPP) predicted poor learning from what was explored. Thus, under stereotype threat, emotional responses to negative feedback predicted both disengagement from learning and interference with learning attempts. We discuss the importance of emotion regulation in successful rebound from failure for stigmatized groups in stereotype-salient environments. PMID:21252312
Emotion blocks the path to learning under stereotype threat.
Mangels, Jennifer A; Good, Catherine; Whiteman, Ronald C; Maniscalco, Brian; Dweck, Carol S
2012-02-01
Gender-based stereotypes undermine females' performance on challenging math tests, but how do they influence their ability to learn from the errors they make? Females under stereotype threat or non-threat were presented with accuracy feedback after each problem on a GRE-like math test, followed by an optional interactive tutorial that provided step-wise problem-solving instruction. Event-related potentials tracked the initial detection of the negative feedback following errors [feedback related negativity (FRN), P3a], as well as any subsequent sustained attention/arousal to that information [late positive potential (LPP)]. Learning was defined as success in applying tutorial information to correction of initial test errors on a surprise retest 24-h later. Under non-threat conditions, emotional responses to negative feedback did not curtail exploration of the tutor, and the amount of tutor exploration predicted learning success. In the stereotype threat condition, however, greater initial salience of the failure (FRN) predicted less exploration of the tutor, and sustained attention to the negative feedback (LPP) predicted poor learning from what was explored. Thus, under stereotype threat, emotional responses to negative feedback predicted both disengagement from learning and interference with learning attempts. We discuss the importance of emotion regulation in successful rebound from failure for stigmatized groups in stereotype-salient environments.
Ebrahimabadi, Sahar; Moghadam, Ahmad Bagheri; Vakili, Mohammadali; Modanloo, Mahnaz; Khoddam, Homeira
2017-08-01
The use of weaning predictive indicators can avoid early extubation and wrongful prolonged mechanical ventilation. This study aimed to determine the power of the integrative weaning index (IWI) in predicting the success rate of the spontaneous breathing trial (SBT) in patients under mechanical ventilation. In this prospective study, 105 patients undergoing mechanical ventilation for over 48 h were enrolled. Before weaning initiation, the IWI was calculated and based on the defined cutoff point (≥25), the success rate of the SBT was predicted. In case of weaning from the device, 2-h SBT was performed and the physiologic and respiratory indices were continuously studied while being intubated. If they were in the normal range besides the patient's tolerance, the test was considered as a success. The result was then compared with the IWI and further analyzed. The SBT was successful in 90 (85.7%) and unsuccessful in 15 (14.3%) cases. The difference between the true patient outcome after SBT, and the IWI prediction was 0.143 according to the Kappa agreement coefficient ( P < 0.001). Moreover, regarding the predictive power, IWI had high sensitivity (95.6%), specificity (40%), positive and negative predictive values (90.5% and 60), positive and negative likelihood ratios (1.59 and 0.11), and accuracy (86.7%). The IWI as a more objective indicator has acceptable accuracy and power for predicting the 2-h SBT result. Therefore, in addition to the reliable prediction of the final weaning outcome, it has favorable power to predict if the patient is ready to breathe spontaneously as the first step to weaning.
Ebrahimabadi, Sahar; Moghadam, Ahmad Bagheri; Vakili, Mohammadali; Modanloo, Mahnaz; Khoddam, Homeira
2017-01-01
Background and Aims: The use of weaning predictive indicators can avoid early extubation and wrongful prolonged mechanical ventilation. This study aimed to determine the power of the integrative weaning index (IWI) in predicting the success rate of the spontaneous breathing trial (SBT) in patients under mechanical ventilation. Materials and Methods: In this prospective study, 105 patients undergoing mechanical ventilation for over 48 h were enrolled. Before weaning initiation, the IWI was calculated and based on the defined cutoff point (≥25), the success rate of the SBT was predicted. In case of weaning from the device, 2-h SBT was performed and the physiologic and respiratory indices were continuously studied while being intubated. If they were in the normal range besides the patient's tolerance, the test was considered as a success. The result was then compared with the IWI and further analyzed. Results: The SBT was successful in 90 (85.7%) and unsuccessful in 15 (14.3%) cases. The difference between the true patient outcome after SBT, and the IWI prediction was 0.143 according to the Kappa agreement coefficient (P < 0.001). Moreover, regarding the predictive power, IWI had high sensitivity (95.6%), specificity (40%), positive and negative predictive values (90.5% and 60), positive and negative likelihood ratios (1.59 and 0.11), and accuracy (86.7%). Conclusion: The IWI as a more objective indicator has acceptable accuracy and power for predicting the 2-h SBT result. Therefore, in addition to the reliable prediction of the final weaning outcome, it has favorable power to predict if the patient is ready to breathe spontaneously as the first step to weaning. PMID:28904477
Ahmed, Ayesha; Ahmed, Sajjad
2004-01-01
The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.
Wong, Grace Lai-Hung; Kwok, Raymond; Chan, Henry Lik-Yuen; Tang, Stephen Pui-Kit; Lee, Eugenia; Lam, Thomas Chi-Ho; Lau, Tiffany Wing-Yan; Ma, Teresa Man-Kee; Wong, Betsy Chi-Kuen; Wong, Vincent Wai-Sun
2016-08-01
we aimed to investigate the accuracy of liver (LSM) spleen stiffness measurement (SSM) with transient elastography (TE) to predict varices in the presence of non-selective beta-blockers (NSBB). In this cross-sectional study of consecutive patients with chronic hepatitis B (CHB) and cirrhosis, all patients underwent TE and upper endoscopic examinations. LSM and SSM in predicting varices in patients receiving and not receiving NSBB were evaluated. Altogether 144 CHB patients (29 receiving NSBB; 35 with any varices, 31 and 11 with esophageal and gastric varices, respectively) were recruited. Their mean LSM and SSM were 13.3 ± 9.0 kPa and 32.8 ± 19.2 kPa, respectively. The correlation between LSM and SSM was better in the NSBB subgroup (r = 0.525, P = 0.003) than its counterpart (r = 0.329, P < 0.001). The area under receiver operating characteristic curve (AUROC) of LSM and SSM for any varices was 0.675 and 0.685 (P = 0.002 and 0.001), respectively. SSM of 18.9 kPa had a negative predictive value of 92.1% and negative likelihood ratio of 0.27 for ruling out any varices; and SSM of 54.9 kPa had a positive predictive value of 56.5% and a positive likelihood ratio of 4.05 to rule in varices. The AUROC of LSM for varices was 0.742 and 0.549 in patients with or without NSBB, respectively; the corresponding AUROC of SSM was 0.572 and 0.603, respectively. SSM only has modest accuracy to predict varices independent of NSBB use. An SSM cutoff value of 18.9 kPa may be adopted to achieve a high negative predictive value to rule out varices. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
Paz-Alonso, Pedro M; Goodman, Gail S
2016-01-01
In the present study, we investigated age differences in children's eyewitness memory and suggestibility for negative and positive events that children often experience during middle childhood. We first examined 216 ratings by children aged 8-12 years of the frequency and intensity of personal negative and positive experiences (Study 1). Based on those ratings, videotapes depicting the most frequent and intense negative (an accident) and positive (a family excursion) events were developed. A new sample of 227 children aged 8-12 years was tested for recognition memory of the videotapes using the three-stage post-event misinformation procedure (Study 2). Compared with 8- to 9-year-olds, 10- to 12-year-olds exhibited less memory malleability and less compliance with false information. Age improvements in recognition accuracy were also evident for children who watched the negative event, but not for those who watched the positive event. Compliance predicted misinformation effects, particularly in regard to peripheral details. Thus, using ecologically representative emotional events, age differences in suggestibility and memory accuracy emerged, especially for negative events.Theoretical and forensic implications concerning children's eyewitness memory and suggestibility are discussed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Accuracy of ultrasound in prediction of rectosigmoid infiltration in epithelial ovarian cancer.
Zikan, M; Fischerova, D; Semeradova, I; Slama, J; Dundr, P; Weinberger, V; Dusek, L; Cibula, D
2017-10-01
To examine prospectively the accuracy of ultrasound in predicting rectosigmoid tumor infiltration in patients with epithelial ovarian cancer. Patients referred for a suspicious pelvic mass between 2012 and 2014 were examined by ultrasound following the standard protocol for assessment of tumor infiltration. Of the 245 patients examined, 191 had proven ovarian cancer and underwent primary surgery and were included in the analysis. Patients with apparently benign or inoperable disease were excluded. Rectosigmoid infiltration was evaluated by histopathology or according to perioperative findings. Clinical, pathological and laboratory parameters were analyzed as factors potentially affecting the sensitivity and specificity of sonography. The sensitivity of ultrasound in detecting rectosigmoid infiltration in patients with ovarian cancer was 86.3%, with specificity of 95.8%, positive predictive value of 92.6%, negative predictive value of 91.9% and overall accuracy of 92.1%. Ultrasound is a highly accurate method for detecting rectosigmoid tumor infiltration in ovarian cancer patients, and thus, can be used for planning adequate management, including patient consultation, surgical team planning, suitable operating time and postoperative care. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Dai, Cong; Jiang, Min; Sun, Ming-Jun; Cao, Qin
2018-05-01
Fecal immunochemical test (FIT) is a promising marker for assessment of inflammatory bowel disease activity. However, the utility of FIT for predicting mucosal healing (MH) of ulcerative colitis (UC) patients has yet to be clearly demonstrated. The objective of our study was to perform a diagnostic test accuracy test meta-analysis evaluating the diagnostic accuracy of FIT in predicting MH of UC patients. We systematically searched the databases from inception to November 2017 that evaluated MH in UC. The methodological quality of each study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies checklist. The extracted data were pooled using a summary receiver operating characteristic curve model. Random-effects model was used to summarize the diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Six studies comprising 625 UC patients were included in the meta-analysis. The pooled sensitivity and specificity values for predicting MH in UC were 0.77 (95% confidence interval [CI], 0.72-0.81) and 0.81 (95% CI, 0.76-0.85), respectively. The FIT level had a high rule-in value (positive likelihood ratio, 3.79; 95% CI, 2.85-5.03) and a moderate rule-out value (negative likelihood ratio, 0.26; 95% CI, 0.16-0.43) for predicting MH in UC. The results of the receiver operating characteristic curve analysis (area under the curve, 0.88; standard error of the mean, 0.02) and diagnostic odds ratio (18.08; 95% CI, 9.57-34.13) also revealed improved discrimination for identifying MH in UC with FIT concentration. Our meta-analysis has found that FIT is a simple, reliable non-invasive marker for predicting MH in UC patients. © 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Takenouchi, Osamu; Miyazawa, Masaaki; Saito, Kazutoshi; Ashikaga, Takao; Sakaguchi, Hitoshi
2013-01-01
To meet the urgent need for a reliable alternative test for predicting skin sensitizing potential of many chemicals, we have developed a cell-based in vitro test, human Cell Line Activation Test (h-CLAT). However, the predictive performance for lipophilic chemicals in the h-CLAT still remains relatively unknown. Moreover, it's suggested that low water solubility of chemicals might induce false negative outcomes. Thus, in this study, we tested relatively low water soluble 37 chemicals with log Kow values above and below 3.5 in the h-CLAT. The small-scale assessment resulted in nine false negative outcomes for chemicals with log Kow values greater than 3.5. We then created a dataset of 143 chemicals by combining the existing dataset of 106 chemicals and examined the predictive performance of the h-CLAT for chemicals with a log Kow of less than 3.5; a total of 112 chemicals from the 143 chemicals in the dataset. The sensitivity and overall accuracy for the 143 chemicals were 83% and 80%, respectively. In contrast, sensitivity and overall accuracy for the 112 chemicals with log Kow values below 3.5 improved to 94% and 88%, respectively. These data suggested that the h-CLAT could successfully detect sensitizers with log Kow values up to 3.5. When chemicals with log Kow values greater than 3.5 that were deemed positive by h-CLAT were included with the 112 chemicals, the sensitivity and accuracy in terms of the resulting applicable 128 chemicals out of the 143 chemicals became 95% and 88%, respectively. The use of log Kow values gave the h-CLAT a higher predictive performance. Our results demonstrated that the h-CLAT could predict sensitizing potential of various chemicals, which contain lipophilic chemicals using a large-scale chemical dataset.
Purdom, Catherine L; Kirlin, Kristin A; Hoerth, Matthew T; Noe, Katherine H; Drazkowski, Joseph F; Sirven, Joseph I; Locke, Dona E C
2012-12-01
The Somatic Complaints scale (SOM) and Conversion subscale (SOM-C) of the Personality Assessment Inventory perform best in classifying psychogenic non-epileptic seizures (PNES) from epileptic seizures (ES); however, the impact of positive impression management (PIM) and negative impression management (NIM) scales on SOM and SOM-C classification has not been examined. We studied 187 patients from an epilepsy monitoring unit with confirmed PNES or ES. On SOM, the best cut score was 72.5 T when PIM was elevated and 69.5 T when there was no bias. On SOM-C, when PIM was elevated, the best cut score was 67.5 T and 76.5 T when there was no bias. Negative impression management elevations (n=9) were too infrequent to analyze separately. Despite similarities in classification accuracy, there were differences in sensitivity and specificity with and without PIM, impacting positive and negative predictive values. The presence of PIM bias generally increases positive predictive power of SOM and SOM-C but decreases negative predictive power. Copyright © 2012 Elsevier Inc. All rights reserved.
Xie, Jianwen; Douglas, Pamela K; Wu, Ying Nian; Brody, Arthur L; Anderson, Ariana E
2017-04-15
Brain networks in fMRI are typically identified using spatial independent component analysis (ICA), yet other mathematical constraints provide alternate biologically-plausible frameworks for generating brain networks. Non-negative matrix factorization (NMF) would suppress negative BOLD signal by enforcing positivity. Spatial sparse coding algorithms (L1 Regularized Learning and K-SVD) would impose local specialization and a discouragement of multitasking, where the total observed activity in a single voxel originates from a restricted number of possible brain networks. The assumptions of independence, positivity, and sparsity to encode task-related brain networks are compared; the resulting brain networks within scan for different constraints are used as basis functions to encode observed functional activity. These encodings are then decoded using machine learning, by using the time series weights to predict within scan whether a subject is viewing a video, listening to an audio cue, or at rest, in 304 fMRI scans from 51 subjects. The sparse coding algorithm of L1 Regularized Learning outperformed 4 variations of ICA (p<0.001) for predicting the task being performed within each scan using artifact-cleaned components. The NMF algorithms, which suppressed negative BOLD signal, had the poorest accuracy compared to the ICA and sparse coding algorithms. Holding constant the effect of the extraction algorithm, encodings using sparser spatial networks (containing more zero-valued voxels) had higher classification accuracy (p<0.001). Lower classification accuracy occurred when the extracted spatial maps contained more CSF regions (p<0.001). The success of sparse coding algorithms suggests that algorithms which enforce sparsity, discourage multitasking, and promote local specialization may capture better the underlying source processes than those which allow inexhaustible local processes such as ICA. Negative BOLD signal may capture task-related activations. Copyright © 2017 Elsevier B.V. All rights reserved.
Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen
2006-01-01
OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726
Porto, William F; Pires, Állan S; Franco, Octavio L
2017-08-07
The antimicrobial activity prediction tools aim to help the novel antimicrobial peptides (AMP) sequences discovery, utilizing machine learning methods. Such approaches have gained increasing importance in the generation of novel synthetic peptides by means of rational design techniques. This study focused on predictive ability of such approaches to determine the antimicrobial sequence activities, which were previously characterized at the protein level by in vitro studies. Using four web servers and one standalone software, we evaluated 78 sequences generated by the so-called linguistic model, being 40 designed and 38 shuffled sequences, with ∼60 and ∼25% of identity to AMPs, respectively. The ab initio molecular modelling of such sequences indicated that the structure does not affect the predictions, as both sets present similar structures. Overall, the systems failed on predicting shuffled versions of designed peptides, as they are identical in AMPs composition, which implies in accuracies below 30%. The prediction accuracy is negatively affected by the low specificity of all systems here evaluated, as they, on the other hand, reached 100% of sensitivity. Our results suggest that complementary approaches with high specificity, not necessarily high accuracy, should be developed to be used together with the current systems, overcoming their limitations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Efficiency of the Bethesda System for Thyroid Cytopathology.
Mora-Guzmán, Ismael; Muñoz de Nova, José Luis; Marín-Campos, Cristina; Jiménez-Heffernan, José Antonio; Cuesta Pérez, Juan Julián; Lahera Vargas, Marcos; Torres Mínguez, Emma; Martín-Pérez, Elena
2018-03-28
Fine-needle aspiration biopsies are a key tool for preoperative assessment of thyroid nodules, and the Bethesda system is the preferred method to report cytological analysis. The purpose of this study is to assess the efficiency of the Bethesda system to identify the malignancy risk of thyroid nodules. Patients who underwent thyroid surgery between June 2010 and June 2017 were included. Samples were classified into 6categories according to rates of malignancy associated with each diagnostic category. In order to investigate the correlation between categories, a statistical analysis compared the categories with pathology reports. Diagnostic indicators were calculated as a screening test (categories IV, V, VI as true-positive) and as a method to identify malignancy (V, VI as true-positive). In a series of 522 patients, we found 184 (35.2%) malignant tumours, papillary carcinoma being the most prevalent with 155 cases (84.2%). Malignant rates for diagnostic categories were: I, 0%; II, 1.5%; III, 6.4%; IV, 31%; V, 86.5%; VI, 100%. A robust correlation was identified between categories on statistical analysis. For the «screening test» analysis, sensitivity was 98.9%, specificity 84.4%, positive predictive value 69.6%, negative predictive value 99.5%, and diagnostic accuracy 88.2%. Analysing the accuracy to detect malignancy, values were: sensitivity 98.6%, specificity 97.6%, positive predictive value 93.5%, negative predictive value 99.5%, diagnostic accuracy 97.9%. The Bethesda system is a clear and reliable approach to report thyroid cytology and therefore is an effective tool to identify malignancy risk and guide clinical management. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Nelson, Joan M; Cook, Paul F; Ingram, Jennifer C
2014-02-01
To evaluate constructs from the theory of planned behavior (TPB, Ajzen 2002) - attitudes, sense of control, subjective norms and intentions - as predictors of accuracy in blood pressure monitoring. Despite numerous initiatives aimed at teaching blood pressure measurement techniques, many healthcare providers measure blood pressures incorrectly. Descriptive, cohort design. Medical assistants and licensed practical nurses were asked to complete a questionnaire on TPB variables. These nursing staff's patients had their blood pressures measured and completed a survey about techniques used to measure their blood pressure. We correlated nursing staff's responses on the TBP questionnaire with their intention to measure an accurate blood pressure and with the difference between their actual blood pressure measurement and a second measurement taken by a researcher immediately after the clinic visit. Patients' perceptions of MAs' and LPNs' blood pressure measurement techniques were examined descriptively. Perceived control and social norm predicted intention to measure an accurate blood pressure, with a negative relationship between knowledge and intention. Consistent with the TPB, intention was the only significant predictor of blood pressure measurement accuracy. Theory of planned behavior constructs predicted the healthcare providers' intention to measure blood pressure accurately and intention predicted the actual accuracy of systolic blood pressure measurement. However, participants' knowledge about blood pressure measurement had an unexpected negative relationship with their intentions. These findings have important implications for nursing education departments and organisations which traditionally invest significant time and effort in annual competency training focused on knowledge enhancement by staff. This study suggests that a better strategy might involve efforts to enhance providers' intention to change, particularly by changing social norms or increasing perceived control of the behaviour by nursing staff. © 2013 Blackwell Publishing Ltd.
De Geer, Jakob; Sandstedt, Mårten; Björkholm, Anders; Alfredsson, Joakim; Janzon, Magnus; Engvall, Jan; Persson, Anders
2016-10-01
The significance of a coronary stenosis can be determined by measuring the fractional flow reserve (FFR) during invasive coronary angiography. Recently, methods have been developed which claim to be able to estimate FFR using image data from standard coronary computed tomography angiography (CCTA) exams. To evaluate the accuracy of non-invasively computed fractional flow reserve (cFFR) from CCTA. A total of 23 vessels in 21 patients who had undergone both CCTA and invasive angiography with FFR measurement were evaluated using a cFFR software prototype. The cFFR results were compared to the invasively obtained FFR values. Correlation was calculated using Spearman's rank correlation, and agreement using intraclass correlation coefficient (ICC). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for significant stenosis (defined as both FFR ≤0.80 and FFR ≤0.75) were calculated. The mean cFFR value for the whole group was 0.81 and the corresponding mean invFFR value was 0.84. The cFFR sensitivity for significant stenosis (FFR ≤0.80/0.75) on a per-lesion basis was 0.83/0.80, specificity was 0.76/0.89, and accuracy 0.78/0.87. The positive predictive value was 0.56/0.67 and the negative predictive value was 0.93/0.94. The Spearman rank correlation coefficient was ρ = 0.77 (P < 0.001) and ICC = 0.73 (P < 0.001). This particular CCTA-based cFFR software prototype allows for a rapid, non-invasive on-site evaluation of cFFR. The results are encouraging and cFFR may in the future be of help in the triage to invasive coronary angiography. © The Foundation Acta Radiologica 2015.
NegGOA: negative GO annotations selection using ontology structure.
Fu, Guangyuan; Wang, Jun; Yang, Bo; Yu, Guoxian
2016-10-01
Predicting the biological functions of proteins is one of the key challenges in the post-genomic era. Computational models have demonstrated the utility of applying machine learning methods to predict protein function. Most prediction methods explicitly require a set of negative examples-proteins that are known not carrying out a particular function. However, Gene Ontology (GO) almost always only provides the knowledge that proteins carry out a particular function, and functional annotations of proteins are incomplete. GO structurally organizes more than tens of thousands GO terms and a protein is annotated with several (or dozens) of these terms. For these reasons, the negative examples of a protein can greatly help distinguishing true positive examples of the protein from such a large candidate GO space. In this paper, we present a novel approach (called NegGOA) to select negative examples. Specifically, NegGOA takes advantage of the ontology structure, available annotations and potentiality of additional annotations of a protein to choose negative examples of the protein. We compare NegGOA with other negative examples selection algorithms and find that NegGOA produces much fewer false negatives than them. We incorporate the selected negative examples into an efficient function prediction model to predict the functions of proteins in Yeast, Human, Mouse and Fly. NegGOA also demonstrates improved accuracy than these comparing algorithms across various evaluation metrics. In addition, NegGOA is less suffered from incomplete annotations of proteins than these comparing methods. The Matlab and R codes are available at https://sites.google.com/site/guoxian85/neggoa gxyu@swu.edu.cn Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Vallejo, Roger L; Leeds, Timothy D; Gao, Guangtu; Parsons, James E; Martin, Kyle E; Evenhuis, Jason P; Fragomeni, Breno O; Wiens, Gregory D; Palti, Yniv
2017-02-01
Previously, we have shown that bacterial cold water disease (BCWD) resistance in rainbow trout can be improved using traditional family-based selection, but progress has been limited to exploiting only between-family genetic variation. Genomic selection (GS) is a new alternative that enables exploitation of within-family genetic variation. We compared three GS models [single-step genomic best linear unbiased prediction (ssGBLUP), weighted ssGBLUP (wssGBLUP), and BayesB] to predict genomic-enabled breeding values (GEBV) for BCWD resistance in a commercial rainbow trout population, and compared the accuracy of GEBV to traditional estimates of breeding values (EBV) from a pedigree-based BLUP (P-BLUP) model. We also assessed the impact of sampling design on the accuracy of GEBV predictions. For these comparisons, we used BCWD survival phenotypes recorded on 7893 fish from 102 families, of which 1473 fish from 50 families had genotypes [57 K single nucleotide polymorphism (SNP) array]. Naïve siblings of the training fish (n = 930 testing fish) were genotyped to predict their GEBV and mated to produce 138 progeny testing families. In the following generation, 9968 progeny were phenotyped to empirically assess the accuracy of GEBV predictions made on their non-phenotyped parents. The accuracy of GEBV from all tested GS models were substantially higher than the P-BLUP model EBV. The highest increase in accuracy relative to the P-BLUP model was achieved with BayesB (97.2 to 108.8%), followed by wssGBLUP at iteration 2 (94.4 to 97.1%) and 3 (88.9 to 91.2%) and ssGBLUP (83.3 to 85.3%). Reducing the training sample size to n = ~1000 had no negative impact on the accuracy (0.67 to 0.72), but with n = ~500 the accuracy dropped to 0.53 to 0.61 if the training and testing fish were full-sibs, and even substantially lower, to 0.22 to 0.25, when they were not full-sibs. Using progeny performance data, we showed that the accuracy of genomic predictions is substantially higher than estimates obtained from the traditional pedigree-based BLUP model for BCWD resistance. Overall, we found that using a much smaller training sample size compared to similar studies in livestock, GS can substantially improve the selection accuracy and genetic gains for this trait in a commercial rainbow trout breeding population.
Ferro, Matteo; Bruzzese, Dario; Perdonà, Sisto; Mazzarella, Claudia; Marino, Ada; Sorrentino, Alessandra; Di Carlo, Angelina; Autorino, Riccardo; Di Lorenzo, Giuseppe; Buonerba, Carlo; Altieri, Vincenzo; Mariano, Angela; Macchia, Vincenzo; Terracciano, Daniela
2012-08-16
Indication for prostate biopsy is presently mainly based on prostate-specific antigen (PSA) serum levels and digital-rectal examination (DRE). In view of the unsatisfactory accuracy of these two diagnostic exams, research has focused on novel markers to improve pre-biopsy prostate cancer detection, such as phi and PCA3. The purpose of this prospective study was to assess the diagnostic accuracy of phi and PCA3 for prostate cancer using biopsy as gold standard. Phi index (Beckman coulter immunoassay), PCA3 score (Progensa PCA3 assay) and other established biomarkers (tPSA, fPSA and %fPSA) were assessed before a 18-core prostate biopsy in a group of 251 subjects at their first biopsy. Values of %p2PSA and phi were significantly higher in patients with PCa compared with PCa-negative group (p<0.001) and also compared with high grade prostatic intraepithelial neoplasia (HGPIN) (p<0.001). PCA3 score values were significantly higher in PCa compared with PCa-negative subjects (p<0.001) and in HGPIN vs PCa-negative patients (p<0.001). ROC curve analysis showed that %p2PSA, phi and PCA3 are predictive of malignancy. In conclusion, %p2PSA, phi and PCA3 may predict a diagnosis of PCa in men undergoing their first prostate biopsy. PCA3 score is more useful in discriminating between HGPIN and non-cancer. Copyright © 2012 Elsevier B.V. All rights reserved.
Döner, Rana Kaya; Sager, Sait; Görtan, Fatma Arzu; Topuz, Özge Vural; Akyel, Reşit; Vatankulu, Betül; Baran, Ahmet; Teksoz, Serkan; Sönmezoglu, Kerim
2016-01-01
This retrospective study aims to assess the cut-off value of thyroglobulin (Tg) levels in nux or metastatic well-differentiated thyroid cancers (DTCs) with normal anti-Tg levels using with fluorodeoxyglucose/positron emission tomography/computed tomography (FDG PET/CT). We reviewed FDG PET/CT images of 104 patients with well DTC (28 men, 76 women) whose: Iodine-131 (131 I) whole-body scanning was negative but had elevated Tg with normal anti-Tg levels. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of florine-18-FDG PET/CT findings were found to be 95.92%, 87.27%, 87.04%, 96.00%, and 91.35%, respectively. The best Tg cut-off value was found to be 10.4 ng/ml. In the Tg level <10.4 ng/ml group, the sensitivity, specificity, PPV, NPV, and accuracy of FDG PET/CT were found to be 94.1%, 91.30%, 88.8%, 95.4%, and 92.5%, respectively. In the other group, which Tg level ≥10.4 ng/ml, sensitivity, specificity, PPV, NPV, and accuracy of FDG PET/CT exams were found to be 96.8%, 84.3%, 86.1%, 96.4%, and 90.6%, respectively. FDG PET/CT imaging is a valuable imaging method in the evaluation of patients with elevated serum Tg levels and normal anti-Tg levels. Furthermore, it has potential utility in the dedifferentiation of active foci that are present, and in assessing optimal decision making during follow-up.
Maffei, E; Martini, C; Rossi, A; Mollet, N; Lario, C; Castiglione Morelli, M; Clemente, A; Gentile, G; Arcadi, T; Seitun, S; Catalano, O; Aldrovandi, A; Cademartiri, F
2012-08-01
The authors evaluated the diagnostic accuracy of second-generation dual-source (DSCT) computed tomography coronary angiography (CTCA) with iterative reconstructions for detecting obstructive coronary artery disease (CAD). Between June 2010 and February 2011, we enrolled 160 patients (85 men; mean age 61.2±11.6 years) with suspected CAD. All patients underwent CTCA and conventional coronary angiography (CCA). For the CTCA scan (Definition Flash, Siemens), we use prospective tube current modulation and 70-100 ml of iodinated contrast material (Iomeprol 400 mgI/ ml, Bracco). Data sets were reconstructed with iterative reconstruction algorithm (IRIS, Siemens). CTCA and CCA reports were used to evaluate accuracy using the threshold for significant stenosis at ≥50% and ≥70%, respectively. No patient was excluded from the analysis. Heart rate was 64.3±11.9 bpm and radiation dose was 7.2±2.1 mSv. Disease prevalence was 30% (48/160). Sensitivity, specificity and positive and negative predictive values of CTCA in detecting significant stenosis were 90.1%, 93.3%, 53.2% and 99.1% (per segment), 97.5%, 91.2%, 61.4% and 99.6% (per vessel) and 100%, 83%, 71.6% and 100% (per patient), respectively. Positive and negative likelihood ratios at the per-patient level were 5.89 and 0.0, respectively. CTCA with second-generation DSCT in the real clinical world shows a diagnostic performance comparable with previously reported validation studies. The excellent negative predictive value and likelihood ratio make CTCA a first-line noninvasive method for diagnosing obstructive CAD.
Screening of depression in cardiology: A study on 617 cardiovascular patients.
Tesio, Valentina; Marra, Sebastiano; Molinaro, Stefania; Torta, Riccardo; Gaita, Fiorenzo; Castelli, Lorys
2017-10-15
Depression screening in the cardiovascular disease (CVD) care setting is under-performed, also because the issue of the optimal screening tools cut-off is still open. We analysed which HADS (Hospital Anxiety and Depression Scale) total score cut-off value shows the best properties in two groups of 357 Acute Coronary Syndrome (ACS) and 260 Chronic Coronary Artery Disease (CAD) hospitalized patients. A Receiver Operating Characteristics (ROC) curve was plotted for both groups using the Montgomery-Asberg Depression Rating Scale (MADRS) as the criterion. Accuracy, positive (PPV) and negative (NPV) predictive values were computed for different cut-off scores. The ROC curves confirmed the excellent/very good accuracy of the HADS in both groups, with an area under the curve of 0.911 for the ACS and 0.893 for the CAD patients. The cut-off of 14 showed the best compromise between high sensitivity and good specificity in both groups, with high negative predicted values (95.5% and 92.4%, respectively). Using a cut-off value of 14, the HADS could be considered a good screening tool to identify hospitalized CAD and ACS patients requiring a more accurate depression assessment, in order to promptly plan the most appropriate treatment strategies and prevent the negative effects of depression in CVD patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Amini, Reza; Sabourin, Catherine; De Koninck, Joseph
2011-12-01
Scientific study of dreams requires the most objective methods to reliably analyze dream content. In this context, artificial intelligence should prove useful for an automatic and non subjective scoring technique. Past research has utilized word search and emotional affiliation methods, to model and automatically match human judges' scoring of dream report's negative emotional tone. The current study added word associations to improve the model's accuracy. Word associations were established using words' frequency of co-occurrence with their defining words as found in a dictionary and an encyclopedia. It was hypothesized that this addition would facilitate the machine learning model and improve its predictability beyond those of previous models. With a sample of 458 dreams, this model demonstrated an improvement in accuracy from 59% to 63% (kappa=.485) on the negative emotional tone scale, and for the first time reached an accuracy of 77% (kappa=.520) on the positive scale. Copyright © 2011 Elsevier Inc. All rights reserved.
Ali, N; Nath, N C; Parvin, R; Rahman, A; Bhuiyan, T M; Rahman, M; Mohsin M N
2014-12-01
This cross sectional study was carried out in the department of gastroenterology, BIRDEM, Dhaka from January 2010 to May 2011 to determine the role of ascitic fluid ADA and serum CA-125 in the diagnosis of clinically suspected tubercular peritonitis. Total 30 patients (age 39.69 ± 21.26, 18M/12F) with clinical suspicion of tuberculosis peritonitis were included in this study after analyzing selection criteria. Laparoscopic peritoneal biopsy with 'histopathological diagnosis' was considered gold standard against which accuracics of two biomarkers (ADA & CA-125) were compared. Cut off value of ADA and CA-125 are 24 u/l, 35 U/ml respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ADA as a diagnostic modality in tuberculos peritonitis were 87.5%, 83.33%, 95.45%, 62.5% and 86.67% respectively where as CA-125 was found to have 83.33% sensitivity, 50% specificity, 86.9% positive predictive value, 42.85% negative predictive value and 76.6% accuracy. Both biomarkers are simple, non-invasive, rapid and relatively cheap diagnostic test where as laparoscopy is an invasive procedure, costly & requires trained staff and not without risk and also not feasible in all the centre in our country. So ascitic fluid ADA and serum CA-125 are important diagnostic test for peritoneal tuberculosis.
Guntupalli, Kalpalatha K; Alapat, Philip M; Bandi, Venkata D; Kushnir, Igal
2008-12-01
Computerized lung-sound analysis is a sensitive and quantitative method to identify wheezing by its typical pattern on spectral analysis. We evaluated the accuracy of the VRI, a multi-sensor, computer-based device with an automated technique of wheeze detection. The method was validated in 100 sound files from seven subjects with asthma or chronic obstructive pulmonary disease and seven healthy subjects by comparison of auscultation findings, examination of audio files, and computer detection of wheezes. Three blinded physicians identified 40 sound files with wheezes and 60 sound files without wheezes. Sensitivity and specificity were 83% and 85%, respectively. Negative predictive value and positive predictive value were 89% and 79%, respectively. Overall inter-rater agreement was 84%. False positive cases were found to contain sounds that simulate wheezes, such as background noises with high frequencies or strong noises from the throat that could be heard and identified without a stethoscope. The present findings demonstrate that the wheeze detection algorithm has good accuracy, sensitivity, specificity, negative predictive value and positive predictive value for wheeze detection in regional analyses with a single sensor and multiple sensors. Results are similar to those reported in the literature. The device is user-friendly, requires minimal patient effort, and, distinct from other devices, it provides a dynamic image of breath sound distribution with wheeze detection output in less than 1 minute.
Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J
2014-01-01
The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (<60%) for other more specific categories. Similarly, interreader agreement (kappa value) was moderate to substantial (40-80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus and E. coli, but was lower for other categories. The Tri-Plate had a higher sensitivity, accuracy, and negative predictive value for Streptococcus spp., and higher interreader agreement for some of the more specific categories. Our conclusion was that Bi-Plate and Tri-Plate results will be most reliable when used to classify infections in broad diagnostic categories such NG, GP, or GN. The Bi-Plate and Tri-Plate will have intermediate ability to identify infections as being caused by Staphylococcus spp., Streptococcus spp., or Staph. aureus. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Predictive values of thermal and electrical dental pulp tests: a clinical study.
Villa-Chávez, Carlos E; Patiño-Marín, Nuria; Loyola-Rodríguez, Juan P; Zavala-Alonso, Norma V; Martínez-Castañón, Gabriel A; Medina-Solís, Carlo E
2013-08-01
For a diagnostic test to be useful, it is necessary to determine the probability that the test will provide the correct diagnosis. Therefore, it is necessary to calculate the predictive value of diagnostics. The aim of the present study was to identify the sensitivity, specificity, positive and negative predictive values, accuracy, and reproducibility of thermal and electrical tests of pulp sensitivity. The thermal tests studied were the 1, 1, 1, 2-tetrafluoroethane (cold) and hot gutta-percha (hot) tests. For the electrical test, the Analytic Technology Pulp Tester (Analytic Technology, Redmond, WA) was used. A total of 110 teeth were tested: 60 teeth with vital pulp and 50 teeth with necrotic pulps (disease prevalence of 45%). The ideal standard was established by direct pulp inspection. The sensitivities of the diagnostic tests were 0.88 for the cold test, 0.86 for the heat test, and 0.76 for the electrical test, and the specificity was 1.0 for all 3 tests. The negative predictive value was 0.90 for the cold test, 0.89 for the heat test, and 0.83 for the electrical test, and the positive predictive value was 1.0 for all 3 tests. The highest accuracy (0.94) and reproducibility (0.88) were observed for the cold test. The cold test was the most accurate method for diagnostic testing. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
[Prognosis of acute pancreatitis by PANC 3 score].
Fukuda, James Ken; Franzon, Orli; Resende-Filho, Fernando de Oliveira; Kruel, Nicolau Fernandes; Ferri, Thiago Alessandro
2013-06-01
Acute pancreatitis is a disease of great importance in clinical practice, defined as an inflammatory process of the pancreas that may involve local tissues or affect other organs in a systemic manner, requiring, in such cases, an intensive care. To analyze the simplified stratification system of the PANC 3 score, correlating it with the Ranson score, for the prognostic definition of cases of acute pancreatitis. Was conducted a prospective, observational study in which were evaluated 65 patients who were diagnosed with acute pancreatitis. PANC 3 showed sensitivity, 31.25%; specificity,100%; positive predictive value, 100%; negative predictive value, 81.66% and accuracy, 83.07%. The PANC 3 criteria are applicable to define the severity and the prognosis of acute pancreatitis, and are not a substitute method, but rather a method to be associated with the Ranson criteria, mainly due to its high accuracy, positive predictive value and specificity.
Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L
2017-02-01
To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.
WASP (Write a Scientific Paper) using Excel - 11: Test characteristics.
Grech, Victor
2018-07-01
The calculation of various test characteristics may be required as part of a data analysis exercise. This paper explains how to set up these calculations in Microsoft Excel in order to obtain sensitivity, specificity, positive and negative predictive values, diagnostic accuracy and prevalence. Copyright © 2018 Elsevier B.V. All rights reserved.
Donegan, Ryan J; Stauffer, Anthony; Heaslet, Michael; Poliskie, Michael
Plantar plate pathology has gained noticeable attention in recent years as an etiology of lesser metatarsophalangeal joint pain. The heightened clinical awareness has led to the need for more effective diagnostic imaging accuracy. Numerous reports have established the accuracy of both magnetic resonance imaging and ultrasonography for the diagnosis of plantar plate pathology. However, no conclusions have been made regarding which is the superior imaging modality. The present study reports a case series directly comparing high-resolution dynamic ultrasonography and magnetic resonance imaging. A multicenter retrospective comparison of magnetic resonance imaging versus high-resolution dynamic ultrasonography to evaluate plantar plate pathology with surgical confirmation was conducted. The sensitivity, specificity, and positive and negative predictive values for magnetic resonance imaging were 60%, 100%, 100%, and 33%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 66%. The sensitivity, specificity, and positive and negative predictive values for high-resolution dynamic ultrasound imaging were 100%, 100%, 100%, and 100%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 100%. The p value using Fisher's exact test for magnetic resonance imaging and high-resolution dynamic ultrasonography was p = .45, a difference that was not statistically significant. High-resolution dynamic ultrasonography had greater accuracy than magnetic resonance imaging in diagnosing lesser metatarsophalangeal joint plantar plate pathology, although the difference was not statistically significant. The present case series suggests that high-resolution dynamic ultrasonography can be considered an equally accurate imaging modality for plantar plate pathology at a potential cost savings compared with magnetic resonance imaging. Therefore, high-resolution dynamic ultrasonography warrants further investigation in a prospective study. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Zhang, Li; Tang, Min; Chen, Sipan; Lei, Xiaoyan; Zhang, Xiaoling; Huan, Yi
2017-12-01
This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. • PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.
Bank, Ingrid Em; Dekker, Marieke S; Hoes, Arno W; Zuithoff, Nicolaas Pa; Verheggen, Peter Whm; de Vrey, Evelyn A; Wildbergh, Thierry X; Timmers, Leo; de Kleijn, Dominique Pv; Glatz, Jan Fc; Mosterd, Arend
2016-08-01
Timely recognition of acute coronary syndrome remains a challenge as many biomarkers, including troponin, remain negative in the first hours following the onset of chest pain. We assessed the diagnostic accuracy of heart-type fatty acid binding protein (H-FABP), a cardiac biomarker with potential value immediately post symptom onset. Prospective monocentre diagnostic accuracy study of H-FABP bedside point of care (CardioDetect®) and ELISA tests in acute coronary syndrome suspected patients presenting within 24 hours of symptom onset to the emergency department, in addition to clinical findings, electrocardiography and the currently recommended biomarker high sensitivity troponin-T (hs-cTnT). The final diagnosis of acute coronary syndrome was adjudicated by two independent cardiologists, blinded to H-FABP results. Acute coronary syndrome was diagnosed in 149 (32.9%) of 453 unselected patients with suspected acute coronary syndrome (56% men, mean age 62.6 years). Negative predictive values were similar for H-FABP point of care and ELISA tests (79% vs. 78% respectively), but inferior to initial hs-cTnT (negative predictive value 86%). The addition of H-FABP point of care results to hs-cTnT increased the negative predictive value to 89%. In a multivariable logistic regression model, H-FABP point of care and ELISA tests yielded relevant diagnostic information in addition to clinical findings and ECG (likelihood ratio test p<0.001) and increased area under the receiver operating characteristics curve (AUC; 0.82 vs. 0.84 and 0.84). This added value attenuated, however, after inclusion of hs-cTnT in the diagnostic model (AUC 0.88). In patients suspected of acute coronary syndrome presenting to the emergency department, H-FABP testing improves diagnostic accuracy in addition to clinical findings and electrocardiography. H-FABP, however, has no additional diagnostic value when hs-cTnT measurements are also available. © The European Society of Cardiology 2015.
Serina, Peter; Riley, Ian; Hernandez, Bernardo; Flaxman, Abraham D; Praveen, Devarsetty; Tallo, Veronica; Joshi, Rohina; Sanvictores, Diozele; Stewart, Andrea; Mooney, Meghan D; Murray, Christopher J L; Lopez, Alan D
2016-01-01
We believe that it is important that governments understand the reliability of the mortality data which they have at their disposable to guide policy debates. In many instances, verbal autopsy (VA) will be the only source of mortality data for populations, yet little is known about how the accuracy of VA diagnoses is affected by the reliability of the symptom responses. We previously described the effect of the duration of time between death and VA administration on VA validity. In this paper, using the same dataset, we assess the relationship between the reliability and completeness of symptom responses and the reliability and accuracy of cause of death (COD) prediction. The study was based on VAs in the Population Health Metrics Research Consortium (PHMRC) VA Validation Dataset from study sites in Bohol and Manila, Philippines and Andhra Pradesh, India. The initial interview was repeated within 3-52 months of death. Question responses were assessed for reliability and completeness between the two survey rounds. COD was predicted by Tariff Method. A sample of 4226 VAs was collected for 2113 decedents, including 1394 adults, 349 children, and 370 neonates. Mean question reliability was unexpectedly low ( kappa = 0.447): 42.5 % of responses positive at the first interview were negative at the second, and 47.9 % of responses positive at the second had been negative at the first. Question reliability was greater for the short form of the PHMRC instrument ( kappa = 0.497) and when analyzed at the level of the individual decedent ( kappa = 0.610). Reliability at the level of the individual decedent was associated with COD predictive reliability and predictive accuracy. Families give coherent accounts of events leading to death but the details vary from interview to interview for the same case. Accounts are accurate but inconsistent; different subsets of symptoms are identified on each occasion. However, there are sufficient accurate and consistent subsets of symptoms to enable the Tariff Method to assign a COD. Questions which contributed most to COD prediction were also the most reliable and consistent across repeat interviews; these have been included in the short form VA questionnaire. Accuracy and reliability of diagnosis for an individual death depend on the quality of interview. This has considerable implications for the progressive roll out of VAs into civil registration and vital statistics (CRVS) systems.
Silva, William P P; Stramandinoli-Zanicotti, Roberta T; Schussel, Juliana L; Ramos, Gyl H A; Ioshi, Sergio O; Sassi, Laurindo M
2016-11-01
Objective: This article concerns evaluation of the sensitivity, specificity and accuracy of FNAB for pre-surgical diagnosis of benign and malignant lesions of major and minor salivary glands of patients treated in the Department of Head and Neck Surgery of Erasto Gartner Hospital. Methods: This retrospective study analyzed medical records from January 2006 to December 2011 from patients with salivary gland lesions who underwent preoperative FNAB and, after surgical excision of the lesion, histopathological examination. Results: The study had a cohort of 130 cases, but 34 cases (26.2%) were considered unsatisfactory regarding cytology analyses. Based on the data, sensitivity was 66.7% (6/9), specificity was 81.6% (71/87), accuracy was 80.2% (77/96), the positive predictive value was 66,7% (6/9) and the negative predictive value was 81.6% (71/87). Conclusion: Despite the high rate of inadequate samples obtained in the FNAB in this study the technique offers high specificity, accuracy and acceptable sensitivity. Creative Commons Attribution License
Hinz, Antje; Fischer, Andrew T
2011-10-01
To compare the accuracy of ultrasonographic and radiographic examination for evaluation of articular lesions in horses. Cross-sectional study. Horses (n = 137) with articular lesions. Radiographic and ultrasonographic examinations of the affected joint(s) were performed before diagnostic or therapeutic arthroscopic surgery. Findings were recorded and compared to lesions identified during arthroscopy. In 254 joints, 432 lesions were identified by arthroscopy. The overall accuracy was 82.9% for ultrasonography and 62.2% for radiography (P < .0001) with a sensitivity of 91.4% for ultrasonography and 66.7% for radiography (P < .0001). The difference in specificity was not statistically significant (P = .2628). The negative predictive value for ultrasonography was 31.5% and 13.2% for radiography (P = .0022), the difference for the positive predictive value was not statistically significant (P = .3898). The accuracy for ultrasonography and radiography for left versus right joints was equal and corresponded with the overall results. Ultrasonographic evaluation of articular lesions was more accurate than radiographic evaluation. © Copyright 2011 by The American College of Veterinary Surgeons.
Prediction of near-term breast cancer risk using a Bayesian belief network
NASA Astrophysics Data System (ADS)
Zheng, Bin; Ramalingam, Pandiyarajan; Hariharan, Harishwaran; Leader, Joseph K.; Gur, David
2013-03-01
Accurately predicting near-term breast cancer risk is an important prerequisite for establishing an optimal personalized breast cancer screening paradigm. In previous studies, we investigated and tested the feasibility of developing a unique near-term breast cancer risk prediction model based on a new risk factor associated with bilateral mammographic density asymmetry between the left and right breasts of a woman using a single feature. In this study we developed a multi-feature based Bayesian belief network (BBN) that combines bilateral mammographic density asymmetry with three other popular risk factors, namely (1) age, (2) family history, and (3) average breast density, to further increase the discriminatory power of our cancer risk model. A dataset involving "prior" negative mammography examinations of 348 women was used in the study. Among these women, 174 had breast cancer detected and verified in the next sequential screening examinations, and 174 remained negative (cancer-free). A BBN was applied to predict the risk of each woman having cancer detected six to 18 months later following the negative screening mammography. The prediction results were compared with those using single features. The prediction accuracy was significantly increased when using the BBN. The area under the ROC curve increased from an AUC=0.70 to 0.84 (p<0.01), while the positive predictive value (PPV) and negative predictive value (NPV) also increased from a PPV=0.61 to 0.78 and an NPV=0.65 to 0.75, respectively. This study demonstrates that a multi-feature based BBN can more accurately predict the near-term breast cancer risk than with a single feature.
Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco
2010-01-01
To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.
Gamal El-Dien, Omnia; Ratcliffe, Blaise; Klápště, Jaroslav; Chen, Charles; Porth, Ilga; El-Kassaby, Yousry A
2015-05-09
Genomic selection (GS) in forestry can substantially reduce the length of breeding cycle and increase gain per unit time through early selection and greater selection intensity, particularly for traits of low heritability and late expression. Affordable next-generation sequencing technologies made it possible to genotype large numbers of trees at a reasonable cost. Genotyping-by-sequencing was used to genotype 1,126 Interior spruce trees representing 25 open-pollinated families planted over three sites in British Columbia, Canada. Four imputation algorithms were compared (mean value (MI), singular value decomposition (SVD), expectation maximization (EM), and a newly derived, family-based k-nearest neighbor (kNN-Fam)). Trees were phenotyped for several yield and wood attributes. Single- and multi-site GS prediction models were developed using the Ridge Regression Best Linear Unbiased Predictor (RR-BLUP) and the Generalized Ridge Regression (GRR) to test different assumption about trait architecture. Finally, using PCA, multi-trait GS prediction models were developed. The EM and kNN-Fam imputation methods were superior for 30 and 60% missing data, respectively. The RR-BLUP GS prediction model produced better accuracies than the GRR indicating that the genetic architecture for these traits is complex. GS prediction accuracies for multi-site were high and better than those of single-sites while multi-site predictability produced the lowest accuracies reflecting type-b genetic correlations and deemed unreliable. The incorporation of genomic information in quantitative genetics analyses produced more realistic heritability estimates as half-sib pedigree tended to inflate the additive genetic variance and subsequently both heritability and gain estimates. Principle component scores as representatives of multi-trait GS prediction models produced surprising results where negatively correlated traits could be concurrently selected for using PCA2 and PCA3. The application of GS to open-pollinated family testing, the simplest form of tree improvement evaluation methods, was proven to be effective. Prediction accuracies obtained for all traits greatly support the integration of GS in tree breeding. While the within-site GS prediction accuracies were high, the results clearly indicate that single-site GS models ability to predict other sites are unreliable supporting the utilization of multi-site approach. Principle component scores provided an opportunity for the concurrent selection of traits with different phenotypic optima.
Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.
Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina
2013-03-01
To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed sonography is positive.
Shao, Yan; Peng, Hong; Chen, Cheng; Zhu, Tao; Ji, Ming; Jiang, Wei; Zhu, Wei; Zhai, Xiang Jun; Lu, Wei
2017-04-01
Tuberculosis is one of the most common infectious diseases in China, while delayed patient finding obstructed disease control, especially for smear-negative patients. The current study was undertaken to evaluate the diagnostic accuracy of GeneXpert MTB/RIF compared with conventional methods in the detection of pulmonary tuberculosis patients. A total of 295 spot sputum samples from confirmed pulmonary tuberculosis patients were evaluated from September 2014 to June 2015. Each sample was examined by acid-fast bacillus smear microscopy, culture and GeneXpert MTB/RIF. The sputum culture on Löwenstein-Jensen (L-J) was considered as the gold-standard. After testing by smear, 68.81% (203/295) was negative and 31.19% (92/295) was positive. As the gold-standard, L-J culture detected 37.97% (112/295) positive of all specimens, while the positivity for GeneXpert MTB/RIF was 46.44% (137/295). Compared with L-J culture, the combined sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for GeneXpert MTB/RIF were 94.64%, 82.97%, 77.37% and 96.18% respectively. For smear-negative specimens, the sensitivity, specificity, PPV and NPV for GeneXpert MTB/RIF were 96.00%, 83.05%, 44.44% and 99.32%; while for smear-positive specimens, the corresponding accuracy values were 94.25%, 80.00%, 98.80% and 44.44%. The findings of study indicated that GeneXpert MTB/RIF assay demonstrated a high sensitivity in detecting Mycobacterium tuberculosis compared to smear method and a high NPV among smear negative patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Seligman, Renato; Seligman, Beatriz Graeff Santos; Konkewicz, Loriane; Dos Santos, Rodrigo Pires
2015-01-01
The Gram stain can be used to direct initial empiric antimicrobial therapy when complete culture is not available. This rapid test could prevent the initiation of inappropriate therapy and adverse outcomes. However, several studies have attempted to determine the value of the Gram stain in the diagnosis and therapy of bacterial infection in different populations of patients with ventilator-associated pneumonia (VAP) with conflicting results. The objective of this study is to evaluate the accuracy of the Gram stain in predicting the existence of Staphylococcus aureus infections from cultures of patients suspected of having VAP. This prospective single-center open cohort study enrolled 399 patients from December 2005 to December 2010. Patients suspected of having VAP by ATS IDSA criteria were included. Respiratory secretion samples were collected by tracheal aspirate (TA) for standard bacterioscopic analysis by Gram stain and culture. Respiratory secretion samples collected by tracheal aspirates of 392 patients were analyzed by Gram stain and culture. When Gram-positive cocci were arranged in clusters, the sensitivity was 68.4%, specificity 97.8%, positive predictive value 88.1% and negative predictive value 92.8% for predicting the presence of Staphylococcus aureus in culture (p < 0.001). A tracheal aspirate Gram stain can be used to rule out the presence of Staphylococcus aureus in patients with a clinical diagnosis of VAP with a 92.8% Negative Predictive Value. Therefore, 7.2% of patients with Staphylococcus aureus would not be protected by an empiric treatment that limits antimicrobial coverage to Staphylococcus aureus only when Gram positive cocci in clusters are identified.
Financial Distress Prediction Using Discrete-time Hazard Model and Rating Transition Matrix Approach
NASA Astrophysics Data System (ADS)
Tsai, Bi-Huei; Chang, Chih-Huei
2009-08-01
Previous studies used constant cut-off indicator to distinguish distressed firms from non-distressed ones in the one-stage prediction models. However, distressed cut-off indicator must shift according to economic prosperity, rather than remains fixed all the time. This study focuses on Taiwanese listed firms and develops financial distress prediction models based upon the two-stage method. First, this study employs the firm-specific financial ratio and market factors to measure the probability of financial distress based on the discrete-time hazard models. Second, this paper further focuses on macroeconomic factors and applies rating transition matrix approach to determine the distressed cut-off indicator. The prediction models are developed by using the training sample from 1987 to 2004, and their levels of accuracy are compared with the test sample from 2005 to 2007. As for the one-stage prediction model, the model in incorporation with macroeconomic factors does not perform better than that without macroeconomic factors. This suggests that the accuracy is not improved for one-stage models which pool the firm-specific and macroeconomic factors together. In regards to the two stage models, the negative credit cycle index implies the worse economic status during the test period, so the distressed cut-off point is adjusted to increase based on such negative credit cycle index. After the two-stage models employ such adjusted cut-off point to discriminate the distressed firms from non-distressed ones, their error of misclassification becomes lower than that of one-stage ones. The two-stage models presented in this paper have incremental usefulness in predicting financial distress.
Can machine-learning improve cardiovascular risk prediction using routine clinical data?
Kai, Joe; Garibaldi, Jonathan M.; Qureshi, Nadeem
2017-01-01
Background Current approaches to predict cardiovascular risk fail to identify many people who would benefit from preventive treatment, while others receive unnecessary intervention. Machine-learning offers opportunity to improve accuracy by exploiting complex interactions between risk factors. We assessed whether machine-learning can improve cardiovascular risk prediction. Methods Prospective cohort study using routine clinical data of 378,256 patients from UK family practices, free from cardiovascular disease at outset. Four machine-learning algorithms (random forest, logistic regression, gradient boosting machines, neural networks) were compared to an established algorithm (American College of Cardiology guidelines) to predict first cardiovascular event over 10-years. Predictive accuracy was assessed by area under the ‘receiver operating curve’ (AUC); and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) to predict 7.5% cardiovascular risk (threshold for initiating statins). Findings 24,970 incident cardiovascular events (6.6%) occurred. Compared to the established risk prediction algorithm (AUC 0.728, 95% CI 0.723–0.735), machine-learning algorithms improved prediction: random forest +1.7% (AUC 0.745, 95% CI 0.739–0.750), logistic regression +3.2% (AUC 0.760, 95% CI 0.755–0.766), gradient boosting +3.3% (AUC 0.761, 95% CI 0.755–0.766), neural networks +3.6% (AUC 0.764, 95% CI 0.759–0.769). The highest achieving (neural networks) algorithm predicted 4,998/7,404 cases (sensitivity 67.5%, PPV 18.4%) and 53,458/75,585 non-cases (specificity 70.7%, NPV 95.7%), correctly predicting 355 (+7.6%) more patients who developed cardiovascular disease compared to the established algorithm. Conclusions Machine-learning significantly improves accuracy of cardiovascular risk prediction, increasing the number of patients identified who could benefit from preventive treatment, while avoiding unnecessary treatment of others. PMID:28376093
Can machine-learning improve cardiovascular risk prediction using routine clinical data?
Weng, Stephen F; Reps, Jenna; Kai, Joe; Garibaldi, Jonathan M; Qureshi, Nadeem
2017-01-01
Current approaches to predict cardiovascular risk fail to identify many people who would benefit from preventive treatment, while others receive unnecessary intervention. Machine-learning offers opportunity to improve accuracy by exploiting complex interactions between risk factors. We assessed whether machine-learning can improve cardiovascular risk prediction. Prospective cohort study using routine clinical data of 378,256 patients from UK family practices, free from cardiovascular disease at outset. Four machine-learning algorithms (random forest, logistic regression, gradient boosting machines, neural networks) were compared to an established algorithm (American College of Cardiology guidelines) to predict first cardiovascular event over 10-years. Predictive accuracy was assessed by area under the 'receiver operating curve' (AUC); and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) to predict 7.5% cardiovascular risk (threshold for initiating statins). 24,970 incident cardiovascular events (6.6%) occurred. Compared to the established risk prediction algorithm (AUC 0.728, 95% CI 0.723-0.735), machine-learning algorithms improved prediction: random forest +1.7% (AUC 0.745, 95% CI 0.739-0.750), logistic regression +3.2% (AUC 0.760, 95% CI 0.755-0.766), gradient boosting +3.3% (AUC 0.761, 95% CI 0.755-0.766), neural networks +3.6% (AUC 0.764, 95% CI 0.759-0.769). The highest achieving (neural networks) algorithm predicted 4,998/7,404 cases (sensitivity 67.5%, PPV 18.4%) and 53,458/75,585 non-cases (specificity 70.7%, NPV 95.7%), correctly predicting 355 (+7.6%) more patients who developed cardiovascular disease compared to the established algorithm. Machine-learning significantly improves accuracy of cardiovascular risk prediction, increasing the number of patients identified who could benefit from preventive treatment, while avoiding unnecessary treatment of others.
Accuracy of a Mouse Bioassay for the Diagnosis of Botulism in Horses.
Johnson, A L; McAdams-Gallagher, S C; Aceto, H
2016-07-01
The laboratory diagnosis of botulism in horses traditionally has relied upon the mouse bioassay (MBA). The accuracy of this test for the diagnosis of botulism in horses is unknown. Our goal was to determine the sensitivity, specificity, positive predictive value, and negative predictive value of the MBA on laboratory-processed fecal and gastrointestinal samples for foals and adult horses. Cases included all horses with a final clinical diagnosis of botulism that were admitted between 1986 and 2011 and had MBA testing performed. Controls included horses without botulism that were admitted during the same time period and had MBA testing performed. Retrospective study. Horses suspected of having botulism had fecal or (less commonly) gastrointestinal content samples tested using MBA. For every hospitalized botulism suspect, control samples were obtained from ≥1 additional hospitalized horses not suspected to have botulism. One hundred and twenty-nine adult horses and 253 adult controls were identified. Overall sensitivity of the MBA was only 32% but specificity was 97%. Forty-three foal cases and 21 foal controls were evaluated; sensitivity of the MBA was 53% and specificity was 100%. Positive predictive value was substantially higher (100% for foals and 89% for adults) than negative predictive value (51% for foals and 67% for adults). Mouse bioassay has low sensitivity but high specificity for the diagnosis of botulism in horses. Positive results are highly suggestive of botulism but negative results do not exclude the diagnosis. Unaffected horses and foals rarely shed C. botulinum in their feces. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Schreck, David M; Fishberg, Robert D
2014-01-01
Objective A new cardiac “electrical” biomarker (CEB) for detection of 12-lead electrocardiogram (ECG) changes indicative of acute myocardial ischemic injury has been identified. Objective was to test CEB diagnostic accuracy. Methods This is a blinded, observational retrospective case-control, noninferiority study. A total of 508 ECGs obtained from archived digital databases were interpreted by cardiologist and emergency physician (EP) blinded reference standards for presence of acute myocardial ischemic injury. CEB was constructed from three ECG cardiac monitoring leads using nonlinear modeling. Comparative active controls included ST voltage changes (J-point, ST area under curve) and a computerized ECG interpretive algorithm (ECGI). Training set of 141 ECGs identified CEB cutoffs by receiver-operating-characteristic (ROC) analysis. Test set of 367 ECGs was analyzed for validation. Poor-quality ECGs were excluded. Sensitivity, specificity, and negative and positive predictive values were calculated with 95% confidence intervals. Adjudication was performed by consensus. Results CEB demonstrated noninferiority to all active controls by hypothesis testing. CEB adjudication demonstrated 85.3–94.4% sensitivity, 92.5–93.0% specificity, 93.8–98.6% negative predictive value, and 74.6–83.5% positive predictive value. CEB was superior against all active controls in EP analysis, and against ST area under curve and ECGI by cardiologist. Conclusion CEB detects acute myocardial ischemic injury with high diagnostic accuracy. CEB is instantly constructed from three ECG leads on the cardiac monitor and displayed instantly allowing immediate cost-effective identification of patients with acute ischemic injury during cardiac rhythm monitoring. PMID:24118724
Bolandparvaz, Shahram; Moharamzadeh, Payman; Jamali, Kazem; Pouraghaei, Mahboob; Fadaie, Maryam; Sefidbakht, Sepideh; Shahsavari, Kavous
2013-11-01
Long bone fractures are currently diagnosed using radiography, but radiography has some disadvantages (radiation and being time consuming). The present study compared the diagnostic accuracy of bedside ultrasound and radiography in multiple trauma patients at the emergency department (ED). The study assessed 80 injured patients with multiple trauma from February 2011 to July 2012. The patients were older than 18 years and triaged to the cardiopulmonary resuscitation ward of the ED. Bedside ultrasound and radiography were conducted for them. The findings were separately and blindly assessed by 2 radiologists. Sensitivity, specificity, the positive and negative predictive value, and κ coefficient were measured to assess the accuracy and validity of ultrasound as compared with radiography. The sensitivity of ultrasound for diagnosis of limb bone fractures was not high enough and ranged between 55% and 75% depending on the fracture site. The specificity of this diagnostic method had an acceptable range of 62% to 84%. Ultrasound negative prediction value was higher than other indices under study and ranged between 73% and 83%, but its positive prediction value varied between 33.3% and 71%. The κ coefficient for diagnosis of long bone fractures of upper limb (κ = 0.58) and upper limb joints (κ = 0.47) and long bones of lower limb (κ = 0.52) was within the medium range. However, the value for diagnosing fractures of lower limb joints (κ = 0.47) was relatively low. Bedside ultrasound is not a reliable method for diagnosing fractures of upper and lower limb bones compared with radiography. © 2013 Elsevier Inc. All rights reserved.
Remmers, John E; Topor, Zbigniew; Grosse, Joshua; Vranjes, Nikola; Mosca, Erin V; Brant, Rollin; Bruehlmann, Sabina; Charkhandeh, Shouresh; Zareian Jahromi, Seyed Abdolali
2017-07-15
Mandibular protruding oral appliances represent a potentially important therapy for obstructive sleep apnea (OSA). However, their clinical utility is limited by a less-than-ideal efficacy rate and uncertainty regarding an efficacious mandibular position, pointing to the need for a tool to assist in delivery of the therapy. The current study assesses the ability to prospectively identify therapeutic responders and determine an efficacious mandibular position. Individuals (n = 202) with OSA participated in a blinded, 2-part investigation. A system for identifying therapeutic responders was developed in part 1 (n = 149); the predictive accuracy of this system was prospectively evaluated on a new population in part 2 (n = 53). Each participant underwent a 2-night, in-home feedback-controlled mandibular positioner (FCMP) test, followed by treatment with a custom oral appliance and an outcome study with the oral appliance in place. A machine learning classification system was trained to predict therapeutic outcome on data obtained from FCMP studies on part 1 participants. The accuracy of this trained system was then evaluated on part 2 participants by examining the agreement between prospectively predicted outcome and observed outcome. A predicted efficacious mandibular position was derived from each FCMP study. Predictive accuracy was as follows: sensitivity 85%; specificity 93%; positive predictive value 97%; and negative predictive value 72%. Of participants correctly predicted to respond to therapy, the predicted mandibular protrusive position proved efficacious in 86% of cases. An unattended, in-home FCMP test prospectively identifies individuals with OSA who will respond to oral appliance therapy and provides an efficacious mandibular position. The trial that this study reports on is registered on www.clinicaltrials.gov, ID NCT03011762, study name: Feasibility and Predictive Accuracy of an In-Home Computer Controlled Mandibular Positioner in Identifying Favourable Candidates for Oral Appliance Therapy. © 2017 American Academy of Sleep Medicine
Ederveen, J C; van Berckel, M M G; Nienhuijs, S W; Weber, R J P; Nederend, J
2018-06-04
Internal herniation, a serious complication after bariatric surgery, is challenging to diagnose. The aim of this study was to determine the accuracy of abdominal CT in diagnosing internal herniation. The study included consecutive patients who had undergone laparoscopic gastric bypass surgery between 1 January 2011 and 1 January 2015 at a bariatric centre of excellence. To select patients suspected of having internal herniation, reports of abdominal CT and reoperations up to 1 January 2017 were screened. CT was presumed negative for internal herniation if no follow-up CT or reoperation was performed within 90 days after the initial CT, or no internal herniation was found during reoperation. The accuracy of abdominal CT in diagnosing internal herniation was calculated using two-way contingency tables. A total of 1475 patients were included (84·7 per cent women, mean age 46·5 years, median initial BMI 41·8 kg/m 2 ). CT and/or reoperation was performed in 192 patients (13·0 per cent) in whom internal herniation was suspected. Internal herniation was proven laparoscopically in 37 of these patients. The incidence of internal herniation was 2·5 per cent. An analysis by complaint included a total of 265 episodes, for which 247 CT scans were undertaken. CT was not used to investigate 18 episodes, but internal herniation was encountered in one-third of these during reoperation. Combining the follow-up and intraoperative findings, the accuracy of CT for internal herniation had a sensitivity of 83·8 (95 per cent c.i. 67·3 to 93·2) per cent, a specificity of 87·1 (81·7 to 91·2) per cent, a positive predictive value of 53·4 (40·0 to 66·5) per cent and a negative predictive value of 96·8 (92·9 to 98·7) per cent. Abdominal CT is an important tool in diagnosing internal herniation, with a high specificity and a high negative predictive value. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.
Nkonya, Daniel Ndaki; Tarimo, Donath Samuel; Kishimba, Rogath Saika
2016-01-01
Malaria diagnosis is known to be non-specific because of the overlap of symptoms of malaria with other infectious diseases that is made worse with declining malaria burden. Though the use of malaria rapid diagnostic test (mRDT) for malaria confirmation has universally been adopted, malaria decline may alter performance of mRDT. This study examined accuracy of clinical diagnosis and mRDT and its influence on prescription for febrile underfives. A cross-sectional study of 600 underfives was carried out in 6 randomly selected health facilities in Misungwi district, Mwanza; from November - December 2014. Consecutive underfives with a fever consultation were recruited: for each fever and the clinical diagnosis entertained were recorded. Parasitological confirmation of malaria was done by mRDT and microscopic examination of finger prick blood samples. Treatment was based on mRDT results, drugs prescribed recorded. Accuracy of clinical diagnosis and mRDT in predicting malaria was assessed by performance indices against microscopy. Antimalarial and antibiotics prescriptions were assessed against parasitological findings. Clinically, 37.2% had malaria; 32.8% were mRDTpositive and 17.0% microscopically positive. Sensitivity of clinical diagnosis was very high (97.0% [95%CI: 91.0-99.2]); specificity 66.7% [95%CI: 62.3-70.8], and positive predictive value 37.4% (95%CI: 31.6-43.5). Sensitivity of mRDTwas very high (99.0% [95%CI: 93.9-99.9]), specificity (80.7% [95%CI: 76.9-84.0]), positive predictive value 51.3% [95% CI: 44.1-58.4]) and negative predictive 99.75% [95%CI: 99.4-100.0]. Those receiving antimalarial prescription, 75.0% were mRDT positive; 39.4% microscopically positive. Those receiving antibiotic, 78.8% were mRDT negative; 90.1% microscopically negative. Decline in malaria lowered specificity of mRDT to < 95% against WHO recommendation. Though adherence to mRDT results was high, there was over prescription of antibiotics.
Nkonya, Daniel Ndaki; Tarimo, Donath Samuel; Kishimba, Rogath Saika
2016-01-01
Introduction Malaria diagnosis is known to be non-specific because of the overlap of symptoms of malaria with other infectious diseases that is made worse with declining malaria burden. Though the use of malaria rapid diagnostic test (mRDT) for malaria confirmation has universally been adopted, malaria decline may alter performance of mRDT. This study examined accuracy of clinical diagnosis and mRDT and its influence on prescription for febrile underfives. Methods A cross-sectional study of 600 underfives was carried out in 6 randomly selected health facilities in Misungwi district, Mwanza; from November - December 2014. Consecutive underfives with a fever consultation were recruited: for each fever and the clinical diagnosis entertained were recorded. Parasitological confirmation of malaria was done by mRDT and microscopic examination of finger prick blood samples. Treatment was based on mRDT results, drugs prescribed recorded. Accuracy of clinical diagnosis and mRDT in predicting malaria was assessed by performance indices against microscopy. Antimalarial and antibiotics prescriptions were assessed against parasitological findings. Results Clinically, 37.2% had malaria; 32.8% were mRDTpositive and 17.0% microscopically positive. Sensitivity of clinical diagnosis was very high (97.0% [95%CI: 91.0-99.2]); specificity 66.7% [95%CI: 62.3-70.8], and positive predictive value 37.4% (95%CI: 31.6-43.5). Sensitivity of mRDTwas very high (99.0% [95%CI: 93.9-99.9]), specificity (80.7% [95%CI: 76.9-84.0]), positive predictive value 51.3% [95% CI: 44.1-58.4]) and negative predictive 99.75% [95%CI: 99.4-100.0]. Those receiving antimalarial prescription, 75.0% were mRDT positive; 39.4% microscopically positive. Those receiving antibiotic, 78.8% were mRDT negative; 90.1% microscopically negative. Conclusion Decline in malaria lowered specificity of mRDT to < 95% against WHO recommendation. Though adherence to mRDT results was high, there was over prescription of antibiotics. PMID:28250872
Triple Test in Carcinoma Breast
Sameer; Mukherjee, Arindam
2014-01-01
Introduction: The commonest clinical presentation in majority of breast pathology is a lump. A definite diagnosis of breast lump is very important for the surgeon to decide on the final course of treatment and also saves the patient from unnecessary physical, emotional and psychological trauma if there is a definite preoperative diagnosis of benign lesion. The present study was done to evaluate the effectiveness and relevance of “TRIPLE TEST”in diagnosis of carcinoma breast in rural labour class population. Materials and Methods: The present study was a prospective study conducted on patients over 35 years of age having palpable breast lumps presenting in the out patient department of general surgery, ESI Hospital Basaidarapur New Delhi, India. The duration of study was from May 2007 to June 2009 and a total of 100 cases were studied. Each patient was subjected to a detailed history, clinical breast examination ,diagnostic mammography and FNAC. In this study, the results of each modality was divided in three groups: benign, suspicious and malignant. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of each test was calculated individually and as combined. Result: Out of 100 patients enrolled in this study, 60 cases were benign and 40 cases were of malignant breast disease. The age of patients with carcinoma breast in the series varied from 35 years to 70 years. The highest incidence of malignancy noted was 30% in 41-50 years age group (4th decade) followed by 27.5% in 51-60 years age group (5th decade). The sensitivity of clinical examination was found to be 75%, specificity was 83.3%, positive predictive value (PPV) of 75% and diagnostic accuracy of 80%. The sensitivity, specificity, positive predictive value and diagnostic accuracy of mammography was calculated and was found to be 94.9% , 90% , 86% and 92% respectively. The sensitivity, specificity, positive predictive value and diagnostic accuracy of FNAC was 94.7%, 98.3%, 97.3% and 96.6% respectively. Out of 100 cases triple test was concordant (all three test either benign or malignant) in 80 cases, all the benign cases detected by triple test were benign on final biopsy i.e. 100% specificity and 100% negative predictive value. Conclusion: TTS is an accurate and least invasive diagnostic test based on which definitive treatment can be initiated. PMID:25478391
Paz-Alonso, Pedro M; Goodman, Gail S; Ibabe, Izaskun
2013-01-01
This study investigated effects of misleading post-event information, delay, and centrality definition on eyewitness memory and suggestibility for a negative event (a vividly filmed murder). Either immediately or 2 weeks after viewing the film, 93 adults read a (misleading or control) narrative about the event and then completed a recognition memory test. Misinformation acceptance was operative, but strong evidence for memory malleability was lacking. Compliance predicted misinformation effects, especially on the delayed test. Although accuracy was generally higher for central than peripheral information, centrality criteria influenced the pattern of results. Self-report of greater distress was associated with better recognition accuracy. The results suggest that use of different centrality definitions may partly explain inconsistencies across studies of memory and suggestibility for central and peripheral information. Moreover, social factors appeared, at least in part, to influence misinformation effects for the highly negative event, especially as memory faded. Implications for eyewitness memory and suggestibility are discussed. Copyright © 2013 John Wiley & Sons, Ltd.
Discovering Peripheral Arterial Disease Cases from Radiology Notes Using Natural Language Processing
Savova, Guergana K.; Fan, Jin; Ye, Zi; Murphy, Sean P.; Zheng, Jiaping; Chute, Christopher G.; Kullo, Iftikhar J.
2010-01-01
As part of the Electronic Medical Records and Genomics Network, we applied, extended and evaluated an open source clinical Natural Language Processing system, Mayo’s Clinical Text Analysis and Knowledge Extraction System, for the discovery of peripheral arterial disease cases from radiology reports. The manually created gold standard consisted of 223 positive, 19 negative, 63 probable and 150 unknown cases. Overall accuracy agreement between the system and the gold standard was 0.93 as compared to a named entity recognition baseline of 0.46. Sensitivity for the positive, probable and unknown cases was 0.93–0.96, and for the negative cases was 0.72. Specificity and negative predictive value for all categories were in the 90’s. The positive predictive value for the positive and unknown categories was in the high 90’s, for the negative category was 0.84, and for the probable category was 0.63. We outline the main sources of errors and suggest improvements. PMID:21347073
Asymmetric bagging and feature selection for activities prediction of drug molecules.
Li, Guo-Zheng; Meng, Hao-Hua; Lu, Wen-Cong; Yang, Jack Y; Yang, Mary Qu
2008-05-28
Activities of drug molecules can be predicted by QSAR (quantitative structure activity relationship) models, which overcomes the disadvantages of high cost and long cycle by employing the traditional experimental method. With the fact that the number of drug molecules with positive activity is rather fewer than that of negatives, it is important to predict molecular activities considering such an unbalanced situation. Here, asymmetric bagging and feature selection are introduced into the problem and asymmetric bagging of support vector machines (asBagging) is proposed on predicting drug activities to treat the unbalanced problem. At the same time, the features extracted from the structures of drug molecules affect prediction accuracy of QSAR models. Therefore, a novel algorithm named PRIFEAB is proposed, which applies an embedded feature selection method to remove redundant and irrelevant features for asBagging. Numerical experimental results on a data set of molecular activities show that asBagging improve the AUC and sensitivity values of molecular activities and PRIFEAB with feature selection further helps to improve the prediction ability. Asymmetric bagging can help to improve prediction accuracy of activities of drug molecules, which can be furthermore improved by performing feature selection to select relevant features from the drug molecules data sets.
Labrenz, Franziska; Icenhour, Adriane; Benson, Sven; Elsenbruch, Sigrid
2015-01-01
As a fundamental learning process, fear conditioning promotes the formation of associations between predictive cues and biologically significant signals. In its application to pain, conditioning may provide important insight into mechanisms underlying pain-related fear, although knowledge especially in interoceptive pain paradigms remains scarce. Furthermore, while the influence of contingency awareness on excitatory learning is subject of ongoing debate, its role in pain-related acquisition is poorly understood and essentially unknown regarding extinction as inhibitory learning. Therefore, we addressed the impact of contingency awareness on learned emotional responses to pain- and safety-predictive cues in a combined dataset of two pain-related conditioning studies. In total, 75 healthy participants underwent differential fear acquisition, during which rectal distensions as interoceptive unconditioned stimuli (US) were repeatedly paired with a predictive visual cue (conditioned stimulus; CS+) while another cue (CS−) was presented unpaired. During extinction, both CS were presented without US. CS valence, indicating learned emotional responses, and CS-US contingencies were assessed on visual analog scales (VAS). Based on an integrative measure of contingency accuracy, a median-split was performed to compare groups with low vs. high contingency accuracy regarding learned emotional responses. To investigate predictive value of contingency accuracy, regression analyses were conducted. Highly accurate individuals revealed more pronounced negative emotional responses to CS+ and increased positive responses to CS− when compared to participants with low contingency accuracy. Following extinction, highly accurate individuals had fully extinguished pain-predictive cue properties, while exhibiting persistent positive emotional responses to safety signals. In contrast, individuals with low accuracy revealed equally positive emotional responses to both, CS+ and CS−. Contingency accuracy predicted variance in the formation of positive responses to safety cues while no predictive value was found for danger cues following acquisition and for neither cue following extinction. Our findings underscore specific roles of learned danger and safety in pain-related acquisition and extinction. Contingency accuracy appears to distinctly impact learned emotional responses to safety and danger cues, supporting aversive learning to occur independently from CS-US awareness. The interplay of cognitive and emotional factors in shaping excitatory and inhibitory pain-related learning may contribute to altered pain processing, underscoring its clinical relevance in chronic pain. PMID:26640433
Labrenz, Franziska; Icenhour, Adriane; Benson, Sven; Elsenbruch, Sigrid
2015-01-01
As a fundamental learning process, fear conditioning promotes the formation of associations between predictive cues and biologically significant signals. In its application to pain, conditioning may provide important insight into mechanisms underlying pain-related fear, although knowledge especially in interoceptive pain paradigms remains scarce. Furthermore, while the influence of contingency awareness on excitatory learning is subject of ongoing debate, its role in pain-related acquisition is poorly understood and essentially unknown regarding extinction as inhibitory learning. Therefore, we addressed the impact of contingency awareness on learned emotional responses to pain- and safety-predictive cues in a combined dataset of two pain-related conditioning studies. In total, 75 healthy participants underwent differential fear acquisition, during which rectal distensions as interoceptive unconditioned stimuli (US) were repeatedly paired with a predictive visual cue (conditioned stimulus; CS(+)) while another cue (CS(-)) was presented unpaired. During extinction, both CS were presented without US. CS valence, indicating learned emotional responses, and CS-US contingencies were assessed on visual analog scales (VAS). Based on an integrative measure of contingency accuracy, a median-split was performed to compare groups with low vs. high contingency accuracy regarding learned emotional responses. To investigate predictive value of contingency accuracy, regression analyses were conducted. Highly accurate individuals revealed more pronounced negative emotional responses to CS(+) and increased positive responses to CS(-) when compared to participants with low contingency accuracy. Following extinction, highly accurate individuals had fully extinguished pain-predictive cue properties, while exhibiting persistent positive emotional responses to safety signals. In contrast, individuals with low accuracy revealed equally positive emotional responses to both, CS(+) and CS(-). Contingency accuracy predicted variance in the formation of positive responses to safety cues while no predictive value was found for danger cues following acquisition and for neither cue following extinction. Our findings underscore specific roles of learned danger and safety in pain-related acquisition and extinction. Contingency accuracy appears to distinctly impact learned emotional responses to safety and danger cues, supporting aversive learning to occur independently from CS-US awareness. The interplay of cognitive and emotional factors in shaping excitatory and inhibitory pain-related learning may contribute to altered pain processing, underscoring its clinical relevance in chronic pain.
Farinati, F; Cardin, F; Di Mario, F; Sava, G A; Piccoli, A; Costa, F; Penon, G; Naccarato, R
1987-08-01
The endoscopic diagnosis of chronic atrophic gastritis is often underestimated, and most of the procedures adopted to increase diagnostic accuracy are time consuming and complex. In this study, we evaluated the usefulness of the determination of gastric juice pH by means of litmus paper. Values obtained by this method correlate well with gastric acid secretory capacity as measured by gastric acid analysis (r = -0.64, p less than 0.001) and are not affected by the presence of bile. Gastric juice pH determination increases sensitivity and other diagnostic parameters such as performance index (Youden J test), positive predictive value, and post-test probability difference by 50%. Furthermore, the negative predictive value is very high, the probability of missing a patient with chronic atrophic gastritis with this simple method being 2% for fundic and 15% for antral atrophic change. We conclude that gastric juice pH determination, which substantially increases diagnostic accuracy and is very simple to perform, should be routinely adopted.
Crespo-García, Maité; Zeiller, Monika; Leupold, Claudia; Kreiselmeyer, Gernot; Rampp, Stefan; Hamer, Hajo M; Dalal, Sarang S
2016-11-15
Human hippocampal theta oscillations play a key role in accurate spatial coding. Associative encoding involves similar hippocampal networks but, paradoxically, is also characterized by theta power decreases. Here, we investigated how theta activity relates to associative encoding of place contexts resulting in accurate navigation. Using MEG, we found that slow-theta (2-5Hz) power negatively correlated with subsequent spatial accuracy for virtual contextual locations in posterior hippocampus and other cortical structures involved in spatial cognition. A rare opportunity to simultaneously record MEG and intracranial EEG in an epilepsy patient provided crucial insights: during power decreases, slow-theta in right anterior hippocampus and left inferior frontal gyrus phase-led the left temporal cortex and predicted spatial accuracy. Our findings indicate that decreased slow-theta activity reflects local and long-range neural mechanisms that encode accurate spatial contexts, and strengthens the view that local suppression of low-frequency activity is essential for more efficient processing of detailed information. Copyright © 2016 Elsevier Inc. All rights reserved.
Space debris tracking at San Fernando laser station
NASA Astrophysics Data System (ADS)
Catalán, M.; Quijano, M.; Pazos, A.; Martín Davila, J.; Cortina, L. M.
2016-12-01
For years to come space debris will be a major issue for society. It has a negative impact on active artificial satellites, having implications for future missions. Tracking space debris as accurately as possible is the first step towards controlling this problem, yet it presents a challenge for science. The main limitation is the relatively low accuracy of the methods used to date for tracking these objects. Clearly, improving the predicted orbit accuracy is crucial (avoiding unnecessary anti-collision maneuvers). A new field of research was recently instituted by our satellite laser ranging station: tracking decommissioned artificial satellites equipped with retroreflectors. To this end we work in conjunction with international space agencies which provide increasing attention to this problem. We thus proposed to share our time-schedule of use of the satellite laser ranging station for obtaining data that would make orbital element predictions far more accurate (meter accuracy), whilst maintaining our tracking routines for active satellites. This manuscript reports on the actions carried out so far.
Theron, Grant; Pooran, Anil; Peter, Jonny; van Zyl-Smit, Richard; Mishra, Hridesh Kumar; Meldau, Richard; Calligaro, Greg; Allwood, Brian; Sharma, Surendra Kumar; Dawson, Rod; Dheda, Keertan
2017-01-01
Information regarding the utility of adjunct diagnostic tests in combination with Xpert MTB/RIF (Cepheid, Sunnyvale, CA, USA) is limited. We hypothesised adjunct tests could enhance accuracy and/or reduce the cost of tuberculosis (TB) diagnosis prior to MTB/RIF testing, and rule-in or rule-out TB in MTB/RIF-negative individuals. We assessed the accuracy and/or laboratory-associated cost of diagnosis of smear microscopy, chest radiography (CXR) and interferon-γ release assays (IGRAs; T-SPOT-TB (Oxford Immunotec, Oxford, UK) and QuantiFERON-TB Gold In-Tube (Cellestis, Chadstone, Australia)) combined with MTB/RIF for TB in 480 patients in South Africa. When conducted prior to MTB/RIF: 1) smear microscopy followed by MTB/RIF (if smear negative) had the lowest cost of diagnosis of any strategy investigated; 2) a combination of smear microscopy, CXR (if smear negative) and MTB/RIF (if imaging compatible with active TB) did not further reduce the cost per TB case diagnosed; and 3) a normal CXR ruled out TB in 18% of patients (57 out of 324; negative predictive value (NPV) 100%). When downstream adjunct tests were applied to MTB/RIF-negative individuals, radiology ruled out TB in 24% (56 out of 234; NPV 100%), smear microscopy ruled in TB in 21% (seven out of 24) of culture-positive individuals and IGRAs were not useful in either context. In resource-poor settings, smear microscopy combined with MTB/RIF had the highest accuracy and lowest cost of diagnosis compared to either technique alone. In MTB/RIF-negative individuals, CXR has poor rule-in value but can reliably rule out TB in approximately one in four cases. These data inform upon the programmatic utility of MTB/RIF in high-burden settings. PMID:22075479
Smith, Eric E; Kent, David M; Bulsara, Ketan R; Leung, Lester Y; Lichtman, Judith H; Reeves, Mathew J; Towfighi, Amytis; Whiteley, William N; Zahuranec, Darin B
2018-03-01
Endovascular thrombectomy is a highly efficacious treatment for large vessel occlusion (LVO). LVO prediction instruments, based on stroke signs and symptoms, have been proposed to identify stroke patients with LVO for rapid transport to endovascular thrombectomy-capable hospitals. This evidence review committee was commissioned by the American Heart Association/American Stroke Association to systematically review evidence for the accuracy of LVO prediction instruments. Medline, Embase, and Cochrane databases were searched on October 27, 2016. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy-2 tool. Thirty-six relevant studies were identified. Most studies (21 of 36) recruited patients with ischemic stroke, with few studies in the prehospital setting (4 of 36) and in populations that included hemorrhagic stroke or stroke mimics (12 of 36). The most frequently studied prediction instrument was the National Institutes of Health Stroke Scale. Most studies had either some risk of bias or unclear risk of bias. Reported discrimination of LVO mostly ranged from 0.70 to 0.85, as measured by the C statistic. In meta-analysis, sensitivity was as high as 87% and specificity was as high as 90%, but no threshold on any instruments predicted LVO with both high sensitivity and specificity. With a positive LVO prediction test, the probability of LVO could be 50% to 60% (depending on the LVO prevalence in the population), but the probability of LVO with a negative test could still be ≥10%. No scale predicted LVO with both high sensitivity and high specificity. Systems that use LVO prediction instruments for triage will miss some patients with LVO and milder stroke. More prospective studies are needed to assess the accuracy of LVO prediction instruments in the prehospital setting in all patients with suspected stroke, including patients with hemorrhagic stroke and stroke mimics. © 2018 American Heart Association, Inc.
Safari, Saeed; Radfar, Fatemeh; Baratloo, Alireza
2018-05-01
This study aimed to compare the diagnostic accuracy of NEXUS chest and Thoracic Injury Rule out criteria (TIRC) models in predicting the risk of intra-thoracic injuries following blunt multiple trauma. In this diagnostic accuracy study, using the 2 mentioned models, blunt multiple trauma patients over the age of 15 years presenting to emergency department were screened regarding the presence of intra-thoracic injuries that are detectable via chest x-ray and screening performance characteristics of the models were compared. In this study, 3118 patients with the mean (SD) age of 37.4 (16.9) years were studied (57.4% male). Based on TIRC and NEXUS chest, respectively, 1340 (43%) and 1417 (45.4%) patients were deemed in need of radiography performance. Sensitivity, specificity, and positive and negative predictive values of TIRC were 98.95%, 62.70%, 21.19% and 99.83%. These values were 98.61%, 59.94%, 19.97% and 99.76%, for NEXUS chest, respectively. Accuracy of TIRC and NEXUS chest models were 66.04 (95% CI: 64.34-67.70) and 63.50 (95% CI: 61.78-65.19), respectively. TIRC and NEXUS chest models have proper and similar sensitivity in prediction of blunt traumatic intra-thoracic injuries that are detectable via chest x-ray. However, TIRC had a significantly higher specificity in this regard. Copyright © 2018 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Kiel, Elizabeth J.; Buss, Kristin A.
2011-01-01
Early social withdrawal and protective parenting predict a host of negative outcomes, warranting examination of their development. Mothers' accurate anticipation of their toddlers' fearfulness may facilitate transactional relations between toddler fearful temperament and protective parenting, leading to these outcomes. Currently, we followed 93…
Singh, Jay P; Doll, Helen; Grann, Martin
2012-01-01
Objective To investigate the predictive validity of tools commonly used to assess the risk of violence, sexual, and criminal behaviour. Design Systematic review and tabular meta-analysis of replication studies following PRISMA guidelines. Data sources PsycINFO, Embase, Medline, and United States Criminal Justice Reference Service Abstracts. Review methods We included replication studies from 1 January 1995 to 1 January 2011 if they provided contingency data for the offending outcome that the tools were designed to predict. We calculated the diagnostic odds ratio, sensitivity, specificity, area under the curve, positive predictive value, negative predictive value, the number needed to detain to prevent one offence, as well as a novel performance indicator—the number safely discharged. We investigated potential sources of heterogeneity using metaregression and subgroup analyses. Results Risk assessments were conducted on 73 samples comprising 24 847 participants from 13 countries, of whom 5879 (23.7%) offended over an average of 49.6 months. When used to predict violent offending, risk assessment tools produced low to moderate positive predictive values (median 41%, interquartile range 27-60%) and higher negative predictive values (91%, 81-95%), and a corresponding median number needed to detain of 2 (2-4) and number safely discharged of 10 (4-18). Instruments designed to predict violent offending performed better than those aimed at predicting sexual or general crime. Conclusions Although risk assessment tools are widely used in clinical and criminal justice settings, their predictive accuracy varies depending on how they are used. They seem to identify low risk individuals with high levels of accuracy, but their use as sole determinants of detention, sentencing, and release is not supported by the current evidence. Further research is needed to examine their contribution to treatment and management. PMID:22833604
Koch, Stefan P.; Hägele, Claudia; Haynes, John-Dylan; Heinz, Andreas; Schlagenhauf, Florian; Sterzer, Philipp
2015-01-01
Functional neuroimaging has provided evidence for altered function of mesolimbic circuits implicated in reward processing, first and foremost the ventral striatum, in patients with schizophrenia. While such findings based on significant group differences in brain activations can provide important insights into the pathomechanisms of mental disorders, the use of neuroimaging results from standard univariate statistical analysis for individual diagnosis has proven difficult. In this proof of concept study, we tested whether the predictive accuracy for the diagnostic classification of schizophrenia patients vs. healthy controls could be improved using multivariate pattern analysis (MVPA) of regional functional magnetic resonance imaging (fMRI) activation patterns for the anticipation of monetary reward. With a searchlight MVPA approach using support vector machine classification, we found that the diagnostic category could be predicted from local activation patterns in frontal, temporal, occipital and midbrain regions, with a maximal cluster peak classification accuracy of 93% for the right pallidum. Region-of-interest based MVPA for the ventral striatum achieved a maximal cluster peak accuracy of 88%, whereas the classification accuracy on the basis of standard univariate analysis reached only 75%. Moreover, using support vector regression we could additionally predict the severity of negative symptoms from ventral striatal activation patterns. These results show that MVPA can be used to substantially increase the accuracy of diagnostic classification on the basis of task-related fMRI signal patterns in a regionally specific way. PMID:25799236
Lin, Peiliang; Huang, Xiaoming; Zheng, Chushan; Cai, Qian; Guan, Zhong; Liang, Faya; Zheng, Yiqing
2017-01-01
The aim of this study was to evaluate the predictive value of magnetic resonance imaging (MRI) in detecting thyroid gland invasion (TGI) in patients with advanced laryngeal or hypopharyngeal carcinoma. In a retrospective chart review, 41 patients with advanced laryngeal or hypopharyngeal carcinoma underwent MRI scan before total laryngectomy and ipsilateral or bilateral thyroidectomy during the past 5 years. The MRI findings were compared with the postoperative pathological results. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Among the 41 patients, 3 had thyroid gland invasion in postoperative pathological results. MRI correctly predicted the absence of TGI in 37 of 38 patients and TGI in all 3 patients. The sensitivity, specificity, PPV, and NPV of MRI were 100.0, 97.4, 75.0, and 100 %, respectively, with the diagnostic accuracy of 97.6 %. In consideration of the high negative predictive value of MRI, it may help surgeons selectively preserve thyroid gland in total laryngectomy and reduce the incidence of hypothyroidism and hypoparathyroidism postoperatively.
Evaluation of brush cytology and DNA image cytometry for the detection of cancer of the oral cavity.
Kaur, Manveen; Handa, Uma; Mohan, Harsh; Dass, Arjun
2016-03-01
Cancer of the oral cavity is the sixth most common malignancy reported worldwide. This study was undertaken to evaluate the efficacy of brush cytology and the adjunctive role of DNA image cytometry (ICM) in the diagnosis of oral cancer. Oral brush smears and biopsy were obtained from 100 consecutive patients presenting with suspicious oral lesions. DNA-ICM was performed on 96 cytology smears which had adequate cellularity. On cytology, 54 cases were benign, 36 were malignant, 6 were suspicious for malignancy, and 4 were inadequate due to scanty cellularity. On histopathologic examination, 49 cases were diagnosed as squamous cell carcinoma and 51 cases as benign. The sensitivity of brush cytology for the detection of cancer was 83.3% and the specificity was 95.8%. The positive and negative predictive values were 95.2% and 85.2%, respectively, with a diagnostic accuracy of 86%. Out of 96 cases analyzed by image analysis to assess DNA ploidy, 33 cases were aneuploid and 63 were diploid. The sensitivity, specificity, positive predictive value, and negative predictive value of DNA-ICM were 68.7%, 100%, 100%, and 76.1%, respectively, giving a diagnostic accuracy of 81%. The combination of cytology and DNA cytometry increased the sensitivity to 92% and specificity to 100%. The study demonstrates the usefulness of DNA-ICM as an adjunct to brush cytology to diagnose oral cancer. It reduces the false negative cases on cytology and also adds to objectivity in cytologically doubtful cases. © 2016 Wiley Periodicals, Inc.
Sert Kuniyoshi, Fatima H.; Zellmer, Mark R.; Calvin, Andrew D.; Lopez-Jimenez, Francisco; Albuquerque, Felipe N.; van der Walt, Christelle; Trombetta, Ivani C; Caples, Sean M.; Shamsuzzaman, Abu S.; Bukartyk, Jan; Konecny, Tomas; Gami, Apoor S.; Kara, Tomas
2011-01-01
Background: The Berlin Questionnaire (BQ) has been used to identify patients at high risk for sleep-disordered breathing (SDB) in a variety of populations. However, there are no data regarding the validity of the BQ in detecting the presence of SDB in patients after myocardial infarction (MI). The aim of this study was to determine the performance of the BQ in patients after MI. Methods: We conducted a cross-sectional study of 99 patients who had an MI 1 to 3 months previously. The BQ was administered, scored using the published methods, and followed by completed overnight polysomnography as the “gold standard.” SDB was defined as an apnea-hypopnea index of ≥ 5 events/h. The sensitivity, specificity, and positive and negative predictive values of the BQ were calculated. Results: Of the 99 patients, the BQ identified 64 (65%) as being at high-risk for having SDB. Overnight polysomnography showed that 73 (73%) had SDB. The BQ sensitivity and specificity was 0.68 and 0.34, respectively, with a positive predictive value of 0.68 and a negative predictive value of 0.50. Positive and negative likelihood ratios were 1.27 and 0.68, respectively, and the BQ overall diagnostic accuracy was 63%. Using different apnea-hypopnea index cutoff values did not meaningfully alter these results. Conclusion: The BQ performed with modest sensitivity, but the specificity was poor, suggesting that the BQ is not ideal in identifying SDB in patients with a recent MI. PMID:21596794
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valencia, Antoni; Prous, Josep; Mora, Oscar
As indicated in ICH M7 draft guidance, in silico predictive tools including statistically-based QSARs and expert analysis may be used as a computational assessment for bacterial mutagenicity for the qualification of impurities in pharmaceuticals. To address this need, we developed and validated a QSAR model to predict Salmonella t. mutagenicity (Ames assay outcome) of pharmaceutical impurities using Prous Institute's Symmetry℠, a new in silico solution for drug discovery and toxicity screening, and the Mold2 molecular descriptor package (FDA/NCTR). Data was sourced from public benchmark databases with known Ames assay mutagenicity outcomes for 7300 chemicals (57% mutagens). Of these data, 90%more » was used to train the model and the remaining 10% was set aside as a holdout set for validation. The model's applicability to drug impurities was tested using a FDA/CDER database of 951 structures, of which 94% were found within the model's applicability domain. The predictive performance of the model is acceptable for supporting regulatory decision-making with 84 ± 1% sensitivity, 81 ± 1% specificity, 83 ± 1% concordance and 79 ± 1% negative predictivity based on internal cross-validation, while the holdout dataset yielded 83% sensitivity, 77% specificity, 80% concordance and 78% negative predictivity. Given the importance of having confidence in negative predictions, an additional external validation of the model was also carried out, using marketed drugs known to be Ames-negative, and obtained 98% coverage and 81% specificity. Additionally, Ames mutagenicity data from FDA/CFSAN was used to create another data set of 1535 chemicals for external validation of the model, yielding 98% coverage, 73% sensitivity, 86% specificity, 81% concordance and 84% negative predictivity. - Highlights: • A new in silico QSAR model to predict Ames mutagenicity is described. • The model is extensively validated with chemicals from the FDA and the public domain. • Validation tests show desirable high sensitivity and high negative predictivity. • The model predicted 14 reportedly difficult to predict drug impurities with accuracy. • The model is suitable to support risk evaluation of potentially mutagenic compounds.« less
Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin
2017-01-01
To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.
Jue, Joshua S; Barboza, Marcelo Panizzutti; Prakash, Nachiketh S; Venkatramani, Vivek; Sinha, Varsha R; Pavan, Nicola; Nahar, Bruno; Kanabur, Pratik; Ahdoot, Michael; Dong, Yan; Satyanarayana, Ramgopal; Parekh, Dipen J; Punnen, Sanoj
2017-07-01
To compare the predictive accuracy of prostate-specific antigen (PSA) density vs PSA across different PSA ranges and by prior biopsy status in a prospective cohort undergoing prostate biopsy. Men from a prospective trial underwent an extended template biopsy to evaluate for prostate cancer at 26 sites throughout the United States. The area under the receiver operating curve assessed the predictive accuracy of PSA density vs PSA across 3 PSA ranges (<4 ng/mL, 4-10 ng/mL, >10 ng/mL). We also investigated the effect of varying the PSA density cutoffs on the detection of cancer and assessed the performance of PSA density vs PSA in men with or without a prior negative biopsy. Among 1290 patients, 585 (45%) and 284 (22%) men had prostate cancer and significant prostate cancer, respectively. PSA density performed better than PSA in detecting any prostate cancer within a PSA of 4-10 ng/mL (area under the receiver operating characteristic curve [AUC]: 0.70 vs 0.53, P < .0001) and within a PSA >10 mg/mL (AUC: 0.84 vs 0.65, P < .0001). PSA density was significantly more predictive than PSA in detecting any prostate cancer in men without (AUC: 0.73 vs 0.67, P < .0001) and with (AUC: 0.69 vs 0.55, P < .0001) a previous biopsy; however, the incremental difference in AUC was higher among men with a previous negative biopsy. Similar inferences were seen for significant cancer across all analyses. As PSA increases, PSA density becomes a better marker for predicting prostate cancer compared with PSA alone. Additionally, PSA density performed better than PSA in men with a prior negative biopsy. Copyright © 2017 Elsevier Inc. All rights reserved.
Xiao, Guangqin; Zhu, Feng; Wang, Min; Zhang, Hang; Ye, Dawei; Yang, Jiayin; Jiang, Li; Liu, Chang; Yan, Lunan; Qin, Renyi
2016-10-01
Aspartate aminotransferase to platelet ratio index (APRI) and the fibrosis index based on four factors (FIB-4) are the two most focused non-invasive models to assess liver fibrosis. We aimed to examine the validity of these two models for predicting hepatitis B virus (HBV)-related liver fibrosis accompanied with hepatocellular carcinoma (HCC). We enrolled HBV-infected patients with liver cancer who had received hepatectomy. The accuracy of APRI and FIB-4 for diagnosing liver fibrosis was assessed based on their sensitivity, specificity, diagnostic efficiency, positive predictive value (PPV), negative predictive value (NPV), kappa (κ) value and area under the receiver-operating characteristic curve (AUC). Finally 2176 patients were included, with 1682 retrospective subjects and 494 prospective subjects. APRI (rs=0.310) and FIB-4 (rs=0.278) were positively correlated with liver fibrosis. And χ(2) analysis demonstrated that APRI and FIB-4 values correlated with different levels of liver fibrosis with all P values less than 0.01. The AUC values for APRI and FIB-4 were 0.685 and 0.626 (P=0.73) for predicting significant fibrosis, 0.681 and 0.648 (P=0.81) for differentiation of advanced fibrosis and 0.676 and 0.652 (P=0.77) for diagnosing cirrhosis. APRI and FIB-4 correlate with liver fibrosis. However these two models have low accuracy for predicting HBV-related liver fibrosis in HCC patients. Copyright © 2016. Published by Elsevier Ltd.
Application and analysis of debris-flow early warning system in Wenchuan earthquake-affected area
NASA Astrophysics Data System (ADS)
Liu, D. L.; Zhang, S. J.; Yang, H. J.; Zhao, L. Q.; Jiang, Y. H.; Tang, D.; Leng, X. P.
2016-02-01
The activities of debris flow (DF) in the Wenchuan earthquake-affected area significantly increased after the earthquake on 12 May 2008. The safety of the lives and property of local people is threatened by DFs. A physics-based early warning system (EWS) for DF forecasting was developed and applied in this earthquake area. This paper introduces an application of the system in the Wenchuan earthquake-affected area and analyzes the prediction results via a comparison to the DF events triggered by the strong rainfall events reported by the local government. The prediction accuracy and efficiency was first compared with a contribution-factor-based system currently used by the weather bureau of Sichuan province. The storm on 17 August 2012 was used as a case study for this comparison. The comparison shows that the false negative rate and false positive rate of the new system is, respectively, 19 and 21 % lower than the system based on the contribution factors. Consequently, the prediction accuracy is obviously higher than the system based on the contribution factors with a higher operational efficiency. On the invitation of the weather bureau of Sichuan province, the authors upgraded their prediction system of DF by using this new system before the monsoon of Wenchuan earthquake-affected area in 2013. Two prediction cases on 9 July 2013 and 10 July 2014 were chosen to further demonstrate that the new EWS has high stability, efficiency, and prediction accuracy.
LADABAUM, URI; FIORITTO, ANN; MITANI, AYA; DESAI, MANISHA; KIM, JANE P.; REX, DOUGLAS K.; IMPERIALE, THOMAS; GUNARATNAM, NARESH
2017-01-01
BACKGROUND & AIMS Accurate optical analysis of colorectal polyps (optical biopsy) could prevent unnecessary polypectomies or allow a “resect and discard” strategy with surveillance intervals determined based on the results of the optical biopsy; this could be less expensive than histopathologic analysis of polyps. We prospectively evaluated real-time optical biopsy analysis of polyps with narrow band imaging (NBI) by community-based gastroenterologists. METHODS We first analyzed a computerized module to train gastroenterologists (N = 13) in optical biopsy skills using photographs of polyps. Then we evaluated a practice-based learning program for these gastroenterologists (n = 12) that included real-time optical analysis of polyps in vivo, comparison of optical biopsy predictions to histopathologic analysis, and ongoing feedback on performance. RESULTS Twelve of 13 subjects identified adenomas with >90% accuracy at the end of the computer study, and 3 of 12 subjects did so with accuracy ≥90% in the in vivo study. Learning curves showed considerable variation among batches of polyps. For diminutive rectosigmoid polyps assessed with high confidence at the end of the study, adenomas were identified with mean (95% confidence interval [CI]) accuracy, sensitivity, specificity, and negative predictive values of 81% (73%–89%), 85% (74%–96%), 78% (66%–92%), and 91% (86%–97%), respectively. The adjusted odds ratio for high confidence as a predictor of accuracy was 1.8 (95% CI, 1.3–2.5). The agreement between surveillance recommendations informed by high-confidence NBI analysis of diminutive polyps and results from histopathologic analysis of all polyps was 80% (95% CI, 77%–82%). CONCLUSIONS In an evaluation of real-time optical biopsy analysis of polyps with NBI, only 25% of gastroenterologists assessed polyps with ≥90% accuracy. The negative predictive value for identification of adenomas, but not the surveillance interval agreement, met the American Society for Gastrointestinal Endoscopy–recommended thresholds for optical biopsy. Better results in community practice must be achieved before NBI-based optical biopsy methods can be used routinely to evaluate polyps; ClinicalTrials.gov number, NCT01638091. PMID:23041328
The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas.
Sabzghabaei, Anita; Shojaee, Majid; Safari, Saeed; Hatamabadi, Hamid Reza; Shirvani, Reza
2016-01-01
In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT) scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4), 58.5% (95% CI: 51.2-65.5), 56% (95% CI: 48.5-63.3), 79.6% (95% CI: 71.8-85.7), 1.27% (95% CI: 1.30-1.57), and 0.25% (95% CI: 0.18-0.36), respectively. The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.
Zhang, Yaogong; Liu, Jiahui; Liu, Xiaohu; Hong, Yuxiang; Fan, Xin; Huang, Yalou; Wang, Yuan; Xie, Maoqiang
2018-04-24
Gene-phenotype association prediction can be applied to reveal the inherited basis of human diseases and facilitate drug development. Gene-phenotype associations are related to complex biological processes and influenced by various factors, such as relationship between phenotypes and that among genes. While due to sparseness of curated gene-phenotype associations and lack of integrated analysis of the joint effect of multiple factors, existing applications are limited to prediction accuracy and potential gene-phenotype association detection. In this paper, we propose a novel method by exploiting weighted graph constraint learned from hierarchical structures of phenotype data and group prior information among genes by inheriting advantages of Non-negative Matrix Factorization (NMF), called Weighted Graph Constraint and Group Centric Non-negative Matrix Factorization (GC[Formula: see text]NMF). Specifically, first we introduce the depth of parent-child relationships between two adjacent phenotypes in hierarchical phenotypic data as weighted graph constraint for a better phenotype understanding. Second, we utilize intra-group correlation among genes in a gene group as group constraint for gene understanding. Such information provides us with the intuition that genes in a group probably result in similar phenotypes. The model not only allows us to achieve a high-grade prediction performance, but also helps us to learn interpretable representation of genes and phenotypes simultaneously to facilitate future biological analysis. Experimental results on biological gene-phenotype association datasets of mouse and human demonstrate that GC[Formula: see text]NMF can obtain superior prediction accuracy and good understandability for biological explanation over other state-of-the-arts methods.
Diagnostic accuracy of patch test in children with food allergy.
Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo
2015-08-01
The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G
2014-01-01
To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.
On-line analysis of algae in water by discrete three-dimensional fluorescence spectroscopy.
Zhao, Nanjing; Zhang, Xiaoling; Yin, Gaofang; Yang, Ruifang; Hu, Li; Chen, Shuang; Liu, Jianguo; Liu, Wenqing
2018-03-19
In view of the problem of the on-line measurement of algae classification, a method of algae classification and concentration determination based on the discrete three-dimensional fluorescence spectra was studied in this work. The discrete three-dimensional fluorescence spectra of twelve common species of algae belonging to five categories were analyzed, the discrete three-dimensional standard spectra of five categories were built, and the recognition, classification and concentration prediction of algae categories were realized by the discrete three-dimensional fluorescence spectra coupled with non-negative weighted least squares linear regression analysis. The results show that similarities between discrete three-dimensional standard spectra of different categories were reduced and the accuracies of recognition, classification and concentration prediction of the algae categories were significantly improved. By comparing with that of the chlorophyll a fluorescence excitation spectra method, the recognition accuracy rate in pure samples by discrete three-dimensional fluorescence spectra is improved 1.38%, and the recovery rate and classification accuracy in pure diatom samples 34.1% and 46.8%, respectively; the recognition accuracy rate of mixed samples by discrete-three dimensional fluorescence spectra is enhanced by 26.1%, the recovery rate of mixed samples with Chlorophyta 37.8%, and the classification accuracy of mixed samples with diatoms 54.6%.
Dyrba, Martin; Barkhof, Frederik; Fellgiebel, Andreas; Filippi, Massimo; Hausner, Lucrezia; Hauenstein, Karlheinz; Kirste, Thomas; Teipel, Stefan J
2015-01-01
Alzheimer's disease (AD) patients show early changes in white matter (WM) structural integrity. We studied the use of diffusion tensor imaging (DTI) in assessing WM alterations in the predementia stage of mild cognitive impairment (MCI). We applied a Support Vector Machine (SVM) classifier to DTI and volumetric magnetic resonance imaging data from 35 amyloid-β42 negative MCI subjects (MCI-Aβ42-), 35 positive MCI subjects (MCI-Aβ42+), and 25 healthy controls (HC) retrieved from the European DTI Study on Dementia. The SVM was applied to DTI-derived fractional anisotropy, mean diffusivity (MD), and mode of anisotropy (MO) maps. For comparison, we studied classification based on gray matter (GM) and WM volume. We obtained accuracies of up to 68% for MO and 63% for GM volume when it came to distinguishing between MCI-Aβ42- and MCI-Aβ42+. When it came to separating MCI-Aβ42+ from HC we achieved an accuracy of up to 77% for MD and a significantly lower accuracy of 68% for GM volume. The accuracy of multimodal classification was not higher than the accuracy of the best single modality. Our results suggest that DTI data provide better prediction accuracy than GM volume in predementia AD. Copyright © 2015 by the American Society of Neuroimaging.
Prediction of early and late preeclampsia by flow-mediated dilation of the brachial artery*
Brandão, Augusto Henriques Fulgêncio; Evangelista, Aline Aarão; Martins, Raphaela Menin Franco; Leite, Henrique Vítor; Cabral, Antônio Carlos Vieira
2014-01-01
Objective To assess the accuracy in the prediction of both early and late preeclampsia by flow-mediated dilation of the brachial artery (FMD), a biophysical marker for endothelial dysfunction. Materials and Methods A total of 91 patients, considered at high risk for development of preeclampsia were submitted to brachial artery FMD between 24 and 28 weeks of gestation. Results Nineteen out of the selected patients developed preeclampsia, 8 in its early form and 11 in the late form. With a cut-off value of 6.5%, the FMD sensitivity for early preeclampsia prediction was 75.0%, with specificity of 73.3%, positive predictive value (PPV) of 32.4% and negative predictive value (NPV) of 91.9%. For the prediction of late preeclampsia, sensitivity = 83.3%, specificity = 73.2%, PPV = 34.4% and NPV = 96.2% were observed. And for the prediction of all associated forms of preeclampsia, sensitivity = 84.2%, specificity = 73.6%, PPV = 45.7% and NPV = 94.6% were observed. Conclusion FMD of the brachial artery is a test with good accuracy in the prediction of both early and late preeclampsia, which may represent a positive impact on the follow-up of pregnant women at high risk for developing this syndrome. PMID:25741086
Alphs, Larry; Morlock, Robert; Coon, Cheryl; Cazorla, Pilar; Szegedi, Armin; Panagides, John
2011-06-01
The 16-item Negative Symptom Assessment (NSA-16) scale is a validated tool for evaluating negative symptoms of schizophrenia. The psychometric properties and predictive power of a four-item version (NSA-4) were compared with the NSA-16. Baseline data from 561 patients with predominant negative symptoms of schizophrenia who participated in two identically designed clinical trials were evaluated. Ordered logistic regression analysis of ratings using NSA-4 and NSA-16 were compared with ratings using several other standard tools to determine predictive validity and construct validity. Internal consistency and test--retest reliability were also analyzed. NSA-16 and NSA-4 scores were both predictive of scores on the NSA global rating (odds ratio = 0.83-0.86) and the Clinical Global Impressions--Severity scale (odds ratio = 0.91-0.93). NSA-16 and NSA-4 showed high correlation with each other (Pearson r = 0.85), similar high correlation with other measures of negative symptoms (demonstrating convergent validity), and lesser correlations with measures of other forms of psychopathology (demonstrating divergent validity). NSA-16 and NSA-4 both showed acceptable internal consistency (Cronbach α, 0.85 and 0.64, respectively) and test--retest reliability (intraclass correlation coefficient, 0.87 and 0.82). This study demonstrates that NSA-4 offers accuracy comparable to the NSA-16 in rating negative symptoms in patients with schizophrenia. Copyright © 2011 John Wiley & Sons, Ltd.
Makuuchi, Ryoko; Jere, Sandy; Hasejima, Nobuchika; Chigeda, Thoms; Gausi, January
2017-05-02
Faint test bands of Paracheck Pf.® are interpreted as malaria positive according to world health organization (WHO) guideline. However if there are conspicuous number of faint test bands, a performance of Paracheck Pf.® could be influenced depending on whether interpreting faint test bands as malaria positive or negative. Finding out the frequency and accurate interpretation of faint test bands are important to prevent the overdiagnosis and drug resistance. A cross-sectional, descriptive study was conducted to find out the frequency of faint test bands and evaluate the performance of Paracheck Pf.® by sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosis of Paracheck Pf.® using microscopy as the gold standard. 388 suspected patients with malaria in Malawi were recruited in this study. Malaria rapid diagnostic tests (RDTs) and microscopy were used and patients' information which includes age, sex, body temperature and signs or symptoms of malaria were recorded. Among all patients involved in the study, 29.1% (113/388) were found malaria positive by RDT. Overall 5.4% (21/388) of all Paracheck Pf.® tests resulted in a "faint test band" and 85.7% (18/21) corresponded with malaria negative by microscopy. Faint test bands which corresponded with malaria positive by microscopy were lower parasite density and there are no patients who showed definitive symptom of malaria, such as fever. When Paracheck Pf.® "faint test bands" were classified as positive, accuracy of diagnosis was 76.5% (95% CI 72%-80.7%) as compared to 80.4% (95% CI 76.1%-84.2%) when Paracheck Pf.® "faint test bands" were classified as negative. This study shows that frequency of faint test bands is 5.4% in all malaria RDTs. The accuracy of diagnosis was improved when faint test bands were interpreted as malaria negative. However information and data obtained in this study may not be enough and more intensive research including a frequency and property of faint test bands is needed for significant interpretation of faint test bands.
Hwang, Yoo Na; Lee, Ju Hwan; Kim, Ga Young; Jiang, Yuan Yuan; Kim, Sung Min
2015-01-01
This paper focuses on the improvement of the diagnostic accuracy of focal liver lesions by quantifying the key features of cysts, hemangiomas, and malignant lesions on ultrasound images. The focal liver lesions were divided into 29 cysts, 37 hemangiomas, and 33 malignancies. A total of 42 hybrid textural features that composed of 5 first order statistics, 18 gray level co-occurrence matrices, 18 Law's, and echogenicity were extracted. A total of 29 key features that were selected by principal component analysis were used as a set of inputs for a feed-forward neural network. For each lesion, the performance of the diagnosis was evaluated by using the positive predictive value, negative predictive value, sensitivity, specificity, and accuracy. The results of the experiment indicate that the proposed method exhibits great performance, a high diagnosis accuracy of over 96% among all focal liver lesion groups (cyst vs. hemangioma, cyst vs. malignant, and hemangioma vs. malignant) on ultrasound images. The accuracy was slightly increased when echogenicity was included in the optimal feature set. These results indicate that it is possible for the proposed method to be applied clinically.
Starry sky sign: A prevalent sonographic finding in mediastinal tuberculous lymph nodes.
Alici, Ibrahim Onur; Demirci, Nilg N Yilmaz; Yilmaz, Aydin; Karakaya, Jale; Erdogan, Yurdanur
2015-01-01
We report a prevalent finding in tuberculous lymphadenitis (TL): Starry sky sign, hyperechoic foci without acoustic shadows over a hypoechoic background. We retrospectively searched the database for a possible relationship of starry sky sign with a specific diagnosis and also the prevalence and accuracy of the finding. Starry sky sign was found in 16 of 31 tuberculous lymph nodes, while none of other lymph nodes (1,015 lymph nodes) exhibited this finding; giving a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 51.6%, 100%, 100%, 98.5%, and 98.5%, respectively. Bacteriologic and histologic findings are gold standard in the diagnosis of tuberculosis, but this finding may guide the bronchoscopist in choosing the more pathologic node within a station and increase the diagnostic yield as it may relate to actively dividing mycobacteria.
NASA Astrophysics Data System (ADS)
Rezeki, S.; Pasaribu, A. P.
2018-03-01
Indonesia is the country where malaria is still the most common population problem. The high rate of mortality and morbidity occurred due to delays in diagnosis whichis strongly influenced by the availability of diagnostic tools and personnel with required laboratory skill. This diagnostic study aims to compare the accuracy of a Rapid Diagnostic Test (RDT) without skill requirement, to agold standard microscopic method for malaria diagnosis. The study was conducted in Subdistrict Lima Puluh North Sumatera Province from December 2015 to January 2016. The subject was taken cross-sectionally from a population with characteristics typically found in malaria patients in Subdistrict Lima Puluh. The result showed a sensitivity of 100% and a specificity of 72.4% with a positive predictive value of 89.9% and a negative predictive value of 100%; the negative likelihood ratio is 0 and the positive likelihood ratio of 27.6 for Parascreen. This research indicates that Parascreen had a high sensitivity and specificity and may be consideredas an alternative for the diagnosis of malaria in Subdistrict Lima Puluh North Sumatera Province especially in areas where no skilled microscopist is available.
Nazir, Mudasir; Wani, Wasim Ahmad; Malik, Muzaffar Ahmad; Mir, Mohd Rafiq; Ashraf, Younis; Kawoosa, Khalid; Ali, Syed Wajid
To assess the performance of cerebrospinal fluid (CSF) lactate as a biomarker to differentiate bacterial meningitis from viral meningitis in children, and to define an optimal CSF lactate concentration that can be called significant for the differentiation. Children with clinical findings compatible with meningitis were studied. CSF lactate and other conventional CSF parameters were recorded. At a cut-off value of 3mmol/L, CSF lactate had a sensitivity of 0.90, specificity of 1.0, positive predictive value of 1.0, and negative predictive value of 0.963, with an accuracy of 0.972. The positive and negative likelihood ratios were 23.6 and 0.1, respectively. When comparing between bacterial and viral meningitis, the area under the curve for CSF lactate was 0.979. The authors concluded that CSF lactate has high sensitivity and specificity in differentiating bacterial from viral meningitis. While at a cut-off value of 3mmol/L, CSF lactate has high diagnostic accuracy for bacterial meningitis, mean levels in viral meningitis remain essentially below 2mmol/L. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access.
Wasinrat, Jitladda; Siriapisith, Thanongchai; Thamtorawat, Somrach; Tongdee, Trongtum
2011-01-01
To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant (<50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction.
Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube
Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei
2018-01-01
Abstract This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs). A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis. When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P < .01). When right DLTs (RDLTs) were used, the accuracy of ultrasound (89.1% [76.4%, 96.4%]) was higher than the accuracy of auscultation (67.4% [52.0%, 80.5%]) (P < .01). When LDLTs were used in the lateral position, the accuracy of ultrasound (75.4% [62.2%, 85.9%]) was higher than the accuracy of auscultation (54.4% [40.7%, 67.6%]) (P < .05). When RDLT were used, the accuracy of ultrasound (73.9% [58.9%, 85.7%]) was higher than the accuracy of auscultation (47.8% [32.9%, 63.1%]) (P < .05). Assessment via point-of-care ultrasound is superior to auscultation in determining the position of DLTs. PMID:29595696
Point-of-care ultrasound versus auscultation in determining the position of double-lumen tube.
Hu, Wei-Cai; Xu, Lei; Zhang, Quan; Wei, Li; Zhang, Wei
2018-03-01
This study was designed to assess the accuracy of point-of-care ultrasound in determining the position of double-lumen tubes (DLTs).A total of 103 patients who required DLT intubation were enrolled into the study. After DLTs were tracheal intubated in the supine position, an auscultation researcher and ultrasound researcher were sequentially invited in the operating room to conduct their evaluation of the DLT. After the end of their evaluation, fiberscope researchers (FRs) were invited in the operating room to evaluate the position of DLT using a fiberscope. After the patients were changed to the lateral position, the same evaluation process was repeated. These 3 researchers were blind to each other when they made their conclusions. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained by statistical analysis.When left DLTs (LDLTs) were used, the accuracy of ultrasound (84.2% [72.1%, 92.5%]) was higher than the accuracy of auscultation (59.7% [45.8%, 72.4%]) (P < .01). When right DLTs (RDLTs) were used, the accuracy of ultrasound (89.1% [76.4%, 96.4%]) was higher than the accuracy of auscultation (67.4% [52.0%, 80.5%]) (P < .01). When LDLTs were used in the lateral position, the accuracy of ultrasound (75.4% [62.2%, 85.9%]) was higher than the accuracy of auscultation (54.4% [40.7%, 67.6%]) (P < .05). When RDLT were used, the accuracy of ultrasound (73.9% [58.9%, 85.7%]) was higher than the accuracy of auscultation (47.8% [32.9%, 63.1%]) (P < .05).Assessment via point-of-care ultrasound is superior to auscultation in determining the position of DLTs.
Strumwasser, Aaron; Chong, Vincent; Chu, Eveline; Victorino, Gregory P
2016-09-01
The precise role of thoracic CT in penetrating chest trauma remains to be defined. We hypothesized that thoracic CT effectively screens hemodynamically normal patients with penetrating thoracic trauma to surgery vs. expectant management (NOM). A ten-year review of all penetrating torso cases was retrospectively analyzed from our urban University-based trauma center. We included hemodynamically normal patients (systolic blood pressure ≥90) with penetrating chest injuries that underwent screening thoracic CT. Hemodynamically unstable patients and diaphragmatic injuries were excluded. The sensitivity, specificity, positive predictive value and negative predictive value were calculated. A total of 212 patients (mean injury severity score=24, Abbreviated Injury Score for Chest=3.9) met inclusion criteria. Of these, 84.3% underwent NOM, 9.1% necessitated abdominal exploration, 6.6% underwent exploration for retained hemothorax/empyema, 6.6% underwent immediate thoracic exploration for significant injuries on chest CT, and 1.0% underwent delayed thoracic exploration for missed injuries. Thoracic CT had a sensitivity of 82%, specificity of 99%, positive predictive value of 90%, a negative predictive value of 99%, and an accuracy of 99% in predicting surgery vs. NOM. Thoracic CT has a negative predictive value of 99% in triaging hemodynamically normal patients with penetrating chest trauma. Screening thoracic CT successfully excludes surgery in patients with non-significant radiologic findings. Copyright © 2016. Published by Elsevier Ltd.
Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S
2015-01-01
Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622
Pailing, Patricia E; Segalowitz, Sidney J
2004-01-01
This study examines changes in the error-related negativity (ERN/Ne) related to motivational incentives and personality traits. ERPs were gathered while adults completed a four-choice letter task during four motivational conditions. Monetary incentives for finger and hand accuracy were altered across motivation conditions to either be equal or favor one type of accuracy over the other in a 3:1 ratio. Larger ERN/Ne amplitudes were predicted with increased incentives, with personality moderating this effect. Results were as expected: Individuals higher on conscientiousness displayed smaller motivation-related changes in the ERN/Ne. Similarly, those low on neuroticism had smaller effects, with the effect of Conscientiousness absent after accounting for Neuroticism. These results emphasize an emotional/evaluative function for the ERN/Ne, and suggest that the ability to selectively invest in error monitoring is moderated by underlying personality.
Matsuda, Eriko; Fukuhara, Takahiro; Donishi, Ryohei; Kawamoto, Katsuyuki; Hirooka, Yasuaki; Takeuchi, Hiromi
2018-01-01
Background Ultrasonographic homogeneity is an important differential finding between Warthin tumor and pleomorphic adenoma, two types of benign parotid gland tumors, with the former likely to be heterogeneous and the latter homogeneous. However, differences in the performance of ultrasound machines or the homogeneity cut-off level affect the judgment of ultrasonographic homogeneity. Therefore, in this study, we adopted a novel system for classifying the composition of tumors via ultrasonography, using anechoic area as a substitute for differences in homogeneity to differentiate between Warthin tumors and pleomorphic adenomas. Methods We evaluated 68 tumors that were histopathologically diagnosed as Warthin tumor or pleomorphic adenoma between July 2009 and November 2015. Ultrasonographic images of the tumors were evaluated on the basis of key differentiating features, including features on B-mode imaging and color Doppler imaging. Additionally, the tumors were classified into four groups based on anechoic area, and findings were compared between Warthin tumors and pleomorphic adenomas. Results While 38 of the tumors were pleomorphic adenomas, 30 were Warthin tumors. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for detection of Warthin tumors using our novel classification system were 73.3%, 76.3%, 71.0%, 78.4% and 75.0%, respectively. Compared to pleomorphic adenomas, Warthin tumors showed large or sponge-like anechoic areas, rich vascularization and an oval shape even at large tumor sizes, and the difference was significant. On defining Warthin tumor as a tumor demonstrating two or more of the findings noted above, the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for its detection were 73.3%, 84.2%, 78.6%, 80.0% and 79.4%, respectively. Conclusion Our novel classification system based on anechoic area patterns demonstrated by the tumors had high sensitivity, specificity and diagnostic accuracy for differentiating Warthin tumors from pleomorphic adenomas. PMID:29434491
Matsuda, Eriko; Fukuhara, Takahiro; Donishi, Ryohei; Kawamoto, Katsuyuki; Hirooka, Yasuaki; Takeuchi, Hiromi
2017-12-01
Ultrasonographic homogeneity is an important differential finding between Warthin tumor and pleomorphic adenoma, two types of benign parotid gland tumors, with the former likely to be heterogeneous and the latter homogeneous. However, differences in the performance of ultrasound machines or the homogeneity cut-off level affect the judgment of ultrasonographic homogeneity. Therefore, in this study, we adopted a novel system for classifying the composition of tumors via ultrasonography, using anechoic area as a substitute for differences in homogeneity to differentiate between Warthin tumors and pleomorphic adenomas. We evaluated 68 tumors that were histopathologically diagnosed as Warthin tumor or pleomorphic adenoma between July 2009 and November 2015. Ultrasonographic images of the tumors were evaluated on the basis of key differentiating features, including features on B-mode imaging and color Doppler imaging. Additionally, the tumors were classified into four groups based on anechoic area, and findings were compared between Warthin tumors and pleomorphic adenomas. While 38 of the tumors were pleomorphic adenomas, 30 were Warthin tumors. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for detection of Warthin tumors using our novel classification system were 73.3%, 76.3%, 71.0%, 78.4% and 75.0%, respectively. Compared to pleomorphic adenomas, Warthin tumors showed large or sponge-like anechoic areas, rich vascularization and an oval shape even at large tumor sizes, and the difference was significant. On defining Warthin tumor as a tumor demonstrating two or more of the findings noted above, the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for its detection were 73.3%, 84.2%, 78.6%, 80.0% and 79.4%, respectively. Our novel classification system based on anechoic area patterns demonstrated by the tumors had high sensitivity, specificity and diagnostic accuracy for differentiating Warthin tumors from pleomorphic adenomas.
Moore, William; Ripton-Snyder, Jennifer; Wu, George; Hendler, Craig
2011-06-01
The objective of this research was to determine the sensitivity and specificity of a commercially available computer-aided detection (CAD) system for detection of lung nodule on posterior-anterior (PA) chest radiograph in a varied patient population who are referred to computed tomographic angiogram (CTA) of the chest as a reference standard. Patients who had a PA chest radiograph with concomitant CTA of the chest were included in this retrospective study. The PA chest radiograph was analyzed by a CAD device, and results were recorded. A qualitative assessment of the CAD results was performed using a 5-point Likert scale. The CTA was then reviewed to determine if there were correlative nodules. The presence of a correlative nodule between 0.5 cm and 1.5 cm was considered a positive result. The baseline sensitivity of the system was determined to be 0.707 (95% CI = 0.52-0.86), with a specificity of 0.50 (95% CI = 0.38-0.76). Positive predictive value was 0.30 (95% CI = 0.24-0.49), with a negative predictive value of 0.858 (95% CI = 0.82-0.95), and accuracy of 0.555 (95% CI = 0.40-0.66). When excluding nodules that were qualitatively determined by a thoracic radiologist to be false positives, the specificity was 0.781 (95% CI = 0.764-0.839), the positive predictive value was 0.564 (95% CI = 0.491-0.654), the negative predictive value was 0.829 (95% CI = 0.819-0.878), and the accuracy was 0.737 (95% CI = 0.721-0.801). The use of CAD for lung nodule detection on chest radiograph, when used in conjunction with an experienced radiologist, has a very good sensitivity, specificity, and accuracy.
Materials 88: Materials and Engineering Design Held in London, England, on 9-13 May 1988
1988-01-01
process changing from a temperatures in the rings would have favoured the polishing mechanism for the lapped specimens, to microplastic abrasion and...UE - ultimate shear strength of epoxy adhesive Solid line EE - elastic limit of epoxy adhesive. Sea . UE E4QGE E 7.3S 27.5- E 5 1. . 5 1.- Ps. 7. 7 P zs...is well predicted. The accuracy of the predicted contribute negatively to kA due to the presence of the abpoitc B.E. and initial microplasticity
Arbab-Zadeh, Armin; Miller, Julie M; Rochitte, Carlos E; Dewey, Marc; Niinuma, Hiroyuki; Gottlieb, Ilan; Paul, Narinder; Clouse, Melvin E.; Shapiro, Edward P.; Hoe, John; Lardo, Albert C.; Bush, David E.; de Roos, Albert; Cox, Christopher; Brinker, Jeffrey; Lima, Joăo A. C.
2012-01-01
Objectives Assess the impact of patient population characteristics on accuracy by CT angiography (CTA) to detect obstructive coronary artery disease (CAD). Background The ability of CTA to exclude obstructive CAD in patients of different pretest probabilities and in presence of coronary calcification remains uncertain. Methods For the CorE-64 study 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD defined as 50% or greater luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥ 600. Area under the receiver-operating-characteristics curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pretest probability of CAD. Results Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI] 0.90-0.95). AUC remained 0.93 (0.90-0.96) after excluding patients with known CAD but decreased to 0.81 (0.71-0.89) in patients with calcium score ≥ 600 (p=0.077). While AUC were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pretest probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score < or ≥ 100, respectively (p= 0.053). Conclusions Both pretest probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. CTA is less effective for this purpose in patients with calcium score ≥ 600 and in patients with a high pretest probability for obstructive CAD. PMID:22261160
Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests
Naseri, Mandana; Khayat, Akbar; Zamaheni, Sara; Shojaeian, Shiva
2017-01-01
Introduction: The purpose of this study was to assess the accuracy of sensibility tests by correlating it with histologic pulp condition. Methods and Materials: Assessment of clinical signs and symptoms were performed on 65 permanent teeth that were scheduled to be extracted for periodontal, prosthodontic or orthodontic reasons. The normal pulp and reversible pulpitis were considered as treatable tooth conditions while irreversible pulpitis and necrosis were considered as untreatable conditions. The teeth were then extracted and sectioned for histological analysis of dental pulp. Histologic status and classification corresponded to the treatable or untreatable pulp condition. Comparisons between histological treatable and untreatable pulp condition were performed with chi-square analysis for sensibility test responses. The positive predictive value (PPV), negative predictive value (NPV) and accuracy to detect untreatable from treatable pulp condition were calculated for each test. Results: A significant difference was detected in the normal and a sharp lingered response to heat and cold tests. There was significant difference in the negative response to EPT between histological groups. The kappa agreement coefficient between clinical and histological diagnosis of pulp condition was about 0.843 (P<0.001). The accuracy of cold and heat tests and EPT to detect treatable pulp or untreatable pulp states were 78, 74 and 62%, respectively. The sensibility tests diagnosed untreatable pulpitis with a higher probability (NPV=63%-67% -54%, PPV=83%-91% -95% for heat, cold and EPT, respectively). Conclusion: Sensibility test results were more likely to diagnose pulpal disease or untreatable pulp conditions. However, to increase the diagnostic accuracy patient history, clinical signs and symptoms and also radiographic findings in conjunction with sensibility tests must be used. The result of this small study demonstrated a good agreement between clinical and histological pulp diagnosis. PMID:28179918
Diagnostic accuracy assessment of cytopathological examination of feline sporotrichosis.
Jessica, N; Sonia, R L; Rodrigo, C; Isabella, D F; Tânia, M P; Jeferson, C; Anna, B F; Sandro, A
2015-11-01
Sporotrichosis is an implantation mycosis caused by pathogenic species of Sporothrix schenckii complex that affects humans and animals, especially cats. Its main forms of zoonotic transmission include scratching, biting and/or contact with the exudate from lesions of sick cats. In Brazil, epidemic involving humans, dogs and cats has occurred since 1998. The definitive diagnosis of sporotrichosis is obtained by the isolation of the fungus in culture; however, the result can take up to four weeks, which may delay the beginning of antifungal treatment in some cases. Cytopathological examination is often used in feline sporotrichosis diagnosis, but accuracy parameters have not been established yet. The aim of this study was to evaluate the accuracy and reliability of cytopathological examination in the diagnosis of feline sporotrichosis. The present study included 244 cats from the metropolitan region of Rio de Janeiro, mostly males in reproductive age with three or more lesions in non-adjacent anatomical places. To evaluate the inter-observer reliability, two different observers performed the microscopic examination of the slides blindly. Test sensitivity was 84.9%. The values of positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio and accuracy were 86.0, 24.4, 2.02, 0.26 and 82.8%, respectively. The reliability between the two observers was considered substantial. We conclude that the cytopathological examination is a sensitive, rapid and practical method to be used in feline sporotrichosis diagnosis in outbreaks of this mycosis. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Hiersch, Liran; Melamed, Nir; Aviram, Amir; Bardin, Ron; Yogev, Yariv; Ashwal, Eran
2016-12-01
To compare the accuracy and cutoff points for cervical length for predicting preterm delivery in women with threatened preterm labor between those with a closed cervix and cervical dilatation. We conducted a retrospective cohort study of women with singleton pregnancies with threatened preterm labor before 34 weeks. The accuracy of cervical length for predicting preterm delivery was compared between women with cervical dilatation (0.5-3 cm) and those with a closed cervix. The predictive accuracy of cervical length for spontaneous preterm delivery was analyzed with several outcome-specific thresholds. Overall, 1068 women with threatened preterm labor met the inclusion criteria; of them, 276 (25.8%) had cervical dilatation, and 792 (74.2%) had a closed cervix. The risk of preterm delivery before 37 weeks was significantly higher in the cervical dilatation group than the closed cervix group, as well as a shorter assessment-to-delivery interval of within 14 days (P = .001 and .004, respectively). On a multivariable analysis, cervical length was independently associated with the risk of preterm delivery in both groups. There was no significant difference between women with cervical dilatation and those with a closed cervix regarding the area under the receiver operating characteristic curves of cervical length for prediction of preterm delivery before 37 (0.674 versus 0.618; P = .18) and 34 (0.628 versus 0.640; P = .88) weeks and an assessment-to-delivery interval of 14 days (0.686 versus 0.660; P= .72). The negative predictive value of cervical length ranged from 77.4% to 95.7% depending on the different thresholds used. Cervical length was significantly associated with the risk of preterm delivery in women presenting with threatened preterm labor and cervical dilatation of less than 3 cm. However, the predictive accuracy of cervical length as a single measure was relatively limited. © 2016 by the American Institute of Ultrasound in Medicine.
Bhimarao; Bhat, Venkataramana; Gowda, Puttanna VN
2015-01-01
Background The high incidence of IUGR and its low recognition lead to increasing perinatal morbidity and mortality for which prediction of IUGR with timely management decisions is of paramount importance. Many studies have compared the efficacy of several gestational age independent parameters and found that TCD/AC is a better predictor of asymmetric IUGR. Aim To compare the accuracy of transcerebellar diameter/abdominal circumference with head circumference/abdominal circumference in predicting asymmetric intrauterine growth retardation after 20 weeks of gestation. Materials and Methods The prospective study was conducted over a period of one year on 50 clinically suspected IUGR pregnancies who were evaluated with 3.5 MHz frequency ultrasound scanner by a single sonologist. BPD, HC, AC and FL along with TCD were measured for assessing the sonological gestational age. Two morphometric ratios- TCD/AC and HC/AC were calculated. Estimated fetal weight was calculated for all these pregnancies and its percentile was determined. Statistical Methods The TCD/AC and HC/AC ratios were correlated with advancing gestational age to know if these were related to GA. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) for TCD/AC and HC/AC ratios in evaluating IUGR fetuses were calculated. Results In the present study, linear relation of TCD and HC in IUGR fetuses with gestation was noted. The sensitivity, specificity, PPV, NPV & DA were 88%, 93.5%, 77.1%, 96.3% & 92.4% respectively for TCD/AC ratio versus 84%, 92%, 72.4%, 95.8% & 90.4% respectively for HC/AC ratio in predicting IUGR. Conclusion Both ratios were gestational age independent and can be used in detecting IUGR with good diagnostic accuracy. However, TCD/AC ratio had a better diagnostic validity and accuracy compared to HC/AC ratio in predicting asymmetric IUGR. PMID:26557588
ShinyGPAS: interactive genomic prediction accuracy simulator based on deterministic formulas.
Morota, Gota
2017-12-20
Deterministic formulas for the accuracy of genomic predictions highlight the relationships among prediction accuracy and potential factors influencing prediction accuracy prior to performing computationally intensive cross-validation. Visualizing such deterministic formulas in an interactive manner may lead to a better understanding of how genetic factors control prediction accuracy. The software to simulate deterministic formulas for genomic prediction accuracy was implemented in R and encapsulated as a web-based Shiny application. Shiny genomic prediction accuracy simulator (ShinyGPAS) simulates various deterministic formulas and delivers dynamic scatter plots of prediction accuracy versus genetic factors impacting prediction accuracy, while requiring only mouse navigation in a web browser. ShinyGPAS is available at: https://chikudaisei.shinyapps.io/shinygpas/ . ShinyGPAS is a shiny-based interactive genomic prediction accuracy simulator using deterministic formulas. It can be used for interactively exploring potential factors that influence prediction accuracy in genome-enabled prediction, simulating achievable prediction accuracy prior to genotyping individuals, or supporting in-class teaching. ShinyGPAS is open source software and it is hosted online as a freely available web-based resource with an intuitive graphical user interface.
Scanning and War: Utility of FAST and CT in the Assessment of Battlefield Abdominal Trauma.
Smith, Iain M; Naumann, David N; Marsden, Max E R; Ballard, Mark; Bowley, Douglas M
2015-08-01
To determine utilization and accuracy of focused assessment with sonography for trauma (FAST) and computed tomography (CT) in a mature military trauma system to inform service provision for future conflicts. FAST and CT scans undertaken by attending radiologists contribute to surgical decision making for battlefield casualties at the Joint Force, Role 3 Medical Treatment Facility at Camp Bastion (R3), Afghanistan. Registry data for abdominally injured casualties treated at R3 from July to November 2012 were matched to radiological and surgical records to determine diagnostic accuracy for FAST and CT and their influence on casualty management. A total of 468 casualties met inclusion criteria, of whom 85.0% underwent FAST and 86.1% abdominal CT; 159 (34.0%) had abdominal injuries. For detection of intra-abdominal injury, FAST sensitivity (Sn) was 0.56, specificity (Sp) 0.98, positive predictive value (PPV) 0.87, negative predictive value (NPV) 0.90, and accuracy (Acc) 0.89. For CT, Sn was 0.99, Sp 0.99, PPV 0.96, NPV 1.00, and Acc 0.99. Forty-six solid organ injuries were identified in 38 patients by CT; 17 were managed nonoperatively. A further 61 patients avoided laparotomy after CT confirmed extra-abdominal wounds only. The negative laparotomy rate was 3.9%. FAST and CT contribute to triage, guide surgical management, and reduce nontherapeutic laparotomy. When imaging is available, these data challenge current doctrine about inadvisability of nonoperative management of abdominal injury after combat trauma.
Assessment of articular disc displacement of temporomandibular joint with ultrasound.
Razek, Ahmed Abdel Khalek Abdel; Al Mahdy Al Belasy, Fouad; Ahmed, Wael Mohamed Said; Haggag, Mai Ahmed
2015-06-01
To assess pattern of articular disc displacement in patients with internal derangement (ID) of temporomandibular joint (TMJ) with ultrasound. Prospective study was conducted upon 40 TMJ of 20 patients (3 male, 17 female with mean age of 26.1 years) with ID of TMJ. They underwent high-resolution ultrasound and MR imaging of TMJ. The MR images were used as the gold standard for calculating sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of ultrasound for diagnosis of anterior or sideway displacement of the disc. The anterior displaced disc was seen in 26 joints at MR and 22 joints at ultrasound. The diagnostic efficacy of ultrasound for anterior displacement has sensitivity of 79.3 %, specificity of 72.7 %, accuracy of 77.5 %, PPV of 88.5 %, NPV of 57.1 %, PLR of 2.9 and NLR of 0.34. The sideway displacement of disc was seen in four joints at MR and three joints at ultrasound. The diagnostic efficacy of ultrasound for sideway displacement has a sensitivity of 75 %, specificity of 63.6 %, accuracy of 66.7 %, PPV of 42.8, NPV of 87.5 %, PLR of 2.06, and NLR of 0.39. We concluded that ultrasound is a non-invasive imaging modality used for assessment of anterior and sideway displacement of the articular disc in patients with ID of TMJ.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cardan, R; Popple, R; Dobelbower, M
Purpose: To demonstrate the ability to quickly generate an accurate collision avoidance map using multiple stereotactic cameras during simulation. Methods: Three Kinect stereotactic cameras were placed in the CT simulation room and optically calibrated to the DICOM isocenter. Immediately before scanning, the patient was optically imaged to generate a 3D polygon mesh, which was used to calculate the collision avoidance area using our previously developed framework. The mesh was visually compared to the CT scan body contour to ensure accurate coordinate alignment. To test the accuracy of the collision calculation, the patient and machine were physically maneuvered in the treatmentmore » room to calculated collision boundaries. Results: The optical scan and collision calculation took 38.0 seconds and 2.5 seconds to complete respectively. The collision prediction accuracy was determined using a receiver operating curve (ROC) analysis, where the true positive, true negative, false positive and false negative values were 837, 821, 43, and 79 points respectively. The ROC accuracy was 93.1% over the sampled collision space. Conclusion: We have demonstrated a framework which is fast and accurate for predicting collision avoidance for treatment which can be determined during the normal simulation process. Because of the speed, the system could be used to add a layer of safety with a negligible impact on the normal patient simulation experience. This information could be used during treatment planning to explore the feasible geometries when optimizing plans. Research supported by Varian Medical Systems.« less
Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio
2018-01-31
To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.
Common polygenic variation enhances risk prediction for Alzheimer’s disease
Sims, Rebecca; Bannister, Christian; Harold, Denise; Vronskaya, Maria; Majounie, Elisa; Badarinarayan, Nandini; Morgan, Kevin; Passmore, Peter; Holmes, Clive; Powell, John; Brayne, Carol; Gill, Michael; Mead, Simon; Goate, Alison; Cruchaga, Carlos; Lambert, Jean-Charles; van Duijn, Cornelia; Maier, Wolfgang; Ramirez, Alfredo; Holmans, Peter; Jones, Lesley; Hardy, John; Seshadri, Sudha; Schellenberg, Gerard D.; Amouyel, Philippe
2015-01-01
The identification of subjects at high risk for Alzheimer’s disease is important for prognosis and early intervention. We investigated the polygenic architecture of Alzheimer’s disease and the accuracy of Alzheimer’s disease prediction models, including and excluding the polygenic component in the model. This study used genotype data from the powerful dataset comprising 17 008 cases and 37 154 controls obtained from the International Genomics of Alzheimer’s Project (IGAP). Polygenic score analysis tested whether the alleles identified to associate with disease in one sample set were significantly enriched in the cases relative to the controls in an independent sample. The disease prediction accuracy was investigated in a subset of the IGAP data, a sample of 3049 cases and 1554 controls (for whom APOE genotype data were available) by means of sensitivity, specificity, area under the receiver operating characteristic curve (AUC) and positive and negative predictive values. We observed significant evidence for a polygenic component enriched in Alzheimer’s disease (P = 4.9 × 10−26). This enrichment remained significant after APOE and other genome-wide associated regions were excluded (P = 3.4 × 10−19). The best prediction accuracy AUC = 78.2% (95% confidence interval 77–80%) was achieved by a logistic regression model with APOE, the polygenic score, sex and age as predictors. In conclusion, Alzheimer’s disease has a significant polygenic component, which has predictive utility for Alzheimer’s disease risk and could be a valuable research tool complementing experimental designs, including preventative clinical trials, stem cell selection and high/low risk clinical studies. In modelling a range of sample disease prevalences, we found that polygenic scores almost doubles case prediction from chance with increased prediction at polygenic extremes. PMID:26490334
Is Gaydar Affected by Attitudes Toward Homosexuality? Confidence, Labeling Bias, and Accuracy.
Brewer, Gayle; Lyons, Minna
2017-01-01
Previous research has largely ignored the relationship between sexual orientation judgement accuracy, confidence, and attitudes toward homosexuality. In an online study, participants (N = 269) judged the sexual orientation of homosexual and heterosexual targets presented via a series of facial photographs. Participants also indicated their confidence in each judgment and completed the Modern Homonegativity Scale (Morrison & Morrison, 2002). We found that (1) homosexual men and heterosexual women were more accurate when judging photographs of women as opposed to photographs of men, and (2) in heterosexual men, negative attitudes toward homosexual men predicted confidence and bias when rating men's photographs. Findings indicate that homosexual men and heterosexual women are similar in terms of accuracy in judging women's sexuality. Further, especially in men, homophobia is associated with cognitive biases in labeling other men but does not have a relationship with increased accuracy.
Noninvasive scoring system for significant inflammation related to chronic hepatitis B
NASA Astrophysics Data System (ADS)
Hong, Mei-Zhu; Ye, Linglong; Jin, Li-Xin; Ren, Yan-Dan; Yu, Xiao-Fang; Liu, Xiao-Bin; Zhang, Ru-Mian; Fang, Kuangnan; Pan, Jin-Shui
2017-03-01
Although a liver stiffness measurement-based model can precisely predict significant intrahepatic inflammation, transient elastography is not commonly available in a primary care center. Additionally, high body mass index and bilirubinemia have notable effects on the accuracy of transient elastography. The present study aimed to create a noninvasive scoring system for the prediction of intrahepatic inflammatory activity related to chronic hepatitis B, without the aid of transient elastography. A total of 396 patients with chronic hepatitis B were enrolled in the present study. Liver biopsies were performed, liver histology was scored using the Scheuer scoring system, and serum markers and liver function were investigated. Inflammatory activity scoring models were constructed for both hepatitis B envelope antigen (+) and hepatitis B envelope antigen (-) patients. The sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve were 86.00%, 84.80%, 62.32%, 95.39%, and 0.9219, respectively, in the hepatitis B envelope antigen (+) group and 91.89%, 89.86%, 70.83%, 97.64%, and 0.9691, respectively, in the hepatitis B envelope antigen (-) group. Significant inflammation related to chronic hepatitis B can be predicted with satisfactory accuracy by using our logistic regression-based scoring system.
Giovannini, Giada; Monti, Giulia; Tondelli, Manuela; Marudi, Andrea; Valzania, Franco; Leitinger, Markus; Trinka, Eugen; Meletti, Stefano
2017-03-01
Status epilepticus (SE) is a neurological emergency, characterized by high short-term morbidity and mortality. We evaluated and compared two scores that have been developed to evaluate status epilepticus prognosis: STESS (Status Epilepticus Severity Score) and EMSE (Epidemiology based Mortality score in Status Epilepticus). A prospective observational study was performed on consecutive patients with SE admitted between September 2013 and August 2015. Demographics, clinical variables, STESS-3 and -4, and EMSE-64 scores were calculated for each patient at baseline. SE drug response, 30-day mortality and morbidity were the outcomes measure. 162 episodes of SE were observed: 69% had a STESS ≥3; 34% had a STESS ≥4; 51% patients had an EMSE ≥64. The 30-days mortality was 31.5%: EMSE-64 showed greater negative predictive value (NPV) (97.5%), positive predictive value (PPV) (59.8%) and accuracy in the prediction of death than STESS-3 and STESS-4 (p<0.001). At 30 days, the clinical condition had deteriorated in 59% of the cases: EMSE-64 showed greater NPV (71.3%), PPV (87.8%) and accuracy than STESS-3 and STESS-4 (p<0.001) in the prediction of this outcome. In 23% of all cases, status epilepticus proved refractory to non-anaesthetic treatment. All three scales showed a high NPV (EMSE-64: 87.3%; STESS-4: 89.4%; STESS-3: 87.5%) but a low PPV (EMSE-64: 40.9%; STESS-4: 52.9%; STESS-3: 32%) for the prediction of refractoriness to first and second line drugs. This means that accuracy for the prediction of refractoriness was equally poor for all scales. EMSE-64 appears superior to STESS-3 and STESS-4 in the prediction of 30-days mortality and morbidity. All scales showed poor accuracy in the prediction of response to first and second line antiepileptic drugs. At present, there are no reliable scores capable of predicting treatment responsiveness. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Palacio, Montse; Bonet-Carne, Elisenda; Cobo, Teresa; Perez-Moreno, Alvaro; Sabrià, Joan; Richter, Jute; Kacerovsky, Marian; Jacobsson, Bo; García-Posada, Raúl A; Bugatto, Fernando; Santisteve, Ramon; Vives, Àngels; Parra-Cordero, Mauro; Hernandez-Andrade, Edgar; Bartha, José Luis; Carretero-Lucena, Pilar; Tan, Kai Lit; Cruz-Martínez, Rogelio; Burke, Minke; Vavilala, Suseela; Iruretagoyena, Igor; Delgado, Juan Luis; Schenone, Mauro; Vilanova, Josep; Botet, Francesc; Yeo, George S H; Hyett, Jon; Deprest, Jan; Romero, Roberto; Gratacos, Eduard
2017-08-01
Prediction of neonatal respiratory morbidity may be useful to plan delivery in complicated pregnancies. The limited predictive performance of the current diagnostic tests together with the risks of an invasive procedure restricts the use of fetal lung maturity assessment. The objective of the study was to evaluate the performance of quantitative ultrasound texture analysis of the fetal lung (quantusFLM) to predict neonatal respiratory morbidity in preterm and early-term (<39.0 weeks) deliveries. This was a prospective multicenter study conducted in 20 centers worldwide. Fetal lung ultrasound images were obtained at 25.0-38.6 weeks of gestation within 48 hours of delivery, stored in Digital Imaging and Communication in Medicine format, and analyzed with quantusFLM. Physicians were blinded to the analysis. At delivery, perinatal outcomes and the occurrence of neonatal respiratory morbidity, defined as either respiratory distress syndrome or transient tachypnea of the newborn, were registered. The performance of the ultrasound texture analysis test to predict neonatal respiratory morbidity was evaluated. A total of 883 images were collected, but 17.3% were discarded because of poor image quality or exclusion criteria, leaving 730 observations for the final analysis. The prevalence of neonatal respiratory morbidity was 13.8% (101 of 730). The quantusFLM predicted neonatal respiratory morbidity with a sensitivity, specificity, positive and negative predictive values of 74.3% (75 of 101), 88.6% (557 of 629), 51.0% (75 of 147), and 95.5% (557 of 583), respectively. Accuracy was 86.5% (632 of 730) and positive and negative likelihood ratios were 6.5 and 0.3, respectively. The quantusFLM predicted neonatal respiratory morbidity with an accuracy similar to that previously reported for other tests with the advantage of being a noninvasive technique. Copyright © 2017. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alves, Vinicius M.; Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599; Muratov, Eugene
Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putativemore » sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative chemical hazards in the Scorecard database were found using our models.« less
Bernecker, Samantha L; Rosellini, Anthony J; Nock, Matthew K; Chiu, Wai Tat; Gutierrez, Peter M; Hwang, Irving; Joiner, Thomas E; Naifeh, James A; Sampson, Nancy A; Zaslavsky, Alan M; Stein, Murray B; Ursano, Robert J; Kessler, Ronald C
2018-04-03
High rates of mental disorders, suicidality, and interpersonal violence early in the military career have raised interest in implementing preventive interventions with high-risk new enlistees. The Army Study to Assess Risk and Resilience in Servicemembers (STARRS) developed risk-targeting systems for these outcomes based on machine learning methods using administrative data predictors. However, administrative data omit many risk factors, raising the question whether risk targeting could be improved by adding self-report survey data to prediction models. If so, the Army may gain from routinely administering surveys that assess additional risk factors. The STARRS New Soldier Survey was administered to 21,790 Regular Army soldiers who agreed to have survey data linked to administrative records. As reported previously, machine learning models using administrative data as predictors found that small proportions of high-risk soldiers accounted for high proportions of negative outcomes. Other machine learning models using self-report survey data as predictors were developed previously for three of these outcomes: major physical violence and sexual violence perpetration among men and sexual violence victimization among women. Here we examined the extent to which this survey information increases prediction accuracy, over models based solely on administrative data, for those three outcomes. We used discrete-time survival analysis to estimate a series of models predicting first occurrence, assessing how model fit improved and concentration of risk increased when adding the predicted risk score based on survey data to the predicted risk score based on administrative data. The addition of survey data improved prediction significantly for all outcomes. In the most extreme case, the percentage of reported sexual violence victimization among the 5% of female soldiers with highest predicted risk increased from 17.5% using only administrative predictors to 29.4% adding survey predictors, a 67.9% proportional increase in prediction accuracy. Other proportional increases in concentration of risk ranged from 4.8% to 49.5% (median = 26.0%). Data from an ongoing New Soldier Survey could substantially improve accuracy of risk models compared to models based exclusively on administrative predictors. Depending upon the characteristics of interventions used, the increase in targeting accuracy from survey data might offset survey administration costs.
Shariati, Farzaneh; Aryana, Kamran; Fattahi, Asiehsadat; Forghani, Mohammad N; Azarian, Azita; Zakavi, Seyed R; Sadeghi, Ramin; Ayati, Narjes; Sadri, Keyvan
2014-06-01
In this study, we evaluated the diagnostic accuracy of (99m)Tc-bombesin scintigraphy for differentiation of benign from malignant palpable breast lesions. (99m)Tc-Bombesin is a tracer with high affinity for gastrin-releasing peptide receptor, which is overexpressed on a variety of human tumors including breast carcinoma. We examined 33 consecutive women who were referred to our center with suspicious palpable breast lesions but had no definitive diagnosis in other imaging procedures. A volume of 370-444 MBq of (99m)Tc-bombesin was injected and dynamic 1-min images were taken for 20 min immediately after injection in anterior view. Thereafter, two static images in anterior and prone-lateral views were taken for 5 min. Finally, single-photon emission computed tomography images were taken for each patient. Definitive diagnosis was based on biopsy and histopathological evaluation. The scan findings were positive in 19 patients and negative in 11 on visual assessment of the planar and single-photon emission computed tomography images. Pathologic examination confirmed breast carcinoma in 12 patients with positive scans and benign pathology for 18 patients. The overall sensitivity, specificity, negative and positive predictive values, and accuracy of this radiotracer for diagnosis of breast cancer were 100, 66.1, 100, 63, and 76%, respectively. Semiquantitative analysis improved the specificity of the visual assessment from 66 to 84%. Our study showed that (99m)Tc-bombesin scintigraphy has a high sensitivity and negative predictive value for detecting malignant breast lesions, but the specificity and positive predictive value of this radiotracer for differentiation of malignant breast abnormalities from benign ones are relatively low.
Lee, Youn Joo; Lim, Yeon Soo; Lim, Hyun Wook; Yoo, Won Jong; Choi, Byung Gil; Kim, Bum Soo
2014-10-01
There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48-90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Transmembrane protein topology prediction using support vector machines.
Nugent, Timothy; Jones, David T
2009-05-26
Alpha-helical transmembrane (TM) proteins are involved in a wide range of important biological processes such as cell signaling, transport of membrane-impermeable molecules, cell-cell communication, cell recognition and cell adhesion. Many are also prime drug targets, and it has been estimated that more than half of all drugs currently on the market target membrane proteins. However, due to the experimental difficulties involved in obtaining high quality crystals, this class of protein is severely under-represented in structural databases. In the absence of structural data, sequence-based prediction methods allow TM protein topology to be investigated. We present a support vector machine-based (SVM) TM protein topology predictor that integrates both signal peptide and re-entrant helix prediction, benchmarked with full cross-validation on a novel data set of 131 sequences with known crystal structures. The method achieves topology prediction accuracy of 89%, while signal peptides and re-entrant helices are predicted with 93% and 44% accuracy respectively. An additional SVM trained to discriminate between globular and TM proteins detected zero false positives, with a low false negative rate of 0.4%. We present the results of applying these tools to a number of complete genomes. Source code, data sets and a web server are freely available from http://bioinf.cs.ucl.ac.uk/psipred/. The high accuracy of TM topology prediction which includes detection of both signal peptides and re-entrant helices, combined with the ability to effectively discriminate between TM and globular proteins, make this method ideally suited to whole genome annotation of alpha-helical transmembrane proteins.
Instrument for evaluation of sedentary lifestyle in patients with high blood pressure.
Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; de Araujo, Thelma Leite; Guedes, Nirla Gomes; Martins, Larissa Castelo Guedes; Teixeira, Iane Ximenes
2015-01-01
this article describes the diagnostic accuracy of the International Physical Activity Questionnaire to identify the nursing diagnosis of sedentary lifestyle. a diagnostic accuracy study was developed with 240 individuals with established high blood pressure. The analysis of diagnostic accuracy was based on measures of sensitivity, specificity, predictive values, likelihood ratios, efficiency, diagnostic odds ratio, Youden index, and area under the receiver-operating characteristic curve. statistical differences between genders were observed for activities of moderate intensity and for total physical activity. Age was negatively correlated with activities of moderate intensity and total physical activity. the analysis of area under the receiver-operating characteristic curve for moderate intensity activities, walking, and total physical activity showed that the International Physical Activity Questionnaire present moderate capacity to correctly classify individuals with and without sedentary lifestyle.
Prestimulus alpha-band power biases visual discrimination confidence, but not accuracy.
Samaha, Jason; Iemi, Luca; Postle, Bradley R
2017-09-01
The magnitude of power in the alpha-band (8-13Hz) of the electroencephalogram (EEG) prior to the onset of a near threshold visual stimulus predicts performance. Together with other findings, this has been interpreted as evidence that alpha-band dynamics reflect cortical excitability. We reasoned, however, that non-specific changes in excitability would be expected to influence signal and noise in the same way, leaving actual discriminability unchanged. Indeed, using a two-choice orientation discrimination task, we found that discrimination accuracy was unaffected by fluctuations in prestimulus alpha power. Decision confidence, on the other hand, was strongly negatively correlated with prestimulus alpha power. This finding constitutes a clear dissociation between objective and subjective measures of visual perception as a function of prestimulus cortical excitability. This dissociation is predicted by a model where the balance of evidence supporting each choice drives objective performance but only the magnitude of evidence supporting the selected choice drives subjective reports, suggesting that human perceptual confidence can be suboptimal with respect to tracking objective accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.
Predicting protein-binding regions in RNA using nucleotide profiles and compositions.
Choi, Daesik; Park, Byungkyu; Chae, Hanju; Lee, Wook; Han, Kyungsook
2017-03-14
Motivated by the increased amount of data on protein-RNA interactions and the availability of complete genome sequences of several organisms, many computational methods have been proposed to predict binding sites in protein-RNA interactions. However, most computational methods are limited to finding RNA-binding sites in proteins instead of protein-binding sites in RNAs. Predicting protein-binding sites in RNA is more challenging than predicting RNA-binding sites in proteins. Recent computational methods for finding protein-binding sites in RNAs have several drawbacks for practical use. We developed a new support vector machine (SVM) model for predicting protein-binding regions in mRNA sequences. The model uses sequence profiles constructed from log-odds scores of mono- and di-nucleotides and nucleotide compositions. The model was evaluated by standard 10-fold cross validation, leave-one-protein-out (LOPO) cross validation and independent testing. Since actual mRNA sequences have more non-binding regions than protein-binding regions, we tested the model on several datasets with different ratios of protein-binding regions to non-binding regions. The best performance of the model was obtained in a balanced dataset of positive and negative instances. 10-fold cross validation with a balanced dataset achieved a sensitivity of 91.6%, a specificity of 92.4%, an accuracy of 92.0%, a positive predictive value (PPV) of 91.7%, a negative predictive value (NPV) of 92.3% and a Matthews correlation coefficient (MCC) of 0.840. LOPO cross validation showed a lower performance than the 10-fold cross validation, but the performance remains high (87.6% accuracy and 0.752 MCC). In testing the model on independent datasets, it achieved an accuracy of 82.2% and an MCC of 0.656. Testing of our model and other state-of-the-art methods on a same dataset showed that our model is better than the others. Sequence profiles of log-odds scores of mono- and di-nucleotides were much more powerful features than nucleotide compositions in finding protein-binding regions in RNA sequences. But, a slight performance gain was obtained when using the sequence profiles along with nucleotide compositions. These are preliminary results of ongoing research, but demonstrate the potential of our approach as a powerful predictor of protein-binding regions in RNA. The program and supporting data are available at http://bclab.inha.ac.kr/RBPbinding .
Constructing better classifier ensemble based on weighted accuracy and diversity measure.
Zeng, Xiaodong; Wong, Derek F; Chao, Lidia S
2014-01-01
A weighted accuracy and diversity (WAD) method is presented, a novel measure used to evaluate the quality of the classifier ensemble, assisting in the ensemble selection task. The proposed measure is motivated by a commonly accepted hypothesis; that is, a robust classifier ensemble should not only be accurate but also different from every other member. In fact, accuracy and diversity are mutual restraint factors; that is, an ensemble with high accuracy may have low diversity, and an overly diverse ensemble may negatively affect accuracy. This study proposes a method to find the balance between accuracy and diversity that enhances the predictive ability of an ensemble for unknown data. The quality assessment for an ensemble is performed such that the final score is achieved by computing the harmonic mean of accuracy and diversity, where two weight parameters are used to balance them. The measure is compared to two representative measures, Kappa-Error and GenDiv, and two threshold measures that consider only accuracy or diversity, with two heuristic search algorithms, genetic algorithm, and forward hill-climbing algorithm, in ensemble selection tasks performed on 15 UCI benchmark datasets. The empirical results demonstrate that the WAD measure is superior to others in most cases.
Constructing Better Classifier Ensemble Based on Weighted Accuracy and Diversity Measure
Chao, Lidia S.
2014-01-01
A weighted accuracy and diversity (WAD) method is presented, a novel measure used to evaluate the quality of the classifier ensemble, assisting in the ensemble selection task. The proposed measure is motivated by a commonly accepted hypothesis; that is, a robust classifier ensemble should not only be accurate but also different from every other member. In fact, accuracy and diversity are mutual restraint factors; that is, an ensemble with high accuracy may have low diversity, and an overly diverse ensemble may negatively affect accuracy. This study proposes a method to find the balance between accuracy and diversity that enhances the predictive ability of an ensemble for unknown data. The quality assessment for an ensemble is performed such that the final score is achieved by computing the harmonic mean of accuracy and diversity, where two weight parameters are used to balance them. The measure is compared to two representative measures, Kappa-Error and GenDiv, and two threshold measures that consider only accuracy or diversity, with two heuristic search algorithms, genetic algorithm, and forward hill-climbing algorithm, in ensemble selection tasks performed on 15 UCI benchmark datasets. The empirical results demonstrate that the WAD measure is superior to others in most cases. PMID:24672402
NASA Astrophysics Data System (ADS)
Cangioli, Filippo; Pennacchi, Paolo; Vannini, Giuseppe; Ciuchicchi, Lorenzo
2018-01-01
The influence of sealing components on the rotordynamic stability of turbomachinery has become a key topic because the oil and gas market is increasingly demanding high rotational speeds and high efficiency. This leads the turbomachinery manufacturers to design higher flexibility ratios and to reduce the clearance of the seals. Accurate prediction of the effective damping of seals is critical to avoid instability problems; in recent years, "negative-swirl" swirl brakes have been used to reverse the circumferential direction of the inlet flow, which changes the sign of the cross-coupled stiffness coefficients and generates stabilizing forces. Experimental tests for a teeth-on-stator labyrinth seal were performed by manufacturers with positive and negative pre-swirl values to investigate the pre-swirl effect on the cross-coupled stiffness coefficient. Those results are used as a benchmark in this paper. To analyse the rotor-fluid interaction in the seals, the bulk-flow numeric approach is more time efficient than computational fluid dynamics (CFD). Although the accuracy of the coefficients prediction in bulk-flow models is satisfactory for liquid phase application, the accuracy of the results strongly depends on the operating conditions in the case of the gas phase. In this paper, the authors propose an improvement in the state-of-the-art bulk-flow model by introducing the effect of the energy equation in the zeroth-order solution to better characterize real gas properties due to the enthalpy variation along the seal cavities. The consideration of the energy equation allows for a better estimation of the coefficients in the case of a negative pre-swirl ratio, therefore, it extend the prediction fidelity over a wide range of operating conditions. The numeric results are also compared to the state-of-the-art bulk-flow model, which highlights the improvement in the model.
NASA Astrophysics Data System (ADS)
Rahardjo, K. D.; Dharmaeizar; Nainggolan, G.; Harimurti, K.
2017-08-01
Research has shown that hemodialysis patients with lung congestion have high morbidity and mortality. Patients were assumed to be free of lung congestion if they had reached their post-dialysis dry weight. Most often, to determine if the patient was free of lung congestion, physical examination was used. However, the accuracy of physical examination in detecting lung congestion has not been established. To compare the capabilities of physical examination and lung ultrasound in detection of lung congestion, cross-sectional data collection was conducted on hemodialysis patients. Analysis was done to obtain proportion, sensitivity, specificity, positive predictive value, negative predictive value, and positive likelihood ratio. Sixty patients participated in this study. The inter observer variation of 20 patients revealed a kappa value of 0.828. When all 60 patients were taken into account, we found that 36 patients (57.1%) had lung congestion. Mild lung congestion was found in 24 (38.1%), and 12 (19%) had a moderate degree of congestion. In the analysis comparing jugular venous pressure to lung ultrasound, we found that sensitivity was 0.47 (0.31-0.63), specificity was 0.73 (0.54-0.86), positive predictive value (PPV) was 0.51 (0.36-0.67), negative predictive value (NPV) was 0.70 (0.49-0.84), positive likelihood ratio (PLR) was 1.75 (0.88-3.47), and the negative likelihood ratio (NLR) was 0.72 (0.47-1.12). In terms of lung auscultation, we found that sensitivity was 0.56 (0.39-0.71), specificity was 0.54 (0.35-0.71), PPV was 0.61 (0.44-0.76), NPV was 0.48 (0.31-0.66), PLR was 1.21 (0.73-2.0), and NLR was 0.82 (0.49-1.38). The results of our study showed that jugular venous distention and lung auscultation examination are not reliable means of detecting lung congestion.
Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad
2016-03-01
The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).
Evaluation of dental pulp sensibility tests in a clinical setting.
Jespersen, James J; Hellstein, John; Williamson, Anne; Johnson, William T; Qian, Fang
2014-03-01
The goal of this project was to evaluate the performance of dental pulp sensibility testing with Endo Ice (1,1,1,2-tetrafluoroethane) and an electric pulp tester (EPT) and to determine the effect of several variables on the reliability of these tests. Data were collected from 656 patients seen in the University of Iowa College of Dentistry Endodontic graduate clinic. The results of pulpal sensibility tests, along with the tooth number, age, sex, number of restored surfaces, presence or absence of clinical or radiographic caries, and reported recent use of analgesic medications, were recorded. The presence of vital tissue within the pulp chamber was used to verify the diagnosis. The Endo Ice results showed accuracy, 0.904; sensitivity, 0.916; specificity, 0.896; positive predictive value, 0.862; and negative predictive value, 0.937. The EPT results showed accuracy, 0.75; sensitivity, 0.84; specificity, 0.74; positive predictive value, 0.58; and negative predictive value, 0.90. Patients aged 21-50 years exhibited a more accurate response to cold testing (P = .0043). Vital teeth with caries responded more accurately to cold testing (P = .0077). There was no statistically significant difference noted with any other variable examined. Pulpal sensibility testing with Endo Ice and EPT are accurate and reliable methods of determining pulpal vitality. Patients aged 21-50 exhibited a more accurate response to cold. Sex, tooth type, number of restored surfaces, presence of caries, and recent analgesic use did not significantly alter the results of pulpal sensibility testing in this study. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Menard, J-P; Mazouni, C; Fenollar, F; Raoult, D; Boubli, L; Bretelle, F
2010-12-01
The purpose of this investigation was to determine the diagnostic accuracy of quantitative real-time polymerase chain reaction (PCR) assay in diagnosing bacterial vaginosis versus the standard methods, the Amsel criteria and the Nugent score. The Amsel criteria, the Nugent score, and results from the molecular tool were obtained independently from vaginal samples of 163 pregnant women who reported abnormal vaginal symptoms before 20 weeks gestation. To determine the performance of the molecular tool, we calculated the kappa value, sensitivity, specificity, and positive and negative predictive values. Either or both of the Amsel criteria (≥3 criteria) and the Nugent score (score ≥7) indicated that 25 women (15%) had bacterial vaginosis, and the remaining 138 women did not. DNA levels of Gardnerella vaginalis or Atopobium vaginae exceeded 10(9) copies/mL or 10(8) copies/mL, respectively, in 34 (21%) of the 163 samples. Complete agreement between both reference methods and high concentrations of G. vaginalis and A. vaginae was found in 94.5% of women (154/163 samples, kappa value = 0.81, 95% confidence interval 0.70-0.81). The nine samples with discordant results were categorized as intermediate flora by the Nugent score. The molecular tool predicted bacterial vaginosis with a sensitivity of 100%, a specificity of 93%, a positive predictive value of 73%, and a negative predictive value of 100%. The quantitative real-time PCR assay shows excellent agreement with the results of both reference methods for the diagnosis of bacterial vaginosis.
Jha, Ashish K; Kumawat, Dal C; Bolya, Yasvant K; Goenka, Mahesh K
2012-09-01
Spontaneous bacterial peritonitis (SBP) requires rapid diagnosis and the initiation of antibiotics. Diagnosis of SBP is usually based on cytobacteriological examination of ascitic fluid. These tests require good laboratory facilities and reporting time of few hours to 1-2 day. However, the 24 h laboratory facilities not widely available in country like India. We evaluated the diagnostic utility of reagent strip (Multistix 10 SG(®)) for rapid diagnosis of SBP. The study was prospectively carried out on patients of cirrhosis with ascites. Bedside leukocyte esterase reagent strip testing was performed on ascitic fluid. Cell count as determined by colorimetric scale of reagent strip was compared with counting chamber method. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Out of 100 patients with cirrhotic ascites, [72 males: 28 female; mean age 44.34 (SD 13.03) years] 18 patients were diagnosed to have SBP by counting chamber method as compared to 14 patients detected to have SBP by reagent strip test ≥++ positive. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of reagent strip ≥++ positive were 77.77%, 95.12%, 77.77%, 95.12% and 92% respectively compared to counting chamber method. Reagent strip to diagnose SBP is very specific but less sensitive as compared to counting chamber method. This can be performed rapidly, easily and efficiently even in remote area of developing countries. This bedside test could be a useful tool for the diagnosis of SBP in country like India.
Severi, Ettore; Maguire, Helen; Ihekweazu, Chikwe; Bickler, Graham; Abubakar, Ibrahim
2016-04-22
In 2012, the United Kingdom (UK) Government announced that the new entrant screening for active tuberculosis (TB) in Heathrow and Gatwick airports would end. Our study objective was to estimate screening yield and diagnostic accuracy, and identify those at risk of active TB after entry. We designed a retrospective cohort study and linked new entrants screened from June 2009 to September 2010 through probabilistic matching with UK Enhanced TB Surveillance (ETS) data (June 2009 to December 2010). Yield was the proportion of cases reported to ETS within three months of airport screening in the screened population. To estimate screening diagnostic accuracy we assessed sensitivity, specificity, positive and negative predictive values. Through Poisson regression we identified groups at increased risk of TB diagnosis after entry. We identified 200,199 screened entrants, of these 59 had suspected TB at screening and were reported within 3 months to ETS (yield = 0.03 %). Sensitivity was 26 %; specificity was 99.7 %; positive predictive value was 13.2 %; negative predictive value was 99.9 %. Overall, 350 entrants were reported in ETS. Persons from countries with annual TB incidence higher than 150 cases per 100,000 population and refugees and asylum seekers were at increased risk of TB diagnosis after entry (population attributable risk 77 and 3 % respectively). Airport screening has very low screening yields, sensitivity and positive predictive value. New entrants coming from countries with annual TB incidence higher than 150 per 100,000 population, refugees and asylum seekers should be prioritised at pre- or post-entry screening.
Temporal trends in symptom experience predict the accuracy of recall PROs
Schneider, Stefan; Broderick, Joan E.; Junghaenel, Doerte U.; Schwartz, Joseph E.; Stone, Arthur A.
2013-01-01
Objective Patient-reported outcome measures with reporting periods of a week or more are often used to evaluate the change of symptoms over time, but the accuracy of recall in the context of change is not well understood. This study examined whether temporal trends in symptoms that occur during the reporting period impact the accuracy of 7-day recall reports. Methods Women with premenstrual symptoms (n = 95) completed daily reports of anger, depression, fatigue, and pain intensity for 4 weeks, as well as 7-day recall reports at the end of each week. Latent class growth analysis was used to categorize recall periods based on the direction and rate of change in the daily reports. Agreement (level differences and correlations) between 7-day recall and aggregated daily scores was compared for recall periods with different temporal trends. Results Recall periods with positive, negative, and flat temporal trends were identified and they varied in accordance with weeks of the menstrual cycle. Replicating previous research, 7-day recall scores were consistently higher than aggregated daily scores, but this level difference was more pronounced for recall periods involving positive and negative trends compared with flat trends. Moreover, correlations between 7-day recall and aggregated daily scores were lower in the presence of positive and negative trends compared with flat trends. These findings were largely consistent for anger, depression, fatigue, and pain intensity. Conclusion Temporal trends in symptoms can influence the accuracy of recall reports and this should be considered in research designs involving change. PMID:23915773
Alborzi, Saeed; Rasekhi, Alireza; Shomali, Zahra; Madadi, Gooya; Alborzi, Mahshid; Kazemi, Mahboobeh; Hosseini Nohandani, Azam
2018-01-01
Abstract To determine the diagnostic accuracy of pelvic magnetic resonance imaging (MRI), transvaginal sonography (TVS), and transrectal sonography (TRS) in diagnosis of deep infiltrating endometriosis (DIE). This diagnostic accuracy study was conducted during a 2-year period including a total number of 317 patients with signs and symptoms of endometriosis. All the patients were evaluated by pelvic MRI, TVS, and TRS in the same center. The criterion standard was considered to be the laparoscopy and histopathologic examination. Of 317 patients being included in the present study, 252 tested positive for DIE. The sensitivity, specificity, positive predictive value, and negative predictive value of TVS was found to be 83.3%, 46.1%, 85.7%, and 41.6%, respectively. These variables were 80.5%, 18.6%, 79.3%, and 19.7% for TRS and 90.4%, 66.1%, 91.2%, and 64.1% for MRI, respectively. MRI had the highest accuracy (85.4%) when compared to TVS (75.7%) and TRS (67.8%). The sensitivity of TRS, TVS, and MRI in uterosacral ligament DIE was 82.8%, 70.9%, and 63.6%, respectively. On the contrary, specificity had a reverse trend, favoring MRI (93.9%, 92.8%, and 89.8% for TVS and TRS, respectively). The results of the present study demonstrated that TVS and TRS have appropriate diagnostic accuracy in diagnosis of DIE comparable to MRI. PMID:29465552
Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus
2014-12-01
Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.
Francesconi, M; Minichino, A; Carrión, R E; Delle Chiaie, R; Bevilacqua, A; Parisi, M; Rullo, S; Bersani, F Saverio; Biondi, M; Cadenhead, K
2017-02-01
Accuracy of risk algorithms for psychosis prediction in "at risk mental state" (ARMS) samples may differ according to the recruitment setting. Standardized criteria used to detect ARMS individuals may lack specificity if the recruitment setting is a secondary mental health service. The authors tested a modified strategy to predict psychosis conversion in this setting by using a systematic selection of trait-markers of the psychosis prodrome in a sample with a heterogeneous ARMS status. 138 non-psychotic outpatients (aged 17-31) were consecutively recruited in secondary mental health services and followed-up for up to 3 years (mean follow-up time, 2.2 years; SD=0.9). Baseline ARMS status, clinical, demographic, cognitive, and neurological soft signs measures were collected. Cox regression was used to derive a risk index. 48% individuals met ARMS criteria (ARMS-Positive, ARMS+). Conversion rate to psychosis was 21% for the overall sample, 34% for ARMS+, and 9% for ARMS-Negative (ARMS-). The final predictor model with a positive predictive validity of 80% consisted of four variables: Disorder of Thought Content, visuospatial/constructional deficits, sensory-integration, and theory-of-mind abnormalities. Removing Disorder of Thought Content from the model only slightly modified the predictive accuracy (-6.2%), but increased the sensitivity (+9.5%). These results suggest that in a secondary mental health setting the use of trait-markers of the psychosis prodrome may predict psychosis conversion with great accuracy despite the heterogeneity of the ARMS status. The use of the proposed predictive algorithm may enable a selective recruitment, potentially reducing duration of untreated psychosis and improving prognostic outcomes. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Rossi, E D; Martini, M; Straccia, P; Bizzarro, T; Fadda, G; Larocca, L M
2016-02-01
Our aim was to evaluate the feasibility and diagnostic accuracy of liquid-based cytology (LBC) on lymph node fine needle aspiration (FNA). FNA may fulfil a challenging role in the evaluation of the majority of primary (benign and malignant) diagnoses as well as metastatic lymph node lesions. Although the morphological features may be quite easily recognized, cytological samples with a scant cellular component may raise some issues. We appraised 263 cytological lymph nodes from different body regions analysed between January and December 2013, including 137 male and 126 female patients, and processed with LBC. The cytological diagnoses included 160 benign and 103 malignant lesions. We reported 35 benign and 73 malignant lesions from 108 with surgical follow-up. The latter malignant series included 68 metastatic lesions, four suspicious for malignancy and one inadequate sample. The cytological diagnoses were supported by 62 conclusive immunocytochemical and 28 molecular analyses. Of the 108 cases, we documented 35 true negatives, 72 true positives, one false negative and no false positives, resulting in 98.6% sensitivity, 100% specificity, 99% diagnostic accuracy, 97.2% negative predictive value and 100% positive predictive value. FNA represents the first diagnostic tool in lymph node management and a reliable approach in order to avoid an excision biopsy. Furthermore, LBC is a feasible method for ancillary tests for which methanol-fixed samples are suitable, such as immunocytochemistry and molecular analysis. © 2014 John Wiley & Sons Ltd.
Clinical use of MRI for the evaluation of acute appendicitis during pregnancy.
Patel, Darshan; Fingard, Jordan; Winters, Sean; Low, Gavin
2017-07-01
The purpose of this study was to determine the diagnostic accuracy of MRI for detecting acute appendicitis in pregnancy in a multi-institution study involving general body MR readers with no specific expertise in MR imaging of the pregnant patient. Retrospective review of MRI examinations on PACS in 42 pregnant patients was evaluated for acute right lower quadrant pain. Three fellowship-trained general body radiologists analyzed the MRI examinations in consensus and attempted to localize the appendix, assess for features of appendicitis, and exclude alternative etiologies for the right lower quadrant pain. Of the 42 MRI examinations, the readers noted 6 cases of acute appendicitis, 16 cases of a normal appendix, and 20 cases involving non-visualization of the appendix but where there were no secondary features of acute appendicitis. Based on the surgical data and clinical follow-up, there were 3 true-positive cases, 3 false-positive cases, 34 true-negative cases, and 2 false-negative cases of acute appendicitis on MRI. This yielded an accuracy of 88.1%, sensitivity of 60%, specificity of 91.9%, positive predictive value of 50%, and negative predictive value of 94.4% for the detection of acute appendicitis in the pregnant patient on MRI. Alternative etiologies for the right lower quadrant pain on MRI included torsion of an ovarian dermoid in 1 case and pyelonephritis in 1 case. MRI is an excellent modality for excluding acute appendicitis in pregnant patients presenting with right lower quadrant pain.
Behairy, Noha H.; Dorgham, Mohsen A.
2008-01-01
The aim of this study was to detect the accuracy of routine magnetic resonance imaging (MRI) done in different centres and its agreement with arthroscopy in meniscal and ligamentous injuries of the knee. We prospectively examined 70 patients ranging in age between 22 and 59 years. History taking, plain X-ray, clinical examination, routine MRI and arthroscopy were done for all patients. Sensitivity, specificity, accuracy, positive and negative predictive values, P value and kappa agreement measures were calculated. We found a sensitivity of 47 and 100%, specificity of 95 and 75% and accuracy of 73 and 78.5%, respectively, for the medial and lateral meniscus. A sensitivity of 77.8%, specificity of 100% and accuracy of 94% was noted for the anterior cruciate ligament (ACL). We found good kappa agreements (0.43 and 0.45) for both menisci and excellent agreement (0.84) for the ACL. MRI shows high accuracy and should be used as the primary diagnostic tool for selection of candidates for arthroscopy. Level of evidence: 4. PMID:18506445
Prediction of Dementia in Primary Care Patients
Jessen, Frank; Wiese, Birgitt; Bickel, Horst; Eiffländer-Gorfer, Sandra; Fuchs, Angela; Kaduszkiewicz, Hanna; Köhler, Mirjam; Luck, Tobias; Mösch, Edelgard; Pentzek, Michael; Riedel-Heller, Steffi G.; Wagner, Michael; Weyerer, Siegfried; Maier, Wolfgang; van den Bussche, Hendrik
2011-01-01
Background Current approaches for AD prediction are based on biomarkers, which are however of restricted availability in primary care. AD prediction tools for primary care are therefore needed. We present a prediction score based on information that can be obtained in the primary care setting. Methodology/Principal Findings We performed a longitudinal cohort study in 3.055 non-demented individuals above 75 years recruited via primary care chart registries (Study on Aging, Cognition and Dementia, AgeCoDe). After the baseline investigation we performed three follow-up investigations at 18 months intervals with incident dementia as the primary outcome. The best set of predictors was extracted from the baseline variables in one randomly selected half of the sample. This set included age, subjective memory impairment, performance on delayed verbal recall and verbal fluency, on the Mini-Mental-State-Examination, and on an instrumental activities of daily living scale. These variables were aggregated to a prediction score, which achieved a prediction accuracy of 0.84 for AD. The score was applied to the second half of the sample (test cohort). Here, the prediction accuracy was 0.79. With a cut-off of at least 80% sensitivity in the first cohort, 79.6% sensitivity, 66.4% specificity, 14.7% positive predictive value (PPV) and 97.8% negative predictive value of (NPV) for AD were achieved in the test cohort. At a cut-off for a high risk population (5% of individuals with the highest risk score in the first cohort) the PPV for AD was 39.1% (52% for any dementia) in the test cohort. Conclusions The prediction score has useful prediction accuracy. It can define individuals (1) sensitively for low cost-low risk interventions, or (2) more specific and with increased PPV for measures of prevention with greater costs or risks. As it is independent of technical aids, it may be used within large scale prevention programs. PMID:21364746
Prediction of dementia in primary care patients.
Jessen, Frank; Wiese, Birgitt; Bickel, Horst; Eiffländer-Gorfer, Sandra; Fuchs, Angela; Kaduszkiewicz, Hanna; Köhler, Mirjam; Luck, Tobias; Mösch, Edelgard; Pentzek, Michael; Riedel-Heller, Steffi G; Wagner, Michael; Weyerer, Siegfried; Maier, Wolfgang; van den Bussche, Hendrik
2011-02-18
Current approaches for AD prediction are based on biomarkers, which are however of restricted availability in primary care. AD prediction tools for primary care are therefore needed. We present a prediction score based on information that can be obtained in the primary care setting. We performed a longitudinal cohort study in 3.055 non-demented individuals above 75 years recruited via primary care chart registries (Study on Aging, Cognition and Dementia, AgeCoDe). After the baseline investigation we performed three follow-up investigations at 18 months intervals with incident dementia as the primary outcome. The best set of predictors was extracted from the baseline variables in one randomly selected half of the sample. This set included age, subjective memory impairment, performance on delayed verbal recall and verbal fluency, on the Mini-Mental-State-Examination, and on an instrumental activities of daily living scale. These variables were aggregated to a prediction score, which achieved a prediction accuracy of 0.84 for AD. The score was applied to the second half of the sample (test cohort). Here, the prediction accuracy was 0.79. With a cut-off of at least 80% sensitivity in the first cohort, 79.6% sensitivity, 66.4% specificity, 14.7% positive predictive value (PPV) and 97.8% negative predictive value of (NPV) for AD were achieved in the test cohort. At a cut-off for a high risk population (5% of individuals with the highest risk score in the first cohort) the PPV for AD was 39.1% (52% for any dementia) in the test cohort. The prediction score has useful prediction accuracy. It can define individuals (1) sensitively for low cost-low risk interventions, or (2) more specific and with increased PPV for measures of prevention with greater costs or risks. As it is independent of technical aids, it may be used within large scale prevention programs.
Genomic prediction based on data from three layer lines using non-linear regression models.
Huang, Heyun; Windig, Jack J; Vereijken, Addie; Calus, Mario P L
2014-11-06
Most studies on genomic prediction with reference populations that include multiple lines or breeds have used linear models. Data heterogeneity due to using multiple populations may conflict with model assumptions used in linear regression methods. In an attempt to alleviate potential discrepancies between assumptions of linear models and multi-population data, two types of alternative models were used: (1) a multi-trait genomic best linear unbiased prediction (GBLUP) model that modelled trait by line combinations as separate but correlated traits and (2) non-linear models based on kernel learning. These models were compared to conventional linear models for genomic prediction for two lines of brown layer hens (B1 and B2) and one line of white hens (W1). The three lines each had 1004 to 1023 training and 238 to 240 validation animals. Prediction accuracy was evaluated by estimating the correlation between observed phenotypes and predicted breeding values. When the training dataset included only data from the evaluated line, non-linear models yielded at best a similar accuracy as linear models. In some cases, when adding a distantly related line, the linear models showed a slight decrease in performance, while non-linear models generally showed no change in accuracy. When only information from a closely related line was used for training, linear models and non-linear radial basis function (RBF) kernel models performed similarly. The multi-trait GBLUP model took advantage of the estimated genetic correlations between the lines. Combining linear and non-linear models improved the accuracy of multi-line genomic prediction. Linear models and non-linear RBF models performed very similarly for genomic prediction, despite the expectation that non-linear models could deal better with the heterogeneous multi-population data. This heterogeneity of the data can be overcome by modelling trait by line combinations as separate but correlated traits, which avoids the occasional occurrence of large negative accuracies when the evaluated line was not included in the training dataset. Furthermore, when using a multi-line training dataset, non-linear models provided information on the genotype data that was complementary to the linear models, which indicates that the underlying data distributions of the three studied lines were indeed heterogeneous.
Rath, Timo; Tontini, Gian E; Vieth, Michael; Nägel, Andreas; Neurath, Markus F; Neumann, Helmut
2016-06-01
In order to reduce time, costs, and risks associated with resection of diminutive colorectal polyps, the American Society for Gastrointestinal Endoscopy (ASGE) recently proposed performance thresholds that new technologies should meet for the accurate real-time assessment of histology of colorectal polyps. In this study, we prospectively assessed whether laser-induced fluorescence spectroscopy (LIFS), using the new WavSTAT4 optical biopsy system, can meet the ASGE criteria. 27 patients undergoing screening or surveillance colonoscopy were included. The histology of 137 diminutive colorectal polyps was predicted in real time using LIFS and findings were compared with the results of conventional histopathological examination. The accuracy of predicting polyp histology with WavSTAT4 was assessed according to the ASGE criteria. The overall accuracy of LIFS using WavSTAT4 for predicting polyp histology was 84.7 % with sensitivity, specificity, and negative predictive value (NPV) of 81.8 %, 85.2 %, and 96.1 %. When only distal colorectal diminutive polyps were considered, the NPV for excluding adenomatous histology increased to 100 % (accuracy 82.4 %, sensitivity 100 %, specificity 80.6 %). On-site, LIFS correctly predicted the recommended surveillance intervals with an accuracy of 88.9 % (24/27 patients) when compared with histology-based United States guideline recommendations; in the 3 patients for whom LIFS- and histopathology-based recommended surveillance intervals differed, LIFS predicted shorter surveillance intervals. From the data of this pilot study, LIFS using the WavSTAT4 system appears accurate enough to allow distal colorectal polyps to be left in place and nearly reaches the threshold to "resect and discard" them without pathologic assessment. WavSTAT4 therefore has the potential to reduce costs and risks associated with the removal of diminutive colorectal polyps. © Georg Thieme Verlag KG Stuttgart · New York.
Iacucci, Marietta; Trovato, Cristina; Daperno, Marco; Akinola, Oluseyi; Greenwald, David; Gross, Seth A; Hoffman, Arthur; Lee, Jeffrey; Lethebe, Brendan C; Lowerison, Mark; Nayor, Jennifer; Neumann, Helmut; Rath, Timo; Sanduleanu, Silvia; Sharma, Prateek; Kiesslich, Ralf; Ghosh, Subrata; Saltzman, John R
2018-03-23
Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. In phase 1, a new simplified endoscopic classification for polyps - Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) - was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp histology before and after training, and univariable/multivariable analysis of the endoscopic features, were performed. In phase 3, the reproducibility of SIMPLE by trainees using different endoscopy platforms was evaluated. Using the SIMPLE classification, the accuracy of experts in predicting polyps was 83 % (95 % confidence interval [CI] 77 % - 88 %) before and 94 % (95 %CI 89 % - 97 %) after training ( P = 0.002). The sensitivity, specificity, positive predictive value, and negative predictive value after training were 97 %, 88 %, 95 %, and 91 %. The interobserver agreement of polyp diagnosis improved from 0.46 (95 %CI 0.30 - 0.64) before to 0.66 (95 %CI 0.48 - 0.82) after training. The trainees demonstrated that the SIMPLE classification is applicable across endoscopy platforms, with similar post-training accuracies for narrow-band imaging NBI classification (0.69; 95 %CI 0.64 - 0.73) and SIMPLE (0.71; 95 %CI 0.67 - 0.75). Using the I-SCAN OE system, the new SIMPLE classification demonstrated a high degree of accuracy for adenoma diagnosis, meeting the ASGE PIVI recommendations. We demonstrated that SIMPLE may be used with either I-SCAN OE or NBI. © Georg Thieme Verlag KG Stuttgart · New York.
Gounder, Prabhu P; Haering, Celia; Bruden, Dana J T; Townshend-Bulson, Lisa; Simons, Brenna C; Spradling, Philip R; McMahon, Brian J
2018-01-01
The aspartate aminotransferase-to-platelet ratio index (APRI) and a fibrosis index calculated using platelets (FIB-4) have been proposed as noninvasive markers of liver fibrosis. To determine APRI/FIB-4 accuracy for predicting histologic liver fibrosis and evaluate whether incorporating change in index improves test accuracy in hepatitis C virus (HCV)-infected Alaska Native persons. Using liver histology as the gold standard, we determined the test characteristics of APRI to predict Metavir ≥F2 fibrosis and FIB-4 to predict Metavir ≥F3 fibrosis. Index discrimination was measured as the area under the receiver operator characteristic curve. We fit a logistic regression model to determine whether incorporating change in APRI/FIB-4 over time improved index discrimination. Among 283 participants, 46% were female, 48% had a body mass index >30, 11% had diabetes mellitus, 8% reported current heavy alcohol use. Participants were infected with HCV genotypes 1 (68%), 2 (17%), or 3 (15%). On liver histology, 30% of study participants had ≥F2 fibrosis and 15% had ≥F3 fibrosis. The positive predictive value of an APRI>1.5/FIB-4>3.25 for identifying fibrosis was 77%/78%. The negative predictive value of an APRI<0.5/FIB-4<1.45 was 91%/87%. The area under the receiver operator characteristic curve of an APRI/FIB-4 for identifying fibrosis was 0.82/0.84. Incorporating change in APRI/FIB-4 did not improve index discrimination. The accuracy of APRI/FIB-4 for identifying liver fibrosis in HCV-infected Alaska Native persons is similar to that reported in other populations and could help prioritize patients for treatment living in areas without access to liver biopsy. Change in APRI/FIB-4 was not predictive of degree of fibrosis.
Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela
2015-05-15
Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.
Assessing Breast Cancer Risk with an Artificial Neural Network
Sepandi, Mojtaba; Taghdir, Maryam; Rezaianzadeh, Abbas; Rahimikazerooni, Salar
2018-04-25
Objectives: Radiologists face uncertainty in making decisions based on their judgment of breast cancer risk. Artificial intelligence and machine learning techniques have been widely applied in detection/recognition of cancer. This study aimed to establish a model to aid radiologists in breast cancer risk estimation. This incorporated imaging methods and fine needle aspiration biopsy (FNAB) for cyto-pathological diagnosis. Methods: An artificial neural network (ANN) technique was used on a retrospectively collected dataset including mammographic results, risk factors, and clinical findings to accurately predict the probability of breast cancer in individual patients. Area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive values were used to evaluate discriminative performance. Result: The network incorporating the selected features performed best (AUC = 0.955). Sensitivity and specificity of the ANN were respectively calculated as 0.82 and 0.90. In addition, negative and positive predictive values were respectively computed as 0.90 and 0.80. Conclusion: ANN has potential applications as a decision-support tool to help underperforming practitioners to improve the positive predictive value of biopsy recommendations. Creative Commons Attribution License
Ko, Kyung Dae; El-Ghazawi, Tarek; Kim, Dongkyu; Morizono, Hiroki
2014-05-01
Motor neuron diseases (MNDs) are a class of progressive neurological diseases that damage the motor neurons. An accurate diagnosis is important for the treatment of patients with MNDs because there is no standard cure for the MNDs. However, the rates of false positive and false negative diagnoses are still very high in this class of diseases. In the case of Amyotrophic Lateral Sclerosis (ALS), current estimates indicate 10% of diagnoses are false-positives, while 44% appear to be false negatives. In this study, we developed a new methodology to profile specific medical information from patient medical records for predicting the progression of motor neuron diseases. We implemented a system using Hbase and the Random forest classifier of Apache Mahout to profile medical records provided by the Pooled Resource Open-Access ALS Clinical Trials Database (PRO-ACT) site, and we achieved 66% accuracy in the prediction of ALS progress.
Prediction of Happy-Sad mood from daily behaviors and previous sleep history.
Sano, Akane; Yu, Amy Z; McHill, Andrew W; Phillips, Andrew J K; Taylor, Sara; Jaques, Natasha; Klerman, Elizabeth B; Picard, Rosalind W
2015-01-01
We collected and analyzed subjective and objective data using surveys and wearable sensors worn day and night from 68 participants for ~30 days each, to address questions related to the relationships among sleep duration, sleep irregularity, self-reported Happy-Sad mood and other daily behavioral factors in college students. We analyzed this behavioral and physiological data to (i) identify factors that classified the participants into Happy-Sad mood using support vector machines (SVMs); and (ii) analyze how accurately sleep duration and sleep regularity for the past 1-5 days classified morning Happy-Sad mood. We found statistically significant associations amongst Sad mood and poor health-related factors. Behavioral factors including the frequency of negative social interactions, and negative emails, and total academic activity hours showed the best performance in separating the Happy-Sad mood groups. Sleep regularity and sleep duration predicted daily Happy-Sad mood with 65-80% accuracy. The number of nights giving the best prediction of Happy-Sad mood varied for different individuals.
Cibinel, Gian Alfonso; Casoli, Giovanna; Elia, Fabrizio; Padoan, Monica; Pivetta, Emanuele; Lupia, Enrico; Goffi, Alberto
2012-02-01
Dyspnea is a common symptom in patients admitted to the Emergency Department (ED), and discriminating between cardiogenic and non-cardiogenic dyspnea is often a clinical dilemma. The initial diagnostic work-up may be inaccurate in defining the etiology and the underlying pathophysiology. The aim of this study was to evaluate the diagnostic accuracy and reproducibility of pleural and lung ultrasound (PLUS), performed by emergency physicians at the time of a patient's initial evaluation in the ED, in identifying cardiac causes of acute dyspnea. Between February and July 2007, 56 patients presenting to the ED with acute dyspnea were prospectively enrolled in this study. In all patients, PLUS was performed by emergency physicians with the purpose of identifying the presence of diffuse alveolar-interstitial syndrome (AIS) or pleural effusion. All scans were later reviewed by two other emergency physicians, expert in PLUS and blinded to clinical parameters, who were the ultimate judges of positivity for diffuse AIS and pleural effusion. A random set of 80 recorded scannings were also reviewed by two inexperienced observers to assess inter-observer variability. The entire medical record was independently reviewed by two expert physicians (an emergency medicine physician and a cardiologist) blinded to the ultrasound (US) results, in order to determine whether, for each patient, dyspnea was due to heart failure, or not. Sensitivity, specificity, and positive/negative predictive values were obtained; likelihood ratio (LR) test was used. Cohen's kappa was used to assess inter-observer agreement. The presence of diffuse AIS was highly predictive for cardiogenic dyspnea (sensitivity 93.6%, specificity 84%, positive predictive value 87.9%, negative predictive value 91.3%). On the contrary, US detection of pleural effusion was not helpful in the differential diagnosis (sensitivity 83.9%, specificity 52%, positive predictive value 68.4%, negative predictive value 72.2%). Finally, the coexistence of diffuse AIS and pleural effusion is less accurate than diffuse AIS alone for cardiogenic dyspnea (sensitivity 81.5%, specificity 82.8%, positive predictive value 81.5%, negative predictive value 82.8%). The positive LR was 5.8 for AIS [95% confidence interval (CI) 4.8-7.1] and 1.7 (95% CI 1.2-2.6) for pleural effusion, negative LR resulted 0.1 (95% CI 0.0-0.4) for AIS and 0.3 (95% CI 0.1-0.8) for pleural effusion. Agreement between experienced and inexperienced operators was 92.2% (p < 0.01) and 95% (p < 0.01) for diagnosis of AIS and pleural effusion, respectively. In early evaluation of patients presenting to the ED with dyspnea, PLUS, performed with the purpose of identifying diffuse AIS, may represent an accurate and reproducible bedside tool in discriminating between cardiogenic and non-cardiogenic dyspnea. On the contrary, US detection of pleural effusions does not allow reliable discrimination between different causes of acute dyspnea in unselected ED patients.
A standardized model for predicting flap failure using indocyanine green dye
NASA Astrophysics Data System (ADS)
Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.
2016-03-01
Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.
The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis
Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M
2017-01-01
The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a “routine” PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures. PMID:29348980
The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis.
Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M
2017-01-01
The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a "routine" PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures.
Nortunen, S; Flinkkilä, T; Lantto, I; Kortekangas, T; Niinimäki, J; Ohtonen, P; Pakarinen, H
2015-08-01
We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination-external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test. For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result. ©2015 The British Editorial Society of Bone & Joint Surgery.
Qeli, Ermir; Omasits, Ulrich; Goetze, Sandra; Stekhoven, Daniel J; Frey, Juerg E; Basler, Konrad; Wollscheid, Bernd; Brunner, Erich; Ahrens, Christian H
2014-08-28
The in silico prediction of the best-observable "proteotypic" peptides in mass spectrometry-based workflows is a challenging problem. Being able to accurately predict such peptides would enable the informed selection of proteotypic peptides for targeted quantification of previously observed and non-observed proteins for any organism, with a significant impact for clinical proteomics and systems biology studies. Current prediction algorithms rely on physicochemical parameters in combination with positive and negative training sets to identify those peptide properties that most profoundly affect their general detectability. Here we present PeptideRank, an approach that uses learning to rank algorithm for peptide detectability prediction from shotgun proteomics data, and that eliminates the need to select a negative dataset for the training step. A large number of different peptide properties are used to train ranking models in order to predict a ranking of the best-observable peptides within a protein. Empirical evaluation with rank accuracy metrics showed that PeptideRank complements existing prediction algorithms. Our results indicate that the best performance is achieved when it is trained on organism-specific shotgun proteomics data, and that PeptideRank is most accurate for short to medium-sized and abundant proteins, without any loss in prediction accuracy for the important class of membrane proteins. Targeted proteomics approaches have been gaining a lot of momentum and hold immense potential for systems biology studies and clinical proteomics. However, since only very few complete proteomes have been reported to date, for a considerable fraction of a proteome there is no experimental proteomics evidence that would allow to guide the selection of the best-suited proteotypic peptides (PTPs), i.e. peptides that are specific to a given proteoform and that are repeatedly observed in a mass spectrometer. We describe a novel, rank-based approach for the prediction of the best-suited PTPs for targeted proteomics applications. By building on methods developed in the field of information retrieval (e.g. web search engines like Google's PageRank), we circumvent the delicate step of selecting positive and negative training sets and at the same time also more closely reflect the experimentalist´s need for selecting e.g. the 5 most promising peptides for targeting a protein of interest. This approach allows to predict PTPs for not yet observed proteins or for organisms without prior experimental proteomics data such as many non-model organisms. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Xueyi; Davidson, Nicholas J.
2011-01-01
Ensemble methods have been widely used to improve prediction accuracy over individual classifiers. In this paper, we achieve a few results about the prediction accuracies of ensemble methods for binary classification that are missed or misinterpreted in previous literature. First we show the upper and lower bounds of the prediction accuracies (i.e. the best and worst possible prediction accuracies) of ensemble methods. Next we show that an ensemble method can achieve > 0.5 prediction accuracy, while individual classifiers have < 0.5 prediction accuracies. Furthermore, for individual classifiers with different prediction accuracies, the average of the individual accuracies determines the upper and lower bounds. We perform two experiments to verify the results and show that it is hard to achieve the upper and lower bounds accuracies by random individual classifiers and better algorithms need to be developed. PMID:21853162
Paulinelli, Regis R; Oliveira, Luis-Fernando P; Freitas-Junior, Ruffo; Soares, Leonardo R
2016-01-01
The objective of the present study was to compare the accuracy of SONOBREAST for the prediction of malignancy in solid breast nodules detected at ultrasonography with that of the BI-RADS system and to assess the agreement between these two methods. This prospective study included 274 women and evaluated 500 breast nodules detected at ultrasonography. The probability of malignancy was calculated based on the SONOBREAST model, available at www.sonobreast.com.br, and on the BI-RADS system, with results being compared with the anatomopathology report. The lesions were considered suspect in 171 cases (34.20%), according to both SONOBREAST and BI-RADS. Agreement between the methods was perfect, as shown by a Kappa coefficient of 1 (p<0.001). SONOBREAST and BI-RADS proved identical insofar as sensitivity (95.40%), specificity (78.69%), positive predictive value (48.54%), negative predictive value (98.78%) and accuracy (81.60%) are concerned. With respect to the categorical variables (BI-RADS categories 3, 4 and 5), the area under the receiver operating characteristic (ROC) curve was 94.41 for SONOBREAST (range 92.20-96.62) and 89.99 for BI-RADS (range 86.60-93.37). The accuracy of the SONOBREAST model is identical to that found with BI-RADS when the same parameters are used with respect to the cut-off point at which malignancy is suspected. Regarding the continuous probability of malignancy with BI-RADS categories 3, 4 and 5, SONOBREAST permits a more precise and individualized evaluation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Perandini, Simone; Soardi, Gian Alberto; Motton, Massimiliano; Rossi, Arianna; Signorini, Manuel; Montemezzi, Stefania
2016-09-01
The aim of this study was to compare classification results from four major risk prediction models in a wide population of incidentally detected solitary pulmonary nodules (SPNs) which were selected to crossmatch inclusion criteria for the selected models. A total of 285 solitary pulmonary nodules with a definitive diagnosis were evaluated by means of four major risk assessment models developed from non-screening populations, namely the Mayo, Gurney, PKUPH and BIMC models. Accuracy was evaluated by receiver operating characteristic (ROC) area under the curve (AUC) analysis. Each model's fitness to provide reliable help in decision analysis was primarily assessed by adopting a surgical threshold of 65 % and an observation threshold of 5 % as suggested by ACCP guidelines. ROC AUC values, false positives, false negatives and indeterminate nodules were respectively 0.775, 3, 8, 227 (Mayo); 0.794, 41, 6, 125 (Gurney); 0.889, 42, 0, 144 (PKUPH); 0.898, 16, 0, 118 (BIMC). Resultant data suggests that the BIMC model may be of greater help than Mayo, Gurney and PKUPH models in preoperative SPN characterization when using ACCP risk thresholds because of overall better accuracy and smaller numbers of indeterminate nodules and false positive results. • The BIMC and PKUPH models offer better characterization than older prediction models • Both the PKUPH and BIMC models completely avoided false negative results • The Mayo model suffers from a large number of indeterminate results.
Mohkam, Kayvan; Malik, Yaseen; Derosas, Carlos; Isaac, John; Marudanayagam, Ravi; Mehrzad, Homoyoon; Mirza, Darius F; Muiesan, Paolo; Roberts, Keith J; Sutcliffe, Robert P
2017-06-01
Endoscopic ultrasound fine needle aspiration (EUS-FNA) and percutaneous transhepatic cholangiographic endobiliary forceps biopsy (PTC-EFB) are valid procedures for histological assessment of proximal biliary strictures (PBS), but their performances have never been compared. This study aimed to compare the diagnostic performance of these two techniques. The diagnostic performances of EUS-FNA and PTC-EFB were compared in a retrospective cohort of patients assessed for PBS from 2011 to 2015 at a single tertiary centre. An inverse probability of treatment weighting (IPTW) was performed to adjust for covariate imbalance. A total of 102 EUS-FNAs and 75 PTC-EFBs (performed in 137 patients) were compared. Patients in the PTC-EFB group had higher preoperative bilirubin (243 versus 169 μmol/l, p = 0.005) and a higher incidence of malignancy (87% versus 67%, p = 0.008). Both techniques showed specificity and positive predictive value of 100%, and similar sensitivity (69% versus 75%, p = 0.45), negative predictive value (58% versus 38%, p = 0.15) and accuracy (78% versus 79%, p = 1.00). After IPTW, the diagnostic performance of the two techniques remained similar. Compared to EUS-FNA, PTC-EFB provides similar sensitivity, negative predictive value and accuracy. It should therefore be considered as the preferred tissue-sampling procedure, if biliary drainage is indicated. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S
2015-11-27
To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Retrospective longitudinal study. B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Positive predictive value of the preschool vision screening programme. Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Deng, Han; Qi, Xingshun; Guo, Xiaozhong
2015-01-01
Abstract Aspartate aminotransferase-to-platelet ratio (APRI), aspartate aminotransferase-to-alanine aminotransferase ratio (AAR), FIB-4, FI, King, Lok, Forns, and FibroIndex scores may be simple and convenient noninvasive diagnostic tests, because they are based on the regular laboratory tests and demographic data. This study aimed to systematically evaluate their diagnostic accuracy for the prediction of varices in liver cirrhosis. All relevant papers were searched via PubMed, EMBASE, CNKI, and Wanfang databases. The area under the summary receiver operating characteristic curve (AUSROC), sensitivity, specificity, positive and negative likelihood ratio (PLR and NLR), and diagnostic odds ratio (DOR) were calculated. Overall, 12, 4, 5, 0, 0, 4, 3, and 1 paper was identified to explore the diagnostic accuracy of APRI, AAR, FIB-4, FI, King, Lok, Forns, and FibroIndex scores, respectively. The AUSROCs of APRI, AAR, FIB-4, Lok, and Forns scores for the prediction of varices were 0.6774, 0.7275, 0.7755, 0.7885, and 0.7517, respectively; and those for the prediction of large varices were 0.7278, 0.7448, 0.7095, 0.7264, and 0.6530, respectively. The diagnostic threshold effects of FIB-4 and Forns scores for the prediction of varices were statistically significant. The sensitivities/specificities/PLRs/NLRs/DORs of APRI, AAR, and Lok scores for the prediction of varices were 0.60/0.67/1.77/0.58/3.13, 0.64/0.63/1.97/0.54/4.18, and 0.74/0.68/2.34/0.40/5.76, respectively. The sensitivities/specificities/PLRs/NLRs/DORs of APRI, AAR, FIB-4, Lok, and Forns scores for the prediction of large varices were 0.65/0.66/2.15/0.47/4.97, 0.68/0.58/2.07/0.54/3.93, 0.62/0.64/2.02/0.56/3.57, 0.78/0.63/2.09/0.37/5.55, and 0.65/0.61/1.62/0.59/2.75, respectively. APRI, AAR, FIB-4, Lok, and Forns scores had low to moderate diagnostic accuracy in predicting the presence of varices in liver cirrhosis. PMID:26496312
Skinner, Sarah
2012-11-01
Magnetic resonance imaging (MRI) is the gold standard in noninvasive investigation of knee pain. It has a very high negative predictive value and may assist in avoiding unnecessary knee arthroscopy; its accuracy in the diagnosis of meniscal and anterior cruciate ligament (ACL) tears is greater than 89%; it has a greater than 90% sensitivity for the detection of medial meniscal tears; and it is probably better at assessing the posterior horn than arthroscopy.
Wang, Chih-Wei; Chu, Yueng-Hsiang; Chiu, Deng-Yiv; Shin, Nieh; Hsu, Hsian-He; Lee, Jih-Chin; Juan, Chun-Jung
2018-06-01
The objective of this article is to propose a Warthin tumor (WT) score to distinguish WTs from other parotid tumors. The study included 78 patients with 92 histologically proven parotid tumors, including 42 WTs, 30 pleomorphic adenomas (PMAs), and 20 carcinomas. Echo-planar DW images were acquired. The WT score, which comprised the mean apparent diffusion coefficient (ADC M ) and the SD of the ADC (ADC SD ) of tumors, patient age, and patient sex, was used to predict WTs. The diagnostic performance of the WT score was evaluated using ROC analyses. Statistical significance was denoted by p < 0.05. With the use of optimized criteria, including an ADC M less than or equal to 1.016 × 10 -3 mm 2 /s (WT score, 1), an ADC SD less than or equal to 0.1171 × 10 -3 mm 2 /s (WT score, 1), patient age older than 49 years (WT score, 1), and male sex (WT score, 1), a WT score greater than 2 had a sensitivity, specificity, positive negative value, negative predictive value, and accuracy of 85.7%, 100.0%, 100.0%, 89.3%, and 93.4%, respectively. The WT score allows parotid WTs to be distinguished from PMAs and carcinomas with high accuracy.
A privacy preserving protocol for tracking participants in phase I clinical trials.
El Emam, Khaled; Farah, Hanna; Samet, Saeed; Essex, Aleksander; Jonker, Elizabeth; Kantarcioglu, Murat; Earle, Craig C
2015-10-01
Some phase 1 clinical trials offer strong financial incentives for healthy individuals to participate in their studies. There is evidence that some individuals enroll in multiple trials concurrently. This creates safety risks and introduces data quality problems into the trials. Our objective was to construct a privacy preserving protocol to track phase 1 participants to detect concurrent enrollment. A protocol using secure probabilistic querying against a database of trial participants that allows for screening during telephone interviews and on-site enrollment was developed. The match variables consisted of demographic information. The accuracy (sensitivity, precision, and negative predictive value) of the matching and its computational performance in seconds were measured under simulated environments. Accuracy was also compared to non-secure matching methods. The protocol performance scales linearly with the database size. At the largest database size of 20,000 participants, a query takes under 20s on a 64 cores machine. Sensitivity, precision, and negative predictive value of the queries were consistently at or above 0.9, and were very similar to non-secure versions of the protocol. The protocol provides a reasonable solution to the concurrent enrollment problems in phase 1 clinical trials, and is able to ensure that personal information about participants is kept secure. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Murphy, B J
2001-06-01
To determine the accuracy of T2*-weighted three-dimensional (3D) gradient-echo articular cartilage imaging in the identification of grades 3 and 4 chondromalacia of the knee. A retrospective evaluation of 80 patients who underwent both arthroscopic and MRI evaluation was performed. The 3D images were interpreted by one observer without knowledge of the surgical results. The medial and lateral femoral condyles, the medial and lateral tibial plateau, the patellar cartilage and trochlear groove were evaluated. MR cartilage images were considered positive if focal reduction of cartilage thickness was present (grade 3 chondromalacia) or if complete loss of cartilage was present (grade 4 chondromalacia). Comparison of the 3D MR results with the arthroscopic findings was performed. Eighty patients were included in the study group. A total of 480 articular cartilage sites were evaluated with MRI and arthroscopy. Results of MR identification of grades 3 and 4 chondromalacia, all sites combined, were: sensitivity 83%, specificity 97%, false negative rate 17%, false positive rate 3%, positive predictive value 87%, negative predictive value 95%, overall accuracy 93%. The results demonstrate that T2*-weighted 3D gradient-echo articular cartilage imaging can identify grades 3 and 4 chondromalacia of the knee.
Wykrzykowska, Joanna J.; Arbab-Zadeh, Armin; Godoy, Gustavo; Miller, Julie M.; Lin, Shezhang; Vavere, Andrea; Paul, Narinder; Niinuma, Hiroyuki; Hoe, John; Brinker, Jeffrey; Khosa, Faisal; Sarwar, Sheryar; Lima, Joao; Clouse, Melvin E.
2012-01-01
OBJECTIVE Evaluations of stents by MDCT from studies performed at single centers have yielded variable results with a high proportion of unassessable stents. The purpose of this study was to evaluate the accuracy of 64-MDCT angiography (MDCTA) in identifying in-stent restenosis in a multicenter trial. MATERIALS AND METHODS The Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography Using 64 Detectors (CORE-64) Multicenter Trial and Registry evaluated the accuracy of 64-MDCTA in assessing 405 patients referred for coronary angiography. A total of 75 stents in 52 patients were assessed: 48 of 75 stents (64%) in 36 of 52 patients (69%) could be evaluated. The prevalence of in-stent restenosis by quantitative coronary angiography (QCA) in this subgroup was 23% (17/75). Eighty percent of the stents were ≤ 3.0 mm in diameter. RESULTS The overall sensitivity, specificity, positive predictive value, and negative predictive value to detect 50% in-stent stenosis visually using MDCT compared with QCA was 33.3%, 91.7%, 57.1%, and 80.5%, respectively, with an overall accuracy of 77.1% for the 48 assessable stents. The ability to evaluate stents on MDCTA varied by stent type: Thick-strut stents such as Bx Velocity were assessable in 50% of the cases; Cypher, 62.5% of the cases; and thinner-strut stents such as Taxus, 75% of the cases. We performed quantitative assessment of in-stent contrast attenuation in Hounsfield units and correlated that value with the quantitative percentage of stenosis by QCA. The correlation coefficient between the average attenuation decrease and ≥ 50% stenosis by QCA was 0.25 (p = 0.073). Quantitative assessment failed to improve the accuracy of MDCT over qualitative assessment. CONCLUSION The results of our study showed that 64-MDCT has poor ability to detect in-stent restenosis in small-diameter stents. Evaluability and negative predictive value were better in large-diameter stents. Thus, 64-MDCT may be appropriate for stent assessment in only selected patients. PMID:20028909
Shem, Kazuko L; Castillo, Kathleen; Wong, Sandra Lynn; Chang, James; Kao, Ming-Chih; Kolakowsky-Hayner, Stephanie A
2012-04-01
To assess the accuracy of bedside swallow evaluation (BSE) compared with videofluorosopic swallow study (VFSS) in diagnosing dysphagia in individuals with tetraplegia due to spinal cord injury (SCI). A prospective diagnostic accuracy study according to STAndards for the Reporting of Diagnostic accuracy studies (STARD) criteria. A county hospital with acute inpatient SCI unit. Thirty-nine subjects with SCI and tetraplegia were enrolled. All of the subjects underwent BSE, and 26 subjects completed the VFSS. Individuals with SCI underwent a BSE followed by a VFSS within 72 hours of the BSE. The subjects were diagnosed as having dysphagia if they had positive findings in either BSE or VFSS. Sensitivity, specificity, and positive and negative predictive values were calculated by using VFSS as the criterion standard. Fifteen subjects (38%) were diagnosed as having dysphagia based on the BSE results. Among the subjects who completed the VFSS, 11 were diagnosed with dysphagia (42%) and 4 were diagnosed with aspiration (10%). Of the 26 subjects who completed both BSE and VFSS, only 1 subject was diagnosed differently compared with BSE (3.8%). Different diet recommendations were made in 4 cases after VFSS versus BSE. Different liquid recommendations were made in 8 cases after VFSS versus BSE. Sensitivity of BSE was 100% (95% confidence interval [CI], 71.5%-100%), specificity was 93.3% (95% CI, 68.1%-99.8%). A positive predictive value of BSE was 91.7% (95% CI, 61.5%-100%), and the negative predictive value was 100% (95% CI, 76.8%-100%). Dysphagia is present in approximately 38% of individuals with acute tetraplegia. Because only one of the 21 subjects was diagnosed differently based on VFSS, we believe that BSE is an appropriate screening tool for dysphagia for individuals with cervical SCI. However, VFSS provided additional information on diet and liquid recommendations, so there appears to be an important clinical role for the VFSS. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Sa, Sha; Li, Jing; Li, Xiaodong; Li, Yongrui; Liu, Xiaoming; Wang, Defeng; Zhang, Huimao; Fu, Yu
2017-08-15
This study aimed to establish and evaluate the efficacy of a prediction model for colorectal cancer T-staging. T-staging was positively correlated with the level of carcinoembryonic antigen (CEA), expression of carbohydrate antigen 19-9 (CA19-9), wall deformity, blurred outer edges, fat infiltration, infiltration into the surrounding tissue, tumor size and wall thickness. Age, location, enhancement rate and enhancement homogeneity were negatively correlated with T-staging. The predictive results of the model were consistent with the pathological gold standard, and the kappa value was 0.805. The total accuracy of staging improved from 51.04% to 86.98% with the proposed model. The clinical, imaging and pathological data of 611 patients with colorectal cancer (419 patients in the training group and 192 patients in the validation group) were collected. A spearman correlation analysis was used to validate the relationship among these factors and pathological T-staging. A prediction model was trained with the random forest algorithm. T staging of the patients in the validation group was predicted by both prediction model and traditional method. The consistency, accuracy, sensitivity, specificity and area under the curve (AUC) were used to compare the efficacy of the two methods. The newly established comprehensive model can improve the predictive efficiency of preoperative colorectal cancer T-staging.
Relationship Between Motor Variability, Accuracy, and Ball Speed in the Tennis Serve
Antúnez, Ruperto Menayo; Hernández, Francisco Javier Moreno; García, Juan Pedro Fuentes; Vaíllo, Raúl Reina; Arroyo, Jesús Sebastián Damas
2012-01-01
The main objective of this study was to analyze the motor variability in the performance of the tennis serve and its relationship to performance outcome. Seventeen male tennis players took part in the research, and they performed 20 serves. Linear and non-linear variability during the hand movement was measured by 3D Motion Tracking. Ball speed was recorded with a sports radar gun and the ball bounces were video recorded to calculate accuracy. The results showed a relationship between the amount of variability and its non-linear structure found in performance of movement and the outcome of the serve. The study also found that movement predictability correlates with performance. An increase in the amount of movement variability could affect the tennis serve performance in a negative way by reducing speed and accuracy of the ball. PMID:23486998
Prestimulus EEG Power Predicts Conscious Awareness But Not Objective Visual Performance
Veniero, Domenica
2017-01-01
Abstract Prestimulus oscillatory neural activity has been linked to perceptual outcomes during performance of psychophysical detection and discrimination tasks. Specifically, the power and phase of low frequency oscillations have been found to predict whether an upcoming weak visual target will be detected or not. However, the mechanisms by which baseline oscillatory activity influences perception remain unclear. Recent studies suggest that the frequently reported negative relationship between α power and stimulus detection may be explained by changes in detection criterion (i.e., increased target present responses regardless of whether the target was present/absent) driven by the state of neural excitability, rather than changes in visual sensitivity (i.e., more veridical percepts). Here, we recorded EEG while human participants performed a luminance discrimination task on perithreshold stimuli in combination with single-trial ratings of perceptual awareness. Our aim was to investigate whether the power and/or phase of prestimulus oscillatory activity predict discrimination accuracy and/or perceptual awareness on a trial-by-trial basis. Prestimulus power (3–28 Hz) was inversely related to perceptual awareness ratings (i.e., higher ratings in states of low prestimulus power/high excitability) but did not predict discrimination accuracy. In contrast, prestimulus oscillatory phase did not predict awareness ratings or accuracy in any frequency band. These results provide evidence that prestimulus α power influences the level of subjective awareness of threshold visual stimuli but does not influence visual sensitivity when a decision has to be made regarding stimulus features. Hence, we find a clear dissociation between the influence of ongoing neural activity on conscious awareness and objective performance. PMID:29255794
Technical and financial evaluation of assays for progesterone in canine practice in the UK.
Moxon, R; Copley, D; England, G C W
2010-10-02
The concentration of progesterone was measured in 60 plasma samples from bitches at various stages of the oestrous cycle, using commercially available quantitative and semi-quantitative ELISA test kits, as well as by two commercial laboratories undertaking radioimmunoassay (RIA). The RIA, which was assumed to be the 'gold standard' in terms of reliability and accuracy, was the most expensive method when analysing more than one sample per week, and had the longest delay in obtaining results, but had minimal requirements for practice staff time. When compared with the RIA, the quantitative ELISA had a strong positive correlation (r=0.97, P<0.05) and a sensitivity and specificity of 70.6 per cent and 100.0 per cent, respectively, and positive and negative predictive values of 100.0 per cent and 71.0 per cent, respectively, with an overall accuracy of 90.0 per cent. This method was the least expensive when analysing five or more samples per week, but had longer turnaround times than that of the semi-quantitative ELISA and required more staff time. When compared with the RIA, the semi-quantitative ELISA had a sensitivity and specificity of 100.0 per cent and 95.5 per cent, respectively, and positive and negative predictive values of 73.9 per cent and 77.8 per cent, respectively, with an overall accuracy of 89.2 per cent. This method was more expensive than the quantitative ELISA when analysing five or more samples per week, but had the shortest turnaround time and low requirements in terms of staff time.
Clinical utility of balloon expulsion test for functional defecation disorders
2016-01-01
Purpose I investigated the diagnostic accuracy of balloon expulsion test (BET) with various techniques to find out the most appropriate method, and tried to confirm its clinical utility in diagnosing functional defecation disorders (FDD) in constipated patients. Methods Eighty-seven patients constituted the study population. FDD was defined when patients had at least two positive findings in defecography, manometry, and electromyography. BET was done 4 times in each patient with 2 different positions and 2 different volumes. The positions were seated position (SP) and left lateral decubitus position (LDP). The volumes were fixed volume (FV) of 60 mL and individualized volume with which patient felt a constant desire to defecate (CDV). The results of BETs with 4 different settings (LDP-FV, LDP-CDV, SP-FV, and SP-CDV) were statistically compared and analyzed. Results Of 87 patients, 23 patients (26.4%) had at least two positive findings in 3 tests and thus were diagnosed to have FDD. On receiver operating characteristic curve analysis, area under curve was highest in BET with SP-FV. With a cutoff value of 30 seconds, the specificity of BET with SP-FV was 86.0%, sensitivity was 73.9%, negative predictive value was 89.8%, positive predictive value was 65.4%, and accuracy rate was 82.8% for diagnosing FDD. Conclusion SP-FV is the most appropriate method for BET. In this setting, BET has a diagnostic accuracy sufficient to identify constipated patients who do not have FDD. Patients with negative results in BET with SP-FV may not need other onerous tests to exclude FDD. PMID:26878016
Clinical utility of balloon expulsion test for functional defecation disorders.
Seong, Moo-Kyung
2016-02-01
I investigated the diagnostic accuracy of balloon expulsion test (BET) with various techniques to find out the most appropriate method, and tried to confirm its clinical utility in diagnosing functional defecation disorders (FDD) in constipated patients. Eighty-seven patients constituted the study population. FDD was defined when patients had at least two positive findings in defecography, manometry, and electromyography. BET was done 4 times in each patient with 2 different positions and 2 different volumes. The positions were seated position (SP) and left lateral decubitus position (LDP). The volumes were fixed volume (FV) of 60 mL and individualized volume with which patient felt a constant desire to defecate (CDV). The results of BETs with 4 different settings (LDP-FV, LDP-CDV, SP-FV, and SP-CDV) were statistically compared and analyzed. Of 87 patients, 23 patients (26.4%) had at least two positive findings in 3 tests and thus were diagnosed to have FDD. On receiver operating characteristic curve analysis, area under curve was highest in BET with SP-FV. With a cutoff value of 30 seconds, the specificity of BET with SP-FV was 86.0%, sensitivity was 73.9%, negative predictive value was 89.8%, positive predictive value was 65.4%, and accuracy rate was 82.8% for diagnosing FDD. SP-FV is the most appropriate method for BET. In this setting, BET has a diagnostic accuracy sufficient to identify constipated patients who do not have FDD. Patients with negative results in BET with SP-FV may not need other onerous tests to exclude FDD.
Lucas, Rita; Lopes Dias, João; Cunha, Teresa Margarida
2015-01-01
We aimed to evaluate the added value of diffusion-weighted imaging (DWI) to standard magnetic resonance imaging (MRI) for detecting post-treatment cervical cancer recurrence. The detection accuracy of T2-weighted (T2W) images was compared with that of T2W MRI combined with either dynamic contrast-enhanced (DCE) MRI or DWI. Thirty-eight women with clinically suspected uterine cervical cancer recurrence more than six months after treatment completion were examined with 1.5 Tesla MRI including T2W, DCE, and DWI sequences. Disease was confirmed histologically and correlated with MRI findings. The diagnostic performance of T2W imaging and its combination with either DCE or DWI were analyzed. Sensitivity, positive predictive value, and accuracy were calculated. Thirty-six women had histologically proven recurrence. The accuracy for recurrence detection was 80% with T2W/DCE MRI and 92.1% with T2W/DWI. The addition of DCE sequences did not significantly improve the diagnostic ability of T2W imaging, and this sequence combination misclassified two patients as falsely positive and seven as falsely negative. The T2W/DWI combination revealed a positive predictive value of 100% and only three false negatives. The addition of DWI to T2W sequences considerably improved the diagnostic ability of MRI. Our results support the inclusion of DWI in the initial MRI protocol for the detection of cervical cancer recurrence, leaving DCE sequences as an option for uncertain cases.
Dermoscopy improves accuracy of primary care physicians to triage lesions suggestive of skin cancer.
Argenziano, Giuseppe; Puig, Susana; Zalaudek, Iris; Sera, Francesco; Corona, Rosamaria; Alsina, Mercè; Barbato, Filomena; Carrera, Cristina; Ferrara, Gerardo; Guilabert, Antonio; Massi, Daniela; Moreno-Romero, Juan A; Muñoz-Santos, Carlos; Petrillo, Gianluca; Segura, Sonia; Soyer, H Peter; Zanchini, Renato; Malvehy, Josep
2006-04-20
Primary care physicians (PCPs) constitute an appropriate target for new interventions and educational campaigns designed to increase skin cancer screening and prevention. The aim of this randomized study was to determine whether the adjunct of dermoscopy to the standard clinical examination improves the accuracy of PCPs to triage lesions suggestive of skin cancer. PCPs in Barcelona, Spain, and Naples, Italy, were given a 1-day training course in skin cancer detection and dermoscopic evaluation, and were randomly assigned to the dermoscopy evaluation arm or naked-eye evaluation arm. During a 16-month period, 73 physicians evaluated 2,522 patients with skin lesions who attended their clinics and scored individual lesions as benign or suggestive of skin cancer. All patients were re-evaluated by expert dermatologists at clinics for pigmented lesions. Referral accuracy of both PCP groups was calculated by their scores, which were compared to those tabulated for dermatologists. Referral sensitivity, specificity, and positive and negative predictive values were 54.1%, 71.3%, 11.3%, and 95.8%, respectively, in the naked-eye arm, and 79.2%, 71.8%, 16.1%, and 98.1%, respectively, in the dermoscopy arm. Significant differences were found in terms of sensitivity and negative predictive value (P = .002 and P = .004, respectively). Histopathologic examination of equivocal lesions revealed 23 malignant skin tumors missed by PCPs performing naked-eye observation and only six by PCPs using dermoscopy (P = .002). The use of dermoscopy improves the ability of PCPs to triage lesions suggestive of skin cancer without increasing the number of unnecessary expert consultations.
Is intestinal biopsy always needed for diagnosis of celiac disease?
Scoglio, Riccardo; Di Pasquale, Giuseppe; Pagano, Giuseppe; Lucanto, Maria Cristina; Magazzù, Giuseppe; Sferlazzas, Concetta
2003-06-01
Intestinal biopsy is required for a diagnosis of celiac disease (CD). The aim of this study was to assess diagnostic accuracy of transglutaminase antibodies (TGA) in comparison and in association with that of antiemdomysial antibodies (AEA), calculating the post-test odds of having the disease, to verify whether some patients might avoid undergoing intestinal biopsy for a diagnosis of CD. A total of 181 consecutive patients (131 < 18 yr), referred to our celiac clinic by primary care physicians for suspect CD. Overall diagnostic accuracy, negative predictive value, and likelihood ratio (LR) were calculated both for each serological test and for serial testing (TGA and after AEA, assuming the post-test probability of TGA as pretest probability of AEA). Both serological determination and histological evaluation were blindly performed. Histology of duodenal mucosa was considered the gold standard. The overall accuracy of TGA and of AEA were 92.8% (89.1-96.6) and 93.4% (89.7-97.0), respectively. The negative predictive value of TGA and AEA were 97.2% (91.9-102.6) and 87.2% (77.7-96.8), respectively. Positive likelihood ratios for TGA and AEA were 3.89 (3.40-4.38) and 7.48 (6.73-8.23), respectively. Serial testing, in groups of patients with prevalence of CD estimated higher than 75%, such as those with classic symptoms of CD, would provide a post-test probability of more than 99%. Our results suggest that serial testing with TGA and AEA might allow, in some cases, the avoidance of intestinal biopsy to confirm the diagnosis of CD.
Serrano-Gomez, Sergio; Burgos-Angulo, Gabriel; Niño-Vargas, Daniela Camila; Niño, María Eugenia; Cárdenas, María Eugenia; Chacón-Valenzuela, Estephania; McCosham, Diana Margarita; Peinado-Acevedo, Juan Sebastián; Lopez, M Marcos; Cunha, Fernando; Pazin-Filho, Antonio; Ilarraza, Ramses; Schulz, Richard; Torres-Dueñas, Diego
2017-01-01
Over 170 biomarkers are being investigated regarding their prognostic and diagnostic accuracy in sepsis in order to find new tools to reduce morbidity and mortality. Matrix metalloproteinases (MMPs) and their inhibitors have been recently studied as promising new prognostic biomarkers in patients with sepsis. This study is aimed at determining the utility of several cutoff points of these biomarkers to predict mortality in patients with sepsis. A multicenter, prospective, analytic cohort study was performed in the metropolitan area of Bucaramanga, Colombia. A total of 289 patients with sepsis and septic shock were included. MMP-9, MMP-2, tissue inhibitor of metalloproteinase 1 (TIMP-1), TIMP-2, TIMP-1/MMP-9 ratio, and TIMP-2/MMP-2 ratio were determined in blood samples. Value ranges were correlated with mortality to estimate sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiving operating characteristic curve. Sensitivity ranged from 33.3% (MMP-9/TIMP-1 ratio) to 60.6% (TIMP-1) and specificity varied from 38.8% (MMP-2/TIMP-2 ratio) to 58.5% (TIMP-1). As for predictive values, positive predictive value range was from 17.5% (MMP-9/TIMP-1 ratio) to 70.4% (MMP-2/TIMP-2 ratio), whereas negative predictive values were between 23.2% (MMP-2/TIMP-2 ratio) and 80.9% (TIMP-1). Finally, area under the curve scores ranged from 0.31 (MMP-9/TIMP-1 ratio) to 0.623 (TIMP-1). Although TIMP-1 showed higher sensitivity, specificity, and negative predictive value, with a representative population sample, we conclude that none of the evaluated biomarkers had significant predictive value for mortality.
Dong, Fei; Zeng, Qiang; Jiang, Biao; Yu, Xinfeng; Wang, Weiwei; Xu, Jingjing; Yu, Jinna; Li, Qian; Zhang, Minming
2018-05-01
To study whether some of the quantitative enhancement and necrosis features in preoperative conventional MRI (cMRI) had a predictive value for epidermal growth factor receptor (EGFR) gene amplification status in glioblastoma multiforme (GBM).Fifty-five patients with pathologically determined GBMs who underwent cMRI were retrospectively reviewed. The following cMRI features were quantitatively measured and recorded: long and short diameters of the enhanced portion (LDE and SDE), maximum and minimum thickness of the enhanced portion (MaxTE and MinTE), and long and short diameters of the necrotic portion (LDN and SDN). Univariate analysis of each feature and a decision tree model fed with all the features were performed. Area under the receiver operating characteristic (ROC) curve (AUC) was used to assess the performance of features, and predictive accuracy was used to assess the performance of the model.For single feature, MinTE showed the best performance in differentiating EGFR gene amplification negative (wild-type) (nEGFR) GBM from EGFR gene amplification positive (pEGFR) GBM, and it got an AUC of 0.68 with a cut-off value of 2.6 mm. The decision tree model included 2 features MinTE and SDN, and got an accuracy of 0.83 in validation dataset.Our results suggest that quantitative measurement of the features MinTE and SDN in preoperative cMRI had a high accuracy for predicting EGFR gene amplification status in GBM.
NASA Astrophysics Data System (ADS)
Xu, Chong; Dai, Fuchu; Xu, Xiwei; Lee, Yuan Hsi
2012-04-01
Support vector machine (SVM) modeling is based on statistical learning theory. It involves a training phase with associated input and target output values. In recent years, the method has become increasingly popular. The main purpose of this study is to evaluate the mapping power of SVM modeling in earthquake triggered landslide-susceptibility mapping for a section of the Jianjiang River watershed using a Geographic Information System (GIS) software. The river was affected by the Wenchuan earthquake of May 12, 2008. Visual interpretation of colored aerial photographs of 1-m resolution and extensive field surveys provided a detailed landslide inventory map containing 3147 landslides related to the 2008 Wenchuan earthquake. Elevation, slope angle, slope aspect, distance from seismogenic faults, distance from drainages, and lithology were used as the controlling parameters. For modeling, three groups of positive and negative training samples were used in concert with four different kernel functions. Positive training samples include the centroids of 500 large landslides, those of all 3147 landslides, and 5000 randomly selected points in landslide polygons. Negative training samples include 500, 3147, and 5000 randomly selected points on slopes that remained stable during the Wenchuan earthquake. The four kernel functions are linear, polynomial, radial basis, and sigmoid. In total, 12 cases of landslide susceptibility were mapped. Comparative analyses of landslide-susceptibility probability and area relation curves show that both the polynomial and radial basis functions suitably classified the input data as either landslide positive or negative though the radial basis function was more successful. The 12 generated landslide-susceptibility maps were compared with known landslide centroid locations and landslide polygons to verify the success rate and predictive accuracy of each model. The 12 results were further validated using area-under-curve analysis. Group 3 with 5000 randomly selected points on the landslide polygons, and 5000 randomly selected points along stable slopes gave the best results with a success rate of 79.20% and predictive accuracy of 79.13% under the radial basis function. Of all the results, the sigmoid kernel function was the least skillful when used in concert with the centroid data of all 3147 landslides as positive training samples, and the negative training samples of 3147 randomly selected points in regions of stable slope (success rate = 54.95%; predictive accuracy = 61.85%). This paper also provides suggestions and reference data for selecting appropriate training samples and kernel function types for earthquake triggered landslide-susceptibility mapping using SVM modeling. Predictive landslide-susceptibility maps could be useful in hazard mitigation by helping planners understand the probability of landslides in different regions.
Clinical Value of Prognosis Gene Expression Signatures in Colorectal Cancer: A Systematic Review
Cordero, David; Riccadonna, Samantha; Solé, Xavier; Crous-Bou, Marta; Guinó, Elisabet; Sanjuan, Xavier; Biondo, Sebastiano; Soriano, Antonio; Jurman, Giuseppe; Capella, Gabriel; Furlanello, Cesare; Moreno, Victor
2012-01-01
Introduction The traditional staging system is inadequate to identify those patients with stage II colorectal cancer (CRC) at high risk of recurrence or with stage III CRC at low risk. A number of gene expression signatures to predict CRC prognosis have been proposed, but none is routinely used in the clinic. The aim of this work was to assess the prediction ability and potential clinical usefulness of these signatures in a series of independent datasets. Methods A literature review identified 31 gene expression signatures that used gene expression data to predict prognosis in CRC tissue. The search was based on the PubMed database and was restricted to papers published from January 2004 to December 2011. Eleven CRC gene expression datasets with outcome information were identified and downloaded from public repositories. Random Forest classifier was used to build predictors from the gene lists. Matthews correlation coefficient was chosen as a measure of classification accuracy and its associated p-value was used to assess association with prognosis. For clinical usefulness evaluation, positive and negative post-tests probabilities were computed in stage II and III samples. Results Five gene signatures showed significant association with prognosis and provided reasonable prediction accuracy in their own training datasets. Nevertheless, all signatures showed low reproducibility in independent data. Stratified analyses by stage or microsatellite instability status showed significant association but limited discrimination ability, especially in stage II tumors. From a clinical perspective, the most predictive signatures showed a minor but significant improvement over the classical staging system. Conclusions The published signatures show low prediction accuracy but moderate clinical usefulness. Although gene expression data may inform prognosis, better strategies for signature validation are needed to encourage their widespread use in the clinic. PMID:23145004
Hassanpour, Saeed; Langlotz, Curtis P
2016-01-01
Imaging utilization has significantly increased over the last two decades, and is only recently showing signs of moderating. To help healthcare providers identify patients at risk for high imaging utilization, we developed a prediction model to recognize high imaging utilizers based on their initial imaging reports. The prediction model uses a machine learning text classification framework. In this study, we used radiology reports from 18,384 patients with at least one abdomen computed tomography study in their imaging record at Stanford Health Care as the training set. We modeled the radiology reports in a vector space and trained a support vector machine classifier for this prediction task. We evaluated our model on a separate test set of 4791 patients. In addition to high prediction accuracy, in our method, we aimed at achieving high specificity to identify patients at high risk for high imaging utilization. Our results (accuracy: 94.0%, sensitivity: 74.4%, specificity: 97.9%, positive predictive value: 87.3%, negative predictive value: 95.1%) show that a prediction model can enable healthcare providers to identify in advance patients who are likely to be high utilizers of imaging services. Machine learning classifiers developed from narrative radiology reports are feasible methods to predict imaging utilization. Such systems can be used to identify high utilizers, inform future image ordering behavior, and encourage judicious use of imaging. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Ensemble-based prediction of RNA secondary structures.
Aghaeepour, Nima; Hoos, Holger H
2013-04-24
Accurate structure prediction methods play an important role for the understanding of RNA function. Energy-based, pseudoknot-free secondary structure prediction is one of the most widely used and versatile approaches, and improved methods for this task have received much attention over the past five years. Despite the impressive progress that as been achieved in this area, existing evaluations of the prediction accuracy achieved by various algorithms do not provide a comprehensive, statistically sound assessment. Furthermore, while there is increasing evidence that no prediction algorithm consistently outperforms all others, no work has been done to exploit the complementary strengths of multiple approaches. In this work, we present two contributions to the area of RNA secondary structure prediction. Firstly, we use state-of-the-art, resampling-based statistical methods together with a previously published and increasingly widely used dataset of high-quality RNA structures to conduct a comprehensive evaluation of existing RNA secondary structure prediction procedures. The results from this evaluation clarify the performance relationship between ten well-known existing energy-based pseudoknot-free RNA secondary structure prediction methods and clearly demonstrate the progress that has been achieved in recent years. Secondly, we introduce AveRNA, a generic and powerful method for combining a set of existing secondary structure prediction procedures into an ensemble-based method that achieves significantly higher prediction accuracies than obtained from any of its component procedures. Our new, ensemble-based method, AveRNA, improves the state of the art for energy-based, pseudoknot-free RNA secondary structure prediction by exploiting the complementary strengths of multiple existing prediction procedures, as demonstrated using a state-of-the-art statistical resampling approach. In addition, AveRNA allows an intuitive and effective control of the trade-off between false negative and false positive base pair predictions. Finally, AveRNA can make use of arbitrary sets of secondary structure prediction procedures and can therefore be used to leverage improvements in prediction accuracy offered by algorithms and energy models developed in the future. Our data, MATLAB software and a web-based version of AveRNA are publicly available at http://www.cs.ubc.ca/labs/beta/Software/AveRNA.
Islam, M S; Sultana, T; Paul, D; Huq, A H M Z; Chowdhury, A A; Ferdous, C; Ahmed, A N N
2012-12-01
Postoperative hypocalcaemia is the most frequent and common complication after total thyroidectomy. It is necessary to diagnose or to predict hypocalcaemia immediately after total thyroidectomy for minimizing complications. A prospective observational study was carried out in the Department of Clinical Pathology in collaboration with Department of Microbiology & Immunology, Department of Surgery, Department of Otolaryngology, Bangabandhu Sheikh Mujib Medical University (BSMMU) and Department of Otolaryngology, Dhaka Medical College & Hospital (DMC&H), Dhaka, during the period of September 2010 to August 2011 to evaluate intraoperative (20 minutes after total thyroidectomy) parathyroid hormone (PTH) measurement as a predictor of post thyroidectomy hypocalcaemia. Total 65 patients were enrolled in this study those came for total thyroidectomy. Postoperative hypocalcaemia developed in 25 cases. Intraoperative PTH was assessed and significant correlation was found between intraoperative PTH level and development of hypocalcaemia. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value of intraoperative serum PTH for prediction of post total thyroidectomy hypocalcaemia were 84.0%, 85.0%, 84.6%, 77.8%, and 89.5% respectively. Because of the high sensitivity, specificity and accuracy of intraoperative serum PTH of this study, the early prediction of hypocalcaemia could be made by single assay of intraoperative serum PTH level at 20 minutes after total thyroidectomy.
Sadikaj, Gentiana; Moskowitz, D S; Zuroff, David C
2015-08-01
High intrapersonal variability has frequently been found to be related to poor personal and interpersonal outcomes. Little research has examined processes by which intrapersonal variability influences outcomes. This study explored the relation of intrapersonal variability in negative affect (negative affect flux) to accuracy and bias in the perception of a romantic partner's quarrelsome behavior. A sample of 93 cohabiting couples participated in a study using an event-contingent recording (ECR) methodology in which they reported their negative affect, quarrelsome behavior, and perception of their partner's quarrelsome behavior in interactions with each other during a 20-day period. Negative affect flux was operationalized as the within-person standard deviation of negative affect scores across couple interactions. Findings suggested that participants were both accurate in tracking changes in their partner's quarrelsome behavior and biased in assuming their partner's quarrelsome behavior mirrored their own quarrelsome behavior. Negative affect flux moderated both accuracy and bias of assumed similarity such that participants with higher flux manifested both greater tracking accuracy and larger bias of assumed similarity. Negative affect flux may be related to enhanced vigilance to close others' negative behavior, which may explain higher tracking accuracy and propensity to rely on a person's own negative behavior as a means of judging others' negative behavior. These processes may augment these individuals' negative interpersonal behavior, enhance cycles of negative social interactions, and lead to poor intrapersonal and interpersonal outcomes.
Magnetic Resonance Enterography to Assess Multifocal and Multicentric Bowel Endometriosis.
Nyangoh Timoh, Krystel; Stewart, Zelda; Benjoar, Mikhael; Beldjord, Selma; Ballester, Marcos; Bazot, Marc; Thomassin-Naggara, Isabelle; Darai, Emile
To prospectively determine the accuracy of magnetic resonance enterography (MRE) compared with conventional magnetic resonance imaging (MRI) for multifocal (i.e., multiple lesions affecting the same digestive segment) and multicentric (i.e., multiple lesions affecting several digestive segments) bowel endometriosis. A prospective study (Canadian Task Force classification II-2). Tenon University Hospital, Paris, France. Patients with MRI-suspected colorectal endometriosis scheduled for colorectal resection from April 2014 to February 2016 were included. Patients underwent both 1.5-Tesla MRI and MRE as well as laparoscopically assisted and open colorectal resections. The diagnostic performance of MRI and MRE was evaluated for sensitivity, specificity, positive and negative predictive values, accuracy, and positive and negative likelihood ratios (LRs). The interobserver variability of the experienced and junior radiologists was quantified using weighted statistics. Forty-seven patients were included. Twenty-two (46.8%) patients had unifocal lesions, 14 (30%) had multifocal lesions, and 11 (23.4%) had multicentric lesions. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multifocal lesions were 0.29 (6/21), 1.00 (23/24), 15.36, and 0.71 for MRI and 0.57 (12/21), 0.89 (23/25), 4.95, and 0.58 for MRE. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multicentric lesions were 0.18 (1/11), 1.00 (1/1), 15, and 0.80 for MRI and 0.46 (5/11), 0.92 (33/36), 5.45, and 0.60 for MRE. Lower accuracies for MRI compared with MRE to diagnose multicentric (p = .01) and multifocal lesions (p = .004) were noted. The interobserver agreement for MRE was good for both multifocality (κ = 0.80) and multicentricity (κ = 0.61). MRE has better accuracy for diagnosing multifocal and multicentric bowel endometriosis than conventional MRI. Copyright © 2018. Published by Elsevier Inc.
Xu, Yongsong; Wang, Runze; Zhu, Mengmeng; Li, Xuexue; Pan, Xiaodong; Ni, Tong; Zhou, Shusheng
2018-01-01
To investigate the diagnostic value of dynamic-extended focused assessment with sonography for trauma (D-EFAST) in patients with multiple trauma in intensive care unit (ICU). A prospective clinical study was conducted. Eighty patients with multiple trauma admitted to ICU of Anhui Provincial Hospital from September 1st, 2014 to December 31st, 2016 were enrolled. Extended focused assessment with sonography for trauma (E-FAST) check was conducted at first, for those who had positive findings diagnosis was confirmed by immediately CT examination or surgical exploration. If it was negative, the patients received E-FAST every morning for 7 days (defined as D-EFAST), for those with positive findings, immediately CT or surgery was performed to clarify the diagnosis. The final clinical diagnosis was used as the "gold standard" to calculate the diagnostic accordance rate of EFAST and D-EFAST examination technique for pneumothorax, pleural effusion, spleen injury, kidney damage, liver damage, gastrointestinal injury, pericardial effusion, bladder rupture, and pancreatic injury, as well as their sensitivity, specificity, positive predictive value, negative predictive value, accuracy rate, and missed diagnosis rate, and the difference between EFAST and D-EFAST was compared. There were 4 patients excluded because of death and abandoning treatment, and finally 76 patients were included in the study. The total sensitivity of E-FAST examination technique for pneumothorax, pleural effusion, spleen injury, liver damage, gastrointestinal injury, pericardial effusion, and bladder rupture was 75.9% (66/87), and the specificity was 98.3% (587/597), the positive predictive value was 86.8% (66/76), and the negative predictive value was 96.5% (587/608), the accuracy rate was 95.5% (653/684), and the rate of missed diagnosis was 24.1% (21/87). The most of the delayed injury in patients with multiple trauma occurred at 2-7 days after injury with incidence of 4.8% (33/684). The diagnostic sensitivity of D-EFAST for delayed injury was 98.3% (118/120), the specificity was 99.8% (563/564), the positive predictive value was 99.2% (118/119), the negative predictive value was 99.6% (563/565), the diagnostic accuracy rate was 99.6% (681/684), and rate of missed diagnosis was 1.7% (2/120). When the final clinical diagnosis was set as the "gold standard", D-EFAST technology for the detection rate was 98.3% (118/120) for patients with multiple trauma on organ injury while the detection rate of E-FAST was 75.9% (66/87), with statistical significant difference (P < 0.01), indicating that D-EFAST was better than E-FAST in check of multiple trauma patients with organ injury. Although the E-FAST technology can quickly diagnose the multiple trauma patients and win the rescue time for critical patients, multiple trauma patients injured after 2-7 days prone to delayed damage and are difficult to detect, and D-EFAST can be used to find delayed damage earlier, and reduce the misdiagnosis rate of multiple trauma patients.
Imaging markers for Alzheimer disease
Bocchetta, Martina; Chételat, Gael; Rabinovici, Gil D.; de Leon, Mony J.; Kaye, Jeffrey; Reiman, Eric M.; Scheltens, Philip; Barkhof, Frederik; Black, Sandra E.; Brooks, David J.; Carrillo, Maria C.; Fox, Nick C.; Herholz, Karl; Nordberg, Agneta; Jack, Clifford R.; Jagust, William J.; Johnson, Keith A.; Rowe, Christopher C.; Sperling, Reisa A.; Thies, William; Wahlund, Lars-Olof; Weiner, Michael W.; Pasqualetti, Patrizio; DeCarli, Charles
2013-01-01
Revised diagnostic criteria for Alzheimer disease (AD) acknowledge a key role of imaging biomarkers for early diagnosis. Diagnostic accuracy depends on which marker (i.e., amyloid imaging, 18F-fluorodeoxyglucose [FDG]-PET, SPECT, MRI) as well as how it is measured (“metric”: visual, manual, semiautomated, or automated segmentation/computation). We evaluated diagnostic accuracy of marker vs metric in separating AD from healthy and prognostic accuracy to predict progression in mild cognitive impairment. The outcome measure was positive (negative) likelihood ratio, LR+ (LR−), defined as the ratio between the probability of positive (negative) test outcome in patients and the probability of positive (negative) test outcome in healthy controls. Diagnostic LR+ of markers was between 4.4 and 9.4 and LR− between 0.25 and 0.08, whereas prognostic LR+ and LR− were between 1.7 and 7.5, and 0.50 and 0.11, respectively. Within metrics, LRs varied up to 100-fold: LR+ from approximately 1 to 100; LR− from approximately 1.00 to 0.01. Markers accounted for 11% and 18% of diagnostic and prognostic variance of LR+ and 16% and 24% of LR−. Across all markers, metrics accounted for an equal or larger amount of variance than markers: 13% and 62% of diagnostic and prognostic variance of LR+, and 29% and 18% of LR−. Within markers, the largest proportion of diagnostic LR+ and LR− variability was within 18F-FDG-PET and MRI metrics, respectively. Diagnostic and prognostic accuracy of imaging AD biomarkers is at least as dependent on how the biomarker is measured as on the biomarker itself. Standard operating procedures are key to biomarker use in the clinical routine and drug trials. PMID:23897875
Diagnostic Accuracy of a Self-Report Measure of Patellar Tendinopathy in Youth Basketball.
Owoeye, Oluwatoyosi B A; Wiley, J Preston; Walker, Richard E A; Palacios-Derflingher, Luz; Emery, Carolyn A
2018-04-27
Study Design Prospective diagnostic accuracy validation study. Background Engaging clinicians for diagnosis of patellar tendinopathy in large surveillance studies is often impracticable. A self-report measure, the Oslo Sports Research Trauma Centre patellar tendinopathy (OSTRC-P) Questionnaire, an adaptation of the OSTRC Questionnaire may provide a viable alternative. Objectives To evaluate the diagnostic accuracy of the OSTRC-P Questionnaire in detecting patellar tendinopathy in youth basketball players when compared to clinical evaluation. Methods Following the Standards for Reporting of Diagnostic Accuracy Studies guidelines, 208 youth basketball players (aged 13-18 years) were recruited. Participants completed the OSTRC-P Questionnaire (index test) prior to a clinical evaluation (reference standard) by a physiotherapist blinded to OSTRC-P Questionnaire results. Sensitivity, specificity, predictive values (PVs), likelihood ratios (LRs) and posttest probabilities were calculated. Linear regression was used to examine the association between OSTRC-P Questionnaire severity score and patellar tendinopathy severity rating during single leg decline squat (SLDS). Results The final analysis included 169 players. The OSTRC-P Questionnaire had a sensitivity of 79% (95%CI: 65%, 90%), specificity of 98% (95%CI: 94%, 100%), positive PV of 95%, negative PV of 92%, positive LR of 48 and negative LR of 0.21. The posttest probabilities were 95% and 8% given positive and negative results, respectively. A positive association was found between OSTRC-P Questionnaire and SLDS rating [(β = .08 (95%CI: .03, .12) (p = .001)]. Conclusions The OSTRC-P Questionnaire is an acceptable alternative to clinical evaluation for self-reporting patellar tendinopathy and grading its severity in settings involving youth basketball players. Level of Evidence Diagnosis, level 1b. J Orthop Sports Phys Ther, Epub 27 Apr 2018. doi:10.2519/jospt.2018.8088.
Diagnostic Accuracy of B-mode USG and Doppler Scan for Ovarian Lesions
Agarwal, Vinish Kumar
2016-01-01
Introduction Ultrasonography (USG) is considered as the primary imaging modality for confirmation of ovarian mass and to differentiate them in to benign or malignant. Aim The present study was conducted with the aim to evaluate accuracy of B- mode USG and Doppler scan (Colour Doppler + Spectral Doppler) for ovarian lesions. Materials and Methods The patients included in the study were from those referred with either palpable adnexal mass or incidentally detected adnexal masses. Total 250 women were evaluated by USG, Doppler scan. Only fifty patients who had true ovarian mass intraoperatively and on histopathology were included in study, rest masses were excluded. Study parameters were morphological indexing on B- Mode USG, flow study, vessel arrangement, and vessel morphology and vessel location in Colour Doppler and resistive index and pulsatility index in spectral Doppler. Results Total 50 women were included in present study. Out of these 46% were pre-menopausal while 54% were menopaused women, 66.7% of post-menopausal women had malignant ovarian masses compared to 8.7% of premenopausal. Sensitivity, specificity, positive predictive value and negative predictive value of B-Mode USG for ovarian masses were 94.44%, 48.15%, 54.84% and 92.86% respectively, with p-value = 0.007, while sensitivity, specificity, positive predictive value and negative predictive value of Doppler scan were 85%, 90%, 85% and 90% respectively, with p-value = 0.0001. Conclusion USG and its different techniques are accepted as the primary imaging modality for early stage diagnosis of an ovarian malignancy. Statistical analysis suggests that Doppler Scan (Colour + Spectral) was more accurate (88%) than B-Mode USG (67%), but author is in view that both of these modalities should be used in conjunction to screen the ovarian lesions. PMID:27790544
NASA Astrophysics Data System (ADS)
Yasami, Yasser; Safaei, Farshad
2018-02-01
The traditional complex network theory is particularly focused on network models in which all network constituents are dealt with equivalently, while fail to consider the supplementary information related to the dynamic properties of the network interactions. This is a main constraint leading to incorrect descriptions of some real-world phenomena or incomplete capturing the details of certain real-life problems. To cope with the problem, this paper addresses the multilayer aspects of dynamic complex networks by analyzing the properties of intrinsically multilayered co-authorship networks, DBLP and Astro Physics, and presenting a novel multilayer model of dynamic complex networks. The model examines the layers evolution (layers birth/death process and lifetime) throughout the network evolution. Particularly, this paper models the evolution of each node's membership in different layers by an Infinite Factorial Hidden Markov Model considering feature cascade, and thereby formulates the link generation process for intra-layer and inter-layer links. Although adjacency matrixes are useful to describe the traditional single-layer networks, such a representation is not sufficient to describe and analyze the multilayer dynamic networks. This paper also extends a generalized mathematical infrastructure to address the problems issued by multilayer complex networks. The model inference is performed using some Markov Chain Monte Carlo sampling strategies, given synthetic and real complex networks data. Experimental results indicate a tremendous improvement in the performance of the proposed multilayer model in terms of sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios, F1-score, Matthews correlation coefficient, and accuracy for two important applications of missing link prediction and future link forecasting. The experimental results also indicate the strong predictivepower of the proposed model for the application of cascade prediction in terms of accuracy.
Zapatier, Jorge A; Gómez, Néstor A; Vargas, Paola E; Maya, Susana V
2007-06-01
The infection with Helicobacter pylori (H. pylori), and the diagnostic efficacy of the serologic tests has certain variability among the different geographic regions. The objective of the present work was to find the local validation of serological methods for diagnosis of H. pylori infection and to determine the best cutoff value for the local population. Forty-eight patients were evaluated, 27 males and 21 females, with a mean age of 29.2 years. On each patient, 3 tests for H. pylori diagnosis were performed: IgG serology, IgA serology and histology. We performed IgG and IgA serologic test for H. pylori infection and a histological examination for each patient. Efficacy parameters as well as the ROC curve were obtained for the IgG and IgA serology using histology as the gold standard. The cutoff point with the highest efficacy for IgG serology was 16 U/ml (sensitivity 81%, specificity 65%, positive predictive value 81%, negative predictive value 65%, and accuracy 75%), and for IgA serology was 17 U/ml (sensitivity 61%, specificity 53%, positive predictive value 70%, negative predictive value 43%, and accuracy 58%). The area under the curve was 67.1% (CI 95%: 50 to 84.1) and 54.4% (CI 95%: 38.3 to 72.5) for IgG and IgA respectively. The serology is a valuable tool in our population with high prevalence of H. pylori, especially due to its low cost and easy performance, but a reduction ofthe cutoff value was necessary to obtain more sensibility and a more adequate identification of true positives cases.
Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L
2009-04-22
Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.
Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.
Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia
2009-01-01
Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.
Haiducek, John D.; Welling, Daniel T.; Ganushkina, Natalia Y.; ...
2017-10-30
We simulated the entire month of January, 2005 using the Space Weather Modeling Framework (SWMF) with observed solar wind data as input. We conducted this simulation with and without an inner magnetosphere model, and tested two different grid resolutions. We evaluated the model's accuracy in predicting Kp, Sym-H, AL, and cross polar cap potential (CPCP). We find that the model does an excellent job of predicting the Sym-H index, with an RMSE of 17-18 nT. Kp is predicted well during storm-time conditions, but over-predicted during quiet times by a margin of 1 to 1.7 Kp units. AL is predicted reasonablymore » well on average, with an RMSE of 230-270 nT. However, the model reaches the largest negative AL values significantly less often than the observations. The model tended to over-predict CPCP, with RMSE values on the order of 46-48 kV. We found the results to be insensitive to grid resoution, with the exception of the rate of occurrence for strongly negative AL values. As a result, the use of the inner magnetosphere component, however, affected results significantly, with all quantities except CPCP improved notably when the inner magnetosphere model was on.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haiducek, John D.; Welling, Daniel T.; Ganushkina, Natalia Y.
We simulated the entire month of January, 2005 using the Space Weather Modeling Framework (SWMF) with observed solar wind data as input. We conducted this simulation with and without an inner magnetosphere model, and tested two different grid resolutions. We evaluated the model's accuracy in predicting Kp, Sym-H, AL, and cross polar cap potential (CPCP). We find that the model does an excellent job of predicting the Sym-H index, with an RMSE of 17-18 nT. Kp is predicted well during storm-time conditions, but over-predicted during quiet times by a margin of 1 to 1.7 Kp units. AL is predicted reasonablymore » well on average, with an RMSE of 230-270 nT. However, the model reaches the largest negative AL values significantly less often than the observations. The model tended to over-predict CPCP, with RMSE values on the order of 46-48 kV. We found the results to be insensitive to grid resoution, with the exception of the rate of occurrence for strongly negative AL values. As a result, the use of the inner magnetosphere component, however, affected results significantly, with all quantities except CPCP improved notably when the inner magnetosphere model was on.« less
Okasha, Hussein; Elkholy, Shaimaa; El-Sayed, Ramy; Wifi, Mohamed-Naguib; El-Nady, Mohamed; El-Nabawi, Walid; El-Dayem, Waleed A; Radwan, Mohamed I; Farag, Ali; El-Sherif, Yahya; Al-Gemeie, Emad; Salman, Ahmed; El-Sherbiny, Mohamed; El-Mazny, Ahmed; Mahdy, Reem E
2017-08-28
To evaluate the accuracy of the elastography score combined to the strain ratio in the diagnosis of solid pancreatic lesions (SPL). A total of 172 patients with SPL identified by endoscopic ultrasound were enrolled in the study to evaluate the efficacy of elastography and strain ratio in differentiating malignant from benign lesions. The semi quantitative score of elastography was represented by the strain ratio method. Two areas were selected, area (A) representing the region of interest and area (B) representing the normal area. Area (B) was then divided by area (A). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by comparing diagnoses made by elastography, strain ratio and final diagnoses. SPL were shown to be benign in 49 patients and malignant in 123 patients. Elastography alone had a sensitivity of 99%, a specificity of 63%, and an accuracy of 88%, a PPV of 87% and an NPV of 96%. The best cut-off level of strain ratio to obtain the maximal area under the curve was 7.8 with a sensitivity of 92%, specificity of 77%, PPV of 91%, NPV of 80% and an accuracy of 88%. Another estimated cut off strain ratio level of 3.8 had a higher sensitivity of 99% and NPV of 96%, but with less specificity, PPV and accuracy 53%, 84% and 86%, respectively. Adding both elastography to strain ratio resulted in a sensitivity of 98%, specificity of 77%, PPV of 91%, NPV of 95% and accuracy of 92% for the diagnosis of SPL. Combining elastography to strain ratio increases the accuracy of the differentiation of benign from malignant SPL.
Okasha, Hussein; Elkholy, Shaimaa; El-Sayed, Ramy; Wifi, Mohamed-Naguib; El-Nady, Mohamed; El-Nabawi, Walid; El-Dayem, Waleed A; Radwan, Mohamed I; Farag, Ali; El-sherif, Yahya; Al-Gemeie, Emad; Salman, Ahmed; El-Sherbiny, Mohamed; El-Mazny, Ahmed; Mahdy, Reem E
2017-01-01
AIM To evaluate the accuracy of the elastography score combined to the strain ratio in the diagnosis of solid pancreatic lesions (SPL). METHODS A total of 172 patients with SPL identified by endoscopic ultrasound were enrolled in the study to evaluate the efficacy of elastography and strain ratio in differentiating malignant from benign lesions. The semi quantitative score of elastography was represented by the strain ratio method. Two areas were selected, area (A) representing the region of interest and area (B) representing the normal area. Area (B) was then divided by area (A). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by comparing diagnoses made by elastography, strain ratio and final diagnoses. RESULTS SPL were shown to be benign in 49 patients and malignant in 123 patients. Elastography alone had a sensitivity of 99%, a specificity of 63%, and an accuracy of 88%, a PPV of 87% and an NPV of 96%. The best cut-off level of strain ratio to obtain the maximal area under the curve was 7.8 with a sensitivity of 92%, specificity of 77%, PPV of 91%, NPV of 80% and an accuracy of 88%. Another estimated cut off strain ratio level of 3.8 had a higher sensitivity of 99% and NPV of 96%, but with less specificity, PPV and accuracy 53%, 84% and 86%, respectively. Adding both elastography to strain ratio resulted in a sensitivity of 98%, specificity of 77%, PPV of 91%, NPV of 95% and accuracy of 92% for the diagnosis of SPL. CONCLUSION Combining elastography to strain ratio increases the accuracy of the differentiation of benign from malignant SPL. PMID:28932088
Clinical accuracy of point-of-care urine culture in general practice.
Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller; Jessen, Lisbeth Rem; Frimodt-Møller, Niels; Siersma, Volkert; Bjerrum, Lars
2017-06-01
To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. Prospective diagnostic accuracy study comparing two index tests (Flexicult™ SSI-Urinary Kit or ID Flexicult™) with a reference standard (urine culture performed in the microbiological department). General practice in the Copenhagen area patients. Adult female patients consulting their general practitioner with suspected uncomplicated, symptomatic UTI. (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply in boric acid used for transportation for the reference standard. (4) Accuracy based on expert reading of photographs of POC urine cultures performed in general practice. Standard culture performed in the microbiological department was used as reference standard for all four measures. Twenty general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci excluded was 0.82 (0.77-0.86) and agreement between expert readings of photographs and reference results was 0.81 (CI: 0.76-0.85). POC culture used in general practice has high SEN but low SPE. Low SPE could be due to both misinterpretation in general practice and an imperfect reference standard. Registration number: ClinicalTrials.gov NCT02323087.
[Diagnostic value of cardiac magnetic resonance in patients with acute viral myocarditis].
Ouyang, Haichun; Chen, Haixiong; Hu, Yunzhao; Wu, Yanxian; Li, Wensheng; Chen, Yuying; Cen, Yujian
2014-11-01
To assess the diagnostic value of cardiac magnetic resonance (CMR) in patients with acute viral myocarditis. Thirty patients with suspected acute viral myocarditis admitted in first people's hospital of Shunde from June 2011 to June 2013 were included in this prospective study. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of acute viral myocarditis were evaluated by clinical diagnosis. Diagnostic value among different scan methods and Lake Louise criteria were compared. Acute viral myocarditis was diagnosed in 63.33% (19/30) patients.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 57.89%, 72.73%, 78.57%, 50.00%, 63.33%, respectively by edema imaging (ER).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 63.64%, 78.95%, 63.64%, 73.33%, respectively using global relative enhancement (gRE).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 54.55%, 75.00%, 60.00%, 70.00%, respectively using late gadolinium enhancement (LGE) criteria.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 84.21%, 81.82%, 88.89%, 75.00%, 83.33% using Lake Louise criteria. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy using Lake Louise criteria were significantly higher than using ER, gRE, LGE alone(all P < 0.05).Specificity was higher using ER than using gRE and LGE (both P < 0.05). The sensitivity, NPV, and diagnostic accuracy were significantly higher using gRE than using ER (all P < 0.05) and was similar as using LGE (all P > 0.05). Cardiac magnetic resonance is an excellent imaging modality for the diagnosis of acute viral myocarditis.
NEOadjuvant therapy monitoring with PET and CT in Esophageal Cancer (NEOPEC-trial)
2008-01-01
Background Surgical resection is the preferred treatment of potentially curable esophageal cancer. To improve long term patient outcome, many institutes apply neoadjuvant chemoradiotherapy. In a large proportion of patients no response to chemoradiotherapy is achieved. These patients suffer from toxic and ineffective neoadjuvant treatment, while appropriate surgical therapy is delayed. For this reason a diagnostic test that allows for accurate prediction of tumor response early during chemoradiotherapy is of crucial importance. CT-scan and endoscopic ultrasound have limited accuracy in predicting histopathologic tumor response. Data suggest that metabolic changes in tumor tissue as measured by FDG-PET predict response better. This study aims to compare FDG-PET and CT-scan for the early prediction of non-response to preoperative chemoradiotherapy in patients with potentially curable esophageal cancer. Methods/design Prognostic accuracy study, embedded in a randomized multicenter Dutch trial comparing neoadjuvant chemoradiotherapy for 5 weeks followed by surgery versus surgery alone for esophageal cancer. This prognostic accuracy study is performed only in the neoadjuvant arm of the randomized trial. In 6 centers, 150 consecutive patients will be included over a 3 year period. FDG-PET and CT-scan will be performed before and 2 weeks after the start of the chemoradiotherapy. All patients complete the 5 weeks regimen of neoadjuvant chemoradiotherapy, regardless the test results. Pathological examination of the surgical resection specimen will be used as reference standard. Responders are defined as patients with < 10% viable residual tumor cells (Mandard-score). Difference in accuracy (area under ROC curve) and negative predictive value between FDG-PET and CT-scan are primary endpoints. Furthermore, an economic evaluation will be performed, comparing survival and costs associated with the use of FDG-PET (or CT-scan) to predict tumor response with survival and costs of neoadjuvant chemoradiotherapy without prediction of response (reference strategy). Discussion The NEOPEC-trial could be the first sufficiently powered study that helps justify implementation of FDG-PET for response-monitoring in patients with esophageal cancer in clinical practice. Trial registration ISRCTN45750457 PMID:18671847
Kumar, Gyanendra; Shahripour, Reza Bavarsad; Harrigan, Mark R
2016-05-01
OBJECT The impact of transcranial Doppler (TCD) ultrasonography evidence of vasospasm on patient-centered clinical outcomes following aneurysmal subarachnoid hemorrhage (aSAH) is unknown. Vasospasm is known to lead to delayed cerebral ischemia (DCI) and poor outcomes. This systematic review and meta-analysis evaluates the predictive value of vasospasm on DCI, as diagnosed on TCD. METHODS MEDLINE, Scopus, the Cochrane trial register, and clinicaltrials.gov were searched through September 2014 using key words and the terms "subarachnoid hemorrhage," "aneurysm," "aneurysmal," "cerebral vasospasm," "vasospasm," "transcranial Doppler," and "TCD." Sensitivities, specificities, and positive and negative predictive values were pooled by a DerSimonian and Laird random-effects model. RESULTS Seventeen studies (n = 2870 patients) met inclusion criteria. The amount of variance attributable to heterogeneity was significant (I(2) > 50%) for all syntheses. No studies reported the impact of TCD evidence of vasospasm on functional outcome or mortality. TCD evidence of vasospasm was found to be highly predictive of DCI. Pooled estimates for TCD diagnosis of vasospasm (for DCI) were sensitivity 90% (95% confidence interval [CI] 77%-96%), specificity 71% (95% CI 51%-84%), positive predictive value 57% (95% CI 38%-71%), and negative predictive value 92% (95% CI 83%-96%). CONCLUSIONS TCD evidence of vasospasm is predictive of DCI with high accuracy. Although high sensitivity and negative predictive value make TCD an ideal monitoring device, it is not a mandated standard of care in aSAH due to the paucity of evidence on clinically relevant outcomes, despite recommendation by national guidelines. High-quality randomized trials evaluating the impact of TCD monitoring on patient-centered and physician-relevant outcomes are needed.
Spencer, Brian A; Dolinskas, Carol A; Seymour, Peter A; Thomas, Stephen J; Abboud, Joseph A
2013-09-01
The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Rezaei-Darzi, Ehsan; Farzadfar, Farshad; Hashemi-Meshkini, Amir; Navidi, Iman; Mahmoudi, Mahmoud; Varmaghani, Mehdi; Mehdipour, Parinaz; Soudi Alamdari, Mahsa; Tayefi, Batool; Naderimagham, Shohreh; Soleymani, Fatemeh; Mesdaghinia, Alireza; Delavari, Alireza; Mohammad, Kazem
2014-12-01
This study aimed to evaluate and compare the prediction accuracy of two data mining techniques, including decision tree and neural network models in labeling diagnosis to gastrointestinal prescriptions in Iran. This study was conducted in three phases: data preparation, training phase, and testing phase. A sample from a database consisting of 23 million pharmacy insurance claim records, from 2004 to 2011 was used, in which a total of 330 prescriptions were assessed and used to train and test the models simultaneously. In the training phase, the selected prescriptions were assessed by both a physician and a pharmacist separately and assigned a diagnosis. To test the performance of each model, a k-fold stratified cross validation was conducted in addition to measuring their sensitivity and specificity. Generally, two methods had very similar accuracies. Considering the weighted average of true positive rate (sensitivity) and true negative rate (specificity), the decision tree had slightly higher accuracy in its ability for correct classification (83.3% and 96% versus 80.3% and 95.1%, respectively). However, when the weighted average of ROC area (AUC between each class and all other classes) was measured, the ANN displayed higher accuracies in predicting the diagnosis (93.8% compared with 90.6%). According to the result of this study, artificial neural network and decision tree model represent similar accuracy in labeling diagnosis to GI prescription.
Bustamante, Marco; Devesa, Francesc; Borghol, Abdul; Ortuño, Juan; Ferrando, Maria Jose
2002-07-01
Endoscopic follow-up study of gastric ulcers has been recommended routinely because of the possibility that a gastric neoplasm will be missed in the initial endoscopy. Some authors, most of them reporting data from areas of low gastric carcinoma incidence, have questioned this policy because of the low numbers of curable cancers detected and the high cost of such a program. To assess the accuracy of endoscopy diagnosis of gastric ulcers, and to evaluate the efficacy and cost of a gastric ulcer follow-up endoscopic program in an area with an intermediate incidence rate of gastric cancer. A retrospective study was used to identify all the gastroscopies in which a gastric ulcer had been diagnosed during a 6-year period. The endoscopic impression was compared with the histologic diagnosis, sensitivity, specificity, positive and negative predictive values, and the likelihood ratio. Patients who completed a follow-up program also were reviewed. For each neoplasm discovered, the number of endoscopies and global cost were calculated. In the 741 gastroscopies performed, 547 gastric ulcers were diagnosed in 529 patients. Biopsies were taken in 330 patients, in whom 341 gastric ulcers were found. At the index endoscopy, 41 gastric neoplasms (12.4%) were diagnosed. The accuracy of endoscopic malignancy diagnosis was as follows: positive predictive value of 0.68, negative predictive value of 0.98, sensitivity of 0.82, and specificity of 0.95. The likelihood ratio was 16. A total of 117 patients completed the follow-up program. Three new cases of gastric cancer (2.6%) were identified. In these three cases, the initial opinion of the endoscopist was uncertain. In the authors' experience, the cost of each gastric cancer diagnosed has been $4.653 (U.S. dollars). The endoscopic impression correlates with the histologic diagnosis even in a area of intermediate gastric cancer incidence. Endoscopic follow-up study may be restricted to cases of uncertain or malignant endoscopic impression.
Accuracy of gestalt perception of acute chest pain in predicting coronary artery disease
das Virgens, Cláudio Marcelo Bittencourt; Lemos Jr, Laudenor; Noya-Rabelo, Márcia; Carvalhal, Manuela Campelo; Cerqueira Junior, Antônio Maurício dos Santos; Lopes, Fernanda Oliveira de Andrade; de Sá, Nicole Cruz; Suerdieck, Jéssica Gonzalez; de Souza, Thiago Menezes Barbosa; Correia, Vitor Calixto de Almeida; Sodré, Gabriella Sant'Ana; da Silva, André Barcelos; Alexandre, Felipe Kalil Beirão; Ferreira, Felipe Rodrigues Marques; Correia, Luís Cláudio Lemos
2017-01-01
AIM To test accuracy and reproducibility of gestalt to predict obstructive coronary artery disease (CAD) in patients with acute chest pain. METHODS We studied individuals who were consecutively admitted to our Chest Pain Unit. At admission, investigators performed a standardized interview and recorded 14 chest pain features. Based on these features, a cardiologist who was blind to other clinical characteristics made unstructured judgment of CAD probability, both numerically and categorically. As the reference standard for testing the accuracy of gestalt, angiography was required to rule-in CAD, while either angiography or non-invasive test could be used to rule-out. In order to assess reproducibility, a second cardiologist did the same procedure. RESULTS In a sample of 330 patients, the prevalence of obstructive CAD was 48%. Gestalt’s numerical probability was associated with CAD, but the area under the curve of 0.61 (95%CI: 0.55-0.67) indicated low level of accuracy. Accordingly, categorical definition of typical chest pain had a sensitivity of 48% (95%CI: 40%-55%) and specificity of 66% (95%CI: 59%-73%), yielding a negligible positive likelihood ratio of 1.4 (95%CI: 0.65-2.0) and negative likelihood ratio of 0.79 (95%CI: 0.62-1.02). Agreement between the two cardiologists was poor in the numerical classification (95% limits of agreement = -71% to 51%) and categorical definition of typical pain (Kappa = 0.29; 95%CI: 0.21-0.37). CONCLUSION Clinical judgment based on a combination of chest pain features is neither accurate nor reproducible in predicting obstructive CAD in the acute setting. PMID:28400920
Claessen, Femke M A P; Stoop, Nicky; Doornberg, Job N; Guitton, Thierry G; van den Bekerom, Michel P J; Ring, David
2016-10-01
Stable fixation of distal humerus fracture fragments is necessary for adequate healing and maintenance of reduction. The purpose of this study was to measure the reliability and accuracy of interpretation of postoperative radiographs to predict which implants will loosen or break after operative treatment of bicolumnar distal humerus fractures. We also addressed agreement among surgeons regarding which fracture fixation will loosen or break and the influence of years in independent practice, location of practice, and so forth. A total of 232 orthopedic residents and surgeons from around the world evaluated 24 anteroposterior and lateral radiographs of distal humerus fractures on a Web-based platform to predict which implants would loosen or break. Agreement among observers was measured using the multi-rater kappa measure. The sensitivity of prediction of failure of fixation of distal humerus fracture on radiographs was 63%, specificity was 53%, positive predictive value was 36%, the negative predictive value was 78%, and accuracy was 56%. There was fair interobserver agreement (κ = 0.27) regarding predictions of failure of fixation of distal humerus fracture on radiographs. Interobserver variability did not change when assessed for the various subgroups. When experienced and skilled surgeons perform fixation of type C distal humerus fracture, the immediate postoperative radiograph is not predictive of fixation failure. Reoperation based on the probability of failure might not be advisable. Diagnostic III. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
The diagnosis of acute appendicitis in a pediatric population: to CT or not to CT.
Stephen, Antonia E; Segev, Dorry L; Ryan, Daniel P; Mullins, Mark E; Kim, Samuel H; Schnitzer, Jay J; Doody, Daniel P
2003-03-01
The aim of this study was to determine if focused appendiceal computed tomography with colon contrast (FACT-CC) increases the accuracy of the preoperative diagnosis of acute appendicitis in children. A 5-year retrospective review was conducted of a university hospital database of 283 patients (age 0.8 to 19.3 years; mean, 11.3 years) treated with appendectomy for presumed acute appendicitis. Of the 283 patients in whom appendectomies were performed, 268 were confirmed by pathologic analysis of the specimen to have acute appendicitis for a diagnostic accuracy in our institution of 94.7%. Ninety-six patients (34%) underwent FACT-CC scans as part of their preoperative evaluation. The sensitivity of the computed tomography (CT) scan was 94.6%, and the positive predictive value was 95.6%. In girls older than 10 years, CT imaging was not significantly more accurate in predicting appendicitis than examination alone (93.9% v. 87.5%; P =.46). Preoperative FACT-CC did not increase the accuracy in diagnosing appendicitis when compared with patients diagnosed by history, physical examination and laboratory studies. If there was a strong suspicion of appendicitis, a negative CT scan did not exclude the diagnosis of appendicitis. However, focused appendiceal CT scan is a sensitive test with a high positive predictive value and may be useful in a patient with an atypical history or examination. Copyright 2003, Elsevier Science (USA). All rights reserved.
Accuracy of ultrasound versus computed tomography urogram in detecting urinary tract calculi.
Salinawati, B; Hing, E Y; Fam, X I; Zulfiqar, M A
2015-08-01
To determine the (i) sensitivity and specificity of ultrasound (USG) in the detection of urinary tract calculi, (ii) size of renal calculi detected on USG, and (iii) size of renal calculi not seen on USG but detected on computed tomography urogram (CTU). A total of 201 patients' USG and CTU were compared retrospectively for the presence of calculi. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of USG were calculated with CTU as the gold standard. From the 201 sets of data collected, 59 calculi were detected on both USG and CTU. The sensitivity and specificity of renal calculi detection on USG were 53% and 85% respectively. The mean size of the renal calculus detected on USG was 7.6 mm ± 4.1 mm and the mean size of the renal calculus not visualised on USG but detected on CTU was 4 mm ± 2.4 mm. The sensitivity and specificity of ureteric calculi detection on USG were 12% and 97% respectively. The sensitivity and specificity of urinary bladder calculi detection on USG were 20% and 100% respectively. This study showed that the accuracy of US in detecting renal, ureteric and urinary bladder calculi were 67%, 80% and 98% respectively.
Prediction of Drug-Plasma Protein Binding Using Artificial Intelligence Based Algorithms.
Kumar, Rajnish; Sharma, Anju; Siddiqui, Mohammed Haris; Tiwari, Rajesh Kumar
2018-01-01
Plasma protein binding (PPB) has vital importance in the characterization of drug distribution in the systemic circulation. Unfavorable PPB can pose a negative effect on clinical development of promising drug candidates. The drug distribution properties should be considered at the initial phases of the drug design and development. Therefore, PPB prediction models are receiving an increased attention. In the current study, we present a systematic approach using Support vector machine, Artificial neural network, k- nearest neighbor, Probabilistic neural network, Partial least square and Linear discriminant analysis to relate various in vitro and in silico molecular descriptors to a diverse dataset of 736 drugs/drug-like compounds. The overall accuracy of Support vector machine with Radial basis function kernel came out to be comparatively better than the rest of the applied algorithms. The training set accuracy, validation set accuracy, precision, sensitivity, specificity and F1 score for the Suprort vector machine was found to be 89.73%, 89.97%, 92.56%, 87.26%, 91.97% and 0.898, respectively. This model can potentially be useful in screening of relevant drug candidates at the preliminary stages of drug design and development. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Montreal Cognitive Assessment (MoCA): validation study for frontotemporal dementia.
Freitas, Sandra; Simões, Mário R; Alves, Lara; Duro, Diana; Santana, Isabel
2012-09-01
The Montreal Cognitive Assessment (MoCA) is a brief instrument developed for the screening of milder forms of cognitive impairment, having surpassed the well-known limitations of the Mini-Mental State Examination (MMSE). The aim of the present study was to validate the MoCA as a cognitive screening test for behavioral-variant frontotemporal dementia (bv-FTD) by examining its psychometric properties and diagnostic accuracy. Three matched subgroups of participants were considered: bv-FTD (n = 50), Alzheimer disease (n = 50), and a control group of healthy adults (n = 50). Compared with the MMSE, the MoCA demonstrated consistently superior psychometric properties and discriminant capacity, providing comprehensive information about the patients' cognitive profiles. The diagnostic accuracy of MoCA for bv-FTD was extremely high (area under the curve AUC [MoCA] = 0.934, 95% confidence interval [CI] = 0.866-.974; AUC [MMSE] = 0.772, 95% CI = 0.677-0.850). With a cutoff below 17 points, the MoCA results for sensitivity, specificity, positive predictive value, negative predictive value, and classification accuracy were significantly superior to those of the MMSE. The MoCA is a sensitive and accurate instrument for screening the patients with bv-FTD and represents a better option than the MMSE.
Diagnostic value of computed tomography in dogs with chronic nasal disease.
Saunders, Jimmy H; van Bree, Henri; Gielen, Ingrid; de Rooster, Hilde
2003-01-01
Computed tomographic (CT) studies of 80 dogs with chronic nasal disease (nasal neoplasia (n = 19), nasal aspergillosis (n = 46), nonspecific rhinitis (n = 11), and foreign body rhinitis (n = 4)) were reviewed retrospectively by two independent observers. Each observer filled out a custom-designed list to record his or her interpretation of the CT signs and selected a diagnosis. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the diagnosis of each disease. The agreement between observers was evaluated. The CT signs corresponded to those previously described in the literature. CT had an accuracy greater than 90% for each observer in all disease processes. The sensitivity, specificity, PPV, and NPV were greater than 80% in all dogs with the exception of the PPV of foreign body rhinitis (80% for observer A and 44% for observer B). There was a substantial, to almost perfect, agreement between the two observers regarding the CT signs and diagnosis. This study indicates a high accuracy of CT for diagnosis of dogs with chronic nasal disease. The differentiation between nasal aspergillosis restricted to the nasal passages and foreign body rhinitis may be difficult when the foreign body is not visible.
Meinel, Felix G; Schoepf, U Joseph; Townsend, Jacob C; Flowers, Brian A; Geyer, Lucas L; Ebersberger, Ullrich; Krazinski, Aleksander W; Kunz, Wolfgang G; Thierfelder, Kolja M; Baker, Deborah W; Khan, Ashan M; Fernandes, Valerian L; O'Brien, Terrence X
2018-06-15
We aimed to determine the diagnostic yield and accuracy of coronary CT angiography (CCTA) in patients referred for invasive coronary angiography (ICA) based on clinical concern for coronary artery disease (CAD) and an abnormal nuclear stress myocardial perfusion imaging (MPI) study. We enrolled 100 patients (84 male, mean age 59.6 ± 8.9 years) with an abnormal MPI study and subsequent referral for ICA. Each patient underwent CCTA prior to ICA. We analyzed the prevalence of potentially obstructive CAD (≥50% stenosis) on CCTA and calculated the diagnostic accuracy of ≥50% stenosis on CCTA for the detection of clinically significant CAD on ICA (defined as any ≥70% stenosis or ≥50% left main stenosis). On CCTA, 54 patients had at least one ≥50% stenosis. With ICA, 45 patients demonstrated clinically significant CAD. A positive CCTA had 100% sensitivity and 84% specificity with a 100% negative predictive value and 83% positive predictive value for clinically significant CAD on a per patient basis in MPI positive symptomatic patients. In conclusion, almost half (48%) of patients with suspected CAD and an abnormal MPI study demonstrate no obstructive CAD on CCTA.
Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy
NASA Astrophysics Data System (ADS)
Delyuzar; Amir, Z.; Suryadi, D.
2018-03-01
Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.
Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed
2013-01-01
Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394
The accuracy of transvaginal sonography to detect endometriosis cyst
NASA Astrophysics Data System (ADS)
Diantika, M.; Gunardi, E. R.
2017-08-01
Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.
Subjective global assessment of nutritional status in children.
Mahdavi, Aida Malek; Ostadrahimi, Alireza; Safaiyan, Abdolrasool
2010-10-01
This study was aimed to compare the subjective and objective nutritional assessments and to analyse the performance of subjective global assessment (SGA) of nutritional status in diagnosing undernutrition in paediatric patients. One hundred and forty children (aged 2-12 years) hospitalized consecutively in Tabriz Paediatric Hospital from June 2008 to August 2008 underwent subjective assessment using the SGA questionnaire and objective assessment, including anthropometric and biochemical measurements. Agreement between two assessment methods was analysed by the kappa (κ) statistic. Statistical indicators including (sensitivity, specificity, predictive values, error rates, accuracy, powers, likelihood ratios and odds ratio) between SGA and objective assessment method were determined. The overall prevalence of undernutrition according to the SGA (70.7%) was higher than that by objective assessment of nutritional status (48.5%). Agreement between the two evaluation methods was only fair to moderate (κ = 0.336, P < 0.001). The sensitivity, specificity, positive and negative predictive value of the SGA method for screening undernutrition in this population were 88.235%, 45.833%, 60.606% and 80.487%, respectively. Accuracy, positive and negative power of the SGA method were 66.428%, 56.074% and 41.25%, respectively. Likelihood ratio positive, likelihood ratio negative and odds ratio of the SGA method were 1.628, 0.256 and 6.359, respectively. Our findings indicated that in assessing nutritional status of children, there is not a good level of agreement between SGA and objective nutritional assessment. In addition, SGA is a highly sensitive tool for assessing nutritional status and could identify children at risk of developing undernutrition. © 2009 Blackwell Publishing Ltd.
Hwang, Hamish; Marsh, Ian; Doyle, Jason
2014-01-01
Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607
Food allergy in infants and children: clinical evaluation and management.
Levy, Y; Kornbroth, B; Ofer, I; Garty, B Z; Danon, Y L
1994-12-01
A total of 122 infants and children up to age 17 (69 males and 53 females) who were referred for food allergy to the Pediatric Allergy and Clinical Immunology Unit were evaluated by complete history, emphasizing the implicated foods, clinical presentation and involvement of various organ systems, physical examination, and prick skin tests to food allergens. Fourteen infants with a history of egg white allergy and positive skin tests to egg white also underwent skin tests (prick and intradermal in 1:100 dilution) to measles-mumps-rubella (MMR) vaccine; 35 children under 3 years old had 41 oral challenges with the suspected foods; and 9 children over 3 years old had 12 oral challenges with the suspected foods. We found that cow milk/humanized milk formula, egg white, soybean, and peanut are the main allergenic foods in the pediatric population. Thirteen children had 13 positive oral challenges: 12 to cow milk/humanized milk formula and one to egg white. Symptoms reproduced by oral challenges included urticarial and erythematous rash, conjunctival itching, angioedema, abdominal pain, vomiting, diarrhea, and rhinorrhea. No anaphylactic shock was reported. Negative skin test has an excellent predictive accuracy for negative oral challenge with the suspected food in children > 3 years old. The negative predictive accuracy of cow milk skin test in children < 3 years was 73%. Positive skin test is not a good predictor of a clinical reaction to food. Oral food challenge performed cautiously in a medical setting is the "gold standard" for diagnosis. MMR vaccine can be safely administered to infants with egg white allergy after skin tests with the vaccine are performed.
Sviklāne, Laura; Olmane, Evija; Dzērve, Zane; Kupčs, Kārlis; Pīrāgs, Valdis; Sokolovska, Jeļizaveta
2018-01-01
Little is known about the diagnostic value of hepatic steatosis index (HSI) and fatty liver index (FLI), as well as their link to metabolic syndrome in type 1 diabetes mellitus. We have screened the effectiveness of FLI and HSI in an observational pilot study of 40 patients with type 1 diabetes. FLI and HSI were calculated for 201 patients with type 1 diabetes. Forty patients with FLI/HSI values corresponding to different risk of liver steatosis were invited for liver magnetic resonance study. In-phase/opposed-phase technique of magnetic resonance was used. Accuracy of indices was assessed from the area under the receiver operating characteristic curve. Twelve (30.0%) patients had liver steatosis. For FLI, sensitivity was 90%; specificity, 74%; positive likelihood ratio, 3.46; negative likelihood ratio, 0.14; positive predictive value, 0.64; and negative predictive value, 0.93. For HSI, sensitivity was 86%; specificity, 66%; positive likelihood ratio, 1.95; negative likelihood ratio, 0.21; positive predictive value, 0.50; and negative predictive value, 0.92. Area under the receiver operating characteristic curve for FLI was 0.86 (95% confidence interval [0.72; 0.99]); for HSI 0.75 [0.58; 0.91]. Liver fat correlated with liver enzymes, waist circumference, triglycerides, and C-reactive protein. FLI correlated with C-reactive protein, liver enzymes, and blood pressure. HSI correlated with waist circumference and C-reactive protein. FLI ≥ 60 and HSI ≥ 36 were significantly associated with metabolic syndrome and nephropathy. The tested indices, especially FLI, can serve as surrogate markers for liver fat content and metabolic syndrome in type 1 diabetes. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Perez, Veronica B; Woods, Scott W; Roach, Brian J; Ford, Judith M; McGlashan, Thomas H; Srihari, Vinod H; Mathalon, Daniel H
2014-03-15
Only about one third of patients at high risk for psychosis based on current clinical criteria convert to a psychotic disorder within a 2.5-year follow-up period. Targeting clinical high-risk (CHR) individuals for preventive interventions could expose many to unnecessary treatments, underscoring the need to enhance predictive accuracy with nonclinical measures. Candidate measures include event-related potential components with established sensitivity to schizophrenia. Here, we examined the mismatch negativity (MMN) component of the event-related potential elicited automatically by auditory deviance in CHR and early illness schizophrenia (ESZ) patients. We also examined whether MMN predicted subsequent conversion to psychosis in CHR patients. Mismatch negativity to auditory deviants (duration, frequency, and duration + frequency double deviant) was assessed in 44 healthy control subjects, 19 ESZ, and 38 CHR patients. Within CHR patients, 15 converters to psychosis were compared with 16 nonconverters with at least 12 months of clinical follow-up. Hierarchical Cox regression examined the ability of MMN to predict time to psychosis onset in CHR patients. Irrespective of deviant type, MMN was significantly reduced in ESZ and CHR patients relative to healthy control subjects and in CHR converters relative to nonconverters. Mismatch negativity did not significantly differentiate ESZ and CHR patients. The duration + frequency double deviant MMN, but not the single deviant MMNs, significantly predicted the time to psychosis onset in CHR patients. Neurophysiological mechanisms underlying automatic processing of auditory deviance, as reflected by the duration + frequency double deviant MMN, are compromised before psychosis onset and can enhance the prediction of psychosis risk among CHR patients. Copyright © 2014 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Wong, Kenneth Pak Leung; Han, Audrey XinYun; Wong, Jeannie Leh Ying; Lee, Dave Yee Han
2017-02-01
The accuracy of magnetic resonance (MR) imaging in assessing meniscal and cartilage injuries in anterior cruciate ligament (ACL)-deficient knees as compared to arthroscopy was evaluated in the present study. The results of all preoperative MR imaging performed within 3 months prior to the ACL reconstruction were compared against intraoperative arthroscopic findings. A total of 206 patients were identified. The location and type of meniscal injuries as well as the location and grade of the cartilage injuries were studied. The negative predictive value, positive predictive value, sensitivity, specificity and accuracy of MR imaging for these 206 cases were calculated and analysed. In patients with an ACL injury, the highest incidence of concomitant injury was that of medial meniscus tears, 124 (60.2 %), followed by lateral meniscus tears, 105 (51.0 %), and cartilage injuries, 66 (32.0 %). Twenty-three (11.2 %) patients sustained injuries to all of the previously named structures. MR imaging was most accurate in detecting medial meniscus tears (85.9 %). MR imaging for medial meniscus tears also had the highest sensitivity (88.0 %) and positive predictive value (88.7 %), while MR imaging for cartilage injuries had the largest specificity (84.1 %) and negative predictive value (87.1 %). It was least accurate in evaluating lateral meniscus tears (74.3 %). The diagnostic accuracy of medial meniscus imaging is significantly influenced by age and the presence of lateral meniscus tears, while the duration between MR imaging and surgery has greater impact on the likelihood of lateral meniscus and cartilage injuries actually being present during surgery. The majority of meniscus tears missed by MR imaging affected the posterior horn and were complex in nature. Cartilage injuries affecting the medial femoral condyle or medial patella facet were also often missed by MR imaging. MR imaging remains a reliable tool for assessing meniscus tears and cartilage defects preoperatively. It is most accurate when evaluating medial meniscus tears. However, MR imaging should be used with discretion especially if there is a high index of suspicion of lateral meniscus tears. IV.
Malik, Muhammad Usman; Connelly, Tara M; Awan, Faisal; Pretorius, Frederik; Fiuza-Castineira, Constantino; El Faedy, Osama; Balfe, Paul
2017-04-01
The definitive diagnosis of acute appendicitis (AA) requires histopathological examination. Various clinical diagnostic scoring systems attempt to reduce negative appendectomy rates. The most commonly used in Western Europe and the USA is the Alvarado score. The Raja Isteri Pengiran Anak Saleha appendicitis (RIPASA) score achieves better sensitivity and specificity in Asian and Middle Eastern populations. We aimed to determine the diagnostic accuracy of the RIPASA score in Irish patients with AA. All patients who presented to our institution with right iliac fossa pain and clinically suspected AA between January 1 and December 31, 2015, were indentified from our hospital inpatient enquiry database and retrospectively studied. Operating theatre records and histology reports confirmed those who underwent a non-elective operative procedure and the presence or absence of AA. SPSS version 22 was used for statistical analysis. Standard deviation is provided where appropriate. Two hundred eight patients were included in the study (106/51% male, mean age 22.7 ± 9.2 years). One hundred thirty-five (64.9%) had histologically confirmed AA (mean symptom duration = 36.19 ± 15.90 h). At a score ≥7.5, the previously determined score most likely associated with AA in Eastern populations, the RIPASA scoring system demonstrated a sensitivity of 85.39%, specificity of 69.86%, positive predictive value of 84.06%, negative predictive value of 72.86% and diagnostic accuracy of 80% in our cohort. The RIPASA score is a useful tool to aid in the diagnosis of acute appendicitis in the Irish population. A score of ≥7.5 provides sensitivity and specificity exceeding that previously documented for the Alvarado score in Western populations. WHAT DOES THIS PAPER ADD TO THE LITERATURE?: This is the first study evaluating the utility of the RIPASA score in predicting acute appendicitis in a Western population. At a value of 7.5, a cut-off score suggestive of appendicitis in the Eastern population, RIPASA demonstrated a high-sensitivity, specificity, positive predictive value and diagnostic accuracy in our cohort and was more accurate than the commonly used Alvarado score.
Agetsuma, H.; Hirai, M.; Hirayama, H.; Suzuki, A.; Takanaka, C.; Yabe, S.; Inagaki, H.; Takatsu, F.; Hayashi, H.; Saito, H.
1996-01-01
OBJECTIVE: To investigate the value of a giant negative T wave (> or = 1.0 mV) in precordial leads of 12-lead electrocardiograms in the acute phase of Q wave myocardial infarction as a predictor of myocardial salvage. METHODS: Coronary angiographic and electrocardiographic findings, left ventricular ejection fraction in the chronic stage, and levels of cardiac enzymes were compared in patients with myocardial infarction with (group GNT, n = 31) and without (group N, n = 20) a giant negative T wave. GNT patients were divided into two subgroups according to the presence (GNT:R[+], n = 10) or absence (GNT: R[-], n = 21) of R wave recovery with an amplitude > or = 0.1 mV in at least one lead that had shown Q waves. RESULTS: The maximum level of creatine kinase and the total creatine kinase were lower in group GNT compared with group N (P < 0.05). The left ventricular ejection fraction was higher in group GNT than in group N (P < 0.05). The maximum creatine kinase and total creatine kinase were lower in GNT:R(+) than in GNT:R(-) (P < 0.01). The left ventricular ejection fraction was higher in GNT:R(+) than in GNT:R(-) (P < 0.01). The frequency of R wave recovery was significantly higher when giant negative T waves appeared within 100 h of myocardial infarction or when the maximum potential was > or = 1.4 mV. The appearance of a giant negative T wave > or = 1.4 mV had a sensitivity of 90%, a specificity of 71.4%, a diagnostic accuracy of 77.4%, a positive predictive value of 60%, and a negative predictive value of 93.8% for prediction of R wave recovery. CONCLUSIONS: The appearance of a giant negative T wave, especially within 100 h of the onset of myocardial infarction, with a maximum potential of > or = 1.4 mV, may predict a reappearance of the R wave and a better left ventricular function in patients in the chronic stage of anterior myocardial infarction. PMID:8800983
Common polygenic variation enhances risk prediction for Alzheimer's disease.
Escott-Price, Valentina; Sims, Rebecca; Bannister, Christian; Harold, Denise; Vronskaya, Maria; Majounie, Elisa; Badarinarayan, Nandini; Morgan, Kevin; Passmore, Peter; Holmes, Clive; Powell, John; Brayne, Carol; Gill, Michael; Mead, Simon; Goate, Alison; Cruchaga, Carlos; Lambert, Jean-Charles; van Duijn, Cornelia; Maier, Wolfgang; Ramirez, Alfredo; Holmans, Peter; Jones, Lesley; Hardy, John; Seshadri, Sudha; Schellenberg, Gerard D; Amouyel, Philippe; Williams, Julie
2015-12-01
The identification of subjects at high risk for Alzheimer's disease is important for prognosis and early intervention. We investigated the polygenic architecture of Alzheimer's disease and the accuracy of Alzheimer's disease prediction models, including and excluding the polygenic component in the model. This study used genotype data from the powerful dataset comprising 17 008 cases and 37 154 controls obtained from the International Genomics of Alzheimer's Project (IGAP). Polygenic score analysis tested whether the alleles identified to associate with disease in one sample set were significantly enriched in the cases relative to the controls in an independent sample. The disease prediction accuracy was investigated in a subset of the IGAP data, a sample of 3049 cases and 1554 controls (for whom APOE genotype data were available) by means of sensitivity, specificity, area under the receiver operating characteristic curve (AUC) and positive and negative predictive values. We observed significant evidence for a polygenic component enriched in Alzheimer's disease (P = 4.9 × 10(-26)). This enrichment remained significant after APOE and other genome-wide associated regions were excluded (P = 3.4 × 10(-19)). The best prediction accuracy AUC = 78.2% (95% confidence interval 77-80%) was achieved by a logistic regression model with APOE, the polygenic score, sex and age as predictors. In conclusion, Alzheimer's disease has a significant polygenic component, which has predictive utility for Alzheimer's disease risk and could be a valuable research tool complementing experimental designs, including preventative clinical trials, stem cell selection and high/low risk clinical studies. In modelling a range of sample disease prevalences, we found that polygenic scores almost doubles case prediction from chance with increased prediction at polygenic extremes. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chara, Liaskou; Eleftherios, Vouzounerakis; Maria, Moirasgenti; Anastasia, Trikoupi; Chryssoula, Staikou
2014-01-01
Background and Aims: Difficult airway assessment is based on various anatomic parameters of upper airway, much of it being concentrated on oral cavity and the pharyngeal structures. The diagnostic value of tests based on neck anatomy in predicting difficult laryngoscopy was assessed in this prospective, open cohort study. Methods: We studied 341 adult patients scheduled to receive general anaesthesia. Thyromental distance (TMD), sternomental distance (STMD), ratio of height to thyromental distance (RHTMD) and neck circumference (NC) were measured pre-operatively. The laryngoscopic view was classified according to the Cormack–Lehane Grade (1-4). Difficult laryngoscopy was defined as Cormack–Lehane Grade 3 or 4. The optimal cut-off points for each variable were identified by using receiver operating characteristic analysis. Sensitivity, specificity and positive predictive value and negative predictive value (NPV) were calculated for each test. Multivariate analysis with logistic regression, including all variables, was used to create a predictive model. Comparisons between genders were also performed. Results: Laryngoscopy was difficult in 12.6% of the patients. The cut-off values were: TMD ≤7 cm, STMD ≤15 cm, RHTMD >18.4 and NC >37.5 cm. The RHTMD had the highest sensitivity (88.4%) and NPV (95.2%), while TMD had the highest specificity (83.9%). The area under curve (AUC) for the TMD, STMD, RHTMD and NC was 0.63, 0.64, 0.62 and 0.54, respectively. The predictive model exhibited a higher and statistically significant diagnostic accuracy (AUC: 0.68, P < 0.001). Gender-specific cut-off points improved the predictive accuracy of NC in women (AUC: 0.65). Conclusions: The TMD, STMD, RHTMD and NC were found to be poor single predictors of difficult laryngoscopy, while a model including all four variables had a significant predictive accuracy. Among the studied tests, gender-specific cut-off points should be used for NC. PMID:24963183
Liaskou, Chara; Chara, Liaskou; Vouzounerakis, Eleftherios; Eleftherios, Vouzounerakis; Moirasgenti, Maria; Maria, Moirasgenti; Trikoupi, Anastasia; Anastasia, Trikoupi; Staikou, Chryssoula; Chryssoula, Staikou
2014-03-01
Difficult airway assessment is based on various anatomic parameters of upper airway, much of it being concentrated on oral cavity and the pharyngeal structures. The diagnostic value of tests based on neck anatomy in predicting difficult laryngoscopy was assessed in this prospective, open cohort study. We studied 341 adult patients scheduled to receive general anaesthesia. Thyromental distance (TMD), sternomental distance (STMD), ratio of height to thyromental distance (RHTMD) and neck circumference (NC) were measured pre-operatively. The laryngoscopic view was classified according to the Cormack-Lehane Grade (1-4). Difficult laryngoscopy was defined as Cormack-Lehane Grade 3 or 4. The optimal cut-off points for each variable were identified by using receiver operating characteristic analysis. Sensitivity, specificity and positive predictive value and negative predictive value (NPV) were calculated for each test. Multivariate analysis with logistic regression, including all variables, was used to create a predictive model. Comparisons between genders were also performed. Laryngoscopy was difficult in 12.6% of the patients. The cut-off values were: TMD ≤7 cm, STMD ≤15 cm, RHTMD >18.4 and NC >37.5 cm. The RHTMD had the highest sensitivity (88.4%) and NPV (95.2%), while TMD had the highest specificity (83.9%). The area under curve (AUC) for the TMD, STMD, RHTMD and NC was 0.63, 0.64, 0.62 and 0.54, respectively. The predictive model exhibited a higher and statistically significant diagnostic accuracy (AUC: 0.68, P < 0.001). Gender-specific cut-off points improved the predictive accuracy of NC in women (AUC: 0.65). The TMD, STMD, RHTMD and NC were found to be poor single predictors of difficult laryngoscopy, while a model including all four variables had a significant predictive accuracy. Among the studied tests, gender-specific cut-off points should be used for NC.
Diagnostic accuracy of fluorescence microlymphography for detecting limb lymphedema.
Keo, H H; Husmann, M; Groechenig, E; Willenberg, T; Gretener, S B
2015-04-01
Fluorescence microlymphography (FML) is a minimally invasive technique for visualization of the cutaneous lymphatic network. The aim of the study was to assess the accuracy and safety of FML in patients with unilateral lymphedema. This was a cross sectional study. Patients with unilateral leg swelling were assessed and compared with the unaffected contralateral limb. FML was performed in all index legs and the contralateral leg by injecting 0.1 mL of fluorescein isothiocyanate (FITC)-labeled dextran intradermally in both limbs at the same level. The most prominent swelling of the affected limb was the anatomical reference. The spread of the dye in the lymphatic capillaries of the skin was measured in all dimensions by epiluminator intravital microscopy and the maximum dye spread value 10 min after injection was used for statistical analysis. The contralateral leg served as control. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess threshold values that best predict lymphedema. Between March 2008 and February 2014 seventy patients with unilateral chronic leg swelling were clinically diagnosed with lymphedema. The median age was 45 (IQR 27-56) years. Of those, 46 (65.7%) were female and 71.4% had primary and 28.6% secondary lymphedema. Sensitivity, specificity, positive and negative likelihood ratio, and positive and negative predictive value were 94.3%, 78.6%, 4.40, 0.07, 81.5%, and 93.2% for the 12 mm cut off level and 91.4%, 85.7%, 6.40, 0.10, 86.5%, and 90.9% for the 14 mm cut off level, respectively. The area under the ROC curve was 0.89 (95% CI: 0.83-0.95). No major adverse events were observed. FML is an almost atraumatic and safe technique for detecting lymphedema in patients with leg swelling. In this series the greatest accuracy was observed at a cut off level of ≥14 mm maximum spread. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
A systematic review of screening questionnaires for childhood lead poisoning.
Ossiander, Eric M
2013-01-01
The Centers for Disease Control and Prevention encourages the use of risk factor questionnaires to screen children for lead poisoning. A majority of state health departments have formal lead screening guidelines that recommend health care providers use questionnaires. We conducted a systematic review to evaluate the ability of lead screening questionnaires to predict lead poisoning risk among children. Articles that reported the evaluation of a predesigned lead screening questionnaire were obtained by searching Medline/PubMed and by examining references of articles obtained through the online search. From each evaluation, we abstracted the number of children that were true positive, false positive, true negative, and false negative, according to the results of the screening questionnaire and the follow-up blood lead test. From these data, we calculated specificity and sensitivity of the questionnaire for each evaluation. Twenty articles met the inclusion criteria: these included 28 separate questionnaire evaluations. Among 17 evaluations of the 1991 Centers for Disease Control and Prevention questionnaire, sensitivity ranged from 0.25 to 0.87, specificity from 0.31 to 0.80, and accuracy (sum of sensitivity and specificity) from 0.74 to 1.39. The pooled mean estimates for this questionnaire were sensitivity 0.61 (95% confidence interval: 0.53-0.68); specificity 0.52 (0.45-0.60); accuracy 1.12 (1.06-1.18). Among 11 evaluations of all other questionnaires, sensitivity ranged from 0.43 to 0.90, specificity from 0.17 to 0.66, and accuracy from 0.94 to 1.27. For these questionnaires, the pooled mean estimates were sensitivity 0.76 (0.68-0.85), specificity 0.41 (0.33-0.49), and accuracy 1.12 (1.06-1.18). Lead screening questionnaires showed a wide range of sensitivity and specificity and performed little better than chance at predicting lead poisoning risk among children.
Ritchie, Brianne M; Connors, Jean M; Sylvester, Katelyn W
2017-04-01
Previous studies have demonstrated optimized diagnostic accuracy in utilizing higher antiheparin-platelet factor 4 (PF4) enzyme-linked immunosorbent assay (ELISA) optical density (OD) thresholds for diagnosing heparin-induced thrombocytopenia (HIT). We describe the incidence of positive serotonin release assay (SRA) results, as well as performance characteristics, for antiheparin-PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units in the diagnosis of HIT at our institution. Following institutional review board approval, we conducted a single-center retrospective chart review on adult inpatients with a differential diagnosis of HIT evaluated by both antiheparin-PF4 ELISA and SRA from 2012 to 2014. The major endpoints were to assess incidence of positive SRA results, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy at antiheparin-PF4 ELISA values ≥0.4 OD units when compared to values ≥0.8 and ≥1.0 OD units. Clinical characteristics, including demographics, laboratory values, clinical and safety outcomes, length of stay, and mortality, were collected. A total of 140 patients with 140 antiheparin-PF4 ELISA and SRA values were evaluated, of which 23 patients were SRA positive (16.4%) and 117 patients were SRA negative (83.6%). We identified a sensitivity of 91.3% versus 82.6% and 73.9%, specificity of 61.5% versus 87.2% and 91.5%, PPV of 31.8% versus 55.9% and 63.0%, NPV of 97.3% versus 96.2% and 94.7%, and accuracy of 66.4% versus 86.4% and 88.6% at antiheparin-PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units, respectively. Our study suggests an increased antiheparin-PF4 ELISA threshold of 0.8 or 1.0 OD units enhances specificity, PPV, and accuracy while maintaining NPV with decreased sensitivity.
Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat
2017-06-01
To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Kanté, F; Belghiti, J; Roseau, G; Thomassin-Naggara, I; Bazot, M; Daraï, E; Ballester, M
2017-03-01
To compare the accuracy of magnetic resonance imaging (MRI) and rectal endoscopic sonography (RES) for the diagnosis of colorectal endometriosis. In retrospective study, 407 patients operated on service of gynecology of Tenon hospital for deep endometriosis with suspected colorectal involvement. All patients underwent MRI and then RES. In the study, 239 patients (59%) had colorectal endometriosis which were diagnosed with the histology. The sensitivity, specificity, positive and negative predictive value (PPV and NPV) of RES and MRI for the diagnosis of colorectal endometriosis were respectively 92%, 87%, 91%, 88% and 85%, 88%, 91%, 80%. The accuracy of RES was not significantly different than MRI (90% versus 86%, P=0.09). RES is a good exam to diagnose colorectal endometriosis. It is able to improve diagnosis performances. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Predicting drug-induced liver injury in human with Naïve Bayes classifier approach.
Zhang, Hui; Ding, Lan; Zou, Yi; Hu, Shui-Qing; Huang, Hai-Guo; Kong, Wei-Bao; Zhang, Ji
2016-10-01
Drug-induced liver injury (DILI) is one of the major safety concerns in drug development. Although various toxicological studies assessing DILI risk have been developed, these methods were not sufficient in predicting DILI in humans. Thus, developing new tools and approaches to better predict DILI risk in humans has become an important and urgent task. In this study, we aimed to develop a computational model for assessment of the DILI risk with using a larger scale human dataset and Naïve Bayes classifier. The established Naïve Bayes prediction model was evaluated by 5-fold cross validation and an external test set. For the training set, the overall prediction accuracy of the 5-fold cross validation was 94.0 %. The sensitivity, specificity, positive predictive value and negative predictive value were 97.1, 89.2, 93.5 and 95.1 %, respectively. The test set with the concordance of 72.6 %, sensitivity of 72.5 %, specificity of 72.7 %, positive predictive value of 80.4 %, negative predictive value of 63.2 %. Furthermore, some important molecular descriptors related to DILI risk and some toxic/non-toxic fragments were identified. Thus, we hope the prediction model established here would be employed for the assessment of human DILI risk, and the obtained molecular descriptors and substructures should be taken into consideration in the design of new candidate compounds to help medicinal chemists rationally select the chemicals with the best prospects to be effective and safe.
Assessing the accuracy of predictive models for numerical data: Not r nor r2, why not? Then what?
2017-01-01
Assessing the accuracy of predictive models is critical because predictive models have been increasingly used across various disciplines and predictive accuracy determines the quality of resultant predictions. Pearson product-moment correlation coefficient (r) and the coefficient of determination (r2) are among the most widely used measures for assessing predictive models for numerical data, although they are argued to be biased, insufficient and misleading. In this study, geometrical graphs were used to illustrate what were used in the calculation of r and r2 and simulations were used to demonstrate the behaviour of r and r2 and to compare three accuracy measures under various scenarios. Relevant confusions about r and r2, has been clarified. The calculation of r and r2 is not based on the differences between the predicted and observed values. The existing error measures suffer various limitations and are unable to tell the accuracy. Variance explained by predictive models based on cross-validation (VEcv) is free of these limitations and is a reliable accuracy measure. Legates and McCabe’s efficiency (E1) is also an alternative accuracy measure. The r and r2 do not measure the accuracy and are incorrect accuracy measures. The existing error measures suffer limitations. VEcv and E1 are recommended for assessing the accuracy. The applications of these accuracy measures would encourage accuracy-improved predictive models to be developed to generate predictions for evidence-informed decision-making. PMID:28837692
Sun, Yong-sheng; Lou, Si-quan; Wen, Jian-min; Lv, Wei-xin; Jiao, Chang-geng; Yang, Su-min; Xu, Hai-bin
2011-02-01
To assess the clinical value of polymerase chain reaction (PCR) in the diagnosis and differential diagnosis of joint tuberculosis (TB). PCR was used blindly to detect the DNA of Mycobacterium tuberculosis (M.TB) in five specimens of M.TB, 5 of BCG, and 10 of other bacteria. Then, M. TB in 98 samples from patients with joint TB and 100 samples from patients with non-tubercular joint disorders were detected by PCR, acid-fast staining and culture,. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PCR were calculated. The χ2 test was used for statistical analysis of the frequency of various factors. At the same time, some problems with PCR were also systematically analyzed. (1) In the "standard samples", both M. TB and BCG showed positive while other bacteria were negative. (2) In 98 cases from patients with joint TB, 81 were positive by PCR, 6 by acid-fast staining, and 17 by culture. In 100 cases from patients with non-tuberculous joint disorders, 9 were positive by PCR, and none by either acid-fast staining or culture. Sensitivity, specificity, accuracy, positive and negative predictive value of PCR were 82.65% (81/98), 91.00% (91/100), 86.87% (172/198), 90.00% (81/90) and 84.26% (91/108), respectively. (3) The positive rates for PCR, acid-fast staining and culture in detection of M. TB were 82.65% (81/98), 6.12% (6/98), and 17.34% (17/98), respectively. There were statistically significant differences between the three methods (P < 0.001). (4) The process of PCR is automatic, and can be completed within 3 to 6 hours, whereas 4 to 8 weeks are required for the conventional culture of M. TB. PCR is a sensitive, specific, rapid, simple and minimally invasive method for detection of M. TB in samples from joint TB, and can play an important role in early and rapid diagnosis and differential diagnosis of joint TB. But it also has some limitations, such as false positivity and false negativity. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.
Rady, Hanaa Ibrahim; Zekri, Hanan
2015-01-01
To assess children with myocarditis, the frequency of various presenting symptoms, and the accuracy of different investigations in the diagnosis. This was an observational study of 63 patients admitted to PICU with non-cardiac diagnosis. Cardiac enzymes, chest-X ray, echocardiography, and electrocardiogram were performed to diagnose myocarditis among those patients. There were 16 cases of definite myocarditis. The age distribution was non-normal, with median of 5.5 months (3.25-21). Of the 16 patients who were diagnosed with myocarditis, 62.5% were originally diagnosed as having respiratory problems, and there were more females than males. Among the present cases, the accuracy of cardiac enzymes (cardiac troponin T [cTn] and creatine phosphokinase MB [CKMB]) in the diagnosis of myocarditis was only 63.5%, while the accuracy of low fractional shortening and of chest-X ray cardiomegaly was 85.7 and 80.9%; respectively. Cardiac troponin folds 2.02 had positive predictive value of 100%, negative predictive value of 88.7%, specificity of 100%, sensitivity of 62.5%, and accuracy of 90.5%. Children with myocarditis present with symptoms that can be mistaken for other types of illnesses. When clinical suspicion of myocarditis exists, chest-X ray and echocardiography are sufficient as screening tests. Cardiac troponins confirm the diagnosis in screened cases, with specificity of 100%. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E
1994-01-01
The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359
Boulay, G; Francoz, D; Doré, E; Dufour, S; Veillette, M; Badillo, M; Bélanger, A-M; Buczinski, S
2014-01-01
The objectives of the current study were (1) to determine the gain in prognostic accuracy of preoperative l-lactate concentration (LAC) measured on farm on cows with right displaced abomasum (RDA) or abomasal volvulus (AV) for predicting negative outcome; and (2) to suggest clinically relevant thresholds for such use. A cohort of 102 cows with on-farm surgical diagnostic of RDA or AV was obtained from June 2009 through December 2011. Blood was drawn from coccygeal vessels before surgery and plasma LAC was immediately measured by using a portable clinical analyzer. Dairy producers were interviewed by phone 30 d following surgery and the outcome was determined: a positive outcome if the owner was satisfied of the overall evolution 30 d postoperatively, and a negative outcome if the cow was culled, died, or if the owner reported being unsatisfied 30 d postoperatively. The area under the curve of the receiver operating characteristic curve for LAC was 0.92 and was significantly greater than the area under the curve of the receiver operating characteristic curve of heart rate (HR; 0.77), indicating that LAC, in general, performed better than HR to predict a negative outcome. Furthermore, the ability to predict a negative outcome was significantly improved when LAC measurement was considered in addition to the already available HR data (area under the curve: 0.93 and 95% confidence interval: 0.87, 0.99). Important inflection points of the misclassification cost term function were noted at thresholds of 2 and 6 mmol/L, suggesting the potential utility of these cut-points. The 2 and 6 mmol/L thresholds had a sensitivity, specificity, positive predictive value, and negative predictive value for predicting a negative outcome of 76.2, 82.7, 53.3, and 93.1%, and of 28.6, 97.5, 75, and 84%, respectively. In terms of clinical interpretation, LAC ≤2 mmol/L appeared to be a good indicator of positive outcome and could be used to support a surgical treatment decision. The treatment decision for cows with LAC between 2 and 6 mmol/L, however, would depend on the economic context and the owner's attitude to risk in regard to potential return on its investment. Finally, performing a surgical correction on commercial cows with RDA or AV and a LAC ≥6 mmol/L appeared to be unjustified and these animals should be culled based on their high probability of negative outcome. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Haiducek, John D.; Welling, Daniel T.; Ganushkina, Natalia Y.; Morley, Steven K.; Ozturk, Dogacan Su
2017-12-01
We simulated the entire month of January 2005 using the Space Weather Modeling Framework (SWMF) with observed solar wind data as input. We conducted this simulation with and without an inner magnetosphere model and tested two different grid resolutions. We evaluated the model's accuracy in predicting Kp, SYM-H, AL, and cross-polar cap potential (CPCP). We find that the model does an excellent job of predicting the SYM-H index, with a root-mean-square error (RMSE) of 17-18 nT. Kp is predicted well during storm time conditions but overpredicted during quiet times by a margin of 1 to 1.7 Kp units. AL is predicted reasonably well on average, with an RMSE of 230-270 nT. However, the model reaches the largest negative AL values significantly less often than the observations. The model tended to overpredict CPCP, with RMSE values on the order of 46-48 kV. We found the results to be insensitive to grid resolution, with the exception of the rate of occurrence for strongly negative AL values. The use of the inner magnetosphere component, however, affected results significantly, with all quantities except CPCP improved notably when the inner magnetosphere model was on.
Low Expression of Mucin-4 Predicts Poor Prognosis in Patients With Clear-Cell Renal Cell Carcinoma
Fu, Hangcheng; Liu, Yidong; Xu, Le; Chang, Yuan; Zhou, Lin; Zhang, Weijuan; Yang, Yuanfeng; Xu, Jiejie
2016-01-01
Abstract Mucin-4 (MUC4), a member of membrane-bound mucins, has been reported to exert a large variety of distinctive roles in tumorigenesis of different cancers. MUC4 is aberrantly expressed in clear-cell renal cell carcinoma (ccRCC) but its prognostic value is still unveiled. This study aims to assess the clinical significance of MUC4 expression in patients with ccRCC. The expression of MUC4 was assessed by immunohistochemistry in 198 patients with ccRCC who underwent nephrectomy retrospectively in 2003 and 2004. Sixty-seven patients died before the last follow-up in the cohort. Kaplan–Meier method with log-rank test was applied to compare survival curves. Univariate and multivariate Cox regression models were applied to evaluate the prognostic value of MUC4 expression in overall survival (OS). The predictive nomogram was constructed based on the independent prognostic factors. The calibration was built to evaluate the predictive accuracy of nomogram. In patients with ccRCC, MUC4 expression, which was determined to be an independent prognostic indicator for OS (hazard ratio [HR] 3.891; P < 0.001), was negatively associated with tumor size (P = 0.036), Fuhrman grade (P = 0.044), and OS (P < 0.001). The prognostic accuracy of TNM stage, UCLA Integrated Scoring System (UISS), and Mayo clinic stage, size, grade, and necrosis score (SSIGN) prognostic models was improved when MUC4 expression was added. The independent prognostic factors, pT stage, distant metastases, Fuhrman grade, sarcomatoid, and MUC4 expression were integrated to establish a predictive nomogram with high predictive accuracy. MUC4 expression is an independent prognostic factor for OS in patients with ccRCC. PMID:27124015
Chen, Yile; Tai, Qiang; Hong, Shaodong; Kong, Yuan; Shang, Yushu; Liang, Wenhua; Guo, Zhiyong; He, Xiaoshun
2012-11-15
The question of whether high pretransplantation soluble CD30 (sCD30) level can be a predictor of kidney transplant acute rejection (AR) is under debate. Herein, we performed a meta-analysis on the predictive efficacy of sCD30 for AR in renal transplantation. PubMed (1966-2012), EMBASE (1988-2012), and Web of Science (1986-2012) databases were searched for studies concerning the predictive efficacy of sCD30 for AR after kidney transplantation. After a careful review of eligible studies, sensitivity, specificity, and other measures of the accuracy of sCD30 were pooled. A summary receiver operating characteristic curve was used to represent the overall test performance. Twelve studies enrolling 2507 patients met the inclusion criteria. The pooled estimates for pretransplantation sCD30 in prediction of allograft rejection risk were poor, with a sensitivity of 0.70 (95% confidence interval (CI), 0.66-0.74), a specificity of 0.48 (95% CI, 0.46-0.50), a positive likelihood ratio of 1.35 (95% CI, 1.20-1.53), a negative likelihood ratio of 0.68 (95% CI, 0.55-0.84), and a diagnostic odds ratio of 2.07 (95% CI, 1.54-2.80). The area under curve of the summary receiver operating characteristic curve was 0.60, indicating poor overall accuracy of the serum sCD30 level in the prediction of patients at risk for AR. The results of the meta-analysis show that the accuracy of pretransplantation sCD30 for predicting posttransplantation AR was poor. Prospective studies are needed to clarify the usefulness of this test for identifying risks of AR in transplant recipients.
Seymer, A; Keinrath, P; Holzmannhofer, J; Pirich, C; Hergan, K; Meissnitzer, M W
2015-01-01
Objective: To prospectively analyse the diagnostic value of semi-quantitative breast-specific gamma imaging (BSGI) in the work-up of suspicious breast lesions compared with that of mammography (MG), breast ultrasound and MRI of the breast. Methods: Within a 15-month period, 67 patients with 92 breast lesions rated as Category IV or V according to the breast imaging reporting and data system detected with MG and/or ultrasound were included into the study. After the injection of 740–1110 MBq of Technetium-99m (99mTc) SestaMIBI intravenously, scintigrams were obtained in two projections comparable to MG. The BSGI was analysed visually and semi-quantitatively by calculating a relative uptake factor (X). With the exception of two patients with cardiac pacemakers, all patients underwent 3-T breast MRI. Biopsy results were obtained as the reference standard in all patients. Sensitivity, specificity, positive- and negative-predictive values, accuracy and area under the curve were calculated for each modality. Results: Among the 92 lesions, 67 (72.8%) were malignant. 60 of the 67 cancers of any size were detected by BSGI with an overall sensitivity of 90%, only exceeded by ultrasound with a sensitivity of 99%. The sensitivity of BSGI for lesions <1 cm declined significantly to 60%. Overall specificity of ultrasound was only 20%. Specificity, accuracy and positive-predictive value were the highest for BSGI (56%, 80% and 85%, respectively). X was significantly higher for malignant lesions (mean, 4.27) and differed significantly between ductal types (mean, 4.53) and the other histopathological entities (mean, 3.12). Conclusion: Semi-quantitative BSGI with calculation of the relative uptake factor (X) can help to characterize breast lesions. BSGI negativity may obviate the need for biopsy of breast lesions >1 cm with low or intermediate prevalence for malignancy. Advances in knowledge: Compared with morphological imaging modalities, specificity, positive-predictive value for malignancy and accuracy were the highest for BSGI in our study. BSGI negativity may support the decision not to biopsy in selected lesions with a low or low-to-moderate pre-test probability for malignancy. PMID:25882690
[Identification of cervical lymph node micrometastasis of tongue cancer by color Doppler and MRI].
Fan, Sufeng; Zhang, Quan; Li, Qiuli; Wang, Lina; Zheng, Lie; Liu, Longzhong
2014-01-01
To assess the values of color Doppler and magnetic resonance imaging (MRI) in the identification of cervical lymph node micrometastasis of tongue cancer. Totally 96 cases of tongue cancer with impalpable neck lymph node was examined with color Doppler and MRI within one week before surgery. Chi-square test was used to assess if the presence of regional lymph node micrometastasis, histopathological analysis as a golden standard lymph node micrometastasis. For the diagnosis of cervical lymph node micrometastasis, color Doppler was significantly better than MRI in sensitivity (72.5% vs 50.0%, P = 0.039) and the accuracy (78.1% vs 64.6%, P = 0.038), but no significant difference in the specificity (82.1% vs 75.0%, P = 0.357), the positive predictive value (74.4% vs 58.8%, P = 0.159) and the negative predictive value (80.7% vs 67.7%, P = 0.108). Color Doppler is better than MRI in the sensitivity and accuracy for the diagnosis of cervical lymph node micrometastasis of tongue cancer.
Plasma neutrophil gelatinase-associated lipocalin: a marker of acute pyelonephritis in children.
Kim, Byung Kwan; Yim, Hyung Eun; Yoo, Kee Hwan
2017-03-01
This study was designed to compare the diagnostic accuracy of plasma neutrophil gelatinase-associated lipocalin (NGAL) with procalcitonin (PCT), C-reactive protein (CRP), and white blood cells (WBCs) for predicting acute pyelonephritis (APN) in children with febrile urinary tract infections (UTIs). In total, 138 children with febrile UTIs (APN 59, lower UTI 79) were reviewed retrospectively. Levels of NGAL, PCT, CRP, and WBCs in blood were measured on admission. The diagnostic accuracy of the biomarkers was investigated. Independent predictors of APN were identified by multivariate logistic regression analysis. Receiver operating curve (ROC) analyses showed good diagnostic profiles of NGAL, PCT, CRP, and WBCs for identifying APN [area under the curve (AUC) 0.893, 0.855, 0.879, and 0.654, respectively]. However, multivariate analysis revealed only plasma NGAL level was an independent predictor of APN (P = 0.006). At the best cutoff values of all examined biomarkers for identifying APN, sensitivity (86 %), specificity (85 %), positive predictive value (81 %), and negative predictive value (89 %) of plasma NGAL levels were the highest. The optimal NGAL cutoff value was 117 ng/ml. The positive likelihood ratio [odds ratio (OR) 5.69, 95 % confidence interval (CI) 3.56-8.78], and negative likelihood ratio (OR 0.16, 95 % CI 0.08-0.29) of plasma NGAL for APN diagnosis also showed it seemed to be more accurate than serum PCT, CRP, and WBCs. Plasma NGAL can be more useful than serum PCT, CRP, and WBC levels for identifying APN in children with febrile UTIs.
Solari, Lely; Soto, Alonso; Van der Stuyft, Patrick
2017-10-01
Diagnosis of pleural tuberculosis (PT) is still a challenge, particularly in resource-constrained settings. Alternative diagnostic tools are needed. We aimed at evaluating the utility of Clinical Prediction Rules (CPRs) for diagnosis of pleural tuberculosis in Peru. We identified CPRs for diagnosis of PT through a structured literature search. CPRs using high-complexity tests, as defined by the FDA, were excluded. We applied the identified CPRs to patients with pleural exudates attending two third-level hospitals in Lima, Peru, a setting with high incidence of tuberculosis. Besides pleural fluid analysis, patients underwent closed pleural biopsy for reaching a final diagnosis through combining microbiological and histopathological criteria. We evaluated the performance of the CPRs against this composite reference standard using classic indicators of diagnostic test validity. We found 15 eligible CPRs, of which 12 could be validated. Most included ADA, age, lymphocyte proportion and protein in pleural fluid as predictive findings. A total of 259 patients were included for their validation, of which 176 (67%) had PT and 50 (19%) malignant pleural effusion. The overall accuracy of the CPRs varied from 41% to 86%. Two had a positive likelihood ratio (LR) above 10, but none a negative LR below 0.1. ADA alone at a cut-off of ≥40 IU attained 87% diagnostic accuracy and had a positive LR of 6.6 and a negative LR of 0.2. Many CPRs for PT are available. In addition to ADA alone, none of them contributes significantly to diagnosis of PT. © 2017 John Wiley & Sons Ltd.
De Dominicis, F; Fourdrain, A; Iquille, J; Toublanc, B; François, G; Basille, D; Monconduit, J; Merlusca, G; Jounieaux, V; Andrejak, C; Berna, P
2015-08-01
We studied the non-surgical invasive staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and we detailed the differences of our series, in order to understand the criteria allowing to achieve a better performance. Retrospective observational study conducted between 2007 and 2011, including all patients with proven NSCLC who underwent EBUS-TBNA. For the 92 EBUS-TBNA performed, we found a sensitivity of 78%, a specificity of 93%, a positive predictive value (PPV) of 98%, a negative predictive value (NPV) of 45%, an accuracy of 80% and a prevalence of lymph node involvement at 84%. A learning curve has been demonstrated and a significant difference was found based on the number of punctures by procedure (P=0.02) or on histological type (P=0.02). By analyzing the data of the literature, we have been able to demonstrate that the accuracy and the negative predictive value are correlated with the prevalence. If we take into account this correlation, we can consider the results of our study close to those of the literature. We highlighted a number of criteria that will influence the diagnostic yield of EBUS-TBNA. While some have already been described, other criteria such as histological type or patient selection criteria are less discussed. The key point is the correlation between the prevalence and EBUS-TBNA results. Results of the assessment of lymph node involvement techniques should be interpreted according to the prevalence of lymph node involvement. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Elías, María Jesús Pérez; Gómez-Ayerbe, Cristina; Elías, Pilar Pérez; Muriel, Alfonso; de Santiago, Alberto Diaz; Martinez-Colubi, María; Moreno, Ana; Santos, Cristina; Polo, Lidia; Barea, Rafa; Robledillo, Gema; Uranga, Almudena; Espín, Agustina Cano; Quereda, Carmen; Dronda, Fernando; Casado, Jose Luis; Moreno, Santiago
2016-02-01
The aim of our study was to develop a Spanish-structured HIV risk of exposure and indicator conditions (RE&IC) questionnaire. People attending to an emergency room or to a primary clinical care center were offered to participate in a prospective, 1 arm, open label study, in which all enrolled patients filled out our developed questionnaire and were HIV tested. Questionnaire accuracy, feasibility, and reliability were evaluated.Valid paired 5329 HIV RE&IC questionnaire and rapid HIV tests were performed, 69.3% in the primary clinical care center, 49.6% women, median age 37 years old, 74.9% Spaniards, 20.1% Latin-Americans. Confirmed hidden HIV infection was detected in 4.1%, while HIV RE&IC questionnaire was positive in 51.2%. HIV RE&IC questionnaire sensitivity was 100% to predict HIV infection, with a 100% negative predictive value. When considered separately, RE or IC items sensitivity decreases to 86.4% or 91%, and similarly their negative predictive value to 99.9% for both of them. The majority of people studied, 90.8% self-completed HIV RE&IC questionnaire. Median time to complete was 3 minutes. Overall HIV RE&IC questionnaire test-retest Kappa agreement was 0.82 (almost perfect), likewise for IC items 0.89, while for RE items was lower 0.78 (substantial).A feasible and reliable Spanish HIV RE&IC self questionnaire accurately discriminated all non-HIV-infected people without missing any HIV diagnoses, in a low prevalence HIV infection area. The best accuracy and reliability were obtained when combining HIV RE&IC items.
Elías, María Jesús Pérez; Gómez-Ayerbe, Cristina; Elías, Pilar Pérez; Muriel, Alfonso; de Santiago, Alberto Diaz; Martinez-Colubi, María; Moreno, Ana; Santos, Cristina; Polo, Lidia; Barea, Rafa; Robledillo, Gema; Uranga, Almudena; Espín, Agustina Cano; Quereda, Carmen; Dronda, Fernando; Casado, Jose Luis; Moreno, Santiago
2016-01-01
Abstract The aim of our study was to develop a Spanish-structured HIV risk of exposure and indicator conditions (RE&IC) questionnaire. People attending to an emergency room or to a primary clinical care center were offered to participate in a prospective, 1 arm, open label study, in which all enrolled patients filled out our developed questionnaire and were HIV tested. Questionnaire accuracy, feasibility, and reliability were evaluated. Valid paired 5329 HIV RE&IC questionnaire and rapid HIV tests were performed, 69.3% in the primary clinical care center, 49.6% women, median age 37 years old, 74.9% Spaniards, 20.1% Latin-Americans. Confirmed hidden HIV infection was detected in 4.1%, while HIV RE&IC questionnaire was positive in 51.2%. HIV RE&IC questionnaire sensitivity was 100% to predict HIV infection, with a 100% negative predictive value. When considered separately, RE or IC items sensitivity decreases to 86.4% or 91%, and similarly their negative predictive value to 99.9% for both of them. The majority of people studied, 90.8% self-completed HIV RE&IC questionnaire. Median time to complete was 3 minutes. Overall HIV RE&IC questionnaire test-retest Kappa agreement was 0.82 (almost perfect), likewise for IC items 0.89, while for RE items was lower 0.78 (substantial). A feasible and reliable Spanish HIV RE&IC self questionnaire accurately discriminated all non–HIV-infected people without missing any HIV diagnoses, in a low prevalence HIV infection area. The best accuracy and reliability were obtained when combining HIV RE&IC items. PMID:26844471
McConville, Anna; Law, Bradley S.; Mahony, Michael J.
2013-01-01
Habitat modelling and predictive mapping are important tools for conservation planning, particularly for lesser known species such as many insectivorous bats. However, the scale at which modelling is undertaken can affect the predictive accuracy and restrict the use of the model at different scales. We assessed the validity of existing regional-scale habitat models at a local-scale and contrasted the habitat use of two morphologically similar species with differing conservation status (Mormopterus norfolkensis and Mormopterus species 2). We used negative binomial generalised linear models created from indices of activity and environmental variables collected from systematic acoustic surveys. We found that habitat type (based on vegetation community) best explained activity of both species, which were more active in floodplain areas, with most foraging activity recorded in the freshwater wetland habitat type. The threatened M. norfolkensis avoided urban areas, which contrasts with M. species 2 which occurred frequently in urban bushland. We found that the broad habitat types predicted from local-scale models were generally consistent with those from regional-scale models. However, threshold-dependent accuracy measures indicated a poor fit and we advise caution be applied when using the regional models at a fine scale, particularly when the consequences of false negatives or positives are severe. Additionally, our study illustrates that habitat type classifications can be important predictors and we suggest they are more practical for conservation than complex combinations of raw variables, as they are easily communicated to land managers. PMID:23977296
THE PANC 3 SCORE PREDICTING SEVERITY OF ACUTE PANCREATITIS.
Beduschi, Murilo Gamba; Mello, André Luiz Parizi; VON-Mühlen, Bruno; Franzon, Orli
2016-03-01
About 20% of cases of acute pancreatitis progress to a severe form, leading to high mortality rates. Several studies suggested methods to identify patients that will progress more severely. However, most studies present problems when used on daily practice. To assess the efficacy of the PANC 3 score to predict acute pancreatitis severity and its relation to clinical outcome. Acute pancreatitis patients were assessed as to sex, age, body mass index (BMI), etiology of pancreatitis, intensive care need, length of stay, length of stay in intensive care unit and mortality. The PANC 3 score was determined within the first 24 hours after diagnosis and compared to acute pancreatitis grade of the Revised Atlanta classification. Out of 64 patients diagnosed with acute pancreatitis, 58 met the inclusion criteria. The PANC 3 score was positive in five cases (8.6%), pancreatitis progressed to a severe form in 10 cases (17.2%) and five patients (8.6%) died. Patients with a positive score and severe pancreatitis required intensive care more often, and stayed for a longer period in intensive care units. The PANC 3 score showed sensitivity of 50%, specificity of 100%, accuracy of 91.4%, positive predictive value of 100% and negative predictive value of 90.6% in prediction of severe acute pancreatitis. The PANC 3 score is useful to assess acute pancreatitis because it is easy and quick to use, has high specificity, high accuracy and high predictive value in prediction of severe acute pancreatitis.
THE PANC 3 SCORE PREDICTING SEVERITY OF ACUTE PANCREATITIS
BEDUSCHI, Murilo Gamba; MELLO, André Luiz Parizi; VON-MÜHLEN, Bruno; FRANZON, Orli
2016-01-01
Background : About 20% of cases of acute pancreatitis progress to a severe form, leading to high mortality rates. Several studies suggested methods to identify patients that will progress more severely. However, most studies present problems when used on daily practice. Objective : To assess the efficacy of the PANC 3 score to predict acute pancreatitis severity and its relation to clinical outcome. Methods : Acute pancreatitis patients were assessed as to sex, age, body mass index (BMI), etiology of pancreatitis, intensive care need, length of stay, length of stay in intensive care unit and mortality. The PANC 3 score was determined within the first 24 hours after diagnosis and compared to acute pancreatitis grade of the Revised Atlanta classification. Results : Out of 64 patients diagnosed with acute pancreatitis, 58 met the inclusion criteria. The PANC 3 score was positive in five cases (8.6%), pancreatitis progressed to a severe form in 10 cases (17.2%) and five patients (8.6%) died. Patients with a positive score and severe pancreatitis required intensive care more often, and stayed for a longer period in intensive care units. The PANC 3 score showed sensitivity of 50%, specificity of 100%, accuracy of 91.4%, positive predictive value of 100% and negative predictive value of 90.6% in prediction of severe acute pancreatitis. Conclusion : The PANC 3 score is useful to assess acute pancreatitis because it is easy and quick to use, has high specificity, high accuracy and high predictive value in prediction of severe acute pancreatitis. PMID:27120730
Cascaded bidirectional recurrent neural networks for protein secondary structure prediction.
Chen, Jinmiao; Chaudhari, Narendra
2007-01-01
Protein secondary structure (PSS) prediction is an important topic in bioinformatics. Our study on a large set of non-homologous proteins shows that long-range interactions commonly exist and negatively affect PSS prediction. Besides, we also reveal strong correlations between secondary structure (SS) elements. In order to take into account the long-range interactions and SS-SS correlations, we propose a novel prediction system based on cascaded bidirectional recurrent neural network (BRNN). We compare the cascaded BRNN against another two BRNN architectures, namely the original BRNN architecture used for speech recognition as well as Pollastri's BRNN that was proposed for PSS prediction. Our cascaded BRNN achieves an overall three state accuracy Q3 of 74.38\\%, and reaches a high Segment OVerlap (SOV) of 66.0455. It outperforms the original BRNN and Pollastri's BRNN in both Q3 and SOV. Specifically, it improves the SOV score by 4-6%.
Miller, Anne; Nightingale, Alison L; Sammon, Cormac J; Mahtani, Kamal R; Holt, Tim A; McHugh, Neil J; Luqmani, Raashid A
2015-10-01
To investigate the diagnostic accuracy of RF as a test for RA in primary care and its impact on referral times using the Clinical Practice Research Datalink. We identified all patients with a first RF test recorded in the Clinical Practice Research Datalink between 1 January 2000 and 31 December 2008 and those diagnosed with RA within 2 years of testing. We calculated likelihood ratios (LRs), sensitivity, specificity and predictive values of RF for a diagnosis of RA. We compared time to hospital referral in those testing positive and negative using Kaplan-Meier failure curves and log-rank tests. Of 62 436 first RF tests, 4679 (7.5%) were positive. There were 1753 incident cases of RA, of which 57.8% were seropositive. The positive LR for RF was 9.5 (95% CI 9.0, 10.0) and the negative LR was 0.5 (95% CI 0.4, 0.5). Sensitivity and specificity were 57.8% (95% CI 55.4%, 60.1%) and 93.9% (95% CI 93.7%, 94.1%) and the positive predictive value and negative predictive value were 21.4% (95% CI 20.3%, 22.6%) and 98.7% (95% CI 98.6%, 98.8%), respectively. Median time to first hospital contact after the first RF test in those with seropositive vs seronegative results was 54 days (95% CI 49, 58) vs 150 (95% CI 147, 152). Only 2.8% of patients undergoing RF testing were diagnosed with RA, suggesting that RF is used to screen patients with musculoskeletal symptoms rather than those with more specific features of RA. A positive RF test may be helpful in diagnosing RA in primary care but performs badly in excluding RA and may delay referral. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Harwood, Valerie J; Boehm, Alexandria B; Sassoubre, Lauren M; Vijayavel, Kannappan; Stewart, Jill R; Fong, Theng-Theng; Caprais, Marie-Paule; Converse, Reagan R; Diston, David; Ebdon, James; Fuhrman, Jed A; Gourmelon, Michele; Gentry-Shields, Jennifer; Griffith, John F; Kashian, Donna R; Noble, Rachel T; Taylor, Huw; Wicki, Melanie
2013-11-15
An inter-laboratory study of the accuracy of microbial source tracking (MST) methods was conducted using challenge fecal and sewage samples that were spiked into artificial freshwater and provided as unknowns (blind test samples) to the laboratories. The results of the Source Identification Protocol Project (SIPP) are presented in a series of papers that cover 41 MST methods. This contribution details the results of the virus and bacteriophage methods targeting human fecal or sewage contamination. Human viruses used as source identifiers included adenoviruses (HAdV), enteroviruses (EV), norovirus Groups I and II (NoVI and NoVII), and polyomaviruses (HPyVs). Bacteriophages were also employed, including somatic coliphages and F-specific RNA bacteriophages (FRNAPH) as general indicators of fecal contamination. Bacteriophage methods targeting human fecal sources included genotyping of FRNAPH isolates and plaque formation on bacterial hosts Enterococcus faecium MB-55, Bacteroides HB-73 and Bacteroides GB-124. The use of small sample volumes (≤50 ml) resulted in relatively insensitive theoretical limits of detection (10-50 gene copies or plaques × 50 ml(-1)) which, coupled with low virus concentrations in samples, resulted in high false-negative rates, low sensitivity, and low negative predictive values. On the other hand, the specificity of the human virus methods was generally close to 100% and positive predictive values were ∼40-70% with the exception of NoVs, which were not detected. The bacteriophage methods were generally much less specific toward human sewage than virus methods, although FRNAPH II genotyping was relatively successful, with 18% sensitivity and 85% specificity. While the specificity of the human virus methods engenders great confidence in a positive result, better concentration methods and larger sample volumes must be utilized for greater accuracy of negative results, i.e. the prediction that a human contamination source is absent. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sareen, Rateesh; Pandey, C L
2016-01-01
Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, J., E-mail: juliengarnon@gmail.com; Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com; Caudrelier J, J., E-mail: caudjean@yahoo.fr
2016-05-15
ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinummore » (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.« less
Basirat, Vahid; Azizi, Zahra; Javid Anbardan, Sanam; Taghizadeh Asl, Mina; Farbod, Yasaman; Teimouri, Azam; Ebrahimi Daryani, Nasser
2016-01-01
INTRODUCTION Due to limitation of colonoscopy in assessing the entire bowel and patients’ intolerance in inflammatory bowel disease (IBD), in the current study, we aimed to prospectively compare the accuracy of 99mTc(V)-dimercaptosuccinic acid (DMSA) and fecal calprotectin with ileocolonoscopy as new methods for localizing inflammations. METHODS Current prospective study conducted between 2012 and 2014 on 30 patients with IBD attending Gastroenterology Clinic of Tehran University of Medical Sciences. Fecal calprotectin and disease activity were measured for all participants and all of them underwent 99mTc (V)-DMSA scintigraphy and colonoscopy. The accuracy of 99mTc (V)-DMSA scintigraphy and calprotectin in localizing bowel lesions were calculated. RESULTS A total of 22 patients with ulcerative colitis (UC) and 8 patients with Crohn’s disease (CD) were evaluated in our study. Sensitivity, positive likelihood ratio (PLR), and positive predictive value (PPV) of scintigraphy and calprotectin over colonoscopy in localization of UC lesions were 86.36%, 0.86%, 100.00% and 90.91%, 0.91, and 100.00%, respectively. Meanwhile, it showed 66.67% sensitivity and 81.25% specificity with PLR=3.56, negative likelihood ratio (NLR)=0.41, PPV=84.21%, and negative predictive value (NPV)= 61.90% in localizing lesions in patients with CD. The calprotectin level had sensitivity, PLR, and PPV of 90.00%, 0.90, and 100.00% in detecting active disease over colonoscopy, respectively. CONCLUSION The 99mTc (V)-DMSA scintigraphy would be an accurate method for detecting active inflammation in follow-up of patients with IBD and assessing response to treatment as a non-invasive and complementary method beside colonoscopy for more accurate diagnosis of CD or UC. PMID:27698971
Chaux, Alcides
2015-10-01
To evaluate the accuracy of previously published risk group systems for predicting inguinal nodal metastases in patients with penile carcinoma. Two hundred three cases of invasive penile squamous cell carcinomas (SCC) were stratified using the following systems: Solsona et al (J Urol 2001;165:1509), Hungerhuber et al (Urology 2006;68:621), and the system proposed by the European Association of Urology (EAU; Eur Urol 2004;46:1). Receiver operating characteristic (ROC) analysis was carried out to compare accuracy in predicting final nodal status and cancer-related death. Most of cases were pT2/pT3 high-grade tumors with a small percentage of low-grade pT1 carcinomas. The metastatic rates for the Solsona et al, EAU, and Hungerhuber et al systems in the high-risk category were 15 of 73 (21%), 16 of 103 (16%), and 10 of 35 (29%) in patients with clinically negative inguinal lymph nodes and 52 of 75 (69%), 55 of 93 (59%), and 34 of 47 (72%) in patients with palpable inguinal lymph nodes, respectively. Performance by ROC analysis showed a low accuracy for all stratification systems although the Solsona et al and the Hungerhuber et al systems performed better than the EAU system. Patients in intermediate-risk categories and with clinically palpable inguinal lymph nodes were more likely to have nodal metastasis than patients with clinically negative lymph nodes in the same category. These stratification systems may be useful for patients with low-grade superficial tumors and less accurate for evaluating patients with high-grade locally advanced penile carcinomas. These data may be useful for therapeutic planning of patients with penile SCC. Copyright © 2015 Elsevier Inc. All rights reserved.
Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal
2016-01-01
Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455
Sankey, Joel B.; McVay, Jason C.; Kreitler, Jason R.; Hawbaker, Todd J.; Vaillant, Nicole; Lowe, Scott
2015-01-01
Increased sedimentation following wildland fire can negatively impact water supply and water quality. Understanding how changing fire frequency, extent, and location will affect watersheds and the ecosystem services they supply to communities is of great societal importance in the western USA and throughout the world. In this work we assess the utility of the InVEST (Integrated Valuation of Ecosystem Services and Tradeoffs) Sediment Retention Model to accurately characterize erosion and sedimentation of burned watersheds. InVEST was developed by the Natural Capital Project at Stanford University (Tallis et al., 2014) and is a suite of GIS-based implementations of common process models, engineered for high-end computing to allow the faster simulation of larger landscapes and incorporation into decision-making. The InVEST Sediment Retention Model is based on common soil erosion models (e.g., USLE – Universal Soil Loss Equation) and determines which areas of the landscape contribute the greatest sediment loads to a hydrological network and conversely evaluate the ecosystem service of sediment retention on a watershed basis. In this study, we evaluate the accuracy and uncertainties for InVEST predictions of increased sedimentation after fire, using measured postfire sediment yields available for many watersheds throughout the western USA from an existing, published large database. We show that the model can be parameterized in a relatively simple fashion to predict post-fire sediment yield with accuracy. Our ultimate goal is to use the model to accurately predict variability in post-fire sediment yield at a watershed scale as a function of future wildfire conditions.
Tural, Cristina; Tor, Jordi; Sanvisens, Arantza; Pérez-Alvarez, Núria; Martínez, Elisenda; Ojanguren, Isabel; García-Samaniego, Javier; Rockstroh, Juergen; Barluenga, Eva; Muga, Robert; Planas, Ramon; Sirera, Guillem; Rey-Joly, Celestino; Clotet, Bonaventura
2009-03-01
We assessed the ability of 3 simple biochemical tests to stage liver fibrosis in patients co-infected with human immunodeficiency virus (HIV) and hepatitis C virus (HCV). We analyzed liver biopsy samples from 324 consecutive HIV/HCV-positive patients (72% men; mean age, 38 y; mean CD4+ T-cell counts, 548 cells/mm(3)). Scheuer fibrosis scores were as follows: 30% had F0, 22% had F1, 19% had F2, 23% had F3, and 6% had F4. Logistic regression analyses were used to predict the probability of significant (>or=F2) or advanced (>or=F3) fibrosis, based on numeric scores from the APRI, FORNS, or FIB-4 tests (alone and in combination). Area under the receiver operating characteristic curves were analyzed to assess diagnostic performance. Area under the receiver operating characteristic curves analyses indicated that the 3 tests had similar abilities to identify F2 and F3; the ability of APRI, FORNS, and FIB-4 were as follows: F2 or greater: 0.72, 0.67, and 0.72, respectively; F3 or greater: 0.75, 0.73, and 0.78, respectively. The accuracy of each test in predicting which samples were F3 or greater was significantly higher than for F2 or greater (APRI, FORNS, and FIB-4: >or=F3: 75%, 76%, and 76%, respectively; >or=F2: 66%, 62%, and 68%, respectively). By using the lowest cut-off values for all 3 tests, F3 or greater was ruled out with sensitivity and negative predictive values of 79% to 94% and 87% to 91%, respectively, and 47% to 70% accuracy. Advanced liver fibrosis (>or=F3) was identified using the highest cut-off value, with specificity and positive predictive values of 90% to 96% and 63% to 73%, respectively, and 75% to 77% accuracy. Simple biochemical tests accurately predicted liver fibrosis in more than half the HIV/HCV co-infected patients. The absence and presence of liver fibrosis are predicted fairly using the lowest and highest cut-off levels, respectively.
NASA Astrophysics Data System (ADS)
Petruzzi, Massimo; Lucchese, Alberta; Nardi, Gianna Maria; Lauritano, Dorina; Favia, Gianfranco; Serpico, Rosario; Grassi, Felice Roberto
2014-07-01
The objective was to compare toluidine blue (TB) and autofluorescence (AF) for the detection of oral dysplasia and squamous cell carcinoma (OSCC) in clinically suspicious lesions according to conventional examination. Fifty-six clinically suspicious lesions were subjected to AF and TB examination. Data were compared using two different scenarios: in the first, mild dysplasia was considered as positive, while in the second, it was considered as negative. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), accuracy, and concordance were calculated. AF sensitivity and specificity were 70.0 and 57.7%, respectively, while TB showed a sensitivity of 80% and a specificity of 61.5%. The sensitivity increased in the second scenario in both AF (76.5%) and TB (88.2%). The specificity decreased in AF and TB, showing the same value (51.3%). PPV was higher in TB than in AF (70.6 versus 65.6%) and similarly for NPV (72.7 versus 62.5%). In the second scenario, TB PPV was 44.1% and NPV was 90.9% AF PPV was 40.6% and NPV was 83.3%. TB showed greater accuracy than AF in the first scenario (62.5 versus 58.9%). AF and TB are both sensitive but not specific in OSCC and dysplasia diagnosis.
Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.
Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong
2012-10-01
Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.
Comparison between breast MRI and contrast-enhanced spectral mammography.
Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy
2015-05-12
The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.
Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules
Yordanova, Anna; Mahjoob, Soha; Lingohr, Philipp; Kalff, Jörg; Türler, Andreas; Palmedo, Holger; Biersack, Hans-Jürgen; Kristiansen, Glen; Farahati, Jamshid; Essler, Markus; Ahmadzadehfar, Hojjat
2017-01-01
[99mTc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained. PMID:29212258
Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules.
Yordanova, Anna; Mahjoob, Soha; Lingohr, Philipp; Kalff, Jörg; Türler, Andreas; Palmedo, Holger; Biersack, Hans-Jürgen; Kristiansen, Glen; Farahati, Jamshid; Essler, Markus; Ahmadzadehfar, Hojjat
2017-11-07
[ 99m Tc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained.
Khan, Momna; Sultana, Syeda Seema; Jabeen, Nigar; Arain, Uzma; Khans, Salma
2015-02-01
To determine the diagnostic accuracy of visual inspection of cervix using 3% acetic acid as a screening test for early detection of cervical cancer taking histopathology as the gold standard. The cross-sectional study was conducted at Civil Hospital Karachi from July 1 to December 31, 2012 and comprised all sexually active women aged 19-60 years. During speculum examination 3% acetic acid was applied over the cervix with the help of cotton swab. The observations were noted as positive or negative on visual inspection of the cervix after acetic acid application according to acetowhite changes. Colposcopy-guided cervical biopsy was done in patients with positive or abnormal looking cervix. Colposcopic-directed biopsy was taken as the gold standard to assess visual inspection readings. SPSS 17 was used for statistical analysis. There were 500 subjects with a mean age of 35.74 ± 9.64 years. Sensitivity, specifically, positive predicted value, negative predicted value of visual inspection of the cervix after acetic acid application was 93.5%, 95.8%, 76.3%, 99%, and the diagnostic accuracy was 95.6%. Visual inspection of the cervix after acetic acid application is an effective method of detecting pre-invasive phase of cervical cancer and a good alternative to cytological screening for cervical cancer in resource-poor setting like Pakistan and can reduce maternal morbidity and mortality.
Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L
1994-01-01
The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.
Kim, Kyung Hwan; Park, Min Jung; Lim, Joon Seok; Kim, Nam Kyu; Min, Byung Soh; Ahn, Joong Bae; Kim, Tae Il; Kim, Ho Geun; Koom, Woong Sub
2016-04-01
To identify patients who are at a higher risk of pathologic circumferential resection margin involvement using preoperative magnetic resonance imaging. Between October 2008 and November 2012, 165 patients with locally advanced rectal cancer (cT4 or cT3 with <2 mm distance from tumour to mesorectal fascia) who received preoperative chemoradiotherapy were analysed. The morphologic patterns on post-chemoradiotherapy magnetic resonance imaging were categorized into five patterns from Pattern A (most-likely negative pathologic circumferential resection margin) to Pattern E (most-likely positive pathologic circumferential resection margin). In addition, the location of mesorectal fascia involvement was classified as lateral, posterior and anterior. The diagnostic accuracy of the morphologic criteria was calculated using receiver operating characteristic curve analysis. Pathologic circumferential resection margin involvement was identified in 17 patients (10.3%). The diagnostic accuracy of predicting pathologic circumferential resection margin involvement was 0.73 using the five-scale magnetic resonance imaging pattern. The sensitivity, specificity, positive predictive value and negative predictive value for predicting pathologic circumferential resection margin involvement were 76.5, 65.5, 20.3 and 96.0%, respectively, when cut-off was set between Patterns C and D. On multivariate logistic regression, the magnetic resonance imaging patterns D and E (P= 0.005) and posterior or lateral mesorectal fascia involvement (P= 0.017) were independently associated with increased probability of pathologic circumferential resection margin involvement. The rate of pathologic circumferential resection margin involvement was 30.0% when the patient had Pattern D or E with posterior or lateral mesorectal fascia involvement. Patients who are at a higher risk of pathologic circumferential resection margin involvement can be identified using preoperative magnetic resonance imaging although the predictability is moderate. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Porfyridis, Ilias; Georgiadis, Georgios; Michael, Michalis; Frangopoulos, Frangiskos; Vogazianos, Paris; Papadopoulos, Alexis; Kara, Panayiota; Charalampous, Charis; Georgiou, Andreas
2016-08-01
Medical thoracoscopy (MT) is useful for the management of pleural disease. Rapid on-site evaluation (ROSE) of transbronchial needle aspirates proved to be useful during bronchoscopy. We aimed to evaluate the diagnostic performance of ROSE of MT biopsy specimens and thoracoscopists' impression of the macroscopic appearance and assess the intermodality agreement between ROSE and final histopathologic diagnosis. Sixty two patients with exudative pleural effusions further investigated with MT were enrolled. MT was performed under local anaesthesia and conscious sedation, using the rigid pleuroscope. ROSE with the Hemacolor rapid staining method of the biopsy specimens was performed. Thoracoscopists' impression of the macroscopic appearance was recorded. The final diagnosis was established following histopathological examination. Thoracoscopic pleural biopsies were diagnosed in 61 patients (98.4%). Group A (n = 25) consisted of patients with malignancy and group B (n = 37) with benign disorders. Area under the curve of ROSE for the diagnosis of malignancy was 0.86 (95% CI: 0.76-0.96, P < 0.001), with a sensitivity of 79.17%, specificity of 94.59%, diagnostic accuracy of 88.5%, positive predictive value of 90.5% and negative predictive value of 87.5%. Intermodality agreement between ROSE and histopathology was good (κ ± SE = 0.615 ± 0.084, P < 0.001). Area under the curve of the thoracoscopists' impression of macroscopic appearance was 0.72 (95% CI: 0.58-0.85, P = 0.001), with a sensitivity of 100%, specificity of 44.7%, positive predictive value of 53.33% and negative predictive value of 100%. Rapid on-site evaluation during MT was found to have high accuracy for predicting malignancy. ROSE can provide the thoracoscopist with an on-site preliminary diagnosis, especially in cases with inconclusive macroscopic appearance. © 2016 Asian Pacific Society of Respirology.
Feil, Katharina; Feuerecker, Regina; Goldschagg, Nicolina; Strobl, Ralf; Brandt, Thomas; von Müller, Albrecht; Grill, Eva; Strupp, Michael
2018-01-01
Making the correct diagnosis of patients presenting with vertigo and dizziness in clinical practice is often challenging. In this study we examined the performance of the iPad based program me d x in the prediction of different clinical vertigo and dizziness diagnoses and as a diagnostic tool to distinguish between them. The data collection was done in the outpatient clinic of the German Center of Vertigo and Balance Disorders. The "gold standard diagnosis" was defined as the clinical diagnosis of the specialist during the visit of the patient based on standardized history and clinical examination. Another independent and blinded physician finalized each patient's case in the constellatory diagnostic system of me d x based on an algorithm using all available clinical information. These diagnoses were compared to the "gold standard" by retrospective review of the charts of the patients. The accuracy provided by me d x was defined as the number of correctly classified diagnoses. In addition, the probability of being test positive when a disease was present (sensitivity), of being test negative when a disease was absent (specificity), of having the disease when the test is positive (positive predictive value) and of not having the disease when the test is negative (negative predictive value) for the most common diagnoses were reported. Sixteen possible different vertigo and dizziness diagnoses could be provided by me d x. A total of 610 patients (mean age 58.1 ± 16.3 years, 51.2% female) were included. The accuracy for the most common diagnoses was between 82.1 and 96.6% with a sensitivity of 40 to 80.5% and a specificity of more than 80%. When analyzing the quality of me d x in a multiclass problem for the six most common clinical diagnoses, the sensitivity, specificity, positive and negative predictive values were as follows: Bilateral vestibulopathy (81.6, 97.1, 71.1, and 97.5%), Menière's disease (77.8, 97.6, 87.0, and 95.3%), benign paroxysmal positional vertigo (61.7, 98.3, 86.6, and 93.4%), downbeat nystagmus syndrome (69.6, 97.7, 71.1, and 97.5%), vestibular migraine (34.7, 97.8, 76.1, and 88.3%), and phobic postural vertigo (80.5, 82.5, 52.5, and 94.6%). This study demonstrates that me d x is a new and easy approach to screen for different diagnoses. With the high specificity and negative predictive value, the system helps to rule out differential diagnoses and can therefore also lead to a cost reduction in the health care system. However, the sensitivity was unexpectedly low, especially for vestibular migraine. All in all, this device can only be a complementary tool, in particular for non-experts in the field.
Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna
2009-10-15
Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the same. Again, when an existing method (NBmiRTar) is executed with the our proposed negative data, we observe an improvement in its performance. These clearly establish the effectiveness of the proposed approach of selecting the negative examples systematically. TargetMiner is now available as an online tool at www.isical.ac.in/ approximately bioinfo_miu
Prediction of recovery of motor function after stroke.
Stinear, Cathy
2010-12-01
Stroke is a leading cause of disability. The ability to live independently after stroke depends largely on the reduction of motor impairment and the recovery of motor function. Accurate prediction of motor recovery assists rehabilitation planning and supports realistic goal setting by clinicians and patients. Initial impairment is negatively related to degree of recovery, but inter-individual variability makes accurate prediction difficult. Neuroimaging and neurophysiological assessments can be used to measure the extent of stroke damage to the motor system and predict subsequent recovery of function, but these techniques are not yet used routinely. The use of motor impairment scores and neuroimaging has been refined by two recent studies in which these investigations were used at multiple time points early after stroke. Voluntary finger extension and shoulder abduction within 5 days of stroke predicted subsequent recovery of upper-limb function. Diffusion-weighted imaging within 7 days detected the effects of stroke on caudal motor pathways and was predictive of lasting motor impairment. Thus, investigations done soon after stroke had good prognostic value. The potential prognostic value of cortical activation and neural plasticity has been explored for the first time by two recent studies. Functional MRI detected a pattern of cortical activation at the acute stage that was related to subsequent reduction in motor impairment. Transcranial magnetic stimulation enabled measurement of neural plasticity in the primary motor cortex, which was related to subsequent disability. These studies open interesting new lines of enquiry. WHERE NEXT?: The accuracy of prediction might be increased by taking into account the motor system's capacity for functional reorganisation in response to therapy, in addition to the extent of stroke-related damage. Improved prognostic accuracy could also be gained by combining simple tests of motor impairment with neuroimaging, genotyping, and neurophysiological assessment of neural plasticity. The development of algorithms to guide the sequential combinations of these assessments could also further increase accuracy, in addition to improving rehabilitation planning and outcomes. Copyright © 2010 Elsevier Ltd. All rights reserved.
EMUDRA: Ensemble of Multiple Drug Repositioning Approaches to Improve Prediction Accuracy.
Zhou, Xianxiao; Wang, Minghui; Katsyv, Igor; Irie, Hanna; Zhang, Bin
2018-04-24
Availability of large-scale genomic, epigenetic and proteomic data in complex diseases makes it possible to objectively and comprehensively identify therapeutic targets that can lead to new therapies. The Connectivity Map has been widely used to explore novel indications of existing drugs. However, the prediction accuracy of the existing methods, such as Kolmogorov-Smirnov statistic remains low. Here we present a novel high-performance drug repositioning approach that improves over the state-of-the-art methods. We first designed an expression weighted cosine method (EWCos) to minimize the influence of the uninformative expression changes and then developed an ensemble approach termed EMUDRA (Ensemble of Multiple Drug Repositioning Approaches) to integrate EWCos and three existing state-of-the-art methods. EMUDRA significantly outperformed individual drug repositioning methods when applied to simulated and independent evaluation datasets. We predicted using EMUDRA and experimentally validated an antibiotic rifabutin as an inhibitor of cell growth in triple negative breast cancer. EMUDRA can identify drugs that more effectively target disease gene signatures and will thus be a useful tool for identifying novel therapies for complex diseases and predicting new indications for existing drugs. The EMUDRA R package is available at doi:10.7303/syn11510888. bin.zhang@mssm.edu or zhangb@hotmail.com. Supplementary data are available at Bioinformatics online.
On the joys of perceiving: Affect as feedback for perceptual predictions.
Chetverikov, Andrey; Kristjánsson, Árni
2016-09-01
How we perceive, attend to, or remember the stimuli in our environment depends on our preferences for them. Here we argue that this dependence is reciprocal: pleasures and displeasures are heavily dependent on cognitive processing, namely, on our ability to predict the world correctly. We propose that prediction errors, inversely weighted with prior probabilities of predictions, yield subjective experiences of positive or negative affect. In this way, we link affect to predictions within a predictive coding framework. We discuss how three key factors - uncertainty, expectations, and conflict - influence prediction accuracy and show how they shape our affective response. We demonstrate that predictable stimuli are, in general, preferred to unpredictable ones, though too much predictability may decrease this liking effect. Furthermore, the account successfully overcomes the "dark-room" problem, explaining why we do not avoid stimulation to minimize prediction error. We further discuss the implications of our approach for art perception and the utility of affect as feedback for predictions within a prediction-testing architecture of cognition. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Xiao; Zhang, Jun; Li, Guo-Zheng
2015-01-01
It has become a very important and full of challenge task to predict bacterial protein subcellular locations using computational methods. Although there exist a lot of prediction methods for bacterial proteins, the majority of these methods can only deal with single-location proteins. But unfortunately many multi-location proteins are located in the bacterial cells. Moreover, multi-location proteins have special biological functions capable of helping the development of new drugs. So it is necessary to develop new computational methods for accurately predicting subcellular locations of multi-location bacterial proteins. In this article, two efficient multi-label predictors, Gpos-ECC-mPLoc and Gneg-ECC-mPLoc, are developed to predict the subcellular locations of multi-label gram-positive and gram-negative bacterial proteins respectively. The two multi-label predictors construct the GO vectors by using the GO terms of homologous proteins of query proteins and then adopt a powerful multi-label ensemble classifier to make the final multi-label prediction. The two multi-label predictors have the following advantages: (1) they improve the prediction performance of multi-label proteins by taking the correlations among different labels into account; (2) they ensemble multiple CC classifiers and further generate better prediction results by ensemble learning; and (3) they construct the GO vectors by using the frequency of occurrences of GO terms in the typical homologous set instead of using 0/1 values. Experimental results show that Gpos-ECC-mPLoc and Gneg-ECC-mPLoc can efficiently predict the subcellular locations of multi-label gram-positive and gram-negative bacterial proteins respectively. Gpos-ECC-mPLoc and Gneg-ECC-mPLoc can efficiently improve prediction accuracy of subcellular localization of multi-location gram-positive and gram-negative bacterial proteins respectively. The online web servers for Gpos-ECC-mPLoc and Gneg-ECC-mPLoc predictors are freely accessible at http://biomed.zzuli.edu.cn/bioinfo/gpos-ecc-mploc/ and http://biomed.zzuli.edu.cn/bioinfo/gneg-ecc-mploc/ respectively.
Scheid, Anika; Nebel, Markus E
2012-07-09
Over the past years, statistical and Bayesian approaches have become increasingly appreciated to address the long-standing problem of computational RNA structure prediction. Recently, a novel probabilistic method for the prediction of RNA secondary structures from a single sequence has been studied which is based on generating statistically representative and reproducible samples of the entire ensemble of feasible structures for a particular input sequence. This method samples the possible foldings from a distribution implied by a sophisticated (traditional or length-dependent) stochastic context-free grammar (SCFG) that mirrors the standard thermodynamic model applied in modern physics-based prediction algorithms. Specifically, that grammar represents an exact probabilistic counterpart to the energy model underlying the Sfold software, which employs a sampling extension of the partition function (PF) approach to produce statistically representative subsets of the Boltzmann-weighted ensemble. Although both sampling approaches have the same worst-case time and space complexities, it has been indicated that they differ in performance (both with respect to prediction accuracy and quality of generated samples), where neither of these two competing approaches generally outperforms the other. In this work, we will consider the SCFG based approach in order to perform an analysis on how the quality of generated sample sets and the corresponding prediction accuracy changes when different degrees of disturbances are incorporated into the needed sampling probabilities. This is motivated by the fact that if the results prove to be resistant to large errors on the distinct sampling probabilities (compared to the exact ones), then it will be an indication that these probabilities do not need to be computed exactly, but it may be sufficient and more efficient to approximate them. Thus, it might then be possible to decrease the worst-case time requirements of such an SCFG based sampling method without significant accuracy losses. If, on the other hand, the quality of sampled structures can be observed to strongly react to slight disturbances, there is little hope for improving the complexity by heuristic procedures. We hence provide a reliable test for the hypothesis that a heuristic method could be implemented to improve the time scaling of RNA secondary structure prediction in the worst-case - without sacrificing much of the accuracy of the results. Our experiments indicate that absolute errors generally lead to the generation of useless sample sets, whereas relative errors seem to have only small negative impact on both the predictive accuracy and the overall quality of resulting structure samples. Based on these observations, we present some useful ideas for developing a time-reduced sampling method guaranteeing an acceptable predictive accuracy. We also discuss some inherent drawbacks that arise in the context of approximation. The key results of this paper are crucial for the design of an efficient and competitive heuristic prediction method based on the increasingly accepted and attractive statistical sampling approach. This has indeed been indicated by the construction of prototype algorithms.
2012-01-01
Background Over the past years, statistical and Bayesian approaches have become increasingly appreciated to address the long-standing problem of computational RNA structure prediction. Recently, a novel probabilistic method for the prediction of RNA secondary structures from a single sequence has been studied which is based on generating statistically representative and reproducible samples of the entire ensemble of feasible structures for a particular input sequence. This method samples the possible foldings from a distribution implied by a sophisticated (traditional or length-dependent) stochastic context-free grammar (SCFG) that mirrors the standard thermodynamic model applied in modern physics-based prediction algorithms. Specifically, that grammar represents an exact probabilistic counterpart to the energy model underlying the Sfold software, which employs a sampling extension of the partition function (PF) approach to produce statistically representative subsets of the Boltzmann-weighted ensemble. Although both sampling approaches have the same worst-case time and space complexities, it has been indicated that they differ in performance (both with respect to prediction accuracy and quality of generated samples), where neither of these two competing approaches generally outperforms the other. Results In this work, we will consider the SCFG based approach in order to perform an analysis on how the quality of generated sample sets and the corresponding prediction accuracy changes when different degrees of disturbances are incorporated into the needed sampling probabilities. This is motivated by the fact that if the results prove to be resistant to large errors on the distinct sampling probabilities (compared to the exact ones), then it will be an indication that these probabilities do not need to be computed exactly, but it may be sufficient and more efficient to approximate them. Thus, it might then be possible to decrease the worst-case time requirements of such an SCFG based sampling method without significant accuracy losses. If, on the other hand, the quality of sampled structures can be observed to strongly react to slight disturbances, there is little hope for improving the complexity by heuristic procedures. We hence provide a reliable test for the hypothesis that a heuristic method could be implemented to improve the time scaling of RNA secondary structure prediction in the worst-case – without sacrificing much of the accuracy of the results. Conclusions Our experiments indicate that absolute errors generally lead to the generation of useless sample sets, whereas relative errors seem to have only small negative impact on both the predictive accuracy and the overall quality of resulting structure samples. Based on these observations, we present some useful ideas for developing a time-reduced sampling method guaranteeing an acceptable predictive accuracy. We also discuss some inherent drawbacks that arise in the context of approximation. The key results of this paper are crucial for the design of an efficient and competitive heuristic prediction method based on the increasingly accepted and attractive statistical sampling approach. This has indeed been indicated by the construction of prototype algorithms. PMID:22776037
Diagnostic Accuracy of the Veteran Affairs' Traumatic Brain Injury Screen.
Louise Bender Pape, Theresa; Smith, Bridget; Babcock-Parziale, Judith; Evans, Charlesnika T; Herrold, Amy A; Phipps Maieritsch, Kelly; High, Walter M
2018-01-31
To comprehensively estimate the diagnostic accuracy and reliability of the Department of Veterans Affairs (VA) Traumatic Brain Injury (TBI) Clinical Reminder Screen (TCRS). Cross-sectional, prospective, observational study using the Standards for Reporting of Diagnostic Accuracy criteria. Three VA Polytrauma Network Sites. Operation Iraqi Freedom, Operation Enduring Freedom veterans (N=433). TCRS, Comprehensive TBI Evaluation, Structured TBI Diagnostic Interview, Symptom Attribution and Classification Algorithm, and Clinician-Administered Posttraumatic Stress Disorder (PTSD) Scale. Forty-five percent of veterans screened positive on the TCRS for TBI. For detecting occurrence of historical TBI, the TCRS had a sensitivity of .56 to .74, a specificity of .63 to .93, a positive predictive value (PPV) of 25% to 45%, a negative predictive value (NPV) of 91% to 94%, and a diagnostic odds ratio (DOR) of 4 to 13. For accuracy of attributing active symptoms to the TBI, the TCRS had a sensitivity of .64 to .87, a specificity of .59 to .89, a PPV of 26% to 32%, an NPV of 92% to 95%, and a DOR of 6 to 9. The sensitivity was higher for veterans with PTSD (.80-.86) relative to veterans without PTSD (.57-.82). The specificity, however, was higher among veterans without PTSD (.75-.81) relative to veterans with PTSD (.36-.49). All indices of diagnostic accuracy changed when participants with questionably valid (QV) test profiles were eliminated from analyses. The utility of the TCRS to screen for mild TBI (mTBI) depends on the stringency of the diagnostic reference standard to which it is being compared, the presence/absence of PTSD, and QV test profiles. Further development, validation, and use of reproducible diagnostic algorithms for symptom attribution after possible mTBI would improve diagnostic accuracy. Published by Elsevier Inc.
Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.
2015-01-01
Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048
Deng, Han; Qi, Xingshun; Guo, Xiaozhong
2015-10-01
Aspartate aminotransferase-to-platelet ratio (APRI), aspartate aminotransferase-to-alanine aminotransferase ratio (AAR), FIB-4, FI, King, Lok, Forns, and FibroIndex scores may be simple and convenient noninvasive diagnostic tests, because they are based on the regular laboratory tests and demographic data. This study aimed to systematically evaluate their diagnostic accuracy for the prediction of varices in liver cirrhosis.All relevant papers were searched via PubMed, EMBASE, CNKI, and Wanfang databases. The area under the summary receiver operating characteristic curve (AUSROC), sensitivity, specificity, positive and negative likelihood ratio (PLR and NLR), and diagnostic odds ratio (DOR) were calculated.Overall, 12, 4, 5, 0, 0, 4, 3, and 1 paper was identified to explore the diagnostic accuracy of APRI, AAR, FIB-4, FI, King, Lok, Forns, and FibroIndex scores, respectively. The AUSROCs of APRI, AAR, FIB-4, Lok, and Forns scores for the prediction of varices were 0.6774, 0.7275, 0.7755, 0.7885, and 0.7517, respectively; and those for the prediction of large varices were 0.7278, 0.7448, 0.7095, 0.7264, and 0.6530, respectively. The diagnostic threshold effects of FIB-4 and Forns scores for the prediction of varices were statistically significant. The sensitivities/specificities/PLRs/NLRs/DORs of APRI, AAR, and Lok scores for the prediction of varices were 0.60/0.67/1.77/0.58/3.13, 0.64/0.63/1.97/0.54/4.18, and 0.74/0.68/2.34/0.40/5.76, respectively. The sensitivities/specificities/PLRs/NLRs/DORs of APRI, AAR, FIB-4, Lok, and Forns scores for the prediction of large varices were 0.65/0.66/2.15/0.47/4.97, 0.68/0.58/2.07/0.54/3.93, 0.62/0.64/2.02/0.56/3.57, 0.78/0.63/2.09/0.37/5.55, and 0.65/0.61/1.62/0.59/2.75, respectively.APRI, AAR, FIB-4, Lok, and Forns scores had low to moderate diagnostic accuracy in predicting the presence of varices in liver cirrhosis.
MultiMiTar: a novel multi objective optimization based miRNA-target prediction method.
Mitra, Ramkrishna; Bandyopadhyay, Sanghamitra
2011-01-01
Machine learning based miRNA-target prediction algorithms often fail to obtain a balanced prediction accuracy in terms of both sensitivity and specificity due to lack of the gold standard of negative examples, miRNA-targeting site context specific relevant features and efficient feature selection process. Moreover, all the sequence, structure and machine learning based algorithms are unable to distribute the true positive predictions preferentially at the top of the ranked list; hence the algorithms become unreliable to the biologists. In addition, these algorithms fail to obtain considerable combination of precision and recall for the target transcripts that are translationally repressed at protein level. In the proposed article, we introduce an efficient miRNA-target prediction system MultiMiTar, a Support Vector Machine (SVM) based classifier integrated with a multiobjective metaheuristic based feature selection technique. The robust performance of the proposed method is mainly the result of using high quality negative examples and selection of biologically relevant miRNA-targeting site context specific features. The features are selected by using a novel feature selection technique AMOSA-SVM, that integrates the multi objective optimization technique Archived Multi-Objective Simulated Annealing (AMOSA) and SVM. MultiMiTar is found to achieve much higher Matthew's correlation coefficient (MCC) of 0.583 and average class-wise accuracy (ACA) of 0.8 compared to the others target prediction methods for a completely independent test data set. The obtained MCC and ACA values of these algorithms range from -0.269 to 0.155 and 0.321 to 0.582, respectively. Moreover, it shows a more balanced result in terms of precision and sensitivity (recall) for the translationally repressed data set as compared to all the other existing methods. An important aspect is that the true positive predictions are distributed preferentially at the top of the ranked list that makes MultiMiTar reliable for the biologists. MultiMiTar is now available as an online tool at www.isical.ac.in/~bioinfo_miu/multimitar.htm. MultiMiTar software can be downloaded from www.isical.ac.in/~bioinfo_miu/multimitar-download.htm.
Evaluation of approaches for estimating the accuracy of genomic prediction in plant breeding
2013-01-01
Background In genomic prediction, an important measure of accuracy is the correlation between the predicted and the true breeding values. Direct computation of this quantity for real datasets is not possible, because the true breeding value is unknown. Instead, the correlation between the predicted breeding values and the observed phenotypic values, called predictive ability, is often computed. In order to indirectly estimate predictive accuracy, this latter correlation is usually divided by an estimate of the square root of heritability. In this study we use simulation to evaluate estimates of predictive accuracy for seven methods, four (1 to 4) of which use an estimate of heritability to divide predictive ability computed by cross-validation. Between them the seven methods cover balanced and unbalanced datasets as well as correlated and uncorrelated genotypes. We propose one new indirect method (4) and two direct methods (5 and 6) for estimating predictive accuracy and compare their performances and those of four other existing approaches (three indirect (1 to 3) and one direct (7)) with simulated true predictive accuracy as the benchmark and with each other. Results The size of the estimated genetic variance and hence heritability exerted the strongest influence on the variation in the estimated predictive accuracy. Increasing the number of genotypes considerably increases the time required to compute predictive accuracy by all the seven methods, most notably for the five methods that require cross-validation (Methods 1, 2, 3, 4 and 6). A new method that we propose (Method 5) and an existing method (Method 7) used in animal breeding programs were the fastest and gave the least biased, most precise and stable estimates of predictive accuracy. Of the methods that use cross-validation Methods 4 and 6 were often the best. Conclusions The estimated genetic variance and the number of genotypes had the greatest influence on predictive accuracy. Methods 5 and 7 were the fastest and produced the least biased, the most precise, robust and stable estimates of predictive accuracy. These properties argue for routinely using Methods 5 and 7 to assess predictive accuracy in genomic selection studies. PMID:24314298
Evaluation of approaches for estimating the accuracy of genomic prediction in plant breeding.
Ould Estaghvirou, Sidi Boubacar; Ogutu, Joseph O; Schulz-Streeck, Torben; Knaak, Carsten; Ouzunova, Milena; Gordillo, Andres; Piepho, Hans-Peter
2013-12-06
In genomic prediction, an important measure of accuracy is the correlation between the predicted and the true breeding values. Direct computation of this quantity for real datasets is not possible, because the true breeding value is unknown. Instead, the correlation between the predicted breeding values and the observed phenotypic values, called predictive ability, is often computed. In order to indirectly estimate predictive accuracy, this latter correlation is usually divided by an estimate of the square root of heritability. In this study we use simulation to evaluate estimates of predictive accuracy for seven methods, four (1 to 4) of which use an estimate of heritability to divide predictive ability computed by cross-validation. Between them the seven methods cover balanced and unbalanced datasets as well as correlated and uncorrelated genotypes. We propose one new indirect method (4) and two direct methods (5 and 6) for estimating predictive accuracy and compare their performances and those of four other existing approaches (three indirect (1 to 3) and one direct (7)) with simulated true predictive accuracy as the benchmark and with each other. The size of the estimated genetic variance and hence heritability exerted the strongest influence on the variation in the estimated predictive accuracy. Increasing the number of genotypes considerably increases the time required to compute predictive accuracy by all the seven methods, most notably for the five methods that require cross-validation (Methods 1, 2, 3, 4 and 6). A new method that we propose (Method 5) and an existing method (Method 7) used in animal breeding programs were the fastest and gave the least biased, most precise and stable estimates of predictive accuracy. Of the methods that use cross-validation Methods 4 and 6 were often the best. The estimated genetic variance and the number of genotypes had the greatest influence on predictive accuracy. Methods 5 and 7 were the fastest and produced the least biased, the most precise, robust and stable estimates of predictive accuracy. These properties argue for routinely using Methods 5 and 7 to assess predictive accuracy in genomic selection studies.
NASA Astrophysics Data System (ADS)
Arantes Camargo, Livia; Marques, José, Jr.
2015-04-01
The prediction of erodibility using indirect methods such as diffuse reflectance spectroscopy could facilitate the characterization of the spatial variability in large areas and optimize implementation of conservation practices. The aim of this study was to evaluate the prediction of interrill erodibility (Ki) and rill erodibility (Kr) by means of iron oxides content and soil color using multiple linear regression and diffuse reflectance spectroscopy (DRS) using regression analysis by least squares partial (PLSR). The soils were collected from three geomorphic surfaces and analyzed for chemical, physical and mineralogical properties, plus scanned in the spectral range from the visible and infrared. Maps of spatial distribution of Ki and Kr were built with the values calculated by the calibrated models that obtained the best accuracy using geostatistics. Interrill-rill erodibility presented negative correlation with iron extracted by dithionite-citrate-bicarbonate, hematite, and chroma, confirming the influence of iron oxides in soil structural stability. Hematite and hue were the attributes that most contributed in calibration models by multiple linear regression for the prediction of Ki (R2 = 0.55) and Kr (R2 = 0.53). The diffuse reflectance spectroscopy via PLSR allowed to predict Interrill-rill erodibility with high accuracy (R2adj = 0.76, 0.81 respectively and RPD> 2.0) in the range of the visible spectrum (380-800 nm) and the characterization of the spatial variability of these attributes by geostatistics.
Thirumala, Parthasarathy D; Thiagarajan, Karthy; Gedela, Satyanarayana; Crammond, Donald J; Balzer, Jeffrey R
2016-03-01
The 30 day stroke rate following carotid endarterectomy (CEA) ranges between 2-6%. Such periprocedural strokes are associated with a three-fold increased risk of mortality. Our primary aim was to determine the diagnostic accuracy of electroencephalogram (EEG) in predicting perioperative strokes through meta-analysis of existing literature. An extensive search for relevant literature was undertaken using PubMed and Web of Science databases. Studies were included after screening using predetermined criteria. Data was extracted and analyzed. Summary sensitivity, specificity and diagnostic odds ratio were obtained. Subgroup analysis of studies using eight or more EEG channels was done. Perioperative stroke rate for the cohort of 8765 patients was 1.75%. Pooled sensitivity and specificity of EEG changes in predicting these strokes were 52% (95% confidence interval [CI], 43-61%) and 84% (95% CI, 81-86%) respectively. Summary estimates of the subgroup were similar. The diagnostic odds ratio was 5.85 (95% CI, 3.71-9.22). For the observed stroke rate, the positive likelihood ratio was 3.25 while the negative predictive value was 98.99%. According to these results, patients with perioperative strokes have six times greater odds of experiencing an intraoperative change in EEG during CEA. EEG monitoring was found to be highly specific in predicting perioperative strokes after CEA. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rajeev, Aysha; Tuinebreijer, Wim; Mohamed, Abdalla; Newby, Mike
2018-01-01
The assessment of a patient with chronic hip pain can be challenging. The differential diagnosis of intra-articular pathology causing hip pain can be diverse. These includes conditions such as osteoarthritis, fracture, and avascular necrosis, synovitis, loose bodies, labral tears, articular pathology and, femoro-acetabular impingement. Magnetic resonance imaging (MRI) arthrography of the hip has been widely used now for diagnosis of articular pathology of the hip. A retrospective analysis of 113 patients who had MRI arthrogram and who underwent hip arthroscopy was included in the study. The MRI arthrogram was performed using gadolinium injection and reported by a single radiologist. The findings were then compared to that found on arthroscopy. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy and 95% confidence interval were calculated for each pathology. Labral tear-sensitivity 84% (74.3-90.5), specificity 64% (40.7-82.8), PPV 91% (82.1-95.8), NPV 48% (29.5-67.5), accuracy 80%. Delamination -sensitivity 7% (0.8-22.1), specificity 98% (91.6-99.7), PPV 50% (6.8-93.2), NPV 74% (65.1-82.2) and accuracy 39%. Chondral changes-sensitivity 25% (13.3-38.9), specificity 83% (71.3-91.1), PPV 52% (30.6-73.2), NPV 59% (48.0-69.2) and accuracy 58%. Femoro-acetabular impingement (CAM deformity)-sensitivity 34% (19.6-51.4), specificity 83% (72.2-90.4), PPV 50% (29.9-70.1), NPV 71% (60.6-80.5) and accuracy 66%. Synovitis-sensitivity 11% (2.3-28.2), specificity 99% (93.6-100), PPV 75% (19.4-99.4), NPV 77% (68.1-84.6) and accuracy 77%. Our study conclusions are MRI arthrogram is a useful investigation tool in detecting labral tears, it is also helpful in the diagnosis of femoro-acetabular impingement. However, when it comes to the diagnosis of chondral changes, defects and cartilage delamination, the sensitivity and accuracy are low.
Kimura, Kenta; Kimura, Motohiro
2016-09-28
The evaluative processing of the valence of action feedback is reflected by an event-related brain potential component called feedback-related negativity (FRN) or reward positivity (RewP). Recent studies have shown that FRN/RewP is markedly reduced when the action-feedback interval is long (e.g. 6000 ms), indicating that an increase in the action-feedback interval can undermine the evaluative processing of the valence of action feedback. The aim of the present study was to investigate whether or not such undermined evaluative processing of delayed action feedback could be restored by improving the accuracy of the prediction in terms of the timing of action feedback. With a typical gambling task in which the participant chose one of two cards and received an action feedback indicating monetary gain or loss, the present study showed that FRN/RewP was significantly elicited even when the action-feedback interval was 6000 ms, when an auditory stimulus sequence was additionally presented during the action-feedback interval as a temporal cue. This result suggests that the undermined evaluative processing of delayed action feedback can be restored by increasing the accuracy of the prediction on the timing of the action feedback.
Jeong, Seok Hoo; Yoon, Hyun Hwa; Kim, Eui Joo; Kim, Yoon Jae; Kim, Yeon Suk; Cho, Jae Hee
2017-01-01
Abstract Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the accurate diagnostic method for pancreatic masses and its accuracy is affected by various FNA methods and EUS equipment. Therefore, we aimed to elucidate the instrumental and methodologic factors for determining the diagnostic yield of EUS-FNA for pancreatic solid masses without an on-site cytopathology evaluation. We retrospectively reviewed the medical records of 260 patients (265 pancreatic solid masses) who underwent EUS-FNA. We compared historical conventional EUS groups with high-resolution imaging devices and finally analyzed various factors affecting EUS-FNA accuracy. In total, 265 pancreatic solid masses of 260 patients were included in this study. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNA for pancreatic solid masses without on-site cytopathology evaluation were 83.4%, 81.8%, 100.0%, 100.0%, and 34.3%, respectively. In comparison with conventional image group, high-resolution image group showed the increased accuracy, sensitivity and specificity of EUS-FNA (71.3% vs 92.7%, 68.9% vs 91.9%, and 100% vs 100%, respectively). On the multivariate analysis with various instrumental and methodologic factors, high-resolution imaging (P = 0.040, odds ratio = 3.28) and 3 or more needle passes (P = 0.039, odds ratio = 2.41) were important factors affecting diagnostic yield of pancreatic solid masses. High-resolution imaging and 3 or more passes were the most significant factors influencing diagnostic yield of EUS-FNA in patients with pancreatic solid masses without an on-site cytopathologist. PMID:28079803
Accuracy of three-dimensional multislice view Doppler in diagnosis of morbid adherent placenta
Abdel Moniem, Alaa M.; Ibrahim, Ahmed; Akl, Sherif A.; Aboul-Enen, Loay; Abdelazim, Ibrahim A.
2015-01-01
Objective To detect the accuracy of the three-dimensional multislice view (3D MSV) Doppler in the diagnosis of morbid adherent placenta (MAP). Material and Methods Fifty pregnant women at ≥28 weeks gestation with suspected MAP were included in this prospective study. Two dimensional (2D) trans-abdominal gray-scale ultrasound scan was performed for the subjects to confirm the gestational age, placental location, and findings suggestive of MAP, followed by the 3D power Doppler and then the 3D MSV Doppler to confirm the diagnosis of MAP. Intraoperative findings and histopathology results of removed uteri in cases managed by emergency hysterectomy were compared with preoperative sonographic findings to detect the accuracy of the 3D MSV Doppler in the diagnosis of MAP. Results The 3D MSV Doppler increased the accuracy and predictive values of the diagnostic criteria of MAP compared with the 3D power Doppler. The sensitivity and negative predictive value (NPV) (79.6% and 82.2%, respectively) of crowded vessels over the peripheral sub-placental zone to detect difficult placental separation and considerable intraoperative blood loss in cases of MAP using the 3D power Doppler was increased to 82.6% and 84%, respectively, using the 3D MSV Doppler. In addition, the sensitivity, specificity, and positive predictive value (PPV) (90.9%, 68.8%, and 47%, respectively) of the disruption of the uterine serosa-bladder interface for the detection of emergency hysterectomy in cases of MAP using the 3D power Doppler was increased to 100%, 71.8%, and 50%, respectively, using the 3D MSV Doppler. Conclusion The 3D MSV Doppler is a useful adjunctive tool to the 3D power Doppler or color Doppler to refine the diagnosis of MAP. PMID:26401104
Gamage, Sujani Madhurika Kodagoda; Wijeweera, Indunil; Wijesinghe, Priyangi; Adikari, Sanjaya Bandara; Fink, Katharina; Sominanda, Herath Mudiyanselage Ajith
2018-05-31
The magnetic resonance imaging in multiple sclerosis (MAGNIMS) group recently proposed guidelines to replace the existing dissemination-in-space criteria in McDonald 2010 magnetic resonance imaging (MRI) criteria for diagnosing multiple sclerosis. There has been insufficient research regarding their applicability in Asians. Objective of this study was to determine the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of McDonald 2010 and MAGNIMS 2016 MRI criteria with the aim of verifying their applicability in Sri Lankan patients. Patients with clinically isolated syndrome diagnosed by consultant neurologists were recruited from five major neurology centers. Baseline and follow-up MRI scans were performed within 3 months from the initial presentation and at one year after baseline MRI, respectively. McDonald 2010 and MAGNIMS 2016 MRI criteria were applied to all MRI scans. Patients were followed-up for 2 years to assess the conversion to clinically definite multiple sclerosis (CDMS). The sensitivity, specificity, accuracy, PPV, and NPV for predicting the conversion to CDMS were calculated. Forty-two of 66 patients converted to CDMS. Thirty-seven fulfilled the McDonald 2010 MRI criteria, and 33 converted to CDMS. MAGNIMS 2016 MRI criteria were fulfilled by 29, with 28 converting to CDMS. The sensitivity, specificity, accuracy, PPV, and NPV were 78%, 83%, 64%, 89%, and 69%, respectively, for the McDonald 2010 criteria, and 67%, 96%, 77%, 96%, and 62% for the MAGNIMS 2016 MRI criteria. MAGNIMS 2016 MRI criteria were superior to McDonald 2010 MRI criteria in specificity, accuracy, and PPV, but inferior in sensitivity and NPV. Copyright © 2018 Korean Neurological Association.
Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.
Holm, Anne; Aabenhus, Rune
2016-06-08
Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Shangang, E-mail: 1198685580@qq.com; Li, Chengli, E-mail: chenglilichina@yeah.net; Yu, Xuejuan, E-mail: yuxuejuan2011@126.com
2015-04-15
ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chestmore » tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.« less
Refinement of detecting atrial fibrillation in stroke patients: results from the TRACK-AF Study.
Reinke, F; Bettin, M; Ross, L S; Kochhäuser, S; Kleffner, I; Ritter, M; Minnerup, J; Dechering, D; Eckardt, L; Dittrich, R
2018-04-01
Detection of occult atrial fibrillation (AF) is crucial for optimal secondary prevention in stroke patients. The AF detection rate was determined by implantable cardiac monitor (ICM) and compared to the prediction rate of the probability of incident AF by software based analysis of a continuously monitored electrocardiogram at follow-up (stroke risk analysis, SRA); an optimized AF detection algorithm is proposed by combining both tools. In a monocentric prospective study 105 out of 389 patients with cryptogenic stroke despite extensive diagnostic workup were investigated with two additional cardiac monitoring tools: (a) 20 months' monitoring by ICM and (b) SRA during hospitalization at the stroke unit. The detection rate of occult AF was 18% by ICM (n = 19) (range 6-575 days) and 62% (n = 65) had an increased risk for AF predicted by SRA. When comparing the predictive accuracy of SRA to ICM, the sensitivity was 95%, specificity 35%, positive predictive value 27% and negative predictive value 96%. In 18 patients with AF detected by ICM, SRA also showed a medium risk for AF. Only one patient with a very low risk predicted by SRA developed AF revealed by ICM after 417 days. A combination of SRA and ICM is a promising strategy to detect occult AF. SRA is reliable in predicting incident AF with a high negative predictive value. Thus, SRA may serve as a cost-effective pre-selection tool identifying patients at risk for AF who may benefit from further cardiac monitoring by ICM. © 2017 EAN.
Safari, Saeed; Baratloo, Alireza; Hashemi, Behrooz; Rahmati, Farhad; Forouzanfar, Mohammad Mehdi; Motamedi, Maryam; Mirmohseni, Ladan
2016-01-01
Determining etiologic causes and prognosis can significantly improve management of syncope patients. The present study aimed to compare the values of San Francisco, Osservatorio Epidemiologico sulla Sincope nel Lazio (OESIL), Boston, and Risk Stratification of Syncope in the Emergency Department (ROSE) score clinical decision rules in predicting the short-term serious outcome of syncope patients. The present diagnostic accuracy study with 1-week follow-up was designed to evaluate the predictive values of the four mentioned clinical decision rules. Screening performance characteristics of each model in predicting mortality, myocardial infarction (MI), and cerebrovascular accidents (CVAs) were calculated and compared. To evaluate the value of each aforementioned model in predicting the outcome, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were calculated and receiver-operating curve (ROC) curve analysis was done. A total of 187 patients (mean age: 64.2 ± 17.2 years) were enrolled in the study. Mortality, MI, and CVA were seen in 19 (10.2%), 12 (6.4%), and 36 (19.2%) patients, respectively. Area under the ROC curve for OESIL, San Francisco, Boston, and ROSE models in prediction the risk of 1-week mortality, MI, and CVA was in the 30-70% range, with no significant difference among models ( P > 0.05). The pooled model did not show higher accuracy in prediction of mortality, MI, and CVA compared to others ( P > 0.05). This study revealed the weakness of all four evaluated models in predicting short-term serious outcome of syncope patients referred to the emergency department without any significant advantage for one among others.
Computational prediction of type III and IV secreted effectors in Gram-negative bacteria
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDermott, Jason E.; Corrigan, Abigail L.; Peterson, Elena S.
2011-01-01
In this review, we provide an overview of the methods employed by four recent papers that described novel methods for computational prediction of secreted effectors from type III and IV secretion systems in Gram-negative bacteria. The results of the studies in terms of performance at accurately predicting secreted effectors and similarities found between secretion signals that may reflect biologically relevant features for recognition. We discuss the web-based tools for secreted effector prediction described in these studies and announce the availability of our tool, the SIEVEserver (http://www.biopilot.org). Finally, we assess the accuracy of the three type III effector prediction methods onmore » a small set of proteins not known prior to the development of these tools that we have recently discovered and validated using both experimental and computational approaches. Our comparison shows that all methods use similar approaches and, in general arrive at similar conclusions. We discuss the possibility of an order-dependent motif in the secretion signal, which was a point of disagreement in the studies. Our results show that there may be classes of effectors in which the signal has a loosely defined motif, and others in which secretion is dependent only on compositional biases. Computational prediction of secreted effectors from protein sequences represents an important step toward better understanding the interaction between pathogens and hosts.« less
Hiersch, Liran; Yogev, Yariv; Domniz, Noam; Meizner, Israel; Bardin, Ron; Melamed, Nir
2014-11-01
To determine whether the predictive accuracy of sonographic cervical length (CL) for preterm delivery (PTD) in women with threatened preterm labor (PTL) is related to gestational age (GA) at presentation. A retrospective cohort study of all women with singleton pregnancies who presented with PTL at less than 34 + 0 weeks and underwent sonographic measurement of CL in a tertiary medical center between 2007 and 2012. The predictive accuracy of CL for PTD was stratified by GA at presentation. Overall, 1077 women who presented with PTL have had sonographic measurement of CL and met the study inclusion criteria. Of those, 223 (20.7%) presented at 24 + 0-26 + 6 weeks (group 1), 274 (25.4%) at 27 + 0-29 + 6 weeks (group 2), 283 (26.3%) at 30 + 0-31 + 6 weeks (group 3), and 297 (27.6%) at 32 + 0-33 + 6 weeks (group 4). The overall performance CL as a predictive test for PTD was similar in the 4 GA groups, as reflected by the similar degree of correlation between CL with the examination to delivery interval (r = 0.27, r = 0.26, r = 0.28, and r = 0.29, respectively, P = .8), the similar area under the receiver-operator characteristic curve (0.641-0.690, 0.631-0.698, 0.643-0.654, and 0.678-0.698, respectively, P = .7), and a similar decrease in the risk of PTD of 5-10% for each additional millimeter of CL. The optimal cutoff of CL, however, was affected by GA at presentation, so that a higher cutoff of CL was needed to achieve a target negative predictive value for delivery within 14 days from presentation for women who presented later in pregnancy. The optimal thresholds to maximize the negative predictive value for delivery within 14 days were 36 mm, 32.5 mm, 24 mm and 20.5 mm for women who presented at 32 + 0 to 33 + 6 weeks, 30 + 0 to 31 + 6 weeks, 27 + 0 to 29 + 6 weeks and 24 + 0 to 26 + 6, respectively. CL has modest predictive accuracy in women with threatened PTL, regardless of GA at presentation. However, the optimal cutoff of CL for the purpose of clinical decision making in women with PTL needs to be adjusted based on GA at presentation. Copyright © 2014 Elsevier Inc. All rights reserved.
Genomic signals of selection predict climate-driven population declines in a migratory bird.
Bay, Rachael A; Harrigan, Ryan J; Underwood, Vinh Le; Gibbs, H Lisle; Smith, Thomas B; Ruegg, Kristen
2018-01-05
The ongoing loss of biodiversity caused by rapid climatic shifts requires accurate models for predicting species' responses. Despite evidence that evolutionary adaptation could mitigate climate change impacts, evolution is rarely integrated into predictive models. Integrating population genomics and environmental data, we identified genomic variation associated with climate across the breeding range of the migratory songbird, yellow warbler ( Setophaga petechia ). Populations requiring the greatest shifts in allele frequencies to keep pace with future climate change have experienced the largest population declines, suggesting that failure to adapt may have already negatively affected populations. Broadly, our study suggests that the integration of genomic adaptation can increase the accuracy of future species distribution models and ultimately guide more effective mitigation efforts. Copyright © 2018, American Association for the Advancement of Science.
Estimation of proteinuria as a predictor of complications of pre-eclampsia: a systematic review
Thangaratinam, Shakila; Coomarasamy, Arri; O'Mahony, Fidelma; Sharp, Steve; Zamora, Javier; Khan, Khalid S; Ismail, Khaled MK
2009-01-01
Background Proteinuria is one of the essential criteria for the clinical diagnosis of pre-eclampsia. Increasing levels of proteinuria is considered to be associated with adverse maternal and fetal outcomes. We aim to determine the accuracy with which the amount of proteinuria predicts maternal and fetal complications in women with pre-eclampsia by systematic quantitative review of test accuracy studies. Methods We conducted electronic searches in MEDLINE (1951 to 2007), EMBASE (1980 to 2007), the Cochrane Library (2007) and the MEDION database to identify relevant articles and hand-search of selected specialist journals and reference lists of articles. There were no language restrictions for any of these searches. Two reviewers independently selected those articles in which the accuracy of proteinuria estimate was evaluated to predict maternal and fetal complications of pre-eclampsia. Data were extracted on study characteristics, quality and accuracy to construct 2 × 2 tables with maternal and fetal complications as reference standards. Results Sixteen primary articles with a total of 6749 women met the selection criteria with levels of proteinuria estimated by urine dipstick, 24-hour urine proteinuria or urine protein:creatinine ratio as a predictor of complications of pre-eclampsia. All 10 studies predicting maternal outcomes showed that proteinuria is a poor predictor of maternal complications in women with pre-eclampsia. Seventeen studies used laboratory analysis and eight studies bedside analysis to assess the accuracy of proteinuria in predicting fetal and neonatal complications. Summary likelihood ratios of positive and negative tests for the threshold level of 5 g/24 h were 2.0 (95% CI 1.5, 2.7) and 0.53 (95% CI 0.27, 1) for stillbirths, 1.5 (95% CI 0.94, 2.4) and 0.73 (95% CI 0.39, 1.4) for neonatal deaths and 1.5 (95% 1, 2) and 0.78 (95% 0.64, 0.95) for Neonatal Intensive Care Unit admission. Conclusion Measure of proteinuria is a poor predictor of either maternal or fetal complications in women with pre-eclampsia. PMID:19317889
Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K
2014-12-01
The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.
Liu, Zhihong; Zheng, Minghao; Yan, Xin; Gu, Qiong; Gasteiger, Johann; Tijhuis, Johan; Maas, Peter; Li, Jiabo; Xu, Jun
2014-09-01
Predicting compound chemical stability is important because unstable compounds can lead to either false positive or to false negative conclusions in bioassays. Experimental data (COMDECOM) measured from DMSO/H2O solutions stored at 50 °C for 105 days were used to predicted stability by applying rule-embedded naïve Bayesian learning, based upon atom center fragment (ACF) features. To build the naïve Bayesian classifier, we derived ACF features from 9,746 compounds in the COMDECOM dataset. By recursively applying naïve Bayesian learning from the data set, each ACF is assigned with an expected stable probability (p(s)) and an unstable probability (p(uns)). 13,340 ACFs, together with their p(s) and p(uns) data, were stored in a knowledge base for use by the Bayesian classifier. For a given compound, its ACFs were derived from its structure connection table with the same protocol used to drive ACFs from the training data. Then, the Bayesian classifier assigned p(s) and p(uns) values to the compound ACFs by a structural pattern recognition algorithm, which was implemented in-house. Compound instability is calculated, with Bayes' theorem, based upon the p(s) and p(uns) values of the compound ACFs. We were able to achieve performance with an AUC value of 84% and a tenfold cross validation accuracy of 76.5%. To reduce false negatives, a rule-based approach has been embedded in the classifier. The rule-based module allows the program to improve its predictivity by expanding its compound instability knowledge base, thus further reducing the possibility of false negatives. To our knowledge, this is the first in silico prediction service for the prediction of the stabilities of organic compounds.
Binesh, Fariba; Pirdehghan, Azar; Mirjalili, Mohammad Reza; Samet, Mohammad; Majomerd, Zahra Amini; Akhavan, Ali
2015-01-01
This study was designed to determine the accuracy of bronchoalveolar lavage fluid cytology (BAL) using histopathologic examination of transbronchial biopsy specimens as the gold standard in diagnosis of lung carcinoma at our center. A retrospective study was conducted to investigate a total of 388 patients who were suspected of having lung cancer and had undergone fiberoptic bronchoscopy in Shahid Sadoughi hospital from 2006 to 2011. Lung masses were proven to be malignant by histology. Transbronchial lung biopsy (TBLB) identified malignancy in 183 of the 388 cases, including 48 cases (26.2%) with adenocarcinoma, 4(2.1%) with bronchioloalveolar carcinoma, 47(25.6%)with squamous cell carcinoma, 34(18.5%) with well-diffentiated neuroendocrine carcinoma, 35(19.1%) with small cell carcinoma, 14 (7.6%) with non-small cell carcinoma, and 1 (0.54%) with large cell carcinoma. A total of 205 cases were correctly classified as negative. BAL was also performed in 388 patients; 86/103 cases were consistent with the final diagnosis of lung cancer and 188/285 cases were correctly classified as negative. The sensitivity of BAL was 46.9%(CI:41.9%, 51.8%)) and its specificity was 91.6%(CI:88.8%, 94.3%). BAL had a positive predictive value (PPV) of 83.4%(CI:79.7%, 87.1%) and a negative predictive value (NPV) of 65.8%(CI:61%, 70.5%). The overall accuracy of BAL was 70.5% and the exact concordance was 39%. Our findings suggest that BAL cytology is not sensitive but is a specific test for diagnosis of lung carcinoma. If transbronchial lung biopsy is combined with bronchoalveolar lavage, the positive diagnostic rate will be further elevated.
Chen, Jin-feng; Liu, Yi-nan; Wu, Nan; Feng, Yuan; Wang, Jia; Lü, Chao; Wang, Yu-zhao; Pei, Yu-quan; Yan, Shi; Zheng, Qing-feng; Zhang, Li-jian; Yang, Yue
2012-04-01
To investigate the diagnostic accuracy of needle puncture biopsy and pathological examination of frozen during operation for pulmonary nodules, and whether this diagnostic method can replace tumor resection examination. Totally 50 patients (28 males and 22 females, average age was 59 years) who had the single nodule after imaging examination without any pathological diagnostic from January to October 2010 were selected in this research work. During open operation or video assisted thoracic surgery, needle (14 G model) was used to puncture biopsy for pathological examination of frozen. All the adverse events during puncture biopsy would be recorded. The resection specimens would be accepted paraffin pathological examination. The relationship between puncture frozen pathological and paraffin pathological examination was analyzed. All tumor sizes were ranged from 1.0 cm × 0.6 cm to 5.6 cm × 9.0 cm. The paraffin pathological examination after operation as the golden standard, there were 7 cases of benign tumor and 43 cases of malignant tumor. The diagnostic sensitivity of puncture biopsy was 90.7%, the specificity was 100%, the positive predictive value was 100% and the negative predictive value was 63.6%. There were 11 cases of benign tumor diagnosed by needle puncture biopsy, among which 4 cases were proved as malignant tumor by paraffin pathology, and the false negative rate was 9.3%. The main risk of puncture biopsy was bleeding after puncture immediately, and the rate was 4.0% (2/50). The puncture biopsy during operation had a high specificity for malignant lung tumor, and there was a certain false negative rate for benign tumor. Puncture biopsy and pathological examination of frozen tissue can replace tumor section biopsy in a way.
Fanfani, Francesco; Monterossi, Giorgia; Ghizzoni, Viola; Rossi, Esther D; Dinoi, Giorgia; Inzani, Frediano; Fagotti, Anna; Gueli Alletti, Salvatore; Scarpellini, Francesca; Nero, Camilla; Santoro, Angela; Scambia, Giovanni; Zannoni, Gian F
2018-01-01
The aim of the current study is to evaluate the detection rate of micro- and macro-metastases of the One-Step Nucleic Acid Amplification (OSNA) compared to frozen section examination and subsequent ultra-staging examination in early stage endometrial cancer (EC). From March 2016 to June 2016, data of 40 consecutive FIGO stage I EC patients were prospectively collected in an electronic database. The sentinel lymph node mapping was performed in all patients. All mapped nodes were removed and processed. Sentinel lymph nodes were sectioned and alternate sections were respectively examined by OSNA and by frozen section analysis. After frozen section, the residual tissue from each block was processed with step-level sections (each step at 200 micron) including H&E and IHC slides. Sentinel lymph nodes mapping was successful in 29 patients (72.5%). In the remaining 11 patients (27.5%), a systematic pelvic lymphadenectomy was performed. OSNA assay sensitivity and specificity were 87.5% and 100% respectively. Positive and negative predictive values were 100% and 99% respectively, with a diagnostic accuracy of 99%. As far as frozen section examination and subsequent ultra-staging analysis was concerned, we reported sensitivity and specificity of 50% and 94.4% respectively; positive and negative predictive values were 14.3% and 99%, respectively, with an accuracy of 93.6%. In one patient, despite negative OSNA and frozen section analysis of the sentinel node, a macro-metastasis in 1 non-sentinel node was found. The combination of OSNA procedure with the sentinel lymph node mapping could represent an efficient intra-operative tool for the selection of early-stage EC patients to be submitted to systematic lymphadenectomy.
Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan
2017-01-01
Abstract Background. The performance of Plasmodium falciparum–specific histidine-rich protein 2–based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Methods. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2–based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. Results. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. Conclusions. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. PMID:28369268
Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan; Hsiang, Michelle S
2017-05-01
The performance of Plasmodium falciparum-specific histidine-rich protein 2-based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2-based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Clinical Scales Do Not Reliably Identify Acute Ischemic Stroke Patients With Large-Artery Occlusion.
Turc, Guillaume; Maïer, Benjamin; Naggara, Olivier; Seners, Pierre; Isabel, Clothilde; Tisserand, Marie; Raynouard, Igor; Edjlali, Myriam; Calvet, David; Baron, Jean-Claude; Mas, Jean-Louis; Oppenheim, Catherine
2016-06-01
It remains debated whether clinical scores can help identify acute ischemic stroke patients with large-artery occlusion and hence improve triage in the era of thrombectomy. We aimed to determine the accuracy of published clinical scores to predict large-artery occlusion. We assessed the performance of 13 clinical scores to predict large-artery occlusion in consecutive patients with acute ischemic stroke undergoing clinical examination and magnetic resonance or computed tomographic angiography ≤6 hours of symptom onset. When no cutoff was published, we used the cutoff maximizing the sum of sensitivity and specificity in our cohort. We also determined, for each score, the cutoff associated with a false-negative rate ≤10%. Of 1004 patients (median National Institute of Health Stroke Scale score, 7; range, 0-40), 328 (32.7%) had an occlusion of the internal carotid artery, M1 segment of the middle cerebral artery, or basilar artery. The highest accuracy (79%; 95% confidence interval, 77-82) was observed for National Institute of Health Stroke Scale score ≥11 and Rapid Arterial Occlusion Evaluation Scale score ≥5. However, these cutoffs were associated with false-negative rates >25%. Cutoffs associated with an false-negative rate ≤10% were 5, 1, and 0 for National Institute of Health Stroke Scale, Rapid Arterial Occlusion Evaluation Scale, and Cincinnati Prehospital Stroke Severity Scale, respectively. Using published cutoffs for triage would result in a loss of opportunity for ≥20% of patients with large-artery occlusion who would be inappropriately sent to a center lacking neurointerventional facilities. Conversely, using cutoffs reducing the false-negative rate to 10% would result in sending almost every patient to a comprehensive stroke center. Our findings, therefore, suggest that intracranial arterial imaging should be performed in all patients with acute ischemic stroke presenting within 6 hours of symptom onset. © 2016 American Heart Association, Inc.
Evaluating the accuracy of SHAPE-directed RNA secondary structure predictions
Sükösd, Zsuzsanna; Swenson, M. Shel; Kjems, Jørgen; Heitsch, Christine E.
2013-01-01
Recent advances in RNA structure determination include using data from high-throughput probing experiments to improve thermodynamic prediction accuracy. We evaluate the extent and nature of improvements in data-directed predictions for a diverse set of 16S/18S ribosomal sequences using a stochastic model of experimental SHAPE data. The average accuracy for 1000 data-directed predictions always improves over the original minimum free energy (MFE) structure. However, the amount of improvement varies with the sequence, exhibiting a correlation with MFE accuracy. Further analysis of this correlation shows that accurate MFE base pairs are typically preserved in a data-directed prediction, whereas inaccurate ones are not. Thus, the positive predictive value of common base pairs is consistently higher than the directed prediction accuracy. Finally, we confirm sequence dependencies in the directability of thermodynamic predictions and investigate the potential for greater accuracy improvements in the worst performing test sequence. PMID:23325843
Morotti, Andrea; Jessel, Michael J; Brouwers, H Bart; Falcone, Guido J; Schwab, Kristin; Ayres, Alison M; Vashkevich, Anastasia; Anderson, Christopher D; Viswanathan, Anand; Greenberg, Steven M; Gurol, M Edip; Romero, Javier M; Rosand, Jonathan; Goldstein, Joshua N
2016-08-01
The computed tomography angiography (CTA) spot sign is a validated predictor of hematoma expansion and poor outcome in supratentorial intracerebral hemorrhage (ICH), but patients with brainstem ICH have typically been excluded from the analyses. We investigated the frequency of spot sign and its relationship with hematoma expansion and outcome in patients with primary pontine hemorrhage (PPH). We performed a retrospective analysis of PPH cases obtained from a prospectively collected cohort of consecutive ICH patients who underwent CTA. CTA first-pass readings for spot sign presence were analyzed by two trained readers. Baseline and follow-up hematoma volumes on non-contrast CT scans were assessed by semi-automated computer-assisted volumetric analysis. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive and negative likelihood ratio, and accuracy of spot sign for prediction of in-hospital mortality were calculated. 49 subjects met the inclusion criteria of whom 11 (22.4 %) showed a spot sign. In-hospital mortality was higher in spot sign-positive versus spot sign-negative subjects (90.9 vs 47.4 %, p = 0.020). Spot sign showed excellent specificity (95 %) and PPV (91 %) in predicting in-hospital mortality. Absolute hematoma growth, defined as parenchymal and intraventricular hematoma expansion of any amount, was significantly higher in spot sign-positive versus spot sign-negative subjects (13.72 ± 20.93 vs 3.76 ± 8.55 mL, p = 0.045). As with supratentorial ICH, the CTA spot sign is a common finding and is associated with higher risk of hematoma expansion and mortality in PPH. This marker may assist clinicians in prognostic stratification.
Distinct mechanisms for the impact of distraction and interruption on working memory in aging
Clapp, Wesley C; Gazzaley, Adam
2010-01-01
Interference is known to negatively impact the ability to maintain information in working memory (WM), an effect that is exacerbated with aging. Here, we explore how distinct sources of interference, i.e., distraction (stimuli to-be-ignored) and interruption (stimuli requiring attention), differentially influence WM in younger and older adults. EEG was recorded while participants engaged in three versions of a delayed-recognition task: no interference, a distracting stimulus, and an interrupting stimulus presented during WM maintenance. Behaviorally, both types of interference negatively impacted WM accuracy in older adults significantly more than younger adults (with a larger deficit for interruptions). N170 latency measures revealed that the degree of processing both distractors and interruptors predicted WM accuracy in both populations. However, while WM impairments could be explained by excessive attention to distractors by older adults (a suppression deficit), impairment induced by interruption were not clearly mediated by age-related increases in attention to interruptors. These results suggest that distinct underlying mechanisms mediate the impact of different types of external interference on WM in normal aging. PMID:20144492
López-Gil, Norberto; Fernández-Sánchez, Vicente; Thibos, Larry N.; Montés-Micó, Robert
2010-01-01
Purpose We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied from 0.2 to 1.1 D depending on the method. The precision in this prediction also varied between subjects, with an average standard error of the mean of 0.1 D that decreased with age. Conclusions Depth of field increases subjective of amplitude of accommodation overestimating the objective amplitude obtained with all the metrics used. The change in the negative direction of spherical aberration during accommodation increases the amplitude of accommodation by an amount that varies with age.
Predictive model of outcome of targeted nodal assessment in colorectal cancer.
Nissan, Aviram; Protic, Mladjan; Bilchik, Anton; Eberhardt, John; Peoples, George E; Stojadinovic, Alexander
2010-02-01
Improvement in staging accuracy is the principal aim of targeted nodal assessment in colorectal carcinoma. Technical factors independently predictive of false negative (FN) sentinel lymph node (SLN) mapping should be identified to facilitate operative decision making. To define independent predictors of FN SLN mapping and to develop a predictive model that could support surgical decisions. Data was analyzed from 2 completed prospective clinical trials involving 278 patients with colorectal carcinoma undergoing SLN mapping. Clinical outcome of interest was FN SLN(s), defined as one(s) with no apparent tumor cells in the presence of non-SLN metastases. To assess the independent predictive effect of a covariate for a nominal response (FN SLN), a logistic regression model was constructed and parameters estimated using maximum likelihood. A probabilistic Bayesian model was also trained and cross validated using 10-fold train-and-test sets to predict FN SLN mapping. Area under the curve (AUC) from receiver operating characteristics curves of these predictions was calculated to determine the predictive value of the model. Number of SLNs (<3; P = 0.03) and tumor-replaced nodes (P < 0.01) independently predicted FN SLN. Cross validation of the model created with Bayesian Network Analysis effectively predicted FN SLN (area under the curve = 0.84-0.86). The positive and negative predictive values of the model are 83% and 97%, respectively. This study supports a minimum threshold of 3 nodes for targeted nodal assessment in colorectal cancer, and establishes sufficient basis to conclude that SLN mapping and biopsy cannot be justified in the presence of clinically apparent tumor-replaced nodes.
A Hybrid Remote Sensing Approach for Detecting the Florida Red Tide
NASA Astrophysics Data System (ADS)
Carvalho, G. A.; Minnett, P. J.; Banzon, V.; Baringer, W.
2008-12-01
Harmful algal blooms (HABs) have caused major worldwide economic losses commonly linked with health problems for humans and wildlife. In the Eastern Gulf of Mexico the toxic marine dinoflagellate Karenia brevis is responsible for nearly annual, massive red tides causing fish kills, shellfish poisoning, and acute respiratory irritation in humans: the so-called Florida Red Tide. Near real-time satellite measurements could be an effective method for identifying HABs. The use of space-borne data would be a highly desired, low-cost technique offering the remote and accurate detection of K. brevis blooms over the West Florida Shelf, bringing tremendous societal benefits to the general public, scientific community, resource managers and medical health practitioners. An extensive in situ database provided by the Florida Fish and Wildlife Conservation Commission's Research Institute was used to examine the long-term accuracy of two satellite- based algorithms at detecting the Florida Red Tide. Using MODIS data from 2002 to 2006, the two algorithms are optimized and their accuracy assessed. It has been found that the sequential application of the algorithms results in improved predictability characteristics, correctly identifying ~80% of the cases (for both sensitivity and specificity, as well as overall accuracy), and exhibiting strong positive (70%) and negative (86%) predictive values.
An interactive dynamic analysis and decision support software for MR mammography.
Ertaş, Gökhan; Gülçür, H Ozcan; Tunaci, Mehtap
2008-06-01
A fully automated software is introduced to facilitate MR mammography (MRM) examinations and overcome subjectiveness in diagnosis using normalized maximum intensity-time ratio (nMITR) maps. These maps inherently suppress enhancements due to normal parenchyma and blood vessels that surround lesions and have natural tolerance to small field inhomogeneities and motion artifacts. The classifier embedded within the software is trained with normalized complexity and maximum nMITR of 22 lesions and tested with the features of remaining 22 lesions. Achieved diagnostic performances are 92% sensitivity, 90% specificity, 91% accuracy, 92% positive predictive value and 90% negative predictive value. DynaMammoAnalyst shortens evaluation time considerably and reduces inter and intra-observer variability by providing decision support.
Conser, Christiana; Seebacher, Lizbeth; Fujino, David W; Reichard, Sarah; DiTomaso, Joseph M
2015-01-01
Weed Risk Assessment (WRA) methods for evaluating invasiveness in plants have evolved rapidly in the last two decades. Many WRA tools exist, but none were specifically designed to screen ornamental plants prior to being released into the environment. To be accepted as a tool to evaluate ornamental plants for the nursery industry, it is critical that a WRA tool accurately predicts non-invasiveness without falsely categorizing them as invasive. We developed a new Plant Risk Evaluation (PRE) tool for ornamental plants. The 19 questions in the final PRE tool were narrowed down from 56 original questions from existing WRA tools. We evaluated the 56 WRA questions by screening 21 known invasive and 14 known non-invasive ornamental plants. After statistically comparing the predictability of each question and the frequency the question could be answered for both invasive and non-invasive species, we eliminated questions that provided no predictive power, were irrelevant in our current model, or could not be answered reliably at a high enough percentage. We also combined many similar questions. The final 19 remaining PRE questions were further tested for accuracy using 56 additional known invasive plants and 36 known non-invasive ornamental species. The resulting evaluation demonstrated that when "needs further evaluation" classifications were not included, the accuracy of the model was 100% for both predicting invasiveness and non-invasiveness. When "needs further evaluation" classifications were included as either false positive or false negative, the model was still 93% accurate in predicting invasiveness and 97% accurate in predicting non-invasiveness, with an overall accuracy of 95%. We conclude that the PRE tool should not only provide growers with a method to accurately screen their current stock and potential new introductions, but also increase the probability of the tool being accepted for use by the industry as the basis for a nursery certification program.
Conser, Christiana; Seebacher, Lizbeth; Fujino, David W.; Reichard, Sarah; DiTomaso, Joseph M.
2015-01-01
Weed Risk Assessment (WRA) methods for evaluating invasiveness in plants have evolved rapidly in the last two decades. Many WRA tools exist, but none were specifically designed to screen ornamental plants prior to being released into the environment. To be accepted as a tool to evaluate ornamental plants for the nursery industry, it is critical that a WRA tool accurately predicts non-invasiveness without falsely categorizing them as invasive. We developed a new Plant Risk Evaluation (PRE) tool for ornamental plants. The 19 questions in the final PRE tool were narrowed down from 56 original questions from existing WRA tools. We evaluated the 56 WRA questions by screening 21 known invasive and 14 known non-invasive ornamental plants. After statistically comparing the predictability of each question and the frequency the question could be answered for both invasive and non-invasive species, we eliminated questions that provided no predictive power, were irrelevant in our current model, or could not be answered reliably at a high enough percentage. We also combined many similar questions. The final 19 remaining PRE questions were further tested for accuracy using 56 additional known invasive plants and 36 known non-invasive ornamental species. The resulting evaluation demonstrated that when “needs further evaluation” classifications were not included, the accuracy of the model was 100% for both predicting invasiveness and non-invasiveness. When “needs further evaluation” classifications were included as either false positive or false negative, the model was still 93% accurate in predicting invasiveness and 97% accurate in predicting non-invasiveness, with an overall accuracy of 95%. We conclude that the PRE tool should not only provide growers with a method to accurately screen their current stock and potential new introductions, but also increase the probability of the tool being accepted for use by the industry as the basis for a nursery certification program. PMID:25803830
Oshida, Sotaro; Ogasawara, Kuniaki; Saura, Hiroaki; Yoshida, Koji; Fujiwara, Shunro; Kojima, Daigo; Kobayashi, Masakazu; Yoshida, Kenji; Kubo, Yoshitaka; Ogawa, Akira
2015-01-01
The purpose of the present study was to determine whether preoperative measurement of cerebral blood flow (CBF) with acetazolamide in addition to preoperative measurement of CBF at the resting state increases the predictive accuracy of development of cerebral hyperperfusion after carotid endarterectomy (CEA). CBF at the resting state and cerebrovascular reactivity (CVR) to acetazolamide were quantitatively assessed using N-isopropyl-p-[(123)I]-iodoamphetamine (IMP)-autoradiography method with single-photon emission computed tomography (SPECT) before CEA in 500 patients with ipsilateral internal carotid artery stenosis (≥ 70%). CBF measurement using (123)I-IMP SPECT was also performed immediately and 3 days after CEA. A region of interest (ROI) was automatically placed in the middle cerebral artery territory in the affected cerebral hemisphere using a three-dimensional stereotactic ROI template. Preoperative decreases in CBF at the resting state [95% confidence intervals (CIs), 0.855 to 0.967; P = 0.0023] and preoperative decreases in CVR to acetazolamide (95% CIs, 0.844 to 0.912; P < 0.0001) were significant independent predictors of post-CEA hyperperfusion. The area under the receiver operating characteristic curve for prediction of the development of post-CEA hyperperfusion was significantly greater for CVR to acetazolamide than for CBF at the resting state (difference between areas, 0.173; P < 0.0001). Sensitivity, specificity, and positive- and negative-predictive values for the prediction of the development of post-CEA hyperperfusion were significantly greater for CVR to acetazolamide than for CBF at the resting state (P < 0.05, respectively). The present study demonstrated that preoperative measurement of CBF with acetazolamide in addition to preoperative measurement of CBF at the resting state increases the predictive accuracy of the development of post-CEA hyperperfusion.
[Sequential monitoring of renal transplant with aspiration cytology].
Manfro, R C; Gonçalves, L F; de Moura, L A
1998-01-01
To evaluate the utility of kidney aspiration cytology in the sequential monitorization of acute rejection in renal transplant patients. Thirty patients were submitted to 376 aspirations. The clinical diagnoses were independently established. The representativity of the samples reached 82.7%. The total corrected increment index and the number of immunoactivated cells were higher during acute rejection as compared to normal allograft function, acute tubular necrosis, and cyclosporine nephrotoxicity. The parameters to the diagnosis of acute rejection were sensitivity: 71.8%, specificity: 87.3%, positive predictive value: 50.9%, negative predictive value: 94.9% and accuracy 84.9%. The false positive results were mainly related to cytomegalovirus infection or to the administration of OKT3. In 10 out of 11 false negative results incipient immunoactivation was present alerting to the possibility of acute rejection. Kidney aspiration cytology is a useful tool for the sequential monitorization of acute rejection in renal transplant patients. The best results are reached when the results of aspiration cytology are analyzed with the clinical data.
Tamir, Maya; Robinson, Michael D; Solberg, Emily Crawford
2006-10-01
The present studies sought to investigate the hedonic consequences of threat-identification skills at low and high levels of neuroticism. Such skills were assessed in terms of both speed (Study 1) and accuracy (Study 2) of identifying threatening objects in cognitive tasks. As predicted, threat-identification skills interacted with trait neuroticism in predicting subjective experiences. Specifically, individuals high in neuroticism experienced lower levels of negative affect during their everyday lives if they were also skilled in identifying threats in the cognitive tasks (Studies 1-2). Such skills did not matter at low levels of neuroticism. This interactive pattern was also replicated in the context of life domain satisfaction (Study 2). The results support the view that avoidance motivation encompasses multiple component processes, including some that are cognitive in nature, and specifically extends self-regulatory views of neuroticism. Of most importance, our data indicate that threat-identification skills can be hedonically beneficial, rather than costly, at high levels of neuroticism.
Potente, Giuseppe; Messineo, Daniela; Maggi, Claudia; Savelli, Sara
2009-03-01
The purpose of this article is to report our practical utilization of dynamic contrast-enhanced magnetic resonance mammography [DCE-MRM] in the diagnosis of breast lesions. In many European centers, was preferred a high-temporal acquisition of both breasts simultaneously in a large FOV. We preferred to scan single breasts, with the aim to combine the analysis of the contrast intake and washout with the morphological evaluation of breast lesions. We followed an interpretation model, based upon a diagnostic algorithm, which combined contrast enhancement with morphological evaluation, in order to increase our confidence in diagnosis. DCE-MRM with our diagnostic algorithm has identified 179 malignant and 41 benign lesions; final outcome has identified 178 malignant and 42 benign lesions, 3 false positives and 2 false negatives. Sensitivity of CE-MRM was 98.3%; specificity, 95.1%; positive predictive value, 98.9%; negative predictive value, 92.8% and accuracy, 97.7%.
Rakotoarivelo, R; Ambrosioni, J; Rasolofo, V; Raberahona, M; Rakotosamimanana, N; Andrianasolo, R; Ramanampamonjy, R; Tiaray, M; Razafimahefa, J; Rakotoson, J; Randria, M; Bonnet, F; Calmy, A
2018-04-01
To evaluate the feasibility of the implementation of a commercial rapid molecular diagnostic test (Xpert MTB/RIF) for the routine diagnosis of smear-negative or extrapulmonary tuberculosis (TB) and its diagnostic accuracy, and to assess HIV prevalence in a real-life setting in Madagascar. This study was set in a tertiary care hospital in Madagascar. A prospective cohort study was conducted of all consecutive cases with suspected smear-negative and/or extrapulmonary TB over a 2-year period. Cases were classified as proven, probable, or possible TB cases, or as having an alternative diagnosis. Of the 363 patients included, 183 (50.4%) had suspected smear-negative pulmonary TB and 180 (49.6%) had suspected extrapulmonary TB. For proven cases, the sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF were 82.4%, 98.8%, 98.3%, and 86.6%, respectively; for proven and probable cases grouped together, these values were 65%, 98.8%, 98.5%, and 64%, respectively. The diagnostic accuracy was slightly lower for extrapulmonary TB compared to smear-negative pulmonary TB. The prevalence of HIV infection was 12.1%, but almost half of these cases did not have TB (alternative diagnosis group). The implementation of a rapid diagnosis programme for TB in a resource-poor setting is feasible. The performance of the Xpert-MTB/RIF was remarkable in this difficult-to-diagnose population. HIV prevalence in this study was much higher than the prevalence reported in the general population in Madagascar, in patients with TB and patients with conditions other than TB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
How Do Negative Emotions Impair Self-Control? A Neural Model of Negative Urgency
Chester, David S.; Lynam, Donald R.; Milich, Richard; Powell, David K.; Andersen, Anders H.; DeWall, C. Nathan
2016-01-01
Self-control often fails when people experience negative emotions. Negative urgency represents the dispositional tendency to experience such self-control failure in response to negative affect. The neural underpinnings of negative urgency are not fully understood, nor is the more general phenomenon of self-control failure in response to negative emotions. Previous theorizing suggests that an insufficient, inhibitory response from the prefrontal cortex may be the culprit behind such self-control failure. However, we entertained an alternative hypothesis: negative emotions lead to self-control failure because they excessively tax inhibitory regions of the prefrontal cortex. Using fMRI, we compared the neural activity of people high in negative urgency with controls on an emotional, inhibitory Go/No-Go task. While experiencing negative (but not positive or neutral) emotions, participants high in negative urgency showed greater recruitment of inhibitory brain regions than controls. Suggesting a compensatory function, inhibitory accuracy among participants high in negative urgency was associated with greater prefrontal recruitment. Greater activity in the anterior insula on negatively-valenced, inhibitory trials predicted greater substance abuse one month and one year after the MRI scan among individuals high in negative urgency. These results suggest that, among people whose negative emotions often lead to self-control failure, excessive reactivity of the brain’s regulatory resources may be the culprit. PMID:26892861
Affective processes in human-automation interactions.
Merritt, Stephanie M
2011-08-01
This study contributes to the literature on automation reliance by illuminating the influences of user moods and emotions on reliance on automated systems. Past work has focused predominantly on cognitive and attitudinal variables, such as perceived machine reliability and trust. However, recent work on human decision making suggests that affective variables (i.e., moods and emotions) are also important. Drawing from the affect infusion model, significant effects of affect are hypothesized. Furthermore, a new affectively laden attitude termed liking is introduced. Participants watched video clips selected to induce positive or negative moods, then interacted with a fictitious automated system on an X-ray screening task At five time points, important variables were assessed including trust, liking, perceived machine accuracy, user self-perceived accuracy, and reliance.These variables, along with propensity to trust machines and state affect, were integrated in a structural equation model. Happiness significantly increased trust and liking for the system throughout the task. Liking was the only variable that significantly predicted reliance early in the task. Trust predicted reliance later in the task, whereas perceived machine accuracy and user self-perceived accuracy had no significant direct effects on reliance at any time. Affective influences on automation reliance are demonstrated, suggesting that this decision-making process may be less rational and more emotional than previously acknowledged. Liking for a new system may be key to appropriate reliance, particularly early in the task. Positive affect can be easily induced and may be a lever for increasing liking.
Lima, Fabricio O; Silva, Gisele S; Furie, Karen L; Frankel, Michael R; Lev, Michael H; Camargo, Érica C S; Haussen, Diogo C; Singhal, Aneesh B; Koroshetz, Walter J; Smith, Wade S; Nogueira, Raul G
2016-08-01
Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. The Field Assessment Stroke Triage for Emergency Destination (FAST-ED) scale was based on items of the National Institutes of Health Stroke Scale (NIHSS) with higher predictive value for LVOS and tested in the Screening Technology and Outcomes Project in Stroke (STOPStroke) cohort, in which patients underwent computed tomographic angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial internal carotid artery, middle cerebral artery-M1, middle cerebral artery-2, or basilar arteries. Patients with partial, bihemispheric, and anterior+posterior circulation occlusions were excluded. Receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value of FAST-ED were compared with the NIHSS, Rapid Arterial Occlusion Evaluation (RACE) scale, and Cincinnati Prehospital Stroke Severity (CPSS) scale. LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the receiver operating characteristic curve: FAST-ED=0.81 as reference; NIHSS=0.80, P=0.28; RACE=0.77, P=0.02; and CPSS=0.75, P=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity of 0.89, positive predictive value of 0.72, and negative predictive value of 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, and 0.79, and CPSS ≥2 of 0.56, 0.85, 0.65, and 0.78, respectively. FAST-ED is a simple scale that if successfully validated in the field, it may be used by medical emergency professionals to identify LVOS in the prehospital setting enabling rapid triage of patients. © 2016 American Heart Association, Inc.
Rathnakar, Surag Kajoor; Vishnu, Vikram Hubbanageri; Muniyappa, Shridhar; Prasath, Arun
2017-02-01
Acute Pancreatitis (AP) is one of the common conditions encountered in the emergency room. The course of the disease ranges from mild form to severe acute form. Most of these episodes are mild and spontaneously subsiding within 3 to 5 days. In contrast, Severe Acute Pancreatitis (SAP) occurring in around 15-20% of all cases, mortality can range between 10 to 85% across various centres and countries. In such a situation we need an indicator which can predict the outcome of an attack, as severe or mild, as early as possible and such an indicator should be sensitive and specific enough to trust upon. PANC-3 scoring is such a scoring system in predicting the outcome of an attack of AP. To assess the accuracy and predictability of PANC-3 scoring system over APACHE II in predicting severity in an attack of AP. This prospective study was conducted on 82 patients admitted with the diagnosis of pancreatitis. Investigations to evaluate PANC-3 and APACHE II were done on all the patients and the PANC-3 and APACHE II score was calculated. PANC-3 score has a sensitivity of 82.6% and specificity of 77.9%, the test had a Positive Predictive Value (PPV) of 0.59 and Negative Predictive Value (NPV) of 0.92. Sensitivity of APACHE II in predicting SAP was 91.3% and specificity was 96.6% with PPV of 0.91, NPV was 0.96. Our study shows that PANC-3 can be used to predict the severity of pancreatitis as efficiently as APACHE II. The interpretation of PANC-3 does not need expertise and can be applied at the time of admission which is an advantage when compared to classical scoring systems.
A support vector machine for predicting defibrillation outcomes from waveform metrics.
Howe, Andrew; Escalona, Omar J; Di Maio, Rebecca; Massot, Bertrand; Cromie, Nick A; Darragh, Karen M; Adgey, Jennifer; McEneaney, David J
2014-03-01
Algorithms to predict shock success based on VF waveform metrics could significantly enhance resuscitation by optimising the timing of defibrillation. To investigate robust methods of predicting defibrillation success in VF cardiac arrest patients, by using a support vector machine (SVM) optimisation approach. Frequency-domain (AMSA, dominant frequency and median frequency) and time-domain (slope and RMS amplitude) VF waveform metrics were calculated in a 4.1Y window prior to defibrillation. Conventional prediction test validity of each waveform parameter was conducted and used AUC>0.6 as the criterion for inclusion as a corroborative attribute processed by the SVM classification model. The latter used a Gaussian radial-basis-function (RBF) kernel and the error penalty factor C was fixed to 1. A two-fold cross-validation resampling technique was employed. A total of 41 patients had 115 defibrillation instances. AMSA, slope and RMS waveform metrics performed test validation with AUC>0.6 for predicting termination of VF and return-to-organised rhythm. Predictive accuracy of the optimised SVM design for termination of VF was 81.9% (± 1.24 SD); positive and negative predictivity were respectively 84.3% (± 1.98 SD) and 77.4% (± 1.24 SD); sensitivity and specificity were 87.6% (± 2.69 SD) and 71.6% (± 9.38 SD) respectively. AMSA, slope and RMS were the best VF waveform frequency-time parameters predictors of termination of VF according to test validity assessment. This a priori can be used for a simplified SVM optimised design that combines the predictive attributes of these VF waveform metrics for improved prediction accuracy and generalisation performance without requiring the definition of any threshold value on waveform metrics. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Yu, Zhiyuan; Zheng, Jun; Ma, Lu; Guo, Rui; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao
2017-09-01
In patients with spontaneous intracerebral hemorrhage (sICH), hematoma expansion (HE) is associated with poor outcome. Spot sign and black hole sign are neuroimaging predictors for HE. This study was aimed to compare the predictive value of two signs for HE. Within 6 h after onset of sICH, patients were screened for the computed tomography angiography spot sign and the non-contrast computed tomography black hole sign. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of two signs for HE prediction were calculated. The accuracy of two signs in predicting HE was analyzed by receiver-operator analysis. A total of 129 patients were included in this study. Spot sign was identified in 30 (23.3%) patients and black hole sign in 29 (22.5%) patients, respectively. Of 32 patients with HE, spot sign was observed in 19 (59.4%) and black hole sign was found in 14 (43.8%). The occurrence of black hole sign was significantly associated with spot sign (P < 0.001). The sensitivity, specificity, PPV, and NPV of spot sign for predicting HE were 59.38, 88.66, 63.33, and 86.87% respectively. In contrast, the sensitivity, specificity, PPV, and NPV of black hole sign for predicting HE were 43.75, 84.54, 48.28, and 82.00%, respectively. The area under the curve was 0.740 for spot sign and 0.641 for black hole sign. (P = 0.228) Both spot sign and black hole sign appeared to have good predictive value for HE, and spot sign seemed to be a better predictor.
Diagnostic performance of labial minor salivary gland flow measurement for assessment of xerostomia.
Satoh-Kuriwada, Shizuko; Iikubo, Masahiro; Shoji, Noriaki; Sakamoto, Maya; Sasano, Takashi
2012-08-01
Minor salivary gland flow rate (MF) has been proposed as a key feature of xerostomia (subjective feeling of dry mouth). To assess its diagnostic performance, MF was compared in xerostomia and control subjects. Sixty-six subjects with xerostomia and 30 controls were enrolled. MF was measured in the lower labial mucosa using the iodine-starch filter paper method. Stimulated whole salivary flow rates were also measured using the gum test (stimulated-WF). Both labial-MF and stimulated-WF were significantly lower in xerostomia subjects than in controls. There was a positive correlation between labial-MF and stimulated-WF in control but not xerostomia subjects. In xerostomia subjects compared to controls, there was a significantly larger reduction in labial-MF than in stimulated-WF. Xerostomia was most accurately diagnosed using a labial-MF cutoff value of 0.25 μL/cm(2)/min. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy at this cutoff value were 1.00, 0.87, 0.93, 1.00, and 0.96, respectively. Compared to respective values of 0.64, 1.00, 1.00, 0.56, and 0.75 for stimulated-WF at the traditional cutoff of 1.0 mL/min, these data indicate the higher sensitivity, negative predictive value, and diagnostic accuracy of labial-MF. Xerostomia was more strongly related to reduction of labial-MF than to that of stimulated-WF. Xerostomia was most likely triggered at a labial-MF cut-off value of 0.25 μL/cm(2)/min based on results from the iodine-starch method. Copyright © 2012 Elsevier Ltd. All rights reserved.
Ponce, Camille; Kaczorowski, Flora; Perpoint, Thomas; Miailhes, Patrick; Sigal, Alain; Javouhey, Etienne; Gillet, Yves; Jacquin, Laurent; Douplat, Marion; Tazarourte, Karim; Potinet, Véronique; Simon, Bruno; Lavoignat, Adeline; Bonnot, Guillaume; Sow, Fatimata; Bienvenu, Anne-Lise; Picot, Stéphane
2017-01-01
Background: Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. Results: 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. Conclusion: High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method. PMID:29251261
Rossi, Esther Diana; Bizzarro, Tommaso; Schmitt, Fernando; Longatto-Filho, Adhemar
2015-04-01
Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility. © 2015 American Cancer Society.
Influence of cone beam CT enhancement filters on diagnosis ability of longitudinal root fractures
Nascimento, M C C; Nejaim, Y; de Almeida, S M; Bóscolo, F N; Haiter-Neto, F; Sobrinho, L C
2014-01-01
Objectives: To determine whether cone beam CT (CBCT) enhancement filters influence the diagnosis of longitudinal root fractures. Methods: 40 extracted human posterior teeth were endodontically prepared, and fractures with no separation of fragments were made in 20 teeth of this sample. The teeth were placed in a dry mandible and scanned using a Classic i-CAT® CBCT device (Imaging Sciences International, Inc., Hatfield, PA). Evaluations were performed with and without CBCT filters (Sharpen Mild, Sharpen Super Mild, S9, Sharpen, Sharpen 3 × 3, Angio Sharpen Medium 5 × 5, Angio Sharpen High 5 × 5 and Shadow 3 × 3) by three oral radiologists. Inter- and intraobserver agreement was calculated by the kappa test. Accuracy, sensitivity, specificity and positive and negative predictive values were determined. McNemar test was applied for agreement between all images vs the gold standard and original images vs images with filters (p < 0.05). Results: Means of intraobserver agreement ranged from good to excellent. Angio Sharpen Medium 5 × 5 filter obtained the highest positive predictive value (80.0%) and specificity value (76.5%). Angio Sharpen High 5 × 5 filter obtained the highest sensitivity (78.9%) and accuracy (77.5%) value. Negative predictive value was the highest (82.9%) for S9 filter. The McNemar test showed no statistically significant differences between images with and without CBCT filters (p > 0.05). Conclusions: Although no statistical differences was observed in the diagnosis of root fractures when using filters, these filters seem to improve diagnostic capacity for longitudinal root fractures. Further in vitro studies with endodontic-treated teeth and research in vivo should be considered. PMID:24408819
Zhao, Xiaowei; Ning, Qiao; Chai, Haiting; Ma, Zhiqiang
2015-06-07
As a widespread type of protein post-translational modifications (PTMs), succinylation plays an important role in regulating protein conformation, function and physicochemical properties. Compared with the labor-intensive and time-consuming experimental approaches, computational predictions of succinylation sites are much desirable due to their convenient and fast speed. Currently, numerous computational models have been developed to identify PTMs sites through various types of two-class machine learning algorithms. These methods require both positive and negative samples for training. However, designation of the negative samples of PTMs was difficult and if it is not properly done can affect the performance of computational models dramatically. So that in this work, we implemented the first application of positive samples only learning (PSoL) algorithm to succinylation sites prediction problem, which was a special class of semi-supervised machine learning that used positive samples and unlabeled samples to train the model. Meanwhile, we proposed a novel succinylation sites computational predictor called SucPred (succinylation site predictor) by using multiple feature encoding schemes. Promising results were obtained by the SucPred predictor with an accuracy of 88.65% using 5-fold cross validation on the training dataset and an accuracy of 84.40% on the independent testing dataset, which demonstrated that the positive samples only learning algorithm presented here was particularly useful for identification of protein succinylation sites. Besides, the positive samples only learning algorithm can be applied to build predictors for other types of PTMs sites with ease. A web server for predicting succinylation sites was developed and was freely accessible at http://59.73.198.144:8088/SucPred/. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lao, Annabelle Y; Sharma, Vijay K; Tsivgoulis, Georgios; Frey, James L; Malkoff, Marc D; Navarro, Jose C; Alexandrov, Andrei V
2008-10-01
International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.
Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri
2017-11-01
- Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.
Sánchez-Villalobos, Alfredo; Urdaneta-Fernández, Margelys; Rubio-Fuenmayor, Elí; Molero-Saras, Gladys; Luzardo-Charris, Carlos; Corona-Mengual, Carlos
2011-03-01
In order to show the development and scope of a serological analysis method based on fluorescence polarization assay (FPA) from a drop of blood obtained by the capillary technique, a Brucella antibody assay was performed on a group of 321 high-risk workers. The results were compared with data from the analysis of blood serum by FPA and a competitive enzyme immunoassay (ELISA-c). The number of concordance was 318 (99.06%), and discordant 3 (0.93%), which were negative in serum by fluorescence polarization (FPAs) and ELISA-c, but positive with capillary FPA (FPAc). The comparative results FPAc were: sensitivity 100%; specificity: 99.05%; positive predictive value 66.67%; negative predictive value 100.0%; false positive rate: 0.95%; false negative rate: 0%; accuracy: 98.0%; odds ratio: 203.00. The youden J for both FPA methods was 0.667. The identification was considered reliable and the correlation of both procedures, FPA and ELISA-c, was no statistically different (P > 0.05%), which allows to highly recommend the study implementation of human brucellosis with capillary blood as a preliminary method.
Hoerger, Michael; Quirk, Stuart W.; Chapman, Benjamin P.; Duberstein, Paul R.
2011-01-01
Emerging research has examined individual differences in affective forecasting; however, we are aware of no published study to date linking psychopathology symptoms to affective forecasting problems. Pitting cognitive theory against depressive realism theory, we examined whether dysphoria was associated with negatively biased affective forecasts or greater accuracy. Participants (n = 325) supplied predicted and actual emotional reactions for three days surrounding an emotionally-evocative relational event, Valentine’s Day. Predictions were made a month prior to the holiday. Consistent with cognitive theory, we found evidence for a dysphoric forecasting bias – the tendency of individuals in dysphoric states to overpredict negative emotional reactions to future events. The dysphoric forecasting bias was robust across ratings of positive and negative affect, forecasts for pleasant and unpleasant scenarios, continuous and categorical operationalizations of dysphoria, and three time points of observation. Similar biases were not observed in analyses examining the independent effects of anxiety and hypomania. Findings provide empirical evidence for the long assumed influence of depressive symptoms on future expectations. The present investigation has implications for affective forecasting studies examining information processing constructs, decision making, and broader domains of psychopathology. PMID:22397734
Hoerger, Michael; Quirk, Stuart W; Chapman, Benjamin P; Duberstein, Paul R
2012-01-01
Emerging research has examined individual differences in affective forecasting; however, we are aware of no published study to date linking psychopathology symptoms to affective forecasting problems. Pitting cognitive theory against depressive realism theory, we examined whether dysphoria was associated with negatively biased affective forecasts or greater accuracy. Participants (n=325) supplied predicted and actual emotional reactions for three days surrounding an emotionally evocative relational event, Valentine's Day. Predictions were made a month prior to the holiday. Consistent with cognitive theory, we found evidence for a dysphoric forecasting bias-the tendency of individuals in dysphoric states to overpredict negative emotional reactions to future events. The dysphoric forecasting bias was robust across ratings of positive and negative affect, forecasts for pleasant and unpleasant scenarios, continuous and categorical operationalisations of dysphoria, and three time points of observation. Similar biases were not observed in analyses examining the independent effects of anxiety and hypomania. Findings provide empirical evidence for the long-assumed influence of depressive symptoms on future expectations. The present investigation has implications for affective forecasting studies examining information-processing constructs, decision making, and broader domains of psychopathology.
Apostolova, Liana G.; Hwang, Kristy S.; Kohannim, Omid; Avila, David; Elashoff, David; Jack, Clifford R.; Shaw, Leslie; Trojanowski, John Q.; Weiner, Michael W.; Thompson, Paul M.
2014-01-01
Biomarkers are the only feasible way to detect and monitor presymptomatic Alzheimer's disease (AD). No single biomarker can predict future cognitive decline with an acceptable level of accuracy. In addition to designing powerful multimodal diagnostic platforms, a careful investigation of the major sources of disease heterogeneity and their influence on biomarker changes is needed. Here we investigated the accuracy of a novel multimodal biomarker classifier for differentiating cognitively normal (NC), mild cognitive impairment (MCI) and AD subjects with and without stratification by ApoE4 genotype. 111 NC, 182 MCI and 95 AD ADNI participants provided both structural MRI and CSF data at baseline. We used an automated machine-learning classifier to test the ability of hippocampal volume and CSF Aβ, t-tau and p-tau levels, both separately and in combination, to differentiate NC, MCI and AD subjects, and predict conversion. We hypothesized that the combined hippocampal/CSF biomarker classifier model would achieve the highest accuracy in differentiating between the three diagnostic groups and that ApoE4 genotype will affect both diagnostic accuracy and biomarker selection. The combined hippocampal/CSF classifier performed better than hippocampus-only classifier in differentiating NC from MCI and NC from AD. It also outperformed the CSF-only classifier in differentiating NC vs. AD. Our amyloid marker played a role in discriminating NC from MCI or AD but not for MCI vs. AD. Neurodegenerative markers contributed to accurate discrimination of AD from NC and MCI but not NC from MCI. Classifiers predicting MCI conversion performed well only after ApoE4 stratification. Hippocampal volume and sex achieved AUC = 0.68 for predicting conversion in the ApoE4-positive MCI, while CSF p-tau, education and sex achieved AUC = 0.89 for predicting conversion in ApoE4-negative MCI. These observations support the proposed biomarker trajectory in AD, which postulates that amyloid markers become abnormal early in the disease course while markers of neurodegeneration become abnormal later in the disease course and suggests that ApoE4 could be at least partially responsible for some of the observed disease heterogeneity. PMID:24634832
Meng, Xing; Jiang, Rongtao; Lin, Dongdong; Bustillo, Juan; Jones, Thomas; Chen, Jiayu; Yu, Qingbao; Du, Yuhui; Zhang, Yu; Jiang, Tianzi; Sui, Jing; Calhoun, Vince D.
2016-01-01
Neuroimaging techniques have greatly enhanced the understanding of neurodiversity (human brain variation across individuals) in both health and disease. The ultimate goal of using brain imaging biomarkers is to perform individualized predictions. Here we proposed a generalized framework that can predict explicit values of the targeted measures by taking advantage of joint information from multiple modalities. This framework also enables whole brain voxel-wise searching by combining multivariate techniques such as ReliefF, clustering, correlation-based feature selection and multiple regression models, which is more flexible and can achieve better prediction performance than alternative atlas-based methods. For 50 healthy controls and 47 schizophrenia patients, three kinds of features derived from resting-state fMRI (fALFF), sMRI (gray matter) and DTI (fractional anisotropy) were extracted and fed into a regression model, achieving high prediction for both cognitive scores (MCCB composite r = 0.7033, MCCB social cognition r = 0.7084) and symptomatic scores (positive and negative syndrome scale [PANSS] positive r = 0.7785, PANSS negative r = 0.7804). Moreover, the brain areas likely responsible for cognitive deficits of schizophrenia, including middle temporal gyrus, dorsolateral prefrontal cortex, striatum, cuneus and cerebellum, were located with different weights, as well as regions predicting PANSS symptoms, including thalamus, striatum and inferior parietal lobule, pinpointing the potential neuromarkers. Finally, compared to a single modality, multimodal combination achieves higher prediction accuracy and enables individualized prediction on multiple clinical measures. There is more work to be done, but the current results highlight the potential utility of multimodal brain imaging biomarkers to eventually inform clinical decision-making. PMID:27177764
Jan, Saadia Nosheen; Khan, Farid Ahmed; Bashir, Muhammad Mustehsan; Nasir, Muneeb; Ansari, Hamid Hussain; Shami, Hussan Birkhez; Nazir, Umer; Hanif, Asif; Sohail, Muhammad
2018-03-01
To compare the accuracy of Laser Doppler Imaging (LDI) and clinical assessment in differentiating between superficial and deep partial thickness burns to decide whether early tangential excision and grafting or conservative management should be employed to optimize burn and patient management. March 2015 to November 2016. Ninety two wounds in 34 patients reporting within 5days of less than 40% burn surface area were included. Unstable patients, pregnant females and those who expired were excluded. The wounds were clinically assessed and LDI done concomitantly Plastic Surgeons blinded to each other's findings. Wound appearance, color, blanching, pain, hair follicle dislodgement were the clinical parameters that distinguished between superficial and deep partial thickness burns. On day 21, the wounds were again assessed for the presence of healing by the same plastic surgeons. The findings were correlated with the initial findings on LDI and clinical assessment and the results statistically analyzed. The data of 92 burn wounds was analyzed using SPSS (ver. 17). Clinical assessment correctly identified the depth of 75 and LDI 83 wounds, giving diagnostic accuracies of 81.52% and 90.21% respectively. The sensitivity of clinical assessment was 81% and of LDI 92.75%, whereas the specificity was 82% for both. The positive predictive value was 93% for clinical assessment and 94% for LDI while the negative predictive value was 59% and 79% respectively. Predictive accuracy of LDI was found to be better than clinical assessment in the prediction of wound healing, the gold standard for wound healing being 21 days. As such it can prove to be a reliable and viable cost effective alternative per se to clinical assessment. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.
Hassan, Eman M; Omran, Dalia A; El Beshlawey, Mohamad L; Abdo, Mahmoud; El Askary, Ahmad
2014-02-01
Gastroesophageal varices are present in approximately 50% of patients with liver cirrhosis. The aim of this study was to evaluate liver stiffness measurement (LSM), Fib-4, Forns Index and Lok Score as noninvasive predictors of esophageal varices (EV). This prospective study included 65 patients with HCV-related liver cirrhosis. All patients underwent routine laboratory tests, transient elastograhy (TE) and esophagogastroduodenoscopy. FIB-4, Forns Index and Lok Score were calculated. The diagnostic performances of these methods were assessed using sensitivity, specificity, positive predictive value, negative predictive value, accuracy and receiver operating characteristic curves. All predictors (LSM, FIB-4, Forns Index and Lok Score) demonstrated statistically significant correlation with the presence and the grade of EV. TE could diagnose EV at a cutoff value of 18.2kPa. Fib-4, Forns Index, and Lok Score could diagnose EV at cutoff values of 2.8, 6.61 and 0.63, respectively. For prediction of large varices (grade 2, 3), LSM showed the highest accuracy (80%) with a cutoff of 22.4kPa and AUROC of 0.801. Its sensitivity was 84%, specificity 72%, PPV 84% and NPV 72%. The diagnostic accuracies of FIB-4, Forns Index and Lok Score were 70%, 70% and76%, respectively, at cutoffs of 3.3, 6.9 and 0.7, respectively. For diagnosis of large esophageal varices, adding TE to each of the other diagnostic indices (serum fibrosis scores) increased their sensitivities with little decrease in their specificities. Moreover, this combination decreased the LR- in all tests. Noninvasive predictors can restrict endoscopic screening. This is very important as non invasiveness is now a major goal in hepatology. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.
Fujita, Yoshihito; Yoshizawa, Saya; Hoshika, Maiko; Inoue, Koichi; Matsushita, Shoko; Oka, Hisao; Sobue, Kazuya
2017-01-01
The accuracy of simulation-predicted fentanyl concentration in different types of surgical procedure is not fully understood. We wished to estimate the effect of different types of surgical procedure on the accuracy of such simulations. Fifty patients who had undergone elective mastectomy or laparoscopic prostatectomy (American Society of Anesthesiologists physical status = I-II) were enrolled. Anesthesia was maintained throughout surgery with sevoflurane and a bolus infusion of fentanyl. A maintenance infusion was administered with 8 mL/kg/h Ringer's acetate solution from the start of anesthesia to completion of blood sampling. An infusion to compensate for blood loss was administered (one to two volumes of hydroxyethyl starch). A blood sample was drawn every 30 min during anesthesia.We measured the plasma concentration of fentanyl in 358 samples from 50 patients. The plasma concentration of fentanyl was correlated significantly with the simulated predicted fentanyl concentration ( r = 0.734, P < 0.01) but 36.0% of all samples had a difference greater than ±0.5 ng/mL. Approximately 0.3 ng/mL of a fixed bias was shown throughout mastectomy. During laparoscopic prostatectomy, the fixed bias gradually became negative from ≈0.3 to -0.3 ng/mL as the sampling stage proceeded. The predicted concentration of fentanyl was significantly correlated with the plasma concentration of fentanyl ( r = 0.734). However, there were different patterns of a fixed bias between mastectomy and laparoscopic prostatectomy groups. We should pay attention to this tendency among different surgical procedures. UMIN000005110.
Malacarne, D; Pesenti, R; Paolucci, M; Parodi, S
1993-01-01
For a database of 826 chemicals tested for carcinogenicity, we fragmented the structural formula of the chemicals into all possible contiguous-atom fragments with size between two and eight (nonhydrogen) atoms. The fragmentation was obtained using a new software program based on graph theory. We used 80% of the chemicals as a training set and 20% as a test set. The two sets were obtained by random sorting. From the training sets, an average (8 computer runs with independently sorted chemicals) of 315 different fragments were significantly (p < 0.125) associated with carcinogenicity or lack thereof. Even using this relatively low level of statistical significance, 23% of the molecules of the test sets lacked significant fragments. For 77% of the molecules of the test sets, we used the presence of significant fragments to predict carcinogenicity. The average level of accuracy of the predictions in the test sets was 67.5%. Chemicals containing only positive fragments were predicted with an accuracy of 78.7%. The level of accuracy was around 60% for chemicals characterized by contradictory fragments or only negative fragments. In a parallel manner, we performed eight paired runs in which carcinogenicity was attributed randomly to the molecules of the training sets. The fragments generated by these pseudo-training sets were devoid of any predictivity in the corresponding test sets. Using an independent software program, we confirmed (for the complex biological endpoint of carcinogenicity) the validity of a structure-activity relationship approach of the type proposed by Klopman and Rosenkranz with their CASE program. Images Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. PMID:8275991
Rezk, Mohamed; Gaber, Wael; Shaheen, Abdelhamid; Nofal, Ahmed; Emara, Mahmoud; Gamal, Awni; Badr, Hassan
2018-06-12
To determine if second trimester mean platelet volume (MPV) and serum uric acid are reasonable predictors of preeclampsia (PE) or not, in patients at moderate and low risk. This prospective study was conducted on 9522 women at low or moderate risk for developing PE who underwent dual measurements of MPV and serum uric acid at late first trimester (10-12 weeks) and at second trimester (18-20 weeks) and subsequently divided into two groups; PE group (n = 286) who later developed PE and non-PE group (n = 9236). Test validity of MPV and serum uric acid was the primary outcome measure. Data were collected and analyzed. Second trimester MPV is a good predictor for development of PE at a cutoff value of 9.55 fL with area under the curve (AUC) of 0.86, sensitivity of 95.2%, specificity of 66.7%, positive predictive value (PPV) of 87%, negative predictive value (NPV) of 85.7%, and accuracy of 86.7%. Second trimester serum uric acid is a good predictor for development of PE at a cutoff value of 7.35 mg/dL, with AUC of 0.85, sensitivity of 95.2%, specificity of 55.6%, PPV of 83.3%, NPV of 83.3%, and accuracy of 83.3%. Combination of both tests has a sensitivity of 100%, specificity of 22.2%, PPV of 75%, NPV of 100%, and accuracy of 76.7%. Second trimester MPV and serum uric acid alone or in combination could be used as a useful biochemical markers for prediction of PE based on their validity, simplicity, and availability.
Yenilmez, Ercan; Çetinkaya, Rıza Aytaç; Tural, Ersin
2018-05-04
The most important difficulties about management of hepatitis B are still determining the liver damage and the right time to start antiviral therapy. To reveal the role of hepatitis B virus DNA threshold level for prediction of liver fibrosis and inflammation in young-aged hepatitis B e antigen negative chronic hepatitis B patients. Diagnostic accuracy study. A total of 273 hepatitis B e antigen negative young chronic hepatitis B patients with any hepatitis B virus DNA levels between 2008 and 2016, who had liver biopsy after at least 6 months follow up period, enrolled in this retrospective study. We created two groups as case and control, cases with hepatitis B virus DNA levels below 2.000 IU/mL and controls with hepatitis B virus DNA levels over 2.000 IU/mL. Having histological activity index ≥4 or/and fibrosis scores ≥2 were defined as significant histological abnormality. Then, we analyzed the relationship between these groups. We showed that significant fibrosis may occur in one third of young chronic hepatitis B patients with low viremia (30.2%, n=42/139 in cases, %55.2, n=74/134 in controls). Among the 42 cases with low viremia and significant fibrosis, 21.4% had alanine aminotransferase level between 40-59 U/L, 42.8% had alanine aminotransferase level between 60-79 U/L, and 35.7% had alanine aminotransferase level over 80 U/L. There was weak correlation between hepatitis B virus DNA threshold level and fibrosis score (p=0.000, rho=0.253). The optimum serum hepatitis B virus DNA threshold level in our study for predicting significant fibrosis was 1293 IU/mL (p=0.00, AUC: 0.657±0.034). The optimum alanine aminotransferase threshold level for predicting significant histological activity index and fibrosis was 64.5 and 59.5 U/L, respectively. The sensitivity and the specificity of 1293 vs 2000 IU/mL hepatitis B virus DNA threshold with 60 U/L alanine aminotransferase threshold level for predicting F≥2 fibrosis score were similar (sensitivity: 0.43 and 0.38, respectively; specificity: 0.76 and 0.77, respectively). Significant fibrosis may occur even in young cases with low viremia. It is not possible to define a single threshold hepatitis B virus DNA level for differentiating inactive carriers from patients with hepatitis B e antigen-negative chronic hepatitis. Diagnostic accuracy of hepatitis B virus DNA with alanine aminotransferase thresholds for the prediction of significant fibrosis is weak.
Gholkar, Nikhil Shirish; Saha, Subhas Chandra; Prasad, GRV; Bhattacharya, Anish; Srinivasan, Radhika; Suri, Vanita
2014-01-01
Lymph nodal (LN) metastasis is the most important prognostic factor in high-risk endometrial cancer. However, the benefit of routine lymphadenectomy in endometrial cancer is controversial. This study was conducted to assess the accuracy of [18F] fluorodeoxyglucose-positron emission tomography/computed tomography ([18F] FDG-PET/CT) in detection of pelvic and para-aortic nodal metastases in high-risk endometrial cancer. 20 patients with high-risk endometrial carcinoma underwent [18F] FDG-PET/CT followed by total abdominal hysterectomy, bilateral salpingo-oophorectomy and systematic pelvic lymphadenectomy with or without para-aortic lymphadenectomy. The findings on histopathology were compared with [18F] FDG-PET/CT findings to calculate the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of [18F] FDG-PET/CT. The pelvic nodal findings were analyzed on a patient and nodal chain based criteria. The para-aortic nodal findings were reported separately. Histopathology documented nodal involvement in two patients (10%). For detection of pelvic nodes, on a patient based analysis, [18F] FDG-PET/CT had a sensitivity of 100%, specificity of 61.11%, PPV of 22.22%, NPV of 100% and accuracy of 65% and on a nodal chain based analysis, [18F] FDG-PET/CT had a sensitivity of 100%, specificity of 80%, PPV of 20%, NPV of 100%, and accuracy of 80.95%. For detection of para-aortic nodes, [18F] FDG-PET/CT had sensitivity of 100%, specificity of 66.67%, PPV of 20%, NPV of 100%, and accuracy of 69.23%. Although [18F] FDG-PET/CT has high sensitivity for detection of LN metastasis in endometrial carcinoma, it had moderate accuracy and high false positivity. However, the high NPV is important in selecting patients in whom lymphadenectomy may be omitted. PMID:25538488
Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.
1996-01-01
We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.