Sample records for neutral-point-clamped indirect matrix

  1. Fault-tolerant three-level inverter

    DOEpatents

    Edwards, John; Xu, Longya; Bhargava, Brij B.

    2006-12-05

    A method for driving a neutral point clamped three-level inverter is provided. In one exemplary embodiment, DC current is received at a neutral point-clamped three-level inverter. The inverter has a plurality of nodes including first, second and third output nodes. The inverter also has a plurality of switches. Faults are checked for in the inverter and predetermined switches are automatically activated responsive to a detected fault such that three-phase electrical power is provided at the output nodes.

  2. A new type of single-phase five-level inverter

    NASA Astrophysics Data System (ADS)

    Xu, Zhi; Li, Shengnan; Qin, Risheng; Zhao, Yanhang

    2017-11-01

    At present, Neutral Point Clamped (NPC) multilevel inverter is widely applied in new energy field. However, it has some disadvantages including low utilization rate of direct current (DC) voltage source and the unbalance of neutral potential. Therefore, a new single-phase five level inverter is proposed in this paper. It has two stage structure, the former stage is equivalent to three level DC/DC converter, and the back stage uses H bridge to realize inverter. Compared with the original central clamp type inverter, the new five level inverter can improve the utilization of DC voltage, and realize the neutral point potential balance with hysteresis comparator.

  3. Novel switching method for single-phase NPC three-level inverter with neutral-point voltage control

    NASA Astrophysics Data System (ADS)

    Lee, June-Seok; Lee, Seung-Joo; Lee, Kyo-Beum

    2018-02-01

    This paper proposes a novel switching method with the neutral-point voltage control in a single-phase neutral-point-clamped three-level inverter (SP-NPCI) used in photovoltaic systems. A proposed novel switching method for the SP-NPCI improves the efficiency. The main concept is to fix the switching state of one leg. As a result, the switching loss decreases and the total efficiency is improved. In addition, it enables the maximum power-point-tracking operation to be performed by applying the proposed neutral-point voltage control algorithm. This control is implemented by modifying the reference signal. Simulation and experimental results provide verification of the performance of a novel switching method with the neutral-point voltage control.

  4. Control method for peak power delivery with limited DC-bus voltage

    DOEpatents

    Edwards, John; Xu, Longya; Bhargava, Brij B.

    2006-09-05

    A method for driving a neutral point-clamped multi-level voltage source inverter supplying a synchronous motor is provided. A DC current is received at a neutral point-clamped multi-level voltage source inverter. The inverter has first, second, and third output nodes. The inverter also has a plurality of switches. A desired speed of a synchronous motor connected to the inverter by the first second and third nodes is received by the inverter. The synchronous motor has a rotor and the speed of the motor is defined by the rotational rate of the rotor. A position of the rotor is sensed, current flowing to the motor out of at least two of the first, second, and third output nodes is sensed, and predetermined switches are automatically activated by the inverter responsive to the sensed rotor position, the sensed current, and the desired speed.

  5. Design and Comparison of Cascaded H-Bridge, Modular Multilevel Converter, and 5-L Active Neutral Point Clamped Topologies for Motor Drive Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marzoughi, Alinaghi; Burgos, Rolando; Boroyevich, Dushan

    This paper presents the design procedure and comparison of converters currently used in medium-voltage high-power motor drive applications. For this purpose, the cascaded H-bridge (CHB), modular multilevel converter (MMC), and five-level active neutral point clamped (5-L ANPC) topologies are targeted. The design is performed using 1.7-kV insulated gate bipolar transistors (IGBTs) for CHB and MMC converters, and utilizing 3.3- and 4.5-kV IGBTs for 5-L ANPC topology as normally done in industry. The comparison is done between the designed converter topologies at three different voltage levels (4.16, 6.9, and 13.8 kV, with only the first two voltage levels in case ofmore » the 5-L ANPC) and two different power levels (3 and 5 MVA), in order to elucidate the dependence of different parameters on voltage and power rating. Finally, the comparison is done from several points of view such as efficiency, capacitive energy storage, semiconductor utilization, parts count (for measure of reliability), and power density.« less

  6. Multiple scattered radiation emerging from Rayleigh and continental haze layers. I - Radiance, polarization, and neutral points

    NASA Technical Reports Server (NTRS)

    Kattawar, G. W.; Plass, G. N.; Hitzfelder, S. J.

    1976-01-01

    The matrix operator method was used to calculate the polarization of radiation scattered on layers of various optical thicknesses, with results compared for Rayleigh scattering and for scattering from a continental haze. In both cases, there are neutral points arising from the zeros of the polarization of single scattered photons at scattering angles of zero and 180 degrees. The angular position of these Rayleigh-like neutral points (RNP) in the sky shows appreciable variation with the optical thickness of the scattering layer for a Rayleigh phase matrix, but only a small variation for haze L phase matrix. Another type of neutral point exists for non-Rayleigh phase functions that is associated with the zeros of the polarization for single scattering which occurs between the end points of the curve. A comparison of radiances calculated from the complete theory of radiative transfer using Stokes vectors with those obtained from the scalar theory shows that differences of the order of 23% may be obtained for Rayleigh scattering, while the largest difference found for a haze L phase function was of the order of 0.1%.

  7. The design, fabrication and delivery of a spacelab neutral buoyancy Instrument Pointing System (IPS) mockup. [underwater training simulator

    NASA Technical Reports Server (NTRS)

    Vanvalkenburgh, C. N.

    1984-01-01

    Underwater simulations of EVA contingency operations such as manual jettison, payload disconnect, and payload clamp actuation were used to define crew aid needs and mockup pecularities and characteristics to verify the validity of simulation using the trainer. A set of mockup instrument pointing system tests was conducted and minor modifications and refinements were made. Flight configuration struts were tested and verified to be operable by the flight crew. Tasks involved in developing the following end items are described: IPS gimbal system, payload, and payload clamp assembly; the igloos (volumetric); spacelab pallets, experiments, and hardware; experiment, and hardware; experiment 7; and EVA hand tools, support hardware (handrails and foot restraints). The test plan preparation and test support are also covered.

  8. Adaptive composites with embedded NiTiCu wires

    NASA Astrophysics Data System (ADS)

    Balta-Neumann, J. Antonio; Michaud, Veronique J.; Parlinska, Magdelena; Gotthardt, Rolf; Manson, Jan-Anders E.

    2001-07-01

    Adaptive composites have been produced by embedding prestrained shape memory alloy (SMA) wires into an epoxy matrix, reinforced with aramid fibers. These materials demonstrate attractive effects such as shape change or a shift in the vibration frequency upon activation. When heated above their transformation temperature, the wires' strain recovery is confined, and recovery stresses are generated. As a result, if the wires are placed along the neutral axis of a composite beam, a shift in resonance vibration frequency can be observed. To optimize the design of such composites, the matrix - SMA wire interfacial shear strength has been analyzed with the pull out testing technique. It is shown that the nature of the wire surface influences the interfacial shear strength, and that satisfactory results are obtained for SMA wires with a thin oxide layer. Composite samples consisting of two different types of pre- strained NiTiCu wires embedded in either pure epoxy matrix or Kevlar-epoxy matrix were produced. The recovery force and vibration response of composites were measured in a clamped-clamped configuration, to assess the effect of wire type and volume fraction. The results are highly reproducible in all cases with a narrow hysteresis loop, which makes NiTiCu wires good candidates for adaptive composites. The recovery forces increase with the volume fraction of the embedded wires, are higher when the wires are embedded in a low CTE matrix and, at a given temperature, are higher when the wire transformation temperature is lower.

  9. A new balancing three level three dimensional space vector modulation strategy for three level neutral point clamped four leg inverter based shunt active power filter controlling by nonlinear back stepping controllers.

    PubMed

    Chebabhi, Ali; Fellah, Mohammed Karim; Kessal, Abdelhalim; Benkhoris, Mohamed F

    2016-07-01

    In this paper is proposed a new balancing three-level three dimensional space vector modulation (B3L-3DSVM) strategy which uses a redundant voltage vectors to realize precise control and high-performance for a three phase three-level four-leg neutral point clamped (NPC) inverter based Shunt Active Power Filter (SAPF) for eliminate the source currents harmonics, reduce the magnitude of neutral wire current (eliminate the zero-sequence current produced by single-phase nonlinear loads), and to compensate the reactive power in the three-phase four-wire electrical networks. This strategy is proposed in order to gate switching pulses generation, dc bus voltage capacitors balancing (conserve equal voltage of the two dc bus capacitors), and to switching frequency reduced and fixed of inverter switches in same times. A Nonlinear Back Stepping Controllers (NBSC) are used for regulated the dc bus voltage capacitors and the SAPF injected currents to robustness, stabilizing the system and to improve the response and to eliminate the overshoot and undershoot of traditional PI (Proportional-Integral). Conventional three-level three dimensional space vector modulation (C3L-3DSVM) and B3L-3DSVM are calculated and compared in terms of error between the two dc bus voltage capacitors, SAPF output voltages and THDv, THDi of source currents, magnitude of source neutral wire current, and the reactive power compensation under unbalanced single phase nonlinear loads. The success, robustness, and the effectiveness of the proposed control strategies are demonstrated through simulation using Sim Power Systems and S-Function of MATLAB/SIMULINK. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Control of a Vanadium Redox Battery and supercapacitor using a Three-Level Neutral Point Clamped converter

    NASA Astrophysics Data System (ADS)

    Etxeberria, A.; Vechiu, I.; Baudoin, S.; Camblong, H.; Kreckelbergh, S.

    2014-02-01

    The increasing use of distributed generators, which are mainly based on renewable sources, can create several issues in the operation of the electric grid. The microgrid is being analysed as a solution to the integration in the grid of the renewable sources at a high penetration level in a controlled way. The storage systems play a vital role in order to keep the energy and power balance of the microgrid. Due to the technical limitations of the currently available storage systems, it is necessary to use more than one storage technology to satisfy the requirements of the microgrid application. This work validates in simulations and experimentally the use of a Three-Level Neutral Point Clamped converter to control the power flow of a hybrid storage system formed by a SuperCapacitor and a Vanadium Redox Battery. The operation of the system is validated in two case studies in the experimental platform installed in ESTIA. The experimental results prove the validity of the proposed system as well as the designed control algorithm. The good agreement among experimental and simulation results also validates the simulation model, that can therefore be used to analyse the operation of the system in different case studies.

  11. Combined acute hyperglycemic and hyperinsulinemic clamp induced profibrotic and proinflammatory responses in the kidney

    PubMed Central

    DeSilva, Kristin; Sorice, Gian Pio; Muscogiuri, Giovanna; Jimenez, Fabio; Ahuja, Seema; Barnes, Jefferey L.; Choudhury, Goutam Ghosh; Musi, Nicolas; DeFronzo, Ralph; Kasinath, Balakuntalam S.

    2013-01-01

    Increase in matrix protein content in the kidney is a cardinal feature of diabetic kidney disease. While renal matrix protein content is increased by chronic hyperglycemia, whether it is regulated by acute elevation of glucose and insulin has not been addressed. In this study, we aimed to evaluate whether short duration of combined hyperglycemia and hyperinsulinemia, mimicking the metabolic environment of prediabetes and early type 2 diabetes, induces kidney injury. Normal rats were subjected to either saline infusion (control, n = 4) or 7 h of combined hyperglycemic-hyperinsulinemic clamp (HG+HI clamp; n = 6). During the clamp, plasma glucose and plasma insulin were maintained at about 350 mg/dl and 16 ng/ml, respectively. HG+HI clamp increased the expression of renal cortical transforming growth factor-β (TGF-β) and renal matrix proteins, laminin and fibronectin. This was associated with the activation of SMAD3, Akt, mammalian target of rapamycin (mTOR) complexes, and ERK signaling pathways and their downstream target events in the initiation and elongation phases of mRNA translation, an important step in protein synthesis. Additionally, HG+HI clamp provoked renal inflammation as shown by the activation of Toll-like receptor 4 (TLR4) and infiltration of CD68-positive monocytes. Urinary F2t isoprostane excretion, an index of renal oxidant stress, was increased in the HG+HI clamp rats. We conclude that even a short duration of hyperglycemia and hyperinsulinemia contributes to activation of pathways that regulate matrix protein synthesis, inflammation, and oxidative stress in the kidney. This finding could have implications for the control of short-term rises in blood glucose in diabetic individuals at risk of developing kidney disease. PMID:24108867

  12. Combined acute hyperglycemic and hyperinsulinemic clamp induced profibrotic and proinflammatory responses in the kidney.

    PubMed

    Mariappan, Meenalakshmi M; DeSilva, Kristin; Sorice, Gian Pio; Muscogiuri, Giovanna; Jimenez, Fabio; Ahuja, Seema; Barnes, Jefferey L; Choudhury, Goutam Ghosh; Musi, Nicolas; DeFronzo, Ralph; Kasinath, Balakuntalam S

    2014-02-01

    Increase in matrix protein content in the kidney is a cardinal feature of diabetic kidney disease. While renal matrix protein content is increased by chronic hyperglycemia, whether it is regulated by acute elevation of glucose and insulin has not been addressed. In this study, we aimed to evaluate whether short duration of combined hyperglycemia and hyperinsulinemia, mimicking the metabolic environment of prediabetes and early type 2 diabetes, induces kidney injury. Normal rats were subjected to either saline infusion (control, n = 4) or 7 h of combined hyperglycemic-hyperinsulinemic clamp (HG+HI clamp; n = 6). During the clamp, plasma glucose and plasma insulin were maintained at about 350 mg/dl and 16 ng/ml, respectively. HG+HI clamp increased the expression of renal cortical transforming growth factor-β (TGF-β) and renal matrix proteins, laminin and fibronectin. This was associated with the activation of SMAD3, Akt, mammalian target of rapamycin (mTOR) complexes, and ERK signaling pathways and their downstream target events in the initiation and elongation phases of mRNA translation, an important step in protein synthesis. Additionally, HG+HI clamp provoked renal inflammation as shown by the activation of Toll-like receptor 4 (TLR4) and infiltration of CD68-positive monocytes. Urinary F2t isoprostane excretion, an index of renal oxidant stress, was increased in the HG+HI clamp rats. We conclude that even a short duration of hyperglycemia and hyperinsulinemia contributes to activation of pathways that regulate matrix protein synthesis, inflammation, and oxidative stress in the kidney. This finding could have implications for the control of short-term rises in blood glucose in diabetic individuals at risk of developing kidney disease.

  13. Effect of molecular anisotropy on the intensity and degree of polarization of light scattered from model atmospheres

    NASA Technical Reports Server (NTRS)

    Bahethi, O. P.; Fraser, R. S.

    1975-01-01

    Computations of the intensity, flux, degree of polarization, and the positions of neutral points are presented for models of the terrestrial gaseous and hazy atmospheres by incorporating the molecular anisotropy due to air in the Rayleigh scattering optical thickness and phase matrix. Molecular anisotropy causes significant changes in the intensity, flux and the degree of polarization of the scattered light. The positions of neutral points do not change significantly. When the Rayleigh scattering optical thickness is kept constant and the molecular anisotropy factor is included only in the Rayleigh phase matrix, the flux does not change and the intensity and positions of neutron points change by a small amount. The changes in the degree of polarization are still significant.

  14. Automatic Assembly of Combined Checkingfixture for Auto-Body Components Based Onfixture Elements Libraries

    NASA Astrophysics Data System (ADS)

    Jiang, Jingtao; Sui, Rendong; Shi, Yan; Li, Furong; Hu, Caiqi

    In this paper 3-D models of combined fixture elements are designed, classified by their functions, and saved in computer as supporting elements library, jointing elements library, basic elements library, localization elements library, clamping elements library, and adjusting elements library etc. Then automatic assembly of 3-D combined checking fixture for auto-body part is presented based on modularization theory. And in virtual auto-body assembly space, Locating constraint mapping technique and assembly rule-based reasoning technique are used to calculate the position of modular elements according to localization points and clamp points of auto-body part. Auto-body part model is transformed from itself coordinate system space to virtual assembly space by homogeneous transformation matrix. Automatic assembly of different functional fixture elements and auto-body part is implemented with API function based on the second development of UG. It is proven in practice that the method in this paper is feasible and high efficiency.

  15. A Nerve Clamp Electrode Design for Indirect Stimulation of Skeletal Muscle

    DTIC Science & Technology

    2010-10-01

    neurons. This device enables stimulation of muscle contraction indirectly as opposed to contraction from direct muscle stimulation. The electrode is able...to stimulate indirect muscle contraction when tested on ex vivo preparations from rodent phrenic nerve-hemidiaphragm muscle in similar fashion to...unsuccessful in stimulating indirect muscle contraction . Therefore, this novel electrode is useful for physiological assessment of nerve agents and

  16. $$B^0_{(s)}$$-mixing matrix elements from lattice QCD for the Standard Model and beyond

    DOE PAGES

    Bazavov, A.; Bernard, C.; Bouchard, C. M.; ...

    2016-06-28

    We calculate—for the first time in three-flavor lattice QCD—the hadronic matrix elements of all five local operators that contribute to neutral B 0- and B s-meson mixing in and beyond the Standard Model. We present a complete error budget for each matrix element and also provide the full set of correlations among the matrix elements. We also present the corresponding bag parameters and their correlations, as well as specific combinations of the mixing matrix elements that enter the expression for the neutral B-meson width difference. We obtain the most precise determination to date of the SU(3)-breaking ratio ξ=1.206(18)(6), where themore » second error stems from the omission of charm-sea quarks, while the first encompasses all other uncertainties. The threefold reduction in total uncertainty, relative to the 2013 Flavor Lattice Averaging Group results, tightens the constraint from B mixing on the Cabibbo-Kobayashi-Maskawa (CKM) unitarity triangle. Our calculation employs gauge-field ensembles generated by the MILC Collaboration with four lattice spacings and pion masses close to the physical value. We use the asqtad-improved staggered action for the light-valence quarks and the Fermilab method for the bottom quark. We use heavy-light meson chiral perturbation theory modified to include lattice-spacing effects to extrapolate the five matrix elements to the physical point. We combine our results with experimental measurements of the neutral B-meson oscillation frequencies to determine the CKM matrix elements |V td| = 8.00(34)(8)×10 -3, |V ts| = 39.0(1.2)(0.4)×10 -3, and |V td/V ts| = 0.2052(31)(10), which differ from CKM-unitarity expectations by about 2σ. In addition, these results and others from flavor-changing-neutral currents point towards an emerging tension between weak processes that are mediated at the loop and tree levels.« less

  17. Combination Space Station Handrail Clamp and Pointing Device

    NASA Technical Reports Server (NTRS)

    Hughes, Stephen J. (Inventor)

    1999-01-01

    A device for attaching an experiment carrier to a space station handrail is provided. The device has two major components, a clamping mechanism for attachment to a space station handrail, and a pointing carrier on which an experiment package can be mounted and oriented. The handrail clamp uses an overcenter mechanism and the carrier mechanism uses an adjustable preload ball and socket for carrier positioning. The handrail clamp uses a stack of disk springs to provide a spring loaded button. This configuration provides consistent clamping force over a range of possible handrail thicknesses. Three load points are incorporated in the clamping mechanism thereby spreading the clamping load onto three separate points on the handrail. A four bar linkage is used to provide for a single actuation lever for all three load points. For additional safety, a secondary lock consisting of a capture plate and push lock keeps the clamp attached to the handrail in the event of main clamp failure. For the carrier positioning mechanism, a ball in a spring loaded socket uses friction to provide locking torque; however. the ball and socket are torque limited so that the ball ran slip under kick loads (125 pounds or greater). A lead screw attached to disk spring stacks is used to provide an adjustable spring force on the socket. A locking knob is attached to the lead screw to allow for hand manipulation of the lead screw.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bazavov, A.; Bernard, C.; Bouchard, C. M.

    We calculate—for the first time in three-flavor lattice QCD—the hadronic matrix elements of all five local operators that contribute to neutral B 0- and B s-meson mixing in and beyond the Standard Model. We present a complete error budget for each matrix element and also provide the full set of correlations among the matrix elements. We also present the corresponding bag parameters and their correlations, as well as specific combinations of the mixing matrix elements that enter the expression for the neutral B-meson width difference. We obtain the most precise determination to date of the SU(3)-breaking ratio ξ=1.206(18)(6), where themore » second error stems from the omission of charm-sea quarks, while the first encompasses all other uncertainties. The threefold reduction in total uncertainty, relative to the 2013 Flavor Lattice Averaging Group results, tightens the constraint from B mixing on the Cabibbo-Kobayashi-Maskawa (CKM) unitarity triangle. Our calculation employs gauge-field ensembles generated by the MILC Collaboration with four lattice spacings and pion masses close to the physical value. We use the asqtad-improved staggered action for the light-valence quarks and the Fermilab method for the bottom quark. We use heavy-light meson chiral perturbation theory modified to include lattice-spacing effects to extrapolate the five matrix elements to the physical point. We combine our results with experimental measurements of the neutral B-meson oscillation frequencies to determine the CKM matrix elements |V td| = 8.00(34)(8)×10 -3, |V ts| = 39.0(1.2)(0.4)×10 -3, and |V td/V ts| = 0.2052(31)(10), which differ from CKM-unitarity expectations by about 2σ. In addition, these results and others from flavor-changing-neutral currents point towards an emerging tension between weak processes that are mediated at the loop and tree levels.« less

  19. Laser-assisted patch clamping: a methodology

    NASA Technical Reports Server (NTRS)

    Henriksen, G. H.; Assmann, S. M.; Evans, M. L. (Principal Investigator)

    1997-01-01

    Laser microsurgery can be used to perform both cell biological manipulations, such as targeted cell ablation, and molecular genetic manipulations, such as genetic transformation and chromosome dissection. In this report, we describe a laser microsurgical method that can be used either to ablate single cells or to ablate a small area (1-3 microns diameter) of the extracellular matrix. In plants and microorganisms, the extracellular matrix consists of the cell wall. While conventional patch clamping of these cells, as well as of many animal cells, requires enzymatic digestion of the extracellular matrix, we illustrate that laser microsurgery of a portion of the wall enables patch clamp access to the plasma membrane of higher plant cells remaining situated in their tissue environment. What follows is a detailed description of the construction and use of an economical laser microsurgery system, including procedures for single cell and targeted cell wall ablation. This methodology will be of interest to scientists wishing to perform cellular or subcellular ablation with a high degree of accuracy, or wishing to study how the extracellular matrix affects ion channel function.

  20. Matrix Determination of Reflectance of Hidden Object via Indirect Photography

    DTIC Science & Technology

    2012-03-01

    the hidden object. This thesis provides an alternative method of processing the camera images by modeling the system as a set of transport and...Distribution Function ( BRDF ). Figure 1. Indirect photography with camera field of view dictated by point of illumination. 3 1.3 Research Focus In an...would need to be modeled using radiometric principles. A large amount of the improvement in this process was due to the use of a blind

  1. Multiple scattered radiation emerging from Rayleigh and continental haze layers. 1: Radiance, polarization, and neutral points.

    PubMed

    Kattawar, G W; Plass, G N; Hitzfelder, S J

    1976-03-01

    The complete radiation field including polarization is calculated by the matrix operator method for scattering layers of various optical thicknesses. Results obtained for Rayleigh scattering are compared with those for scattering from a continental haze. Radiances calculated using Stokes vectors show differences as large as 23% compared to the approximate scalar theory of radiative transfer, while the same differences are only of the order of 0.1% for a continental haze phase function. The polarization of the reflected and transmitted radiation is given for a wide range of optical thicknesses of the scattering layer, for various solar zenith angles, and various surface albedos. Two entirely different types of neutral points occur for aerosol phase functions. Rayleigh-like neutral points (RNP) arise from the zero polarization in single scattering that occurs for all phase functions at scattering angles of 0 degrees and 180 degrees . For Rayleigh phase functions, the position of the RNP varies appreciably with the optical thickness of the scattering layer. At low solar elevations there may be four RNP. For a continental haze phase function the position of the RNP in the reflected radiation shows only a small variation with the optical thickness, and the RNP exists in the transmitted radiation only for extremely small optical thicknesses. Another type of neutral point (NRNP) exists for aerosol phase functions. It is associated with the zeros of the single scattered polarization, which occur between the end points of the curve; these are called non-Rayleigh neutral points (NRNP). There may be from zero to four of these neutral points associated with each zero of the single scattering curve. They occur over a range of azimuthal angles, unlike the RNP that are in the principal plane only. The position of these neutral points is given as a function of solar angle and optical thickness.

  2. An equivalent network representation of a clamped bimorph piezoelectric micromachined ultrasonic transducer with circular and annular electrodes using matrix manipulation techniques.

    PubMed

    Sammoura, Firas; Smyth, Katherine; Kim, Sang-Gook

    2013-09-01

    An electric circuit model for a clamped circular bimorph piezoelectric micromachined ultrasonic transducer (pMUT) was developed for the first time. The pMUT consisted of two piezoelectric layers sandwiched between three thin electrodes. The top and bottom electrodes were separated into central and annular electrodes by a small gap. While the middle electrode was grounded, the central and annular electrodes were biased with two independent voltage sources. The strain mismatch between the piezoelectric layers caused the plate to vibrate and transmit a pressure wave, whereas the received echo generated electric charges resulting from plate deformation. The clamped pMUT plate was separated into a circular and an annular plate, and the respective electromechanical transformation matrices were derived. The force and velocity vectors were properly selected using Hamilton's principle and the necessary boundary conditions were invoked. The electromechanical transformation matrix for the clamped circular pMUT was deduced using simple matrix manipulation techniques. The pMUT performance under three biasing schemes was elaborated: 1) central electrode only, 2) central and annular electrodes with voltages of the same magnitude and polarity, and 3) central and annular electrodes with voltages of the same magnitude and opposite polarity. The circuit parameters of the pMUT were extracted for each biasing scheme, including the transformer ratio, the clamped electric impedance, and the open-circuit mechanical impedance. Each pMUT scheme was characterized under different acoustic loadings using the theoretically developed model, which was verified with finite element modeling (FEM) simulation. The electrode size was optimized to maximize the electromechanical transformer ratio. As such, the developed model could provide more insight into the design, optimization, and characterization of pMUTs and allow for performance comparison with their cMUT counterparts.

  3. Model Predictive Control of LCL Three-level Photovoltaic Grid-connected Inverter

    NASA Astrophysics Data System (ADS)

    Liang, Cheng; Tian, Engang; Pang, Baobing; Li, Juan; Yang, Yang

    2018-05-01

    In this paper, neutral point clamped three-level inverter circuit is analyzed to establish a mathematical model of the three-level inverter in the αβ coordinate system. The causes and harms of the midpoint potential imbalance problem are described. The paper use the method of model predictive control to control the entire inverter circuit[1]. The simulation model of the inverter system is built in Matlab/Simulink software. It is convenient to control the grid-connected current, suppress the unbalance of the midpoint potential and reduce the switching frequency by changing the weight coefficient in the cost function. The superiority of the model predictive control in the control method of the inverter system is verified.

  4. Global exponential stability of neutral high-order stochastic Hopfield neural networks with Markovian jump parameters and mixed time delays.

    PubMed

    Huang, Haiying; Du, Qiaosheng; Kang, Xibing

    2013-11-01

    In this paper, a class of neutral high-order stochastic Hopfield neural networks with Markovian jump parameters and mixed time delays is investigated. The jumping parameters are modeled as a continuous-time finite-state Markov chain. At first, the existence of equilibrium point for the addressed neural networks is studied. By utilizing the Lyapunov stability theory, stochastic analysis theory and linear matrix inequality (LMI) technique, new delay-dependent stability criteria are presented in terms of linear matrix inequalities to guarantee the neural networks to be globally exponentially stable in the mean square. Numerical simulations are carried out to illustrate the main results. © 2013 ISA. Published by ISA. All rights reserved.

  5. Electronic properties of disordered Weyl semimetals at charge neutrality

    NASA Astrophysics Data System (ADS)

    Holder, Tobias; Huang, Chia-Wei; Ostrovsky, Pavel M.

    2017-11-01

    Weyl semimetals have been intensely studied as a three-dimensional realization of a Dirac-like excitation spectrum where the conduction bands and valence bands touch at isolated Weyl points in momentum space. Like in graphene, this property entails various peculiar electronic properties. However, recent theoretical studies have suggested that resonant scattering from rare regions can give rise to a nonzero density of states even at charge neutrality. Here, we give a detailed account of this effect and demonstrate how the semimetallic nature is suppressed at the lowest scales. To this end, we develop a self-consistent T -matrix approach to investigate the density of states beyond the limit of weak disorder. Our results show a nonvanishing density of states at the Weyl point, which exhibits a nonanalytic dependence on the impurity density. This unusually strong effect of rare regions leads to a revised estimate for the conductivity close to the Weyl point and emphasizes possible deviations from semimetallic behavior in dirty Weyl semimetals at charge neutrality even with very low impurity concentration.

  6. Impressions of functional food consumers.

    PubMed

    Saher, Marieke; Arvola, Anne; Lindeman, Marjaana; Lähteenmäki, Liisa

    2004-02-01

    Functional foods provide a new way of expressing healthiness in food choices. The objective of this study was to apply an indirect measure to explore what kind of impressions people form of users of functional foods. Respondents (n=350) received one of eight versions of a shopping list and rated the buyer of the foods on 66 bipolar attributes on 7-point scales. The shopping lists had either healthy or neutral background items, conventional or functional target items and the buyer was described either as a 40-year-old woman or man. The attribute ratings revealed three factors: disciplined, innovative and gentle. Buyers with healthy background items were perceived as more disciplined than those having neutral items on the list, users of functional foods were rated as more disciplined than users of conventional target items only when the background list consisted of neutral items. Buyers of functional foods were regarded as more innovative and less gentle, but gender affected the ratings on gentle dimension. The impressions of functional food users clearly differ from those formed of users of conventional foods with a healthy image. The shopping list method performed well as an indirect method, but further studies are required to test its feasibility in measuring other food-related impressions.

  7. Analysis of Delamination Growth from Matrix Cracks in Laminates Subjected to Bending Loads

    NASA Technical Reports Server (NTRS)

    Murri, G. B.; Guynn, E. G.

    1986-01-01

    A major source of delamination damage in laminated composite materials is from low-velocity impact. In thin composite laminates under point loads, matrix cracks develop first in the plies, and delaminations then grow from these cracks at the ply interfaces. The purpose of this study was to quantify the combined effects of bending and transverse shear loads on delamination initiation from matrix cracks. Graphite-epoxy laminates with 90 deg. plies on the outside were used to provide a two-dimensional simulation of the damage due to low-velocity impact. Three plate bending problems were considered: a 4-point bending, 3-point bending, and an end-clamped center-loaded plate. Under bending, a matrix crack will form on the tension side of the laminate, through the outer 90 deg. plies and parallel to the fibers. Delaminations will then grow in the interface between the cracked 90 deg. ply and the next adjacent ply. Laminate plate theory was used to derive simple equations relating the total strain energy release rate, G, associated with the delamination growth from a 90 deg. ply crack to the applied bending load and laminate stiffness properties. Three different lay-ups were tested and results compared. Test results verified that the delamination always formed at the interface between the cracked 90 deg. ply and the next adjacent ply. Calculated values for total G sub c from the analysis showed good agreement for all configurations. The analysis was able to predict the delamination onset load for the cases considered. The result indicated that the opening mode component (Mode I) for delamination growth from a matrix crack may be much larger than the component due to interlaminar shear (Mode II).

  8. Response of a Rotating Propeller to Aerodynamic Excitation

    NASA Technical Reports Server (NTRS)

    Arnoldi, Walter E.

    1949-01-01

    The flexural vibration of a rotating propeller blade with clamped shank is analyzed with the object of presenting, in matrix form, equations for the elastic bending moments in forced vibration resulting from aerodynamic forces applied at a fixed multiple of rotational speed. Matrix equations are also derived which define the critical speeds end mode shapes for any excitation order and the relation between critical speed and blade angle. Reference is given to standard works on the numerical solution of matrix equations of the forms derived. The use of a segmented blade as an approximation to a continuous blade provides a simple means for obtaining the matrix solution from the integral equation of equilibrium, so that, in the numerical application of the method presented, the several matrix arrays of the basic physical characteristics of the propeller blade are of simple form, end their simplicity is preserved until, with the solution in sight, numerical manipulations well-known in matrix algebra yield the desired critical speeds and mode shapes frame which the vibration at any operating condition may be synthesized. A close correspondence between the familiar Stodola method and the matrix method is pointed out, indicating that any features of novelty are characteristic not of the analytical procedure but only of the abbreviation, condensation, and efficient organization of the numerical procedure made possible by the use of classical matrix theory.

  9. Actuator development for the Instrument Pointing System (IPS)

    NASA Technical Reports Server (NTRS)

    Suttner, K.

    1984-01-01

    The mechanisms of the instrument pointing system (IPS) are described. Particular emphasis is placed on the actuators which are necessary for operating the IPS. The actuators are described as follows: (1) two linear actuators that clamp the gimbals down during ascent and descent; (2) two linear actuators that attach the payload to the IPS during the mission, and release it into the payload clamps; (3) one rotational actuator that opens and closes the payload clamps; and (4) three identical drive units that represent the three orthogonal gimbal axes and are the prime movers for pointing. Design features, manufacturing problems, test performance, and results are presented.

  10. HTS techniques for patch clamp-based ion channel screening - advances and economy.

    PubMed

    Farre, Cecilia; Fertig, Niels

    2012-06-01

    Ten years ago, the first publication appeared showing patch clamp recordings performed on a planar glass chip instead of using a conventional patch clamp pipette. "Going planar" proved to revolutionize ion channel drug screening as we know it, by allowing high quality measurements of ion channels and their effectors at a higher throughput and at the same time de-skilling the highly laborious technique. Over the years, platforms evolved in response to user requirements regarding experimental features, data handling plus storage, and suitable target diversity. This article gives a snapshot image of patch clamp-based ion channel screening with focus on platforms developed to meet requirements of high-throughput screening environments. The commercially available platforms are described, along with their benefits and drawbacks in ion channel drug screening. Automated patch clamp (APC) platforms allow faster investigation of a larger number of ion channel active compounds or cell clones than previously possible. Since patch clamp is the only method allowing direct, real-time measurements of ion channel activity, APC holds the promise of picking up high quality leads, where they otherwise would have been overseen using indirect methods. In addition, drug candidate safety profiling can be performed earlier in the drug discovery process, avoiding late-phase compound withdrawal due to safety liability issues, which is highly costly and inefficient.

  11. Ion channel drug discovery and research: the automated Nano-Patch-Clamp technology.

    PubMed

    Brueggemann, A; George, M; Klau, M; Beckler, M; Steindl, J; Behrends, J C; Fertig, N

    2004-01-01

    Unlike the genomics revolution, which was largely enabled by a single technological advance (high throughput sequencing), rapid advancement in proteomics will require a broader effort to increase the throughput of a number of key tools for functional analysis of different types of proteins. In the case of ion channels -a class of (membrane) proteins of great physiological importance and potential as drug targets- the lack of adequate assay technologies is felt particularly strongly. The available, indirect, high throughput screening methods for ion channels clearly generate insufficient information. The best technology to study ion channel function and screen for compound interaction is the patch clamp technique, but patch clamping suffers from low throughput, which is not acceptable for drug screening. A first step towards a solution is presented here. The nano patch clamp technology, which is based on a planar, microstructured glass chip, enables automatic whole cell patch clamp measurements. The Port-a-Patch is an automated electrophysiology workstation, which uses planar patch clamp chips. This approach enables high quality and high content ion channel and compound evaluation on a one-cell-at-a-time basis. The presented automation of the patch process and its scalability to an array format are the prerequisites for any higher throughput electrophysiology instruments.

  12. Renal Vascular Clamp Placement: A Potential Cause of Incomplete Hilar Control during Partial Nephrectomy.

    PubMed

    Tryon, David; Myklak, Kristene; Alsyouf, Muhannad; Conceicao, Carol; Peplinski, Brandon; Arenas, Javier L; Faaborg, Daniel; Ruckle, Herbert C; Baldwin, D Duane

    2016-03-01

    Previous benchtop studies have shown that robotic bulldog clamps provide incomplete vascular control of a Penrose drain. We determined the efficacy of robotic and laparoscopic bulldog clamps to ensure hemostasis on the human renal artery. The effect of clamp position on vascular control was also examined. Fresh human cadaveric renal arteries were used to determine the leak point pressure of 7 bulldog clamps from a total of 3 manufacturers. Five trials were performed per clamp at 4 locations, including the fulcrum, proximal, middle and distal positions. Comparison was done using the Kruskal-Wallis test with p <0.05 considered significant. None of the bulldog clamps leaked at a pressure less than 215 mm Hg when applied at the proximal, middle or distal position. In general leak point pressure decreased as the artery was positioned more distal along the clamp. The exception was when the vessel was placed at the fulcrum position. At that position 80% to 100% of trials with the Klein laparoscopic, 100% with the Klein robotic (Klein Robotic, San Antonio, Texas) and 60% to 80% with the Scanlan robotic (Scanlan International, Saint Paul, Minnesota) clamp leaked at pressure below 215 mm Hg. Each vascular clamp adequately occluded flow at physiological pressure when placed at the proximal, middle or distal position. Furthermore, these results demonstrate that there is leakage at physiological pressure when the artery is placed at the fulcrum of certain clamp types. These results suggest that applying a bulldog clamp at the fulcrum could potentially lead to inadequate vessel occlusion and intraoperative bleeding. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Neutralization, by a monospecific Bothrops lanceolatus antivenom, of toxic activities induced by homologous and heterologous Bothírops snake venoms.

    PubMed

    Bogarín, G; Romero, M; Rojas, G; Lutsch, C; Casadamont, M; Lang, J; Otero, R; Gutiérrez, J M

    1999-03-01

    A monospecific Bothrops lanceolatus antivenom, currently used in Martinique, was tested for its efficacy in the neutralization of several toxic and enzymatic activities of the venoms of B. lanceolatus, B. atrox and B. asper. When tested by the i.p. route in mice, B. lanceolatus venom had an LD50 of 12.8 microg/g. In addition, it induced local tissue damage (hemorrhage, edema and myotoxicity) and showed indirect hemolytic activity, but was devoid of coagulant effect on human plasma in vitro and of defibrinating activity in mice. Antivenom was fully effective in the neutralization of lethal, hemorrhagic, edema-forming, myotoxic and indirect hemolytic effects of B. lanceolatus venom in assays involving preincubation of venom and antivenom. When tested against the venoms of B. asper and B. atrox, the antivenom completely neutralized the lethal, hemorrhagic, myotoxic and indirect hemolytic effects, and was partially effective in neutralizing edema-forming activity. In contrast, the antivenom was ineffective in the neutralization of in vitro coagulant and in vivo defibrinating effects induced by these two venoms.

  14. Scattering matrix approach to the dissociative recombination of HCO{sup +} and N{sub 2}H{sup +}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fonseca dos Santos, S.; Douguet, N.; Orel, A. E.

    We present a theoretical study of the indirect dissociative recombination of linear polyatomic ions at low collisional energies. The approach is based on the computation of the scattering matrix just above the ionization threshold and enables the explicit determination of all diabatic electronic couplings responsible for dissociative recombination. In addition, we use the multi-channel quantum-defect theory to demonstrate the precision of the scattering matrix by reproducing accurately ab initio Rydberg state energies of the neutral molecule. We consider the molecular ions N{sub 2}H{sup +} and HCO{sup +} as benchmark systems of astrophysical interest and improve former theoretical studies, which hadmore » repeatedly produced smaller cross sections than experimentally measured. Specifically, we demonstrate the crucial role of the previously overlooked stretching modes for linear polyatomic ions with large permanent dipole moment. The theoretical cross sections for both ions agree well with experimental data over a wide energy range. Finally, we consider the potential role of the HOC{sup +} isomer in the experimental cross sections of HCO{sup +} at energies below 10 meV.« less

  15. Urinary urea nitrogen excretion during the hyperinsulinemic euglycemic clamp in type 1 diabetic patients and healthy subjects.

    PubMed

    Wohl, P; Krusinová, E; Klementová, M; Wohl, P; Kratochvílová, S; Pelikánová, T

    2008-01-01

    The hyperinsulinemic euglycemic clamp (HEC) combined with indirect calorimetry (IC) is used for estimation of insulin-stimulated substrate utilization. Calculations are based on urinary urea nitrogen excretion (UE), which is influenced by correct urine collection. The aims of our study were to improve the timing of urine collection during the clamp and to test the effect of insulin on UE in patients with type 1 diabetes (DM1; n=11) and healthy subjects (C; n=11). Urine samples were collected (a) over 24 h divided into 3-h periods and (b) before and during two-step clamp (1 and 10 mIU.kg(-1).min(-1); period 1 and period 2) combined with IC. The UE during the clamp was corrected for changes in urea pool size (UEc). There were no significant differences in 24-h UE between C and DM1 and no circadian variation in UE in either group. During the clamp, serum urea decreased significantly in both groups (p<0.01). Therefore, UEc was significantly lower as compared to UE not adjusted for changes in urea pool size both in C (p<0.001) and DM1 (p<0.001). While UE did not change during the clamp, UEc decreased significantly in both groups (p<0.01). UEc during the clamp was significantly higher in DM1 compared to C both in period 1 (p<0.05) and period 2 (p<0.01). The UE over 24 h and UEc during the clamp were statistically different in both C and DM1. We conclude that urine collection performed during the clamp with UE adjusted for changes in urea pool size is the most suitable technique for measuring substrate utilization during the clamp both in DM1 and C. Urine collections during the clamp cannot be replaced either by 24-h sampling (periods I-VII) or by a single 24-h urine collection. Attenuated insulin-induced decrease in UEc in DM1 implicates the impaired insulin effect on proteolysis.

  16. Indirect contributions to electron-impact ionization of Li+ (1 s 2 s S31 ) ions: Role of intermediate double-K -vacancy states

    NASA Astrophysics Data System (ADS)

    Müller, A.; Borovik, A.; Huber, K.; Schippers, S.; Fursa, D. V.; Bray, I.

    2018-02-01

    Fine details of the cross section for electron-impact ionization of metastable two-electron Li+(1 s 2 s S31) ions are scrutinized by both experiment and theory. Beyond direct knockoff ionization, indirect ionization mechanisms proceeding via formation of intermediate double-K-vacancy (hollow) states either in a Li+ ion or in a neutral lithium atom and subsequent emission of one or two electrons, respectively, can contribute to the net production of Li2 + ions. The partial cross sections for such contributions are less than 4% of the total single-ionization cross section. The characteristic steps, resonances, and interference phenomena in the indirect ionization contribution are measured with an experimental energy spread of less than 0.9 eV and with a statistical relative uncertainty of the order of 1.7%, requiring a level of statistical uncertainty in the total single-ionization cross section of better than 0.05%. The measurements are accompanied by convergent-close-coupling calculations performed on a fine energy grid. Theory and experiment are in remarkable agreement concerning the fine details of the ionization cross section. Comparison with previous R-matrix results is less favorable.

  17. Validation of simple indexes to assess insulin sensitivity during pregnancy in Wistar and Sprague-Dawley rats.

    PubMed

    Cacho, J; Sevillano, J; de Castro, J; Herrera, E; Ramos, M P

    2008-11-01

    Insulin resistance plays a role in the pathogenesis of diabetes, including gestational diabetes. The glucose clamp is considered the gold standard for determining in vivo insulin sensitivity, both in human and in animal models. However, the clamp is laborious, time consuming and, in animals, requires anesthesia and collection of multiple blood samples. In human studies, a number of simple indexes, derived from fasting glucose and insulin levels, have been obtained and validated against the glucose clamp. However, these indexes have not been validated in rats and their accuracy in predicting altered insulin sensitivity remains to be established. In the present study, we have evaluated whether indirect estimates based on fasting glucose and insulin levels are valid predictors of insulin sensitivity in nonpregnant and 20-day-pregnant Wistar and Sprague-Dawley rats. We have analyzed the homeostasis model assessment of insulin resistance (HOMA-IR), the quantitative insulin sensitivity check index (QUICKI), and the fasting glucose-to-insulin ratio (FGIR) by comparing them with the insulin sensitivity (SI(Clamp)) values obtained during the hyperinsulinemic-isoglycemic clamp. We have performed a calibration analysis to evaluate the ability of these indexes to accurately predict insulin sensitivity as determined by the reference glucose clamp. Finally, to assess the reliability of these indexes for the identification of animals with impaired insulin sensitivity, performance of the indexes was analyzed by receiver operating characteristic (ROC) curves in Wistar and Sprague-Dawley rats. We found that HOMA-IR, QUICKI, and FGIR correlated significantly with SI(Clamp), exhibited good sensitivity and specificity, accurately predicted SI(Clamp), and yielded lower insulin sensitivity in pregnant than in nonpregnant rats. Together, our data demonstrate that these indexes provide an easy and accurate measure of insulin sensitivity during pregnancy in the rat.

  18. Variable-speed wind power system with improved energy capture via multilevel conversion

    DOEpatents

    Erickson, Robert W.; Al-Naseem, Osama A.; Fingersh, Lee Jay

    2005-05-31

    A system and method for efficiently capturing electrical energy from a variable-speed generator are disclosed. The system includes a matrix converter using full-bridge, multilevel switch cells, in which semiconductor devices are clamped to a known constant DC voltage of a capacitor. The multilevel matrix converter is capable of generating multilevel voltage wave waveform of arbitrary magnitude and frequencies. The matrix converter can be controlled by using space vector modulation.

  19. Reliability analysis of laminated CMC components through shell subelement techniques

    NASA Technical Reports Server (NTRS)

    Starlinger, Alois; Duffy, Stephen F.; Gyekenyesi, John P.

    1992-01-01

    An updated version of the integrated design program Composite Ceramics Analysis and Reliability Evaluation of Structures (C/CARES) was developed for the reliability evaluation of ceramic matrix composites (CMC) laminated shell components. The algorithm is now split into two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The interface program creates a neutral data base which is then read by the reliability module. This neutral data base concept allows easy data transfer between different computer systems. The new interface program from the finite-element code Matrix Automated Reduction and Coupling (MARC) also includes the option of using hybrid laminates (a combination of plies of different materials or different layups) and allows for variations in temperature fields throughout the component. In the current version of C/CARES, a subelement technique was implemented, enabling stress gradients within an element to be taken into account. The noninteractive reliability function is now evaluated at each Gaussian integration point instead of using averaging techniques. As a result of the increased number of stress evaluation points, considerable improvements in the accuracy of reliability analyses were realized.

  20. A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

    DOE PAGES

    Duman, Turgay; Marti, Shilpa; Moonem, M. A.; ...

    2017-05-17

    A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter.more » N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.« less

  1. A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duman, Turgay; Marti, Shilpa; Moonem, M. A.

    A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter.more » N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.« less

  2. An analysis of the wear behavior of SiC whisker reinforced alumina from 25 to 1200 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher

    1991-01-01

    A model is described for predicting the wear behavior of whisker reinforced ceramics. The model was successfully applied to a silicon carbide whisker reinforced alumina ceramic composite subjected to sliding contact. The model compares the friction forces on the whiskers due to sliding, which act to pull or push them out of the matrix, to the clamping or compressive forces on the whiskers due to the matrix, which act to hold the whiskers in the composite. At low temperatures, the whiskers are held strongly in the matrix and are fractured into pieces during the wear process along with the matrix. At elevated temperatures differential thermal expansion between the whiskers and matrix can cause loosening of the whiskers and lead to pullout during the wear process and to higher wear. The model, which represents the combination of elastic stress analysis and a friction heating analysis, predicts a transition temperature at which the strength of the whiskers equals the clamping force holding them in the matrix. Above the transition the whiskers are pulled out of the matrix during sliding, and below the transition the whiskers are simply fractured. The existence of the transition gives rise to a dual wear mode or mechanism behavior for this material which was observed in laboratory experiments. The results from this model correlate well with experimentally observed behavior indicating that the model may be useful in obtaining a better understanding of material behavior and in making material improvements.

  3. An analysis of the wear behavior of SiC whisker-reinforced alumina from 25 to 1200 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher

    1993-01-01

    A model is described for predicting the wear behavior of whisker reinforced ceramics. The model was successfully applied to a silicon carbide whisker reinforced alumina ceramic composite subjected to sliding contact. The model compares the friction forces on the whiskers due to sliding, which act to pull or push them out of the matrix, to the clamping or compressive forces on the whiskers due to the matrix, which act to hold the whiskers in the composite. At low temperatures, the whiskers are held strongly in the matrix and are fractured into pieces during the wear process along with the matrix. At elevated temperatures differential thermal expansion between the whiskers and matrix can cause loosening of the whiskers and lead to pullout during the wear process and to higher wear. The model, which represents the combination of elastic stress analysis and a friction heating analysis, predicts a transition temperature at which the strength of the whiskers equals the clamping force holding them in the matrix. Above the transition the whiskers are pulled out of the matrix during sliding, and below the transition the whiskers are simply fractured. The existence of the transition gives rise to a dual wear mode or mechanism behavior for this material which was observed in laboratory experiments. The results from this model correlate well with experimentally observed behavior indicating that the model may be useful in obtaining a better understanding of material behavior and in making material improvements.

  4. Niflumic acid alters gating of HCN2 pacemaker channels by interaction with the outer region of S4 voltage sensing domains.

    PubMed

    Cheng, Lan; Sanguinetti, Michael C

    2009-05-01

    Niflumic acid, 2-[[3-(trifluoromethyl)phenyl]amino]pyridine-3-carboxylic acid (NFA), is a nonsteroidal anti-inflammatory drug that also blocks or modifies the gating of many ion channels. Here, we investigated the effects of NFA on hyperpolarization-activated cyclic nucleotide-gated cation (HCN) pacemaker channels expressed in X. laevis oocytes using site-directed mutagenesis and the two-electrode voltage-clamp technique. Extracellular NFA acted rapidly and caused a slowing of activation and deactivation and a hyperpolarizing shift in the voltage dependence of HCN2 channel activation (-24.5 +/- 1.2 mV at 1 mM). Slowed channel gating and reduction of current magnitude was marked in oocytes treated with NFA, while clamped at 0 mV but minimal in oocytes clamped at -100 mV, indicating the drug preferentially interacts with channels in the closed state. NFA at 0.1 to 3 mM shifted the half-point for channel activation in a concentration-dependent manner, with an EC(50) of 0.54 +/- 0.068 mM and a predicted maximum shift of -38 mV. NFA at 1 mM also reduced maximum HCN2 conductance by approximately 20%, presumably by direct block of the pore. The rapid onset and state-dependence of NFA-induced changes in channel gating suggests an interaction with the extracellular region of the S4 transmembrane helix, the primary voltage-sensing domain of HCN2. Neutralization (by mutation to Gln) of any three of the outer four basic charged residues in S4, but not single mutations, abrogated the NFA-induced shift in channel activation. We conclude that NFA alters HCN2 gating by interacting with the extracellular end of the S4 voltage sensor domains.

  5. (Evaluation of neutralizing ability of four commercially available antivenoms against the venom of Bothrops asper from Costa Rica)

    PubMed

    Bogarín, G; Segura, E; Durán, G; Lomonte, B; Rojas, G; Gutiérrez, J M

    1995-09-01

    We studied the ability of four commercially available antivenoms to neutralize several toxic and enzymatic activities of Bothrops asper (terciopelo) venom from Costa Rica. Experiments with preincubation of venom and antivenom were carried out to test the neutralization of lethal, hemorrhagic, coagulant and indirect hemolytic activities. In addition, antibody titers against crude venom and myotoxin II purified from this venom were determined by enzyme immunoassay (ELISA). Results indicate that polyvalent antivenom from Instituto Clodomiro Picado (Costa Rica) has the highest neutralizing ability against lethal, coagulant and indirect hemolytic activities, whereas MYN polyvalent antivenom (México) has the highest neutralization against hemorrhagic activity. Antivenom from Instituto Clodomiro Picado also has the highest antibody titers against crude B. asper venom and against myotoxin II. Antivenoms from Universidad Central de Venezuela (Venezuela), Vencofarma (Brazil) and MYN (México) failed to neutralize the lethal effect of this venom. These results stress the need for rigorous quality control systems to evaluate the neutralizing ability of antivenoms in Central America.

  6. Weighted augmented Jacobian matrix with a variable coefficient method for kinematics mapping of space teleoperation based on human-robot motion similarity

    NASA Astrophysics Data System (ADS)

    Shi, Zhong; Huang, Xuexiang; Hu, Tianjian; Tan, Qian; Hou, Yuzhuo

    2016-10-01

    Space teleoperation is an important space technology, and human-robot motion similarity can improve the flexibility and intuition of space teleoperation. This paper aims to obtain an appropriate kinematics mapping method of coupled Cartesian-joint space for space teleoperation. First, the coupled Cartesian-joint similarity principles concerning kinematics differences are defined. Then, a novel weighted augmented Jacobian matrix with a variable coefficient (WAJM-VC) method for kinematics mapping is proposed. The Jacobian matrix is augmented to achieve a global similarity of human-robot motion. A clamping weighted least norm scheme is introduced to achieve local optimizations, and the operating ratio coefficient is variable to pursue similarity in the elbow joint. Similarity in Cartesian space and the property of joint constraint satisfaction is analysed to determine the damping factor and clamping velocity. Finally, a teleoperation system based on human motion capture is established, and the experimental results indicate that the proposed WAJM-VC method can improve the flexibility and intuition of space teleoperation to complete complex space tasks.

  7. Estimating the Cost of Early Infant Male Circumcision in Zimbabwe: Results From a Randomized Noninferiority Trial of AccuCirc Device Versus Mogen Clamp.

    PubMed

    Mangenah, Collin; Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M; Thirumurthy, Harsha

    2015-08-15

    Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization.

  8. A proposed route to independent measurements of tight junction conductance at discrete cell junctions

    PubMed Central

    Zhou, Lushan; Zeng, Yuhan; Baker, Lane A; Hou, Jianghui

    2015-01-01

    Direct recording of tight junction permeability is of pivotal importance to many biologic fields. Previous approaches bear an intrinsic disadvantage due to the difficulty of separating tight junction conductance from nearby membrane conductance. Here, we propose the design of Double whole-cell Voltage Clamp - Ion Conductance Microscopy (DVC-ICM) based on previously demonstrated potentiometric scanning of local conductive pathways. As proposed, DVC-ICM utilizes two coordinated whole-cell patch-clamps to neutralize the apical membrane current during potentiometric scanning, which in models described here will profoundly enhance the specificity of tight junction recording. Several potential pitfalls are considered, evaluated and addressed with alternative countermeasures. PMID:26716077

  9. Predicting nitrogen loading with land-cover composition: how can watershed size affect model performance?

    PubMed

    Zhang, Tao; Yang, Xiaojun

    2013-01-01

    Watershed-wide land-cover proportions can be used to predict the in-stream non-point source pollutant loadings through regression modeling. However, the model performance can vary greatly across different study sites and among various watersheds. Existing literature has shown that this type of regression modeling tends to perform better for large watersheds than for small ones, and that such a performance variation has been largely linked with different interwatershed landscape heterogeneity levels. The purpose of this study is to further examine the previously mentioned empirical observation based on a set of watersheds in the northern part of Georgia (USA) to explore the underlying causes of the variation in model performance. Through the combined use of the neutral landscape modeling approach and a spatially explicit nutrient loading model, we tested whether the regression model performance variation over the watershed groups ranging in size is due to the different watershed landscape heterogeneity levels. We adopted three neutral landscape modeling criteria that were tied with different similarity levels in watershed landscape properties and used the nutrient loading model to estimate the nitrogen loads for these neutral watersheds. Then we compared the regression model performance for the real and neutral landscape scenarios, respectively. We found that watershed size can affect the regression model performance both directly and indirectly. Along with the indirect effect through interwatershed heterogeneity, watershed size can directly affect the model performance over the watersheds varying in size. We also found that the regression model performance can be more significantly affected by other physiographic properties shaping nitrogen delivery effectiveness than the watershed land-cover heterogeneity. This study contrasts with many existing studies because it goes beyond hypothesis formulation based on empirical observations and into hypothesis testing to explore the fundamental mechanism.

  10. History of Childhood Maltreatment and College Academic Outcomes: Indirect Effects of Hot Execution Function

    PubMed Central

    Welsh, Marilyn C.; Peterson, Eric; Jameson, Molly M.

    2017-01-01

    College students who report a history of childhood maltreatment may be at risk for poor outcomes. In the current study, we conducted an exploratory analysis to examine potential models that statistically mediate associations between aspects of maltreatment and aspects of academic outcome, with a particular focus on executive functions (EF). Consistent with contemporary EF research, we distinguished between relatively “cool” EF tasks (i.e., performed in a context relatively free of emotional or motivational valence) and “hot” EF tasks that emphasize performance under more emotionally arousing conditions. Sixty-one male and female college undergraduates self-reported childhood maltreatment history (emotional abuse and neglect, physical abuse and neglect, and sexual abuse) on the Childhood Trauma Questionnaire (CTQ), and were given two EF measures: (1) Go-No-Go (GNG) test that included a Color Condition (cool); Neutral Face Condition (warm); and Emotion Face condition (hot), and (2) Iowa Gambling Task (IGT), a measure of risky decision making that reflects hot EF. Academic outcomes were: (1) grade point average (GPA: first-semester, cumulative, and semester concurrent with testing), and (2) Student Adaptation to College Questionnaire (SACQ). Correlational patterns suggested two EF scores as potential mediators: GNG reaction time (RT) in the Neutral Face condition, and IGT Block 2 adaptive responding. Indirect effects analyses indicated that IGT Block 2 adaptive responding has an indirect effect on the relationship between CTQ Total score and 1st semester GPA, and between CTQ Emotional Abuse and concurrent GPA. Regarding college adaptation, we identified a consistent indirect effect of GNG Neutral Face RT on the relationship between CTQ Emotional Neglect and SACQ total, academic, social, and personal–emotional adaption scores. Our results demonstrate that higher scores on a child maltreatment history self-report negatively predict college academic outcomes as assessed by GPA and by self-reported adaptation. Further, relatively “hot” EF task performance on the IGT and GNG tasks serves as a link between child maltreatment experiences and college achievement and adaptation, suggesting that hot EF skills may be a fruitful direction for future intervention efforts to improve academic outcomes for this population. PMID:28725204

  11. [Analysis of brain hemometabolism behavior during carotid endarterectomy with temporary clamping.].

    PubMed

    Duval Neto, Gastão Fernandes; Niencheski, Augusto H

    2004-04-01

    Carotid endarterectomy with temporary clamping changes cerebral blood flow and cerebral metabolic oxygen demand ratio with consequent oligemic hypoxia or hemometabolic uncoupling. This study aimed at identifying changes in brain hemometabolism, evaluated through changes in oxyhemoglobin saturation in internal jugular vein bulb (SvjO2) during carotid endarterectomy with clamping, and at correlating these changes with potentially interfering factors, mainly end tidal CO2 pressure (P ET CO2) and cerebral perfusion pressure (CPP). Sixteen patients with unilateral carotid stenotic disease scheduled to carotid endarterectomy with carotid arterial clamping were enrolled in this study. Parameters including internal jugular bulb oxyhemoglobin saturation, stump pressure and end tidal CO2 pressure were measured at the following moments: M1 - pre-clamping; M2 - 3 minutes after clamping; M3 - pre-unclamping; M4 - post-unclamping). The comparison among SvjO2 (%, mean +/- SD) in all studied periods has shown differences between those recorded in moments M1 (52.25 +/- 7.87) and M2 (47.43 +/- 9.19). This initial decrease stabilized during temporary clamping, showing decrease in the comparison between M2 and M3 (46.56 +/- 9.25), without statistical significance (p = ns). At post-unclamping, M4 (47.68 +/- 9.12), SvjO2 was increased as compared to M2 and M3 clamping stages, however it was still lower than that of pre-clamping stage M1.(M4 x M1 - p < 0.04) This SvjO2 decrease was followed by significant cerebral perfusion pressure (stump pressure) decrease. Factors influencing this brain hemometabolic uncoupling trend were correlated to P ET CO2. The comparison between CPP and SvjO2 showed weak correlation devoid of statistical significance. In the conditions of our study, SvjO2 measurement is a fast and effective way of clinically monitoring changes in CBF/CMRO2 ratio. Temporary carotid clamping implies in a trend towards brain hemometabolic uncoupling and, as a consequence, to oligemic ischemia; cerebral perfusion pressure does not assesses brain hemometabolic status (CBF and CMRO2 ratio); hypocapnia, may lead to brain hemometabolic uncoupling; P ET CO2 monitoring is an innocuous and efficient way to indirectly monitor PaCO2 preventing inadvertent hypocapnia and its deleterious effects on CBF/CMRO2 ratio during temporary carotid clamping.

  12. CPDES3: A preconditioned conjugate gradient solver for linear asymmetric matrix equations arising from coupled partial differential equations in three dimensions

    NASA Astrophysics Data System (ADS)

    Anderson, D. V.; Koniges, A. E.; Shumaker, D. E.

    1988-11-01

    Many physical problems require the solution of coupled partial differential equations on three-dimensional domains. When the time scales of interest dictate an implicit discretization of the equations a rather complicated global matrix system needs solution. The exact form of the matrix depends on the choice of spatial grids and on the finite element or finite difference approximations employed. CPDES3 allows each spatial operator to have 7, 15, 19, or 27 point stencils and allows for general couplings between all of the component PDE's and it automatically generates the matrix structures needed to perform the algorithm. The resulting sparse matrix equation is solved by either the preconditioned conjugate gradient (CG) method or by the preconditioned biconjugate gradient (BCG) algorithm. An arbitrary number of component equations are permitted only limited by available memory. In the sub-band representation used, we generate an algorithm that is written compactly in terms of indirect induces which is vectorizable on some of the newer scientific computers.

  13. CPDES2: A preconditioned conjugate gradient solver for linear asymmetric matrix equations arising from coupled partial differential equations in two dimensions

    NASA Astrophysics Data System (ADS)

    Anderson, D. V.; Koniges, A. E.; Shumaker, D. E.

    1988-11-01

    Many physical problems require the solution of coupled partial differential equations on two-dimensional domains. When the time scales of interest dictate an implicit discretization of the equations a rather complicated global matrix system needs solution. The exact form of the matrix depends on the choice of spatial grids and on the finite element or finite difference approximations employed. CPDES2 allows each spatial operator to have 5 or 9 point stencils and allows for general couplings between all of the component PDE's and it automatically generates the matrix structures needed to perform the algorithm. The resulting sparse matrix equation is solved by either the preconditioned conjugate gradient (CG) method or by the preconditioned biconjugate gradient (BCG) algorithm. An arbitrary number of component equations are permitted only limited by available memory. In the sub-band representation used, we generate an algorithm that is written compactly in terms of indirect indices which is vectorizable on some of the newer scientific computers.

  14. Fault-Tolerant Control of ANPC Three-Level Inverter Based on Order-Reduction Optimal Control Strategy under Multi-Device Open-Circuit Fault.

    PubMed

    Xu, Shi-Zhou; Wang, Chun-Jie; Lin, Fang-Li; Li, Shi-Xiang

    2017-10-31

    The multi-device open-circuit fault is a common fault of ANPC (Active Neutral-Point Clamped) three-level inverter and effect the operation stability of the whole system. To improve the operation stability, this paper summarized the main solutions currently firstly and analyzed all the possible states of multi-device open-circuit fault. Secondly, an order-reduction optimal control strategy was proposed under multi-device open-circuit fault to realize fault-tolerant control based on the topology and control requirement of ANPC three-level inverter and operation stability. This control strategy can solve the faults with different operation states, and can works in order-reduction state under specific open-circuit faults with specific combined devices, which sacrifices the control quality to obtain the stability priority control. Finally, the simulation and experiment proved the effectiveness of the proposed strategy.

  15. Theoretical study of solvent effects on the electronic coupling matrix elements in rigidly linked donor-acceptor systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cave, R.J.; Newton, M.D.; Kumar, K.

    1995-12-07

    The recently developed generalized Mulliken-Hush approach for the calculation of the electronic coupling matrix element for electron-transfer processes is applied to two rigidly linked donor-bridge-acceptor systems having dimethoxyanthracene as the donor and a dicarbomethoxycyclobutene unit as the acceptor. The dependence of the electronic coupling matrix element as a function of bridge type is examined with and without solvent molecules present. For clamp-shaped bridge structures solvent can have a dramatic effect on the electronic coupling matrix element. The behavior with variation of solvent is in good agreement with that observed experimentally for these systems. 23 refs., 2 tabs.

  16. Estimating the Cost of Early Infant Male Circumcision in Zimbabwe: Results From a Randomized Noninferiority Trial of AccuCirc Device Versus Mogen Clamp

    PubMed Central

    Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K.; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M.; Thirumurthy, Harsha

    2015-01-01

    Background: Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Methods: Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. Results: The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. Conclusions: EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization. PMID:26017658

  17. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    NASA Astrophysics Data System (ADS)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  18. Tribologic analyses of a self-mated aluminium contact used for overhead transmission lines

    NASA Astrophysics Data System (ADS)

    Steier, V. Franco

    2017-05-01

    The lifetime of aluminium components is often limited to their poor wear resistance. One example for such aluminium applications are overhead transmission lines. The sore points of these lines are the segments where the aluminium conductors are fixed to the line supports. The fixation is commonly realized via aluminium suspension clamps. Here, a superposition of different loads like traction and bending stresses, clamping forces and different types of wear occurs. To investigate the wear behaviour in these peculiar points, tribologic model tests were carried out. Within the tests, overhead conductor wires and aluminium plates, extracted from suspension clamps were reciprocally slid against aluminium plates (cylinder-on-plate test). The COF and a wear related parameter were recorded constantly. Subsequently, the loaded surfaces were analysed using confocal laser and electron scanning microscopy as well as energy dispersive X-ray spectroscopy. The investigation detected the formation of an oxidized tribologic layer between both components. The tribolayer, which mayor part adhered on the suspension clamps, was mostly formed from material removed from the conductor wires.

  19. Performance of Four-Leg VSC based DSTATCOM using Single Phase P-Q Theory

    NASA Astrophysics Data System (ADS)

    Jampana, Bangarraju; Veramalla, Rajagopal; Askani, Jayalaxmi

    2017-02-01

    This paper presents single-phase P-Q theory for four-leg VSC based distributed static compensator (DSTATCOM) in the distribution system. The proposed DSTATCOM maintains unity power factor at source, zero voltage regulation, eliminates current harmonics, load balancing and neutral current compensation. The advantage of using four-leg VSC based DSTATCOM is to eliminate isolated/non-isolated transformer connection at point of common coupling (PCC) for neutral current compensation. The elimination of transformer connection at PCC with proposed topology will reduce cost of DSTATCOM. The single-phase P-Q theory control algorithm is used to extract fundamental component of active and reactive currents for generation of reference source currents which is based on indirect current control method. The proposed DSTATCOM is modelled and the results are validated with various consumer loads under unity power factor and zero voltage regulation modes in the MATLAB R2013a environment using simpower system toolbox.

  20. Melatonin mediates vasodilation through both direct and indirect activation of BKCa channels.

    PubMed

    Zhao, T; Zhang, H; Jin, C; Qiu, F; Wu, Y; Shi, L

    2017-10-01

    Melatonin, synthesized primarily by the pineal gland, is a neuroendocrine hormone with high membrane permeability. The vascular effects of melatonin, including vasoconstriction and vasodilation, have been demonstrated in numerous studies. However, the mechanisms underlying these effects are not fully understood. Large-conductance Ca 2+ -activated K + (BK Ca ) channels are expressed broadly on smooth muscle cells and play an important role in vascular tone regulation. This study explored the mechanisms of myocyte BK Ca channels and endothelial factors underlying the action of melatonin on the mesenteric arteries (MAs). Vascular contractility and patch-clamp studies were performed on myocytes of MAs from Wistar rats. Melatonin induced significant vasodilation on MAs. In the presence of N ω -nitro-l-arginine methyl ester (l-NAME), a potent endothelial oxide synthase (eNOS) inhibitor, melatonin elicited concentration-dependent relaxation, with lowered pIC 50 The effect of melatonin was significantly attenuated in the presence of BK Ca channel blocker iberiotoxin or MT1/MT2 receptor antagonist luzindole in both (+) l-NAME and (-) l-NAME groups. In the (+) l-NAME group, iberiotoxin caused a parallel rightward shift of the melatonin concentration-relaxation curve, with pIC 50 lower than that of luzindole. Both inside-out and cell-attached patch-clamp recordings showed that melatonin significantly increased the open probability, mean open time and voltage sensitivity of BK Ca channels. In a cell-attached patch-clamp configuration, the melatonin-induced enhancement of BK Ca channel activity was significantly suppressed by luzindole. These findings indicate that in addition to the activation of eNOS, melatonin-induced vasorelaxation of MAs is partially attributable to its direct (passing through the cell membrane) and indirect (via MT1/MT2 receptors) activation of the BK Ca channels on mesenteric arterial myocytes. © 2017 Society for Endocrinology.

  1. Mechanotransduction: all signals point to cytoskeleton, matrix, and integrins

    NASA Technical Reports Server (NTRS)

    Alenghat, Francis J.; Ingber, Donald E.

    2002-01-01

    Mechanical stresses modulate cell function by either activating or tuning signal transduction pathways. Mechanotransduction, the process by which cells convert mechanical stimuli into a chemical response, occurs both in cells specialized for sensing mechanical cues and in parenchymal cells whose primary function is not mechanosensory. However, common among the various responses to mechanical stress is the importance of direct or indirect connections between the internal cytoskeleton, the extracellular matrix (ECM), and traditional signal transducing molecules. In many instances, these elements converge at focal adhesions, sites of structural attachment between the cytoskeleton and ECM that are anchored by cell surface integrin receptors. Alenghat and Ingber discuss the accumulating evidence for the central role of cytoskeleton, ECM, and integrin-anchored focal adhesions in several mechanotransduction pathways.

  2. Regenerator seal design

    DOEpatents

    Eckart, Francis H.

    1982-01-01

    A rotary regenerator disc matrix has a face seal with a cross arm and arcuate rim segments joined by prestress clamps to prestrain the arcuate rim seals so as to compensate seal rim twisting or coning and resultant disc face seal leakage as produced by operating thermal gradients across the seal.

  3. Analysis of impactor residues in tray clamps from the Long Duration Exposure Facility. Part 2: Clamps from Bay B of the satellite

    NASA Technical Reports Server (NTRS)

    Bernhard, Ronald P.; Zolensky, Michael E.

    1994-01-01

    The Long Duration Exposure Facility (LDEF) was placed in low-Earth orbit (LEO) in 1984 and recovered 5.7 years later. The LDEF was host to several individual experiments specifically designed to characterize critical aspects of meteoroid and debris environment in LEO. However, it was realized from the beginning that the most efficient use of the satellite would be to examine the entire surface for impact features. In this regard, particular interest centered on common exposed materials that faced in all LDEF pointing directions. Among the most important of these materials was the tray clamps. Therefore, in an effort to better understand the nature of particulates in LEO and their effects on spacecraft hardware, residues found in impact features on LDEF tray clamp surfaces are being analyzed. This catalog presents all data from clamps from Bay B of the LDEF. NASA Technical Memorandum 104759 has cataloged impacts that occurred on Bay B (published March 1993). Subsequent catalogs will include clamps from succeeding bays of the satellite.

  4. Serum IgG titres, but not avidity, correlates with neutralizing antibody response after H5N1 vaccination.

    PubMed

    Pedersen, Gabriel Kristian; Höschler, Katja; Øie Solbak, Sara Marie; Bredholt, Geir; Pathirana, Rishi Delan; Afsar, Aram; Breakwell, Lucy; Nøstbakken, Jane Kristin; Raae, Arnt Johan; Brokstad, Karl Albert; Sjursen, Haakon; Zambon, Maria; Cox, Rebecca Jane

    2014-07-31

    Influenza H5N1 virus constitutes a pandemic threat and development of effective H5N1 vaccines is a global priority. Anti-influenza antibodies directed towards the haemagglutinin (HA) define a correlate of protection. Both antibody concentration and avidity may be important for virus neutralization and resolving influenza disease. We conducted a phase I clinical trial of a virosomal H5N1 vaccine adjuvanted with the immunostimulating complex Matrix M™. Sixty adults were intramuscularly immunized with two vaccine doses (21 days apart) of 30 μg HA alone or 1.5, 7.5 or 30 μg HA adjuvanted with Matrix M™. Serum H5 HA1-specific antibodies and virus neutralization were determined at days 0, 21, 42, 180 and 360 and long-term memory B cells at day 360 post-vaccination. The binding of the HA specific antibodies was measured by avidity NaSCN-elution ELISA and surface plasmon resonance (SPR). The H5 HA1-specific IgG response peaked after the second dose (day 42), was dominated by IgG1 and IgG3 and was highest in the adjuvanted vaccine groups. IgG titres correlated significantly with virus neutralization at all time points (Spearman r≥0.66, p<0.0001). By elution ELISA, serum antibody avidity was highest at days 180 and 360 post vaccination and did not correlate with virus neutralization. Long-lasting H5 HA1-specific memory B cells produced high IgG antibody avidity similar to serum IgG. Maturation of serum antibody avidity continued up to day 360 after influenza H5N1 vaccination. Virus neutralization correlated with serum H5 HA1-specific IgG antibody concentrations and not antibody avidity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Shape memory alloy wires turn composites into smart structures: II. Manufacturing and properties

    NASA Astrophysics Data System (ADS)

    Michaud, Veronique J.; Schrooten, Jan; Parlinska, Magdelena; Gotthardt, Rolf; Bidaux, Jacques-Eric

    2002-07-01

    The manufacturing route and resulting properties of adaptive composites are presented in the second part of this European project report. Manufacturing was performed using a specially designed frame to pre-strain the SMA wires, embed them into Kevlar-epoxy prepregs, and maintain them during the curing process in an autoclave. Composite compounds were then tested for strain response, recovery stress response in a clamped-clamped configuration, as well as vibrational response. Through the understanding of the transformational behavior of constrained SMA wires, interesting and unique functional properties of SMA composites could be measured, explained and modeled. Large recovery stresses and as a consequence, a change in vibrational response in a clamped- clamped condition, or a reversible shape change in a free standing condition, could be generated by the SMA composites in a controllable way. These properties were dependent on composite design aspects and exhibited a reproducible and stable behavior, provided that the properties of the matrix, of the wires and the processing route were carefully optimized. In conclusion, the achievements of this effort in areas such as thermomechanics, transformational and vibrational behavior and durability of SMA based composites provide a first step towards a reliable materials design, and potentially an industrial application.

  6. Improving TWSTFT short-term stability by network time transfer.

    PubMed

    Tseng, Wen-Hung; Lin, Shinn-Yan; Feng, Kai-Ming; Fujieda, M; Maeno, H

    2010-01-01

    Two-way satellite time and frequency transfer (TWSTFT) is one of the major techniques to compare the atomic time scales between timing laboratories. As more and more TWSTFT measurements have been performed, the large number of point-to-point 2-way time transfer links has grown to be a complex network. For future improvement of the TWSTFT performance, it is important to reduce measurement noise of the TWSTFT results. One method is using TWSTFT network time transfer. The Asia-Pacific network is an exceptional case of simultaneous TWSTFT measurements. Some indirect links through relay stations show better shortterm stabilities than the direct link because the measurement noise may be neutralized in a simultaneous measurement network. In this paper, the authors propose a feasible method to improve the short-term stability by combining the direct and indirect links in the network. Through the comparisons of time deviation (TDEV), the results of network time transfer exhibit clear improved short-term stabilities. For the links used to compare 2 hydrogen masers, the average gain of TDEV at averaging times of 1 h is 22%. As TWSTFT short-term stability can be improved by network time transfer, the network may allow a larger number of simultaneously transmitting stations.

  7. Attitude control of an orbiting space vehicle.

    NASA Technical Reports Server (NTRS)

    Sutherlin, D. W.; Boland, J. S. , III; Borelli, M. T.

    1971-01-01

    Study of the normal and clamped modes of operation and dynamic response characteristics of the gimbaled control moment gyro (CMG) designed to fulfill the stringent pointing requirements of the Skylab telescope mount when the spacecraft is under the influence of both external and internal torques. The results indicate that the clamped mode of operation provides a feasible approach for significantly improving the system characteristics.

  8. Sudan stain of fecal fat: new insight into an old test.

    PubMed

    Khouri, M R; Huang, G; Shiau, Y F

    1989-02-01

    The 72-h fecal fat determination is used as the gold standard to document the presence of steatorrhea. Although the Sudan stain for fecal fat is advocated as a sensitive screening test, a quantitative correlation between the 72-h fecal fat quantitation and the fecal Sudan stain is lacking. This study was designed to examine the staining properties of different classes of purified lipids in an experimentally defined artificial matrix, and to elucidate the reasons for the lack of quantitative correlation between these two tests. Our results indicate that the "neutral fat" stain without acidification or heating identifies triglyceride; and at an appropriate pH, the "neutral stain" also identifies fatty acid. The "split fat" stain with acidification and heating identifies both triglyceride and fatty acid. After acidification, fatty acid soaps are converted to the nonionized fatty acid. Thus, fatty acid soaps can be identified indirectly as fat droplets that are stained by the split fat stain. Although cholesterol is stained with Sudan stain after heating, upon cooling, cholesterol forms crystals of anhydrous cholesterol, making its staining pattern distinct. Neither the neutral fat nor the split fat stain can detect phospholipid or cholesteryl ester. The 72-h fecal fat determination is a measure of the total fatty acid content after a specimen is saponified. The resulting fatty acids are derived from a variety of endogenous and exogenous sources, including free fatty acids, soaps of fatty acids, triglycerides, cholesterol esters, and phospholipids. Therefore, the 72-h fecal fat quantitation does not differentiate between the primary sources of the measured fatty acid. It is concluded that the 72-h fecal fat determination is not specific for documenting triglyceride (fat) malabsorption. Until new methods are developed that specifically measure fecal triglyceride and fatty acid, the Sudan stain of fecal fat appears to be a more specific method for detecting the presence of triglyceride and fatty acid in a matrix.

  9. Least Squares Solution of Small Sample Multiple-Master PSInSAR System

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Ding, Xiao Li; Lu, Zhong

    2010-03-01

    In this paper we propose a least squares based approach for multi-temporal SAR interferometry that allows to estimate the deformation rate with no need of phase unwrapping. The approach utilizes a series of multi-master wrapped differential interferograms with short baselines and only focuses on the arcs constructed by two nearby points at which there are no phase ambiguities. During the estimation an outlier detector is used to identify and remove the arcs with phase ambiguities, and pseudoinverse of priori variance component matrix is taken as the weight of correlated observations in the model. The parameters at points can be obtained by an indirect adjustment model with constraints when several reference points are available. The proposed approach is verified by a set of simulated data.

  10. Y3Fe5O12/Na,Bi,Sr-doped PZT particulate magnetoelectric composites

    NASA Astrophysics Data System (ADS)

    Lisnevskaya, I. V.; Bobrova, I. A.; Lupeiko, T. G.; Agamirzoeva, M. R.; Myagkaya, K. V.

    2016-05-01

    Magnetoelectric (ME) composites of Na, Bi, Sr substituted lead zirconate titanate (PZT) and yttrium iron garnet having representative formula (100-x) wt% Na,Bi,Sr-doped PZT (PZTNB-1)+x wt% Y3Fe5O12 (YIG) with x=10-90 were manufactured using powdered components obtained through sol-gel processes. It is shown that the decrease in sintering temperature provided by the use of finely dispersed PZTNB-1 and YIG powders allows to significantly reduce content of fluorite-like foreign phase based on zirconium oxide, which forms due to the interfacial interaction during heat treatment and becomes stabilized by yttrium oxide. Connectivity has considerable effect on the value of ME coefficient of composite ceramics. With the same x value, ΔE/ΔH characteristic decreases when changing from 0-3-type structured composites (PZT grains embedded in ferrite matrix) to 3-3-(interpenetrating network of two phases) and especially 3-0-type samples (YIG grains embedded in PZT matrix); in the last case this can be attributed to the substrate clamping effect when ferrite grains are clamped with piezoelectric matrix. ΔE/ΔH value of 0-3 composites with x=40-60 wt% was found to be ∼1.6 mV/(cm Oe).

  11. Experimental and numerical analysis of clamped joints in front motorbike suspensions

    NASA Astrophysics Data System (ADS)

    Croccolo, D.; de Agostinis, M.; Vincenzi, N.

    2010-06-01

    Clamped joints are shaft-hub connections used, as an instance, in front motorbike suspensions to lock the steering plates with the legs and the legs with the wheel pin, by means of one or two bolts. The preloading force, produced during the tightening process, should be evaluated accurately, since it must lock safely the shaft, without overcoming the yielding point of the hub. Firstly, friction coefficients have been evaluated on “ad-hoc designed” specimens, by applying the Design of Experiment approach: the applied tightening torque has been precisely related to the imposed preloading force. Then, the tensile state of clamps have been evaluated both via FEM and by leveraging some design formulae proposed by the Authors as function of the preloading force and of the clamp geometry. Finally, the results have been compared to those given by some strain gauges applied on the tested clamps: the discrepancies between numerical analyses, the design formulae and the experimental results remains under a threshold of 10%.

  12. Neutral evolution of mutational robustness

    PubMed Central

    van Nimwegen, Erik; Crutchfield, James P.; Huynen, Martijn

    1999-01-01

    We introduce and analyze a general model of a population evolving over a network of selectively neutral genotypes. We show that the population’s limit distribution on the neutral network is solely determined by the network topology and given by the principal eigenvector of the network’s adjacency matrix. Moreover, the average number of neutral mutant neighbors per individual is given by the matrix spectral radius. These results quantify the extent to which populations evolve mutational robustness—the insensitivity of the phenotype to mutations—and thus reduce genetic load. Because the average neutrality is independent of evolutionary parameters—such as mutation rate, population size, and selective advantage—one can infer global statistics of neutral network topology by using simple population data available from in vitro or in vivo evolution. Populations evolving on neutral networks of RNA secondary structures show excellent agreement with our theoretical predictions. PMID:10449760

  13. Friction in Forming of UD Composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sachs, U.; Haanappel, S. P.; Akkerman, R.

    2011-05-04

    Inter-ply and tool/ply friction play a dominant role in hot stamp forming of UD fiber-reinforced thermoplastic laminates. This research treats friction measurements of a PEEK-AS4 composite system. To this end, an in-house developed friction tester is utilized to pull a laminate through two heat controlled clamping platens. The friction coefficient is determined by relating the clamp force to the pull force. The geometry of the gap between the clamping platens is monitored with micrometer accuracy. A first approach to describe the relation between the geometry and frictional behavior is undertaken by applying a standard thin-film theory for hydrodynamic lubrication. Experimentalmore » measurements showed that the thin-film theory does not entirely cover the underlying physics. Thus a second model is utilized, which employs a Leonov-model to describe the shear deformation of the matrix material, while its viscosity is described with a multi-mode Maxwell model. The combination of both models shows the potential to capture the complete frictional behavior.« less

  14. In-vitro neurotoxicity of two Malaysian krait species (Bungarus candidus and Bungarus fasciatus) venoms: neutralization by monovalent and polyvalent antivenoms from Thailand.

    PubMed

    Rusmili, Muhamad Rusdi Ahmad; Yee, Tee Ting; Mustafa, Mohd Rais; Othman, Iekhsan; Hodgson, Wayne C

    2014-03-12

    Bungarus candidus and Bungarus fasciatus are two species of krait found in Southeast Asia. Envenoming by these snakes is often characterized by neurotoxicity and, without treatment, causes considerable morbidity and mortality. In this study, the in vitro neurotoxicity of each species, and the effectiveness of two monovalent antivenoms and a polyvalent antivenom, against the neurotoxic effects of the venoms, were examined in a skeletal muscle preparation. Both venoms caused concentration-dependent inhibition of indirect twitches, and attenuated responses to exogenous nicotinic receptor agonists, in the chick biventer preparation, with B. candidus venom being more potent than B. fasciatus venom. SDS-PAGE and western blot analysis indicated different profiles between the venoms. Despite these differences, most proteins bands were recognized by all three antivenoms. Antivenom, added prior to the venoms, attenuated the neurotoxic effect of the venoms. Interestingly, the respective monovalent antivenoms did not neutralize the effects of the venom from the other Bungarus species indicating a relative absence of cross-neutralization. Addition of a high concentration of polyvalent antivenom, at the t90 time point after addition of venom, partially reversed the neurotoxicity of B. fasciatus venom but not B. candidus venom. The monovalent antivenoms had no significant effect when added at the t90 time point. This study showed that B. candidus and B. fasciatus venoms display marked in vitro neurotoxicity in the chick biventer preparation and administration of antivenoms at high dose is necessary to prevent or reverse neurotoxicity.

  15. Multivariate Qst–Fst Comparisons: A Neutrality Test for the Evolution of the G Matrix in Structured Populations

    PubMed Central

    Martin, Guillaume; Chapuis, Elodie; Goudet, Jérôme

    2008-01-01

    Neutrality tests in quantitative genetics provide a statistical framework for the detection of selection on polygenic traits in wild populations. However, the existing method based on comparisons of divergence at neutral markers and quantitative traits (Qst–Fst) suffers from several limitations that hinder a clear interpretation of the results with typical empirical designs. In this article, we propose a multivariate extension of this neutrality test based on empirical estimates of the among-populations (D) and within-populations (G) covariance matrices by MANOVA. A simple pattern is expected under neutrality: D = 2Fst/(1 − Fst)G, so that neutrality implies both proportionality of the two matrices and a specific value of the proportionality coefficient. This pattern is tested using Flury's framework for matrix comparison [common principal-component (CPC) analysis], a well-known tool in G matrix evolution studies. We show the importance of using a Bartlett adjustment of the test for the small sample sizes typically found in empirical studies. We propose a dual test: (i) that the proportionality coefficient is not different from its neutral expectation [2Fst/(1 − Fst)] and (ii) that the MANOVA estimates of mean square matrices between and among populations are proportional. These two tests combined provide a more stringent test for neutrality than the classic Qst–Fst comparison and avoid several statistical problems. Extensive simulations of realistic empirical designs suggest that these tests correctly detect the expected pattern under neutrality and have enough power to efficiently detect mild to strong selection (homogeneous, heterogeneous, or mixed) when it is occurring on a set of traits. This method also provides a rigorous and quantitative framework for disentangling the effects of different selection regimes and of drift on the evolution of the G matrix. We discuss practical requirements for the proper application of our test in empirical studies and potential extensions. PMID:18245845

  16. Double-stranded DNA breaks hidden in the neutral Comet assay suggest a role of the sperm nuclear matrix in DNA integrity maintenance

    PubMed Central

    Ribas-Maynou, J.; Gawecka, J.E.; Benet, J.; Ward, W.S.

    2014-01-01

    We used a mouse model in which sperm DNA damage was induced to understand the relationship of double-stranded DNA (dsDNA) breaks to sperm chromatin structure and to the Comet assay. Sperm chromatin fragmentation (SCF) produces dsDNA breaks located on the matrix attachment regions, between protamine toroids. In this model, epididymal sperm induced to undergo SCF can religate dsDNA breaks while vas deferens sperm cannot. Here, we demonstrated that the conventional neutral Comet assay underestimates the epididymal SCF breaks because the broken DNA ends remain attached to the nuclear matrix, causing the DNA to remain associated with the dispersion halo, and the Comet tails to be weak. Therefore, we term these hidden dsDNA breaks. When the Comet assay was modified to include an additional incubation with sodium dodecyl sulfate (SDS) and dithiothreitol (DTT) after the conventional lysis, thereby solubilizing the nuclear matrix, the broken DNA was released from the matrix, which resulted in a reduction of the sperm head halo and an increase in the Comet tail length, exposing the hidden dsDNA breaks. Conversely, SCF-induced vas deferens sperm had small halos and long tails with the conventional neutral Comet assay, suggesting that the broken DNA ends were not tethered to the nuclear matrix. These results suggest that the attachment to the nuclear matrix is crucial for the religation of SCF-induced DNA breaks in sperm. Our data suggest that the neutral Comet assay identifies only dsDNA breaks that are released from the nuclear matrix and that the addition of an SDS treatment can reveal these hidden dsDNA breaks. PMID:24282283

  17. Double-stranded DNA breaks hidden in the neutral Comet assay suggest a role of the sperm nuclear matrix in DNA integrity maintenance.

    PubMed

    Ribas-Maynou, J; Gawecka, J E; Benet, J; Ward, W S

    2014-04-01

    We used a mouse model in which sperm DNA damage was induced to understand the relationship of double-stranded DNA (dsDNA) breaks to sperm chromatin structure and to the Comet assay. Sperm chromatin fragmentation (SCF) produces dsDNA breaks located on the matrix attachment regions, between protamine toroids. In this model, epididymal sperm induced to undergo SCF can religate dsDNA breaks while vas deferens sperm cannot. Here, we demonstrated that the conventional neutral Comet assay underestimates the epididymal SCF breaks because the broken DNA ends remain attached to the nuclear matrix, causing the DNA to remain associated with the dispersion halo, and the Comet tails to be weak. Therefore, we term these hidden dsDNA breaks. When the Comet assay was modified to include an additional incubation with sodium dodecyl sulfate (SDS) and dithiothreitol (DTT) after the conventional lysis, thereby solubilizing the nuclear matrix, the broken DNA was released from the matrix, which resulted in a reduction of the sperm head halo and an increase in the Comet tail length, exposing the hidden dsDNA breaks. Conversely, SCF-induced vas deferens sperm had small halos and long tails with the conventional neutral Comet assay, suggesting that the broken DNA ends were not tethered to the nuclear matrix. These results suggest that the attachment to the nuclear matrix is crucial for the religation of SCF-induced DNA breaks in sperm. Our data suggest that the neutral Comet assay identifies only dsDNA breaks that are released from the nuclear matrix and that the addition of an SDS treatment can reveal these hidden dsDNA breaks.

  18. Indirect fabrication of multiple post-and-core patterns with a vinyl polysiloxane matrix.

    PubMed

    Sabbak, Sahar Asaad

    2002-11-01

    In the described technique, a vinyl polysiloxane material is used as a matrix for the indirect fabrication of multiple custom-cast posts and cores. The matrix technique enables the clinician to fabricate multiple posts and cores in a short period of time. The form, harmony, and common axis of preparation for all cores are well controlled before the definitive crown/fixed partial denture restorations are fabricated. Oral tissues are not exposed to the heat of polymerization or the excess monomer of the resin material when this technique is used.

  19. Ion-to-Neutral Ratios and Thermal Proton Transfer in Matrix-Assisted Laser Desorption/Ionization

    NASA Astrophysics Data System (ADS)

    Lu, I.-Chung; Chu, Kuan Yu; Lin, Chih-Yuan; Wu, Shang-Yun; Dyakov, Yuri A.; Chen, Jien-Lian; Gray-Weale, Angus; Lee, Yuan-Tseh; Ni, Chi-Kung

    2015-07-01

    The ion-to-neutral ratios of four commonly used solid matrices, α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (2,5-DHB), sinapinic acid (SA), and ferulic acid (FA) in matrix-assisted laser desorption/ionization (MALDI) at 355 nm are reported. Ions are measured using a time-of-flight mass spectrometer combined with a time-sliced ion imaging detector. Neutrals are measured using a rotatable quadrupole mass spectrometer. The ion-to-neutral ratios of CHCA are three orders of magnitude larger than those of the other matrices at the same laser fluence. The ion-to-neutral ratios predicted using the thermal proton transfer model are similar to the experimental measurements, indicating that thermal proton transfer reactions play a major role in generating ions in ultraviolet-MALDI.

  20. Simultaneous spatiotemporal mapping of in situ pH and bacterial activity within an intact 3D microcolony structure

    NASA Astrophysics Data System (ADS)

    Hwang, Geelsu; Liu, Yuan; Kim, Dongyeop; Sun, Victor; Aviles-Reyes, Alejandro; Kajfasz, Jessica K.; Lemos, Jose A.; Koo, Hyun

    2016-09-01

    Biofilms are comprised of bacterial-clusters (microcolonies) enmeshed in an extracellular matrix. Streptococcus mutans can produce exopolysaccharides (EPS)-matrix and assemble microcolonies with acidic microenvironments that can cause tooth-decay despite the surrounding neutral-pH found in oral cavity. How the matrix influences the pH and bacterial activity locally remains unclear. Here, we simultaneously analyzed in situ pH and gene expression within intact biofilms and measured the impact of damage to the surrounding EPS-matrix. The spatiotemporal changes of these properties were characterized at a single-microcolony level following incubation in neutral-pH buffer. The middle and bottom-regions as well as inner-section within the microcolony 3D structure were resistant to neutralization (vs. upper and peripheral-region), forming an acidic core. Concomitantly, we used a green fluorescent protein (GFP) reporter to monitor expression of the pH-responsive atpB (PatpB::gfp) by S. mutans within microcolonies. The atpB expression was induced in the acidic core, but sharply decreased at peripheral/upper microcolony regions, congruent with local pH microenvironment. Enzymatic digestion of the surrounding matrix resulted in nearly complete neutralization of microcolony interior and down-regulation of atpB. Altogether, our data reveal that biofilm matrix facilitates formation of an acidic core within microcolonies which in turn activates S. mutans acid-stress response, mediating both the local environment and bacterial activity in situ.

  1. Requirements of frictional debonding at fiber/matrix interfaces for tough ceramic composites

    NASA Astrophysics Data System (ADS)

    Hsueh, Chun-Hway

    1992-11-01

    Optimum toughening of fiber-reinforced ceramic composites requires debonding at fiber/matrix interfaces and subsequent frictional sliding between the fibers and the matrix as the main crack extends through the composite. Criteria of both interfacial debonding vs fiber fracture, and frictional debonding vs frictionless debonding, are illustrated. To achieve interfacial debonding, the ratio of the fiber strength to the interfacial shear strength must exceed a critical value; to achieve a frictional interface after interfacial debonding, the ratio of the interfacial residual clamping stress to the interfacial shear strength must also exceed a critical value. While interfacial debonding is not sensitive to Poisson's effect, the frictional interface is sensitive to Poisson's effect.

  2. Tumor evolution: Linear, branching, neutral or punctuated?☆

    PubMed Central

    Davis, Alexander; Gao, Ruli; Navin, Nicholas

    2017-01-01

    Intratumor heterogeneity has been widely reported in human cancers, but our knowledge of how this genetic diversity emerges over time remains limited. A central challenge in studying tumor evolution is the difficulty in collecting longitudinal samples from cancer patients. Consequently, most studies have inferred tumor evolution from single time-point samples, providing very indirect information. These data have led to several competing models of tumor evolution: linear, branching, neutral and punctuated. Each model makes different assumptions regarding the timing of mutations and selection of clones, and therefore has different implications for the diagnosis and therapeutic treatment of cancer patients. Furthermore, emerging evidence suggests that models may change during tumor progression or operate concurrently for different classes of mutations. Finally, we discuss data that supports the theory that most human tumors evolve from a single cell in the normal tissue. This article is part of a Special Issue entitled: Evolutionary principles - heterogeneity in cancer?, edited by Dr. Robert A. Gatenby. PMID:28110020

  3. LabPatch, an acquisition and analysis program for patch-clamp electrophysiology.

    PubMed

    Robinson, T; Thomsen, L; Huizinga, J D

    2000-05-01

    An acquisition and analysis program, "LabPatch," has been developed for use in patch-clamp research. LabPatch controls any patch-clamp amplifier, acquires and records data, runs voltage protocols, plots and analyzes data, and connects to spreadsheet and database programs. Controls within LabPatch are grouped by function on one screen, much like an oscilloscope front panel. The software is mouse driven, so that the user need only point and click. Finally, the ability to copy data to other programs running in Windows 95/98, and the ability to keep track of experiments using a database, make LabPatch extremely versatile. The system requirements include Windows 95/98, at least a 100-MHz processor and 16 MB RAM, a data acquisition card, digital-to-analog converter, and a patch-clamp amplifier. LabPatch is available free of charge at http://www.fhs.mcmaster.ca/huizinga/.

  4. Vibration of a spatial elastica constrained inside a straight tube

    NASA Astrophysics Data System (ADS)

    Chen, Jen-San; Fang, Joyce

    2014-04-01

    In this paper we study the dynamic behavior of a clamped-clamped spatial elastica under edge thrust constrained inside a straight cylindrical tube. Attention is focused on the calculation of the natural frequencies and mode shapes of the planar and spatial one-point-contact deformations. The main issue in determining the natural frequencies of a constrained rod is the movement of the contact point during vibration. In order to capture the physical essence of the contact-point movement, an Eulerian description of the equations of motion based on director theory is formulated. After proper linearization of the equations of motion, boundary conditions, and contact conditions, the natural frequencies and mode shapes of the elastica can be obtained by solving a system of eighteen first-order differential equations with shooting method. It is concluded that the planar one-point-contact deformation becomes unstable and evolves to a spatial deformation at a bifurcation point in both displacement and force control procedures.

  5. First observation of the fourth neutral polarization point in the atmosphere

    NASA Astrophysics Data System (ADS)

    Horvath, Gabor; Bernath, Balazs; Suhai, Bence; Barta, Andras; Wehner, Rudiger

    2002-10-01

    In the clear sky there are three commonly known loci, the Arago, Babinet, and Brewster neutral points, where the skylight is unpolarized. These peculiar celestial points, bearing the names of their discoverers, have been the subject of many ground-based investigations, because their positions are sensitive indicators of the amount and type of atmospheric turbidity. According to theoretical considerations and computer simulations, there should exist an additional neutral point approximately opposite to the Babinet point, which can be observed only at higher altitudes in the air or space. Until now, this anonymous fourth neutral point has not been observed during air- or space-borne polarimetric experiments and has been forgotten, in spite of the fact that the neutral points were a basic tool in atmospheric research for a century. Here, we report on the first observation of this fourth neutral point from a hot air balloon. Using 180-field-of-view imaging polarimetry, we could observe the fourth neutral point at 450, 550, and 650 nm from different altitudes between 900 and 3500 m during and after sunrise at approximately 2240 below the anti-solar point along the anti-solar meridian, depending on the wavelength and solar elevation. We show that the fourth neutral point exists at the expected location and has characteristics similar to those of the Arago, Babinet, and Brewster points. We discuss why the fourth neutral point has not been observed in previous air- or space-borne polarimetric experiments. 2002 Optical Society of America

  6. Implicit method for the computation of unsteady flows on unstructured grids

    NASA Technical Reports Server (NTRS)

    Venkatakrishnan, V.; Mavriplis, D. J.

    1995-01-01

    An implicit method for the computation of unsteady flows on unstructured grids is presented. Following a finite difference approximation for the time derivative, the resulting nonlinear system of equations is solved at each time step by using an agglomeration multigrid procedure. The method allows for arbitrarily large time steps and is efficient in terms of computational effort and storage. Inviscid and viscous unsteady flows are computed to validate the procedure. The issue of the mass matrix which arises with vertex-centered finite volume schemes is addressed. The present formulation allows the mass matrix to be inverted indirectly. A mesh point movement and reconnection procedure is described that allows the grids to evolve with the motion of bodies. As an example of flow over bodies in relative motion, flow over a multi-element airfoil system undergoing deployment is computed.

  7. Design of three-well indirect pumping terahertz quantum cascade lasers for high optical gain based on nonequilibrium Green's function analysis

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Kubis, Tillmann; Jie Wang, Qi; Klimeck, Gerhard

    2012-03-01

    The nonequilibrium Green's function approach is applied to the design of three-well indirect pumping terahertz (THz) quantum cascade lasers (QCLs) based on a resonant phonon depopulation scheme. The effects of the anticrossing of the injector states and the dipole matrix element of the laser levels on the optical gain of THz QCLs are studied. The results show that a design that results in a more pronounced anticrossing of the injector states will achieve a higher optical gain in the indirect pumping scheme compared to the traditional resonant-tunneling injection scheme. This offers in general a more efficient coherent resonant-tunneling transport of electrons in the indirect pumping scheme. It is also shown that, for operating temperatures below 200 K and low lasing frequencies, larger dipole matrix elements, i.e., vertical optical transitions, offer a higher optical gain. In contrast, in the case of high lasing frequencies, smaller dipole matrix elements, i.e., diagonal optical transitions are better for achieving a higher optical gain.

  8. Hyperammonaemia, plasma aminoacid imbalance, and blood-brain aminoacid transport: a unified theory of portal-systemic encephalopathy.

    PubMed

    James, J H; Ziparo, V; Jeppsson, B; Fischer, J E

    1979-10-13

    It is proposed that hyperammonaemia in liver cirrhosis or after portacaval shunt contributes to plasma neutral aminoacid imbalance and to increased activity of the blood-brain neutral amino-acid transport system. Plasma neutral aminoacid concentrations are deranged, partly, but not completely, because ammonia stimulates glucagon secretion; a high rate of gluconeogenesis and hyperinsulinaemia follow. Brain uptake of neutral aminoacids rises because ammonia stimulates brain-glutamine synthesis, which results in rapid exchange of brain glutamine for plasma neutral aminoacids. Hyperammonaemia therefore contributes to encephalopathy indirectly, by raising the brain concentration of neutral aminoacids which after neurotransmitter metabolism, rather than directly, by toxic effects on neuronal metabolism.

  9. Design and simulation of control algorithms for stored energy and plasma current in non-inductive scenarios on NSTX-U

    NASA Astrophysics Data System (ADS)

    Boyer, Mark; Andre, Robert; Gates, David; Gerhardt, Stefan; Menard, Jonathan; Poli, Francesca

    2015-11-01

    One of the major goals of NSTX-U is to demonstrate non-inductive operation. To facilitate this and other program goals, the center stack has been upgraded and a second neutral beam line has been added with three sources aimed more tangentially to provide higher current drive efficiency and the ability to shape the current drive profile. While non-inductive start-up and ramp-up scenarios are being developed, initial non-inductive studies will likely rely on clamping the Ohmic coil current after the plasma current has been established inductively. In this work the ability to maintain control of stored energy and plasma current once the Ohmic coil has been clamped is explored. The six neutral beam sources and the mid-plane outer gap of the plasma are considered as actuators. System identification is done using TRANSP simulations in which the actuators are modulated around a reference shot. The resulting reduced model is used to design an optimal control law with anti-windup and a recently developed framework for closed loop simulations in TRANSP is used to test the control. Limitations due to actuator saturation are assessed and robustness to beam modulation, changes in the plasma density and confinement, and changes in density and temperature profile shapes are studied. Supported by US DOE contract DE-AC02-09CH11466.

  10. Neutral points of skylight polarization observed during the total eclipse on 11 August 1999.

    PubMed

    Horváth, Gábor; Pomozi, István; Gál, József

    2003-01-20

    We report here on the observation of unpolarized (neutral) points in the sky during the total solar eclipse on 11 August 1999. Near the zenith a neutral point was observed at 450 nm at two different points of time during totality. Around this celestial point the distribution of the angle of polarization was heterogeneous: The electric field vectors on the one side were approximately perpendicular to those on the other side. At another moment of totality, near the zenith a local minimum of the degree of linear polarization occurred at 550 nm. Near the antisolar meridian, at a low elevation another two neutral points occurred at 450 nm at a certain moment during totality. Approximately at the position of these neutral points, at another moment of totality a local minimum of the degree of polarization occurred at 550 nm, whereas at 450 nm a neutral point was observed, around which the angle-of-polarization pattern was homogeneous: The electric field vectors were approximately horizontal on both sides of the neutral point.

  11. Nonlinear Finite Element Analysis of Metals and Metal Matrix Composites: A Local-Global Investigation

    DTIC Science & Technology

    1992-10-01

    and SiC/Al [47] possess good chemical bonding and experience mechanical clamping due to the differences in thermal expansion coefficients between...Coefficient of Thermal 2.70 x 10.6 *F-1 4.09 x 10-6 *C-1 Expansion (ca) Poisson’s Ratio (v) 0.25 0.25 Fiber Diameter (d) 0.0056 in 0.014224 cm...Properties of the matrix (as fabricated) Coefficient of Thermal 5.4 x 10-6 "F1 9.72 x 10-6 "C-1 Expansion (a) Poisson’s Ratio (v) 0.351 0.351 Longitudinal

  12. How northward turnings of the IMF can lead to substorm expansion onsets

    NASA Astrophysics Data System (ADS)

    Russell, C. T.

    2000-10-01

    The frequent triggering of the expansion phase of substorms by northward turnings of the interplanetary magnetic field (IMF) can be understood in terms of the existence of two neutral points. The distant neutral point produces a plasma sheet on closed field lines that resupplies the magnetized plasma surrounding the near-Earth neutral point. As long as the near-Earth neutral point reconnects in moderately dense plasma, the reconnection rate is low. When the IMF turns northward, reconnection at the distant neutral point ceases but reconnection at the near-Earth neutral point continues and soon reaches open, low density magnetic field lines where the rate of reconnection is rapid, and a full expansion phase occurs. This model is consistent with the observations of substorms with two onsets: an initial one at low invariant latitudes when reconnection at the near Earth neutral point first begins and the second when reconnection reaches low density field lines at the edge of the plasma sheet and continues into the open flux of the tail lobes. It is also consistent with the occurrence of pseudo breakups in which reconnection at the near Earth neutral point begins but does not proceed to lobe field lines and a full expansion phase.

  13. Origin of terminal voltage variations due to self-mixing in terahertz frequency quantum cascade lasers.

    PubMed

    Grier, Andrew; Dean, Paul; Valavanis, Alexander; Keeley, James; Kundu, Iman; Cooper, Jonathan D; Agnew, Gary; Taimre, Thomas; Lim, Yah Leng; Bertling, Karl; Rakić, Aleksandar D; Li, Lianhe H; Harrison, Paul; Linfield, Edmund H; Ikonić, Zoran; Davies, A Giles; Indjin, Dragan

    2016-09-19

    We explain the origin of voltage variations due to self-mixing in a terahertz (THz) frequency quantum cascade laser (QCL) using an extended density matrix (DM) approach. Our DM model allows calculation of both the current-voltage (I-V) and optical power characteristics of the QCL under optical feedback by changing the cavity loss, to which the gain of the active region is clamped. The variation of intra-cavity field strength necessary to achieve gain clamping, and the corresponding change in bias required to maintain a constant current density through the heterostructure is then calculated. Strong enhancement of the self-mixing voltage signal due to non-linearity of the (I-V) characteristics is predicted and confirmed experimentally in an exemplar 2.6 THz bound-to-continuum QCL.

  14. Immunization-elicited Broadly Protective Antibody Reveals Ebolavirus Fusion Loop as a Site of Vulnerability

    PubMed Central

    Zhao, Xuelian; Howell, Katie A.; He, Shihua; Brannan, Jennifer M.; Wec, Anna Z.; Davidson, Edgar; Turner, Hannah L.; Chiang, Chi-I; Lei, Lin; Fels, J. Maximilian; Vu, Hong; Shulenin, Sergey; Turonis, Ashley N.; Kuehne, Ana I.; Liu, Guodong; Ta, Mi; Wang, Yimeng; Sundling, Christopher; Xiao, Yongli; Spence, Jennifer S.; Doranz, Benjamin J.; Holtsberg, Frederick W.; Ward, Andrew B.; Chandran, Kartik; Dye, John M.; Qiu, Xiangguo; Li, Yuxing; Aman, M. Javad

    2018-01-01

    Summary While neutralizing antibodies are highly effective against ebolavirus infections, current experimental ebolavirus vaccines primarily elicit species-specific antibody responses. Here we describe an immunization-elicited macaque antibody (CA45) that clamps the internal fusion loop with the N-terminus of the ebolavirus glycoproteins (GP) and potently neutralizes Ebola, Sudan, Bundibugyo, and Reston viruses. CA45, alone or in combination with an antibody that blocks receptor binding, provided full protection against all pathogenic ebolaviruses in mice, guinea pigs, and ferrets. Analysis of memory B cells from the immunized macaque suggests that elicitation of broadly neutralizing antibodies (bNAbs) for ebolaviruses is possible but difficult, potentially due to the rarity of bNAb clones and their precursors. Unexpectedly, germline-reverted CA45, while exhibiting negligible binding to full-length GP, bound a proteolytically remodeled GP with picomolar affinity, suggesting that engineered ebolavirus vaccines could trigger rare bNAb precursors more robustly. These findings have important implications for developing pan-ebolavirus vaccine and immunotherapeutic cocktails. PMID:28525756

  15. Design of A Grid Integrated PV System with MPPT Control and Voltage Oriented Controller using MATLAB/PLECES

    NASA Astrophysics Data System (ADS)

    Soreng, Bineeta; Behera, Pradyumna; Pradhan, Raseswari

    2017-08-01

    This paper presents model of a grid-integrated photovoltaic array with Maximum Power Point Tracker (MPPT) and voltage oriented controller. The MPPT of the PV array is usually an essential part of PV system as MPPT helps the operating point of the solar array to align its maximum power point. In this model, the MPPT along with a DC-DC converter lets a PV generator to produce continuous power, despite of the measurement conditions. The neutral-point-clamped converter (NPC) with a boost converter raises the voltage from the panels to the DC-link. An LCL-filter smoothens the current ripple caused by the PWM modulation of the grid-side inverter. In addition to the MPPT, the system has two more two controllers, such as voltage controller and a current controller. The voltage control has a PI controller to regulate the PV voltage to optimal level by controlling the amount of current injected into the boost stage. Here, the grid-side converter transfers the power from the DC-link into the grid and maintains the DC-link voltage. Three-phase PV inverters are used for off-grid or designed to create utility frequency AC. The PV system can be connected in series or parallel to get the desired output power. To justify the working of this model, the grid-integrated PV system has been designed in MATLAB/PLECS. The simulation shows the P-V curve of implemented PV Array consisting 4 X 20 modules, reactive, real power, grid voltage and current.

  16. Fundamental Studies of Low Velocity Impact Resistance of Graphite Fiber Reinforced Polymer Matrix Composites. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Bowles, K. J.

    1985-01-01

    A study was conducted to relate the impact resistance of graphite fiber reinforced composites with matrix properties through gaining an understanding of the basic mechanics involved in the deformation and fracture process, and the effect of the polymer matrix structure on these mechanisms. It was found that the resin matrix structure influences the composite impact resistance in at least two ways. The integration of flexibilizers into the polymer chain structure tends to reduce the T sub g and the mechanical properties of the polymer. The reduction in the mechanical properties of the matrix does not enhance the composite impact resistance because it allows matrix controlled failure to initiate impact damage. It was found that when the instrumented dropweight impact tester is used as a means for assessing resin toughness, the resin toughness is enhanced by the ability of the clamped specimen to deflect enough to produce sufficient membrane action to support a significant amount of the load. The results of this study indicate that crossplied composite impact resistance is very much dependent on the matrix mechanical properties.

  17. Control of Grid Connected Photovoltaic System Using Three-Level T-Type Inverter

    NASA Astrophysics Data System (ADS)

    Zorig, Abdelmalik; Belkeiri, Mohammed; Barkat, Said; Rabhi, Abdelhamid

    2016-08-01

    Three-level T-Type inverter (3LT2I) topology has numerous advantageous compared to three-level neutral-point-clamped (NPC) inverter. The main benefits of 3LT2I inverter are the efficiency, inverter cost, switching losses, and the quality of output voltage waveforms. In this paper, a photovoltaic distributed generation system based on dual-stage topology of DC-DC boost converter and 3LT2I is introduced. To that end, a decoupling control strategy of 3LT2I is proposed to control the current injected into the grid, reactive power compensation, and DC-link voltage. The resulting system is able to extract the maximum power from photovoltaic generator, to achieve sinusoidal grid currents, and to ensure reactive power compensation. The voltage-balancing control of two split DC capacitors of the 3LT2I is achieved using three-level space vector modulation with balancing strategy based on the effective use of the redundant switching states of the inverter voltage vectors. The proposed system performance is investigated at different operating conditions.

  18. Design of Low Inductance Switching Power Cell for GaN HEMT Based Inverter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gurpinar, Emre; Iannuzzo, Francesco; Yang, Yongheng

    Here in this paper, an ultra-low inductance power cell is designed for a three-Level Active Neutral Point Clamped (3LANPC) based on 650 V gallium nitride (GaN) HEMT devices. The 3L-ANPC topology with GaN HEMT devices and the selected modulation scheme suitable for wide-bandgap (WBG) devices are presented. The commutation loops, which mainly contribute to voltage overshoots and increase of switching losses, are discussed. The ultra-low inductance power cell design based on a fourlayer Printed Circuit Board (PCB) with the aim to maximize the switching performance of GaN HEMTs is explained. The design of gate drivers for the GaN HEMT devicesmore » is presented. Parasitic inductance and resistance of the proposed design are extracted with finite element analysis and discussed. Common mode behaviours based on the SPICE model of the converter are analyzed. Experimental results on the designed 3L-ANPC with the output power of up to 1 kW are presented, which verifies the performance of the proposed design in terms of ultra-low inductance.« less

  19. A new model predictive control algorithm by reducing the computing time of cost function minimization for NPC inverter in three-phase power grids.

    PubMed

    Taheri, Asghar; Zhalebaghi, Mohammad Hadi

    2017-11-01

    This paper presents a new control strategy based on finite-control-set model-predictive control (FCS-MPC) for Neutral-point-clamped (NPC) three-level converters. Containing some advantages like fast dynamic response, easy inclusion of constraints and simple control loop, makes the FCS-MPC method attractive to use as a switching strategy for converters. However, the large amount of required calculations is a problem in the widespread of this method. In this way, to resolve this problem this paper presents a modified method that effectively reduces the computation load compare with conventional FCS-MPC method and at the same time does not affect on control performance. The proposed method can be used for exchanging power between electrical grid and DC resources by providing active and reactive power compensations. Experiments on three-level converter for three Power Factor Correction (PFC), inductive and capacitive compensation modes verify the good and comparable performance. The results have been simulated using MATLAB/SIMULINK software. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  20. A neutral functional differential equation of Lurie type. [on asymptotic stability of feedback control

    NASA Technical Reports Server (NTRS)

    Chukwu, E. N.

    1980-01-01

    The problem of Lurie is posed for systems described by a functional differential equation of neutral type. Sufficient conditions are obtained for absolute stability for the controlled system if it is assumed that the uncontrolled plant equation is uniformly asymptotically stable. Both the direct and indirect control cases are treated.

  1. A clamping force measurement system for monitoring the condition of bolted joints on railway track joints and points

    NASA Astrophysics Data System (ADS)

    Tesfa, B.; Horler, G.; Thobiani, F. Al; Gu, F.; Ball, A. D.

    2012-05-01

    Many industrial structures associated with railway infrastructures rely on a large number of bolted joint connections to ensure safe and reliable operation of the track and trackside furniture. Significant sums of money are spent annually to repair the damage caused by bolt failures and to maintain the integrity of bolted structures. In the UK, Network Rail (the organization responsible for rail network maintenance and safety) conducts corrective and preventive maintenance manually on 26,000 sets of points (each having approximately 30 bolted joints per set), in order to ensure operational success and safety for the travelling public. Such manual maintenance is costly, disruptive, unreliable and prone to human error. The aim of this work is to provide a means of automatically measuring the clamping force of each individual bolted joint, by means of an instrumented washer. This paper describes the development of a sensor means to be used in the washer, which satisfies the following criteria. Sense changes in the clamping force of the joint and report this fact. Provide compatibility with the large dynamic range of clamping force. Satisfy the limitations in terms of physical size. Provide the means to electronically interface with the washer. Provide a means of powering the washer in situ. Provide a solution at an acceptable cost. Specifically the paper focuses on requirements 1, 2 and 3 and presents the results that support further development of the proposed design and the realization of a pre-prototype system. In the paper, various options for the force sensing element (strain gage, capacitor, piezo-resistive) have been compared, using design optimization techniques. As a result of the evaluation, piezo-resistive sensors in concert with a proprietary force attenuation method, have been found to offer the best performance and cost trade-off The performance of the novel clamping force sensor has been evaluated experimentally and the results show that a smart washer can be developed to monitor the condition of bolted joints as found on railway track and points.

  2. Simplest bifurcation diagrams for monotone families of vector fields on a torus

    NASA Astrophysics Data System (ADS)

    Baesens, C.; MacKay, R. S.

    2018-06-01

    In part 1, we prove that the bifurcation diagram for a monotone two-parameter family of vector fields on a torus has to be at least as complicated as the conjectured simplest one proposed in Baesens et al (1991 Physica D 49 387–475). To achieve this, we define ‘simplest’ by sequentially minimising the numbers of equilibria, Bogdanov–Takens points, closed curves of centre and of neutral saddle, intersections of curves of centre and neutral saddle, Reeb components, other invariant annuli, arcs of rotational homoclinic bifurcation of horizontal homotopy type, necklace points, contractible periodic orbits, points of neutral horizontal homoclinic bifurcation and half-plane fan points. We obtain two types of simplest case, including that initially proposed. In part 2, we analyse the bifurcation diagram for an explicit monotone family of vector fields on a torus and prove that it has at most two equilibria, precisely four Bogdanov–Takens points, no closed curves of centre nor closed curves of neutral saddle, at most two Reeb components, precisely four arcs of rotational homoclinic connection of ‘horizontal’ homotopy type, eight horizontal saddle-node loop points, two necklace points, four points of neutral horizontal homoclinic connection, and two half-plane fan points, and there is no simultaneous existence of centre and neutral saddle, nor contractible homoclinic connection to a neutral saddle. Furthermore, we prove that all saddle-nodes, Bogdanov–Takens points, non-neutral and neutral horizontal homoclinic bifurcations are non-degenerate and the Hopf condition is satisfied for all centres. We also find it has four points of degenerate Hopf bifurcation. It thus provides an example of a family satisfying all the assumptions of part 1 except the one of at most one contractible periodic orbit.

  3. Contribution of thermal energy to initial ion production in matrix-assisted laser desorption/ionization observed with 2,4,6-trihydroxyacetophenone.

    PubMed

    Lai, Yin-Hung; Chen, Bo-Gaun; Lee, Yuan Tseh; Wang, Yi-Sheng; Lin, Sheng Hsien

    2014-08-15

    Although several reaction models have been proposed in the literature to explain matrix-assisted laser desorption/ionization (MALDI), further study is still necessary to explore the important ionization pathways that occur under the high-temperature environment of MALDI. 2,4,6-Trihydroxyacetophenone (THAP) is an ideal compound for evaluating the contribution of thermal energy to an initial reaction with minimum side reactions. Desorbed neutral THAP and ions were measured using a crossed-molecular beam machine and commercial MALDI-TOF instrument, respectively. A quantitative model incorporating an Arrhenius-type desorption rate derived from transition state theory was proposed. Reaction enthalpy was calculated using GAUSSIAN 03 software with dielectric effect. Additional evidence of thermal-induced proton disproportionation was given by the indirect ionization of THAP embedded in excess fullerene molecules excited by a 450 nm laser. The quantitative model predicted that proton disproportionation of THAP would be achieved by thermal energy converted from a commonly used single UV laser photon. The dielectric effect reduced the reaction Gibbs free energy considerably even when the dielectric constant was reduced under high-temperature MALDI conditions. With minimum fitting parameters, observations of pure THAP and THAP mixed with fullerene both agreed with predictions. Proton disproportionation of solid THAP was energetically favorable with a single UV laser photon. The quantitative model revealed an important initial ionization pathway induced by the abrupt heating of matrix crystals. In the matrix crystals, the dielectric effect reduced reaction Gibbs free energy under typical MALDI conditions. The result suggested that thermal energy plays an important role in the initial ionization reaction of THAP. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Congo Red Stain Identifies Matrix Overproduction and Is an Indirect Measurement for c-di-GMP in Many Species of Bacteria.

    PubMed

    Jones, Christopher J; Wozniak, Daniel J

    2017-01-01

    Congo red is a diazo textile dye that has been used to visualize the production of amyloid fibers for nearly a century. Microbiological applications were later developed, especially in identifying strains that produce amyloid appendages called curli and overexpressing polysaccharides in the biofilm matrix. The second messenger cyclic diguanylate (c-di-GMP) regulates the production of biofilm matrix polysaccharides, and therefore Congo red staining of samples can be utilized as an indirect measurement of elevated c-di-GMP production in bacteria. Congo red allows the identification of strains producing high c-di-GMP in an inexpensive, quantitative, and high-throughput manner.

  5. Basal Ganglia Disorders Associated with Imbalances in the Striatal Striosome and Matrix Compartments

    PubMed Central

    Crittenden, Jill R.; Graybiel, Ann M.

    2011-01-01

    The striatum is composed principally of GABAergic, medium spiny striatal projection neurons (MSNs) that can be categorized based on their gene expression, electrophysiological profiles, and input–output circuits. Major subdivisions of MSN populations include (1) those in ventromedial and dorsolateral striatal regions, (2) those giving rise to the direct and indirect pathways, and (3) those that lie in the striosome and matrix compartments. The first two classificatory schemes have enabled advances in understanding of how basal ganglia circuits contribute to disease. However, despite the large number of molecules that are differentially expressed in the striosomes or the extra-striosomal matrix, and the evidence that these compartments have different input–output connections, our understanding of how this compartmentalization contributes to striatal function is still not clear. A broad view is that the matrix contains the direct and indirect pathway MSNs that form parts of sensorimotor and associative circuits, whereas striosomes contain MSNs that receive input from parts of limbic cortex and project directly or indirectly to the dopamine-containing neurons of the substantia nigra, pars compacta. Striosomes are widely distributed within the striatum and are thought to exert global, as well as local, influences on striatal processing by exchanging information with the surrounding matrix, including through interneurons that send processes into both compartments. It has been suggested that striosomes exert and maintain limbic control over behaviors driven by surrounding sensorimotor and associative parts of the striatal matrix. Consistent with this possibility, imbalances between striosome and matrix functions have been reported in relation to neurological disorders, including Huntington’s disease, L-DOPA-induced dyskinesias, dystonia, and drug addiction. Here, we consider how signaling imbalances between the striosomes and matrix might relate to symptomatology in these disorders. PMID:21941467

  6. Disturbance, neutral theory, and patterns of beta diversity in soil communities.

    PubMed

    Maaß, Stefanie; Migliorini, Massimo; Rillig, Matthias C; Caruso, Tancredi

    2014-12-01

    Beta diversity describes how local communities within an area or region differ in species composition/abundance. There have been attempts to use changes in beta diversity as a biotic indicator of disturbance, but lack of theory and methodological caveats have hampered progress. We here propose that the neutral theory of biodiversity plus the definition of beta diversity as the total variance of a community matrix provide a suitable, novel, starting point for ecological applications. Observed levels of beta diversity (BD) can be compared to neutral predictions with three possible outcomes: Observed BD equals neutral prediction or is larger (divergence) or smaller (convergence) than the neutral prediction. Disturbance might lead to either divergence or convergence, depending on type and strength. We here apply these ideas to datasets collected on oribatid mites (a key, very diverse soil taxon) under several regimes of disturbances. When disturbance is expected to increase the heterogeneity of soil spatial properties or the sampling strategy encompassed a range of diverging environmental conditions, we observed diverging assemblages. On the contrary, we observed patterns consistent with neutrality when disturbance could determine homogenization of soil properties in space or the sampling strategy encompassed fairly homogeneous areas. With our method, spatial and temporal changes in beta diversity can be directly and easily monitored to detect significant changes in community dynamics, although the method itself cannot inform on underlying mechanisms. However, human-driven disturbances and the spatial scales at which they operate are usually known. In this case, our approach allows the formulation of testable predictions in terms of expected changes in beta diversity, thereby offering a promising monitoring tool.

  7. Higgs boson mass corrections in the μ ν SSM with effective potential methods

    NASA Astrophysics Data System (ADS)

    Zhang, Hai-Bin; Feng, Tai-Fu; Yang, Xiu-Yi; Zhao, Shu-Min; Ning, Guo-Zhu

    2017-04-01

    To solve the μ problem of the MSSM, the μ from ν supersymmetric standard model (μ ν SSM ) introduces three singlet right-handed neutrino superfields ν^ic, which lead to the mixing of the neutral components of the Higgs doublets with the sneutrinos, producing a relatively large C P -even neutral scalar mass matrix. In this work, we analytically diagonalize the C P -even neutral scalar mass matrix and analyze in detail how the mixing impacts the lightest Higgs boson mass. We also give an approximate expression for the lightest Higgs boson mass. Simultaneously, we consider the radiative corrections to the Higgs boson masses with effective potential methods.

  8. Loop-Mediated Isothermal Amplification for Laboratory Confirmation of Buruli Ulcer Disease—Towards a Point-of-Care Test

    PubMed Central

    Beissner, Marcus; Phillips, Richard Odame; Battke, Florian; Bauer, Malkin; Badziklou, Kossi; Sarfo, Fred Stephen; Maman, Issaka; Rhomberg, Agata; Piten, Ebekalisai; Frimpong, Michael; Huber, Kristina Lydia; Symank, Dominik; Jansson, Moritz; Wiedemann, Franz Xaver; Banla Kere, Abiba; Herbinger, Karl-Heinz; Löscher, Thomas; Bretzel, Gisela

    2015-01-01

    Background As the major burden of Buruli ulcer disease (BUD) occurs in remote rural areas, development of point-of-care (POC) tests is considered a research priority to bring diagnostic services closer to the patients. Loop-mediated isothermal amplification (LAMP), a simple, robust and cost-effective technology, has been selected as a promising POC test candidate. Three BUD-specific LAMP assays are available to date, but various technical challenges still hamper decentralized application. To overcome the requirement of cold-chains for transport and storage of reagents, the aim of this study was to establish a dry-reagent-based LAMP assay (DRB-LAMP) employing lyophilized reagents. Methodology/Principal Findings Following the design of an IS2404 based conventional LAMP (cLAMP) assay suitable to apply lyophilized reagents, a lyophylization protocol for the DRB-LAMP format was developed. Clinical performance of cLAMP was validated through testing of 140 clinical samples from 91 suspected BUD cases by routine assays, i.e. IS2404 dry-reagent-based (DRB) PCR, conventional IS2404 PCR (cPCR), IS2404 qPCR, compared to cLAMP. Whereas qPCR rendered an additional 10% of confirmed cases and samples respectively, case confirmation and positivity rates of DRB-PCR or cPCR (64.84% and 56.43%; 100% concordant results in both assays) and cLAMP (62.64% and 52.86%) were comparable and there was no significant difference between the sensitivity of the assays (DRB PCR and cPCR, 86.76%; cLAMP, 83.82%). Likewise, sensitivity of cLAMP (95.83%) and DRB-LAMP (91.67%) were comparable as determined on a set of 24 samples tested positive in all routine assays. Conclusions/Significance Both LAMP formats constitute equivalent alternatives to conventional PCR techniques. Provided the envisaged availability of field friendly DNA extraction formats, both assays are suitable for decentralized laboratory confirmation of BUD, whereby DRB-LAMP scores with the additional advantage of not requiring cold-chains. As validation of the assays was conducted in a third-level laboratory environment, field based evaluation trials are necessary to determine the clinical performance at peripheral health care level. PMID:26566026

  9. Anatomic partial nephrectomy: technique evolution.

    PubMed

    Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S

    2015-03-01

    Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.

  10. Novel screening techniques for ion channel targeting drugs

    PubMed Central

    Obergrussberger, Alison; Stölzle-Feix, Sonja; Becker, Nadine; Brüggemann, Andrea; Fertig, Niels; Möller, Clemens

    2015-01-01

    Ion channels are integral membrane proteins that regulate the flux of ions across the cell membrane. They are involved in nearly all physiological processes, and malfunction of ion channels has been linked to many diseases. Until recently, high-throughput screening of ion channels was limited to indirect, e.g. fluorescence-based, readout technologies. In the past years, direct label-free biophysical readout technologies by means of electrophysiology have been developed. Planar patch-clamp electrophysiology provides a direct functional label-free readout of ion channel function in medium to high throughput. Further electrophysiology features, including temperature control and higher-throughput instruments, are continually being developed. Electrophysiological screening in a 384-well format has recently become possible. Advances in chip and microfluidic design, as well as in cell preparation and handling, have allowed challenging cell types to be studied by automated patch clamp. Assays measuring action potentials in stem cell-derived cardiomyocytes, relevant for cardiac safety screening, and neuronal cells, as well as a large number of different ion channels, including fast ligand-gated ion channels, have successfully been established by automated patch clamp. Impedance and multi-electrode array measurements are particularly suitable for studying cardiomyocytes and neuronal cells within their physiological network, and to address more complex physiological questions. This article discusses recent advances in electrophysiological technologies available for screening ion channel function and regulation. PMID:26556400

  11. Novel screening techniques for ion channel targeting drugs.

    PubMed

    Obergrussberger, Alison; Stölzle-Feix, Sonja; Becker, Nadine; Brüggemann, Andrea; Fertig, Niels; Möller, Clemens

    2015-01-01

    Ion channels are integral membrane proteins that regulate the flux of ions across the cell membrane. They are involved in nearly all physiological processes, and malfunction of ion channels has been linked to many diseases. Until recently, high-throughput screening of ion channels was limited to indirect, e.g. fluorescence-based, readout technologies. In the past years, direct label-free biophysical readout technologies by means of electrophysiology have been developed. Planar patch-clamp electrophysiology provides a direct functional label-free readout of ion channel function in medium to high throughput. Further electrophysiology features, including temperature control and higher-throughput instruments, are continually being developed. Electrophysiological screening in a 384-well format has recently become possible. Advances in chip and microfluidic design, as well as in cell preparation and handling, have allowed challenging cell types to be studied by automated patch clamp. Assays measuring action potentials in stem cell-derived cardiomyocytes, relevant for cardiac safety screening, and neuronal cells, as well as a large number of different ion channels, including fast ligand-gated ion channels, have successfully been established by automated patch clamp. Impedance and multi-electrode array measurements are particularly suitable for studying cardiomyocytes and neuronal cells within their physiological network, and to address more complex physiological questions. This article discusses recent advances in electrophysiological technologies available for screening ion channel function and regulation.

  12. Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model

    DTIC Science & Technology

    2013-07-01

    fit at anatomic pressure points needed in hemorrhage control. The CRoC was placed on trauma manikins at the U.S. Army Med- ical Department Center and...simulant was pumped to quantify device effective- ness in testing. Points of application included proximal pressure point control of popliteal...a casualty’s wound from the point of injury on the battlefield to the emergency department has been impractical; so a device was made to replace the

  13. Dirac R -matrix calculations for the electron-impact excitation of neutral tungsten providing noninvasive diagnostics for magnetic confinement fusion

    NASA Astrophysics Data System (ADS)

    Smyth, R. T.; Ballance, C. P.; Ramsbottom, C. A.; Johnson, C. A.; Ennis, D. A.; Loch, S. D.

    2018-05-01

    Neutral tungsten is the primary candidate as a wall material in the divertor region of the International Thermonuclear Experimental Reactor (ITER). The efficient operation of ITER depends heavily on precise atomic physics calculations for the determination of reliable erosion diagnostics, helping to characterize the influx of tungsten impurities into the core plasma. The following paper presents detailed calculations of the atomic structure of neutral tungsten using the multiconfigurational Dirac-Fock method, drawing comparisons with experimental measurements where available, and includes a critical assessment of existing atomic structure data. We investigate the electron-impact excitation of neutral tungsten using the Dirac R -matrix method, and by employing collisional-radiative models, we benchmark our results with recent Compact Toroidal Hybrid measurements. The resulting comparisons highlight alternative diagnostic lines to the widely used 400.88-nm line.

  14. Histology and surface ultrastructure during early healing after gingival augmentation with a three-dimensional collagen matrix: A report of six cases.

    PubMed

    Rusu, Darian; Stratul, Stefan-Ioan; Festila, Dana; Surlin, Petra; Kasaj, Adrian; Baderca, Flavia; Boariu, Marius; Jentsch, Holger; Locovei, Cosmin; Calenic, Bogdan

    2017-01-01

    The objective of the present case series is to describe the histology and surface ultrastructure of augmented keratinized gingival mucosa in humans during the early healing phase after surgical placement of a xenogeneic collagen matrix. Six patients underwent surgical augmentation of keratinized tissue by placement of a three-dimensional (3D) xenogeneic collagen matrix. Full-depth mucosal biopsies including original attached gingiva, augmented gingiva, and the separation zone were performed at baseline and at postoperative days 7 and 14. The specimens were stained with hematoxylin-eosin, Masson-trichrome, picrosirius red, and Papanicolaou's trichrome. Low-vacuum scanning electron microscopy (SEM) surface analysis was correlated with histology. The separation zone was clearly visible upon histologic and SEM examination at 7 days. The portions of augmented mucosa consisted of well-structured, immature gingival tissue with characteristics of per secundam healing underlying a completely detached amorphous collagenous membrane-like structure of approximately 100 μm thick. At 14 days, histologic and ultrastructural examinations showed an almost complete maturation process. There were no detectable remnants of the collagen matrix within the newly formed tissues at either time point. Within their limits the results suggest that the 3D collagen matrix appears to play an indirect role during the early phase of wound healing by protecting the newly formed underlying tissue and guiding the epithelialization process.

  15. Seroprevalence of bovine viral diarrhea virus neutralizing antibodies in finisher hogs in Ontario swine herds and targeted diagnostic testing of 2 suspect herds

    PubMed Central

    O’Sullivan, Terri; Friendship, Robert; Carman, Susy; Pearl, David L.; McEwen, Beverly; Dewey, Catherine

    2011-01-01

    A pilot study was initiated to determine the seroprevalence of bovine viral diarrhea virus (BVDV) neutralizing antibodies in finisher hogs in Ontario swine herds, including 2 swine herds with clinical syndromes suspicious of BVDV. No herds were positive for BVDV antibodies by virus neutralization. The 2 swine herds with clinical disease suggestive of pestivirus infection were also negative for antibodies to BVDV in indirect fluorescent antibody assays. Prevalence of BVDV in Ontario swine farms is negligible. PMID:22654141

  16. Chemical Reactions Triggered Using Electrons Photodetached from "Clean" Distributions of Anions Deposited in Cryogenic Matrices via Counterion Codeposition.

    PubMed

    Ludwig, Ryan M; Moore, David T

    2014-09-04

    Application of matrix isolation spectroscopy to ionic species is typically complicated by the presence of neutral contaminants during matrix deposition. Herein we demonstrate that simultaneous deposition of balanced currents of counterions with mass-selected ions of interest generates "clean" distributions of matrix-isolated metal carbonyl anions, where the only bands appearing in the CO-stretching region of the vibrational spectrum arise from ions. (Neutrals are initially absent.) Photodetachment by mild irradiation with visible light leads to complete conversion of the anions into their corresponding neutral species. The photodetached electrons, in turn, initiate covalent chemistry, inducing C-C bond formation following electron-capture by CO van der Waals dimers to produce trans-OCCO(-). The initial clean distribution of ions enables clear connections to be drawn between the spectral changes occurring at each experimental step, thus demonstrating the potential of the counterion codeposition technique to facilitate detailed studies of chemistry involving ions and electron transfer in cryogenic matrices.

  17. A study of the vibrational energies of two coupled beams by finite element and green function (receptance) methods

    NASA Astrophysics Data System (ADS)

    Shankar, K.; Keane, A. J.

    1995-04-01

    The behaviour of two hinged-hinged beams, point coupled by springs (translational, rotary and a combination of both) with weak to strong coupling is studied from the point of view of vibrational energies, input power and power transferred through the coupling. Two configurations are studied: in the first case the beams are placed parallel to each other and only the transverse, Euler-Bernoulli modes are considered; the second configuration is more complicated with the beams placed perpendicular to each other, executing axial as well as transverse vibrations. These models are studied by using a finite element analysis (FEA) package and, alternatively, via the modally derived Green functions of the uncoupled subsystems. In both cases the beams are given proportional damping and one of the beams is driven by a point harmonic force. The effects of coupling stiffness and modal summation bandwidth are studied. It is shown that there is good agreement between the FEA and the Green function approach over a range of coupling strengths, but that at higher strengths the number of uncoupled modes used significantly affects the accuracy of the Green function method used here. The beams in the second configuration are then further studied from the point of view of SEA coupling loss factors. The frequency averaged coupling loss factors are calculated for weak and strong coupling, first by using a power injection method, where the power balance equations are formed on the assumption of only direct coupling loss factors. Then, the entire matrix of direct and indirect coupling loss factors is derived by using a deterministic modal approach. These are compared and the indirect coupling loss factors are found to be significant in magnitude in respect to the direct coupling loss factors. Several cases are studied in which the coupling powers and energy levels are predicted by using only the direct coupling loss factors and compared with the exact results obtained by using both direct and indirect factors. These agree only under certain conditions for weak coupling and show rather poorer agreement in the case of strong coupling. This behaviour demonstrates the importance of taking into account indirect coupling loss factors in SEA models having several subsystems.

  18. Critical stresses for extension of filament-bridged matrix cracks in ceramic-matrix composites: An assessment with a model composite with tailored interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Danchaivijit, S.; Shetty, D.K.; Eldridge, J.

    Matrix cracking was studied in a model unidirectional composite of SiC filaments in an epoxy-bonded alumina matrix. The residual clamping stress on the filaments due to the shrinkage of the epoxy was moderated with the addition of the alumina filler, and the filament surface was coated with a releasing agent to produce unbonded frictional interfaces. Uniaxial tension specimens with controlled through-cracks with bridging filaments were fabricated by a two-step casting technique. Critical stresses for extension of the filament-bridged cracks of various lengths were measured in uniaxial tension using a high-sensitivity extensometer. The measured crack-length dependence of the critical stress wasmore » in good agreement with the prediction of a stress-intensity analysis that employed a new force-displacement law for the bridging filaments. The analysis required independent experimental evaluation of the matrix fracture toughness, the interfacial sliding friction stress, and the residual tension in the matrix. The matrix-cracking stress for the test specimens without the deliberately introduced cracks was significantly higher than the steady-state cracking stress measured for the long, filament-bridged cracks.« less

  19. Finite-time stability of neutral-type neural networks with random time-varying delays

    NASA Astrophysics Data System (ADS)

    Ali, M. Syed; Saravanan, S.; Zhu, Quanxin

    2017-11-01

    This paper is devoted to the finite-time stability analysis of neutral-type neural networks with random time-varying delays. The randomly time-varying delays are characterised by Bernoulli stochastic variable. This result can be extended to analysis and design for neutral-type neural networks with random time-varying delays. On the basis of this paper, we constructed suitable Lyapunov-Krasovskii functional together and established a set of sufficient linear matrix inequalities approach to guarantee the finite-time stability of the system concerned. By employing the Jensen's inequality, free-weighting matrix method and Wirtinger's double integral inequality, the proposed conditions are derived and two numerical examples are addressed for the effectiveness of the developed techniques.

  20. An indirect approach to the extensive calculation of relationship coefficients

    PubMed Central

    Colleau, Jean-Jacques

    2002-01-01

    A method was described for calculating population statistics on relationship coefficients without using corresponding individual data. It relied on the structure of the inverse of the numerator relationship matrix between individuals under investigation and ancestors. Computation times were observed on simulated populations and were compared to those incurred with a conventional direct approach. The indirect approach turned out to be very efficient for multiplying the relationship matrix corresponding to planned matings (full design) by any vector. Efficiency was generally still good or very good for calculating statistics on these simulated populations. An extreme implementation of the method is the calculation of inbreeding coefficients themselves. Relative performances of the indirect method were good except when many full-sibs during many generations existed in the population. PMID:12270102

  1. Effects of acute hyperinsulinaemia on total and high-molecular-weight adiponectin concentration in metabolically healthy but obese postmenopausal women: a Montreal-Ottawa New Emerging Team (MONET) study.

    PubMed

    Elisha, B; Karelis, A D; Imbeault, P; Rabasa-Lhoret, R

    2010-09-01

    The aim of this study was to determine the differences and changes in total and high-molecular-weight (HMW) adiponectin levels among metabolically healthy but obese (MHO) postmenopausal women in response to acute hyperinsulinaemia. In this cross-sectional study, 55 non-diabetic overweight and obese postmenopausal women underwent a hyperinsulinaemic-euglycaemic clamp test to evaluate insulin sensitivity. Subjects within the upper tertile of insulin sensitivity were described as 'MHO' (n=18), whereas those within the lowest tertile were considered 'at risk' (n=18). Plasma total and HMW adiponectin levels were measured by ELISA at 0 (baseline), 90, 160 and 180 min during the clamp. At baseline and at all time points during the clamp, MHO individuals had significantly higher total and HMW adiponectin levels than at-risk subjects (AUC: total adiponectin=2506 ± 1010 vs 1616 ± 830; HMW adiponectin=909 ± 307 vs 604 ± 349; P<0.05). In addition, a significant reduction in total adiponectin was observed at 160 min and 180 min in at-risk and MHO subjects, respectively, while HMW adiponectin significantly decreased at 160 min in at-risk subjects, and at 90 min as well as 160 min in MHO women. MHO postmenopausal women had higher levels of plasma total and HMW adiponectin than at-risk subjects at baseline and during the clamp. Furthermore, significant decreases in total and HMW adiponectin were observed at certain time points in both the MHO and at-risk subjects. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  2. Muscarinic receptor agonists stimulate matrix metalloproteinase 1-dependent invasion of human colon cancer cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raufman, Jean-Pierre, E-mail: jraufman@medicine.umaryland.edu; Cheng, Kunrong; Saxena, Neeraj

    2011-11-18

    Highlights: Black-Right-Pointing-Pointer Muscarinic receptor agonists stimulated robust human colon cancer cell invasion. Black-Right-Pointing-Pointer Anti-matrix metalloproteinase1 antibody pre-treatment blocks cell invasion. Black-Right-Pointing-Pointer Bile acids stimulate MMP1 expression, cell migration and MMP1-dependent invasion. -- Abstract: Mammalian matrix metalloproteinases (MMPs) which degrade extracellular matrix facilitate colon cancer cell invasion into the bloodstream and extra-colonic tissues; in particular, MMP1 expression correlates strongly with advanced colon cancer stage, hematogenous metastasis and poor prognosis. Likewise, muscarinic receptor signaling plays an important role in colon cancer; muscarinic receptors are over-expressed in colon cancer compared to normal colon epithelial cells. Muscarinic receptor activation stimulates proliferation, migration and invasionmore » of human colon cancer cells. In mouse intestinal neoplasia models genetic ablation of muscarinic receptors attenuates carcinogenesis. In the present work, we sought to link these observations by showing that MMP1 expression and activation plays a mechanistic role in muscarinic receptor agonist-induced colon cancer cell invasion. We show that acetylcholine, which robustly increases MMP1 expression, stimulates invasion of HT29 and H508 human colon cancer cells into human umbilical vein endothelial cell monolayers - this was abolished by pre-incubation with atropine, a non-selective muscarinic receptor inhibitor, and by pre-incubation with anti-MMP1 neutralizing antibody. Similar results were obtained using a Matrigel chamber assay and deoxycholyltaurine (DCT), an amidated dihydroxy bile acid associated with colon neoplasia in animal models and humans, and previously shown to interact functionally with muscarinic receptors. DCT treatment of human colon cancer cells resulted in time-dependent, 10-fold increased MMP1 expression, and DCT-induced cell invasion was also blocked by pre-treatment with anti-MMP1 antibody. This study contributes to understanding mechanisms underlying muscarinic receptor agonist-induced promotion of colon cancer and, more importantly, indicates that blocking MMP1 expression and activation has therapeutic promise to stop or retard colon cancer invasion and dissemination.« less

  3. SiC-Based Miniature High-Temperature Cantilever Anemometer

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S.; Fralick, Gustave; Saad, George J.

    2004-01-01

    The figure depicts a miniature cantilever-type anemometer that has been developed as a prototype of compact, relatively nonintrusive anemometers that can function at temperatures up to 600 C and that can be expected to be commercially mass-producible at low cost. The design of this anemometer, and especially the packaging aspect of the design, is intended to enable measurement of turbulence in the high-temperature, high-vibration environment of a turbine engine or in any similar environment. The main structural components of the anemometer include a single-crystal SiC cantilever and two polycrystalline SiC clamping plates, all made from chemical-vapor-deposited silicon carbide. Fabrication of these components from the same basic material eliminates thermal-expansion mismatch, which has introduced spurious thermomechanical stresses in cantilever-type anemometers of prior design. The clamping plates are heavily oxidized to improve electrical insulation at high temperature. A cavity that serves as a receptacle for the clamped end of the cantilever is etched into one end of one clamping plate. Trenches that collectively constitute a socket for a multipin electrical plug (for connection to external electronic circuitry) are etched into the opposite end of this clamping plate. Metal strips for electrical contact are deposited on one face of the other clamping plate. Piezoresistive single-crystal SiC thin-film strain gauges are etched in the n-type SiC epilayer in a Wheatstone-bridge configuration. Metal contact pads on the cantilever that extend into the clamping-receptacle area, are obtained by deposition and patterning using standard semiconductor photolithography and etching methods. The cantilever and the two clamping plates are assembled into a sandwich structure that is then clamped in a stainless-steel housing. The Wheatstone- bridge carrying SiC cantilever with the metal contact pads on the piezoresistors is slid into the receptacle in the bottom clamping plate. The top clamping plate is brought into contact with the bottom plate so that the narrow section of the metal strips on the top clamp plate aligns with the metal contact pads on the cantilever. When the parts are clamped together, the metal strips provide electrical connections between the Wheatstone-bridge contact points and the sides the trenches that constitute the socket for the multipin electrical plug. Hence, to connect the Wheatstone bridge to external circuitry for processing of the anemometer readout, one need only insert the plug in the socket. In operation, the cantilever end of the stainless-steel housing is mounted flush with an engine wall and the unclamped portion of the cantilever is exposed into the flow. The cantilever is deflected in direct proportion to the force induced by component of flow parallel to the engine wall and perpendicular to the broad exposed face of the cantilever. The maximum strain on the cantilever occurs at the clamped edge and is measured by the piezoresistors, which are located there. The corresponding changes in resistance manifest themselves in the output of the Wheatstone bridge.

  4. Design of a biomimetic self-healing superalloy composite

    NASA Astrophysics Data System (ADS)

    Files, Bradley Steven

    1997-10-01

    Use of systems engineering concepts to design technologically advanced materials has allowed ambitious goals of self-healing alloys to be realized. Shape memory alloy reinforcements are embedded in an alloy matrix to demonstrate concepts of stable crack growth and matrix crack closure. Computer methods are used to design thermodynamically compatible iron-based alloys using bio-inspired concepts of crack bridging and self-healing. Feasibility of crack closure and stable crack growth is shown in a prototype system with a Sn-Bi matrix and TiNi fibers. Design of Fe-Ni-Co-Ti-Al alloys using thermodynamic models to determine stabilities and phase equilibria allows for a methodical system designing compatible multicomponent alloys for composite systems. Final alloy computations for this project led to the alloy Fe-27.6Ni-18.2Co-4.1Ti-1.6Al as a compatible shape memory a with a 650sp°C 90 minute heat treatment leading to martensite and austenite start temperatures (Msbs and Asbs) near room temperature. Thin slices of this alloy were able to fully recover at least 5% strain upon unloading heating. Composites made from the designed shape memory alloy and a compatible Fe-based B2 matrix were used to test self-healing concepts in the superalloy system. Diffusion couple experiments verified thermodynamic compatibility between matrix and reinforcement alloys at the solution treatment temperature of 1100sp°C. Concepts of stable crack growth and crack bridging were demonstrated in the composite, leading to enhanced toughness of the brittle matrix. However, healing behavior in this system was limited by intergranular fracture of the reinforcement alloy. It is believed that use of rapidly solidified powders could eliminate intergranular fracture, leading to greatly enhanced properties of toughening and healing. Crack clamping and stable crack growth were achieved in a feasibility study using a Sn-Bi matrix reinforced with TiNi fibers. Tensile specimens with less than 1% fibers showed an ability upon heating to recover over 80% of the plastic deformation induced during a tensile test. Further straining proved that stable crack growth can be realized in this system due to crack bridging of the shape memory fibers. Macroscopic cracks were clamped shut after heating of the material above the TiNi reversion temperature.

  5. Analysis of the internal nuclear matrix. Oligomers of a 38 kD nucleolar polypeptide stabilized by disulfide bonds.

    PubMed

    Fields, A P; Kaufmann, S H; Shaper, J H

    1986-05-01

    When rat liver nuclei are treated with the sulfhydryl cross-linking reagent sodium tetrathionate (NaTT) prior to nuclease treatment and extraction with 1.6 M NaCl, residual nucleoli and an extensive non-chromatin intranuclear network remain associated with the nuclear envelope. Subsequent treatment of this structure with 1 M NaCl containing 20 mM dithiothreitol (DTT) solubilizes the intranuclear material, while the nuclear envelope remains structurally intact. We have isolated and partially characterized a major polypeptide of the disulfide-stabilized internal nuclear matrix. The polypeptide, which has an apparent molecular mass 38 kD and isoelectric point 5.3, has been localized to the nucleolus of rat liver nuclei by indirect immunofluorescence using a specific polyclonal chicken antiserum. Based on its molecular mass, isoelectric point, intracellular localization and amino acid composition, the 38 kD polypeptide appears to be analogous to the nucleolar phosphoprotein B23 described by Prestayko et al. (Biochemistry 13 (1974) 1945) [20]. Immunologically related polypeptides have likewise been localized to the nucleoli of both hamster and human tissue culture cell lines as well as the cellular slime mold Physarum polycephalum. By immunoblotting, a single 38 kD polypeptide is recognized by the antiserum in rat, mouse, hamster and human cell lines. The antiserum has been utilized to investigate the oligomeric structure of the 38 kD polypeptide and the nature of its association with the rat liver nuclear matrix. By introducing varying numbers of disulfide bonds, we have found that the 38 kD polypeptide becomes incorporated into the internal nuclear matrix in a two-step process. Soluble disulfide-bonded homodimers of the polypeptide are first formed and then are rendered salt-insoluble by more extensive disulfide cross-linking.

  6. Facile MALDI-MS analysis of neutral glycans in NaOH-doped matrixes: microwave-assisted deglycosylation and one-step purification with diamond nanoparticles.

    PubMed

    Tzeng, Yan-Kai; Chang, Cheng-Chun; Huang, Chien-Ning; Wu, Chih-Che; Han, Chau-Chung; Chang, Huan-Cheng

    2008-09-01

    A streamlined protocol has been developed to accelerate, simplify, and enhance matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) of neutral underivatized glycans released from glycoproteins. It involved microwave-assisted enzymatic digestion and release of glycans, followed by rapid removal of proteins and peptides with carboxylated/oxidized diamond nanoparticles, and finally treating the analytes with NaOH before mixing them with acidic matrix (such as 2,5-dihydroxybenzoic acid) to suppress the formation of both peptide and potassiated oligosaccharide ions in MS analysis. The advantages of this protocol were demonstrated with MALDI-TOF-MS of N-linked glycans released from ovalbumin and ribonuclease B.

  7. MP-4 Contributes to Snake Venom Neutralization by Mucuna pruriens Seeds through an Indirect Antibody-mediated Mechanism*

    PubMed Central

    Kumar, Ashish; Gupta, Chitra; Salunke, Dinakar M.

    2016-01-01

    Mortality due to snakebite is a serious public health problem, and available therapeutics are known to induce debilitating side effects. Traditional medicine suggests that seeds of Mucuna pruriens can provide protection against the effects of snakebite. Our aim is to identify the protein(s) that may be important for snake venom neutralization and elucidate its mechanism of action. To this end, we have identified and purified a protein from M. pruriens, which we have named MP-4. The full-length polypeptide sequence of MP-4 was obtained through N-terminal sequencing of peptide fragments. Sequence analysis suggested that the protein may belong to the Kunitz-type protease inhibitor family and therefore may potentially neutralize the proteases present in snake venom. Using various structural and biochemical tools coupled with in vivo assays, we are able to show that MP-4 does not afford direct protection against snake venom because it is actually a poor inhibitor of serine proteases. Further experiments showed that antibodies generated against MP-4 cross-react with the whole venom and provide protection to mice against Echis carinatus snake venom. This study shows that the MP-4 contributes significantly to the snake venom neutralization activity of M. pruriens seeds through an indirect antibody-mediated mechanism. PMID:26987900

  8. Comparison of a neutralization enzyme immunoassay and an enzyme-linked immunosorbent assay for evaluation of immune status of children vaccinated for mumps.

    PubMed Central

    Harmsen, T; Jongerius, M C; van der Zwan, C W; Plantinga, A D; Kraaijeveld, C A; Berbers, G A

    1992-01-01

    A 50% neutralization enzyme immunoassay (N50-EIA) was compared with an indirect enzyme-linked immunosorbent assay (ELISA) for determining mumps virus antibodies in three consecutive serum samples from 138 children vaccinated with a live mumps vaccine at the age (in years) of 1.5. By the N50-EIA, most (132 of 138) preserum samples did not show neutralizing activity. Eight to 12 weeks after vaccination, 17 of the children were still negative, but only 7 remained so after 2.5 years, resulting in a seroconversion rate of 125 of 132 (95%). Over the same period, the neutralization geometric mean titer rose from 3.6 to 9.9. By an indirect ELISA, 128 of 138 preserum samples were found negative. The early and late postvaccination sera of 8 children were ELISA negative, resulting in a seroconversion rate of 120 of 128 (94%). Only two children remained seronegative by both methods. Seven of the late postvaccination serum samples yielded noncorresponding results, reflecting 95% correlation between both methods. Due to cross-reactivity with parainfluenza viruses, the ELISA proved to be less specific, but on the other hand, it showed a greater sensitivity than the N50-EIA. PMID:1500523

  9. Characterization of active hair-bundle motility by a mechanical-load clamp

    NASA Astrophysics Data System (ADS)

    Salvi, Joshua D.; Maoiléidigh, Dáibhid Ó.; Fabella, Brian A.; Tobin, Mélanie; Hudspeth, A. J.

    2015-12-01

    Active hair-bundle motility endows hair cells with several traits that augment auditory stimuli. The activity of a hair bundle might be controlled by adjusting its mechanical properties. Indeed, the mechanical properties of bundles vary between different organisms and along the tonotopic axis of a single auditory organ. Motivated by these biological differences and a dynamical model of hair-bundle motility, we explore how adjusting the mass, drag, stiffness, and offset force applied to a bundle control its dynamics and response to external perturbations. Utilizing a mechanical-load clamp, we systematically mapped the two-dimensional state diagram of a hair bundle. The clamp system used a real-time processor to tightly control each of the virtual mechanical elements. Increasing the stiffness of a hair bundle advances its operating point from a spontaneously oscillating regime into a quiescent regime. As predicted by a dynamical model of hair-bundle mechanics, this boundary constitutes a Hopf bifurcation.

  10. Stress-Strain Properties of SIFCON in Uniaxial Compression and Tension

    DTIC Science & Technology

    1988-08-01

    direction act as contacting beams whereas fibers aligned parallel to the loading direction act as individual columns . The combination of fiber-to-fiber...applicable to the study of SIFCON. These include such topics as the influence of strain rate on composite behavior, cyclic loading response, fiber-to-matrix...the specimen are shown in Figure 17. The grips consisted of self-clamping steel plates and a universal joint connection to the loading machine which

  11. Experimental and Numerical Analysis of Axially Compressed Circular Cylindrical Fiber-Reinforced Panels with Various Boundary Conditions.

    DTIC Science & Technology

    1981-10-01

    Numerical predictions used in the compari- sons were obtained from the energy -based, finite-difference computer proqram CLAPP. Test specimens were clamped...edges V LONGITUDINAL STIFFENERS 45 I. Introduction 45 2. Stiffener Strain Energy 46 3. Stiffener Energy in Matrix Form 47 4. Displacement Continuity 49...that theoretical bifurcation loads predicted by the energy method represent upper bounds to the classical bifurcation loads associated with the test

  12. Configuration and Calibration of High Temperature Furnaces for Testing Ceramic Matrix Composites

    DTIC Science & Technology

    2014-10-01

    Actual Furnace Cavity Stainless Steel Mesh Cage For Electrical Connections (both sides) High Temperature Power Lead Clamp Furnace Control TC’s Power... tests generate the basic properties such as modulus (E), ultimate tensile strength (UTS), proportional limit (PL), strain at failure (f), as well as...stress- strain behavior. Each material was tested at room temperature, at the maximum use temperature for the CMC system (as determined by the CMC

  13. Stress transfer around a broken fiber in unidirectional fiber-reinforced composites considering matrix damage evolution and interface slipping

    NASA Astrophysics Data System (ADS)

    Yang, Zhong; Zhang, BoMing; Zhao, Lin; Sun, XinYang

    2011-02-01

    A shear-lag model is applied to study the stress transfer around a broken fiber within unidirectional fiber-reinforced composites (FRC) subjected to uniaxial tensile loading along the fiber direction. The matrix damage and interfacial debonding, which are the main failure modes, are considered in the model. The maximum stress criterion with the linear damage evolution theory is used for the matrix. The slipping friction stress is considered in the interfacial debonding region using Coulomb friction theory, in which interfacial clamping stress comes from radial residual stress and mismatch of Poisson's ratios of constituents (fiber and matrix). The stress distributions in the fiber and matrix are obtained by the shear-lag theory added with boundary conditions, which includes force continuity and displacement compatibility constraints in the broken and neighboring intact fibers. The result gives axial stress distribution in fibers and shear stress in the interface and compares the theory reasonably well with the measurement by a polarized light microscope. The relation curves between damage, debonding and ineffective region lengths with external strain loading are obtained.

  14. Modulation of dayside on and neutral distributions at Venus Evidence of direct and indirect solar energy inputs

    NASA Technical Reports Server (NTRS)

    Taylor, H. A., Jr.; Mayr, H. G.; Grebowsky, J. M.; Niemann, H. B.; Hartle, R. E.; Cloutier, P. A.; Barnes, A.; Daniell, R. E., Jr.

    1982-01-01

    The details of solar variability and its coupled effects on the Venusian dayside are examined for evidence of short-term perturbations and associated energy inputs. Ion and neutral measurements obtained from the Orbiter Ion Mass Spectrometer and Orbital Neutral mass Spectrometer are used to show that the dayside concentrations of CO2(+) and the neutral gas temperature are smoothly modulated with a 28-day cycle reasonably matching that of the solar F(10.7) and EUV fluxes. Earlier measurements show less pronounced and more irregular modulations and more conspicuous short-term day-to-day fluctuations in the ions and neutrals, as well as relatively large enhancements in the solar wind, which appear consistent with differences in solar coronal behavior during the two periods. It is suggested that the solar wind variations cause fluctuations in joule heating, producing the observed short-term ion and neutral variations.

  15. [Sorption properties of various polysaccharide matrixes to Lactobacillus plantarum 8RA-3 bacteria].

    PubMed

    Bondarenko, V M; Larionov, I V; Rybal'chenko, O V; Potokin, I L; Ryzhankova, A V

    2011-01-01

    Study of sorption properties of various spherical polysaccharide matrixes designated as Spherocell to probiotic Lactobacillus plantarum 8RA-3 bacteria. Industrial strain of L. plantarum 8PA-3 was used. The process of immobilization of lactobacilli on 3 variants of spherical sorbents was studied. The first sorbent - neutral, composed of nonpolar cellulose matrix with ("0") charge, the second--DEAE obtained by modification of cellulose by diethylaminoethyl groups with positive ("+") charge and the third--CM (carboxymethyl) with negative ("-") charge. Cellulose matrixes were designated by us by the term Spherocell. Immobilization of bacterial cells on Spherocell was performed by addition of suspension containing 1.0 x 10(9) CFU/ml. The effect of bacterial immobilization was evaluated by CFU/ ml titration and by electron microscopy. The dependence on matrix charge of adsorption immobilization on sorbent granules of lactobacilli cells was shown. At certain equal parameters (granule size, surface characteristics, charge value) the positively charged matrix sorbed 3-10 times more cells than neutral and 20-25 times more than negatively charged matrix. Each 100-180 microm Spherocell DEAE particle could sorb more than 1000 viable bacterial cells. Positively charged polysaccharide matrix Spherocell DEAE obtained by modification of cellulose by diethylaminoethyl groups is promising for creation of immobilized probiotic preparations.

  16. Viscoelastic Properties of Advanced Polymer Composites for Ballistic Protective Applications

    DTIC Science & Technology

    1994-09-01

    ofthe Damaged Sample 78 Figure 69: Fracture Surface of Damage Area Near the Point of Penetration 79 Figure 70. Closer View ofthe Damaged Area...LIST OF TABLES Table 1. Basic Mechanical Properties of the Materials 6 Table 2. Initial DMA Test Results 23 Table 3. Flexural Three Point Bend... point bend testing was conducted using an Instron 1127 Universal Tester to verify the DMA test method and specimen clamping configuration. Interfacial

  17. Automated Patch-Clamp Methods for the hERG Cardiac Potassium Channel.

    PubMed

    Houtmann, Sylvie; Schombert, Brigitte; Sanson, Camille; Partiseti, Michel; Bohme, G Andrees

    2017-01-01

    The human Ether-a-go-go Related Gene (hERG) product has been identified as a central ion channel underlying both familial forms of elongated QT interval on the electrocardiogram and drug-induced elongation of the same QT segment. Indeed, reduced function of this potassium channel involved in the repolarization of the cardiac action potential can produce a type of life-threatening cardiac ventricular arrhythmias called Torsades de Pointes (TdP). Therefore, hERG inhibitory activity of newly synthetized molecules is a relevant structure-activity metric for compound prioritization and optimization in medicinal chemistry phases of drug discovery. Electrophysiology remains the gold standard for the functional assessment of ion channel pharmacology. The recent years have witnessed automatization and parallelization of the manual patch-clamp technique, allowing higher throughput screening on recombinant hERG channels. However, the multi-well plate format of automatized patch-clamp does not allow visual detection of potential micro-precipitation of poorly soluble compounds. In this chapter we describe bench procedures for the culture and preparation of hERG-expressing CHO cells for recording on an automated patch-clamp workstation. We also show that the sensitivity of the assay can be improved by adding a surfactant to the extracellular medium.

  18. 40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...

  19. 40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...

  20. 40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...

  1. 40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...

  2. 40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...

  3. Properties of nanocomposite PP fibres

    NASA Astrophysics Data System (ADS)

    Smole, Majda S.; Stakne, Kristina; Svetec, Diana G.; Kleinschek, Karin S.; Ribitsch, Volker

    2005-06-01

    PP-based nanocomposite fibres were prepared by direct polymer melt intercalation. With the intention to determine the size and dispersion of nanoparticles in the polymer matrix, fibres were plasma etched and SEM observations were performed. The influence of nanofiller content and coupling agent on electrokinetic properties was studied. PP monofilament fibres exhibit hydrophobe character with negative zeta potential value. The zeta potential value of co-polymer PP fibre decreases with increasing PPAA content and the isoelectric point IEP of co-polymer samples shifts towards acid region. Addition of modified montmorillonite due to the particles electropositive character, affects the reduction of zeta potential value and a slight shift of IEP towards neutral region is observed. Nano-particles content influences electrokinetic fibres properties, i.e. ZP value is changed, however IE point is not significantly changed by different concentrations of nanofiller. In addition to, mechanical properties of nanocomposite fibres were determined.

  4. Parallel multipoint recording of aligned and cultured neurons on corresponding Micro Channel Array toward on-chip cell analysis.

    PubMed

    Tonomura, W; Moriguchi, H; Jimbo, Y; Konishi, S

    2008-01-01

    This paper describes an advanced Micro Channel Array (MCA) so as to record neuronal network at multiple points simultaneously. Developed MCA is designed for neuronal network analysis which has been studied by co-authors using MEA (Micro Electrode Arrays) system. The MCA employs the principle of the extracellular recording. Presented MCA has the following advantages. First of all, the electrodes integrated around individual micro channels are electrically isolated for parallel multipoint recording. Sucking and clamping of cells through micro channels is expected to improve the cellular selectivity and S/N ratio. In this study, hippocampal neurons were cultured on the developed MCA. As a result, the spontaneous and evoked spike potential could be recorded by sucking and clamping the cells at multiple points. Herein, we describe the successful experimental results together with the design and fabrication of the advanced MCA toward on-chip analysis of neuronal network.

  5. Indirect iterative learning control for a discrete visual servo without a camera-robot model.

    PubMed

    Jiang, Ping; Bamforth, Leon C A; Feng, Zuren; Baruch, John E F; Chen, YangQuan

    2007-08-01

    This paper presents a discrete learning controller for vision-guided robot trajectory imitation with no prior knowledge of the camera-robot model. A teacher demonstrates a desired movement in front of a camera, and then, the robot is tasked to replay it by repetitive tracking. The imitation procedure is considered as a discrete tracking control problem in the image plane, with an unknown and time-varying image Jacobian matrix. Instead of updating the control signal directly, as is usually done in iterative learning control (ILC), a series of neural networks are used to approximate the unknown Jacobian matrix around every sample point in the demonstrated trajectory, and the time-varying weights of local neural networks are identified through repetitive tracking, i.e., indirect ILC. This makes repetitive segmented training possible, and a segmented training strategy is presented to retain the training trajectories solely within the effective region for neural network approximation. However, a singularity problem may occur if an unmodified neural-network-based Jacobian estimation is used to calculate the robot end-effector velocity. A new weight modification algorithm is proposed which ensures invertibility of the estimation, thus circumventing the problem. Stability is further discussed, and the relationship between the approximation capability of the neural network and the tracking accuracy is obtained. Simulations and experiments are carried out to illustrate the validity of the proposed controller for trajectory imitation of robot manipulators with unknown time-varying Jacobian matrices.

  6. Sub-diffusion and trapped dynamics of neutral and charged probes in DNA-protein coacervates

    NASA Astrophysics Data System (ADS)

    Arfin, Najmul; Yadav, Avinash Chand; Bohidar, H. B.

    2013-11-01

    The physical mechanism leading to the formation of large intermolecular DNA-protein complexes has been studied. Our study aims to explain the occurrence of fast coacervation dynamics at the charge neutralization point, followed by the appearance of smaller complexes and slower coacervation dynamics as the complex experiences overcharging. Furthermore, the electrostatic potential and probe mobility was investigated to mimic the transport of DNA / DNA-protein complex in a DNA-protein complex coacervate medium [N. Arfin and H. B. Bohidar, J. Phys. Chem. B 116, 13192 (2012)] by assigning neutral, negative, or positive charge to the probe particle. The mobility of the neutral probe was maximal at low matrix concentrations and showed random walk behavior, while its mobility ceased at the jamming concentration of c = 0.6, showing sub-diffusion and trapped dynamics. The positively charged probe showed sub-diffusive random walk followed by trapped dynamics, while the negatively charged probe showed trapping with occasional hopping dynamics at much lower concentrations. Sub-diffusion of the probe was observed in all cases under consideration, where the electrostatic interaction was used exclusively as the dominant force involved in the dynamics. For neutral and positive probes, the mean square displacement ⟨R2⟩ exhibits a scaling with time as ⟨R2⟩ ˜ tα, distinguishing random walk and trapped dynamics at α = 0.64 ± 0.04 at c = 0.12 and c = 0.6, respectively. In addition, the same scaling factors with the exponent β = 0.64 ± 0.04 can be used to distinguish random walk and trapped dynamics for the neutral and positive probes using the relation between the number of distinct sites visited by the probe, S(t), which follows the scaling, S(t) ˜ tβ/ln (t). Our results established the occurrence of a hierarchy of diffusion dynamics experienced by a probe in a dense medium that is either charged or neutral.

  7. The indirect fluorescent antibody technique as a method for detecting antibodies in aborted fetuses.

    PubMed Central

    Miller, R B; Wilkie, B N

    1979-01-01

    In this investigation the indirect fluorescent antibody technique was used to titrate antibodies in bovine sera to parainfluenza 3, infectious bovine rhinotracheitis virus and bovine viral diarrhea virus. These results were compared to those determined on the same samples by hemagglutination inhibition for parainfluenza 3 virus and serum neutralization for bovine virus diarrhea and infectious bovine rhinotracheitis virus. The results of the serological methods agreed closely. The indirect fluorescent antibody technique is a rapid and sensitive method for detecting antibodies and the procedure lends itself to use in diagnostic laboratories. In addition to the above viruses the presence or absence of antibodies to bovine coronavirus and bovine adenovirus 3 were determined by the indirect fluorescent antibody technique in thoracic fluids from 100 aborted fetuses and 50 nonaborted fetuses. Results on these samples were not compared to hemagglutination inhibition or serum neutralization as the condition of fluid samples from aborted fetuses renders interpretation of such tests unreliable. Antibodies to one or more viruses were detected in 30 of the 100 aborted fetuses and in seven of the 50 nonaborted fetuses. Antibodies to more than one agent were detected in eleven of the 100 aborted and in one of the 50 nonaborted fetuses. Reasons for this occurrence and application of the test in determination of causes of abortion are discussed. PMID:226243

  8. Controlled Neutralization of Anions in Cryogenic Matrices by Near-Threshold Photodetachment

    NASA Astrophysics Data System (ADS)

    Ludwig, Ryan M.; Moore, David T.

    2014-06-01

    Using matrix isolation FTIR, we have observed the formation of anionic copper carbonyl complexes [Cu(CO)n]- (n=1-3) following co-deposition of Cu- and counter-cations (Ar+ or Kr+) into argon matrices doped with CO. The infrared bands have been previously assigned in argon matrix studies employing laser ablation, however they were quite weak compared to the bands for the corresponding neutral species. In the current study, when the deposition is carried out in fully darkened conditions at 10 K with high CO concentrations (1-2%), only the bands for the anionic complexes are observed initially via FTIR. However, upon mild irradiation with broadband visible light, the anionic bands are rapidly depleted, with concomitant appearance of bands corresponding to neutral copper carbonyl complexes. This photo-triggered neutralization is attributed to photodetachment of electrons from the anions, which then "flow" through the solid argon matrix to recombine in the matrix with non-adjacent trapping sites. This mechanism is supported by the appearance of a new band near 1515 wn, assigned to the (CO)2- species in argon. The wavelength dependence of the photodetachment will be discussed in detail, although preliminary indications are that the thresholds for the copper carbonyls, which are normally in the infrared, are shifted into the visible region of the spectrum in argon matrices. This likely occurs because the conduction band of solid argon is known to lie about 1 eV above the vacuum level, and thus the electron must have at least this much energy in order to escape into the matrix and find a trapping site. Funding support from NSF CAREER Award CHE-0955637 is gratefully acknowledged Ryan M. Ludwig and David T. Moore, J. Chem. Phys. 139, 244202 (2013) Zhou, M.; Andrews, L., J. Chem. Phys. 111, 4548 (1999). Thompson, W.E.; Jacox, M.E.; J. Chem. Phys. 91, 735 (1991). Stanzel, J. et al.; Collect. Czech. Chem. Comm. 72, 1 (2007). Harbich, W. et al.; Phys. Rev. B. 76, 104306 (2007).

  9. Influence of molecular shape, conformability, net surface charge, and tissue interaction on transscleral macromolecular diffusion.

    PubMed

    Srikantha, Nishanthan; Mourad, Fatma; Suhling, Klaus; Elsaid, Naba; Levitt, James; Chung, Pei Hua; Somavarapu, Satyanarayana; Jackson, Timothy L

    2012-09-01

    The purpose of this study was to investigate the influence of molecular shape, conformability, net surface charge and tissue interaction on transscleral diffusion. Unfixed, porcine sclera was clamped in an Ussing chamber. Fluorophore-labelled neutral albumin, neutral dextran, or neutral ficoll were placed in one hemi-chamber and the rate of transscleral diffusion was measured over 24 h using a spectrophotometer. Experiments were repeated using dextrans and ficoll with positive or negative net surface charges. Fluorescence recovery after photobleaching (FRAP) was undertaken to compare transscleral diffusion with diffusion through a solution. All molecules were 70 kDa. With FRAP, the diffusion coefficient (D) of neutral molecules was highest for albumin, followed by ficoll, then dextran (p < 0.0001). Positive dextrans diffused fastest, followed by negative, then neutral dextrans (p = 0.0004). Neutral ficoll diffused the fastest, followed by positive then negative ficoll (p = 0.5865). For the neutral molecules, transscleral D was highest for albumin, followed by dextran, then ficoll (p < 0.0001). D was highest for negative ficoll, followed by neutral, then positive ficoll (p < 0.0001). By contrast, D was highest for positive dextran, followed by neutral, then negative dextran (p = 0.0021). In conclusion, diffusion in free solution does not predict transscleral diffusion and the molecular-tissue interaction is important. Molecular size, shape, and charge may all markedly influence transscleral diffusion, as may conformability to a lesser degree, but their effects may be diametrically opposed in different molecules, and their influence on diffusion is more complex than previously thought. Each variable cannot be considered in isolation, and the interplay of all these variables needs to be tested, when selecting or designing drugs for transscleral delivery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Addition of n-3 fatty acids to a 4-hour lipid infusion does not affect insulin sensitivity, insulin secretion, or markers of oxidative stress in subjects with type 2 diabetes mellitus.

    PubMed

    Mostad, Ingrid L; Bjerve, Kristian S; Basu, Samar; Sutton, Pauline; Frayn, Keith N; Grill, Valdemar

    2009-12-01

    Fatty acids (FA) can impair glucose metabolism to a varying degree depending on time of exposure and also of type of FA. Here we tested for acute effects of marine n-3 FA on insulin sensitivity, insulin secretion, energy metabolism, and oxidative stress. This was a randomized, double-blind, crossover study in 11 subjects with type 2 diabetes mellitus. A 4-hour lipid infusion (Intralipid [Fresenius Kabi, Halden, Norway], total of 384 mL) was compared with a similar lipid infusion partly replaced by Omegaven (Fresenius Kabi) that contributed a median of 0.1 g fish oil per kilogram body weight, amounting to 0.04 g/kg of marine n-3 FA. Insulin sensitivity was assessed by isoglycemic hyperinsulinemic clamps; insulin secretion (measured after the clamps), by C-peptide glucagon tests; and energy metabolism, by indirect calorimetry. Infusion of Omegaven increased the proportion of n-3 FA in plasma nonesterified fatty acids (NEFA) compared with Intralipid alone (20:5n-3: median, 1.5% [interquartile range, 0.6%] vs -0.2% [0.2%], P = .001; 22:6n-3: 0.8% [0.4%] vs -0.7% [0.2%], P = .001). However, glucose utilization was not affected; neither was insulin secretion or total energy production (P = .966, .210, and .423, respectively, for the differences between the lipid clamps). Omegaven tended to lower oxidation of fat (P = .062) compared with Intralipid only, correlating with the rise in individual n-3 NEFA (r = 0.627, P = .039). The effects of clamping on phospholipid FA composition, leptin, adiponectin, or F(2)-isoprostane concentrations were not affected by Omegaven. Enrichment of NEFA with n-3 FA during a 4-hour infusion of Intralipid failed to affect insulin sensitivity, insulin secretion, or markers of oxidative stress in subjects with type 2 diabetes mellitus.

  11. Elastin-derived peptides promote abdominal aortic aneurysm formation by modulating M1/M2 macrophage polarization1

    PubMed Central

    Dale, Matthew A; Xiong, Wanfen; Carson, Jeffrey S; Suh, Melissa K; Karpisek, Andrew D.; Meisinger, Trevor M.; Casale, George P.; Baxter, B. Timothy

    2016-01-01

    Abdominal aortic aneurysm (AAA) is a dynamic vascular disease characterized by inflammatory cell invasion and extracellular matrix (ECM) degradation. Damage to elastin in the ECM results in release of elastin-derived peptides (EDPs), which are chemotactic for inflammatory cells such as monocytes. Their effect on macrophage polarization is less well known. Pro-inflammatory M1 macrophages initially are recruited to sites of injury but, if their effects are prolonged, they can lead to chronic inflammation that prevents normal tissue repair. Conversely, anti-inflammatory M2 macrophages reduce inflammation and aid in wound healing. Thus, a proper M1/M2 ratio is vital for tissue homeostasis. AAA tissue reveals a high M1/M2 ratio where pro-inflammatory cells and their associated markers dominate. In the present study, in vitro treatment of bone marrow-derived macrophages with EDPs induced M1 macrophage polarization. By using C57Bl/6 mice, antibody-mediated neutralization of EDPs reduced aortic dilation, matrix metalloproteinase activity, and pro-inflammatory cytokine expression at early and late time points after aneurysm induction. Furthermore, direct manipulation of the M1/M2 balance altered aortic dilation. Injection of M2 polarized macrophages reduced aortic dilation after aneurysm induction. EDPs promoted a pro-inflammatory environment in aortic tissue by inducing M1 polarization and neutralization of EDPs attenuated aortic dilation. The M1/M2 imbalance is vital to aneurysm formation. PMID:27183603

  12. Quantitative Assessment of Knee Progression Angle During Gait in Children With Cerebral Palsy.

    PubMed

    Davids, Jon R; Cung, Nina Q; Pomeroy, Robin; Schultz, Brooke; Torburn, Leslie; Kulkarni, Vedant A; Brown, Sean; Bagley, Anita M

    2018-04-01

    Abnormal hip rotation is a common deviation in children with cerebral palsy (CP). Clinicians typically assess hip rotation during gait by observing the direction that the patella points relative to the path of walking, which is referred to as the knee progression angle (KPA). Two kinematic methods for calculating the KPA are compared with each other. Video-based qualitative assessment of KPA is compared with the quantitative methods to determine reliability and validity. The KPA was calculated by both direct and indirect methods for 32 typically developing (TD) children and a convenience cohort of 43 children with hemiplegic type CP. An additional convenience cohort of 26 children with hemiplegic type CP was selected for qualitative assessment of KPA, performed by 3 experienced clinicians, using 3 categories (internal, >10 degrees; neutral, -10 to 10 degrees; and external, >-10 degrees). Root mean square (RMS) analysis comparing the direct and indirect KPAs was 1.14+0.43 degrees for TD children, and 1.75+1.54 degrees for the affected side of children with CP. The difference in RMS among the 2 groups was statistically, but not clinically, significant (P=0.019). Intraclass correlation coefficient revealed excellent agreement between the direct and indirect methods of KPA for TD and CP children (0.996 and 0.992, respectively; P<0.001).For the qualitative assessment of KPA there was complete agreement among all examiners for 17 of 26 cases (65%). Direct KPA matched for 49 of 78 observations (63%) and indirect KPA matched for 52 of 78 observations (67%). The RMS analysis of direct and indirect methods for KPA was statistically but not clinically significant, which supports the use of either method based upon availability. Video-based qualitative assessment of KPA showed moderate reliability and validity. The differences between observed and calculated KPA indicate the need for caution when relying on visual assessments for clinical interpretation, and demonstrate the value of adding KPA calculation to standard kinematic analysis. Level II-diagnostic test.

  13. MP-4 Contributes to Snake Venom Neutralization by Mucuna pruriens Seeds through an Indirect Antibody-mediated Mechanism.

    PubMed

    Kumar, Ashish; Gupta, Chitra; Nair, Deepak T; Salunke, Dinakar M

    2016-05-20

    Mortality due to snakebite is a serious public health problem, and available therapeutics are known to induce debilitating side effects. Traditional medicine suggests that seeds of Mucuna pruriens can provide protection against the effects of snakebite. Our aim is to identify the protein(s) that may be important for snake venom neutralization and elucidate its mechanism of action. To this end, we have identified and purified a protein from M. pruriens, which we have named MP-4. The full-length polypeptide sequence of MP-4 was obtained through N-terminal sequencing of peptide fragments. Sequence analysis suggested that the protein may belong to the Kunitz-type protease inhibitor family and therefore may potentially neutralize the proteases present in snake venom. Using various structural and biochemical tools coupled with in vivo assays, we are able to show that MP-4 does not afford direct protection against snake venom because it is actually a poor inhibitor of serine proteases. Further experiments showed that antibodies generated against MP-4 cross-react with the whole venom and provide protection to mice against Echis carinatus snake venom. This study shows that the MP-4 contributes significantly to the snake venom neutralization activity of M. pruriens seeds through an indirect antibody-mediated mechanism. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  14. Mechanism of opening a sliding clamp

    PubMed Central

    Douma, Lauren G.; Yu, Kevin K.; England, Jennifer K.

    2017-01-01

    Abstract Clamp loaders load ring-shaped sliding clamps onto DNA where the clamps serve as processivity factors for DNA polymerases. In the first stage of clamp loading, clamp loaders bind and stabilize clamps in an open conformation, and in the second stage, clamp loaders place the open clamps around DNA so that the clamps encircle DNA. Here, the mechanism of the initial clamp opening stage is investigated. Mutations were introduced into the Escherichia coli β-sliding clamp that destabilize the dimer interface to determine whether the formation of an open clamp loader–clamp complex is dependent on spontaneous clamp opening events. In other work, we showed that mutation of a positively charged Arg residue at the β-dimer interface and high NaCl concentrations destabilize the clamp, but neither facilitates the formation of an open clamp loader–clamp complex in experiments presented here. Clamp opening reactions could be fit to a minimal three-step ‘bind-open-lock’ model in which the clamp loader binds a closed clamp, the clamp opens, and subsequent conformational rearrangements ‘lock’ the clamp loader–clamp complex in a stable open conformation. Our results support a model in which the E. coli clamp loader actively opens the β-sliding clamp. PMID:28973453

  15. Which aortic clamp strategy is better to reduce postoperative stroke and death

    PubMed Central

    Chen, Liyu; Hua, Xiumeng; Song, Jiangping; Wang, Liqing

    2018-01-01

    Abstract Background: Stroke is severe complication of coronary artery bypass grafting (CABG) which may be associated with clamp strategy, there are 2 strategies to clamp aorta including single aortic clamp (SAC) and partial aortic clamp (PAC). It is controversial that which clamping strategy is better to reduce the postoperative stroke and death, so this study aims to investigate which is better for reducing postoperative stroke and death within 30 days. Methods: We collected 469 patients who had on-pump CABG in Fuwai Hospital during January 2014 to July 2015. The SAC group consisted of 265 patients while the PAC group included 204 patients. We compared the 2 group patient difference. At the same time, 12 studies were identified by systematic search. The odds ratio (OR) was used as effect index to compare SAC and PAC strategy by fix-effect modeling. We also tested heterogeneity and publication bias. The primary end point of study was occurrence of postoperative stroke within 30 days of operation, the second end point of study was the incidence of 30-day mortality. Results: The single center retrospective study showed that the patients in the SAC group were older than those in the PAC group (62.5 ± 8.1 vs 60.3 ± 8.0 years, P = .01). The proportions of peripheral vascular disease and hypertension of SAC were higher than PAC (71 (26.8%) versus 36 (17.6%), P = .02; 183 (69.1%) versus 115 (56.4%), P = .01, respectively). Besides, the number of vascular anastomosis was more in the SAC group (3.29 ± 0.74 versus 2.97 ± 0.974, P < .001). The linear-regression analysis suggested that the time of cardiopulmonary bypass of SAC was shorter than the PAC group (93.2 ± 22.4 vs.103.4 ± 26.8 minutes, P-regression < .001) and postoperative death within 30-days was similar (1 (0.4%) vs. 2 (1.0%), P-regression = .47). There was no stroke occurring in both the groups. And the meta-analysis suggested the postoperative stroke and death within 30-days were similar between SAC group and PAC group (OR: 0.78, 95% CI: 0.58–1.06; OR: 0.82, 95% CI: 0.61–1.10; respectively). Moreover, subgroup meta-analysis also had the same results. Conclusion: There was no significant difference between SAC and PAC clamping strategy on postoperative stroke and death within 30-days; however, SAC can reduce the usage time of cardiopulmonary bypass. PMID:29561451

  16. Atmospheric neutral points outside of the principal plane. [points of vanished skylight polarization

    NASA Technical Reports Server (NTRS)

    Fraser, R. S.

    1981-01-01

    It is noted that the positions in the sky where the skylight is unpolarized, that is, the neutral points, are in most cases located in the vertical plane through the sun (the principal plane). Points have been observed outside the principal plane (Soret, 1888) when the plane intersected a lake or sea. Here, the neutral points were located at an azimuth of about 15 deg from the sun and near the almucantar through the sun. In order to investigate the effects of water surface and aerosols in the neutral point positions, the positions are computed for models of the earth-atmosphere system that simulate the observational conditions. The computed and measured positions are found to agree well. While previous observations provided only qualitative information on the degree of polarization, it is noted that the computations provide details concerning the polarization parameters.

  17. Multiple scattered radiation emerging from continental haze layers. 1: Radiance, polarization, and neutral points

    NASA Technical Reports Server (NTRS)

    Kattawar, G. W.; Plass, G. N.; Hitzfelder, S. J.

    1975-01-01

    The complete radiation field is calculated for scattering layers of various optical thicknesses. Results obtained for Rayleigh and haze scattering are compared. Calculated radiances show differences as large as 23% compared to the approximate scalar theory of radiative transfer, while the same differences are approximately 0.1% for a continental haze phase function. The polarization of reflected and transmitted radiation is given for various optical thicknesses, solar zenith angles, and surface albedos. Two types of neutral points occur for aerosol phase functions. Rayleigh-like neutral points arise from zero polarization that occurs at scattering angles of 0 deg and 180 deg. For Rayleigh phase functions, the position of these points varies with the optical thickness of the scattering layer. Non-Rayleigh neutral points are associated with the zeros of polarization which occur between the end points of the single scattering curve, and are found over a wide range of azimuthal angles.

  18. Negative ion MALDI-TOF MS, ISD and PSD of neutral underivatized oligosaccharides without anionic dopant strategies, using 2,5-DHAP as a matrix.

    PubMed

    Jovanović, Marko; Peter-Katalinić, Jasna

    2016-02-01

    Oligosaccharides represent complex class of analytes for mass spectrometric analysis due to the high variety of structural isomers concerning glycosidic linkages and possible branching. A systematic study of the negative ion mode matrix-assisted laser desorption/ionization (MALDI) mass spectrometry of various neutral oligosaccharides under selection of an appropriate matrix, like 2,5-dihydroxyacetophenone (2,5-DHAP) is reported here, without commonly used anion dopant strategies. Nevertheless, we were able to generate relevant in-source decay (ISD) cross-ring fragment ions, typically obtained in the negative ion mode. Data observed indicate that the intrinsic property of the terminal non-reduced aldose is crucial for this behavior. A systematic study of the post source decay (PSD) of molecular, pseudomolecular and ISD cross-ring cleavage precursor ions is reported here. A direct comparison of the positive and negative ion mode MALDI MS1 and PSD behavior of neutral oligosaccharides could also be performed under the use of the same matrix preparation, because 2,5-DHAP is fully compatible with positive ion mode acquisition. We found that PSD spectra of deprotonated neutral oligosaccharides obtained in the negative ion mode are richer, because they contained both glycosidic and cross-ring fragment ions. However, we also found that cross-ring fragment ions are readily produced in the positive ion mode when potassiated precursor ions were selected. In addition, we show evidence that non-anionic dopants and specific instrumental parameters can also significantly influence the ISD fragmentation. Taken together, our results should increase our understanding of oligosaccharide behavior in the negative ion mode as well as increase our knowledge regarding many aspects of in-source MALDI chemistry. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Complexes of dipolar excitons in layered quasi-two-dimensional nanostructures

    NASA Astrophysics Data System (ADS)

    Bondarev, Igor V.; Vladimirova, Maria R.

    2018-04-01

    We discuss neutral and charged complexes (biexcitons and trions) formed by indirect excitons in layered quasi-two-dimensional semiconductor heterostructures. Indirect excitons—long-lived neutral Coulomb-bound pairs of electrons and holes of different layers—have been known for semiconductor coupled quantum wells and have recently been reported for van der Waals heterostructures such as double bilayer graphene and transition-metal dichalcogenides. Using the configuration space approach, we derive the analytical expressions for the trion and biexciton binding energies as a function of interlayer distance. The method captures essential kinematics of complex formation to reveal significant binding energies, up to a few tens of meV for typical interlayer distances ˜3 -5 Å , with the trion binding energy always being greater than that of the biexciton. Our results can contribute to the understanding of more complex many-body phenomena such as exciton Bose-Einstein condensation and Wigner-like electron-hole crystallization in layered semiconductor heterostructures.

  20. Healing rate and autoimmune safety of full-thickness wounds treated with fish skin acellular dermal matrix versus porcine small-intestine submucosa: a noninferiority study.

    PubMed

    Baldursson, Baldur Tumi; Kjartansson, Hilmar; Konrádsdóttir, Fífa; Gudnason, Palmar; Sigurjonsson, Gudmundur F; Lund, Sigrún Helga

    2015-03-01

    A novel product, the fish skin acellular dermal matrix (ADM) has recently been introduced into the family of biological materials for the treatment of wounds. Hitherto, these products have been produced from the organs of livestock. A noninferiority test was used to compare the effect of fish skin ADM against porcine small-intestine submucosa extracellular matrix in the healing of 162 full-thickness 4-mm wounds on the forearm of 81 volunteers. The fish skin product was noninferior at the primary end point, healing at 28 days. Furthermore, the wounds treated with fish skin acellular matrix healed significantly faster. These results might give the fish skin ADM an advantage because of its environmental neutrality when compared with livestock-derived products. The study results on these acute full-thickness wounds might apply for diabetic foot ulcers and other chronic full-thickness wounds, and the shorter healing time for the fish skin-treated group could influence treatment decisions. To test the autoimmune reactivity of the fish skin, the participants were tested with the following ELISA (enzyme-linked immunosorbent assay) tests: RF, ANA, ENA, anti ds-DNA, ANCA, anti-CCP, and anticollagen I and II. These showed no reactivity. The results demonstrate the claims of safety and efficacy of fish skin ADM for wound care. © The Author(s) 2015.

  1. Nanophosphor composite scintillator with a liquid matrix

    DOEpatents

    McKigney, Edward Allen; Burrell, Anthony Keiran; Bennett, Bryan L.; Cooke, David Wayne; Ott, Kevin Curtis; Bacrania, Minesh Kantilal; Del Sesto, Rico Emilio; Gilbertson, Robert David; Muenchausen, Ross Edward; McCleskey, Thomas Mark

    2010-03-16

    An improved nanophosphor scintillator liquid comprises nanophosphor particles in a liquid matrix. The nanophosphor particles are optionally surface modified with an organic ligand. The surface modified nanophosphor particle is essentially surface charge neutral, thereby preventing agglomeration of the nanophosphor particles during dispersion in a liquid scintillator matrix. The improved nanophosphor scintillator liquid may be used in any conventional liquid scintillator application, including in a radiation detector.

  2. Lipid-glass adhesion in giga-sealed patch-clamped membranes.

    PubMed

    Opsahl, L R; Webb, W W

    1994-01-01

    Adhesion between patch-clamped lipid membranes and glass micropipettes is measured by high contrast video imaging of the mechanical response to the application of suction pressure across the patch. The free patch of membrane reversibly alters both its contact angle and radius of curvature on pressure changes. The assumption that an adhesive force between the membrane and the pipette can sustain normal tension up to a maximum Ta at the edge of the free patch accounts for the observed mechanical responses. When the normal component of the pressure-induced membrane tension exceeds Ta membrane at the contact point between the free patch and the lipid-glass interface is pulled away from the pipette wall, resulting in a decreased radius of curvature for the patch and an increased contact angle. Measurements of the membrane radius of curvature as a function of the suction pressure and pipette radius determine line adhesion tensions Ta which range from 0.5 to 4.0 dyn/cm. Similar behavior of patch-clamped cell membranes implies similar adhesion mechanics.

  3. A Dynamic Clamp on Every Rig

    PubMed Central

    2017-01-01

    Abstract The dynamic clamp should be a standard part of every cellular electrophysiologist’s toolbox. That it is not, even 25 years after its introduction, comes down to three issues: money, the disruption that adding dynamic clamp to an existing electrophysiology rig entails, and the technical prowess required of experimenters. These have been valid and limiting issues in the past, but no longer. Technological advances associated with the so-called maker movement render them moot. We demonstrate this by implementing a fast (∼100 kHz) dynamic clamp system using an inexpensive microcontroller (Teensy 3.6). The overall cost of the system is less than USD$100, and assembling it requires no prior electronics experience. Modifying it—for example, to add Hodgkin–Huxley-style conductances—requires no prior programming experience. The system works together with existing electrophysiology data acquisition systems (for Macintosh, Windows, and Linux); it does not attempt to supplant them. Moreover, the process of assembling, modifying, and using the system constitutes a useful pedagogical exercise for students and researchers with no background but an interest in electronics and programming. We demonstrate the system’s utility by implementing conductances as fast as a transient sodium conductance and as complex as the Ornstein–Uhlenbeck conductances of the “point conductance” model of synaptic background activity. PMID:29085905

  4. Simulating Electrophoresis with Discrete Charge and Drag

    NASA Astrophysics Data System (ADS)

    Mowitz, Aaron J.; Witten, Thomas A.

    A charged asymmetric rigid cluster of colloidal particles in saline solution can respond in exotic ways to an electric field: it may spin or move transversely. These distinctive motions arise from the drag force of the neutralizing countercharge surrounding the cluster. Because of this drag, calculating the motion of arbitrary asymmetric objects with nonuniform charge is impractical by conventional methods. Here we present a new method of simulating electrophoresis, in which we replace the continuous object and the surrounding countercharge with discrete point-draggers, called Stokeslets. The balance of forces imposes a linear, self-consistent relation among the drag and Coulomb forces on the Stokeslets, which allows us to easily determine the object's motion via matrix inversion. By explicitly enforcing charge+countercharge neutrality, the simulation recovers the distinctive features of electrophoretic motion to few-percent accuracy using as few as 1000 Stokeslets. In particular, for uniformly charged objects, we observe the characteristic Smoluchowski independence of mobility on object size and shape. We then discuss electrophoretic motion of asymmetric objects, where our simulation method is particularly advantageous. This work is supported by a Grant from the US-Israel Binational Science Foundation.

  5. Method of making a catalytic reactor for automobile

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vroman, W.R.

    1976-09-07

    A catalytic reactor is made by providing a generally cylindrical catalytic substrate of oval transverse section and clamping the same between paired housing shells to form a housing of oval section spaced from the substrate by means of a pair of wire mesh ropes seated within a corresponding pair of grooves extending around the periphery of the substrate at axially spaced locations. Each rope is compacted from a matrix of multiple layers of resilient stainless steel knitted wire and is interlocked with the housing by means of a pair of inwardly opening channels of the housing spaced axially by anmore » inwardly projecting rib of the housing. The grooves in the substrate are pressed radially into the latter while the same is in a plastic uncured condition, thereby to compact and reinforce the grooves to withstand the localized compressional force of the ropes seated therein after the substrate is cured and hardened and clamped between the housing shells.« less

  6. Search for heavy neutral lepton production in K + decays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cortina Gil, E.; Minucci, E.; Padolski, S.

    Here, a search for heavy neutral lepton production in K + decays using a data sample collected with a minimum bias trigger by the NA62 experiment at CERN in 2015 is reported. Upper limits at the 10 -7 to 10 -6 level are established on the elements of the extended neutrino mixing matrix.

  7. Search for heavy neutral lepton production in K + decays

    DOE PAGES

    Cortina Gil, E.; Minucci, E.; Padolski, S.; ...

    2018-01-28

    Here, a search for heavy neutral lepton production in K + decays using a data sample collected with a minimum bias trigger by the NA62 experiment at CERN in 2015 is reported. Upper limits at the 10 -7 to 10 -6 level are established on the elements of the extended neutrino mixing matrix.

  8. Influence of insulin on glucose metabolism and energy expenditure in septic patients

    PubMed Central

    Rusavy, Zdenek; Sramek, Vladimir; Lacigova, Silvie; Novak, Ivan; Tesinsky, Pavel; Macdonald, Ian A

    2004-01-01

    Introduction It is recognized that administration of insulin with glucose decreases catabolic response in sepsis. The aim of the present study was to compare the effects of two levels of insulinaemia on glucose metabolism and energy expenditure in septic patients and volunteers. Methods Glucose uptake, oxidation and storage, and energy expenditure were measured, using indirect calorimetry, in 20 stable septic patients and 10 volunteers in a two-step hyperinsulinaemic (serum insulin levels 250 and 1250 mIU/l), euglycaemic (blood glucose concentration 5 mmol/l) clamp. Differences between steps of the clamp (from serum insulin 1250 to 250 mIU/l) for all parameters were calculated for each individual, and compared between septic patients and volunteers using the Wilcoxon nonpaired test. Results Differences in glucose uptake and storage were significantly less in septic patients. The differences in glucose oxidation between the groups were not statistically significant. Baseline energy expenditure was significantly higher in septic patients, and there was no significant increase in either step of the clamp in this group; when comparing the two groups, the differences between steps were significantly greater in volunteers. Conclusion A hyperdynamic state of sepsis leads to a decrease in glucose uptake and storage in comparison with healthy volunteers. An increase in insulinaemia leads to an increase in all parameters of glucose metabolism, but the increases in glucose uptake and storage are significantly lower in septic patients. A high level of insulinaemia in sepsis increases glucose uptake and oxidation significantly, but not energy expenditure, in comparison with volunteers. PMID:15312220

  9. Disruption Neutral Point Experiment on Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Granetz, R. S.; Nakamura, Y.

    2000-10-01

    Disruptions of single-null elongated plasmas generally result in loss of vertical position control, leading to a current quench occurring at the top or bottom of the machine, with all the attendant problems of halo and eddy currents flowing in divertor structures. On JT-60U, it has been found that if the plasma is operated with its magnetic axis at a particular height, called the neutral point, the initial vertical drift after a thermal quench is significantly slower than usual, and sometimes can even be arrested, thereby avoiding a current quench in the divertor region entirely. In an ongoing collaboration between MIT and JAERI, the neutral point concept is being tested in Alcator C-Mod, which has a significantly higher plasma elongation than JT-60U (1.65 vs 1.3). Calculations using TSC predict a neutral point at z~=+1 cm above the midplane (a=22 cm). The existence of a neutral point has now been experimentally confirmed, albeit at a height of z=+2.7 cm. The plasma has remained vertically stable for up to 9 ms after the disruption thermal quench, which in principle, is long enough for the PF control system to respond, if programmed appropriately. In addition, the physics of the neutral point stability on C-Mod appears to be somewhat different than that on JT-60U.

  10. Improved lattice computation of proton decay matrix elements

    NASA Astrophysics Data System (ADS)

    Aoki, Yasumichi; Izubuchi, Taku; Shintani, Eigo; Soni, Amarjit

    2017-07-01

    We present an improved result for the lattice computation of the proton decay matrix elements in Nf=2 +1 QCD. In this study, by adopting the error reduction technique of all-mode-averaging, a significant improvement of the statistical accuracy is achieved for the relevant form factor of proton (and also neutron) decay on the gauge ensemble of Nf=2 +1 domain-wall fermions with mπ=0.34 - 0.69 GeV on a 2.7 fm3 lattice, as used in our previous work [1]. We improve the total accuracy of matrix elements to 10-15% from 30-40% for p →π e+ or from 20-40% for p →K ν ¯. The accuracy of the low-energy constants α and β in the leading-order baryon chiral perturbation theory (BChPT) of proton decay are also improved. The relevant form factors of p →π estimated through the "direct" lattice calculation from the three-point function appear to be 1.4 times smaller than those from the "indirect" method using BChPT with α and β . It turns out that the utilization of our result will provide a factor 2-3 larger proton partial lifetime than that obtained using BChPT. We also discuss the use of these parameters in a dark matter model.

  11. Direct vascular control results in less physiologic derangement than proximal aortic clamping in a porcine model of noncompressible extrathoracic torso hemorrhage.

    PubMed

    White, Joseph M; Cannon, Jeremy W; Stannard, Adam; Burkhardt, Gabriel E; Spencer, Jerry R; Williams, Ken; Oh, John S; Rasmussen, Todd E

    2011-11-01

    The optimal method of vascular control and resuscitation in patients with life-threatening, extrathoracic torso hemorrhage remains debated. Guidelines recommend emergency department thoracotomy (EDT) with aortic clamping, although transabdominal aortic clamping followed by vascular control and direct vascular control (DVC) without aortic clamping are alternatives. The objective of this study is to compare the effectiveness of three approaches to extrathoracic torso hemorrhage in a large animal model. Adolescent swine (Sus Scrofa) (mean weight = 80.9 kg) were randomized into three groups all of which had class IV shock established by hemorrhage from an iliac artery injury. Group 1: EDT with thoracic aortic clamping (N = 6); group 2: transabdominal supraceliac aortic clamping (SCC; N = 6); and group 3: DVC of bleeding site without aortic clamping (N = 6). After hemorrhage, EDT or SCC was performed in groups 1 and 2, respectively, with subsequent exploration of the bleeding site and placement of a temporary vascular shunt (TVS). Group 3 (DVC) underwent direct exploration of the injury and placement of a TVS. All groups were resuscitated to predefined physiologic endpoints over 6 hours with repeated measures of central and cerebral perfusion and end-organ function at standardized time points. Postmortem tissue analysis was performed to quantify injury to critical tissue beds. There was no difference in mortality among the groups and no TVS failures. Central aortic pressure, carotid flow, and partial pressure brain tissue oximetry, all demonstrated increases in EDT and SCC after application of the aortic clamp relative to DVC (p < 0.05). During resuscitation, serum lactate levels were higher in EDT compared with SCC and DVC (6.85 vs. 3.08 and 2.15, respectively; p < 0.05) and serum pH in EDT reflected greater acidosis than SCC and DVC (7.24 vs. 7.36 and 7.39, respectively; p < 0.05). EDT and SCC required more intravenous fluid than DVC (2,166 mL and 2,166 mL vs. 667 mL, respectively; p < 0.05) and more vasopressors were used in EDT and SCC compared with DVC (52.1 μg and 43.5 μg vs. 12.4 μg, respectively; p < 0.05). Brain and myocardial tissue stains demonstrated the same degree of acute ischemic changes in all groups. Although aortic clamping increases central and cerebral perfusion, DVC results in less physiologic derangement. The optimal method of aortic control would incorporate the benefits of maintained central pressure with less associated morbidity. Clinical studies evaluating DVC are warranted.

  12. First-principles study of direct and indirect optical absorption in BaSnO3

    NASA Astrophysics Data System (ADS)

    Kang, Youngho; Peelaers, Hartwin; Krishnaswamy, Karthik; Van de Walle, Chris G.

    2018-02-01

    We report first-principles results for the electronic structure and the optical absorption of perovskite BaSnO3 (BSO). BSO has an indirect fundamental gap, and hence, both direct and indirect transitions need to be examined. We assess direct absorption by calculations of the dipole matrix elements. The phonon-assisted indirect absorption spectrum at room temperature is calculated using a quasiclassical approach. Our analysis provides important insights into the optical properties of BSO and addresses several inconsistencies in the results of optical absorption experiments. We shed light on the variety of bandgap values that have been previously reported, concluding that the indirect gap is 2.98 eV and the direct gap is 3.46 eV.

  13. A novel measuring method of clamping force for electrostatic chuck in semiconductor devices

    NASA Astrophysics Data System (ADS)

    Kesheng, Wang; Jia, Cheng; Yin, Zhong; Linhong, Ji

    2016-04-01

    Electrostatic chucks are one of the core components of semiconductor devices. As a key index of electrostatic chucks, the clamping force must be controlled within a reasonable range. Therefore, it is essential to accurately measure the clamping force. To reduce the negative factors influencing measurement precision and repeatability, this article presents a novel method to measure the clamping force and we elaborate both the principle and the key procedure. A micro-force probe component is introduced to monitor, adjust, and eliminate the gap between the wafer and the electrostatic chuck. The contact force between the ruby probe and the wafer is selected as an important parameter to characterize de-chucking, and we have found that the moment of de-chucking can be exactly judged. Moreover, this article derives the formula calibrating equivalent action area of backside gas pressure under real working conditions, which can effectively connect the backside gas pressure at the moment of de-chucking and the clamping force. The experiments were then performed on a self-designed measuring platform. The de-chucking mechanism is discussed in light of our analysis of the experimental data. Determination criteria for de-chucking point are summed up. It is found that the relationship between de-chucking pressure and applied voltage conforms well to quadratic equation. Meanwhile, the result reveals that actual de-chucking behavior is much more complicated than the description given in the classical empirical formula. Project supported by No. 02 National Science and Technology Major Project of China (No. 2011ZX02403-004).

  14. The indirect cost of Patient-Specific Instruments.

    PubMed

    Thienpont, Emmanuel; Paternostre, Frederic; Van Wymeersch, Charles

    2015-09-01

    To calculate the indirect costs of Patient Specific Instruments (PSI) based on an opportunity cost, cost of efforts and a supply chain cost model to compare PSI for value with conventional total knee arthroplasty (TKA). In 81 patients the total (direct+indirect) cost of PSI-assisted TKA was compared with conventional TKA. Surgical times and coronal mechanical alignment were measured to evaluate the effectiveness of the PSI system. Indirect costs (459 euro) make up 40% of the total cost that can run up to 1142 euro for a patient operated with PSI guides. No difference in surgical times or coronal alignment was observed in between both groups. Considering the total cost of PSI no value was found for the use of PSI in primary TKA as measured by surgical times or for obtaining a neutral mechanical axis in the coronal plane.

  15. NELL-1 increases pre-osteoblast mineralization using both phosphate transporter Pit1 and Pit2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cowan, Catherine M.; Dental and Craniofacial Research Institute and Section of Orthodontics, School of Dentistry, University of California, Los Angeles, 40833 Le Conte Ave, Los Angeles, CA 90095; Zhang, Xinli

    2012-06-08

    Highlights: Black-Right-Pointing-Pointer NELL-1 accelerates extracellular matrix mineralization in MC3T3-E1 pre-osteoblasts. Black-Right-Pointing-Pointer NELL-1 significantly increases intracellular inorganic phosphate levels. Black-Right-Pointing-Pointer NELL-1 positively regulates osteogenesis but not proliferation in MC3T3-E1 cells. Black-Right-Pointing-Pointer NELL-1 regulates inorganic phosphate transporter activity. -- Abstract: NELL-1 is a potent osteoinductive molecule that enhances bone formation in multiple animal models through currently unidentified pathways. In the present manuscript, we hypothesized that NELL-1 may regulate osteogenic differentiation accompanied by alteration of inorganic phosphate (Pi) entry into the osteoblast via sodium dependent phosphate (NaPi) transporters. To determine this, MC3T3-E1 pre-osteoblasts were cultured in the presence of recombinant human (rh)NELL-1 ormore » rhBMP-2. Analysis was performed for intracellular Pi levels through malachite green staining, Pit-1 and Pit-2 expression, and forced upregulation of Pit-1 and Pit-2. Results showed rhNELL-1 to increase MC3T3-E1 matrix mineralization and Pi influx associated with activation of both Pit-1 and Pit-2 channels, with significantly increased Pit-2 production. In contrast, Pi transport elicited by rhBMP-2 showed to be associated with increased Pit-1 production only. Next, neutralizing antibodies against Pit-1 and Pit-2 completely abrogated the Pi influx effect of rhNELL-1, suggesting rhNELL-1 is dependent on both transporters. These results identify one potential mechanism of action for rhNELL-1 induced osteogenesis and highlight a fundamental difference between NELL-1 and BMP-2 signaling.« less

  16. Intratracheal IL-6 protects against lung inflammation in direct, but not indirect, causes of acute lung injury in mice.

    PubMed

    Bhargava, Rhea; Janssen, William; Altmann, Christopher; Andrés-Hernando, Ana; Okamura, Kayo; Vandivier, R William; Ahuja, Nilesh; Faubel, Sarah

    2013-01-01

    Serum and bronchoalveolar fluid IL-6 are increased in patients with acute respiratory distress syndrome (ARDS) and predict prolonged mechanical ventilation and poor outcomes, although the role of intra-alveolar IL-6 in indirect lung injury is unknown. We investigated the role of endogenous and exogenous intra-alveolar IL-6 in AKI-mediated lung injury (indirect lung injury), intraperitoneal (IP) endotoxin administration (indirect lung injury) and, for comparison, intratracheal (IT) endotoxin administration (direct lung injury) with the hypothesis that IL-6 would exert a pro-inflammatory effect in these causes of acute lung inflammation. Bronchoalveolar cytokines (IL-6, CXCL1, TNF-α, IL-1β, and IL-10), BAL fluid neutrophils, lung inflammation (lung cytokines, MPO activity [a biochemical marker of neutrophil infiltration]), and serum cytokines were determined in adult male C57Bl/6 mice with no intervention or 4 hours after ischemic AKI (22 minutes of renal pedicle clamping), IP endotoxin (10 µg), or IT endotoxin (80 µg) with and without intratracheal (IT) IL-6 (25 ng or 200 ng) treatment. Lung inflammation was similar after AKI, IP endotoxin, and IT endotoxin. BAL fluid IL-6 was markedly increased after IT endotoxin, and not increased after AKI or IP endotoxin. Unexpectedly, IT IL-6 exerted an anti-inflammatory effect in healthy mice characterized by reduced BAL fluid cytokines. IT IL-6 also exerted an anti-inflammatory effect in IT endotoxin characterized by reduced BAL fluid cytokines and lung inflammation; IT IL-6 had no effect on lung inflammation in AKI or IP endotoxin. IL-6 exerts an anti-inflammatory effect in direct lung injury from IT endotoxin, yet has no role in the pathogenesis or treatment of indirect lung injury from AKI or IP endotoxin. Since intra-alveolar inflammation is important in the pathogenesis of direct, but not indirect, causes of lung inflammation, IT anti-inflammatory treatments may have a role in direct, but not indirect, causes of ARDS.

  17. Is early cord clamping, delayed cord clamping or cord milking best?

    PubMed

    Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan

    2018-04-01

    To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p < .05) lower in the early cord clamping group compared with the other two groups. The disulfide/total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.

  18. Radio frequency sustained ion energy

    DOEpatents

    Jassby, Daniel L.; Hooke, William M.

    1977-01-01

    Electromagnetic (E.M.) energy injection method and apparatus for producing and sustaining suprathermal ordered ions in a neutral, two-ion-species, toroidal, bulk equilibrium plasma. More particularly, the ions are produced and sustained in an ordered suprathermal state of existence above the average energy and velocity of the bulk equilibrium plasma by resonant rf energy injection in resonance with the natural frequency of one of the ion species. In one embodiment, the electromagnetic energy is injected to clamp the energy and velocity of one of the ion species so that the ion energy is increased, sustained, prolonged and continued in a suprathermal ordered state of existence containing appreciable stored energy that counteracts the slowing down effects of the bulk equilibrium plasma drag. Thus, selective deuteron absorption may be used for ion-tail creation by radio-frequency excitation alone. Also, the rf can be used to increase the fusion output of a two-component neutral injected plasma by selective heating of the injected deuterons.

  19. Structure of the Ebola Virus Glycoprotein Bound to An Antibody From a Human Survivor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, J.E.; Fusco, M.L.; Hessell, A.J.

    2009-05-20

    Ebola virus (EBOV) entry requires the surface glycoprotein (GP) to initiate attachment and fusion of viral and host membranes. Here we report the crystal structure of EBOV GP in its trimeric, pre-fusion conformation (GP1+GP2) bound to a neutralizing antibody, KZ52, derived from a human survivor of the 1995 Kikwit outbreak. Three GP1 viral attachment subunits assemble to form a chalice, cradled by the GP2 fusion subunits, while a novel glycan cap and projected mucin-like domain restrict access to the conserved receptor-binding site sequestered in the chalice bowl. The glycocalyx surrounding GP is likely central to immune evasion and may explainmore » why survivors have insignificant neutralizing antibody titres. KZ52 recognizes a protein epitope at the chalice base where it clamps several regions of the pre-fusion GP2 to the amino terminus of GP1. This structure provides a template for unraveling the mechanism of EBOV GP-mediated fusion and for future immunotherapeutic development.« less

  20. Millicharge or decay: a critical take on Minimal Dark Matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nobile, Eugenio Del; Dipartimento di Fisica e Astronomia “G. Galilei”, Università di Padova and INFN, Sezione di Padova,Via Marzolo 8, 35131 Padova; Nardecchia, Marco

    2016-04-26

    Minimal Dark Matter (MDM) is a theoretical framework highly appreciated for its minimality and yet its predictivity. Of the two only viable candidates singled out in the original analysis, the scalar eptaplet has been found to decay too quickly to be around today, while the fermionic quintuplet is now being probed by indirect Dark Matter (DM) searches. It is therefore timely to critically review the MDM paradigm, possibly pointing out generalizations of this framework. We propose and explore two distinct directions. One is to abandon the assumption of DM electric neutrality in favor of absolutely stable, millicharged DM candidates whichmore » are part of SU(2){sub L} multiplets with integer isospin. Another possibility is to lower the cutoff of the model, which was originally fixed at the Planck scale, to allow for DM decays. We find new viable MDM candidates and study their phenomenology in detail.« less

  1. Millicharge or decay: a critical take on Minimal Dark Matter

    DOE PAGES

    Nobile, Eugenio Del; Nardecchia, Marco; Panci, Paolo

    2016-04-26

    Minimal Dark Matter (MDM) is a theoretical framework highly appreciated for its minimality and yet its predictivity. Of the two only viable candidates singled out in the original analysis, the scalar eptaplet has been found to decay too quickly to be around today, while the fermionic quintuplet is now being probed by indirect Dark Matter (DM) searches. It is therefore timely to critically review the MDM paradigm, possibly pointing out generalizations of this framework. We propose and explore two distinct directions. One is to abandon the assumption of DM electric neutrality in favor of absolutely stable, millicharged DM candidates whichmore » are part of SU(2)L multiplets with integer isospin. Another possibility is to lower the cutoff of the model, which was originally fixed at the Planck scale, to allow for DM decays. We find new viable MDM candidates and study their phenomenology in detail.« less

  2. Infrared Spectroscopy of Matrix-Isolated Polycyclic Aromatic Nitrogen Heterocycles (PANHs)

    NASA Technical Reports Server (NTRS)

    Mattioda, A. L.; Hudgins, D. M.; Bauschlicher, C. W.; Allamandola, L. J.; Biemesderfer, C. D.; Rosi, M.

    2002-01-01

    The mid-infrared spectra of the nitrogen-containing heterocyclic polycyclic aromatic compounds 1-azabenz[a]-anthracene; 2-azabenz[a]anthracene; 1-azachrysene; 2-azachrysene; 4-azachrysene; 2-azapyrene, and 7,8 benzoquinoline in their neutral and cation forms were investigated. The spectra of these species isolated in an argon matrix have been measured. Band frequencies and intensities were tabulated and these data compared with spectra computed using density functional theory at the B3LYP level. The overall agreement between experiment and theory is quite good, in keeping with earlier results on homonuclear polycyclic aromatic hydrocarbons. The differences between the spectral properties of nitrogen bearing aromatics and non-substituted, neutral polycyclic aromatic hydrocarbons will be discussed.

  3. Fluorescence Excitation-Emission Matrix Regional Integration to Quantify Spectra for Dissolved Organic Matter

    USGS Publications Warehouse

    Chen, W.; Westerhoff, P.; Leenheer, J.A.; Booksh, K.

    2003-01-01

    Excitation-emission matrix (EEM) fluorescence spectroscopy has been widely used to characterize dissolved organic matter (DOM) in water and soil. However, interpreting the >10,000 wavelength-dependent fluorescence intensity data points represented in EEMs has posed a significant challenge. Fluorescence regional integration, a quantitative technique that integrates the volume beneath an EEM, was developed to analyze EEMs. EEMs were delineated into five excitation-emission regions based on fluorescence of model compounds, DOM fractions, and marine waters or freshwaters. Volumetric integration under the EEM within each region, normalized to the projected excitation-emission area within that region and dissolved organic carbon concentration, resulted in a normalized region-specific EEM volume (??i,n). Solid-state carbon nuclear magnetic resonance (13C NMR), Fourier transform infrared (FTIR) analysis, ultraviolet-visible absorption spectra, and EEMs were obtained for standard Suwannee River fulvic acid and 15 hydrophobic or hydrophilic acid, neutral, and base DOM fractions plus nonfractionated DOM from wastewater effluents and rivers in the southwestern United States. DOM fractions fluoresced in one or more EEM regions. The highest cumulative EEM volume (??T,n = ????i,n) was observed for hydrophobic neutral DOM fractions, followed by lower ??T,n values for hydrophobic acid, base, and hydrophilic acid DOM fractions, respectively. An extracted wastewater biomass DOM sample contained aromatic protein- and humic-like material and was characteristic of bacterial-soluble microbial products. Aromatic carbon and the presence of specific aromatic compounds (as indicated by solid-state 13C NMR and FTIR data) resulted in EEMs that aided in differentiating wastewater effluent DOM from drinking water DOM.

  4. FPGA in-the-loop simulations of cardiac excitation model under voltage clamp conditions

    NASA Astrophysics Data System (ADS)

    Othman, Norliza; Adon, Nur Atiqah; Mahmud, Farhanahani

    2017-01-01

    Voltage clamp technique allows the detection of single channel currents in biological membranes in identifying variety of electrophysiological problems in the cellular level. In this paper, a simulation study of the voltage clamp technique has been presented to analyse current-voltage (I-V) characteristics of ion currents based on Luo-Rudy Phase-I (LR-I) cardiac model by using a Field Programmable Gate Array (FPGA). Nowadays, cardiac models are becoming increasingly complex which can cause a vast amount of time to run the simulation. Thus, a real-time hardware implementation using FPGA could be one of the best solutions for high-performance real-time systems as it provides high configurability and performance, and able to executes in parallel mode operation. For shorter time development while retaining high confidence results, FPGA-based rapid prototyping through HDL Coder from MATLAB software has been used to construct the algorithm for the simulation system. Basically, the HDL Coder is capable to convert the designed MATLAB Simulink blocks into hardware description language (HDL) for the FPGA implementation. As a result, the voltage-clamp fixed-point design of LR-I model has been successfully conducted in MATLAB Simulink and the simulation of the I-V characteristics of the ionic currents has been verified on Xilinx FPGA Virtex-6 XC6VLX240T development board through an FPGA-in-the-loop (FIL) simulation.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ristow, Sandra S.; Arnzen, Jeanene M.; Leong, JoAnn Ching

    Seventeen strains of infectious hematopoietic necrosis virus (IHNV) from different geographical regions and from different fish stocks were typed by polyacrylamide gel electrophoresis, indirect fluorescence with 27 monoclonal antibodies against both the G and N proteins of the virus, and by serum neutralization with six monoclonal anti-glycoprotein antibodies. In addition, many other IHNV isolates have been examined. Studying the isolates with the antibodies has shown that a greater amount of variation exists between isolates than was first predicted by the application of the polyacrylamide technique. Isolates within electrophoretic types I-V may be further classified according to their reactions with themore » monoclonal antibodies in indirect fluorescence. Serum neutralization with selected anti-glycoprotein antibodies in conjunction with fluorescence analysis confirms one of the original findings of Hsu et al. (1986) that two different species in a single facility can be infected with the same isolate. Variation among isolates as measured by reactivity with the monoclonal library appears to be greater within the G protein than within the N protein sequence. 9 refs., 7 figs., 6 tabs.« less

  6. AMS-02 positron excess and indirect detection of three-body decaying dark matter

    NASA Astrophysics Data System (ADS)

    Cheng, Hsin-Chia; Huang, Wei-Chih; Huang, Xiaoyuan; Low, Ian; Sming Tsai, Yue-Lin; Yuan, Qiang

    2017-03-01

    We consider indirect detection of meta-stable dark matter particles decaying into a stable neutral particle and a pair of standard model fermions. Due to the softer energy spectra from the three-body decay, such models could potentially explain the AMS-02 positron excess without being constrained by the Fermi-LAT gamma-ray data and the cosmic ray anti-proton measurements. We scrutinize over different final state fermions, paying special attention to handling of the cosmic ray background and including various contributions from cosmic ray propagation with the help of the LIKEDM package. It is found that primary decays into an electron-positron pair and a stable neutral particle could give rise to the AMS-02 positron excess and, at the same time, stay unscathed against the gamma-ray and anti-proton constraints. Decays to a muon pair or a mixed flavor electron-muon pair may also be viable depending on the propagation models. Decays to all other standard model fermions are severely disfavored.

  7. Production of monoclonal antibody against ORF72 of koi herpesvirus isolated in Taiwan.

    PubMed

    Tu, Chien; Lu, Yi-Ping; Hsieh, Chia-Yu; Huang, Su-Ming; Chang, Shao-Kuang; Chen, Meei-Mei

    2014-03-01

    A monoclonal antibody (MAb) was generated against the capsid protein (ORF 72) of koi herpesvirus (KHV) isolated from diseased koi Cyprinus carpio in Taiwan. The clone of MAb-B2 was obtained by immunizing mice with whole virus particles and further identified using indirect enzyme-linked immunosorbent assay and Western blot assay. In addition, it detected KHV in KHV-infected cells but not in those of mock-infected cells as demonstrated by indirect immunofluorescence assay. The neutralization test showed that MAb-B2 neutralized KHV. Furthermore, we uncovered that MAb-B2 recognizes the ORF72 of KHV as revealed by liquid chromatography-tandem mass spectrometry and Western blot assays. Additionally, MAb-B2 has been used as a diagnostic tool for detection of KHV in clinical samples by immunohistochemistry. Collectively, our results indicated that MAb-B2 could be used in the development of a diagnostic kit for diagnosis of KHV infections and ORF72 protein of KHV might be a candidate for future vaccine development.

  8. Analysis of the error of the developed method of determination the active conductivity reducing the insulation level between one phase of the network and ground, and insulation parameters in a non-symmetric network with isolated neutral with voltage above 1000 V

    NASA Astrophysics Data System (ADS)

    Utegulov, B. B.

    2018-02-01

    In the work the study of the developed method was carried out for reliability by analyzing the error in indirect determination of the insulation parameters in an asymmetric network with an isolated neutral voltage above 1000 V. The conducted studies of the random relative mean square errors show that the accuracy of indirect measurements in the developed method can be effectively regulated not only by selecting a capacitive additional conductivity, which are connected between phases of the electrical network and the ground, but also by the selection of measuring instruments according to the accuracy class. When choosing meters with accuracy class of 0.5 with the correct selection of capacitive additional conductivity that are connected between the phases of the electrical network and the ground, the errors in measuring the insulation parameters will not exceed 10%.

  9. A novel indirect ELISA based on glycoprotein Gn for the detection of IgG antibodies against Rift Valley fever virus in small ruminants.

    PubMed

    Jäckel, S; Eiden, M; Balkema-Buschmann, A; Ziller, M; van Vuren, P Jansen; Paweska, J T; Groschup, M H

    2013-10-01

    Rift Valley fever virus (RVFV) is an emerging zoonotic pathogen that causes high morbidity and mortality in humans and livestock. In this paper, we describe the cloning, expression and purification of RVFV glycoprotein Gn and its application as a diagnostic antigen in an indirect ELISA for the specific detection of RVF IgG antibodies in sheep and goats. The performance of this Gn based ELISA is validated using a panel of almost 2000 field samples from sheep and goats from Mozambique, Senegal, Uganda and Yemen. All serum samples were also tested by virus neutralization test (VNT), the gold standard method for RVFV serological testing. Compared to the VNT results the Gn based ELISA proved to have an excellent sensitivity (94.56%) and specificity (95.57%). Apart from establishing this new diagnostic assay, these results also demonstrate a close correlation between the presence of RVFV Gn and neutralizing antibodies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Health monitoring method for composite materials

    DOEpatents

    Watkins, Jr., Kenneth S.; Morris, Shelby J [Hampton, VA

    2011-04-12

    An in-situ method for monitoring the health of a composite component utilizes a condition sensor made of electrically conductive particles dispersed in a polymeric matrix. The sensor is bonded or otherwise formed on the matrix surface of the composite material. Age-related shrinkage of the sensor matrix results in a decrease in the resistivity of the condition sensor. Correlation of measured sensor resistivity with data from aged specimens allows indirect determination of mechanical damage and remaining age of the composite component.

  11. Design of biomimetic cellular scaffolds for co-culture system and their application

    PubMed Central

    Kook, Yun-Min; Jeong, Yoon; Lee, Kangwon; Koh, Won-Gun

    2017-01-01

    The extracellular matrix of most natural tissues comprises various types of cells, including fibroblasts, stem cells, and endothelial cells, which communicate with each other directly or indirectly to regulate matrix production and cell functionality. To engineer multicellular interactions in vitro, co-culture systems have achieved tremendous success achieving a more realistic microenvironment of in vivo metabolism than monoculture system in the past several decades. Recently, the fields of tissue engineering and regenerative medicine have primarily focused on three-dimensional co-culture systems using cellular scaffolds, because of their physical and biological relevance to the extracellular matrix of actual tissues. This review discusses several materials and methods to create co-culture systems, including hydrogels, electrospun fibers, microfluidic devices, and patterning for biomimetic co-culture system and their applications for specific tissue regeneration. Consequently, we believe that culture systems with appropriate physical and biochemical properties should be developed, and direct or indirect cell–cell interactions in the remodeled tissue must be considered to obtain an optimal tissue-specific microenvironment. PMID:29081966

  12. Design of biomimetic cellular scaffolds for co-culture system and their application.

    PubMed

    Kook, Yun-Min; Jeong, Yoon; Lee, Kangwon; Koh, Won-Gun

    2017-01-01

    The extracellular matrix of most natural tissues comprises various types of cells, including fibroblasts, stem cells, and endothelial cells, which communicate with each other directly or indirectly to regulate matrix production and cell functionality. To engineer multicellular interactions in vitro, co-culture systems have achieved tremendous success achieving a more realistic microenvironment of in vivo metabolism than monoculture system in the past several decades. Recently, the fields of tissue engineering and regenerative medicine have primarily focused on three-dimensional co-culture systems using cellular scaffolds, because of their physical and biological relevance to the extracellular matrix of actual tissues. This review discusses several materials and methods to create co-culture systems, including hydrogels, electrospun fibers, microfluidic devices, and patterning for biomimetic co-culture system and their applications for specific tissue regeneration. Consequently, we believe that culture systems with appropriate physical and biochemical properties should be developed, and direct or indirect cell-cell interactions in the remodeled tissue must be considered to obtain an optimal tissue-specific microenvironment.

  13. Triple bar, high efficiency mechanical sealer

    DOEpatents

    Pak, Donald J.; Hawkins, Samantha A.; Young, John E.

    2013-03-19

    A clamp with a bottom clamp bar that has a planar upper surface is provided. The clamp may also include a top clamp bar connected to the bottom clamp bar, and a pressure distribution bar between the top clamp bar and the bottom clamp bar. The pressure distribution bar may have a planar lower surface in facing relation to the upper surface of the bottom clamp bar. An object is capable of being disposed in a clamping region between the upper surface and the lower surface. The width of the planar lower surface may be less than the width of the upper surface within the clamping region. Also, the pressure distribution bar may be capable of being urged away from the top clamp bar and towards the bottom clamp bar.

  14. Real-Time Kinetic Modeling of Voltage-Gated Ion Channels Using Dynamic Clamp

    PubMed Central

    Milescu, Lorin S.; Yamanishi, Tadashi; Ptak, Krzysztof; Mogri, Murtaza Z.; Smith, Jeffrey C.

    2008-01-01

    We propose what to our knowledge is a new technique for modeling the kinetics of voltage-gated ion channels in a functional context, in neurons or other excitable cells. The principle is to pharmacologically block the studied channel type, and to functionally replace it with dynamic clamp, on the basis of a computational model. Then, the parameters of the model are modified in real time (manually or automatically), with the objective of matching the dynamical behavior of the cell (e.g., action potential shape and spiking frequency), but also the transient and steady-state properties of the model (e.g., those derived from voltage-clamp recordings). Through this approach, one may find a model and parameter values that explain both the observed cellular dynamics and the biophysical properties of the channel. We extensively tested the method, focusing on Nav models. Complex Markov models (10–12 states or more) could be accurately integrated in real time at >50 kHz using the transition probability matrix, but not the explicit Euler method. The practicality of the technique was tested with experiments in raphe pacemaker neurons. Through automated real-time fitting, a Hodgkin-Huxley model could be found that reproduced well the action potential shape and the spiking frequency. Adding a virtual axonal compartment with a high density of Nav channels further improved the action potential shape. The computational procedure was implemented in the free QuB software, running under Microsoft Windows and featuring a friendly graphical user interface. PMID:18375511

  15. Positioning of the sensor cell on the sensing area using cell trapping pattern in incubation type planar patch clamp biosensor.

    PubMed

    Wang, Zhi-Hong; Takada, Noriko; Uno, Hidetaka; Ishizuka, Toru; Yawo, Hiromu; Urisu, Tsuneo

    2012-08-01

    Positioning the sensor cell on the micropore of the sensor chip and keeping it there during incubation are problematic tasks for incubation type planar patch clamp biosensors. To solve these problems, we formed on the Si sensor chip's surface a cell trapping pattern consisting of a lattice pattern with a round area 5 μm deep and with the micropore at the center of the round area. The surface of the sensor chip was coated with extra cellular matrix collagen IV, and HEK293 cells on which a chimera molecule of channel-rhodopsin-wide-receiver (ChR-WR) was expressed, were then seeded. We examined the effects of this cell trapping pattern on the biosensor's operation. In the case of a flat sensor chip without a cell trapping pattern, it took several days before the sensor cell covered the micropore and formed an almost confluent state. As a result, multi-cell layers easily formed and made channel current measurements impossible. On the other hand, the sensor chip with cell trapping pattern easily trapped cells in the round area, and formed the colony consisted of the cell monolayer covering the micropore. A laser (473 nm wavelength) induced channel current was observed from the whole cell arrangement formed using the nystatin perforation technique. The observed channel current characteristics matched measurements made by using a pipette patch clamp. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Post clamp

    NASA Technical Reports Server (NTRS)

    Ramsey, John K. (Inventor); Meyn, Erwin H. (Inventor)

    1990-01-01

    A pair of spaced collars are mounted at right angles on a clamp body by retaining rings which enable the collars to rotate with respect to the clamp body. Mounting posts extend through aligned holes in the collars and clamp body. Each collar can be clamped onto the inserted post while the clamp body remains free to rotate about the post and collar. The clamp body is selectively clamped onto each post.

  17. Insulin sensitivity indices: a proposal of cut-off points for simple identification of insulin-resistant subjects.

    PubMed

    Radikova, Z; Koska, J; Huckova, M; Ksinantova, L; Imrich, R; Vigas, M; Trnovec, T; Langer, P; Sebokova, E; Klimes, I

    2006-05-01

    Demanding measurement of insulin sensitivity using clamp methods does not simplify the identification of insulin resistant subjects in the general population. Other approaches such as fasting- or oral glucose tolerance test-derived insulin sensitivity indices were proposed and validated with the euglycemic clamp. Nevertheless, a lack of reference values for these indices prevents their wider use in epidemiological studies and clinical practice. The aim of our study was therefore to define the cut-off points of insulin resistance indices as well as the ranges of the most frequently obtained values for selected indices. A standard 75 g oral glucose tolerance test was carried out in 1156 subjects from a Caucasian rural population with no previous evidence of diabetes or other dysglycemias. Insulin resistance/sensitivity indices (HOMA-IR, HOMA-IR2, ISI Cederholm, and ISI Matsuda) were calculated. The 75th percentile value as the cut-off point to define IR corresponded with a HOMA-IR of 2.29, a HOMA-IR2 of 1.21, a 25th percentile for ISI Cederholm, and ISI Matsuda of 57 and 5.0, respectively. For the first time, the cut-off points for selected indices and their most frequently obtained values were established for groups of subjects as defined by glucose homeostasis and BMI. Thus, insulin-resistant subjects can be identified using this simple approach.

  18. Detecting Damage in Ceramic Matrix Composites Using Electrical Resistance

    NASA Technical Reports Server (NTRS)

    Smith, Craig E.; Gyekenyesi, Andrew

    2011-01-01

    The majority of damage in SiC/SiC ceramic matrix composites subjected to monotonic tensile loads is in the form of distributed matrix cracks. These cracks initiate near stress concentrations, such as 90 deg fiber tows or large matrix pores and continue to accumulate with additional stress until matrix crack saturation is achieved. Such damage is difficult to detect with conventional nondestructive evaluation techniques (immersion ultrasonics, x-ray, etc.). Monitoring a specimen.s electrical resistance change provides an indirect approach for monitoring matrix crack density. Sylramic-iBN fiber- reinforced SiC composites with a melt infiltrated (MI) matrix were tensile tested at room temperature. Results showed an increase in resistance of more than 500% prior to fracture, which can be detected either in situ or post-damage. A relationship between resistance change and matrix crack density was also determined.

  19. Detecting Cracks in Ceramic Matrix Composites by Electrical Resistance

    NASA Technical Reports Server (NTRS)

    Smith, Craig; Gyekenyesi, Andrew

    2011-01-01

    The majority of damage in SiC/SiC ceramic matrix composites subjected to monotonic tensile loads is in the form of distributed matrix cracks. These cracks initiate near stress concentrations, such as 90o fiber tows or large matrix pores and continue to accumulate with additional stress until matrix crack saturation is achieved. Such damage is difficult to detect with conventional nondestructive evaluation techniques (immersion ultrasonics, x-ray, etc.). Monitoring a specimen.s electrical resistance change provides an indirect approach for monitoring matrix crack density. Sylramic-iBN fiber- reinforced SiC composites with a melt infiltrated (MI) matrix were tensile tested at room temperature. Results showed an increase in resistance of more than 500% prior to fracture, which can be detected either in situ or post-damage. A relationship between resistance change and matrix crack density was also determined.

  20. Mechanistic Basis of Sensitivity/Resistance Towards Anti-Cancer Drugs Targeting Topoisomerase II

    DTIC Science & Technology

    2005-04-01

    alkylation of hstopo Ilac by both anticancer drugs such as menadione and chemopreventive compounds such as diallyl trisulfide (DAT), which has been...putatively identified menadione as having reacted with Cys427 by matrix-assisted laser desorption ionization (MALDI) MS. Preliminary results from LC-ESI-MS...suggest that menadione reacts with additional thiol residues, albeit through indirect evidence. The indirect evidence is similar to that mentioned

  1. Mechanistic Basis of Sensitivity/Resistance Towards Anti-cancer Drugs Targeting Topoisomerase II

    DTIC Science & Technology

    2006-04-01

    of hstopo IIα by both anticancer drugs such as menadione and chemopreventive compounds such as 9 diallyl trisulfide (DAT), which has been shown to...we putatively identified menadione as having reacted with Cys427 by matrix-assisted laser desorption ionization (MALDI) MS. Preliminary results...from LC- ESI-MS suggest that menadione reacts with additional thiol residues, albeit through indirect evidence. The indirect evidence is similar to

  2. Use of the Satinsky clamp for hilar clamping during robotic partial nephrectomy: indications, technique, and multi-center outcomes.

    PubMed

    Abdullah, Newaj; Rahbar, Haider; Barod, Ravi; Dalela, Deepansh; Larson, Jeff; Johnson, Michael; Mass, Alon; Zargar, Homayoun; Kaouk, Jihad; Allaf, Mohamad; Bhayani, Sam; Stifelman, Michael; Rogers, Craig

    2017-03-01

    A Satinsky clamp may be a backup option for hilar clamping during robotic partial nephrectomy (RPN) if there are challenges with application of bulldog clamps, but there are potential safety concerns. We evaluate outcomes of RPN using Satinsky vs. bulldog clamps, and provide tips for safe use of the Satinsky as a backup option. Using a multi-center database, we identified 1073 patients who underwent RPN between 2006 and 2013, and had information available about method of hilar clamping (bulldog clamp vs. Satinsky clamp). Patient baseline characteristics, tumor features, and perioperative outcomes were compared between the Satinsky and bulldog clamp groups. A Satinsky clamp was used for hilar clamping in 94 (8.8 %) RPN cases, and bulldog clamps were used in 979 (91.2 %) cases. The use of a Satinsky clamp was associated with greater operative time (198 vs. 175 min, p < 0.001), estimated blood loss (EBL, 200 vs. 100 ml, p < 0.001), warm ischemia time (WIT, 20 vs. 19 min, p = 0.036), transfusion rate (12.8 vs. 4.8 %, p = 0.001), and hospital stay (3 vs. 2 days, p < 0.001). Tumor characteristics and number of renal vessels were similar between groups. There were six intraoperative complications in the Satinsky clamp group, but none were directly related to the Satinsky clamp. On multivariable analysis, the use of the Satinsky clamp was not associated with increase in intraoperative or Clavien ≥3 postoperative complications, positive surgical margin rate or percentage change in estimated glomerular filtration rate. A Satinsky clamp can be a backup option for hilar clamping during challenging RPN cases, but requires careful technique, and was rarely necessary.

  3. Effect of sterilization on stiffness and dimensional stability of rubber-dam clamps.

    PubMed

    Giebink, D L; Mathieu, G P; Hondrum, S O

    1996-01-01

    Simulated clinical conditions were used to test the effect of sterilization on rubber-dam clamp stiffness and dimension. Sixty Hygienic and Ivory W7 clamps were either steam or dry heat sterilized and compared to controls. Stiffness and dimensional change between Ivory clamp groups was significant (p<.0001); the sterilized clamps showed less change than the controls. Hygienic groups showed a significant different between the control and dry heat groups (p<.05); the sterilized clamps showed less change than the controls. The change in stiffness and interjaw width for all Ivory clamps compared to all Hygienic clamps was significant (p<.0001). The Hygienic clamps changes less than the Ivory clamps. The results indicate that steam and dry heat sterilization do not affect retention of rubber-dam clamps.

  4. FoxO1 integrates direct and indirect effects of insulin on hepatic glucose production and glucose utilization

    PubMed Central

    O-Sullivan, InSug; Zhang, Wenwei; Wasserman, David H.; Liew, Chong Wee; Liu, Jonathan; Paik, Jihye; DePinho, Ronald A.; Stolz, Donna Beer; Kahn, C. Ronald; Schwartz, Michael W.; Unterman, Terry G.

    2016-01-01

    FoxO proteins are major targets of insulin action. To better define the role of FoxO1 in mediating insulin effects in the liver, we generated liver-specific insulin receptor knockout (LIRKO) and IR/FoxO1 double knockout (LIRFKO) mice. Here we show that LIRKO mice are severely insulin resistant based on glucose, insulin and C-peptide levels, and glucose and insulin tolerance tests, and genetic deletion of hepatic FoxO1 reverses these effects. 13C-glucose and insulin clamp studies indicate that regulation of both hepatic glucose production (HGP) and glucose utilization is impaired in LIRKO mice, and these defects are also restored in LIRFKO mice corresponding to changes in gene expression. We conclude that (1) inhibition of FoxO1 is critical for both direct (hepatic) and indirect effects of insulin on HGP and utilization, and (2) extrahepatic effects of insulin are sufficient to maintain normal whole-body and hepatic glucose metabolism when liver FoxO1 activity is disrupted. PMID:25963540

  5. Clamping characteristics study on different types of clamping unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiao, Zhiwei; Liu, Haichao; Xie, Pengcheng

    2015-05-22

    Plastic products are becoming more and more widely used in aerospace, IT, digital electronics and many other fields. With the development of technology, the requirement of product precision is getting higher and higher. However, type and working performance of clamping unit play a decisive role in product precision. Clamping characteristics of different types of clamping unit are discussed in this article, which use finite element numerical analysis method through the software ABAQUS to study the clamping uniformity, and detect the clamping force repeatability precision. The result shows that compared with toggled three-platen clamping unit, clamping characteristics of internal circulation two-platenmore » clamping unit are better, for instance, its mold cavity deformation and force that bars and mold parting surface suffered are more uniform, and its clamping uniformity and repeatability precision is also better.« less

  6. Design and analysis on thermal adaptive clamping device for PPMgLN crystal used in solid state laser

    NASA Astrophysics Data System (ADS)

    Yan, Conglin; Chen, Yongliang; Zhang, Wei

    2015-02-01

    The quality of clamping device for PPMgLN crystal has a vital influence on the optical property of solid-state laser. It has highly requirements of work stability and environmental adaptation ability, especially the thermal adaptation under high temperature differences. To achieve thermal adaptation, structural stiffness will be unavoidably weakened. How to keep both enough stiffness and thermal adaptation as far as possible is the key design point and also difficult point. In this paper, a kind of flexible thermal release unit which can work permanent under 130+/-10°C is studied. Thermal compensation principle and flexible thermal release theory are applied. Analysis results indicate that this device can effectively decreased the thermal stress of the crystal from 85MPa to 0.66MPa. The results of the vibration resistance test on the optical axis direction of the crystal indicate that the device can provide at least 5.62N to resistant 57.2g impact vibration and 18.5g impact vibration in the side direction, well satisfied the requirements of ability to resistant 6g impact vibration.

  7. Parallel multipoint recording of aligned and cultured neurons on micro channel array toward cellular network analysis.

    PubMed

    Tonomura, Wataru; Moriguchi, Hiroyuki; Jimbo, Yasuhiko; Konishi, Satoshi

    2010-08-01

    This paper describes an advanced Micro Channel Array (MCA) for recording electrophysiological signals of neuronal networks at multiple points simultaneously. The developed MCA is designed for neuronal network analysis which has been studied by the co-authors using the Micro Electrode Arrays (MEA) system, and employs the principles of extracellular recordings. A prerequisite for extracellular recordings with good signal-to-noise ratio is a tight contact between cells and electrodes. The MCA described herein has the following advantages. The electrodes integrated around individual micro channels are electrically isolated to enable parallel multipoint recording. Reliable clamping of a targeted cell through micro channels is expected to improve the cellular selectivity and the attachment between the cell and the electrode toward steady electrophysiological recordings. We cultured hippocampal neurons on the developed MCA. As a result, the spontaneous and evoked spike potentials could be recorded by sucking and clamping the cells at multiple points. In this paper, we describe the design and fabrication of the MCA and the successful electrophysiological recordings leading to the development of an effective cellular network analysis device.

  8. Arc spray fabrication of metal matrix composite monotape

    NASA Technical Reports Server (NTRS)

    Westfall, L. J. (Inventor)

    1985-01-01

    Arc metal spraying is used to spray liquid metal onto an array of high strength fibers that were previously wound onto a large drum contained inside a controlled atmosphere chamber. This chamber is first evacuated to remove gaseous contaminants and then backfilled with a neutral gas up to atmospheric pressure. This process is used to produce a large size metal matrix composite monotape.

  9. DISSOLUTION OF URANIUM FUELS BY MONOOR DIFLUOROPHOSPHORIC ACID

    DOEpatents

    Johnson, R.; Horn, F.L.; Strickland, G.

    1963-05-01

    A method of dissolving and separating uranium from a uranium matrix fuel element by dissolving the uraniumcontaining matrix in monofluorophosphoric acid and/or difluorophosphoric acid at temperatures ranging from 150 to 275 un. Concent 85% C, thereafter neutralizing the solution to precipitate uranium solids, and converting the solids to uranium hexafluoride by treatment with a halogen trifluoride is presented. (AEC)

  10. 40 CFR 414.110 - Applicability; description of the subcategory of indirect discharge point sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Applicability; description of the subcategory of indirect discharge point sources. 414.110 Section 414.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND...

  11. 40 CFR 414.110 - Applicability; description of the subcategory of indirect discharge point sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Applicability; description of the subcategory of indirect discharge point sources. 414.110 Section 414.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND...

  12. 40 CFR 414.110 - Applicability; description of the subcategory of indirect discharge point sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the subcategory of indirect discharge point sources. 414.110 Section 414.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND...

  13. 40 CFR 414.110 - Applicability; description of the subcategory of indirect discharge point sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Applicability; description of the subcategory of indirect discharge point sources. 414.110 Section 414.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND...

  14. 40 CFR 414.110 - Applicability; description of the subcategory of indirect discharge point sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Applicability; description of the subcategory of indirect discharge point sources. 414.110 Section 414.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND...

  15. Minding the MeV gap: The indirect detection of low mass dark matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boddy, Kimberly K.; Kumar, Jason, E-mail: jkumar@hawaii.edu

    2016-06-21

    We consider the prospects for the indirect detection of low mass dark matter which couples dominantly to quarks. If the center of mass energy is below about 280 MeV, the kinematically allowed final states will be dominated by photons and neutral pions, producing striking signatures at gamma ray telescopes. In fact, an array of new instruments have been proposed, which would greatly improve sensitivity to photons in this energy range. We find that planned instruments can improve on current sensitivity to dark matter models of this type by up to a few orders of magnitude.

  16. Fast calcium transients translate the distribution and conduction of neural activity in different regions of a single sensory neuron.

    PubMed

    Purali, Nuhan

    2017-09-01

    In the present study, cytosolic calcium concentration changes were recorded in response to various forms of excitations, using the fluorescent calcium indicator dye OG-BAPTA1 together with the current or voltage clamp methods in stretch receptor neurons of crayfish. A single action potential evoked a rise in the resting calcium level in the axon and axonal hillock, whereas an impulse train or a large saturating current injection would be required to evoke an equivalent response in the dendrite region. Under voltage clamp conditions, amplitude differences between axon and dendrite responses vanished completely. The fast activation time and the modulation of the response by extracellular calcium concentration changes indicated that the evoked calcium transients might be mediated by calcium entry into the cytosol through a voltage-gated calcium channel. The decay of the responses was slow and sensitive to extracellular sodium and calcium concentrations as well as exposure to 1-10 mM NiCl 2 and 10-500 µM lanthanum. Thus, a sodium calcium exchanger and a calcium ATPase might be responsible for calcium extrusion from the cytosol. Present results indicate that the calcium indicator OG-BAPTA1 might be an efficient but indirect way of monitoring regional membrane potential differences in a single neuron.

  17. Determination of rheogenic ion transport in rat proximal colon in vivo.

    PubMed

    Haag, K; Lübcke, R; Knauf, H; Berger, E; Gerok, W

    1985-01-01

    A direct clamping technique is demonstrated, which allows monitoring of rapid changes of the short-circuit current (Isc) and the specific transepithelial resistance (Rm) as well as measurement of ion fluxes under short-circuit conditions in vivo. Due to the cylindrical symmetry of the colon the intraluminal electrode was devised as a centrally fixed silver rod, by which radial current injection was achieved. The geometrical arrangement of the electrodes guaranteed zero potential difference (PD) along the whole axis of the colon segment. The Isc was determined to 3.3 +/- 0.7 mueq h-1 cm-2 and Rm equal to 121 +/- 5 omega cm2. These data obtained by direct short-circuiting agree well with our earlier Rm and Isc data based on cable analysis, where the Isc was calculated from the open-circuit PD and Rm. This is considered as evidence for the reliability of the two independent in vivo techniques. Their validity was confirmed by the expected effects of drugs acting on rheogenic ion transport. Both the indirect (via Rm) as well as the direct Isc determination may be used alternatively as required; one may serve to match the other. For larger tubular structures like the rat colon the direct clamping should be preferred as the standard procedure for the Isc determination in vivo.

  18. Microglial Morphology and Dynamic Behavior Is Regulated by Ionotropic Glutamatergic and GABAergic Neurotransmission

    PubMed Central

    Fontainhas, Aurora M.; Wang, Minhua; Liang, Katharine J.; Chen, Shan; Mettu, Pradeep; Damani, Mausam; Fariss, Robert N.; Li, Wei; Wong, Wai T.

    2011-01-01

    Purpose Microglia represent the primary resident immune cells in the CNS, and have been implicated in the pathology of neurodegenerative diseases. Under basal or “resting” conditions, microglia possess ramified morphologies and exhibit dynamic surveying movements in their processes. Despite the prominence of this phenomenon, the function and regulation of microglial morphology and dynamic behavior are incompletely understood. We investigate here whether and how neurotransmission regulates “resting” microglial morphology and behavior. Methods We employed an ex vivo mouse retinal explant system in which endogenous neurotransmission and dynamic microglial behavior are present. We utilized live-cell time-lapse confocal imaging to study the morphology and behavior of GFP-labeled retinal microglia in response to neurotransmitter agonists and antagonists. Patch clamp electrophysiology and immunohistochemical localization of glutamate receptors were also used to investigate direct-versus-indirect effects of neurotransmission by microglia. Results Retinal microglial morphology and dynamic behavior were not cell-autonomously regulated but are instead modulated by endogenous neurotransmission. Morphological parameters and process motility were differentially regulated by different modes of neurotransmission and were increased by ionotropic glutamatergic neurotransmission and decreased by ionotropic GABAergic neurotransmission. These neurotransmitter influences on retinal microglia were however unlikely to be directly mediated; local applications of neurotransmitters were unable to elicit electrical responses on microglia patch-clamp recordings and ionotropic glutamatergic receptors were not located on microglial cell bodies or processes by immunofluorescent labeling. Instead, these influences were mediated indirectly via extracellular ATP, released in response to glutamatergic neurotransmission through probenecid-sensitive pannexin hemichannels. Conclusions Our results demonstrate that neurotransmission plays an endogenous role in regulating the morphology and behavior of “resting” microglia in the retina. These findings illustrate a mode of constitutive signaling between the neural and immune compartments of the CNS through which immune cells may be regulated in concert with levels of neural activity. PMID:21283568

  19. An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays

    PubMed Central

    Antonuk, Larry E.; Zhao, Qihua; El-Mohri, Youcef; Du, Hong; Wang, Yi; Street, Robert A.; Ho, Jackson; Weisfield, Richard; Yao, William

    2009-01-01

    Active matrix flat-panel imager (AMFPI) technology is being employed for an increasing variety of imaging applications. An important element in the adoption of this technology has been significant ongoing improvements in optical signal collection achieved through innovations in indirect detection array pixel design. Such improvements have a particularly beneficial effect on performance in applications involving low exposures and∕or high spatial frequencies, where detective quantum efficiency is strongly reduced due to the relatively high level of additive electronic noise compared to signal levels of AMFPI devices. In this article, an examination of various signal properties, as determined through measurements and calculations related to novel array designs, is reported in the context of the evolution of AMFPI pixel design. For these studies, dark, optical, and radiation signal measurements were performed on prototype imagers incorporating a variety of increasingly sophisticated array designs, with pixel pitches ranging from 75 to 127 μm. For each design, detailed measurements of fundamental pixel-level properties conducted under radiographic and fluoroscopic operating conditions are reported and the results are compared. A series of 127 μm pitch arrays employing discrete photodiodes culminated in a novel design providing an optical fill factor of ∼80% (thereby assuring improved x-ray sensitivity), and demonstrating low dark current, very low charge trapping and charge release, and a large range of linear signal response. In two of the designs having 75 and 90 μm pitches, a novel continuous photodiode structure was found to provide fill factors that approach the theoretical maximum of 100%. Both sets of novel designs achieved large fill factors by employing architectures in which some, or all of the photodiode structure was elevated above the plane of the pixel addressing transistor. Generally, enhancement of the fill factor in either discrete or continuous photodiode arrays was observed to result in no degradation in MTF due to charge sharing between pixels. While the continuous designs exhibited relatively high levels of charge trapping and release, as well as shorter ranges of linearity, it is possible that these behaviors can be addressed through further refinements to pixel design. Both the continuous and the most recent discrete photodiode designs accommodate more sophisticated pixel circuitry than is present on conventional AMFPIs – such as a pixel clamp circuit, which is demonstrated to limit signal saturation under conditions corresponding to high exposures. It is anticipated that photodiode structures such as the ones reported in this study will enable the development of even more complex pixel circuitry, such as pixel-level amplifiers, that will lead to further significant improvements in imager performance. PMID:19673228

  20. Fundus photography with a smartphone in indirect ophthalmoscopy in dogs and cats.

    PubMed

    Kanemaki, Nobuyuki; Inaniwa, Mizuho; Terakado, Kunihiko; Kawarai, Shinpei; Ichikawa, Yoichiro

    2017-05-01

    To introduce a simple method for fundus photography of dogs and cats using a smartphone and indirect ophthalmoscopy lenses. Fundus photographs of dogs and cats with transparent ocular media were obtained with 15D, 20D, 28D, and 40D indirect lenses and an iPhone-6, in a dark room and after pharmacologic pupil dilation. The photographs were recorded as still images using a video application and a video-to-still image application. Two types of neutral density (ND) filters were used as required for reduction of the torch illumination power of the iPhone. The images obtained in this study were upside-down as a result of the optics used. A 180-degree rotation was used to show their natural anatomical orientation. The image field of view varied with the diopter strength of the indirect lens used. The 40-diopter lens offered the widest field. Still images obtained with a smartphone, and indirect lenses may be useful for client communication and teaching in small animal ophthalmology. © 2016 American College of Veterinary Ophthalmologists.

  1. Cationic peptides from peptic hydrolysates of rice endosperm protein exhibit antimicrobial, LPS-neutralizing, and angiogenic activities.

    PubMed

    Taniguchi, Masayuki; Kawabe, Junya; Toyoda, Ryu; Namae, Toshiki; Ochiai, Akihito; Saitoh, Eiichi; Tanaka, Takaaki

    2017-11-01

    In this study, we hydrolyzed rice endosperm protein (REP) with pepsin and generated 20 fractions containing multifunctional cationic peptides with varying isoelectric point (pI) values using ampholyte-free isoelectric focusing (autofocusing). Subsequently, we determined antimicrobial activities of each fraction against the pathogens Prophyromonas gingivalis, Propionibacterium acnes, Streptocossus mutans, and Candida albicans. Fractions 18, 19, and 20 had pI values greater than 12 and exhibited antimicrobial activity against P. gingivalis, P. acnes, and C. albicans, but not against S. mutans. In further experiments, we purified and identified cationic peptides from fractions 18, 19, and 20 using reversed-phase high-performance liquid chromatography and matrix-assisted laser/desorption ionization-time-of-flight mass spectroscopy. We also chemically synthesized five identified peptides (RSVSKSR, RRVIEPR, ERFQPMFRRPG, RVRQNIDNPNRADTYNPRAG, and VVRRVIEPRGLL) with pI values greater than 10.5 and evaluated antimicrobial, lipopolysaccharide (LPS)-neutralizing, and angiogenic activities. Among these synthetic peptides, only VVRRVIEPRGLL exhibited antimicrobial activity against P. gingivalis, with an IC 50 value of 87μM. However, all five cationic peptides exhibited LPS-neutralizing and angiogenic activities with little or no hemolytic activity against mammalian red blood cells at functional concentrations. These present data show dual or multiple functions of the five identified cationic peptides with little or no hemolytic activity. Therefore, fractions containing cationic peptides from REP hydrolysates have the potential to be used as dietary supplements and functional ingredients in food products. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Detection of Zaire ebolavirus in swine: Assay development and optimization.

    PubMed

    Pickering, B S; Collignon, B; Smith, G; Marszal, P; Kobinger, G; Weingartl, H M

    2018-02-01

    Ebolaviruses (family Filoviridae, order Mononegavirales) cause often fatal, haemorrhagic fever in primates including humans. Pigs have been identified as a species susceptible to Reston ebolavirus (RESTV) infection, with indicated transmission to humans in the Philippines; however, their role during Ebola outbreaks in Africa needs to be clarified. To perform surveillance studies, detection of ebolavirus requires a prerequisite validation of viral RNA and antibody detection methods in swine samples. These diagnostic tests also need to be suitable for deployment to low-level containment laboratories. In this study, we developed a set of tests for detection of antibodies against Zaire ebolavirus (EBOV) in swine. Recombinant EBOV nucleoprotein was produced using a baculovirus expression system for indirect ELISA development. Evaluation of this assay was performed using laboratory and field samples, achieving a diagnostic specificity of 99%. Importantly, the indirect ELISA was able to detect antibodies to EBOV at 7 dpi, 3 days earlier than virus neutralization tests (VNT). The format of the VNT in this work was modified to a microtitre plaque reduction neutralization assay (miPRNT) complemented with immunostaining to provide a more rapid and highly specific assay. Finally, a confirmatory immunoblot assay was generated to supplement the indirect ELISA results. © 2017 Her Majesty the Queen in Right of Canada Reproduced with the permission of the Minister of Health and Agriculture, Canadian Food Inspection Agency.

  3. Baseline Design Compliance Matrix for the Rotary Mode Core Sampling System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LECHELT, J.A.

    2000-10-17

    The purpose of the design compliance matrix (DCM) is to provide a single-source document of all design requirements associated with the fifteen subsystems that make up the rotary mode core sampling (RMCS) system. It is intended to be the baseline requirement document for the RMCS system and to be used in governing all future design and design verification activities associated with it. This document is the DCM for the RMCS system used on Hanford single-shell radioactive waste storage tanks. This includes the Exhauster System, Rotary Mode Core Sample Trucks, Universal Sampling System, Diesel Generator System, Distribution Trailer, X-Ray Cart System,more » Breathing Air Compressor, Nitrogen Supply Trailer, Casks and Cask Truck, Service Trailer, Core Sampling Riser Equipment, Core Sampling Support Trucks, Foot Clamp, Ramps and Platforms and Purged Camera System. Excluded items are tools such as light plants and light stands. Other items such as the breather inlet filter are covered by a different design baseline. In this case, the inlet breather filter is covered by the Tank Farms Design Compliance Matrix.« less

  4. Open ended tubing cutters

    NASA Technical Reports Server (NTRS)

    Girala, A. S. (Inventor)

    1981-01-01

    A self clamping cutting tool which includes a handle attached to a C-shaped housing is described. Rotatably mounted within the housing is a C-shaped tool body carrying a set of clamping rolls, two support rolls, and an edged cutting roll (64). The support rolls are disposed to one side of the axis of a pipe and the cutting roll is disposed to the other side of a pipe axis so that these rolls contact a pipe at three circumferential points. Cutter advancing apparatus advance the cutting roll toward the support rollers. The support rolls and cutting roll are rotatable independently of the C-shaped housing. A one way ratchet mechanism disposed between the C-shaped housing and the C-shaped tool body permits operation by movement in one rotational direction about the pipe axis.

  5. Corrosion of dental aluminium bronze in neutral saline and saline lactic acid.

    PubMed

    Tibballs, J E; Erimescu, Raluca

    2006-09-01

    To compare the corrosion behaviours of two aluminium bronze, dental casting alloys during a standard immersion test and for immersion in neutral saline. Cast specimens of aluminium bronzes with 1.4 wt% Fe (G) and 4 wt% Fe (N) were subject to progressively longer periods (up to in total 7 days) immersed in 0.1 M saline, 0.1 M lactic acid solutions and examined by scanning electron microscopy with EDX analysis. Immersion in 0.1M neutral saline was for 7 days. In the acidic solution, exposed interdendritic volumes in alloy N corroded completely away in 7 days with dissolution of Ni-enriched precipitate species as well as the copper-rich matrix. Alloy G begins to corrode more slowly but by a similar mechanism. The number density of an Fe-enriched species is insufficient to maintain a continuous galvanic potential to the copper matrix, and dissolution becomes imperceptible. In neutral saline solution, galvanic action alone caused pit-etching, without the dissolution of either precipitate species. The upper limit for the total dissolution of metallic ions in the standard immersion test can be set at 200 microg cm(-2). Aluminium bronze dental alloys can be expected to release both copper and nickel ions into an acidic oral environment.

  6. Physicochemical characterization of point defects in fluorine doped tin oxide films

    NASA Astrophysics Data System (ADS)

    Akkad, Fikry El; Joseph, Sudeep

    2012-07-01

    The physical and chemical properties of spray deposited FTO films are studied using FESEM, x-ray diffraction (XRD), x-ray photoelectron spectroscopy (XPS), electrical and optical measurements. The results of XRD measurements showed that the films are polycrystalline (grain size 20-50 nm) with Rutile structure and mixed preferred orientation along the (200) and (110) planes. An angular shift of the XRD peaks after F-doping is observed and interpreted as being due to the formation of substitutional fluorine defects (FO) in presence of high concentration of oxygen vacancies (VO) that are electrically neutral. The electrical neutrality of oxygen vacancies is supported by the observation that the electron concentration n is two orders of magnitude lower than the VO concentration calculated from chemical analyses using XPS measurements. It is shown that an agreement between XPS, XRD, and Hall effect results is possible provided that the degree of deviation from stoichiometry is calculated with the assumption that the major part of the bulk carbon content is involved in O-C bonds. High temperature thermal annealing is found to cause an increase in the FO concentration and a decrease in both n and VO concentrations with the increase of the annealing temperature. These results could be interpreted in terms of a high temperature chemical exchange reaction between the SnO2 matrix and a precipitated fluoride phase. In this reaction, fluorine is released to the matrix and Sn is trapped by the fluoride phase, thus creating substitutional fluorine FO and tin vacancy VSn defects. The enthalpy of this reaction is determined to be approximately 2.4 eV while the energy of formation of a VSn through the migration of SnSn host atom to the fluoride phase is approximately 0.45 eV.

  7. A fast indirect method to compute functions of genomic relationships concerning genotyped and ungenotyped individuals, for diversity management.

    PubMed

    Colleau, Jean-Jacques; Palhière, Isabelle; Rodríguez-Ramilo, Silvia T; Legarra, Andres

    2017-12-01

    Pedigree-based management of genetic diversity in populations, e.g., using optimal contributions, involves computation of the [Formula: see text] type yielding elements (relationships) or functions (usually averages) of relationship matrices. For pedigree-based relationships [Formula: see text], a very efficient method exists. When all the individuals of interest are genotyped, genomic management can be addressed using the genomic relationship matrix [Formula: see text]; however, to date, the computational problem of efficiently computing [Formula: see text] has not been well studied. When some individuals of interest are not genotyped, genomic management should consider the relationship matrix [Formula: see text] that combines genotyped and ungenotyped individuals; however, direct computation of [Formula: see text] is computationally very demanding, because construction of a possibly huge matrix is required. Our work presents efficient ways of computing [Formula: see text] and [Formula: see text], with applications on real data from dairy sheep and dairy goat breeding schemes. For genomic relationships, an efficient indirect computation with quadratic instead of cubic cost is [Formula: see text], where Z is a matrix relating animals to genotypes. For the relationship matrix [Formula: see text], we propose an indirect method based on the difference between vectors [Formula: see text], which involves computation of [Formula: see text] and of products such as [Formula: see text] and [Formula: see text], where [Formula: see text] is a working vector derived from [Formula: see text]. The latter computation is the most demanding but can be done using sparse Cholesky decompositions of matrix [Formula: see text], which allows handling very large genomic and pedigree data files. Studies based on simulations reported in the literature show that the trends of average relationships in [Formula: see text] and [Formula: see text] differ as genomic selection proceeds. When selection is based on genomic relationships but management is based on pedigree data, the true genetic diversity is overestimated. However, our tests on real data from sheep and goat obtained before genomic selection started do not show this. We present efficient methods to compute elements and statistics of the genomic relationships [Formula: see text] and of matrix [Formula: see text] that combines ungenotyped and genotyped individuals. These methods should be useful to monitor and handle genomic diversity.

  8. 40 CFR 417.30 - Applicability; description of the soap manufacturing by fatty acid neutralization subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manufacturing by fatty acid neutralization subcategory. 417.30 Section 417.30 Protection of Environment... POINT SOURCE CATEGORY Soap Manufacturing by Fatty Acid Neutralization Subcategory § 417.30 Applicability; description of the soap manufacturing by fatty acid neutralization subcategory. The provisions of this subpart...

  9. The association in a two-way contingency table through log odds ratio analysis: the case of Sarno river pollution.

    PubMed

    Camminatiello, Ida; D'Ambra, Antonello; Sarnacchiaro, Pasquale

    2014-01-01

    In this paper we are proposing a general framework for the analysis of the complete set of log Odds Ratios (ORs) generated by a two-way contingency table. Starting from the RC (M) association model and hypothesizing a Poisson distribution for the counts of the two-way contingency table we are obtaining the weighted Log Ratio Analysis that we are extending to the study of log ORs. Particularly we are obtaining an indirect representation of the log ORs and some synthesis measures. Then for studying the matrix of log ORs we are performing a generalized Singular Value Decomposition that allows us to obtain a direct representation of log ORs. We also expect to get summary measures of association too. We have considered the matrix of complete set of ORs, because, it is linked to the two-way contingency table in terms of variance and it allows us to represent all the ORs on a factorial plan. Finally, a two-way contingency table, which crosses pollution of the Sarno river and sampling points, is to be analyzed to illustrate the proposed framework.

  10. A New Individually Addressable Micro-LED Array for Photogenetic Neural Stimulation.

    PubMed

    McGovern, B; Berlinguer Palmini, R; Grossman, N; Drakakis, E; Poher, V; Neil, M A A; Degenaar, P

    2010-12-01

    Here, we demonstrate the use of a micro light emitting diode (LED) array as a powerful tool for complex spatiotemporal control of photosensitized neurons. The array can generate arbitrary, 2-D, excitation patterns with millisecond and micrometer resolution. In particular, we describe an active matrix control address system to allow simultaneous control of 256 individual micro LEDs. We present the system optically integrated into a microscope environment and patch clamp electrophysiology. The results show that the emitters have sufficient radiance at the required wavelength to stimulate neurons expressing channelrhodopsin-2 (ChR2).

  11. Digital force-feedback for protein unfolding experiments using atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Bippes, Christian A.; Janovjak, Harald; Kedrov, Alexej; Muller, Daniel J.

    2007-01-01

    Since its invention in the 1990s single-molecule force spectroscopy has been increasingly applied to study protein (un-)folding, cell adhesion, and ligand-receptor interactions. In most force spectroscopy studies, the cantilever of an atomic force microscope (AFM) is separated from a surface at a constant velocity, thus applying an increasing force to folded bio-molecules or bio-molecular bonds. Recently, Fernandez and co-workers introduced the so-called force-clamp technique. Single proteins were subjected to a defined constant force allowing their life times and life time distributions to be directly measured. Up to now, the force-clamping was performed by analogue PID controllers, which require complex additional hardware and might make it difficult to combine the force-feedback with other modes such as constant velocity. These points may be limiting the applicability and versatility of this technique. Here we present a simple, fast, and all-digital (software-based) PID controller that yields response times of a few milliseconds in combination with a commercial AFM. We demonstrate the performance of our feedback loop by force-clamp unfolding of single Ig27 domains of titin and the membrane proteins bacteriorhodopsin (BR) and the sodium/proton antiporter NhaA.

  12. Neutral face classification using personalized appearance models for fast and robust emotion detection.

    PubMed

    Chiranjeevi, Pojala; Gopalakrishnan, Viswanath; Moogi, Pratibha

    2015-09-01

    Facial expression recognition is one of the open problems in computer vision. Robust neutral face recognition in real time is a major challenge for various supervised learning-based facial expression recognition methods. This is due to the fact that supervised methods cannot accommodate all appearance variability across the faces with respect to race, pose, lighting, facial biases, and so on, in the limited amount of training data. Moreover, processing each and every frame to classify emotions is not required, as user stays neutral for majority of the time in usual applications like video chat or photo album/web browsing. Detecting neutral state at an early stage, thereby bypassing those frames from emotion classification would save the computational power. In this paper, we propose a light-weight neutral versus emotion classification engine, which acts as a pre-processer to the traditional supervised emotion classification approaches. It dynamically learns neutral appearance at key emotion (KE) points using a statistical texture model, constructed by a set of reference neutral frames for each user. The proposed method is made robust to various types of user head motions by accounting for affine distortions based on a statistical texture model. Robustness to dynamic shift of KE points is achieved by evaluating the similarities on a subset of neighborhood patches around each KE point using the prior information regarding the directionality of specific facial action units acting on the respective KE point. The proposed method, as a result, improves emotion recognition (ER) accuracy and simultaneously reduces computational complexity of the ER system, as validated on multiple databases.

  13. Harmonic elastic inclusions in the presence of point moment

    NASA Astrophysics Data System (ADS)

    Wang, Xu; Schiavone, Peter

    2017-12-01

    We employ conformal mapping techniques to design harmonic elastic inclusions when the surrounding matrix is simultaneously subjected to remote uniform stresses and a point moment located at an arbitrary position in the matrix. Our analysis indicates that the uniform and hydrostatic stress field inside the inclusion as well as the constant hoop stress along the entire inclusion-matrix interface (on the matrix side) are independent of the action of the point moment. In contrast, the non-elliptical shape of the harmonic inclusion depends on both the remote uniform stresses and the point moment.

  14. Theoretical and testing performance of an innovative indirect evaporative chiller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Yi; Xie, Xiaoyun

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirectmore » evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller successfully satisfy the indoor air conditioning load for the demo building. The indirect evaporative chiller has a potentially wide application in dry regions, especially for large scale commercial buildings. Finally, this paper presented the geographic regions suitable for the technology worldwide. (author)« less

  15. 77 FR 24709 - Information Collections Being Reviewed by the Federal Communications Commission Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-25

    ... direct method of power determination due to technical reasons, the indirect method of determining antenna... antenna input power by the indirect method must determine the value F (efficiency factor) applicable to... antenna system field monitoring point, when the point itself is not changed. (2) A change in the type of...

  16. Thermal comfort in naturally ventilated buildings in Maceio, Brazil

    NASA Astrophysics Data System (ADS)

    Djamila, Harimi

    2017-11-01

    This article presents the results from thermal comfort survey carried out in classrooms over two different seasons in Maceio, Brazil. The secondary data were collected from thermal comfort field study conducted in naturally ventilated classrooms. Objective and subjective parameters were explored to evaluate thermal comfort conditions. The potential effect of air movement on subjects' vote under neutrality was evaluated. Overall, the indoor climate of the surveyed location was classified warm and humid. Conflicting results were depicted when analyzing the effect of air movements on subjects' vote. The mean air temperature for subjects feeling hot was found to be lower than those feeling warm. A reasonable approach to tackle these two unpredictable results was suggested. Correlation matrix between selected thermal comfort variables was developed. Globe temperature recorded the highest correlation with subjects' response on ASHRAE seven-point scale. The correlation was significant at the 0.01 level. On the other hand, the correlation between air movement and subjects' response on ASHRAE seven-point scale was weak but significant. Further field studies on the current topic were recommended.

  17. Electron energy distributions measured during electron beam/plasma interactions. [in E region

    NASA Technical Reports Server (NTRS)

    Jost, R. J.; Anderson, H. R.; Mcgarity, J. O.

    1980-01-01

    In the large vacuum facility at the NASA-Johnson Space Center an electron beam was projected 20 m parallel to B from a gun with variable accelerating potential (1.0 to 2.5 kV) to an aluminum target. The ionospheric neutral pressure and field were approximated. Beam electron energy distributions were measured directly using an electrostatic deflection analyzer and indirectly with a detector that responded to the X-rays produced by electron impact on the target. At low currents the distribution is sharply peaked at the acceleration potential. At high currents a beam plasma discharge occurs and electrons are redistributed in energy so that the former energy peak broadens to 10-15 percent FWHM with a strongly enhanced low energy tail. At the 10% of maximum point the energy spectrum ranges from less than 1/2 to 1.2 times the gun energy. The effect is qualitatively the same at all pitch angles and locations sampled.

  18. Impact of Renal Hilar Control on Outcomes of Robotic Partial Nephrectomy: Systematic Review and Cumulative Meta-analysis.

    PubMed

    Cacciamani, Giovanni E; Medina, Luis G; Gill, Tania S; Mendelsohn, Alec; Husain, Fatima; Bhardwaj, Lokesh; Artibani, Walter; Sotelo, Renè; Gill, Inderbir S

    2018-02-05

    During robotic partial nephrectomy (RPN), various techniques of hilar control have been described, including on-clamp, early unclamping, selective/super-selective clamping, and completely-unclamped RPN. To evaluate the impact of various hilar control techniques on perioperative, functional, and oncological outcomes of RPN for tumors. We conducted a systematic literature review and meta-analysis of all comparative studies on various hilar control techniques during RPN using PubMed, Scopus, and Web of Science according to the Preferred Reporting Items for Systematic Review and Meta-analysis statement, and Methods and Guide for Effectiveness and Comparative Effectiveness Review of the Agency for Healthcare Research and Quality. Cumulative meta-analysis of comparative studies was conducted using Review Manager 5.3. Of 987 RPN publications in the literature, 19 qualified for this analysis. Comparison of off-clamp versus on-clamp RPN (n=9), selective clamping versus on-clamp RPN (n=3), super selective clamping versus on-clamp RPN (n=5), and early unclamped versus on-clamp (n=3) were reported. Patients undergoing RPN using off-clamp, selective/super selective, or early unclamp techniques had higher estimated blood loss compared with on-clamp RPN (weight mean difference [WMD]: 47.83, p=0.000, WMD: 41.06, p=0.02, and WMD: 37.50, p=0.47); however, this did not seem clinically relevant, since transfusion rates were similar (odds ratio [OR]: 0.98, p=0.95, OR: 0.72, p=0.7, and OR: 1.36, p=0.33, respectively). All groups appeared similar with regards to hospital stay, transfusions, overall and major complications, and positive cancer margin rates. Short- and long-term renal functional outcomes appeared superior in the off-clamp and super selective clamp groups compared with the on-clamp RPN cohort. Off-clamp, selective/super selective clamp, and early unclamp hilar control techniques are safe and feasible approaches for RPN surgery, with similar perioperative and oncological outcomes compared with on-clamp RPN. Minimizing global renal ischemia may provide superior renal function preservation. However, higher quality data are necessary for definitive conclusions in this regard. The objective of partial nephrectomy is to treat the cancer while maximizing renal function preservation. Clamping the main vessels is done primarily to reduce the blood loss during partial nephrectomy; however, vascular clamping can compromise kidney function. In order to avoid clamping, various techniques have been described. Our analysis showed that techniques that avoid main renal artery clamping during RPN are associated with better renal function preservation, yet deliver non-inferior perioperative and oncological outcomes as compared with robotic partial nephrectomy procedures that clamp the main vessels. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  19. The effects of racial stressors and hostility on cardiovascular reactivity in African American and Caucasian men.

    PubMed

    Fang, C Y; Myers, H F

    2001-01-01

    This study examined the effects of race-related stressors and hostility on cardiovascular reactivity in 31 African American and 31 Caucasian men. Participants viewed 3 film excerpts that depicted neutral, anger-provoking (but race-neutral), and racist situations. Participants exhibited significantly greater diastolic blood pressure reactivity to anger-provoking and racist stimuli compared with neutral stimuli. In addition, high hostility was associated with higher recovery systolic and diastolic blood pressure levels after exposure to the films. Although the results failed to confirm previous reports of greater reactivity to racism in African Americans, the findings suggest that diastolic blood pressure levels may remain elevated after exposure to racist stimuli. These results indicate that even indirect exposure to interpersonal conflict elicits significant reactivity, which can persist after exposure to the stressor, especially among high-hostile men.

  20. Quantum field-theoretical description of neutrino and neutral kaon oscillations

    NASA Astrophysics Data System (ADS)

    Volobuev, Igor P.

    2018-05-01

    It is shown that the neutrino and neutral kaon oscillation processes can be consistently described in quantum field theory using only plane waves of the mass eigenstates of neutrinos and neutral kaons. To this end, the standard perturbative S-matrix formalism is modified so that it can be used for calculating the amplitudes of the processes passing at finite distances and finite time intervals. The distance-dependent and time-dependent parts of the amplitudes of the neutrino and neutral kaon oscillation processes are calculated and the results turn out to be in accordance with those of the standard quantum mechanical description of these processes based on the notion of neutrino flavor states and neutral kaon states with definite strangeness. However, the physical picture of the phenomena changes radically: now, there are no oscillations of flavor or definite strangeness states, but, instead of it, there is interference of amplitudes due to different virtual mass eigenstates.

  1. Clamp usable as jig and lifting clamp

    DOEpatents

    Tsuyama, Yoshizo

    1976-01-01

    There is provided a clamp which is well suited for use as a lifting clamp for lifting and moving materials of assembly in a shipyard, etc. and as a pulling jig in welding and other operations. The clamp comprises a clamp body including a shackle for engagement with a pulling device and a slot for receiving an article, and a pair of jaws provided on the leg portions of the clamp body on the opposite sides of the slot to grip the article in the slot, one of said jaws consisting of a screw rod and the other jaw consisting of a swivel jaw with a spherical surface, whereby when the article clamped in the slot by the pair of jaws tends to slide in any direction with respect to the clamp body, the article is more positively gripped by the pair of jaws.

  2. Cable clamp bolt fixture facilitates assembly in close quarters

    NASA Technical Reports Server (NTRS)

    Sunderland, G. H.

    1967-01-01

    Cable clamp bolt holding fixture facilitates forming of electrical cable runs in limited equipment space. The fixture engages the threads of the short clamp bolt through the clamp and maintains tension against clamp tendency to open while the operator installs the nut without difficulty.

  3. Split-tapered joint clamping device

    DOEpatents

    Olsen, Max J.; Schwartz, Jr., John F.

    1988-01-01

    This invention relates to a clamping device for removably attaching a tool element to a bracket element wherein a bracket element is disposed in a groove in the tool and a clamping member is disposed in said groove and in engagement with a clamping face of the bracket and a wall of the groove and with the clamping member having pivot means engaging the bracket and about which the clamping member rotates.

  4. Stoichiometry and pH dependence of the rabbit proton-dependent oligopeptide transporter PepT1.

    PubMed

    Steel, A; Nussberger, S; Romero, M F; Boron, W F; Boyd, C A; Hediger, M A

    1997-02-01

    1. The intestinal H(+)-coupled peptide transporter PepT1, displays a broad substrate specificity and accepts most charged and neutral di- and tripeptides. To study the proton-to-peptide stoichiometry and the dependence of the kinetic parameters on extracellular pH (pHo), rabbit PepT1 was expressed in Xenopus laevis oocytes and used for uptake studies of radiolabelled neutral and charged dipeptides, voltage-clamp analysis and intracellular pH measurements. 2. PepT1 did not display the substrate-gated anion conductances that have been found to be characteristic of members of the Na(+)- and H(+)-coupled high-affinity glutamate transporter family. In conjunction with previous data on the ion dependence of PepT1, it can therefore be concluded that peptide-evoked charge fluxes of PepT1 are entirely due to H+ movement. 3. Neutral, acidic and basic dipeptides induced intracellular acidification. The rate of acidification, the initial rates of the uptake of radiolabelled peptides and the associated charge fluxes gave proton-substrate coupling ratios of 1:1, 2:1 and 1:1 for neutral, acidic and basic dipeptides, respectively. 4. Maximal transport of the neutral and charged dipeptides Gly-Leu, Gly-Glu, Gly-Lys and Ala-Lys occurred at pHo 5.5, 5.2, 6.2 and 5.8, respectively. The Imax values were relatively pHo independent but the apparent affinity (Km(app) values for these peptides were shown to be highly pHo dependent. 5. Our data show that at physiological pH (pHo 5.5-6.0) PepT1 prefers neutral and acidic peptides. The shift in transport maximum for the acidic peptide Gly-Glu to a lower pH value suggests that acidic dipeptides are transported in the protonated form. The shift in the transport maxima of the basic dipeptides to higher pH values may involve titration of a side-chain on the transporter molecule (e.g. protonation of a histidine group). These considerations have led us to propose a model for coupled transport of neutral, acidic and basic dipeptides.

  5. Effect of complete hilar versus only renal artery clamping on renal histomorphology following ischemia/reperfusion injury in an experimental model.

    PubMed

    Umul, M; Cal, A C; Turna, B; Oktem, G; Aydın, H H

    2016-01-01

    To evaluate the effect of temporary complete hilar versus only renal artery clamping with different duration of warm ischemia on renal functions, and possibly identify a "safe" clamping type and duration of renal ischemia. Fifty male rabbits have been incorporated to study. Rabbits were subjected to ischemia/reperfusion injury by temporary vascular clamping. Reagents were randomized to 3 experimental groups (only renal artery clamping, complete hilar clamping, sham surgery) and sub-groups were determined according to different clamping times (30 and 60 minutes). Median laparotomy and left renal hilus dissection were performed to sham group. Only artery or complete hilar clamping was performed for 30 or 60 minutes by microvascular bulldog clamps to other reagents. Rabbits were sacrificed 10 days after primary surgery and left nephrectomy performed. Nephrectomy materials were evaluated for the level of nitric-oxide synthase (NOS) immunoreactivity, malondialdehyde (MDA) level and superoxide dismutase (SOD) activity and an electron microscopic examination was performed. NOS immunoreactivity was correlated with the temporary clamping time. We also observed that complete hilar vascular clamping entails an increase on NOS immunoreactivity. MDA levels were similar for all experimental surgery groups (p = 0.42). The SOD activity was decreased among all subgroups compared with sham surgery. But the significant decrease occurred in 30 minutes only artery and 30 minutes complete hilar clamping groups in proportion to sham surgery (p = 0.026 and p = 0.019, respectively). This current study suggested that only renal artery clamping under 30 minutes is more appropriate during renal surgical procedures requiring temporary vascular clamping.

  6. Infrared Spectroscopy of Matrix-Isolated Neutral and Ionized Anthracoronene in Argon.

    PubMed

    de Barros, A L F; Mattioda, A L; Korsmeyer, J M; Ricca, A

    2018-03-08

    The matrix-isolated mid-IR (MIR) spectrum of neutral and ionized anthracoronene (C 36 H 18 , AnthCor) in argon has been measured experimentally, compared to the spectrum of its parent molecules, coronene and anthracene, and analyzed by comparison to a theoretical spectrum computed using density functional theory (DFT). The experimental and theoretical band positions generally agree within 0-10 cm -1 . Anthracoronene exhibits extremely intense cation and anion bands around 1330 and 1318 cm -1 . The intensity of these two bands approaches what is traditionally observed over the entire 1000-1600 cm -1 range for a typical PAH cation or anion. The matrix-isolated near-IR (NIR) through overlap region (OVR) spectrum of ionized AnthCor in argon has been reported for the first time and compared to the spectrum of its parent molecules, coronene and anthracene. The spectrum of AnthCor contains a very strong electronic transition around 6175 cm -1 , placing it outside the range of the electronic transitions typically observed for PAHs. Anthracoronene is one of the few PAHs studied to date which has exhibited the formation of anions upon UV photolysis.

  7. Nanophosphor composite scintillators comprising a polymer matrix

    DOEpatents

    Muenchausen, Ross Edward; Mckigney, Edward Allen; Gilbertson, Robert David

    2010-11-16

    An improved nanophosphor composite comprises surface modified nanophosphor particles in a solid matrix. The nanophosphor particle surface is modified with an organic ligand, or by covalently bonding a polymeric or polymeric precursor material. The surface modified nanophosphor particle is essentially charge neutral, thereby preventing agglomeration of the nanophosphor particles during formation of the composite material. The improved nanophosphor composite may be used in any conventional scintillator application, including in a radiation detector.

  8. Keeping memories at an arm's length: vantage point of trauma memories.

    PubMed

    Kenny, Lucy M; Bryant, Richard A

    2007-08-01

    This study investigated the relationship between memory vantage point and avoidance following trauma. Sixty trauma survivors with differing levels of avoidance were interviewed about the vantage point of their memory for trauma, a positive memory, and a neutral memory. Avoidant individuals were more likely to remember their trauma from an observer perspective than individuals with a lower level of avoidance. Avoidance did not influence vantage point for positive or neutral memories. These data support the proposal that adoption of the observer vantage point for trauma memories may serve an avoidant function for people affected by trauma.

  9. A setup for combined multiphoton laser scanning microscopic and multi-electrode patch clamp experiments on brain slices

    NASA Astrophysics Data System (ADS)

    Helm, P. Johannes; Reppen, Trond; Heggelund, Paul

    2009-02-01

    Multi Photon Laser Scanning Microscopy (MPLSM) appears today as one of the most powerful experimental tools in cellular neurophysiology, notably in studies of the functional dynamics of signal processing in single neurons. Simultaneous recording of fluorescence signals at high spatial and temporal resolution and electric signals by means of multi electrode patch clamp techniques have provided new paths for the systematic investigation of neuronal mechanisms. In particular, this approach has opened for direct studies of dendritic signal processing in neurons. We report about a setup optimized for simultaneous electrophysiological multi electrode patch clamp and multi photon laser scanning fluorescence microscopic experiments on brain slices. The microscopic system is based on a modified commercially available confocal scanning laser microscope (CLSM). From a technical and operational point of view, two developments are important: Firstly, in order to reduce the workload for the experimentalist, who in general is forced to concentrate on controlling the electrophysiological parameters during the recordings, a system of shutters has been installed together with dedicated electronic modules protecting the photo detectors against destructive light levels caused by erroneous opening or closing of microscopic light paths by the experimentalist. Secondly, the standard detection unit has been improved by installing the photomultiplier tubes (PMT) in a Peltier cooled thermal box shielding the detector from both room temperature and distortions caused by external electromagnetic fields. The electrophysiological system is based on an industrial standard multi patch clamp unit ergonomically arranged around the microscope stage. The electrophysiological and scanning processes can be time coordinated by standard trigger electronics.

  10. Automated Electrophysiology Makes the Pace for Cardiac Ion Channel Safety Screening

    PubMed Central

    Möller, Clemens; Witchel, Harry

    2011-01-01

    The field of automated patch-clamp electrophysiology has emerged from the tension between the pharmaceutical industry’s need for high-throughput compound screening versus its need to be conservative due to regulatory requirements. On the one hand, hERG channel screening was increasingly requested for new chemical entities, as the correlation between blockade of the ion channel coded by hERG and torsades de pointes cardiac arrhythmia gained increasing attention. On the other hand, manual patch-clamping, typically quoted as the “gold-standard” for understanding ion channel function and modulation, was far too slow (and, consequently, too expensive) for keeping pace with the numbers of compounds submitted for hERG channel investigations from pharmaceutical R&D departments. In consequence it became more common for some pharmaceutical companies to outsource safety pharmacological investigations, with a focus on hERG channel interactions. This outsourcing has allowed those pharmaceutical companies to build up operational flexibility and greater independence from internal resources, and allowed them to obtain access to the latest technological developments that emerged in automated patch-clamp electrophysiology – much of which arose in specialized biotech companies. Assays for nearly all major cardiac ion channels are now available by automated patch-clamping using heterologous expression systems, and recently, automated action potential recordings from stem-cell derived cardiomyocytes have been demonstrated. Today, most of the large pharmaceutical companies have acquired automated electrophysiology robots and have established various automated cardiac ion channel safety screening assays on these, in addition to outsourcing parts of their needs for safety screening. PMID:22131974

  11. Mixed H2/Hinfinity output-feedback control of second-order neutral systems with time-varying state and input delays.

    PubMed

    Karimi, Hamid Reza; Gao, Huijun

    2008-07-01

    A mixed H2/Hinfinity output-feedback control design methodology is presented in this paper for second-order neutral linear systems with time-varying state and input delays. Delay-dependent sufficient conditions for the design of a desired control are given in terms of linear matrix inequalities (LMIs). A controller, which guarantees asymptotic stability and a mixed H2/Hinfinity performance for the closed-loop system of the second-order neutral linear system, is then developed directly instead of coupling the model to a first-order neutral system. A Lyapunov-Krasovskii method underlies the LMI-based mixed H2/Hinfinity output-feedback control design using some free weighting matrices. The simulation results illustrate the effectiveness of the proposed methodology.

  12. Electronic Absorption Spectra of Neutral Perylene (C20H12), Terrylene (C30H16), and Quaterrylene (C40H20) and their Positive and Negative Ions: Ne Matrix-Isolation Spectroscopy and Time Dependent Density Functional Theory Calculations

    NASA Technical Reports Server (NTRS)

    Halasinski, Thomas M.; Weisman, Jennifer L.; Lee, Timothy J.; Salama, Farid; Head-Gordon, Martin; Kwak, Dochan (Technical Monitor)

    2002-01-01

    We present a full experimental and theoretical study of an interesting series of polycyclic aromatic hydrocarbons, the oligorylenes. The absorption spectra of perylene, terrylene and quaterrylene in neutral, cationic and anionic charge states are obtained by matrix-isolation spectroscopy in Ne. The experimental spectra are dominated by a bright state that red shifts with growing molecular size. Excitation energies and state symmetry assignments are supported by calculations using time dependent density functional theory methods. These calculations also provide new insight into the observed trends in oscillator strength and excitation energy for the bright states: the oscillator strength per unit mass of carbon increases along the series.

  13. Lifting clamp positively grips structural shapes

    NASA Technical Reports Server (NTRS)

    Reinhardt, E. C.

    1966-01-01

    Welded steel clamps securely grip structural shapes of various sizes for crane operations. The clamp has adjustable clamping jaws and screw-operated internal v-jaws and provides greater safety than hoisting slings presently used. The structural member can be rotated in any manner, angle, or direction without being released by the clamp.

  14. Observing heliospheric neutral atoms at 1 AU

    NASA Astrophysics Data System (ADS)

    Heerikhuisen, Jacob; Pogorelov, Nikolai; Florinski, Vladimir; Zank, Gary

    2006-09-01

    Although in situ observations of distant heliospheric plasma by the Voyagers has proven to be extremely enlightening, such point observations need to be complemented with global measurements taken remotely to obtain a complete picture of the heliosphere and local interstellar environment. Neutral atoms, with their contempt for magnetic fields, provide useful probes of the plasma that generated them. However, there will be a number of ambiguities in neutral atom readings that require a deeper understanding of the plasma processes generating neutral atoms, as well as the loss mechanisms on their flight to the observation point. We introduce a procedure for generating all-sky maps of energetic H-atoms, calculated directly in our Monte-Carlo neutral atom code. Results obtained for a self-consistent axisymmetric MHD-Boltzmann calculation, as well as several non-selfconsistent 3D sky maps, will be presented.

  15. DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishnaswami, Hariharan

    The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the convertersmore » combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.« less

  16. Selective Arterial Clamping Versus Hilar Clamping for Minimally Invasive Partial Nephrectomy.

    PubMed

    Yezdani, Mona; Yu, Sue-Jean; Lee, David I

    2016-05-01

    Partial nephrectomy has become an accepted treatment of cT1 renal masses as it provides improved long-term renal function compared to radical nephrectomy (Campbell et al. J Urol. 182:1271-9, 2009). Hilar clamping is utilized to help reduce bleeding and improve visibility during tumor resection. However, concern over risk of kidney injury with hilar clamping has led to new techniques to reduce length of warm ischemia time (WIT) during partial nephrectomy. These techniques have progressed over the years starting with early hilar unclamping, controlled hypotension during tumor resection, selective arterial clamping, minimal margin techniques, and off-clamp procedures. Selective arterial clamping has progressed significantly over the years. The main question is what are the exact short- and long-term renal effects from increasing clamp time. Moreover, does it make sense to perform these more time-consuming or more complex procedures if there is no long-term preservation of kidney function? More recent studies have shown no difference in renal function 6 months from surgery when selective arterial clamping or even hilar clamping is employed, although there is short-term improved decline in estimated glomerular filtration rate (eGFR) with selective clamping and off-clamp techniques (Komninos et al. BJU Int. 115:921-8, 2015; Shah et al. 117:293-9, 2015; Kallingal et al. BJU Int. doi: 10.1111/bju.13192, 2015). This paper reviews the progression of total hilar clamping to selective arterial clamping (SAC) and the possible difference its use makes on long-term renal function. SAC may be attempted based on surgeon's decision-making, but may be best used for more complex, larger, more central or hilar tumors and in patients who have renal insufficiency at baseline or a solitary kidney.

  17. Whole-Cell Electrical Activity Under Direct Mechanical Stimulus by AFM Cantilever Using Planar Patch Clamp Chip Approach

    PubMed Central

    Upadhye, Kalpesh V.; Candiello, Joseph E.; Davidson, Lance A.; Lin, Hai

    2011-01-01

    Patch clamp is a powerful tool for studying the properties of ion-channels and cellular membrane. In recent years, planar patch clamp chips have been fabricated from various materials including glass, quartz, silicon, silicon nitride, polydimethyl-siloxane (PDMS), and silicon dioxide. Planar patch clamps have made automation of patch clamp recordings possible. However, most planar patch clamp chips have limitations when used in combination with other techniques. Furthermore, the fabrication methods used are often expensive and require specialized equipments. An improved design as well as fabrication and characterization of a silicon-based planar patch clamp chip are described in this report. Fabrication involves true batch fabrication processes that can be performed in most common microfabrication facilities using well established MEMS techniques. Our planar patch clamp chips can form giga-ohm seals with the cell plasma membrane with success rate comparable to existing patch clamp techniques. The chip permits whole-cell voltage clamp recordings on variety of cell types including Chinese Hamster Ovary (CHO) cells and pheochromocytoma (PC12) cells, for times longer than most available patch clamp chips. When combined with a custom microfluidics chamber, we demonstrate that it is possible to perfuse the extra-cellular as well as intra-cellular buffers. The chamber design allows integration of planar patch clamp with atomic force microscope (AFM). Using our planar patch clamp chip and microfluidics chamber, we have recorded whole-cell mechanosensitive (MS) currents produced by directly stimulating human keratinocyte (HaCaT) cells using an AFM cantilever. Our results reveal the spatial distribution of MS ion channels and temporal details of the responses from MS channels. The results show that planar patch clamp chips have great potential for multi-parametric high throughput studies of ion channel proteins. PMID:22174731

  18. Exospheric Neutral Density at the Earth's subsolar magnetopause deduced from the XMM-Newton X-ray observations

    NASA Astrophysics Data System (ADS)

    Connor, H. K.; Carter, J. A.

    2017-12-01

    Soft X-rays can be emitted when highly charged solar wind ions and exospheric neutrals exchange electrons. Astrophysics missions, such as XMM-Newton and ROSAT X-ray telescopes, have found that such solar wind charge exchange happens at the Earth's exosphere. The Earth's magnetosphere can be imaged via soft X-rays in order to understand its interaction with solar wind. Consequently, two soft X-ray telescope missions (CuPID and SMILE) are scheduled to launch in 2019 and 2021. They will provide wide field-of-view soft X-ray images of the Earth's dayside magnetosphere. The imagers will track the location and movement of the cusps, magnetopause, and bow shock in response to solar wind variations. To support these missions, an understanding of exospheric neutral density profile is needed. The neutral density is one of the controlling factors of soft X-ray signals. Strong neutral density can help to obtain high-resolution and high-cadence of soft X-ray images. In this study, we estimate the exospheric neutral density at 10 RE subsolar point using XMM X-ray observations, Cluster plasma observations, and OpenGGCM global magnetosphere - ionosphere MHD model. XMM-Newton observes line-of-sight, narrow field-of-view, integrated soft X-ray emissions when it looks through the dayside magnetosphere. OpenGGCM reproduces soft X-ray signals seen by the XMM spacecraft, assuming exospheric neutral density as a function of the neutral density at the 10RE subsolar point and the radial distance. Cluster observations are used to confirm OpenGGCM plasma results. Finally, we deduce the neutral density at 10 RE subsolar point by adjusting the model results to the XMM-Newton soft X-ray observations.

  19. Measuring beta-cell function relative to insulin sensitivity in youth: Does the hyperglycemic clamp suffice?

    USDA-ARS?s Scientific Manuscript database

    To compare beta-cell function relative to insulin sensitivity, disposition index (DI), calculated from two clamps (2cDI, insulin sensitivity from the hyperinsulinemic-euglycemic clamp and first-phase insulin from the hyperglycemic clamp) with the DI calculated from the hyperglycemic clamp alone (hcD...

  20. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  1. A Test for Characterizing Delamination Migration in Carbon/Epoxy Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; Czabaj, Michael W.; O'Brien, Thomas K.

    2013-01-01

    A new test method is presented for the purpose of investigating migration of a delamination between neighboring ply interfaces in fiber-reinforced, polymer matrix tape laminates. The test is a single cantilever beam configuration consisting of a cross-ply laminate with a polytetrafluoroethylene insert implanted at the mid-plane and spanning part way along the length of the specimen. The insert is located between a 0- degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The specimen is clamped at both ends onto a rigid baseplate and is loaded on its upper surface via a piano hinge. Tests were conducted with the load-application point located on the intact portion of the specimen in order to initiate delamination growth onset followed by migration of the delamination to a neighboring 90/0 ply interface by kinking through the 90-degree ply stack. Varying this position was found to affect the distance relative to the load-application point at which migration initiated. In each specimen, migration initiated by a gradual transition of the delamination at the 0/90 interface into the 90-degree ply stack. In contrast, transition of the kinked crack into the 90/0 interface was sudden. Fractography of the specimens indicated that delamination prior to migration was generally mixed mode-I/II. Inspection of the kink surface revealed mode-I fracture. In general, use of this test allows for the observation of the growth of a delamination followed by migration of the delamination to another ply interface, and should thus provide a means for validating analyses aimed at simulating migration.

  2. Characterizing Delamination Migration in Carbon/Epoxy Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; Czabaj, Michael W.; Obrien, Thomas K.

    2012-01-01

    A new test method is presented for the purpose of investigating migration of a delamination between neighboring ply interfaces in fiber-reinforced, polymer matrix tape laminates. The test is a single cantilever beam configuration consisting of a cross-ply laminate with a polytetrafluoroethylene (PTFE) insert implanted at the mid-plane and spanning part way along the length of the specimen. The insert is located between a 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The specimen is clamped at both ends onto a rigid baseplate and is loaded on its upper surface via a piano hinge. Tests were conducted with the load-application point located on the intact portion of the specimen in order to initiate delamination growth onset followed by migration of the delamination to a neighboring 90/0 ply interface by kinking through the 90- degree ply stack. Varying this position was found to affect the distance relative to the load-application point at which migration initiated. In each specimen, migration initiated by a gradual transition of the delamination at the 0/90 interface into the 90- degree ply stack. In contrast, transition of the kinked crack into the 90/0 interface was sudden. Fractography of the specimens indicated that delamination prior to migration was generally mixed mode-I/II. Inspection of the kink surface revealed mode-I fracture. In general, use of this test allows for the observation of the growth of a delamination followed by migration of the delamination to another ply interface, and should thus provide a means for validating analyses aimed at simulating migration.

  3. Acoustooptic linear algebra processors - Architectures, algorithms, and applications

    NASA Technical Reports Server (NTRS)

    Casasent, D.

    1984-01-01

    Architectures, algorithms, and applications for systolic processors are described with attention to the realization of parallel algorithms on various optical systolic array processors. Systolic processors for matrices with special structure and matrices of general structure, and the realization of matrix-vector, matrix-matrix, and triple-matrix products and such architectures are described. Parallel algorithms for direct and indirect solutions to systems of linear algebraic equations and their implementation on optical systolic processors are detailed with attention to the pipelining and flow of data and operations. Parallel algorithms and their optical realization for LU and QR matrix decomposition are specifically detailed. These represent the fundamental operations necessary in the implementation of least squares, eigenvalue, and SVD solutions. Specific applications (e.g., the solution of partial differential equations, adaptive noise cancellation, and optimal control) are described to typify the use of matrix processors in modern advanced signal processing.

  4. Indirect addressing and load balancing for faster solution to Mandelbrot Set on SIMD architectures

    NASA Technical Reports Server (NTRS)

    Tomboulian, Sherryl

    1989-01-01

    SIMD computers with local indirect addressing allow programs to have queues and buffers, making certain kinds of problems much more efficient. Examined here are a class of problems characterized by computations on data points where the computation is identical, but the convergence rate is data dependent. Normally, in this situation, the algorithm time is governed by the maximum number of iterations required by each point. Using indirect addressing allows a processor to proceed to the next data point when it is done, reducing the overall number of iterations required to approach the mean convergence rate when a sufficiently large problem set is solved. Load balancing techniques can be applied for additional performance improvement. Simulations of this technique applied to solving Mandelbrot Sets indicate significant performance gains.

  5. Dyadic Green's function of a cluster of spheres.

    PubMed

    Moneda, Angela P; Chrissoulidis, Dimitrios P

    2007-11-01

    The electric dyadic Green's function (dGf) of a cluster of spheres is obtained by application of the superposition principle, dyadic algebra, and the indirect mode-matching method. The analysis results in a set of linear equations for the unknown, vector, wave amplitudes of the dGf; that set is solved by truncation and matrix inversion. The theory is exact in the sense that no simplifying assumptions are made in the analytical steps leading to the dGf, and it is general in the sense that any number, position, size and electrical properties can be considered for the spheres that cluster together. The point source can be anywhere, even within one of the spheres. Energy conservation, reciprocity, and other tests prove that this solution is correct. Numerical results are presented for an electric Hertz dipole radiating in the presence of an array of rexolite spheres, which manifests lensing and beam-forming capabilities.

  6. Approximate analytical solutions in the analysis of thin elastic plates

    NASA Astrophysics Data System (ADS)

    Goloskokov, Dmitriy P.; Matrosov, Alexander V.

    2018-05-01

    Two approaches to the construction of approximate analytical solutions for bending of a rectangular thin plate are presented: the superposition method based on the method of initial functions (MIF) and the one built using the Green's function in the form of orthogonal series. Comparison of two approaches is carried out by analyzing a square plate clamped along its contour. Behavior of the moment and the shear force in the neighborhood of the corner points is discussed. It is shown that both solutions give identical results at all points of the plate except for the neighborhoods of the corner points. There are differences in the values of bending moments and generalized shearing forces in the neighborhoods of the corner points.

  7. Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording

    PubMed Central

    Kolb, Ilya; Kodandaramaiah, Suhasa B.; Chubykin, Alexander A.; Yang, Aimei; Bear, Mark F.; Boyden, Edward S.; Forest, Craig R.

    2014-01-01

    Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput of patch clamping for single-ion channel and single-cell analyses. In this work, we have developed a custom patch-clamp amplifier microchip that can be fabricated using standard commercial silicon processes capable of performing both voltage- and current-clamp measurements. A key innovation is the use of nonlinear feedback elements in the voltage-clamp amplifier circuit to convert measured currents into logarithmically encoded voltages, thereby eliminating the need for large high-valued resistors, a factor that has limited previous attempts at integration. Benchtop characterization of the chip shows low levels of current noise [1.1 pA root mean square (rms) over 5 kHz] during voltage-clamp measurements and low levels of voltage noise (8.2 μV rms over 10 kHz) during current-clamp measurements. We demonstrate the ability of the chip to perform both current- and voltage-clamp measurement in vitro in HEK293FT cells and cultured neurons. We also demonstrate its ability to perform in vivo recordings as part of a robotic patch-clamping system. The performance of the patch-clamp amplifier microchip compares favorably with much larger commercial instrumentation, enabling benchtop commoditization, miniaturization, and scalable patch-clamp instrumentation. PMID:25429119

  8. Photovoltaic panel clamp

    DOEpatents

    Mittan, Margaret Birmingham [Oakland, CA; Miros, Robert H. J. [Fairfax, CA; Brown, Malcolm P [San Francisco, CA; Stancel, Robert [Loss Altos Hills, CA

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  9. Photovoltaic panel clamp

    DOEpatents

    Brown, Malcolm P.; Mittan, Margaret Birmingham; Miros, Robert H. J.; Stancel, Robert

    2013-03-19

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  10. Differential control of MMP and t-PA/PAI-1 expressions by sympathetic and renin-angiotensin systems in rat left ventricle.

    PubMed

    Dab, Houcine; Hachani, Rafik; Hodroj, Wassim; Sakly, Mohsen; Bricca, Giampiero; Kacem, Kamel

    2009-10-05

    In the present study, we tested the hypothesis that angiotensin II (Ang II) has both direct (via AT1 receptors) and indirect (via sympathostimulator pathway) actions on the synthesis and activity of the enzymes involved in the extracellular matrix degradation in vivo. For this purpose, sympathectomy and blockade of the Ang II receptor AT1 were performed alone or in combination in normotensive rats. The mRNA of the plasminogen activator (t-PA) and its inhibitor (PAI-1), the mRNA, protein and activity of the matrix metalloproteinases MMP-2 and MMP-9 were examined by Q-RT-PCR, immunoblotting and zymographic methods in the left ventricle. t-PA and PAI-1 mRNA were decreased after sympathectomy and remained unchanged after AT1 receptors blockade. mRNA was increased for t-PA and decreased by similar degree for PAI-1 after double treatment. MMPs mRNA and protein levels were decreased either after sympathectomy or AT1 receptors blockade and an additive effect was acquired after double treatment. MMPs activity was decreased by similar degree in the three treated groups. Deducted interpretations from our experimental approach suggest that Ang II inhibits directly (via AT1 receptors) and indirectly (via sympathostimulator pathway) t-PA mRNA synthesis. It seems unable to influence directly PAI-1 mRNA, but stimulates indirectly PAI-1 mRNA synthesis. Ang II stimulates directly (via AT1 receptors) and indirectly (via sympathostimulator pathway) MMPs synthesis at both transcriptional and protein levels. The enzymatic activity of MMPs does not seem to be influenced directly by Ang II but it could be stimulated indirectly (via sympathostimulator pathway).

  11. Influence of a peracetic acid-based immersion on indirect composite resin.

    PubMed

    Samuel, Susana Maria Werner; Fracaro, Gisele Baggio; Collares, Fabrício Mezzomo; Leitune, Vicente Castelo Branco; Campregher, Ulisses Bastos

    2011-06-01

    The aim of this study was to evaluate the influence of immersion in a 0.2% peracetic acid-based disinfectant on the three-point flexural strength, water sorption and water solubility of an indirect composite resin. Specimens were produced according to ISO 4049:2000 specifications and were divided in two groups: Control group, with no disinfection and Disinfected group, with three 10 min immersions in the peracetic acid intercalated with 10 min immersions in sterile distilled water. All evaluations were conducted in compliance with ISO specifications. Three-point flexural strength, water sorption and solubility of indirect composite resin before and after immersion showed no statistical significant differences (p > 0.05) and met ISO standard requirements. Immersion in peracetic acid solution showed no influence in indirect composite resin tested properties.

  12. The protective effect of Mucuna pruriens seeds against snake venom poisoning.

    PubMed

    Tan, Nget Hong; Fung, Shin Yee; Sim, Si Mui; Marinello, Enrico; Guerranti, Roberto; Aguiyi, John C

    2009-06-22

    The seed, leaf and root of Mucuna pruriens have been used in traditional medicine for treatments of various diseases. In Nigeria, the seed is used as oral prophylactics for snakebite. To study the protective effects of Mucuna pruriens seed extract against the lethalities of various snake venoms. Rats were pre-treated with Mucuna pruriens seed extract and challenged with various snake venoms. The effectiveness of anti-Mucuna pruriens (anti-MPE) antibody to neutralize the lethalities of snake venoms was investigated by in vitro neutralization. In rats, MPE pre-treatment conferred effective protection against lethality of Naja sputatrix venom and moderate protection against Calloselasma rhodostoma venom. Indirect ELISA and immunoblotting studies showed that there were extensive cross-reactions between anti-MPE IgG and venoms from many different genera of poisonous snakes, suggesting the involvement of immunological neutralization in the protective effect of MPE pre-treatment against snake venom poisoning. In vitro neutralization experiments showed that the anti-MPE antibodies effectively neutralized the lethalities of Asiatic cobra (Naja) venoms, but were not very effective against other venoms tested. The anti-MPE antibodies could be used in the antiserum therapy of Asiatic cobra (Naja) bites.

  13. A 5-day high-fat, high-calorie diet impairs insulin sensitivity in healthy, young South Asian men but not in Caucasian men.

    PubMed

    Bakker, Leontine E H; van Schinkel, Linda D; Guigas, Bruno; Streefland, Trea C M; Jonker, Jacqueline T; van Klinken, Jan B; van der Zon, Gerard C M; Lamb, Hildo J; Smit, Johannes W A; Pijl, Hanno; Meinders, A Edo; Jazet, Ingrid M

    2014-01-01

    South Asians (SAs) develop type 2 diabetes at a younger age and lower BMI compared with Caucasians (Cs). The underlying cause is still poorly understood but might result from an innate inability to adapt to the Westernized diet. This study aimed to compare the metabolic adaptation to a high-fat, high-calorie (HFHC) diet between both ethnicities. Twelve healthy, young lean male SAs and 12 matched Cs underwent a two-step hyperinsulinemic-euglycemic clamp with skeletal muscle biopsies and indirect calorimetry before and after a 5-day HFHC diet. Hepatic triglyceride content (HTG) and abdominal fat distribution were assessed using magnetic resonance imaging and spectroscopy. At baseline, SAs had higher insulin clamp levels than Cs, indicating reduced insulin clearance rate. Despite the higher insulin levels, endogenous glucose production was comparable between groups, suggesting lower hepatic insulin sensitivity in SAs. Furthermore, a 5-day HFHC diet decreased the insulin-stimulated (nonoxidative) glucose disposal rate only in SA. In skeletal muscle, no significant differences were found between groups in insulin/mammalian target of rapamycin signaling, metabolic gene expression, and mitochondrial respiratory chain content. Furthermore, no differences in (mobilization of) HTG and abdominal fat were detected. We conclude that HFHC feeding rapidly induces insulin resistance only in SAs. Thus, distinct adaptation to Western food may partly explain their propensity to develop type 2 diabetes.

  14. Effect of "preoperative" oral carbohydrate treatment on insulin action--a randomised cross-over unblinded study in healthy subjects.

    PubMed

    Svanfeldt, Monika; Thorell, Anders; Hausel, Jonatan; Soop, Mattias; Nygren, Jonas; Ljungqvist, Olle

    2005-10-01

    Preoperative intake of a clear carbohydrate-rich drink reduces insulin resistance after surgery. In this study, we evaluated whether this could be related to increased insulin sensitivity at the onset of surgery. Furthermore, we aimed to establish the optimal dose-regimen. Six healthy volunteers underwent hyperinsulinaemic (0.8 mU/kg/min), normoglycaemic (4.5 mmol/l) clamps and indirect calorimetry on four occasions in a crossover-randomised order; after overnight fasting (CC), after a single evening dose (800 ml) of the drink (LC), after a single morning dose (400 ml, CL) and after intake of the drink in the evening and in the morning before the clamp (LL). Data are presented as mean+/-SD. Statistical analysis was performed using the Student's t-test and ANOVA. Insulin sensitivity was higher in CL and LL (9.2+/-1.5 and 9.3+/-1.9 mg/kg/min, respectively) compared to CC and LC (6.1+/-1.6 and 6.6+/-1.9 mg/kg/min, P<0.01 vs. CL and LL). A carbohydrate-rich drink enhances insulin action 3 h later by approximately 50%. Enhanced insulin action to normal postprandial day-time level at the time of onset of anaesthesia or surgery is likely to, at least partly, explain the effects on postoperative insulin resistance.

  15. BMI, RQ, Diabetes, and Sex Affect the Relationships Between Amino Acids and Clamp Measures of Insulin Action in Humans

    PubMed Central

    Thalacker-Mercer, Anna E.; Ingram, Katherine H.; Guo, Fangjian; Ilkayeva, Olga; Newgard, Christopher B.; Garvey, W. Timothy

    2014-01-01

    Previous studies have used indirect measures of insulin sensitivity to link circulating amino acids with insulin resistance and identify potential biomarkers of diabetes risk. Using direct measures (i.e., hyperinsulinemic-euglycemic clamps), we examined the relationships between the metabolomic amino acid profile and insulin action (i.e., glucose disposal rate [GDR]). Relationships between GDR and serum amino acids were determined among insulin-sensitive, insulin-resistant, and type 2 diabetic (T2DM) individuals. In all subjects, glycine (Gly) had the strongest correlation with GDR (positive association), followed by leucine/isoleucine (Leu/Ile) (negative association). These relationships were dramatically influenced by BMI, the resting respiratory quotient (RQ), T2DM, and sex. Gly had a strong positive correlation with GDR regardless of BMI, RQ, or sex but became nonsignificant in T2DM. In contrast, Leu/Ile was negatively associated with GDR in nonobese and T2DM subjects. Increased resting fat metabolism (i.e., low RQ) and obesity were observed to independently promote and negate the association between Leu/Ile and insulin resistance, respectively. Additionally, the relationship between Leu/Ile and GDR was magnified in T2DM males. Future studies are needed to determine whether Gly has a mechanistic role in glucose homeostasis and whether dietary Gly enrichment may be an effective intervention in diseases characterized by insulin resistance. PMID:24130332

  16. Linear analysis near a steady-state of biochemical networks: control analysis, correlation metrics and circuit theory.

    PubMed

    Heuett, William J; Beard, Daniel A; Qian, Hong

    2008-05-15

    Several approaches, including metabolic control analysis (MCA), flux balance analysis (FBA), correlation metric construction (CMC), and biochemical circuit theory (BCT), have been developed for the quantitative analysis of complex biochemical networks. Here, we present a comprehensive theory of linear analysis for nonequilibrium steady-state (NESS) biochemical reaction networks that unites these disparate approaches in a common mathematical framework and thermodynamic basis. In this theory a number of relationships between key matrices are introduced: the matrix A obtained in the standard, linear-dynamic-stability analysis of the steady-state can be decomposed as A = SRT where R and S are directly related to the elasticity-coefficient matrix for the fluxes and chemical potentials in MCA, respectively; the control-coefficients for the fluxes and chemical potentials can be written in terms of RTBS and STBS respectively where matrix B is the inverse of A; the matrix S is precisely the stoichiometric matrix in FBA; and the matrix eAt plays a central role in CMC. One key finding that emerges from this analysis is that the well-known summation theorems in MCA take different forms depending on whether metabolic steady-state is maintained by flux injection or concentration clamping. We demonstrate that if rate-limiting steps exist in a biochemical pathway, they are the steps with smallest biochemical conductances and largest flux control-coefficients. We hypothesize that biochemical networks for cellular signaling have a different strategy for minimizing energy waste and being efficient than do biochemical networks for biosynthesis. We also discuss the intimate relationship between MCA and biochemical systems analysis (BSA).

  17. [Identification of hepatitis B virus YMDD point mutation using peptide nucleic acid clamping PCR].

    PubMed

    Zhang, Yingying; He, Haitang; Yang, Jie; Hou, Jinlin

    2013-06-01

    To establish a peptide nucleic acid clamping PCR assay for detecting hepatitis B virus (HBV) drug resistance mutation. RtM204I (ATT) mutant, rtM204V (GTG) mutant and rtM204 (ATG) wild-type plasmids mixed at different ratios were detected for mutations by PNA clamping PCR assay and direct sequencing, and the sensitivity and specificity of the two methods were compared. Serum samples from 85 patients with chronic HBV infection were detected for drug resistance using the two methods. The sensitivity of PNA-PCR assay was 0.001% in a 10(5)-fold excess of wild-type HBV DNA with a detection limit of 10(1) copies. The sensitivity of direct sequencing was 10% with a detection limit of 10(4) copies. Mutants were detected in 73 of the 85 serum samples (85.9%), including YIDD in 40 samples, YVDD in 23 samples, and YIDD+YVDD in 10 samples. The agreement of PNA-PCR assay with direct sequencing was only 40% (34/85, YIDD in 21 samples, YVDD in 11 samples, and YIDD+YVDD in 2 samples). Neither of the two methods yielded positive results for the negative control samples, suggesting their good specificity. PNA-PCR assay appears to be a more sensitive and rapid assay for detection of HBV genotypic resistance.

  18. Predictions for neutral K and B meson physics

    NASA Astrophysics Data System (ADS)

    Dimopoulos, Savas; Hall, Lawrence J.; Raby, Stuart

    1992-12-01

    Using supersymmetric grand unified theories, we have recently invented a framework which allows the prediction of three quark masses, two of the parameters of the Kobayashi-Maskawa matrix, and tanβ, the ratio of the two electroweak vacuum expectation values. These predictions are used to calculate ɛ and ɛ' in the kaon system, the mass mixing in the B0d and B0s systems, and the size of CP asymmetries in the decays of neutral B mesons to explicit final states of given CP.

  19. Saddle clamp assembly

    NASA Technical Reports Server (NTRS)

    Belrose, Charles R. (Inventor)

    1994-01-01

    A saddle clamp assembly is presented. The assembly is comprised of a hollow cylindrical body centered about a longitudinal axis and being diametrically split into semicircular top and bottom sections. Each section has a pair of connection flanges, at opposite ends, that project radially outward. A pair of bolts are retained on the top section flanges and are threadable into nuts retained on the bottom section flanges. A base member is anchored to a central underside portion of the bottom clamp body section and has a pair of connection tabs positioned beneath the bottom clamp body section connection flanges on opposite sides of the clamp axis. A pair of bolts are retained on the base member connection tabs and are threadable into a pair of nuts retainable on a support structure. The connection tab and connection flanges on each side of the clamp body are axially offset in a manner permitting downward installation/removable tool access to the lower bolts past the connection flanges. An elongated retention tether is used to connect the top clamp body section to the balance of the clamp assembly. This prevents loss of the top clamp body section when it is removed from the bottom clamp body section.

  20. Actions speak louder than words: Outsiders' perceptions of diversity mixed messages.

    PubMed

    Windscheid, Leon; Bowes-Sperry, Lynn; Kidder, Deborah L; Cheung, Ho Kwan; Morner, Michèle; Lievens, Filip

    2016-09-01

    To attract a gender diverse workforce, many employers use diversity statements to publicly signal that they value gender diversity. However, this often represents a misalignment between words and actions (i.e., a diversity mixed message) because most organizations are male dominated, especially in board positions. We conducted 3 studies to investigate the potentially indirect effect of such diversity mixed messages through perceived behavioral integrity on employer attractiveness. In Study 1, following a 2 × 2 design, participants (N = 225) were either shown a pro gender diversity statement or a neutral statement, in combination with a gender diverse board (4 men and 4 women) or a uniform all-male board (8 men). Participants' perceived behavioral integrity of the organization was assessed. In Study 2, participants (N = 251) either read positive or negative reviews of the organization's behavioral integrity. Employer attractiveness was then assessed. Study 3 (N = 427) investigated the impact of board gender composition on perceived behavioral integrity and employer attractiveness using a bootstrapping procedure. Both the causal-chain design of Study 1 and 2, as well as the significance test of the proposed indirect relationship in Study 3, revealed that a diversity mixed message negatively affected an organization's perceived behavioral integrity, and low behavioral integrity in turn negatively impacted employer attractiveness. In Study 3, there was also evidence for a tipping point (more than 1 woman on the board was needed) with regard to participants' perceptions of the organization's behavioral integrity. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  1. Evolutionary advantage via common action of recombination and neutrality

    NASA Astrophysics Data System (ADS)

    Saakian, David B.; Hu, Chin-Kun

    2013-11-01

    We investigate evolution models with recombination and neutrality. We consider the Crow-Kimura (parallel) mutation-selection model with the neutral fitness landscape, in which there is a central peak with high fitness A, and some of 1-point mutants have the same high fitness A, while the fitness of other sequences is 0. We find that the effect of recombination and neutrality depends on the concrete version of both neutrality and recombination. We consider three versions of neutrality: (a) all the nearest neighbor sequences of the peak sequence have the same high fitness A; (b) all the l-point mutations in a piece of genome of length l≥1 are neutral; (c) the neutral sequences are randomly distributed among the nearest neighbors of the peak sequences. We also consider three versions of recombination: (I) the simple horizontal gene transfer (HGT) of one nucleotide; (II) the exchange of a piece of genome of length l, HGT-l; (III) two-point crossover recombination (2CR). For the case of (a), the 2CR gives a rather strong contribution to the mean fitness, much stronger than that of HGT for a large genome length L. For the random distribution of neutral sequences there is a critical degree of neutrality νc, and for μ<μc and (μc-μ) is not large, the 2CR suppresses the mean fitness while HGT increases it; for ν much larger than νc, the 2CR and HGT-l increase the mean fitness larger than that of the HGT. We also consider the recombination in the case of smooth fitness landscapes. The recombination gives some advantage in the evolutionary dynamics, where recombination distinguishes clearly the mean-field-like evolutionary factors from the fluctuation-like ones. By contrast, mutations affect the mean-field-like and fluctuation-like factors similarly. Consequently, recombination can accelerate the non-mean-field (fluctuation) type dynamics without considerably affecting the mean-field-like factors.

  2. Search for heavy neutral lepton production in K+ decays

    NASA Astrophysics Data System (ADS)

    Cortina Gil, E.; Minucci, E.; Padolski, S.; Petrov, P.; Velghe, B.; Georgiev, G.; Kozhuharov, V.; Litov, L.; Numao, T.; Bryman, D.; Fu, J.; Husek, T.; Kampf, K.; Zamkovsky, M.; Aliberti, R.; Khoriauli, G.; Kunze, J.; Lomidze, D.; Marchevski, R.; Peruzzo, L.; Vormstein, M.; Wanke, R.; Dalpiaz, P.; Fiorini, M.; Gamberini, E.; Neri, I.; Norton, A.; Petrucci, F.; Wahl, H.; Cotta Ramusino, A.; Gianoli, A.; Iacopini, E.; Latino, G.; Lenti, M.; Bizzeti, A.; Bucci, F.; Volpe, R.; Antonelli, A.; Gonnella, F.; Lamanna, G.; Lanfranchi, G.; Mannocchi, G.; Martellotti, S.; Moulson, M.; Raggi, M.; Spadaro, T.; Ambrosino, F.; Capussela, T.; Corvino, M.; Di Filippo, D.; Massarotti, P.; Mirra, M.; Napolitano, M.; Saracino, G.; Anzivino, G.; Brizioli, F.; Imbergamo, E.; Lollini, R.; Santoni, C.; Barbanera, M.; Cenci, P.; Checcucci, B.; Duk, V.; Lubrano, P.; Lupi, M.; Pepe, M.; Piccini, M.; Costantini, F.; Di Lella, L.; Doble, N.; Giorgi, M.; Giudici, S.; Pedreschi, E.; Sozzi, M.; Cerri, C.; Fantechi, R.; Piandani, R.; Pinzino, J.; Pontisso, L.; Spinella, F.; Mannelli, I.; D'Agostini, G.; Biagioni, A.; Leonardi, E.; Lonardo, A.; Valente, P.; Vicini, P.; Ammendola, R.; Bonaiuto, V.; De Simone, N.; Federici, L.; Fucci, A.; Salamon, A.; Sargeni, F.; Arcidiacono, R.; Bloch-Devaux, B.; Boretto, M.; Iacobuzio, L.; Menichetti, E.; Migliore, E.; Soldi, D.; Biino, C.; Filippi, A.; Marchetto, F.; Engelfried, J.; Estrada-Tristan, N.; Bragadireanu, A. M.; Ghinescu, S. A.; Hutanu, O. E.; Enik, T.; Falaleev, V.; Kekelidze, V.; Korotkova, A.; Madigozhin, D.; Misheva, M.; Molokanova, N.; Movchan, S.; Polenkevich, I.; Potrebenikov, Yu.; Shkarovskiy, S.; Zinchenko, A.; Fedotov, S.; Gushchin, E.; Khotyantsev, A.; Kleimenova, A.; Kudenko, Y.; Kurochka, V.; Medvedeva, M.; Mefodev, A.; Shaikhiev, A.; Kholodenko, S.; Kurshetsov, V.; Obraztsov, V.; Ostankov, A.; Semenov, V.; Sugonyaev, V.; Yushchenko, O.; Bician, L.; Blazek, T.; Cerny, V.; Koval, M.; Kucerova, Z.; Ceccucci, A.; Danielsson, H.; Duval, F.; Döbrich, B.; Gatignon, L.; Guida, R.; Hahn, F.; Jenninger, B.; Laycock, P.; Lehmann Miotto, G.; Lichard, P.; Mapelli, A.; Noy, M.; Palladino, V.; Perrin-Terrin, M.; Ruggiero, G.; Ryjov, V.; Venditti, S.; Brunetti, M. B.; Fascianelli, V.; Goudzovski, E.; Lazzeroni, C.; Lurkin, N.; Newson, F.; Parkinson, C.; Romano, A.; Sergi, A.; Sturgess, A.; Swallow, J.; Heath, H.; Page, R.; Trilov, S.; Angelucci, B.; Britton, D.; Graham, C.; Protopopescu, D.; Dainton, J. B.; Fry, J. R.; Fulton, L.; Hutchcroft, D.; Massri, K.; Maurice, E.; Wrona, B.; Conovaloff, A.; Cooper, P.; Coward, D.; Rubin, P.; NA62 Collaboration

    2018-03-01

    A search for heavy neutral lepton production in K+ decays using a data sample collected with a minimum bias trigger by the NA62 experiment at CERN in 2015 is reported. Upper limits at the 10-7 to 10-6 level are established on the elements of the extended neutrino mixing matrix |Ue4|2 and |Uμ4|2 for heavy neutral lepton mass in the ranges 170-448 MeV/c2 and 250-373 MeV/c2, respectively. This improves on the previous limits from HNL production searches over the whole mass range considered for |Ue4|2, and above 300 MeV/c2 for |Uμ4|2.

  3. Electrical coupling of single cardiac rat myocytes to field-effect and bipolar transistors.

    PubMed

    Kind, Thomas; Issing, Matthias; Arnold, Rüdiger; Müller, Bernt

    2002-12-01

    A novel bipolar transistor for extracellular recording the electrical activity of biological cells is presented, and the electrical behavior compared with the field-effect transistor (FET). Electrical coupling is examined between single cells separated from the heart of adults rats (cardiac myocytes) and both types of transistors. To initiate a local extracellular voltage, the cells are periodically stimulated by a patch pipette in voltage clamp and current clamp mode. The local extracellular voltage is measured by the planar integrated electronic sensors: the bipolar and the FET. The small signal transistor currents correspond to the local extracellular voltage. The two types of sensor transistors used here were developed and manufactured in the laboratory of our institute. The manufacturing process and the interfaces between myocytes and transistors are described. The recordings are interpreted by way of simulation based on the point-contact model and the single cardiac myocyte model.

  4. 46 CFR 128.420 - Keel cooler installations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-metallic hose-clamps may be used at machinery connections if— (1) The clamps are of a corrosion-resistant material; (2) The clamps do not depend on spring tension for their holding power; and (3) Two of the clamps...

  5. High throughput ion-channel pharmacology: planar-array-based voltage clamp.

    PubMed

    Kiss, Laszlo; Bennett, Paul B; Uebele, Victor N; Koblan, Kenneth S; Kane, Stefanie A; Neagle, Brad; Schroeder, Kirk

    2003-02-01

    Technological advances often drive major breakthroughs in biology. Examples include PCR, automated DNA sequencing, confocal/single photon microscopy, AFM, and voltage/patch-clamp methods. The patch-clamp method, first described nearly 30 years ago, was a major technical achievement that permitted voltage-clamp analysis (membrane potential control) of ion channels in most cells and revealed a role for channels in unimagined areas. Because of the high information content, voltage clamp is the best way to study ion-channel function; however, throughput is too low for drug screening. Here we describe a novel breakthrough planar-array-based HT patch-clamp technology developed by Essen Instruments capable of voltage-clamping thousands of cells per day. This technology provides greater than two orders of magnitude increase in throughput compared with the traditional voltage-clamp techniques. We have applied this method to study the hERG K(+) channel and to determine the pharmacological profile of QT prolonging drugs.

  6. The photobase generator nifedipine as a novel matrix for the detection of polyphenols in matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Nguyen, Huu-Nghi; Tanaka, Mitsuru; Komabayashi, Genki; Matsui, Toshiro

    2016-10-01

    Matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is widely used for the detection and analysis of ionizable compounds. However, the method has less potential for the analysis of neutral compounds, such as polyphenols, owing to their lack of favorable proton-attachment or -removal groups. In this study, we reported for the first time that nifedipine (2,6-dimethyl-3,5-dicarbomethoxy-4-(2-nitrophenyl)-1,4-dihydropyridine), which is a strong photobase generator commonly used in polymerization, can abstract protons from neutral compounds in negative mode-MALDI experiments. When nifedipine (5 mg/ml) was used as a matrix reagent, the limit of detection (LOD) for epigallocatechin-3-O-gallate (EGCG) was determined to be 100 fmol/spot, which constitutes >50-fold improvement compared to the LOD obtained when trans-3-indoleacrylic acid, a matrix reagent previously reported for polyphenol detection, was used. Of the dihydropyridines investigated, only nifedipine facilitated the detection of EGCG, suggesting that the nitrosophenyl pyridine derivative of nifedipine formed by photoreduction under laser irradiation at 355 nm plays a crucial role in detecting polyphenols in negative mode. Reduced MS detection of 5-O-methylnaringenin indicated that nifedipine may preferably remove a proton from the 5-position OH group in the A ring of the flavonoid skeleton. The significant MS detection by nifedipine was extensively observed for polyphenols including flavones, flavonones, chalcones, stilbenoids and phenolic acids. In conclusion, nifedipine can act as a novel matrix for improving polyphenol detection by MALDI-MS in negative mode. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Investigation of indirect excitons in bulk 2H-MoS2 using transmission electron energy-loss spectroscopy

    NASA Astrophysics Data System (ADS)

    Habenicht, Carsten; Schuster, Roman; Knupfer, Martin; Büchner, Bernd

    2018-05-01

    We have investigated indirect excitons in bulk 2H-MoS2 using transmission electron energy-loss spectroscopy. The electron energy-loss spectra were measured for various momentum transfer values parallel to the and directions of the Brillouin zone. The results allowed the identification of the indirect excitons between the valence band K v and conduction band Λc points, the Γv and K c points as well as adjacent K v and points. The energy-momentum dispersions for the K v-Λc, Γv-K c and K v1- excitons along the line are presented. The former two transitions exhibit a quadratic dispersion which allowed calculating their effective exciton masses based on the effective mass approximation. The K v1- transition follows a more linear dispersion relationship.

  8. Indirect determination of the thermodynamic temperature of the copper point by a multi-fixed-point technique

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Florio, M.; Girard, F.

    2010-06-01

    An indirect determination of the thermodynamic temperature of the fixed point of copper was made at INRIM by measuring four cells with a Si-based and an InGaAs-based precision radiation thermometer carrying approximated thermodynamic scales realized up to the Ag point. An average value TCu = 1357.840 K was found with a standard uncertainty of 0.047 K. A consequent (T - T90)Cu value of 70 mK can be derived which is 18 mK higher than, but consistent with, the presently available (T - T90)Cu as elaborated by the CCT-WG4.

  9. A method of indirect registration of the coordinates of condylar points with a six-degree-of-freedom jaw tracker.

    PubMed

    Huang, B Y; Durrant, C J; Johnson, C W L; Murray, G M

    2002-06-30

    Previous studies have indicated that the location of a condylar point can significantly influence its trajectory. The aim of this investigation was to develop a method of registering the location of radiographically defined condylar points in the coordinate system of a six-degree-of-freedom jaw-tracking device and to determine the accuracy of this method by using a perspex model in one experiment and a dry skull in another. A direct measurement ('the gold standard') of condylar point coordinates in the coordinate system of JAWS3D was done using a three-dimensional (3D) digitizer (MicroScribe-3DX). The indirect measurement used a distributed fiducial marker as the interface between the coordinate system of MicroScribe-3DX (which was used to register the fiducial marker and the JAWS3D coordinate system) and the coordinate system of the CT scans (used to define condyle anatomy and the relation with the fiducial marker). The coordinates of condylar points could then be calculated in the coordinate system of JAWS3D. The results showed that the indirect method could register condylar point coordinates on either side to an accuracy of approximately 0.5 mm.

  10. When Belief Ascriptions Are about More than What Is on Someone Else's Mind

    ERIC Educational Resources Information Center

    Hansen, Mikkel B.; Petersen, Esben N.; Poulsen, Arne; Salès-Wuillemin, Edith

    2017-01-01

    The third-person belief ascription, "Marie believes that the contract is in the cabinet," may engender two interpretations: (1) It neutrally describes what is on Marie's mind and (2) it offers indirect evidence about reality, committing the speaker to the cabinet as the most likely location. The circumstances that lead to the evidential…

  11. Detachable clamps for minimal access surgery.

    PubMed

    Frank, T; Willetts, G J; Cuschieri, A

    1995-01-01

    A detachable clamp and applicator have been developed for use in minimal access surgical operations involving hollow visceral transection and anastomosis. The clamp has parallel jaws which ensure uniform distribution of the occlusive force. Following application on the bowel, the clamp is released from the applicator, thus freeing the access port. On completion of the anastomosis, the clamp is docked to the applicator, its jaws opened for release from the bowel and then closed prior to removal. The jaws of the clamp are kept closed by a pseudoelastic nickel-titanium (NiTi) alloy spring which imparts advantageous force characteristics when compared to stainless steel. The excellent holding and atraumatic characteristics of the detachable clamp have been confirmed by use in laparoscopic and thoracoscopic surgery on the gastrointestinal tract.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, John; Gilchrist, Phillip Charles

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solarmore » panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.« less

  13. A novel high performance ESD power clamp circuit with a small area

    NASA Astrophysics Data System (ADS)

    Zhaonian, Yang; Hongxia, Liu; Li, Li; Qingqing, Zhuo

    2012-09-01

    A MOSFET-based electrostatic discharge (ESD) power clamp circuit with only a 10 ns RC time constant for a 0.18-μm process is proposed. A diode-connected NMOSFET is used to maintain a long delay time and save area. The special structure overcomes other shortcomings in this clamp circuit. Under fast power-up events, the gate voltage of the clamp MOSFET does not rise as quickly as under ESD events, the special structure can keep the clamp MOSFET thoroughly off. Under a falsely triggered event, the special structure can turn off the clamp MOSFET in a short time. The clamp circuit can also reject the power supply noise effectively. Simulation results show that the clamp circuit avoids fast false triggering events such as a 30 ns/1.8 V power-up, maintains a 1.2 μs delay time and a 2.14 μs turn-off time, and reduces to about 70% of the RC time constant. It is believed that the proposed clamp circuit can be widely used in high-speed integrated circuits.

  14. Does indirect speech promote nondirective genetic counseling? Results of a sociolinguistic investigation.

    PubMed

    Benkendorf, J L; Prince, M B; Rose, M A; De Fina, A; Hamilton, H E

    2001-01-01

    To date, research examining adherence to genetic counseling principles has focused on specific counseling activities such as the giving or withholding of information and responding to client requests for advice. We audiotaped 43 prenatal genetic counseling sessions and used data-driven, qualitative, sociolinguistic methodologies to investigate how language choices facilitate or hinder the counseling process. Transcripts of each session were prepared for sociolinguistic analysis of the emergent discourse that included studying conversational style, speaker-listener symmetry, directness, and other interactional patterns. Analysis of our data demonstrates that: 1) indirect speech, marked by the use of hints, hedges, and other politeness strategies, facilitates rapport and mitigates the tension between a client-centered relationship and a counselor-driven agenda; 2) direct speech, or speaking literally, is an effective strategy for providing information and education; and 3) confusion exists between the use of indirect speech and the intent to provide nondirective counseling, especially when facilitating client decision-making. Indirect responses to client questions, such as those that include the phrases "some people" or "most people," helped to maintain counselor neutrality; however, this well-intended indirectness, used to preserve client autonomy, may have obstructed direct explorations of client needs. We argue that the genetic counseling process requires increased flexibility in the use of direct and indirect speech and provide new insights into how "talk" affects the work of genetic counselors.

  15. Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.

    PubMed

    Maeda, Takuma; Hattori, Kohshi; Sumiyoshi, Miho; Kanazawa, Hiroko; Ohnishi, Yoshihiko

    2018-06-01

    The fourth-generation FloTrac/Vigileo™ improved its algorithm to follow changes in systemic vascular resistance index (SVRI). This revision may improve the accuracy and trending ability of CI even in patients who undergo abdominal aortic aneurysm (AAA) surgery which cause drastic change of SVRI by aortic clamping. The purpose of this study is to elucidate the accuracy and trending ability of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery by comparing the FloTrac/Vigileo™-derived CI (CI FT ) with that measured by three-dimensional echocardiography (CI 3D ). Twenty-six patients undergoing elective AAA surgery were included in this study. CI FT and CI3 D were determined simultaneously in eight points including before and after aortic clamp. We used CI 3D as the reference method. In the Bland-Altman analysis, CI FT had a wide limit of agreement with CI 3D showing a percentage error of 46.7%. Subgroup analysis showed that the percentage error between CO 3D and CO FT was 56.3% in patients with cardiac index < 2.5 L/min/m 2 and 28.4% in patients with cardiac index ≥ 2.5 L/min/m 2 . SVRI was significantly higher in patients with cardiac index < 2.5 L/min/m 2 (1703 ± 330 vs. 2757 ± 798; p < 0.001). The tracking ability of fourth generation of FloTrac/Vigileo™ after aortic clamp was not clinically acceptable (26.9%). The degree of accuracy of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery was not acceptable. The tracking ability of the fourth-generation FloTrac/Vigileo™ after aortic clamp was below the acceptable limit.

  16. West Nile virus--neutralizing antibodies in humans in Greece.

    PubMed

    Papa, Anna; Perperidou, Parthena; Tzouli, Anisa; Castilletti, Concetta

    2010-10-01

    Serum samples collected during March-May 2007 from 392 residents of Imathia prefecture, Northern Greece, were tested by indirect immunofluorescence assay and enzyme-linked immunosorbent assay for IgG antibodies against West Nile virus (WNV). Microneutralization assay was applied in six positive samples. Four (4/392, 1.02%) were found positive for WNV-neutralizing antibodies. None of the positive individuals had a history of travel in endemic area or flavivirus vaccination, suggesting that WNV, or an antigenically related flavivirus, circulates in an endemic sylvatic cycle, at least locally, in rural areas in Greece. Human, animal, and vector surveillance systems have to be implemented to provide an early detection of WNV activity in Greece.

  17. Dipeptide-based Polyphosphazene and Polyester Blends for Bone Tissue Engineering

    PubMed Central

    Deng, Meng; Nair, Lakshmi S.; Nukavarapu, Syam P.; Jiang, Tao; Kanner, William A.; Li, Xudong; Kumbar, Sangamesh G.; Weikel, Arlin L.; Krogman, Nicholas R.; Allcock, Harry R.; Laurencin, Cato T.

    2010-01-01

    Polyphosphazene-polyester blends are attractive materials for bone tissue engineering applications due to their controllable degradation pattern with non-toxic and neutral pH degradation products. In our ongoing quest for an ideal completely miscible polyphosphazene-polyester blend system, we report synthesis and characterization of a mixed-substituent biodegradable polyphosphazene poly[(glycine ethyl glycinato)1(phenyl phenoxy)1phosphazene] (PNGEG/PhPh) and its blends with a polyester. Two dipeptide-based blends namely 25:75 (Matrix1) and 50:50 (Matrix2) were produced at two different weight ratios of PNGEG/PhPh to poly(lactic acid-glycolic acid) (PLAGA). Blend miscibility was confirmed by differential scanning calorimetry, Fourier transform infrared spectroscopy, and scanning electron microscopy. Both blends resulted in higher tensile modulus and strength than the polyester. The blends showed a degradation rate in the order of Matrix2 < Matrix1 < PLAGA in phosphate buffered saline at 37°C over 12 weeks. Significantly higher pH values of degradation media were observed for blends compared to PLAGA confirming the neutralization of PLAGA acidic degradation by polyphosphazene hydrolysis products. The blend components PLAGA and polyphosphazene exhibited a similar degradation pattern as characterized by the molecular weight loss. Furthermore, blends demonstrated significantly higher osteoblast growth rates compared to PLAGA while maintaining osteoblast phenotype over a 21-day culture. Both blends demonstrated improved biocompatibility in a rat subcutaneous implantation model compared to PLAGA over 12 weeks. PMID:20334909

  18. Performance of hybrid nano-micro reinforced mg metal matrix composites brake calliper: simulation approach

    NASA Astrophysics Data System (ADS)

    Fatchurrohman, N.; Chia, S. T.

    2017-10-01

    Most commercial vehicles use brake calliper made of grey cast iron (GCI) which possesses heavy weight. This contributes to the total weight of the vehicle which can lead to higher fuel consumption. Another major problem is GCI calliper tends to deflect during clamping action, known as “bending of bridge”. This will result in extended pedal travel. Magnesium metal matrix composites (Mg-MMC) has a potential application in the automotive industry since it having a lower density, higher strength and very good modulus of elasticity as compared to GCI. This paper proposed initial development of hybrid Mg-MMC brake calliper. This was achieved by analyzing the performance of hybrid nano-micro reinforced Mg-MMC and comparing with the conventional GCI brake calliper. It was performed using simulation in ANSYS, a finite element analysis (FEA) software. The results show that hybrid Mg-MMC has better performance in terms of reduction the weight of the brake calliper, reduction in total deformation/deflection and better ability to withstand equivalent elastic strain.

  19. Theoretical Infrared Spectra for Polycyclic Aromatic Hydrocarbon Neutrals, Cations and Anions

    NASA Technical Reports Server (NTRS)

    Langhoff, Stephen R.

    1995-01-01

    Calculations are carried out using density functional theory (DFT) to determine the harmonic frequencies and intensities of the neutrals and cations of thirteen polycyclic aromatic hydrocarbons (PAHs) up to the size of ovalene. Calculations are also carried out for a few PAH anions. The DFT harmonic frequencies, when uniformly scaled by the factor of 0.958 to account primarily for anharmonicity, agree with the matrix isolation fundamentals to within an average error of about 10 per centimeter. Electron correlation is found to significantly reduce the intensities of many of the cation harmonics, bringing them into much better agreement with the available experimental data. While the theoretical infrared spectra agree well with the experimental data for the neutral systems and for many of the cations, there are notable discrepancies with the experimental matrix isolation data for some PAH cations that are difficult to explain in terms of limitations in the calculations. In agreement with previous theoretical work, the present calculations show that the relative intensities for the astronomical unidentified infrared (UIR) bands agree reasonably well with those for a distribution of polycyclic aromatic hydrocarbon (PAH) cations, but not with a distribution of PAH neutrals. We also observe that the infrared spectra of highly symmetrical cations such as coronene agree much better with astronomical observations than do those of, for example, the polyacenes such as tetracene and pentacene. The total integrated intensities for the neutral species are found to increase linearly with size, while the total integrated intensities are much larger for the cations and scale more nearly quadratically with size. We conclude that emission from moderate-sized highly symmetric PAH cations such as coronene and larger could account for the UIR bands.

  20. Aesthetic guidelines for second-generation indirect inlay and onlay composite restorations.

    PubMed

    Miara, P

    1998-05-01

    Recent innovations in indirect composite technology and adhesive bonding procedures have resulted in the development of advanced materials particularly suited for inlay and onlay restorations. Microhybrid composite resins are characterized by a filler/matrix ratio that is significantly greater than that of earlier materials. This article reviews the physical properties and clinical application of these "second-generation" composite resins, with emphasis on a system that utilizes a heat-curing process in conjunction with nitrogen pressure to fabricate a material with improved mechanical and aesthetic properties.

  1. Photoionization of the valence shells of the neutral tungsten atom

    NASA Astrophysics Data System (ADS)

    Ballance, C. P.; McLaughlin, B. M.

    2015-04-01

    Results from large-scale theoretical cross section calculations for the total photoionization (PI) of the 4f, 5s, 5p and 6s orbitals of the neutral tungsten atom using the Dirac Coulomb R-matrix approximation (DARC: Dirac-atomic R-matrix codes) are presented. Comparisons are made with previous theoretical methods and prior experimental measurements. In previous experiments a time-resolved dual laser approach was employed for the photo-absorption of metal vapours and photo-absorption measurements on tungsten in a solid, using synchrotron radiation. The lowest ground state level of neutral tungsten is 5{{p}6}5{{d}4}6{{s}2}{{ }5}{{D}J}, with J = 0, and requires only a single dipole matrix for PI. To make a meaningful comparison with existing experimental measurements, we statistically average the large-scale theoretical PI cross sections from the levels associated with the ground state 5{{p}6}5{{d}4}6{{s}2}{{ }5}{{D}J} (J = 0, 1, 2, 3, 4) levels and the 5{{d}5}6{{s} 7}{{S}3} excited metastable level. As the experiments have a self-evident metastable component in their ground state measurement, averaging over the initial levels allows for a more consistent and realistic comparison to be made. In the wider context, the absence of many detailed electron-impact excitation (EIE) experiments for tungsten and its multi-charged ion stages allows current PI measurements and theory to provide a road-map for future EIE, ionization and di-electronic cross section calculations by identifying the dominant resonance structure and features across an energy range of hundreds of eV.

  2. A three dimensional point cloud registration method based on rotation matrix eigenvalue

    NASA Astrophysics Data System (ADS)

    Wang, Chao; Zhou, Xiang; Fei, Zixuan; Gao, Xiaofei; Jin, Rui

    2017-09-01

    We usually need to measure an object at multiple angles in the traditional optical three-dimensional measurement method, due to the reasons for the block, and then use point cloud registration methods to obtain a complete threedimensional shape of the object. The point cloud registration based on a turntable is essential to calculate the coordinate transformation matrix between the camera coordinate system and the turntable coordinate system. We usually calculate the transformation matrix by fitting the rotation center and the rotation axis normal of the turntable in the traditional method, which is limited by measuring the field of view. The range of exact feature points used for fitting the rotation center and the rotation axis normal is approximately distributed within an arc less than 120 degrees, resulting in a low fit accuracy. In this paper, we proposes a better method, based on the invariant eigenvalue principle of rotation matrix in the turntable coordinate system and the coordinate transformation matrix of the corresponding coordinate points. First of all, we control the rotation angle of the calibration plate with the turntable to calibrate the coordinate transformation matrix of the corresponding coordinate points by using the least squares method. And then we use the feature decomposition to calculate the coordinate transformation matrix of the camera coordinate system and the turntable coordinate system. Compared with the traditional previous method, it has a higher accuracy, better robustness and it is not affected by the camera field of view. In this method, the coincidence error of the corresponding points on the calibration plate after registration is less than 0.1mm.

  3. Drum ring removal/installation tool

    DOEpatents

    Andrade, William Andrew [Livermore, CA

    2006-11-14

    A handheld tool, or a pair of such tools, such as for use in removing/installing a bolt-type clamping ring on a container barrel/drum, where the clamping ring has a pair of clamping ends each with a throughbore. Each tool has an elongated handle and an elongated lever arm transversely connected to one end of the handle. The lever arm is capable of being inserted into the throughbore of a selected clamping end and leveraged with the handle to exert a first moment on the selected clamping end. Each tool also has a second lever arm, such as a socket with an open-ended slot, which is suspended alongside the first lever arm. The second lever arm is capable of engaging the selected clamping end and being leveraged with the handle to exert a second moment which is orthogonal to the first moment. In this manner, the first and second moments operate to hold the selected clamping end fixed relative to the tool so that the selected clamping end may be controlled with the handle. The pair of clamping ends may also be simultaneously and independently controlled with the use of two handles/tools so as to contort the geometry of the drum clamping ring and enable its removal/installation.

  4. An isolated Hda-clamp complex is functional in the regulatory inactivation of DnaA and DNA replication.

    PubMed

    Kawakami, Hironori; Su'etsugu, Masayuki; Katayama, Tsutomu

    2006-10-01

    In Escherichia coli, a complex consisting of Hda and the DNA-loaded clamp-subunit of the DNA polymerase III holoenzyme promotes hydrolysis of DnaA-ATP. The resultant ADP-DnaA is inactive for initiation of chromosomal DNA replication, thereby repressing excessive initiations. As the cellular content of the clamp is 10-100 times higher than that of Hda, most Hda molecules might be complexed with the clamp in vivo. Although Hda predominantly forms irregular aggregates when overexpressed, in the present study we found that co-overexpression of the clamp with Hda enhances Hda solubility dramatically and we efficiently isolated the Hda-clamp complex. A single molecule of the complex appears to consist of two Hda molecules and a single clamp. The complex is competent in DnaA-ATP hydrolysis and DNA replication in the presence of DNA and the clamp deficient subassembly of the DNA polymerase III holoenzyme (pol III*). These findings indicate that the clamp contained in the complex is loaded onto DNA through an interaction with the pol III* and that the Hda activity is preserved in these processes. The complex consisting of Hda and the DNA-unloaded clamp may play a specific role in a process proceeding to the DnaA-ATP hydrolysis in vivo.

  5. Simulating Matrix Crack and Delamination Interaction in a Clamped Tapered Beam

    NASA Technical Reports Server (NTRS)

    De Carvalho, N. V.; Seshadri, B. R.; Ratcliffe, J. G.; Mabson, G. E.; Deobald, L. R.

    2017-01-01

    Blind predictions were conducted to validate a discrete crack methodology based on the Floating Node Method to simulate matrix-crack/delamination interaction. The main novel aspects of the approach are: (1) the implementation of the floating node method via an 'extended interface element' to represent delaminations, matrix-cracks and their interaction, (2) application of directional cohesive elements to infer overall delamination direction, and (3) use of delamination direction and stress state at the delamination front to determine migration onset. Overall, good agreement was obtained between simulations and experiments. However, the validation exercise revealed the strong dependence of the simulation of matrix-crack/delamination interaction on the strength data (in this case transverse interlaminar strength, YT) used within the cohesive zone approach applied in this work. This strength value, YT, is itself dependent on the test geometry from which the strength measurement is taken. Thus, choosing an appropriate strength value becomes an ad-hoc step. As a consequence, further work is needed to adequately characterize and assess the accuracy and adequacy of cohesive zone approaches to model small crack growth and crack onset. Additionally, often when simulating damage progression with cohesive zone elements, the strength is lowered while keeping the fracture toughness constant to enable the use of coarser meshes. Results from the present study suggest that this approach is not recommended for any problem involving crack initiation, small crack growth or multiple crack interaction.

  6. Global asymptotic stability to a generalized Cohen-Grossberg BAM neural networks of neutral type delays.

    PubMed

    Zhang, Zhengqiu; Liu, Wenbin; Zhou, Dongming

    2012-01-01

    In this paper, we first discuss the existence of a unique equilibrium point of a generalized Cohen-Grossberg BAM neural networks of neutral type delays by means of the Homeomorphism theory and inequality technique. Then, by applying the existence result of an equilibrium point and constructing a Lyapunov functional, we study the global asymptotic stability of the equilibrium solution to the above Cohen-Grossberg BAM neural networks of neutral type. In our results, the hypothesis for boundedness in the existing paper, which discussed Cohen-Grossberg neural networks of neutral type on the activation functions, are removed. Finally, we give an example to demonstrate the validity of our global asymptotic stability result for the above neural networks. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Radiation in the earth's atmosphere: its radiance, polarization, and ellipticity.

    PubMed

    Hitzfelder, S J; Plass, G N; Kattawar, G W

    1976-10-01

    The complete radiation field including polarization is calculated by the matrix operator method for a model of the real atmosphere. The radiance, direction and amount of polarization, and ellipticity are obtained at the top and bottom of the atmosphere for three values of the surface albedo (0, 0.15, 0.90) and five solar zenith angles. Scattering and absorption by molecules (including ozone) and by aerosols are taken into account together with the variation of the number density of these substances with height. All results are calculated for both a normal aerosol number and a distribution that is one-third of the normal amount at all heights. The calculated values show general qualitative agreement with the available experimental measurements. The position of the neutral points of the polarization in the principal plane is a sensitive indicator of the characteristics of the aerosol particles in the atmosphere, since it depends on the sign and value of the single scattered polarization for scattering angles around 20 degrees and 160 degrees for transmitted and reflected photons, respectively. This, in turn, depends on the index of refraction and size distribution of the aerosols. The neutral point position does not depend appreciably on the surface albedo and, over a considerable range, depends little on the solar zenith angle. The value of the maximum polarization in the principal plane depends on the aerosol amount, surface albedo, and solar zenith angle. It could be used to measure the aerosol amount. The details of the ellipticity curves are similar to those for scattering from pure aerosol layers and, thus, are little modified by the Rayleigh scattering. Aerosols could be identified by their characteristic ellipticity curves.

  8. Photochemical Reactions of Particulate Organic Matter: Deciphering the Role of Direct and Indirect Processes

    NASA Astrophysics Data System (ADS)

    Carrasquillo, A. J.; Gelfond, C. E.; Kocar, B. D.

    2016-12-01

    Photochemical reactions of natural organic matter (NOM) represent potentially important pathways for biologically recalcitrant material to be chemically altered in aquatic systems. Irradiation can alter the physical state of organic matter by facilitating the cycling between the particulate (POM) and dissolved (DOM) pools, however, a molecular level understanding of this chemically dynamic system is currently lacking. Photochemical reactions of a target molecule proceed by the direct absorption of a photon, or through reaction with a second photolytically generated species (i.e. the hydroxyl radical, singlet oxygen, excited triplet state NOM, hydrogen peroxide, etc.). Here, we isolate the major direct and indirect photochemical reactions of a lignocellulose-rich POM material (Phragmites australis) to determine their relative importance in changing the the chemical structure of the parent POM, and in the production of DOM. We measured POM molecular structure using a combination of NMR and FTIR for bulk analyses and scanning transmission x-ray microscopy (STXM) for spatially resolved chemistry, while the chemical composition of photo-produced DOM was measured using ultra-high resolution mass spectrometry. Results are discussed in the context of the differences in chemical composition of both NOM pools resulting from the isolated photochemical pathways. All treatments result in an increase in DOM with reaction time, indicating that the larger POM matrix is likely fragmenting into smaller more soluble species. Spectroscopic measurements, on the other hand, point to functionalization reactions which increase the abundance of alcohol, acid, and carbonyl moieties in both carbon pools. This unique dataset provides new insight into how photochemical reactions alter the chemical composition of NOM while highlighting the relative importance of indirect pathways.

  9. A preconcentration method for indirect determination of acrylamide from chips, crackers and cereal-based baby foods using flame atomic absorption spectrometry.

    PubMed

    Altunay, Nail; Gürkan, Ramazan; Orhan, Ulaş

    2016-12-01

    Acrylamide is a toxic species for human health, and is a Maillard reaction product which forms spontaneously in heat treatment process of foods. Therefore, a simple, fast and cost-effective method was developed for the indirect determination of acrylamide in processed foods particularly consumed by children. The method is based on ion-pairing of acrylamide with fluorescein (F 2- ) in presence of Ni(II) ions at pH 9.0, and then extraction of the formed ternary complex into micellar phase of poly(ethyleneglycol-mono-p-nonylphenylether) (PONPE 7.5) before analysis by flame atomic absorption spectrometry (FAAS). The ultrasonic-assisted cloud point extraction (UA-CPE) has been used for the preconcentration of acrylamide in the samples prior to its FAAS detection. The matrix matched calibration curve is linear in range of 0.3-150µgkg -1 under optimal reagent conditions (1.75mL of 0.1molL -1 ammonia buffer at pH 9.0, 2.2mgL -1 Ni(II), 4.0×10 -4 molL -1 F 2- , 0.4% (w/v) NH 4 Cl and 0.7% (v/v) PONPE 7.5) with sensitivity enhancement of 160-fold. The proposed method has been validated by assessment of the following parameters; the limits of detection (LOD) and quantification (LOQ) (0.08µgkg -1 and 0.28µgkg -1 , respectively) with a relative standard deviation (RSD%) lower than 6.3%, and extractive recovery higher than 95% for acrylamide spiked at levels of 5 and 25µgkg -1 . The method was successfully applied to the indirect determination of acrylamide in the processed foods and two CRMs with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Comprehension and utilisation of pointing gestures and gazing in dog-human communication in relatively complex situations.

    PubMed

    Lakatos, Gabriella; Gácsi, Márta; Topál, József; Miklósi, Adám

    2012-03-01

    The aim of the present investigation was to study the visual communication between humans and dogs in relatively complex situations. In the present research, we have modelled more lifelike situations in contrast to previous studies which often relied on using only two potential hiding locations and direct association between the communicative signal and the signalled object. In Study 1, we have provided the dogs with four potential hiding locations, two on each side of the experimenter to see whether dogs are able to choose the correct location based on the pointing gesture. In Study 2, dogs had to rely on a sequence of pointing gestures displayed by two different experimenters. We have investigated whether dogs are able to recognise an 'indirect signal', that is, a pointing toward a pointer. In Study 3, we have examined whether dogs can understand indirect information about a hidden object and direct the owner to the particular location. Study 1 has revealed that dogs are unlikely to rely on extrapolating precise linear vectors along the pointing arm when relying on human pointing gestures. Instead, they rely on a simple rule of following the side of the human gesturing. If there were more targets on the same side of the human, they showed a preference for the targets closer to the human. Study 2 has shown that dogs are able to rely on indirect pointing gestures but the individual performances suggest that this skill may be restricted to a certain level of complexity. In Study 3, we have found that dogs are able to localise the hidden object by utilising indirect human signals, and they are able to convey this information to their owner.

  11. Electrostatic Interactions at the Dimer Interface Stabilize the E. coli β Sliding Clamp.

    PubMed

    Purohit, Anirban; England, Jennifer K; Douma, Lauren G; Tondnevis, Farzaneh; Bloom, Linda B; Levitus, Marcia

    2017-08-22

    Sliding clamps are ring-shaped oligomeric proteins that encircle DNA and associate with DNA polymerases for processive DNA replication. The dimeric Escherichia coli β-clamp is closed in solution but must adopt an open conformation to be assembled onto DNA by a clamp loader. To determine what factors contribute to the stability of the dimer interfaces in the closed conformation and how clamp dynamics contribute to formation of the open conformation, we identified conditions that destabilized the dimer and measured the effects of these conditions on clamp dynamics. We characterized the role of electrostatic interactions in stabilizing the β-clamp interface. Increasing salt concentration results in decreased dimer stability and faster subunit dissociation kinetics. The equilibrium dissociation constant of the dimeric clamp varies with salt concentration as predicted by simple charge-screening models, indicating that charged amino acids contribute to the remarkable stability of the interface at physiological salt concentrations. Mutation of a charged residue at the interface (Arg-103) weakens the interface significantly, whereas effects are negligible when a hydrophilic (Ser-109) or a hydrophobic (Ile-305) amino acid is mutated instead. It has been suggested that clamp opening by the clamp loader takes advantage of spontaneous opening-closing fluctuations at the clamp's interface, but our time-resolved fluorescence and fluorescence correlation experiments rule out conformational fluctuations that lead to a significant fraction of open states. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  12. An alternative derivation of the stationary distribution of the multivariate neutral Wright-Fisher model for low mutation rates with a view to mutation rate estimation from site frequency data.

    PubMed

    Schrempf, Dominik; Hobolth, Asger

    2017-04-01

    Recently, Burden and Tang (2016) provided an analytical expression for the stationary distribution of the multivariate neutral Wright-Fisher model with low mutation rates. In this paper we present a simple, alternative derivation that illustrates the approximation. Our proof is based on the discrete multivariate boundary mutation model which has three key ingredients. First, the decoupled Moran model is used to describe genetic drift. Second, low mutation rates are assumed by limiting mutations to monomorphic states. Third, the mutation rate matrix is separated into a time-reversible part and a flux part, as suggested by Burden and Tang (2016). An application of our result to data from several great apes reveals that the assumption of stationarity may be inadequate or that other evolutionary forces like selection or biased gene conversion are acting. Furthermore we find that the model with a reversible mutation rate matrix provides a reasonably good fit to the data compared to the one with a non-reversible mutation rate matrix. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  13. Longitudinal Analysis of Early HIV-1-Specific Neutralizing Activity in an Elite Neutralizer and in Five Patients Who Developed Cross-Reactive Neutralizing Activity

    PubMed Central

    Euler, Zelda; van den Kerkhof, Tom L. G. M.; van Gils, Marit J.; Burger, Judith A.; Edo-Matas, Diana; Phung, Pham; Wrin, Terri

    2012-01-01

    We previously established that at 3 years postseroconversion, ∼30% of HIV-infected individuals have cross-reactive neutralizing activity (CrNA) in their sera. Here we studied the kinetics with which CrNA develops and how these relate to the development of autologous neutralizing activity as well as viral escape and diversification. For this purpose, sera from five individuals with CrNA and one elite neutralizer that were obtained at three monthly intervals in the first year after seroconversion and at multiple intervals over the disease course were tested for neutralizing activity against an established multiclade panel of six viruses. The same serum samples, as well as sera from three individuals who lacked CrNA, were tested for their neutralizing activities against autologous clonal HIV-1 variants from multiple time points covering the disease course from seroconversion onward. The elite neutralizer already had CrNA at 9.8 months postseroconversion, in contrast with the findings for the other five patients, in whom CrNA was first detected at 20 to 35 months postseroconversion and peaked around 35 months postseroconversion. In all patients, CrNA coincided with neutralizing activity against autologous viruses that were isolated <12 months postseroconversion, while viruses from later time points had already escaped autologous neutralizing activity. Also, the peak in gp160 sequence diversity coincided with the peak of CrNA titers. Individuals who lacked CrNA had lower peak autologous neutralizing titers, viral escape, and sequence diversity than individuals with CrNA. A better understanding of the underlying factors that determine the presence of CrNA or even an elite neutralizer phenotype may aid in the design of an HIV-1 vaccine. PMID:22156522

  14. Evaluation of endothelin-1 and MMPs-2, -9, -14 in cerebrospinal fluid as indirect indicators of blood-brain barrier dysfunction in chronic canine hypothyroidism.

    PubMed

    Pancotto, Theresa E; Rossmeisl, John H; Huckle, William R; Inzana, Karen D; Zimmerman, Kurt L

    2016-04-01

    Chronic canine hypothyroidism is associated with blood-brain barrier (BBB) disruption. We hypothesized that this change is mediated by endothelin-1(ET-1) and matrix metalloproteinases (MMP) -2, -9, and -14, as evidenced by increased concentrations of these proteins in cerebrospinal fluid (CSF) compared to controls. CSF from 18 dogs, 9 controls and 9 with experimentally induced hypothyroidism was collected before and 6, 12, and 18 months after induction of hypothyroidism. Concentrations of ET-1 using an ELISA kit, and for MMP-2, -9, and -14 using gelatinase zymography were measured in CSF. ET-1 was undetectable in CSF of control and hypothyroid dogs at all time-points. Constitutively expressed MMP-2 was detectable in CSF samples in all dogs at all time-points. No other MMPs were detectable in CSF. No differences in CSF concentrations of ET-1 and MMP-2, 9, and 14 were found between hypothyroid and euthyroid dogs. Therefore, ET-1 and MMP-2, 9, and 14 are unlikely to be primary mediators of BBB damage in chronically hypothyroid dogs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Welding fixture for joining bar-wound stator conductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Souza, Urban J.; Rhoads, Frederick W.; Hanson, Justin

    A fixture assembly for welding a plurality of stator wire end pairs may include an anvil, a movable clamp configured to translate between an unclamped state and a clamped state, a first grounding electrode, and a second grounding electrode. The movable clamp may be configured to urge the plurality of stator wire ends against the anvil when in the clamped state. The moveable clamp includes a separator feature that generally extends toward the anvil. Each of the first grounding electrode and second grounding electrodes may be configured to translate between a clamped state and an unclamped state. When in themore » clamped state, each of the first and second grounding electrodes is configured to urge a pair of the plurality of stator wire end pairs against the separator feature.« less

  16. A comparison between the minimal model and the glucose clamp in the assessment of insulin sensitivity across the spectrum of glucose tolerance. Insulin Resistance Atherosclerosis Study.

    PubMed

    Saad, M F; Anderson, R L; Laws, A; Watanabe, R M; Kades, W W; Chen, Y D; Sands, R E; Pei, D; Savage, P J; Bergman, R N

    1994-09-01

    An insulin-modified frequently sampled intravenous glucose tolerance test (FSIGTT) with minimal model analysis was compared with the glucose clamp in 11 subjects with normal glucose tolerance (NGT), 20 with impaired glucose tolerance (IGT), and 24 with non-insulin-dependent diabetes mellitus (NIDDM). The insulin sensitivity index (SI) was calculated from FSIGTT using 22- and 12-sample protocols (SI(22) and SI(12), respectively). Insulin sensitivity from the clamp was expressed as SI(clamp) and SIP(clamp). Minimal model parameters were similar when calculated with SI(22) and SI(12). SI could not be distinguished from 0 in approximately 50% of diabetic patients with either protocol. SI(22) correlated significantly with SI(clamp) in the whole group (r = 0.62), and in the NGT (r = 0.53), IGT (r = 0.48), and NIDDM (r = 0.41) groups (P < 0.05 for each). SI(12) correlated significantly with SI(clamp) in the whole group (r = 0.55, P < 0.001) and in the NGT (r = 0.53, P = 0.046) and IGT (r = 0.58, P = 0.008) but not NIDDM (r = 0.30, P = 0.085) groups. When SI(22), SI(clamp), and SIP(clamp) were expressed in the same units, SI(22) was 66 +/- 5% (mean +/- SE) and 50 +/- 8% lower than SI(clamp) and SIP(clamp), respectively. Thus, minimal model analysis of the insulin-modified FSIGTT provides estimates of insulin sensitivity that correlate significantly with those from the glucose clamp. The correlation was weaker, however, in NIDDM. The insulin-modified FSIGTT can be used as a simple test for assessment of insulin sensitivity in population studies involving nondiabetic subjects. Additional studies are needed before using this test routinely in patients with NIDDM.

  17. Arterial waves in humans during peripheral vascular surgery.

    PubMed

    Khir, A W; Henein, M Y; Koh, T; Das, S K; Parker, K H; Gibson, D G

    2001-12-01

    The purpose of this study was to investigate the effect of aortic clamping on arterial waves during peripheral vascular surgery. We measured pressure and velocity simultaneously in the ascending aorta, in ten patients (70+/-5 years) with aortic-iliac disease intra-operatively. Pressure was measured using a catheter tip manometer, and velocity was measured using Doppler ultrasound. Data were collected before aortic clamping, during aortic clamping and after unclamping. Hydraulic work in the aortic root was calculated from the measured data, the reflected waves were determined by wave-intensity analysis and wave speed was determined by the PU-loop (pressure-velocity-loop) method; a new technique based on the 'water-hammer' equation. The wave speed is approx. 32% (P<0.05) higher during clamping than before clamping. Although the peak intensity of the reflected wave does not alter with clamping, it arrives 30 ms (P<0.05) earlier and its duration is 25% (P<0.05) longer than before clamping. During clamping, left ventricule (LV) hydraulic systolic work and the energy carried by the reflected wave increased by 27% (P<0.05) and 20% (P<0.05) respectively, compared with before clamping. The higher wave speed during clamping explains the earlier arrival of the reflected waves suggesting an increase in the afterload, since the LV has to overcome earlier reflected compression waves. The longer duration of the reflected wave during clamping is associated with an increase in the total energy carried by the wave, which causes an increase in hydraulic work. Increased hydraulic work during clamping may increase LV oxygen consumption, provoke myocardial ischaemia and hence contribute to the intra-operative impairment of LV function known in patients with peripheral vascular disease.

  18. In situ analysis of plant tissue underivatized carbohydrates and on-probe enzymatic degraded starch by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry by using carbon nanotubes as matrix.

    PubMed

    Gholipour, Yousef; Nonami, Hiroshi; Erra-Balsells, Rosa

    2008-12-15

    Underivatized carbohydrates of tulip bulb and leaf tissues were characterized in situ by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) by using carbon nanotubes (CNTs) as matrix. Two sample preparation methods--(i) depositing CNTs on the fresh tissue slices placed on the probe and (ii) locating semitransparent tissues on a dried layer of CNTs on the probe--were examined. Furthermore, practicability of in situ starch analysis by MALDI-TOF MS was examined by detection of glucose originated from on-probe amyloglucosidase-catalyzed degradation of starch on the tissue surface. Besides, CNTs could efficiently desorb/ionize natural mono-, di-, and oligosaccharides extracted from tulip bulb tissues as well as glucose resulting from starch enzymatic degradation in vitro. These results were compared with those obtained by in situ MALDI-TOF MS analysis of similar tissues. Positive ion mode showed superior signal reproducibility. CNTs deposited under semitransparent tissue could also desorb/ionize neutral carbohydrates, leading to nearly complete elimination of matrix cluster signals but with an increase in tissue-originated signals. Furthermore, several experiments were carried out to compare the efficiency of 2,5-dihydroxybenzoic acid, nor-harmane, alpha-cyano-4-hydroxycinnamic acid, and CNTs as matrices for MALDI of neutral carbohydrates from the intact plant tissue surface and for enzymatic tissue starch degradation; these results are discussed in brief. Among matrices studied, the lowest laser power was needed to acquire carbohydrate signals with high signal-to-noise ratio and resolution when CNTs were used.

  19. Low dose prednisolone and insulin sensitivity differentially affect arterial stiffness and endothelial function: An open interventional and cross-sectional study.

    PubMed

    Petersons, Carolyn J; Mangelsdorf, Brenda L; Poljak, Anne; Smith, Malcolm D; Greenfield, Jerry R; Thompson, Campbell H; Burt, Morton G

    2017-03-01

    Glucocorticoids could impair vascular function directly, or indirectly by reducing insulin sensitivity. The aim of this study was to determine the direct and indirect effects of acute and chronic low dose prednisolone on arterial stiffness and endothelial function. Twelve subjects with inflammatory arthritis, who had not taken oral glucocorticoids for ≥6 months, and 12 subjects with inflammatory arthritis, taking chronic (>6 months) low dose (6.3 ± 2.2 mg/day) prednisolone, were studied. Patients not on glucocorticoids underwent measurement of arterial stiffness (pulse wave velocity (PWV)) and endothelial function (reactive hyperaemia index (RHI)) before and after 7-10 days of prednisolone (6 mg/day), to assess the acute effects of prednisolone. Baseline data from patients not on glucocorticoids were compared with patients on long-term prednisolone to assess the chronic effects of prednisolone. Hepatic insulin sensitivity was estimated from percentage suppression of endogenous glucose production and peripheral insulin sensitivity as glucose infusion rate (M/I) during a hyperinsulinaemic-euglycaemic clamp. There were no significant changes in PWV with acute (9.2 ± 0.8 vs. 8.9 ± 0.8 m/sec, p = 0.33) or chronic (8.9 ± 0.8 vs. 9.0 ± 0.7 m/sec, p = 0.69) prednisolone. In multiple regression analysis, PWV was negatively associated with M/I during hyperinsulinemic-euglycemic clamp (p = 0.02), but not with suppression of endogenous glucose production (p = 0.15) or glucocorticoid use (p = 0.70). Chronic (2.4 ± 0.2 vs. 1.9 ± 0.1, p = 0.02), but not acute (1.8 ± 0.2 vs. 1.9 ± 0.1, p = 0.24), prednisolone resulted in a higher RHI. Arterial stiffness is not affected by low dose prednisolone per se, but is negatively associated with peripheral insulin sensitivity. Patients with rheumatoid arthritis taking long-term prednisolone had better endothelial function. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. MAGP1, the extracellular matrix, and metabolism

    PubMed Central

    Craft, Clarissa S

    2014-01-01

    Adipose tissue and the extracellular matrix were once considered passive players in regulating physiological processes. Now, both entities are acknowledged for their capacity to engage signal transduction pathways, and for their involvement in maintaining normal tissue homeostasis. We recently published a series of studies that identified a novel mechanism whereby an extracellular matrix molecule, MAGP1 (microfibril associated glycoprotein 1), can regulate energy metabolism in adipose tissue. MAGP1 is a component of extracellular microfibrils and plays a supportive role in maintaining thermoregulation by indirectly regulating expression of the thermogenic uncoupling proteins (UCPs). The focus of this commentary is to draw attention to the role of the extracellular matrix in regulating the bioavailability of signaling molecules, like transforming growth factor β (TGFβ), and exemplify that a better understanding of the extracellular matrix's biological properties could unveil a new source of therapeutic targets for metabolic diseases. PMID:26167404

  1. MAGP1, the extracellular matrix, and metabolism.

    PubMed

    Craft, Clarissa S

    2015-01-01

    Adipose tissue and the extracellular matrix were once considered passive players in regulating physiological processes. Now, both entities are acknowledged for their capacity to engage signal transduction pathways, and for their involvement in maintaining normal tissue homeostasis. We recently published a series of studies that identified a novel mechanism whereby an extracellular matrix molecule, MAGP1 (microfibril associated glycoprotein 1), can regulate energy metabolism in adipose tissue. MAGP1 is a component of extracellular microfibrils and plays a supportive role in maintaining thermoregulation by indirectly regulating expression of the thermogenic uncoupling proteins (UCPs). The focus of this commentary is to draw attention to the role of the extracellular matrix in regulating the bioavailability of signaling molecules, like transforming growth factor β (TGFβ), and exemplify that a better understanding of the extracellular matrix's biological properties could unveil a new source of therapeutic targets for metabolic diseases.

  2. Stochastic determination of matrix determinants

    NASA Astrophysics Data System (ADS)

    Dorn, Sebastian; Enßlin, Torsten A.

    2015-07-01

    Matrix determinants play an important role in data analysis, in particular when Gaussian processes are involved. Due to currently exploding data volumes, linear operations—matrices—acting on the data are often not accessible directly but are only represented indirectly in form of a computer routine. Such a routine implements the transformation a data vector undergoes under matrix multiplication. While efficient probing routines to estimate a matrix's diagonal or trace, based solely on such computationally affordable matrix-vector multiplications, are well known and frequently used in signal inference, there is no stochastic estimate for its determinant. We introduce a probing method for the logarithm of a determinant of a linear operator. Our method rests upon a reformulation of the log-determinant by an integral representation and the transformation of the involved terms into stochastic expressions. This stochastic determinant determination enables large-size applications in Bayesian inference, in particular evidence calculations, model comparison, and posterior determination.

  3. Stochastic determination of matrix determinants.

    PubMed

    Dorn, Sebastian; Ensslin, Torsten A

    2015-07-01

    Matrix determinants play an important role in data analysis, in particular when Gaussian processes are involved. Due to currently exploding data volumes, linear operations-matrices-acting on the data are often not accessible directly but are only represented indirectly in form of a computer routine. Such a routine implements the transformation a data vector undergoes under matrix multiplication. While efficient probing routines to estimate a matrix's diagonal or trace, based solely on such computationally affordable matrix-vector multiplications, are well known and frequently used in signal inference, there is no stochastic estimate for its determinant. We introduce a probing method for the logarithm of a determinant of a linear operator. Our method rests upon a reformulation of the log-determinant by an integral representation and the transformation of the involved terms into stochastic expressions. This stochastic determinant determination enables large-size applications in Bayesian inference, in particular evidence calculations, model comparison, and posterior determination.

  4. Clamp-mount device

    NASA Technical Reports Server (NTRS)

    Clark, K. H. (Inventor)

    1983-01-01

    A clamp-mount device is disclosed for mounting equipment to an associated I-beam and the like structural member of the type having oppositely extending flanges wherein the device comprises a base and a pair of oppositely facing clamping members carried diagonally on the base clamping flanges therebetween and having flange receiving openings facing one another. Lock means are carried diagonally by the base opposite the clamping members locking the flanges in the clamping members. A resilient hub is carried centrally of the base engaging and biasing a back side of the flanges maintaining tightly clamped and facilitating use on vertical as well as horizontal members. The base turns about the hub to receive the flanges within the clamping members. Equipment may be secured to the base by any suitable means such as bolts in openings. Slidable gate latches secure the hinged locks in an upright locking position. The resilient hub includes a recess opening formed in the base and a rubber-like pad carried in this opening being depressably and rotatably carried therein.

  5. The RNA polymerase clamp interconverts dynamically among three states and is stabilized in a partly closed state by ppGpp.

    PubMed

    Duchi, Diego; Mazumder, Abhishek; Malinen, Anssi M; Ebright, Richard H; Kapanidis, Achillefs N

    2018-06-06

    RNA polymerase (RNAP) contains a mobile structural module, the 'clamp,' that forms one wall of the RNAP active-center cleft and that has been linked to crucial aspects of the transcription cycle, including promoter melting, transcription elongation complex stability, transcription pausing, and transcription termination. Using single-molecule FRET on surface-immobilized RNAP molecules, we show that the clamp in RNAP holoenzyme populates three distinct conformational states and interconvert between these states on the 0.1-1 s time-scale. Similar studies confirm that the RNAP clamp is closed in open complex (RPO) and in initial transcribing complexes (RPITC), including paused initial transcribing complexes, and show that, in these complexes, the clamp does not exhibit dynamic behaviour. We also show that, the stringent-response alarmone ppGpp, which reprograms transcription during amino acid starvation stress, selectively stabilizes the partly-closed-clamp state and prevents clamp opening; these results raise the possibility that ppGpp controls promoter opening by modulating clamp dynamics.

  6. Structural analysis of a eukaryotic sliding DNA clamp-clamp loadercomplex.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, Gregory D.; O'Donnell, Mike; Kuriyan, John

    2006-06-17

    Sliding clamps are ring-shaped proteins that encircle DNA and confer high processivity on DNA polymerases. Here we report the crystal structure of the five-protein clamp loader complex (replication factor-C, RFC) of the yeast Saccharomyces cerevisiae, bound to the sliding clamp (proliferating cell nuclear antigen, PCNA). Tight interfacial coordination of the ATP analogue ATP-?-S by RFC results in a spiral arrangement of the ATPase domains of the clamp loader above the PCNA ring. Placement of a model for primed DNA within the central hole of PCNA reveals a striking correspondence between the RFC spiral and the grooves of the DNA doublemore » helix. This model, in which the clamp loader complex locks onto primed DNA in a screw-cap-like arrangement, provides a simple explanation for the process by which the engagement of primer-template junctions by the RFC:PCNA complex results in ATP hydrolysis and release of the sliding clamp on DNA.« less

  7. Evaluation of Introduction of a Delayed Cord Clamping Protocol for Premature Neonates in a High-Volume Maternity Center.

    PubMed

    Liu, Lilly Y; Feinglass, Joe M; Khan, Janine Y; Gerber, Susan E; Grobman, William A; Yee, Lynn M

    2017-05-01

    To evaluate adherence to a delayed cord clamping protocol for preterm births in the first 2 years after its introduction, perform a quality improvement assessment, and determine neonatal outcomes associated with protocol implementation and adherence. This is a retrospective cohort study of women delivering singleton neonates at 23-32 weeks of gestation in the 2 years before (preprotocol) and 2 years after (postprotocol) introduction of a 30-second delayed cord clamping protocol at a large-volume academic center. This policy was communicated to obstetric and pediatric health care providers and nurses and reinforced with intermittent educational reviews. Barriers to receiving delayed cord clamping were assessed using χ tests and multivariable logistic regression. Neonatal outcomes then were compared between all neonates in the preprotocol period and all neonates in the postprotocol period and between all neonates in the preprotocol period and neonates receiving delayed cord clamping in the postprotocol period using multivariable linear and logistic regression analyses. Of the 427 eligible neonates, 187 were born postprotocol. Of these, 53.5% (n=100) neonates received delayed cord clamping according to the protocol. The rate of delayed cord clamping preprotocol was 0%. Protocol uptake and frequency of delayed cord clamping increased over the 2 years after its introduction. In the postprotocol period, cesarean delivery was the only factor independently associated with failing to receive delayed cord clamping (adjusted odds ratio [OR] 0.49, 95% confidence interval [CI] 0.25-0.96). In comparison with the preprotocol period, those who received delayed cord clamping in the postprotocol period had significantly higher birth hematocrit (β=2.46, P=.007) and fewer blood transfusions in the first week of life (adjusted OR 0.49, 95% CI 0.25-0.96). After introduction of an institutional delayed cord clamping protocol followed by continued health care provider education and quality feedback, the frequency of delayed cord clamping progressively increased. Compared with historical controls, performing delayed cord clamping in eligible preterm neonates was associated with improved neonatal hematologic indices, demonstrating the effectiveness of delayed cord clamping in a large-volume maternity unit.

  8. a Global Registration Algorithm of the Single-Closed Ring Multi-Stations Point Cloud

    NASA Astrophysics Data System (ADS)

    Yang, R.; Pan, L.; Xiang, Z.; Zeng, H.

    2018-04-01

    Aimed at the global registration problem of the single-closed ring multi-stations point cloud, a formula in order to calculate the error of rotation matrix was constructed according to the definition of error. The global registration algorithm of multi-station point cloud was derived to minimize the error of rotation matrix. And fast-computing formulas of transformation matrix with whose implementation steps and simulation experiment scheme was given. Compared three different processing schemes of multi-station point cloud, the experimental results showed that the effectiveness of the new global registration method was verified, and it could effectively complete the global registration of point cloud.

  9. Investigation of indirect excitons in bulk 2H-MoS2 using transmission electron energy-loss spectroscopy.

    PubMed

    Habenicht, Carsten; Schuster, Roman; Knupfer, Martin; Büchner, Bernd

    2018-05-23

    We have investigated indirect excitons in bulk 2H-MoS 2 using transmission electron energy-loss spectroscopy. The electron energy-loss spectra were measured for various momentum transfer values parallel to the [Formula: see text] and [Formula: see text] directions of the Brillouin zone. The results allowed the identification of the indirect excitons between the valence band K v and conduction band Λ c points, the Γ v and K c points as well as adjacent K v and [Formula: see text] points. The energy-momentum dispersions for the K v -Λ c , Γ v -K c and K v1 -[Formula: see text] excitons along the [Formula: see text] line are presented. The former two transitions exhibit a quadratic dispersion which allowed calculating their effective exciton masses based on the effective mass approximation. The K v1 -[Formula: see text] transition follows a more linear dispersion relationship.

  10. A clamped rectangular plate containing a crack

    NASA Technical Reports Server (NTRS)

    Tang, R.; Erdogan, F.

    1985-01-01

    The general problem of a rectangular plate clamped along two parallel sides and containing a crack parallel to the clamps is considered. The problem is formulated in terms of a system of singular integral equations and the asymptotic behavior of the stress state near the corners is investigated. Numerical examples are considered for a clamped plate without a crack and with a centrally located crack, and the stress intensity factors and the stresses along the clamps are calculated.

  11. Force-Measuring Clamp

    NASA Technical Reports Server (NTRS)

    Nunnelee, Mark (Inventor)

    2004-01-01

    A precision clamp that accurately measures force over a wide range of conditions is described. Using a full bridge or other strain gage configuration. the elastic deformation of the clamp is measured or detected by the strain gages. Thc strain gages transmit a signal that corresponds to the degree of stress upon the clamp. Thc strain gage signal is converted to a numeric display. Calibration is achieved by ero and span potentiometers which enable accurate measurements by the force-measuring clamp.

  12. Striatal Direct and Indirect Pathway Output Structures are Differentially Altered in Mouse Models of Huntington's Disease.

    PubMed

    Barry, Joshua; Akopian, Garnik; Cepeda, Carlos; Levine, Michael S

    2018-04-24

    The present study examined synaptic communication between direct and indirect output pathway striatal medium-sized spiny neurons (MSNs) and their target structures, the substantia nigra pars reticulata (SNr) and the external globus pallidus (GPe) in two mouse models of Huntington's disease (HD). Cre-recombination, optogenetics, and whole-cell patch clamp recordings were used to determine alterations in intrinsic and synaptic properties of SNr and GPe neurons from both male and female symptomatic R6/2 (>60 days) and pre- (2 months) or symptomatic (10-12 months) YAC128 mice. Cell membrane capacitance was decreased whereas input resistance was increased in SNr neurons from R6/2, but not YAC128 mice. The amplitude of GABAergic responses evoked by optogenetic stimulation of direct pathway terminals was reduced in SNr neurons of symptomatic mice of both models. A decrease in spontaneous GABA synaptic activity, in particular large-amplitude events, in SNr neurons also was observed. Passive membrane properties of GPe neurons were not different between R6/2 or YAC128 mice and their control littermates. Similarly, the amplitude of GABA responses evoked by activation of indirect pathway MSN terminals and the frequency of spontaneous GABA synaptic activity were similar in HD and control animals. In contrast, the decay time of the evoked GABA response was significantly longer in cells from HD mice. Interestingly, activation of indirect pathway MSNs within the striatum evoked larger-amplitude responses in direct pathway MSNs. Together, these results demonstrate differential alterations in responses evoked by direct and indirect pathway terminals in SNr and GPe leading to striatal output imbalance and motor dysfunction. SIGNIFICANCE STATEMENT Previous work on Huntington's disease (HD) focused on striatal medium-sized spiny neurons (MSNs) almost exclusively. Little is known about the effects that alterations in the striatum have on output structures of the direct and indirect pathways, the substantia nigra pars reticulata (SNr) and the external segment of the globus pallidus (GPe), respectively. We combined electrophysiological and optogenetic methods to examine responses evoked by selective activation of terminals of direct and indirect pathway MSNs in SNr and GPe neurons in two mouse models of HD. We show a differential disruption of synaptic communication between the direct and indirect output pathways of the striatum with their target regions leading to an imbalance of striatal output, which will contribute to motor dysfunction. Copyright © 2018 the authors.

  13. Improved H mode with flat central q profile on EAST

    NASA Astrophysics Data System (ADS)

    Liu, Haiqing; Yang, Yao; Gao, Xiang; Zeng, Long; Qian, Jinping; Gong, Xianzu; Wan, Baonian; Ding, Weixing; Brower, David Lyn; EAST Team

    2017-10-01

    High betaN ( 1.8) plasma with good confinement (H98y2 1.1) on EAST tokamak has been reported recently. These ELMy H-mode plasmas with Bt = 1.6T, Ip = 400 kA and q95 4.5 were heated by lower hybrid wave and neutral beam injection. The internal transport barrier (ITB) and edge transport barrier (ETB) are both observed with m/n =1/1 fishbone, which were identified to clamp central q at values close to unity. Implying an improved H-mode with flat central q profile and absence of sawteeth, like other devices. Accurate q profile, key profile for developing scenarios aim at high performance H mode, were derived by Polarimeter-interferometer (POINT) measurement as constraint. Base on the optimized current profile, better confinement (H98y2 1.4) with an electron ITB was obtained also with flat central q profile and absence of sawteeth at high betaP ( 2) regime with Bt = 2.5T, Ip = 400 kA. Both high betaN regime and high betaP regime H mode, are characterized by a stationary flat central q profile q0 >=1, but typically close to 1, absence of sawteeth, H98(y,2) >1 and simultaneously, with ITB. This work is supported by the National Magnetic Confinement Fusion Program of China with Contract No. 2014GB106002 and partly supported by the US D.O.E. contract DESC0010469.

  14. Delayed clamping of the umbilical cord after delivery and implications for public cord blood banking.

    PubMed

    Allan, David S; Scrivens, Nicholas; Lawless, Tiffany; Mostert, Karen; Oppenheimer, Lawrence; Walker, Mark; Petraszko, Tanya; Elmoazzen, Heidi

    2016-03-01

    Public banking of umbilical cord blood units (CBUs) containing higher numbers of cells ensures timely engraftment after transplantation for increasing numbers of patients. Delayed clamping of the umbilical cord after birth may benefit some infants by preventing iron deficiency. Implications of delayed cord clamping for public cord blood banking remains unclear. CBUs collected by Canadian Blood Services at one collection site between November 1, 2014, and March 17, 2015, were analyzed. The delay in cord clamping after birth was timed and classified as "no delay," 20 to 60 seconds, more than 60 seconds, or more than 120 seconds. Of 367 collections, 100 reported no delay in clamping while clamping was delayed by 20 to 60 seconds (n = 69), more than 60 seconds (n = 98), or more than 120 seconds (n = 100) in the remaining cases. The mean volume and total nucleated cells (TNCs) in units with no delay in clamping were significantly greater than mean volumes for all categories of delayed clamping (Tukey's test, p < 0.05 for each comparison). The proportion of units with more than 1.5 × 10(9) TNCs was significantly reduced when clamping was delayed (p = 5.5 × 10(-8) ). The difference was most marked for cords that were clamped more than 120 seconds after delivery (6.2% compared with 39%). Delayed cord clamping greatly diminishes the volume and TNC count of units collected for a public cord blood bank. Creating an inventory of CBUs with high TNC content may take more time than expected. © 2015 AABB.

  15. Characterization of the proteins comprising the integral matrix of Strongylocentrotus purpuratus embryonic spicules

    NASA Technical Reports Server (NTRS)

    Killian, C. E.; Wilt, F. H.

    1996-01-01

    In the present study, we enumerate and characterize the proteins that comprise the integral spicule matrix of the Strongylocentrotus purpuratus embryo. Two-dimensional gel electrophoresis of [35S]methionine radiolabeled spicule matrix proteins reveals that there are 12 strongly radiolabeled spicule matrix proteins and approximately three dozen less strongly radiolabeled spicule matrix proteins. The majority of the proteins have acidic isoelectric points; however, there are several spicule matrix proteins that have more alkaline isoelectric points. Western blotting analysis indicates that SM50 is the spicule matrix protein with the most alkaline isoelectric point. In addition, two distinct SM30 proteins are identified in embryonic spicules, and they have apparent molecular masses of approximately 43 and 46 kDa. Comparisons between embryonic spicule matrix proteins and adult spine integral matrix proteins suggest that the embryonic 43-kDa SM30 protein is an embryonic isoform of SM30. An adult 49-kDa spine matrix protein is also identified as a possible adult isoform of SM30. Analysis of the SM30 amino acid sequences indicates that a portion of SM30 proteins is very similar to the carbohydrate recognition domain of C-type lectin proteins.

  16. 30 CFR 75.605 - Clamping of trailing cables to equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Clamping of trailing cables to equipment. 75... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.605 Clamping of trailing cables to equipment. [Statutory Provisions] Trailing cables shall be clamped to...

  17. Linear analysis near a steady-state of biochemical networks: Control analysis, correlation metrics and circuit theory

    PubMed Central

    Heuett, William J; Beard, Daniel A; Qian, Hong

    2008-01-01

    Background Several approaches, including metabolic control analysis (MCA), flux balance analysis (FBA), correlation metric construction (CMC), and biochemical circuit theory (BCT), have been developed for the quantitative analysis of complex biochemical networks. Here, we present a comprehensive theory of linear analysis for nonequilibrium steady-state (NESS) biochemical reaction networks that unites these disparate approaches in a common mathematical framework and thermodynamic basis. Results In this theory a number of relationships between key matrices are introduced: the matrix A obtained in the standard, linear-dynamic-stability analysis of the steady-state can be decomposed as A = SRT where R and S are directly related to the elasticity-coefficient matrix for the fluxes and chemical potentials in MCA, respectively; the control-coefficients for the fluxes and chemical potentials can be written in terms of RTBS and STBS respectively where matrix B is the inverse of A; the matrix S is precisely the stoichiometric matrix in FBA; and the matrix eAt plays a central role in CMC. Conclusion One key finding that emerges from this analysis is that the well-known summation theorems in MCA take different forms depending on whether metabolic steady-state is maintained by flux injection or concentration clamping. We demonstrate that if rate-limiting steps exist in a biochemical pathway, they are the steps with smallest biochemical conductances and largest flux control-coefficients. We hypothesize that biochemical networks for cellular signaling have a different strategy for minimizing energy waste and being efficient than do biochemical networks for biosynthesis. We also discuss the intimate relationship between MCA and biochemical systems analysis (BSA). PMID:18482450

  18. Ready to Use Tissue Construct for Military Bone & Cartilage Trauma

    DTIC Science & Technology

    2014-10-01

    during nail introduction and reaming. In the present study, we examined the load - bearing capacity and optimal internal fixation of a bone/poly-ε...segmental defect, (a) axial loading via ball bearing , (b) torsional loading via square clamp allowing axial displacement, (c) three-point bending of tibia...knee joints by simulating loads seen during ambulation and knee range of motion. Our central hypothesis is that an anatomically and

  19. Mechanical support of a ceramic gas turbine vane ring

    DOEpatents

    Shi, Jun; Green, Kevin E.; Mosher, Daniel A.; Holowczak, John E.; Reinhardt, Gregory E.

    2010-07-27

    An assembly for mounting a ceramic turbine vane ring onto a turbine support casing comprises a first metal clamping ring and a second metal clamping ring. The first metal clamping ring is configured to engage with a first side of a tab member of the ceramic turbine vane ring. The second metal clamping ring is configured to engage with a second side of the tab member such that the tab member is disposed between the first and second metal clamping rings.

  20. Active energy recovery clamping circuit to improve the performance of power converters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitaker, Bret; Barkley, Adam

    2017-05-09

    A regenerative clamping circuit for a power converter using clamping diodes to transfer charge to a clamping capacitor and a regenerative converter to transfer charge out of the clamping capacitor back to the power supply input connection. The regenerative converter uses a switch connected to the midpoint of a series connected inductor and capacitor. The ends of the inductor and capacitor series are connected across the terminals of the power supply to be in parallel with the power supply.

  1. The neutral current sheet and its radiation pairs of side sources in coronal mass ejections

    NASA Astrophysics Data System (ADS)

    Ji, Shu-Chen

    Using the data observed with the soft X-ray telescope, hard X-ray telescope aboard on Yohkoh and the Nobeyama Radioheliograph on 1998 April 23, a comprehensive study on soft X-ray coronal mass ejection (SXRCME) and radio Type IV burst is carried out and some significant results are obtained as follows: A magnetic capacity belt (MCB) between two magnetic dipole sources (MDSs) was found and there were only a few activitation sources (ASs). During the MCB changed into a magnetic energy belt (MEB) by the ASs, activating energy and shining material both concentrated to the neutral current sheet (NCS) in the course of its formation. When two MDSs were put through by the MEB, the NCS formed and the SXRCME occurred. The matter ejected not only from the NCS, but also from the whole MEB. The expanding loop of the SXRCME had two foot points, both were just two MDSs. The head of the expanding loop always tended to the foot point of the weak source, because it was equilibrium point of magnetic pressures coming from two foot points. For this reason, its locus was neutral line. From this, the neutral line can also determine the position of NCS. Finally, the radiation pairs of side sources of NCS on the MEB are found.

  2. Application of the matrix exponential kernel

    NASA Technical Reports Server (NTRS)

    Rohach, A. F.

    1972-01-01

    A point matrix kernel for radiation transport, developed by the transmission matrix method, has been used to develop buildup factors and energy spectra through slab layers of different materials for a point isotropic source. Combinations of lead-water slabs were chosen for examples because of the extreme differences in shielding properties of these two materials.

  3. Removal of β-lactam antibiotics from pharmaceutical wastewaters using photo-Fenton process at near-neutral pH.

    PubMed

    Giraldo-Aguirre, Ana L; Serna-Galvis, Efraím A; Erazo-Erazo, Edgar D; Silva-Agredo, Javier; Giraldo-Ospina, Héctor; Flórez-Acosta, Oscar A; Torres-Palma, Ricardo A

    2017-02-03

    In this work, the photo-Fenton process at near-neutral pH was applied for the removal of the β-lactam antibiotic oxacillin (OXA) in water using artificial and sunlight. Initially, the main variables of the process (Fe(II), H 2 O 2 , and light power) were optimized by a statistical factorial design (2 3 with center points). The experimental design indicated that 90 μmol L -1 of Fe(II), 10 mmol L -1 of H 2 O 2 , and 30 W of power light were the favorable conditions for degradation of OXA at 203 μmol L -1 . In the photo-Fenton system, the H 2 O 2 alone, UV-light/H 2 O 2 , and Fe(II)/H 2 O 2 subsystems presented a significant participation on antibiotic removal. Moreover, based on the primary organic transformation products, a mechanism of OXA degradation was proposed. Under the favorable operational conditions, both the pollutant and the antimicrobial activity were eliminated after 50 min of process application. Although at 480 min of treatment, only 5% of mineralization was achieved, the level of biodegradability of the solutions increased from 0.08 to 0.98. Interestingly, the presence of pharmaceutical additives (glucose, isopropanol, and oxalic acid) had a moderate interference on the efficiency of the pollutant removal. Additionally, the treatment at pilot scale of the β-lactam antibiotic in a pharmaceutical complex matrix using solar radiation allowed the complete removal of the pollutant and its associated antimicrobial activity in a very short time period (5 min). These results evidenced the applicability of the photo-Fenton process to treat wastewaters from pharmaceutical industry loaded with β-lactam antibiotics at near neutral pH values efficiently.

  4. Using Experiential Methods To Teach about Measurement Validity.

    ERIC Educational Resources Information Center

    Alderfer, Clayton P.

    2003-01-01

    Indirectly, instructor behavior provided two models for using a multitrait-multimethod matrix. Students who formulated their own concept, created empirical indicators, and assessed convergent and discriminant validity had better results than those who, influenced by classroom authority dynamics, followed a poorly formulated concept with a…

  5. Application of the R-matrix method to photoionization of molecules.

    PubMed

    Tashiro, Motomichi

    2010-04-07

    The R-matrix method has been used for theoretical calculation of electron collision with atoms and molecules for long years. The method was also formulated to treat photoionization process, however, its application has been mostly limited to photoionization of atoms. In this work, we implement the R-matrix method to treat molecular photoionization problem based on the UK R-matrix codes. This method can be used for diatomic as well as polyatomic molecules, with multiconfigurational description for electronic states of both target neutral molecule and product molecular ion. Test calculations were performed for valence electron photoionization of nitrogen (N(2)) as well as nitric oxide (NO) molecules. Calculated photoionization cross sections and asymmetry parameters agree reasonably well with the available experimental results, suggesting usefulness of the method for molecular photoionization.

  6. Analysis of nonderivatized steroids by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using C70 fullerene as matrix.

    PubMed

    Montsko, Gergely; Vaczy, Alexandra; Maasz, Gabor; Mernyak, Erzsebet; Frank, Eva; Bay, Csaba; Kadar, Zalan; Ohmacht, Robert; Wolfling, Janos; Mark, Laszlo

    2009-10-01

    Neutral steroid hormones are currently analyzed by gas or liquid chromatography/mass spectrometry based methods. Most of the steroid compounds, however, lack volatility and do not contain polar groups, which results in inadequate chromatographic behavior and low ionization efficiency. Derivatization of the steroids to form more volatile, thermostable, and charged products solves this difficulty, but the derivatization of compounds with unknown chemical moieties is not an easy task. In this study, a rapid, high-throughput, sensitive matrix-assisted laser desorption/ionization time-of-flight mass spectrometry method is described using C(70) fullerene as a matrix compound. The application of the method is demonstrated for five general sex steroids and for synthetic steroid compounds in both negative and positive ionization modes.

  7. Isolation of a matrix that binds medial Golgi enzymes

    PubMed Central

    1994-01-01

    Rat liver Golgi stacks were extracted with Triton X-100 at neutral pH. After centrifugation the low speed pellet contained two medial-Golgi enzymes, N-acetylglucosaminyltransferase I and mannosidase II, but no enzymes or markers from other parts of the Golgi apparatus. Both were present in the same structures which appeared, by electron microscopy, to be small remnants of cisternal membranes. The enzymes could be removed by treatment with low salt, leaving behind a salt pellet, which we term the matrix. Removal of salt caused specific re-binding of both enzymes to the matrix, with an apparent dissociation constant of 3 nM for mannosidase II. Re-binding was abolished by pretreatment of intact Golgi stacks with proteinase K, suggesting that the matrix was present between the cisternae. PMID:8106542

  8. Implementing Patch Clamp and Live Fluorescence Microscopy to Monitor Functional Properties of Freshly Isolated PKD Epithelium

    PubMed Central

    Pavlov, Tengis S.; Ilatovskaya, Daria V.; Palygin, Oleg; Levchenko, Vladislav; Pochynyuk, Oleh; Staruschenko, Alexander

    2015-01-01

    Cyst initiation and expansion during polycystic kidney disease is a complex process characterized by abnormalities in tubular cell proliferation, luminal fluid accumulation and extracellular matrix formation. Activity of ion channels and intracellular calcium signaling are key physiologic parameters which determine functions of tubular epithelium. We developed a method suitable for real-time observation of ion channels activity with patch-clamp technique and registration of intracellular Ca2+ level in epithelial monolayers freshly isolated from renal cysts. PCK rats, a genetic model of autosomal recessive polycystic kidney disease (ARPKD), were used here for ex vivo analysis of ion channels and calcium flux. Described here is a detailed step-by-step procedure designed to isolate cystic monolayers and non-dilated tubules from PCK or normal Sprague Dawley (SD) rats, and monitor single channel activity and intracellular Ca2+ dynamics. This method does not require enzymatic processing and allows analysis in a native setting of freshly isolated epithelial monolayer. Moreover, this technique is very sensitive to intracellular calcium changes and generates high resolution images for precise measurements. Finally, isolated cystic epithelium can be further used for staining with antibodies or dyes, preparation of primary cultures and purification for various biochemical assays. PMID:26381526

  9. Payload Launch Lock Mechanism

    NASA Technical Reports Server (NTRS)

    Young, Ken (Inventor); Hindle, Timothy (Inventor)

    2014-01-01

    A payload launch lock mechanism includes a base, a preload clamp, a fastener, and a shape memory alloy (SMA) actuator. The preload clamp is configured to releasibly restrain a payload. The fastener extends, along an axis, through the preload clamp and into the base, and supplies a force to the preload clamp sufficient to restrain the payload. The SMA actuator is disposed between the base and the clamp. The SMA actuator is adapted to receive electrical current and is configured, upon receipt of the electrical current, to supply a force that causes the fastener to elongate without fracturing. The preload clamp, in response to the fastener elongation, either rotates or pivots to thereby release the payload.

  10. Renoprotective effects of combined endothelin-converting enzyme/neutral endopeptidase inhibitor SLV338 in acute and chronic experimental renal damage.

    PubMed

    Sharkovska, Yuliya; Kalk, Philipp; von Websky, Karoline; Relle, Katharina; Pfab, Thiemo; Alter, Markus; Fischer, Yvan; Hocher, Berthold

    2011-01-01

    Acute kidney injury (AKI) as well as chronic renal failure are associated with a huge mortality/morbidity. However, so far no drugs have been approved for the treatment of acute kidney failure and only a few for the treatment of chronic kidney disease (CKD). We analysed the effect of SLV338, a neutral endopeptidase (NEP)/endothelin converting enzyme (ECE)-inhibitor in animal models of acute kidney failure as well as chronic renal failure. Acute renal failure was induced in male Wistar rats by uninephrectomy and clamping of the remaining kidney for 55 minutes. SLV338 (total dose: 4.9 mg/kg) or vehicle was continuously infused for 2 hours (starting 20 minutes prior to clamping). Sham operated animals served as controls. Plasma creatinine was measured at baseline and day 2 and 8 after renal ischemia-reperfusion. Hypertensive renal damage was induced in male Sprague Dawley rats by nitric oxide deficiency using L-NAME (50 mg/kg per day, added to drinking water for 4 weeks). One group was treated over the same time period with SLV338 (30 mg/kg per day, mixed with food). Systolic blood pressure was monitored weekly. At study end, urine and blood samples were collected and kidneys were harvested. Acute renal ischemia-reperfusion caused a 5-fold plasma creatinine elevation (day 2), which was significantly attenuated by more than 50% in animals treated with SLV338 (p < 0.05). Renal failure was accompanied by a 67% mortality in vehicle-treated rats, but only 20% after SLV338 treatment (p = 0.03 compared to sham controls). Chronic L-NAME administration caused hypertension, urinary albumin excretion, glomerulosclerosis, renal arterial remodelling, and renal interstitial fibrosis. Treatment with SLV338 did not significantly affect blood pressure, but abolished renal tissue damage (interstitial fibrosis, glomerulosclerosis, renal arterial remodelling (p < 0.05 versus L-NAME group in each case). The dual ECE/NEP inhibitor SLV338 preserves kidney function and reduces mortality in severe acute ischemic renal failure. Moreover, combined ECE/NEP inhibition prevents hypertensive renal tissue damage in a blood pressure independent manner in L-NAME-treated rats.

  11. Interactions of GRF(1-29)NH2 with plasma proteins and their effects on the release of the peptide from a PLAGA matrix.

    PubMed

    Mariette, B; Coudane, J; Vert, M

    2005-09-02

    The administration of the GRF(1-29)NH2 Growth Hormone Releasing Hormone analog is known as relevant of the concept of drug delivery system using a bioresorbable matrix. However, the release of this peptide from poly(dl-lactic acid-co-glycolic acid) matrices is affected by its insolubility at neutral in salted media and in plasma as well. In order to investigate the origin and the nature of the insolubility in these media in more details, the precipitates collected when the peptide was set in contact with saline, isotonic pH=7.4 phosphate buffer and plasma were analyzed by various techniques, namely weighting, gel chromatography, 1D- and 2D-immunoelectrophoresis, and dialysis to discern the soluble from the insoluble or aggregated fractions. It is shown that precipitation in protein-free salted media is due to a salting out phenomenon complemented by the neutralization of the solubilizing electrostatic charges in the isotonic buffer. In contrast, the precipitation in plasma is due to inter polyelectrolyte-type complexation that involved polyanionic proteins having a rather low isoelectric point like albumin, transferin, haptoglobulin and IgG immunoglobulins. When a rather large quantity of GRF(1-29)NH2 was entrapped in bioresorbable pellets working at a percolating regime after subcutaneous implantation in rats, the peptide was slowly released despite the complexation with plasma proteins. However only a very small part of the peptide was found in blood, this small part being still large enough to cause a detectable increase of the circulating growth hormone concentration. Attempts made to increase the solubility of the peptide in plasma were successful when the peptide was combined with arginine, an amino acid known to promote the poor hormonal activity of injected GRF(1-29)NH2 solutions under clinical conditions.

  12. Remote Sensing of Icy Galilean Moon Surface and Atmospheric Composition Using Low Energy (1 eV-4 keV) Neutral Atom Imaging

    NASA Technical Reports Server (NTRS)

    Collier, M. R.; Sittler, E.; Chornay, D.; Cooper, J. F.; Coplan, M.; Johnson, R. E.

    2004-01-01

    We describe a low energy neutral atom imager suitable for composition measurements Europa and other icy Galilean moons in the Jovian magnetosphere. This instrument employs conversion surface technology and is sensitive to either neutrals converted to negative ions, neutrals converted to positive ions and the positive ions themselves depending on the power supply. On a mission such as the Jupiter Icy Moons Orbiter (JIMO), two back-to-back sensors would be flown with separate power supplies fitted to the neutral atom and iodneutral atom sides. This will allow both remote imaging of 1 eV < E < 4 keV neutrals from icy moon surfaces and atmospheres, and in situ measurements of ions at similar energies in the moon ionospheres and Jovian magnetospheric plasma. The instrument provides composition measurements of the neutrals and ions that enter the spectrometer with a mass resolution dependent on the time-of-flight subsystem and capable of resolving molecules. The lower energy neutrals, up to tens of eV, arise from atoms and molecules sputtered off the moon surfaces and out of the moon atmospheres by impacts of more energetic (keV to MeV) ions from the magnetosphere. Direct Simulation Monte Carlo (DSMC) models are used to convert measured neutral abundances to compositional distributions of primary and trace species in the sputtered surfaces and atmospheres. The escaping neutrals can also be detected as ions after photo- or plasma-ionization and pickup. Higher energy, keV neutrals come from charge exchange of magnetospheric ions in the moon atmospheres and provide information on atmospheric structure. At the jovicentric orbits of the icy moons the presence of toroidal gas clouds, as detected at Europa's orbit, provide M e r opportunities to analyze both the composition of neutrals and ions originating from the moon surfaces, and the characteristics of magnetospheric ions interacting with neutral cloud material. Charge exchange of low energy ions near the moons, and directional distributions of the resultant neutrals, allow indirect global mapping of magnetic field structures around the moons. Temporal variation of the magnetic structures can be linked to induced magnetic fields associated with subsurface oceans.

  13. Direct contra naïve-indirect comparison of clinical failure rates between high-viscosity GIC and conventional amalgam restorations: an empirical study.

    PubMed

    Mickenautsch, Steffen; Yengopal, Veerasamy

    2013-01-01

    Naïve-indirect comparisons are comparisons between competing clinical interventions' evidence from separate (uncontrolled) trials. Direct comparisons are comparisons within randomised control trials (RCTs). The objective of this empirical study is to test the null-hypothesis that trends and performance differences inferred from naïve-indirect comparisons and from direct comparisons/RCTs regarding the failure rates of amalgam and direct high-viscosity glass-ionomer cement (HVGIC) restorations in permanent posterior teeth have similar direction and magnitude. A total of 896 citations were identified through systematic literature search. From these, ten and two uncontrolled clinical longitudinal studies for HVGIC and amalgam, respectively, were included for naïve-indirect comparison and could be matched with three out twenty RCTs. Summary effects sizes were computed as Odds ratios (OR; 95% Confidence intervals) and compared with those from RCTs. Trend directions were inferred from 95% Confidence interval overlaps and direction of point estimates; magnitudes of performance differences were inferred from the median point estimates (OR) with 25% and 75% percentile range, for both types of comparison. Mann-Whitney U test was applied to test for statistically significant differences between point estimates of both comparison types. Trends and performance differences inferred from naïve-indirect comparison based on evidence from uncontrolled clinical longitudinal studies and from direct comparisons based on RCT evidence are not the same. The distributions of the point estimates differed significantly for both comparison types (Mann-Whitney U  =  25, n(indirect)  =  26; n(direct)  =  8; p  =  0.0013, two-tailed). The null-hypothesis was rejected. Trends and performance differences inferred from either comparison between HVGIC and amalgam restorations failure rates in permanent posterior teeth are not the same. It is recommended that clinical practice guidance regarding HVGICs should rest on direct comparisons via RCTs and not on naïve-indirect comparisons based on uncontrolled longitudinal studies in order to avoid inflation of effect estimates.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Cheng-hu; Cao, Guo-Fan; Jiang, Qin, E-mail: Jqin710@vip.sina.com

    Highlights: Black-Right-Pointing-Pointer TNF-{alpha} induces MMP-9 expression and secretion to promote RPE cell migration. Black-Right-Pointing-Pointer MAPK activation is not critical for TNF-{alpha}-induced MMP-9 expression. Black-Right-Pointing-Pointer Akt and mTORC1 signaling mediate TNF-{alpha}-induced MMP-9 expression. Black-Right-Pointing-Pointer SIN1 knockdown showed no significant effect on MMP-9 expression by TNF-{alpha}. -- Abstract: Tumor necrosis factor-alpha (TNF-{alpha}) promotes in vitro retinal pigment epithelial (RPE) cell migration to initiate proliferative vitreoretinopathy (PVR). Here we report that TNF-{alpha} promotes human RPE cell migration by inducing matrix metallopeptidase 9 (MMP-9) expression. Inhibition of MMP-9 by its inhibitor or its neutralizing antibody inhibited TNF-{alpha}-induced in vitro RPE cell migration. Reversely, exogenously-addedmore » active MMP-9 promoted RPE cell migration. Suppression Akt/mTOR complex 1(mTORC1) activation by LY 294002 and rapamycin inhibited TNF-{alpha}-mediated MMP-9 expression. To introduce a constitutively active Akt (CA-Akt) in cultured RPE cells increased MMP-9 expression, and to block mTORC1 activation by rapamycin inhibited its effect. RNA interference (RNAi)-mediated silencing of SIN1, a key component of mTOR complex 2 (mTORC2), had no effect on MMP-9 expression or secretion. In conclusion, this study suggest that TNF-{alpha} promotes RPE cell migration by inducing MMP-9 expression through activation of Akt/ mTORC1, but not mTORC2 signaling.« less

  15. 21 CFR 876.5160 - Urological clamp for males.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urological clamp for males. 876.5160 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5160 Urological clamp for males. (a) Identification. A urological clamp for males is a device used to close the urethra of a male to...

  16. Experimental Modal Analysis of Rectangular and Circular Beams

    ERIC Educational Resources Information Center

    Emory, Benjamin H.; Zhu, Wei Dong

    2006-01-01

    Analytical and experimental methods are used to determine the natural frequencies and mode shapes of Aluminum 6061-T651 beams with rectangular and circular cross-sections. A unique test stand is developed to provide the rectangular beam with different boundary conditions including clamped-free, clamped-clamped, clamped-pinned, and pinned-pinned.…

  17. Solutions for transients in arbitrarily branching cables: III. Voltage clamp problems.

    PubMed

    Major, G

    1993-07-01

    Branched cable voltage recording and voltage clamp analytical solutions derived in two previous papers are used to explore practical issues concerning voltage clamp. Single exponentials can be fitted reasonably well to the decay phase of clamped synaptic currents, although they contain many underlying components. The effective time constant depends on the fit interval. The smoothing effects on synaptic clamp currents of dendritic cables and series resistance are explored with a single cylinder + soma model, for inputs with different time courses. "Soma" and "cable" charging currents cannot be separated easily when the soma is much smaller than the dendrites. Subtractive soma capacitance compensation and series resistance compensation are discussed. In a hippocampal CA1 pyramidal neurone model, voltage control at most dendritic sites is extremely poor. Parameter dependencies are illustrated. The effects of series resistance compound those of dendritic cables and depend on the "effective capacitance" of the cell. Plausible combinations of parameters can cause order-of-magnitude distortions to clamp current waveform measures of simulated Schaeffer collateral inputs. These voltage clamp problems are unlikely to be solved by the use of switch clamp methods.

  18. Dynamic analysis of clamp band joint system subjected to axial vibration

    NASA Astrophysics Data System (ADS)

    Qin, Z. Y.; Yan, S. Z.; Chu, F. L.

    2010-10-01

    Clamp band joints are commonly used for connecting circular components together in industry. Some of the systems jointed by clamp band are subjected to dynamic load. However, very little research on the dynamic characteristics for this kind of joint can be found in the literature. In this paper, a dynamic model for clamp band joint system is developed. Contact and frictional slip between the components are accommodated in this model. Nonlinear finite element analysis is conducted to identify the model parameters. Then static experiments are carried out on a scaled model of the clamp band joint to validate the joint model. Finally, the model is adopted to study the dynamic characteristics of the clamp band joint system subjected to axial harmonic excitation and the effects of the wedge angle of the clamp band joint and the preload on the response. The model proposed in this paper can represent the nonlinearity of the clamp band joint and be used conveniently to investigate the effects of the structural and loading parameters on the dynamic characteristics of this type of joint system.

  19. Crystal structure of a 3B3 variant - A broadly neutralizing HIV-1 scFv antibody

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, K. Reed; Walsh, Scott T.R.; NCH)

    2009-12-10

    We present the crystal structure determination of an anti-HIV-1 gp120 single-chain variable fragment antibody variant, 3B3, at 2.5 {angstrom} resolution. This 3B3 variant was derived from the b12 antibody, using phage display and site-directed mutagenesis of the variable heavy chain (V{sub H}) complementary-determining regions (CDRs). 3B3 exhibits enhanced binding affinity and neutralization activity against several cross-clade primary isolates of HIV-1 by interaction with the recessed CD4-binding site on the gp120 envelope protein. Comparison with the structures of the unbound and bound forms of b12, the 3B3 structure closely resembles these structures with minimal differences with two notable exceptions. First, theremore » is a reorientation of the CDR-H3 of the V{sub H} domain where the primary sequences evolved from b12 to 3B3. The structural changes in CDR-H3 of 3B3, in light of the b12-gp120 complex structure, allow for positioning an additional Trp side chain in the binding interface with gp120. Finally, the second region of structural change involves two peptide bond flips in CDR-L3 of the variable light (VL) domain triggered by a point mutation in CDR-H3 of Q100eY resulting in changes in the intramolecular hydrogen bonding patterning between the VL and VH domains. Thus, the enhanced binding affinities and neutralization capabilities of 3B3 relative to b12 probably result from higher hydrophobic driving potential by burying more aromatic residues at the 3B3-gp120 interface and by indirect stabilization of intramolecular contacts of the core framework residues between the VL and VH domains possibly through more favorable entropic effect through the expulsion of water.« less

  20. Application of active electrode compensation to perform continuous voltage-clamp recordings with sharp microelectrodes.

    PubMed

    Gómez-González, J F; Destexhe, A; Bal, T

    2014-10-01

    Electrophysiological recordings of single neurons in brain tissues are very common in neuroscience. Glass microelectrodes filled with an electrolyte are used to impale the cell membrane in order to record the membrane potential or to inject current. Their high resistance induces a high voltage drop when passing current and it is essential to correct the voltage measurements. In particular, for voltage clamping, the traditional alternatives are two-electrode voltage-clamp technique or discontinuous single electrode voltage-clamp (dSEVC). Nevertheless, it is generally difficult to impale two electrodes in a same neuron and the switching frequency is limited to low frequencies in the case of dSEVC. We present a novel fully computer-implemented alternative to perform continuous voltage-clamp recordings with a single sharp-electrode. To reach such voltage-clamp recordings, we combine an active electrode compensation algorithm (AEC) with a digital controller (AECVC). We applied two types of control-systems: a linear controller (proportional plus integrative controller) and a model-based controller (optimal control). We compared the performance of the two methods to dSEVC using a dynamic model cell and experiments in brain slices. The AECVC method provides an entirely digital method to perform continuous recording and smooth switching between voltage-clamp, current clamp or dynamic-clamp configurations without introducing artifacts.

  1. Comparison of direct and indirect methods for assessing leaf area index across a tropical rain forest landscape

    Treesearch

    Paulo C. Olivas; Steven F. Oberbauer; David B. Clark; Deborah A. Clark; Michael G. Ryan; Joseph J. O' Brien; Harlyn Ordonez

    2013-01-01

    Many functional properties of forests depend on the leaf area; however, measuring leaf area is not trivial in tall evergreen vegetation. As a result, leaf area is generally estimated indirectly by light absorption methods. These indirect methods are widely used, but have never been calibrated against direct measurements in tropical rain forests, either at point or...

  2. Distributions-per-level: a means of testing level detectors and models of patch-clamp data.

    PubMed

    Schröder, I; Huth, T; Suitchmezian, V; Jarosik, J; Schnell, S; Hansen, U P

    2004-01-01

    Level or jump detectors generate the reconstructed time series from a noisy record of patch-clamp current. The reconstructed time series is used to create dwell-time histograms for the kinetic analysis of the Markov model of the investigated ion channel. It is shown here that some additional lines in the software of such a detector can provide a powerful new means of patch-clamp analysis. For each current level that can be recognized by the detector, an array is declared. The new software assigns every data point of the original time series to the array that belongs to the actual state of the detector. From the data sets in these arrays distributions-per-level are generated. Simulated and experimental time series analyzed by Hinkley detectors are used to demonstrate the benefits of these distributions-per-level. First, they can serve as a test of the reliability of jump and level detectors. Second, they can reveal beta distributions as resulting from fast gating that would usually be hidden in the overall amplitude histogram. Probably the most valuable feature is that the malfunctions of the Hinkley detectors turn out to depend on the Markov model of the ion channel. Thus, the errors revealed by the distributions-per-level can be used to distinguish between different putative Markov models of the measured time series.

  3. Decoupling the direct and indirect effects of climate on plant litter decomposition: Accounting for stress-induced modifications in plant chemistry.

    PubMed

    Suseela, Vidya; Tharayil, Nishanth

    2018-04-01

    Decomposition of plant litter is a fundamental ecosystem process that can act as a feedback to climate change by simultaneously influencing both the productivity of ecosystems and the flux of carbon dioxide from the soil. The influence of climate on decomposition from a postsenescence perspective is relatively well known; in particular, climate is known to regulate the rate of litter decomposition via its direct influence on the reaction kinetics and microbial physiology on processes downstream of tissue senescence. Climate can alter plant metabolism during the formative stage of tissues and could shape the final chemical composition of plant litter that is available for decomposition, and thus indirectly influence decomposition; however, these indirect effects are relatively poorly understood. Climatic stress disrupts cellular homeostasis in plants and results in the reprogramming of primary and secondary metabolic pathways, which leads to changes in the quantity, composition, and organization of small molecules and recalcitrant heteropolymers, including lignins, tannins, suberins, and cuticle within the plant tissue matrix. Furthermore, by regulating metabolism during tissue senescence, climate influences the resorption of nutrients from senescing tissues. Thus, the final chemical composition of plant litter that forms the substrate of decomposition is a combined product of presenescence physiological processes through the production and resorption of metabolites. The changes in quantity, composition, and localization of the molecular construct of the litter could enhance or hinder tissue decomposition and soil nutrient cycling by altering the recalcitrance of the lignocellulose matrix, the composition of microbial communities, and the activity of microbial exo-enzymes via various complexation reactions. Also, the climate-induced changes in the molecular composition of litter could differentially influence litter decomposition and soil nutrient cycling. Compared with temperate ecosystems, the indirect effects of climate on litter decomposition in the tropics are not well understood, which underscores the need to conduct additional studies in tropical biomes. We also emphasize the need to focus on how climatic stress affects the root chemistry as roots contribute significantly to biogeochemical cycling, and on utilizing more robust analytical approaches to capture the molecular composition of tissue matrix that fuel microbial metabolism. © 2017 John Wiley & Sons Ltd.

  4. Sex Attracts: Investigating Individual Differences in Attentional Bias to Sexual Stimuli

    PubMed Central

    Kagerer, Sabine; Wehrum, Sina; Klucken, Tim; Walter, Bertram; Vaitl, Dieter; Stark, Rudolf

    2014-01-01

    We investigated the impact of sexual stimuli and the influence of sexual motivation on the performance in a dot-probe task and a line-orientation task in a large sample of males and females. All pictures (neutral, erotic) were rated on the dimensions of valence, arousal, disgust, and sexual arousal. Additionally, questionnaires measuring sexual interest/desire/motivation were employed. The ratings of the sexual stimuli point to a successful picture selection because sexual arousal did not differ between the sexes. The stimuli were equally arousing for men and women. Higher scores in the employed questionnaires measuring sexual interest/desire/motivation led to higher sexual arousal ratings of the sex pictures. Attentional bias towards sex pictures was observed in both experimental tasks. The attentional biases measured by the dot-probe and the line-orientation task were moderately intercorrelated suggesting attentional bias as a possible marker for a sex-attention trait. Finally, only the sexual sensation seeking score correlated with the attentional biases of the two tasks. Future research is needed to increase the predictive power of these indirect measures of sexual interest. PMID:25238545

  5. Electrophysiological characterization of synaptic connections between layer VI cortical cells and neurons of the nucleus reticularis thalami in juvenile rats.

    PubMed

    Gentet, Luc J; Ulrich, Daniel

    2004-02-01

    Corticothalamic (CT) feedback projections to the thalamus outnumber sensory inputs from the periphery by orders of magnitude. However, their functional role remains elusive. CT projections may directly excite thalamic relay cells or indirectly inhibit them via excitation of the nucleus reticularis thalami (nRT), a nuclear formation composed entirely of gamma-aminobutyric acidergic neurons. The relative strengths of these two pathways will ultimately control the effects of CT projections on the output of thalamic relay cells. However, corticoreticular synapses have not yet been fully physiologically characterized. Here, local stimulation of layer VI cells by focal application of K+ or AMPA elicited excitatory postsynaptic potentials in nRT neurons with a mean peak amplitude of 2.4 +/- 0.1 mV (n = 75, mean +/- SEM), a mean rise time (10-90%) of 0.74 +/- 0.03 ms and a weighted decay time constant of 11 +/- 0.3 ms. A pharmacological profile of responses was drawn in both current-clamp and voltage-clamp modes, showing the presence of a small N-methyl-d-aspartate receptor-dependent component at depolarized potentials. In two pairs of synaptically coupled layer VI cell-nRT neuron, moderate rates of transmission failures were observed while the latencies were above 5 ms in both cases. Our results indicate that the corticoreticular pathway fulfills the criteria for 'modulatory' inputs and is temporally restricted. We suggest that it may be involved in coincidence detection of convergent corticoreticular signals.

  6. Density functional theory study of direct and indirect photodegradation mechanisms of sulfameter.

    PubMed

    Shah, Shaheen; Hao, Ce

    2016-10-01

    Sulfonamide antibiotics (SAs) have been observed to undergo direct and indirect photodegradation in natural water environments. In this study, the density functional theory (DFT) method was employed for the study of direct and indirect photodegradation mechanisms of sulfameter (SME) with excited triplet states of dissolved organic matter ((3)DOM(*)) and metal ions. SME was adopted as a representative of SAs, and SO2 extrusion product was obtained with different energy paths in the triplet-sensitized photodegradation of the neutral (SME(0)) and the anionic (SME(-)) form of SME. The selected divalent metal ions (Ca(2+), Mg(2+), and Zn(2+)) promoted the triplet-sensitized photodegradation of SME(0) but showed an inhibitory effect in triplet-sensitized photodegradation of SME(-). The triplet-sensitized indirect photodegradation mechanism of SME was investigated with the three DOM analogues, i.e., 2-acetonaphthone (2-AN), fluorenone (FN), and thioxanthone (TN). Results indicated that the selected DOM analogues are highly responsible for the photodegradation via attacking on amine moiety of SME. According to the natural bond orbital (NBO) analysis, the triplet-sensitized photodegradation mechanism of SME(0) with 2-AN, FN, and TN was H-transfer, and the SME(-) was proton plus electron transfer with these DOM analogues.

  7. Validation and use of an indirect enzyme-linked immunosorbent assay for detection of antibodies to West Nile virus in American Alligators (Alligator mississippiensis) in Florida.

    PubMed

    Jacobson, Elliott R; Johnson, April J; Hernandez, Jorge A; Tucker, Sylvia J; Dupuis, Alan P; Stevens, Robert; Carbonneau, Dwayne; Stark, Lillian

    2005-01-01

    In October 2002, West Nile virus (WNV) was identified in farmed American alligators (Alligator mississippiensis) in Florida showing clinical signs and having microscopic lesions indicative of central nervous system disease. To perform seroepidemiologic studies, an indirect enzyme-linked immunosorbent assay (ELISA) was developed to determine exposure of captive and wild alligators to WNV. To validate the test, a group of WNV-seropositive and -seronegative alligators were identified at the affected farm using hemagglutination inhibition (HAI) and the plaque reduction neutralization test (PRNT). The indirect ELISA utilized a rabbit anti-alligator immunoglobulins polyclonal antibody as the secondary antibody, and inactivated WNV-infected Vero cells were used as the coating antigen. For all samples (n=58), the results of the ELISA were consistent with the HAI and PRNT findings. Plasma was collected from 669 free-ranging alligators from 21 sites across Florida in April and October 2003. Four samples collected in April and six in October were positive for WNV antibodies using HAI, PRNT, and the indirect ELISA. This indicated that wild alligators in Florida have been exposed to WNV. These findings can be used as a baseline for future surveys.

  8. Dynamic characterization of contact interactions of micro-robotic leg structures

    NASA Astrophysics Data System (ADS)

    Ryou, Jeong Hoon; Oldham, Kenn Richard

    2014-05-01

    Contact dynamics of microelectromechanical systems (MEMS) are typically complicated and it is consequently difficult to model all dynamic characteristics observed in time-domain responses involving impact. This issue becomes worse when a device, such as a mobile micro-robot, is not clamped to a substrate and has a complex mechanical structure. To characterize such a contact interaction situation, two walking micro-robot prototypes are tested having intentionally simple structures with different dimensions (21.2 mm × 16.3 mm × 0.75 mm and 32 mm × 25.4 mm × 4.1 mm) and weights (0.16 and 2.7 g). Contact interaction behaviors are characterized by analyzing experimental data under various excitation signals. A numerical approach was used to derive a novel contact model consisting of a coefficient of restitution matrix that uses modal vibration information. Experimental validation of the simulation model shows that it captures various dynamic features of the contact interaction when simulating leg behavior more accurately than previous contact models, such as single-point coefficient of restitution or compliant ground models. In addition, this paper shows that small-scale forces can be added to the simulation to improve model accuracy, resulting in average errors across driving conditions on the order of 2-6% for bounce frequency, maximum foot height, and average foot height, although there is substantial variation from case to case.

  9. Estimates of electronic coupling for excess electron transfer in DNA

    NASA Astrophysics Data System (ADS)

    Voityuk, Alexander A.

    2005-07-01

    Electronic coupling Vda is one of the key parameters that determine the rate of charge transfer through DNA. While there have been several computational studies of Vda for hole transfer, estimates of electronic couplings for excess electron transfer (ET) in DNA remain unavailable. In the paper, an efficient strategy is established for calculating the ET matrix elements between base pairs in a π stack. Two approaches are considered. First, we employ the diabatic-state (DS) method in which donor and acceptor are represented with radical anions of the canonical base pairs adenine-thymine (AT) and guanine-cytosine (GC). In this approach, similar values of Vda are obtained with the standard 6-31G* and extended 6-31++G** basis sets. Second, the electronic couplings are derived from lowest unoccupied molecular orbitals (LUMOs) of neutral systems by using the generalized Mulliken-Hush or fragment charge methods. Because the radical-anion states of AT and GC are well reproduced by LUMOs of the neutral base pairs calculated without diffuse functions, the estimated values of Vda are in good agreement with the couplings obtained for radical-anion states using the DS method. However, when the calculation of a neutral stack is carried out with diffuse functions, LUMOs of the system exhibit the dipole-bound character and cannot be used for estimating electronic couplings. Our calculations suggest that the ET matrix elements Vda for models containing intrastrand thymine and cytosine bases are essentially larger than the couplings in complexes with interstrand pyrimidine bases. The matrix elements for excess electron transfer are found to be considerably smaller than the corresponding values for hole transfer and to be very responsive to structural changes in a DNA stack.

  10. Removal of phosphonates from industrial wastewater with UV/FeII, Fenton and UV/Fenton treatment.

    PubMed

    Rott, Eduard; Minke, Ralf; Bali, Ulusoy; Steinmetz, Heidrun

    2017-10-01

    Phosphonates are an important group of phosphorus-containing compounds due to their increasing industrial use and possible eutrophication potential. This study involves investigations into the methods UV/Fe II , Fenton and UV/Fenton for their removal from a pure water matrix and industrial wastewaters. It could be shown that the degradability of phosphonates by UV/Fe II (6 kWh/m 3 ) in pure water crucially depended on the pH and was higher the less phosphonate groups a phosphonate contains. The UV/Fe II method is recommended in particular for the treatment of concentrates with nitrogen-free phosphonates, only little turbidity and a low content of organic compounds. Using Fenton reagent, the degradation of polyphosphonates was relatively weak in a pure water matrix (<20% transformation to o-PO 4 3- ). By means of the Photo-Fenton method (6 kWh/m 3 ), those phosphonates with the smallest numbers of phosphonate groups were easier degraded as well at pH 3.5 in a pure water matrix (o-PO 4 3- formation rates of up to 80%). Despite an incomplete transformation of organically bound phosphorus to o-PO 4 3- with Fenton reagent in an organically highly polluted wastewater (max. 15%), an almost total removal of the total P occurred. The most efficient total P elimination rates were achieved in accordance with the following Fenton implementation: reaction → sludge separation (acidic) → neutralization of the supernatant → sludge separation (neutral). Accordingly, a neutralization directly after the reaction phase led to a lower total P removal extent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Optimal Surgical Therapy in a Porcine (Sus scrofa) Model of Extra-Thoracic Penetrating Trauma Resulting in Hemorrhagic Shock: ED Thoracotomy vs. Immediate Trans-Abdominal Vascular Control. A Porcine Model for Evaluating the Management of Non-Compressible Torso Hemorrhage

    DTIC Science & Technology

    2010-11-08

    celiac aortic clamping (n=6), direct vascular control (n=6), and endovascular aortic occlusion n=6). This study presents a large animal model of class...including thoracic aortic clamping, supra- celiac aortic clamping, direct vascular control, and proximal endovascular balloon occlusion. Following vascular...subsequently underwent non-compressible hemorrhage with thoracic aortic clamping (n=6), supra- celiac aortic clamping (n=6), direct vascular control (n=6

  12. Device for remote operation of electrical disconnect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coleman, Jody Rustyn; Bobbitt, III, John Thomas

    Provided is a device for remote operation of an electrical disconnect. The device can include a handle clamp configured to be secured to an extending member of the electrical disconnect. The device can further include a case clamp configured to be secured to a rigid portion of the electrical disconnect. The device can further include a cable having an exterior sheath coaxially surrounding an inner cable. The inner cable can be coaxially slidable with respect to the exterior sheath. The inner cable can extend through an opening of the case clamp and be secured to the handle clamp. The devicemore » can further include an actuator configured to coaxially slide the inner cable such that the handle clamp is actuated towards the case clamp.« less

  13. Dipeptide-based polyphosphazene and polyester blends for bone tissue engineering.

    PubMed

    Deng, Meng; Nair, Lakshmi S; Nukavarapu, Syam P; Jiang, Tao; Kanner, William A; Li, Xudong; Kumbar, Sangamesh G; Weikel, Arlin L; Krogman, Nicholas R; Allcock, Harry R; Laurencin, Cato T

    2010-06-01

    Polyphosphazene-polyester blends are attractive materials for bone tissue engineering applications due to their controllable degradation pattern with non-toxic and neutral pH degradation products. In our ongoing quest for an ideal completely miscible polyphosphazene-polyester blend system, we report synthesis and characterization of a mixed-substituent biodegradable polyphosphazene poly[(glycine ethyl glycinato)(1)(phenyl phenoxy)(1)phosphazene] (PNGEG/PhPh) and its blends with a polyester. Two dipeptide-based blends namely 25:75 (Matrix1) and 50:50 (Matrix2) were produced at two different weight ratios of PNGEG/PhPh to poly(lactic acid-glycolic acid) (PLAGA). Blend miscibility was confirmed by differential scanning calorimetry, Fourier transform infrared spectroscopy, and scanning electron microscopy. Both blends resulted in higher tensile modulus and strength than the polyester. The blends showed a degradation rate in the order of Matrix2

  14. A new design of indirectly heated cathode based strip type electron gun.

    PubMed

    Maiti, Namita; Lijeesh, K; Barve, U D; Quadri, Nishad; Tembhare, G U; Mukherjee, S; Thakur, K B; Das, A K

    2013-08-01

    A new design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The design issue addressed is the uniformity of temperature on the solid cathode using (a) a multi-segmented filament with variable height as the primary heat source and (b) trapezoidal shaped single long filament as the primary heat source. The proposed design in this paper is based on computer simulation and validated by extensive experimentations. The design emphasis is on maintaining uniform temperature on the solid cathode. The designed multi-segment filament and the single long filament provide a temperature uniformity on the solid cathode of about 250 K and 110 K, respectively. The better temperature uniformity inspite of the thermal expansion, in case of a single long filament tightly clamped at two ends, has been possible due to shaping of the single filament with a number of constituent sections such that the thermal expansion of different sections forming the actual filament takes care of not only the mechanical stability but also does not affect the emitting surface of the filament. Experiments show that the modified design achieves a one to one correspondence of the solid cathode length and the electron beam length emitted from the solid cathode.

  15. Ligase Detection Reaction for the Analysis of Point Mutations using Free Solution Conjugate Electrophoresis in a Polymer Microfluidic Device

    PubMed Central

    Sinville, Rondedrick; Coyne, Jennifer; Meagher, Robert J.; Cheng, Yu-Wei; Barany, Francis; Barron, Annelise; Soper, Steven A.

    2010-01-01

    We have developed a new method for the analysis of low abundant point mutations in genomic DNA using a combination of an allele-specific ligase detection reaction (LDR) with free-solution conjugate electrophoresis (FSCE) to generate and analyze the genetic products. FSCE eliminates the need for a polymer sieving matrix by conjugating chemically synthesized polyamide “drag-tags” onto the LDR primers. The additional drag of the charge-neutral drag-tag breaks the linear scaling of the charge-to-friction ratio of DNA and enables size-based separations of DNA in free solution using electrophoresis with no sieving matrix. We successfully demonstrate the conjugation of polyamide drag-tags onto a set of four LDR primers designed to probe the K-ras oncogene for mutations highly associated with colorectal cancer, the simultaneous generation of fluorescently-labeled LDR/drag-tagged (LDR-dt) products in a multiplexed, single-tube format with mutant:wild-type ratios as low as 1:100, respectively, and the single-base, high-resolution separation of all four LDR-dt products. Separations were conducted in free solution with no polymer network using both a commercial capillary array electrophoresis (CAE) system and a poly(methylmethacrylate), PMMA, microchip replicated via hot-embossing with only a Tris-based running buffer containing additives to suppress the electroosmotic flow (EOF). Typical analysis times for LDR-dt conjugates were 11 min using the CAE system and as low as 85 s for the PMMA microchips. With resolution comparable to traditional gel-based CAE, FSCE along with microchip electrophoresis decreased the separation time by more than a factor of 40. PMID:19053073

  16. Measurement of argon neutral velocity distribution functions near an absorbing boundary in a plasma

    NASA Astrophysics Data System (ADS)

    Short, Zachary; Thompson, Derek; Good, Timothy; Scime, Earl

    2016-10-01

    Neutral particle distributions are critical to the study of plasma boundary interactions, where ion-neutral collisions, e.g. via charge exchange, may modify energetic particle populations impacting the boundary surface. Neutral particle behavior at absorbing boundaries thus underlies a number of important plasma physics issues, such as wall loading in fusion devices and anomalous erosion in Hall thruster channels. Neutral velocity distribution functions (NVDFs) are measured using laser-induced fluorescence (LIF). Our LIF scheme excites the 1s4 non-metastable state of neutral argon with 667.913 nm photons. The subsequent decay emission at 750.590 nm is recorded synchronously with injection laser frequency. Measurements are performed near a grounded boundary immersed in a cylindrical helicon plasma, with the boundary plate oriented at an oblique angle to the magnetic field. NVDFs are recorded in multiple velocity dimensions and in a three-dimensional volume, enabling point-to-point comparisons with NVDF predictions from particle-in-cell models as well as comparisons with ion velocity distribution function measurements obtained in the same regions through Ar-II LIF. This work is supported by US National Science Foundation Grant Number PHYS-1360278.

  17. Positive, negative, or all relative? Evaluative conditioning of ambivalence.

    PubMed

    Glaser, Tina; Woud, Marcella L; Labib Iskander, Michael; Schmalenstroth, Vera; Vo, Thuy My

    2018-04-01

    In evaluative conditioning (EC), the pairing of a positively or negatively valenced stimulus (US) with a neutral stimulus (CS) leads to a corresponding change in liking of the CS. EC research so far has concentrated on using unambiguously positive or negative USs. However, attitude objects are often ambivalent, i.e., can simultaneously possess positive and negative features. The present research investigated whether ambivalence can be evaluatively conditioned and whether contingency awareness moderates this effect. In two studies, positive, negative, neutral, and ambivalent USs were paired with affectively neutral CSs. Results showed standard EC effects that were moderated by contingency awareness. Most interestingly, EC effects were also obtained for the ambivalent USs, indicating that ambivalence can indeed be conditioned. However, contingency awareness seemed to play a lesser role in ambivalence conditioning. Ambivalence EC effects were obtained on subjective and objective direct measures of ambivalence as well as on a more indirect measure. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Egg yolk antibodies for detection and neutralization of Clostridium botulinum type A neurotoxin.

    PubMed

    Trott, D L; Yang, M; Gonzalez, J; Larson, A E; Tepp, W H; Johnson, E A; Cook, M E

    2009-05-01

    The objective of this research project was to determine the usefulness of an egg antibody platform for producing materials for the detection and neutralization of botulinum type A neurotoxin. Yield estimates for detection and neutralizing antibodies produced using methods described were calculated. Antibody specific to botulinum toxoid A (aToxoid) and toxin A (aBoNT/A) was produced by immunizing hens with botulinum toxoid A (toxoid) followed by increasing amounts of botulinum neurotoxin A (BoNT/A) in Freund incomplete adjuvant. Egg yolks were extracted with polyethylene glycol (PEG) for antibody detection and neutralization experiments. A model aToxoid/toxoid immunoassay using only egg yolk antibody was developed and had a detection limit of 1 pg/ml of toxoid. In an indirect enzyme-linked immunosorbent assay of BoNT/A-specific antibody, the aBoNT/A contained more BoNT/A-specific antibody than did the aToxoid, and aBoNT/A was as effective as commercial rabbit antibody. The aToxoid provided no protection against BoNT/A in a standard mouse neutralization assay; however, 1 mg of PEG-extracted aBoNT/A neutralized 4,000 lethal doses of BoNT/A injected intraperitoneally. Based on these results, we calculated that in 1 month one hen could produce more than 100 liters of antibody detection reagents or enough antibody to neutralize approximately 11.6 million mouse lethal doses of botulinum toxin. Utilization of an egg antibody platform is potentially rapid (28 to 70 days) and scalable to kilogram quantities using current egg production facilities with as few as 1,000 hens.

  19. Flight Tests of Various Tail Modifications on the Brewster XSBA-1 Airplane. 3 - Measurements of Flying Qualities with Tail Configuration 3

    DTIC Science & Technology

    1944-07-12

    of tall area tlaes tall length are nearly the same. The airplane eas stable, « tick fixed, In all condi- tions except vave-off *lth the center of...in all conditions •icept aeve.off. A table of neutral points, both stick free end « tick flaed. for the XSBA-1 airplane «1th tall -it.figuration...I follostai Condition Ct Keutral point, Neutral point. • tick fixed •tlek free illding Cruising Cllablnc Landing approach •eve.off C.« 1.0

  20. Contributions of fluid convection and electrical migration to transport in cartilage: relevance to loading.

    PubMed

    Garcia, A M; Frank, E H; Grimshaw, P E; Grodzinsky, A J

    1996-09-15

    We have studied the contributions of diffusion, fluid flow and electrical migration to molecular transport through adult articular cartilage explants using neutral and charged solutes that were either radiolabeled (3H2O, [35S]sulfate, [3H]thymidine, [3H]raffinose, and a synthetic matrix metalloproteinase inhibitor) or fluorescently tagged (NSPA and Lissamine-dextran). In order to induce fluid flow within the cartilage matrix without mechanical deformation, electric current densities were applied across cartilage disks. These currents produced electroosmotic fluid velocities of 1-2 microns/s, magnitudes that have been reported to exist during joint loading in vivo. This fluid convection enhanced neutral solute flux relative to passive diffusion alone by a factor that increased with the size of the solute. While the enhancement factor for 3H2O was 2.3-fold, that for [3H]raffinose (594 Da) and similar sized neutral solutes was 10-fold, suggesting that the effect of fluid flow is important even for small solutes. The largest enhancement (25-fold) was seen for the neutral 10-kDa Lissamine-dextran, confirming that fluid convection is most important for large solutes. We also studied the electrophoretic contribution to solute flux, which is relevant to the presence of intratissue streaming potentials induced during loading in vivo. Using the negatively charged [35S]sulfate ion with a range of current densities, as much as a 10-fold enhancement in flux was observed. Values for the intrinsic transport properties of the solutes (e.g., diffusivity, electrical mobility, hydrodynamic hindrance factor) can be obtained from the data.

  1. Hydrophone Investigations of Earthquakes and Explosion Generated High-Frequency Seismic Phases

    DTIC Science & Technology

    1989-06-30

    stacked along three axes, a temperature sensor , a 2- component tiltmeter , and floating point analog-to-digital electronics. It is clamped inside the... sensors within the ocean- sediment-basement column in order to maximize the signal-to-noise ratio and the signal fidelity of various seismic and acoustic...improved by siting the sensors below the ocean-sediment interface. These changes are especially pronounced on horizontal sensors . Although siting the

  2. Numerical simulations of an elastica pendulum

    NASA Astrophysics Data System (ADS)

    Sinclair, R.

    Folklore would have it that a massless clamped-free elastica undergoing planar motion with a point end mass possesses periodic solutions corresponding to a single mode of oscillation. We present a battery of numerical simulations leading to the single conclusion that these supposed periodic solutions do not exist, due to a strong nonlinear coupling of two modes, the frequency of one of which is apparently inversely proportional to the magnitude of the force acting on the elastica.

  3. A structural and mechanistic study of π-clamp-mediated cysteine perfluoroarylation.

    PubMed

    Dai, Peng; Williams, Jonathan K; Zhang, Chi; Welborn, Matthew; Shepherd, James J; Zhu, Tianyu; Van Voorhis, Troy; Hong, Mei; Pentelute, Bradley L

    2017-08-11

    Natural enzymes use local environments to tune the reactivity of amino acid side chains. In searching for small peptides with similar properties, we discovered a four-residue π-clamp motif (Phe-Cys-Pro-Phe) for regio- and chemoselective arylation of cysteine in ribosomally produced proteins. Here we report mutational, computational, and structural findings directed toward elucidating the molecular factors that drive π-clamp-mediated arylation. We show the significance of a trans conformation prolyl amide bond for the π-clamp reactivity. The π-clamp cysteine arylation reaction enthalpy of activation (ΔH ‡ ) is significantly lower than a non-π-clamp cysteine. Solid-state NMR chemical shifts indicate the prolyl amide bond in the π-clamp motif adopts a 1:1 ratio of the cis and trans conformation, while in the reaction product Pro3 was exclusively in trans. In two structural models of the perfluoroarylated product, distinct interactions at 4.7 Å between Phe1 side chain and perfluoroaryl electrophile moiety are observed. Further, solution 19 F NMR and isothermal titration calorimetry measurements suggest interactions between hydrophobic side chains in a π-clamp mutant and the perfluoroaryl probe. These studies led us to design a π-clamp mutant with an 85-fold rate enhancement. These findings will guide us toward the discovery of small reactive peptides to facilitate abiotic chemistry in water.

  4. Neurotoxicity of Micrurus altirostris (Uruguayan coral snake) venom and its neutralization by commercial coral snake antivenom and specific antiserum raised in rabbits.

    PubMed

    de Abreu, Valdemir Aparecido; Leite, Gildo Bernardo; Oliveira, Caroline Borja; Hyslop, Stephen; Furtado, Maria de Fatima Domingos; Simioni, Lea Rodrigues

    2008-07-01

    In this work, we studied the neuromuscular blockade caused by Micrurus altirostris venom (0.1-10 microg/mL) in indirect stimulated chick biventer cervicis and mouse phrenic nerve-diaphragm preparations and the ability of commercial antivenom (Instituto Butantan) and antiserum raised in rabbits to neutralize neurotoxicity and lethality in chicks and mice (LD(50) 0.042 and 0.255 mg/kg), injected i.m. and i.p., respectively, with venom (5 LD(50)):antivenom or antiserum mixtures (n = 6) of 1:1-1:2.5-1:5-1:10-1:20. The venom caused a complete and irreversible neuromuscular blockade in both preparations, inhibited the acetylcholine and carbachol contractures, without interfering on KCl response. The neuromuscular blockade was not Ca(2+) or temperature-dependent and did not affect the response to direct stimulation. Only a venom:antivenom or antiserum ratio of 1:20 neutralized the neuromuscular blockade in vitro and protected chicks and mice against 5 LD(50) of venom. Our results indicated that Micrurus altirostris venom interferes with postsynaptic neurotransmission and that commercial antivenom and rabbit antiserum have low efficacy in neutralizing the neurotoxicity and lethality of this venom.

  5. Cardiovascular transition at birth: a physiological sequence.

    PubMed

    Hooper, Stuart B; Te Pas, Arjan B; Lang, Justin; van Vonderen, Jeroen J; Roehr, Charles Christoph; Kluckow, Martin; Gill, Andrew W; Wallace, Euan M; Polglase, Graeme R

    2015-05-01

    The transition to newborn life at birth involves major cardiovascular changes that are triggered by lung aeration. These include a large increase in pulmonary blood flow (PBF), which is required for pulmonary gas exchange and to replace umbilical venous return as the source of preload for the left heart. Clamping the umbilical cord before PBF increases reduces venous return and preload for the left heart and thereby reduces cardiac output. Thus, if ventilation onset is delayed following cord clamping, the infant is at risk of superimposing an ischemic insult, due to low cardiac output, on top of an asphyxic insult. Much debate has centered on the timing of cord clamping at birth, focusing mainly on the potential for a time-dependent placental to infant blood transfusion. This has prompted recommendations for delayed cord clamping for a set time after birth in infants not requiring resuscitation. However, recent evidence indicates that ventilation onset before cord clamping mitigates the adverse cardiovascular consequences caused by immediate cord clamping. This indicates that the timing of cord clamping should be based on the infant's physiology rather than an arbitrary period of time and that delayed cord clamping may be of greatest benefit to apneic infants.

  6. Planar patch clamp for neuronal networks--considerations and future perspectives.

    PubMed

    Bosca, Alessandro; Martina, Marzia; Py, Christophe

    2014-01-01

    The patch-clamp technique is generally accepted as the gold standard for studying ion channel activity allowing investigators to either "clamp" membrane voltage and directly measure transmembrane currents through ion channels, or to passively monitor spontaneously occurring intracellular voltage oscillations. However, this resulting high information content comes at a price. The technique is labor-intensive and requires highly trained personnel and expensive equipment. This seriously limits its application as an interrogation tool for drug development. Patch-clamp chips have been developed in the last decade to overcome the tedious manipulations associated with the use of glass pipettes in conventional patch-clamp experiments. In this chapter, we describe some of the main materials and fabrication protocols that have been developed to date for the production of patch-clamp chips. We also present the concept of a patch-clamp chip array providing high resolution patch-clamp recordings from individual cells at multiple sites in a network of communicating neurons. On this chip, the neurons are aligned with the aperture-probes using chemical patterning. In the discussion we review the potential use of this technology for pharmaceutical assays, neuronal physiology and synaptic plasticity studies.

  7. Design and experimental research of a novel inchworm type piezo-driven rotary actuator with the changeable clamping radius.

    PubMed

    Zhao, Hongwei; Fu, Lu; Ren, Luquan; Huang, Hu; Fan, Zunqiang; Li, Jianping; Qu, Han

    2013-01-01

    In this paper, a novel piezo-driven rotary actuator with the changeable clamping radius is developed based on the inchworm principle. This actuator mainly utilizes three piezoelectric actuators, a flexible gripper, a clamping block, and a rotor to achieve large stroke rotation with high resolution. The design process of the flexible gripper consisting of the driving unit and the clamping unit is described. Lever-type mechanisms were used to amplify the micro clamping displacements. The amplifying factor and parasitic displacement of the lever-type mechanism in the clamping unit was analyzed theoretically and experimentally. In order to investigate the rotation characteristics of the actuator, a series of experiments was carried out. Experimental results indicate that the actuator can rotate at a speed of 77,488 μrad/s with a driving frequency of 167 Hz. The rotation resolution and maximum load torque of the actuator are 0.25 μrad and 37 N mm, respectively. The gripper is movable along the z direction based on an elevating platform, and the clamping radius can change from 10.6 mm to 25 mm. Experimental results confirm that the actuator can achieve different rotation speeds by changing the clamping radius.

  8. Assessing the environmental performance of biomass supply chains: Methods, results, challenges and limitations

    Treesearch

    Jorg Schweinle; Anne Rodl; Pal Borjesson; Daniel G. Neary; Johannes W.A. Langeveld; Goran Berndes; Annette Cowie; Serina Ahlgren; Manuele Margni; Caroline Gaudreault; Jake Verschuyl; T. Bently Wigley; Kirsten Vice; Brian Titus

    2015-01-01

    The on-going public debate on sustainability of bioenergy began in 2007 and 2008 after a couple of papers were published questioning the reported N2O emissions caused by cultivation of agricultural crops (Crutzen et al., 2007) and the carbon neutrality of biomass use (Searchinger et al., 2008) due to direct and indirect land use change as well as change of carbon...

  9. [Intraoperative lactic acidosis, can it be treated? Clinico-experimental, prospective, sequential study].

    PubMed

    Pietropaoli, P; Caporelli, S; De Pace, F; Donati, A; Adrario, E; Luzi, A; Munch, C; Giovannini, C; Frezzotti, A R

    1994-12-01

    To verify the efficacy and absence of risk attributable to therapy with alkaline solutions for correction of lactic acidosis and to demonstrate the usefulness of L-carnitine in converting lactate into pyruvate in conditions of good blood oxygenation. Prospective study on a consecutive series of patients subdivided into three groups following the use of: alkalinizing therapy (group I), L-carnitine (group II), or saline solution (group III). Groups 1 and 2 were further subdivided into subgroups "a" and "b" according to the type of alkalinizing agent and of L-carnitine somministration. Teaching Hospital-Torrette di Ancona. 65 patients submitted to major vascular surgery with aortic clamping in the time period between January 1992 and August 1993. During aortic clamping patients of: group I received 2 mEq:kg of bicarbonate or tromentamolo according to the specific subgroup. Group II received a bolus of 2 g of L-carnitine, patients of group IIb received further 2 g of carnitine in continuous perfusion until the end of surgery. Group III received no pharmacological intervention. HR BP, arterial blood gases and lactic acid levels were measured at 12 pre-determined times. Only a neutralizing effect of alkalinizing therapy was observed, whereas the lactic acid measurements demonstrated no significant differences between the different groups. These results confirm the data of other Authors concerning the good compliance of alkalinizing therapy, however, there was demonstrated no clear evidence of its effective usefulness. No metabolic stimulation due to L-canitina could be demonstrated in our experimental conditions.

  10. Clinical aspects of incorporating cord clamping into stabilisation of preterm infants.

    PubMed

    Knol, Ronny; Brouwer, Emma; Vernooij, Alex S N; Klumper, Frans J C M; DeKoninck, Philip; Hooper, Stuart B; Te Pas, Arjan B

    2018-04-21

    Fetal to neonatal transition is characterised by major pulmonary and haemodynamic changes occurring in a short period of time. In the international neonatal resuscitation guidelines, comprehensive recommendations are available on supporting pulmonary transition and delaying clamping of the cord in preterm infants. Recent experimental studies demonstrated that the pulmonary and haemodynamic transition are intimately linked, could influence each other and that the timing of umbilical cord clamping should be incorporated into the respiratory stabilisation. We reviewed the current knowledge on how to incorporate cord clamping into stabilisation of preterm infants and the physiological-based cord clamping (PBCC) approach, with the infant's transitional status as key determinant of timing of cord clamping. This approach could result in optimal timing of cord clamping and has the potential to reduce major morbidities and mortality in preterm infants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Sound absorption by clamped poroelastic plates.

    PubMed

    Aygun, H; Attenborough, K

    2008-09-01

    Measurements and predictions have been made of the absorption coefficient and the surface acoustic impedance of poroelastic plates clamped in a large impedance tube and separated from the rigid termination by an air gap. The measured and predicted absorption coefficient and surface impedance spectra exhibit low frequency peaks. The peak frequencies observed in the absorption coefficient are close to those predicted and measured in the deflection spectra of the clamped poroelastic plates. The influences of the rigidity of the clamping conditions and the width of the air gap have been investigated. Both influences are found to be important. Increasing the rigidity of clamping reduces the low frequency absorption peaks compared with those measured for simply supported plates or plates in an intermediate clamping condition. Results for a closed cell foam plate and for two open cell foam plates made from recycled materials are presented. For identical clamping conditions and width of air gap, the results for the different materials differ as a consequence mainly of their different elasticity, thickness, and cell structure.

  12. Double arch mirror study. Part 1: Preliminary engineering report

    NASA Technical Reports Server (NTRS)

    Vukobratovich, D.; Hillman, D.

    1983-01-01

    In the proposed design, the NASA AMES 20-in double arch mirror is supported by three clamp and flexure assemblies. The mirror clamp consists of a T-shaped Invar-36 member that goes into a similarly shaped socket in the back of the mirror. The mirror socket is made oversize and contacts the clamp only along the conical surface. The clamp is preloaded by a spring washer and pulls the mirror into contact with the flexure. The clamp is then inserted into the mirror socket through a cutout, is rotated 90 deg, and is then pinned in place. Loading conditions considered in socket design are discussed as well as stress in the socket and clamp. Flexure geometry and stress are examined as well as the effects of flexure error and of mirror cell error.

  13. Fabrication and characterization of a piezoelectric energy harvester with clamped-clamped beams

    NASA Astrophysics Data System (ADS)

    Cui, Yan; Yu, Menglin; Gao, Shiqiao; Kong, Xiangxin; Gu, Wang; Zhang, Ran; Liu, Bowen

    2018-05-01

    This work presents a piezoelectric energy harvester with clamped-clamped beams, and it is fabricated with MEMS process. When excited by sinusoidal vibration, the energy harvester has a sharp jumping down phenomenon and the measured frequency responses of the clamped-clamped beams structure show a larger bandwidth which is about 56Hz, more efficient than that with cantilever beams. When the exciting acceleration ac is 12m/s2, the energy harvester achieves to a maximum open-circuit voltage of 94mV on one beam. The load voltage is proportional to the load resistance, and it increased with the increase of load resistance. Connected four beams in series, the output power reaches the maximum value of 730 nW and the optimal load is 15KΩ to one beam.

  14. Indirect immobilized Jagged1 suppresses cell cycle progression and induces odonto/osteogenic differentiation in human dental pulp cells.

    PubMed

    Manokawinchoke, Jeeranan; Nattasit, Praphawi; Thongngam, Tanutchaporn; Pavasant, Prasit; Tompkins, Kevin A; Egusa, Hiroshi; Osathanon, Thanaphum

    2017-08-31

    Notch signaling regulates diverse biological processes in dental pulp tissue. The present study investigated the response of human dental pulp cells (hDPs) to the indirect immobilized Notch ligand Jagged1 in vitro. The indirect immobilized Jagged1 effectively activated Notch signaling in hDPs as confirmed by the upregulation of HES1 and HEY1 expression. Differential gene expression profiling using an RNA sequencing technique revealed that the indirect immobilized Jagged1 upregulated genes were mainly involved in extracellular matrix organization, disease, and signal transduction. Downregulated genes predominantly participated in the cell cycle, DNA replication, and DNA repair. Indirect immobilized Jagged1 significantly reduced cell proliferation, colony forming unit ability, and the number of cells in S phase. Jagged1 treated hDPs exhibited significantly higher ALP enzymatic activity, osteogenic marker gene expression, and mineralization compared with control. Pretreatment with a γ-secretase inhibitor attenuated the Jagged1-induced ALP activity and mineral deposition. NOTCH2 shRNA reduced the Jagged1-induced osteogenic marker gene expression, ALP enzymatic activity, and mineral deposition. In conclusion, indirect immobilized Jagged1 suppresses cell cycle progression and induces the odonto/osteogenic differentiation of hDPs via the canonical Notch signaling pathway.

  15. Rigid clamp

    DOEpatents

    Benavides, G.L.; Burt, J.D.

    1994-07-12

    The invention relates to a clamp mechanism that can be used to attach or temporarily support objects inside of tubular goods. The clamp mechanism can also be modified so that it grips objects. The clamp has a self-centering feature to accommodate out-of-roundness or other internal defections in tubular objects such as pipe. A plurality of clamping shoes are expanded by a linkage which is preferably powered by a motor to contact the inside of a pipe. The motion can be reversed and jaw elements can be connected to the linkage so as to bring the jaws together to grab an object. 12 figs.

  16. Rigid clamp

    DOEpatents

    Benavides, Gilbert L.; Burt, Jack D.

    1994-01-01

    The invention relates to a clamp mechanism that can be used to attach or temporarily support objects inside of tubular goods. The clamp mechanism can also be modified so that it grips objects. The clamp has a self-centering feature to accommodate out-of-roundness or other internal defections in tubular objects such as pipe. A plurality of clamping shoes are expanded by a linkage which is preferably powered by a motor to contact the inside of a pipe. The motion can be reversed and jaw elements can be connected to the linkage so as to bring the jaws together to grab an object.

  17. Advanced motor driven clamped borehole seismic receiver

    DOEpatents

    Engler, Bruce P.; Sleefe, Gerard E.; Striker, Richard P.

    1993-01-01

    A borehole seismic tool including a borehole clamp which only moves perpendicular to the borehole. The clamp is driven by an electric motor, via a right angle drive. When used as a seismic receiver, the tool has a three part housing, two of which are hermetically sealed. Accelerometers or geophones are mounted in one hermetically sealed part, the electric meter in the other hermetically sealed part, and the clamp and right angle drive in the third part. Preferably the tool includes cable connectors at both ends. Optionally a shear plate can be added to the clamp to extend the range of the tool.

  18. Radial wedge flange clamp

    DOEpatents

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  19. Making a Bad Situation Worse: An Invasive Species Altering the Balance of Interactions between Local Species.

    PubMed

    Mello, Thayná Jeremias; Oliveira, Alexandre Adalardo de

    2016-01-01

    Biological invasions pose a significant threat to biodiversity, especially on oceanic islands. One of the primary explanations for the success of plant invaders is direct suppression of competitors. However, indirect interactions can also be important, although they are often overlooked in studies on biological invasion. The shrub Leucaena leucocephala is a widespread island invader with putative allelopathic effects on the germination and growth of other species. We quantified the impact of Leucaena on plant communities richness on an oceanic Brazilian island and, through nursery experiments, investigated the potential for allelopathic effects on the germination of Erythrina velutina, a native species that is often absent from stands of Leucaena. Additionally, in a manipulative field experiment, we examined the direct and indirect effects (mediated by the native species Capparis flexuosa) of the invader on the development of Erythrina. The species richness in invaded sites was lower than in uninvaded sites, and Capparis was the only native species that was frequently present in invaded sites. In the nursery experiments, we found no evidence that Leucaena affects the germination of Erythrina. In the field experiments, the odds of Erythrina germination were lower in the presence of Leucaena litter, but higher in the presence of Leucaena trees. However, the survival and growth of Erythrina were considerably inhibited by the presence of Leucaena trees. The isolated effect of native Capparis on the germination and growth of Erythrina varied from positive to neutral. However, when Capparis and Leucaena were both present, their combined negative effects on Erythrina were worse than the effect of Leucaena alone, which may be attributed to indirect effects. This study provides the first empirical evidence that the balance of the interactions between native species can shift from neutral/positive to negative in the presence of an exotic species.

  20. Totally laparoscopic aortic surgery: comparison of the apron and retrocolic techniques in a porcine model.

    PubMed

    Huynh, Hai; Elkouri, Stephane; Beaudoin, Nathalie; Bruneau, Luc; Guimond, Cathie; Daniel, Véronique; Blair, Jean-François

    2007-01-01

    This study evaluated the learning curve for a second-year general surgery resident and compared 2 totally laparoscopic aortic surgery techniques in 10 pigs: the transretroperitoneal apron approach and the transperitoneal retrocolic approach. Five end points were compared: success rate, percentage of conversion, time required, laparoscopic anastomosis quality, and learning curve. The first 3 interventions required an open conversion. The last 7 were done without complications. Mean dissection time was significantly higher with the apron approach compared with the retrocolic approach. The total times for operation, clamping, and arteriotomy time were similar. All laparoscopic anastomoses were patent and without stenosis. The initial learning curve for laparoscopic anastomosis was relatively short for a second-year surgery resident. Both techniques resulted in satisfactory exposure of the aorta and similar mean operative and clamping time. Training on an ex vivo laparoscopic box trainer and on an animal model seems to be complementary to decrease laparoscopic anastomosis completion time.

  1. The Electrophysiological MEMS Device with Micro Channel Array for Cellular Network Analysis

    NASA Astrophysics Data System (ADS)

    Tonomura, Wataru; Kurashima, Toshiaki; Takayama, Yuzo; Moriguchi, Hiroyuki; Jimbo, Yasuhiko; Konishi, Satoshi

    This paper describes a new type of MCA (Micro Channel Array) for simultaneous multipoint measurement of cellular network. Presented MCA employing the measurement principles of the patch-clamp technique is designed for advanced neural network analysis which has been studied by co-authors using 64ch MEA (Micro Electrode Arrays) system. First of all, sucking and clamping of cells through channels of developed MCA is expected to improve electrophysiological signal detections. Electrophysiological sensing electrodes integrated around individual channels of MCA by using MEMS (Micro Electro Mechanical System) technologies are electrically isolated for simultaneous multipoint measurement. In this study, we tested the developed MCA using the non-cultured rat's cerebral cortical slice and the hippocampal neurons. We could measure the spontaneous action potential of the slice simultaneously at multiple points and culture the neurons on developed MCA. Herein, we describe the experimental results together with the design and fabrication of the electrophysiological MEMS device with MCA for cellular network analysis.

  2. Incorporating nuclear vibrational energies into the "atom in molecules" analysis: An analytical study

    NASA Astrophysics Data System (ADS)

    Gharabaghi, Masumeh; Shahbazian, Shant

    2017-04-01

    The quantum theory of atoms in molecules (QTAIM) is based on the clamped nucleus paradigm and solely working with the electronic wavefunctions, so does not include nuclear vibrations in the AIM analysis. On the other hand, the recently extended version of the QTAIM, called the multi-component QTAIM (MC-QTAIM), incorporates both electrons and quantum nuclei, i.e., those nuclei treated as quantum waves instead of clamped point charges, into the AIM analysis using non-adiabatic wavefunctions. Thus, the MC-QTAIM is the natural framework to incorporate the role of nuclear vibrations into the AIM analysis. In this study, within the context of the MC-QTAIM, the formalism of including nuclear vibrational energy in the atomic basin energy is developed in detail and its contribution is derived analytically using the recently proposed non-adiabatic Hartree product nuclear wavefunction. It is demonstrated that within the context of this wavefunction, the quantum nuclei may be conceived pseudo-adiabatically as quantum oscillators and both isotropic harmonic and anisotropic anharmonic oscillator models are used to compute the zero-point nuclear vibrational energy contribution to the basin energies explicitly. Inspired by the results gained within the context of the MC-QTAIM analysis, a heuristic approach is proposed within the context of the QTAIM to include nuclear vibrational energy in the basin energy from the vibrational wavefunction derived adiabatically. The explicit calculation of the basin contribution of the zero-point vibrational energy using the uncoupled harmonic oscillator model leads to results consistent with those derived from the MC-QTAIM.

  3. Incorporating nuclear vibrational energies into the "atom in molecules" analysis: An analytical study.

    PubMed

    Gharabaghi, Masumeh; Shahbazian, Shant

    2017-04-21

    The quantum theory of atoms in molecules (QTAIM) is based on the clamped nucleus paradigm and solely working with the electronic wavefunctions, so does not include nuclear vibrations in the AIM analysis. On the other hand, the recently extended version of the QTAIM, called the multi-component QTAIM (MC-QTAIM), incorporates both electrons and quantum nuclei, i.e., those nuclei treated as quantum waves instead of clamped point charges, into the AIM analysis using non-adiabatic wavefunctions. Thus, the MC-QTAIM is the natural framework to incorporate the role of nuclear vibrations into the AIM analysis. In this study, within the context of the MC-QTAIM, the formalism of including nuclear vibrational energy in the atomic basin energy is developed in detail and its contribution is derived analytically using the recently proposed non-adiabatic Hartree product nuclear wavefunction. It is demonstrated that within the context of this wavefunction, the quantum nuclei may be conceived pseudo-adiabatically as quantum oscillators and both isotropic harmonic and anisotropic anharmonic oscillator models are used to compute the zero-point nuclear vibrational energy contribution to the basin energies explicitly. Inspired by the results gained within the context of the MC-QTAIM analysis, a heuristic approach is proposed within the context of the QTAIM to include nuclear vibrational energy in the basin energy from the vibrational wavefunction derived adiabatically. The explicit calculation of the basin contribution of the zero-point vibrational energy using the uncoupled harmonic oscillator model leads to results consistent with those derived from the MC-QTAIM.

  4. SevenOperators, a Mathematica script for harmonic oscillator nuclear matrix elements arising in semileptonic electroweak interactions

    NASA Astrophysics Data System (ADS)

    Haxton, Wick; Lunardini, Cecilia

    2008-09-01

    Semi-leptonic electroweak interactions in nuclei—such as β decay, μ capture, charged- and neutral-current neutrino reactions, and electron scattering—are described by a set of multipole operators carrying definite parity and angular momentum, obtained by projection from the underlying nuclear charge and three-current operators. If these nuclear operators are approximated by their one-body forms and expanded in the nucleon velocity through order |p→|/M, where p→ and M are the nucleon momentum and mass, a set of seven multipole operators is obtained. Nuclear structure calculations are often performed in a basis of Slater determinants formed from harmonic oscillator orbitals, a choice that allows translational invariance to be preserved. Harmonic-oscillator single-particle matrix elements of the multipole operators can be evaluated analytically and expressed in terms of finite polynomials in q, where q is the magnitude of the three-momentum transfer. While results for such matrix elements are available in tabular form, with certain restriction on quantum numbers, the task of determining the analytic form of a response function can still be quite tedious, requiring the folding of the tabulated matrix elements with the nuclear density matrix, and subsequent algebra to evaluate products of operators. Here we provide a Mathematica script for generating these matrix elements, which will allow users to carry out all such calculations by symbolic manipulation. This will eliminate the errors that may accompany hand calculations and speed the calculation of electroweak nuclear cross sections and rates. We illustrate the use of the new script by calculating the cross sections for charged- and neutral-current neutrino scattering in 12C. Program summaryProgram title: SevenOperators Catalogue identifier: AEAY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEAY_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 2227 No. of bytes in distributed program, including test data, etc.: 19 382 Distribution format: tar.gz Programming language: Mathematica Computer: Any computer running Mathematica; tested on Mac OS X PowerPC (32-bit) running Mathematica 6.0.0 Operating system: Any running Mathematica RAM: Memory requirements determined by Mathematica; 512 MB or greater RAM and hard drive space of at least 3.0 GB recommended Classification: 17.16, 17.19 Nature of problem: Algebraic evaluation of harmonic oscillator nuclear matrix elements for the one-body multipole operators governing semi-leptonic weak interactions, such as charged- or neutral-current neutrino scattering off nuclei. Solution method: Mathematica evaluation of associated angular momentum algebra and spherical Bessel function radial integrals. Running time: Depends on the complexity of the one-body density matrix employed, but times of a few seconds are typical.

  5. Action of polysaccharides of similar average mass but differing molecular volume and charge on fluid drainage through synovial interstitium in rabbit knees

    PubMed Central

    Scott, D; Coleman, P J; Mason, R M; Levick, J R

    2000-01-01

    Hyaluronan (HA), an anionic polysaccharide of synovial fluid, attenuates fluid loss from joints as joint pressure is raised (‘outflow buffering’). The buffering is thought to depend on the expanded molecular domain of the polymer, which causes reflection by synovial extracellular matrix, leading to flow-dependent concentration polarization. We therefore assessed the effects of polysaccharides of differing average molecular volume and charge. Trans-synovial fluid drainage(Q̇s) was measured at controlled joint fluid pressure (Pj) in knees of anaesthetized rabbits. The joints were infused with polydisperse HA of weight-average mass 2100 kDa (4 mg ml−1, n = 17), with polydisperse neutral dextran of similar average mass (2000 kDa; n = 7) or with Ringer solution vehicle (n = 2). The role of polymer charge was assessed by infusions of neutral or sulphated dextran of average molecular mass 500 kDa (n = 6). When HA was present, Q̇s increased little with pressure, forming a virtual plateau of ∼4 μl min−1 from 10 to 25 cmH2O. Neutral dextran 2000 failed to replicate this effect. Instead, Q̇s increased steeply with Pj, reaching eight times the HA value by 20 cmH2O (P = 0.0001, ANOVA). Dextran 2000 reduced flows in comparison with Ringer solution. Analysis of the aspirated joint fluid showed that 31 ± 0.07 % (s.e.m.) of dextran 2000 in the filtrand was reflected by synovium, compared with ≥ 79 % for HA. The viscometric molecular radius of the dextran, ∼31 nm, was smaller than that of HA (101–181 nm), as was its osmotic pressure. Anionic dextran 500 failed to buffer fluid drainage, but it reduced fluid escape and synovial conductance dQ̇s/dPj more than neutral dextran 500 (P < 0.0001, ANOVA). The anionic charge increased the molecular volume and viscosity of dextran 500. The results support the hypothesis that polymer molecular volume influences its reflection by interstitial matrix and outflow buffering. Polymer charge influences flow through an effect on viscosity and possibly electrostatic interactions with negatively charged interstitial matrix. PMID:11060134

  6. The Academic Neutrality Argument: Philosophical Discourse and La Regle du Jeu.

    ERIC Educational Resources Information Center

    Palermo, James

    1981-01-01

    Presents case studies representing various points of view on the question of whether academic institutions can remain neutral. Excerpts are presented from the writings of Kenneth Strike, Robert H. Ennis, John Dewey, and Louis Althusser. (DB)

  7. Characterization of a New Heat Dissipation Matric Potential Sensor

    PubMed Central

    Matile, Luzius; Berger, Roman; Wächter, Daniel; Krebs, Rolf

    2013-01-01

    Soil moisture sensors can help to reduce the amount of water needed for irrigation. In this paper we describe the PlantCare soil moisture sensor as a new type of heat dissipation sensor, its calibration and the correction for temperature changes. With the PlantCare sensor it is possible to measure the matric potential indirectly to monitor or control irrigation. This sensor is based on thermal properties of a synthetic felt. After a defined heating phase the cooling time to a threshold temperature is a function of the water content in the synthetic felt. The water content in this porous matrix is controlled by the matric potential in the surrounding soil. Calibration measurements have shown that the sensor is most sensitive to −400 hPa and allows lower sensitivity measurements to −800 hPa. The disturbing effect of the temperature change during the measurement on the cooling time can be corrected by a linear function and the differences among sensors are minimized by a two point calibration. PMID:23344384

  8. Reverse matrix converter control method for PMSM drives using DPC

    NASA Astrophysics Data System (ADS)

    Bak, Yeongsu; Lee, Kyo-Beum

    2018-05-01

    This paper proposes a control method for a reverse matrix converter (RMC) that drives a three-phase permanent magnet synchronous motor (PMSM). In this proposed method, direct power control (DPC) is used to control the voltage source rectifier of the RMC. The RMC is an indirect matrix converter operating in the boost mode, in which the power-flow directions of the input and output are switched. It has a minimum voltage transfer ratio of 1/0.866 in a linear-modulation region. In this paper, a control method that uses DPC as an additional control method is proposed in order to control the RMC driving a PMSM in the output stage. Simulations and experimental results verify the effectiveness of the proposed control method.

  9. Efficacy of tranexamic acid plus drain-clamping to reduce blood loss in total knee arthroplasty: A meta-analysis.

    PubMed

    Zhang, Yan; Zhang, Jun-Wei; Wang, Bao-Hua

    2017-06-01

    Perioperative blood loss is still an unsolved problem in total knee arthroplasty (TKA). The efficacy of the preoperative use of tranexamic acid (TXA) plus drain-clamping to reduce blood loss in TKA has been debated. This meta-analysis aimed to illustrate the efficacy of TXA plus drain-clamping to reduce blood loss in patients who underwent a TKA. In February 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, the Cochrane Database of Systematic Reviews, and Google Scholar. Data from patients prepared for TKA in studies that compared TXA plus drain-clamping versus TXA alone, drain-clamping alone, or controls were retrieved. The primary endpoint was the need for transfusion. The secondary outcomes were total blood loss, blood loss in drainage, the decrease in hemoglobin, and the occurrence of deep venous thrombosis. After testing for publication bias and heterogeneity between studies, data were aggregated for random-effects models when necessary. Ultimately, 5 clinical studies with 618 patients (TXA plus drain-clamping group = 249, control group = 130, TXA-alone group = 60, and drain-clamping group = 179) were included. TXA plus drain-clamping could decrease the need for transfusion, total blood loss, blood loss in drainage, and the decrease in hemoglobin than could the control group, the TXA-alone group, and the drain-clamping group (P < .05). There was no significant difference between the occurrence of deep venous thrombosis between the included groups (P > .05). TXA plus drain-clamping can achieve the maximum effects of hemostasis in patients prepared for primary TKA. Because the number and the quality of the included studies were limited, more high-quality randomized controlled trials are needed to identify the optimal dose of TXA and the clamping hours in patients prepared for TKA.

  10. Efficacy of tranexamic acid plus drain-clamping to reduce blood loss in total knee arthroplasty

    PubMed Central

    Zhang, Yan; Zhang, Jun-Wei; Wang, Bao-Hua

    2017-01-01

    Abstract Background: Perioperative blood loss is still an unsolved problem in total knee arthroplasty (TKA). The efficacy of the preoperative use of tranexamic acid (TXA) plus drain-clamping to reduce blood loss in TKA has been debated. This meta-analysis aimed to illustrate the efficacy of TXA plus drain-clamping to reduce blood loss in patients who underwent a TKA. Methods: In February 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, the Cochrane Database of Systematic Reviews, and Google Scholar. Data from patients prepared for TKA in studies that compared TXA plus drain-clamping versus TXA alone, drain-clamping alone, or controls were retrieved. The primary endpoint was the need for transfusion. The secondary outcomes were total blood loss, blood loss in drainage, the decrease in hemoglobin, and the occurrence of deep venous thrombosis. After testing for publication bias and heterogeneity between studies, data were aggregated for random-effects models when necessary. Results: Ultimately, 5 clinical studies with 618 patients (TXA plus drain-clamping group = 249, control group = 130, TXA-alone group = 60, and drain-clamping group = 179) were included. TXA plus drain-clamping could decrease the need for transfusion, total blood loss, blood loss in drainage, and the decrease in hemoglobin than could the control group, the TXA-alone group, and the drain-clamping group (P < .05). There was no significant difference between the occurrence of deep venous thrombosis between the included groups (P > .05). Conclusions: TXA plus drain-clamping can achieve the maximum effects of hemostasis in patients prepared for primary TKA. Because the number and the quality of the included studies were limited, more high-quality randomized controlled trials are needed to identify the optimal dose of TXA and the clamping hours in patients prepared for TKA. PMID:28658157

  11. The neutralizing role of IgM during early Chikungunya virus infection

    PubMed Central

    Chua, Chong-Long; Chiam, Chun-Wei; Chan, Yoke-Fun

    2017-01-01

    The antibody isotype IgM appears earlier than IgG, within days of onset of symptoms, and is important during the early stages of the adaptive immune response. Little is known about the functional role of IgM during infection with chikungunya virus (CHIKV), a recently reemerging arbovirus that has caused large global outbreaks. In this study, we studied antibody responses in 102 serum samples collected during CHIKV outbreaks in Malaysia. We described the neutralizing role of IgM at different times post-infection and examined the independent contributions of IgM and IgG towards the neutralizing capacity of human immune sera during the early phase of infection, including the differences in targets of neutralizing epitopes. Neutralizing IgM starts to appear as early as day 4 of symptoms, and their appearance from day 6 is associated with a reduction in viremia. IgM acts in a complementary manner with the early IgG, but plays the main neutralizing role up to a point between days 4 and 10 which varies between individuals. After this point, total neutralizing capacity is attributable almost entirely to the robust neutralizing IgG response. IgM preferentially binds and targets epitopes on the CHIKV surface E1-E2 glycoproteins, rather than individual E1 or E2. These findings provide insight into the early antibody responses to CHIKV, and have implications for design of diagnostic serological assays. PMID:28182795

  12. Effective Majorana mass matrix from tau and pseudoscalar meson lepton number violating decays

    NASA Astrophysics Data System (ADS)

    Abada, Asmaa; De Romeri, Valentina; Lucente, Michele; Teixeira, Ana M.; Toma, Takashi

    2018-02-01

    An observation of any lepton number violating process will undoubtedly point towards the existence of new physics and indirectly to the clear Majorana nature of the exchanged fermion. In this work, we explore the potential of a minimal extension of the Standard Model via heavy sterile fermions with masses in the [0.1 - 10] GeV range concerning an extensive array of "neutrinoless" meson and tau decay processes. We assume that the Majorana neutrinos are produced on-shell, and focus on three-body decays. We conduct an update on the bounds on the active-sterile mixing elements, |{U}_{ℓ }{{}{_{α}}}_4{U}_{ℓ }{{}{_{β}}}_4| , taking into account the most recent experimental bounds (and constraints) and new theoretical inputs, as well as the effects of a finite detector, imposing that the heavy neutrino decay within the detector. This allows to establish up-to-date comprehensive constraints on the sterile fermion parameter space. Our results suggest that the branching fractions of several decays are close to current sensitivities (likely within reach of future facilities), some being already in conflict with current data (as is the case of K + → ℓ α + ℓ β + π -, and τ - → μ +π-π-). We use these processes to extract constraints on all entries of an enlarged definition of a 3 × 3 "effective" Majorana neutrino mass matrix m ν αβ .

  13. Active experiments in modifying spacecraft potential: Results from ATS-5 and ATS-6

    NASA Technical Reports Server (NTRS)

    Olsen, R. C.; Whipple, E. C.

    1979-01-01

    The processing of data from onboard spacecraft instruments are described. The modification of spacecraft potentials is reviewed. Analysis of this data yielded the following results: (1) electron emission (E approximately 10 electron-volts) did not perturb the status of a satellite at low potential the absolute value of phi approximately 50 volts by more than 50 volts (the ATS 5 low energy limit), (2) emission of a low energy plasma (E approximatey 10 volts) does not change low potentials (the absolute value of phi approximately 5 volts) by more than a few volts (ATS 6 low energy resolution), (3) when ATS 6 entered eclipse in the presence of a high energy plasma (10 keV), the neutralizer suppressed any rise in the absolute value of phi (within a few volts resolution), (4) when the electron emitter on ATS 5 operated, it served to discharge negative potentials from thousands to hundreds of volts, and (5) when the neutralizer on ATS 6 was operated, it served to discharge kilovolt potentials to below 50 volts. Low altitude (100 - 300 km) experiments with KV electron beams are studied. Differential charging was eliminated by the operation of the main thruster on ATS 6 clamped on the spacecraft at -5 volts.

  14. Studies of the pedestal structure and inter-ELM pedestal evolution in JET with the ITER-like wall

    NASA Astrophysics Data System (ADS)

    Maggi, C. F.; Frassinetti, L.; Horvath, L.; Lunniss, A.; Saarelma, S.; Wilson, H.; Flanagan, J.; Leyland, M.; Lupelli, I.; Pamela, S.; Urano, H.; Garzotti, L.; Lerche, E.; Nunes, I.; Rimini, F.; Contributors, JET

    2017-11-01

    The pedestal structure of type I ELMy H-modes has been analysed for JET with the ITER-like Wall (JET-ILW). The electron pressure pedestal width is independent of ρ * and increases proportionally to  √β pol,PED. Additional broadening of the width is observed, at constant β pol, PED, with increasing ν * and/or neutral gas injection and the contribution of atomic physics effects in setting the pedestal width cannot as yet be ruled out. Neutral penetration alone does not determine the shape of the edge density profile in JET-ILW. The ratio of electron density to electron temperature scale lengths in the edge transport barrier region, η e, is of order 2-3 within experimental uncertainties. Existing understanding, represented in the stationary linear peeling-ballooning mode stability and the EPED pedestal structure models, is extended to the dynamic evolution between ELM crashes in JET-ILW, in order to test the assumptions underlying these two models. The inter-ELM temporal evolution of the pedestal structure in JET-ILW is not unique, but depends on discharge conditions, such as heating power and gas injection levels. The strong reduction in p e,PED with increasing D 2 gas injection at high power is primarily due to clamping of \

  15. High quality cord blood banking is feasible with delayed clamping practices. The eight-year experience and current status of the national Swedish Cord Blood Bank.

    PubMed

    Frändberg, Sofia; Waldner, Berit; Konar, Jan; Rydberg, Lennart; Fasth, Anders; Holgersson, Jan

    2016-09-01

    The National Swedish Cord Blood Bank (NS-CBB) is altruistic and publicly funded. Herein we describe the status of the bank and the impact of delayed versus early clamping on cell number and volume. Cord Blood Units (CBUs) were collected at two University Hospitals in Sweden. Collected volume and nucleated cell content (TNC) were investigated in 146 consecutive Cord Blood (CB) collections sampled during the first quarter of 2012 and in 162 consecutive CB collections done in the first quarter of 2013, before and after clamping practices were changed from immediate to late (60 s) clamping. NS-CBB now holds close to 5000 units whereof 30 % are from non-Caucasian or mixed origins. Delayed clamping had no major effect on collection efficiency. The volume collected was slightly reduced (mean difference, 8.1 ml; 95 % CI, 1.3-15.0 ml; p = 0.02), while cell recovery was not (p = 0.1). The proportion of CBUs that met initial total TNC banking criteria was 60 % using a TNC threshold of 12.5 × 10(8), and 47 % using a threshold of 15 × 10(8) for the early clamping group and 52 and 37 % in the late clamping group. Following implementation of delayed clamping practices at NS-CBB; close to 40 % of the collections in the late clamping group still met the high TNC banking threshold and were eligible for banking, implicating that that cord blood banking is feasible with delayed clamping practices.

  16. Synchronisation control for neutral-type multi-slave stochastic hybrid systems

    NASA Astrophysics Data System (ADS)

    Zhou, Jun; Pan, Feng; Cai, Tingting; Sun, Yuqing; Zhou, Wuneng; Liu, Huashan

    2017-10-01

    In this paper, an exponential synchronisation problem for neutral-type multi-slave hybrid systems with stochastic perturbation is discussed, where the adaptive synchronisation model involves a master system and multiple slave systems. By the use of generalised It?'s formula and M-matrix method, a sufficient condition is obtained to guarantee the stability of the error system, and the update law of the feedback controller is determined to deduce the synchronisation between the master system and the sum system of all slave systems. Finally, a numerical example is given to illustrate the effectiveness of the results obtained in this paper.

  17. Quantifying Insulin Sensitivity and Entero-Insular Responsiveness to Hyper- and Hypoglycemia in Ferrets

    PubMed Central

    Sui, Hongshu; Yi, Yaling; Yao, Jianrong; Liang, Bo; Sun, Xingshen; Hu, Shanming; Uc, Aliye; Nelson, Deborah J.; Ode, Katie Larson; Philipson, Louis H.; Engelhardt, John F.; Norris, Andrew W.

    2014-01-01

    Ferrets are an important emerging model of cystic fibrosis related diabetes. However, there is little documented experience in the use of advanced techniques to quantify aspects of diabetes pathophysiology in the ferret. Glycemic clamps are the gold standard technique to assess both insulin sensitivity and insulin secretion in humans and animal models of diabetes. We therefore sought to develop techniques for glycemic clamps in ferrets. To assess insulin sensitivity, we performed euglycemic hyperinsulinemic clamps in 5–6 week old ferrets in the anesthetized and conscious states. To assess insulin secretion, we performed hyperglycemic clamps in conscious ferrets. To evaluate responsiveness of ferret islet and entero-insular hormones to low glucose, a portion of the hyperglycemic clamps were followed by a hypoglycemic clamp. The euglycemic hyperinsulinemic clamps demonstrated insulin responsiveness in ferrets similar to that previously observed in humans and rats. The anesthetic isoflurane induced marked insulin resistance, whereas lipid emulsion induced mild insulin resistance. In conscious ferrets, glucose appearance was largely suppressed at 4 mU/kg/min insulin infusion, whereas glucose disposal was progressively increased at 4 and 20 mU/kg/min insulin. Hyperglycemic clamp induced first phase insulin secretion. Hypoglycemia induced a rapid diminishment of insulin, as well as a rise in glucagon and pancreatic polypeptide levels. The incretins GLP-1 and GIP were affected minimally by hyperglycemic and hypoglycemic clamp. These techniques will prove useful in better defining the pathophysiology in ferrets with cystic fibrosis related diabetes. PMID:24594704

  18. A Comparison of the Performance and Application Differences Between Manual and Automated Patch-Clamp Techniques

    PubMed Central

    Yajuan, Xiao; Xin, Liang; Zhiyuan, Li

    2012-01-01

    The patch clamp technique is commonly used in electrophysiological experiments and offers direct insight into ion channel properties through the characterization of ion channel activity. This technique can be used to elucidate the interaction between a drug and a specific ion channel at different conformational states to understand the ion channel modulators’ mechanisms. The patch clamp technique is regarded as a gold standard for ion channel research; however, it suffers from low throughput and high personnel costs. In the last decade, the development of several automated electrophysiology platforms has greatly increased the screen throughput of whole cell electrophysiological recordings. New advancements in the automated patch clamp systems have aimed to provide high data quality, high content, and high throughput. However, due to the limitations noted above, automated patch clamp systems are not capable of replacing manual patch clamp systems in ion channel research. While automated patch clamp systems are useful for screening large amounts of compounds in cell lines that stably express high levels of ion channels, the manual patch clamp technique is still necessary for studying ion channel properties in some research areas and for specific cell types, including primary cells that have mixed cell types and differentiated cells that derive from induced pluripotent stem cells (iPSCs) or embryonic stem cells (ESCs). Therefore, further improvements in flexibility with regard to cell types and data quality will broaden the applications of the automated patch clamp systems in both academia and industry. PMID:23346269

  19. MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C

    PubMed Central

    Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.

    2012-01-01

    We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681

  20. Quantifying insulin sensitivity and entero-insular responsiveness to hyper- and hypoglycemia in ferrets.

    PubMed

    Sui, Hongshu; Yi, Yaling; Yao, Jianrong; Liang, Bo; Sun, Xingshen; Hu, Shanming; Uc, Aliye; Nelson, Deborah J; Ode, Katie Larson; Philipson, Louis H; Engelhardt, John F; Norris, Andrew W

    2014-01-01

    Ferrets are an important emerging model of cystic fibrosis related diabetes. However, there is little documented experience in the use of advanced techniques to quantify aspects of diabetes pathophysiology in the ferret. Glycemic clamps are the gold standard technique to assess both insulin sensitivity and insulin secretion in humans and animal models of diabetes. We therefore sought to develop techniques for glycemic clamps in ferrets. To assess insulin sensitivity, we performed euglycemic hyperinsulinemic clamps in 5-6 week old ferrets in the anesthetized and conscious states. To assess insulin secretion, we performed hyperglycemic clamps in conscious ferrets. To evaluate responsiveness of ferret islet and entero-insular hormones to low glucose, a portion of the hyperglycemic clamps were followed by a hypoglycemic clamp. The euglycemic hyperinsulinemic clamps demonstrated insulin responsiveness in ferrets similar to that previously observed in humans and rats. The anesthetic isoflurane induced marked insulin resistance, whereas lipid emulsion induced mild insulin resistance. In conscious ferrets, glucose appearance was largely suppressed at 4 mU/kg/min insulin infusion, whereas glucose disposal was progressively increased at 4 and 20 mU/kg/min insulin. Hyperglycemic clamp induced first phase insulin secretion. Hypoglycemia induced a rapid diminishment of insulin, as well as a rise in glucagon and pancreatic polypeptide levels. The incretins GLP-1 and GIP were affected minimally by hyperglycemic and hypoglycemic clamp. These techniques will prove useful in better defining the pathophysiology in ferrets with cystic fibrosis related diabetes.

  1. Group identity and positive deviance in work groups.

    PubMed

    Kim, Moon Joung; Choi, Jin Nam

    2017-12-05

    This study examines why and how identity cognitions, including group identification and individual differentiation, influence the positive deviance of employees. We identify the risk-taking intention of employees as a critical psychological mechanism to overcome stigma-induced identity threat of positive deviance. The analysis of data collected from 293 members comprising 66 work teams reveals that the relationship between individual differentiation and positive deviance is partially mediated by risk-taking intention. The indirect effect of group identification on positive deviance through risk-taking intention is also significant and positive in groups with low conformity pressure, whereas the same indirect effect is neutralized in groups with high conformity pressure. The current analysis offers new insights into the way the group context and the identity cognition of members explain the development of positive deviance and workplace creativity.

  2. Neutral point testing of color vision in the domestic cat.

    PubMed

    Clark, Daria L; Clark, Robert A

    2016-12-01

    Despite extensive study, the basic nature of feline spectral sensitivity is still unresolved. Most electrophysiological studies have demonstrated two photopic receptors within the cat's retina, one most sensitive to longer wavelengths near 560 nm and the other most sensitive to shorter wavelengths near 460 nm, providing the neuroretinal basis for dichromatic vision. A few studies, however, have detected a third photopic receptor most sensitive to medium wavelengths between 500 and 520 nm, overlapping in spectrally sensitivity with the feline scotopic receptor, that potentially could allow trichromatic vision. Indeed, one behavioral study has demonstrated trichromatic vision in cats, but a flaw within its experimental design raises the possibility that achromatic intensity cues might have allowed the accurate identification of medium wavelength targets. This study tested for a spectral neutral point in the domestic cat using a two-choice discrimination task. The positive targets were created using monochromatic light from various single wavelength light emitting diodes (LEDs) combined with a white light of variable intensity, while the negative targets were created using white light of variable intensity. Trials were performed with varying intensities of positive and negative targets, from brighter positive targets to brighter negative targets, to eliminate achromatic intensity cues. Two cats with prior experience with two-choice discrimination tasks, one male and one female, successfully discriminated monochromatic light from 456 nm to 497 nm and from 510 nm to 524 nm, but both failed to discriminate monochromatic light at 505 nm over multiple trials. These results provide strong evidence that cats are dichromatic with a neutral point near 505 nm. This neutral point is nearly identical to the neutral point of the human deuteuranope, making feline vision a more accurate a model for red-green colorblind individuals than normal trichromats. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Dynamic assembly of Hda and the sliding clamp in the regulation of replication licensing.

    PubMed

    Kim, Jin S; Nanfara, Michael T; Chodavarapu, Sundari; Jin, Kyeong S; Babu, Vignesh M P; Ghazy, Mohamed A; Chung, Scisung; Kaguni, Jon M; Sutton, Mark D; Cho, Yunje

    2017-04-20

    Regulatory inactivation of DnaA (RIDA) is one of the major regulatory mechanisms of prokaryotic replication licensing. In RIDA, the Hda-sliding clamp complex loaded onto DNA directly interacts with adenosine triphosphate (ATP)-bound DnaA and stimulates the hydrolysis of ATP to inactivate DnaA. A prediction is that the activity of Hda is tightly controlled to ensure that replication initiation occurs only once per cell cycle. Here, we determined the crystal structure of the Hda-β clamp complex. This complex contains two pairs of Hda dimers sandwiched between two β clamp rings to form an octamer that is stabilized by three discrete interfaces. Two separate surfaces of Hda make contact with the β clamp, which is essential for Hda function in RIDA. The third interface between Hda monomers occludes the active site arginine finger, blocking its access to DnaA. Taken together, our structural and mutational analyses of the Hda-β clamp complex indicate that the interaction of the β clamp with Hda controls the ability of Hda to interact with DnaA. In the octameric Hda-β clamp complex, the inability of Hda to interact with DnaA is a novel mechanism that may regulate Hda function. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  4. Dynamic assembly of Hda and the sliding clamp in the regulation of replication licensing

    PubMed Central

    Kim, Jin S.; Nanfara, Michael T.; Chodavarapu, Sundari; Jin, Kyeong S.; Babu, Vignesh M. P.; Ghazy, Mohamed A.; Chung, Scisung

    2017-01-01

    Abstract Regulatory inactivation of DnaA (RIDA) is one of the major regulatory mechanisms of prokaryotic replication licensing. In RIDA, the Hda–sliding clamp complex loaded onto DNA directly interacts with adenosine triphosphate (ATP)-bound DnaA and stimulates the hydrolysis of ATP to inactivate DnaA. A prediction is that the activity of Hda is tightly controlled to ensure that replication initiation occurs only once per cell cycle. Here, we determined the crystal structure of the Hda–β clamp complex. This complex contains two pairs of Hda dimers sandwiched between two β clamp rings to form an octamer that is stabilized by three discrete interfaces. Two separate surfaces of Hda make contact with the β clamp, which is essential for Hda function in RIDA. The third interface between Hda monomers occludes the active site arginine finger, blocking its access to DnaA. Taken together, our structural and mutational analyses of the Hda–β clamp complex indicate that the interaction of the β clamp with Hda controls the ability of Hda to interact with DnaA. In the octameric Hda–β clamp complex, the inability of Hda to interact with DnaA is a novel mechanism that may regulate Hda function. PMID:28168278

  5. Lower dipeptidyl peptidase-4 following exercise training plus weight loss is related to increased insulin sensitivity in adults with metabolic syndrome.

    PubMed

    Malin, Steven K; Huang, Hazel; Mulya, Anny; Kashyap, Sangeeta R; Kirwan, John P

    2013-09-01

    Dipeptidyl peptidase-4 (DPP-4) is a circulating glycoprotein that impairs insulin-stimulated glucose uptake and is linked to obesity and metabolic syndrome. However, the effect of exercise on plasma DPP-4 in adults with metabolic syndrome is unknown. Therefore, we determined the effect of exercise on DPP-4 and its role in explaining exercise-induced improvements in insulin sensitivity. Fourteen obese adults (67.9±1.2 years, BMI: 34.2±1.1kg/m(2)) with metabolic syndrome (ATP III criteria) underwent a 12-week supervised exercise intervention (60min/day for 5 days/week at ∼85% HRmax). Plasma DPP-4 was analyzed using an enzyme-linked immunosorbent assay. Insulin sensitivity was measured using the euglycemic-hyperinsulinemic clamp (40mU/m(2)/min) and estimated by HOMA-IR. Visceral fat (computerized tomography), 2-h glucose levels (75g oral glucose tolerance), and basal fat oxidation as well as aerobic fitness (indirect calorimetry) were also determined before and after exercise. The intervention reduced visceral fat, lowered blood pressure, glucose and lipids, and increased aerobic fitness (P<0.05). Exercise improved clamp-derived insulin sensitivity by 75% (P<0.001) and decreased HOMA-IR by 15% (P<0.05). Training decreased plasma DPP-4 by 10% (421.8±30.1 vs. 378.3±32.5ng/ml; P<0.04), and the decrease in DPP-4 was associated with clamp-derived insulin sensitivity (r=-0.59; P<0.04), HOMA-IR (r=0.59; P<0.04) and fat oxidation (r=-0.54; P<0.05). Increased fat oxidation also correlated with lower 2-h glucose levels (r=-0.64; P<0.02). Exercise training reduces plasma DPP-4, which may be linked to elevated insulin sensitivity and fat oxidation. Maintaining low plasma DPP-4 concentrations is a potential mechanism whereby exercise plus weight loss prevents/delays the onset of type 2 diabetes in adults with metabolic syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Cromwell, B. K.; Shepherd, S. D.; Pender, C. W.; Wood, B. E.

    1993-01-01

    Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.

  7. Advanced motor driven clamped borehole seismic receiver

    DOEpatents

    Engler, B.P.; Sleefe, G.E.; Striker, R.P.

    1993-02-23

    A borehole seismic tool is described including a borehole clamp which only moves perpendicular to the borehole. The clamp is driven by an electric motor, via a right angle drive. When used as a seismic receiver, the tool has a three part housing, two of which are hermetically sealed. Accelerometers or geophones are mounted in one hermetically sealed part, the electric motor in the other hermetically sealed part, and the clamp and right angle drive in the third part. Preferably the tool includes cable connectors at both ends. Optionally a shear plate can be added to the clamp to extend the range of the tool.

  8. Multiple-mode nonlinear free and forced vibrations of beams using finite element method

    NASA Technical Reports Server (NTRS)

    Mei, Chuh; Decha-Umphai, Kamolphan

    1987-01-01

    Multiple-mode nonlinear free and forced vibration of a beam is analyzed by the finite element method. The geometric nonlinearity is investigated. Inplane displacement and inertia (IDI) are also considered in the formulation. Harmonic force matrix is derived and explained. Nonlinear free vibration can be simply treated as a special case of the general forced vibration by setting the harmonic force matrix equal to zero. The effect of the higher modes is more pronouced for the clamped supported beam than the simply supported one. Beams without IDI yield more effect of the higher modes than the one with IDI. The effects of IDI are to reduce nonlinearity. For beams with end supports restrained from axial movement (immovable cases), only the hardening type nonlinearity is observed. However, beams of small slenderness ratio (L/R = 20) with movable end supports, the softening type nonlinearity is found. The concentrated force case yields a more severe response than the uniformly distributed force case. Finite element results are in good agreement with the solution of simple elliptic response, harmonic balance method, and Runge-Kutte method and experiment.

  9. Sperm Patch-Clamp

    PubMed Central

    Lishko, Polina; Clapham, David E.; Navarro, Betsy; Kirichok, Yuriy

    2014-01-01

    Sperm intracellular pH and calcium concentration ([Ca2+]i) are two central factors that control sperm activity within the female reproductive tract. As such, the ion channels of the sperm plasma membrane that alter intracellular sperm [Ca2+] and pH play important roles in sperm physiology and the process of fertilization. Indeed, sperm ion channels regulate sperm motility, control sperm chemotaxis toward the egg in some species, and may trigger the acrosome reaction. Until recently, our understanding of these important molecules was rudimentary due to the inability to patch-clamp spermatozoa and directly record the activity of these ion channels under voltage clamp. Recently, we overcame this technical barrier and developed a method for reproducible application of the patch-clamp technique to mouse and human spermatozoa. This chapter covers important aspects of application of the patch-clamp technique to spermatozoa, such as selection of the electrophysiological equipment, isolation of spermatozoa for patch-clamp experiments, formation of the gigaohm seal with spermatozoa, and transition into the whole-cell mode of recording. We also discuss potential pitfalls in application of the patch-clamp technique to flagellar ion channels. PMID:23522465

  10. Quantum Hall signatures of dipolar Mahan excitons

    NASA Astrophysics Data System (ADS)

    Schinner, G. J.; Repp, J.; Kowalik-Seidl, K.; Schubert, E.; Stallhofer, M. P.; Rai, A. K.; Reuter, D.; Wieck, A. D.; Govorov, A. O.; Holleitner, A. W.; Kotthaus, J. P.

    2013-01-01

    We explore the photoluminescence of spatially indirect, dipolar Mahan excitons in a gated double quantum well diode containing a mesoscopic electrostatic trap for neutral dipolar excitons at low temperatures down to 250 mK and in quantizing magnetic fields. Mahan excitons in the surrounding of the trap, consisting of individual holes interacting with a degenerate two-dimensional electron system confined in one of the quantum wells, exhibit strong quantum Hall signatures at integer filling factors and related anomalies around filling factor ν=(2)/(3),(3)/(5), and (1)/(2), reflecting the formation of composite fermions. Interactions across the trap perimeter are found to influence the energy of the confined neutral dipolar excitons by the presence of the quantum Hall effects in the two-dimensional electron system surrounding the trap.

  11. Improved Intermittent-clamped Drainage in Lower Lumbar Internal Fixation: A Randomized Prospective Study

    PubMed Central

    Hao, Qing-Ying; Liu, Chu-Yin; Fu, Chan-Juan; Zhang, Xiao-Hua; Tan, Ming-Sheng

    2016-01-01

    Background: Continuous negative pressure drainage (CNPD) is widely used after lower lumbar internal fixation; however, it may cause tremendous blood loss and lead to postoperative hemorrhagic anemia. The present study explored the efficacy and safety of improved intermittent-clamped drainage (ICD) for lower lumbar internal fixation. Methods: This was a prospective study that included 156 patients with decompression of the spinal canal and internal fixation for the first time from January 2012 to December 2014. The patients were randomly divided into ICD group and CNPD group, and each group had 78 cases. A drainage tube was placed under the deep fascia in all patients within 10 min after the commencement of wound closure. The postoperative drainage amount at different time points, the hemoglobin level, and postoperative complications were recorded and compared between the two groups. Shapiro-Wilk test, independent samples t-test, and Mann-Whitney U-test were used in this study. Results: The drainage amount was significantly reduced in the ICD group, as compared with the CNPD group (Z = 10.74, P < 0.01). The mean total drainage amount (in ml) of the single-segment and two-segment procedures was significantly greater in the CNPD group than the ICD group (Z = 10.63 and 10.75, respectively; P < 0.01). For the adverse events, there was no significant difference in postoperative temperature, wound problem, and complications between the two groups. Conclusions: The present study showed a statistically significant reduction in postoperative drainage amount between ICD and CNPD groups, and ICD is an effective, convenient, and safe method for routine use in lower lumbar surgery. It is essential to focus on the effect of clamping drainage with long-segment surgical procedure and complex lumbar disease in the further investigation, as well as the effect of clamping on long-term functional outcomes. PMID:27900992

  12. Opto-current-clamp actuation of cortical neurons using a strategically designed channelrhodopsin.

    PubMed

    Wen, Lei; Wang, Hongxia; Tanimoto, Saki; Egawa, Ryo; Matsuzaka, Yoshiya; Mushiake, Hajime; Ishizuka, Toru; Yawo, Hiromu

    2010-09-23

    Optogenetic manipulation of a neuronal network enables one to reveal how high-order functions emerge in the central nervous system. One of the Chlamydomonas rhodopsins, channelrhodopsin-1 (ChR1), has several advantages over channelrhodopsin-2 (ChR2) in terms of the photocurrent kinetics. Improved temporal resolution would be expected by the optogenetics using the ChR1 variants with enhanced photocurrents. The photocurrent retardation of ChR1 was overcome by exchanging the sixth helix domain with its counterpart in ChR2 producing Channelrhodopsin-green receiver (ChRGR) with further reform of the molecule. When the ChRGR photocurrent was measured from the expressing HEK293 cells under whole-cell patch clamp, it was preferentially activated by green light and has fast kinetics with minimal desensitization. With its kinetic advantages the use of ChRGR would enable one to inject a current into a neuron by the time course as predicted by the intensity of the shedding light (opto-current clamp). The ChRGR was also expressed in the motor cortical neurons of a mouse using Sindbis pseudovirion vectors. When an oscillatory LED light signal was applied sweeping through frequencies, it robustly evoked action potentials synchronized to the oscillatory light at 5-10 Hz in layer 5 pyramidal cells in the cortical slice. The ChRGR-expressing neurons were also driven in vivo with monitoring local field potentials (LFPs) and the time-frequency energy distribution of the light-evoked response was investigated using wavelet analysis. The oscillatory light enhanced both the in-phase and out-phase responses of LFP at the preferential frequencies of 5-10 Hz. The spread of activity was evidenced by the fact that there were many c-Fos-immunoreactive neurons that were negative for ChRGR in a region of the motor cortex. The opto-current-clamp study suggests that the depolarization of a small number of neurons wakes up the motor cortical network over some critical point to the activated state.

  13. Automated exploitation of sky polarization imagery.

    PubMed

    Sadjadi, Firooz A; Chun, Cornell S L

    2018-03-10

    We propose an automated method for detecting neutral points in the sunlit sky. Until now, detecting these singularities has been done manually. Results are presented that document the application of this method on a limited number of polarimetric images of the sky captured with a camera and rotating polarizer. The results are significant because a method for automatically detecting the neutral points may aid in the determination of the solar position when the sun is obscured and may have applications in meteorology and pollution detection and characterization.

  14. Rényi-Fisher entropy product as a marker of topological phase transitions

    NASA Astrophysics Data System (ADS)

    Bolívar, J. C.; Nagy, Ágnes; Romera, Elvira

    2018-05-01

    The combined Rényi-Fisher entropy product of electrons plus holes displays a minimum at the charge neutrality points. The Stam-Rényi difference and the Stam-Rényi uncertainty product of the electrons plus holes, show maxima at the charge neutrality points. Topological quantum numbers capable of detecting the topological insulator and the band insulator phases, are defined. Upper and lower bounds for the position and momentum space Rényi-Fisher entropy products are derived.

  15. Indirect Effects of Environmental Change in Resource Competition Models.

    PubMed

    Kleinhesselink, Andrew R; Adler, Peter B

    2015-12-01

    Anthropogenic environmental change can affect species directly by altering physiological rates or indirectly by changing competitive outcomes. The unknown strength of competition-mediated indirect effects makes it difficult to predict species abundances in the face of ongoing environmental change. Theory developed with phenomenological competition models shows that indirect effects are weak when coexistence is strongly stabilized, but these models lack a mechanistic link between environmental change and species performance. To extend existing theory, we examined the relationship between coexistence and indirect effects in mechanistic resource competition models. We defined environmental change as a change in resource supply points and quantified the resulting competition-mediated indirect effects on species abundances. We found that the magnitude of indirect effects increases in proportion to niche overlap. However, indirect effects also depend on differences in how competitors respond to the change in resource supply, an insight hidden in nonmechanistic models. Our analysis demonstrates the value of using niche overlap to predict the strength of indirect effects and clarifies the types of indirect effects that global change can have on competing species.

  16. Death and injury in aerial spraying: pre-crash, crash, and post-crash prevention strategies.

    PubMed

    Richter, E D; Gordon, M; Halamish, M; Gribetz, B

    1981-01-01

    To prevent crash-related death and injury among spray pilots, a program including pre-crash, crash and post-crash stages of intervention for aircraft, physical environment, and pilots and ground crews was proposed in accordance with a matrix of options derived from road crash epidemiology. In addition to the dangers of fixed obstacles, low-altitude runs, and heavy work schedules, work hazards included combined exposures to noise, vibration, G forces, heat stress, pesticides, and dehydration. Together, these exposures were believed to have produced slight, but crucial decreases in pilot performance, alertness and skill. For aircraft, the major pre-crash measure was cockpit air cooling, with filter technologies to prevent in-flight pesticide exposure. Crash and post-crash design changes to reduce energy transfers to the pilot's body (thermal, kinetic) were the most important recommendations, because absolute prevention of the crash event was unlikely. For the environment, pre-crash recommendations included marking fixed obstacles, such as power and telephone lines, but preferably their elimination. Other measures included drainage pits with sodium hydroxide points to neutralize parathion and prevent dispersion of parathion-containing mists. Pilot pre-crash measures (more fluid intake, biological monitoring--EMG, urinary alkyl phosphate, cholinesterase testing) required special organizational arrangements. Systematic application of options from the foregoing matrix suggest that the high risk of death and injury from aerial spraying is unnecessary.

  17. Differences between Doppler velocities of ions and neutral atoms in a solar prominence

    NASA Astrophysics Data System (ADS)

    Anan, T.; Ichimoto, K.; Hillier, A.

    2017-05-01

    Context. In astrophysical systems with partially ionized plasma, the motion of ions is governed by the magnetic field while the neutral particles can only feel the magnetic field's Lorentz force indirectly through collisions with ions. The drift in the velocity between ionized and neutral species plays a key role in modifying important physical processes such as magnetic reconnection, damping of magnetohydrodynamic waves, transport of angular momentum in plasma through the magnetic field, and heating. Aims: This paper aims to investigate the differences between Doppler velocities of calcium ions and neutral hydrogen in a solar prominence to look for velocity differences between the neutral and ionized species. Methods: We simultaneously observed spectra of a prominence over an active region in H I 397 nm, H I 434 nm, Ca II 397 nm, and Ca II 854 nm using a high dispersion spectrograph of the Domeless Solar Telescope at Hida observatory. We compared the Doppler velocities, derived from the shift of the peak of the spectral lines presumably emitted from optically-thin plasma. Results: There are instances when the difference in velocities between neutral atoms and ions is significant, for example 1433 events ( 3% of sets of compared profiles) with a difference in velocity between neutral hydrogen atoms and calcium ions greater than 3σ of the measurement error. However, we also found significant differences between the Doppler velocities of two spectral lines emitted from the same species, and the probability density functions of velocity difference between the same species is not significantly different from those between neutral atoms and ions. Conclusions: We interpreted the difference of Doppler velocities as being a result of the motions of different components in the prominence along the line of sight, rather than the decoupling of neutral atoms from plasma. The movie attached to Fig. 1 is available at http://www.aanda.org

  18. Computational study of textured ferroelectric polycrystals: Dielectric and piezoelectric properties of template-matrix composites

    NASA Astrophysics Data System (ADS)

    Zhou, Jie E.; Yan, Yongke; Priya, Shashank; Wang, Yu U.

    2017-01-01

    Quantitative relationships between processing, microstructure, and properties in textured ferroelectric polycrystals and the underlying responsible mechanisms are investigated by phase field modeling and computer simulation. This study focuses on three important aspects of textured ferroelectric ceramics: (i) grain microstructure evolution during templated grain growth processing, (ii) crystallographic texture development as a function of volume fraction and seed size of the templates, and (iii) dielectric and piezoelectric properties of the obtained template-matrix composites of textured polycrystals. Findings on the third aspect are presented here, while an accompanying paper of this work reports findings on the first two aspects. In this paper, the competing effects of crystallographic texture and template seed volume fraction on the dielectric and piezoelectric properties of ferroelectric polycrystals are investigated. The phase field model of ferroelectric composites consisting of template seeds embedded in matrix grains is developed to simulate domain evolution, polarization-electric field (P-E), and strain-electric field (ɛ-E) hysteresis loops. The coercive field, remnant polarization, dielectric permittivity, piezoelectric coefficient, and dissipation factor are studied as a function of grain texture and template seed volume fraction. It is found that, while crystallographic texture significantly improves the polycrystal properties towards those of single crystals, a higher volume fraction of template seeds tends to decrease the electromechanical properties, thus canceling the advantage of ferroelectric polycrystals textured by templated grain growth processing. This competing detrimental effect is shown to arise from the composite effect, where the template phase possesses material properties inferior to the matrix phase, causing mechanical clamping and charge accumulation at inter-phase interfaces between matrix and template inclusions. The computational results are compared with complementary experiments, where good agreement is obtained.

  19. Synchronization of action potentials during low-magnesium-induced bursting

    PubMed Central

    Johnson, Sarah E.; Hudson, John L.

    2015-01-01

    The relationship between mono- and polysynaptic strength and action potential synchronization was explored using a reduced external Mg2+ model. Single and dual whole cell patch-clamp recordings were performed in hippocampal cultures in three concentrations of external Mg2+. In decreased Mg2+ medium, the individual cells transitioned to spontaneous bursting behavior. In lowered Mg2+ media the larger excitatory synaptic events were observed more frequently and fewer transmission failures occurred, suggesting strengthened synaptic transmission. The event synchronization was calculated for the neural action potentials of the cell pairs, and it increased in media where Mg2+ concentration was lowered. Analysis of surrogate data where bursting was present, but no direct or indirect connections existed between the neurons, showed minimal action potential synchronization. This suggests the synchronization of action potentials is a product of the strengthening synaptic connections within neuronal networks. PMID:25609103

  20. Synchronization of action potentials during low-magnesium-induced bursting.

    PubMed

    Johnson, Sarah E; Hudson, John L; Kapur, Jaideep

    2015-04-01

    The relationship between mono- and polysynaptic strength and action potential synchronization was explored using a reduced external Mg(2+) model. Single and dual whole cell patch-clamp recordings were performed in hippocampal cultures in three concentrations of external Mg(2+). In decreased Mg(2+) medium, the individual cells transitioned to spontaneous bursting behavior. In lowered Mg(2+) media the larger excitatory synaptic events were observed more frequently and fewer transmission failures occurred, suggesting strengthened synaptic transmission. The event synchronization was calculated for the neural action potentials of the cell pairs, and it increased in media where Mg(2+) concentration was lowered. Analysis of surrogate data where bursting was present, but no direct or indirect connections existed between the neurons, showed minimal action potential synchronization. This suggests the synchronization of action potentials is a product of the strengthening synaptic connections within neuronal networks. Copyright © 2015 the American Physiological Society.

  1. Cholinergic, serotoninergic and peptidergic components of the nervous system of Discocotyle sagittata (Monogenea:Polyopisthocotylea).

    PubMed

    Cable, J; Marks, N J; Halton, D W; Shaw, C; Johnston, C F; Tinsley, R C; Gannicott, A M

    1996-12-01

    Cholinergic, serotoninergic (5-HT) and peptidergic neuronal pathways have been demonstrated in both central and peripheral nervous systems of adult Discocotyle sagittata, using enzyme histochemistry and indirect immunocytochemistry in conjunction with confocal scanning laser microscopy. Antisera to 2 native flatworm neuropeptides, neuropeptide F and the FMRFamide-related peptide (FaRP), GNFFRFamide, were employed to detect peptide immunoreactivity. The CNS is composed of paired cerebral ganglia and connecting dorsal commissure, together with several paired longitudinal nerve cords. The main longitudinal nerve cords (lateral, ventral and dorsal) are interconnected at intervals by a series of annular cross-connectives, producing a ladder-like arrangement typical of the platyhelminth nervous system. At the level of the haptor, the ventral cords provide nerve roots which innervate each of the 9 clamps. Cholinergic and peptidergic neuronal organisation was similar, but distinct from that of the serotoninergic components. The PNS and reproductive system are predominantly innervated by peptidergic neurones.

  2. Collagen matrix as a tool in studying fibroblastic cell behavior.

    PubMed

    Kanta, Jiří

    2015-01-01

    Type I collagen is a fibrillar protein, a member of a large family of collagen proteins. It is present in most body tissues, usually in combination with other collagens and other components of extracellular matrix. Its synthesis is increased in various pathological situations, in healing wounds, in fibrotic tissues and in many tumors. After extraction from collagen-rich tissues it is widely used in studies of cell behavior, especially those of fibroblasts and myofibroblasts. Cells cultured in a classical way, on planar plastic dishes, lack the third dimension that is characteristic of body tissues. Collagen I forms gel at neutral pH and may become a basis of a 3D matrix that better mimics conditions in tissue than plastic dishes.

  3. Collagen matrix as a tool in studying fibroblastic cell behavior

    PubMed Central

    Kanta, Jiří

    2015-01-01

    Type I collagen is a fibrillar protein, a member of a large family of collagen proteins. It is present in most body tissues, usually in combination with other collagens and other components of extracellular matrix. Its synthesis is increased in various pathological situations, in healing wounds, in fibrotic tissues and in many tumors. After extraction from collagen-rich tissues it is widely used in studies of cell behavior, especially those of fibroblasts and myofibroblasts. Cells cultured in a classical way, on planar plastic dishes, lack the third dimension that is characteristic of body tissues. Collagen I forms gel at neutral pH and may become a basis of a 3D matrix that better mimics conditions in tissue than plastic dishes. PMID:25734486

  4. Photochemical and radiation-chemical aspects of matrix acidity effects on some organic systems

    NASA Astrophysics Data System (ADS)

    Ambroz, H. B.; Przybytniak, G. K.; Wronska, T.; Kemp, T. J.

    The role of matrix effects in radiolysis and photolysis is illustrated using two systems: organosulphur compounds and benzenediazonium salts. Their intermediates as detected by low temperature ESR and optical spectroscopy or FAB-MS give evidence that the main reaction pathways depend strongly on these effects. Changes in matrix acidity can control the formation of neutral radical, ion-radical or ionic species which are crucial to the character of the final products of irradiation of organosulphur compounds, which are of great importance in medicine, biology, ecology and industry. Microenvironmental influences determine whether the triplet aryl cation or radical species are detected as the principal or sole intermediates in the decomposition of diazonium salts, a process leading to different stable products with industrial application.

  5. A non-equilibrium neutral model for analysing cultural change.

    PubMed

    Kandler, Anne; Shennan, Stephen

    2013-08-07

    Neutral evolution is a frequently used model to analyse changes in frequencies of cultural variants over time. Variants are chosen to be copied according to their relative frequency and new variants are introduced by a process of random mutation. Here we present a non-equilibrium neutral model which accounts for temporally varying population sizes and mutation rates and makes it possible to analyse the cultural system under consideration at any point in time. This framework gives an indication whether observed changes in the frequency distributions of a set of cultural variants between two time points are consistent with the random copying hypothesis. We find that the likelihood of the existence of the observed assemblage at the end of the considered time period (expressed by the probability of the observed number of cultural variants present in the population during the whole period under neutral evolution) is a powerful indicator of departures from neutrality. Further, we study the effects of frequency-dependent selection on the evolutionary trajectories and present a case study of change in the decoration of pottery in early Neolithic Central Europe. Based on the framework developed we show that neutral evolution is not an adequate description of the observed changes in frequency. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Open-access microfluidic patch-clamp array with raised lateral cell trapping sites.

    PubMed

    Lau, Adrian Y; Hung, Paul J; Wu, Angela R; Lee, Luke P

    2006-12-01

    A novel open-access microfluidic patch-clamp array chip with lateral cell trapping sites raised above the bottom plane of the chip was developed by combining both a microscale soft-lithography and a macroscale polymer fabrication method. This paper demonstrates the capability of using such an open-access fluidic system for patch-clamp measurements. The surface of the open-access patch-clamp sites prepared by the macroscale hole patterning method of soft-state elastic polydimethylsiloxane (PDMS) is examined; the seal resistances are characterized and correlated with the aperture dimensions. Whole cell patch-clamp measurements are carried out with CHO cells expressing Kv2.1 ion channels. Kv2.1 ion channel blocker (TEA) dosage response is characterized and the binding activity is examined. The results demonstrate that the system is capable of performing whole cell measurements and drug profiling in a more efficient manner than the traditional patch-clamp set-up.

  7. RNA polymerase pausing and nascent RNA structure formation are linked through clamp domain movement

    PubMed Central

    Hein, Pyae P.; Kolb, Kellie E.; Windgassen, Tricia; Bellecourt, Michael J.; Darst, Seth A.; Mooney, Rachel A.; Landick, Robert

    2014-01-01

    The rates of RNA synthesis and nascent RNA folding into biologically active structures are linked via pausing by RNA polymerase (RNAP). Structures that form within the RNA exit channel can increase pausing by interacting with bacterial RNAP or decrease pausing by preventing backtracking. Conversely, pausing is required for proper folding of some RNAs. Opening of the RNAP clamp domain is proposed to mediate some effects of nascent RNA structures. However, the connections among RNA structure formation, clamp movement, and catalytic activity remain uncertain. We assayed exit-channel structure formation in Escherichia coli RNAP together with disulfide crosslinks that favor closed or open clamp conformations and found that clamp position directly influences RNA structure formation and catalytic activity. We report that exit-channel RNA structures slow pause escape by favoring clamp opening and through interactions with the flap that slow translocation. PMID:25108353

  8. Cell-Detection Technique for Automated Patch Clamping

    NASA Technical Reports Server (NTRS)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.

  9. Finite Element Implementation of Mechanochemical Phenomena in Neutral Deformable Porous Media Under Finite Deformation

    PubMed Central

    Ateshian, Gerard A.; Albro, Michael B.; Maas, Steve; Weiss, Jeffrey A.

    2011-01-01

    Biological soft tissues and cells may be subjected to mechanical as well as chemical (osmotic) loading under their natural physiological environment or various experimental conditions. The interaction of mechanical and chemical effects may be very significant under some of these conditions, yet the highly nonlinear nature of the set of governing equations describing these mechanisms poses a challenge for the modeling of such phenomena. This study formulated and implemented a finite element algorithm for analyzing mechanochemical events in neutral deformable porous media under finite deformation. The algorithm employed the framework of mixture theory to model the porous permeable solid matrix and interstitial fluid, where the fluid consists of a mixture of solvent and solute. A special emphasis was placed on solute-solid matrix interactions, such as solute exclusion from a fraction of the matrix pore space (solubility) and frictional momentum exchange that produces solute hindrance and pumping under certain dynamic loading conditions. The finite element formulation implemented full coupling of mechanical and chemical effects, providing a framework where material properties and response functions may depend on solid matrix strain as well as solute concentration. The implementation was validated using selected canonical problems for which analytical or alternative numerical solutions exist. This finite element code includes a number of unique features that enhance the modeling of mechanochemical phenomena in biological tissues. The code is available in the public domain, open source finite element program FEBio (http://mrl.sci.utah.edu/software). PMID:21950898

  10. Direct Contra Naïve-Indirect Comparison of Clinical Failure Rates between High-Viscosity GIC and Conventional Amalgam Restorations: An Empirical Study

    PubMed Central

    Mickenautsch, Steffen; Yengopal, Veerasamy

    2013-01-01

    Background Naïve-indirect comparisons are comparisons between competing clinical interventions’ evidence from separate (uncontrolled) trials. Direct comparisons are comparisons within randomised control trials (RCTs). The objective of this empirical study is to test the null-hypothesis that trends and performance differences inferred from naïve-indirect comparisons and from direct comparisons/RCTs regarding the failure rates of amalgam and direct high-viscosity glass-ionomer cement (HVGIC) restorations in permanent posterior teeth have similar direction and magnitude. Methods A total of 896 citations were identified through systematic literature search. From these, ten and two uncontrolled clinical longitudinal studies for HVGIC and amalgam, respectively, were included for naïve-indirect comparison and could be matched with three out twenty RCTs. Summary effects sizes were computed as Odds ratios (OR; 95% Confidence intervals) and compared with those from RCTs. Trend directions were inferred from 95% Confidence interval overlaps and direction of point estimates; magnitudes of performance differences were inferred from the median point estimates (OR) with 25% and 75% percentile range, for both types of comparison. Mann-Whitney U test was applied to test for statistically significant differences between point estimates of both comparison types. Results Trends and performance differences inferred from naïve-indirect comparison based on evidence from uncontrolled clinical longitudinal studies and from direct comparisons based on RCT evidence are not the same. The distributions of the point estimates differed significantly for both comparison types (Mann–Whitney U  =  25, nindirect  =  26; ndirect  =  8; p  =  0.0013, two-tailed). Conclusion The null-hypothesis was rejected. Trends and performance differences inferred from either comparison between HVGIC and amalgam restorations failure rates in permanent posterior teeth are not the same. It is recommended that clinical practice guidance regarding HVGICs should rest on direct comparisons via RCTs and not on naïve-indirect comparisons based on uncontrolled longitudinal studies in order to avoid inflation of effect estimates. PMID:24205220

  11. Lotus birth, a holistic approach on physiological cord clamping.

    PubMed

    Zinsser, Laura A

    2018-04-01

    The positive effects of delayed cord clamping (DCC) has been extensively researched. DCC means: waiting at least one minute after birth before clamping and cutting the cord or till the pulsation has stopped. With physiological clamping and cutting (PCC) the clamping and cutting can happen at the earliest after the pulsation has stopped. With a Lotus birth, no clamping and cutting of the cord is done. A woman called Clair Lotus Day imitated the holistic approach of PCC from an anthropoid ape in 1974. The chimpanzee did not separate the placenta from the newborn. The aim of this case report is to discuss and learn a different approach in the third stage of labour. Three cases of Lotus birth by human beings were observed. All three women gave birth in an out-of-hospital setting and had ambulant postnatal care. The placenta was washed, salted and herbs were put on 2-3h post partum. The placenta was wrapped in something that absorbs the moisture. The salting was repeated with a degreasing frequency depending on moistness of the placenta. On life day six all three Lotus babies experiences a natural separation of the cord. All three Lotus birth cases were unproblematic, no special incidence occurred. One should differentiate between early cord clamping (ECC), delayed cord clamping (DCC) and physiological cord clamping (PCC). Lotus birth might lead to an optimisation of the bonding and attachment. Research is needed in the areas of both PCC and Lotus birth. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  12. Molecular mechanism of DNA replication-coupled inactivation of the initiator protein in Escherichia coli: interaction of DnaA with the sliding clamp-loaded DNA and the sliding clamp-Hda complex.

    PubMed

    Su'etsugu, Masayuki; Takata, Makoto; Kubota, Toshio; Matsuda, Yusaku; Katayama, Tsutomu

    2004-06-01

    In Escherichia coli, the ATP-DnaA protein initiates chromosomal replication. After the DNA polymerase III holoenzyme is loaded on to DNA, DnaA-bound ATP is hydrolysed in a manner depending on Hda protein and the DNA-loaded form of the DNA polymerase III sliding clamp subunit, which yields ADP-DnaA, an inactivated form for initiation. This regulatory DnaA-inactivation represses extra initiation events. In this study, in vitro replication intermediates and structured DNA mimicking replicational intermediates were first used to identify structural prerequisites in the process of DnaA-ATP hydrolysis. Unlike duplex DNA loaded with sliding clamps, primer RNA-DNA heteroduplexes loaded with clamps were not associated with DnaA-ATP hydrolysis, and duplex DNA provided in trans did not rescue this defect. At least 40-bp duplex DNA is competent for the DnaA-ATP hydrolysis when a single clamp was loaded. The DnaA-ATP hydrolysis was inhibited when ATP-DnaA was tightly bound to a DnaA box-bearing oligonucleotide. These results imply that the DnaA-ATP hydrolysis involves the direct interaction of ATP-DnaA with duplex DNA flanking the sliding clamp. Furthermore, Hda protein formed a stable complex with the sliding clamp. Based on these, we suggest a mechanical basis in the DnaA-inactivation that ATP-DnaA interacts with the Hda-clamp complex with the aid of DNA binding. Copyright Blackwell Publishing Limited

  13. Listening to the Voice of the Customer.

    ERIC Educational Resources Information Center

    Schauerman, Sam; And Others

    One of the major tenets of Total Quality Management (TQM) is that organizations need to adopt a strong customer focus. At El Camino College (ECC) in Torrance, California, a matrix was developed to identify and describe ECC's direct and indirect internal and external customers. ECC then applied Quality Function Deployment (QFD), a strategic tool…

  14. The semantic differential in landscape research

    Treesearch

    H. E. Echelberger

    1979-01-01

    On-site reactions of groups of viewers to six timber harvesting procedures were measured by direct and indirect measuring techniques. Using the direct technique, groups recorded their overall impressions of harvested tracts on five-point scales ranging from very favorable to very unfavorable. For the indirect technique, semantic differential procedures were used....

  15. Changes in foraminal area with anterior decompression versus keyhole foraminotomy in the cervical spine: a biomechanical investigation.

    PubMed

    Nguyen, Jacqueline; Chu, Bryant; Kuo, Calvin C; Leasure, Jeremi M; Ames, Christopher; Kondrashov, Dimitriy

    2017-12-01

    OBJECTIVE Anterior cervical discectomy and fusion (ACDF) with or without partial uncovertebral joint resection (UVR) and posterior keyhole foraminotomy are established operative procedures to treat cervical disc degeneration and radiculopathy. Studies have demonstrated reliable results with each procedure, but none have compared the change in neuroforaminal area between indirect and direct decompression techniques. The purpose of this study was to determine which cervical decompression method most consistently increases neuroforaminal area and how that area is affected by neck position. METHODS Eight human cervical functional spinal units (4 each of C5-6 and C6-7) underwent sequential decompression. Each level received the following surgical treatment: bilateral foraminotomy, ACDF, ACDF + partial UVR, and foraminotomy + ACDF. Multidirectional pure moment flexibility testing combined with 3D C-arm imaging was performed after each procedure to measure the minimum cross-sectional area of each foramen in 3 different neck positions: neutral, flexion, and extension. RESULTS Neuroforaminal area increased significantly with foraminotomy versus intact in all positions. These area measurements did not change in the ACDF group through flexion-extension. A significant decrease in area was observed for ACDF in extension (40 mm 2 ) versus neutral (55 mm 2 ). Foraminotomy + ACDF did not significantly increase area compared with foraminotomy in any position. The UVR procedure did not produce any changes in area through flexion-extension. CONCLUSIONS All procedures increased neuroforaminal area. Foraminotomy and foraminotomy + ACDF produced the greatest increase in area and also maintained the area in extension more than anterior-only procedures. The UVR procedure did not significantly alter the area compared with ACDF alone. With a stable cervical spine, foraminotomy may be preferable to directly decompress the neuroforamen; however, ACDF continues to play an important role for indirect decompression and decompression of more centrally located herniated discs. These findings pertain to bony stenosis of the neuroforamen and may not apply to soft disc herniation. The key points of this study are as follows. Both ACDF and foraminotomy increase the foraminal space. Foraminotomy was most successful in maintaining these increases during neck motion. Partial UVR was not a significant improvement over ACDF alone. Foraminotomy may be more efficient at decompressing the neuroforamen. Results should be taken into consideration only with stable spines.

  16. Mechanical coupling for a rotor shaft assembly of dissimilar materials

    DOEpatents

    Shi, Jun [Glastonbury, CT; Bombara, David [New Hartford, CT; Green, Kevin E [Broad Brook, CT; Bird, Connic [Rocky Hill, CT; Holowczak, John [South Windsor, CT

    2009-05-05

    A mechanical coupling for coupling a ceramic disc member to a metallic shaft includes a first wedge clamp and a second wedge clamp. A fastener engages a threaded end of a tie-bolt to sandwich the ceramic disc between the wedge clamps. An axial spring is positioned between the fastener and the second wedge clamp to apply an axial preload along the longitudinal axis. Another coupling utilizes a rotor shaft end of a metallic rotor shaft as one wedge clamp. Still another coupling includes a solid ceramic rotor disc with a multiple of tie-bolts radially displaced from the longitudinal axis to exert the preload on the solid ceramic rotor disc.

  17. Laser beam guard clamps

    DOEpatents

    Dickson, Richard K.

    2010-09-07

    A quick insert and release laser beam guard panel clamping apparatus having a base plate mountable on an optical table, a first jaw affixed to the base plate, and a spring-loaded second jaw slidably carried by the base plate to exert a clamping force. The first and second jaws each having a face acutely angled relative to the other face to form a V-shaped, open channel mouth, which enables wedge-action jaw separation by and subsequent clamping of a laser beam guard panel inserted through the open channel mouth. Preferably, the clamping apparatus also includes a support structure having an open slot aperture which is positioned over and parallel with the open channel mouth.

  18. Launch Lock Assemblies with Reduced Preload and Spacecraft Isolation Systems Including the Same

    NASA Technical Reports Server (NTRS)

    Barber, Tim Daniel (Inventor); Young, Ken (Inventor); Hindle, Timothy (Inventor)

    2016-01-01

    Launch lock assemblies with reduced preload are provided. The launch lock assembly comprises first and second mount pieces, a releasable clamp device, and a pair of retracting assemblies. Each retracting assembly comprises a pair of toothed members having interacting toothed surfaces. The releasable clamp device normally maintains the first and second mount pieces in clamped engagement. When the releasable clamp device is actuated, the first and second mount pieces are released from clamped engagement and one toothed member of each retracting assembly moves in an opposite direction relative to the other one toothed member of the other retracting assembly to define an axial gap on each side of the first mount piece.

  19. Internal V-Band Clamp

    DOEpatents

    Vaughn, Mark R.; Hafenrichter, Everett S.; Chapa, Agapito C.; Harris, Steven M.; Martinez, Marcus J.; Baty, Roy S.

    2006-02-28

    A system for clamping two tubular members together in an end-to-end relationship uses a split ring with a V-shaped outer rim that can engage a clamping surface on each member. The split ring has a relaxed closed state where the ends of the ring are adjacent and the outside diameter of the split ring is less than the minimum inside diameter of the members at their ends. The members are clamped when the split ring is spread into an elastically stretched position where the ring rim is pressed tightly against the interior surfaces of the members. Mechanisms are provided for removing the spreader so the split ring will return to the relaxed state, releasing the clamped members.

  20. Potential of Pleurotus ostreatus Mycelium for Selenium Absorption

    PubMed Central

    Milovanović, Ivan; Brčeski, Ilija; Stajić, Mirjana; Korać, Aleksandra; Vukojević, Jelena; Knežević, Aleksandar

    2014-01-01

    The aim of this study was to evaluate the effect of high selenium (Se) concentrations on morphophysiological and ultrastructural properties of Pleurotus ostreatus. Mycelium growth was good in media enriched with 5.0, 10.0, and 20.0 mg L−1 of Se, concentration of 500.0 mg L−1 strongly inhibited growth, and 1000.0 mg L−1 was the minimum inhibitory concentration. Contrary to thin-walled, hyaline, branched, and anastomized hyphae with clamp-connections in the control, at Se concentrations of 100.0 and 500.0 mg L−1, they were noticeably short, frequently septed and branched, with a more intensive extracellular matrix, and without clamp-connections. At high Se concentrations, hyphae with intact membrane, without cellular contents, with a high level of vacuolization, and with numerous proteinaceous bodies were observed. Biomass yield ranged between 11.8 g L−1, in the control, and 6.8 g L−1, at an Se concentration of 100.0 mg L−1, while no production was detected at a concentration of 500.0 mg L−1. Se content in the mycelia reached a peak (938.9 μg g−1) after cultivation in the medium enriched with Se at the concentration of 20.0 mg L−1, while the highest absorption level (53.25%) was found in the medium enriched with 5.0 mg L−1 Se. PMID:25003145

  1. Pipe support

    DOEpatents

    Pollono, Louis P.

    1979-01-01

    A pipe support for high temperature, thin-walled piping runs such as those used in nuclear systems. A section of the pipe to be supported is encircled by a tubular inner member comprised of two walls with an annular space therebetween. Compacted load-bearing thermal insulation is encapsulated within the annular space, and the inner member is clamped to the pipe by a constant clamping force split-ring clamp. The clamp may be connected to pipe hangers which provide desired support for the pipe.

  2. Detection of direct and indirect noise generated by synthetic hot spots in a duct

    NASA Astrophysics Data System (ADS)

    De Domenico, Francesca; Rolland, Erwan O.; Hochgreb, Simone

    2017-04-01

    Sound waves in a combustor are generated from fluctuations in the heat release rate (direct noise) or the acceleration of entropy, vorticity or compositional perturbations through nozzles or turbine guide vanes (indirect or entropy noise). These sound waves are transmitted downstream as well as reflected upstream of the acceleration point, contributing to the overall noise emissions, or triggering combustion instabilities. Previous experiments attempted to isolate indirect noise by generating thermoacoustic hot spots electrically and measuring the transmitted acoustic waves, yet there are no measurements on the backward propagating entropy and acoustic waves. This work presents the first measurements which clearly separate the direct and indirect noise contributions to pressure fluctuations upstream of the acceleration point. Synthetic entropy spots are produced by unsteady electrical heating of a grid of thin wires located in a tube. Compression waves (direct noise) are generated from this heating process. The hot spots are then advected with the mean flow and finally accelerated through an orifice plate located at the end of the tube, producing a strong acoustic signature which propagates upstream (indirect noise). The convective time is selected to be longer than the heating pulse length, in order to obtain a clear time separation between direct and indirect noise in the overall pressure trace. The contribution of indirect noise to the overall noise is shown to be non-negligible either in subsonic or sonic throat conditions. However, the absolute amplitude of direct noise is larger than the corresponding fraction of indirect noise, explaining the difficulty in clearly identifying the two contributions when they are merged. Further, the work shows the importance of using appropriate pressure transducer instrumentation and correcting for the respective transfer functions in order to account for low frequency effects in the determination of pressure fluctuations.

  3. Impact of increasing adherence to disease-modifying therapies on healthcare resource utilization and direct medical and indirect work loss costs for patients with multiple sclerosis.

    PubMed

    Yermakov, Sander; Davis, Matthew; Calnan, Michaela; Fay, Monica; Cox-Buckley, Brieana; Sarda, Sujata; Duh, Mei Sheng; Iyer, Ravi

    2015-01-01

    To estimate the effect of adherence to disease-modifying therapies (DMTs) among patients with multiple sclerosis (MS) on healthcare resource utilization (HRU) and costs, and model the impact of a 10 percentage point increase in adherence on these outcomes. Employed patients, 18-64 years old, with ≥2 MS diagnoses and ≥1 DMT claim during January 1, 2002 to September 30, 2012 were identified from a large commercially-insured US claims database. Adherence was measured as proportion of days covered (PDC) during follow-up. Multivariate regression analyses were conducted to estimate the effect of adherence on HRU related to urgent care (i.e., inpatient or emergency room visit), days of work loss, direct medical cost, and indirect work loss costs. Model coefficients were used to evaluate the impact of a 10 percentage point increase in adherence on the outcomes. A total of 1510 patients were included (mean age = 43.4 years, 64% female). Patients with higher adherence had lower HRU, fewer days of work loss, and lower direct and indirect costs. A 10 percentage point increase in adherence significantly decreased the likelihood of an inpatient or emergency room visit by 9-19%, days of work loss by 3-8%, and direct and indirect costs by 3-5%, depending on the follow-up period (all p < 0.01). Increasing DMT adherence was found to significantly decrease urgent-care HRU, days of work loss, and direct and indirect costs among patients with MS.

  4. Stepwise Regression Analysis of MDOE Balance Calibration Data Acquired at DNW

    NASA Technical Reports Server (NTRS)

    DeLoach, RIchard; Philipsen, Iwan

    2007-01-01

    This paper reports a comparison of two experiment design methods applied in the calibration of a strain-gage balance. One features a 734-point test matrix in which loads are varied systematically according to a method commonly applied in aerospace research and known in the literature of experiment design as One Factor At a Time (OFAT) testing. Two variations of an alternative experiment design were also executed on the same balance, each with different features of an MDOE experiment design. The Modern Design of Experiments (MDOE) is an integrated process of experiment design, execution, and analysis applied at NASA's Langley Research Center to achieve significant reductions in cycle time, direct operating cost, and experimental uncertainty in aerospace research generally and in balance calibration experiments specifically. Personnel in the Instrumentation and Controls Department of the German Dutch Wind Tunnels (DNW) have applied MDOE methods to evaluate them in the calibration of a balance using an automated calibration machine. The data have been sent to Langley Research Center for analysis and comparison. This paper reports key findings from this analysis. The chief result is that a 100-point calibration exploiting MDOE principles delivered quality comparable to a 700+ point OFAT calibration with significantly reduced cycle time and attendant savings in direct and indirect costs. While the DNW test matrices implemented key MDOE principles and produced excellent results, additional MDOE concepts implemented in balance calibrations at Langley Research Center are also identified and described.

  5. Self-aligning fixture used in lathe chuck jaw refacing

    NASA Technical Reports Server (NTRS)

    Linn, C. C.

    1965-01-01

    Self-aligning tool positions and rigidly holds lathe chuck jaws for refacing and truing of the clamping surface. The jaws clamp the fixture in the manner of clamping a workpiece. The fixture can be modified to accommodate four-jawed checks.

  6. The differential effects of emotional salience on direct associative and relational memory during a nap.

    PubMed

    Alger, Sara E; Payne, Jessica D

    2016-12-01

    Relational memories are formed from shared components between directly learned memory associations, flexibly linking learned information to better inform future judgments. Sleep has been found to facilitate both direct associative and relational memories. However, the impact of incorporating emotionally salient information into learned material and the interaction of emotional salience and sleep in facilitating both types of memory is unknown. Participants encoded two sets of picture pairs, with either emotionally negative or neutral objects paired with neutral faces. The same objects were present in both sets, paired with two different faces across the sets. Baseline memory for these directly paired associates was tested immediately after encoding, followed by either a 90-min nap opportunity or wakefulness. Five hours after learning, a surprise test assessed relational memory, the indirect association between two faces paired with the same object during encoding, followed by a retest of direct associative memory. Overall, negative information was remembered better than neutral for directly learned pairs. A nap facilitated both preservation of direct associative memories and formation of relational memories, compared to remaining awake. Interestingly, however, this sleep benefit was observed specifically for neutral directly paired associates, while both neutral and negative relational associations benefitted from a nap. Finally, REM sleep played opposing roles in neutral direct and relational associative memory formation, with more REM sleep leading to forgetting of direct associations but promoting relational associations, suggesting that, while not benefitting memory consolidation for directly learned details, REM sleep may foster the memory reorganization needed for relational memory.

  7. A 6-month follow-up study of posttraumatic stress and anxiety/depressive symptoms in Korean children after direct or indirect exposure to a single incident of trauma.

    PubMed

    Kim, Boong-Nyun; Kim, Jae-Won; Kim, Hyo-Won; Shin, Min-Sup; Cho, Soo-Churl; Choi, Nam Hee; Ahn, Hyunnie; Lee, Seung-Yeon; Ryu, Jeong; Yun, Myoung-Joo

    2009-08-01

    The aims of this study were to examine the symptoms of posttraumatic stress and anxiety/depression in Korean children after direct or indirect exposure to a single incident of trauma during a fire-escape drill and to assess the incidence of psychiatric disorders in this population. A total of 1,394 students who attended the elementary school at which the traumatic event took place were evaluated using self-administered questionnaires (the Child Posttraumatic Stress Disorder-Reaction Index [CPTSD-RI], State Anxiety Scale of the State-Trait Anxiety Inventory for Children [STAIC], and Children's Depression Inventory [CDI]), as well as structured diagnostic interviews (Diagnostic Interview Schedule for Children, Version-IV [DISC-IV]) at 2 days (time point 1), 2 months (time point 2), and 6 months (time point 3) after the incident. The 335 students who witnessed the accident were defined as the direct-exposure group, and the remaining students (n = 1,059) were defined as the indirect-exposure group. The study was conducted from May to November 2007. At time point 1, the prevalence of severe posttraumatic stress disorder (PTSD), anxiety, and depressive symptoms was 18.2%, 5.5%, and 3.4%, respectively. The prevalence of severe PTSD symptoms, as measured by the CPTSD-RI, was significantly higher in the direct-exposure group than in the indirect-exposure group (36.6% vs 12.7%, respectively; P < .001). At time point 2, the prevalence of severe PTSD symptoms was 7.4% (14.0% in the direct-exposure group and 4.9% in the indirect-exposure group, P < .001). The mean total CPTSD-RI score was significantly higher (P < .001) in the direct-exposure group than in the indirect-exposure group. At time point 3, thirty-eight of the 58 subjects (65.5%) evaluated with the DISC-IV in the direct-exposure group had 1 or more of the 7 anxiety/depressive disorders assessed, including subthreshold diagnoses. Among the diagnoses meeting full DSM-IV criteria for each disorder, agoraphobia was the most prevalent (22.4%), followed by generalized anxiety disorder (13.8%), separation anxiety disorder (6.9%), PTSD (5.2%), and social phobia (5.2%). When the subthreshold diagnoses were considered along with the full syndrome diagnoses, separation anxiety disorder was the most common diagnosis (41.4%), followed by agoraphobia (34.5%), obsessive-compulsive disorder (22.4%), PTSD (20.7%), and social phobia (20.7%). The results of this study provide important evidence that various anxiety/depressive disorders, in addition to PTSD, might follow after direct or indirect exposure to trauma. Our findings highlight the importance of comprehensive screening for psychiatric problems in children exposed to trauma of any scale. ©Copyright 2009 Physicians Postgraduate Press, Inc.

  8. Electrically Controlled Coherent Excitonic Steady States in Semiconductor Bilayers

    NASA Astrophysics Data System (ADS)

    Xie, Ming; MacDonald, Allan

    Spatially indirect excitons are long lived bosonic quasiparticles that can form quasi-equilibrium condensed states. Optical access to these excitons has been limited by their small optical matrix elements. Here we propose a promising electrical process that can be used both to populate and to probe fluids of indirect excitons, and is analogous to the crossed Andreev reflection (CAR) process of Cooper pairs in superconductors. We consider vertically stacked multilayer heterostructures containing two transition metal dichalcogenide (TMD) layers that host the indirect excitons, graphene layers on the top and the bottom of the heterostructure, and hBN tunnel barrier layers of variable thickness. When the bias voltage between the graphene leads is smaller than the indirect gap, tunneling between the graphene leads and the TMD hetero-bilayer is possible only through the CAR process. Both DC and low frequency AC bias cases are explored and establish that electrical measurements can be used to determine crucial properties such as the condensate density, interaction strength and CAR tunneling amplitudes. We have also proposed a way to electrically manipulate another type of bosonic quasiparticles, cavity exciton-polaritons, in a laterally contacted structure.

  9. The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA.

    PubMed

    Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku

    2017-01-01

    Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p < 0.001). There was no significant difference between groups B and C ( p = 0.99). The drainage clamping method can be safer than IA-TXA administration in patients with risk factor of venous thromboembolic complication. Furthermore, the IA-TXA administration can be more optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

  10. Substrate Metabolism and Insulin Sensitivity During Fasting in Obese Human Subjects: Impact of GH Blockade.

    PubMed

    Pedersen, Morten Høgild; Svart, Mads Vandsted; Lebeck, Janne; Bidlingmaier, Martin; Stødkilde-Jørgensen, Hans; Pedersen, Steen Bønløkke; Møller, Niels; Jessen, Niels; Jørgensen, Jens O L

    2017-04-01

    Insulin resistance and metabolic inflexibility are features of obesity and are amplified by fasting. Growth hormone (GH) secretion increases during fasting and GH causes insulin resistance. To study the metabolic effects of GH blockade during fasting in obese subjects. Nine obese males were studied thrice in a randomized design: (1) after an overnight fast (control), (2) after 72 hour fasting (fasting), and (3) after 72 hour fasting with GH blockade (pegvisomant) [fasting plus GH antagonist (GHA)]. Each study day consisted of a 4-hour basal period followed by a 2-hour hyperinsulinemic, euglycemic clamp combined with indirect calorimetry, assessment of glucose and palmitate turnover, and muscle and fat biopsies. GH levels increased with fasting (P < 0.01), and the fasting-induced reduction of serum insulin-like growth factor I was enhanced by GHA (P < 0.05). Fasting increased lipolysis and lipid oxidation independent of GHA, but fasting plus GHA caused a more pronounced suppression of lipid intermediates in response to hyperinsulinemic, euglycemic clamp. Fasting-induced insulin resistance was abrogated by GHA (P < 0.01) primarily due to reduced endogenous glucose production (P = 0.003). Fasting plus GHA also caused elevated glycerol levels and reduced levels of counterregulatory hormones. Fasting significantly reduced the expression of antilipolytic signals in adipose tissue independent of GHA. Suppression of GH activity during fasting in obese subjects reverses insulin resistance and amplifies insulin-stimulated suppression of lipid intermediates, indicating that GH is an important regulator of substrate metabolism, insulin sensitivity, and metabolic flexibility also in obese subjects. Copyright © 2017 by the Endocrine Society

  11. Effects of fat on glucose uptake and utilization in patients with non-insulin-dependent diabetes.

    PubMed Central

    Boden, G; Chen, X

    1995-01-01

    It was the aim of this study to determine whether FFA inhibit insulin-stimulated whole body glucose uptake and utilization in patients with non-insulin-dependent diabetes. We performed five types of isoglycemic (approximately 11mM) clamps: (a) with insulin; (b) with insulin plus fat/heparin; (c) with insulin plus glycerol; (d) with saline; (e) with saline plus fat/heparin and two types of euglycemic (approximately 5mM) clamps: (a) with insulin; (b) with insulin plus fat/heparin. During these studies, we determined rates of glucose uptake, glycolysis (both with 3[3H] glucose), glycogen synthesis (determined as glucose uptake minus glycolysis), carbohydrate oxidation (by indirect calorimetry) and nonoxidative glycolysis (determined as glycolysis minus carbohydrate oxidation). Fat/heparin infusion did not affect basal glucose uptake, but inhibited total stimulated (insulin stimulated plus basal) glucose uptake by 40-50% in isoglycemic and in euglycemic patients at plasma FFA concentration of approximately 950 and approximately 550 microM, respectively. In isoglycemic patients, the 40-50% inhibition of total stimulated glucose uptake was due to near complete inhibition of the insulin-stimulated part of glucose uptake. Proportional inhibition of glucose uptake, glycogen synthesis, and glycolysis suggested a major FFA-mediated defect involving glucose transport and/or phosphorylation. In summary, fat produced proportional inhibitions of insulin-stimulated glucose uptake and of intracellular glucose utilization. We conclude, that physiologically elevated levels of FFa could potentially be responsible for a large part of the peripheral insulin resistance in patients with non-insulin-dependent diabetes mellitus. PMID:7657800

  12. Effects of fat on glucose uptake and utilization in patients with non-insulin-dependent diabetes.

    PubMed

    Boden, G; Chen, X

    1995-09-01

    It was the aim of this study to determine whether FFA inhibit insulin-stimulated whole body glucose uptake and utilization in patients with non-insulin-dependent diabetes. We performed five types of isoglycemic (approximately 11mM) clamps: (a) with insulin; (b) with insulin plus fat/heparin; (c) with insulin plus glycerol; (d) with saline; (e) with saline plus fat/heparin and two types of euglycemic (approximately 5mM) clamps: (a) with insulin; (b) with insulin plus fat/heparin. During these studies, we determined rates of glucose uptake, glycolysis (both with 3[3H] glucose), glycogen synthesis (determined as glucose uptake minus glycolysis), carbohydrate oxidation (by indirect calorimetry) and nonoxidative glycolysis (determined as glycolysis minus carbohydrate oxidation). Fat/heparin infusion did not affect basal glucose uptake, but inhibited total stimulated (insulin stimulated plus basal) glucose uptake by 40-50% in isoglycemic and in euglycemic patients at plasma FFA concentration of approximately 950 and approximately 550 microM, respectively. In isoglycemic patients, the 40-50% inhibition of total stimulated glucose uptake was due to near complete inhibition of the insulin-stimulated part of glucose uptake. Proportional inhibition of glucose uptake, glycogen synthesis, and glycolysis suggested a major FFA-mediated defect involving glucose transport and/or phosphorylation. In summary, fat produced proportional inhibitions of insulin-stimulated glucose uptake and of intracellular glucose utilization. We conclude, that physiologically elevated levels of FFa could potentially be responsible for a large part of the peripheral insulin resistance in patients with non-insulin-dependent diabetes mellitus.

  13. Machine-Thermal Coupling Stresses Analysis of the Fin-Type Structural Thermoelectric Generator

    NASA Astrophysics Data System (ADS)

    Zhang, Zheng; Yue, Hao; Chen, Dongbo; Qin, Delei; Chen, Zijian

    2017-05-01

    The design structure and heat-transfer mechanism of a thermoelectric generator (TEG) determine its body temperature state. Thermal stress and thermal deformation generated by the temperature variation directly affect the stress state of thermoelectric modules (TEMs). Therefore, the rated temperature and pressing force of TEMs are important parameters in TEG design. Here, the relationships between structural of a fin-type TEG (FTEG) and these parameters are studied by modeling and "machine-thermal" coupling simulation. An indirect calculation method is adopted in the coupling simulation. First, numerical heat transfer calculations of a three-dimensional FTEG model are conducted according to an orthogonal simulation table. The influences of structural parameters for heat transfer in the channel and outer fin temperature distribution are analyzed. The optimal structural parameters are obtained and used to simulate temperature field of the outer fins. Second, taking the thermal calculation results as the initial condition, the thermal-solid coupling calculation is adopted. The thermal stresses of outer fin, mechanical force of spring-angle pressing mechanism, and clamping force on a TEM are analyzed. The simulation results show that the heat transfer area of the inner fin and the physical parameters of the metal materials are the keys to determining the FTEG temperature field. The pressing mechanism's mechanical force can be reduced by reducing the outer fin angle. In addition, a corrugated cooling water pipe, which has cooling and spring functionality, is conducive to establishing an adaptable clamping force to avoid the TEMs being crushed by the thermal stresses in the body.

  14. Organic–inorganic binary mixture matrix for comprehensive laser-desorption ionization mass spectrometric analysis and imaging of medium-size molecules including phospholipids, glycerolipids, and oligosaccharides

    DOE PAGES

    Feenstra, Adam D.; Ames Lab., Ames, IA; O'Neill, Kelly C.; ...

    2016-10-13

    Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a widely adopted, versatile technique, especially in high-throughput analysis and imaging. However, matrix-dependent selectivity of analytes is often a severe limitation. In this work, a mixture of organic 2,5-dihydroxybenzoic acid and inorganic Fe 3O 4 nanoparticles is developed as a binary MALDI matrix to alleviate the well-known issue of triacylglycerol (TG) ion suppression by phosphatidylcholine (PC). In application to lipid standards and maize seed cross-sections, the binary matrix not only dramatically reduced the ion suppression of TG, but also efficiently desorbed and ionized a wide variety of lipids such as cationic PC, anionicmore » phosphatidylethanolamine (PE) and phosphatidylinositol (PI), and neutral digalactosyldiacylglycerol (DGDG). The binary matrix was also very efficient for large polysaccharides, which were not detected by either of the individual matrices. As a result, the usefulness of the binary matrix is demonstrated in MS imaging of maize seed sections, successfully visualizing diverse medium-size molecules and acquiring high-quality MS/MS spectra for these compounds.« less

  15. Modeling of Elastic Collisions between High Energy and Slow Neutral Atoms

    DTIC Science & Technology

    2015-07-01

    cylindrical test cell, and the currents on the four different electrodes-Inner Cylinder , Exit Plate, Back Aperture, and Collector Plat~were measured...Inner Cylinder electrode. Nevertheless, the neutral atom current to the Inner Cylinder electrode predicted by the VHS model is comparable to the...Figure 9. Normalized curre nt at the Inner Cylinder e lectrode. the point of collision. T he discrepancy in the Exit Plate neutral atom current is due to

  16. Microbiology neutralization of zearalenone using Lactococcus lactis and Bifidobacterium sp.

    PubMed

    Król, A; Pomastowski, P; Rafińska, K; Railean-Plugaru, V; Walczak, J; Buszewski, B

    2018-01-01

    The aim of the study was to neutralize zearalenone by lactic acid bacteria (LAB) such as Lactococcus lactis and Bifidobacterium sp. and investigate the mechanism of zearalenone (ZEA) binding. Neutralization of ZEA by LAB was confirmed by identification of binding kinetics and spectroscopic studies such as Fourier transform infrared spectroscopy (FT-IR) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The obtained results showed that the kinetic process of zearalenone binding to L. lactis is not homogeneous but is expressed with an initial rapid stage with about 90% of ZEA biosorption and with a much slower second step. In case of Bifidobacterium sp., the neutralization process is homogeneous; the main stage can be described with about 88% of ZEA biosorption. MALDI-TOF-MS measurements and FTIR analysis confirmed the uptake of zearalenone molecules by bacterial species. Moreover, the assessment of dead and live lactic acid bacteria cells after zearalenone treatment was performed using fluorescence microscopy. Graphical abstract Microbiology neutralization of zearalenone using Lactococcus lactis and Bifidobacterium sp. was confirmed by identification of binding kinetics and spectroscopic studies such as FT-IR spectroscopy and MALDI-TOF-MS spectrometry. The mechanism of ZEA binding was also investigated.

  17. Temporary clamping of external carotid artery in convexity, parasagittal and temporal base meningioma.

    PubMed

    Yadav, Yad Ram; Parihar, Vijay; Agarwal, Moneet; Bhatele, Pushp Raj

    2012-01-01

    The management of intraoperative bleeding during removal of a large hyper vascular meningioma is crucial for safe and efficient surgery. Preoperative embolization of meningioma is the best way to reduce vascularity of meningiomas but this technique is not readily available, costly and has its own limitations. The study is aimed to evaluate the use of temporary clamping of external carotid artery to reduce blood loss and operating time during excision of large convexity, parasagittal or temporal base meningiomas. A prospective study of 115 consecutively operated meningiomas of size 5 cms or more were operated from January 2002 to December2010. Temporary clamping of external carotid artery was done in 61 while 51 cases were managed without clamping. There was significant reduction of blood loss, operative time and blood transfusion given in the temporary clipping group compared to non clipping group. There was stitch abscess in two patients each in clamping, and non clamping group. There was no scalp necrosis or mortality in any of the group. Temporary clamping of external carotid artery is a safe, simple and cost-effective alternative to embolization for the surgery of large meningiomas. This can be practiced at all the centers.

  18. Measuring true Young's modulus of a cantilevered nanowire: effect of clamping on resonance frequency.

    PubMed

    Qin, Qingquan; Xu, Feng; Cao, Yongqing; Ro, Paul I; Zhu, Yong

    2012-08-20

    The effect of clamping on resonance frequency and thus measured Young's modulus of nanowires (NWs) is systematically investigated via a combined experimental and simulation approach. ZnO NWs are used in this work as an example. The resonance tests are performed in situ inside a scanning electron microscope and the NWs are cantilevered on a tungsten probe by electron-beam-induced deposition (EBID) of hydrocarbon. EBID is repeated several times to deposit more hydrocarbons at the same location. The resonance frequency increases with the increasing clamp size until approaching that under the "fixed" boundary condition. The critical clamp size is identified as a function of NW diameter and NW Young's modulus. This work: 1) exemplifies the importance of considering the effect of clamping in measurements of Young's modulus using the resonance method, and 2) demonstrates that the true Young's modulus can be measured if the critical clamp size is reached. Design guidelines on the critical clamp size are provided. Such design guidelines can be extended to other one-dimensional nanostructures such as carbon nanotubes. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Force-controlled patch clamp of beating cardiac cells.

    PubMed

    Ossola, Dario; Amarouch, Mohamed-Yassine; Behr, Pascal; Vörös, János; Abriel, Hugues; Zambelli, Tomaso

    2015-03-11

    From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.

  20. Peptide- and proton-driven allosteric clamps catalyze anthrax toxin translocation across membranes

    PubMed Central

    Das, Debasis; Krantz, Bryan A.

    2016-01-01

    Anthrax toxin is an intracellularly acting toxin in which sufficient information is available regarding the structure of its transmembrane channel, allowing for detailed investigation of models of translocation. Anthrax toxin, comprising three proteins—protective antigen (PA), lethal factor (LF), and edema factor—translocates large proteins across membranes. Here we show that the PA translocase channel has a transport function in which its catalytic active sites operate allosterically. We find that the phenylalanine clamp (ϕ-clamp), the known conductance bottleneck in the PA translocase, gates as either a more closed state or a more dilated state. Thermodynamically, the two channel states have >300-fold different binding affinities for an LF-derived peptide. The change in clamp thermodynamics requires distant α-clamp and ϕ-clamp sites. Clamp allostery and translocation are more optimal for LF peptides with uniform stereochemistry, where the least allosteric and least efficiently translocated peptide had a mixed stereochemistry. Overall, the kinetic results are in less agreement with an extended-chain Brownian ratchet model but, instead, are more consistent with an allosteric helix-compression model that is dependent also on substrate peptide coil-to-helix/helix-to-coil cooperativity. PMID:27506790

  1. Plasma Chamber Restraints in Ignitor and Relevant Disruption Analysis

    NASA Astrophysics Data System (ADS)

    Gasparotto, M.; Cucchiaro, A.; Capriccioli, A.; Celentano, G.; Rita, C.; Roccella, M.; Macco, B.; Micheli, I.; Ferrari, G.; Orlandi, S.; Coppi, B.

    2000-10-01

    The plasmas chamber (PC) of Ignitor is made of 12 D-shaped toroidal sectors of Inconel 625 welded together by automatic remote equipment. The thickness of the inboard wall is 17 mm while the middle and outboard walls are 26 mm thick. The PC is supported through the ports by the C-Clamp structure of the toroidal magnet. The main function of the PC supports is to resist the vertical and radial electromagnetic loads and to allow for free movement under thermal loads while providing electrical insulation from the C-Clamps and cryostat. The largest estimated loads are due to a Vertical Displacement Event (VDE) disruption that is followed by a thermal quench and then by the current quench. The vertical supports involve a connection of each radial port to the C-Clamp structure by a link system that withstands the calculated loads. The radial supports resist, with high stiffness, the centripetal and centrifugal forces. The end flange of each radial port is connected to the C-Clamp structure by a clamping sleeve device. The clamping sleeves are hydraulically operated to provide locking during discharge. The clamping sleeves of the radial support system have been validated by an appropriate series of tests.

  2. Quick action clamp

    NASA Technical Reports Server (NTRS)

    Calco, Frank S. (Inventor)

    1991-01-01

    A quick release toggle clamp that utilizes a spring that requires a deliberate positive action for disengagement is presented. The clamp has a sliding bolt that provides a latching mechanism. The bolt is moved by a handle that tends to remain in an engaged position while under tension.

  3. Rotary slot dog

    DOEpatents

    Cutburth, Ronald W.; Smauley, David A.

    1987-01-01

    A clamp or dog is disclosed which preferably comprises a slotted stepped cylindrical body which is inserted into a hole in a workpiece and then fastened to a base or fixture using a screw which is inserted through the slot. The stepped configuration provides an annular clamping surface which securely clamps the workpiece against the base or fixture. The slotted cylindrical configuration permits adjustment of the workpiece and retaining clamp in any direction, i.e., over 360.degree., relative to the mounting position of the screw in the base or fixture.

  4. Optical identification of sulfur vacancies: Bound excitons at the edges of monolayer tungsten disulfide

    PubMed Central

    Carozo, Victor; Wang, Yuanxi; Fujisawa, Kazunori; Carvalho, Bruno R.; McCreary, Amber; Feng, Simin; Lin, Zhong; Zhou, Chanjing; Perea-López, Néstor; Elías, Ana Laura; Kabius, Bernd; Crespi, Vincent H.; Terrones, Mauricio

    2017-01-01

    Defects play a significant role in tailoring the optical properties of two-dimensional materials. Optical signatures of defect-bound excitons are important tools to probe defective regions and thus interrogate the optical quality of as-grown semiconducting monolayer materials. We have performed a systematic study of defect-bound excitons using photoluminescence (PL) spectroscopy combined with atomically resolved scanning electron microscopy and first-principles calculations. Spatially resolved PL spectroscopy at low temperatures revealed bound excitons that were present only on the edges of monolayer tungsten disulfide and not in the interior. Optical pumping of the bound excitons was sublinear, confirming their bound nature. Atomic-resolution images reveal that the areal density of monosulfur vacancies is much larger near the edges (0.92 ± 0.45 nm−2) than in the interior (0.33 ± 0.11 nm−2). Temperature-dependent PL measurements found a thermal activation energy of ~36 meV; surprisingly, this is much smaller than the bound-exciton binding energy of ~300 meV. We show that this apparent inconsistency is related to a thermal dissociation of the bound exciton that liberates the neutral excitons from negatively charged point defects. First-principles calculations confirm that sulfur monovacancies introduce midgap states that host optical transitions with finite matrix elements, with emission energies ranging from 200 to 400 meV below the neutral-exciton emission line. These results demonstrate that bound-exciton emission induced by monosulfur vacancies is concentrated near the edges of as-grown monolayer tungsten disulfide. PMID:28508048

  5. Analyses on the geometrical structure of magnetic field in the current sheet based on cluster measurements

    NASA Astrophysics Data System (ADS)

    Shen, C.; Li, X.; Dunlop, M.; Liu, Z. X.; Balogh, A.; Baker, D. N.; Hapgood, M.; Wang, X.

    2003-05-01

    The geometrical structure of the magnetic field is a critical character in the magnetospheric dynamics. Using the magnetic field data measured by the Cluster constellation satellites, the geometrical structure including the curvature radius, directions of curvature, and normal of the osculating planes of the magnetic field lines within the current sheet/neutral sheet have been investigated. The results are (1) Inside of the tail neutral sheet (NS), the curvature of magnetic field lines points towards Earth, the normal of the osculating plane points duskward, and the characteristic half width (or the minimum curvature radius) of the neutral sheet is generally less than 2 RE, for many cases less than 1600 km. (2) Outside of the neutral sheet, the curvature of magnetic field lines pointed northward (southward) at the north (south) side of NS, the normal of the osculating plane points dawnward, and the curvature radius is about 5 RE ˜ 10 RE. (3) Thin NS, where the magnetic field lines have the minimum of the curvature radius less than 0.25 RE, may appear at all the local time between LT 20 hours and 4 hours, but thin NS occurs more frequently near to midnight than that at the dawnside and duskside. (4) The size of the NS is dependent on substorm phases. Generally, the NS is thin during the growth and expansion phases and grows thick during the recovery phase. (5) For the one-dimensional NS, the half thickness and flapping velocity of the NS could be quantitatively determined. Therefore the differential geometry analyses based on Cluster 4-point magnetic measurements open a window for visioning the three-dimensional static and dynamic magnetic field structure of geomagnetosphere.

  6. Advanced control of neutral beam injected power in DIII-D

    DOE PAGES

    Pawley, Carl J.; Crowley, Brendan J.; Pace, David C.; ...

    2017-03-23

    In the DIII-D tokamak, one of the most powerful techniques to control the density, temperature and plasma rotation is by eight independently modulated neutral beam sources with a total power of 20 MW. The rapid modulation requires a high degree of reproducibility and precise control of the ion source plasma and beam acceleration voltage. Recent changes have been made to the controls to provide a new capability to smoothly vary the beam current and beam voltage during a discharge, while maintaining the modulation capability. The ion source plasma inside the arc chamber is controlled through feedback from the Langmuir probesmore » measuring plasma density near the extraction end. To provide the new capability, the plasma control system (PCS) has been enabled to change the Langmuir probe set point and the beam voltage set point in real time. When the PCS varies the Langmuir set point, the plasma density is directly controlled in the arc chamber, thus changing the beam current (perveance) and power going into the tokamak. Alternately, the PCS can sweep the beam voltage set point by 20 kV or more and adjust the Langmuir probe setting to match, keeping the perveance constant and beam divergence at a minimum. This changes the beam power and average neutral particle energy, which changes deposition in the tokamak plasma. The ion separating magnetic field must accurately match the beam voltage to protect the beam line. To do this, the magnet current control accurately tracks the beam voltage set point. In conclusion, these new capabilities allow continuous in-shot variation of neutral beam ion energy to complement« less

  7. Discovery of human scFvs that cross-neutralize the toxic effects of B. jararacussu and C. d. terrificus venoms.

    PubMed

    Silva, Luciano C; Pucca, Manuela B; Pessenda, Gabriela; Campos, Lucas B; Martinez, Edson Z; Cerni, Felipe A; Barbosa, José E

    2018-01-01

    Accidents involving venomous snakes are a public health problem worldwide, causing a large number of deaths per year. In Brazil, the majority of accidents are caused by the Bothrops and Crotalus genera, which are responsible for approximately 80% of severe envenoming cases. The cross-neutralization of snake venoms by antibodies is an important issue for development of more effective treatments. Our group has previously reported the construction of human monoclonal antibody fragments towards Bothrops jararacussu and Crotalus durissus terrificus' venoms. This study aimed to select human single-chain variable fragments (scFvs) that recognize both bothropic and crotalic crude venoms following venoms neutralizing capacity in vitro and in vivo. The cross-reactivity of Cro-Bothrumabs were demonstrated by ELISA and in vitro and in vivo experiments showed that a combination of scFvs neutralizes in vitro toxic activities (e.g. indirect hemolysis and plasma-clotting) of crotalic and bothropic venoms as well as prolonged survival time of envenomed animals. Our results may contribute to the development of the first human polyvalent antivenom against Bothrops jararacussu and Crotalus durissus terrificus venoms, overcoming some undesirable effects caused by conventional serotherapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Mechanics of wafer bonding: Effect of clamping

    NASA Astrophysics Data System (ADS)

    Turner, K. T.; Thouless, M. D.; Spearing, S. M.

    2004-01-01

    A mechanics-based model is developed to examine the effects of clamping during wafer bonding processes. The model provides closed-form expressions that relate the initial geometry and elastic properties of the wafers to the final shape of the bonded pair and the strain energy release rate at the interface for two different clamping configurations. The results demonstrate that the curvature of bonded pairs may be controlled through the use of specific clamping arrangements during the bonding process. Furthermore, it is demonstrated that the strain energy release rate depends on the clamping configuration and that using applied loads usually leads to an undesirable increase in the strain energy release rate. The results are discussed in detail and implications for process development and bonding tool design are highlighted.

  9. Effects of particle size and adaptation duration on the digestible and metabolizable energy contents and digestibility of various chemical constituents in wheat for finishing pigs determined by the direct or indirect method.

    PubMed

    Fan, Yuanfang; Guo, Panpan; Yang, Yuyuan; Xia, Tian; Liu, Ling; Ma, Yongxi

    2017-04-01

    This experiment was conducted as a 3×2×2 factorial design to examine the effects of particle size (mean particle size of 331, 640, or 862 μm), evaluation method (direct vs indirect method) and adaptation duration (7 or 26 days) on the energy content and the apparent total tract digestibility (ATTD) of various chemical components in wheat when fed to finishing pigs. Forty-two barrows (Duroc×Landrace×Yorkshire) with an initial body weight of 63.0±0.8 kg were individually placed in metabolic cages and randomly allotted to 1 of 7 diets with 6 pigs fed each diet. For the indirect method, the pigs were fed either a corn-soybean meal based basal diet or diets in which 38.94% of the basal diet was substituted by wheat of the different particle sizes. In the direct method, the diets contained 97.34% wheat with the different particle sizes. For both the direct and indirect methods, the pigs were adapted to their diets for either 7 or 26 days. A reduction in particle size linearly increased the digestible energy (DE) and metabolizable energy (ME) contents as well as the ATTD of gross energy, crude protein, organic matter, ether extract (EE) and acid detergent fiber (ADF) (p<0.05), and had a trend to increase the ATTD of dry matter of wheat (p = 0.084). The DE, ME contents, and ATTD of gross energy, crude protein, dry matter and organic matter were higher (p<0.05) when determined by the direct method, but the ATTD of ADF, EE, and neutral detergent fiber were higher when determined by the indirect method (p<0.05). Prolongation of the adaption duration decreased the ATTD of neutral detergent fiber (p<0.05) and had a trend to increase the ATTD of EE (p = 0.061). There were no interactions between particle size and the duration of the adaptation duration. The ATTD of EE in wheat was influenced by a trend of interaction between method and adaptation duration (p = 0.074). The ATTD of ADF and EE in wheat was influenced by an interaction between evaluation method and wheat particle size such that there were linear equations (p<0.01) about ATTD of ADF and EE when determined by the direct method but quadratic equations (p = 0.073 and p = 0.088, respectively) about ATTD of ADF and EE when determined by the indirect method. Decreasing particle size can improve the DE and ME contents of wheat; both of the direct and indirect methods of evaluation are suitable for evaluating the DE and ME contents of wheat with different particle sizes; and an adaptation duration of 7 d is sufficient to evaluate DE and ME contents of wheat in finishing pigs.

  10. Lung Matrix Metalloproteinase Activation following Partial Hepatic Ischemia/Reperfusion Injury in Rats

    PubMed Central

    Ferrigno, Andrea; Rizzo, Vittoria; Tarantola, Eleonora

    2014-01-01

    Purpose. Warm hepatic ischemia-reperfusion (I/R) injury can lead to multiorgan dysfunction. The aim of the present study was to investigate whether acute liver I/R does affect the function and/or structure of remote organs such as lung, kidney, and heart via modulation of extracellular matrix remodelling. Methods. Male Sprague-Dawley rats were subjected to 30 min partial hepatic ischemia by clamping the hepatic artery and the portal vein. After a 60 min reperfusion, liver, lung, kidney, and heart biopsies and blood samples were collected. Serum hepatic enzymes, creatinine, urea, Troponin I and TNF-alpha, and tissue matrix metalloproteinases (MMP-2, MMP-9), myeloperoxidase (MPO), malondialdehyde (MDA), and morphology were monitored. Results. Serum levels of hepatic enzymes and TNF-alpha were concomitantly increased during hepatic I/R. An increase in hepatic MMP-2 and MMP-9 activities was substantiated by tissue morphology alterations. Notably, acute hepatic I/R affect the lung inasmuch as MMP-9 activity and MPO levels were increased. No difference in MMPs and MPO was observed in kidney and heart. Conclusions. Although the underlying mechanism needs further investigation, this is the first study in which the MMP activation in a distant organ is reported; this event is probably TNF-alpha-mediated and the lung appears as the first remote organ to be involved in hepatic I/R injury. PMID:24592193

  11. Sputtering of sodium on the planet Mercury

    NASA Technical Reports Server (NTRS)

    Mcgrath, M. A.; Johnson, R. E.; Lanzerotti, L. J.

    1986-01-01

    It is shown here that ion sputtering cannot account for the observed neutral sodium vapor column density on Mercury, but that it is an important loss mechanism for Na. Photons are likely to be the dominant stimulus, both directly through photodesorption and indirectly through thermal desorption of absorbed Na. It is concluded that the atmosphere produced is characterized by the planet's surface temperature, with the ion-sputtered Na contributing to a lesser, but more extended, component of the atmosphere.

  12. Explicit frequency equations of free vibration of a nonlocal Timoshenko beam with surface effects

    NASA Astrophysics Data System (ADS)

    Zhao, Hai-Sheng; Zhang, Yao; Lie, Seng-Tjhen

    2018-02-01

    Considerations of nonlocal elasticity and surface effects in micro- and nanoscale beams are both important for the accurate prediction of natural frequency. In this study, the governing equation of a nonlocal Timoshenko beam with surface effects is established by taking into account three types of boundary conditions: hinged-hinged, clamped-clamped and clamped-hinged ends. For a hinged-hinged beam, an exact and explicit natural frequency equation is obtained. However, for clamped-clamped and clamped-hinged beams, the solutions of corresponding frequency equations must be determined numerically due to their transcendental nature. Hence, the Fredholm integral equation approach coupled with a curve fitting method is employed to derive the approximate fundamental frequency equations, which can predict the frequency values with high accuracy. In short, explicit frequency equations of the Timoshenko beam for three types of boundary conditions are proposed to exhibit directly the dependence of the natural frequency on the nonlocal elasticity, surface elasticity, residual surface stress, shear deformation and rotatory inertia, avoiding the complicated numerical computation.

  13. Non-invasive method and apparatus for measuring pressure within a pliable vessel

    NASA Technical Reports Server (NTRS)

    Shimizu, M. (Inventor)

    1983-01-01

    A non-invasive method and apparatus is disclosed for measuring pressure within a pliable vessel such as a blood vessel. The blood vessel is clamped by means of a clamping structure having a first portion housing a pressure sensor and a second portion extending over the remote side of the blood vessel for pressing the blood vessel into engagement with the pressure sensing device. The pressure sensing device includes a flat deflectable diaphragm portion arranged to engage a portion of the blood vessel flattened against the diaphragm by means of the clamp structure. In one embodiment, the clamp structure includes first and second semicylindrical members held together by retaining rings. In a second embodiment the clamp structure is of one piece construction having a solid semicylindrical portion and a hollow semicylindrical portion with a longitudinal slot in the follow semicylindrical portion through which a slip the blood vessel. In a third embodiment, an elastic strap is employed for clamping the blood vessel against the pressure sensing device.

  14. Term babies with delayed cord clamping: an approach in preventing anemia (.).

    PubMed

    Ertekin, Arif Aktug; Nihan Ozdemir, Nilufer; Sahinoglu, Zeki; Gursoy, Tugba; Erbil, Nazan; Kaya, Erdal

    2016-09-01

    We investigated the effects of delayed and early clamping of the cord on the hematologic status of the baby at birth and at the end of second month. Umbilical cord of 74 babies were clamped in the first 30 s (Group 1) and 76 were clamped at 90-120 s (Group 2). Levels of hemoglobin, hematocrit, iron and ferritin were analyzed from the umbilical cord blood at birth and from the venous samples at the end of second month. Hemoglobin, hematocrit, iron and ferritin levels of cord blood were similar in both groups. However, their levels other than ferritin were higher in Group 2 at the end of second month. Two babies had respiratory distress and twelve neonates received phototherapy in Group 2 whereas only five neonates received phototherapy in Group 1. Term babies to whom delayed cord clamping was performed had improved hematological parameters at the end of second month. Therefore, delaying cord clamping in these babies may be a favorible approach in preventing anemia.

  15. Vibration mode analysis of the proton exchange membrane fuel cell stack

    NASA Astrophysics Data System (ADS)

    Liu, B.; Liu, L. F.; Wei, M. Y.; Wu, C. W.

    2016-11-01

    Proton exchange membrane fuel cell (PEMFC) stacks usually undergo vibration during packing, transportation, and serving time, in particular for those used in the automobiles or portable equipment. To study the stack vibration response, based on finite element method (FEM), a mode analysis is carried out in the present paper. Using this method, we can distinguish the local vibration from the stack global modes, predict the vibration responses, such as deformed shape and direction, and discuss the effects of the clamping configuration and the clamping force magnitude on vibration modes. It is found that when the total clamping force remains the same, increasing the bolt number can strengthen the stack resistance to vibration in the clamping direction, but cannot obviously strengthen stack resistance to vibration in the translations perpendicular to clamping direction and the three axis rotations. Increasing the total clamping force can increase both of the stack global mode and the bolt local mode frequencies, but will decrease the gasket local mode frequency.

  16. Prosthetic helping hand

    NASA Technical Reports Server (NTRS)

    Vest, Thomas W. (Inventor); Carden, James R. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor)

    1992-01-01

    A prosthetic device for below-the-elbow amputees, having a C-shaped clamping mechanism for grasping cylindrical objects, is described. The clamping mechanism is pivotally mounted to a cuff that fits on the amputee's lower arm. The present invention is utilized by placing an arm that has been amputated below the elbow into the cuff. The clamping mechanism then serves as a hand whenever it becomes necessary for the amputee to grasp a cylindrical object such as a handle, a bar, a rod, etc. To grasp the cylindrical object, the object is jammed against the opening in the C-shaped spring, causing the spring to open, the object to pass to the center of the spring, and the spring to snap shut behind the object. Various sizes of clamping mechanisms can be provided and easily interchanged to accommodate a variety of diameters. With the extension that pivots and rotates, the clamping mechanism can be used in a variety of orientations. Thus, this invention provides the amputee with a clamping mechanism that can be used to perform a number of tasks.

  17. Structural Basis of Transcription Inhibition by Fidaxomicin (Lipiarmycin A3).

    PubMed

    Lin, Wei; Das, Kalyan; Degen, David; Mazumder, Abhishek; Duchi, Diego; Wang, Dongye; Ebright, Yon W; Ebright, Richard Y; Sineva, Elena; Gigliotti, Matthew; Srivastava, Aashish; Mandal, Sukhendu; Jiang, Yi; Liu, Yu; Yin, Ruiheng; Zhang, Zhening; Eng, Edward T; Thomas, Dennis; Donadio, Stefano; Zhang, Haibo; Zhang, Changsheng; Kapanidis, Achillefs N; Ebright, Richard H

    2018-04-05

    Fidaxomicin is an antibacterial drug in clinical use for treatment of Clostridium difficile diarrhea. The active ingredient of fidaxomicin, lipiarmycin A3 (Lpm), functions by inhibiting bacterial RNA polymerase (RNAP). Here we report a cryo-EM structure of Mycobacterium tuberculosis RNAP holoenzyme in complex with Lpm at 3.5-Å resolution. The structure shows that Lpm binds at the base of the RNAP "clamp." The structure exhibits an open conformation of the RNAP clamp, suggesting that Lpm traps an open-clamp state. Single-molecule fluorescence resonance energy transfer experiments confirm that Lpm traps an open-clamp state and define effects of Lpm on clamp dynamics. We suggest that Lpm inhibits transcription by trapping an open-clamp state, preventing simultaneous interaction with promoter -10 and -35 elements. The results account for the absence of cross-resistance between Lpm and other RNAP inhibitors, account for structure-activity relationships of Lpm derivatives, and enable structure-based design of improved Lpm derivatives. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Pragma- und textilinguistische Untersuchungsmethoden zur indirekten Rede im Englischen (Pragmatic and Text-Linguistic Research Methods on Indirect Discourse in English)

    ERIC Educational Resources Information Center

    Ziegesar, Detlef von

    1976-01-01

    Examines the mechanisms involved in changing from direct to indirect discourse, taking as a starting point research findings in linguistic pragmatics, which involve the practical application of speech symbol use between speaker and hearer. (Text is in German.) (IFS/WGA)

  19. Phase diagrams of ferroelectric nanocrystals strained by an elastic matrix

    NASA Astrophysics Data System (ADS)

    Nikitchenko, A. I.; Azovtsev, A. V.; Pertsev, N. A.

    2018-01-01

    Ferroelectric crystallites embedded into a dielectric matrix experience temperature-dependent elastic strains caused by differences in the thermal expansion of the crystallites and the matrix. Owing to the electrostriction, these lattice strains may affect polarization states of ferroelectric inclusions significantly, making them different from those of a stress-free bulk crystal. Here, using a nonlinear thermodynamic theory, we study the mechanical effect of elastic matrix on the phase states of embedded single-domain ferroelectric nanocrystals. Their equilibrium polarization states are determined by minimizing a special thermodynamic potential that describes the energetics of an ellipsoidal ferroelectric inclusion surrounded by a linear elastic medium. To demonstrate the stability ranges of such states for a given material combination, we construct a phase diagram, where the inclusion’s shape anisotropy and temperature are used as two parameters. The ‘shape-temperature’ phase diagrams are calculated numerically for PbTiO3 and BaTiO3 nanocrystals embedded into representative dielectric matrices generating tensile (silica glass) or compressive (potassium silicate glass) thermal stresses inside ferroelectric inclusions. The developed phase maps demonstrate that the joint effect of thermal stresses and matrix-induced elastic clamping of ferroelectric inclusions gives rise to several important features in the polarization behavior of PbTiO3 and BaTiO3 nanocrystals. In particular, the Curie temperature displays a nonmonotonic variation with the ellipsoid’s aspect ratio, being minimal for spherical inclusions. Furthermore, the diagrams show that the polarization orientation with respect to the ellipsoid’s symmetry axis is controlled by the shape anisotropy and the sign of thermal stresses. Under certain conditions, the mechanical inclusion-matrix interaction qualitatively alters the evolution of ferroelectric states on cooling, inducing a structural transition in PbTiO3 nanocrystals and suppressing in BaTiO3 inclusions some transformations occurring in their bulk counterpart. The constructed phase maps open the possibility to calculate dielectric properties of strained PbTiO3 and BaTiO3 nanocrystals and ferroelectric nanocomposites comprising such crystallites.

  20. An approximate stationary solution for multi-allele neutral diffusion with low mutation rates.

    PubMed

    Burden, Conrad J; Tang, Yurong

    2016-12-01

    We address the problem of determining the stationary distribution of the multi-allelic, neutral-evolution Wright-Fisher model in the diffusion limit. A full solution to this problem for an arbitrary K×K mutation rate matrix involves solving for the stationary solution of a forward Kolmogorov equation over a (K-1)-dimensional simplex, and remains intractable. In most practical situations mutations rates are slow on the scale of the diffusion limit and the solution is heavily concentrated on the corners and edges of the simplex. In this paper we present a practical approximate solution for slow mutation rates in the form of a set of line densities along the edges of the simplex. The method of solution relies on parameterising the general non-reversible rate matrix as the sum of a reversible part and a set of (K-1)(K-2)/2 independent terms corresponding to fluxes of probability along closed paths around faces of the simplex. The solution is potentially a first step in estimating non-reversible evolutionary rate matrices from observed allele frequency spectra. Copyright © 2016 Elsevier Inc. All rights reserved.

Top