Sample records for night float system

  1. The impact of the night float system on internal medicine residency programs.

    PubMed

    Trontell, M C; Carson, J L; Taragin, M I; Duff, A

    1991-01-01

    To study the design, method of implementation, perceived benefits, and problems associated with a night float system. Self-administered questionnaire completed by program directors, which included both structured and open-ended questions. The answers reflect resident and student opinions as well as those of the program directors, since program directors regularly obtain feedback from these groups. The 442 accredited internal medicine residency programs listed in the 1988-89 Directory of Graduate Medical Education Programs. Of the 442 programs, 79% responded, and 30% had experience with a night float system. The most frequent methods for initiating a night float system included: decreasing elective time (42.3%), hiring more residents (26.9%), creating a non-teaching service (12.5%), and reallocating housestaff time (9.6%). Positive effects cited include decreased fatigue, improved housestaff morale, improved recruiting, and better attitude toward internal medicine training. The quality of medical care was considered the same or better by most programs using it. The most commonly cited problems were decreased continuity of care, inadequate teaching of the night float team, and miscommunication. Residency programs using a night float system usually observe a positive effect on housestaff morale, recruitment, and working hours and no detrimental effect on the quality of patient care. Miscommunication and inadequate learning experience for the night float team are important potential problems. This survey suggests that the night float represents one solution to reducing resident working hours.

  2. An innovative on-call system for paediatric residency programs: The alternate night float.

    PubMed

    Moore, Gregory P; Talarico, Susanna; Kempinska, Anna; Lawrence, Sarah E; Weisz, Dany E

    2015-03-01

    Night-float systems, in which residents work consecutive nights, have been increasingly adopted in paediatric programs, but may be detrimental to residents' sleep and mood. To describe the self-reported impact of a novel system consisting of two consecutive weeks of 16 h overnight shifts every second day that was piloted at the Children's Hospital of Eastern Ontario (Ottawa, Ontario). A survey of 28 senior paediatric residents examined their experience with the alternate night-float system in three domains (patient care, resident professional development and well-being) and their comparison of the system with the traditional overnight on-call system. Twenty-six of 28 residents responded. Nearly all (96%) felt familiar with important details of inpatients and that handover was effective (92%). Results were mixed for professional development, with concerns about the quality of supervisors' feedback and perceived difficulty in attending daytime teaching. All residents believed that the night-float system provided a better learning experience compared with the traditional system. Less than 35% considered fatigue to be a notable problem, although 20% increased use of sleep aids or stimulants beyond their typical use. Ninety-six percent believed their workload was appropriate. All residents felt equally or less fatigued under the night-float system compared with the traditional system. Ninety-six percent recommended that the night-float model continue as the on-call system. This novel night-float system is an alternative method of providing paediatric inpatient night coverage because it meets duty hour regulations and has strong resident approval. Studies to examine its impact on residents and patient care in comparison with other systems are warranted.

  3. Beyond night float? The impact of call structure on internal medicine residents.

    PubMed

    Rosenberg, M; McNulty, D

    1995-02-01

    Limitation of resident working hours has been a critical issue for training programs in recent years. At Providence Medical Center, residents and faculty collaborated in developing goals, implementation strategies, and an evaluation process for a new ward float system. The goals of the float system were to reduce fatigue, facilitate education, maintain continuity of care, and minimize the negative impact of training on residents' personal lives. Evaluation revealed: 1) 74% of the residents preferred Providence Medical Center float system (PMCF) to either night float (NF) (13%) or standard every-fourth-night call (EFNC) (13%); and 2) PMCF was perceived to ensure quality patient care to a greater degree than was NF, to better facilitate resident education than was NF, and to have a less negative impact on personal lives than was EFNC.

  4. Quality of life and educational benefit among orthopedic surgery residents: a prospective, multicentre comparison of the night float and the standard call systems

    PubMed Central

    Zahrai, Ali; Chahal, Jaskarndip; Stojimirovic, Dan; Schemitsch, Emil H.; Yee, Albert; Kraemer, William

    2011-01-01

    Background Given recent evolving guidelines regarding postcall clinical relief of residents and emphasis on quality of life, novel strategies are required for implementing call schedules. The night float system has been used by some institutions as a strategy to decrease the burden of call on resident quality of life in level-1 trauma centres. The purpose of this study was to determine whether there are differences in quality of life, work-related stressors and educational experience between orthopedic surgery residents in the night float and standard call systems at 2 level-1 trauma centres. Methods We conducted a prospective cohort study at 2 level-1 trauma hospitals comprising a standard call (1 night in 4) group and a night float (5 14-hour shifts [5 pm–7 am] from Monday to Friday) group for each hospital. Over the course of a 6-month rotation, each resident completed 3 weeks of night float. The remainder of the time on the trauma service consists of clinical duties from 6:30 am to 5:30 pm on a daily basis and intermittent coverage of weekend call only. Residents completed the Short Form-36 (SF-36) general quality-of-life questionnaire, as well as questionnaires on stress level and educational experience before the rotation (baseline) and at 2, 4 and 6 months. We performed an analysis of covariance to compare between-group differences using the baseline scores as covariates and Wilcoxon signed-rank tests (nonparametric) to determine if the residents’ SF-36 scores were different from the age- and sex-matched Canadian norms. We analyzed predictors of resident quality of life using multivariable mixed models. Results Seven residents were in the standard call group and 9 in the night float group, for a total of 16 residents (all men, mean age 35.1 yr). Controlling for between-group differences at baseline, residents on the night float rotation had significantly lower role physical, bodily pain, social function and physical component scale scores over the 6-month observation period. Compared with the Canadian normative population, the night float group had significantly lower SF-36 scores in all subscales except for bodily pain. There were no differences noted between the standard call group and Canadian norms at 6 months. No differences in educational benefits and stress level were measured between the 2 groups. Lack of time for physical activity was only significant in the night float group. Regression analysis demonstrated that the increased number of hours in hospital correlated with significantly lower SF-36 scores in almost all domains. Conclusion Our study suggests that the residents in the standard call group had better health-related quality of life compared with those in the night float group. No differences existed in subjective educational benefits and stress level between the groups. PMID:21251429

  5. Quality of life and educational benefit among orthopedic surgery residents: a prospective, multicentre comparison of the night float and the standard call systems.

    PubMed

    Zahrai, Ali; Chahal, Jaskarndip; Stojimirovic, Dan; Schemitsch, Emil H; Yee, Albert; Kraemer, William

    2011-02-01

    Given recent evolving guidelines regarding postcall clinical relief of residents and emphasis on quality of life, novel strategies are required for implementing call schedules. The night float system has been used by some institutions as a strategy to decrease the burden of call on resident quality of life in level-1 trauma centres. The purpose of this study was to determine whether there are differences in quality of life, work-related stressors and educational experience between orthopedic surgery residents in the night float and standard call systems at 2 level-1 trauma centres. We conducted a prospective cohort study at 2 level-1 trauma hospitals comprising a standard call (1 night in 4) group and a night float (5 14-hour shifts [5 pm-7 am] from Monday to Friday) group for each hospital. Over the course of a 6-month rotation, each resident completed 3 weeks of night float. The remainder of the time on the trauma service consists of clinical duties from 6:30 am to 5:30 pm on a daily basis and intermittent coverage of weekend call only. Residents completed the Short Form-36 (SF-36) general quality-of-life questionnaire, as well as questionnaires on stress level and educational experience before the rotation (baseline) and at 2, 4 and 6 months. We performed an analysis of covariance to compare between-group differences using the baseline scores as covariates and Wilcoxon signed-rank tests (nonparametric) to determine if the residents' SF-36 scores were different from the age- and sex-matched Canadian norms. We analyzed predictors of resident quality of life using multivariable mixed models. Seven residents were in the standard call group and 9 in the night float group, for a total of 16 residents (all men, mean age 35.1 yr). Controlling for between-group differences at baseline, residents on the night float rotation had significantly lower role physical, bodily pain, social function and physical component scale scores over the 6-month observation period. Compared with the Canadian normative population, the night float group had significantly lower SF-36 scores in all subscales except for bodily pain. There were no differences noted between the standard call group and Canadian norms at 6 months. No differences in educational benefits and stress level were measured between the 2 groups. Lack of time for physical activity was only significant in the night float group. Regression analysis demonstrated that the increased number of hours in hospital correlated with significantly lower SF-36 scores in almost all domains. Our study suggests that the residents in the standard call group had better health-related quality of life compared with those in the night float group. No differences existed in subjective educational benefits and stress level between the groups.

  6. An ACGME Duty Hour Compliant 3-Person Night Float System for Neurological Surgery Residency Programs.

    PubMed

    Ragel, Brian T; Piedra, Mark; Klimo, Paul; Burchiel, Kim J; Waldo, Heidi; McCartney, Shirley; Selden, Nathan R

    2014-06-01

    In 2003, the Accreditation Council for Graduate Medical Education (ACGME) instituted the 24+6-hour work schedule and 80-hour workweek, and in 2011, it enhanced work hour and supervision standards. In response, Oregon Health & Science University's (OHSU) neurological surgery residency instituted a 3-person night float system. We analyzed work hour records and operative experience for 1 year before and after night float implementation in a model that shortened a combined introductory research and basic clinical neurosciences rotation from 12 to 6 months. We analyzed residents' perception of the system using a confidential survey. The ACGME 2011 work hour standards were applied to both time periods. AFTER NIGHT FLOAT IMPLEMENTATION, THE NUMBER OF DUTY HOUR VIOLATIONS WAS REDUCED: 28-hour shift (11 versus 235), 8 hours off between shifts (2 versus 20), 80 hours per week (0 versus 17), and total violations (23 versus 275). Violations increased only for the less than 4 days off per 4-week interval rule (10 versus 3). No meaningful difference was seen in the number of operative cases performed per year at any postgraduate year (PGY) training level: PGY-2 (336 versus 351), PGY-3 (394 versus 354), PGY-4 (803 versus 802), PGY-5 (1075 versus 1040), PGY-7 (947 versus 913), and total (3555 versus 3460). Residents rated the new system favorably. To meet 2011 ACGME duty hour standards, the OHSU neurological surgery residency instituted a 3-person night float system. A nearly complete elimination of work hour violations did not affect overall resident operative experience.

  7. Sleep, activity and fatigue reported by postgraduate year 1 residents: a prospective cohort study comparing the effects of night-float versus traditional overnight on-call.

    PubMed

    Low, Jia Ming; Tan, Mae Yue; See, Kay Choong; Aw, Marion M

    2018-03-19

    As traditional overnight on-call was shown to contribute to fatigue, Singapore moved to implement a shift system in 2014. We aimed to compare activity levels, sleep (using a wrist actigraph), fatigue and professional quality-of-life between residents working on night-float and those working on traditional overnight on-call. All postgraduate year 1 (PGY1) residents at our institution were invited to participate. Participants were required to wear a wrist actigraph for four months, and complete two validated surveys (Epworth Sleepiness Scale [ESS] and Professional Quality of Life Scale [ProQOL]) once each at the start and at the end of study. 49 residents were recruited. Residents on night-float and on-call showed comparable median (range) number of steps (10,061 [1,195-15,923] vs. 10,649 [308-21,910]; p = 0.429), amount of sleep logged (361 [149-630] minutes vs. 380 [175-484] minutes; p = 0.369) and time taken to fall asleep (6 [0-14] minutes vs. 6 [range 0-45] minutes; p = 0.726) respectively. Residents on night-float had less efficient sleep, with 90.5% participants having over 85% sleep efficiency compared to 100% of residents on on-call (p = 0.127). More residents on night-float reported ESS > 10 (73.8% vs. 38.5%) and higher burnout scores on ProQOL (41.4% vs. 21.4%) at the start of the study. However, this was similar to the end of the study and was not statistically significant. The physical activity and amount of sleep of residents on night-float and on-call rota were not significantly different. Residents on night-float reported comparatively higher fatigue and burnout.

  8. Effects of Fatigue on Driving Safety: A Comparison of Brake Reaction Times in Night Float and Postcall Physicians in Training.

    PubMed

    Talusan, Paul G; Long, Theodore; Halim, Andrea; Guliani, Laura; Carroll, Nicole; Reach, John

    2014-12-01

    Concerns about duty hour and resident safety have fostered discussion about postshift fatigue and driving impairment. We assessed how converting to a night float schedule for overnight coverage affected driving safety for trainees. Brake reaction times were measured for internal medicine and orthopaedic surgery resident volunteers after a traditional 28-hour call shift and after a night float shift. We conducted matched paired t tests of preshift and postshift reaction time means. Participants also completed the Epworth Sleepiness Scale pre- and postshift. From June to July 2013, we enrolled 58 interns and residents (28 orthopaedic surgery, 30 internal medicine). We included 24 (41%) trainees on night float rotations and 34 (59%) trainees on traditional 28-hour call shifts. For all residents on night float rotations, there was no significant difference pre- and postshift. An increase in reaction times was noted among trainees on 28-hour call rotations. This included no effect on reaction times for internal medicine trainees pre- and postshift, and an increase in reaction times for orthopaedic trainees. For both night float and traditional call groups, there were significant increases in the Epworth Sleepiness Scale. Trainees on traditional 28-hour call rotations had significantly worse postshift brake reaction times, whereas trainees on night float rotations had no difference. Orthopaedic trainees had significant differences in brake reaction times after a traditional call shift.

  9. Effects of Fatigue on Driving Safety: A Comparison of Brake Reaction Times in Night Float and Postcall Physicians in Training

    PubMed Central

    Talusan, Paul G.; Long, Theodore; Halim, Andrea; Guliani, Laura; Carroll, Nicole; Reach, John

    2014-01-01

    Background Concerns about duty hour and resident safety have fostered discussion about postshift fatigue and driving impairment. Objective We assessed how converting to a night float schedule for overnight coverage affected driving safety for trainees. Methods Brake reaction times were measured for internal medicine and orthopaedic surgery resident volunteers after a traditional 28-hour call shift and after a night float shift. We conducted matched paired t tests of preshift and postshift reaction time means. Participants also completed the Epworth Sleepiness Scale pre- and postshift. Results From June to July 2013, we enrolled 58 interns and residents (28 orthopaedic surgery, 30 internal medicine). We included 24 (41%) trainees on night float rotations and 34 (59%) trainees on traditional 28-hour call shifts. For all residents on night float rotations, there was no significant difference pre- and postshift. An increase in reaction times was noted among trainees on 28-hour call rotations. This included no effect on reaction times for internal medicine trainees pre- and postshift, and an increase in reaction times for orthopaedic trainees. For both night float and traditional call groups, there were significant increases in the Epworth Sleepiness Scale. Conclusions Trainees on traditional 28-hour call rotations had significantly worse postshift brake reaction times, whereas trainees on night float rotations had no difference. Orthopaedic trainees had significant differences in brake reaction times after a traditional call shift. PMID:26140113

  10. Neurohospitalists enhance resident perception of the educational and clinical value of a night float rotation.

    PubMed

    Greene, James G

    2013-10-01

    Neurology residency training programs have been profoundly impacted by recent changes in resident duty hours, workloads, and supervisory requirements. In response, many programs have adopted a night float coverage system to minimize the requirements for overnight call. The majority involves residents working a block of night shifts in what is typically a service-oriented rotation. Recently, concerns have arisen regarding the impact of this design on resident education and patient care. We have developed a novel on-site nighttime neurohospitalist model for the explicit purpose of steepening the initial learning curve for neurology residents in an effort to rapidly improve their neurological skills and, in conjunction, overnight patient care. We surveyed residents after the initiation of this system to assess their perception of the impact of direct overnight supervision on education and patient care. As part of ongoing quality improvement efforts, surveys were administered to neurology house staff at a tertiary academic medical center after they had completed service on the night float rotation both with and without an attending in the hospital using a retrospective pre/postdesign. There was a robust positive impact on resident's perception of overall quality, educational value, and clinical quality on the night float rotation with an attending on-site. Despite an overall perception that their autonomy was maintained, residents believed barriers to contact the attending were lower, and attending interaction during critical decision making was more frequent. Direct overnight supervision by a neurohospitalist enhances the educational value and care quality on overnight resident rotations.

  11. Napping on the Night Shift: A Study of Sleep, Performance, and Learning in Physicians-in-Training.

    PubMed

    McDonald, Jennifer; Potyk, Darryl; Fischer, David; Parmenter, Brett; Lillis, Teresa; Tompkins, Lindsey; Bowen, Angela; Grant, Devon; Lamp, Amanda; Belenky, Gregory

    2013-12-01

    Physicians in training experience fatigue from sleep loss, high workload, and working at an adverse phase of the circadian rhythm, which collectively degrades task performance and the ability to learn and remember. To minimize fatigue and sustain performance, learning, and memory, humans generally need 7 to 8 hours of sleep in every 24-hour period. In a naturalistic, within-subjects design, we studied 17 first- and second-year internal medicine residents working in a tertiary care medical center, rotating between day shift and night float every 4 weeks. We studied each resident for 2 weeks while he/she worked the day shift and for 2 weeks while he/she worked the night float, objectively measuring sleep by wrist actigraphy, vigilance by the Psychomotor Vigilance Task test, and visual-spatial and verbal learning and memory by the Brief Visuospatial Memory Test-Revised and the Rey Auditory-Verbal Learning Test. Residents, whether working day shift or night float, slept approximately 7 hours in every 24-hour period. Residents, when working day shift, consolidated their sleep into 1 main sleep period at night. Residents working night float split their sleep, supplementing their truncated daytime sleep with nighttime on-duty naps. There was no difference in vigilance or learning and memory, whether residents worked day shift or night float. Off-duty sleep supplemented with naps while on duty appears to be an effective strategy for sustaining vigilance, learning, and memory when working night float.

  12. Resident perceptions of the educational value of night float rotations.

    PubMed

    Luks, Andrew M; Smith, C Scott; Robins, Lynne; Wipf, Joyce E

    2010-07-01

    Night float rotations are being increasingly used in the era of resident physician work-hour regulations, but their impact on resident education is not clear. Our objective was to clarify resident perceptions of the educational aspects of night float rotations. An anonymous survey of internal medicine residents at a university-based residency program was completed. Responses were received from 116 of 163 surveyed residents (71%). Residents attended less residents' report (0.10 +/- .43 vs. 2.70 + 0.93 sessions/week, p< .001) and fewer grand rounds sessions (0.14 +/- 0.25 vs. 0.43 +/- 0.28 sessions/week, p< .001) and spent less time reading, (2.63 +/- 2.0 vs. 3.33 +/- 1.6 hr/week, p< .001) interacting with attending physicians (0.57 +/- 1.1 vs. 2.97 +/- 1.5 hr/week, p< .001) and sleeping at home (6.3 +/- 1.2 vs. 7.10 +/- 0.9 hr/day, p< .001) on night float rotations than on non-night float rotations. Residents had strongly negative opinions about the educational value of night float, sleep cycle adjustment issues, and impact on their personal lives, which correlated with resident evaluations from the regular program evaluation process. In free responses, residents commented that they liked the autonomy and opportunity to improve triage skills on these rotations and confirmed their negative opinions about the sleep-wake cycle and interference with personal lives. Internal medicine residents at a university-based program have negative opinions regarding the educational value of night float rotations. Further work is necessary to determine whether problems exist across programs and specialties.

  13. Napping on the Night Shift: A Study of Sleep, Performance, and Learning in Physicians-in-Training

    PubMed Central

    McDonald, Jennifer; Potyk, Darryl; Fischer, David; Parmenter, Brett; Lillis, Teresa; Tompkins, Lindsey; Bowen, Angela; Grant, Devon; Lamp, Amanda; Belenky, Gregory

    2013-01-01

    Background Physicians in training experience fatigue from sleep loss, high workload, and working at an adverse phase of the circadian rhythm, which collectively degrades task performance and the ability to learn and remember. To minimize fatigue and sustain performance, learning, and memory, humans generally need 7 to 8 hours of sleep in every 24-hour period. Methods In a naturalistic, within-subjects design, we studied 17 first- and second-year internal medicine residents working in a tertiary care medical center, rotating between day shift and night float every 4 weeks. We studied each resident for 2 weeks while he/she worked the day shift and for 2 weeks while he/she worked the night float, objectively measuring sleep by wrist actigraphy, vigilance by the Psychomotor Vigilance Task test, and visual-spatial and verbal learning and memory by the Brief Visuospatial Memory Test-Revised and the Rey Auditory-Verbal Learning Test. Results Residents, whether working day shift or night float, slept approximately 7 hours in every 24-hour period. Residents, when working day shift, consolidated their sleep into 1 main sleep period at night. Residents working night float split their sleep, supplementing their truncated daytime sleep with nighttime on-duty naps. There was no difference in vigilance or learning and memory, whether residents worked day shift or night float. Conclusions Off-duty sleep supplemented with naps while on duty appears to be an effective strategy for sustaining vigilance, learning, and memory when working night float. PMID:24455014

  14. Obstetrician call schedule and obstetric outcomes among women eligible for a trial of labor after cesarean.

    PubMed

    Yee, Lynn M; Liu, Lilly Y; Grobman, William A

    2017-01-01

    Reducing cesarean deliveries is a major public health goal. The low rate of vaginal birth after cesarean has been attributed largely to a decrease in the likelihood of choosing a trial of labor after cesarean, despite evidence suggesting a majority of women with 1 prior low transverse cesarean are trial of labor after cesarean candidates. Although a number of reasons for this decrease have been explored, it remains unclear how systems issues such as physician call schedules influence delivery approach and mode in this context. The objective of the study was to investigate the relationship between obstetricians' call schedule and obstetric outcomes among women eligible for a trial of labor after cesarean. This is a retrospective cohort study of the likelihood of attempting a trial of labor after cesarean and achieving vaginal birth after cesarean among women with 1 prior low transverse cesarean delivery and a term, cephalic singleton gestation based on the delivering provider's call schedule. Attending obstetrician call schedules were classified as traditional or night float call. Night float call was defined as a schedule in which the provider had clinical responsibilities only for a day or night shift, without other clinical responsibilities before or after the period of responsibility for laboring patients. Call schedules are determined by individual provider groups. Bivariable analyses and random-effects logistic regression were used to examine the relationship between obstetricians' call schedule and the frequency of trial of labor after cesarean. Secondary outcomes including frequency of vaginal birth after cesarean and maternal and neonatal outcomes also were assessed. Of 1502 eligible patients, 556 (37%) were delivered by physicians in a night float call system. A total of 22.6% underwent a trial of labor after cesarean and 12.8% achieved vaginal birth after cesarean; the vaginal birth after cesarean rate for women attempting a trial of labor after cesarean was 56.5%. Women were more likely to undergo a trial of labor after cesarean (33.1% vs 16.5%, P < .001) and achieve vaginal birth after cesarean (18.7% vs 9.3%, P < .001) when cared for by physicians with a night float call schedule. Regression analyses demonstrated physicians with a night float call schedule remained significantly more likely to have patients undergo trial of labor after cesarean (adjusted odds ratio, 2.64, 95% confidence interval, 1.65-4.25) and experience vaginal birth after cesarean (adjusted odds ratio, 2.17, 95% confidence interval, 1.36-3.45) after adjusting for potential confounders. However, the likelihood of achieving vaginal birth after cesarean if a trial of labor after cesarean was attempted was not different based on provider call type (adjusted odds ratio, 0.96, 95% confidence interval, 0.57-1.62). Although women delivered by providers with a night float schedule were more likely to experience uterine rupture (1.8% vs 0.6%, P = .03), chorioamnionitis (4.3% vs 1.7%, P = .002), postpartum hemorrhage (7.6% vs 4.8%, P = .03), and neonates admitted to the neonatal intensive care unit (6.8% vs 3.9%, P = .01), these associations did not persist when the population was limited to women attempting trial of labor after cesarean. Although physicians working on a night float call system were significantly more likely to have patients with a prior cesarean undergo trial of labor after cesarean and achieve vaginal birth after cesarean, their patients also were more likely to experience maternal and neonatal morbidity. However, these differences did not persist when limiting analyses to women attempting a trial of labor after cesarean. Using a night float call schedule may be an effective measure to promote a trial of labor after cesarean and vaginal birth after cesarean. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Systematic review: association of shift length, protected sleep time, and night float with patient care, residents' health, and education.

    PubMed

    Reed, Darcy A; Fletcher, Kathlyn E; Arora, Vineet M

    2010-12-21

    The Accreditation Council for Graduate Medical Education's new duty-hour standards limit interns' shifts to 16 hours and night float to 6 consecutive nights. Protected sleep time (that is, "nap") is strongly encouraged. As duty-hour reforms are implemented, examination of the quality and outcomes of the relevant literature is important. To systematically review the literature examining shift length, protected sleep time, and night float. MEDLINE, PREMEDLINE, and EMBASE from January 1989 through May 2010. Studies examined the associations of shift length, protected sleep time, or night float with patient care, resident health, and education outcomes among residents in practice settings. Study quality was measured by using the validated Medical Education Research Study Quality Instrument and the U.S. Preventive Services Task Force criteria. Two investigators independently rated study quality, and interrater agreement was calculated. Sixty-four studies met inclusion criteria. Most studies used single-group cross-sectional (19 studies [29.7%]) or pre-post (41 studies [64.1%]) designs, and 4 (6.3%) were randomized, controlled trials. Five studies (7.8%) were multi-institutional. Twenty-four of 33 (72.7%) studies examining shift length reported that shorter shifts were associated with decreased medical errors, motor vehicle crashes, and percutaneous injuries. Only 2 studies assessed protected sleep time and reported that residents' adherence to naps was poor. Night floats described in 33 studies involved 5 to 7 consecutive nights. Most studies used single-institution, observational designs. Publication bias is likely but difficult to assess in this methodologically weak and heterogeneous body of evidence. For the limited outcomes measured, most studies supported reducing shift length but did not adequately address the optimal shift duration. Studies had numerous methodological limitations and unclear generalizability for most outcomes. Specific recommendations about shift length, protected sleep time, and night float should acknowledge the limitations of this evidence. Accreditation Council for Graduate Medical Education.

  16. Impact of around-the-clock in-house cardiology fellow coverage on door-to-balloon time in an academic medical center.

    PubMed

    Kohan, Luke C; Nagarajan, Vijaiganesh; Millard, Michael A; Loguidice, Michael J; Fauber, Nancy M; Keeley, Ellen C

    2017-01-01

    To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI) program. Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B) times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p =0.758), arterial access to first device (12±8 minutes vs 11±7 minutes, p =0.230), or D2B times (50±32 minutes vs 52±34 minutes, p =0.681) during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p =0.007). There was no difference in in-hospital mortality (11% vs 8%, p =0.484) or need for intra-aortic balloon pump placement (7% vs 8%, p =0.793). In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients.

  17. Effect of call organization on burnout and quality of life in psychiatry residents.

    PubMed

    Scarella, Timothy M; Nelligan, Julia; Roberts, Jacqueline; Boland, Robert J

    2017-02-01

    We aimed to measure the effects of a residency program's mid-year shift from 24-h call to night float on resident burnout and quality of life. At the end of the year, residents who started the year with 24-h call had worse burnout and quality of life, with statistical significance and large effect sizes. Exposure to a twenty-four hour call system, when compared to a full year of night float, may be associated with increased burnout and decreased quality of life, though measuring this effect is not straightforward. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A Reduced Duty Hours Model for Senior Internal Medicine Residents: A Qualitative Analysis of Residents' Experiences and Perceptions.

    PubMed

    Mathew, Rebecca; Gundy, Serena; Ulic, Diana; Haider, Shariq; Wasi, Parveen

    2016-09-01

    To assess senior internal medicine residents' experience of the implementation of a reduced duty hours model with night float, the transition from the prior 26-hour call system, and the new model's effects on resident quality of life and perceived patient safety in the emergency department and clinical teaching unit at McMaster University. Qualitative data were collected during May 2013-July 2014, through resident focus groups held prior to implementation of a reduced duty hours model and 10 to 12 months postimplementation. Data analysis was guided by a constructivist grounded theory based in a relativist paradigm. Transcripts were coded; codes were collapsed into themes. Thematic analysis revealed five themes. Residents described reduced fatigue in the early morning, counterbalanced with worsened long-term fatigue on night float blocks; anticipation of negative impacts of the loss of distributed on-call experience and on-call shift volume; an urgency to sleep postcall in anticipation of consecutive night float shifts accompanied by conflicting role demands to stay postcall for care continuity; increased handover frequency accompanied by inaccurate/incomplete communication of patients' issues; and improvement in the senior resident experience on the clinical teaching unit, with increased ownership over patient care and improved relationships with junior housestaff. A reduced duty hours model with night float has potential to improve residents' perceived fatigue on call and care continuity on the clinical teaching unit. This must be weighed against increased handover frequency and loss of the postcall day, which may negatively affect patient care and resident quality of life.

  19. Melatonin treatment of pediatric residents for adaptation to night shift work.

    PubMed

    Cavallo, Anita; Ris, M Douglas; Succop, Paul; Jaskiewicz, Julie

    2005-01-01

    Night float rotations are used in residency training programs to reduce residents' sleep deprivation. Night shift work, however, is accompanied by deleterious effects on sleep, mood, and attention. To test whether melatonin reduces the deleterious effects of night shift work on sleep, mood, and attention in pediatric residents during night float rotation. Double-blind, randomized, placebo-controlled crossover. Participants took melatonin (3 mg) or a placebo before bedtime in the morning after night shift; completed a sleep diary and an adverse-effects questionnaire daily; and completed the Profile of Mood States and the Conners Continuous Performance Test 3 times in each study week to test mood and attention, respectively. A university-affiliated, tertiary-care pediatric hospital. Healthy second-year pediatric residents working 2 night float rotations. Standardized measures of sleep, mood, and attention. Twenty-eight residents completed both treatments; 17 completed 1 treatment (10 placebo, 7 melatonin). There was not a statistically significant difference in measures of sleep, mood, and 5 of 6 measures of attention during melatonin and placebo treatment. One measure of attention, the number of omission errors, was significantly lower on melatonin (3.0 +/- 9.6) than on placebo (4.5 +/- 17.5) (z = -2.12, P = .03). The isolated finding of improvement of 1 single measure of attention in a test situation during melatonin treatment was not sufficiently robust to demonstrate a beneficial effect of melatonin in the dose used. Other strategies need to be considered to help residents in adaptation to night shift work.

  20. Effects of the new Accreditation Council for Graduate Medical Education work hour rules on surgical interns: a prospective study in a community teaching hospital.

    PubMed

    Kamine, Tovy Haber; Barron, Rebecca J; Lesicka, Agnieszka; Galbraith, John D; Millham, Frederick H; Larson, Janet

    2013-02-01

    On July 1, 2011, the Accreditation Council for Graduate Medical Education (ACGME) eliminated 30-hour call in an attempt to improve resident wakefulness. We surveyed interns on the Newton Wellesley Hospital (NWH) surgery service before and after the transition from Q4 overnight call to a night float schedule. For 15 weeks, interns completed weekly surveys including the Epworth Sleepiness Scale (ESS). The service changed to a night float schedule after 3 weeks (ie, first to 3-4 and then to 6 nights in a row). The average ESS score rose from 9.8 ± 5.2 to 14.9 ± 3.1 and 14.4 ± 4.5 (P = .042) on the 3/4 and 6/1 schedules, respectively. Interns were more likely to be abnormally tired on either night float schedule (relative risk = 2.86; 95% confidence interval, 1.17-6.97, P = .029). The new ACGME work hours increased the ESS scores among interns at NWH and caused interns to be more tired than interns on the Q4 schedule. This is likely caused by the multiple nights of poor sleep without a post-call day to make up sleep. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. 33 CFR 175.130 - Visual distress signals accepted.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... red flare (160.024 or 160.036) meets both day and night requirements. Three hand held orange smoke (160.037) with one electric distress light (161.013) meet both day and night requirements. Table 175... Number required 160.021 Hand Held Red Flare Distress Signals 3 Day and Night 3 160.022 Floating Orange...

  2. Development of a Night Float Call Model for Obstetrics and Gynaecology Residency: The Process and Residents' Perceptions.

    PubMed

    Sterling, Lynn; McCaffrey, Carmen; Secter, Michael; Rich, Rebecca; Green, Jessica; Shirreff, Lindsay; Steele, Donna

    2016-11-01

    The 2013 pan-Canadian consensus Report on Resident Duty Hours identified that traditional 24-hour duty periods pose risks to the well-being of residents and should be avoided. In anticipation of duty-hour restrictions, the Obstetrics and Gynaecology Residency Program at the University of Toronto developed and implemented a night float (NF) call model over a three-year span. Quarterly resident surveys have consistently shown that the NF system is preferred to traditional 24-hour call and has resulted in reduced fatigue and improved continuity of patient care. Through many iterations, the NF model achieved levels of resident morale, surgical experience, and impact on family relationships that are comparable to the 24-hour call system. We review here our process for developing an NF call model and the perceptions and experiences of residents, with the goal of providing insight for other residency programs that are considering or instituting NF call systems. Copyright © 2016 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  3. Residents' and attendings' perceptions of a night float system in an internal medicine program in Canada.

    PubMed

    Saxena, Anurag; Desanghere, Loni; Skomro, Robert P; Wilson, Thomas W

    2015-01-01

    The Night Float system (NFS) is often used in residency training programs to meet work hour regulations. The purpose of this study was to examine resident and attendings' perceptions of the NFS on issues of resident learning, well-being, work, non-educational activities and the health care system (patient safety and quality of care, inter-professional teams, workload on attendings and costs of on-call coverage). A survey questionnaire with closed and open-ended questions (26 residents and eight attendings in an Internal Medicine program), informal discussions with the program and moonlighting and financial data were collected. The main findings included, (i) an overall congruency in opinions between resident and attendings across all mean comparisons, (ii) perceptions of improvement for most aspects of resident well-being (e.g. stress, fatigue) and work environment (e.g. supervision, support), (iii) a neutral effect on the resident learning environment, except resident opinions on an increase in opportunities for learning, (iv) perceptions of improved patient safety and quality of care despite worsened continuity of care, and (v) no increases in work-load on attendings or the health care system (cost-neutral call coverage). Patient safety, handovers and increased utilization of moonlighting opportunities need further exploration.

  4. Technical Review and Analysis of Center for Night Vision and Electro-Optics Life Cycle Cost Analysis Model (CNVEO LCCAM),

    DTIC Science & Technology

    1986-09-01

    source of the module/system. Source options are; battery, gas, cartridge, valve , and miscellaneous costs. NAMELIST OPERAT is used to compile the...hardware costs allocated to transportation for packing. TF1 = Initial transportation factor. WEIGHT = Shipping weight of total system. XSUM = System float...CD(6,I)+CD(9,I). . AROC(7,I) - Replenishment spares by year. CD(4,I) - Valve replacement cost by year. CD(5,I) = Cartridge replacement cost by year

  5. Overnight shift work: factors contributing to diagnostic discrepancies.

    PubMed

    Hanna, Tarek N; Loehfelm, Thomas; Khosa, Faisal; Rohatgi, Saurabh; Johnson, Jamlik-Omari

    2016-02-01

    The aims of the study are to identify factors contributing to preliminary interpretive discrepancies on overnight radiology resident shifts and apply this data in the context of known literature to draw parallels to attending overnight shift work schedules. Residents in one university-based training program provided preliminary interpretations of 18,488 overnight (11 pm–8 am) studies at a level 1 trauma center between July 1, 2013 and December 31, 2014. As part of their normal workflow and feedback, attendings scored the reports as major discrepancy, minor discrepancy, agree, and agree--good job. We retrospectively obtained the preliminary interpretation scores for each study. Total relative value units (RVUs) per shift were calculated as an indicator of overnight workload. The dataset was supplemented with information on trainee level, number of consecutive nights on night float, hour, modality, and per-shift RVU. The data were analyzed with proportional logistic regression and Fisher's exact test. There were 233 major discrepancies (1.26 %). Trainee level (senior vs. junior residents; 1.08 vs. 1.38 %; p < 0.05) and modality were significantly associated with performance. Increased workload affected more junior residents' performance, with R3 residents performing significantly worse on busier nights. Hour of the night was not significantly associated with performance, but there was a trend toward best performance at 2 am, with subsequent decreased accuracy throughout the remaining shift hours. Improved performance occurred after the first six night float shifts, presumably as residents acclimated to a night schedule. As overnight shift work schedules increase in popularity for residents and attendings, focused attention to factors impacting interpretative accuracy is warranted.

  6. Depressive-like behavior is elevated among offspring of parents exposed to dim light at night prior to mating.

    PubMed

    Cissé, Yasmine M; Russart, Kathryn L G; Nelson, Randy J

    2017-09-01

    Rates of major depressive disorder (MDD) have steadily increased over the past 50 years. Many factors have been implicated in the etiology of depressive disorders and environmental influences are being increasingly recognized. The increase in depression rates has coincided with increased artificial nighttime lighting. Exposure to light at night (LAN) has been associated with increased depressive-like behavior in rodents and decreased mood in humans. However, relatively little is known on the multigenerational effects of dLAN on affect. In this study, we exposed adult male and female Siberian hamsters (Phodopus sungorus) to either DARK (0lx) or dim LAN (5lx) for 9 weeks, then paired animals in a full factorial design; all animals were thereafter housed in dark nights. Offspring were gestated and reared in dark nights, then tested in adulthood for depressive-like behaviors and hippocampal expression of glucocorticoid (GR) and melatonin (MT1) receptor expression. Maternal exposure to dLAN decreased sucrose preference, time to first float bout in the Porsolt swim test, and GR expression in the hippocampus. Paternal exposure to dLAN increased time spent floating, and increased hippocampal GR expression. Overall, our results suggest that chronic exposure of parents to light at night has multigenerational effects on offspring depressive-like behavior. If these results pertain to humans, then our data suggest that LAN may contribute to the rapidly rising rates of major depressive disorder in industrialized and developing countries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Use of a Night Float System to Comply With Resident Duty Hours Restrictions: Perceptions of Workplace Changes and Their Effects on Professionalism.

    PubMed

    Sun, Ning-Zi; Gan, Runye; Snell, Linda; Dolmans, Diana

    2016-03-01

    Although some evidence suggests that resident duty hours reforms can lead to shift-worker mentality and loss of patient ownership, other evidence links long hours and fatigue to poor work performance and loss of empathy, suggesting the restrictions could positively affect professionalism. The authors explored perceived impacts of a 16-hour duty restriction, achieved using a night float (NF) system, on the workplace and professionalism. In 2013, the authors conducted semistructured interviews with 18 residents, 9 staff physicians, and 3 residency program directors in the McGill University core internal medicine residency program regarding their perceptions of the program's 12-hour shift-based NF system. Interviews were transcribed and coded for common themes. The authors used a descriptive qualitative methodology. Participants viewed implementation of the NF system as leading to decreased physical and mental exhaustion, more consistent interaction with patients, and more stable team structure within shifts compared with the previous 24-hour call system. These workplace changes were felt to improve teamwork and patient ownership within shifts, quality of work performed, and empathy. Across shifts, however, more frequent sign-overs, stricter application of shift time boundaries, and loose integration between daytime and NF teams were perceived as leading to emergence of shift-worker mentality around sign-over. Perceptions of optimal patient ownership changed from the traditional single-physician-24/7 model to team-based shared ownership. Duty hours restrictions, as exemplified by an NF system, have both positive and negative impacts on professionalism. Interventions and training toward effective team-based care are needed to curb emergence of shift-worker mentality.

  8. 33 CFR 149.550 - What are the requirements for lights on a floating hose string?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... least 2 miles (3.7 km) on a clear, dark night; (4) Not less than 1 or more than 3.5 meters (3 to 11.5 feet) above the water; (5) Approximately equally spaced; (6) Not more than 10 meters (32.8 feet) apart... around the horizon; (2) Visible for at least 2 miles (3.7 km) on a clear, dark night; and (3) One meter...

  9. A 360 degrees evaluation of a night-float system for general surgery: a response to mandated work-hours reduction.

    PubMed

    Goldstein, Michael J; Kim, Eugene; Widmann, Warren D; Hardy, Mark A

    2004-01-01

    New York State Code 405 and societal/political pressure have led the RRC and ACGME to mandate strict limitations on resident work hours. In an attempt to meet these limitations, we have switched from the previous Q3 call schedule to a specialized night float (NF) system, the continuity-care system (CCS). The purpose of this CCS is to maximize resident duty time spent on direct patient care, operative experience, and outpatient clinics, while reducing duty hours spent on performing routine tasks and call coverage. The implementation of the CCS is the fundamental step in the restructuring of our residency program. In addition to a change in the call system, we added physician assistants to aid in performing some service tasks. We performed a 360 degrees evaluation of this work in progress. In May 2002, the standard Q3 call system was abolished on the general surgery services at the New York Presbyterian Hospital, Columbia campus. Two dedicated teams were created to provide day and night coverage, a day continuity-care team (DCT) and a night continuity-care team (NCT). The DCTs, consisting of PGY1-5 residents, provide daily in-house coverage from 6 AM to 5 PM with no regular weekday night-call responsibilities. The DCT residents provide Friday night, Saturday, and daytime Sunday call coverage 3 to 4 days per month. The NCT, consisting of 5 PGY1-5 residents, provides nightly continuous care, 5 PM to 6 AM, Sunday through Thursday, with no other weekend call responsibilities. This system creates a schedule with less than 80 duty hours per week, on average, with one 24-hour period off a week, one complete weekend off per month, and no more than 24 hours of consecutive duty time. After 1 year of use, the system was evaluated by a 360 degrees method in which residents, residents' spouses, nurses, and faculty were surveyed using a Likert-type scale. Statistical significance was calculated using the Student t-test. Patient satisfaction was measured both by internal review of a patient complaint database as well as by the Press Ganey patient satisfaction surveys. Twenty-one residents, 10 residents' spouses, 11 general surgery faculty, and 16 nurses were surveyed. Statistically significant findings included reduced resident fatigue noted by all groups (residents, p = 0.01; resident spouses, p = 0.05; faculty, p < 0.0001; nurses, p < 0.0001). Further, residents reported more time for sleep at home (p = 0.0005) and more time for independent reading (p = 0.01). Residents' spouses reported increased availability for family events (p = 0.01). Nurses reported increased availability of residents (p = 0.0002), shorter times to physician identification of patient problems (p = 0.0086), improved resident-nursing communications (p = 0.0096), and increased ease of nursing duties (p < 0.0001). Faculty were the only responders who felt that continuity of patient care suffered with the new system (p = 0.02). The Press Ganey review showed improvement in the quality of care rendered as perceived by patients. The institution of a specialized NF or CCS for in-house coverage of general surgical services in a large metropolitan university hospital has had initial success in meeting the mandated changes in resident work hours. The CCS reduced resident fatigue, improved quality of resident life, and improved patient care as judged by patients and nurse.

  10. Development and optimization of press coated floating pulsatile drug delivery of sumatriptan succinate.

    PubMed

    Jagdale, Swati C; Pawar, Chandrakala R

    2014-01-01

    Floating pulsatile is combined approach designed according to circadian rhythm to deliver the drug at right time, in right quantity and at right site as per pathophysiological need of disease with prolong gastric residence and lag phase followed by burst release. As the migraine follows circadian rhythm in which headache is more painful at the awakening time, the dosage form should be given during night time to release drug when pain get worsen. Present work deals with formulation and optimization of floating pulsatile tablet of sumatriptan succinate. Core tablet containing crospovidone as superdisintegrant (10%) showed burst release. Lag time was maintained using swellable polymer as polyoxN12K and xanthum gum. 3(2) experimental design was carried out. Developed formulations were evaluated for physical characteristics, in vitro and in vivo study. Optimized batch F2 with concentration of polyox N12K (73.43%) and xanthum gum (26.56%) of total polymer weight showed floating lag time 15±2 sec, drug content 99.58±0.2 %, hardness 6±0.2 Kg/cm(2) and drug release 99.54±2% with pulsatile manner followed lag period of 7±0.1h. In vivo x-ray study confirms prolong gastric residence of system. Programmable pulsatile release has been achieved by formulation F2 which meet demand of chronotherapeutic objective of migraine.

  11. Effects of increased overnight supervision on resident education, decision-making, and autonomy.

    PubMed

    Haber, Lawrence A; Lau, Catherine Y; Sharpe, Bradley A; Arora, Vineet M; Farnan, Jeanne M; Ranji, Sumant R

    2012-10-01

    New supervisory regulations highlight the challenge of balancing housestaff supervision and autonomy. To better understand the impact of increased supervision on residency training, we investigated housestaff perceptions of education, autonomy, and clinical decision-making before and after implementation of an in-hospital, overnight attending physician (nocturnist). We established a nocturnist program in July 2010 at our academic, tertiary care medical center. We administered pre-surveys and post-surveys of internal medicine residents on night float rotation during the 2010-2011 academic year. We surveyed residents before and after experiencing the nocturnist program. Housestaff reported an increase in the clinical value of the night float rotation (3.95 vs 4.27, P = 0.01) and the adequacy of overnight supervision (3.65 vs 4.30, P < 0.0001) without a change in decision-making autonomy (4.35 vs 4.45, P = 0.44). Trainees agreed that nocturnist supervision positively impacted patient outcomes (3.79 vs 4.30, P = 0.002). Housestaff contacted attendings more frequently for transfers from outside facilities (2.00 vs 3.20, P = 0.006), during adverse events (2.51 vs 3.25, P = 0.04), prior to ordering invasive diagnostics (1.75 vs 2.76, P = 0.004), and prior to vasopressor use (1.52 vs 2.40, P = 0.004). Residents' fear of revealing knowledge gaps and desire to make decisions independently did not change. Increased overnight supervision enhanced the clinical value of the night float rotation, increased rates of attending contact during critical clinical decision-making, and improved perception of patient care. These changes occurred without a decrease in housestaff's perceived decision-making autonomy. Copyright © 2012 Society of Hospital Medicine.

  12. Applying n-bit floating point numbers and integers, and the n-bit filter of HDF5 to reduce file sizes of remote sensing products in memory-sensitive environments

    NASA Astrophysics Data System (ADS)

    Zinke, Stephan

    2017-02-01

    Memory sensitive applications for remote sensing data require memory-optimized data types in remote sensing products. Hierarchical Data Format version 5 (HDF5) offers user defined floating point numbers and integers and the n-bit filter to create data types optimized for memory consumption. The European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT) applies a compaction scheme to the disseminated products of the Day and Night Band (DNB) data of Suomi National Polar-orbiting Partnership (S-NPP) satellite's instrument Visible Infrared Imager Radiometer Suite (VIIRS) through the EUMETSAT Advanced Retransmission Service, converting the original 32 bits floating point numbers to user defined floating point numbers in combination with the n-bit filter for the radiance dataset of the product. The radiance dataset requires a floating point representation due to the high dynamic range of the DNB. A compression factor of 1.96 is reached by using an automatically determined exponent size and an 8 bits trailing significand and thus reducing the bandwidth requirements for dissemination. It is shown how the parameters needed for user defined floating point numbers are derived or determined automatically based on the data present in a product.

  13. Shifting perceptions: a pre-post study to assess the impact of a senior resident rotation bundle.

    PubMed

    Fabreau, Gabriel; Elliott, Meghan; Khanna, Suneil; Minty, Evan; Wallace, Jean E; de Grood, Jill; Lewin, Adriane; Brown, Garielle; Bharwani, Aleem; Gilmour, Janet; Lemaire, Jane B

    2013-08-29

    Extended duty hours for residents are associated with negative consequences. Strategies to accommodate duty hour restrictions may also have unintended impacts. To eliminate extended duty hours and potentially lessen these impacts, we developed a senior resident rotation bundle that integrates a night float system, educational sessions on sleep hygiene, an electronic handover tool, and a simulation-based medical education curriculum. The aim of this study was to assess internal medicine residents' perceptions of the impact of the bundle on three domains: the senior residents' wellness, ability to deliver quality health care, and medical education experience. This prospective study compared eligible residents' experiences (N = 67) before and after a six-month trial of the bundle at a training program in western Canada. Data was collected using an on-line survey. Pre- and post-intervention scores for the final sample (N = 50) were presented as means and compared using the t-test for paired samples. Participants felt that most aspects of the three domains were unaffected by the introduction of the bundle. Four improved and two worsened perception shifts emerged post-intervention: less exposure to personal harm, reduced potential for medical error, more successful teaching, fewer disruptions to other rotations, increased conflicting role demands and less staff physician supervision. The rotation bundle integrates components that potentially ease some of the perceived negative consequences of night float rotations and duty hour restrictions. Future areas of study should include objective measures of the three domains to validate our study participants' perceptions.

  14. 33 CFR 88.15 - Lights on dredge pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Lights on dredge pipelines. 88.15... NAVIGATION RULES ANNEX V: PILOT RULES § 88.15 Lights on dredge pipelines. Dredge pipelines that are floating or supported on trestles shall display the following lights at night and in periods of restricted...

  15. 33 CFR 88.15 - Lights on dredge pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Lights on dredge pipelines. 88.15... NAVIGATION RULES ANNEX V: PILOT RULES § 88.15 Lights on dredge pipelines. Dredge pipelines that are floating or supported on trestles shall display the following lights at night and in periods of restricted...

  16. 33 CFR 88.15 - Lights on dredge pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Lights on dredge pipelines. 88.15... NAVIGATION RULES ANNEX V: PILOT RULES § 88.15 Lights on dredge pipelines. Dredge pipelines that are floating or supported on trestles shall display the following lights at night and in periods of restricted...

  17. 33 CFR 88.15 - Lights on dredge pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Lights on dredge pipelines. 88.15... NAVIGATION RULES ANNEX V: PILOT RULES § 88.15 Lights on dredge pipelines. Dredge pipelines that are floating or supported on trestles shall display the following lights at night and in periods of restricted...

  18. 33 CFR 88.15 - Lights on dredge pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Lights on dredge pipelines. 88.15... NAVIGATION RULES ANNEX V: PILOT RULES § 88.15 Lights on dredge pipelines. Dredge pipelines that are floating or supported on trestles shall display the following lights at night and in periods of restricted...

  19. Underwater Sound Scattering by Marine Organisms. A Review,

    DTIC Science & Technology

    1979-08-01

    play the dominant scattering role in different seasons . 2.2 Correlation of Acoustic Reverberation Measurements with the Geographic Distribution of...to scattering beneath a floating ice station on the Beaufort Sea. Plankton net hauls indicated that accumulations of the thecostomatous pteropod ...and in the combined upper layer at night. Of these, the siphonophore, Ablyopsis tetragona, pteropod Cymbulia sp.,euphausiids, Thysanopoda sp. and

  20. Perceptions of a group of surgical and non-surgical residents at a Hispanic academic medical center of the impact of the night-float system.

    PubMed

    Colón-de Martí, Luz N; Martínez, Angeles; Gómez, Yolanda; Rivera-Colón, Irma

    2014-06-01

    In 2003 the ACGME implemented mandatory work-hour limitations to address concerns about the negative effects of sleep deprivation on resident wellbeing and patient safety. The night-float system (NFS) is an attempt to promote a balance between optimal patient care and well-rested residents. The aim of this study was to assess and compare the perceptions of surgical and non-surgical residents with regard to the impact of the NFS on their education, their well-being, and aspects related to patient care. After the approval from the Institutional Review Board was received, residents (241) from the UPR School of Medicine residency programs were invited to participate. Those residents who chose to take part in the study (149) completed a questionnaire with demographic questions and items related to individual perceptions of the impact of the NFS. The questionnaires, collected from April 2010 through September 2010, were categorized as having come from a surgical or nonsurgical resident. Data were analyzed. The response rate was almost sixty-two percent (61.8%). Of the residents who answered the questionnaire, 63% were in non-surgical programs, 51% were female, and 58% were single. Seventy-three percent of the residents had participated in an NFS. Sixty-two percent disagreed that their participation in the NFS improved their sense of well-being. Seventy-six percent agreed that their participation improved the continuity of care for the emergency room patients under their responsibility. A higher percentage of the non-surgical residents than surgical residents agreed that during their participation in the NFS, their relationships with their spouses/significant others and children (if applicable), sleep patterns and hours, peer support, and work/ rest balance were impacted negatively. This group of residents presented significant differences between the non-surgical and the surgical groups in areas related to well-being, which the majority agreed was negatively impacted during their participation in the NFS.

  1. Spring bloom onset in the Nordic Seas

    NASA Astrophysics Data System (ADS)

    Mignot, Alexandre; Ferrari, Raffaele; Mork, Kjell Arne

    2016-06-01

    The North Atlantic spring bloom is a massive annual growth event of marine phytoplankton, tiny free-floating algae that form the base of the ocean's food web and generates a large fraction of the global primary production of organic matter. The conditions that trigger the onset of the spring bloom in the Nordic Seas, at the northern edge of the North Atlantic, are studied using in situ data from six bio-optical floats released north of the Arctic Circle. It is often assumed that spring blooms start as soon as phytoplankton cells daily irradiance is sufficiently abundant that division rates exceed losses. The bio-optical float data instead suggest the tantalizing hypothesis that Nordic Seas blooms start when the photoperiod, the number of daily light hours experienced by phytoplankton, exceeds a critical value, independently of division rates. The photoperiod trigger may have developed at high latitudes where photosynthesis is impossible during polar nights and phytoplankton enters into a dormant stage in winter. While the first accumulation of biomass recorded by the bio-optical floats is consistent with the photoperiod hypothesis, it is possible that some biomass accumulation started before the critical photoperiod but at levels too low to be detected by the fluorometers. More precise observations are needed to test the photoperiod hypothesis.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rehder, J.B.

    The project focuses on an appropriate technology for small-scale hydro power: floating waterwheels and turbines. For background, relic and existing systems such as early floating mills, traditional Amish waterwheels, and micro-hydro systems are examined. In the design phase of the project, new designs for Floating Hydro Power Systems include: an analysis of floatation materials and systems; a floating undershot waterwheel design; a floating cylinder (fiberglass storage tank) design; a submerged tube design; and a design for a floating platform with submerged propellers. Finally, in the applications phase, stream flow data from East Tennessee streams are used in a discussion ofmore » the potential applications of floating hydro power systems in small streams.« less

  3. Application of design of experiment for polyox and xanthan gum coated floating pulsatile delivery of sumatriptan succinate in migraine treatment.

    PubMed

    Jagdale, Swati C; Pawar, Chandrakala R

    2014-01-01

    Migraine follows circadian rhythm in which headache is more painful at the awakening time. This needs administration of dosage form at night time to release drug after lag period when pain gets worse. Sumatriptan succinate is a drug of choice for migraine. Sumatriptan succinate has bitter taste, low oral bioavailability, and shorter half-life. Present work deals with application of design of experiment for polyox and xanthan gum in development of press coated floating pulsatile tablet. Floating pulsatile concept was applied to increase gastric residence of the dosage form. Burst release was achieved through immediate release tablet using crospovidone as superdisintegrant (10%). Pulse lag time was achieved using swellable polymer polyox WSR 205 and xanthan gum. 3(2) experimental design was applied. Optimized formulation was evaluated for physical characteristics and in-vitro and in-vivo study. From results, it can be concluded that optimized batch F8 containing polyox WSR205 (72.72%) and xanthan gum (27.27%) of total weight of polymer has shown floating lag time of 55 ± 2 sec, drug content of 100.35 ± 0.4%, hardness of 6 ± 0.1 Kg/cm(2), and 98.69 ± 2% drug release in pulse manner with lag time of 7 ± 0.1 h. Optimized batch showed prolong gastric residence which was confirmed by in-vivo X-ray study.

  4. Search for Low-mass Objects in the Globular Cluster M4. I. Detection of Variable Stars

    NASA Astrophysics Data System (ADS)

    Safonova, M.; Mkrtichian, D.; Hasan, P.; Sutaria, F.; Brosch, N.; Gorbikov, E.; Joseph, P.

    2016-02-01

    With every new discovery of an extrasolar planet, the absence of planets in globular clusters (GCs) becomes more and more conspicuous. Null detection of transiting hot Jupiters in GCs 47 Tuc, ω Cen, and NGC 6397 presents an important puzzle, raising questions about the role played by cluster metallicity and environment on formation and survival of planetary systems in densely populated stellar clusters. GCs were postulated to have many free-floating planets, for which microlensing (ML) is an established tool for detection. Dense environments, well-constrained distances and kinematics of lenses and sources, and photometry of thousands of stars simultaneously make GCs the ideal targets to search for ML. We present first results of a multisite, 69-night-long campaign to search for ML signatures of low-mass objects in the GC M4, which was chosen because of its proximity, location, and the actual existence of a planet. M4 was observed in R and I bands by two telescopes, 1 m T40 and 18-inch C18, of the Wise Observatory, Tel Aviv, Israel, from 2011 April to July. Observations on the 1 m telescope were carried out in service mode, gathering 12 to 48 20 s exposures per night for a total of 69 nights. C18 observations were done for about 4 hr a night for six nights in 2011 May. We employ a semiautomated pipeline to calibrate and reduce the images to the light curves that our group is developing for this purpose, which includes the differential photometry package DIAPL, written by Wozniak and modified by W. Pych. Several different diagnostics are employed for search of variability/transients. While no high-significance ML event was found in this observational run, we have detected more than 20 new variables and variable candidates in the M4 field, which we present here.

  5. Red Sea Outflow Experiment (REDSOX): DLD2 RAFOS Float Data Report February 2001 - March 2003

    DTIC Science & Technology

    2005-01-01

    1 2. Description of the DLD2 Float and Dual-Release System ................................................................... 2 3. Sound Sources...processing are described in detail. 2. Description of the DLD2 Float and Dual-Release System The DLD2 is a second-generation RAFOS (Ranging And Fixing Of...Sound) float with several improvements over the traditional RAFOS float (see Rossby et al., 1986, for a complete description of the RAFOS system ). A

  6. In silico and in vitro methods to optimize the performance of experimental gastroretentive floating mini-tablets.

    PubMed

    Eberle, Veronika A; Häring, Armella; Schoelkopf, Joachim; Gane, Patrick A C; Huwyler, Jörg; Puchkov, Maxim

    2016-01-01

    Development of floating drug delivery systems (FDDS) is challenging. To facilitate this task, an evaluation method was proposed, which allows for a combined investigation of drug release and flotation. It was the aim of the study to use functionalized calcium carbonate (FCC)-based lipophilic mini-tablet formulations as a model system to design FDDS with a floating behavior characterized by no floating lag time, prolonged flotation and loss of floating capability after complete drug release. Release of the model drug caffeine from the mini-tablets was assessed in vitro by a custom-built stomach model. A cellular automata-based model was used to simulate tablet dissolution. Based on the in silico data, floating forces were calculated and analyzed as a function of caffeine release. Two floating behaviors were identified for mini-tablets: linear decrease of the floating force and maintaining of the floating capability until complete caffeine release. An optimal mini-tablet formulation with desired drug release time and floating behavior was developed and tested. A classification system for a range of varied floating behavior of FDDS was proposed. The FCC-based mini-tablets had an ideal floating behavior: duration of flotation is defined and floating capability decreases after completion of drug release.

  7. Potential retention effect at fish farms boosts zooplankton abundance

    NASA Astrophysics Data System (ADS)

    Fernandez-Jover, D.; Toledo-Guedes, K.; Valero-Rodríguez, J. M.; Fernandez-Gonzalez, V.; Sanchez-Jerez, P.

    2016-11-01

    Coastal aquaculture activities influence wild macrofauna in natural environments due to the introduction of artificial structures, such as floating cages, that provide structural complexity in the pelagic system. This alters the abundance and distribution of the affected species and also their feeding behaviour and diet. Despite this, the effects of coastal aquaculture on zooplankton assemblages and the potential changes in their abundance and distribution remain largely unstudied. Traditional plankton sampling hauls between the farm mooring systems entail some practical difficulties. As an alternative, light traps were deployed at 2 farms in the SW Mediterranean during a whole warm season. Total zooplankton capture by traps at farms was higher than at control locations on every sampling night. It ranged from 3 to 10 times higher for the taxonomic groups: bivalvia, cladocera, cumacea, fish early-life-stages, gastropoda, polychaeta and tanaidacea; 10-20 times higher for amphipoda, chaetognatha, isopoda, mysidacea and ostracoda, and 22 times higher for copepoda and the crustacean juvenile stages zoea and megalopa. Permutational analysis showed significant differences for the most abundant zooplankton groups (copepoda, crustacean larvae, chaetognatha, cladocera, mysidacea and polychaeta). This marked incremental increase in zooplankton taxa at farms was consistent, irrespective of the changing environmental variables registered every night. Reasons for the greater abundance of zooplankton at farms are discussed, although results suggest a retention effect caused by cage structures rather than active attraction through physical or chemical cues.

  8. 33 CFR 147.847 - Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety Zone; BW PIONEER Floating... ZONES § 147.847 Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone. (a) Description. The BW PIONEER, a Floating Production, Storage and Offloading (FPSO) system, is in...

  9. Matched filter based detection of floating mines in IR spacetime

    NASA Astrophysics Data System (ADS)

    Borghgraef, Alexander; Lapierre, Fabian; Philips, Wilfried; Acheroy, Marc

    2009-09-01

    Ship-based automatic detection of small floating objects on an agitated sea surface remains a hard problem. Our main concern is the detection of floating mines, which proved a real threat to shipping in confined waterways during the first Gulf War, but applications include salvaging,search-and-rescue and perimeter or harbour defense. IR video was chosen for its day-and-night imaging capability, and its availability on military vessels. Detection is difficult because a rough sea is seen as a dynamic background of moving objects with size order, shape and temperature similar to those of the floating mine. We do find a determinant characteristic in the target's periodic motion, which differs from that of the propagating surface waves composing the background. The classical detection and tracking approaches give bad results when applied to this problem. While background detection algorithms assume a quasi-static background, the sea surface is actually very dynamic, causing this category of algorithms to fail. Kalman or particle filter algorithms on the other hand, which stress temporal coherence, suffer from tracking loss due to occlusions and the great noise level of the image. We propose an innovative approach. This approach uses the periodicity of the objects movement and thus its temporal coherence. The principle is to consider the video data as a spacetime volume similar to a hyperspectral data cube by replacing the spectral axis with a temporal axis. We can then apply algorithms developed for hyperspectral detection problems to the detection of small floating objects. We treat the detection problem using multilinear algebra, designing a number of finite impulse response filters (FIR) maximizing the target response. The algorithm was applied to test footage of practice mines in the infrared.

  10. Application of Design of Experiment for Polyox and Xanthan Gum Coated Floating Pulsatile Delivery of Sumatriptan Succinate in Migraine Treatment

    PubMed Central

    Jagdale, Swati C.; Pawar, Chandrakala R.

    2014-01-01

    Migraine follows circadian rhythm in which headache is more painful at the awakening time. This needs administration of dosage form at night time to release drug after lag period when pain gets worse. Sumatriptan succinate is a drug of choice for migraine. Sumatriptan succinate has bitter taste, low oral bioavailability, and shorter half-life. Present work deals with application of design of experiment for polyox and xanthan gum in development of press coated floating pulsatile tablet. Floating pulsatile concept was applied to increase gastric residence of the dosage form. Burst release was achieved through immediate release tablet using crospovidone as superdisintegrant (10%). Pulse lag time was achieved using swellable polymer polyox WSR 205 and xanthan gum. 32 experimental design was applied. Optimized formulation was evaluated for physical characteristics and in-vitro and in-vivo study. From results, it can be concluded that optimized batch F8 containing polyox WSR205 (72.72%) and xanthan gum (27.27%) of total weight of polymer has shown floating lag time of 55 ± 2 sec, drug content of 100.35 ± 0.4%, hardness of 6 ± 0.1 Kg/cm2, and 98.69 ± 2% drug release in pulse manner with lag time of 7 ± 0.1 h. Optimized batch showed prolong gastric residence which was confirmed by in-vivo X-ray study. PMID:25530963

  11. The Effect of Restricting Residents' Duty Hours on Patient Safety, Resident Well-Being, and Resident Education: An Updated Systematic Review.

    PubMed

    Bolster, Lauren; Rourke, Liam

    2015-09-01

    Despite 25 years of implementation and a sizable amount of research, the impact of resident duty hour restrictions on patients and residents still is unclear. Advocates interpret the research as necessitating immediate change; opponents draw competing conclusions. This study updates a systematic review of the literature on duty hour restrictions conducted 1 year prior to the implementation of the Accreditation Council for Graduate Medical Education's 2011 regulations. The review draws on reports catalogued in MEDLINE and PreMEDLINE from 2010 to 2013. Interventions that dealt with the duty hour restrictions included night float, shortened shifts, and protected time for sleep. Outcomes were patient care, resident well-being, and resident education. Studies were excluded if they were not conducted in patient care settings. Twenty-seven studies met the inclusion criteria. Most frequently, the studies concluded that the restrictions had no impact on patient care (50%) or resident wellness (47%), and had a negative impact on resident education (64%). Night float was the most frequent means of implementing duty hour restrictions, yet it yielded the highest proportion of unfavorable findings. This updated review, including 27 recent applicable studies, demonstrates that focusing on duty hours alone has not resulted in improvements in patient care or resident well-being. The added duty hour restrictions implemented in 2011 appear to have had an unintended negative impact on resident education. New approaches to the issue of physician fatigue and its relationship to patient care and resident education are needed.

  12. Design and in vitro evaluation of multiparticulate floating drug delivery system of zolpidem tartarate.

    PubMed

    Amrutkar, P P; Chaudhari, P D; Patil, S B

    2012-01-01

    Zolpidem tartarate is a non-benzodiazepine, sedative-hypnotic, which finds its major use in various types of insomnia. The present work relates to development of multiparticulate floating drug delivery system based on gas generation technique to prolong the gastric residence time and to increase the overall bioavailability. Modified release dosage form of zolpidem tartarate adapted to release over a predetermined time period, according to biphasic profile of dissolution, where the first phase is immediate release phase for inducing the sleep and the second phase is modified release phase for maintaining the sleep up to 10 h. The system consists of zolpidem tartarate layered pellets coated with effervescent layer and polymeric membrane. The floating ability and in vitro drug release of the system were dependent on amount of the effervescent agent (sodium bicarbonate) layered onto the drug layered pellets, and coating level of the polymeric membrane (Eudragit(®) NE 30D). The system could float completely within 5 min and maintain the floating over a period of 10 h. The multiparticulate floating delivery system of zolpidem tartarate with rapid floating and modified drug release was obtained. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Ocean Observations Below Petermann Gletscher Ice Shelf, Greenland From a Cabled Observatory

    NASA Astrophysics Data System (ADS)

    Muenchow, A.; Nicholls, K. W.; Padman, L.; Washam, P.

    2016-12-01

    Petermann Gletscher in North Greenland features the second largest floating ice shelf by area in the northern hemisphere. In August of 2015 we drilled three holes through the ice shelf and deployed ocean sensors between 5 and 700 m below the glacier-ocean interface. The sensors are controlled by data loggers at the surface that also support a weather station and GPS. All data are transmitted near real-time via a satellite communication link that allowed data downloads and software uploads until February 2016. The system provided gap-free hourly data through the polar night with air temperatures dropping below -48 °C. Mean glacier speeds in winter (Nov.-Feb) were 1180±18 m/year; these values are 12±5% larger than previously reported winter speeds at this location. Hourly ocean observations revealed large bi-monthly pulses within 30 m of the glacier-ocean interface and amplitudes that exceed 1 °C in temperature and 1 psu in salinity. We posit that episodic discharge of glacial meltwater, modulated by the spring-neap tidal cycle thickens the boundary layer under the ice shelf at the location of our measurements. All data are posted at http://ows.udel.edu . A site visit is planned for August 2016 to fix communication failures, retrieve locally stored data, add sensors, and evaluate sustainability of this first cabled observatory on a floating and rapidly melting Greenland glacier.

  14. How is the Department of Veterans Affairs addressing the new Accreditation Council for Graduate Medical Education intern work hour limitations? Solutions from the Association of Veterans Affairs Surgeons.

    PubMed

    Hayman, Amanda V; Tarpley, John L; Berger, David H; Wilson, Mark A; Livingston, Edward H; Kibbe, Melina R

    2012-11-01

    The Accreditation Council for Graduate Medical Education implemented new intern work-hour regulations in July 2011 that have unique implications for surgical training at Veterans Affairs (VA) medical centers. Implementation of these new regulations required profound restructuring of trainee night coverage systems at many VA medical centers. This article offers approaches and potential solutions to the Accreditation Council for Graduate Medical Education regulations used by different surgery programs throughout the country that are applicable to the VA training environment. The information contained in this article was derived from the opinion of a panel of academic surgical leaders in the VA system and responses to a survey that was sent to national VA surgical leaders. The most common solution chosen by the VA centers was hiring physician extenders (37%). The most common type of extender was a nonphysician extender, that is, nurse practitioner or physician assistant (70%), followed by a surgical hospitalist (33%), and surgical resident moonlighter (24%). Other common solutions included the following: night float for residents (22%) or interns (19%), establishing early versus late shifts (19%), or establishing cross-institutional or disciplinary coverage (19%). The public expects the medical community to produce safe, experienced surgeons, while demanding they are well rested and directly supervised at all times. The ability to meet these expectations can be challenging. Published by Elsevier Inc.

  15. Achieving balance on the inpatient internal medicine wards: a performance improvement project to restructure resident work hours at a tertiary care center.

    PubMed

    Cohee, Brian M; Hartzell, Joshua D; Shimeall, William T

    2014-05-01

    In an era of increasing duty hours restrictions, a growing body of literature describes how fatigue and handoffs affect patient care and educational experience. Although many studies examine these elements independently, there remains little understanding of how they interact. Previously reported interventions have yielded unexpected results that are likely dependent on local factors. The authors collected data on admissions, emergency department disposition, and team continuity during an 8-day period before and a 12-day period after changing from a night float system to a resident long-call system with a graded transition to a night team. House staff and attendings were surveyed afterwards. The intervention increased the portion of patients admitted to their primary resident from 47% (43/91) to 82% (75/91) (P < .01) and improved the percentage of emergency room admissions performed in less than 90 minutes from 39% (7/18) to 70% (39/44) (P = .02). The percentage of self-reported duty hours violations decreased from 55% (16/29) to 6.8% (3/44) (P < .01). Survey respondents reported an improved sense of patient involvement, quality of care, and handoffs. Designing a call system around a brief assessment of admission intensity resulted in better alignment of resident resources with workload and improvements in multiple outcomes. Optimization of inpatient work structure appears to be significantly affected by local factors. Future trials assessing work hour balance will need to take work intensity into account and assess a wide variety of potential consequences.

  16. Floating drug delivery systems: a review.

    PubMed

    Arora, Shweta; Ali, Javed; Ahuja, Alka; Khar, Roop K; Baboota, Sanjula

    2005-10-19

    The purpose of writing this review on floating drug delivery systems (FDDS) was to compile the recent literature with special focus on the principal mechanism of floatation to achieve gastric retention. The recent developments of FDDS including the physiological and formulation variables affecting gastric retention, approaches to design single-unit and multiple-unit floating systems, and their classification and formulation aspects are covered in detail. This review also summarizes the in vitro techniques, in vivo studies to evaluate the performance and application of floating systems, and applications of these systems. These systems are useful to several problems encountered during the development of a pharmaceutical dosage form.

  17. Validation of Ionospheric Measurements from the International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Coffey, Victoria; Minow, Joseph; Wright, Kenneth

    2009-01-01

    The International Space Station orbit provides an ideal platform for in-situ studies of space weather effects on the mid and low-latitude F-2 region ionosphere. The Floating Potential Measurement Unit (FPMU) operating on the ISS since Aug 2006, is a suite of plasma instruments: a Floating Potential Probe (FPP), a Plasma Impedance Probe (PIP), a Wide-sweep Langmuir Probe (WLP), and a Narrow-Sweep Langmuir Probe. This instrument package provides a new opportunity for collaborative multi-instrument studies of the F-region ionosphere during both quiet and disturbed periods. This presentation first describes the operational parameters for each of the FPMU probes and shows examples of an intra-instrument validation. We then show comparisons with the plasma density and temperature measurements derived from the TIMED GUVI ultraviolet imager, the Millstone Hill ground based incoherent scatter radar, and DIAS digisondes, Finally we show one of several observations of night-time equatorial density holes demonstrating the capabilities of the probes for monitoring mid and low latitude plasma processes.

  18. In-situ Observations of the Ionospheric F2-Region from the International Space Station

    NASA Technical Reports Server (NTRS)

    Coffey, Victoria N.; Wright, Kenneth H.; Minow, Joseph I.; Chandler, Michael O.; Parker, Linda N.

    2008-01-01

    The International Space Station orbit provides an ideal platform for in-situ studies of space weather effects on the mid and low latitude F-2 region ionosphere. The Floating Potential Measurement Unit (FPMU) operating on the ISS since Aug 2006, is a suite of plasma instruments: a Floating Potential Probe (FPP), a Plasma Impedance Probe (PIP), a Wide-sweep Langmuir Probe (WLP), and a Narrow-sweep Langmuir Probe (NLP). This instrument package provides a new opportunity for collaborative multi-instrument studies of the F-region ionosphere during both quiet and disturbed periods. This presentation first describes the operational parameters for each of the FPMU probes and shows examples of an intra-instrument validation. We then show comparisons with the plasma density and temperature measurements derived from the TIMED GUVI ultraviolet imager, the Millstone Hill ground based incoherent scatter radar, and DIAS digisondes, Finally we show one of several observations of night-time equatorial density holes demonstrating the capabilities of the probes for monitoring mid and low latitude plasma processes.

  19. Definition of the Semisubmersible Floating System for Phase II of OC4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, A.; Jonkman, J.; Masciola, M.

    Phase II of the Offshore Code Comparison Collaboration Continuation (OC4) project involved modeling of a semisubmersible floating offshore wind system as shown below. This report documents the specifications of the floating system, which were needed by the OC4 participants for building aero-hydro-servo-elastic models.

  20. Electrowetting in a water droplet with a movable floating substrate

    NASA Astrophysics Data System (ADS)

    Shahzad, Amir; Masud, A. R.; Song, Jang-Kun

    2016-05-01

    Electrowetting (EW) enables facile manipulation of a liquid droplet on a hydrophobic surface. In this study, manipulation of an electrolyte droplet having a small floating object on it was investigated on a solid hydrophobic substrate under the EW process. Herein, the floating object exhibited a vertical motion under an applied electric field owing to the spreading and contraction of the droplet on its connecting substrates. The field-induced height variation of the floating object was significantly influenced by the thicknesses of the dielectric and hydrophobic materials. A small mass was also placed on the top floating object and its effect on the spreading of the droplet was observed. In this system, the height of the top floating object is precisely controllable under the application of an electric voltage. The proposed system is expected to be highly useful in the design of nano- and micro-oscillatory systems for microengineering.

  1. Electrowetting in a water droplet with a movable floating substrate.

    PubMed

    Shahzad, Amir; Masud, A R; Song, Jang-Kun

    2016-05-01

    Electrowetting (EW) enables facile manipulation of a liquid droplet on a hydrophobic surface. In this study, manipulation of an electrolyte droplet having a small floating object on it was investigated on a solid hydrophobic substrate under the EW process. Herein, the floating object exhibited a vertical motion under an applied electric field owing to the spreading and contraction of the droplet on its connecting substrates. The field-induced height variation of the floating object was significantly influenced by the thicknesses of the dielectric and hydrophobic materials. A small mass was also placed on the top floating object and its effect on the spreading of the droplet was observed. In this system, the height of the top floating object is precisely controllable under the application of an electric voltage. The proposed system is expected to be highly useful in the design of nano- and micro-oscillatory systems for microengineering.

  2. Definition of the Floating System for Phase IV of OC3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jonkman, J.

    Phase IV of the IEA Annex XXIII Offshore Code Comparison Collaboration (OC3) involves the modeling of an offshore floating wind turbine. This report documents the specifications of the floating system, which are needed by the OC3 participants for building aero-hydro-servo-elastic models.

  3. First measurements with Argo flots in the Southern Baltic Sea

    NASA Astrophysics Data System (ADS)

    Walczowski, Waldemar; Goszczko, Ilona; Wieczorek, Piotr; Merchel, Malgorzata; Rak, Daniel

    2017-04-01

    The Argo programme is one of the most important elements of the ocean observing system. Currently almost 4000 Argo floats profile global oceans and deliver real time data. Originally Argo floats were developed for open ocean observations. Therefore a standard float can dive up to 2000 m and deep Argo floats are under development. However in the last years the shallow shelf seas become also interesting for Argo users. Institute of Oceanology Polish Academy of Sciences (IOPAN) participates in the Euro-Argo research infrastructure, the European contribution to Argo system. A legal and governance framework (Euro-Argo ERIC) was set up in May 2014. For a few years IOPAN has deployed floats mostly in the Nordic Seas and the European Arctic region. In the end of 2016 the first Polish Argo float was deployed in the Southern Baltic Sea. Building on the successful experience with Argo floats deployed by the Finnish oceanographers in the Bothnian Sea and Gotland Basin, the IOPAN float was launched in the Bornholm Deep during the fall cruise of IOPAN research vessel Oceania. The standard APEX float equipped with 2-way Iridium communication was used and different modes of operation, required for the specific conditions in the shallow and low saline Baltic Sea, were tested. Settings for the Baltic float are different than for the oceanic mode and were frequently changed during the mission to find the optimum solution. Changing the float parking depth during the mission allows for the limited control of the float drift direction. Results of a high resolution numerical forecast model for the Baltic Sea proved to be a valuable tool for determining the parking depth of the float in the different flow regimes. Trajectory and drift velocity of the Argo float deployed in the Southern Baltic depended strongly on the atmospheric forcing (in particular wind speed and direction), what was clearly manifested during the 'Axel' storm passing over the deployment area in January 2017. The first deployment showed clearly that Argo floats can be a useful tool for the Baltic Sea monitoring as the important element of a more complex, multidisciplinary observing system.

  4. Collective Behavior of Camphor Floats Migrating on the Water Surface

    NASA Astrophysics Data System (ADS)

    Nishimori, Hiraku; Suematsu, Nobuhiko J.; Nakata, Satoshi

    2017-10-01

    As simple and easily controllable objects among various self-propelled particles, camphor floats on the water surface have been widely recognized. In this paper, we introduce characteristic behaviors and discuss the background mechanism of camphor floats on water, both in isolated and non-isolated conditions. In particular, we focus on: (i) the transition of dynamical characters through bifurcations exhibited by systems with small number of camphor floats and (ii) the emergence of a rich variety of complex dynamics observed in systems with large number camphor floats, and attempt to elucidate these phenomena through mathematical modeling as well as experimental analysis. Finally, we discuss the connection of the dynamics of camphor floats to that of a wider class of complex and sophisticated dynamics exhibited by various types of self-propelled particles.

  5. Astronauts Capture Moon Illusion Photo

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Many odd looking moon photos have been captured over the years by astronauts aboard the International Space Station. Even so, this photograph, taken by the crew over Russia on May 11, 2003, must have come as a surprise. The moon which is really a quarter of a million miles away, appears to be floating inside the Earth's atmosphere. The picture is tricky because of its uneven lighting. With the sun's elevation angle at only 6 degrees, night is falling on the left side of the image while it is still broad daylight on the right side. This gradient of sunlight is the key to the illusion.

  6. Earth Observations taken by the Expedition Seven crew

    NASA Image and Video Library

    2003-05-11

    ISS007-E-05379 (11 May 2003) --- The moon seems to be floating inside Earth’s atmosphere as it was photographed by an Expedition 7 crewmember onboard the International Space Station (ISS) while above Russia. It’s an illusion, of course. The moon is really a quarter of a million miles away. The picture is tricky because of its uneven lighting. The sun’s elevation angle is only 6 degrees. On the left side of the image, night is falling; on the right side, it’s still broad daylight. This gradient of sunlight is the key to the illusion.

  7. International Space Station (ISS)

    NASA Image and Video Library

    2003-05-11

    Many odd looking moon photos have been captured over the years by astronauts aboard the International Space Station. Even so, this photograph, taken by the crew over Russia on May 11, 2003, must have come as a surprise. The moon which is really a quarter of a million miles away, appears to be floating inside the Earth's atmosphere. The picture is tricky because of its uneven lighting. With the sun's elevation angle at only 6 degrees, night is falling on the left side of the image while it is still broad daylight on the right side. This gradient of sunlight is the key to the illusion.

  8. The opium poppy as a symbol of sleep in Bertel Thorvaldsen's relief of 1815.

    PubMed

    Tekiner, Halil; Kosar, Muberra

    2016-03-01

    Danish sculptor Bertel Thorvaldsen (1770-1844) is one of the most remarkable representatives of Neoclassicist sculptural art in Europe, which was largely inspired by the classical art and culture of Greek and Roman antiquity. A pair of marble reliefs, Night and Day, exhibited in the Thorvaldsen Museum (Copenhagen), marks the culmination of Thorvaldsen's relief art and is of particular interest to the history of sleep medicine. In the first relief, Night, an angel with her neck bent and eyes closed has two babies in her embrace and seems to be floating down in grief, with an owl hovering behind her. Her hair is also twined with opium poppies, the symbol of sleep and death in antiquity. Our findings suggest that this relief not only indicates a mythological association between the opium poppy and sleep but also has a strong connotation with the poppy's medicinal use for inducing sleep throughout the centuries. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Alginate/cashew gum floating bead as a matrix for larvicide release.

    PubMed

    Paula, Haroldo C B; de Oliveira, Erick F; Abreu, Flávia O M S; de Paula, Regina C M

    2012-08-01

    A polymeric floating system composed of Alginate (ALG) and Cashew gum (CG), loaded with an essential oil (Lippia sidoides-Ls) was prepared by ionotropic gelation, characterized regarding its physical-chemistry properties and evaluated on its potential as a controlled release system. The influence of process parameters on the buoyancy, loading, swelling and in vitro and in vivo release kinetics, was investigated. Results showed that beads produced with carbonate and Ls at high level contents exhibit good floatability (up to 5 days) and loading capacity (15.2-23.8%). In vitro release data showed a Fickian diffusion profile and in vivo experiments showed that ALG-CG floating system presented a superior and prolonged larvicide effect, in comparison with non-floating ones, presenting larvae mortality values of 85% and 33%, respectively, after 48 h. These results indicate that ALG-CG floating beads loaded with Ls presented enhanced oil entrapment efficiency, excellent floating ability, and suitable larvicide release pattern. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Motion performance and mooring system of a floating offshore wind turbine

    NASA Astrophysics Data System (ADS)

    Zhao, Jing; Zhang, Liang; Wu, Haitao

    2012-09-01

    The development of offshore wind farms was originally carried out in shallow water areas with fixed (seabed mounted) structures. However, countries with limited shallow water areas require innovative floating platforms to deploy wind turbines offshore in order to harness wind energy to generate electricity in deep seas. The performances of motion and mooring system dynamics are vital to designing a cost effective and durable floating platform. This paper describes a numerical model to simulate dynamic behavior of a new semi-submersible type floating offshore wind turbine (FOWT) system. The wind turbine was modeled as a wind block with a certain thrust coefficient, and the hydrodynamics and mooring system dynamics of the platform were calculated by SESAM software. The effect of change in environmental conditions on the dynamic response of the system under wave and wind loading was examined. The results indicate that the semi-submersible concept has excellent performance and SESAM could be an effective tool for floating wind turbine design and analysis.

  11. Resident duty hour modification affects perceptions in medical education, general wellness, and ability to provide patient care.

    PubMed

    Moeller, Andrew; Webber, Jordan; Epstein, Ian

    2016-07-13

    Resident duty hours have recently been under criticism, with concerns for resident and patient well-being. Historically, call shifts have been long, and some residency training programs have now restricted shift lengths. Data and opinions about the effects of such restrictions are conflicting. The Internal Medicine Residency Program at Dalhousie University recently moved from a traditional call structure to a day float/night float system. This study evaluated how this change in duty hours affected resident perceptions in several key domains. Senior residents from an internal medicine training program in Canada responded to an anonymous online survey immediately before and 6 months after the implementation of duty hour reform. The survey contained questions relating to three major domains: resident wellness, ability to deliver quality health care, and medical education experience. Mean pre- and post-intervention scores were compared using the t-test for paired samples. Twenty-three of 27 (85 %) senior residents completed both pre- and post-reform surveys. Residents perceived significant changes in many domains with duty hour reform. These included improved general wellness, less exposure to personal harm, fewer feelings of isolation, less potential for error, improvement in clinical skills expertise, increased work efficiency, more successful teaching, increased proficiency in medical skills, more successful learning, and fewer rotation disruptions. Senior residents in a Canadian internal medicine training program perceived significant benefits in medical education experience, ability to deliver healthcare, and resident wellness after implementation of duty hour reform.

  12. The control of float zone interfaces by the use of selected boundary conditions

    NASA Technical Reports Server (NTRS)

    Foster, L. M.; Mcintosh, J.

    1983-01-01

    The main goal of the float zone crystal growth project of NASA's Materials Processing in Space Program is to thoroughly understand the molten zone/freezing crystal system and all the mechanisms that govern this system. The surface boundary conditions required to give flat float zone solid melt interfaces were studied and computed. The results provide float zone furnace designers with better methods for controlling solid melt interface shapes and for computing thermal profiles and gradients. Documentation and a user's guide were provided for the computer software.

  13. Defining the IEEE-854 floating-point standard in PVS

    NASA Technical Reports Server (NTRS)

    Miner, Paul S.

    1995-01-01

    A significant portion of the ANSI/IEEE-854 Standard for Radix-Independent Floating-Point Arithmetic is defined in PVS (Prototype Verification System). Since IEEE-854 is a generalization of the ANSI/IEEE-754 Standard for Binary Floating-Point Arithmetic, the definition of IEEE-854 in PVS also formally defines much of IEEE-754. This collection of PVS theories provides a basis for machine checked verification of floating-point systems. This formal definition illustrates that formal specification techniques are sufficiently advanced that is is reasonable to consider their use in the development of future standards.

  14. Floating Collection in an Academic Library: An Audacious Experiment That Succeeded

    ERIC Educational Resources Information Center

    Coopey, Barbara; Eshbach, Barbara; Notartomas, Trish

    2016-01-01

    Can a floating collection thrive in a large multicampus academic research library? Floating collections have been successful in public libraries for some time, but it is uncommon for academic libraries and unheard of for a large academic library system. This article will discuss the investigation into the feasibility of a floating collection at…

  15. Formulation and in-vitro evaluation of floating bilayer tablet of lisinopril maleate and metoprolol tartrate.

    PubMed

    Ijaz, Hira; Qureshi, Junaid; Danish, Zeeshan; Zaman, Muhammad; Abdel-Daim, Mohamed; Hanif, Muhammad; Waheed, Imran; Mohammad, Imran Shair

    2015-11-01

    The purpose of this study was to introduce the technology for the development of rate-controlled oral drug delivery system to overcome various physiological problems. Several approaches are being used for the purpose of increasing the gastric retentive time, including floating drug delivery system. Gastric floating lisinopril maleate and metoprolol tartrate bilayer tablets were formulated by direct compression method using the sodium starch glycolate, crosscarmellose sodium for IR layer. Eudragit L100, pectin, acacia as sustained release polymers in different ratios for SR metoprolol tartrate layer and sodium bicarbonate, citric acid as gas generating agents for the floating extended release layer. The floating bilayer tablets of lisinopril maleate and metoprolol tartrate were designed to overcome the various problems associated with conventional oral dosage form. Floating tablets were evaluated for floating lag time, drug contents and in-vitro dissolution profile and different kinetic release models were applied. It was clear that the different ratios of polymers affected the drug release and floating time. L2 and M4 showed good drug release profile and floating behavior. The linear regression and model fitting showed that all formulation followed Higuchi model of drug release model except M4 that followed zero order kinetic. From the study it is evident that a promising controlled release by floating bilyer tablets of lisinopril maleate and metoprolol tartrate can be developed successfully.

  16. KSC-06pd2794

    NASA Image and Video Library

    2006-12-10

    KENNEDY SPACE CENTER, FLA. -- Floating in the Atlantic Ocean about 150 miles north east of Cape Canaveral are the right and left solid rocket boosters, which were jettisoned from the Space Shuttle Discovery two and a half minutes into the ascent to orbit on Dec. 9. Though the boosters landed in the ocean miles from each other, overnight wind and ocean currents allowed the left booster, which was floating higher in the water, to migrate to the location of the right booster. The SRB retrieval team monitored the boosters through the night, and confirmed that the boosters did not contact each other. Both boosters were towed back to Hangar AF at the Cape Canaveral Air Force Station, where the refurbishment operations are now underway. Discovery lifted off from KSC's Launch Pad 39B at 8:47 p.m. EST on mission STS-116. For more information about the process of retrieval, go to http://www-pao.ksc.nasa.gov/kscpao/nasafact/pdf/SRBships06.pdf and http://www.nasa.gov/mission_pages/shuttle/behindscenes/recovery_ships.html. This was the second launch attempt for mission STS-116. The first launch attempt on Dec. 7 was postponed due a low cloud ceiling over Kennedy Space Center. This is Discovery's 33rd mission and the first night launch since 2002. The 20th shuttle mission to the International Space Station, STS-116 carries another truss segment, P5. It will serve as a spacer, mated to the P4 truss that was attached in September. After installing the P5, the crew will reconfigure and redistribute the power generated by two pairs of U.S. solar arrays. Landing is expected Dec. 21 at KSC.

  17. In-Situ F2-Region Plasma Density and Temperature Measurements from the International Space Station

    NASA Technical Reports Server (NTRS)

    Coffey, Victoria; Wright, Kenneth; Minow, Joseph

    2008-01-01

    The International Space Station orbit provides an ideal platform for in-situ studies of space weather effects on the mid and low latitude F-2 region ionosphere. The Floating Potential Measurement Unit (FPMU) operating on the ISS since Aug 2006. is a suite of plasma instruments: a Floating Potential Probe (FPP), a Plasma Impedance Probe (PIP), a Wide-sweep langmuir Probe (WLP), and a Narrow-sweep Langmuir Probe (NLP). This instrument package provides a new opportunity lor collaborative multi-instrument studies of the F-region ionosphere during both quiet and disturbed periods. This presentation first describes the operational parameters for each of the FPMU probes and shOWS examples of an intra-instrument validation. We then show comparisons with the plasma density and temperature measurements derived from the TIMED GUVI ultraviolet imager, the Millstone Hill ground based incoherent scatter radar, and DIAS digisondes, Finally we show one of several observations of night-time equatorial density holes demonstrating the capabilities of the probes lor monitoring mid and low latitude plasma processes.

  18. Viewing region maximization of an integral floating display through location adjustment of viewing window.

    PubMed

    Kim, Joowhan; Min, Sung-Wook; Lee, Byoungho

    2007-10-01

    Integral floating display is a recently proposed three-dimensional (3D) display method which provides a dynamic 3D image in the vicinity to an observer. It has a viewing window only through which correct 3D images can be observed. However, the positional difference between the viewing window and the floating image causes limited viewing zone in integral floating system. In this paper, we provide the principle and experimental results of the location adjustment of the viewing window of the integral floating display system by modifying the elemental image region for integral imaging. We explain the characteristics of the viewing window and propose how to move the viewing window to maximize the viewing zone.

  19. Application of a movable active vibration control system on a floating raft

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Mak, Cheuk Ming

    2018-02-01

    This paper presents a theoretical study of an inertial actuator connected to an accelerometer by a local feedback loop for active vibration control on a floating raft. On the criterion of the minimum power transmission from the vibratory machines to the flexible foundation in the floating raft, the best mounting positions for the inertial actuator on the intermediate mass of the floating raft are investigated. Simulation results indicate that the best mounting positions for the inertial actuator vary with frequency. To control time-varying excitations of vibratory machines on a floating raft effectively, an automatic control system based on real-time measurement of a cost function and automatically searching the best mounting position of the inertial actuator is proposed. To the best of our knowledge, it is the first time that an automatic control system is proposed to move an actuator automatically for controlling a time-varying excitation.

  20. Floating Solar Photovoltaics Gaining Ground | State, Local, and Tribal

    Science.gov Websites

    Gaining Ground January 24, 2017 by Alison Holm Floating solar photovoltaic (PV) systems, so-called flotovoltaics (a trademarked term) or floating solar, represent an emerging application in which PV panels are sited on bodies of water. The PV panel technology used for floating solar applications is very similar

  1. A modular optically powered floating high voltage generator.

    PubMed

    Antonini, P; Borsato, E; Carugno, G; Pegoraro, M; Zotto, P

    2013-02-01

    The feasibility of fully floating high voltage (HV) generation was demonstrated producing a prototype of a modular HV system. The primary power source is provided by a high efficiency semiconductor power cell illuminated by a laser system ensuring the floating nature of each module. The HV is then generated by dc-dc conversion and a HV multiplier. The possibility of series connection among modules was verified.

  2. Floating aerial 3D display based on the freeform-mirror and the improved integral imaging system

    NASA Astrophysics Data System (ADS)

    Yu, Xunbo; Sang, Xinzhu; Gao, Xin; Yang, Shenwu; Liu, Boyang; Chen, Duo; Yan, Binbin; Yu, Chongxiu

    2018-09-01

    A floating aerial three-dimensional (3D) display based on the freeform-mirror and the improved integral imaging system is demonstrated. In the traditional integral imaging (II), the distortion originating from lens aberration warps elemental images and degrades the visual effect severely. To correct the distortion of the observed pixels and to improve the image quality, a directional diffuser screen (DDS) is introduced. However, the improved integral imaging system can hardly present realistic images with the large off-screen depth, which limits floating aerial visual experience. To display the 3D image in the free space, the off-axis reflection system with the freeform-mirror is designed. By combining the improved II and the designed freeform optical element, the floating aerial 3D image is presented.

  3. Module assemblage technology for floating systems: in vitro flotation and in vivo gastro-retention.

    PubMed

    Strusi, Orazio Luca; Sonvico, Fabio; Bettini, Ruggero; Santi, Patrizia; Colombo, Gaia; Barata, Pedro; Oliveira, Ana; Santos, Delfim; Colombo, Paolo

    2008-07-14

    The aim of this research was to study, in vitro by resultant-weight measurement and in vivo by gamma-scintigraphy experiments in humans, the floatation behavior of systems obtained by modules assembled in void configuration. The assembled system technology allowed the manufacturing of a system characterized by the presence of an internal void space that provided an apparent density lower than water. The gastro-retention times of floating assembled systems were determined in comparison with non-floating systems having the same mass and composition. In vitro the floatation of the system started immediately after immersion in water and lasted for more than 5 h. The in vivo studies confirmed that the in vitro floating ability of void configuration was maintained also in the human stomach where the system stayed for periods of time ranging from 2.5 to 5.0 h, depending on the food regimen and the sex of the subject. Reiterate eating and drinking further prolonged the stomach residence time.

  4. A Profiling Float System for the North Arabian Sea

    DTIC Science & Technology

    2017-11-29

    purpose of this Defense University Research Instrumentation Program grant was to purchase a set of profiling floats to form an upper ocean observing ...purchase a set of profiling floats to form an upper ocean observing system for the Northern Arabian Sea Circulation - autonomous research (NASCar...resolution numerical simulations. To achieve these goals the DRI will utilize new observational methods that do not rely on a traditional ship-based

  5. A Programmable and Configurable Mixed-Mode FPAA SoC

    DTIC Science & Technology

    2016-03-17

    A Programmable and Configurable Mixed-Mode FPAA SoC Sahil Shah, Sihwan Kim, Farhan Adil, Jennifer Hasler, Suma George, Michelle Collins, Richard...Abstract: The authors present a Floating-Gate based, System-On-Chip large-scale Field- Programmable Analog Array IC that integrates divergent concepts...Floating-Gate, SoC, Command Word Classification This paper presents a Floating-Gate (FG) based, System- On-Chip (SoC) large-scale Field- Programmable

  6. Optimization and characterization of gastroretentive floating drug delivery system using Box-Behnken design.

    PubMed

    Rapolu, Kishore; Sanka, Krishna; Vemula, Praveen Kumar; Aatipamula, Vinaydas; Mohd, Abdul Bari; Diwan, Prakash V

    2013-12-01

    One among many strategies to prolong gastric residence time and improve local effect of the metronidazole in stomach to eradicate Helicobacter pylori in the treatment of peptic ulcer was floating drug delivery system particularly effervescent gastroretentive tablets. The objective of this study was to prepare and evaluate, effervescent floating drug delivery system of a model drug, metronidazole. Effervescent floating drug delivery tablets were prepared by wet granulation method. A three-factor, three levels Box-Behnken design was adopted for the optimization. The selected independent variables were amount of hydroxypropyl methylcellulose K 15M (X1), sodium carboxy methylcellulose (X2) and NaHCO3 (X3). The dependent variables were floating lag time (YFLT), cumulative percentage of metronidazole released at 6th h (Y6) and cumulative percentage of metronidazole released at 12th h (Y12). Physical properties, drug content, in vitro floating lag time, total floating time and drug release behavior were assessed. YFLT range was found to be from 1.02 to 12.07 min. The ranges of other responses, Y6 and Y12 were 25.72 ± 2.85 to 77.14 ± 3.42 % and 65.47 ± 1.25 to 99.65 ± 2.28 %, respectively. Stability studies revealed that no significant change in in vitro floating lag time, total floating time and drug release behavior before and after storage. It can be concluded that a combination of hydroxypropyl methylcellulose K 15M, sodium carboxy methylcellulose and NaHCO3 can be used to increase the gastric residence time of the dosage form to improve local effect of metronidazole.

  7. Float level switch for a nuclear power plant containment vessel

    DOEpatents

    Powell, J.G.

    1993-11-16

    This invention is a float level switch used to sense rise or drop in water level in a containment vessel of a nuclear power plant during a loss of coolant accident. The essential components of the device are a guide tube, a reed switch inside the guide tube, a float containing a magnetic portion that activates a reed switch, and metal-sheathed, ceramic-insulated conductors connecting the reed switch to a monitoring system outside the containment vessel. Special materials and special sealing techniques prevent failure of components and allow the float level switch to be connected to a monitoring system outside the containment vessel. 1 figures.

  8. Float level switch for a nuclear power plant containment vessel

    DOEpatents

    Powell, James G.

    1993-01-01

    This invention is a float level switch used to sense rise or drop in water level in a containment vessel of a nuclear power plant during a loss of coolant accident. The essential components of the device are a guide tube, a reed switch inside the guide tube, a float containing a magnetic portion that activates a reed switch, and metal-sheathed, ceramic-insulated conductors connecting the reed switch to a monitoring system outside the containment vessel. Special materials and special sealing techniques prevent failure of components and allow the float level switch to be connected to a monitoring system outside the containment vessel.

  9. On the dynamic singularities in the control of free-floating space manipulators

    NASA Technical Reports Server (NTRS)

    Papadopoulos, E.; Dubowsky, S.

    1989-01-01

    It is shown that free-floating space manipulator systems have configurations which are dynamically singular. At a dynamically singular position, the manipulator is unable to move its end effector in some direction. This problem appears in any free-floating space manipulator system that permits the vehicle to move in response to manipulator motion without correction from the vehicle's attitude control system. Dynamic singularities are functions of the dynamic properties of the system; their existence and locations cannot be predicted solely from the kinematic structure of the manipulator, unlike the singularities for fixed base manipulators. It is also shown that the location of these dynamic singularities in the workplace is dependent upon the path taken by the manipulator in reaching them. Dynamic singularities must be considered in the control, planning and design of free-floating space manipulator systems. A method for calculating these dynamic singularities is presented, and it is shown that the system parameters can be selected to reduce the effect of dynamic singularities on a system's performance.

  10. Efficient preliminary floating offshore wind turbine design and testing methodologies and application to a concrete spar design

    PubMed Central

    Matha, Denis; Sandner, Frank; Molins, Climent; Campos, Alexis; Cheng, Po Wen

    2015-01-01

    The current key challenge in the floating offshore wind turbine industry and research is on designing economic floating systems that can compete with fixed-bottom offshore turbines in terms of levelized cost of energy. The preliminary platform design, as well as early experimental design assessments, are critical elements in the overall design process. In this contribution, a brief review of current floating offshore wind turbine platform pre-design and scaled testing methodologies is provided, with a focus on their ability to accommodate the coupled dynamic behaviour of floating offshore wind systems. The exemplary design and testing methodology for a monolithic concrete spar platform as performed within the European KIC AFOSP project is presented. Results from the experimental tests compared to numerical simulations are presented and analysed and show very good agreement for relevant basic dynamic platform properties. Extreme and fatigue loads and cost analysis of the AFOSP system confirm the viability of the presented design process. In summary, the exemplary application of the reduced design and testing methodology for AFOSP confirms that it represents a viable procedure during pre-design of floating offshore wind turbine platforms. PMID:25583870

  11. Using Tensor Completion Method to Achieving Better Coverage of Traffic State Estimation from Sparse Floating Car Data

    PubMed Central

    Ran, Bin; Song, Li; Cheng, Yang; Tan, Huachun

    2016-01-01

    Traffic state estimation from the floating car system is a challenging problem. The low penetration rate and random distribution make available floating car samples usually cover part space and time points of the road networks. To obtain a wide range of traffic state from the floating car system, many methods have been proposed to estimate the traffic state for the uncovered links. However, these methods cannot provide traffic state of the entire road networks. In this paper, the traffic state estimation is transformed to solve a missing data imputation problem, and the tensor completion framework is proposed to estimate missing traffic state. A tensor is constructed to model traffic state in which observed entries are directly derived from floating car system and unobserved traffic states are modeled as missing entries of constructed tensor. The constructed traffic state tensor can represent spatial and temporal correlations of traffic data and encode the multi-way properties of traffic state. The advantage of the proposed approach is that it can fully mine and utilize the multi-dimensional inherent correlations of traffic state. We tested the proposed approach on a well calibrated simulation network. Experimental results demonstrated that the proposed approach yield reliable traffic state estimation from very sparse floating car data, particularly when dealing with the floating car penetration rate is below 1%. PMID:27448326

  12. Using Tensor Completion Method to Achieving Better Coverage of Traffic State Estimation from Sparse Floating Car Data.

    PubMed

    Ran, Bin; Song, Li; Zhang, Jian; Cheng, Yang; Tan, Huachun

    2016-01-01

    Traffic state estimation from the floating car system is a challenging problem. The low penetration rate and random distribution make available floating car samples usually cover part space and time points of the road networks. To obtain a wide range of traffic state from the floating car system, many methods have been proposed to estimate the traffic state for the uncovered links. However, these methods cannot provide traffic state of the entire road networks. In this paper, the traffic state estimation is transformed to solve a missing data imputation problem, and the tensor completion framework is proposed to estimate missing traffic state. A tensor is constructed to model traffic state in which observed entries are directly derived from floating car system and unobserved traffic states are modeled as missing entries of constructed tensor. The constructed traffic state tensor can represent spatial and temporal correlations of traffic data and encode the multi-way properties of traffic state. The advantage of the proposed approach is that it can fully mine and utilize the multi-dimensional inherent correlations of traffic state. We tested the proposed approach on a well calibrated simulation network. Experimental results demonstrated that the proposed approach yield reliable traffic state estimation from very sparse floating car data, particularly when dealing with the floating car penetration rate is below 1%.

  13. Multi-input and binary reproducible, high bandwidth floating point adder in a collective network

    DOEpatents

    Chen, Dong; Eisley, Noel A.; Heidelberger, Philip; Steinmacher-Burow, Burkhard

    2016-11-15

    To add floating point numbers in a parallel computing system, a collective logic device receives the floating point numbers from computing nodes. The collective logic devices converts the floating point numbers to integer numbers. The collective logic device adds the integer numbers and generating a summation of the integer numbers. The collective logic device converts the summation to a floating point number. The collective logic device performs the receiving, the converting the floating point numbers, the adding, the generating and the converting the summation in one pass. One pass indicates that the computing nodes send inputs only once to the collective logic device and receive outputs only once from the collective logic device.

  14. Effect of heavy oil on the development of the nervous system of floating and sinking teleost eggs.

    PubMed

    Irie, Kouta; Kawaguchi, Masahumi; Mizuno, Kaori; Song, Jun-Young; Nakayama, Kei; Kitamura, Shin-Ichi; Murakami, Yasunori

    2011-01-01

    Heavy oil (HO) on the sea surface penetrates into fish eggs and prevents the normal morphogenesis. To identify the toxicological effects of HO in the context of the egg types, we performed exposure experiments using floating eggs and sinking eggs. In the course of development, HO-exposed embryos of floating eggs showed abnormal morphology, whereas early larva of the sinking eggs had almost normal morphology. However, the developing peripheral nervous system of sinking eggs showed abnormal projections. These findings suggest that HO exposed fishes have problems in the developing neurons, although they have no morphological malformations. Through these observations, we conclude that HO is strongly toxic to floating eggs in the morphogenesis, and also affect the neuron development in both floating and sinking eggs. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Review on the prevalence of diabetes and risk factors and situation of disease management in floating population in China.

    PubMed

    Han, Kaiyi; Yao, Jingjing; Yin, Xiao; Zhao, Mei; Sun, Qiang

    2017-01-01

    To give a comprehensive and basic understanding of diabetes and its risk factors in floating people in China. We use "(diabetes or type 2 diabetes or chronic disease) and (floating population or employed floating population)" as the key words to search in the China academic literature database (CNKI), Wan Fang database, PubMed and Web of Science for relevant literature and extract the data about the prevalence of diabetes, relevant risk factors and disease management of the floating population in China. Twenty-one literatures are entered into analysis finally, one is English and the rest are Chinese. According to the national survey, the prevalence rate of diabetes in floating population in China was 5. 1% (95%CI, 4.9% - 5.3%), which is lower than that of the general population(11.6%,95%CI, 11.3%-11.8%),and is consistent with the results of the local surveys. The comparison result between the prevalence of floating population and that of local population in each region differs in local surveys. In addition, the prevalence of male floating population is lower than that of the female population. Finally, as the age of the population rises, so does the prevalence of diabetes. As for the risk factors of chronical diseases, the overweight rate in every region is similar but the obesity rate differs in different regions (Ningxia,26.0%;Xiangshan,14.0%), and the obesity rate of the floating population is less than half of that of the general people(4.7%,11.9%). The awareness rate, treatment rate and control rate in the floating patients differ in the regional researches, but they all can't meet the goals set by the local health departments. Compared with the general population, the prevalence of diabetes in the floating population are lower. However, Considering the growing population number and the poor disease management of the floating patients, the potential threat brought by the diabetes in floating population is imponderable. The government should establish the national surveillance system of diabetes for the floating population, strengthen the construction of the primary medical institutions, and optimize the existing funding system.

  16. Formulation and evaluation of non-effervescent floating tablets of losartan potassium.

    PubMed

    Getyala, Anil; Gangadharappa, H V; Prasad, M Sarat Chandra; Reddy, M Praveen Kumar; Kumar, T M Pramod

    2013-10-01

    The aim of the work is to modify the solubility and bioavailability of Losartan potassium, by employing noneffervescent floating drug delivery (tablet dosage forms). Non-effervescent systems are a type of floating drug delivery systems, that have been used to boost the gastric residence and the floatation time in the gastro intestinal tract. The study included formulation of floating tablets using polymers like Chitosan and Karaya gum as matrix forming agents. Accurel(®) MP 1000 was used as floating agent. The tablets were prepared by direct compression technique. FTIR, DSC studies conformed that there was no incompatibility between the polymer and the drug. Tablet preformulation parameters were within the Pharmacopoeial limit. Tablet showed zero lag time, contisnuance of buoyancy for >12 h. The tablet showed good in vitro release. Drug release was through swelling and abided by the gellation mechanism. In vivo X-ray studies depicted that tablets continued to float in the GIT for 12 h. Accelerated stability showed that, tablets were stable for over 6 month. Thus the prepared non-effervescent floating tablet of Losartan potassium can be used for the treatment of hypertension for more than 12 h with single dose administration.

  17. Role of excipients and polymeric advancements in preparation of floating drug delivery systems

    PubMed Central

    Kaushik, Avinash Y; Tiwari, Ajay K; Gaur, Ajay

    2015-01-01

    Since decade or two, the development of floating drug delivery systems becomes a significant and novel tool as having low density than gastric content. There are various advanced polymers including chitosan, eudragit, etc., and excipients such as; pore forming agent, surfactants, etc. All of them are discussed briefly, and results are concluded from various reputed researches. We have discussed all natural and synthetic systems with their effect on the release and other parameters which are essential for the floating formulation development. PMID:25599027

  18. Formulation, release characteristics, and bioavailability study of gastroretentive floating matrix tablet and floating raft system of Mebeverine HCl

    PubMed Central

    El Nabarawi, Mohamed A; Teaima, Mahmoud H; Abd El-Monem, Rehab A; El Nabarawy, Nagla A; Gaber, Dalia A

    2017-01-01

    To prolong the residence time of dosage forms within the gastrointestinal tract until all drug is released at the desired rate is one of the real challenges for oral controlled-release drug delivery systems. This study was designed to develop a controlled-release floating matrix tablet and floating raft system of Mebeverine HCl (MbH) and evaluate different excipients for their floating behavior and in vitro controlled-release profiles. Oral pharmacokinetics of the optimum matrix tablet, raft system formula, and marketed Duspatalin® 200 mg retard as reference were studied in beagle dogs. The optimized tablet formula (FT-10) and raft system formula (FRS-11) were found to float within 34±5 sec and 15±7 sec, respectively, and both remain buoyant over a period of 12 h in simulated gastric fluid. FT-10 (Compritol/HPMC K100M 1:1) showed the slowest drug release among all prepared tablet formulations, releasing about 80.2% of MbH over 8 h. In contrast, FRS-11 (Sodium alginate 3%/HPMC K100M 1%/Precirol 2%) had the greatest retardation, providing sustained release of 82.1% within 8 h. Compared with the marketed MbH product, the Cmax of FT-10 was almost the same, while FRS-11 maximum concentration was higher. The tmax was 3.33, 2.167, and 3.0 h for marketed MbH product, FT-10, and FRS-11, respectively. In addition, the oral bioavailability experiment showed that the relative bioavailability of the MbH was 104.76 and 116.01% after oral administration of FT-10 and FRS-11, respectively, compared to marketed product. These results demonstrated that both controlled-released floating matrix tablet and raft system would be promising gastroretentive delivery systems for prolonging drug action. PMID:28435220

  19. Formulation, release characteristics, and bioavailability study of gastroretentive floating matrix tablet and floating raft system of Mebeverine HCl.

    PubMed

    El Nabarawi, Mohamed A; Teaima, Mahmoud H; Abd El-Monem, Rehab A; El Nabarawy, Nagla A; Gaber, Dalia A

    2017-01-01

    To prolong the residence time of dosage forms within the gastrointestinal tract until all drug is released at the desired rate is one of the real challenges for oral controlled-release drug delivery systems. This study was designed to develop a controlled-release floating matrix tablet and floating raft system of Mebeverine HCl (MbH) and evaluate different excipients for their floating behavior and in vitro controlled-release profiles. Oral pharmacokinetics of the optimum matrix tablet, raft system formula, and marketed Duspatalin ® 200 mg retard as reference were studied in beagle dogs. The optimized tablet formula (FT-10) and raft system formula (FRS-11) were found to float within 34±5 sec and 15±7 sec, respectively, and both remain buoyant over a period of 12 h in simulated gastric fluid. FT-10 (Compritol/HPMC K100M 1:1) showed the slowest drug release among all prepared tablet formulations, releasing about 80.2% of MbH over 8 h. In contrast, FRS-11 (Sodium alginate 3%/HPMC K100M 1%/Precirol 2%) had the greatest retardation, providing sustained release of 82.1% within 8 h. Compared with the marketed MbH product, the C max of FT-10 was almost the same, while FRS-11 maximum concentration was higher. The t max was 3.33, 2.167, and 3.0 h for marketed MbH product, FT-10, and FRS-11, respectively. In addition, the oral bioavailability experiment showed that the relative bioavailability of the MbH was 104.76 and 116.01% after oral administration of FT-10 and FRS-11, respectively, compared to marketed product. These results demonstrated that both controlled-released floating matrix tablet and raft system would be promising gastroretentive delivery systems for prolonging drug action.

  20. Catamaran or semi-submersible for floating platform - selection of a better design

    NASA Astrophysics Data System (ADS)

    Qasim, Idrees; Gao, Liangtian; Peng, Duojin; Liu, Bo

    2018-02-01

    With nonstop advancement in marine engineering, more and more new structures are being designed and explored for tidal current energy. There are three different kinds of support structures for tidal current power station mostly in use, which are sea-bed mounted/gravity based system, pile mounted system and floating moored platform. Comparing all of them, the floating mooring system is most suitable for deep water systems and the application of this arrangement is widely usable. In this paper, a semi-submersible and a catamaran as floating platforms for tidal current power stations are studied are compared on the basis of its economics, efficiency of turbine and stability of the station. Based on basic ship theory and using software MAXSURF, the stability of Catamaran tidal current power station is also calculated. It is found that the catamaran design is optimal choice.

  1. The land use potential of flood-prone rice fields using floating rice system in Bojonegoro regency in East Java

    NASA Astrophysics Data System (ADS)

    Irianto, H.; Mujiyo; Riptanti, E. W.; Qonita, A.

    2018-03-01

    Bojonegoro regency occupies the largest flood-prone rice fields of about 14,198 hectares, in East Java province. Floods commonly occur due to Bengawan Solo river over-burst, particularly in rainy season. The fields are potential for cultivating rice, but floods lasting for months causing these areas to be unproductive. The objective of this article is to examine the potential land use of flood prone rice fields in Bojonegoro regency using floating rice system as an effort to maintain productivity in rainy season. The method of this study is referential study about the rice production using floating cultivation system in other regions, which are later compared with the physical condition of the fields in Bojonegoro. The results of analysis show that rice cultivation using floating system can maintain rice production in flood prone areas during rainy season. The potential production of rice is 5-6 tons/ha. However, technical problems for cultivating rice cannot be ignored since farmers are not familiar with cultivating flooded fields. This article also explains alternatives of floating rice cultivation technique, which can be implemented effectively and efficiently. Pioneer work of developing floating rice in Bojonegoro that has been done by the Team of Faculty of Agriculture of UNS, Surakarta, is expected to serve as a medium for accelerating the adoption of cultivation technology innovation to farmers.

  2. Multi-input and binary reproducible, high bandwidth floating point adder in a collective network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Dong; Eisley, Noel A; Heidelberger, Philip

    To add floating point numbers in a parallel computing system, a collective logic device receives the floating point numbers from computing nodes. The collective logic devices converts the floating point numbers to integer numbers. The collective logic device adds the integer numbers and generating a summation of the integer numbers. The collective logic device converts the summation to a floating point number. The collective logic device performs the receiving, the converting the floating point numbers, the adding, the generating and the converting the summation in one pass. One pass indicates that the computing nodes send inputs only once to themore » collective logic device and receive outputs only once from the collective logic device.« less

  3. Preformulation studies and optimization of sodium alginate based floating drug delivery system for eradication of Helicobacter pylori.

    PubMed

    Diós, Péter; Nagy, Sándor; Pál, Szilárd; Pernecker, Tivadar; Kocsis, Béla; Budán, Ferenc; Horváth, Ildikó; Szigeti, Krisztián; Bölcskei, Kata; Máthé, Domokos; Dévay, Attila

    2015-10-01

    The aim of this study was to design a local, floating, mucoadhesive drug delivery system containing metronidazole for Helicobacter pylori eradication. Face-centered central composite design (with three factors, in three levels) was used for evaluation and optimization of in vitro floating and dissolution studies. Sodium alginate (X1), low substituted hydroxypropyl cellulose (L-HPC B1, X2) and sodium bicarbonate (X3) concentrations were the independent variables in the development of effervescent floating tablets. All tablets showed acceptable physicochemical properties. Statistical analysis revealed that tablets with 5.00% sodium alginate, 38.63% L-HPC B1 and 8.45% sodium bicarbonate content showed promising in vitro floating and dissolution properties for further examinations. Optimized floating tablets expressed remarkable floating force. Their in vitro dissolution studies were compared with two commercially available non-floating metronidazole products and then microbiologically detected dissolution, ex vivo detachment force, rheological mucoadhesion studies and compatibility studies were carried out. Remarkable similarity (f1, f2) between in vitro spectrophotometrically and microbiologically detected dissolutions was found. Studies revealed significant ex vivo mucoadhesion of optimized tablets, which was considerably increased by L-HPC. In vivo X-ray CT studies of optimized tablets showed 8h gastroretention in rats represented by an animation prepared by special CT technique. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Floating-point system quantization errors in digital control systems

    NASA Technical Reports Server (NTRS)

    Phillips, C. L.; Vallely, D. P.

    1978-01-01

    This paper considers digital controllers (filters) operating in floating-point arithmetic in either open-loop or closed-loop systems. A quantization error analysis technique is developed, and is implemented by a digital computer program that is based on a digital simulation of the system. The program can be integrated into existing digital simulations of a system.

  5. Floating gastroretentive drug delivery systems: Comparison of experimental and simulated dissolution profiles and floatation behavior.

    PubMed

    Eberle, Veronika A; Schoelkopf, Joachim; Gane, Patrick A C; Alles, Rainer; Huwyler, Jörg; Puchkov, Maxim

    2014-07-16

    Gastroretentive drug delivery systems (GRDDS) play an important role in the delivery of drug substances to the upper part of the gastrointestinal tract; they offer a possibility to overcome the limited gastric residence time of conventional dosage forms. The aim of the study was to understand drug-release and floatation mechanisms of a floating GRDDS based on functionalized calcium carbonate (FCC). The inherently low apparent density of the excipient (approx. 0.6 g/cm(3)) enabled a mechanism of floatation. The higher specific surface of FCC (approx. 70 m(2)) allowed sufficient hardness of resulting compacts. The floating mechanism of GRDDS was simulated in silico under simulated acidic and neutral conditions, and the results were compared to those obtained in vitro. United States Pharmacopeia (USP) dissolution methods are of limited usefulness for evaluating floating behavior and drug release of floating dosage forms. Therefore, we developed a custom-built stomach model to simultaneously analyze floating characteristics and drug release. In silico dissolution and floatation profiles of the FCC-based tablet were simulated using a three-dimensional cellular automata-based model. In simulated gastric fluid, the FCC-based tablets showed instant floatation. The compacts stayed afloat during the measurement in 0.1 N HCl and eroded completely while releasing the model drug substance. When water was used as dissolution medium, the tablets had no floating lag time and sank down during the measurement, resulting in a change of release kinetics. Floating dosage forms based on FCC appear promising. It was possible to manufacture floating tablets featuring a density of less than unity and sufficient hardness for further processing. In silico dissolution simulation offered a possibility to understand floating behavior and drug-release mechanism. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Methane and carbon dioxide fluxes over a lake: comparison between eddy covariance, floating chambers and boundary layer method

    NASA Astrophysics Data System (ADS)

    Erkkilä, Kukka-Maaria; Ojala, Anne; Bastviken, David; Biermann, Tobias; Heiskanen, Jouni J.; Lindroth, Anders; Peltola, Olli; Rantakari, Miitta; Vesala, Timo; Mammarella, Ivan

    2018-01-01

    Freshwaters bring a notable contribution to the global carbon budget by emitting both carbon dioxide (CO2) and methane (CH4) to the atmosphere. Global estimates of freshwater emissions traditionally use a wind-speed-based gas transfer velocity, kCC (introduced by Cole and Caraco, 1998), for calculating diffusive flux with the boundary layer method (BLM). We compared CH4 and CO2 fluxes from BLM with kCC and two other gas transfer velocities (kTE and kHE), which include the effects of water-side cooling to the gas transfer besides shear-induced turbulence, with simultaneous eddy covariance (EC) and floating chamber (FC) fluxes during a 16-day measurement campaign in September 2014 at Lake Kuivajärvi in Finland. The measurements included both lake stratification and water column mixing periods. Results show that BLM fluxes were mainly lower than EC, with the more recent model kTE giving the best fit with EC fluxes, whereas FC measurements resulted in higher fluxes than simultaneous EC measurements. We highly recommend using up-to-date gas transfer models, instead of kCC, for better flux estimates. BLM CO2 flux measurements had clear differences between daytime and night-time fluxes with all gas transfer models during both stratified and mixing periods, whereas EC measurements did not show a diurnal behaviour in CO2 flux. CH4 flux had higher values in daytime than night-time during lake mixing period according to EC measurements, with highest fluxes detected just before sunset. In addition, we found clear differences in daytime and night-time concentration difference between the air and surface water for both CH4 and CO2. This might lead to biased flux estimates, if only daytime values are used in BLM upscaling and flux measurements in general. FC measurements did not detect spatial variation in either CH4 or CO2 flux over Lake Kuivajärvi. EC measurements, on the other hand, did not show any spatial variation in CH4 fluxes but did show a clear difference between CO2 fluxes from shallower and deeper areas. We highlight that while all flux measurement methods have their pros and cons, it is important to carefully think about the chosen method and measurement interval, as well as their effects on the resulting flux.

  7. New insights on poly(vinyl acetate)-based coated floating tablets: characterisation of hydration and CO2 generation by benchtop MRI and its relation to drug release and floating strength.

    PubMed

    Strübing, Sandra; Abboud, Tâmara; Contri, Renata Vidor; Metz, Hendrik; Mäder, Karsten

    2008-06-01

    The purpose of this study was to investigate the mechanism of floating and drug release behaviour of poly(vinyl acetate)-based floating tablets with membrane controlled drug delivery. Propranolol HCl containing tablets with Kollidon SR as an excipient for direct compression and different Kollicoat SR 30 D/Kollicoat IR coats varying from 10 to 20mg polymer/cm2 were investigated regarding drug release in 0.1N HCl. Furthermore, the onset of floating, the floating duration and the floating strength of the device were determined. In addition, benchtop MRI studies of selected samples were performed. Coated tablets with 10mg polymer/cm2 SR/IR, 8.5:1.5 coat exhibited the shortest lag times prior to drug release and floating onset, the fastest increase in and highest maximum values of floating strength. The drug release was delayed efficiently within a time interval of 24 h by showing linear drug release characteristics. Poly(vinyl acetate) proved to be an appropriate excipient to ensure safe and reliable drug release. Floating strength measurements offered the possibility to quantify the floating ability of the developed systems and thus to compare different formulations more efficiently. Benchtop MRI studies allowed a deeper insight into drug release and floating mechanisms noninvasively and continuously.

  8. Sleep interruption associated with house staff work schedules alters circadian gene expression.

    PubMed

    Fang, Ming Zhu; Ohman-Strickland, Pamela; Kelly-McNeil, Kathie; Kipen, Howard; Crabtree, Benjamin F; Lew, Jenny Pan; Zarbl, Helmut

    2015-11-01

    Epidemiological studies indicate that disruption of circadian rhythm by shift work increases the risk of breast and prostate cancer. Our studies demonstrated that carcinogens disrupt the circadian expression of circadian genes (CGs) and circadian-controlled genes (CCGs) during the early stages of rat mammary carcinogenesis. A chemopreventive regimen of methylselenocysteine (MSC) restored the circadian expression of CGs and CCGs, including PERIOD 2 (PER2) and estrogen receptor β (ERS2), to normal. The present study evaluated whether changes in CG and CCG expression in whole blood can serve as indicators of circadian disruption in shift workers. Fifteen shift workers were recruited to a crossover study. Blood samples were drawn before (6 PM) and after (8 AM) completing a night shift after at least seven days on floating night-shift rotation, and before (8 AM), during (1 PM), and after (6 PM) completing seven days on day shift. The plasma melatonin level and messenger RNA (mRNA) expression of PER2, nuclear receptor subfamily 1, group d, member 1 (NR1D1), and ERS2 were measured, and the changes in levels of melatonin and gene expression were evaluated with statistical analyses. The mRNA expression of PER2 was affected by shift (p = 0.0079); the levels were higher in the evening for the night shift, but higher in the morning for the day shift. Increased PER2 expression (p = 0.034) was observed in the evening on the night versus day shifts. The melatonin level was higher in the morning for both day shifts (p = 0.013) and night shifts (p <0.0001). Changes in the level of PER2 gene expression can serve as a biomarker of disrupted circadian rhythm in blood cells. Therefore, they can be a useful intermediate indicator of efficacy in future MSC-mediated chemoprevention studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Float Zone Workshop

    NASA Technical Reports Server (NTRS)

    Naumann, R. J.

    1980-01-01

    A summary of the Analytical Float Zone Experiment System (AFZES) concept is presented. The types of experiments considered for such a facility are discussed. Reports from various industrial producers and users of float zone material are presented. Special emphasis is placed on state-of-the-art developments in low gravity manufacturing and their applications to space processing.

  10. Sensor Buoy System for Monitoring Renewable Marine Energy Resources.

    PubMed

    García, Emilio; Quiles, Eduardo; Correcher, Antonio; Morant, Francisco

    2018-03-22

    In this paper we present a multi-sensor floating system designed to monitor marine energy parameters, in order to sample wind, wave, and marine current energy resources. For this purpose, a set of dedicated sensors to measure the height and period of the waves, wind, and marine current intensity and direction have been selected and installed in the system. The floating device incorporates wind and marine current turbines for renewable energy self-consumption and to carry out complementary studies on the stability of such a system. The feasibility, safety, sensor communications, and buoy stability of the floating device have been successfully checked in real operating conditions.

  11. Sensor Buoy System for Monitoring Renewable Marine Energy Resources

    PubMed Central

    García, Emilio; Morant, Francisco

    2018-01-01

    In this paper we present a multi-sensor floating system designed to monitor marine energy parameters, in order to sample wind, wave, and marine current energy resources. For this purpose, a set of dedicated sensors to measure the height and period of the waves, wind, and marine current intensity and direction have been selected and installed in the system. The floating device incorporates wind and marine current turbines for renewable energy self-consumption and to carry out complementary studies on the stability of such a system. The feasibility, safety, sensor communications, and buoy stability of the floating device have been successfully checked in real operating conditions. PMID:29565823

  12. Method of manufacturing large dish reflectors for a solar concentrator apparatus

    DOEpatents

    Angel, Roger P [Tucson, AZ; Olbert, Blain H [Tucson, AZ

    2011-12-27

    A method of manufacturing monolithic glass reflectors for concentrating sunlight in a solar energy system is disclosed. The method of manufacturing allows large monolithic glass reflectors to be made from float glass in order to realize significant cost savings on the total system cost for a solar energy system. The method of manufacture includes steps of heating a sheet of float glass positioned over a concave mold until the sheet of glass sags and stretches to conform to the shape of the mold. The edges of the dish-shaped glass are rolled for structural stiffening around the periphery. The dish-shaped glass is then silvered to create a dish-shaped mirror that reflects solar radiation to a focus. The surface of the mold that contacts the float glass preferably has a grooved surface profile comprising a plurality of cusps and concave valleys. This grooved profile minimizes the contact area and marring of the specular glass surface, reduces parasitic heat transfer into the mold and increases mold lifetime. The disclosed method of manufacture is capable of high production rates sufficiently fast to accommodate the output of a conventional float glass production line so that monolithic glass reflectors can be produced as quickly as a float glass production can make sheets of float glass to be used in the process.

  13. Efficient preliminary floating offshore wind turbine design and testing methodologies and application to a concrete spar design.

    PubMed

    Matha, Denis; Sandner, Frank; Molins, Climent; Campos, Alexis; Cheng, Po Wen

    2015-02-28

    The current key challenge in the floating offshore wind turbine industry and research is on designing economic floating systems that can compete with fixed-bottom offshore turbines in terms of levelized cost of energy. The preliminary platform design, as well as early experimental design assessments, are critical elements in the overall design process. In this contribution, a brief review of current floating offshore wind turbine platform pre-design and scaled testing methodologies is provided, with a focus on their ability to accommodate the coupled dynamic behaviour of floating offshore wind systems. The exemplary design and testing methodology for a monolithic concrete spar platform as performed within the European KIC AFOSP project is presented. Results from the experimental tests compared to numerical simulations are presented and analysed and show very good agreement for relevant basic dynamic platform properties. Extreme and fatigue loads and cost analysis of the AFOSP system confirm the viability of the presented design process. In summary, the exemplary application of the reduced design and testing methodology for AFOSP confirms that it represents a viable procedure during pre-design of floating offshore wind turbine platforms. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  14. Formulation and evaluation of different floating tablets containing metronidazole to target stomach.

    PubMed

    Loh, Zhiao C; Elkordy, Amal A

    2015-01-01

    The purpose of this study is to formulate and develop tablets dosage form containing Metronidazole which has swelling and floating properties as a gastroretentive controlled-release drug delivery system to improve drug bioavailability. Fifteen different formulations of effervescence-forming floating systems were designed using HPMC K15M, xanthan gum, co-povidone, Eudragit® RL PO, pluronic® F-127 and/or polypropylene foam powder as swelling agents and sodium bicarbonate with/ without citric acid as gas-forming agents at different compositions. Six out of these 15 formulations which have satisfactory tablet floating behaviour were further studied with the incorporation of Metronidazole. The tablets were evaluated based on tablet physicochemical properties, floating behaviour, swelling ability and drug dissolution studies which were carried out using 0.1M HCl at 37°C for 8 hours. Furthermore, evaluation of the powder mixtures using Fourier transform infrared (FT-IR) spectroscopy, differential scanning calorimetry (DSC) and scanning electron microscope (SEM) were investigated. Most of the tablets show good physicochemical properties except for F11 which contains pluronic® F-127 as its release-retarding matrix-forming polymer. Other formulations show high swelling capacity, ability to float for at least 8 hours in vitro and have sustained drug release characteristics. Data obtained indicated that F3 which contains HPMC (12.5%w/w), xanthan gum (25%w/w), co-povidone (12.5%w/w) and sodium bicarbonate (31.7%w/w) is a suitable formulation with short floating lag time, good floating behaviour and sustained drug release for at least 8 hours in vitro with a zero order kinetic. Combinations of HPMC K15M and xanthan gum as swelling agents show synergistic effect in retarding drug release and are suitable in providing the most sustained drug release system.

  15. A Self-Powered Fast-Sampling Profiling Float in support of a Mesoscale Ocean Observing System in the Western North Pacific

    NASA Astrophysics Data System (ADS)

    Valdez, T.; Chao, Y.; Davis, R. E.; Jones, J.

    2012-12-01

    This talk will describe a new self-powered profiling float that can perform fast sampling over the upper ocean for long durations in support of a mesoscale ocean observing system in the Western North Pacific. The current state-of-the-art profiling floats can provide several hundreds profiles for the upper ocean every ten days. To quantify the role of the upper ocean in modulating the development of Typhoons requires at least an order of magnitude reduction for the sampling interval. With today's profiling float and battery technology, a fast sampling of one day or even a few hours will reduce the typical lifetime of profiling floats from years to months. Interactions between the ocean and typhoons often involves mesoscale eddies and fronts, which require a dense array of floats to reveal the 3-dimensional structure. To measure the mesoscale ocean over a large area like the Western North Pacific therefore requires a new technology that enables fast sampling and long duration at the same time. Harvesting the ocean renewable energy associated with the vertical temperature differentials has the potential to power profiling floats with fast sampling over long durations. Results from the development and deployment of a prototype self-powered profiling float (known as SOLO-TREC) will be presented. With eight hours sampling in the upper 500 meters, the upper ocean temperature and salinity reveal pronounced high frequency variations. Plans to use the SOLO-TREC technology in support of a dense array of fast sampling profiling floats in the Western North Pacific will be discussed.

  16. Structure and Fabrication of a Microscale Flow-Rate/Skin Friction Sensor

    NASA Technical Reports Server (NTRS)

    Chandrasekharan, Vijay (Inventor); Sells, Jeremy (Inventor); Sheplak, Mark (Inventor); Arnold, David P. (Inventor)

    2014-01-01

    A floating element shear sensor and method for fabricating the same are provided. According to an embodiment, a microelectromechanical systems (MEMS)-based capacitive floating element shear stress sensor is provided that can achieve time-resolved turbulence measurement. In one embodiment, a differential capacitive transduction scheme is used for shear stress measurement. The floating element structure for the differential capacitive transduction scheme incorporates inter digitated comb fingers forming differential capacitors, which provide electrical output proportional to the floating element deflection.

  17. Floating point arithmetic in future supercomputers

    NASA Technical Reports Server (NTRS)

    Bailey, David H.; Barton, John T.; Simon, Horst D.; Fouts, Martin J.

    1989-01-01

    Considerations in the floating-point design of a supercomputer are discussed. Particular attention is given to word size, hardware support for extended precision, format, and accuracy characteristics. These issues are discussed from the perspective of the Numerical Aerodynamic Simulation Systems Division at NASA Ames. The features believed to be most important for a future supercomputer floating-point design include: (1) a 64-bit IEEE floating-point format with 11 exponent bits, 52 mantissa bits, and one sign bit and (2) hardware support for reasonably fast double-precision arithmetic.

  18. Floating point only SIMD instruction set architecture including compare, select, Boolean, and alignment operations

    DOEpatents

    Gschwind, Michael K [Chappaqua, NY

    2011-03-01

    Mechanisms for implementing a floating point only single instruction multiple data instruction set architecture are provided. A processor is provided that comprises an issue unit, an execution unit coupled to the issue unit, and a vector register file coupled to the execution unit. The execution unit has logic that implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA). The floating point vector registers of the vector register file store both scalar and floating point values as vectors having a plurality of vector elements. The processor may be part of a data processing system.

  19. Medical education and the ACGME duty hour requirements: assessing the effect of a day float system on educational activities.

    PubMed

    Roey, Steve

    2006-01-01

    In July 2003, the Accreditation Council for Graduate Medical Education (ACGME) instituted new resident work hour mandates, which are being shown to improve resident well-being and patient safety. However, there are limited data on the impact these new mandates may have on educational activities. To assess the impact on educational activities of a day float system created to meet ACGME work hour mandates. The inpatient ward coverage was changed by adding a day float team responsible for new patient admissions in the morning, with the on-call teams starting later and being responsible for new patient admissions thereafter. I surveyed the residents to assess the impact of this new system on educational activities-resident autonomy, attending teaching, conference attendance, resident teaching, self-directed learning, and ability to complete patient care responsibilities. There was no adverse effect of the day float system on educational activities. House staff reported increased autonomy, enhanced teaching from attending physicians, and improved ability to complete patient care responsibilities. Additionally, house staff demonstrated improved compliance with the ACGME mandates. The implementation of a novel day float system for the inpatient medicine ward service improved compliance with ACGME work duty requirements and did not adversely impact educational activities of the residency training program.

  20. A novel automated alternating current biosusceptometry method to characterization of controlled-release magnetic floating tablets of metronidazole.

    PubMed

    Ferrari, Priscileila Colerato; dos Santos Grossklauss, Dany Bruno Borella; Alvarez, Matheus; Paixão, Fabiano Carlos; Andreis, Uilian; Crispim, Alexandre Giordano; de Castro, Ana Dóris; Evangelista, Raul Cesar; de Arruda Miranda, José Ricardo

    2014-08-01

    Alternating Current Biosusceptometry is a magnetically method used to characterize drug delivery systems. This work presents a system composed by an automated ACB sensor to acquire magnetic images of floating tablets. The purpose of this study was to use an automated Alternating Current Biosusceptometry (ACB) to characterize magnetic floating tablets for controlled drug delivery. Floating tablets were prepared with hydroxypropyl methylcellulose (HPMC) as hydrophilic gel material, sodium bicarbonate as gas-generating agent and ferrite as magnetic marker. ACB was used to characterize the floating lag time and the tablet hydration rate, by quantification of the magnetic images to magnetic area. Besides the buoyancy, the floating tablets were evaluated for weight uniformity, hardness, swelling and in vitro drug release. The optimized tablets were prepared with equal amounts of HPMC and ferrite, and began to float within 4 min, maintaining the flotation during more than 24 h. The data of all physical parameters lied within the pharmacopeial limits. Drug release at 24 h was about 40%. The ACB results showed that this study provided a new approach for in vitro investigation of controlled-release dosage forms. Moreover, using automated ACB will also be possible to test these parameters in humans allowing to establish an in vitro.in vivo correlation (IVIVC).

  1. Pharmacokinetics and analgesic effect of ketorolac floating delivery system.

    PubMed

    Radwan, Mahasen A; Abou El Ela, Amal El Sayeh F; Hassan, Maha A; El-Maraghy, Dalia A

    2015-05-01

    The efficacy of ketorolac tromethamine (KT) floating alginate beads as a drug delivery system for better control of KT release was investigated. The formulation with the highest drug loading, entrapment efficiency, swelling, buoyancy, and in vitro release would be selected for further in vivo analgesic effect in the mice and pharmacokinetics study in rats compared to the tablet dosage form. KT floating alginate beads were prepared by extrusion congealing technique. KT in plasma samples was analyzed using a UPLC MS/MS assay. The percentage yield, drug loading and encapsulation efficiency were increased proportionally with the hydroxypropylmethyl cellulose (HPMC) polymer amount in the KT floating beads. A reverse relationship was observed between HPMC amount in the beads and the KT in vitro release rate. F3-floating beads were selected, due to its better in vitro results (continued floating for >8 h) than others. A longer analgesic effect was observed for F3 in fed mice as compared to the tablets. After F3 administration to rats, the Cmax (2.2 ± 0.3 µg/ml) was achieved at ∼2 h and the decline in KT concentration was slower. F3 showed a significant increase in the AUC (1.89 fold) in rats as compared to the tablets. KT was successfully formulated as floating beads with prolonged in vitro release extended to a better in vivo characteristic with higher bioavailability in rats. KT in floating beads shows a superior analgesic effect over tablets, especially in fed mice.

  2. Floating Chip Mounting System Driven by Repulsive Force of Permanent Magnets for Multiple On-Site SPR Immunoassay Measurements

    PubMed Central

    Horiuchi, Tsutomu; Tobita, Tatsuya; Miura, Toru; Iwasaki, Yuzuru; Seyama, Michiko; Inoue, Suzuyo; Takahashi, Jun-ichi; Haga, Tsuneyuki; Tamechika, Emi

    2012-01-01

    We have developed a measurement chip installation/removal mechanism for a surface plasmon resonance (SPR) immunoassay analysis instrument designed for frequent testing, which requires a rapid and easy technique for changing chips. The key components of the mechanism are refractive index matching gel coated on the rear of the SPR chip and a float that presses the chip down. The refractive index matching gel made it possible to optically couple the chip and the prism of the SPR instrument easily via elastic deformation with no air bubbles. The float has an autonomous attitude control function that keeps the chip parallel in relation to the SPR instrument by employing the repulsive force of permanent magnets between the float and a float guide located in the SPR instrument. This function is realized by balancing the upward elastic force of the gel and the downward force of the float, which experiences a leveling force from the float guide. This system makes it possible to start an SPR measurement immediately after chip installation and to remove the chip immediately after the measurement with a simple and easy method that does not require any fine adjustment. Our sensor chip, which we installed using this mounting system, successfully performed an immunoassay measurement on a model antigen (spiked human-IgG) in a model real sample (non-homogenized milk) that included many kinds of interfering foreign substances without any sample pre-treatment. The ease of the chip installation/removal operation and simple measurement procedure are suitable for frequent on-site agricultural, environmental and medical testing. PMID:23202030

  3. Apparatus for removing oil and other floating contaminants from a moving body of water

    DOEpatents

    Strohecker, J.W.

    1973-12-18

    The patent describes a process in which floating contaminants such as oil and solid debris are removed from a moving body of water by employing a skimming system which uses the natural gravitational flow of the water. A boom diagonally positioned across the body of water diverts the floating contaminants over a floating weir and into a retention pond where an underflow weir is used to return contaminant-free water to the moving body of water. The floating weir is ballasted to maintain the contaminant-receiving opening therein slightly below the surface of the water during fluctuations in the water level for skimming the contaminants with minimal water removal.

  4. Floating nut retention system

    NASA Technical Reports Server (NTRS)

    Charles, J. F.; Theakston, H. A. (Inventor)

    1980-01-01

    A floating nut retention system includes a nut with a central aperture. An inner retainer plate has an opening which is fixedly aligned with the nut aperture. An outer retainer member is formed of a base plate having an opening and a surface adjacent to a surface of the inner retainer plate. The outer retainer member includes a securing mechanism for retaining the inner retainer plate adjacent to the outer retainer member. The securing mechanism enables the inner retainer plate to float with respect to the outer retainer number, while simultaneously forming a bearing surface for inner retainer plate.

  5. A modified emulsion gelation technique to improve buoyancy of hydrogel tablets for floating drug delivery systems.

    PubMed

    Yom-Tov, Ortal; Seliktar, Dror; Bianco-Peled, Havazelet

    2015-10-01

    The use of buoyant or floating hydrogel tablets is of particular interest in the sustained release of drugs to the stomach. They have an ability to slow the release rates of drugs by prolonging their absorption window in the upper part of the gastrointestinal (GI) tract. In this study we synthesized bioactive hydrogels that have sustainable release rates for drugs in the stomach based on a hydrogel preparation technique that employs emulsifying surfactants. The emulsion gelation technique, which encapsulates oil droplets within the hydrogels during crosslinking, was used to decrease their specific gravity in aqueous environments, resulting in floating drug release depots. Properties such as swelling, buoyancy, density and drug release were manipulated by changing the polymer concentrations, surfactant percentages and the oil:polymer ratios. The relationship between these properties and the hydrogel's floating lag time was documented. The potential for this material to be used as a floating drug delivery system was demonstrated. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. A simple combined floating and anchored collagen gel for enhancing mechanical strength of culture system.

    PubMed

    Harada, Ichiro; Kim, Sung-Gon; Cho, Chong Su; Kurosawa, Hisashi; Akaike, Toshihiro

    2007-01-01

    In this study, a simple combined method consisting of floating and anchored collagen gel in a ligament or tendon equivalent culture system was used to produce the oriented fibrils in fibroblast-populated collagen matrices (FPCMs) during the remodeling and contraction of the collagen gel. Orientation of the collagen fibrils along single axis occurred over the whole area of the floating section and most of the fibroblasts were elongated and aligned along the oriented collagen fibrils, whereas no significant orientation of fibrils was observed in normally contracted FPCMs by the floating method. Higher elasticity and enhanced mechanical strength were obtained using our simple method compared with normally contracted floating FPCMs. The Young's modulus and the breaking point of the FPCMs were dependent on the initial cell densities. This simple method will be applied as a convenient bioreactor to study cellular processes of the fibroblasts in the tissues with highly oriented fibrils such as ligaments or tendons. (c) 2006 Wiley Periodicals, Inc.

  7. Overnight Hospital Experiences for Medical Students: Results of the 2014 Clerkship Directors in Internal Medicine National Survey.

    PubMed

    Goren, Eric N; Leizman, Debra S; La Rochelle, Jeffrey; Kogan, Jennifer R

    2015-09-01

    Since the 2011 Accreditation Council of Graduate Medical Education (ACGME) work hour rules for residents were implemented, 24-30 h call for interns has been replaced by shift work, including night-float. The impact of these changes on undergraduate medical education experiences in internal medicine has not been described. We aimed to determine the current status of medical students' overnight experiences in Internal Medicine clerkships and sub-internships, and to assess internal medicine educators' perceptions of the importance of overnight work during internal medicine rotations. In May 2014, the Clerkship Directors in Internal Medicine (CDIM) conducted its annual survey. Twenty-eight questions about student participation in overnight work and perceptions of the importance of overnight work (rated on 1-5 Likert scale, 1 = very unimportant and 5 =  ery important) were included. Descriptive statistics were used to summarize responses. Free text results were analyzed qualitatively. The response rate was 78 %. A minority of respondents reported students having any overnight experience during the clerkship (38.7 %) or the sub-internship (40.7 %). Only 5 % of respondents reported having students assigned to night-float rotations outside of clerkships or sub-internships. Respondents agreed that overnight experiences were more important during the sub-internship than the clerkship, 4.0 ± 1.1 vs. 3.2 ± 1.2, p < 0.001. Admitting new patients, following their course and responding to emergencies were rated as important overnight tasks for both clerkship and sub-internship students. Overnight experiences offer students additional educational opportunities. Clerkship directors felt that the overnight experience for the sub-intern in particular was an important chance to practice providing emergency cross coverage and other intern roles. In the era of ACGME duty hours, there is a need to further examine whether there is a role for increased overnight hospital experiences for medical students.

  8. [Purification of eutrophic wastewater by Cyperus alternifolius, Coleus blumei and Jasminum sambac planted in a floating phytoremediation system].

    PubMed

    Liu, Shizhe; Lin, Dongjiao; Tang, Shujun; Luo, Jian

    2004-07-01

    In a greenhouse study, Cyperus alternifolius, Coleus blumei and Jasminum sambac were cultured in a floating phytoremediation system with plantation cups inserted into a polyfoam plate that floated in the upper part of a tank filled with 100 L domestic wastewater. The contents of chemical oxygen demand (CODCr), total P (T-P), total N (T-N), soluble P(S-P), ammonia-nitrogen (NH4+ -N) and nitrate-nitrogen (NO3- -N) in the domestic wastewater were tested during the growth of these three plants. The results showed that Cyperus alternifolius and Coleus blumei could grow well in the floating phytoremediation system, their dry weight being 285.8% and 371.4% of the initial weight of planting, respectively, but Jasminum sambac could not grow well, being 125.0% of the initial weight of planting. The removal rate of TN by these 3 plants was 68.0%, 62.0% and 45.0%, and that of NO3- -N, CODCr and TP was 98.0%, 80.0% and 92.0%, 78.0%, 66.0% and 55.0%, and 90.6%, 90.5% and 88.0% respectively. Cyperus alternifolius and Coleus blumei had good effects on the removal of pollutants in the floating phytoremediation system.

  9. Free-floating carsharing systems: innovations in membership prediction, mode share, and vehicle allocation optimization methodologies.

    DOT National Transportation Integrated Search

    2012-08-01

    "Free-floating carsharing systems are among the newest types of carsharing programs. They allow one-way rentals and have no set homes or docks for the carsharing vehicles; instead, users are permitted to drive the vehicles anywhere within the o...

  10. Temporal trends in gaseous mercury evasion from the Mediterranean seawaters.

    PubMed

    Ferrara, R; Mazzolai, B; Lanzillotta, E; Nucaro, E; Pirrone, N

    2000-10-02

    Mercury evasion from seawaters is considered to be one of the main natural sources of mercury released to the atmosphere. The temporal evolution of this mechanism is related to biotic and abiotic processes that produce mercury in its elemental form and as DGM. The efficiency of these processes depends upon the intensity of the solar radiation, the ambient temperature of the air parcel above the seawater, and the water temperature. In the Mediterranean region, the magnitude of these mechanisms are particularly significant, due to favorable climate conditions and to the presence of large cinnabar deposits that cross the whole region; all these synergic factors yield significant evasional fluxes of mercury from the surface water during most of the annual period. In this work, mercury fluxes were measured by using a floating flux chamber connected to an atomic absorption analyzer. Photosynthetic active radiation (PAR) and UV components of the solar radiation were measured using the same system adopted in the EC 'ELDONet project'. The measurements of the mercury evasional fluxes were carried out at three sites of the northern Tyrrhenian Sea during 1998. Two sites were located at unpolluted and polluted coastal areas, and the third was an offshore site. The evasional flux showed a typical daily trend, highest at midday when the ambient temperature and solar radiation were at the maximum, and lowest, near to zero, during the night. Besides the day-night behavior, a seasonal trend was also observed, with minimum values during the winter period (0.7-2.0 ng/m2 h) and maximum values during the summer (10-13 ng/m2 h).

  11. Development of performance specifications for hybrid modeling of floating wind turbines in wave basin tests

    DOE PAGES

    Hall, Matthew; Goupee, Andrew; Jonkman, Jason

    2017-08-24

    Hybrid modeling—combining physical testing and numerical simulation in real time$-$opens new opportunities in floating wind turbine research. Wave basin testing is an important validation step for floating support structure design, but the conventional approaches that use physical wind above the basin are limited by scaling problems in the aerodynamics. Applying wind turbine loads with an actuation system that is controlled by a simulation responding to the basin test in real time offers a way to avoid scaling problems and reduce cost barriers for floating wind turbine design validation in realistic coupled wind and wave conditions. This paper demonstrates the developmentmore » of performance specifications for a system that couples a wave basin experiment with a wind turbine simulation. Two different points for the hybrid coupling are considered: the tower-base interface and the aero-rotor interface (the boundary between aerodynamics and the rotor structure). Analyzing simulations of three floating wind turbine designs across seven load cases reveals the motion and force requirements of the coupling system. By simulating errors in the hybrid coupling system, the sensitivity of the floating wind turbine response to coupling quality can be quantified. The sensitivity results can then be used to determine tolerances for motion tracking errors, force actuation errors, bandwidth limitations, and latency in the hybrid coupling system. These tolerances can guide the design of hybrid coupling systems to achieve desired levels of accuracy. An example demonstrates how the developed methods can be used to generate performance specifications for a system at 1:50 scale. Results show that sensitivities vary significantly between support structure designs and that coupling at the aero-rotor interface has less stringent requirements than those for coupling at the tower base. As a result, the methods and results presented here can inform design of future hybrid coupling systems and enhance understanding of how test results are affected by hybrid coupling quality.« less

  12. Development of performance specifications for hybrid modeling of floating wind turbines in wave basin tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Matthew; Goupee, Andrew; Jonkman, Jason

    Hybrid modeling—combining physical testing and numerical simulation in real time$-$opens new opportunities in floating wind turbine research. Wave basin testing is an important validation step for floating support structure design, but the conventional approaches that use physical wind above the basin are limited by scaling problems in the aerodynamics. Applying wind turbine loads with an actuation system that is controlled by a simulation responding to the basin test in real time offers a way to avoid scaling problems and reduce cost barriers for floating wind turbine design validation in realistic coupled wind and wave conditions. This paper demonstrates the developmentmore » of performance specifications for a system that couples a wave basin experiment with a wind turbine simulation. Two different points for the hybrid coupling are considered: the tower-base interface and the aero-rotor interface (the boundary between aerodynamics and the rotor structure). Analyzing simulations of three floating wind turbine designs across seven load cases reveals the motion and force requirements of the coupling system. By simulating errors in the hybrid coupling system, the sensitivity of the floating wind turbine response to coupling quality can be quantified. The sensitivity results can then be used to determine tolerances for motion tracking errors, force actuation errors, bandwidth limitations, and latency in the hybrid coupling system. These tolerances can guide the design of hybrid coupling systems to achieve desired levels of accuracy. An example demonstrates how the developed methods can be used to generate performance specifications for a system at 1:50 scale. Results show that sensitivities vary significantly between support structure designs and that coupling at the aero-rotor interface has less stringent requirements than those for coupling at the tower base. As a result, the methods and results presented here can inform design of future hybrid coupling systems and enhance understanding of how test results are affected by hybrid coupling quality.« less

  13. The study of recirculating aquaculture system in pond and its purification effect

    NASA Astrophysics Data System (ADS)

    Qu, Jiangqi; Zhang, Qingjing; Jia, Chengxia; Liu, Pan; Yang, Mu

    2017-05-01

    In this paper, a recirculating aquaculture purification system (RAPS) was designed to solve the problems of aquaculture pollution and shortage of freshwater resource according to the characteristic of northern freshwater ponds of China. The system were arranged in series and composed of high density culture pond, deposit pond, floating and submerged plant pond, ecological floating bed pond and biofilm filtrate pond. At the fish density of 20~30kg/m3 in the high density culture pond, the water quality parameters were monitored seasonally. The results indicated that the removal rate of total nitrogen, total phosphorus, ammonia nitrogen and nitrite nitrogen in the recirculating aquaculture system were 69.59%, 77.89%, 72.54% and 68.68%, respectively. The floating and submerged plant pond and ecological floating bed pond can remove TN and TP obviously, and increase dissolved oxygen and transparency significantly. And the biofilm filtrate pond has good effect of removing ammonium nitrogen and nitrite nitrogen, meanwhile, the microbial communities in the recirculating aquaculture system regulate on the water quality. Therefore, the RAPS show significant effects on water saving and pollution emission reducing.

  14. Effects of pore forming agents on chitosan-graft-poly(N-vinylpyrrolidone) hydrogel properties for use as a matrix for floating drug delivery

    NASA Astrophysics Data System (ADS)

    Budianto, E.; Al-Shidqi, M. F.; Cahyana, A. H.

    2017-07-01

    Eradicating H. pylori-based infection by using conventional oral dosage form of amoxicillin trihydrate finds difficulties to overcome rapid gastric retention time. Encapsulating amoxicillin trihydrate in floating drug delivery system may solve the problem. In this research, the floating drug delivery system of amoxicillin trihydrate encapsulated in floating chitosan-graft-poly(N-vinyl pyrrolidone) hydrogels containing CaCO3 and NaHCO3 as pore forming agents has been successfully prepared. Pore forming agents used was varied with the ratio of 10 to 25% pore forming agents to total mass of the used materials. The hydrogel were characterizedusing FTIR spectrophotometer and stereo microscope. As pore forming agents compositions increased, the porosity (%) and floating properties increased but followed by decrease in drug entrapment efficiency. Most of the floating hydrogels possessed floating ability longer than 180 min and the highest porosity was found in hydrogel containing 25% NaHCO3. Hydrogel containing CaCO3 showed sustained drug release profile than hydrogel containing NaHCO3. However, the optimum formulation was achieved at composition of 10% NaHCO3 with 57% of drug entrapped within the hydrogel and 43% drug released. The results of these studies show that NaHCO3 is an effective pore forming agents for chitosan-graft-poly(N-vinyl pyrrolidone) hydrogel preparation as compare to CaCO3.

  15. Free-floating dual-arm robots for space assembly

    NASA Technical Reports Server (NTRS)

    Agrawal, Sunil Kumar; Chen, M. Y.

    1994-01-01

    Freely moving systems in space conserve linear and angular momentum. As moving systems collide, the velocities get altered due to transfer of momentum. The development of strategies for assembly in a free-floating work environment requires a good understanding of primitives such as self motion of the robot, propulsion of the robot due to onboard thrusters, docking of the robot, retrieval of an object from a collection of objects, and release of an object in an object pool. The analytics of such assemblies involve not only kinematics and rigid body dynamics but also collision and impact dynamics of multibody systems. In an effort to understand such assemblies in zero gravity space environment, we are currently developing at Ohio University a free-floating assembly facility with a dual-arm planar robot equipped with thrusters, a free-floating material table, and a free-floating assembly table. The objective is to pick up workpieces from the material table and combine them into prespecified assemblies. This paper presents analytical models of assembly primitives and strategies for overall assembly. A computer simulation of an assembly is developed using the analytical models. The experiment facility will be used to verify the theoretical predictions.

  16. The Usage of Geographical Information System in the Selection of Floating Cages Location for Aquaculture at Prigi Bay, Trenggalek Regency, East Java

    NASA Astrophysics Data System (ADS)

    Armono, H. D.; Mahaputra, B. G.; Zikra, M.

    2018-03-01

    Floating cages is one of the methods of fish farming (aqua culture) that can be developed at rivers, lakes or seas. To determine a proper location for floating cages, there are some requirements that need to be fulfilled to maintain sustainibility of floating cages. Those requirements are the quality of the environment. This paper will discuss the selection of best location for aquaculture activities using Weighted Overlay method in the Geographical Information System, based on the the concentration of chlorophyll-a, sea surface temperature presented by Aqua MODIS Level 1b satellite images. The satellite data will be associated with the measured field data on March and October 2016. The study take place on Prigi Bay, at Trenggalek Regency, East Java. Based on spatial analysis in the Geographical Information System, the Prigi bay generally suitable for aquaculture activities using floating net cages. The result of Weighted Overlay combinations in both periods showed a mean score of 2.18 of 3 where 8.33 km2 (23.13% of the water area) considered as "very suitable" and 27.67 km2 (76.87% of water area) considered "suitable".

  17. Feasibility of and barriers to continuity of care in US general surgery residencies with an 80-hour duty week.

    PubMed

    Morrissey, Shawna; Dumire, Russell; Bost, James; Gregory, James S

    2011-03-01

    The current level of continuity of care for following up a single patient through preoperative evaluation, surgery, and postoperative care is unknown. A survey of residents was performed, asking for their best guess regarding the number of patients seen for 6 common and 4 uncommon surgeries, and ranking barriers to continuity of care. The length of time to achieve single-patient continuity of care in 5 patients was derived as well as the creation of odds ratios for the barriers. A total of 274 residents (56 programs) completed surveys. Residency length was 7 years for common surgeries and 9 for complex surgeries. The 30-hour work restrictions, inability to attend clinic, and floor/ward duties were the barriers to continuity of care. These data were unaffected by type of program, the presence of a night float system, or residency year. Achieving the level of continuity of care used in this article will require a radical change in the length or structure of general surgery residency programs. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Opportunities for Utilizing the International Space Station for Studies of F2- Region Plasma Science and High Voltage Solar Array Interactions with the Plasma Environment

    NASA Technical Reports Server (NTRS)

    Minow, Joseph I.; Coffey, Victoria; Wright, Kenneth; Craven, Paul; Koontz, Steven

    2010-01-01

    The near circular, 51.6deg inclination orbit of the International Space Station (ISS) is maintained within an altitude range of approximately 300 km to 400 km providing an ideal platform for conducting in-situ studies of space weather effects on the mid and low-latitude F-2 region ionosphere. The Floating Potential Measurement Unit (FPMU) is a suite of instruments installed on the ISS in August 2006 which includes a Floating Potential Probe (FPP), a Plasma Impedance Probe (PIP), a Wide-sweep Langmuir Probe (WLP), and a Narrow-sweep Langmuir Probe (NLP). The primary purpose for deploying the FPMU is to characterize ambient plasma temperatures and densities in which the ISS operates and to obtain measurements of the ISS potential relative to the space plasma environment for use in characterizing and mitigating spacecraft charging hazards to the vehicle and crew. In addition to the engineering goals, data from the FPMU instrument package is available for collaborative multi-satellite and ground based instrument studies of the F-region ionosphere during both quiet and disturbed periods. Finally, the FPMU measurements supported by ISS engineering telemetry data provides a unique opportunity to investigate interactions of the ISS high voltage (160 volt) solar array system with the plasma environment. This presentation will provide examples of FPMU measurements along the ISS orbit including night-time equatorial plasma density depletions sampled near the peak electron density in the F2-region ionosphere, charging phenomenon due to interaction of the ISS solar arrays with the plasma environment, and modification of ISS charging due to visiting vehicles demonstrating the capabilities of the FPMU probes for monitoring mid and low latitude plasma processes as well as vehicle interactions with the plasma environment.

  19. Floating plant dominance as a stable state

    PubMed Central

    Scheffer, Marten; Szabó, Sándor; Gragnani, Alessandra; van Nes, Egbert H.; Rinaldi, Sergio; Kautsky, Nils; Norberg, Jon; Roijackers, Rudi M. M.; Franken, Rob J. M.

    2003-01-01

    Invasion by mats of free-floating plants is among the most important threats to the functioning and biodiversity of freshwater ecosystems ranging from temperate ponds and ditches to tropical lakes. Dark, anoxic conditions under thick floating-plant cover leave little opportunity for animal or plant life, and they can have large negative impacts on fisheries and navigation in tropical lakes. Here, we demonstrate that floating-plant dominance can be a self-stabilizing ecosystem state, which may explain its notorious persistence in many situations. Our results, based on experiments, field data, and models, represent evidence for alternative domains of attraction in ecosystems. An implication of our findings is that nutrient enrichment reduces the resilience of freshwater systems against a shift to floating-plant dominance. On the other hand, our results also suggest that a single drastic harvest of floating plants can induce a permanent shift to an alternative state dominated by rooted, submerged growth forms. PMID:12634429

  20. Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant

    DOEpatents

    Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN

    2006-02-07

    A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.

  1. Vertical viewing angle enhancement for the 360  degree integral-floating display using an anamorphic optic system.

    PubMed

    Erdenebat, Munkh-Uchral; Kwon, Ki-Chul; Yoo, Kwan-Hee; Baasantseren, Ganbat; Park, Jae-Hyeung; Kim, Eun-Soo; Kim, Nam

    2014-04-15

    We propose a 360 degree integral-floating display with an enhanced vertical viewing angle. The system projects two-dimensional elemental image arrays via a high-speed digital micromirror device projector and reconstructs them into 3D perspectives with a lens array. Double floating lenses relate initial 3D perspectives to the center of a vertically curved convex mirror. The anamorphic optic system tailors the initial 3D perspectives horizontally and vertically disperse light rays more widely. By the proposed method, the entire 3D image provides both monocular and binocular depth cues, a full-parallax demonstration with high-angular ray density and an enhanced vertical viewing angle.

  2. Radiation Issues and Applications of Floating Gate Memories

    NASA Technical Reports Server (NTRS)

    Scheick, L. Z.; Nguyen, D. N.

    2000-01-01

    The radiation effects that affect various systems that comprise floating gate memories are presented. The wear-out degradation results of unirradiated flash memories are compared to irradiated flash memories. The procedure analyzes the failure to write and erase caused by wear-out and degradation of internal charge pump circuits. A method is described for characterizing the radiation effects of the floating gate itself. The rate dependence, stopping power dependence, SEU susceptibility and applications of floating gate in radiation environment are presented. The ramifications for dosimetry and cell failure are discussed as well as for the long term use aspects of non-volatile memories.

  3. On the nature of control algorithms for free-floating space manipulators

    NASA Technical Reports Server (NTRS)

    Papadopoulos, Evangelos; Dubowsky, Steven

    1991-01-01

    It is suggested that nearly any control algorithm that can be used for fixed-based manipulators also can be employed in the control of free-floating space manipulator systems, with the additional conditions of estimating or measuring a spacecraft's orientation and of avoiding dynamic singularities. This result is based on the structural similarities between the kinematic and dynamic equations for the same manipulator but with a fixed base. Barycenters are used to formulate the kinematic and dynamic equations of free-floating space manipulators. A control algorithm for a space manipulator system is designed to demonstrate the value of the analysis.

  4. Hydroponic root mats for wastewater treatment-a review.

    PubMed

    Chen, Zhongbing; Cuervo, Diego Paredes; Müller, Jochen A; Wiessner, Arndt; Köser, Heinz; Vymazal, Jan; Kästner, Matthias; Kuschk, Peter

    2016-08-01

    Hydroponic root mats (HRMs) are ecotechnological wastewater treatment systems where aquatic vegetation forms buoyant filters by their dense interwoven roots and rhizomes, sometimes supported by rafts or other floating materials. A preferential hydraulic flow is created in the water zone between the plant root mat and the bottom of the treatment system. When the mat touches the bottom of the water body, such systems can also function as HRM filter; i.e. the hydraulic flow passes directly through the root zone. HRMs have been used for the treatment of various types of polluted water, including domestic wastewater; agricultural effluents; and polluted river, lake, stormwater and groundwater and even acid mine drainage. This article provides an overview on the concept of applying floating HRM and non-floating HRM filters for wastewater treatment. Exemplary performance data are presented, and the advantages and disadvantages of this technology are discussed in comparison to those of ponds, free-floating plant and soil-based constructed wetlands. Finally, suggestions are provided on the preferred scope of application of HRMs.

  5. Aberration improvement of the floating 3D display system based on Tessar array and directional diffuser screen

    NASA Astrophysics Data System (ADS)

    Gao, Xin; Sang, Xinzhu; Yu, Xunbo; Zhang, Wanlu; Yan, Binbin; Yu, Chongxiu

    2018-06-01

    The floating 3D display system based on Tessar array and directional diffuser screen is proposed. The directional diffuser screen can smoothen the gap of lens array and make the 3D image's brightness continuous. The optical structure and aberration characteristics of the floating three-dimensional (3D) display system are analyzed. The simulation and experiment are carried out, which show that the 3D image quality becomes more and more deteriorative with the further distance of the image plane and the increasing viewing angle. To suppress the aberrations, the Tessar array is proposed according to the aberration characteristics of the floating 3D display system. A 3840 × 2160 liquid crystal display panel (LCD) with the size of 23.6 inches, a directional diffuser screen and a Tessar array are used to display the final 3D images. The aberrations are reduced and the definition is improved compared with that of the display with a single-lens array. The display depth of more than 20 cm and the viewing angle of more than 45° can be achieved.

  6. Northern Arabian Sea Circulation - Autonomous Research: Optimal Planning Systems (NASCar-OPS)

    DTIC Science & Technology

    2015-09-30

    vehicles ( gliders , drifters, floats, and/or wave- gliders ) - Provide guidance for persistent optimal sampling, including for long-duration observation...headings and relative operating speeds will be provided to the operational fleets of instruments and vehicles (e.g. gliders , drifters, floats or wave... gliders ). We plan to use models specific to vehicle types (floats, wave- gliders , etc.). We also plan to further parallelize and optimize our codes

  7. Preparation and evaluation of novel metronidazole sustained release and floating matrix tablets.

    PubMed

    Asnaashari, Solmaz; Khoei, Nazaninossadat Seyed; Zarrintan, Mohammad Hosein; Adibkia, Khosro; Javadzadeh, Yousef

    2011-08-01

    In the present study, metronidazole was used for preparing floating dosage forms that are designed to retain in the stomach for a long time and have developed as a drug delivery system for better eradication of Helicobacter Pylori in peptic ulcer diseases. For this means, various formulations were designed using multi-factorial design. HPMC, psyllium and carbopol in different concentrations were used as floating agents, and sodium bicarbonate was added as a gas-forming agent. Hardness, friability, drug loading, floating ability and release profiles as well as kinetics of release were assessed. Formulations containing HPMC as filler showed prolonged lag times for buoyancy. Adding psyllium to these formulations had reduced relative lag times. Overall, selected formulations were able to float immediately and showed buoyancy for at least 8?h. Meanwhile, sustained profiles of drug release were also obtained. Kinetically, among the 10 assessed models, the release pattern of metronidazole from the tablets fitted best to Power law, Weibull and Higuchi models in respect overall to mean percentage error values of 3.8, 4.73 and 5.77, respectively, for calcium carbonate-based tablets and, 2.95, 6.39 and 3.9, respectively, for calcium silicate-based tablets. In general, these systems can float in the gastric condition and control the drug release from the tablets.

  8. Floating tablets for controlled release of ofloxacin via compression coating of hydroxypropyl cellulose combined with effervescent agent.

    PubMed

    Qi, Xiaole; Chen, Haiyan; Rui, Yao; Yang, Fengjiao; Ma, Ning; Wu, Zhenghong

    2015-07-15

    To prolong the residence time of dosage forms within gastrointestinal trace until all drug released at desired rate was one of the real challenges for oral controlled-release drug delivery system. Herein, we developed a fine floating tablet via compression coating of hydrophilic polymer (hydroxypropyl cellulose) combined with effervescent agent (sodium bicarbonate) to achieve simultaneous control of release rate and location of ofloxacin. Sodium alginate was also added in the coating layer to regulate the drug release rate. The effects of the weight ratio of drug and the viscosity of HPC on the release profile were investigated. The optimized formulations were found to immediately float within 30s and remain lastingly buoyant over a period of 12 h in simulated gastric fluid (SGF, pH 1.2) without pepsin, indicating a satisfactory floating and zero-order drug release profile. In addition, the oral bioavailability experiment in New Zealand rabbits showed that, the relative bioavailability of the ofloxacin after administrated of floating tablets was 172.19%, compared to marketed common release tablets TaiLiBiTuo(®). These results demonstrated that those controlled-released floating tables would be a promising gastro-retentive delivery system for drugs acting in stomach. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Capture of free-floating planets by planetary systems

    NASA Astrophysics Data System (ADS)

    Goulinski, Nadav; Ribak, Erez N.

    2018-01-01

    Evidence of exoplanets with orbits that are misaligned with the spin of the host star may suggest that not all bound planets were born in the protoplanetary disc of their current planetary system. Observations have shown that free-floating Jupiter-mass objects can exceed the number of stars in our Galaxy, implying that capture scenarios may not be so rare. To address this issue, we construct a three-dimensional simulation of a three-body scattering between a free-floating planet and a star accompanied by a Jupiter-mass bound planet. We distinguish between three different possible scattering outcomes, where the free-floating planet may get weakly captured after the brief interaction with the binary, remain unbound or 'kick out' the bound planet and replace it. The simulation was performed for different masses of the free-floating planets and stars, as well as different impact parameters, inclination angles and approach velocities. The outcome statistics are used to construct an analytical approximation of the cross-section for capturing a free-floating planet by fitting their dependence on the tested variables. The analytically approximated cross-section is used to predict the capture rate for these kinds of objects, and to estimate that about 1 per cent of all stars are expected to experience a temporary capture of a free-floating planet during their lifetime. Finally, we propose additional physical processes that may increase the capture statistics and whose contribution should be considered in future simulations in order to determine the fate of the temporarily captured planets.

  10. Chemical Oxygen Demand abatement in sewage using Micro-Aeration Enhanced Ecological Floating Bed

    NASA Astrophysics Data System (ADS)

    Shi, Hongle; Zhou, Gaofeng; Liu, Yiqing; Tan, Jiancong; Fu, Yongsheng

    2018-02-01

    The traditional ecological floating bed combined with micro-aeration system and artificial medium was developed for the removal of contaminants and remediation of surface water. This micro-aeration enhanced ecological floating bed (MAEEFB) consisted of aeration unit, microbial processing unit and aquatic plant unit. Batch experiments were conducted in different operating conditions on the removal of chemical oxygen demand (COD) in the sewage using MAEEFB. The removal rate of COD by MAEEFB, enhanced ecological floating bed (EEFB) and traditional ecological floating bed (TEFB) in the same reaction conditions was 59.2%, 56.9% and 30.6%, respectively, indicating that the combination of micro-aeration system and artificial medium could enhance the removal efficiency of COD in TEFB. In MAEEFB, the aeration intensity should be designed reasonablely considering both treatment efficiency and operation cost. Only increasing the specific surface area of the packing cannot effectively improve the purification efficiency of water. Factors like packing material, ability of intercepting organics and complicated extent of microorganisms attaching on the packing should also be considered.

  11. Development and Characterization of Novel Floating-Mucoadhesive Tablets Bearing Venlafaxine Hydrochloride.

    PubMed

    Misra, Raghvendra; Bhardwaj, Peeyush

    2016-01-01

    The present investigation is concerned about the development of floating bioadhesive drug delivery system of venlafaxine hydrochloride which after oral administration exhibits a unique combination of floating and bioadhesion to prolong gastric residence time and increase drug bioavailability within the stomach. The floating bioadhesive tablets were prepared by the wet granulation method using different ratios of hydroxypropyl methyl cellulose (HPMC K4MCR) and Carbopol 934PNF as polymers. Sodium bicarbonate (NaHCO3) and citric acid were used as gas (CO2) generating agents. Tablets were characterized for floating properties, in vitro drug release, detachment force, and swelling index. The concentration of hydroxypropyl methyl cellulose and Carbopol 934PNF significantly affects the in vitro drug release, floating properties, detachment force, and swelling properties of the tablets. The optimized formulation showed the floating lag time 72 ± 2.49 seconds and duration of floating 24.50 ± 0.74 hr. The in vitro release studies and floating behavior were studied in simulated gastric fluid (SGF) at pH 1.2. Different drug release kinetics models were also applied. The in vitro drug release from tablets was sufficiently sustained (more than 18 hr) and the Fickian transports of the drug from the tablets were confirmed. The radiological evidence suggests that the tablets remained buoyant and altered position in the stomach of albino rabbit and mean gastric residence time was prolonged (more than > 6 hr).

  12. Freely Drifting Swallow Float Array: August 1990 NATIVE 1 Experiment (First Deployment)

    DTIC Science & Technology

    1991-02-01

    jump around record 1520, indicating that the apparent increase in float 2’s hydrophone sensitivity occurred only at the lower infra - sonic ...and d) the infrasonic acoustic data. The infrasonic data include the RMS levels of the pressure and the three components of parti- cle velocity for all...active intensity spectra. A description of the Swallow float infrasonic data acquisition system, along with calibration curves, is given in Appendix 1

  13. Selection of floating-point or fixed-point for adaptive noise canceller in somatosensory evoked potential measurement.

    PubMed

    Shen, Chongfei; Liu, Hongtao; Xie, Xb; Luk, Keith Dk; Hu, Yong

    2007-01-01

    Adaptive noise canceller (ANC) has been used to improve signal to noise ratio (SNR) of somsatosensory evoked potential (SEP). In order to efficiently apply the ANC in hardware system, fixed-point algorithm based ANC can achieve fast, cost-efficient construction, and low-power consumption in FPGA design. However, it is still questionable whether the SNR improvement performance by fixed-point algorithm is as good as that by floating-point algorithm. This study is to compare the outputs of ANC by floating-point and fixed-point algorithm ANC when it was applied to SEP signals. The selection of step-size parameter (micro) was found different in fixed-point algorithm from floating-point algorithm. In this simulation study, the outputs of fixed-point ANC showed higher distortion from real SEP signals than that of floating-point ANC. However, the difference would be decreased with increasing micro value. In the optimal selection of micro, fixed-point ANC can get as good results as floating-point algorithm.

  14. A new approach in gastroretentive drug delivery system using cholestyramine.

    PubMed

    Umamaheshwari, R B; Jain, Subheet; Jain, N K

    2003-01-01

    We prepared cellulose acetate butyrate (CAB)-coated cholestyramine microcapsules as a intragastric floating drug delivery system endowed with floating ability due to the carbon dioxide generation when exposed to the gastric fluid. The microcapsules also have a mucoadhesive property. Ion-exchange resin particles can be loaded with bicarbonate followed by acetohydroxamic acid (AHA) and coated with CAB by emulsion solvent evaporation method. The drug concentration was monitored to maintain the floating property and minimum effective concentration. The effect of CAB: drug-resin ratio (2:1, 4:1, 6:1 w/w) on the particle size, floating time, and drug release was determined. Cholestyramine microcapsules were characterized for shape, surface characteristics, and size distribution; cholestyramine/acetohydroxamic acid interactions inside microcapsules were investigated by X-ray diffractometry. The buoyancy time of CAB-coated formulations was better than that of uncoated resin particles. Also, a longer floating time was observed with a higher polymer:drug resin complex ratio (6:1). With increasing coating thickness the particle size was increased but drug release rate was decreased. The drug release rate was higher in simulated gastric fluid (SGF) than in simulated intestinal fluid (SIF). The in vivo mucoadhesion studies were performed with rhodamine-isothiocyanate (RITC) by fluorescent probe method. The amount of CAB-coated cholestyramine microcapsules that remained in the stomach was slightly lower than that of uncoated resin particles. Cholestyramine microcapsules were distributed throughout the stomach and exhibited prolonged gastric residence via mucoadhesion. These results suggest that CAB-coated microcapsules could be a floating as well as a mucoadhesive drug delivery system. Thus, it has promise in the treatment of Helicobacter pylori.

  15. Verification of floating-point software

    NASA Technical Reports Server (NTRS)

    Hoover, Doug N.

    1990-01-01

    Floating point computation presents a number of problems for formal verification. Should one treat the actual details of floating point operations, or accept them as imprecisely defined, or should one ignore round-off error altogether and behave as if floating point operations are perfectly accurate. There is the further problem that a numerical algorithm usually only approximately computes some mathematical function, and we often do not know just how good the approximation is, even in the absence of round-off error. ORA has developed a theory of asymptotic correctness which allows one to verify floating point software with a minimum entanglement in these problems. This theory and its implementation in the Ariel C verification system are described. The theory is illustrated using a simple program which finds a zero of a given function by bisection. This paper is presented in viewgraph form.

  16. Method for preparing homogeneous single crystal ternary III-V alloys

    DOEpatents

    Ciszek, Theodore F.

    1991-01-01

    A method for producing homogeneous, single-crystal III-V ternary alloys of high crystal perfection using a floating crucible system in which the outer crucible holds a ternary alloy of the composition desired to be produced in the crystal and an inner floating crucible having a narrow, melt-passing channel in its bottom wall holds a small quantity of melt of a pseudo-binary liquidus composition that would freeze into the desired crystal composition. The alloy of the floating crucilbe is maintained at a predetermined lower temperature than the alloy of the outer crucible, and a single crystal of the desired homogeneous alloy is pulled out of the floating crucible melt, as melt from the outer crucible flows into a bottom channel of the floating crucible at a rate that corresponds to the rate of growth of the crystal.

  17. 8. CAR FLOAT AND TUG DOCKED AT BRIDGE NO. 11 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. CAR FLOAT AND TUG DOCKED AT BRIDGE NO. 11 FROM BRIDGE NO. 9 APRON. LOOKING SOUTHEAST. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ

  18. 9. LOADED CAR FLOAT AND TUG IN THE PROCESS OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. LOADED CAR FLOAT AND TUG IN THE PROCESS OF DOCKING AT BRIDGE NO. 11. LOOKING EAST. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ

  19. Algorithm XXX : functions to support the IEEE standard for binary floating-point arithmetic.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cody, W. J.; Mathematics and Computer Science

    1993-12-01

    This paper describes C programs for the support functions copysign(x,y), logb(x), scalb(x,n), nextafter(x,y), finite(x), and isnan(x) recommended in the Appendix to the IEEE Standard for Binary Floating-Point Arithmetic. In the case of logb, the modified definition given in the later IEEE Standard for Radix-Independent Floating-Point Arithmetic is followed. These programs should run without modification on most systems conforming to the binary standard.

  20. Development of a floating drug delivery system with superior buoyancy in gastric fluid using hot-melt extrusion coupled with pressurized CO₂.

    PubMed

    Almutairy, B K; Alshetaili, A S; Ashour, E A; Patil, H; Tiwari, R V; Alshehri, S M; Repka, M A

    2016-03-01

    The present study aimed to develop a continuous single-step manufacturing platform to prepare a porous, low-density, and floating multi-particulate system (mini-tablet, 4 mm size). This process involves injecting inert, non-toxic pressurized CO₂gas (P-CO₂) in zone 4 of a 16-mm hot-melt extruder (HME) to continuously generate pores throughout the carrier matrix. Unlike conventional methods for preparing floating drug delivery systems, additional chemical excipients and additives are not needed in this approach to create minute openings on the surface of the matrices. The buoyancy efficiency of the prepared floating system (injection of P-CO₂) in terms of lag time (0 s) significantly improved (P < 0.05), compared to the formulation prepared by adding the excipient sodium bicarbonate (lag time 120 s). The main advantages of this novel manufacturing technique include: (i) no additional chemical excipients need to be incorporated in the formulation, (ii) few manufacturing steps are required, (iii) high buoyancy efficiency is attained, and (iv) the extrudate is free of toxic solvent residues. Floating mini-tablets containing acetaminophen (APAP) as a model drug within the matrix-forming carrier (Eudragit® RL PO) have been successfully processed via this combined technique (P-CO₂/HME). Desired controlled release profile of APAP from the polymer Eudragit® RL PO is attained in the optimized formulation, which remains buoyant on the surface of gastric fluids prior to gastric emptying time (average each 4 h).

  1. A case study of middle size floating airports for shallower and deeper waters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshida, Koichiro; Suzuki, Hideyuki; Nishigaki, Makoto

    1996-12-31

    Demands for large and middle size airports are expanding in Japan with continuous increase of air transportation. However these demands will not be satisfied without effective ocean space utilization. Most of the wide and shallower waters suitable for reclamation have already been reclaimed. Furthermore those shallower waters are generally close to the residential area, and noise and environmental problems will be caused if they were used for airports. Deeper waters, which are relatively distant from the shore, are suitable for airport but reclamation of these waters are extremely difficult. This paper presents a structural planning of an open sea typemore » middle size floating airport to promote local economy and also improve transportation infrastructure of isolated islands. The airports of this plan are a semisubmersible type floating structure with a relatively thin deck, a number of slender columns and large size lower hulls. The floating structure is moored by inclined tension legs to restrain the motion. The diameter of the leg becomes much larger compared with the legs of existing tension leg platforms. Parameters related to the configuration of the floating structure and the mooring system are determined by comparing analyses results with the proper design criteria. Several kinds of static and dynamic computer programs are used in the planning. The proposed structural plan and the mooring system are considered as a typical floating airport appropriate for the open sea.« less

  2. Dim nighttime light impairs cognition and provokes depressive-like responses in a diurnal rodent.

    PubMed

    Fonken, Laura K; Kitsmiller, Emily; Smale, Laura; Nelson, Randy J

    2012-08-01

    Circadian disruption is a common by-product of modern life. Although jet lag and shift work are well-documented challenges to circadian organization, many more subtle environmental changes cause circadian disruption. For example, frequent fluctuations in the timing of the sleep/wake schedule, as well as exposure to nighttime lighting, likely affect the circadian system. Most studies of these effects have focused on nocturnal rodents, which are very different from diurnal species with respect to their patterns of light exposure and the effects that light can have on their activity. Thus, the authors investigated the effect of nighttime light on behavior and the brain of a diurnal rodent, the Nile grass rat. Following 3 weeks of exposure to standard light/dark (LD; 14:10 light [~150 lux] /dark [0 lux]) or dim light at night (dLAN; 14:10 light [~150 lux] /dim [5 lux]), rats underwent behavioral testing, and hippocampal neurons within CA1, CA3, and the dentate gyrus (DG) were examined. Three behavioral effects of dLAN were observed: (1) decreased preference for a sucrose solution, (2) increased latency to float in a forced swim test, and (3) impaired learning and memory in the Barnes maze. Light at night also reduced dendritic length in DG and basilar CA1 dendrites. Dendritic length in the DG positively correlated with sucrose consumption in the sucrose anhedonia task. Nighttime light exposure did not disrupt the pattern of circadian locomotor activity, and all grass rats maintained a diurnal activity pattern. Together, these data suggest that exposure to dLAN can alter affective responses and impair cognition in a diurnal animal.

  3. Analysis of Free-floating Bike Sharing and Insights on System Operations : or Analyzing Mobility Patterns and Imbalance of Free Floating Bike Sharing Systems

    DOT National Transportation Integrated Search

    2018-01-31

    Aritra Pal (ORCID ID 0000-0002-2256-2464) Yu Zhang (ORCID ID 0000-0003-1202-626X) Changhyun Kwon (ORCID ID 0000-0001-8455-6396) Bike Sharing is a sustainable mode of urban mobility, not only for regular commuters but also for casual users and tourist...

  4. Calculating surface ocean pCO2 from biogeochemical Argo floats equipped with pH: An uncertainty analysis

    NASA Astrophysics Data System (ADS)

    Williams, N. L.; Juranek, L. W.; Feely, R. A.; Johnson, K. S.; Sarmiento, J. L.; Talley, L. D.; Dickson, A. G.; Gray, A. R.; Wanninkhof, R.; Russell, J. L.; Riser, S. C.; Takeshita, Y.

    2017-03-01

    More than 74 biogeochemical profiling floats that measure water column pH, oxygen, nitrate, fluorescence, and backscattering at 10 day intervals have been deployed throughout the Southern Ocean. Calculating the surface ocean partial pressure of carbon dioxide (pCO2sw) from float pH has uncertainty contributions from the pH sensor, the alkalinity estimate, and carbonate system equilibrium constants, resulting in a relative standard uncertainty in pCO2sw of 2.7% (or 11 µatm at pCO2sw of 400 µatm). The calculated pCO2sw from several floats spanning a range of oceanographic regimes are compared to existing climatologies. In some locations, such as the subantarctic zone, the float data closely match the climatologies, but in the polar Antarctic zone significantly higher pCO2sw are calculated in the wintertime implying a greater air-sea CO2 efflux estimate. Our results based on four representative floats suggest that despite their uncertainty relative to direct measurements, the float data can be used to improve estimates for air-sea carbon flux, as well as to increase knowledge of spatial, seasonal, and interannual variability in this flux.

  5. Considerations on the effects of tidal regimes in the movement of floating litter in an estuarine environment: Case study of the estuarine system of Santos-São Vicente, Brazil.

    PubMed

    Fernandino, Gerson; Elliff, Carla Isobel; Frutuoso, Gabriela Amado; Silva, Eric Vinícius Nascimento Malaquias da; Gama, Guilherme Santiago; Sousa, João Henrique de Oliveira; Silva, Iracema Reimão

    2016-09-15

    Floating litter in the estuarine system of Santos-São Vicente is common and is part of day-to-day activities of various users of the area. The objective of the present study was to carry out a quali-quantitative evaluation of the occurrence of floating litter, to infer their sources, and to identify environmental factors that are likely to control occurrence and distribution, with particular emphasis on the effects of tidal regimes. Six sampling stations were selected along the aforementioned estuary and visited monthly between July 2010 and January 2012. Floating litter was counted from a fixed sampling station. Plastics prevailed (89.64%) and their main source was domestic activities (55.41%). More litter was found during ebb spring tides, with higher concentrations obeying confluence patterns of the estuary's channels. Results indicated that occurrence can be attributed to the deficiency in basic sewage system in the area and the deliberate disposal into the estuary by the local population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Real object-based 360-degree integral-floating display using multiple depth camera

    NASA Astrophysics Data System (ADS)

    Erdenebat, Munkh-Uchral; Dashdavaa, Erkhembaatar; Kwon, Ki-Chul; Wu, Hui-Ying; Yoo, Kwan-Hee; Kim, Young-Seok; Kim, Nam

    2015-03-01

    A novel 360-degree integral-floating display based on the real object is proposed. The general procedure of the display system is similar with conventional 360-degree integral-floating displays. Unlike previously presented 360-degree displays, the proposed system displays the 3D image generated from the real object in 360-degree viewing zone. In order to display real object in 360-degree viewing zone, multiple depth camera have been utilized to acquire the depth information around the object. Then, the 3D point cloud representations of the real object are reconstructed according to the acquired depth information. By using a special point cloud registration method, the multiple virtual 3D point cloud representations captured by each depth camera are combined as single synthetic 3D point cloud model, and the elemental image arrays are generated for the newly synthesized 3D point cloud model from the given anamorphic optic system's angular step. The theory has been verified experimentally, and it shows that the proposed 360-degree integral-floating display can be an excellent way to display real object in the 360-degree viewing zone.

  7. 16. EAST ELEVATION OF FLOAT HOUSE AND FISH WATER RELEASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. EAST ELEVATION OF FLOAT HOUSE AND FISH WATER RELEASE OUTLET. PART OF ENERGY DISSIPATING BAFFLE PIER SYSTEM IS VISIBLE AT LEFT. - Pit 4 Diversion Dam, Pit River west of State Highway 89, Big Bend, Shasta County, CA

  8. Outpatient safety assessment of an in-home predictive low-glucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia.

    PubMed

    Buckingham, Bruce A; Cameron, Fraser; Calhoun, Peter; Maahs, David M; Wilson, Darrell M; Chase, H Peter; Bequette, B Wayne; Lum, John; Sibayan, Judy; Beck, Roy W; Kollman, Craig

    2013-08-01

    Nocturnal hypoglycemia is a common problem with type 1 diabetes. In the home setting, we conducted a pilot study to evaluate the safety of a system consisting of an insulin pump and continuous glucose monitor communicating wirelessly with a bedside computer running an algorithm that temporarily suspends insulin delivery when hypoglycemia is predicted. After the run-in phase, a 21-night randomized trial was conducted in which each night was randomly assigned 2:1 to have either the predictive low-glucose suspend (PLGS) system active (intervention night) or inactive (control night). Three predictive algorithm versions were studied sequentially during the study for a total of 252 intervention and 123 control nights. The trial included 19 participants 18-56 years old with type 1 diabetes (hemoglobin A1c level of 6.0-7.7%) who were current users of the MiniMed Paradigm® REAL-Time Revel™ System and Sof-sensor® glucose sensor (Medtronic Diabetes, Northridge, CA). With the final algorithm, pump suspension occurred on 53% of 77 intervention nights. Mean morning glucose level was 144±48 mg/dL on the 77 intervention nights versus 133±57 mg/dL on the 37 control nights, with morning blood ketones >0.6 mmol/L following one intervention night. Overnight hypoglycemia was lower on intervention than control nights, with at least one value ≤70 mg/dL occurring on 16% versus 30% of nights, respectively, with the final algorithm. This study demonstrated that the PLGS system in the home setting is safe and feasible. The preliminary efficacy data appear promising with the final algorithm reducing nocturnal hypoglycemia by almost 50%.

  9. Nitrate removal from polluted water by using a vegetated floating system.

    PubMed

    Bartucca, Maria Luce; Mimmo, Tanja; Cesco, Stefano; Del Buono, Daniele

    2016-01-15

    Nitrate (NO3(-)) water pollution is one of the most prevailing and relevant ecological issues. For instance, the wide presence of this pollutant in the environment is dramatically altering the quality of superficial and underground waters. Therefore, we set up a floating bed vegetated with a terrestrial herbaceous species (Italian ryegrass) with the aim to remediate hydroponic solutions polluted with NO3(-). The floating bed allowed the plants to grow and achieve an adequate development. Ryegrass was not affected by the treatments. On the contrary, plant biomass production and total nitrogen content (N-K) increased proportionally to the amount of NO3(-) applied. Regarding to the water cleaning experiments, the vegetated floating beds permitted to remove almost completely all the NO3(-) added from the hydroponic solutions with an initial concentration of 50, 100 and 150 mg L(-1). Furthermore, the calculation of the bioconcentration factor (BCF) indicated this species as successfully applicable for the remediation of solutions polluted by NO3(-). In conclusion, the results highlight that the combination of ryegrass and the floating bed system resulted to be effective in the remediation of aqueous solutions polluted by NO3(-). Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Influence of hydroxypropyl methylcellulose on drug release pattern of a gastroretentive floating drug delivery system using a 3(2) full factorial design.

    PubMed

    Swain, Kalpana; Pattnaik, Satyanarayan; Mallick, Subrata; Chowdary, Korla Appana

    2009-01-01

    In the present investigation, controlled release gastroretentive floating drug delivery system of theophylline was developed employing response surface methodology. A 3(2) randomized full factorial design was developed to study the effect of formulation variables like various viscosity grades and contents of hydroxypropyl methylcellulose (HPMC) and their interactions on response variables. The floating lag time for all nine experimental trial batches were less than 2 min and floatation time of more than 12 h. Theophylline release from the polymeric matrix system followed non-Fickian anomalous transport. Multiple regression analysis revealed that both viscosity and content of HPMC had statistically significant influence on all dependent variables but the effect of these variables found to be nonlinear above certain threshold values.

  11. Floating cultivation of marine cyanobacteria using coal fly ash.

    PubMed

    Matsumoto, M; Yoshida, E; Takeyama, H; Matsunaga, T

    2000-01-01

    The aim of this study was to develop improved methodologies for bulk culturing of biotechnologically useful marine cyanobacteria in the open ocean. We have investigated the viability of using coal fly ash (CFA) blocks as the support medium in a novel floating culture system for marine micro-algae. The marine cyanobacterium Synechococcus sp. NKBG 040607 was found to adhere to floating CFA blocks in liquid culture medium. Maximum density of attached cells of 2.0 x 10(8) cells/cm2 was achieved using seawater. The marine cyanobacterium Synechococcus sp. NKBG 042902 weakly adhered to floating CFA blocks in BG-11 medium. Increasing the concentration of calcium ion in the culture medium enhanced adherence to CFA blocks.

  12. Formulation and evaluation of novel coated floating tablets of bergenin and cetirizine dihydrochloride for gastric delivery.

    PubMed

    He, Shuang; Li, Feng; Zhou, Dan; Du, Junrong; Huang, Yuan

    2012-10-01

    A novel coated gastric floating drug-delivery system (GFDDS) of bergenin (BN) and cetirizine dihydrochloride (CET) was developed. First, the pharmacodynamic studies were performed and the results revealed that the new compounds of bergenin/cetirizine dihydrochloride had comparative efficacy as commercial products (bergenin/chlorphenamine maleate) but with fewer side effects on central nervous system (CNS). Subsequently, bergenin was formulated as an extended-release core tablet while cetirizine dihydrochloride was incorporated into the gastric coating film for immediate release. The formulation of GFDDS was optimized by CET content uniformity test, in vitro buoyancy and drug release. Herein, the effects of sodium bicarbonate (effervescent), hydroxypropyl methylcellulose (HPMC, matrix polymer) and coating weight gain were investigated respectively. The optimized GFDDS exhibited good floating properties (buoyancy lag time < 2 min; floating duration > 10 h) and satisfactory drug-release profiles (immediate release of CET in 10 min and sustained release of BN for 12 h). In vivo gamma scintigraphy proved that the optimized GFDDS could retain in the stomach with a prolonged gastric retention time (GRT) of 5 h, and the coating layer showed no side effect for gastric retention. The novel coated gastric floating drug-delivery system offers a new approach to enhance BN's absorption at its absorption site and the efficacy of both CET and BN.

  13. Ozone isotope measurements in the stratosphere

    NASA Technical Reports Server (NTRS)

    Mauersberger, K.

    1987-01-01

    Mass spectrometer measurements of ozone made during two balloon flights included its heavy isotopes at mass 49 and 50. Both flights were flown during the day and during summer from Palestine, TX. At float altitudes above 42 km the enrichments in heavy ozone were 41 percent and 23 percent, respectively. The enrichment appears to be mass independent since, at high altitudes, both 49 and 50 show the same enhancement. During the descent the enrichment in heavy ozone decreased, faster during the first flight than during the second, reaching values between 15 and 20 percent above 30 km. Near and below this altitude another increase is observed. During a night flight, previously reported, an enhancement in heavy ozone of over 40 percent at 32 km was found, decreasing both toward higher and lower altitudes.

  14. Flight Operations Analysis Tool

    NASA Technical Reports Server (NTRS)

    Easter, Robert; Herrell, Linda; Pomphrey, Richard; Chase, James; Wertz Chen, Julie; Smith, Jeffrey; Carter, Rebecca

    2006-01-01

    Flight Operations Analysis Tool (FLOAT) is a computer program that partly automates the process of assessing the benefits of planning spacecraft missions to incorporate various combinations of launch vehicles and payloads. Designed primarily for use by an experienced systems engineer, FLOAT makes it possible to perform a preliminary analysis of trade-offs and costs of a proposed mission in days, whereas previously, such an analysis typically lasted months. FLOAT surveys a variety of prior missions by querying data from authoritative NASA sources pertaining to 20 to 30 mission and interface parameters that define space missions. FLOAT provides automated, flexible means for comparing the parameters to determine compatibility or the lack thereof among payloads, spacecraft, and launch vehicles, and for displaying the results of such comparisons. Sparseness, typical of the data available for analysis, does not confound this software. FLOAT effects an iterative process that identifies modifications of parameters that could render compatible an otherwise incompatible mission set.

  15. Stability and chaotification of vibration isolation floating raft systems with time-delayed feedback control.

    PubMed

    Li, Y L; Xu, D L; Fu, Y M; Zhou, J X

    2011-09-01

    This paper presents a systematic study on the stability of a two-dimensional vibration isolation floating raft system with a time-delayed feedback control. Based on the generalized Sturm criterion, the critical control gain for the delay-independent stability region and critical time delays for the stability switches are derived. The critical conditions can provide a theoretical guidance of chaotification design for line spectra reduction. Numerical simulations verify the correctness of the approach. Bifurcation analyses reveal that chaotification is more likely to occur in unstable region defined by these critical conditions, and the stiffness of the floating raft and mass ratio are the sensitive parameters to reduce critical control gain.

  16. Smart Novel Semi-Active Tuned Mass Damper for Fixed-Bottom and Floating Offshore Wind (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez Tsouroukdissian, Arturo

    2016-05-02

    The intention of this paper is to present the results of a novel smart semi-active tuned mass damper (SA-TMD), which mitigates unwanted loads for both fixed-bottom and floating offshore wind systems. (Presentation Format).

  17. Study of strain-stress behavior when reconstructing rotary kiln tyres from floating to welded-in type

    NASA Astrophysics Data System (ADS)

    Shchetinin, N. A.; Duganova, E. V.; Golubenko, N. V.; Novikov, I. A.; Korneev, A. S.

    2018-03-01

    The paper provides modeling results in the CAD/CAE SolidWorks system with embedded FE-analysis package SolidWorks Simulation to study the hardness of floating tyres during their reconstruction into welded-in tyres.

  18. Influence of different types of low substituted hydroxypropyl cellulose on tableting, disintegration, and floating behaviour of floating drug delivery systems

    PubMed Central

    Diós, Péter; Pernecker, Tivadar; Nagy, Sándor; Pál, Szilárd; Dévay, Attila

    2014-01-01

    The object of the present study is to evaluate the effect of application of low-substituted hydroxypropyl cellulose (L-HPC) 11 and B1 as excipients promoting floating in gastroretentive tablets. Directly compressed tablets were formed based on experimental design. Face-centred central composite design was applied with two factors and 3 levels, where amount of sodium alginate (X1) and L-HPC (X2) were the numerical factors. Applied types of L-HPCs and their 1:1 mixture were included in a categorical factor (X3). Studied parameters were floating lag time, floating time, floating force, swelling behaviour of tablets and dissolution of paracetamol, which was used as a model active substance. Due to their physical character, L-HPCs had different water uptake and flowability. Lower flowability and lower water uptake was observed after 60 min at L-HPC 11 compared to L-HPC B1. Shorter floating times were detected at L-HPC 11 and L-HPC mixtures with 0.5% content of sodium alginate, whereas alginate was the only significant factor. Evaluating results of drug release and swelling studies on floating tablets revealed correlation, which can serve to help to understand the mechanism of action of L-HPCs in the field development of gastroretentive dosage forms. PMID:26702261

  19. Evaluating the Cost, Safety, and Proliferation Risks of Small Floating Nuclear Reactors.

    PubMed

    Ford, Michael J; Abdulla, Ahmed; Morgan, M Granger

    2017-11-01

    It is hard to see how our energy system can be decarbonized if the world abandons nuclear power, but equally hard to introduce the technology in nonnuclear energy states. This is especially true in countries with limited technical, institutional, and regulatory capabilities, where safety and proliferation concerns are acute. Given the need to achieve serious emissions mitigation by mid-century, and the multidecadal effort required to develop robust nuclear governance institutions, we must look to other models that might facilitate nuclear plant deployment while mitigating the technology's risks. One such deployment paradigm is the build-own-operate-return model. Because returning small land-based reactors containing spent fuel is infeasible, we evaluate the cost, safety, and proliferation risks of a system in which small modular reactors are manufactured in a factory, and then deployed to a customer nation on a floating platform. This floating small modular reactor would be owned and operated by a single entity and returned unopened to the developed state for refueling. We developed a decision model that allows for a comparison of floating and land-based alternatives considering key International Atomic Energy Agency plant-siting criteria. Abandoning onsite refueling is beneficial, and floating reactors built in a central facility can potentially reduce the risk of cost overruns and the consequences of accidents. However, if the floating platform must be built to military-grade specifications, then the cost would be much higher than a land-based system. The analysis tool presented is flexible, and can assist planners in determining the scope of risks and uncertainty associated with different deployment options. © 2017 Society for Risk Analysis.

  20. Refrigerant directly cooled capacitors

    DOEpatents

    Hsu, John S [Oak Ridge, TN; Seiber, Larry E [Oak Ridge, TN; Marlino, Laura D [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN

    2007-09-11

    The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

  1. Induction and inhibition of diapause by the same photoperiod: experimental evidence for a "double circadian oscillator clock".

    PubMed

    Spieth, Hubert R; Xue, Fangsen; Strau, Katharina

    2004-12-01

    On the southern Iberian Peninsula, the seasonal life history of the large white butterfly, Pieris brassicae, comprises 2 different photoperiodically induced developmental arrests: a hibernation diapause at photophases < 11 h and an estivation diapause at photophases > 14 h. At intermediate photophases (12 h to 13 h), the butterfly responds with a nondiapause. Combined with the experimental setup to determine photosensitivity in insects, the different photoperiodic responses at long-, intermediate-, and short-night conditions were examined to gain more insight into the time measurement mechanism in P. brassicae. The study reveals evidence for a "double circadian oscillator clock" mechanism that is based on 2 submechanisms, a "short-night determining system" and a separate "long-night determining system." This conclusion was drawn from the facts that an LD 9:15 long-night induces a hibernation diapause but inhibits an estivation diapause and, conversely, that an LD 16:8 short-night inhibits a hibernation diapause but induces an estivation diapause. This opposite effect of the same photoperiod supports the argument for the existence of 2 independent targets for light-dark cycles, interpreted as 2 antagonistic time measurement systems. The existence and independence of 2 systems was further shown by differences in long-night versus short-night responses regarding photosensitivity, temperature dependence, and heritable factors. The long-night measurement system is most effective in the 5th larval stage, is highly affected by temperature, and is easy to manipulate by selective inbreeding. The short-night measurement system is most effective in the 4th larval stage, is largely temperature compensated, and is not affected by experimental manipulation of the longnight measurement system.

  2. The study to estimate the floating population in Seoul, Korea.

    PubMed

    Lee, Geon Woo; Lee, Yong Jin; Kim, Youngeun; Hong, Seung-Han; Kim, Soohwaun; Kim, Jeong Soo; Lee, Jong Tae; Shin, Dong Chun; Lim, Youngwook

    2017-01-01

    Traffic-related pollutants have been reported to increase the morbidity of respiratory diseases. In order to apply management policies related to motor vehicles, studies of the floating population living in cities are important. The rate of metro rail transit system use by passengers residing in Seoul is about 54% of total public transportation use. Through the rate of metro use, the people-flow ratios in each administrative area were calculated. By applying a people-flow ratio based on the official census count, the floating population in 25 regions was calculated. The reduced level of deaths among the floating population in 14 regions having the roadside monitoring station was calculated as assuming a 20% reduction of mobile emission based on the policy. The hourly floating population size was calculated by applying the hourly population ratio to the regional population size as specified in the official census count. The number of people moving from 5 a.m. to next day 1 a.m. could not be precisely calculated when the population size was applied, but no issue was observed that would trigger a sizable shift in the rate of population change. The three patterns of increase, decrease, and no change of population in work hours were analyzed. When the concentration of particulate matter less than 10 μm in aerodynamic diameter was reduced by 20%, the number of excess deaths varied according to the difference of the floating population. The effective establishment of directions to manage the pollutants in cities should be carried out by considering the floating population. Although the number of people using the metro system is only an estimate, this disadvantage was supplemented by calculating inflow and outflow ratio of metro users per time in the total floating population in each region. Especially, 54% of metro usage in public transport causes high reliability in application.

  3. Night vision: changing the way we drive

    NASA Astrophysics Data System (ADS)

    Klapper, Stuart H.; Kyle, Robert J. S.; Nicklin, Robert L.; Kormos, Alexander L.

    2001-03-01

    A revolutionary new Night Vision System has been designed to help drivers see well beyond their headlights. From luxury automobiles to heavy trucks, Night Vision is helping drivers see better, see further, and react sooner. This paper describes how Night Vision Systems are being used in transportation and their viability for the future. It describes recent improvements to the system currently in the second year of production. It also addresses consumer education and awareness, cost reduction, product reliability, market expansion and future improvements.

  4. Research on stability of nozzle-floating plate institution

    NASA Astrophysics Data System (ADS)

    Huang, Bin; Tao, Jiayue; Yi, Jiajing; Chen, Shijing

    2016-01-01

    In this paper, air hammer instability of nozzle-floating plate institution in gas lubricated force sensor were studied. Through establishment of the theoretical model for the analysis of the nozzle-floating plate institution stability, combined with air hammer stability judgment theorems, we had some simulation research on the radius of the nozzle, the radius of the pressure chamber, pressure chamber depth, orifice radius and the relationship between air supply pressure and bearing capacity, in order to explore the instability mechanism of nozzle-floating plate institution. For conducting experimental observations for the stability of two groups nozzle-floating plate institution, which have typical structural parameters conducted experimental observations. We set up a special experimental device, verify the correctness of the theoretical study and simulation results. This paper shows that in the nozzle-floating plate institution, increasing the nozzle diameter, reduced pressure chamber radius, reducing the depth of the pressure chamber and increase the supply orifice radius, and other measures is conducive to system stability. Results of this study have important implications for research and design of gas lubricated force sensor.

  5. Using optical flow for the detection of floating mines in IR image sequences

    NASA Astrophysics Data System (ADS)

    Borghgraef, Alexander; Acheroy, Marc

    2006-09-01

    In the first Gulf War, unmoored floating mines proved to be a real hazard for shipping traffic. An automated system capable of detecting these and other free-floating small objects, using readily available sensors such as infra-red cameras, would prove to be a valuable mine-warfare asset, and could double as a collision avoidance mechanism, and a search-and-rescue aid. The noisy background provided by the sea surface, and occlusion by waves make it difficult to detect small floating objects using only algorithms based upon the intensity, size or shape of the target. This leads us to look at the sequence of images for temporal detection characteristics. The target's apparent motion is such a determinant, given the contrast between the bobbing motion of the floating object and the strong horizontal component present in the propagation of the wavefronts. We have applied the Proesmans optical flow algorithm to IR video footage of practice mines, in order to extract the motion characteristic and a threshold on the vertical motion characteristic is then imposed to detect the floating targets.

  6. Instabilities caused by floating-point arithmetic quantization.

    NASA Technical Reports Server (NTRS)

    Phillips, C. L.

    1972-01-01

    It is shown that an otherwise stable digital control system can be made unstable by signal quantization when the controller operates on floating-point arithmetic. Sufficient conditions of instability are determined, and an example of loss of stability is treated when only one quantizer is operated.

  7. Experimental Study on New Multi-Column Tension-Leg-Type Floating Wind Turbine

    NASA Astrophysics Data System (ADS)

    Zhao, Yong-sheng; She, Xiao-he; He, Yan-ping; Yang, Jian-min; Peng, Tao; Kou, Yu-feng

    2018-04-01

    Deep-water regions often have winds favorable for offshore wind turbines, and floating turbines currently show the greatest potential to exploit such winds. This work established proper scaling laws for model tests, which were then implemented in the construction of a model wind turbine with optimally designed blades. The aerodynamic, hydrodynamic, and elastic characteristics of the proposed new multi-column tension-leg-type floating wind turbine (WindStar TLP system) were explored in the wave tank testing of a 1:50 scale model at the State Key Laboratory of Ocean Engineering at Shanghai Jiao Tong University. Tests were conducted under conditions of still water, white noise waves, irregular waves, and combined wind, wave, and current loads. The results established the natural periods of the motion, damping, motion response amplitude operators, and tendon tensions of the WindStar TLP system under different environmental conditions, and thus could serve as a reference for further research. Key words: floating wind turbine, model test, WindStar TLP, dynamic response

  8. In-service tests of the effectiveness of vibration control measures on the BART rail transit system

    NASA Astrophysics Data System (ADS)

    Saurenman, Hugh; Phillips, James

    2006-06-01

    This paper presents results of a number of vibration measurements of the different track forms used on the current San Francisco Bay Area Rapid Transit (BART) system including floating slab, resiliently supported half-ties and high-resilience direct fixation fasteners in subway and one section of floating slab used on at-grade track. The goal was to obtain data that would improve the predictions of future vibration levels and perhaps lead to more cost effective vibration mitigation strategies for the proposed BART extension to San Jose. The tests show that the floating slabs are performing much as designed, the resiliently supported half-ties are less effective than expected, and the high resilience track fasteners are probably performing as expected although the results are clouded because of severe rail corrugation in the area where the new fasteners were installed. One unanticipated result is the apparent interaction of the floating slab resonance, the wheel rotation frequency, the bogie dynamics, and vibration propagation characteristics of the ground.

  9. Characterizations of Plasticized Polymeric Film Coatings for Preparing Multiple-Unit Floating Drug Delivery Systems (muFDDSs) with Controlled-Release Characteristics

    PubMed Central

    Chen, Ying-Chen; Wang, Yu-Chun; Ho, Hsiu-O; Sheu, Ming-Thau

    2014-01-01

    Effervescent multiple-unit floating drug delivery systems (muFDDSs) consisting of drug (lorsartan)- and effervescent (sodium bicarbonate)-containing pellets were characterized in this study. The mechanical properties (stress and strain at rupture, Young’s modulus, and toughness) of these plasticized polymeric films of acrylic (Eudragit RS, RL, and NE) and cellulosic materials (ethyl cellulose (EC), and Surelease) were examined by a dynamic mechanical analyzer. Results demonstrated that polymeric films prepared from Surelease and EC were brittle with less elongation compared to acrylic films. Eudragit NE films were very flexible in both the dry and wet states. Because plasticizer leached from polymeric films during exposure to the aqueous medium, plasticization of wet Eudragit RS and RL films with 15% triethyl citrate (TEC) or diethyl phthalate (DEP) resulted in less elongation. DEP might be the plasticizer of choice among the plasticizers examined in this study for Eudragit RL to provide muFDDSs with a short time for all pellets to float (TPF) and a longer period of floating. Eudragit RL and RS at a 1∶1 ratio plasticized with 15% DEP were optimally selected as the coating membrane for the floating system. Although the release of losartan from the pellets was still too fast as a result of losartan being freely soluble in water, muFDDSs coated with Eudragit RL and RS at a 1∶1 ratio might have potential use for the sustained release of water-insoluble or the un-ionized form of drugs from gastroretentive drug delivery systems. PMID:24967594

  10. Use of Circadian Lighting System to improve night shift alertness and performance of NRC Headquarters Operations Officers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.; Morisseau, D.; Murphy, N.M.

    1995-04-01

    The Nuclear Regulatory Commission`s (NRC) Headquarters Operations Officers (HOOs) receive and respond to events reported in the nuclear industry on a 24-hour basis. The HOOs have reported reduced alertness on the night shift, leading to a potential deterioration in their on-shift cognitive performance during the early morning hours. For some HOOs, maladaptation to the night shift was also reported to be the principal cause of: (a) reduced alertness during the commute to and from work, (b) poor sleep quality, and (c) personal lifestyle problems. ShiftWork Systems, Inc. (SWS) designed and installed a Circadian Lighting System (CLS) at both the Bethesdamore » and Rockville HOO stations with the goal of facilitating the HOOs physiological adjustment to their night shift schedules. The data indicate the following findings: less subjective fatigue on night shifts; improved night shift alertness and mental performance; higher HOO confidence in their ability to assess event reports; longer, deeper and more restorative day sleep after night duty shifts; swifter adaptation to night work; and a safer commute, particularly for those with extensive drives.« less

  11. Floating seal system for rotary devices

    DOEpatents

    Banasiuk, Hubert A.

    1983-01-01

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10.degree. to about 30.degree. in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device.

  12. Floating seal system for rotary devices

    DOEpatents

    Banasiuk, H.A.

    1983-08-23

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10[degree] to about 30[degree] in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device. 5 figs.

  13. Removal of nutrients and veterinary antibiotics from swine wastewater by a constructed macrophyte floating bed system.

    PubMed

    Xian, Qiming; Hu, Lixia; Chen, Hancheng; Chang, Zhizhou; Zou, Huixian

    2010-12-01

    The potential of three varieties of Italian ryegrass (Lolium multiflorum Lam.), Dryan, Tachimasari and Waseyutaka, to improve the water quality of swine wastewater was evaluated using a constructed macrophyte floating bed system. With respect to reductions in levels of nutrients, chemical oxygen demand (COD), and sulfonamide antimicrobials (SAs, including sulfadiazine, sulfamethazine, and sulfamethoxazole), Dryan performed better than Tachimasari and Waseyutaka. For Dryan, total N was reduced by 84.0%, total P by 90.4%, COD by 83.4% and sulfonamide antimicrobials by 91.8-99.5%. Similar results were observed for Tachimasari and Waseyutaka. The results indicated that the treatment of swine wastewater using the constructed macrophyte floating bed system was effective in the removal of nutrients and veterinary antibiotics. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werne, Roger W.; Sampayan, Stephen; Harris, John Richardson

    This patent document discloses high voltage switches that include one or more electrically floating conductor layers that are isolated from one another in the dielectric medium between the top and bottom switch electrodes. The presence of the one or more electrically floating conductor layers between the top and bottom switch electrodes allow the dielectric medium between the top and bottom switch electrodes to exhibit a higher breakdown voltage than the breakdown voltage when the one or more electrically floating conductor layers are not present between the top and bottom switch electrodes. This increased breakdown voltage in the presence of onemore » or more electrically floating conductor layers in a dielectric medium enables the switch to supply a higher voltage for various high voltage circuits and electric systems.« less

  15. Flight Testing of Night Vision Systems in Rotorcraft (Test en vol de systemes de vision nocturne a bord des aeronefs a voilure tournante)

    DTIC Science & Technology

    2007-07-01

    SAS System Analysis and Studies Panel • SCI Systems Concepts and Integration Panel • SET Sensors and Electronics Technology Panel These...Daylight Readability 4-2 4.1.4 Night-Time Readability 4-2 4.1.5 NVIS Radiance 4-2 4.1.6 Human Factors Analysis 4-3 4.1.7 Flight Tests 4-3 4.1.7.1...position is shadowing. Moonlight creates shadows during night-time just as sunlight does during the day. Understanding what cannot be seen in night-time

  16. 10. LOOKING DOWN ON TUG AND CAR FLOAT BEING UNLOADED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. LOOKING DOWN ON TUG AND CAR FLOAT BEING UNLOADED AT BRIDGE NO. 11 SHOWING TRACK, LOCKING MECHANISMS, AND MOORING WINCH IN FOREGROUND. LOOKING EAST. - Greenville Yard, Transfer Bridge System, Port of New York/New Jersey, Upper New York Bay, Jersey City, Hudson County, NJ

  17. Effects of a night-team system on resident sleep and work hours.

    PubMed

    Chua, Kao-Ping; Gordon, Mary Beth; Sectish, Theodore; Landrigan, Christopher P

    2011-12-01

    In 2009, Children's Hospital Boston implemented a night-team system on general pediatric wards to reduce extended work shifts. Residents worked 5 consecutive nights for 1 week and worked day shifts for the remainder of the rotation. Of note, resident staffing at night decreased under this system. The objective of this study was to assess the effects of this system on resident sleep and work hours. We conducted a prospective cohort study in which residents on the night-team system logged their sleep and work hours on work days. These data were compared with similar data collected in 2004, when there was a traditional call system. In 2004 and 2009, mean shift length was 15.22 ± 6.86 and 12.92 ± 5.70 hours, respectively (P = .161). Daily work hours were 10.49 ± 6.85 and 8.79 ± 6.42 hours, respectively (P = .08). Nightly sleep time decreased from 6.72 ± 2.60 to 4.77 ± 2.46 hours (P < .001). Total sleep time decreased from 7.50 ± 3.13 to 5.47 ± 2.34 hours (P < .001). Implementation of a night-team system was unexpectedly associated with decreased sleep hours. As residency programs create work schedules that are compliant with the 2011 Accreditation Council for Graduate Medical Education duty-hour standards, resident sleep should be monitored carefully.

  18. Interpretation of IEEE-854 floating-point standard and definition in the HOL system

    NASA Technical Reports Server (NTRS)

    Carreno, Victor A.

    1995-01-01

    The ANSI/IEEE Standard 854-1987 for floating-point arithmetic is interpreted by converting the lexical descriptions in the standard into mathematical conditional descriptions organized in tables. The standard is represented in higher-order logic within the framework of the HOL (Higher Order Logic) system. The paper is divided in two parts with the first part the interpretation and the second part the description in HOL.

  19. An experimental study of the effect of mooring systems on the dynamics of a SPAR buoy-type floating offshore wind turbine

    NASA Astrophysics Data System (ADS)

    Hong, Sinpyo; Lee, Inwon; Park, Seong Hyeon; Lee, Cheolmin; Chun, Ho-Hwan; Lim, Hee Chang

    2015-09-01

    An experimental study of the effect of mooring systems on the dynamics of a SPAR buoy-type floating offshore wind turbine is presented. The effects of the Center of Gravity (COG), mooring line spring constant, and fair-lead location on the turbine's motion in response to regular waves are investigated. Experimental results show that for a typical mooring system of a SPAR buoy-type Floating Offshore Wind Turbine (FOWT), the effect of mooring systems on the dynamics of the turbine can be considered negligible. However, the pitch decreases notably as the COG increases. The COG and spring constant of the mooring line have a negligible effect on the fairlead displacement. Numerical simulation and sensitivity analysis show that the wind turbine motion and its sensitivity to changes in the mooring system and COG are very large near resonant frequencies. The test results can be used to validate numerical simulation tools for FOWTs.

  20. A novel free floating accelerometer force balance system for shock tunnel applications

    NASA Astrophysics Data System (ADS)

    Joarder, R.; Mahaptra, D. R.; Jagadeesh, G.

    In order to overcome the interference of the model mounting system with the external aerodynamics of the body during shock tunnel testing, a new free floating internally mountable balance system that ensures unrestrained model motion during testing has been designed, fabricated and tested. Minimal friction ball bearings are used for ensuring the free floating condition of the model during tunnel testing. The drag force acting on a blunt leading edge flat plate at hypersonic Mach number has been measured using the new balance system. Finite element model (FEM) and CFD are exhaustively used in the design as well as for calibrating the new balance system. The experimentally measured drag force on the blunt leading edge flat plate at stagnation enthalpy of 0.7 and 1.2 MJ/kg and nominal Mach number of 5.75 matches well with FEM results. The concept can also be extended for measuring all the three fundamental aerodynamic forces in short duration test facilities like free piston driven shock tunnels.

  1. Long-Term Observations of Ocean Biogeochemistry with Nitrate and Oxygen Sensors in Apex Profiling Floats

    NASA Astrophysics Data System (ADS)

    Johnson, K. S.; Coletti, L.; Jannasch, H.; Martz, T.; Swift, D.; Riser, S.

    2008-12-01

    Long-term, autonomous observations of ocean biogeochemical cycles are now feasible with chemical sensors in profiling floats. These sensors will enable decadal-scale observations of trends in global ocean biogeochemical cycles. Here, we focus on measurements on nitrate and dissolved oxygen. The ISUS (In Situ Ultraviolet Spectrophotometer) optical nitrate sensor has been adapted to operate in a Webb Research, Apex profiling float. The Apex float is of the type used in the Argo array and is designed for multi-year, expendable deployments in the ocean. Floats park at 1000 m depth and make 60 nitrate and oxygen measurements at depth intervals ranging from 50 m below 400 m to 5 m in the upper 100 m as they profile to the surface. All data are transmitted to shore using the Iridium telemetry system and they are available on the Internet in near-real time. Floats equipped with ISUS and an Aanderaa oxygen sensor are capable of making 280 vertical profiles from 1000 m. At a 5 day cycle time, the floats should have nearly a four year endurance. Three floats have now been deployed at the Hawaii Ocean Time series station (HOT), Ocean Station Papa (OSP) in the Gulf of Alaska and at 50 South, 30 East in the Southern Ocean. Two additional floats are designated for deployment at the Bermuda Atlantic Time Series station (BATS) and in the Drake Passage. The HOT float has made 56 profiles over 260 days and should continue operating for 3 more years. Nitrate concentrations are in excellent agreement with the long-term mean observed at HOT. No significant long-term drift in sensor response has occurred. A variety of features have been observed in the HOT nitrate data that are linked to contemporaneous changes in oxygen production and mesoscale dynamics. The impacts of these features will be briefly described. The Southern Ocean float has operated for 200 days and is now observing reinjection of nitrate into surface waters as winter mixing occurs(surface nitrate > 24 micromolar). We expect that the OSP and Southern Ocean floats will provide a quantitative measurement of the timing and magnitude of the spring bloom via the drawdown of surface nitrate. We are funded through NSF and NOPP to continue float deployments at HOT, BATS, OSP and the Southern Ocean for the next 3 years and to refine the sensor so it can be offered as a commercial option for all float users. New sensors in development for float deployments include a stable ISFET pH sensor.

  2. Floating matrix tablets based on low density foam powder: effects of formulation and processing parameters on drug release.

    PubMed

    Streubel, A; Siepmann, J; Bodmeier, R

    2003-01-01

    The aim of this study was to develop and physicochemically characterize single unit, floating controlled drug delivery systems consisting of (i). polypropylene foam powder, (ii). matrix-forming polymer(s), (iii). drug, and (iv). filler (optional). The highly porous foam powder provided low density and, thus, excellent in vitro floating behavior of the tablets. All foam powder-containing tablets remained floating for at least 8 h in 0.1 N HCl at 37 degrees C. Different types of matrix-forming polymers were studied: hydroxypropyl methylcellulose (HPMC), polyacrylates, sodium alginate, corn starch, carrageenan, gum guar and gum arabic. The tablets eroded upon contact with the release medium, and the relative importance of drug diffusion, polymer swelling and tablet erosion for the resulting release patterns varied significantly with the type of matrix former. The release rate could effectively be modified by varying the "matrix-forming polymer/foam powder" ratio, the initial drug loading, the tablet geometry (radius and height), the type of matrix-forming polymer, the use of polymer blends and the addition of water-soluble or water-insoluble fillers (such as lactose or microcrystalline cellulose). The floating behavior of the low density drug delivery systems could successfully be combined with accurate control of the drug release patterns.

  3. Design and evaluation of hydrophobic coated buoyant core as floating drug delivery system for sustained release of cisapride

    PubMed Central

    Jacob, Shery; Nair, Anroop B; Patil, Pandurang N

    2010-01-01

    An inert hydrophobic buoyant coated–core was developed as floating drug delivery system (FDDS) for sustained release of cisapride using direct compression technology. Core contained low density, porous ethyl cellulose, which was coated with an impermeable, insoluble hydrophobic coating polymer such as rosin. It was further seal coated with low viscosity hydroxypropyl methyl cellulose (HPMC E15) to minimize moisture permeation and better adhesion with an outer drug layer. It was found that stable buoyant core was sufficient to float the tablet more than 8 h without the aid of sodium bicarbonate and citric acid. Sustained release of cisapride was achieved with HPMC K4M in the outer drug layer. The floating lag time required for these novel FDDS was found to be zero, however it is likely that the porosity or density of the core is critical for floatability of these tablets. The in vitro release pattern of these tablets in simulated gastric fluid showed the constant and controlled release for prolonged time. It can be concluded that the hydrophobic coated buoyant core could be used as FDDS for gastroretentive delivery system of cisapride or other suitable drugs. PMID:24825997

  4. WindWaveFloat (WWF): Final Scientific Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alla Weinstein; Roddier, Dominique; Banister, Kevin

    2012-03-30

    Principle Power Inc. and National Renewable Energy Lab (NREL) have completed a contract to assess the technical and economic feasibility of integrating wave energy converters into the WindFloat, resulting in a new concept called the WindWaveFloat (WWF). The concentration of several devices on one platform could offer a potential for both economic and operational advantages. Wind and wave energy converters can share the electrical cable and power transfer equipment to transport the electricity to shore. Access to multiple generation devices could be simplified, resulting in cost saving at the operational level. Overall capital costs may also be reduced, provided thatmore » the design of the foundation can be adapted to multiple devices with minimum modifications. Finally, the WindWaveFloat confers the ability to increase energy production from individual floating support structures, potentially leading to a reduction in levelized energy costs, an increase in the overall capacity factor, and greater stability of the electrical power delivered to the grid. The research conducted under this grant investigated the integration of several wave energy device types into the WindFloat platform. Several of the resulting system designs demonstrated technical feasibility, but the size and design constraints of the wave energy converters (technical and economic) make the WindWaveFloat concept economically unfeasible at this time. Not enough additional generation could be produced to make the additional expense associated with wave energy conversion integration into the WindFloat worthwhile.« less

  5. Autonomous magnetic float zone microgravity crystal growth application to TiC and GaAs

    NASA Astrophysics Data System (ADS)

    Chan, Tony Y.-T.; Choi, Sang-Keun

    1992-10-01

    The floating zone process is ideal for high temperature (greater than 3000 K) growth of titanium carbide because it is containerless. However, float zoning requires small melt volumes in order to maintain a stable melt configuration. The short melt columns make it difficult to achieve a controlled thermal profile, a necessity for producing crystals of high quality. Thus, an automated control strategy based upon continuous monitoring of the growth process with processing parameters adjusted to values based upon the physical transport processes of the growth process is very desirable for maintaining stability and reproducibility of the process. The present work developed a Float-zone Acquisition and Control Technology (FACT) system which uses relations derived by combining empirical relations with a knowledge data base deduced from detailed numerical analysis of fluid mechanics and thermal transport of the growth process. The FACT system was assembled, tested and employed to grow two TiC ingots. One of the ingots was characterized by x-ray diffraction at different axial locations. The x-ray rocking curves showed consistent characteristics of a manually grown ingot. It was also found that with the FACT system, the process conditions can be operated closer to the stability limits, due to fast response time and repetitive amounts of adjustment from the FACT system. The FACT system shows a major potential in growing quality TiC crystals in a cost-effective manner.

  6. Raft and floating radio frequency identification (RFID) antenna systems for detecting and estimating abundance of PIT-tagged fish in rivers

    USGS Publications Warehouse

    Fetherman, Eric R.; Avila, Brian W.; Winkelman, Dana L.

    2016-01-01

    Portable radio frequency identification (RFID) PIT tag antenna systems are increasingly being used in studies examining aquatic animal movement, survival, and habitat use, and their design flexibility permits application in a wide variety of settings. We describe the construction, use, and performance of two portable floating RFID PIT tag antenna systems designed to detect fish that were unavailable for recapture using stationary antennas or electrofishing. A raft antenna system was designed to detect and locate PIT-tagged fish in relatively long (i.e., ≥10 km) river reaches, and consisted of two antennas: (1) a horizontal antenna (4 × 1.2 m) installed on the bottom of the raft and used to detect fish in shallower river reaches (<1 m), and (2) a vertical antenna (2.7 × 1.2 m) for detecting fish in deeper pools (≥1 m). Detection distances of the horizontal antenna were between 0.7 and 1.0 m, and detection probability was 0.32 ± 0.02 (mean ± SE) in a field test using rocks marked with 32-mm PIT tags. Detection probability of PIT-tagged fish in the Cache la Poudre River, Colorado, using the raft antenna system, which covered 21% of the wetted area, was 0.14 ± 0.14. A shore-deployed floating antenna (14.6 × 0.6 m), which covered 100% of the wetted area, was designed for use by two operators for detecting and locating PIT-tagged fish in shorter (i.e., <2 km) river reaches. Detection distances of the shore-deployed floating antenna were between 0.7 and 0.8 m, and detection probabilities during field deployment in the St. Vrain River exceeded 0.52. The shore-deployed floating antenna was also used to estimate abundance of PIT-tagged fish. Results suggest that the shore-deployed floating antenna could be used as an alternative to estimating abundance using traditional sampling methods such as electrofishing.

  7. VLSI Design Techniques for Floating-Point Computation

    DTIC Science & Technology

    1988-11-18

    J. C. Gibson, The Gibson Mix, IBM Systems Development Division Tech. Report(June 1970). [Heni83] A. Heninger, The Zilog Z8070 Floating-Point...Broadcast Oock Gen. ’ itp Divide Module Module byN Module Oock Communication l I T Oock Communication Bus Figure 7.2. Clock Distribution between

  8. 32 CFR 736.5 - Disposition of real and personal property under special statutory authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of Naval Operations, applications for boats to the Naval Sea Systems Command, and applications for barges, floating drydocks, and other floating construction equipment to the Naval Facilities Engineering... Disposition Manual. (g) Disposition of equipment for research. Under the act of September 6, 1958 (72 Stat...

  9. Seabird bycatch mitigation trials in artisanal demersal longliners of the Western Mediterranean.

    PubMed

    Cortés, Verónica; González-Solís, Jacob

    2018-01-01

    High numbers of seabirds are killed annually worldwide in longline fisheries. In the Mediterranean, this mortality is seriously affecting the viability of seabird populations, in particular of the three endemic shearwaters. Even so, there is currently no specific seabird mitigation requirements for the longline fleet operating in this area. From 2013 to 2014, we assessed the efficiency and practical applicability of four mitigation measures on artisanal demersal longliners targeting European hake (Merluccius merluccius) in the western Mediterranean: night setting, tori line, weighted lines and artificial baits. We performed fifty-two pairs of experimental (with the tested mitigation measure) and control settings (without any measure), and compared their effects on seabird interactions and fish catches. In addition, we estimated the longline sink rates and the seabird access area to baited hooks in different longline configurations. Night setting reduced bycatch risk without affecting target and non-commercial fish catches. The tori line may have reduced the bycatch risk by displacing bait attacks beyond the end of the line, but at this distance shearwaters could still access to the baits and the streamers did not deter birds under calm wind conditions. Weighted lines increased sink rate, but it resulted in only a minor reduction of the seabird access window to baited hooks and led to some operational problems during the setting. Artificial baits substantially reduced commercial catches. Moreover, the seabird access to the baited hooks was influenced by the longline configuration, the setting speed and the relative position to the floats and weights. So far, night setting stands out as the best mitigation measure for reducing bycatch levels without compromising target catches in demersal longliners. Ideally, these results should be confirmed in longliners targeting species other than European hake.

  10. Integration of animal behaviors under stresses with different time courses

    PubMed Central

    Zheng, Lun; Zheng, Xigeng

    2014-01-01

    We used animal models of “forced swim stress” and “chronic unpredictable stress”, and tried to reveal whether a passive coping style of high flotation behavior in forced swim stress predicts anhedonia behavior after chronic unpredictable stress, and whether the dopamine system regulates floating and anhedonia behaviors. Our results confirmed that depression-prone rats use “floating behavior” as a coping strategy in forced swim stress and more readily suffer from anhedonia during chronic unpredictable stress. Intraperitoneal injection or nucleus accumbens microinjection of the dopamine 2/3 receptor subtype agonist ropinirole reduced floating behaviors in depression-prone animals, but increased sucrose preference in rats showing anhedonia. These data indicate that floating behavior is a defensive mode that is preferred by susceptible individuals under conditions of acute stress. Simultaneously, these animals more readily experienced anhedonia under long-term stress; that is, they were more readily affected by depression. Our results suggest that dopamine 2/3 receptor subtypes in the nucleus accumbens play an important role in floating behaviors and anhedonia. PMID:25317159

  11. Dynamics modeling and loads analysis of an offshore floating wind turbine

    NASA Astrophysics Data System (ADS)

    Jonkman, Jason Mark

    The vast deepwater wind resource represents a potential to use offshore floating wind turbines to power much of the world with renewable energy. Many floating wind turbine concepts have been proposed, but dynamics models, which account for the wind inflow, aerodynamics, elasticity, and controls of the wind turbine, along with the incident waves, sea current, hydrodynamics, and platform and mooring dynamics of the floater, were needed to determine their technical and economic feasibility. This work presents the development of a comprehensive simulation tool for modeling the coupled dynamic response of offshore floating wind turbines, the verification of the simulation tool through model-to-model comparisons, and the application of the simulation tool to an integrated loads analysis for one of the promising system concepts. A fully coupled aero-hydro-servo-elastic simulation tool was developed with enough sophistication to address the limitations of previous frequency- and time-domain studies and to have the features required to perform loads analyses for a variety of wind turbine, support platform, and mooring system configurations. The simulation capability was tested using model-to-model comparisons. The favorable results of all of the verification exercises provided confidence to perform more thorough analyses. The simulation tool was then applied in a preliminary loads analysis of a wind turbine supported by a barge with catenary moorings. A barge platform was chosen because of its simplicity in design, fabrication, and installation. The loads analysis aimed to characterize the dynamic response and to identify potential loads and instabilities resulting from the dynamic couplings between the turbine and the floating barge in the presence of combined wind and wave excitation. The coupling between the wind turbine response and the barge-pitch motion, in particular, produced larger extreme loads in the floating turbine than experienced by an equivalent land-based turbine. Instabilities were also found in the system. The influence of conventional wind turbine blade-pitch control actions on the pitch damping of the floating turbine was also assessed. Design modifications for reducing the platform motions, improving the turbine response, and eliminating the instabilities are suggested. These suggestions are aimed at obtaining cost-effective designs that achieve favorable performance while maintaining structural integrity.

  12. Ships as future floating farm systems?

    PubMed

    Moustafa, Khaled

    2018-04-03

    Environmental and agriculture challenges such as severe drought, desertification, sprawling cities and shrinking arable lands in large regions in the world compel us to think about alternative and sustainable farming systems. Ongoing projects to build floating cities in the sea suggest that building specific ships for farming purposes (as farming ships or farming boats) would also be attainable to introduce new farming surfaces and boost food production worldwide to cope with food insecurity issues.

  13. Deflection of Resilient Materials for Reduction of Floor Impact Sound

    PubMed Central

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor. PMID:25574491

  14. Deflection of resilient materials for reduction of floor impact sound.

    PubMed

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.

  15. Structural analysis and design for the development of floating photovoltaic energy generation system

    NASA Astrophysics Data System (ADS)

    Yoon, S. J.; Joo, H. J.; Kim, S. H.

    2018-06-01

    In this paper, we discussed the structural analysis and design for the development of floating photovoltaic energy generation system. Series of research conducted to develop the system from the analysis and design of the structural system to the installation of the system discussed. In the structural system supporting solar panels PFRP materials and SMC FRP materials used. A unit module structure is fabricated and then the unit module structures are connected each other to assemble whole PV energy generation complex. This system connected directly to the power grid system. In addition, extensive monitoring for the efficiency of electricity generation and the soundness of the structural system is in progress for the further system enhancement.

  16. Design and in vitro/in vivo evaluation of sustained-release floating tablets of itopride hydrochloride.

    PubMed

    Ahmed, Sayed M; Ahmed Ali, Adel; Ali, Ahmed Ma; Hassan, Omiya A

    2016-01-01

    The aim of the present study was to improve the bioavailability of itopride (ITO) and sustain its action by formulating as a floating dosage form. Sustained-release floating tablets of ITO hydrochloride (HCl) were prepared by direct compression using different hydrocolloid polymers such as hydroxypropyl methylcellulose and ethylcellulose and/or methacrylic acid polymers Eudragit RSPM and Carbopol 934P. The floating property was achieved using an effervescent mixture of sodium bicarbonate and anhydrous citric acid (1:1 mol/mol). Hardness, friability, content uniformity, and dissolution rate of the prepared floating tablets were evaluated. The formulation F 10 composed of 28.5% Eudragit RSPM, 3% NaHCO 3 , and 7% citric acid provided sustained drug release. In vitro results showed sustained release of F 10 where the drug release percentage was 96.51%±1.75% after 24 hours ( P =0.031). The pharmacokinetic results indicated that the area under the curve (AUC 0-∞ ) of the prepared sustained-release floating tablets at infinity achieved 93.69 µg·h/mL compared to 49.89 µg·h/mL for the reference formulation (Ganaton ® ) and the relative bioavailability of the sustained-release formulation F 10 increased to 187.80% ( P =0.022). The prepared floating tablets of ITO HCl (F 10 ) could be a promising drug delivery system with sustained-release action and enhanced drug bioavailability.

  17. The effect of floating vegetation on denitrification and greenhouse gas production in wetland mesocosms

    NASA Astrophysics Data System (ADS)

    Jacobs, A. E.; Harrison, J. A.

    2012-12-01

    Anthropogenic intensification of nitrogen (N) loading to aquatic ecosystems is widespread and can lead to the degradation of these systems. Wetlands are important sites for N removal via denitrification, the microbially mediated reduction of reactive nitrate to inert N2 gas, but they can also produce high levels of greenhouse gases. Floating plants play an important role in encouraging denitrification, since they create low oxygen conditions that may favor denitrification. We investigated whether wetland sediments with floating plant cover had higher denitrification and greenhouse gas production rates than wetland sediments without floating plants. Replicate flow-through mesocosms with wetland sediment and water were constructed in a growth chamber to mimic the wetland where the sediment and water were collected. Mesocosm treatments were covered with floating vegetation (duckweed), an opaque tarp, or no cover to determine how cover type affects denitrification and greenhouse gas production and whether biotic or abiotic factors are likely responsible for observed differences. Denitrification and greenhouse gas production rates were calculated by measuring excess N2 gas, methane, and nitrous oxide concentrations in the water column and measuring the gas exchange rates between the water column and the atmosphere. Gas exchange rates were measured using an inert volatile tracer added to the water column and accumulation of gas in the mesocosm headspace. Additional mesocosm experiments were performed to determine how duckweed-dominated wetland systems respond to nitrogen loading and which mechanism for lowering dissolved oxygen concentrations is important in affecting denitrification under floating vegetation. Mesocosms with floating vegetation had lower dissolved oxygen than no cover or tarp-covered mesocosms, which is consistent with field and literature observations. Water flowing out of the mesocosms had statistically lower total nitrogen and nitrate concentrations compared to inflow water, and calculated denitrification was statistically higher in the floating vegetation treatments compared to the other treatments. Greenhouse gas production, measured in CO2 equivalents for N2O and CH4, was highly variable and not statistically different between the treatments. Denitrification in the tarp covered mesocosms was similar to the no-cover treatment, indicating that biotic effects in the floating vegetation treatment may be important in lowering water column oxygen levels and increasing denitrification. Understanding how floating vegetation affects total nitrogen loss, denitrification, and greenhouse gas production can be used to weigh ecological costs and benefits of different vegetation types, especially in constructed and managed wetlands.

  18. General purpose free floating platform for KC-135 flight experimentation

    NASA Technical Reports Server (NTRS)

    Borchers, Bruce A.; Yendler, Boris S.; Kliss, Mark H.; Gonzales, Andrew A.; Edwards, Mark T.

    1994-01-01

    The Controlled Ecological Life Support Systems (CELSS) program is evaluating higher plants as a means of providing life support functions aboard space craft. These plant systems will be capable of regenerating air and water while meeting some of the food requirements of the crew. In order to grow plants in space, a series of systems are required to provide the necessary plant support functions. Some of the systems required for CELSS experiments are such that is is likely that existing technologies will require refinement, or novel technologies will need to be developed. To evaluate and test these technologies, a series of KC-135 precursor flights are being proposed. A general purpose free floating experiment platform is being developed to allow the KC-135 flights to be used to their fullest. This paper will outline the basic design for the CELSS Free Floating Test Bed (FFTB), and the requirements for the individual subsystems. Several preliminary experiments suitable for the free floater will also be discussed.

  19. Langmuir Probe Measurements in a Grid-Assisted Magnetron Sputtering System

    NASA Astrophysics Data System (ADS)

    Sagás, Julio César; Pessoa, Rodrigo Sávio; Maciel, Homero Santiago

    2018-02-01

    The grid-assisted magnetron sputtering is a variation of the magnetron sputtering commonly used for thin film deposition. In this work, Langmuir probe measurements were performed in such a system by using the grid under two basic and practical electrical conditions, i.e., floating and grounded. The results show that grounding the grid leads to an enhancement of the plasma confinement and to increases in both floating and plasma potential, as inferred from the probe characteristics. The grounded grid drains electrons from the plasma, acting as an auxiliary anode and reducing the plasma diffusion toward the chamber walls. For the same discharge current, the improved confinement results in a lower electron temperature when compared to floating condition, although the electron densities are comparable in both cases.

  20. Expert Systems on Multiprocessor Architectures. Volume 4. Technical Reports

    DTIC Science & Technology

    1991-06-01

    Floated-Current-Time0 -> The time that this function is called in user time uflts, expressed as a floating point number. Halt- Poligono Arrests the...default a statistics file will be printed out, if it can be. To prevent this make No-Statistics true. Unhalt- Poligono Unarrests the process in which the

  1. 30 CFR 250.1911 - What criteria for hazards analyses must my SEMS program meet?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER... to the seabed (i.e., mobile offshore drilling units; floating production systems; floating production..., production, and transportation activities for oil, gas, or sulphur from areas leased in the OCS. Facilities...

  2. 30 CFR 250.1911 - What criteria for hazards analyses must my SEMS program meet?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Safety...., mobile offshore drilling units; floating production systems; floating production, storage and offloading... transportation activities for oil, gas, or sulphur from areas leased in the OCS. Facilities also include DOI...

  3. Integrated dual-tomography for refractive index analysis of free-floating single living cell with isotropic superresolution.

    PubMed

    B, Vinoth; Lai, Xin-Ji; Lin, Yu-Chih; Tu, Han-Yen; Cheng, Chau-Jern

    2018-04-13

    Digital holographic microtomography is a promising technique for three-dimensional (3D) measurement of the refractive index (RI) profiles of biological specimens. Measurement of the RI distribution of a free-floating single living cell with an isotropic superresolution had not previously been accomplished. To the best of our knowledge, this is the first study focusing on the development of an integrated dual-tomographic (IDT) imaging system for RI measurement of an unlabelled free-floating single living cell with an isotropic superresolution by combining the spatial frequencies of full-angle specimen rotation with those of beam rotation. A novel 'UFO' (unidentified flying object) like shaped coherent transfer function is obtained. The IDT imaging system does not require any complex image-processing algorithm for 3D reconstruction. The working principle was successfully demonstrated and a 3D RI profile of a single living cell, Candida rugosa, was obtained with an isotropic superresolution. This technology is expected to set a benchmark for free-floating single live sample measurements without labeling or any special sample preparations for the experiments.

  4. Floating-point system quantization errors in digital control systems

    NASA Technical Reports Server (NTRS)

    Phillips, C. L.

    1973-01-01

    The results are reported of research into the effects on system operation of signal quantization in a digital control system. The investigation considered digital controllers (filters) operating in floating-point arithmetic in either open-loop or closed-loop systems. An error analysis technique is developed, and is implemented by a digital computer program that is based on a digital simulation of the system. As an output the program gives the programing form required for minimum system quantization errors (either maximum of rms errors), and the maximum and rms errors that appear in the system output for a given bit configuration. The program can be integrated into existing digital simulations of a system.

  5. Design of permanent magnet synchronous motor speed control system based on SVPWM

    NASA Astrophysics Data System (ADS)

    Wu, Haibo

    2017-04-01

    The control system is designed to realize TMS320F28335 based on the permanent magnet synchronous motor speed control system, and put it to quoting all electric of injection molding machine. The system of the control method used SVPWM, through the sampling motor current and rotating transformer position information, realize speed, current double closed loop control. Through the TMS320F28335 hardware floating-point processing core, realize the application for permanent magnet synchronous motor in the floating point arithmetic, to replace the past fixed-point algorithm, and improve the efficiency of the code.

  6. Low Cost Night Vision System for Intruder Detection

    NASA Astrophysics Data System (ADS)

    Ng, Liang S.; Yusoff, Wan Azhar Wan; R, Dhinesh; Sak, J. S.

    2016-02-01

    The growth in production of Android devices has resulted in greater functionalities as well as lower costs. This has made previously more expensive systems such as night vision affordable for more businesses and end users. We designed and implemented robust and low cost night vision systems based on red-green-blue (RGB) colour histogram for a static camera as well as a camera on an unmanned aerial vehicle (UAV), using OpenCV library on Intel compatible notebook computers, running Ubuntu Linux operating system, with less than 8GB of RAM. They were tested against human intruders under low light conditions (indoor, outdoor, night time) and were shown to have successfully detected the intruders.

  7. Evaluation of water uptake and mechanical properties of blended polymer films for preparing gas-generated multiple-unit floating drug delivery systems.

    PubMed

    Chen, Ying-Chen; Lee, Lin-Wen; Ho, Hsiu-O; Sha, Chen; Sheu, Ming-Thau

    2012-10-01

    Among various strategies of gastroretentive drug delivery systems (DDSs) developed to prolong the gastric residence time and to increase the overall bioavailability, effervescent multiple-unit floating DDSs (muFDDSs) were studied here. These systems consist of drug (losartan)- and effervescent (sodium bicarbonate)-containing pellets coated with a blended polymeric membrane, which was a mixture of gastrointestinal tract (GIT)-soluble and GIT-insoluble polymers. The addition of GIT-soluble polymers, such as hydroxypropyl methylcellulose, polyethylene glycol (PEG) 6000, PEG 600, and Kollicoat® IR, greatly increased the water uptake ability of the GIT-insoluble polymers (Eudragit® NE, RS, and RL; Surelease®; and Kollicoat® SR) and caused them to immediately initiate the effervescent reaction and float, but the hydrated films should also be impermeable to the generated CO(2) to maintain floatation and sufficiently flexible to withstand the pressure of carbon dioxide to avoid rupturing. The study demonstrated that the water uptake ability and mechanical properties could be applied as screening tools during the development of effervescent muFDDSs. The optimized system of SRT(5)P600(5) (i.e., a mixture of 5% Kollicoat® SR and 5% PEG 600) with a 20% coating level began to completely float within 15 min and maintained its buoyancy over a period of 12 h with a sustained-release effect. Copyright © 2012 Wiley Periodicals, Inc.

  8. Fate of methane in aquatic systems dominated by free-floating plants.

    PubMed

    Kosten, Sarian; Piñeiro, Marcia; de Goede, Eefje; de Klein, Jeroen; Lamers, Leon P M; Ettwig, Katharina

    2016-11-01

    Worldwide the area of free-floating plants is increasing, which can be expected to alter methane (CH 4 ) emissions from aquatic systems in several ways. A large proportion of the CH 4 produced may become oxidized below the plants due to the accumulation of CH 4 as a result of a decrease in the diffusive water-atmosphere flux and the entrapment of part of the ebullitive CH 4 , in combination with suitable conditions for methane oxidizing (MOX) bacteria in the aerobic rhizosphere. We used a set of essays to test this hypothesis and to explore the effect of different densities for three widespread free-floating species: Azolla filiculoides, Salvinia natans, and Eichhornia crassipes. The gas exchange velocity, proportion of CH 4 bubbles trapped by the plants, occurrence of radial oxygen loss from roots, and MOX rates on the roots were assessed. We subsequently used the outcome of these experiments to parameterize a simple model. With this model we estimated the proportion of the produced CH 4 that is oxidized, for different plant species and different densities. We found that in a shallow (1 m) system up to 70% of the CH 4 produced may become oxidized as a result of a strong decrease in gas exchange combined with high MOX activity of the rhizosphere microbiome. As floating plants also are likely to increase CH 4 production by organic matter production, especially when their presence induces anaerobic conditions, the overall effect on CH 4 emission will strongly depend on local conditions. This explains the contrasting effects of floating plants on CH 4 emissions in literature as reviewed here. As the effect of floating plants on CH 4 emissions, including the high MOX rates we show here, can be substantial, there is an urgent need to consider this impact when assessing greenhouse gas budgets. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Helicopter flights with night-vision goggles: Human factors aspects

    NASA Technical Reports Server (NTRS)

    Brickner, Michael S.

    1989-01-01

    Night-vision goggles (NVGs) and, in particular, the advanced, helmet-mounted Aviators Night-Vision-Imaging System (ANVIS) allows helicopter pilots to perform low-level flight at night. It consists of light intensifier tubes which amplify low-intensity ambient illumination (star and moon light) and an optical system which together produce a bright image of the scene. However, these NVGs do not turn night into day, and, while they may often provide significant advantages over unaided night flight, they may also result in visual fatigue, high workload, and safety hazards. These problems reflect both system limitations and human-factors issues. A brief description of the technical characteristics of NVGs and of human night-vision capabilities is followed by a description and analysis of specific perceptual problems which occur with the use of NVGs in flight. Some of the issues addressed include: limitations imposed by a restricted field of view; problems related to binocular rivalry; the consequences of inappropriate focusing of the eye; the effects of ambient illumination levels and of various types of terrain on image quality; difficulties in distance and slope estimation; effects of dazzling; and visual fatigue and superimposed symbology. These issues are described and analyzed in terms of their possible consequences on helicopter pilot performance. The additional influence of individual differences among pilots is emphasized. Thermal imaging systems (forward looking infrared (FLIR)) are described briefly and compared to light intensifier systems (NVGs). Many of the phenomena which are described are not readily understood. More research is required to better understand the human-factors problems created by the use of NVGs and other night-vision aids, to enhance system design, and to improve training methods and simulation techniques.

  10. Transforming Ocean Observations of the Carbon Budget, Acidification, Hypoxia, Nutrients, and Biological Productivity: a Global Array of Biogeochemical Argo Floats

    NASA Astrophysics Data System (ADS)

    Talley, L. D.; Johnson, K. S.; Claustre, H.; Boss, E.; Emerson, S. R.; Westberry, T. K.; Sarmiento, J. L.; Mazloff, M. R.; Riser, S.; Russell, J. L.

    2017-12-01

    Our ability to detect changes in biogeochemical (BGC) processes in the ocean that may be driven by increasing atmospheric CO2, as well as by natural climate variability, is greatly hindered by undersampling in vast areas of the open ocean. Argo is a major international program that measures ocean heat content and salinity with about 4000 floats distributed throughout the ocean, profiling to 2000 m every 10 days. Extending this approach to a global BGC-Argo float array, using recent, proven sensor technology, and in close synergy with satellite systems, will drive a transformative shift in observing and predicting the effects of climate change on ocean metabolism, carbon uptake, acidification, deoxygenation, and living marine resource management. BGC-Argo will add sensors for pH, oxygen, nitrate, chlorophyll, suspended particles, and downwelling irradiance, with sufficient accuracy for climate studies. Observing System Simulation Experiments (OSSEs) using BGC models indicate that 1000 BGC floats would provide sufficient coverage, hence equipping 1/4 of the Argo array. BGC-Argo (http://biogeochemical-argo.org) will enhance current sustained observational programs such as Argo, GO-SHIP, and long-term ocean time series. BGC-Argo will benefit from deployments on GO-SHIP vessels, which provide sensor verification. Empirically derived algorithms that relate the observed BGC float parameters to the carbon system parameters will provide global information on seasonal ocean-atmosphere carbon exchange. BGC Argo measurements could be paired with other emerging technology, such as pCO2 measurements from ships of opportunity and wave gliders, to extend and validate exchange estimates. BGC-Argo prototype programs already show the potential of a global observing system that can measure seasonal to decadal variability. Various countries have developed regional BGC arrays: Southern Ocean (SOCCOM), North Atlantic Subpolar Gyre (remOcean), Mediterranean (NAOS), the Kuroshio (INBOX), and Indian Ocean (IOBioArgo). As examples, bio-optical sensors are identifying regional anomalies in light attenuation/scattering, with implications for ocean productivity and carbon export; SOCCOM floats show high CO2 outgassing in the Antarctic Circumpolar Current, due to previously unmeasured winter fluxes.

  11. Floating microbial fuel cells as energy harvesters for signal transmission from natural water bodies

    NASA Astrophysics Data System (ADS)

    Schievano, Andrea; Colombo, Alessandra; Grattieri, Matteo; Trasatti, Stefano P.; Liberale, Alessandro; Tremolada, Paolo; Pino, Claudio; Cristiani, Pierangela

    2017-02-01

    A new type of floating microbial fuel cell (fMFC) was developed for power supply of remote environmental sensors and data transmission. Ten operating fMFCs generated a cell potential in the range 100-800 mV depending on the external resistance applied. Power production peaked around 3-3.5 mW (power density of 22-28 mW m-2 cathode) after about 20-30 days of start-up period. The average of daily electrical energy harvested ranged between 10 and 35 mWh/d. Long-term performances were ensured in the presence of dense rice plants (Oryza Sativa). A power management system, based on a step-up DC/DC converter and a low-power data transmission system via SIGFOX™ technology, have been set up for the fMFCs. The tested fMFCs systems allowed to: i) harvest produced energy, ii) supply electronic devices (intermittent LED-light and a buzzer); iii) transmit remote data at low speed (three message of 12 bites each, in 6 s). Several 'floating garden' MFCs were set in the context of demonstrative events at EXPO2015 world exposition held in Milan between May-October 2015. Some of the 'floating garden' MFCs were operating for more than one year.

  12. In-service tests of the effectiveness of vibration control measures on the BART rail transit system

    NASA Astrophysics Data System (ADS)

    Saurenman, Hugh

    2005-09-01

    Controlling vibration from new rail transit systems can be quite expensive when the alignment passes through residential areas. However, there is relatively little documented information on how effective different vibration mitigation approaches perform under in-service conditions. This paper presents results of a number of vibration measurements of the different track forms used on the current San Francisco Bay Area Rapid Transit (BART) system including floating slab, resiliently supported half ties, and high-resilience direct fixation fasteners in subways and one section of floating slab used on at-grade tracks. The goal was to obtain data that would improve the predictions of future vibration levels and perhaps lead to more cost effective vibration mitigation strategies for the proposed BART extension to San Jose. The tests show that the floating slabs are performing much as designed, the resiliently supported half ties are less effective than expected, and the high resilience track fasteners are probably performing as expected, although the results are clouded because of severe rail corrugation in the area where the new fasteners were installed. Some unanticipated results are the apparent interaction of the floating slab resonance, the wheel rotation frequency, the bogey dynamics, and vibration propagation characteristics of the ground.

  13. Do permanent night workers show circadian adjustment? A review based on the endogenous melatonin rhythm.

    PubMed

    Folkard, Simon

    2008-04-01

    "Permanent" or "fixed" night shifts have been argued to offer a potential benefit over rotating shift systems in that they may serve to maximize circadian adjustment and hence minimize the various health and safety problems associated with night work. For this reason, some authors have argued in favor of permanent shift systems, but their arguments assume at least a substantial, if not complete, adjustment of the circadian clock. They have emphasized the finding that the day sleeps taken between successive night shifts by permanent night workers are rather longer than those of either slowly or rapidly rotating shift workers, but this could simply reflect increased pressure for sleep. The present paper reviews the literature on the adjustment to permanent night work of the circadian rhythm in the secretion of melatonin, which is generally considered to be the best known indicator of the state of the endogenous circadian body clock. Studies of workers in "abnormal" environments, such as oil rigs and remote mining operations, were excluded, as the nature of these unique settings might serve to assist adjustment. The results of the six studies included indicate that only a very small minority (<3%) of permanent night workers evidence "complete"adjustment of their endogenous melatonin rhythm to night work, less than one in four permanent night workers evidence sufficiently "substantial" adjustment to derive any benefit from it, there is no difference between studies conducted in normal or dim lighting, and there is no evidence of gender difference in the adjustment to permanent night work. It is concluded that in normal environments, permanent night-shift systems are unlikely to result in sufficient circadian adjustment in most individuals to benefit health and safety.

  14. Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes.

    PubMed

    Spaic, Tamara; Driscoll, Marsha; Raghinaru, Dan; Buckingham, Bruce A; Wilson, Darrell M; Clinton, Paula; Chase, H Peter; Maahs, David M; Forlenza, Gregory P; Jost, Emily; Hramiak, Irene; Paul, Terri; Bequette, B Wayne; Cameron, Faye; Beck, Roy W; Kollman, Craig; Lum, John W; Ly, Trang T

    2017-03-01

    The objective of this study was to determine the safety, feasibility, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system compared with predictive low-glucose insulin suspension (PLGS) alone in overnight glucose control. A 42-night trial was conducted in 30 individuals with type 1 diabetes in the age range 15-45 years. Participants were randomly assigned each night to either PHHM or PLGS and were blinded to the assignment. The system suspended the insulin pump on both the PHHM and PLGS nights for predicted hypoglycemia but delivered correction boluses for predicted hyperglycemia on PHHM nights only. The primary outcome was the percentage of time spent in a sensor glucose range of 70-180 mg/dL during the overnight period. The addition of automated insulin delivery with PHHM increased the time spent in the target range (70-180 mg/dL) from 71 ± 10% during PLGS nights to 78 ± 10% during PHHM nights ( P < 0.001). The average morning blood glucose concentration improved from 163 ± 23 mg/dL after PLGS nights to 142 ± 18 mg/dL after PHHM nights ( P < 0.001). Various sensor-measured hypoglycemic outcomes were similar on PLGS and PHHM nights. All participants completed 42 nights with no episodes of severe hypoglycemia, diabetic ketoacidosis, or other study- or device-related adverse events. The addition of a predictive hyperglycemia minimization component to our existing PLGS system was shown to be safe, feasible, and effective in overnight glucose control. © 2017 by the American Diabetes Association.

  15. Night-time neuronal activation of Cluster N in a day- and night-migrating songbird.

    PubMed

    Zapka, Manuela; Heyers, Dominik; Liedvogel, Miriam; Jarvis, Erich D; Mouritsen, Henrik

    2010-08-01

    Magnetic compass orientation in a night-migratory songbird requires that Cluster N, a cluster of forebrain regions, is functional. Cluster N, which receives input from the eyes via the thalamofugal pathway, shows high neuronal activity in night-migrants performing magnetic compass-guided behaviour at night, whereas no activation is observed during the day, and covering up the birds' eyes strongly reduces neuronal activation. These findings suggest that Cluster N processes light-dependent magnetic compass information in night-migrating songbirds. The aim of this study was to test if Cluster N is active during daytime migration. We used behavioural molecular mapping based on ZENK activation to investigate if Cluster N is active in the meadow pipit (Anthus pratensis), a day- and night-migratory species. We found that Cluster N of meadow pipits shows high neuronal activity under dim-light at night, but not under full room-light conditions during the day. These data suggest that, in day- and night-migratory meadow pipits, the light-dependent magnetic compass, which requires an active Cluster N, may only be used during night-time, whereas another magnetosensory mechanism and/or other reference system(s), like the sun or polarized light, may be used as primary orientation cues during the day.

  16. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    PubMed

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  17. Floating production platforms and their applications in the development of oil and gas fields in the South China Sea

    NASA Astrophysics Data System (ADS)

    Zhang, Dagang; Chen, Yongjun; Zhang, Tianyu

    2014-03-01

    This paper studies the current available options for floating production platforms in developing deepwater oil fields and the potential development models of future oil and gas exploration in the South China Sea. A detailed review of current deepwater platforms worldwide was performed through the examples of industry projects, and the pros and cons of each platform are discussed. Four types of platforms are currently used for the deepwater development: tension leg platform, Spar, semi-submersible platform, and the floating production system offloading. Among these, the TLP and Spar can be used for dry tree applications, and have gained popularity in recent years. The dry tree application enables the extension of the drilling application for fixed platforms into floating systems, and greatly reduces the cost and complexity of the subsea operation. Newly built wet tree semi-submersible production platforms for ultra deepwater are also getting their application, mainly due to the much needed payload for deepwater making the conversion of the old drilling semi-submersible platforms impossible. These platforms have been used in different fields around the world for different environments; each has its own advantages and disadvantages. There are many challenges with the successful use of these floating platforms. A lot of lessons have been learned and extensive experience accumulated through the many project applications. Key technologies are being reviewed for the successful use of floating platforms for field development, and potential future development needs are being discussed. Some of the technologies and experience of platform applications can be well used for the development of the South China Sea oil and gas field.

  18. Moulded infrared optics making night vision for cars within reach

    NASA Astrophysics Data System (ADS)

    Bourget, Antoine; Guimond, Yann; Franks, John; Van Den Bergh, Marleen

    2005-02-01

    Sustainable mobility is a major public concern, making increased safety one of the major challenges for the car of the future. About half of all serious traffic accidents occur at night, while only a minority of journeys is at night. Reduced visibility is one of the main reasons for these striking statistics and this explains the interest of the automobile industry in Enhanced Night Vision Systems. As an answer to the need for high volume, low cost optics for these applications, Umicore has developed GASIR. This material is transparent in the NEAR and FAR infrared, and is mouldable into high quality finished spherical, aspherical and diffractive lenses. Umicore's GASIR moulded lenses are an ideal solution for thermal imaging for cars (Night Vision) and for sensing systems like pedestrian detection, collision avoidance, occupation detection, intelligent airbag systems etc.

  19. Night vision: requirements and possible roadmap for FIR and NIR systems

    NASA Astrophysics Data System (ADS)

    Källhammer, Jan-Erik

    2006-04-01

    A night vision system must increase visibility in situations where only low beam headlights can be used today. As pedestrians and animals have the highest risk increase in night time traffic due to darkness, the ability of detecting those objects should be the main performance criteria, and the system must remain effective when facing the headlights of oncoming vehicles. Far infrared system has been shown to be superior to near infrared system in terms of pedestrian detection distance. Near infrared images were rated to have significantly higher visual clutter compared with far infrared images. Visual clutter has been shown to correlate with reduction in detection distance of pedestrians. Far infrared images are perceived as being more unusual and therefore more difficult to interpret, although the image appearance is likely related to the lower visual clutter. However, the main issue comparing the two technologies should be how well they solve the driver's problem with insufficient visibility under low beam conditions, especially of pedestrians and other vulnerable road users. With the addition of an automatic detection aid, a main issue will be whether the advantage of FIR systems will vanish given NIR systems with well performing automatic pedestrian detection functionality. The first night vision introductions did not generate the sales volumes initially expected. A renewed interest in night vision systems are however to be expected after the release of night vision systems by BMW, Mercedes and Honda, the latter with automatic pedestrian detection.

  20. MS Ivins floats through U.S. Laboratory / Destiny module

    NASA Image and Video Library

    2001-02-11

    STS98-E-5161 (11 February 2001) --- Astronaut Marsha S. Ivins, STS-98 mission specialist, floats into the newly attached Destiny laboratory onboard the International Space Station (ISS). After the Destiny hatch was opened early in the day, members of both crews went to work quickly inside the new module, activating air systems, fire extinguishers, alarm systems, computers and internal communications. The crews also took some photos and continued equipment transfers from the shuttle to the station. The scene was taken with a digital still camera.

  1. Cross-sectional study on their reproductive health status of 604 female floating residents in Beijing.

    PubMed

    Wang, Y; An, L; Zhang, X B; Wang, S X

    1999-03-01

    The rapid increases in the numbers of female labor migrants ("floating residents") in cities such as Beijing have created challenges for China's reproductive health care system. An exploratory study conducted in Beijing in 1996 of 507 floating workers engaged in household management work (average age, 27.4 years) sought to gain information to facilitate the design of reproductive health services for this group. The women had resided in Beijing for an average of 3.7 years, generally with their families. 84% were married, at a mean age of 21.87 years; married women had an average of 1.43 live births, 42% of which had occurred in Beijing. 25% did not receive any prenatal care and 60% did not know whom to consult about maternal-child health care problems. Contraceptive prevalence was 81.1% among floating workers compared with 97% among a comparison group of nonmigrant agricultural and textile workers. Most floating workers were unaware of any contraceptive methods other than the one they were using (generally the IUD or female sterilization). Finally, only 8.4% could cite symptoms of sexually transmitted diseases and 33.9% had not heard of AIDS. Laboratory examinations revealed a 29.3% prevalence of reproductive tract infections among female floating residents. bacterial vaginitis (11.6%) and Mycoplasma infection (6.7%) were most prevalent. These findings confirm that female floating residents remain in Beijing a long time and have a serious unmet need for targeted reproductive health care services.

  2. Design and in vitro/in vivo evaluation of sustained-release floating tablets of itopride hydrochloride

    PubMed Central

    Ahmed, Sayed M; Ahmed Ali, Adel; Ali, Ahmed MA; Hassan, Omiya A

    2016-01-01

    Purpose The aim of the present study was to improve the bioavailability of itopride (ITO) and sustain its action by formulating as a floating dosage form. Materials and methods Sustained-release floating tablets of ITO hydrochloride (HCl) were prepared by direct compression using different hydrocolloid polymers such as hydroxypropyl methylcellulose and ethylcellulose and/or methacrylic acid polymers Eudragit RSPM and Carbopol 934P. The floating property was achieved using an effervescent mixture of sodium bicarbonate and anhydrous citric acid (1:1 mol/mol). Hardness, friability, content uniformity, and dissolution rate of the prepared floating tablets were evaluated. The formulation F10 composed of 28.5% Eudragit RSPM, 3% NaHCO3, and 7% citric acid provided sustained drug release. Results In vitro results showed sustained release of F10 where the drug release percentage was 96.51%±1.75% after 24 hours (P=0.031). The pharmacokinetic results indicated that the area under the curve (AUC0–∞) of the prepared sustained-release floating tablets at infinity achieved 93.69 µg·h/mL compared to 49.89 µg·h/mL for the reference formulation (Ganaton®) and the relative bioavailability of the sustained-release formulation F10 increased to 187.80% (P=0.022). Conclusion The prepared floating tablets of ITO HCl (F10) could be a promising drug delivery system with sustained-release action and enhanced drug bioavailability. PMID:28008229

  3. Ergodicity of Traffic Flow with Constant Penetration Rate for Traffic Monitoring via Floating Vehicle Technique

    NASA Astrophysics Data System (ADS)

    Gunawan, Fergyanto E.; Abbas, Bahtiar S.; Atmadja, Wiedjaja; Yoseph Chandra, Fajar; Agung, Alexander AS; Kusnandar, Erwin

    2014-03-01

    Traffic congestion in Asian megacities has become extremely worse, and any means to lessen the congestion level is urgently needed. Building an efficient mass transportation system is clearly necessary. However, implementing Intelligent Transportation Systems (ITS) have also been demonstrated effective in various advanced countries. Recently, the floating vehicle technique (FVT), an ITS implementation, has become cost effective to provide real-time traffic information with proliferation of the smartphones. Although many publications have discussed various issues related to the technique, none of them elaborates the discrepancy of a single floating car data (FCD) and the associated fleet data. This work addresses the issue based on an analysis of Sugiyama et al's experimental data. The results indicate that there is an optimum averaging time interval such that the estimated velocity by the FVT reasonably representing the traffic velocity.

  4. PePSS - A portable sky scanner for measuring extremely low night-sky brightness

    NASA Astrophysics Data System (ADS)

    Kocifaj, Miroslav; Kómar, Ladislav; Kundracik, František

    2018-05-01

    A new portable sky scanner designed for low-light-level detection at night is developed and employed in night sky brightness measurements in a rural region. The fast readout, adjustable sensitivity and linear response guaranteed in 5-6 orders of magnitude makes the device well suited for narrow-band photometry in both dark areas and bright urban and suburban environments. Quasi-monochromatic night-sky brightness data are advantageous in the accurate characterization of spectral power distribution of scattered and emitted light and, also allows for the possibility to retrieve light output patterns from whole-city light sources. The sky scanner can operate in both night and day regimes, taking advantage of the complementarity of both radiance data types. Due to its inherent very high sensitivity the photomultiplier tube could be used in night sky radiometry, while the spectrometer-equipped system component capable of detecting elevated intensities is used in daylight monitoring. Daylight is a source of information on atmospheric optical properties that in turn are necessary in processing night sky radiances. We believe that the sky scanner has the potential to revolutionize night-sky monitoring systems.

  5. Multiple sleep bruxism data collected using a self-contained EMG detector/analyzer system in asymptomatic healthy subjects.

    PubMed

    Minakuchi, Hajime; Sakaguchi, Chiyomi; Hara, Emilio S; Maekawa, Kenji; Matsuka, Yoshizo; Clark, Glenn T; Kuboki, Takuo

    2012-12-01

    Small, self-contained electromyographic (EMG) detector/analyzer (D/A) devices have become available for the detection of jaw muscle activity events above threshold. These devices claim to be less intrusive to the subjects sleep so it is less prone to induce disturbed sleep. The objective of this study was to evaluate for night-to-night variability and examine for a systematic alteration on the first night in EMG levels. Ten asymptomatic healthy volunteers (mean age, 26.8 ± 3.78) were recorded for six sequential nights in their home environment using EMG D/A system. The device yields a nightly EMG level above threshold score on a 0-4 level. Because the data are categorical and nonparametric, the data of the ten subjects across six nights were submitted to a Friedman repeated measures ANOVA. The significant level was set as alpha equal to 0.05. The median and mode values of the subjects were tabulated and analyzed and we did not find a significant difference in EMG D/A level across the six nights (p = 0.287, Kendall's coefficient of concordance = 0.124, Friedman two-way repeated measures ANOVA). The data did show clear and substantial night-to-night variability. Substantial night-to-night variability in masseter EMG activity levels was clearly observed in our subjects. There was no evidence of a suppressed or elevated first-night effect-like variability on masseter muscle EMG level seen in these subjects using a small portable self-contained EMG detector/analyzer. These data suggest that recordings should be at least 5-6-nights duration to establish a reasonable measure of an individual's average nightly masseter EMG level.

  6. A New Nightly Build System for LHCb

    NASA Astrophysics Data System (ADS)

    Clemencic, M.; Couturier, B.

    2014-06-01

    The nightly build system used so far by LHCb has been implemented as an extension of the system developed by CERN PH/SFT group (as presented at CHEP2010). Although this version has been working for many years, it has several limitations in terms of extensibility, management and ease of use, so that it was decided to develop a new version based on a continuous integration system. In this paper we describe a new implementation of the LHCb Nightly Build System based on the open source continuous integration system Jenkins and report on the experience of configuring a complex build workflow in Jenkins.

  7. Auto-flotation of heterocyst enables the efficient production of renewable energy in cyanobacteria

    PubMed Central

    Chen, Ming; Li, Jihong; Zhang, Lei; Chang, Sandra; Liu, Chen; Wang, Jianlong; Li, Shizhong

    2014-01-01

    Utilizing cyanobacteria as a bioenergy resource is difficult due to the cost and energy consuming harvests of microalgal biomass. In this study, an auto-floating system was developed by increasing the photobiological H2 production in the heterocysts of filamentous cyanobacteria. An amount of 1.0 μM of diuron, which inhibited O2 production in cyanobacteria, resulted in a high rate of H2 production in heterocysts. The auto-floating process recovered 91.71% ± 1.22 of the accumulated microalgal biomass from the liquid media. Quantification analysis revealed that 0.72–1.10 μmol H2 per mg dry weight microalgal biomass was necessary to create this auto-floating system. Further bio-conversion by using anaerobic digestion converted the harvested microalgal biomass into biogas. Through this novel coupled system of photobiological H2 production and anaerobic digestion, a high level of light energy conversion efficiency from solar energy to bioenergy was attained with the values of 3.79% ± 0.76. PMID:24499777

  8. Auto-flotation of heterocyst enables the efficient production of renewable energy in cyanobacteria.

    PubMed

    Chen, Ming; Li, Jihong; Zhang, Lei; Chang, Sandra; Liu, Chen; Wang, Jianlong; Li, Shizhong

    2014-02-06

    Utilizing cyanobacteria as a bioenergy resource is difficult due to the cost and energy consuming harvests of microalgal biomass. In this study, an auto-floating system was developed by increasing the photobiological H2 production in the heterocysts of filamentous cyanobacteria. An amount of 1.0 μM of diuron, which inhibited O2 production in cyanobacteria, resulted in a high rate of H2 production in heterocysts. The auto-floating process recovered 91.71% ± 1.22 of the accumulated microalgal biomass from the liquid media. Quantification analysis revealed that 0.72-1.10 μmol H2 per mg dry weight microalgal biomass was necessary to create this auto-floating system. Further bio-conversion by using anaerobic digestion converted the harvested microalgal biomass into biogas. Through this novel coupled system of photobiological H2 production and anaerobic digestion, a high level of light energy conversion efficiency from solar energy to bioenergy was attained with the values of 3.79% ± 0.76.

  9. STS-46 MS PLC Hoffman floats in life raft during water egress training at JSC

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, Mission Specialist (MS) and Payload Commander Jeffrey A. Hoffman floats in a one-person life raft during launch emergency egress (bailout) simulation conducted in JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. Hoffman, who has just tumbled out a side hatch mockup, waits for his life raft to fully inflate as a SCUBA-equipped diver looks on. The long cylindrical object in the foreground serves as a prop for the crew escape system (CES) pole. In the background MS Franklin R. Chang-Diaz floats in a fully inflated life raft.

  10. Biting midges (Diptera: Ceratopogonidae) from Martín García Island, Argentina.

    PubMed

    Ronderos, María M; Marino, Pablo I; Díaz, Florentina; Estévez, Ana L

    2011-09-01

    Nearly 230 species of biting midges have been recorded or described from Argentina; 38 of them are known from the Buenos Aires province and only one is cited from Martín García Island. This paper presents the results raised from six collecting trips which took place on the island during spring 2005, summer 2006 and autumn 2009. Diverse sampling sites including permanent and temporary aquatic environments were chosen, most of the ten sampling sites were ponds of diverse origin, some of these environments were covered with floating vegetation as Lemna gibba, Lemna minuscule, Salvinia biloba, Salvinia minima, Azolla filiculoides, Limnobium laevigatum, Pistia stratiotes, Spirodela intermedia, Wolffiella oblonga and Wolffia columbiana. Other sites were placed in urban and suburban areas. Adults were collected with sweep nets at sunrise and sunset and with light traps at intervals of four to five hours at night, depending on electricity availability on the island. Larvae and pupae were collected with different implements depending on characteristics of each surveyed aquatic habitat. In free standing water, they were captured with small sieves or hand pipettes and micropipettes, flotation techniques were utilized for sampling vegetated areas, free and rooted floating hydrophytes were extracted for removing insects among them. Thirteen species of Ceratopogonidae were collected, three of Atrichopogon Kieffer, three of Forcipomyia Meigen, two of Dasyhelea Kieffer, four of Culicoides Latreille, and one of Bezzia Kieffer, all representing new records from the island.

  11. Hybrid display of static image and aerial image by use of transparent acrylic cubes and retro-reflectors

    NASA Astrophysics Data System (ADS)

    Morita, Shogo; Ito, Shusei; Yamamoto, Hirotsugu

    2017-02-01

    Aerial display can form transparent floating screen in the mid-air and expected to provide aerial floating signage. We have proposed aerial imaging by retro-reflection (AIRR) to form a large aerial LED screen. However, luminance of aerial image is not sufficiently high so as to be used for signage under broad daylight. The purpose of this paper is to propose a novel aerial display scheme that features hybrid display of two different types of images. Under daylight, signs made of cubes are visible. At night, or under dark lighting situation, aerial LED signs become visible. Our proposed hybrid display is composed of an LED sign, a beam splitter, retro-reflectors, and transparent acrylic cubes. Aerial LED sign is formed with AIRR. Furthermore, we place transparent acrylic cubes on the beam splitter. Light from the LED sign enters transparent acrylic cubes, reflects twice in the transparent acrylic cubes, exit and converge to planesymmetrical position with light source regarding the cube array. Thus, transparent acrylic cubes also form the real image of the source LED sign. Now, we form a sign with the transparent acrylic cubes so that this cube-based sign is apparent under daylight. We have developed a proto-type display by use of 1-cm transparent cubes and retro-reflective sheeting and successfully confirmed aerial image forming with AIRR and transparent cubes as well as cube-based sign under daylight.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szluha, A.; Morrison, A.; Heckman, C.

    Physico-chemical criteria were established and subjected to the chemical compounds listed in CHRIS to select those chemicals which are immiscible and float on water. This information was compiled in a menu-driven data base for easy access. As the result of this work, 294 CHRIS chemicals were found to be floaters. A literature review was conducted also to review available spill containment and recovery equipment and techniques for the application toward floating hazardous chemical spills. No single technology or equipment was found to effectively apply for the containment and recovery of spilled floating chemicals. Specific deficiencies and problems inherent in existingmore » technologies were identified. A hazard and toxicity ranking system was developed and applied to the floating chemicals for groupings by degrees of flammability and toxicity hazards. These groupings include highly flammable through noncombustible and highly toxic through non-toxic and the combination of degrees of hazards.« less

  13. A Flexible VHDL Floating Point Module for Control Algorithm Implementation in Space Applications

    NASA Astrophysics Data System (ADS)

    Padierna, A.; Nicoleau, C.; Sanchez, J.; Hidalgo, I.; Elvira, S.

    2012-08-01

    The implementation of control loops for space applications is an area with great potential. However, the characteristics of this kind of systems, such as its wide dynamic range of numeric values, make inadequate the use of fixed-point algorithms.However, because the generic chips available for the treatment of floating point data are, in general, not qualified to operate in space environments and the possibility of using an IP module in a FPGA/ASIC qualified for space is not viable due to the low amount of logic cells available for these type of devices, it is necessary to find a viable alternative.For these reasons, in this paper a VHDL Floating Point Module is presented. This proposal allows the design and execution of floating point algorithms with acceptable occupancy to be implemented in FPGAs/ASICs qualified for space environments.

  14. A study of rotor and platform design trade-offs for large-scale floating vertical axis wind turbines

    NASA Astrophysics Data System (ADS)

    Griffith, D. Todd; Paquette, Joshua; Barone, Matthew; Goupee, Andrew J.; Fowler, Matthew J.; Bull, Diana; Owens, Brian

    2016-09-01

    Vertical axis wind turbines are receiving significant attention for offshore siting. In general, offshore wind offers proximity to large populations centers, a vast & more consistent wind resource, and a scale-up opportunity, to name a few beneficial characteristics. On the other hand, offshore wind suffers from high levelized cost of energy (LCOE) and in particular high balance of system (BoS) costs owing to accessibility challenges and limited project experience. To address these challenges associated with offshore wind, Sandia National Laboratories is researching large-scale (MW class) offshore floating vertical axis wind turbines (VAWTs). The motivation for this work is that floating VAWTs are a potential transformative technology solution to reduce offshore wind LCOE in deep-water locations. This paper explores performance and cost trade-offs within the design space for floating VAWTs between the configurations for the rotor and platform.

  15. The Application of a Cylindrical-spherical Floating Ring Bearing as a Device to Control Stability of Turbogenerators

    NASA Technical Reports Server (NTRS)

    Leung, P. S.; Craighead, I. A.; Wilkinson, T. S.

    1991-01-01

    The development of a new device to control stability of turbogenerators is described. The device comprises a floating ring installed between the journal and bearing housing of a fluid film bearing. The journal and the inner surface of the ring are cylindrical while the outer surface of the ring and bearing surface are spherical providing axial location of the ring and self-alignment of the bearing. The employment of this device would lead to a consistent machine performance. System stability may be controlled by changing a number of bearing and floating ring parameters. This device also offers an additional advantage of having a very low frictional characteristic. A feasibility study was carried out to investigate the suitability of the new device to turbogenerator applications. Both theoretical analysis and experimental observations were carried out. Initial results suggest that the new floating ring device is a competitive alternative to other conventional arrangements.

  16. Wall shear stress measurements using a new transducer

    NASA Technical Reports Server (NTRS)

    Vakili, A. D.; Wu, J. M.; Lawing, P. L.

    1986-01-01

    A new instrument has been developed for direct measurement of wall shear stress. This instrument is simple and symmetric in design with small moving mass and no internal friction. Features employed in the design of this instrument eliminate most of the difficulties associated with the traditional floating element balances. Vibration problems associated with the floating element skin friction balances have been found to be minimized by the design features and optional damping provided. The unique design of this instrument eliminates or reduces the errors associated with conventional floating-element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Measurement made in three different tunnels show good agreement with theory and data obtained by the floating element devices.

  17. Clarithromycin highly-loaded gastro-floating fine granules prepared by high-shear melt granulation can enhance the efficacy of Helicobacter pylori eradication.

    PubMed

    Aoki, Hajime; Iwao, Yasunori; Mizoguchi, Midori; Noguchi, Shuji; Itai, Shigeru

    2015-05-01

    In an effort to develop a new gastro-retentive drug delivery system (GRDDS) without a large amount of additives, 75% clarithromycin (CAM) loaded fine granules were prepared with three different hydrophobic binders by high-shear melt granulation and their properties were evaluated. Granules containing the higher hydrophobic binder showed sustained drug release and were able to float over 24h. The synchrotron X-ray CT measurement indicated that both the high hydrophobicity of the binder and the void space inside the granules might be involved in their buoyancy. In an in vivo experiment, the floating granules more effectively eradicated Helicobacter pylori than a CAM suspension by remaining in the stomach for a longer period. In short, CAM highly-loaded gastro-floating fine granules can enhance the eradication efficiency of H. pylori compared with CAM alone. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Quantifying Thin Mat Floating Marsh Strength and Interaction with Hydrodynamic Conditions

    NASA Astrophysics Data System (ADS)

    Collins, J. H., III; Sasser, C.; Willson, C. S.

    2016-12-01

    Louisiana possesses over 350,000 acres of unique floating vegetated systems known as floating marshes or flotants. Floating marshes make up 70% of the Terrebonne and Barataria basin wetlands and exist in several forms, mainly thick mat or thin mat. Salt-water intrusion, nutria grazing, and high-energy wave events are believed to be some contributing factors to the degradation of floating marshes; however, there has been little investigation into the hydrodynamic effects on their structural integrity. Due to their unique nature, floating marshes could be susceptible to changes in the hydrodynamic environment that may result from proposed river freshwater and sediment diversion projects introducing flow to areas that are typically somewhat isolated. This study aims to improve the understanding of how thin mat floating marshes respond to increased hydrodynamic stresses and, more specifically, how higher water velocities might increase the washout probability of this vegetation type. There are two major components of this research: 1) A thorough measurement of the material properties of the vegetative mats as a root-soil matrix composite material; and 2) An accurate numerical simulation of the hydrodynamics and forces imposed on the floating marsh mats by the flow. To achieve these goals, laboratory and field experiments were conducted using a customized device to measure the bulk properties of typical floating marshes. Additionally, Delft-3D FLOW and ANSYS FLUENT were used to simulate the flow around a series of simplified mat structures in order to estimate the hydrodynamic forcings on the mats. The hydrodynamic forcings are coupled with a material analysis, allowing for a thorough analysis of their interaction under various conditions. The 2-way Fluid Structure Interaction (F.S.I.) between the flow and the mat is achieved by coupling a Finite Element Analysis (F.E.A.) solver in ANSYS with FLUENT. The flow conditions necessary for the structural failure of the floating marshes are determined for a multitude of mat shapes and sizes, leading to a quantifiable critical velocity required for washout. Ultimately, through dimensional analysis, an equation for washout potential will be developed from the results, which could be used as a design guideline.

  19. The Burden of Burnout.

    PubMed

    Elmariah, Hany; Thomas, Samantha; Boggan, Joel C; Zaas, Aimee; Bae, Jonathan

    This study sought to determine burnout prevalence and factors associated with burnout in internal medicine residents after introduction of the 2011 ACGME duty hour rules. Burnout was evaluated using an anonymized, abbreviated version of the Maslach Burnout Inventory. Surveys were collected biweekly for 48 weeks during the 2013-2014 academic year. Burnout severity was compared across subgroups and time. A score of 3 or higher signified burnout. Overall, 944 of 3936 (24%) surveys were completed. The mean burnout score across all surveys was 2.8. Categorical residents had higher burnout severity than noncategorical residents (2.9 vs 2.7, P = .005). Postgraduate year 2 residents had the highest burnout severity by year (3.1, P < .001). Residents on inpatient rotations had higher burnout severity than residents on outpatient or consultation rotations (3.1 vs 2.2 vs 2.2, P < .001). Night float rotations had the highest severity (3.8). Burnout remains a significant problem even with recent duty hour modifications.

  20. Managing and mitigating fatigue in the era of changing resident duty hours

    PubMed Central

    2014-01-01

    The medical establishment is grappling with the complex issue of duty hour regulations – an issue that is a natural consequence of the numerous changes in medical culture and practice that have occurred over the course of decades. Sleep deprivation resulting from long duty hours has a recognized impact on resident health and wellness. This paper will briefly outline the evolution of the concept of well-being in residency, review the specific theme of fatigue management within that context, and describe strategies that may be used to mitigate and manage fatigue, as well as approaches that may be taken to adapt to new scheduling models such as night float. Finally, the paper will call for a change in the culture in our workplaces and among our residents and faculty to one that promotes good health and ensures that we maintain a fit and sustainable medical workforce. PMID:25558784

  1. 76 FR 71322 - Taking and Importing Marine Mammals; U.S. Navy Training in the Hawaii Range Complex

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-17

    ..., most operationally sound method of initiating a demolition charge on a floating mine or mine at depth...; require building/ deploying an improvised, bulky, floating system for the receiver; and add another 180 ft... charge initiating device are taken to the detonation point. Military forms of C-4 are used as the...

  2. STS-26 Pilot Covey floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Pilot Richard O. Covey, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle.

  3. The Impact of Onboard Maintenance Training on Surface Ship Readiness.

    DTIC Science & Technology

    1987-12-01

    receives the majority of formal shipboard training time and resources. Watchstander training is managed through the t theory , systems, and watch...ASS :F(LSHIP.EQ .1.OR.LGE(CSHIP(NCASRP+1),CLASS(N4CLASS41)))THEN DO 795 J=1,NEIC IF(ITOTTM1(1 ,J) UGT 0)THEN FAILI’FLOAT(ITOTAL(1,J))/FLOAT(ITOTTM(1,J

  4. Borofloat and Starphire Float Glasses: A Comparison

    DOE PAGES

    Wereszczak, Andrew A.; Anderson Jr., Charles E.

    2014-10-28

    Borofloat ® borosilicate float glass and Starphire ® soda-lime silicate float glass are used in transparent protective systems. They are known to respond differently in some ballistic and triaxial loading conditions, and efforts are underway to understand the causes of those differences. Toward that, a suite of test and material characterizations were completed in the present study on both glasses so to identify what differences exist among them. Compositional, physical properties, elastic properties, flaw size distributions and concentrations, tensile/flexure strength, fracture toughness, spherical indentation and hardness, transmission electron microscopy, striae, high pressure responses via diamond anvil cell testing, laser shockmore » differences, and internal porosity were examined. Differences between these two float glasses were identified for many of these properties and characteristics, and the role of three (striae, high pressures where permanent densification can initiate, and sub-micron-sized porosity) lack understanding and deserve further attention. Lastly, the contributing roles of any of those properties or characteristics to triaxial or ballistic loading responses are not definitive; however, they provide potential correlations that may lead to improved understanding and management of loading responses in glasses used in transparent protective systems.« less

  5. Nutrient removal of a floating plant system receiving low- pollution wastewater: Effects of plant species and influent concentration

    NASA Astrophysics Data System (ADS)

    Duan, J. J.; Zhao, J. N.; Xue, L. H.; Yang, L. Z.

    2016-08-01

    Plant floating bed was adopted in this study to compare the purification effect of four plant species (Oenanthe javanica, Ipomoea aquatica, Hydrocotyle vulgaris, and Iris sibirica) receiving high and low treated domestic sewage. The experiment was conducted for eight months during the low temperature season. The results indicated that the average removal rates of TN and NH4+-N in I. aquatica floating bed were relatively high both under high and low influent concentration during the first stage of the experiment. During the second stage, H. vulgaris showed the best performance for nitrogen treatment, and the average removal rates of TN were 70.7% and 87.7% under high and low influent concentration, while the average removal rates of NH4 +-N were as high as 98.9% and 98.9%, accordingly. Moreover, H. vulgaris contributed most for plant assimilation to nitrogen removal among different plant floating systems. It was also found that the existence of hydrophytes effectively controlled the rise of water pH value and algae growth and reproduction, which helped to improve the aquatic environment. The results provide engineering parameters for the future design of an ecological remediation technology for low-pollution wastewater purification.

  6. Invasive floating macrophytes reduce greenhouse gas emissions from a small tropical lake

    PubMed Central

    Attermeyer, K.; Flury, S.; Jayakumar, R.; Fiener, P.; Steger, K.; Arya, V.; Wilken, F.; van Geldern, R.; Premke, K.

    2016-01-01

    Floating macrophytes, including water hyacinth (Eichhornia crassipes), are dominant invasive organisms in tropical aquatic systems, and they may play an important role in modifying the gas exchange between water and the atmosphere. However, these systems are underrepresented in global datasets of greenhouse gas (GHG) emissions. This study investigated the carbon (C) turnover and GHG emissions from a small (0.6 km2) water-harvesting lake in South India and analysed the effect of floating macrophytes on these emissions. We measured carbon dioxide (CO2) and methane (CH4) emissions with gas chambers in the field as well as water C mineralization rates and physicochemical variables in both the open water and in water within stands of water hyacinths. The CO2 and CH4 emissions from areas covered by water hyacinths were reduced by 57% compared with that of open water. However, the C mineralization rates were not significantly different in the water between the two areas. We conclude that the increased invasion of water hyacinths and other floating macrophytes has the potential to change GHG emissions, a process that might be relevant in regional C budgets. PMID:26846590

  7. Invasive floating macrophytes reduce greenhouse gas emissions from a small tropical lake

    NASA Astrophysics Data System (ADS)

    Attermeyer, K.; Flury, S.; Jayakumar, R.; Fiener, P.; Steger, K.; Arya, V.; Wilken, F.; van Geldern, R.; Premke, K.

    2016-02-01

    Floating macrophytes, including water hyacinth (Eichhornia crassipes), are dominant invasive organisms in tropical aquatic systems, and they may play an important role in modifying the gas exchange between water and the atmosphere. However, these systems are underrepresented in global datasets of greenhouse gas (GHG) emissions. This study investigated the carbon (C) turnover and GHG emissions from a small (0.6 km2) water-harvesting lake in South India and analysed the effect of floating macrophytes on these emissions. We measured carbon dioxide (CO2) and methane (CH4) emissions with gas chambers in the field as well as water C mineralization rates and physicochemical variables in both the open water and in water within stands of water hyacinths. The CO2 and CH4 emissions from areas covered by water hyacinths were reduced by 57% compared with that of open water. However, the C mineralization rates were not significantly different in the water between the two areas. We conclude that the increased invasion of water hyacinths and other floating macrophytes has the potential to change GHG emissions, a process that might be relevant in regional C budgets.

  8. Formulation and evaluation of gastroretentive microballoons containing baclofen for a floating oral controlled drug delivery system.

    PubMed

    Dube, T S; Ranpise, N S; Ranade, A N

    2014-01-01

    The objective of the present study was to fabricate and evaluate a multiparticulate oral gastroretentive dosage form of baclofen characterized by a central large cavity (hollow core) promoting unmitigated floatation with practical applications to alleviate the signs and symptoms of spasticity and muscular rigidity. Solvent diffusion and evaporation procedure were applied to prepare floating microspheres with a central large cavity using various combinations of ethylcellulose (release retardant) and HPMC K4M (release modifier) dissolved in a mixture of dichloromethane and methanol (2:1). The obtained microspheres (700-1000 µm) exhibit excellent floating ability (86 ± 2.00%) and release characteristics with entrapment efficiency of 95.2 ± 0.32%. Microspheres fabricated with ethylcellulose to HPMC K4M in the ratio 8.5:1.5 released 98.67% of the entrapped drug in 12 h. Muscle relaxation caused by baclofen microspheres impairs the rotarod performance for more than 12 h. Abdominal X-ray images showed that the gastroretention period of the floating barium sulfate- labeled microspheres was no less than 10 h. The buoyant baclofen microspheres provide a promising gastroretentive drug delivery system to deliver baclofen in spastic patients with a sustained release rate.

  9. A randomized trial of a home system to reduce nocturnal hypoglycemia in type 1 diabetes.

    PubMed

    Maahs, David M; Calhoun, Peter; Buckingham, Bruce A; Chase, H Peter; Hramiak, Irene; Lum, John; Cameron, Fraser; Bequette, B Wayne; Aye, Tandy; Paul, Terri; Slover, Robert; Wadwa, R Paul; Wilson, Darrell M; Kollman, Craig; Beck, Roy W

    2014-07-01

    Overnight hypoglycemia occurs frequently in individuals with type 1 diabetes and can result in loss of consciousness, seizure, or even death. We conducted an in-home randomized trial to determine whether nocturnal hypoglycemia could be safely reduced by temporarily suspending pump insulin delivery when hypoglycemia was predicted by an algorithm based on continuous glucose monitoring (CGM) glucose levels. Following an initial run-in phase, a 42-night trial was conducted in 45 individuals aged 15-45 years with type 1 diabetes in which each night was assigned randomly to either having the predictive low-glucose suspend system active (intervention night) or inactive (control night). The primary outcome was the proportion of nights in which ≥1 CGM glucose values ≤60 mg/dL occurred. Overnight hypoglycemia with at least one CGM value ≤60 mg/dL occurred on 196 of 942 (21%) intervention nights versus 322 of 970 (33%) control nights (odds ratio 0.52 [95% CI 0.43-0.64]; P < 0.001). Median hypoglycemia area under the curve was reduced by 81%, and hypoglycemia lasting >2 h was reduced by 74%. Overnight sensor glucose was >180 mg/dL during 57% of control nights and 59% of intervention nights (P = 0.17), while morning blood glucose was >180 mg/dL following 21% and 27% of nights, respectively (P < 0.001), and >250 mg/dL following 6% and 6%, respectively. Morning ketosis was present <1% of the time in each arm. Use of a nocturnal low-glucose suspend system can substantially reduce overnight hypoglycemia without an increase in morning ketosis. © 2014 by the American Diabetes Association.

  10. Design and evaluation of a dry coated drug delivery system with floating-pulsatile release.

    PubMed

    Zou, Hao; Jiang, Xuetao; Kong, Lingshan; Gao, Shen

    2008-01-01

    The objective of this work was to develop and evaluate a floating-pulsatile drug delivery system intended for chronopharmacotherapy. Floating-pulsatile concept was applied to increase the gastric residence of the dosage form having lag phase followed by a burst release. To overcome limitations of various approaches for imparting buoyancy, we generated the system which consisted of three different parts, a core tablet, containing the active ingredient, an erodible outer shell and a top cover buoyant layer. The dry coated tablet consists in a drug-containing core, coated by a hydrophilic erodible polymer which is responsible for a lag phase in the onset of pulsatile release. The buoyant layer, prepared with Methocel K4M, Carbopol 934P and sodium bicarbonate, provides buoyancy to increase the retention of the oral dosage form in the stomach. The effect of the hydrophilic erodible polymer characteristics on the lag time and drug release was investigated. Developed formulations were evaluated for their buoyancy, dissolution and pharmacokinetic, as well gamma-scintigraphically. The results showed that a certain lag time before the drug released generally due to the erosion of the dry coated layer. Floating time was controlled by the quantity and composition of the buoyant layer. Both pharmacokinetic and gamma-scintigraphic data point out the capability of the system of prolonged residence of the tablets in the stomach and releasing drugs after a programmed lag time. (c) 2007 Wiley-Liss, Inc.

  11. Oleyl group-functionalized insulating gate transistors for measuring extracellular pH of floating cells

    NASA Astrophysics Data System (ADS)

    Imaizumi, Yuki; Goda, Tatsuro; Toya, Yutaro; Matsumoto, Akira; Miyahara, Yuji

    2016-01-01

    The extracellular ionic microenvironment has a close relationship to biological activities such as by cellular respiration, cancer development, and immune response. A system composed of ion-sensitive field-effect transistors (ISFET), cells, and program-controlled fluidics has enabled the acquisition of real-time information about the integrity of the cell membrane via pH measurement. Here we aimed to extend this system toward floating cells such as T lymphocytes for investigating complement activation and pharmacokinetics through alternations in the plasma membrane integrity. We functionalized the surface of tantalum oxide gate insulator of ISFET with oleyl-tethered phosphonic acid for interacting with the plasma membranes of floating cells without affecting the cell signaling. The surface modification was characterized by X-ray photoelectron spectroscopy and water contact angle measurements. The Nernst response of -37.8 mV/pH was obtained for the surface-modified ISFET at 37 °C. The oleyl group-functionalized gate insulator successfully captured Jurkat T cells in a fluidic condition without acute cytotoxicity. The system was able to record the time course of pH changes at the cells/ISFET interface during the process of instant addition and withdrawal of ammonium chloride. Further, the plasma membrane injury of floating cells after exposure by detergent Triton™ X-100 was successfully determined using the modified ISFET with enhanced sensitivity as compared with conventional hemolysis assays.

  12. Oleyl group-functionalized insulating gate transistors for measuring extracellular pH of floating cells

    PubMed Central

    Imaizumi, Yuki; Goda, Tatsuro; Toya, Yutaro; Matsumoto, Akira; Miyahara, Yuji

    2016-01-01

    Abstract The extracellular ionic microenvironment has a close relationship to biological activities such as by cellular respiration, cancer development, and immune response. A system composed of ion-sensitive field-effect transistors (ISFET), cells, and program-controlled fluidics has enabled the acquisition of real-time information about the integrity of the cell membrane via pH measurement. Here we aimed to extend this system toward floating cells such as T lymphocytes for investigating complement activation and pharmacokinetics through alternations in the plasma membrane integrity. We functionalized the surface of tantalum oxide gate insulator of ISFET with oleyl-tethered phosphonic acid for interacting with the plasma membranes of floating cells without affecting the cell signaling. The surface modification was characterized by X-ray photoelectron spectroscopy and water contact angle measurements. The Nernst response of −37.8 mV/pH was obtained for the surface-modified ISFET at 37 °C. The oleyl group-functionalized gate insulator successfully captured Jurkat T cells in a fluidic condition without acute cytotoxicity. The system was able to record the time course of pH changes at the cells/ISFET interface during the process of instant addition and withdrawal of ammonium chloride. Further, the plasma membrane injury of floating cells after exposure by detergent Triton™ X-100 was successfully determined using the modified ISFET with enhanced sensitivity as compared with conventional hemolysis assays. PMID:27877886

  13. Formulation and evaluation of atenolol floating bioadhesive system using optimized polymer blends

    PubMed Central

    Siddam, Haritha; Kotla, Niranjan G.; Maddiboyina, Balaji; Singh, Sima; Sunnapu, Omprakash; Kumar, Anil; Sharma, Dinesh

    2016-01-01

    Introduction: Oral sustained release gastro retentive dosage forms offer several advantages for drugs having absorption from the upper gastrointestinal tract to improve the bioavailability of medications which have narrow absorption window. The aim of the study was to develop a floating bioadhesive drug delivery system exhibiting a unique combination of floatation and bioadhesion to prolong the residence in the stomach using atenolol as a model drug. Methods: Prior to compression, polymeric blend(s) were evaluated for flow properties. The tablets were prepared by direct compression method using bioadhesive polymer like Carbopol 934P and hydrophilic polymers like HPMC K4M, HPMC K15M, and HPMC K100M. The prepared tablets were evaluated for physical characteristics, bioadhesive strength, buoyancy lag time, swelling index and in vitro drug release studies. Results: The mean bioadhesive strength was found to be in the range of 16.2 to 52.1 gm. The optimized blend (F11) showed 92.3% drug releases after 24 hrs. Whilst, increase in concentration of carbopol 934P, bioadhesive strength and swelling index was increased with slow release. The n values of optimized formulations were found in the range of 0.631-0.719 indicating non-fickian anomalous type transport mechanism. Conclusion: The study aided in developing an ideal once-a-day gastro retentive floating drug delivery system with improved floating, swelling and bioadhesive characteristics with better bioavailability. PMID:27051631

  14. Effects of Second-Order Hydrodynamics on a Semisubmersible Floating Offshore Wind Turbine: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bayati, I.; Jonkman, J.; Robertson, A.

    2014-07-01

    The objective of this paper is to assess the second-order hydrodynamic effects on a semisubmersible floating offshore wind turbine. Second-order hydrodynamics induce loads and motions at the sum- and difference-frequencies of the incident waves. These effects have often been ignored in offshore wind analysis, under the assumption that they are significantly smaller than first-order effects. The sum- and difference-frequency loads can, however, excite eigenfrequencies of the system, leading to large oscillations that strain the mooring system or vibrations that cause fatigue damage to the structure. Observations of supposed second-order responses in wave-tank tests performed by the DeepCwind consortium at themore » MARIN offshore basin suggest that these effects might be more important than originally expected. These observations inspired interest in investigating how second-order excitation affects floating offshore wind turbines and whether second-order hydrodynamics should be included in offshore wind simulation tools like FAST in the future. In this work, the effects of second-order hydrodynamics on a floating semisubmersible offshore wind turbine are investigated. Because FAST is currently unable to account for second-order effects, a method to assess these effects was applied in which linearized properties of the floating wind system derived from FAST (including the 6x6 mass and stiffness matrices) are used by WAMIT to solve the first- and second-order hydrodynamics problems in the frequency domain. The method has been applied to the OC4-DeepCwind semisubmersible platform, supporting the NREL 5-MW baseline wind turbine. The loads and response of the system due to the second-order hydrodynamics are analysed and compared to first-order hydrodynamic loads and induced motions in the frequency domain. Further, the second-order loads and induced response data are compared to the loads and motions induced by aerodynamic loading as solved by FAST.« less

  15. Smart Novel Semi-Active Tuned Mass Damper for Fixed-Bottom and Floating Offshore Wind (Paper)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez Tsouroukdissian, Arturo; Lackner, Mathew; Cross-Whiter, John

    The intention of this paper is to present the results of a novel smart semi-active tuned mass damper (SA-TMD), which mitigates unwanted loads for both fixed-bottom and floating offshore wind systems. The paper will focus on the most challenging water depths for both fixed-bottom and floating systems. A close to 38m Monopile and 55m Tension Leg Platform (TLP) will be considered. A technical development and trade-off analysis will be presented comparing the new system with existing passive non-linear TMD (N-TMD) technology and semi-active. TheSATMD works passively and activates itself with low power source under unwanted dynamic loading in less thanmore » 60msec. It is composed of both variable stiffness and damping elements coupled to a central pendulum mass. The analysis has been done numerically in both FAST(NREL) and Orcaflex (Orcina), and integrated in the Wind Turbine system employing CAD/CAE. The results of this work will pave the way for experimental testing to complete the technology qualification process. The load reductions under extreme and fatigue cases reach up significant levels at tower base, consequently reducing LCOE for fixed-bottom to floating wind solutions. The nacelle acceleration is reduced substantially under severe random wind and sea states, reducing the risks of failure of electromechanical components and blades at the rotor nacelle assembly. The SA-TMD system isa new technology that has not been applied previously in wind solutions. Structural damping devices aim to increase offshore wind turbine system robustness and reliability, which eases multiple substructures installations and global stability.« less

  16. Bioavailability enhancement of baclofen by gastroretentive floating formulation: statistical optimization, in vitro and in vivo pharmacokinetic studies.

    PubMed

    Thakar, Krishna; Joshi, Garima; Sawant, Krutika K

    2013-06-01

    The study was aimed to improve bioavailability of baclofen by developing gastroretentive floating drug delivery system (GFDDS). Preliminary optimization was done to select various release retardants to obtain minimum floating lag time, maximum floating duration and sustained release. Optimization by 3(2) factorial design was done using Polyox WSR 303 (X1) and HPMC K4M (X2) as independent variables and cumulative percentage drug released at 6 h (Q6h) as dependent variable. Optimized formulation showed floating lag time of 4-5 s, floated for more than 12 h and released the drug in sustained manner. In vitro release followed zero ordered kinetics and when fitted to Korsemeyer Peppas model, indicated drug release by combination of diffusion as well as chain relaxation. In vivo floatability study confirmed floatation for more than 6 h. In vivo pharmacokinetic studies in rabbits showed Cmax of 189.96 ± 13.04 ng/mL and Tmax of 4 ± 0.35 h for GFDDS. The difference for AUC(0-T) and AUC(0-∞) between the test and reference formulation was statistically significant (p > 0.05). AUC(0-T) and AUC(0-∞) for GFDDS was 2.34 and 2.43 times greater than the marketed formulation respectively. GFDDS provided prolonged gastric residence and showed significant increase in bioavailability of baclofen.

  17. Toward Future Photovoltaic-Based Agriculture in Sea.

    PubMed

    Moustafa, Khaled

    2016-04-01

    To meet the challenges of climate change and water shortages, combining solar energy-based seawater desalination technologies with floating agriculture stations in one innovative hybrid system would be worthy of investigation for dry and sunny regions for seawater desalination and crop production within the same platform. Here, I discuss the feasibility of such a 'floating farm' or 'bluehouse' in the sea, by comparing it with the use of terrestrial greenhouses. I also debate the potential advantages and shortcomings of such a system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Y-MP floating point and Cholesky factorization

    NASA Technical Reports Server (NTRS)

    Carter, Russell

    1991-01-01

    The floating point arithmetics implemented in the Cray 2 and Cray Y-MP computer systems are nearly identical, but large scale computations performed on the two systems have exhibited significant differences in accuracy. The difference in accuracy is analyzed for Cholesky factorization algorithm, and it is found that the source of the difference is the subtract magnitude operation of the Cray Y-MP. The results from numerical experiments for a range of problem sizes are presented, and an efficient method for improving the accuracy of the factorization obtained on the Y-MP is presented.

  19. STS-26 Pilot Covey floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Pilot Richard O. Covey, wearing newly designed launch and entry suit (LES), floats in single-occupant life raft during simulations in the JSC Weightless Environment Training Facility Bldg 29 pool. During the simulation of escape and rescue operations, the crew escape system (CES) pole mode of egress from the Space Shuttle was utilized.

  20. Development of an Automatic Testing Platform for Aviator's Night Vision Goggle Honeycomb Defect Inspection.

    PubMed

    Jian, Bo-Lin; Peng, Chao-Chung

    2017-06-15

    Due to the direct influence of night vision equipment availability on the safety of night-time aerial reconnaissance, maintenance needs to be carried out regularly. Unfortunately, some defects are not easy to observe or are not even detectable by human eyes. As a consequence, this study proposed a novel automatic defect detection system for aviator's night vision imaging systems AN/AVS-6(V)1 and AN/AVS-6(V)2. An auto-focusing process consisting of a sharpness calculation and a gradient-based variable step search method is applied to achieve an automatic detection system for honeycomb defects. This work also developed a test platform for sharpness measurement. It demonstrates that the honeycomb defects can be precisely recognized and the number of the defects can also be determined automatically during the inspection. Most importantly, the proposed approach significantly reduces the time consumption, as well as human assessment error during the night vision goggle inspection procedures.

  1. Feasibility of Floating Platform Systems for Wind Turbines: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musial, W.; Butterfield, S.; Boone, A.

    This paper provides a general technical description of several types of floating platforms for wind turbines. Platform topologies are classified into multiple- or single-turbine floaters and by mooring method. Platforms using catenary mooring systems are contrasted to vertical mooring systems and the advantages and disadvantages are discussed. Specific anchor types are described in detail. A rough cost comparison is performed for two different platform architectures using a generic 5-MW wind turbine. One platform is a Dutch study of a tri-floater platform using a catenary mooring system, and the other is a mono-column tension-leg platform developed at the National Renewable Energymore » Laboratory. Cost estimates showed that single unit production cost is $7.1 M for the Dutch tri-floater, and $6.5 M for the NREL TLP concept. However, value engineering, multiple unit series production, and platform/turbine system optimization can lower the unit platform costs to $4.26 M and $2.88 M, respectively, with significant potential to reduce cost further with system optimization. These foundation costs are within the range necessary to bring the cost of energy down to the DOE target range of $0.05/kWh for large-scale deployment of offshore floating wind turbines.« less

  2. Assessment of the abnormal growth of floating macrophytes in Winam Gulf (Kenya) by using MODIS imagery time series

    NASA Astrophysics Data System (ADS)

    Fusilli, L.; Collins, M. O.; Laneve, G.; Palombo, A.; Pignatti, S.; Santini, F.

    2013-02-01

    The objective of this research study is to assess the capability of time-series of MODIS imagery to provide information suitable for enhancing the understanding of the temporal cycles shown by the abnormal growth of the floating macrophytes in order to support monitoring and management action of Lake Victoria water resources. The proliferation of invasive plants and aquatic weeds is of growing concern. Starting from 1989, Lake Victoria has been interested by the high infestation of water hyacinth with significant socio-economic impact on riparian populations. In this paper, we describe an approach based on the time-series of MODIS to derive the temporal behaviour, the abundance and distribution of the floating macrophytes in the Winam Gulf (Kenyan portion of the Lake Victoria) and its possible links to the concentrations of the main water constituencies. To this end, we consider the NDVI values computed from the MODIS imagery time-series from 2000 to 2009 to identify the floating macrophytes cover and an appropriate bio-optical model to retrieve, by means of an inverse procedure, the concentrations of chlorophyll a, coloured dissolved organic matter and total suspended solid. The maps of the floating vegetation based on the NDVI values allow us to assess the spatial and temporal dynamics of the weeds with high time resolution. A floating vegetation index (FVI) has been introduced for describing the weeds pollution level. The results of the analysis show a consistent temporal relation between the water constituent concentrations within the Winam Gulf and the FVI, especially in the proximity of the greatest proliferation of floating vegetation in the last 10 years that occurred between the second half of 2006 and the first half of 2007.The adopted approach will be useful to implement an automatic system for monitoring and predicting the floating macrophytes proliferation in Lake Victoria.

  3. Formulation and evaluation of floating matrix tablet of stavudine

    PubMed Central

    Prajapati, Pankaj H; Nakum, Vijay V; Patel, Chhagan N

    2012-01-01

    Background/Aim: The purpose of the study was to prolong the gastric residence time of stavudine by designing its floating tablets and to study the influence of different polymers on its release rate. Materials and Methods: The floating mix matrix tablets of stavudine were prepared by melt granulation method. Beeswax was used as hydrophobic meltable material. Hydroxypropyl methylcellulose (HPMC), sodium bicarbonate, and ethyl cellulose were used as matrixing agent, gas generating agent, and floating enhancer, respectively. The prepared tablets were evaluated for physicochemical parameters such as hardness, weight variation, friability, floating properties (floating lag time, total floating time), drug content, stability study, and in vitro drug release. The drug- polymer interaction was studied by Differential Scanning Calorimetry (DSC) thermal analysis and Fourier transform infared (FT-IR). Results: The floating lag time of all the formulations was within the prescribed limit (<3 min). All the formulations showed good matrix integrity and retarded the release of drug for 12 h except the formulation F5.The concentration of beeswax (X1), HPMC K4M (X2), and ethyl cellulose (X3) were selected as independent variables and drug release values at 1 (Q1), at 6 (Q6) and at 12 h (Q12) as dependent variables. Formulation F7 was selected as an optimum formulation as it showed more similarity in dissolution profile with theoretical profile (similarity factor, f2 = 70.91). The dissolution of batch F7 can be described by zero-order kinetics (R2 =0.9936) with anomalous (non-Fickian) diffusion as the release mechanism (n=0.545). There was no difference observed in release profile after temperature sensitivity study at 40°C/75% relative humidity (RH) for 1 month. Conclusion: It can be concluded from this study that the combined mix matrix system containing hydrophobic and hydrophilic polymer minimized the burst release of drug from the tablet and achieved a drug release by zero-order kinetics, which is practically difficult with only hydrophilic matrix. PMID:23119237

  4. Benchmark calculations of excess electrons in water cluster cavities: balancing the addition of atom-centered diffuse functions versus floating diffuse functions.

    PubMed

    Zhang, Changzhe; Bu, Yuxiang

    2016-09-14

    Diffuse functions have been proved to be especially crucial for the accurate characterization of excess electrons which are usually bound weakly in intermolecular zones far away from the nuclei. To examine the effects of diffuse functions on the nature of the cavity-shaped excess electrons in water cluster surroundings, both the HOMO and LUMO distributions, vertical detachment energies (VDEs) and visible absorption spectra of two selected (H2O)24(-) isomers are investigated in the present work. Two main types of diffuse functions are considered in calculations including the Pople-style atom-centered diffuse functions and the ghost-atom-based floating diffuse functions. It is found that augmentation of atom-centered diffuse functions contributes to a better description of the HOMO (corresponding to the VDE convergence), in agreement with previous studies, but also leads to unreasonable diffuse characters of the LUMO with significant red-shifts in the visible spectra, which is against the conventional point of view that the more the diffuse functions, the better the results. The issue of designing extra floating functions for excess electrons has also been systematically discussed, which indicates that the floating diffuse functions are necessary not only for reducing the computational cost but also for improving both the HOMO and LUMO accuracy. Thus, the basis sets with a combination of partial atom-centered diffuse functions and floating diffuse functions are recommended for a reliable description of the weakly bound electrons. This work presents an efficient way for characterizing the electronic properties of weakly bound electrons accurately by balancing the addition of atom-centered diffuse functions and floating diffuse functions and also by balancing the computational cost and accuracy of the calculated results, and thus is very useful in the relevant calculations of various solvated electron systems and weakly bound anionic systems.

  5. Swelling/Floating Capability and Drug Release Characterizations of Gastroretentive Drug Delivery System Based on a Combination of Hydroxyethyl Cellulose and Sodium Carboxymethyl Cellulose

    PubMed Central

    Chen, Ying-Chen; Ho, Hsiu-O; Liu, Der-Zen; Siow, Wen-Shian; Sheu, Ming-Thau

    2015-01-01

    The aim of this study was to characterize the swelling and floating behaviors of gastroretentive drug delivery system (GRDDS) composed of hydroxyethyl cellulose (HEC) and sodium carboxymethyl cellulose (NaCMC) and to optimize HEC/NaCMC GRDDS to incorporate three model drugs with different solubilities (metformin, ciprofloxacin, and esomeprazole). Various ratios of NaCMC to HEC were formulated, and their swelling and floating behaviors were characterized. Influences of media containing various NaCl concentrations on the swelling and floating behaviors and drug solubility were also characterized. Finally, release profiles of the three model drugs from GRDDS formulation (F1-4) and formulation (F1-1) were examined. Results demonstrated when the GRDDS tablets were tested in simulated gastric solution, the degree of swelling at 6 h was decreased for each formulation that contained NaCMC in comparison to those in de-ionized water (DIW). Of note, floating duration was enhanced when in simulated gastric solution compared to DIW. Further, the hydration of tablets was found to be retarded as the NaCl concentration in the medium increased resulting in smaller gel layers and swelling sizes. Dissolution profiles of the three model drugs in media containing various concentrations of NaCl showed that the addition of NaCl to the media affected the solubility of the drugs, and also their gelling behaviors, resulting in different mechanisms for controlling a drug’s release. The release mechanism of the freely water-soluble drug, metformin, was mainly diffusion-controlled, while those of the water-soluble drug, ciprofloxacin, and the slightly water-soluble drug, esomeprazole, were mainly anomalous diffusion. Overall results showed that the developed GRDDS composed of HEC 250HHX and NaCMC of 450 cps possessed proper swelling extents and desired floating periods with sustained-release characteristics. PMID:25617891

  6. STS-26 Pilot Covey floats in life raft during JSC WETF exercises

    NASA Image and Video Library

    1988-07-08

    S88-42425 (20 July 1988) --- STS-26 Discovery, Orbiter Vehicle (OV) 103, Pilot Richard O. Covey, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle.

  7. STS-26 Pilot Covey floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Pilot Richard O. Covey, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. Covey has paddle-like gloves on his hands. The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle.

  8. Optimization studies on compression coated floating-pulsatile drug delivery of bisoprolol.

    PubMed

    Jagdale, Swati C; Bari, Nilesh A; Kuchekar, Bhanudas S; Chabukswar, Aniruddha R

    2013-01-01

    The purpose of the present work was to design and optimize compression coated floating pulsatile drug delivery systems of bisoprolol. Floating pulsatile concept was applied to increase the gastric residence of the dosage form having lag phase followed by a burst release. The prepared system consisted of two parts: a core tablet containing the active ingredient and an erodible outer shell with gas generating agent. The rapid release core tablet (RRCT) was prepared by using superdisintegrants with active ingredient. Press coating of optimized RRCT was done by polymer. A 3² full factorial design was used for optimization. The amount of Polyox WSR205 and Polyox WSR N12K was selected as independent variables. Lag period, drug release, and swelling index were selected as dependent variables. Floating pulsatile release formulation (FPRT) F13 at level 0 (55 mg) for Polyox WSR205 and level +1 (65 mg) for Polyox WSR N12K showed lag time of 4 h with >90% drug release. The data were statistically analyzed using ANOVA, and P < 0.05 was statistically significant. Release kinetics of the optimized formulation best fitted the zero order model. In vivo study confirms burst effect at 4 h in indicating the optimization of the dosage form.

  9. Buoyancy-generating agents for stomach-specific drug delivery: an overview with special emphasis on floating behavior.

    PubMed

    Ishak, Rania A H

    2015-01-01

    Gastric retentive drug delivery provides a promising technology exhibiting an extended gastric residence and a drug release independent of patient related variables. It is usually useful in improving local gastric treatment as well as overcoming drug-related problems .i.e. drugs having narrow absorption window, short half-life or low intestinal solubility. Buoyancy is considered one of the most promising approaches for gastro-retention of dosage forms. Floating drug delivery systems have a bulk density lower than gastric fluids and thus remain buoyant in the stomach causing an increase in gastric residence time. The buoyancy of these systems is attained by the aid of substances responsible to generate the low density. Various agents with different mechanisms were adopted either gas-generating agents, air entrapping swellable polymers, inherent low density substances, porous excipients, hollow/porous particles inducing preparation techniques or sublimating agents. Therefore, this review gives an exclusive descriptive classification of the different categories of these buoyancy-generating agents while representing the related research works. An overview is also conducted to describe relevant techniques assessing the floating behavior of such dosage forms either in vitro or in vivo. Finally, a collection representing FDA-approved floating pharmaceutical products is adopted with emphasis on the buoyancy-generating agent type used in each product.

  10. Aerodynamic and hydrodynamic model tests of the Enserch Garden Banks floating production facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.W.; Bauer, T.C.; Kelly, P.J.

    1995-12-01

    This paper presents the results of aerodynamic and hydrodynamic model tests of the Enserch Garden Banks, a semisubmersible Floating Production Facility (FPF) moored in 2,190-ft waters. During the wind tunnel tests, the steady component of wind and current forces/moments at various skew and heel axes were measured. The results were compared and calibrated against analytical calculations using techniques recommended by ABS and API. During the wave basin recommend test the mooring line tensions and vessel motions including the effects of dynamic wind and current were measured. An analytical calculation of the airgap, vessel motions, and mooring line loads were comparedmore » with wave basin model test results. This paper discusses the test objectives, test setups and agendas for wind and wave basin testing of a deepwater permanently moored floating production system. The experience from these tests and the comparison of measured tests results with analytical calculations will be of value to designers and operators contemplating the use of a semisubmersible based floating production system. The analysis procedures are aimed at estimating (1) vessel motions, (2) airgap, and (3) mooring line tensions with reasonable accuracy. Finally, this paper demonstrates how the model test results were interpolated and adapted in the design loop.« less

  11. Optimization Studies on Compression Coated Floating-Pulsatile Drug Delivery of Bisoprolol

    PubMed Central

    Jagdale, Swati C.; Bari, Nilesh A.; Kuchekar, Bhanudas S.; Chabukswar, Aniruddha R.

    2013-01-01

    The purpose of the present work was to design and optimize compression coated floating pulsatile drug delivery systems of bisoprolol. Floating pulsatile concept was applied to increase the gastric residence of the dosage form having lag phase followed by a burst release. The prepared system consisted of two parts: a core tablet containing the active ingredient and an erodible outer shell with gas generating agent. The rapid release core tablet (RRCT) was prepared by using superdisintegrants with active ingredient. Press coating of optimized RRCT was done by polymer. A 32 full factorial design was used for optimization. The amount of Polyox WSR205 and Polyox WSR N12K was selected as independent variables. Lag period, drug release, and swelling index were selected as dependent variables. Floating pulsatile release formulation (FPRT) F13 at level 0 (55 mg) for Polyox WSR205 and level +1 (65 mg) for Polyox WSR N12K showed lag time of 4 h with >90% drug release. The data were statistically analyzed using ANOVA, and P < 0.05 was statistically significant. Release kinetics of the optimized formulation best fitted the zero order model. In vivo study confirms burst effect at 4 h in indicating the optimization of the dosage form. PMID:24367788

  12. An efficient low frequency horizontal diamagnetic levitation mechanism based vibration energy harvester

    NASA Astrophysics Data System (ADS)

    Palagummi, S.; Yuan, F. G.

    2016-04-01

    This article identifies and studies key parameters that characterize a horizontal diamagnetic levitation (HDL) mechanism based low frequency vibration energy harvester with the aim of enhancing performance metrics such as efficiency and volume figure of merit (FoMv). The HDL mechanism comprises of three permanent magnets and two diamagnetic plates. Two of the magnets, aka lifting magnets, are placed co-axially at a distance such that each attract a centrally located magnet, aka floating magnet, to balance its weight. This floating magnet is flanked closely by two diamagnetic plates which stabilize the levitation in the axial direction. The influence of the geometry of the floating magnet, the lifting magnet and the diamagnetic plate are parametrically studied to quantify their effects on the size, stability of the levitation mechanism and the resonant frequency of the floating magnet. For vibration energy harvesting using the HDL mechanism, a coil geometry and eddy current damping are critically discussed. Based on the analysis, an efficient experimental system is setup which showed a softening frequency response with an average system efficiency of 25.8% and a FoMv of 0.23% when excited at a root mean square acceleration of 0.0546 m/s2 and at frequency of 1.9 Hz.

  13. Active structural control of a floating wind turbine with a stroke-limited hybrid mass damper

    NASA Astrophysics Data System (ADS)

    Hu, Yaqi; He, Erming

    2017-12-01

    Floating wind turbines are subjected to more severe structural loads than fixed-bottom wind turbines due to additional degrees of freedom (DOFs) of their floating foundations. It's a promising way of using active structural control method to improve the structural responses of floating wind turbines. This paper investigates an active vibration control strategy for a barge-type floating wind turbine by setting a stroke-limited hybrid mass damper (HMD) in the turbine's nacelle. Firstly, a contact nonlinear modeling method for the floating wind turbine with clearance between the HMD and the stroke limiters is presented based on Euler-Lagrange's equations and an active control model of the whole system is established. The structural parameters are validated for the active control model and an equivalent load coefficient method is presented for identifying the wind and wave disturbances. Then, a state-feedback linear quadratic regulator (LQR) controller is designed to reduce vibration and loads of the wind turbine, and two optimization methods are combined to optimize the weighting coefficients when considering the stroke of the HMD and the active control power consumption as constraints. Finally, the designed controllers are implemented in high fidelity simulations under five typical wind and wave conditions. The results show that active HMD control strategy is shown to be achievable and the designed controllers could further reduce more vibration and loads of the wind turbine under the constraints of stroke limitation and power consumption. "V"-shaped distribution of the TMD suppression effect is inconsistent with the Weibull distribution in practical offshore floating wind farms, and the active HMD control could overcome this shortcoming of the passive TMD.

  14. Design, development and evaluation of clopidogrel bisulfate floating tablets.

    PubMed

    Rao, K Rama Koteswara; Lakshmi, K Rajya

    2014-01-01

    The objective of the present work was to formulate and to characterize a floating drug delivery system for clopidogrel bisulphate to improve bioavailability and to minimize the side effects of the drug such as gastric bleeding and drug resistance development. Clopidogrel floating tablets were prepared by direct compression technique by the use of three polymers xanthan gum, hydroxypropyl methylcellulose (HPMC) K15M and HPMC K4M in different concentrations (20%, 25% and 30% w/w). Sodium bicarbonate (15% w/w) and microcrystalline cellulose (30% w/w) were used as gas generating agent and diluent respectively. Studies were carried out on floating behavior and influence of type of polymer on drug release rate. All the formulations were subjected to various quality control and in-vitro dissolution studies in 0.1 N hydrochloric acid (1.2 pH) and corresponding dissolution data were fitted to popular release kinetic equations in order to evaluate release mechanisms and kinetics. All the clopidogrel floating formulations followed first order kinetics, Higuchi drug release kinetics with diffusion as the dominant mechanism of drug release. As per Korsmeyer-Peppas equation, the release exponent "n" ranged 0.452-0.654 indicating that drug release from all the formulations was by non-Fickian diffusion mechanism. The drug release rate of clopidogrel was found to be affected by the type and concentration of the polymer used in the formulation (P < 0.05). As the concentration of the polymer was increased, the drug release was found to be retarded. Based on the results, clopidogrel floating tablets prepared by employing xanthan gum at concentration 25% w/w (formulation F2) was the best formulation with desired in-vitro floating time and drug dissolution.

  15. Development of Multiple-Unit Floating Drug Delivery System of Clarithromycin: Formulation, in vitro Dissolution by Modified Dissolution Apparatus, in vivo Radiographic Studies in Human Volunteers.

    PubMed

    Reddy, Arun B; Reddy, Narendar D

    2017-07-01

    Clarithromycin (CM), a broad spectrum macrolide antibiotic used to eradicate H. pylori in peptic ulcer. Clarithromycin (CM) is well absorbed from the gastrointestinal tract, but has a bioavailability of 50% due to rapid biodegradation. The aim of this investigation was to increase the gastric residence time, and to control the drug release of clarithromycin by formulating into multiple unit floating mini-tablets. Floating tablets were prepared by using direct compression method with HPMC K 4 M and Polyox WSR 1105 as release retarded polymers and sodium bicarbonate as gas generating agent. The prepared mini-tablets were evaluated for thickness, weight variation, friability, hardness, drug content, in vitro buoyancy, swelling studies, in vitro dissolution studies by using modified Rossett-Rice test and in vivo radiographic studies in healthy human volunteers in fasting conditions. DSC analysis revealed that no interaction between drug and excipients. All the physical parameters of the tablets were within the acceptable limits. The optimized formulation (F6) had showed controlled drug release of 99.16±3.22% in 12 h, by zero-order release kinetics, along with floating lag time of 9.5±1.28 s and total floating time of 12±0.14 h. X-ray imaging studies revealed that in vivo gastric residence time of clarithromycin floating mini-tablet in the stomach was about 3.5 h. The results demonstrated that the developed floating mini-tablets of clarithromycin caused significant enhancement in gastric retention time along with sustained effect and increased oral bioavailability. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Atmospheric exchange of carbon dioxide and methane of a small water body and a floating mat in the Luther Marsh peatland, Ontario, Canada

    NASA Astrophysics Data System (ADS)

    Burger, Magdalena; Berger, Sina; Blodau, Christian

    2015-04-01

    Recent investigations have suggested that small water bodies cover larger areas in northern peatlands than previously assumed. Their role in the carbon cycle and gas exchange rates are poorly constrained so far. To address this issue we measured CO2 and CH4 fluxes on a small water body (ca. 700 m2) and the surrounding floating mat in the Luther Marsh peatland in Ontario, Canada from July to September 2014. To this end we used closed chambers combined with a portable Los Gatos high-resolution trace gas analyzer at different water depths and distances from the shore on the pond and with different dominating plant types on the floating mat surrounding the pond. In addition, CO2 concentrations were recorded in high temporal resolution using an infrared sensor system during selected periods. Air and water temperature, humidity and temperature of the floating mat, wind speed and direction, photosynthetically active radiation, air pressure and relative humidity were also recorded as auxiliary data at the study site. The results show that pond and floating mat were sources of methane throughout the whole measuring period. Methane emissions via the ebullition pathway occurred predominantly near the shore and on the floating mat. During the daytime measurements the floating mat acted as a net sink and the pond as a net source of CO2. The dynamics of CO2 exchange was also strongly time dependent, as CO2 emissions from the pond strongly increased after mid-August. This suggests that photosynthesis was more affected by seasonal decline than respiration process in the pond and that the allochthonous component of the CO2 flux increased in relative importance towards fall.

  17. Airborne electromagnetic bathymetry investigations in Port Lincoln, South Australia - comparison with an equivalent floating transient electromagnetic system

    NASA Astrophysics Data System (ADS)

    Vrbancich, Julian

    2011-09-01

    Helicopter time-domain airborne electromagnetic (AEM) methodology is being investigated as a reconnaissance technique for bathymetric mapping in shallow coastal waters, especially in areas affected by water turbidity where light detection and ranging (LIDAR) and hyperspectral techniques may be limited. Previous studies in Port Lincoln, South Australia, used a floating AEM time-domain system to provide an upper limit to the expected bathymetric accuracy based on current technology for AEM systems. The survey lines traced by the towed floating system were also flown with an airborne system using the same transmitter and receiver electronic instrumentation, on two separate occasions. On the second occasion, significant improvements had been made to the instrumentation to reduce the system self-response at early times. A comparison of the interpreted water depths obtained from the airborne and floating systems is presented, showing the degradation in bathymetric accuracy obtained from the airborne data. An empirical data correction method based on modelled and observed EM responses over deep seawater (i.e. a quasi half-space response) at varying survey altitudes, combined with known seawater conductivity measured during the survey, can lead to significant improvements in interpreted water depths and serves as a useful method for checking system calibration. Another empirical data correction method based on observed and modelled EM responses in shallow water was shown to lead to similar improvements in interpreted water depths; however, this procedure is notably inferior to the quasi half-space response because more parameters need to be assumed in order to compute the modelled EM response. A comparison between the results of the two airborne surveys in Port Lincoln shows that uncorrected data obtained from the second airborne survey gives good agreement with known water depths without the need to apply any empirical corrections to the data. This result significantly decreases the data-processing time thereby enabling the AEM method to serve as a rapid reconnaissance technique for bathymetric mapping.

  18. Campaign for Levitation in LDX

    NASA Astrophysics Data System (ADS)

    Garnier, D. T.; Hansen, A. K.; Mauel, M. E.; Ortiz, E. E.; Boxer, A. C.; Ellsworth, J. L.; Karim, I.; Kesner, J.; Michael, P. C.; Zhukovsky, A.

    2006-10-01

    In the past year, preparations have been made for the first flight of the Levitated Dipole Experiment (LDX). LDX, which consists of a 560 kg superconducting coil floating within a 5 m diameter vacuum chamber, is designed to study fusion relevant plasmas confined in a dipole magnetic field. During the spring, a high temperature superconducting levitation coil was integrated into the LDX facility. Testing was undertaken to verify the thermal performance of the coil under expected levitation conditions. In addition, a real-time operating system digital control system was developed that will be used for the levitation control. In July, plasma experiments were conducted with all superconducting magnets in operation. While still supported, roughly 75% of the weight of the floating coil was magnetically lifted by the levitation coil above. A series of plasma experiments were conducted with the same magnetic geometry as will be the case during levitation. During August, the second generation launcher system will be installed. The launcher, which retracts beyond the plasma's last closed field lines during operation, is designed to safely catch the floating coil following an unexpected loss of control. After this installation, levitation experiments will commence.

  19. Damage identification of a TLP floating wind turbine by meta-heuristic algorithms

    NASA Astrophysics Data System (ADS)

    Ettefagh, M. M.

    2015-12-01

    Damage identification of the offshore floating wind turbine by vibration/dynamic signals is one of the important and new research fields in the Structural Health Monitoring (SHM). In this paper a new damage identification method is proposed based on meta-heuristic algorithms using the dynamic response of the TLP (Tension-Leg Platform) floating wind turbine structure. The Genetic Algorithms (GA), Artificial Immune System (AIS), Particle Swarm Optimization (PSO), and Artificial Bee Colony (ABC) are chosen for minimizing the object function, defined properly for damage identification purpose. In addition to studying the capability of mentioned algorithms in correctly identifying the damage, the effect of the response type on the results of identification is studied. Also, the results of proposed damage identification are investigated with considering possible uncertainties of the structure. Finally, for evaluating the proposed method in real condition, a 1/100 scaled experimental setup of TLP Floating Wind Turbine (TLPFWT) is provided in a laboratory scale and the proposed damage identification method is applied to the scaled turbine.

  20. Development of a new instrument for direct skin friction measurements

    NASA Technical Reports Server (NTRS)

    Vakili, A. D.; Wu, J. M.

    1986-01-01

    A device developed for the direct measurement of wall shear stress generated by flows is described. Simple and symmetric in design with optional small moving mass and no internal friction, the features employed in the design eliminate most of the difficulties associated with the traditional floating element balances. The device is basically small and can be made in various sizes. Vibration problems associated with the floating element skin friction balances were found to be minimized due to the design symmetry and optional damping provided. The design eliminates or reduces the errors associated with conventional floating element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer, and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Dynamic measurements could be made in a limited range and measurements in liquids could be performed readily. Measurement made in the three different tunnels show excellent agreement with data obtained by the floating element devices and other techniques.

  1. Global Night-Time Lights for Observing Human Activity

    NASA Technical Reports Server (NTRS)

    Hipskind, Stephen R.; Elvidge, Chris; Gurney, K.; Imhoff, Mark; Bounoua, Lahouari; Sheffner, Edwin; Nemani, Ramakrishna R.; Pettit, Donald R.; Fischer, Marc

    2011-01-01

    We present a concept for a small satellite mission to make systematic, global observations of night-time lights with spatial resolution suitable for discerning the extent, type and density of human settlements. The observations will also allow better understanding of fine scale fossil fuel CO2 emission distribution. The NASA Earth Science Decadal Survey recommends more focus on direct observations of human influence on the Earth system. The most dramatic and compelling observations of human presence on the Earth are the night light observations taken by the Defence Meteorological System Program (DMSP) Operational Linescan System (OLS). Beyond delineating the footprint of human presence, night light data, when assembled and evaluated with complementary data sets, can determine the fine scale spatial distribution of global fossil fuel CO2 emissions. Understanding fossil fuel carbon emissions is critical to understanding the entire carbon cycle, and especially the carbon exchange between terrestrial and oceanic systems.

  2. All-around viewing display system for group activity on life review therapy

    NASA Astrophysics Data System (ADS)

    Sakamoto, Kunio; Okumura, Mitsuru

    2009-10-01

    This paper describes 360 degree viewing display system that can be viewed from any direction. A conventional monitor display is viewed from one direction, i.e., the display has narrow viewing angle and observers cannot view the screen from the opposite side. To solve this problem, we developed the 360 degree viewing display for collaborative tasks on the round table. This developed 360 degree viewing system has a liquid crystal display screen and a 360 degree rotating table by motor. The principle is very simple. The screen of a monitor only rotates at a uniform speed, but the optical techniques are also utilized. Moreover, we have developed a floating 360 degree viewing display that can be viewed from any direction. This new viewing system has a display screen, a rotating table and dual parabolic mirrors. In order to float the only image screen above the table, the rotating mechanism works in the parabolic mirrors. Because the dual parabolic mirrors generate a "mirage" image over the upper mirror, observers can view a floating 2D image on the virtual screen in front of them. Then the observer can view a monitor screen at any position surrounding the round table.

  3. Assembled modules technology for site-specific prolonged delivery of norfloxacin.

    PubMed

    Oliveira, Paulo Renato; Bernardi, Larissa Sakis; Strusi, Orazio Luca; Mercuri, Salvatore; Segatto Silva, Marcos A; Colombo, Paolo; Sonvico, Fabio

    2011-02-28

    The aim of this research was to design and study norfloxacin (NFX) release in floating conditions from compressed hydrophilic matrices of hydroxypropylmethylcellulose (HPMC) or poly(ethylene oxide) (PEO). Module assembling technology for drug delivery system manufacturing was used. Two differently cylindrical base curved matrix/modules, identified as female and male, were assembled in void configuration by friction interlocking their concave bases obtaining a floating release system. Drug release and floatation behavior of this assembly was investigated. Due to the higher surface area exposed to the release medium, faster release was observed for individual modules compared to their assembled configuration, independently on the polymer used and concentration. The release curves analyzed using the Korsmeyer exponential equation and Peppas & Sahlin binomial equation showed that the drug release was controlled both by drug diffusion and polymer relaxation or erosion mechanisms. However, convective transport was predominant with PEO and at low content of polymers. NFX release from PEO polymeric matrix was more erosion dependent than HPMC. The assembled systems were able to float in vitro for up to 240min, indicating that this drug delivery system of norfloxacin could provide gastro-retentive site-specific release for increasing norfloxacin bioavailability. Copyright © 2010. Published by Elsevier B.V.

  4. 14 CFR 27.753 - Main float design.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Main float design. 27.753 Section 27.753... STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Floats and Hulls § 27.753 Main float design. (a) Bag floats. Each bag float must be designed to withstand— (1) The maximum pressure differential...

  5. 14 CFR 29.753 - Main float design.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Main float design. 29.753 Section 29.753... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Floats and Hulls § 29.753 Main float design. (a) Bag floats. Each bag float must be designed to withstand— (1) The maximum pressure differential...

  6. The Unified Floating Point Vector Coprocessor for Reconfigurable Hardware

    NASA Astrophysics Data System (ADS)

    Kathiara, Jainik

    There has been an increased interest recently in using embedded cores on FPGAs. Many of the applications that make use of these cores have floating point operations. Due to the complexity and expense of floating point hardware, these algorithms are usually converted to fixed point operations or implemented using floating-point emulation in software. As the technology advances, more and more homogeneous computational resources and fixed function embedded blocks are added to FPGAs and hence implementation of floating point hardware becomes a feasible option. In this research we have implemented a high performance, autonomous floating point vector Coprocessor (FPVC) that works independently within an embedded processor system. We have presented a unified approach to vector and scalar computation, using a single register file for both scalar operands and vector elements. The Hybrid vector/SIMD computational model of FPVC results in greater overall performance for most applications along with improved peak performance compared to other approaches. By parameterizing vector length and the number of vector lanes, we can design an application specific FPVC and take optimal advantage of the FPGA fabric. For this research we have also initiated designing a software library for various computational kernels, each of which adapts FPVC's configuration and provide maximal performance. The kernels implemented are from the area of linear algebra and include matrix multiplication and QR and Cholesky decomposition. We have demonstrated the operation of FPVC on a Xilinx Virtex 5 using the embedded PowerPC.

  7. Evolution of the ATLAS Nightly Build System

    NASA Astrophysics Data System (ADS)

    Undrus, A.

    2012-12-01

    The ATLAS Nightly Build System is a major component in the ATLAS collaborative software organization, validation, and code approval scheme. For over 10 years of development it has evolved into a factory for automatic release production and grid distribution. The 50 multi-platform branches of ATLAS releases provide vast opportunities for testing new packages, verification of patches to existing software, and migration to new platforms and compilers for ATLAS code that currently contains 2200 packages with 4 million C++ and 1.4 million python scripting lines written by about 1000 developers. Recent development was focused on the integration of ATLAS Nightly Build and Installation systems. The nightly releases are distributed and validated and some are transformed into stable releases used for data processing worldwide. The ATLAS Nightly System is managed by the NICOS control tool on a computing farm with 50 powerful multiprocessor nodes. NICOS provides the fully automated framework for the release builds, testing, and creation of distribution kits. The ATN testing framework of the Nightly System runs unit and integration tests in parallel suites, fully utilizing the resources of multi-core machines, and provides the first results even before compilations complete. The NICOS error detection system is based on several techniques and classifies the compilation and test errors according to their severity. It is periodically tuned to place greater emphasis on certain software defects by highlighting the problems on NICOS web pages and sending automatic e-mail notifications to responsible developers. These and other recent developments will be presented and future plans will be described.

  8. Time-dependent effects of dim light at night on re-entrainment and masking of hamster activity rhythms.

    PubMed

    Frank, David W; Evans, Jennifer A; Gorman, Michael R

    2010-04-01

    Bright light has been established as the most ubiquitous environmental cue that entrains circadian timing systems under natural conditions. Light equivalent in intensity to moonlight (<1 lux), however, also strongly modulates circadian function in a number of entrainment paradigms. For example, compared to completely dark nights, dim nighttime illumination accelerated re-entrainment of hamster activity rhythms to 4-hour phase advances and delays of an otherwise standard laboratory photocycle. The purpose of this study was to determine if a sensitive period existed in the night during which dim illumination had a robust influence on speed of re-entrainment. Male Siberian hamsters were either exposed to dim light throughout the night, for half of the night, or not at all. Compared to dark nights, dim illumination throughout the entire night decreased by 29% the time for the midpoint of the active phase to re-entrain to a 4-hour phase advance and by 26% for a 4-hour delay. Acceleration of advances and delays were also achieved with 5 hours of dim light per night, but effects depended on whether dim light was present in the first half, second half, or first and last quarters of the night. Both during phase shifting and steady-state entrainment, partially lit nights also produced strong positive and negative masking effects, as well as entrainment aftereffects in constant darkness. Thus, even in the presence of a strong zeitgeber, light that might be encountered under a natural nighttime sky potently modulates the circadian timing system of hamsters.

  9. STS-26 MS Nelson during Crew escape system (CES) testing in JSC WETF Bldg 29

    NASA Image and Video Library

    1988-07-08

    S88-42409 (20 July 1988) --- STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) George D. Nelson participates in crew escape system (CES) testing in JSC Weightless Environment Training Facility (WETF) Bldg 29. Nelson, wearing the newly designed (navy blue) launch and entry suit (LES), floats in WETF pool with the aid of an underarm flotation device (modern version of Mas West floats). He awaits the assistance of SCUBA-equipped divers during a simulation of escape and rescue operations utilizing a new CES pole for emergency exit from the Space Shuttle.

  10. 40 CFR 65.45 - External floating roof converted into an internal floating roof.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... External floating roof converted into an internal floating roof. The owner or operator who elects to... 40 Protection of Environment 15 2010-07-01 2010-07-01 false External floating roof converted into an internal floating roof. 65.45 Section 65.45 Protection of Environment ENVIRONMENTAL PROTECTION...

  11. Lessons from pediatrics residency program directors' experiences with work hour limitations in New York State.

    PubMed

    Samuels, Ronald C; Chi, Grace W; Rauch, Daniel A; Palfrey, Judith S; Shelov, Steven P

    2005-05-01

    To evaluate the impact of residency work hour limitations on pediatrics residency programs in New York State, and to learn lessons that can be used nationally with the implementation of the Accreditation Council of Graduate Medical Education's similar rules. A three-page questionnaire was mailed to all pediatrics residency program directors in New York. The questionnaire assessed methods used to accommodate the work hour limitations and perceptions of the limitations' effects. Twenty-one program directors responded (68%). Only large programs used night floats and night teams to meet work hour requirements. Programs of all sizes and in all settings used cross coverage and sent residents home immediately post call. About half of the programs hired additional nonresident staff, usually nurse practitioners, physician assistants, and/or attendings. The most frequently reported effects were decreases in the amount of time residents spent in inpatient settings, patient continuity in inpatient settings, flexibility of residents' scheduling, and increased logistical work needed to maintain continuity clinic. A summary of advice to other program directors was "be creative" and "be flexible." New York's pediatrics residency programs used a variety of mechanisms to meet work hour restrictions. Smaller programs had fewer methods available to them to meet such restrictions. Although the logistical work needed to maintain continuity clinic increased greatly, continuity and outpatient settings themselves were not greatly affected by work hour limitations. Inpatient settings were more affected and experienced much more in the way of change.

  12. LWIR passive perception system for stealthy unmanned ground vehicle night operations

    NASA Astrophysics Data System (ADS)

    Lee, Daren; Rankin, Arturo; Huertas, Andres; Nash, Jeremy; Ahuja, Gaurav; Matthies, Larry

    2016-05-01

    Resupplying forward-deployed units in rugged terrain in the presence of hostile forces creates a high threat to manned air and ground vehicles. An autonomous unmanned ground vehicle (UGV) capable of navigating stealthily at night in off-road and on-road terrain could significantly increase the safety and success rate of such resupply missions for warfighters. Passive night-time perception of terrain and obstacle features is a vital requirement for such missions. As part of the ONR 30 Autonomy Team, the Jet Propulsion Laboratory developed a passive, low-cost night-time perception system under the ONR Expeditionary Maneuver Warfare and Combating Terrorism Applied Research program. Using a stereo pair of forward looking LWIR uncooled microbolometer cameras, the perception system generates disparity maps using a local window-based stereo correlator to achieve real-time performance while maintaining low power consumption. To overcome the lower signal-to-noise ratio and spatial resolution of LWIR thermal imaging technologies, a series of pre-filters were applied to the input images to increase the image contrast and stereo correlator enhancements were applied to increase the disparity density. To overcome false positives generated by mixed pixels, noisy disparities from repeated textures, and uncertainty in far range measurements, a series of consistency, multi-resolution, and temporal based post-filters were employed to improve the fidelity of the output range measurements. The stereo processing leverages multi-core processors and runs under the Robot Operating System (ROS). The night-time passive perception system was tested and evaluated on fully autonomous testbed ground vehicles at SPAWAR Systems Center Pacific (SSC Pacific) and Marine Corps Base Camp Pendleton, California. This paper describes the challenges, techniques, and experimental results of developing a passive, low-cost perception system for night-time autonomous navigation.

  13. An array processing system for lunar geochemical and geophysical data

    NASA Technical Reports Server (NTRS)

    Eliason, E. M.; Soderblom, L. A.

    1977-01-01

    A computerized array processing system has been developed to reduce, analyze, display, and correlate a large number of orbital and earth-based geochemical, geophysical, and geological measurements of the moon on a global scale. The system supports the activities of a consortium of about 30 lunar scientists involved in data synthesis studies. The system was modeled after standard digital image-processing techniques but differs in that processing is performed with floating point precision rather than integer precision. Because of flexibility in floating-point image processing, a series of techniques that are impossible or cumbersome in conventional integer processing were developed to perform optimum interpolation and smoothing of data. Recently color maps of about 25 lunar geophysical and geochemical variables have been generated.

  14. Summary of 2006 to 2010 FPMU Measurements of International Space Station Frame Potential Variations

    NASA Technical Reports Server (NTRS)

    Minow, Joseph I.; Wright, Kenneth H., Jr.; Chandler, Michael O.; Coffey, Victoria N.; Craven, Paul D.; Schneider, Todd A.; Parker, Linda N.; Ferguson, Dale C.; Koontz, Steve L.; Alred, John W.

    2010-01-01

    Electric potential variations on the International Space Station (ISS) structure in low Earth orbit are dominated by contributions from interactions of the United States (US) 160 volt solar arrays with the relatively high density, low temperature plasma environment and inductive potentials generated by motion of the large vehicle across the Earth?s magnetic field. The Floating Potential Measurement Unit (FPMU) instrument suite comprising two Langmuir probes, a plasma impedance probe, and a floating potential probe was deployed in August 2006 for use in characterizing variations in ISS potential, the state of the ionosphere along the ISS orbit and its effect on ISS charging, evaluating effects of payloads and visiting vehicles, and for supporting ISS plasma hazard assessments. This presentation summarizes observations of ISS frame potential variations obtained from the FPMU from deployment in 2006 through the current time. We first describe ISS potential variations due to current collection by solar arrays in the day time sector of the orbit including eclipse exit and entry charging events, potential variations due to plasma environment variations in the equatorial anomaly, and visiting vehicles docked to the ISS structure. Next, we discuss potential variations due to inductive electric fields generated by motion of the vehicle across the geomagnetic field and the effects of external electric fields in the ionosphere. Examples of night time potential variations at high latitudes and their possible relationship to auroral charging are described and, finally, we demonstrate effects on the ISS potential due to European Space Agency and US plasma contactor devices.

  15. Investigation of Icing Characteristics of Typical Light Airplane Engine Induction Systems

    NASA Technical Reports Server (NTRS)

    Coles, W. D.

    1949-01-01

    The icing characteristics of two typical light-airplane engine induction systems were investigated using the carburetors and manifolds of engines in the horsepower ranges from 65 to 85 and 165 to 185. The smaller system consisted of a float-type carburetor with an unheated manifold and the larger system consisted of a single-barrel pressure-type carburetor with an oil-jacketed manifold. Carburetor-air temperature and humidity limits of visible and serious Icing were determined for various engine power conditions. Several.methods of achieving ice-free induction systems are discussed along with estimates of surface heating requirements of the various induct ion-system components. A study was also made of the icing characteristics of a typical light-airplane air scoop with an exposed filter and a modified system that provided a normal ram inlet with the filter located in a position to Induce inertia separation of the free water from the charge air. The principle of operation of float-type carburetors is proved to make them inherently more susceptible to icing at the throttle plate than pressure-type carburetors.. The results indicated that proper jacketing and heating of all parts exposed to the fuel spray can satisfactorily reduce or eliminate icing in the float-type carburetor and the manifold. Pressure-type carburetors can be protected from serious Icing by proper location of the fuel-discharge nozzle combined with suitable application of heat to critical parts.

  16. STS-26 Pilot Covey floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Pilot Richard O. Covey, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. Covey pulls and fastens life raft protective cover over himself. The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle.

  17. The Scale Effect in Towing Tests with Airplane-float Systems

    NASA Technical Reports Server (NTRS)

    Schmidt, Rudolph

    1937-01-01

    The present report includes a description of the making of three-component measurements on a full-size float mounted on an actual airplane and the comparison of the results with those from two models of the same form but of different size which had been tested in the towing tank. The purpose of the comparison is to determine the effect of the Reynolds Number on the results of model tank tests. Following a brief discussion of previous tests intended to elucidate the problem of scale effect on float systems and a description of the testing equipment, the choice of the reference quantities to be used in the comparison is discussed. The selection of load, speed, and trim as a basis of comparison seems best suited to the practical operation of making this comparison. The quantities affected by scale are then: resistance, trimming moment, and their derivatives; planing number (resistance/weight on water); and position of center of pressure.

  18. N-body scattering. I. The algebraic structure of transition amplitude and integral equations (in Chinese)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pao, C.K.

    1975-05-01

    An assessment of wave energy as a source of electrical power in the United Kingdom is reported. British Hovercraft Corporation has conducted some tank tests for Wavepower Limited, studying various simple float systems. It aims to develop a wave-power device that is simple, cheap, made up of small mass- produced units, can be installed in sections, and can be easily maintained. A chain of floats, hinged together, with waves traveling down the chain, was investigated. Pumps on the hinges absorb power from the relative rotation of adjacent floats. A wave-power device could also serve as an effective breakwater. Direct generationmore » of electricity is a feasible application of wave power. The system is compared with a rocking boom concept. Wave energy could be used in conjunction with thermal stations to provide sufficient capacity when wave power is low. Wave power has a high availability when compared with wind power. (MCW)« less

  19. Biomechanics-based active control of bedding support properties and its influence on sleep.

    PubMed

    Van Deun, D; Verhaert, V; Willemen, T; Wuyts, J; Verbraecken, J; Exadaktylos, V; Haex, B; Vander Sloten, J

    2012-01-01

    Proper body support plays an import role in the recuperation of our body during sleep. Therefore, this study uses an automatically adapting bedding system that optimises spinal alignment throughout the night by altering the stiffness of eight comfort zones. The aim is to investigate the influence of such a dynamic sleep environment on objective and subjective sleep parameters. The bedding system contains 165 sensors that measure mattress indentation. It also includes eight actuators that control the comfort zones. Based on the measured mattress indentation, body movements and posture changes are detected. Control of spinal alignment is established by fitting personalized human models in the measured indentation. A total of 11 normal sleepers participated in this study. Sleep experiments were performed in a sleep laboratory where subjects slept three nights: a first night for adaptation, a reference night and an active support night (in counterbalanced order). Polysomnographic measurements were recorded during the nights, combined with questionnaires aiming at assessing subjective information. Subjective information on sleep quality, daytime quality and perceived number of awakenings shows significant improvements during the active support (ACS) night. Objective results showed a trend towards increased slow wave sleep. On the other hand, it was noticed that % N1-sleep was significantly increased during ACS night, while % N2-sleep was significantly decreased. No prolonged N1 periods were found during or immediately after steering.

  20. Lighting and perceptual cues: Effects on gait measures of older adults at high and low risk for falls

    PubMed Central

    2011-01-01

    Background The visual system plays an important role in maintaining balance. As a person ages, gait becomes slower and stride becomes shorter, especially in dimly lighted environments. Falls risk has been associated with reduced speed and increased gait variability. Methods Twenty-four older adults (half identified at risk for falls) experienced three lighting conditions: pathway illuminated by 1) general ceiling-mounted fixtures, 2) conventional plug-in night lights and 3) plug-in night lights supplemented by laser lines outlining the pathway. Gait measures were collected using the GAITRite© walkway system. Results Participants performed best under the general ceiling-mounted light system and worst under the night light alone. The pathway plus night lights increased gait velocity and reduced step length variability compared to the night lights alone in those at greater risk of falling. Conclusions Practically, when navigating in more challenging environments, such as in low-level ambient illumination, the addition of perceptual cues that define the horizontal walking plane can potentially reduce falls risks in older adults. PMID:21864387

  1. Causes, trends, and policy of population migration and the floating population.

    PubMed

    Cai, F

    1996-01-01

    This study provides a discussion of migration theory, a description of the main characteristics of migrants and floating population in China, and a migration impact assessment and potential social policy directions. It is argued that the impetus for migration in China was the population distribution pattern and an uneven industrial structure that favored heavy industry. Another factor affecting migration is the gap in income between urban and rural areas, which has widened since reforms in the mid-1980s. The author finds the Todaro or the Harris-Todaro theories inappropriate for understanding migration in developing countries and flawed. Evidence about migrants' characteristics suggest that migration in China was part of a process governed by the laws of economic growth and market development. Legal migrants are defined as those who legally migrated according to the household registration system. China's development strategy during the 1950s relied on growth of capital-intensive heavy industry. The cost was underwritten by adoption of a price system that shifted the price of products in order to lower the cost of heavy industrial development. During 1952-78, agricultural output dropped sharply, but the employment structure changed very little and the rate of urbanization changed slightly. Regional inequality was obvious by 1978. As reform progressed, patterns emerged that favored eastern coastal development. Microlevel reform outdistanced macrolevel reform. Obstacles to migration were reduced: the breakup of the commune system and changes in the urban food supply system and housing. In 1990 there were 34.128 million migrants, of which 32.42% were interprovincial and 42.99% involved job-related shifts. In 1992, 8.1% of urban population were not registered; 94.909 million were floating population. Cities have established policies to match the size of the floating population to the current carrying capacity.

  2. Limited evidence for affective and diurnal rhythm responses to dim light-at-night in male and female C57Bl/6 mice.

    PubMed

    Cleary-Gaffney, Michael; Coogan, Andrew N

    2018-05-15

    Circadian rhythms are recurring patterns in a range of behavioural, physiological and molecular parameters that display periods of near 24 h, and are underpinned by an endogenous biological timekeeping system. Circadian clocks are increasingly recognised as being key for health. Environmental light is the key stimulus that synchronises the internal circadian system with the external time cues. There are emergent health concerns regarding increasing worldwide prevalence of electric lighting, especially man-made light-at-night, and light's impact on the circadian system may be central to these effects. A number of previous studies have demonstrated increased depression-like behaviour in various rodent experimental models exposed to dim light-at-night. In this study we set out to study the impact of dim light-at-night on circadian and affective behaviours in C57Bl/6 mice. We set out specifically to examine the impact of sex on light at night's effects, as well as the impact of housing conditions. We report minimal impact of light-at-night on circadian and affective behaviours, as measured by the tail suspension test, the forced swim test, the sucrose preference test and the elevated plus maze. Light-at-night was also not associated with an increase in body weight, but was associated with a decrease in the cell proliferation marker Ki-67 in the dentate gyrus. In summary, we conclude that experimental contextual factors, such as model species or strain, may be considerable importance in the investigation of the impact of light at night on mood-related parameters. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Wireless telemetry system for floating bodies

    NASA Technical Reports Server (NTRS)

    Fain, L. T.; Cribb, H. E.

    1974-01-01

    Unit includes rugged waterproof cables and equipment containers, low power, sturdy antenna construction, and easy equipment setup and serviceability. Accuracy and reliability of entire measurement system were not sacrificed.

  4. Multi-channel automotive night vision system

    NASA Astrophysics Data System (ADS)

    Lu, Gang; Wang, Li-jun; Zhang, Yi

    2013-09-01

    A four-channel automotive night vision system is designed and developed .It is consist of the four active near-infrared cameras and an Mulit-channel image processing display unit,cameras were placed in the automobile front, left, right and rear of the system .The system uses near-infrared laser light source,the laser light beam is collimated, the light source contains a thermoelectric cooler (TEC),It can be synchronized with the camera focusing, also has an automatic light intensity adjustment, and thus can ensure the image quality. The principle of composition of the system is description in detail,on this basis, beam collimation,the LD driving and LD temperature control of near-infrared laser light source,four-channel image processing display are discussed.The system can be used in driver assistance, car BLIS, car parking assist system and car alarm system in day and night.

  5. DSS 13 Microprocessor Antenna Controller

    NASA Technical Reports Server (NTRS)

    Gosline, R. M.

    1984-01-01

    A microprocessor based antenna controller system developed as part of the unattended station project for DSS 13 is described. Both the hardware and software top level designs are presented and the major problems encounted are discussed. Developments useful to related projects include a JPL standard 15 line interface using a single board computer, a general purpose parser, a fast floating point to ASCII conversion technique, and experience gained in using off board floating point processors with the 8080 CPU.

  6. Toward a formal verification of a floating-point coprocessor and its composition with a central processing unit

    NASA Technical Reports Server (NTRS)

    Pan, Jing; Levitt, Karl N.; Cohen, Gerald C.

    1991-01-01

    Discussed here is work to formally specify and verify a floating point coprocessor based on the MC68881. The HOL verification system developed at Cambridge University was used. The coprocessor consists of two independent units: the bus interface unit used to communicate with the cpu and the arithmetic processing unit used to perform the actual calculation. Reasoning about the interaction and synchronization among processes using higher order logic is demonstrated.

  7. Development of gastroretentive metronidazole floating raft system for targeting Helicobacter pylori.

    PubMed

    Abou Youssef, Nancy Abdel Hamid; Kassem, Abeer Ahmed; El-Massik, Magda Abd Elsamea; Boraie, Nabila Ahmed

    2015-01-01

    The study demonstrates the feasibility of prolonging gastric residence time and release rate of metronidazole (Mz) by preparing floating raft system (FRS) using ion-sensitive in situ gel forming polymers. FRSs contained 3, 4, 5 and 0.5, 0.75, 1% w/v sodium alginate (Alg) and gellan gum (G), respectively, 0.25% w/v sodium citrate and calcium carbonate (C). Lipids: glyceryl mono stearate (GMS), Precirol(®) and Compritol(®) were incorporated into G-based formulations (G1%C1%). Mz:lipid ratio was 1:1, except for Mz:GMS, ratios of 1:1.5 and 1:2 were also investigated. Buoyancy, gelation capacity and viscosity parameters were evaluated. Drug release and kinetics for selected formulae were examined. The selected lipid containing formula was subjected to an accelerated stability testing. Alg4%C2% FRS exhibited short gelation lag time (3s), long duration (>24h), floating lag time 1m in and duration >24h, and a reliable sustained drug release (MDT 6h). Gellan gum FRSs achieved successful floating gastroretention, but failed to achieve the required gelation capacity. Incorporation of GMS (Mz:GMS 1:1) enhanced the gelation lag time and duration (6s and >24h, respectively), keeping sustained drug release and formulation stability. The improved characteristics of the selected FRS make them excellent candidates for gastric targeting to eradicate Helicobacter pylori. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Design and Optimization of Floating Drug Delivery System of Acyclovir

    PubMed Central

    Kharia, A. A.; Hiremath, S. N.; Singhai, A. K.; Omray, L. K.; Jain, S. K.

    2010-01-01

    The purpose of the present work was to design and optimize floating drug delivery systems of acyclovir using psyllium husk and hydroxypropylmethylcellulose K4M as the polymers and sodium bicarbonate as a gas generating agent. The tablets were prepared by wet granulation method. A 32 full factorial design was used for optimization of drug release profile. The amount of psyllium husk (X1) and hydroxypropylmethylcellulose K4M (X2) were selected as independent variables. The times required for 50% (t50%) and 70% (t70%) drug dissolution were selected as dependent variables. All the designed nine batches of formulations were evaluated for hardness, friability, weight variation, drug content uniformity, swelling index, in vitro buoyancy, and in vitro drug release profile. All formulations had floating lag time below 3 min and constantly floated on dissolution medium for more than 24 h. Validity of the developed polynomial equation was verified by designing two check point formulations (C1 and C2). The closeness of predicted and observed values for t50% and t70% indicates validity of derived equations for the dependent variables. These studies indicated that the proper balance between psyllium husk and hydroxypropylmethylcellulose K4M can produce a drug dissolution profile similar to the predicted dissolution profile. The optimized formulations followed Higuchi's kinetics while the drug release mechanism was found to be anomalous type, controlled by diffusion through the swollen matrix. PMID:21694992

  9. Design and optimization of floating drug delivery system of acyclovir.

    PubMed

    Kharia, A A; Hiremath, S N; Singhai, A K; Omray, L K; Jain, S K

    2010-09-01

    The purpose of the present work was to design and optimize floating drug delivery systems of acyclovir using psyllium husk and hydroxypropylmethylcellulose K4M as the polymers and sodium bicarbonate as a gas generating agent. The tablets were prepared by wet granulation method. A 3(2) full factorial design was used for optimization of drug release profile. The amount of psyllium husk (X1) and hydroxypropylmethylcellulose K4M (X2) were selected as independent variables. The times required for 50% (t(50%)) and 70% (t(70%)) drug dissolution were selected as dependent variables. All the designed nine batches of formulations were evaluated for hardness, friability, weight variation, drug content uniformity, swelling index, in vitro buoyancy, and in vitro drug release profile. All formulations had floating lag time below 3 min and constantly floated on dissolution medium for more than 24 h. Validity of the developed polynomial equation was verified by designing two check point formulations (C1 and C2). The closeness of predicted and observed values for t(50%) and t(70%) indicates validity of derived equations for the dependent variables. These studies indicated that the proper balance between psyllium husk and hydroxypropylmethylcellulose K4M can produce a drug dissolution profile similar to the predicted dissolution profile. The optimized formulations followed Higuchi's kinetics while the drug release mechanism was found to be anomalous type, controlled by diffusion through the swollen matrix.

  10. Evaluation of visual acuity with Gen 3 night vision goggles

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur; Kaiser, Mary K.

    1994-01-01

    Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.

  11. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    NASA Astrophysics Data System (ADS)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady-state diffusion equation. For the in vitro experiments, floating reference positions exist in 1220 nm and 1320 nm under two types of light source, and the results are quite close. However, the reference positions obtained from experiments are further from the light source compared with those obtained in the MC simulation. For the turbid media and the wavelengths investigated, the difference is up to 1 mm. This study is important for the design of optical fibers to be applied in the floating reference measurement.

  12. Formulation, development, and evaluation of floating pulsatile drug delivery system of atenolol.

    PubMed

    Jagdale, Swati C; Sali, Monali S; Barhate, Ajay L; Kuchekar, Bhanudas S; Chabukswar, Aniruddha R

    2013-01-01

    The objective of this work was to develop and evaluate a floating-pulsatile drug delivery of atenolol. The floating-pulsatile concept was applied to increase the gastric residence of the dosage form by having lag phase followed by a burst release. The system was generated which consisted of three different parts: a core tablet, containing the active ingredient; an erodible outer shell; and a top cover buoyant layer. The dry, coated tablet consists in a drug-containing core, coated by a hydrophilic erodible polymer responsible for a lag phase in the onset of pulsatile release. The buoyant layer, prepared with hydroxypropyl methylcellulose (HPMC) K100 M, citric acid, and sodium bicarbonate, provides buoyancy to increase the retention of the oral dosage form in the stomach. The effect of the hydrophilic erodible polymer characteristics on the lag time and drug release was investigated. Developed formulations were evaluated for their physical properties in vitro release as well as in vivo behavior. The results showed that K3 (180 mg of HPMC K4 M) and K6 (290 mg of HPMC E15 LV) with a buoyant layer were the best formulation, with lag times of 5.2 ± 0.1 h and 4.1 ± 0.2 h, respectively. Floating time was controlled by the quantity and composition of the buoyant layer. In-vitro results point out the capability of the system with its prolonged residence of the tablets in the stomach and release of drug after a programmed lag time. This was confirmed by in vivo x-ray technique. The objective of the present work was to develop a floating-pulsatile oral drug delivery system of atenolol with addition of hydroxylpropyl methylcellulose (HPMC) K100 M, HPMC K4 M, and HPMC E15 LV in different ratios with citric acid and sodium bicarbonate as gas-forming agents. The system consist of three different parts: a core tablet, containing the active ingredient; a bottom layer that erodes; and a top cover floating layer. Atenolol, a β-blocker, is prescribed widely in diverse cardiovascular diseases, for example, hypertension, angina pectoris, arrhythmias, and myocardial infarction. Developed formulations were evaluated for their physical properties and vitro release as well as in vivo behavior. The results showed that K3 (180 mg HPMC K4 M) and K6 (290 mg of HPMC E15 LV) with a buoyant layer were the best formulations with the lag times of 5.2 ± 0.1 h and 4.1 ± 0.2 h, respectively, and were found to be the best choice for manufacturing tablets.

  13. Solids feeder apparatus

    DOEpatents

    Bell, Jr., Harold S.

    1979-01-01

    This invention sets forth a double-acting piston, which carries a floating piston, and which is reciprocated in a housing, for feeding coal to a high pressure gasifier system. The housing has a plurality of solids (for instance: coal) in-feeding ports and a single discharge port, the latter port being in communication with a high pressure gasifier system. The double-acting piston sequentially and individually communicates each of the in-feeding ports with the discharge port. The floating piston both seals off the discharge port while each in-feeding port is receiving coal or the like, to prevent undue escape of gas from the gasifier system, and translates in the housing, following a discharge of coal or the like into the discharge port, to return gas which has been admitted into the housing back into the gasifier system.

  14. Artificial light at night advances avian reproductive physiology

    PubMed Central

    Dominoni, Davide; Quetting, Michael; Partecke, Jesko

    2013-01-01

    Artificial light at night is a rapidly increasing phenomenon and it is presumed to have global implications. Light at night has been associated with health problems in humans as a consequence of altered biological rhythms. Effects on wild animals have been less investigated, but light at night has often been assumed to affect seasonal cycles of urban dwellers. Using light loggers attached to free-living European blackbirds (Turdus merula), we first measured light intensity at night which forest and city birds are subjected to in the wild. Then we used these measurements to test for the effect of light at night on timing of reproductive physiology. Captive city and forest blackbirds were exposed to either dark nights or very low light intensities at night (0.3 lux). Birds exposed to light at night developed their reproductive system up to one month earlier, and also moulted earlier, than birds kept under dark nights. Furthermore, city birds responded differently than forest individuals to the light at night treatment, suggesting that urbanization can alter the physiological phenotype of songbirds. Our results emphasize the impact of human-induced lighting on the ecology of millions of animals living in cities and call for an understanding of the fitness consequences of light pollution. PMID:23407836

  15. Multi-level Capacitive Memory Effect in Metal/Oxide/Floating-Schottky Junction

    NASA Astrophysics Data System (ADS)

    Choi, Gahyun; Jung, Sungchul; Yoon, Hoon Hahn; Jeon, Youngeun; Park*, Kibog

    2015-03-01

    A memory computing (memcomputing) system can store and process information at the same physical location simultaneously. The essential components of memcomputing are passive devices with memory functionality, such as memristor, memcapacitor, and meminductor. We report the realization of a Schottky contact memcapacitor compatible with the current Si CMOS technology. Our memcapacitor is formed by depositing a stack of metal and oxide thin films on top of a Schottky contact. Here, the metal electrode of the Schottky contact is floating. The working principle of our memcapacitor is based on the fact that the depletion width of the Schottky contact varies according to the amount of charge stored in the floating metal electrode. The voltage pulse applied across the Metal/Oxide/Floating-Schottky junction controls charge flow in the Schottky contact and determines the amount of charge stored eventually. It is demonstrated experimentally that our memcapacitor exhibits hysteresis behaviors in capacitance-voltage curves and possesses multiple capacitance values that are switchable by the applied voltage pulse. Supported by NRF in South Korea (2013R1A1A2007070).

  16. Floating-to-Fixed-Point Conversion for Digital Signal Processors

    NASA Astrophysics Data System (ADS)

    Menard, Daniel; Chillet, Daniel; Sentieys, Olivier

    2006-12-01

    Digital signal processing applications are specified with floating-point data types but they are usually implemented in embedded systems with fixed-point arithmetic to minimise cost and power consumption. Thus, methodologies which establish automatically the fixed-point specification are required to reduce the application time-to-market. In this paper, a new methodology for the floating-to-fixed point conversion is proposed for software implementations. The aim of our approach is to determine the fixed-point specification which minimises the code execution time for a given accuracy constraint. Compared to previous methodologies, our approach takes into account the DSP architecture to optimise the fixed-point formats and the floating-to-fixed-point conversion process is coupled with the code generation process. The fixed-point data types and the position of the scaling operations are optimised to reduce the code execution time. To evaluate the fixed-point computation accuracy, an analytical approach is used to reduce the optimisation time compared to the existing methods based on simulation. The methodology stages are described and several experiment results are presented to underline the efficiency of this approach.

  17. Current-Voltage and Floating-Potential characteristics of cylindrical emissive probes from a full-kinetic model based on the orbital motion theory

    NASA Astrophysics Data System (ADS)

    Chen, Xin; Sánchez-Arriaga, Gonzalo

    2018-02-01

    To model the sheath structure around an emissive probe with cylindrical geometry, the Orbital-Motion theory takes advantage of three conserved quantities (distribution function, transverse energy, and angular momentum) to transform the stationary Vlasov-Poisson system into a single integro-differential equation. For a stationary collisionless unmagnetized plasma, this equation describes self-consistently the probe characteristics. By solving such an equation numerically, parametric analyses for the current-voltage (IV) and floating-potential (FP) characteristics can be performed, which show that: (a) for strong emission, the space-charge effects increase with probe radius; (b) the probe can float at a positive potential relative to the plasma; (c) a smaller probe radius is preferred for the FP method to determine the plasma potential; (d) the work function of the emitting material and the plasma-ion properties do not influence the reliability of the floating-potential method. Analytical analysis demonstrates that the inflection point of an IV curve for non-emitting probes occurs at the plasma potential. The flat potential is not a self-consistent solution for emissive probes.

  18. MS Peterson and MS Musgrave in payload bay (PLB) during EVA

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Extravehicular mobility unit (EMU) suited Mission Specialist (MS) Peterson, designated EV2, translates from forward payload bay (PLB) to aft bulkhead worksite along port side sill longeron using tether and slidewire system while MS Musgrave, designated EV1, floats on a tether in center of PLB. Inertial Upper Stage (IUS) Airborne Support Equipment (ASE) forward frame and aft frame tilt actuator (AFTA) table appear in front and behind Musgrave and vertical tail and Orbital Maneuvering System (OMS) pods appear in background highlighted against the cloudy surface of Earth. EMU mini workstation extravehicular activity (EVA) crewmember safety tether reel floats on Musgrave's waist tether.

  19. Screening of 18 species for digestate phytodepuration.

    PubMed

    Pavan, Francesca; Breschigliaro, Simone; Borin, Maurizio

    2015-02-01

    This experiment assesses the aptitude of 18 species in treating the digestate liquid fraction (DLF) in a floating wetland treatment system. The pilot system was created in NE Italy in 2010 and consists of a surface-flow system with 180 floating elements (Tech-IA®) vegetated with ten halophytes and eight other wetland species. The species were transplanted in July 2011 in basins filled with different proportions of DLF/water (DLF/w); periodic increasing of the DLF/w ratio was imposed after transplanting, reaching the worst conditions for plants in summer 2012 (highest EC value 7.3 mS cm/L and NH4-N content 225 mg/L). It emerged that only Cynodon dactylon, Typha latifolia, Elytrigia atherica, Halimione portulacoides, Salicornia fruticosa, Artemisia caerulescens, Spartina maritima and Puccinellia palustris were able to survive under the system conditions. Halophytes showed higher dry matter production than other plants. The best root development (up to 40-cm depth) was recorded for Calamagrostis epigejos, Phragmites australis, T. latifolia and Juncus maritimus. The highest nitrogen (10-15 g/m(2)) and phosphorus (1-4 g/m(2)) uptakes were obtained with P. palustris, Iris pseudacorus and Aster tripolium. In conclusion, two halophytes, P. palustris and E. atherica, present the highest potential to be used to treat DLF in floating wetlands.

  20. Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer.

    PubMed

    Böhnke, Frank; Bretan, Theodor; Lehner, Stefan; Strenger, Tobias

    2013-10-22

    The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer) is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from μ-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.

  1. Floating modular drug delivery systems with buoyancy independent of release mechanisms to sustain amoxicillin and clarithromycin intra-gastric concentrations.

    PubMed

    Rossi, Alessandra; Conti, Chiara; Colombo, Gaia; Castrati, Luca; Scarpignato, Carmelo; Barata, Pedro; Sandri, Giuseppina; Caramella, Carla; Bettini, Ruggero; Buttini, Francesca; Colombo, Paolo

    2016-01-01

    Release modules of amoxicillin and clarithromycin combined in a single dosage form designed to float in the gastric content and to sustain the intra-gastric concentrations of these two antibiotics used for the eradication of Helicobacter pylori have been studied. The modules having a disc shape with curved bases were formulated as hydrophilic matrices. Two modules of clarithromycin were assembled by sticking the concave base of one module to the concave base of the other, creating an internal void chamber. The final dosage form was a floating assembly of three modules of clarithromycin and two of amoxicillin in which the drug release mechanism did not interfere with the floatation mechanism. The assembled system showed immediate in vitro floatation at pH 1.2, lasting 5 h. The in vitro antibiotics release profiles from individual modules and assembled systems exhibited linear release rate during buoyancy for at least 8 h. The predicted antibiotic concentrations in the stomach maintained for long time levels significantly higher than the respective minimum inhibitory concentrations (MIC). In addition, an in vivo absorption study performed on beagle dogs confirmed the slow release of clarithromycin and amoxicillin from the assembled system during the assembly's permanence in the stomach for at least 4 h.

  2. Sleep and autonomic nervous system changes - enhanced cardiac sympathetic modulations during sleep in permanent night shift nurses.

    PubMed

    Chung, Min-Huey; Kuo, Terry B J; Hsu, Nanly; Chu, Hsin; Chou, Kuei-Ru; Yang, Cheryl C H

    2009-05-01

    Disturbed sleep is the most common problem among the many health-related effects of shift work, with shift workers clearly having higher rates of cardiac disorders. However, the possible mechanism underlying the related health effects of shift work has yet to be examined. Consequently, this study aimed to explore the influence of long-term night shift work on the sleep patterns of nurses and their cardiac autonomic nervous system during sleep. Our sample comprised ten permanent night shift and ten regular morning shift nurses. Nurses slept in their dormitory where they were allowed to sleep and wake spontaneously. All sleep parameters were digitized using an ambulatory polysomnographic recorder. Using sleep patterns and heart rate variability, the day- and nighttime sleep of permanent night shift nurses were compared with the nighttime sleep of regular morning shift nurses. Compared with the nighttime sleep of regular morning shift nurses, the pattern of daytime sleep of permanent night shift nurses showed significantly lower sleep onset latency. Permanent night shift nurses' daytime sleep also had greater proportions of Stage 3 and 4 (deep sleep), and arousal index than recorded during their nighttime sleep. Both the low frequency and low to high frequency ratio of the nighttime sleep of night shift nurses were significantly higher during periods of non-rapid eye movement (NREM) sleep than the nighttime sleep of morning shift workers. In addition, the electroencephalography delta-power of the nighttime sleep of night shift nurses was significantly lower during the first NREM episode sleep than those of both the daytime sleep of night shift workers and the nighttime sleep of morning shift nurses. Permanent night shift nurses have higher sympathetic activity during nighttime sleep than regular morning shift nurses. Night shift working may have effects on the sleeping patterns of nurses in the long run, inducing higher cardiac sympathetic regulation.

  3. [Dark matter and dark energy of the universe].

    PubMed

    Aguilar Peris, José

    2005-01-01

    At the turn of the 20th Century, the Universe was thought to consist of our solar system, the Sun, planets, satellites and comets, floating under the Milky Way. The astronomers were ignorant of the existence of galaxies, clusters, quasars and black holes. Over the last ten years the Cosmology has made remarkable progress in our understanding of the composition of the Universe: 23 per cent is in an unknown form called dark matter; 73 per cent in another form called dark energy; 3 per cent is made of free hydrogen and helium atoms; 0.5 per cent makes up all the light we see in the night including the stars, clusters and superclusters; 0.3 per cent is in free neutrino particles; and finally, 0.03 per cent is in the heavier nuclei of which the Sun, the Earth and ourselves are made. In this work we study specially the dark matter and the dark energy. The first one appears to be attached to galaxies, and astronomers agree that it is cold, meaning that the particles that make up that matter are not moving fast. Very recently astronomers discovered that a tremendous amount of the so-cahled dark energy exists and that it is pushing and accelerating the expansion of the Universe. Should this expansion continue for another 14,000 million years, the sky will darken with only a handful of galaxies remaining visible.

  4. 33 CFR 144.01-1 - Life floats.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Life floats. 144.01-1 Section 144... CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-1 Life floats. Each manned platform shall be provided with at least two approved life floats. The life floats shall have sufficient...

  5. 46 CFR 160.027-3 - Additional requirements for life floats.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Additional requirements for life floats. 160.027-3..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Life Floats for Merchant Vessels § 160.027-3 Additional requirements for life floats. (a) Each life float must have a platform designed...

  6. 46 CFR 160.027-3 - Additional requirements for life floats.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Additional requirements for life floats. 160.027-3..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Life Floats for Merchant Vessels § 160.027-3 Additional requirements for life floats. (a) Each life float must have a platform designed...

  7. 33 CFR 144.01-1 - Life floats.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Life floats. 144.01-1 Section 144... CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-1 Life floats. Each manned platform shall be provided with at least two approved life floats. The life floats shall have sufficient...

  8. 14 CFR 29.757 - Hull and auxiliary float strength.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and auxiliary float strength. 29.757... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Floats and Hulls § 29.757 Hull and auxiliary float strength. The hull, and auxiliary floats if used, must withstand the...

  9. 33 CFR 144.01-1 - Life floats.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Life floats. 144.01-1 Section 144... CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-1 Life floats. Each manned platform shall be provided with at least two approved life floats. The life floats shall have sufficient...

  10. 33 CFR 144.01-1 - Life floats.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Life floats. 144.01-1 Section 144... CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-1 Life floats. Each manned platform shall be provided with at least two approved life floats. The life floats shall have sufficient...

  11. 33 CFR 144.01-1 - Life floats.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Life floats. 144.01-1 Section 144... CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-1 Life floats. Each manned platform shall be provided with at least two approved life floats. The life floats shall have sufficient...

  12. 46 CFR 160.027-3 - Additional requirements for life floats.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Additional requirements for life floats. 160.027-3..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Life Floats for Merchant Vessels § 160.027-3 Additional requirements for life floats. (a) Each life float must have a platform designed...

  13. 46 CFR 160.027-3 - Additional requirements for life floats.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Additional requirements for life floats. 160.027-3..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Life Floats for Merchant Vessels § 160.027-3 Additional requirements for life floats. (a) Each life float must have a platform designed...

  14. 46 CFR 160.027-3 - Additional requirements for life floats.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Additional requirements for life floats. 160.027-3..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Life Floats for Merchant Vessels § 160.027-3 Additional requirements for life floats. (a) Each life float must have a platform designed...

  15. Load assumptions for the landing impact of seaplanes

    NASA Technical Reports Server (NTRS)

    Taub, Josef

    1931-01-01

    The formula for the impact of floats must include the enlargement factor itself as well as the type of enlargement. The latter is preferably characterized by the change in surface loading. It is shown that the enlargement of a small seaplane generally results in a changed float (or boat) loading as well as wing loading. The conditions of starting stipulate the retention of the float loading when changing from single-float (boat) to twin-float arrangement. This contingency is followed by an increased impact factor in the twin-float type against the otherwise equivalent single-float type.

  16. Vegetation, substrate and hydrology in floating marshes in the Mississippi river delta plain wetlands, USA

    USGS Publications Warehouse

    Sasser, C.E.; Gosselink, J.G.; Swenson, E.M.; Swarzenski, C.M.; Leibowitz, N.C.

    1996-01-01

    In the 1940s extensive floating marshes (locally called 'flotant') were reported and mapped in coastal wetlands of the Mississippi River Delta Plain. These floating marshes included large areas of Panicum hemitomon-dominated freshwater marshes, and Spartina patens/Scirpus olneyi brackish marshes. Today these marshes appear to be quite different in extent and type. We describe five floating habitats and one non-floating, quaking habitat based on differences in buoyancy dynamics (timing and degree of floating), substrate characteristics, and dominant vegetation. All floating marshes have low bulk density, organic substrates. Nearly all are fresh marshes. Panicum hemitomon floating marshes presently occur within the general regions that were reported in the 1940's by O'Neil, but are reduced in extent. Some of the former Panicum hemitomon marshes have been replaced by seasonally or variably floating marshes dominated, or co-dominated by Sagittaria lancifolia or Eleocharis baldwinii. ?? 1996 Kluwer Academic Publishers.

  17. A Retina-Like Dual Band Organic Photosensor Array for Filter-Free Near-Infrared-to-Memory Operations.

    PubMed

    Wang, Hanlin; Liu, Hongtao; Zhao, Qiang; Ni, Zhenjie; Zou, Ye; Yang, Jie; Wang, Lifeng; Sun, Yanqiu; Guo, Yunlong; Hu, Wenping; Liu, Yunqi

    2017-08-01

    Human eyes use retina photoreceptor cells to absorb and distinguish photons from different wavelengths to construct an image. Mimicry of such a process and extension of its spectral response into the near-infrared (NIR) is indispensable for night surveillance, retinal prosthetics, and medical imaging applications. Currently, NIR organic photosensors demand optical filters to reduce visible interference, thus making filter-free and anti-visible NIR imaging a challenging task. To solve this limitation, a filter-free and conformal, retina-inspired NIR organic photosensor is presented. Featuring an integration of photosensing and floating-gate memory modules, the device possesses an acute color distinguishing capability. In general, the retina-like photosensor transduces NIR (850 nm) into nonvolatile memory and acts as a dynamic photoswitch under green light (550 nm). In doing this, a filter-free but color-distinguishing photosensor is demonstrated that selectively converts NIR optical signals into nonvolatile memory. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. The Discovery and Mass Measurement of a New Ultra-short-period Planet: K2-131b

    NASA Astrophysics Data System (ADS)

    Dai, Fei; Winn, Joshua N.; Gandolfi, Davide; Wang, Sharon X.; Teske, Johanna K.; Burt, Jennifer; Albrecht, Simon; Barragán, Oscar; Cochran, William D.; Endl, Michael; Fridlund, Malcolm; Hatzes, Artie P.; Hirano, Teruyuki; Hirsch, Lea A.; Johnson, Marshall C.; Justesen, Anders Bo; Livingston, John; Persson, Carina M.; Prieto-Arranz, Jorge; Vanderburg, Andrew; Alonso, Roi; Antoniciello, Giuliano; Arriagada, Pamela; Butler, R. P.; Cabrera, Juan; Crane, Jeffrey D.; Cusano, Felice; Csizmadia, Szilárd; Deeg, Hans; Dieterich, Sergio B.; Eigmüller, Philipp; Erikson, Anders; Everett, Mark E.; Fukui, Akihiko; Grziwa, Sascha; Guenther, Eike W.; Henry, Gregory W.; Howell, Steve B.; Johnson, John Asher; Korth, Judith; Kuzuhara, Masayuki; Narita, Norio; Nespral, David; Nowak, Grzegorz; Palle, Enric; Pätzold, Martin; Rauer, Heike; Montañés Rodríguez, Pilar; Shectman, Stephen A.; Smith, Alexis M. S.; Thompson, Ian B.; Van Eylen, Vincent; Williamson, Michael W.; Wittenmyer, Robert A.

    2017-12-01

    We report the discovery of a new ultra-short-period planet and summarize the properties of all such planets for which the mass and radius have been measured. The new planet, K2-131b, was discovered in K2 Campaign 10. It has a radius of {1.81}-0.12+0.16 {R}\\oplus and orbits a G dwarf with a period of 8.9 hr. Radial velocities obtained with Magellan/PFS and TNG/HARPS-N show evidence for stellar activity along with orbital motion. We determined the planetary mass using two different methods: (1) the “floating chunk offset” method, based only on changes in velocity observed on the same night; and (2) a Gaussian process regression based on both the radial velocity and photometric time series. The results are consistent and lead to a mass measurement of 6.5+/- 1.6 {M}\\oplus and a mean density of {6.0}-2.7+3.0 g cm-3.

  19. Why things go bump in the night

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, D.E.

    1996-09-01

    Visual processing leads to false security. Professor Emeritus Herschel W. Leibowitz of Pennsylvania State University pointed out some important facts about night-time navigation-vehicular or other - in a 1995 Distinguished Scientific Award Address, printed last spring in American Psychologist. People are often more tired at night. If they are working overtime or doing shift work, their systems are probably off-kilter. Unquestionably, they cannot see as well at night-night myopia has been investigated since the 18th century. The problem is this: with those factors so obvious, why do people fail to compensate for them by changing their driving habits enough tomore » balance out the risks? First, researchers poking around in, among other places, the brains of hamsters, discovered that there are two functionally separate visual processing systems. The orientation and guidance system is much less sensitive to the amount of light than is the focal systems; the latter is the system with which we recognize objects. That means a worker can securely find his or her way to the substation entrance form the parking lot, despite low light, but can easily stumble in an unexpected pot-hole on the way. Or a driver can stick to his lane, with the familiar help of feedback from the steering wheel, but be too slow to identify objects in the road.« less

  20. Low levels of serum total antioxidant capacity and presence at admission and absence at discharge of a day/night change as a marker of acute paranoid schizophrenia relapse.

    PubMed

    Morera-Fumero, Armando L; Díaz-Mesa, Estefanía; Abreu-Gonzalez, Pedro; Fernandez-Lopez, Lourdes; Cejas-Mendez, Maria Del Rosario

    2017-03-01

    An oxidant-antioxidant system dysregulation has been described as a schizophrenia pathophysiological base. The total antioxidant capacity (TAC) is one measure of the antioxidant capacity of a system. Day/night concentration changes is a biological characteristic of hormones such as melatonin or cortisol. There is no information about TAC day/night changes in schizophrenia. Studying the existence of a day/night TAC change in schizophrenia. Forty-three DSM-IV paranoid schizophrenia inpatients participated in the study. Thirty healthy subjects matched by age and gender acted as control group. Blood was sampled at 12:00 and 00:00h the day after admission and the day before discharge. Serum TAC was measured by the ABTS radical cation technique and expressed in Trolox mmol/L. Patients had significantly lower TAC levels at admission and discharge (12:00 and 00:00) than controls. At admission patients had a TAC day/night change, with higher day-time than night-time levels (0.66±0.14 vs 0.60±0.15) as well as healthy subjects (0.83±0.07 vs 0.77±0.11). At discharge patients had a similar TAC level at 12:00 and 00:00 (0.64±0.15 vs 0.63±0.14). Schizophrenic patients present a deficit of the antioxidant system. The initial presence and the later absence of a day/night change deserves future studies. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. The Euro-Argo education web site: using Argo data to teach data analysis and marine science

    NASA Astrophysics Data System (ADS)

    Byfield, Valborg; Scheurle, Carolyn; Gould, John; Macama, Emina; King, Brian

    2013-04-01

    The Euro-Argo education website (www.euroargo-edu.org) aims to make Argo and its data accessible to a non-specialist audience. The site is centred on a selection of floats, which have been chosen because of the insight they provide into key oceanographic processes, the physical and biogeochemical characteristics of different ocean regions around the world, and the role of the ocean in the global climate system. The float selection is a vehicle for teaching data analysis skills, linking these to current topics in the ocean and climate sciences. Each float in the selection has its own page, which provides access to the float data, data plots, background information on the ocean region in which the float can be found, and questions to guide data interpretation. Hidden 'model answers' allow users to check their understanding by comparing their own answers to those provided. The interactive component of the site also includes a series of quizzes, designed to teach data interpretation skills. These start at a basic level and take the students step by step through the most common ways to plot oceanographic data in space and time. More general background information covers the main aspects of the Argo programme, its history and applications, and basic technical information about the floats and sensors. 'World Tour' pages linked to the float selection provide information about the main ocean regions and link information from the Argo programme to oceanographic information from other sources such as satellite observations. The site is primarily aimed at young people between 11 and 18 years of age. However experience from using selected material from the site during science open days shows that children as young as 8-9 and adults of all ages also enjoy the challenge of using and interpreting the Argo data in different contexts.

  2. Electrically floating, near vertical incidence, skywave antenna

    DOEpatents

    Anderson, Allen A.; Kaser, Timothy G.; Tremblay, Paul A.; Mays, Belva L.

    2014-07-08

    An Electrically Floating, Near Vertical Incidence, Skywave (NVIS) Antenna comprising an antenna element, a floating ground element, and a grounding element. At least part of said floating ground element is positioned between said antenna element and said grounding element. The antenna is separated from the floating ground element and the grounding element by one or more electrical insulators. The floating ground element is separated from said antenna and said grounding element by one or more electrical insulators.

  3. Numerical modeling of a spherical buoy moored by a cable in three dimensions

    NASA Astrophysics Data System (ADS)

    Zhu, Xiangqian; Yoo, Wan-Suk

    2016-05-01

    Floating facilities have been studied based on the static analysis of mooring cables over the past decades. To analyze the floating system of a spherical buoy moored by a cable with a higher accuracy than before, the dynamics of the cables are considered in the construction of the numerical modeling. The cable modeling is established based on a new element frame through which the hydrodynamic loads are expressed efficiently. The accuracy of the cable modeling is verified with an experiment that is conducted by a catenary chain moving in a water tank. In addition, the modeling of a spherical buoy is established with respect to a spherical coordinate in three dimensions, which can suffers the gravity, the variable buoyancy and Froude-Krylov loads. Finally, the numerical modeling for the system of a spherical buoy moored by a cable is established, and a virtual simulation is proceeded with the X- and Y-directional linear waves and the X-directional current. The comparison with the commercial simulation code ProteusDS indicates that the system is accurately analyzed by the numerical modeling. The tensions within the cable, the motions of the system, and the relationship between the motions and waves are illustrated according to the defined sea state. The dynamics of the cables should be considered in analyzing the floating system of a spherical buoy moored by a cable.

  4. Atmospheric Modeling And Sensor Simulation (AMASS) study

    NASA Technical Reports Server (NTRS)

    Parker, K. G.

    1984-01-01

    The capabilities of the atmospheric modeling and sensor simulation (AMASS) system were studied in order to enhance them. This system is used in processing atmospheric measurements which are utilized in the evaluation of sensor performance, conducting design-concept simulation studies, and also in the modeling of the physical and dynamical nature of atmospheric processes. The study tasks proposed in order to both enhance the AMASS system utilization and to integrate the AMASS system with other existing equipment to facilitate the analysis of data for modeling and image processing are enumerated. The following array processors were evaluated for anticipated effectiveness and/or improvements in throughput by attachment of the device to the P-e: (1) Floating Point Systems AP-120B; (2) Floating Point Systems 5000; (3) CSP, Inc. MAP-400; (4) Analogic AP500; (5) Numerix MARS-432; and (6) Star Technologies, Inc. ST-100.

  5. 14 CFR 23.753 - Main float design.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Main float design. 23.753 Section 23.753... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Floats and Hulls § 23.753 Main float design. Each seaplane main float must meet the requirements of § 23.521. [Doc...

  6. General Classification Handbook for Floodplain Vegetation in Large River Systems. Chapter 1 of Book 2, Collection of Environmental Data

    DTIC Science & Technology

    2004-01-01

    chlorophyll content, and the more vigorous the growth , the greater the reflectance. This helps the photointerpreter to better distinguish between plant and...land cover map and the field determinations for each class. Based on the error matrix, the accuracy rate for classifying each map class can be...duck- weed (Lemna, Spirodela, and Wolffia) and other nonrooted- floating aquatics. Because duckweed is free-floating, it can relocate day-to-day

  7. On the effects of basic platform design characteristics on floating offshore wind turbine control and their mitigation

    NASA Astrophysics Data System (ADS)

    Olondriz, Joannes; Elorza, Iker; Trojaola, Ignacio; Pujana, Aron; Landaluze, Joseba

    2016-09-01

    Semi-submersible floating offshore wind turbines present significant advantages over other designs in terms of cost, deployment, maintenance and site-independence. However, these advantages are achieved by shifting a part of the burden of stabilising the platform pitch and roll motions to the turbine control system. A study is presented here of the effects of basic platform dimensions on the performance of a standard pitch controller and the possible methods for mitigating said effects.

  8. Low vibration laboratory with a single-stage vibration isolation for microscopy applications.

    PubMed

    Voigtländer, Bert; Coenen, Peter; Cherepanov, Vasily; Borgens, Peter; Duden, Thomas; Tautz, F Stefan

    2017-02-01

    The construction and the vibrational performance of a low vibration laboratory for microscopy applications comprising a 100 ton floating foundation supported by passive pneumatic isolators (air springs), which rest themselves on a 200 ton solid base plate, are discussed. The optimization of the air spring system leads to a vibration level on the floating floor below that induced by an acceleration of 10 ng for most frequencies. Additional acoustic and electromagnetic isolation is accomplished by a room-in-room concept.

  9. FLOAT OPERATED RADIAL GATE INSTALLATION. WASTEWAY NO. 1. WELLTONMOHAWK CANAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOAT OPERATED RADIAL GATE INSTALLATION. WASTEWAY NO. 1. WELLTON-MOHAWK CANAL - STA. 99+23.50. United States Department of the Interior, Bureau of Reclamation; Gila Project, Arizona, Wellton-Mohawk Division. Drawing No. 50-D-2497, dated March 8, 1949, Denver Colorado. Sheet 1 of 7 - Wellton-Mohawk Irrigation System, Wasteway No. 1, Wellton-Mohawk Canal, North side of Wellton-Mohawk Canal, bounded by Gila River to North & the Union Pacific Railroad & Gila Mountains to south, Wellton, Yuma County, AZ

  10. FLOAT OPERATED RADIAL GATE HOIST ASSEMBLY LIST OF PARTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOAT OPERATED RADIAL GATE HOIST ASSEMBLY - LIST OF PARTS - BASE-CRANK. WASTEWAY NO. 1. WELLTON-MOHAWK CANAL - STA. 99+23.50. United States Department of the Interior, Bureau of Reclamation; Gila Project, Arizona, Wellton-Mohawk Division. Drawing No. 50-D-2511, dated May 3, 1949, Denver Colorado. Sheet 1 of 2 - Wellton-Mohawk Irrigation System, Wasteway No. 1, Wellton-Mohawk Canal, North side of Wellton-Mohawk Canal, bounded by Gila River to North & the Union Pacific Railroad & Gila Mountains to south, Wellton, Yuma County, AZ

  11. Floating-point function generation routines for 16-bit microcomputers

    NASA Technical Reports Server (NTRS)

    Mackin, M. A.; Soeder, J. F.

    1984-01-01

    Several computer subroutines have been developed that interpolate three types of nonanalytic functions: univariate, bivariate, and map. The routines use data in floating-point form. However, because they are written for use on a 16-bit Intel 8086 system with an 8087 mathematical coprocessor, they execute as fast as routines using data in scaled integer form. Although all of the routines are written in assembly language, they have been implemented in a modular fashion so as to facilitate their use with high-level languages.

  12. STS-26 MS Hilmers floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) David C. Hilmers, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. Hilmers pulls his legs into the inflating raft while he is assisted by two SCUBA-equipped divers. The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle.

  13. STS-26 Commander Hauck floats in life raft during JSC WETF exercises

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, Commander Frederick H. Hauck, wearing the newly designed launch and entry suit (LES), floats in single-occupant life raft in JSC Weightless Environment Training Facility (WETF) Bldg 29 pool. Removing water from his raft, Hauck awaits the assistance of SCUBA-equipped divers (one of whom is partially visible at bottom right). The simulation of the escape and rescue operations utilized the crew escape system (CES) pole method of egress from the Space Shuttle.

  14. Control of free-flying space robot manipulator systems

    NASA Technical Reports Server (NTRS)

    Cannon, Robert H., Jr.

    1988-01-01

    The focus of the work is to develop and perform a set of research projects using laboratory models of satellite robots. These devices use air cushion technology to simulate in two dimensions the drag-free, zero-g conditions of space. Five research areas are examined: cooperative manipulation on a fixed base; cooperative manipulation on a free-floating base; global navigation and control of a free-floating robot; an alternative transport mode call Locomotion Enhancement via Arm Push-Off (LEAP), and adaptive control of LEAP.

  15. Flying helicopters over mountains at night...guidance systems tested in 1965 phase of study

    Treesearch

    Ralph G. Johnston; Cal Ferris; James B. Davis

    1966-01-01

    Under conditions simulating fireline operations, 117 helicopter flights were made at night over mountain areas in southern California. The trials indicated that such flights, carrying passengers and cargo, can be made safely if (a) the night operation is well planned, (b) the helicopter is in excellent condition, (c) adequate lighting and guidance equipment are...

  16. Interim-Night Integrated Goggle Head Tracking System (I-Nights). Volume 2. Flight Test, Pilot Survey Report

    DTIC Science & Technology

    1992-08-01

    instruments and the exterior environment with frequent shifts from one to the other. The design for future helmets should include the capability to switch...where and after how long? (20) I.A. 18 Did you experience any helmet temperature build-up? If YES, after how long? (21) I.A. 19 BATERY PACK (26) I.A. 19.a...three I-NIGHTS helmet mdels in the special .operations environment . 2. Critical Operational Issues for this 017T&H were: a. Do any of the I-NIGHTS

  17. Turbine with radial acting seal

    DOEpatents

    Eng, Darryl S; Ebert, Todd A

    2016-11-22

    A floating brush seal in a rim cavity of a turbine in a gas turbine engine, where the floating brush seal includes a seal holder in which the floating brush seal floats, and a expandable seal that fits within two radial extending seal slots that maintains a seal with radial displacement of the floating brush seal and the seal holder.

  18. Measuring noise equivalent irradiance of a digital short-wave infrared imaging system using a broadband source to simulate the night spectrum

    NASA Astrophysics Data System (ADS)

    Green, John R.; Robinson, Timothy

    2015-05-01

    There is a growing interest in developing helmet-mounted digital imaging systems (HMDIS) for integration into military aircraft cockpits. This interest stems from the multiple advantages of digital vs. analog imaging such as image fusion from multiple sensors, data processing to enhance the image contrast, superposition of non-imaging data over the image, and sending images to remote location for analysis. There are several properties an HMDIS must have in order to aid the pilot during night operations. In addition to the resolution, image refresh rate, dynamic range, and sensor uniformity over the entire Focal Plane Array (FPA); the imaging system must have the sensitivity to detect the limited night light available filtered through cockpit transparencies. Digital sensor sensitivity is generally measured monochromatically using a laser with a wavelength near the peak detector quantum efficiency, and is generally reported as either the Noise Equivalent Power (NEP) or Noise Equivalent Irradiance (NEI). This paper proposes a test system that measures NEI of Short-Wave Infrared (SWIR) digital imaging systems using a broadband source that simulates the night spectrum. This method has a few advantages over a monochromatic method. Namely, the test conditions provide spectrum closer to what is experienced by the end-user, and the resulting NEI may be compared directly to modeled night glow irradiance calculation. This comparison may be used to assess the Technology Readiness Level of the imaging system for the application. The test system is being developed under a Cooperative Research and Development Agreement (CRADA) with the Air Force Research Laboratory.

  19. The Aerodynamic Drag of Five Models of Side Floats N.A.C.A. Models 51-E, 51-F, 51-G, 51-H, 51-J

    NASA Technical Reports Server (NTRS)

    House, R O

    1938-01-01

    The drag of five models of side floats was measured in the N.A.C.A. 7- by 10-foot wind tunnel. The most promising method of reducing the drag of floats indicated by these tests is lowering the angle at which the floats are rigged. The addition of a step to a float does not always increase the drag in the flying range, floats with steps sometimes having lower drag than similar floats without steps. Making the bow chine no higher than necessary might result in a reduction in air drag because of the lower angle of pitch of the chines. Since side floats are used formally to obtain lateral stability when the seaplane is operating on the water at slow speeds or at rest, greater consideration can be given to factors affecting aerodynamic drag than is possible for other types of floats and hulls.

  20. Hydrodynamic and Aerodynamic Tests of Models of Floats for Single-float Seaplanes NACA Models 41-D, 41-E, 61-A, 73, and 73-A

    NASA Technical Reports Server (NTRS)

    Parkinson, J B; HOUSE R O

    1938-01-01

    Tests were made in the NACA tank and in the NACA 7 by 10 foot wind tunnel on two models of transverse step floats and three models of pointed step floats considered to be suitable for use with single float seaplanes. The object of the program was the reduction of water resistance and spray of single float seaplanes without reducing the angle of dead rise believed to be necessary for the satisfactory absorption of the shock loads. The results indicated that all the models have less resistance and spray than the model of the Mark V float and that the pointed step floats are somewhat superior to the transverse step floats in these respects. Models 41-D, 61-A, and 73 were tested by the general method over a wide range of loads and speeds. The results are presented in the form of curves and charts for use in design calculations.

  1. Biotransformation of arsenite and bacterial aox activity in drinking water produced from surface water of floating houses: Arsenic contamination in Cambodia.

    PubMed

    Chang, Jin-Soo

    2015-11-01

    The potential arsenite bioteansformation activity of arsenic was investigated by examining bacterial arsenic arsenite-oxidizing gene such as aoxS, aoxR, aoxA, aoxB, aoxC, and aoxD in high arsenic-contaminated drinking water produced from the surface water of floating houses. There is a biogeochemical cycle of activity involving arsenite oxidase aox system and the ars (arsenic resistance system) gene operon and aoxR leader gene activity in Alcaligenes faecalis SRR-11 and aoxS leader gene activity in Achromobacter xylosoxidans TSL-66. Batch experiments showed that SRR-11 and TSL-66 completely oxidized 1 mM of As (III) to As (V) within 35-40 h. The leaders of aoxS and aoxR are important for gene activity, and their effects in arsenic bioremediation and mobility in natural water has a significant ecological role because it allows arsenite oxidase in bacteria to control the biogeochemical cycle of arsenic-contaminated drinking water produced from surface water of floating houses. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Gastroretentive Ranitidine Hydrochloride Tablets with Combined Floating and Bioadhesive Properties: Factorial Design Analysis, In Vitro Evaluation and In Vivo Abdominal X-Ray Imaging.

    PubMed

    Abduljabbar, Hana N; Badr-Eldin, Shaimaa M; Aldawsari, Hibah M

    2015-01-01

    Ranitidine HCl is an H2-antagonist that suffers from low oral bioavailability of 50%. The site-specific absorption from the upper part of the small intestine and the colonic metabolism of the drug could partially contribute to its reduced bioavailability. To surmount these drawbacks, this work aimed at the formulation of Ranitidine HCl gastroretentive floating-biaodhesive tablets. A 3(2) factorial design was applied to assess the effects of matrix former (HPMC K100M): drug ratio, and the release retardant (Carbopol 971) amount on the characteristics of the tablets prepared using direct compression technique. The prepared tablets were thoroughly evaluated for physical properties, floating, swelling, bioadhesive and in vitro release behaviors. Statistical analysis of the results revealed significant effects for both formulation variables on the swelling index, maximum detachment force and cumulative percent drug released after 6 hours. In addition, the matrix- former: drug ratio showed a statistically significant effect on the floating lag time. Kinetic analysis of the release data indicated Higuchi diffusion kinetics and anomalous transport mechanism for all formulations. Scanning electron micrographs of the selected tablet formulation; F8, revealed intact surface without any perforations or channels in the dry state, while polymer expansion (relaxation) with some perforated areas were observed on the surface of the tablets after 12 hours dissolution in 0.1 N HCl. Furthermore, in vivo abdominal x-ray imaging showed good floating behavior of the selected formulation; F8, for up to 6 hours with appropriate bioadhesive property. In conclusion, the selected ranitidine HCl floating-bioadhesive tablets could be regarded as a promising gastroretentive drug delivery system that could deliver the drug at a controlled rate.

  3. Culm Age and Rhizome Affects Night-Time Water Recharge in the Bamboo Phyllostachys pubescens

    PubMed Central

    Zhao, Xiuhua; Zhao, Ping; Zhang, Zhenzhen; Zhu, Liwei; Hu, Yanting; Ouyang, Lei; Ni, Guangyan; Ye, Qing

    2017-01-01

    Bamboo species—the only herbaceous trees—have unique structural and physiological characteristics that differ from those of other tree taxa. However, the role of night-time water use in bamboo is poorly understood and has rarely been investigated. We studied the day- and night-time sap flow response to culm age and rhizome structure in three age levels (juvenile, mature, and senescent) of Phyllostachys pubescens growing in the Nankun Mountain Natural Reserve, South China. We found that sap flow density and whole-tree hydraulic conductance decreased with culm age. After cutting of rhizome, the day-time sap flow and night-time water recharge decreased obviously. In addition, night-time water recharge accounted for the largest proportion (up to 30%) of total daily transpiration in normal senescent bamboos. Therefore, our study indicates that the connected rhizome system and night-time water recharge played a significant role in water compensation during the day and at night in bamboos. Night-time water recharge is especially critical to senescent bamboos, given their weaker transpiration due to the lower whole-tree hydraulic conductance, and consequently, they are more dependent on night-time water recharge for fulfilling their whole-day water consumption needs. PMID:29176989

  4. Culm Age and Rhizome Affects Night-Time Water Recharge in the Bamboo Phyllostachys pubescens.

    PubMed

    Zhao, Xiuhua; Zhao, Ping; Zhang, Zhenzhen; Zhu, Liwei; Hu, Yanting; Ouyang, Lei; Ni, Guangyan; Ye, Qing

    2017-01-01

    Bamboo species-the only herbaceous trees-have unique structural and physiological characteristics that differ from those of other tree taxa. However, the role of night-time water use in bamboo is poorly understood and has rarely been investigated. We studied the day- and night-time sap flow response to culm age and rhizome structure in three age levels (juvenile, mature, and senescent) of Phyllostachys pubescens growing in the Nankun Mountain Natural Reserve, South China. We found that sap flow density and whole-tree hydraulic conductance decreased with culm age. After cutting of rhizome, the day-time sap flow and night-time water recharge decreased obviously. In addition, night-time water recharge accounted for the largest proportion (up to 30%) of total daily transpiration in normal senescent bamboos. Therefore, our study indicates that the connected rhizome system and night-time water recharge played a significant role in water compensation during the day and at night in bamboos. Night-time water recharge is especially critical to senescent bamboos, given their weaker transpiration due to the lower whole-tree hydraulic conductance, and consequently, they are more dependent on night-time water recharge for fulfilling their whole-day water consumption needs.

  5. On The Dynamics and Design of a Two-body Wave Energy Converter

    NASA Astrophysics Data System (ADS)

    Liang, Changwei; Zuo, Lei

    2016-09-01

    A two-body wave energy converter oscillating in heave is studied in this paper. The energy is extracted through the relative motion between the floating and submerged bodies. A linearized model in the frequency domain is adopted to study the dynamics of such a two-body system with consideration of both the viscous damping and the hydrodynamic damping. The closed form solution of the maximum absorption power and corresponding power take-off parameters are obtained. The suboptimal and optimal designs for a two-body system are proposed based on the closed form solution. The physical insight of the optimal design is to have one of the damped natural frequencies of the two body system the same as, or as close as possible to, the excitation frequency. A case study is conducted to investigate the influence of the submerged body on the absorption power of a two-body system subjected to suboptimal and optimal design under regular and irregular wave excitations. It is found that the absorption power of the two-body system can be significantly higher than that of the single body system with the same floating buoy in both regular and irregular waves. In regular waves, it is found that the mass of the submerged body should be designed with an optimal value in order to achieve the maximum absorption power for the given floating buoy. The viscous damping on the submerged body should be as small as possible for a given mass in both regular and irregular waves.

  6. Program Converts VAX Floating-Point Data To UNIX

    NASA Technical Reports Server (NTRS)

    Alves, Marcos; Chapman, Bruce; Chu, Eugene

    1996-01-01

    VAX Floating Point to Host Floating Point Conversion (VAXFC) software converts non-ASCII files to unformatted floating-point representation of UNIX machine. This is done by reading bytes bit by bit, converting them to floating-point numbers, then writing results to another file. Useful when data files created by VAX computer must be used on other machines. Written in C language.

  7. Evaluation of a cost effective technique for treating aquaculture water discharge using Lolium perenne Lam as a biofilter.

    PubMed

    Nduwimana, André; Yang, Xiang-Long; Wang, Li-Ren

    2007-01-01

    Wastewater stabilization ponds generate low cost by-products that are useful for agriculture. The utilization of these by-products for soil amendment and as a source of nutrients for plants requires a high level of sanitation and stabilization of the organic matter, to maintain acceptable levels of soil, water and air quality. In this study, two aquaculture wastewater treatment systems; recirculating system and a floating plant bed system were designed to improve the quality of irrigation water in local communities with low income. In both systems the grass species Lolium perenne Lam was used as a plant biofilter while vegetable specie Amaranthus viridis was used to evaluate the performance of the system and the suitability of the phyto-treated water for irrigation. It was found that the harmful material removal rate for recirculating system was 88.9% for TAN (total ammonia nitrogen), 90% for NO2(-)-N, 64.8% for NO3(-)-N while for floating plant bed system 82.7% for TAN, 82% for NO2(-)-N and 60.5% for NO3(-)-N. Comparative analysis of the efficiency of waste element removal between the two systems revealed that both systems performed well, however, plant growth was not robust for floating plant bed system while recirculating system is energy consuming. Although both systems did not attain sufficient levels of TN (total nitrogen) and TP (total phosphorus) load reduction, the treatment with L. perenne remarkably improved the irrigation water quality. A. viridis plants irrigated with the phyto-treated discharge water had lesser concentrations of heavy metals in their tissues compared to those irrigated with untreated discharge. The control plants irrigated with untreated discharge were also found to be highly lignified with few stems and small leaves.

  8. Disturbance Reduction Control Design for the ST7 Flight Validation Experiment

    NASA Technical Reports Server (NTRS)

    Maghami, P. G.; Hsu, O. C.; Markley, F. L.; Houghton, M. B.

    2003-01-01

    The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass, and a set of micro-Newton colloidal thrusters. The ST7 Disturbance Reduction System is designed to maintain the spacecraft's position with respect to a free-floating test mass to less than 10 nm/Hz, over the frequency range of 1 to 30 mHz. This paper presents the design and analysis of the coupled, drag-free and attitude control systems that close the loop between the gravitational reference sensor and the micro-Newton thrusters, while incorporating star tracker data at low frequencies. A full 18 degree-of-freedom model, which incorporates rigid-body models of the spacecraft and two test masses, is used to evaluate the effects of actuation and measurement noise and disturbances on the performance of the drag-free system.

  9. Dynamic coupling of underactuated manipulators

    NASA Astrophysics Data System (ADS)

    Bergerman, Marcel; Lee, Christopher; Xu, Yangsheng

    1994-08-01

    In recent years, researchers have been turning their attention to so called underactuated systems, where the term underactuated refers to the fact that the system has more joints than control actuators. Some examples of underactuated systems are robot manipulators with failed actuators; free-floating space robots, where the base can be considered as a virtual passive linkage in inertia space; legged robots with passive joints; hyper-redundant (snake-like) robots with passive joints, etc. From the examples above, it is possible to justify the importance of the study of underactuated systems. For example, if some actuators of a conventional manipulator fail, the loss of one or more degrees of freedom may compromise an entire operation. In free-floating space systems, the base (satellite) can be considered as a 6-DOF device without positioning actuators. Finally, manipulators with passive joints and hyper-redundant robots with few actuators are important from the viewpoint of energy saving, lightweight design and compactness.

  10. Portable real-time color night vision

    NASA Astrophysics Data System (ADS)

    Toet, Alexander; Hogervorst, Maarten A.

    2008-03-01

    We developed a simple and fast lookup-table based method to derive and apply natural daylight colors to multi-band night-time images. The method deploys an optimal color transformation derived from a set of samples taken from a daytime color reference image. The colors in the resulting colorized multiband night-time images closely resemble the colors in the daytime color reference image. Also, object colors remain invariant under panning operations and are independent of the scene content. Here we describe the implementation of this method in two prototype portable dual band realtime night vision systems. One system provides co-aligned visual and near-infrared bands of two image intensifiers, the other provides co-aligned images from a digital image intensifier and an uncooled longwave infrared microbolometer. The co-aligned images from both systems are further processed by a notebook computer. The color mapping is implemented as a realtime lookup table transform. The resulting colorised video streams can be displayed in realtime on head mounted displays and stored on the hard disk of the notebook computer. Preliminary field trials demonstrate the potential of these systems for applications like surveillance, navigation and target detection.

  11. Night Shift Work Increases the Risks of Multiple Primary Cancers in Women: A Systematic Review and Meta-analysis of 61 Articles.

    PubMed

    Yuan, Xia; Zhu, Chenjing; Wang, Manni; Mo, Fei; Du, Wei; Ma, Xuelei

    2018-01-01

    A growing number of studies have examined associations between night shift work and the risks of common cancers among women, with varying conclusions. We did a meta-analysis to identify whether long-term night shift work increased the risks of common cancers in women. We enrolled 61 articles involving 114,628 cases and 3,909,152 participants from Europe, North America, Asia, and Australia. Risk estimates were performed with a random-effect model or a fixed-effect model. Subgroup analyses and meta-regression analyses about breast cancer were conducted to explore possible sources of heterogeneity. In addition, we carried out a dose-response analysis to quantitatively estimate the accumulative effect of night shift work on the risk of breast cancer. A positive relationship was revealed between long-term night shift work and the risks of breast [OR = 1.316; 95% confidence interval (CI), 1.196-1.448], digestive system (OR = 1.177; 95% CI, 1.065-1.301), and skin cancer (OR = 1.408; 95% CI, 1.024-1.934). For every 5 years of night shift work, the risk of breast cancer in women was increased by 3.3% (OR = 1.033; 95% CI, 1.012-1.056). Concerning the group of nurses, long-term night shift work presented potential carcinogenic effect in breast cancer (OR = 1.577; 95% CI, 1.235-2.014), digestive system cancer (OR = 1.350; 95% CI, 1.030-1.770), and lung cancer (OR = 1.280; 95% CI, 1.070-1.531). This systematic review confirmed the positive association between night shift work and the risks of several common cancers in women. We identified that cancer risk of women increased with accumulating years of night shift work, which might help establish and implement effective measures to protect female night shifters. Cancer Epidemiol Biomarkers Prev; 27(1); 25-40. ©2018 AACR . ©2018 American Association for Cancer Research.

  12. Nonlinear dynamical systems effects of homeopathic remedies on multiscale entropy and correlation dimension of slow wave sleep EEG in young adults with histories of coffee-induced insomnia.

    PubMed

    Bell, Iris R; Howerter, Amy; Jackson, Nicholas; Aickin, Mikel; Bootzin, Richard R; Brooks, Audrey J

    2012-07-01

    Investigators of homeopathy have proposed that nonlinear dynamical systems (NDS) and complex systems science offer conceptual and analytic tools for evaluating homeopathic remedy effects. Previous animal studies demonstrate that homeopathic medicines alter delta electroencephalographic (EEG) slow wave sleep. The present study extended findings of remedy-related sleep stage alterations in human subjects by testing the feasibility of using two different NDS analytic approaches to assess remedy effects on human slow wave sleep EEG. Subjects (N=54) were young adult male and female college students with a history of coffee-related insomnia who participated in a larger 4-week study of the polysomnographic effects of homeopathic medicines on home-based all-night sleep recordings. Subjects took one bedtime dose of a homeopathic remedy (Coffea cruda or Nux vomica 30c). We computed multiscale entropy (MSE) and the correlation dimension (Mekler-D2) for stages 3 and 4 slow wave sleep EEG sampled in artifact-free 2-min segments during the first two rapid-eye-movement (REM) cycles for remedy and post-remedy nights, controlling for placebo and post-placebo night effects. MSE results indicate significant, remedy-specific directional effects, especially later in the night (REM cycle 2) (CC: remedy night increases and post-remedy night decreases in MSE at multiple sites for both stages 3 and 4 in both REM cycles; NV: remedy night decreases and post-remedy night increases, mainly in stage 3 REM cycle 2 MSE). D2 analyses yielded more sporadic and inconsistent findings. Homeopathic medicines Coffea cruda and Nux vomica in 30c potencies alter short-term nonlinear dynamic parameters of slow wave sleep EEG in healthy young adults. MSE may provide a more sensitive NDS analytic method than D2 for evaluating homeopathic remedy effects on human sleep EEG patterns. Copyright © 2012 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  13. Nonlinear Dynamical Systems Effects of Homeopathic Remedies on Multiscale Entropy and Correlation Dimension of Slow Wave Sleep EEG in Young Adults with Histories of Coffee-Induced Insomnia

    PubMed Central

    Bell, Iris R.; Howerter, Amy; Jackson, Nicholas; Aickin, Mikel; Bootzin, Richard R.; Brooks, Audrey J.

    2012-01-01

    Background Investigators of homeopathy have proposed that nonlinear dynamical systems (NDS) and complex systems science offer conceptual and analytic tools for evaluating homeopathic remedy effects. Previous animal studies demonstrate that homeopathic medicines alter delta electroencephalographic (EEG) slow wave sleep. The present study extended findings of remedy-related sleep stage alterations in human subjects by testing the feasibility of using two different NDS analytic approaches to assess remedy effects on human slow wave sleep EEG. Methods Subjects (N=54) were young adult male and female college students with a history of coffee-related insomnia who participated in a larger 4-week study of the polysomnographic effects of homeopathic medicines on home-based all-night sleep recordings. Subjects took one bedtime dose of a homeopathic remedy (Coffea cruda or Nux vomica 30c). We computed multiscale entropy (MSE) and the correlation dimension (Mekler-D2) for stage 3 and 4 slow wave sleep EEG sampled in artifact-free 2-minute segments during the first two rapid-eye-movement (REM) cycles for remedy and post-remedy nights, controlling for placebo and post-placebo night effects. Results MSE results indicate significant, remedy-specific directional effects, especially later in the night (REM cycle 2) (CC: remedy night increases and post-remedy night decreases in MSE at multiple sites for both stages 3 and 4 in both REM cycles; NV: remedy night decreases and post-remedy night increases, mainly in stage 3 REM cycle 2 MSE). D2 analyses yielded more sporadic and inconsistent findings. Conclusions Homeopathic medicines Coffea cruda and Nux vomica in 30c potencies alter short-term nonlinear dynamic parameters of slow wave sleep EEG in healthy young adults. MSE may provide a more sensitive NDS analytic method than D2 for evaluating homeopathic remedy effects on human sleep EEG patterns. PMID:22818237

  14. The use of ZFP lossy floating point data compression in tornado-resolving thunderstorm simulations

    NASA Astrophysics Data System (ADS)

    Orf, L.

    2017-12-01

    In the field of atmospheric science, numerical models are used to produce forecasts of weather and climate and serve as virtual laboratories for scientists studying atmospheric phenomena. In both operational and research arenas, atmospheric simulations exploiting modern supercomputing hardware can produce a tremendous amount of data. During model execution, the transfer of floating point data from memory to the file system is often a significant bottleneck where I/O can dominate wallclock time. One way to reduce the I/O footprint is to compress the floating point data, which reduces amount of data saved to the file system. In this presentation we introduce LOFS, a file system developed specifically for use in three-dimensional numerical weather models that are run on massively parallel supercomputers. LOFS utilizes the core (in-memory buffered) HDF5 driver and includes compression options including ZFP, a lossy floating point data compression algorithm. ZFP offers several mechanisms for specifying the amount of lossy compression to be applied to floating point data, including the ability to specify the maximum absolute error allowed in each compressed 3D array. We explore different maximum error tolerances in a tornado-resolving supercell thunderstorm simulation for model variables including cloud and precipitation, temperature, wind velocity and vorticity magnitude. We find that average compression ratios exceeding 20:1 in scientifically interesting regions of the simulation domain produce visually identical results to uncompressed data in visualizations and plots. Since LOFS splits the model domain across many files, compression ratios for a given error tolerance can be compared across different locations within the model domain. We find that regions of high spatial variability (which tend to be where scientifically interesting things are occurring) show the lowest compression ratios, whereas regions of the domain with little spatial variability compress extremely well. We observe that the overhead for compressing data with ZFP is low, and that compressing data in memory reduces the amount of memory overhead needed to store the virtual files before they are flushed to disk.

  15. The Circadian System Contributes to Apnea Lengthening across the Night in Obstructive Sleep Apnea

    PubMed Central

    Butler, Matthew P.; Smales, Carolina; Wu, Huijuan; Hussain, Mohammad V.; Mohamed, Yusef A.; Morimoto, Miki; Shea, Steven A.

    2015-01-01

    Study Objective: To test the hypothesis that respiratory event duration exhibits an endogenous circadian rhythm. Design: Within-subject and between-subjects. Settings: Inpatient intensive physiologic monitoring unit at the Brigham and Women's Hospital. Participants: Seven subjects with moderate/severe sleep apnea and four controls, age 48 (SD = 12) years, 7 males. Interventions: Subjects completed a 5-day inpatient protocol in dim light. Polysomnography was recorded during an initial control 8-h night scheduled at the usual sleep time, then through 10 recurrent cycles of 2 h 40 min sleep and 2 h 40 min wake evenly distributed across all circadian phases, and finally during another 8-h control sleep period. Measurements and Results: Event durations, desaturations, and apnea-hypopnea index for each sleep opportunity were assessed according to circadian phase (derived from salivary melatonin), time into sleep, and sleep stage. Average respiratory event durations in NREM sleep significantly lengthened across both control nights (21.9 to 28.2 sec and 23.7 to 30.2 sec, respectively). During the circadian protocol, event duration in NREM increased across the circadian phases that corresponded to the usual sleep period, accounting for > 50% of the increase across normal 8-h control nights. AHI and desaturations were also rhythmic: AHI was highest in the biological day while desaturations were greatest in the biological night. Conclusions: The endogenous circadian system plays an important role in the prolongation of respiratory events across the night, and might provide a novel therapeutic target for modulating sleep apnea. Citation: Butler MP, Smales C, Wu H, Hussain MV, Mohamed YA, Morimoto M, Shea SA. The circadian system contributes to apnea lengthening across the night in obstructive sleep apnea. SLEEP 2015;38(11):1793–1801. PMID:26039970

  16. Spatial and temporal distribution of bull trout (Salvelinus confluentus)-size fish near the floating surface collector in the North Fork Reservoir, Oregon, 2016

    USGS Publications Warehouse

    Adams, Noah S.; Smith, Collin D.

    2017-06-26

    Acoustic cameras were used to assess the behavior and abundance of bull trout (Salvelinus confluentus)-size fish at the entrance to the North Fork Reservoir juvenile fish floating surface collector (FSC). The purpose of the FSC is to collect downriver migrating juvenile salmonids at the North Fork Dam, and safely route them around the hydroelectric projects. The objective of the acoustic camera component of this study was to assess the behaviors of bull trout-size fish observed near the FSC, and to determine if the presence of bull trout-size fish influenced the collection or abundance of juvenile salmonids. Acoustic cameras were deployed near the surface and floor of the entrance to the FSC. The acoustic camera technology was an informative tool for assessing abundance and spatial and temporal behaviors of bull trout-size fish near the entrance of the FSC. Bull trout-size fish were regularly observed near the entrance, with greater abundances on the deep camera than on the shallow camera. Additionally, greater abundances were observed during the hours of sunlight than were observed during the night. Behavioral differences also were observed at the two depths, with surface fish traveling faster and straighter with more directed movement, and fish observed on the deep camera generally showing more milling behavior. Modeling potential predator-prey interactions and influences using collected passive integrated transponder (PIT) -tagged juvenile salmonids proved largely unpredictable, although these fish provided relevant timing and collection information. Overall, the results indicate that bull trout-size fish are present near the entrance of the FSC, concomitant with juvenile salmonids, and their abundances and behaviors indicate that they may be drawn to the entrance of the FSC because of the abundance of prey-sized fish.

  17. 78 FR 54791 - Proposed Additional Airworthiness Design Standards: Advanced Avionics Under the Special Class...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-06

    ... and AC 21.17-3 limits JAR-VLA and CS-VLA aircraft approved under Sec. 21.17(b), to Day-VFR operations... include Night-VFR as shown in NPRM 75 FR 32576. In conjunction with the expansion to Night-VFR operations... requirements as Special Conditions as they did for the Night-VFR expansion. The FAA's system does not allow...

  18. Hydroelectric power from ocean waves

    NASA Astrophysics Data System (ADS)

    Raghavendran, K.

    1981-02-01

    This paper describes a system which converts the variable energy of ocean waves into a steady supply of energy in a conventional form. The system consists of a set of floats and Persian wheels located off-shore and a storage reservoir on the shore. The floats oscillate vertically as the waves pass below them and turn their respective Persian wheels which lift sea water to a height and deliver to the reservoir through an interconnecting pipeline. The head of water in the reservoir operates a hydraulic turbine which in turn works a generator to supply electricity. Due to the recurrent wave action, water is maintained at the optimum level in the reservoir to ensure continuous power supply.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayman, E. N.; Sclavounos, P. D.; Butterfield, S.

    This article presents a collaborative research program that the Massachusetts Institute of Technology (MIT) and the National Renewable Energy Laboratory (NREL) have undertaken to develop innovative and cost-effective floating and mooring systems for offshore wind turbines in water depths of 10-200 m. Methods for the coupled structural, hydrodynamic, and aerodynamic analysis of floating wind turbine systems are presented in the frequency domain. This analysis was conducted by coupling the aerodynamics and structural dynamics code FAST [4] developed at NREL with the wave load and response simulation code WAMIT (Wave Analysis at MIT) [15] developed at MIT. Analysis tools were developedmore » to consider coupled interactions between the wind turbine and the floating system. These include the gyroscopic loads of the wind turbine rotor on the tower and floater, the aerodynamic damping introduced by the wind turbine rotor, the hydrodynamic damping introduced by wave-body interactions, and the hydrodynamic forces caused by wave excitation. Analyses were conducted for two floater concepts coupled with the NREL 5-MW Offshore Baseline wind turbine in water depths of 10-200 m: the MIT/NREL Shallow Drafted Barge (SDB) and the MIT/NREL Tension Leg Platform (TLP). These concepts were chosen to represent two different methods of achieving stability to identify differences in performance and cost of the different stability methods. The static and dynamic analyses of these structures evaluate the systems' responses to wave excitation at a range of frequencies, the systems' natural frequencies, and the standard deviations of the systems' motions in each degree of freedom in various wind and wave environments. This article in various wind and wave environments. This article explores the effects of coupling the wind turbine with the floating platform, the effects of water depth, and the effects of wind speed on the systems' performance. An economic feasibility analysis of the two concepts was also performed. Key cost components included the material and construction costs of the buoy; material and installation costs of the tethers, mooring lines, and anchor technologies; costs of transporting and installing the system at the chosen site; and the cost of mounting the wind turbine to the platform. The two systems were evaluated based on their static and dynamic performance and the total system installed cost. Both systems demonstrated acceptable motions, and have estimated costs of $1.4-$1.8 million, not including the cost of the wind turbine, the power electronics, or the electrical transmission.« less

  20. A Roadmap to Continuous Integration for ATLAS Software Development

    NASA Astrophysics Data System (ADS)

    Elmsheuser, J.; Krasznahorkay, A.; Obreshkov, E.; Undrus, A.; ATLAS Collaboration

    2017-10-01

    The ATLAS software infrastructure facilitates efforts of more than 1000 developers working on the code base of 2200 packages with 4 million lines of C++ and 1.4 million lines of python code. The ATLAS offline code management system is the powerful, flexible framework for processing new package versions requests, probing code changes in the Nightly Build System, migration to new platforms and compilers, deployment of production releases for worldwide access and supporting physicists with tools and interfaces for efficient software use. It maintains multi-stream, parallel development environment with about 70 multi-platform branches of nightly releases and provides vast opportunities for testing new packages, for verifying patches to existing software and for migrating to new platforms and compilers. The system evolution is currently aimed on the adoption of modern continuous integration (CI) practices focused on building nightly releases early and often, with rigorous unit and integration testing. This paper describes the CI incorporation program for the ATLAS software infrastructure. It brings modern open source tools such as Jenkins and GitLab into the ATLAS Nightly System, rationalizes hardware resource allocation and administrative operations, provides improved feedback and means to fix broken builds promptly for developers. Once adopted, ATLAS CI practices will improve and accelerate innovation cycles and result in increased confidence in new software deployments. The paper reports the status of Jenkins integration with the ATLAS Nightly System as well as short and long term plans for the incorporation of CI practices.

  1. Characterization of cement float buoyancy in the stalked barnacle Dosima fascicularis (Crustacea, Cirripedia).

    PubMed

    Zheden, Vanessa; Kovalev, Alexander; Gorb, Stanislav N; Klepal, Waltraud

    2015-02-06

    Dosima fascicularis is the only barnacle which can drift autonomously at the water surface with a foam-like cement float. The cement secreted by the animal contains numerous gas-filled cells of different size. When several individuals share one float, their size and not their number is crucial for the production of both volume and mass of the float. The gas content within the cells of the foam gives positive static buoyancy to the whole float. The volume of the float, the gas volume and the positive static buoyancy are positively correlated. The density of the cement float without gas is greater than that of seawater. This study shows that the secreted cement consists of more than 90% water and the gas volume is on average 18.5%. Our experiments demonstrate that the intact foam-like cement float is sealed to the surrounding water.

  2. Characterization of cement float buoyancy in the stalked barnacle Dosima fascicularis (Crustacea, Cirripedia)

    PubMed Central

    Zheden, Vanessa; Kovalev, Alexander; Gorb, Stanislav N.; Klepal, Waltraud

    2015-01-01

    Dosima fascicularis is the only barnacle which can drift autonomously at the water surface with a foam-like cement float. The cement secreted by the animal contains numerous gas-filled cells of different size. When several individuals share one float, their size and not their number is crucial for the production of both volume and mass of the float. The gas content within the cells of the foam gives positive static buoyancy to the whole float. The volume of the float, the gas volume and the positive static buoyancy are positively correlated. The density of the cement float without gas is greater than that of seawater. This study shows that the secreted cement consists of more than 90% water and the gas volume is on average 18.5%. Our experiments demonstrate that the intact foam-like cement float is sealed to the surrounding water. PMID:25657839

  3. Collective motion of macroscopic spheres floating on capillary ripples: Dynamic heterogeneity and dynamic criticality

    NASA Astrophysics Data System (ADS)

    Sanlı, Ceyda; Saitoh, Kuniyasu; Luding, Stefan; van der Meer, Devaraj

    2014-09-01

    When a densely packed monolayer of macroscopic spheres floats on chaotic capillary Faraday waves, a coexistence of large scale convective motion and caging dynamics typical for glassy systems is observed. We subtract the convective mean flow using a coarse graining (homogenization) method and reveal subdiffusion for the caging time scales followed by a diffusive regime at later times. We apply the methods developed to study dynamic heterogeneity and show that the typical time and length scales of the fluctuations due to rearrangements of observed particle groups significantly increase when the system approaches its largest experimentally accessible packing concentration. To connect the system to the dynamic criticality literature, we fit power laws to our results. The resultant critical exponents are consistent with those found in densely packed suspensions of colloids.

  4. Collective motion of macroscopic spheres floating on capillary ripples: dynamic heterogeneity and dynamic criticality.

    PubMed

    Sanlı, Ceyda; Saitoh, Kuniyasu; Luding, Stefan; van der Meer, Devaraj

    2014-09-01

    When a densely packed monolayer of macroscopic spheres floats on chaotic capillary Faraday waves, a coexistence of large scale convective motion and caging dynamics typical for glassy systems is observed. We subtract the convective mean flow using a coarse graining (homogenization) method and reveal subdiffusion for the caging time scales followed by a diffusive regime at later times. We apply the methods developed to study dynamic heterogeneity and show that the typical time and length scales of the fluctuations due to rearrangements of observed particle groups significantly increase when the system approaches its largest experimentally accessible packing concentration. To connect the system to the dynamic criticality literature, we fit power laws to our results. The resultant critical exponents are consistent with those found in densely packed suspensions of colloids.

  5. a Floating Mobile Quay for Super Container Ships in a Hub Port

    NASA Astrophysics Data System (ADS)

    Chae, Jang-Won; Park, Woo-Sun

    A floating mobile quay (FMQ), which is an innovative berth system, has functions of not only both side loading/unloading but also direct transshipment to feeder ships in a hub port. Applying the FMQ to a hub port such as the west terminal of Busan New Port of Korea, it is shown from a physical modeling and field model test that the quay is dynamically stable and workable in the prevailing wave condition and also safe in a design storm condition, respectively. The terminal productivity is increased by 30% comparing with the present land based berth. The B/C ratio of the new berth system is evaluated as 1.13 considering super-large container ships. It appears that the FMQ is a technically and economically feasible system in the hub port.

  6. Autonomous Microstructure EM-APEX Floats

    DTIC Science & Technology

    2016-01-01

    Autonomous Microstructure_EM-APEX_Float 4/8/16 at 3:21 PM 1 Title: Autonomous Microstructure EM-APEX Floats Authors: Ren-Chieh Lien1,2...Street Seattle, WA 98105 rcl@uw.edu Abstract: Fast responding FP-07 thermistors have been incorporated on profiling EM-APEX floats to measure...storage board. The raw and processed temperature observations are stored on a microSD card. Results from eight microstructure EM-APEX floats

  7. Zero-power autonomous buoyancy system controlled by microbial gas production

    NASA Astrophysics Data System (ADS)

    Wu, Peter K.; Fitzgerald, Lisa A.; Biffinger, Justin C.; Spargo, Barry J.; Houston, Brian H.; Bucaro, Joseph A.; Ringeisen, Bradley R.

    2011-05-01

    A zero-power ballast control system that could be used to float and submerge a device solely using a gas source was built and tested. This system could be used to convey sensors, data loggers, and communication devices necessary for water quality monitoring and other applications by periodically maneuvering up and down a water column. Operational parameters for the system such as duration of the submerged and buoyant states can be varied according to its design. The gas source can be of any origin, e.g., compressed air, underwater gas vent, gas produced by microbes, etc. The zero-power ballast system was initially tested using a gas pump and further tested using gas produced by Clostridium acetobutylicum. Using microbial gas production as the only source of gas and no electrical power during operation, the system successfully floated and submerged periodically with a period of 30 min for at least 24 h. Together with microbial fuel cells, this system opens up possibilities for underwater monitoring systems that could function indefinitely.

  8. Comparison of Bispectral Index™ values during the flotation restricted environmental stimulation technique and results for stage I sleep: a prospective pilot investigation.

    PubMed

    Dunham, C Michael; McClain, Jesse V; Burger, Amanda

    2017-11-29

    To determine whether Bispectral Index™ values obtained during flotation-restricted environment stimulation technique have a similar profile in a single observation compared to literature-derived results found during sleep and other relaxation-induction interventions. Bispectral Index™ values were as follows: awake-state, 96.6; float session-1, 84.3; float session-2, 82.3; relaxation-induction, 82.8; stage I sleep, 86.0; stage II sleep, 66.2; and stages III-IV sleep, 45.1. Awake-state values differed from float session-1 (%difference 12.7%; Cohen's d = 3.6) and float session-2 (%difference 14.8%; Cohen's d = 4.6). Relaxation-induction values were similar to float session-1 (%difference 1.8%; Cohen's d = 0.3) and float session-2 (%difference 0.5%; Cohen's d = 0.1). Stage I sleep values were similar to float session-1 (%difference 1.9%; Cohen's d = 0.4) and float session-2 (%difference 4.3%; Cohen's d = 1.0). Stage II sleep values differed from float session-1 (%difference 21.5%; Cohen's d = 4.3) and float session-2 (%difference 19.6%; Cohen's d = 4.0). Stages III-IV sleep values differed from float session-1 (%difference 46.5%; Cohen's d = 5.6) and float session-2 (%difference 45.2%; Cohen's d = 5.4). Bispectral Index™ values during flotation were comparable to those found in stage I sleep and nadir values described with other relaxation-induction techniques.

  9. Floating electrode dielectrophoresis.

    PubMed

    Golan, Saar; Elata, David; Orenstein, Meir; Dinnar, Uri

    2006-12-01

    In practice, dielectrophoresis (DEP) devices are based on micropatterned electrodes. When subjected to applied voltages, the electrodes generate nonuniform electric fields that are necessary for the DEP manipulation of particles. In this study, electrically floating electrodes are used in DEP devices. It is demonstrated that effective DEP forces can be achieved by using floating electrodes. Additionally, DEP forces generated by floating electrodes are different from DEP forces generated by excited electrodes. The floating electrodes' capabilities are explained theoretically by calculating the electric field gradients and demonstrated experimentally by using test-devices. The test-devices show that floating electrodes can be used to collect erythrocytes (red blood cells). DEP devices which contain many floating electrodes ought to have fewer connections to external signal sources. Therefore, the use of floating electrodes may considerably facilitate the fabrication and operation of DEP devices. It can also reduce device dimensions. However, the key point is that DEP devices can integrate excited electrodes fabricated by microtechnology processes and floating electrodes fabricated by nanotechnology processes. Such integration is expected to promote the use of DEP devices in the manipulation of nanoparticles.

  10. Night driving restrictions for youthful drivers: a literature review and commentary.

    PubMed

    Williams, A F; Preusser, D F

    1997-01-01

    The research literature on night driving curfews is reviewed. Driving at night involves high risk, particularly for young beginners. Although only about 15 percent of the total miles of 16-17-year-old drivers occur between 9 p.m. and 6 a.m., about 40 percent of their fatal crashes take place during these hours. Curfews that limit recreational driving at night without an adult have been found to substantially reduce nighttime crashes. Parents of teenagers strongly endorse curfews and favor earlier starting times than prevail in most jurisdictions with curfews. A night driving curfew is an essential component of graduated licensing, a system that phases in young beginners to full-privilege licensure, limiting initial driving to lower-risk situations.

  11. Floating Probe Assembly for Measuring Temperature of Water

    NASA Technical Reports Server (NTRS)

    Stewart, Randy; Ruffin, Clyde

    2002-01-01

    A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (=71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in.(=1.9 cm) thick and 2.5 in. (=6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger.

  12. Floating Probe Assembly for Measuring Temperature of Water

    NASA Technical Reports Server (NTRS)

    Selinsky, T.; Stewart, Randy; Ruffin, Clyde

    2002-01-01

    A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (approx. = 71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in. (approx. = 1.9 cm) thick and 2.5 in. (approx. = 6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger. This work was done by Randy

  13. Characterization of Anopheles darlingi (Diptera: Culicidae) larval habitats in Belize, Central America

    NASA Technical Reports Server (NTRS)

    Manguin, S.; Roberts, D. R.; Andre, R. G.; Rejmankova, E.; Hakre, S.

    1996-01-01

    Surveys for larvae of Anopheles darlingi Root were conducted in April, May, and August 1994 in riverine habitats of central Belize (Cayo and Belize districts). An. darlingi was present during both the dry and wet seasons. Larvae were encountered most frequently in patches of floating debris along river margins. The floating mats were often formed by bamboo hanging over the banks and dense submersed bamboo roots. Larvae were found less frequently in lake margins, small lagoons, and ground pools with submersed roots and patches of floating leaves or vegetation. In addition to their association with floating debris, larvae of An. darlingi were associated positively with shade and submersed plants in riverine environments. Samples from river habitats showed the larvae of Anopheles albimanus Wiedemann to be strongly associated with sun-exposed sites containing green or blue-green algae. Unlike An. darlingi, An. albimanus was an ubiquitous mosquito, the immatures of which occurred in a wide variety of riverine and nonriverine aquatic habitats. Based on published reports and our experience, the association of An. darlingi with river systems was verified, and its distribution in Central America and Mexico was mapped.

  14. Analysis of post-earthquake reconstruction for Wenchuan earthquake based on night-time light data from DMSP/OLS

    NASA Astrophysics Data System (ADS)

    Cao, Yang; Zhang, Jing; Yang, Mingxiang; Lei, Xiaohui

    2017-07-01

    At present, most of Defense Meteorological Satellite Program's Operational Linescan System (DMSP/OLS) night-time light data are applied to large-scale regional development assessment, while there are little for the study of earthquake and other disasters. This study has extracted night-time light information before and after earthquake within Wenchuan county with adoption of DMSP/OLS night-time light data. The analysis results show that the night-time light index and average intensity of Wenchuan county were decreased by about 76% and 50% respectively from the year of 2007 to 2008. From the year of 2008 to 2011, the two indicators were increased by about 200% and 556% respectively. These research results show that the night-time light data can be used to extract the information of earthquake and evaluate the occurrence of earthquakes and other disasters.

  15. Validation of a FAST model of the Statoil-Hywind Demo floating wind turbine

    DOE PAGES

    Driscoll, Frederick; Jonkman, Jason; Robertson, Amy; ...

    2016-10-13

    To assess the accuracy of the National Renewable Energy Laboratory's (NREL's) FAST simulation tool for modeling the coupled response of floating offshore wind turbines under realistic open-ocean conditions, NREL developed a FAST model of the Statoil Hywind Demo floating offshore wind turbine, and validated simulation results against field measurements. Field data were provided by Statoil, which conducted a comprehensive test measurement campaign of its demonstration system, a 2.3-MW Siemens turbine mounted on a spar substructure deployed about 10 km off the island of Karmoy in Norway. A top-down approach was used to develop the FAST model, starting with modeling themore » blades and working down to the mooring system. Design data provided by Siemens and Statoil were used to specify the structural, aerodynamic, and dynamic properties. Measured wind speeds and wave spectra were used to develop the wind and wave conditions used in the model. The overall system performance and behavior were validated for eight sets of field measurements that span a wide range of operating conditions. The simulated controller response accurately reproduced the measured blade pitch and power. In conclusion, the structural and blade loads and spectra of platform motion agree well with the measured data.« less

  16. Morphology-Induced Collective Behaviors: Dynamic Pattern Formation in Water-Floating Elements

    PubMed Central

    Nakajima, Kohei; Ngouabeu, Aubery Marchel Tientcheu; Miyashita, Shuhei; Göldi, Maurice; Füchslin, Rudolf Marcel; Pfeifer, Rolf

    2012-01-01

    Complex systems involving many interacting elements often organize into patterns. Two types of pattern formation can be distinguished, static and dynamic. Static pattern formation means that the resulting structure constitutes a thermodynamic equilibrium whose pattern formation can be understood in terms of the minimization of free energy, while dynamic pattern formation indicates that the system is permanently dissipating energy and not in equilibrium. In this paper, we report experimental results showing that the morphology of elements plays a significant role in dynamic pattern formation. We prepared three different shapes of elements (circles, squares, and triangles) floating in a water-filled container, in which each of the shapes has two types: active elements that were capable of self-agitation with vibration motors, and passive elements that were mere floating tiles. The system was purely decentralized: that is, elements interacted locally, and subsequently elicited global patterns in a process called self-organized segregation. We showed that, according to the morphology of the selected elements, a different type of segregation occurs. Also, we quantitatively characterized both the local interaction regime and the resulting global behavior for each type of segregation by means of information theoretic quantities, and showed the difference for each case in detail, while offering speculation on the mechanism causing this phenomenon. PMID:22715370

  17. Bread board float zone experiment system for high purity silicon

    NASA Technical Reports Server (NTRS)

    Kern, E. L.; Gill, G. L., Jr.

    1982-01-01

    A breadboard float zone experimental system has been established at Westech Systems for use by NASA in the float zone experimental area. A used zoner of suitable size and flexibility was acquired and installed with the necessary utilities. Repairs, alignments and modifications were made to provide for dislocation free zoning of silicon. The zoner is capable of studying process parameters used in growing silicon in gravity and is flexible to allow trying of new features that will test concepts of zoning in microgravity. Characterizing the state of the art molten zones of a growing silicon crystal will establish the data base against which improvements of zoning in gravity or growing in microgravity can be compared. 25 mm diameter was chosen as the reference size, since growth in microgravity will be at that diameter or smaller for about the next 6 years. Dislocation free crystals were growtn in the 100 and 111 orientations, using a wide set of growth conditions. The zone shape at one set of conditions was measured, by simultaneously aluminum doping and freezing the zone, lengthwise slabbing and delineating by etching. The whole set of crystals, grown under various conditions, were slabbed, polished and striation etched, revealing the growth interface shape and the periodic and aperiodic natures of the striations.

  18. A novel control process of cyanobacterial bloom using cyanobacteriolytic bacteria immobilized in floating biodegradable plastic carriers.

    PubMed

    Nakamura, N; Nakano, K; Sugiura, N; Matsumura, M

    2003-12-01

    A process using a floating carrier for immobilization of cyanobacteriolytic bacteria, B.cereus N-14, was proposed to realize an effective in situ control of natural floating cyanobacterial blooms. The critical concentrations of the cyanobacteriolytic substance and B.cereus N-14 cells required to exhibit cyanobacteriolytic activity were investigated. The results indicated the necessity of cell growth to produce sufficiently high amounts of the cyanobacteriolytic substance to exhibit its activity and also for conditions enabling good contact between high concentrations of the cyanobacteriolytic substance and cyanobacteria. Floating biodegradable plastics made of starch were applied as a carrier material to maintain close contact between the immobilized cyanobacteriolytic bacteria and floating cyanobacteria. The floating starch-carriers could eliminate 99% of floating cyanobacteria in 4 d. Since B.cereus N-14 could produce the cyanobacteriolytic substance under the presence of starch and some amino acids, the cyanobacteriolytic activity could be attributed to carbon source fed from starch carrier and amino acids eluted from lysed cyanobacteria. Therefore, the effect of using a floating starch-carrier was confirmed from both view points as a carrier for immobilization and a nutrient source to stimulate cyanobacteriolytic activity. The new concept to apply a floating carrier immobilizing useful microorganisms for intensive treatment of a nuisance floating target was demonstrated.

  19. [Treatment effect of biological filtration and vegetable floating-bed combined system on greenhouse turtle breeding wastewater].

    PubMed

    Chen, Chong-Jun; Zhang, Rui; Xiang, Kun; Wu, Wei-Xiang

    2014-08-01

    Unorganized discharge of greenhouse turtle breeding wastewater has brought several negative influences on the ecological environment in the rural area of Yangtze River Delta. Biological filtration and vegetable floating-bed combined system is a potential ecological method for greenhouse turtle breeding wastewater treatment. In order to explore the feasibility of this system and evaluate the contribution of vegetable uptake of nitrogen (N) and phosphorus (P) in treating greenhouse turtle breeding wastewater, three types of vegetables, including Ipomoea aquatica, lettuce and celery were selected in this study. Results showed the combined system had a high capacity in simultaneous removal of organic matter, N and P. The removal efficiencies of COD, NH4(+)-N, TN and TP from the wastewater reached up to 93.2%-95.6%, 97.2%-99.6%, 73.9%-93.1% and 74.9%-90.0%, respectively. System with I. aquatica had the highest efficiencies in N and P removal, followed by lettuce and celery. However, plant uptake was not the primary pathway for TN arid TP removal in the combined system. The vegetable uptake of N and P accounted for only 9.1%-25.0% of TN and TP removal from the wastewater while the effect of microorganisms would be dominant for N and P removal. In addition, the highest amounts of N and P uptake in I. aquatica were closely related with the biomass of plant. Results from the study indicated that the biological filtration and vegetable floating-bed combined system was an effective approach to treating greenhouse turtle breeding wastewater in China.

  20. Development of a Novel Floating In-situ Gelling System for Stomach Specific Drug Delivery of the Narrow Absorption Window Drug Baclofen.

    PubMed

    R Jivani, Rishad; N Patel, Chhagan; M Patel, Dashrath; P Jivani, Nurudin

    2010-01-01

    The present study deals with development of a floating in-situ gel of the narrow absorption window drug baclofen. Sodium alginate-based in-situ gelling systems were prepared by dissolving various concentrations of sodium alginate in deionized water, to which varying concentrations of drug and calcium bicarbonate were added. Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) were used to check the presence of any interaction between the drug and the excipients. A 3(2) full factorial design was used for optimization. The concentrations of sodium alginate (X1) and calcium bicarbonate (X2) were selected as the independent variables. The amount of the drug released after 1 h (Q1) and 10 h (Q10) and the viscosity of the solution were selected as the dependent variables. The gels were studied for their viscosity, in-vitro buoyancy and drug release. Contour plots were drawn for each dependent variable and check-point batches were prepared in order to get desirable release profiles. The drug release profiles were fitted into different kinetic models. The floating lag time and floating time found to be 2 min and 12 h respectively. A decreasing trend in drug release was observed with increasing concentrations of CaCO3. The computed values of Q1 and Q10 for the check-point batch were 25% and 86% respectively, compared to the experimental values of 27.1% and 88.34%. The similarity factor (f 2) for the check-point batch being 80.25 showed that the two dissolution profiles were similar. The drug release from the in-situ gel follows the Higuchi model, which indicates a diffusion-controlled release. A stomach specific in-situ gel of baclofen could be prepared using floating mechanism to increase the residence time of the drug in stomach and thereby increase the absorption.

  1. Night ventilation control strategies in office buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhaojun; Yi, Lingli; Gao, Fusheng

    2009-10-15

    In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factorsmore » influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)« less

  2. Night Vision Laboratory Static Performance Model for Thermal Viewing Systems

    DTIC Science & Technology

    1975-04-01

    Research and Development Technical Report f ECOM-� • i’.__1’=• =•NIGHT VISION LABORATORY STATIC PERFORMANCE MODEL 1 S1=• : FOR THERMAL VIEWING...resolvable temperature Infrared imaging Minimum detectable temperature1.Detection and recognition performance Night visi,-)n Noise equivalent temperature...modulation transfer function (MTF). The noise charactcristics are specified by the noise equivalent temper- ature difference (NE AT), The next sections

  3. Phase-change wallboard and mechanical night ventilation in commercial buildings: Potential for HVAC system downsizing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stetiu, C.; Feustel, H.E.

    1998-07-01

    As thermal storage media, phase-change materials (PCMs) such as paraffin, eutectic salts, etc. offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. By embedding PCMs in dypsum board, plaster, or other wall-covering materials, the building structure acquires latent storage properties. Structural elements containing PCMs can store large amounts of energy while maintaining the indoor temperature within a relatively narrow range. As heat storage takes place inside the building where the loads occur, rather than at a central exterior location, the internal loads are removed without the need for additional transport energy. Distributed latent storage canmore » thus be used to reduce the peak power demand of a building, downsize the cooling system, and/or switch to low-energy cooling sources. The authors used RADCOOL, a thermal building simulation program based on the finite difference approach, to numerically evaluate the thermal performance of PCM wallboard coupled with mechanical night ventilation in office buildings offers the opportunity for system downsizing in climates where the outside air temperature drops below 18 C at night. In climates where the outside air temperature remains above 19 C at night, the use of PCM wallboard should be coupled with discharge mechanisms other than mechanical night ventilation with outside air.« less

  4. Helicopter human factors

    NASA Technical Reports Server (NTRS)

    Hart, Sandra G.

    1988-01-01

    The state-of-the-art helicopter and its pilot are examined using the tools of human-factors analysis. The significant role of human error in helicopter accidents is discussed; the history of human-factors research on helicopters is briefly traced; the typical flight tasks are described; and the noise, vibration, and temperature conditions typical of modern military helicopters are characterized. Also considered are helicopter controls, cockpit instruments and displays, and the impact of cockpit design on pilot workload. Particular attention is given to possible advanced-technology improvements, such as control stabilization and augmentation, FBW and fly-by-light systems, multifunction displays, night-vision goggles, pilot night-vision systems, night-vision displays with superimposed symbols, target acquisition and designation systems, and aural displays. Diagrams, drawings, and photographs are provided.

  5. Comparison of glucose fluctuations between day- and night-time measured using a continuous glucose monitoring system in diabetic dogs.

    PubMed

    Mori, Akihiro; Kurishima, Miyuki; Oda, Hitomi; Saeki, Kaori; Arai, Toshiro; Sako, Toshinori

    2013-01-31

    Monitoring of blood glucose concentration is important to evaluate the diabetic status of dogs. Continuous glucose monitoring systems (CGMS) have been applied in veterinary medicine for glucose monitoring in diabetic dogs. The purpose of the study was to evaluate the daily glycemic profiles obtained with CGMS and compare glucose fluctuations between day- and night-time in diabetic dogs. Five diabetic dogs were used in this study and were treated with either NPH insulin or insulin detemir. For data analyses, day-time was defined as 9:00 am-9:00 pm and night-time as 9:00 pm-9:00 am. Using glucose profiles, we determined the mean glucose concentrations (1- and 12-hr intervals), and times spent in hyperglycemia >200 mg/dl or hypoglycemia <60 mg/dl. None of the parameters differed significantly between day-time and night-time in dogs treated with NPH insulin or insulin detemir. In conclusion, this study confirmed, using CGMS, that there are no differences in glucose fluctuations between day- and night-time, in diabetic dogs on a similar feeding regimen and insulin administration.

  6. Can mobile technology improve response times of junior doctors to urgent out-of-hours calls? A prospective observational study.

    PubMed

    Herrod, P J J; Barclay, C; Blakey, J D

    2014-04-01

    The Hospital at Night system has been widely adopted to manage Out-of-Hours workload. However, it has the potential to introduce delays and corruption of information. The introduction of newer technologies to replace landlines, pagers and paper may ameliorate these issues. To establish if the introduction of a Hospital at Night system supported by a wireless taskflow system affected the escalation of high Early Warning Scores (EWSs) to medical attention, and the time taken to medical review. Prospective 'pre and post' observational study in a teaching hospital in the UK. Review of observation charts and medical records, and data extraction from the electronic taskflow system. The implementation of a technology-supported Hospital at Night system was associated with a significant decrease in time to documentation of initial review in those who were reviewed. However, there was no change in the proportion of those with a high EWS that were reviewed, and throughout the study a majority of patients with high EWSs were not reviewed in accordance with guidelines. Introduction of a Hospital at Night system supported by mobile technology appeared to improve the transfer of information, but did not affect the nursing decision whether to escalate abnormal findings.

  7. Large-scale environmental degradation results in inequitable impacts to already impoverished communities: A case study from the floating villages of Cambodia.

    PubMed

    Althor, Glenn; Mahood, Simon; Witt, Bradd; Colvin, Rebecca M; Watson, James E M

    2018-02-19

    Cambodian subsistence communities within the Tonle Sap Great Lake area rely on resource extraction from the lake to meet livelihood needs. These fishing communities-many of which consist of dwellings floating on the lake-face potentially profound livelihood challenges because of climate change and changing hydrology due to dam construction for hydroelectricity within the Mekong Basin. We conducted interviews across five village communities, with local subsistence fisher people in the Tonle Sap in 2015, and used thematic analysis methods to reveal a fishery system that is undergoing rapid ecological decline, with local fishing communities increasingly experiencing reductions in available fish stocks. As a result, over 100 000 people living in these communities are experiencing a direct loss of well-being and livelihood. We discuss these losses and consider their implications for the future viability of Cambodian floating village communities.

  8. ISS Plasma Interaction: Measurements and Modeling

    NASA Technical Reports Server (NTRS)

    Barsamian, H.; Mikatarian, R.; Alred, J.; Minow, J.; Koontz, S.

    2004-01-01

    Ionospheric plasma interaction effects on the International Space Station are discussed in the following paper. The large structure and high voltage arrays of the ISS represent a complex system interacting with LEO plasma. Discharge current measurements made by the Plasma Contactor Units and potential measurements made by the Floating Potential Probe delineate charging and magnetic induction effects on the ISS. Based on theoretical and physical understanding of the interaction phenomena, a model of ISS plasma interaction has been developed. The model includes magnetic induction effects, interaction of the high voltage solar arrays with ionospheric plasma, and accounts for other conductive areas on the ISS. Based on these phenomena, the Plasma Interaction Model has been developed. Limited verification of the model has been performed by comparison of Floating Potential Probe measurement data to simulations. The ISS plasma interaction model will be further tested and verified as measurements from the Floating Potential Measurement Unit become available, and construction of the ISS continues.

  9. Assessment of Experimental Uncertainty for a Floating Wind Semisubmersible under Hydrodynamic Loading: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Amy N; Wendt, Fabian F; Jonkman, Jason

    The objective of this paper is to assess the sources of experimental uncertainty in an offshore wind validation campaign focused on better understanding the nonlinear hydrodynamic response behavior of a floating semisubmersible. The test specimen and conditions were simplified compared to other floating wind test campaigns to reduce potential sources of uncertainties and better focus on the hydrodynamic load attributes. Repeat tests were used to understand the repeatability of the test conditions and to assess the level of random uncertainty in the measurements. Attention was also given to understanding bias in all components of the test. The end goal ofmore » this work is to set uncertainty bounds on the response metrics of interest, which will be used in future work to evaluate the success of modeling tools in accurately calculating hydrodynamic loads and the associated motion responses of the system.« less

  10. Free float and stochastic volatility: the experience of a small open economy

    NASA Astrophysics Data System (ADS)

    Selçuk, Faruk

    2004-11-01

    Following a dramatic collapse of a fixed exchange rate based inflation stabilization program, Turkey moved into a free floating exchange rate system in February 2001. In this paper, an asymmetric stochastic volatility model of the foreign exchange rate in Turkey is estimated for the floating period. It is shown that there is a positive relation between the exchange return and its volatility. Particularly, an increase in the return at time t results in an increase in volatility at time t+1. However, the effect is asymmetric: a decrease in the exchange rate return at time t causes a relatively less decrease in volatility at time t+1. The results imply that a central bank with a volatility smoothing policy would be biased in viewing the shocks to the exchange rate in favor of appreciation. The bias would increase if the bank is also following an inflation targeting policy.

  11. DEVELOPMENT OF A SORBENT DISTRIBUTION AND RECOVERY SYSTEM

    EPA Science Inventory

    This report describes the design, fabrication, and test of a prototype system for the recovery of spilled oil from the surface of river, estuarine, and harbor waters. The system utilizes an open cell polyurethane foam in small cubes to absorb the floating oil. The system is highl...

  12. Erratum: "Low vibration laboratory with a single-stage vibration isolation for microscopy applications" [Rev. Sci. Instrum. 88, 023703 (2017)

    NASA Astrophysics Data System (ADS)

    Voigtländer, Bert; Coenen, Peter; Cherepanov, Vasily; Borgens, Peter; Duden, Thomas; Tautz, F. Stefan

    2018-01-01

    The construction and the vibrational performance of a low vibration laboratory for microscopy applications comprising a 100 ton floating foundation supported by passive pneumatic isolators (air springs), which rest themselves on a 200 ton solid base plate is discussed. The optimization of the air spring system lead to a vibration level on the floating floor below that induced by an acceleration of 10 ng for most frequencies. Additional acoustic and electromagnetic isolation is accomplished by a room-in-room concept.

  13. Geographic Resources Analysis Support System (GRASS) Version 4.0 User’s Reference Manual

    DTIC Science & Technology

    1992-06-01

    inpur-image need not be square; before processing, the X and Y dimensions of the input-image are padded with zeroes to the next highest power of two in...structures an input kowledge /control script with an appropriate combination of map layer category values (GRASS raster map layers that contain data on...F cos(x) cosine of x (x is in degrees) F exp(x) exponential function of x F exp(x,y) x to the power y F float(x) convert x to floating point F if

  14. STS-32 MS Dunbar wearing LES floats in life raft during water egress training

    NASA Image and Video Library

    1989-11-15

    STS-32 Mission Specialist (MS) Bonnie J. Dunbar, wearing a launch and entry suit (LES) and lauch and entry helmet (LEH), in a single-occupant (one man) lift raft enlists the aid of two SCUBA-equipped divers as she floats in 25 ft deep pool located in JSC's Weightless Environment Training Facility (WETF) Bldg 29. During the exercises the crew practiced the procedures to follow in the event of an emergency aboard the Space Shuttle and familiarized themselves with post-Challenger pole system of emergency egress.

  15. STS-32 MS Dunbar wearing LES floats in life raft during water egress training

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-32 Mission Specialist (MS) Bonnie J. Dunbar, wearing a launch and entry suit (LES) and lauch and entry helmet (LEH), in a single-occupant (one man) lift raft enlists the aid of two SCUBA-equipped divers as she floats in 25 ft deep pool located in JSC's Weightless Environment Training Facility (WETF) Bldg 29. During the exercises the crew practiced the procedures to follow in the event of an emergency aboard the Space Shuttle and familiarized themselves with post-Challenger pole system of emergency egress.

  16. 40 CFR 426.50 - Applicability; description of the float glass manufacturing subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... float glass manufacturing subcategory. 426.50 Section 426.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Float Glass Manufacturing Subcategory § 426.50 Applicability; description of the float glass...

  17. 40 CFR 426.50 - Applicability; description of the float glass manufacturing subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... float glass manufacturing subcategory. 426.50 Section 426.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Float Glass Manufacturing Subcategory § 426.50 Applicability; description of the float glass...

  18. Tethered float liquid level sensor

    DOEpatents

    Daily, III, William Dean

    2016-09-06

    An apparatus for sensing the level of a liquid includes a float, a tether attached to the float, a pulley attached to the tether, a rotation sensor connected to the pulley that senses vertical movement of said float and senses the level of the liquid.

  19. 40 CFR 264.1085 - Standards: Surface impoundments.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the surface impoundment by installing and operating either of the following: (1) A floating membrane... from a surface impoundment using a floating membrane cover shall meet the requirements specified in... floating membrane cover designed to meet the following specifications: (i) The floating membrane cover...

  20. Metabolism and Growth in Arabidopsis Depend on the Daytime Temperature but Are Temperature-Compensated against Cool Nights[W][OA

    PubMed Central

    Pyl, Eva-Theresa; Piques, Maria; Ivakov, Alexander; Schulze, Waltraud; Ishihara, Hirofumi; Stitt, Mark; Sulpice, Ronan

    2012-01-01

    Diurnal cycles provide a tractable system to study the response of metabolism and growth to fluctuating temperatures. We reasoned that the response to daytime and night temperature may vary; while daytime temperature affects photosynthesis, night temperature affects use of carbon that was accumulated in the light. Three Arabidopsis thaliana accessions were grown in thermocycles under carbon-limiting conditions with different daytime or night temperatures (12 to 24°C) and analyzed for biomass, photosynthesis, respiration, enzyme activities, protein levels, and metabolite levels. The data were used to model carbon allocation and growth rates in the light and dark. Low daytime temperature led to an inhibition of photosynthesis and an even larger inhibition of growth. The inhibition of photosynthesis was partly ameliorated by a general increase in protein content. Low night temperature had no effect on protein content, starch turnover, or growth. In a warm night, there is excess capacity for carbon use. We propose that use of this capacity is restricted by feedback inhibition, which is relaxed at lower night temperature, thus buffering growth against fluctuations in night temperature. As examples, the rate of starch degradation is completely temperature compensated against even sudden changes in temperature, and polysome loading increases when the night temperature is decreased. PMID:22739829

  1. Night work and prostate cancer in men: a Swedish prospective cohort study

    PubMed Central

    Åkerstedt, Torbjrn; Narusyte, Jurgita; Svedberg, Pia; Kecklund, Göran; Alexanderson, Kristina

    2017-01-01

    Objectives Prostate cancer is the most common cancer and the second leading cause of cancer-related deaths among men, but the contributing factors are unclear. One such may be night work because of the day/night alternation of work and the resulting disturbance of the circadian system. The purpose of the present study was to investigate the prospective relation between number of years with night work and prostate cancer in men. Design Cohort study comparing night and day working twins with respect to incident prostate cancer in 12 322 men. Setting Individuals in the Swedish Twin Registry. Participants 12 322 male twins. Outcome measures Prostate cancer diagnoses obtained from the Swedish Cancer Registry with a follow-up time of 12 years, with a total number of cases=454. Results Multiple Cox proportional hazard regression analysis, adjusted for a number of covariates, showed no association between ever night work and prostate cancer, nor for duration of night work and prostate cancer. Analysis of twin pairs discordant for prostate cancer (n=332) showed no significant association between night work and prostate cancer. Conclusions The results, together with previous studies, suggest that night work does not seem to constitute a risk factor for prostate cancer. PMID:28600375

  2. Preliminary results from DIMES: Dispersion in the ACC

    NASA Astrophysics Data System (ADS)

    Balwada, D.; Speer, K.; LaCasce, J. H.; Owens, B.

    2012-04-01

    The Diapycnal and Isopynal Mixing Experiment in the Southern Ocean (DIMES) is a CLIVAR process study designed to study mixing in the Antarctic Circumpolar Current. The experiment includes tracer release, float, and small-scale turbulence components. This presentation will report on some results of the float component, from floats deployed across the ACC in the Southeast Pacific Ocean. These are the first subsurface Lagrangian trajectories from the ACC. Floats were deployed to follow approximately a constant density surface for a period of 1-3 years. To help aid the experimental results virtual floats were advected using AVISO data and basic statistics were derived from both deployed and virtual float trajectories. Experimental design, initial results, comparison to virtual floats and single particle and relative dispersion calculations will be presented.

  3. Estimating adolescent sleep need using dose-response modeling.

    PubMed

    Short, Michelle A; Weber, Nathan; Reynolds, Chelsea; Coussens, Scott; Carskadon, Mary A

    2018-04-01

    This study will (1) estimate the nightly sleep need of human adolescents, (2) determine the time course and severity of sleep-related deficits when sleep is reduced below this optimal quantity, and (3) determine whether sleep restriction perturbs the circadian system as well as the sleep homeostat. Thirty-four adolescents aged 15 to 17 years spent 10 days and nine nights in the sleep laboratory. Between two baseline nights and two recovery nights with 10 hours' time in bed (TIB) per night, participants experienced either severe sleep restriction (5-hour TIB), moderate sleep restriction (7.5-hour TIB), or no sleep restriction (10-hour TIB) for five nights. A 10-minute psychomotor vigilance task (PVT; lapse = response after 500 ms) and the Karolinska Sleepiness Scale were administered every 3 hours during wake. Salivary dim-light melatonin onset was calculated at baseline and after four nights of each sleep dose to estimate circadian phase. Dose-dependent deficits to sleep duration, circadian phase timing, lapses of attention, and subjective sleepiness occurred. Less TIB resulted in less sleep, more lapses of attention, greater subjective sleepiness, and larger circadian phase delays. Sleep need estimated from 10-hour TIB sleep opportunities was approximately 9 hours, while modeling PVT lapse data suggested that 9.35 hours of sleep is needed to maintain optimal sustained attention performance. Sleep restriction perturbs homeostatic and circadian systems, leading to dose-dependent deficits to sustained attention and sleepiness. Adolescents require more sleep for optimal functioning than typically obtained.

  4. Floating Offshore WTG Integrated Load Analysis & Optimization Employing a Tuned Mass Damper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez Tsouroukdissian, Arturo; Lackner, Matt; Cross-Whiter, John

    2015-09-25

    Floating offshore wind turbines (FOWTs) present complex design challenges due to the coupled dynamics of the platform motion, mooring system, and turbine control systems, in response to wind and wave loading. This can lead to higher extreme and fatigue loads than a comparable fixed bottom or onshore system. Previous research[1] has shown the potential to reduced extreme and fatigue loads on FOWT using tuned mass dampers (TMD) for structural control. This project aims to reduce maximum loads using passive TMDs located at the tower top during extreme storm events, when grid supplied power for other controls systems may not bemore » available. The Alstom Haliade 6MW wind turbine is modelled on the Glosten Pelastar tension-leg platform (TLP). The primary objectives of this project are to provide a preliminary assessment of the load reduction potential of passive TMDs on real wind turbine and TLP designs.« less

  5. Hardware description ADSP-21020 40-bit floating point DSP as designed in a remotely controlled digital CW Doppler radar

    NASA Astrophysics Data System (ADS)

    Morrison, R. E.; Robinson, S. H.

    A continuous wave Doppler radar system has been designed which is portable, easily deployed, and remotely controlled. The heart of this system is a DSP/control board using Analog Devices ADSP-21020 40-bit floating point digital signal processor (DSP) microprocessor. Two 18-bit audio A/D converters provide digital input to the DSP/controller board for near real time target detection. Program memory for the DSP is dual ported with an Intel 87C51 microcontroller allowing DSP code to be up-loaded or down-loaded from a central controlling computer. The 87C51 provides overall system control for the remote radar and includes a time-of-day/day-of-year real time clock, system identification (ID) switches, and input/output (I/O) expansion by an Intel 82C55 I/O expander.

  6. The potential of oceanic transport and onshore leaching of additive-derived lead by marine macro-plastic debris.

    PubMed

    Nakashima, Etsuko; Isobe, Atsuhiko; Kako, Shin'ichiro; Itai, Takaaki; Takahashi, Shin; Guo, Xinyu

    2016-06-15

    The long-distance transport potential of toxic lead (Pb) by plastic marine debris was examined by pure water leaching experiments using plastic fishery floats containing high level of additive-Pb such as 5100±74.3mgkg(-1). The leaching of Pb ended after sequential 480-h leaching experiments, and the total leaching amount is equivalent to approximately 0.1% of total Pb in a float. But it recovered when the float was scratched using sandpaper. We propose that a "low-Pb layer," in which Pb concentration is negligibly small, be generated on the float surface by the initial leaching process. Thickness of the layer is estimated at 2.5±1.2μm, much shallower than flaws on floats scratched by sandpaper and floats littering beaches. The result suggests that the low-Pb layer is broken by physical abrasion when floats are washed ashore, and that Pb inside the floats can thereafter leach into beaches. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Advanced Active-Magnetic-Bearing Thrust-Measurement System

    NASA Technical Reports Server (NTRS)

    Imlach, Joseph; Kasarda, Mary; Blumber, Eric

    2008-01-01

    An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active-magnetic-bearing force-measurement systems is to calculate levitation forces on the basis of simple proportionalities between changes in those forces and changes in feedback-controlled currents applied to levitating electromagnetic coils. In the prior systems, the effects of gap lengths on fringing magnetic fields and the concomitant effects on magnetic forces were neglected. In the present system, the control subsystems of the active magnetic bearings are coupled with a computer-based automatic calibration system running special-purpose software wherein gap-length-dependent fringing factors are applied to current and magnetic-flux-based force equations and combined with a multipoint calibration method to obtain greater accuracy.

  8. Identification of mothball powder composition by float tests and melting point tests.

    PubMed

    Tang, Ka Yuen

    2018-07-01

    The aim of the study was to identify the composition, as either camphor, naphthalene, or paradichlorobenzene, of mothballs in the form of powder or tiny fragments by float tests and melting point tests. Naphthalene, paradichlorobenzene and camphor mothballs were blended into powder and tiny fragments (with sizes <1/10 of the size of an intact mothball). In the float tests, the mothball powder and tiny fragments were placed in water, saturated salt solution and 50% dextrose solution (D50), and the extent to which they floated or sank in the liquids was observed. In the melting point tests, the mothball powder and tiny fragments were placed in hot water with a temperature between 53 and 80 °C, and the extent to which they melted was observed. Both the float and melting point tests were then repeated using intact mothballs. Three emergency physicians blinded to the identities of samples and solutions visually evaluated each sample. In the float tests, paradichlorobenzene powder partially floated and partially sank in all three liquids, while naphthalene powder partially floated and partially sank in water. Naphthalene powder did not sink in D50 or saturated salt solution. Camphor powder floated in all three liquids. Float tests identified the compositions of intact mothball accurately. In the melting point tests, paradichlorobenzene powder melted completely in hot water within 1 min while naphthalene powder and camphor powder did not melt. The melted portions of paradichlorobenzene mothballs were sometimes too small to be observed in 1 min but the mothballs either partially or completely melted in 5 min. Both camphor and naphthalene intact mothballs did not melt in hot water. For mothball powder, the melting point tests were more accurate than the float tests in differentiating between paradichlorobenzene and non-paradichlorobenzene (naphthalene or camphor). For intact mothballs, float tests performed better than melting point tests. Float tests can identify camphor mothballs but melting point tests cannot. We suggest melting point tests for identifying mothball powder and tiny fragments while float tests are recommended for intact mothball and large fragments.

  9. Driver eye-scanning behavior at intersections at night.

    DOT National Transportation Integrated Search

    2009-10-01

    This research project analyzed drivers eye scanning behavior at night when approaching signalized : and unsignalized intersections using the data from a head-mounted eye-tracking system during open road : driving on a prescribed route. During the ...

  10. Night-to-Night Variability of Muscle Tone, Movements, and Vocalizations in Patients with REM Sleep Behavior Disorder

    PubMed Central

    Cygan, Fanny; Oudiette, Delphine; Leclair-Visonneau, Laurène; Leu-Semenescu, Smaranda; Arnulf, Isabelle

    2010-01-01

    Objectives: The video-polysomnographic criteria of REM sleep behavior disorder (RBD) have not been well described. We evaluated the between-night reproducibility of phasic and tonic enhanced muscle activity during REM sleep as well as the associated behaviors and vocalizations of the patients. Methods: Fifteen patients with clinical RBD underwent two consecutive video-polysomnographies. The amount of excessive phasic and tonic chin muscle activity during REM sleep was measured in 15 patients in 3-sec mini-epochs. The time spent with motor (minor, major, complex, and scenic) or vocal (sounds, mumblings, and comprehensible speeches) events was measured in 7 patients during REM sleep. Results: There was a good between-night agreement for tonic (Spearman rho = 0.55, p = 0.03; Kendall tau = 0.48, p = 0.01) but not for phasic (rho = 0.47, p = 0.1; tau = 0.31, p = 0.1) excessive chin muscle activity. On the video and audio recordings, the minor RBD behaviors tended to occur more frequently during the second night than the first, whereas the patients spoke longer during the first than the second night. Conclusion: The excessive tonic activity during REM sleep is a reliable marker of RBD. It could represent the extent of dysfunction in the permissive atonia systems. In contrast, the more variable phasic activity and motor/vocal events could be more dependent on dream content (executive systems). Citation: Cygan F; Oudiette D; Leclair-Visonneau L; Leu-Semenescu S; Arnulf I. Night-to-night variability of muscle tone, movements, and vocalizations in patients with REM sleep behavior disorder. J Clin Sleep Med 2010;6(6):551-555. PMID:21206543

  11. Changing Patterns of the Floating Population in China during 2000-2010*

    PubMed Central

    Liang, Zai; Li, Zhen; Ma, Zhongdong

    2015-01-01

    Using data from the 2000 and 2010 Chinese Population Censuses and applying a consistent definition of migration, this paper examines changing patterns of China's floating population during 2000-2010. We find that during the first decade of the 21st century, there have been significant changes in China's floating population, as reflected in continuing rise of interprovincial floating population and the rise of the floating population in China's western and interior regions, geographic diversification of destinations for the floating population, a major increase in interprovincial return migration, and significant improvement in education and occupational profiles among the floating population. We argue that these patterns are driven by a combination of complex domestic and international factors, including the newly released Labor Law, removal of agricultural tax, the western China development program, increased investment in education by the Chinese government, and the global financial crisis. We also discuss several challenges facing the floating population in the coming years, which include equality of educational opportunity for migrant children and adequate housing and social welfare protection for the floating population. Finally, we reflect on the future of migration research in China. PMID:26213427

  12. 14 CFR 25.753 - Main float design.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Main float design. 25.753 Section 25.753 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Floats and Hulls § 25.753 Main float design...

  13. 40 CFR 265.1086 - Standards: Surface impoundments.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... floating membrane cover in accordance with the provisions specified in paragraph (c) of this section; or (2... emissions from a surface impoundment using a floating membrane cover shall meet the requirements specified... with a floating membrane cover designed to meet the following specifications: (i) The floating membrane...

  14. 40 CFR 65.44 - External floating roof (EFR).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... external floating roof except for automatic bleeder vents (vacuum breaker vents) and rim space vents does... floating roof shall meet the following specifications: (i) Except for automatic bleeder vents (vacuum breaker vents) and rim space vents, each opening in the noncontact external floating roof shall provide a...

  15. 40 CFR 65.44 - External floating roof (EFR).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... external floating roof except for automatic bleeder vents (vacuum breaker vents) and rim space vents does... floating roof shall meet the following specifications: (i) Except for automatic bleeder vents (vacuum breaker vents) and rim space vents, each opening in the noncontact external floating roof shall provide a...

  16. 40 CFR 65.44 - External floating roof (EFR).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... external floating roof except for automatic bleeder vents (vacuum breaker vents) and rim space vents does... floating roof shall meet the following specifications: (i) Except for automatic bleeder vents (vacuum breaker vents) and rim space vents, each opening in the noncontact external floating roof shall provide a...

  17. Formulation and statistical optimization of gastric floating alginate/oil/chitosan capsules loading procyanidins: in vitro and in vivo evaluations.

    PubMed

    Chen, Rencai; Guo, Xiaomin; Liu, Xuecong; Cui, Haiming; Wang, Rui; Han, Jing

    2018-03-01

    The aim of the present work was to develop gastric floating capsules containing oil-entrapped beads loading procyanidins. The floating beads were prepared by ionotropic gelation method using sodium alginate, CaCl 2 and chitosan. The effect of three independent parameters (concentration of sodium alginate, CaCl 2 and chitosan) on entrapment efficiency were analyzed by Box-Behnken design. The floating beads were evaluated for surface morphology, particle size, density, entrapment efficiency, buoyancy, release behavior in vitro and floating ability in vivo. The prepared beads were grossly spherical in shape and the mean size was approximately 1.54±0.17mm. The density was 0.97g/cm 3 . And the optimal conditions were as follows: concentration of sodium alginate, CaCl 2 and chitosan were 33.75mg/mL, 9.84mg/mL and 9.05mg/mL, respectively. The optimized formulation showed entrapment efficiency of 88.84±1.04% within small error-value (0.65). The release mechanism of floating capsules followed Korsmeyer-Peppas model (r 2 =0.9902) with non-Fickian release. The gastric floating capsules exhibited 100% floating percentage in vitro and they could float on the top of gastric juice for 5h in vivo. Therefore, the floating capsules are able to prolong the gastroretentive delivery of procyanidins. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Effect of the 2011 vs 2003 duty hour regulation-compliant models on sleep duration, trainee education, and continuity of patient care among internal medicine house staff: a randomized trial.

    PubMed

    Desai, Sanjay V; Feldman, Leonard; Brown, Lorrel; Dezube, Rebecca; Yeh, Hsin-Chieh; Punjabi, Naresh; Afshar, Kia; Grunwald, Michael R; Harrington, Colleen; Naik, Rakhi; Cofrancesco, Joseph

    2013-04-22

    On July 1, 2011, the Accreditation Council for Graduate Medical Education implemented further restrictions of its 2003 regulations on duty hours and supervision. It remains unclear if the 2003 regulations improved trainee well-being or patient safety. To determine the effects of the 2011 Accreditation Council for Graduate Medical Education duty hour regulations compared with the 2003 regulations concerning sleep duration, trainee education, continuity of patient care, and perceived quality of care among internal medicine trainees. Crossover study design in an academic research setting. Medical house staff. General medical teams were randomly assigned using a sealed-envelope draw to an experimental model or a control model. We randomly assigned 4 medical house staff teams (43 interns) using a 3-month crossover design to a 2003-compliant model of every fourth night overnight call (control) with 30-hour duty limits or to one of two 2011-compliant models of every fifth night overnight call (Q5) or a night float schedule (NF), both with 16-hour duty limits. We measured sleep duration using actigraphy and used admission volumes, educational opportunities, the number of handoffs, and satisfaction surveys to assess trainee education, continuity of patient care, and perceived quality of care. RESULTS The study included 560 control, 420 Q5, and 140 NF days that interns worked and 834 hospital admissions. Compared with controls, interns on NF slept longer during the on call period (mean, 5.1 vs 8.3 hours; P = .003), and interns on Q5 slept longer during the postcall period (mean, 7.5 vs 10.2 hours; P = .05). However, both the Q5 and NF models increased handoffs, decreased availability for teaching conferences, and reduced intern presence during daytime work hours. Residents and nurses in both experimental models perceived reduced quality of care, so much so with NF that it was terminated early. Compared with a 2003-compliant model, two 2011 duty hour regulation-compliant models were associated with increased sleep duration during the on-call period and with deteriorations in educational opportunities, continuity of patient care, and perceived quality of care.

  19. Memory operations in Au nanoparticle single-electron transistors with floating gate electrodes

    NASA Astrophysics Data System (ADS)

    Azuma, Yasuo; Sakamoto, Masanori; Teranishi, Toshiharu; Majima, Yutaka

    2016-11-01

    Floating gate memory operations are demonstrated in a single-electron transistor (SET) fabricated by a chemical assembly using the Au nanogap electrodes and the chemisorbed Au nanoparticles. By applying pulse voltages to the control gate, phase shifts were clearly and stably observed both in the Coulomb oscillations and in the Coulomb diamonds. Writing and erasing operations on the floating gate memory were reproducibly observed, and the charges on the floating gate electrodes were maintained for at least 12 h. By considering the capacitance of the floating gate electrode, the number of electrons in the floating gate electrode was estimated as 260. Owing to the stability of the fabricated SET, these writing and erasing operations on the floating gate memory can be applied to reconfigurable SET circuits fabricated by a chemically assembled technique.

  20. 40 CFR 65.44 - External floating roof (EFR).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... design requirements. The owner or operator who elects to control storage vessel regulated material emissions by using an external floating roof shall comply with the design requirements listed in paragraphs (a)(1) through (3) of this section. (1) The external floating roof shall be designed to float on the...

  1. 40 CFR 65.44 - External floating roof (EFR).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... design requirements. The owner or operator who elects to control storage vessel regulated material emissions by using an external floating roof shall comply with the design requirements listed in paragraphs (a)(1) through (3) of this section. (1) The external floating roof shall be designed to float on the...

  2. 14 CFR 29.757 - Hull and auxiliary float strength.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Hull and auxiliary float strength. 29.757 Section 29.757 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... § 29.757 Hull and auxiliary float strength. The hull, and auxiliary floats if used, must withstand the...

  3. 40 CFR 63.1063 - Floating roof requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the point of refloating the floating roof shall be continuous and shall be performed as soon as... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Floating roof requirements. 63.1063...) National Emission Standards for Storage Vessels (Tanks)-Control Level 2 § 63.1063 Floating roof...

  4. 50 CFR 679.94 - Economic data report (EDR) for the Amendment 80 sector.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: NMFS, Alaska Fisheries Science Center, Economic Data Reports, 7600 Sand Point Way NE, F/AKC2, Seattle... Operation Description of code Code NMFS Alaska region ADF&G FCP Catcher/processor Floating catcher processor. FLD Mothership Floating domestic mothership. IFP Stationary Floating Processor Inshore floating...

  5. Have Floating Rates Been a Success?

    ERIC Educational Resources Information Center

    Higham, David

    1983-01-01

    Floating exchange rates have not lived up to all expectations, but neither have they performed as badly as some critics have suggested. Examined are the impact of floating rates on balance of payments adjustment, domestic economic policy, and inflation and the claim that floating rates have displayed excessive fluctuations. (Author/RM)

  6. Ada Compiler Validation Summary Report: Certificate Number 910705S1. 11192 InterAct Corporation InterAct Ada Mips Cross-Compiler System, Release 2.0 MicroVAX 3100 Cluster = Lockheed Sanders STAR MVP R3000/R3010 board (Bare Machine).

    DTIC Science & Technology

    1991-07-31

    have floating-point type declarations requiring more digits than SYSTEM.MAXDIGITS: C24113L..Y (14 tests) C35705L..Y (14 tests) C357C6L..Y (14 tests...2_147_483_648..2_147_483_647; type FLOAT is digits 6 range -2#l.0#E128.. 2#0.IIIIIIIIIIIIIIIIIIIII#El28; type LONGFLOAT is digits 15 range -2#l.0#EI024.. 2...are instan- tated into libary packages or subprograms.) F-14 Appendix F of the Ada Reference Manual F.8.1. Address Clauses for Variables Address

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Childers, M.; Barnes, J.

    The phased field development of the Lion and Panthere fields, offshore the Ivory Coast, includes a small floating production, storage, and offloading (FPSO) tanker with minimal processing capability as an early oil production system (EPS). For the long-term production scheme, the FPSO will be replaced by a converted jack up mobile offshore production system (MOPS) with full process equipment. The development also includes guyed-caisson well platforms, pipeline export for natural gas to fuel an onshore power plant, and a floating storage and offloading (FSO) tanker for oil export. Pipeline export for oil is a future possibility. This array of innovativemore » strategies and techniques seldom has been brought together in a single project. The paper describes the development plan, early oil, jack up MOPS, and transport and installation.« less

  8. Microbial Characterization of Free Floating Condensate Aboard the Mir Space Station

    NASA Technical Reports Server (NTRS)

    Ott, C. M.; Bruce, R. J.; Pierson, D. L.

    2004-01-01

    Three samples of humidity condensate that had accumulated behind panels aboard the Russian space station Mir were collected and returned to earth for analysis. As these floating masses of liquid come into contact with the astronauts and the engineering systems, they have the potential to affect both crew health and systems performance. Using a combination of culturing techniques, a wide variety of organisms were isolated included Escherichia coli, Serratia marcescens, and a presumed Legionella species. In addition, microscopic analysis indicated the presence of protozoa, dust mites, and spirochetes. These findings suggest the need for more comprehensive microbial analysis of the environment through the use of new methodologies to allow a more thorough risk assessment of spacecraft. Copyright 2004 Springer-Verlag.

  9. A floating-point digital receiver for MRI.

    PubMed

    Hoenninger, John C; Crooks, Lawrence E; Arakawa, Mitsuaki

    2002-07-01

    A magnetic resonance imaging (MRI) system requires the highest possible signal fidelity and stability for clinical applications. Quadrature analog receivers have problems with channel matching, dc offset and analog-to-digital linearity. Fixed-point digital receivers (DRs) reduce all of these problems. We have demonstrated that a floating-point DR using large (order 124 to 512) FIR low-pass filters also overcomes these problems, automatically provides long word length and has low latency between signals. A preloaded table of finite impuls response (FIR) filter coefficients provides fast switching between one of 129 different one-stage and two-stage multrate FIR low-pass filters with bandwidths between 4 KHz and 125 KHz. This design has been implemented on a dual channel circuit board for a commercial MRI system.

  10. Enhanced Night Visibility Series, Volume XVI : Phase III, Characterization of Experimental Objects

    DOT National Transportation Integrated Search

    2005-12-01

    The Enhanced Night Visibility (ENV) project is a series of experiments undertaken to investigate different visual enhancement systems (VES) for the nighttime driving task. The purpose of this characterization activity is to establish the photometric ...

  11. Formulation and in vitro evaluation of Hydrodynamically balanced system for theophylline delivery.

    PubMed

    Nayak, Amit Kumar; Malakar, Jadupati

    2011-06-01

    The objective of the present study was to formulate hydrodynamically balanced systems (HBSs) of theophylline as single unit capsules. They were formulated by physical blending of theophylline with hydroxypropyl methyl cellulose, polyethylene oxide, polyvinyl pyrrolidone, ethyl cellulose, liquid paraffin, and lactose in different ratios. These theophylline HBS capsules were evaluated for weight uniformity, drug content uniformity, in vitro floating behavior and drug release in simulated gastric fluids (pH 1.2). All these formulated HBS capsules containing theophylline were floated well over 6 hours with no floating lag time, and also showed sustained in vitro drug release in simulated gastric fluid over 6 hours. The theophylline release from these capsules was more sustained with the addition of release modifiers (ethyl cellulose and liquid paraffin). The drug release pattern from these capsules was correlated well with first order model (F-1 to F-5) and Korsmeyer-Peppas model (F-6 and F-7) with the non-Fickian (anomalous) diffusion mechanism. These experimental results clearly indicated that these theophylline HBS capsules were able to remain buoyant in the gastric juice for longer period, which may improve oral bioavailability of theophylline.

  12. Uncertainty Analysis of OC5-DeepCwind Floating Semisubmersible Offshore Wind Test Campaign

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Amy N

    This paper examines how to assess the uncertainty levels for test measurements of the Offshore Code Comparison, Continued, with Correlation (OC5)-DeepCwind floating offshore wind system, examined within the OC5 project. The goal of the OC5 project was to validate the accuracy of ultimate and fatigue load estimates from a numerical model of the floating semisubmersible using data measured during scaled tank testing of the system under wind and wave loading. The examination of uncertainty was done after the test, and it was found that the limited amount of data available did not allow for an acceptable uncertainty assessment. Therefore, thismore » paper instead qualitatively examines the sources of uncertainty associated with this test to start a discussion of how to assess uncertainty for these types of experiments and to summarize what should be done during future testing to acquire the information needed for a proper uncertainty assessment. Foremost, future validation campaigns should initiate numerical modeling before testing to guide the test campaign, which should include a rigorous assessment of uncertainty, and perform validation during testing to ensure that the tests address all of the validation needs.« less

  13. Uncertainty Analysis of OC5-DeepCwind Floating Semisubmersible Offshore Wind Test Campaign: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Amy N

    This paper examines how to assess the uncertainty levels for test measurements of the Offshore Code Comparison, Continued, with Correlation (OC5)-DeepCwind floating offshore wind system, examined within the OC5 project. The goal of the OC5 project was to validate the accuracy of ultimate and fatigue load estimates from a numerical model of the floating semisubmersible using data measured during scaled tank testing of the system under wind and wave loading. The examination of uncertainty was done after the test, and it was found that the limited amount of data available did not allow for an acceptable uncertainty assessment. Therefore, thismore » paper instead qualitatively examines the sources of uncertainty associated with this test to start a discussion of how to assess uncertainty for these types of experiments and to summarize what should be done during future testing to acquire the information needed for a proper uncertainty assessment. Foremost, future validation campaigns should initiate numerical modeling before testing to guide the test campaign, which should include a rigorous assessment of uncertainty, and perform validation during testing to ensure that the tests address all of the validation needs.« less

  14. Definition of display/control requirements for assault transport night/adverse weather capability

    NASA Technical Reports Server (NTRS)

    Milelli, R. J.; Mowery, G. W.; Pontelandolfo, C.

    1982-01-01

    A Helicopter Night Vision System was developed to improve low-altitude night and/or adverse weather assult transport capabilities. Man-in-the-loop simulation experiments were performed to define the minimum display and control requirements for the assult transport mission and investigate forward looking infrared sensor requirements, along with alternative displays such as panel mounted displays (PMD) helmet mounted displays (HMD), and integrated control display units. Also explored were navigation requirements, pilot/copilot interaction, and overall cockpit arrangement. Pilot use of an HMD and copilot use of a PMD appear as both the preferred and most effective night navigation combination.

  15. Characterization of poly(vinyl acetate) based floating matrix tablets.

    PubMed

    Strübing, Sandra; Metz, Hendrik; Mäder, Karsten

    2008-03-03

    Floating Kollidon SR matrix tablets containing Propranolol HCl were developed and characterized with respect to drug release characteristics and floating strength. Kollidon SR was able to delay Propranolol HCl release efficiently. Drug release kinetics was evaluated using the Korsmeyer-Peppas model and found to be governed by Fickian diffusion. Tablet floating started immediately and continued for 24 h. It was possible to monitor the floating strength of the matrix devices using a simple experimental setup. Floating strength was related to Kollidon SR level with improved floating characteristics for samples with a high polymer/drug ratio. Swelling characteristics of the tablets were analyzed by applying the equation according to Therien-Aubin et al. The influence of the polymer content on swelling characteristics was found to be only marginal. Furthermore, the new method of benchtop MRI was introduced to study the water diffusion and swelling behaviour non-invasively and continuously.

  16. Investigation of Tank 241-AW-104 Composite Floating Layer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meznarich, H. K.; Bolling, S. D.; Lachut, J. S.

    Seven grab samples and one field blank were taken from Tank 241-AW-104 (AW-104) on June 2, 2017, and received at 222-S Laboratory on June 5, 2017. A visible layer with brown solids was observed floating on the top of two surface tank waste samples (4AW-17-02 and 4AW 17 02DUP). The floating layer from both samples was collected, composited, and submitted for chemical analyses and solid phase characterization in order to understand the composition of the floating layer. Tributyl phosphate and tridecane were higher in the floating layer than in the aqueous phase. Density in the floating layer was slightly lowermore » than the mean density of all grab samples. Sodium nitrate and sodium carbonate were major components with a trace of gibbsite and very small size agglomerates were present in the solids of the floating layer. The supernate consisted of organics, soluble salt, and particulates.« less

  17. 33 CFR 147.815 - ExxonMobil Hoover Floating OCS Facility safety zone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false ExxonMobil Hoover Floating OCS... HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.815 ExxonMobil Hoover Floating OCS Facility safety zone. (a) Description. The ExxonMobil Hoover Floating OCS Facility, Alaminos...

  18. 33 CFR 147.815 - ExxonMobil Hoover Floating OCS Facility safety zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false ExxonMobil Hoover Floating OCS... HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.815 ExxonMobil Hoover Floating OCS Facility safety zone. (a) Description. The ExxonMobil Hoover Floating OCS Facility, Alaminos...

  19. 33 CFR 147.815 - ExxonMobil Hoover Floating OCS Facility safety zone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false ExxonMobil Hoover Floating OCS... HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.815 ExxonMobil Hoover Floating OCS Facility safety zone. (a) Description. The ExxonMobil Hoover Floating OCS Facility, Alaminos...

  20. 33 CFR 147.815 - ExxonMobil Hoover Floating OCS Facility safety zone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false ExxonMobil Hoover Floating OCS... HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.815 ExxonMobil Hoover Floating OCS Facility safety zone. (a) Description. The ExxonMobil Hoover Floating OCS Facility, Alaminos...

  1. 33 CFR 144.01-15 - Alternates for life floats.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Alternates for life floats. 144... for life floats. (a) Approved lifeboats, approved life rafts or approved inflatable life rafts may be used in lieu of approved life floats for either all or part of the capacity required. When either...

  2. 33 CFR 144.01-5 - Location and launching of life floats.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Location and launching of life floats. 144.01-5 Section 144.01-5 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Location and launching of life floats. The life floats shall be distributed in accessible locations and...

  3. 33 CFR 144.01-15 - Alternates for life floats.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Alternates for life floats. 144... for life floats. (a) Approved lifeboats, approved life rafts or approved inflatable life rafts may be used in lieu of approved life floats for either all or part of the capacity required. When either...

  4. 14 CFR 23.529 - Hull and main float landing conditions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hull and main float landing conditions. 23... Water Loads § 23.529 Hull and main float landing conditions. (a) Symmetrical step, bow, and stern... directed perpendicularly to the keel line. (b) Unsymmetrical landing for hull and single float seaplanes...

  5. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Life floats and buoyant apparatus. 131.870 Section 131... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus...

  6. 33 CFR 144.01-5 - Location and launching of life floats.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Location and launching of life floats. 144.01-5 Section 144.01-5 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Location and launching of life floats. The life floats shall be distributed in accessible locations and...

  7. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Life floats and buoyant apparatus. 131.870 Section 131... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus...

  8. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Life floats and buoyant apparatus. 131.870 Section 131... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus...

  9. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus... 46 Shipping 4 2011-10-01 2011-10-01 false Life floats and buoyant apparatus. 131.870 Section 131...

  10. 46 CFR 131.870 - Life floats and buoyant apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.870 Life floats and buoyant apparatus. (a) The name of the vessel must be plainly marked or painted on each life float or buoyant apparatus... 46 Shipping 4 2010-10-01 2010-10-01 false Life floats and buoyant apparatus. 131.870 Section 131...

  11. 77 FR 44544 - Safety Zone; Gilmerton Bridge Center Span Float-In, Elizabeth River; Norfolk, Portsmouth, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-30

    ...-AA00 Safety Zone; Gilmerton Bridge Center Span Float-In, Elizabeth River; Norfolk, Portsmouth, and... withdrawing its proposed rule concerning the Gilmerton Bridge Center Span Float-in and bridge construction of... ``Safety Zone; Gilmerton Bridge Center Span Float-in, Elizabeth River; Norfolk, Portsmouth, and Chesapeake...

  12. Night work and prostate cancer in men: a Swedish prospective cohort study.

    PubMed

    Åkerstedt, Torbjrn; Narusyte, Jurgita; Svedberg, Pia; Kecklund, Göran; Alexanderson, Kristina

    2017-06-08

    Prostate cancer is the most common cancer and the second leading cause of cancer-related deaths among men, but the contributing factors are unclear. One such may be night work because of the day/night alternation of work and the resulting disturbance of the circadian system. The purpose of the present study was to investigate the prospective relation between number of years with night work and prostate cancer in men. Cohort study comparing night and day working twins with respect to incident prostate cancer in 12 322 men. Individuals in the Swedish Twin Registry. 12 322 male twins. Prostate cancer diagnoses obtained from the Swedish Cancer Registry with a follow-up time of 12 years, with a total number of cases=454. Multiple Cox proportional hazard regression analysis, adjusted for a number of covariates, showed no association between ever night work and prostate cancer, nor for duration of night work and prostate cancer. Analysis of twin pairs discordant for prostate cancer (n=332) showed no significant association between night work and prostate cancer. The results, together with previous studies, suggest that night work does not seem to constitute a risk factor for prostate cancer. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Numerical study on aerodynamic damping of floating vertical axis wind turbines

    NASA Astrophysics Data System (ADS)

    Cheng, Zhengshun; Aagaard Madsen, Helge; Gao, Zhen; Moan, Torgeir

    2016-09-01

    Harvesting offshore wind energy resources using floating vertical axis wind turbines (VAWTs) has attracted an increasing interest in recent years. Due to its potential impact on fatigue damage, the aerodynamic damping should be considered in the preliminary design of a floating VAWT based on the frequency domain method. However, currently the study on aerodynamic damping of floating VAWTs is very limited. Due to the essential difference in aerodynamic load characteristics, the aerodynamic damping of a floating VAWT could be different from that of a floating horizontal axis wind turbine (HAWT). In this study, the aerodynamic damping of floating VAWTs was studied in a fully coupled manner, and its influential factors and its effects on the motions, especially the pitch motion, were demonstrated. Three straight-bladed floating VAWTs with identical solidity and with a blade number varying from two to four were considered. The aerodynamic damping under steady and turbulent wind conditions were estimated using fully coupled aero-hydro-servo-elastic time domain simulations. It is found that the aerodynamic damping ratio of the considered floating VAWTs ranges from 1.8% to 5.3%. Moreover, the aerodynamic damping is almost independent of the rotor azimuth angle, and is to some extent sensitive to the blade number.

  14. Approaches to Improve the Performances of the Sea Launch System Performances

    NASA Astrophysics Data System (ADS)

    Tatarevs'kyy, K.

    2002-01-01

    The paper dwells on the outlines of the techniques of on-line pre-launch analysis on possibility of safe and reliable LV launch off floating launch system, when actual launch conditions (weather, launcher motion parameters) are beyond design limitations. The technique guarantees to follow the take-off LV trajectory limitations (the shock-free launch) and allows the improvement of the operat- ing characteristics of the floating launch systems at the expense of possibility to authorize the launch even if a number of weather and launcher motion parameters restrictions are exceeded. This paper ideas are applied for LV of Zenit-type launches off tilting launch platform, operative within Sea Launch. The importance, novelty and urgency of the approach under consideration is explained by the fact that the application during floating launch systems operation allows the bringing down of the num- ber of weather-conditioned launch abort cases. And this, in its part, increases the trustworthiness of the mission fulfillment on specific spacecraft injection, since, in the long run, the launch abort may cause the crossing of allowable wait threshold and accordingly the mission abort. All previous launch kinds for these LV did not require the development of the special technique of pre-launch analysis on launch possibility, since weather limitations for stationary launcher condi- tions are basically reduced to the wind velocity limitations. This parameter is reliably monitored and is sure to influence the launch dynamics. So the measured wind velocity allows the thorough picture on the possibility of the launch off the ground-based launcher. Since the floating launch systems commit complex and continuous movements under the exposure of the wind and the waves, the number of parameters is increased and, combined differently, they do not always make the issue on shockless launch critical. The proposed technique of the pre-launch analysis of the forthcoming launch dynamics with the consideration of the launch conditions (weather, launcher motion parameters, actual LV and carried SC performance) allow the evaluation of the actual combination of launch environment influence on the possibility of shockless launch. On the basis of the analysis the launch permissibility deci- sion is taken, even if some separate parameters are beyond the design range.

  15. Ixpantepec Nieves Mixtec Word Prosody

    NASA Astrophysics Data System (ADS)

    Carroll, Lucien Serapio

    This dissertation presents a phonological description and acoustic analysis of the word prosody of Ixpantepec Nieves Mixtec, which involves both a complex tone system and a default stress system. The analysis of Nieves Mixtec word prosody is complicated by a close association between morphological structure and prosodic structure, and by the interactions between word prosody and phonation type, which has both contrastive and non-contrastive roles in the phonology. I contextualize these systems within the phonology of Nieves Mixtec as a whole, within the literature on other Mixtec varieties, and within the literature on cross-linguistic prosodic typology. The literature on prosodic typology indicates that stress is necessarily defined abstractly, as structured prominence realized differently in each language. Descriptions of stress in other Mixtec varieties widely report default stress on the initial syllable of the canonical bimoraic root, though some descriptions suggest final stress or mobile stress. I first present phonological evidence---from distributional restrictions, phonological processes, and loanword adaptation---that Nieves Mixtec word prosody does involve a stress system, based on trochaic feet aligned to the root. I then present an acoustic study comparing stressed syllables to unstressed syllables, for ten potential acoustic correlates of stress. The results indicate that the acoustic correlates of stress in Nieves Mixtec include segmental duration, intensity and periodicity. Building on analyses of other Mixtec tone systems, I show that the distribution of tone and the tone processes in Nieves Mixtec support an analysis in which morae may bear H, M or L tone, where M tone is underlyingly unspecified, and each morpheme may sponsor a final +H or +L floating tone. Bimoraic roots thus host up to two linked tones and one floating tone, while monomoraic clitics host just one linked tone and one floating tone, and tonal morphemes are limited to a single floating tone. I then present three studies describing the acoustic realization of tone and comparing the realization of tone in different prosodic types. The findings of these studies include a strong directional asymmetry in tonal coarticulation, increased duration at the word or phrase boundary, phonation differences among the tone categories, and F0 differences between the glottalization categories.

  16. Impact of anti-tacking agents on properties of gas-entrapped membrane and effervescent floating tablets.

    PubMed

    Kriangkrai, Worawut; Puttipipatkhachorn, Satit; Sriamornsak, Pornsak; Pongjanyakul, Thaned; Sungthongjeen, Srisagul

    2014-12-01

    Tackiness caused by the gas-entrapped membrane (Eudragit(®)RL 30D) was usually observed during storage of the effervescent floating tablets, leading to failure in floatation and sustained release. In this work, common anti-tacking agents (glyceryl monostearate (GMS) and talc) were used to solve this tackiness problem. The impact of anti-tacking agent on the properties of free films and corresponding floating tablets was investigated. GMS was more effective than talc in reducing tackiness of the film. Addition and increasing amount of anti-tacking agents lowered the film mechanical strength, but the coating films were still strong and flexible enough to resist the generated gas pressure inside the floating tablet. Wettability and water vapor permeability of the film decreased with increasing level of anti-tacking agents as a result of their hydrophobicity. No interaction between anti-tacking agents and polymer was observed as confirmed by Fourier transform infrared spectroscopy, powder X-ray diffractometry, and differential scanning calorimetry studies. Increasing amount of anti-tacking agents decreased time to float and tended to retard drug release of the floating tablets. Floating properties and drug release were also influenced by type of anti-tacking agents. The obtained floating tablets still possessed good floating properties and controlled drug release even though anti-tacking agent had some effects. The results demonstrated that the tackiness problem of the floating tablets could be solved by incorporating anti-tacking agent into the gas-entrapped membrane.

  17. Characterization of airborne float coal dust emitted during continuous mining, longwall mining and belt transport.

    PubMed

    Shahan, M R; Seaman, C E; Beck, T W; Colinet, J F; Mischler, S E

    2017-09-01

    Float coal dust is produced by various mining methods, carried by ventilating air and deposited on the floor, roof and ribs of mine airways. If deposited, float dust is re-entrained during a methane explosion. Without sufficient inert rock dust quantities, this float coal dust can propagate an explosion throughout mining entries. Consequently, controlling float coal dust is of critical interest to mining operations. Rock dusting, which is the adding of inert material to airway surfaces, is the main control technique currently used by the coal mining industry to reduce the float coal dust explosion hazard. To assist the industry in reducing this hazard, the Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health initiated a project to investigate methods and technologies to reduce float coal dust in underground coal mines through prevention, capture and suppression prior to deposition. Field characterization studies were performed to determine quantitatively the sources, types and amounts of dust produced during various coal mining processes. The operations chosen for study were a continuous miner section, a longwall section and a coal-handling facility. For each of these operations, the primary dust sources were confirmed to be the continuous mining machine, longwall shearer and conveyor belt transfer points, respectively. Respirable and total airborne float dust samples were collected and analyzed for each operation, and the ratio of total airborne float coal dust to respirable dust was calculated. During the continuous mining process, the ratio of total airborne float coal dust to respirable dust ranged from 10.3 to 13.8. The ratios measured on the longwall face were between 18.5 and 21.5. The total airborne float coal dust to respirable dust ratio observed during belt transport ranged between 7.5 and 21.8.

  18. Night-to-night variability of muscle tone, movements, and vocalizations in patients with REM sleep behavior disorder.

    PubMed

    Cygan, Fanny; Oudiette, Delphine; Leclair-Visonneau, Laurène; Leu-Semenescu, Smaranda; Arnulf, Isabelle

    2010-12-15

    The video-polysomnographic criteria of REM sleep behavior disorder (RBD) have not been well described. We evaluated the between-night reproducibility of phasic and tonic enhanced muscle activity during REM sleep as well as the associated behaviors and vocalizations of the patients. Fifteen patients with clinical RBD underwent two consecutive video-polysomnographies. The amount of excessive phasic and tonic chin muscle activity during REM sleep was measured in 15 patients in 3-sec mini-epochs. The time spent with motor (minor, major, complex, and scenic) or vocal (sounds, mumblings, and comprehensible speeches) events was measured in 7 patients during REM sleep. There was a good between-night agreement for tonic (Spearman rho = 0.55, p = 0.03; Kendall tau = 0.48, p = 0.01) but not for phasic (rho = 0.47, p = 0.1; tau = 0.31, p = 0.1) excessive chin muscle activity. On the video and audio recordings, the minor RBD behaviors tended to occur more frequently during the second night than the first, whereas the patients spoke longer during the first than the second night. The excessive tonic activity during REM sleep is a reliable marker of RBD. It could represent the extent of dysfunction in the permissive atonia systems. In contrast, the more variable phasic activity and motor/vocal events could be more dependent on dream content (executive systems).

  19. Late-night exercise affects the autonomic nervous system activity but not the hypothalamo-pituitary-adrenal axis in the next morning.

    PubMed

    Uçar, Cihat; Özgöçer, Tuba; Yildiz, Sedat

    2018-01-01

    Exercise activates hypothalamic-pituitary-adrenal axis (HPA) and autonomic nervous system (ANS) and generally causes beneficial changes in homeostatic balance. However, the health benefits of late-night exercise programs on the activity of HPA and ANS is not known. The aim of this study was to assess effects of late-night exercise on sleep quality and on the activities of the HPA axis (as cortisol awakening response, CAR) and the ANS (as heart rate variability, HRV) measurements in the following morning. Medical students (N.=20 males, 20-24 years old) filled Karolinska Sleep Diary on the day before exercise program. In the following morning, they provided salivary samples for the assessment of CAR (samples at 0, 15, 30 and 60 min postawakening) and had a 5-min electrocardiogram recording for the determination of HRV. In the next night, an exercise program consisting of a 90-min football match was implemented at 09:30 p.m. and all procedures were repeated. Cortisol concentrations were measured in the salivary samples and time- and frequency-domain parameters of HRV were calculated. Late-night exercise did not affect (P>0.05) sleep parameters (sleep duration, disturbed sleep, awakening problems) and CAR parameters (0, 15, 30, 60 min cortisol concentrations, mean concentration, area under the curve) but influenced HRV parameters (P<0.05). The results suggest that late-night exercise is associated with changed HRV activity rather than changes in CAR and, therefore, it might be suggested that late-night exercise affects ANS activity rather than HPA activity in the next morning.

  20. Cold-induced bradycardia in man during sleep in Arctic winter nights

    NASA Astrophysics Data System (ADS)

    Buguet, A. G. C.

    1987-03-01

    Two young male Caucasians volunteered for a study on the effects of cold exposure during night sleep in winter in the Arctic. The 14-day experiment was divided in three consecutive periods, baseline (2 nights), cold exposure (10 night) and recovery (2 nights). Both baseline and recovery data were obtained in neutral thermal conditions in a laboratory. The subjects slept in a sleeping bag under an unheated tent during the cold exposure. Apart from polysomnographic and body temperature recordings, electrocardiograms were taken through a telemetric system for safety purposes. Heart rates were noted at 5-min intervals and averaged hourly. In both environmental conditions, heart rate decreased within the first two hours of sleep. Comparison of the data obtained during cold exposure vs. thermal neutrality revealed lower values of heart rate in the cold, while body temperatures remained within normal range. This cold-induced bradycardia supervening during night sleep is discussed in terms of the occurrence of a vagal reflex preventing central blood pressure to rise.

Top