Helicopter flights with night-vision goggles: Human factors aspects
NASA Technical Reports Server (NTRS)
Brickner, Michael S.
1989-01-01
Night-vision goggles (NVGs) and, in particular, the advanced, helmet-mounted Aviators Night-Vision-Imaging System (ANVIS) allows helicopter pilots to perform low-level flight at night. It consists of light intensifier tubes which amplify low-intensity ambient illumination (star and moon light) and an optical system which together produce a bright image of the scene. However, these NVGs do not turn night into day, and, while they may often provide significant advantages over unaided night flight, they may also result in visual fatigue, high workload, and safety hazards. These problems reflect both system limitations and human-factors issues. A brief description of the technical characteristics of NVGs and of human night-vision capabilities is followed by a description and analysis of specific perceptual problems which occur with the use of NVGs in flight. Some of the issues addressed include: limitations imposed by a restricted field of view; problems related to binocular rivalry; the consequences of inappropriate focusing of the eye; the effects of ambient illumination levels and of various types of terrain on image quality; difficulties in distance and slope estimation; effects of dazzling; and visual fatigue and superimposed symbology. These issues are described and analyzed in terms of their possible consequences on helicopter pilot performance. The additional influence of individual differences among pilots is emphasized. Thermal imaging systems (forward looking infrared (FLIR)) are described briefly and compared to light intensifier systems (NVGs). Many of the phenomena which are described are not readily understood. More research is required to better understand the human-factors problems created by the use of NVGs and other night-vision aids, to enhance system design, and to improve training methods and simulation techniques.
2005-03-01
off-label use of custom wavefront-guided treatment has demonstrated potential for reducing some QoV problems; however, early custom- ablation LASIK ...10): 1934-40. 66. Lee JB, Ryu CH, Kim EK,, Kim HB. Comparison of tear secretion and tear film instability after PRK and LASIK . J Cataract Surg
Night vision and electro-optics technology transfer, 1972 - 1981
NASA Astrophysics Data System (ADS)
Fulton, R. W.; Mason, G. F.
1981-09-01
The purpose of this special report, 'Night Vision and Electro-Optics Technology Transfer 1972-1981,' is threefold: To illustrate, through actual case histories, the potential for exploiting a highly developed and available military technology for solving non-military problems. To provide, in a layman's language, the principles behind night vision and electro-optical devices in order that an awareness may be developed relative to the potential for adopting this technology for non-military applications. To obtain maximum dollar return from research and development investments by applying this technology to secondary applications. This includes, but is not limited to, applications by other Government agencies, state and local governments, colleges and universities, and medical organizations. It is desired that this summary of Technology Transfer activities within Night Vision and Electro-Optics Laboratory (NV/EOL) will benefit those who desire to explore one of the vast technological resources available within the Defense Department and the Federal Government.
Night Vision Manual for the Flight Surgeon.
1985-08-01
by optic nerve and pathways to Brodmann’s occipital areas 17 and 18). Perception occurs - vision Sensitive material ( retinal pigment) must be...clearly may be defined as glare. Glare becomes a problem in patients with opacities of the ocular media or with retinal diseases. 3 FME tN [I.I Sl IN FM...reduction of pupillary area caused by the drug. 3. Retinal causes of abnormal dark adaptation. a. Congenital stationary night blindness. b. etinitis
Vision and night driving abilities of elderly drivers.
Gruber, Nicole; Mosimann, Urs P; Müri, René M; Nef, Tobias
2013-01-01
In this article, we review the impact of vision on older people's night driving abilities. Driving is the preferred and primary mode of transport for older people. It is a complex activity where intact vision is seminal for road safety. Night driving requires mesopic rather than scotopic vision, because there is always some light available when driving at night. Scotopic refers to night vision, photopic refers to vision under well-lit conditions, and mesopic vision is a combination of photopic and scotopic vision in low but not quite dark lighting situations. With increasing age, mesopic vision decreases and glare sensitivity increases, even in the absence of ocular diseases. Because of the increasing number of elderly drivers, more drivers are affected by night vision difficulties. Vision tests, which accurately predict night driving ability, are therefore of great interest. We reviewed existing literature on age-related influences on vision and vision tests that correlate or predict night driving ability. We identified several studies that investigated the relationship between vision tests and night driving. These studies found correlations between impaired mesopic vision or increased glare sensitivity and impaired night driving, but no correlation was found among other tests; for example, useful field of view or visual field. The correlation between photopic visual acuity, the most commonly used test when assessing elderly drivers, and night driving ability has not yet been fully clarified. Photopic visual acuity alone is not a good predictor of night driving ability. Mesopic visual acuity and glare sensitivity seem relevant for night driving. Due to the small number of studies evaluating predictors for night driving ability, further research is needed.
ERIC Educational Resources Information Center
Zebehazy, Kim T.; Zimmerman, George J.; Bowers, Alex R.; Luo, Gang; Peli, Eli
2005-01-01
In addition to their restricted peripheral fields, persons with retinitis pigmentosa (RP) report significant problems seeing in low levels of illumination, which causes difficulty with night travel. Several devices have been developed to support the visual needs of persons who have night blindness. These devices include wide-angle flashlights,…
Night vision: requirements and possible roadmap for FIR and NIR systems
NASA Astrophysics Data System (ADS)
Källhammer, Jan-Erik
2006-04-01
A night vision system must increase visibility in situations where only low beam headlights can be used today. As pedestrians and animals have the highest risk increase in night time traffic due to darkness, the ability of detecting those objects should be the main performance criteria, and the system must remain effective when facing the headlights of oncoming vehicles. Far infrared system has been shown to be superior to near infrared system in terms of pedestrian detection distance. Near infrared images were rated to have significantly higher visual clutter compared with far infrared images. Visual clutter has been shown to correlate with reduction in detection distance of pedestrians. Far infrared images are perceived as being more unusual and therefore more difficult to interpret, although the image appearance is likely related to the lower visual clutter. However, the main issue comparing the two technologies should be how well they solve the driver's problem with insufficient visibility under low beam conditions, especially of pedestrians and other vulnerable road users. With the addition of an automatic detection aid, a main issue will be whether the advantage of FIR systems will vanish given NIR systems with well performing automatic pedestrian detection functionality. The first night vision introductions did not generate the sales volumes initially expected. A renewed interest in night vision systems are however to be expected after the release of night vision systems by BMW, Mercedes and Honda, the latter with automatic pedestrian detection.
Connecting Research on Retinitis Pigmentosa to the Practice of Orientation and Mobility.
ERIC Educational Resources Information Center
Geruschat, Duane R.; Turano, Kathleen A.
2002-01-01
Retinitis pigmentosa (RP) causes restriction of the visual field, progressive vision loss, and night blindness. This article presents an overview of the most common problems in orientation and mobility (O&M) for individuals with RP, appropriate interventions, vision science discoveries related to RP, and the impact of RP on functional visual…
Aural-Nondetectability Model Predictions for Night-Vision Goggles across Ambient Lighting Conditions
2015-12-01
ARL-TR-7564 ● DEC 2015 US Army Research Laboratory Aural-Nondetectability Model Predictions for Night -Vision Goggles across...ARL-TR-7564 ● DEC 2015 US Army Research Laboratory Aural-Nondetectability Model Predictions for Night -Vision Goggles across Ambient...May 2015–30 Sep 2015 4. TITLE AND SUBTITLE Aural-Nondetectability Model Predictions for Night -Vision Goggles across Ambient Lighting Conditions 5a
... walking through a dark room, such as a movie theater. These problems are often worse just after ... Lippincott Williams & Wilkins; 2013:vol 3, chap 2. Review Date 8/20/2016 Updated by: Franklin W. ...
Night vision: changing the way we drive
NASA Astrophysics Data System (ADS)
Klapper, Stuart H.; Kyle, Robert J. S.; Nicklin, Robert L.; Kormos, Alexander L.
2001-03-01
A revolutionary new Night Vision System has been designed to help drivers see well beyond their headlights. From luxury automobiles to heavy trucks, Night Vision is helping drivers see better, see further, and react sooner. This paper describes how Night Vision Systems are being used in transportation and their viability for the future. It describes recent improvements to the system currently in the second year of production. It also addresses consumer education and awareness, cost reduction, product reliability, market expansion and future improvements.
Visual Problems in Night Operations (Problemes de Vision dans les Operations de Nuit)
1992-05-01
appeared devices, true night war fighting capability has at in the early 1980s . For the first time, a device last become a reality (as demonstrated in the...gn6gralement us changement do niveau d’aspiration dans ie resultat do Re 4-SYSTMES MULTI-SENSEURS ET Mt:CANIS- tiche. Par exemple Sp6randio ( 1980 ) montro...I1 faut SPERANDIO J.C.( 1980 ) La psychologie en ergonomie, donc cerner ce qui reste effectivement rtalisable de nuit PUF le Psychologue, Paris. clans le
Autonomous Intersection Management
2009-12-01
is irrelevant. Fortunately, researchers are attacking this problem with many techniques. In 2004, Honda introduced an intelligent night vision system...or less a solved problem . The problem itself is not too difficult: there are no pedestrians or cyclists and vehicles travel in the same direction at...organized according to the following subgoals, each of which is a contribution of the thesis. 1. Problem definition First, this thesis contributes a
14 CFR 61.31 - Type rating requirements, additional training, and authorization requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... holder is already qualified. (k) Additional training required for night vision goggle operations. (1... aircraft using night vision goggles only if that person receives and logs ground training from an...: (i) Applicable portions of this chapter that relate to night vision goggle limitations and flight...
14 CFR 61.31 - Type rating requirements, additional training, and authorization requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... holder is already qualified. (k) Additional training required for night vision goggle operations. (1... aircraft using night vision goggles only if that person receives and logs ground training from an...: (i) Applicable portions of this chapter that relate to night vision goggle limitations and flight...
Night Vision Goggle Training; Development and Production of Six Video Programs
1992-11-01
SUIUECT TERMS Multimedia Video production iS. NUMBER OF PAGES Aeral photography Night vision Videodisc 18 Image Intensification Night vision goggles...reference tool on the squadron or wing demonstrates NVG field of view, field of level. The programs run approximately ten regard, scan techniques, image...training device modalities. These The production of a videodisc that modalities include didactic and video will serve as an NVG audio-visual database
Optical Characterization of Wide Field-of-View Night Vision Devices
1999-01-01
This paper has been cleared by ASC 99-2354 Optical Characterization of Wide Field-Of-View Night Vision Devices Peter L. Marasco and H. Lee Task Air...the SAFE SocietyÕs 36th Annual Symposium. Task, H.L., Hartman, R., Marasco , P.L., Zobel, A, (1993) Methods for measuring characteristics of night
Jian, Bo-Lin; Peng, Chao-Chung
2017-06-15
Due to the direct influence of night vision equipment availability on the safety of night-time aerial reconnaissance, maintenance needs to be carried out regularly. Unfortunately, some defects are not easy to observe or are not even detectable by human eyes. As a consequence, this study proposed a novel automatic defect detection system for aviator's night vision imaging systems AN/AVS-6(V)1 and AN/AVS-6(V)2. An auto-focusing process consisting of a sharpness calculation and a gradient-based variable step search method is applied to achieve an automatic detection system for honeycomb defects. This work also developed a test platform for sharpness measurement. It demonstrates that the honeycomb defects can be precisely recognized and the number of the defects can also be determined automatically during the inspection. Most importantly, the proposed approach significantly reduces the time consumption, as well as human assessment error during the night vision goggle inspection procedures.
2014-01-01
a similar problem. See Robert Jackall , Moral Mazes: The World of Corporate Managers, London: Oxford University Press, 2009. Contractor Incentives...Night Vision Goggles,” ITT Corporation press release, April 4, 2011. Jackall , Robert, Moral Mazes: The World of Corporate Managers, London: Oxford
Low Cost Night Vision System for Intruder Detection
NASA Astrophysics Data System (ADS)
Ng, Liang S.; Yusoff, Wan Azhar Wan; R, Dhinesh; Sak, J. S.
2016-02-01
The growth in production of Android devices has resulted in greater functionalities as well as lower costs. This has made previously more expensive systems such as night vision affordable for more businesses and end users. We designed and implemented robust and low cost night vision systems based on red-green-blue (RGB) colour histogram for a static camera as well as a camera on an unmanned aerial vehicle (UAV), using OpenCV library on Intel compatible notebook computers, running Ubuntu Linux operating system, with less than 8GB of RAM. They were tested against human intruders under low light conditions (indoor, outdoor, night time) and were shown to have successfully detected the intruders.
Assessment of New Marksmanship Strategies in 2010
2012-03-01
and 4N (CCO used during the day; Night vision device/goggles and AN/ PAQ -4 aiming light used at night) DAY FIRING PRONE SUPPORTED PRONE...Boresighting/zeroing an aiming light ( PAQ / PEQ) Y N Did not perform b. Boresighting/zeroing a CCO % Soldiers responding to each option OSUT 1 OSUT...magazines while engaging targets Y N g. Engaging targets at night with an aiming light ( PAQ /PEQ) and night vision goggles/device Y N h. Engaging
Aviator's night vision system (ANVIS) in Operation Enduring Freedom (OEF): user acceptability survey
NASA Astrophysics Data System (ADS)
Hiatt, Keith L.; Trollman, Christopher J.; Rash, Clarence E.
2010-04-01
In 1973, the U.S. Army adopted night vision devices for use in the aviation environment. These devices are based on the principle of image intensification (I2) and have become the mainstay for the aviator's capability to operate during periods of low illumination, i.e., at night. In the nearly four decades that have followed, a number of engineering advancements have significantly improved the performance of these devices. The current version, using 3rd generation I2 technology is known as the Aviator's Night Vision Imaging System (ANVIS). While considerable experience with performance has been gained during training and peacetime operations, no previous studies have looked at user acceptability and performance issues in a combat environment. This study was designed to compare Army Aircrew experiences in a combat environment to currently available information in the published literature (all peacetime laboratory and field training studies) and to determine if the latter is valid. The purpose of this study was to identify and assess aircrew satisfaction with the ANVIS and any visual performance issues or problems relating to its use in Operation Enduring Freedom (OEF). The study consisted of an anonymous survey (based on previous validated surveys used in the laboratory and training environments) of 86 Aircrew members (64% Rated and 36% Non-rated) of an Aviation Task Force approximately 6 months into their OEF deployment. This group represents an aggregate of >94,000 flight hours of which ~22,000 are ANVIS and ~16,000 during this deployment. Overall user acceptability of ANVIS in a combat environment will be discussed.
Evaluation of visual acuity with Gen 3 night vision goggles
NASA Technical Reports Server (NTRS)
Bradley, Arthur; Kaiser, Mary K.
1994-01-01
Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.
Night myopia is reduced in binocular vision.
Chirre, Emmanuel; Prieto, Pedro M; Schwarz, Christina; Artal, Pablo
2016-06-01
Night myopia, which is a shift in refraction with light level, has been widely studied but still lacks a complete understanding. We used a new infrared open-view binocular Hartmann-Shack wave front sensor to quantify night myopia under monocular and natural binocular viewing conditions. Both eyes' accommodative response, aberrations, pupil diameter, and convergence were simultaneously measured at light levels ranging from photopic to scotopic conditions to total darkness. For monocular vision, reducing the stimulus luminance resulted in a progression of the accommodative state that tends toward the subject's dark focus or tonic accommodation and a change in convergence following the induced accommodative error. Most subjects presented a myopic shift of accommodation that was mitigated in binocular vision. The impact of spherical aberration on the focus shift was relatively small. Our results in monocular conditions support the hypothesis that night myopia has an accommodative origin as the eye progressively changes its accommodation state with decreasing luminance toward its resting state in total darkness. On the other hand, binocularity restrains night myopia, possibly by using fusional convergence as an additional accommodative cue, thus reducing the potential impact of night myopia on vision at low light levels.
Moulded infrared optics making night vision for cars within reach
NASA Astrophysics Data System (ADS)
Bourget, Antoine; Guimond, Yann; Franks, John; Van Den Bergh, Marleen
2005-02-01
Sustainable mobility is a major public concern, making increased safety one of the major challenges for the car of the future. About half of all serious traffic accidents occur at night, while only a minority of journeys is at night. Reduced visibility is one of the main reasons for these striking statistics and this explains the interest of the automobile industry in Enhanced Night Vision Systems. As an answer to the need for high volume, low cost optics for these applications, Umicore has developed GASIR. This material is transparent in the NEAR and FAR infrared, and is mouldable into high quality finished spherical, aspherical and diffractive lenses. Umicore's GASIR moulded lenses are an ideal solution for thermal imaging for cars (Night Vision) and for sensing systems like pedestrian detection, collision avoidance, occupation detection, intelligent airbag systems etc.
Night Vision Manual for the Flight Surgeon
1992-08-01
may cause night blindness are glaucoma, progressive cone/rod dystrophies (e.g., retinitis pigmentosa , Stargardt’s disease), drug toxicity (e.g...Alabama, July 1989. 38. Berson EL, Rabin AR, Mehaffey L. Advances in night vision twchnology: A pocketscope for patients with retinitis pigmentosa ... retinal sensitivity to dim light. Regeneration of the photopigments occurs during dark adaptation. The fully dark-adapted eye, in which photopigment
Night Vision Laboratory Static Performance Model for Thermal Viewing Systems
1975-04-01
Research and Development Technical Report f ECOM- • i’.__1’=• =•NIGHT VISION LABORATORY STATIC PERFORMANCE MODEL 1 S1=• : FOR THERMAL VIEWING...resolvable temperature Infrared imaging Minimum detectable temperature1.Detection and recognition performance Night visi,-)n Noise equivalent temperature...modulation transfer function (MTF). The noise charactcristics are specified by the noise equivalent temper- ature difference (NE AT), The next sections
Insect photoreceptor adaptations to night vision
Honkanen, Anna; Salmela, Iikka; Weckström, Matti
2017-01-01
Night vision is ultimately about extracting information from a noisy visual input. Several species of nocturnal insects exhibit complex visually guided behaviour in conditions where most animals are practically blind. The compound eyes of nocturnal insects produce strong responses to single photons and process them into meaningful neural signals, which are amplified by specialized neuroanatomical structures. While a lot is known about the light responses and the anatomical structures that promote pooling of responses to increase sensitivity, there is still a dearth of knowledge on the physiology of night vision. Retinal photoreceptors form the first bottleneck for the transfer of visual information. In this review, we cover the basics of what is known about physiological adaptations of insect photoreceptors for low-light vision. We will also discuss major enigmas of some of the functional properties of nocturnal photoreceptors, and describe recent advances in methodologies that may help to solve them and broaden the field of insect vision research to new model animals. This article is part of the themed issue ‘Vision in dim light’. PMID:28193821
Helmet-mounted pilot night vision systems: Human factors issues
NASA Technical Reports Server (NTRS)
Hart, Sandra G.; Brickner, Michael S.
1989-01-01
Helmet-mounted displays of infrared imagery (forward-looking infrared (FLIR)) allow helicopter pilots to perform low level missions at night and in low visibility. However, pilots experience high visual and cognitive workload during these missions, and their performance capabilities may be reduced. Human factors problems inherent in existing systems stem from three primary sources: the nature of thermal imagery; the characteristics of specific FLIR systems; and the difficulty of using FLIR system for flying and/or visually acquiring and tracking objects in the environment. The pilot night vision system (PNVS) in the Apache AH-64 provides a monochrome, 30 by 40 deg helmet-mounted display of infrared imagery. Thermal imagery is inferior to television imagery in both resolution and contrast ratio. Gray shades represent temperatures differences rather than brightness variability, and images undergo significant changes over time. The limited field of view, displacement of the sensor from the pilot's eye position, and monocular presentation of a bright FLIR image (while the other eye remains dark-adapted) are all potential sources of disorientation, limitations in depth and distance estimation, sensations of apparent motion, and difficulties in target and obstacle detection. Insufficient information about human perceptual and performance limitations restrains the ability of human factors specialists to provide significantly improved specifications, training programs, or alternative designs. Additional research is required to determine the most critical problem areas and to propose solutions that consider the human as well as the development of technology.
Tan, Xue; Aoki, Aya; Yanagi, Yasuo
2013-01-01
Patients with the complete form of congenital stationary night blindness (CSNB) often have reduced visual acuity, myopia, impaired night vision, and sometimes nystagmus and strabismus, however, they seldom complain of color vision abnormality. A 17-year-old male who was at technical school showed abnormalities in the color perception test for employment, and was referred to our hospital for a detailed examination. He had no family history of color vision deficiency and no other symptoms. During the initial examination, his best-corrected visual acuity was 1.2 in both eyes. His fundus showed no abnormalities except for somewhat yellowish reflex in the fovea of both eyes. Electroretinogram (ERG) showed a good response in cone ERG and 30 Hz flicker ERG, however, the bright flash, mixed rod and cone ERG showed a negative type with a reduced b-wave (positive deflection). There was no response in the rod ERG, either. From the findings of the typical ERG, the patient was diagnosed with complete congenital stationary night blindness. This case underscores the importance of ERG in order to diagnose the cause of a color vision anomaly.
2007-07-01
SAS System Analysis and Studies Panel • SCI Systems Concepts and Integration Panel • SET Sensors and Electronics Technology Panel These...Daylight Readability 4-2 4.1.4 Night-Time Readability 4-2 4.1.5 NVIS Radiance 4-2 4.1.6 Human Factors Analysis 4-3 4.1.7 Flight Tests 4-3 4.1.7.1...position is shadowing. Moonlight creates shadows during night-time just as sunlight does during the day. Understanding what cannot be seen in night-time
Kalt, Wilhelmina; McDonald, Jane E; Fillmore, Sherry A E; Tremblay, Francois
2014-11-19
Clinical evidence for anthocyanin benefits in night vision is controversial. This paper presents two human trials investigating blueberry anthocyanin effects on dark adaptation, functional night vision, and vision recovery after retinal photobleaching. One trial, S2 (n = 72), employed a 3 week intervention and a 3 week washout, two anthocyanin doses (271 and 7.11 mg cyanidin 3-glucoside equivalents (C3g eq)), and placebo. The other trial, L1 (n = 59), employed a 12 week intervention and an 8 week washout and tested one dose (346 mg C3g eq) and placebo. In both S2 and L1 neither dark adaptation nor night vision was improved by anthocyanin intake. However, in both trials anthocyanin consumption hastened the recovery of visual acuity after photobleaching. In S2 both anthocyanin doses were effective (P = 0.014), and in L1 recovery was improved at 8 weeks (P = 0.027) and 12 weeks (P = 0.030). Although photobleaching recovery was hastened by anthocyanins, it is not known whether this improvement would have an impact on everyday vision.
Insect photoreceptor adaptations to night vision.
Honkanen, Anna; Immonen, Esa-Ville; Salmela, Iikka; Heimonen, Kyösti; Weckström, Matti
2017-04-05
Night vision is ultimately about extracting information from a noisy visual input. Several species of nocturnal insects exhibit complex visually guided behaviour in conditions where most animals are practically blind. The compound eyes of nocturnal insects produce strong responses to single photons and process them into meaningful neural signals, which are amplified by specialized neuroanatomical structures. While a lot is known about the light responses and the anatomical structures that promote pooling of responses to increase sensitivity, there is still a dearth of knowledge on the physiology of night vision. Retinal photoreceptors form the first bottleneck for the transfer of visual information. In this review, we cover the basics of what is known about physiological adaptations of insect photoreceptors for low-light vision. We will also discuss major enigmas of some of the functional properties of nocturnal photoreceptors, and describe recent advances in methodologies that may help to solve them and broaden the field of insect vision research to new model animals.This article is part of the themed issue 'Vision in dim light'. © 2017 The Author(s).
NASA Astrophysics Data System (ADS)
McDowell, M. W.; Klee, H. W.
1986-02-01
The use of the zero power corrector concept has been extended to the design of objective lenses and magnifiers suitable for use in night vision goggles. A novel design which can be used as either an f/1.2 objective or an f/2 magnifier is also described.
Peripheral vision horizon display on the single seat night attack A-10
NASA Technical Reports Server (NTRS)
Nims, D. F.
1984-01-01
The concept of the peripheral vision horizon display (PVHD) held promise for significant reduction in workload for the single seat night attack pilot. For this reason it was incorporated in the single seat night attack (SSNA) A-10. The implementation and results of the PVHD on the SSNA A-10 are discussed as well as the SSNA program. The part the PVHD played in the test and the results and conclusions of that effort are also considered.
Advanced helmet vision system (AHVS) integrated night vision helmet mounted display (HMD)
NASA Astrophysics Data System (ADS)
Ashcraft, Todd W.; Atac, Robert
2012-06-01
Gentex Corporation, under contract to Naval Air Systems Command (AIR 4.0T), designed the Advanced Helmet Vision System to provide aircrew with 24-hour, visor-projected binocular night vision and HMD capability. AHVS integrates numerous key technologies, including high brightness Light Emitting Diode (LED)-based digital light engines, advanced lightweight optical materials and manufacturing processes, and innovations in graphics processing software. This paper reviews the current status of miniaturization and integration with the latest two-part Gentex modular helmet, highlights the lessons learned from previous AHVS phases, and discusses plans for qualification and flight testing.
NASA Technical Reports Server (NTRS)
1996-01-01
PixelVision, Inc. developed the Night Video NV652 Back-illuminated CCD Camera, based on the expertise of a former Jet Propulsion Laboratory employee and a former employee of Scientific Imaging Technologies, Inc. The camera operates without an image intensifier, using back-illuminated and thinned CCD technology to achieve extremely low light level imaging performance. The advantages of PixelVision's system over conventional cameras include greater resolution and better target identification under low light conditions, lower cost and a longer lifetime. It is used commercially for research and aviation.
NASA Technical Reports Server (NTRS)
Hart, Sandra G.
1988-01-01
The state-of-the-art helicopter and its pilot are examined using the tools of human-factors analysis. The significant role of human error in helicopter accidents is discussed; the history of human-factors research on helicopters is briefly traced; the typical flight tasks are described; and the noise, vibration, and temperature conditions typical of modern military helicopters are characterized. Also considered are helicopter controls, cockpit instruments and displays, and the impact of cockpit design on pilot workload. Particular attention is given to possible advanced-technology improvements, such as control stabilization and augmentation, FBW and fly-by-light systems, multifunction displays, night-vision goggles, pilot night-vision systems, night-vision displays with superimposed symbols, target acquisition and designation systems, and aural displays. Diagrams, drawings, and photographs are provided.
A Comparison of the AVS-9 and the Panoramic Night Vision Goggles During Rotorcraft Hover and Landing
NASA Technical Reports Server (NTRS)
Szoboszlay, Zoltan; Haworth, Loran; Simpson, Carol
2000-01-01
A flight test was conducted to assess any differences in pilot-vehicle performance and pilot opinion between the use of a current generation night vision goggle (the AVS-9) and one variant of the prototype panoramic night vision goggle (the PNVGII). The panoramic goggle has more than double the horizontal field-of-view of the AVS-9, but reduced image quality. Overall the panoramic goggles compared well to the AVS-9 goggles. However, pilot comment and data are consistent with the assertion that some of the benefits of additional field-of-view with the panoramic goggles were negated by the reduced image quality of the particular variant of the panoramic goggles tested.
2009-03-01
infrared, thermal , or night vision applications. Understanding the true capabilities and limitations of the ALAN camera and its applicability to a...an option to more expensive infrared, thermal , or night vision applications. Ultimately, it will be clear whether the configuration of the Kestrel...45 A. THERMAL CAMERAS................................................................................45 1
Three spectrally distinct photoreceptors in diurnal and nocturnal Australian ants.
Ogawa, Yuri; Falkowski, Marcin; Narendra, Ajay; Zeil, Jochen; Hemmi, Jan M
2015-06-07
Ants are thought to be special among Hymenopterans in having only dichromatic colour vision based on two spectrally distinct photoreceptors. Many ants are highly visual animals, however, and use vision extensively for navigation. We show here that two congeneric day- and night-active Australian ants have three spectrally distinct photoreceptor types, potentially supporting trichromatic colour vision. Electroretinogram recordings show the presence of three spectral sensitivities with peaks (λmax) at 370, 450 and 550 nm in the night-active Myrmecia vindex and peaks at 370, 470 and 510 nm in the day-active Myrmecia croslandi. Intracellular electrophysiology on individual photoreceptors confirmed that the night-active M. vindex has three spectral sensitivities with peaks (λmax) at 370, 430 and 550 nm. A large number of the intracellular recordings in the night-active M. vindex show unusually broad-band spectral sensitivities, suggesting that photoreceptors may be coupled. Spectral measurements at different temporal frequencies revealed that the ultraviolet receptors are comparatively slow. We discuss the adaptive significance and the probability of trichromacy in Myrmecia ants in the context of dim light vision and visual navigation. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
A Comparison of the AVS-9 and the Panoramic Night Vision Goggle During Rotorcraft Hover and Landing
NASA Technical Reports Server (NTRS)
Szoboszlay, Zoltan; Haworth, Loran; Simpson, Carol; Rutkowski, Michael (Technical Monitor)
2001-01-01
The purpose of this flight test was to measure any differences in pilot-vehicle performance and pilot opinion between the use of the current generation AVS-9 Night Vision Goggle and one variant of the prototype Panoramic Night Vision Goggle (the PNV.GII). The PNVGII has more than double the horizontal field-of-view of the AVS-9, but reduced image quality. The flight path of the AH-1S helicopter was used as a measure of pilot-vehicle performance. Also recorded were subjective measures of flying qualities, physical reserves of the pilot, situational awareness, and display usability. Pilot comment and data indicate that the benefits of additional FOV with the PNVGIIs are to some extent negated by the reduced image quality of the PNVGIIs.
Genotype and phenotype of 101 dutch patients with congenital stationary night blindness.
Bijveld, Mieke M C; Florijn, Ralph J; Bergen, Arthur A B; van den Born, L Ingeborgh; Kamermans, Maarten; Prick, Liesbeth; Riemslag, Frans C C; van Schooneveld, Mary J; Kappers, Astrid M L; van Genderen, Maria M
2013-10-01
To investigate the relative frequency of the genetic causes of the Schubert-Bornschein type of congenital stationary night blindness (CSNB) and to determine the genotype-phenotype correlations in CSNB1 and CSNB2. Clinic-based, longitudinal, multicenter study. A total of 39 patients with CSNB1 from 29 families and 62 patients with CSNB2 from 43 families. Patients underwent full ophthalmologic and electrophysiologic examinations. On the basis of standard electroretinograms (ERGs), patients were diagnosed with CSNB1 or CSNB2. Molecular analysis was performed by direct Sanger sequencing of the entire coding regions in NYX, TRPM1, GRM6, and GPR179 in patients with CSNB1 and CACNA1F and CABP4 in patients with CSNB2. Data included genetic cause of CSNB, refractive error, visual acuity, nystagmus, strabismus, night blindness, photophobia, color vision, dark adaptation (DA) curve, and standard ERGs. A diagnosis of CSNB1 or CSNB2 was based on standard ERGs. The photopic ERG was the most specific criterion to distinguish between CSNB1 and CSNB2 because it showed a "square-wave" appearance in CSNB1 and a decreased b-wave in CSNB2. Mutations causing CSNB1 were found in NYX (20 patients, 13 families), TRPM1 (10 patients, 9 families), GRM6 (4 patients, 3 families), and GPR179 (2 patients, 1 family). Congenital stationary night blindness 2 was primarily caused by mutations in CACNA1F (55 patients, 37 families). Only 3 patients had causative mutations in CABP4 (2 families). Patients with CSNB1 mainly had rod-related problems, and patients with CSNB2 had rod- and cone-related problems. The visual acuity on average was better in CSNB1 (0.30 logarithm of the minimum angle of resolution [logMAR]) than in CSNB2 (0.52 logMAR). All patients with CSNB1 and only 54% of the patients with CSNB2 reported night blindness. The dark-adapted threshold was on average more elevated in CSNB1 (3.0 log) than in CSNB2 (1.8 log). The 3 patients with CABP4 had a relative low visual acuity, were hyperopic, had severe nonspecific color vision defects, and had only 1.0 log elevated DA threshold. Congenital stationary night blindness 1, despite different causative mutations, shows 1 unique CSNB1 phenotype. Congenital stationary night blindness 2 caused by mutations in CABP4 merely shows cone-related problems and therefore appears to be distinct from CSNB2 caused by mutations in CACNA1F. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Stetson, Suzanne; Weber, Hadley; Crosby, Frank J.; Tinsley, Kenneth; Kloess, Edmund; Nevis, Andrew J.; Holloway, John H., Jr.; Witherspoon, Ned H.
2004-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) project has developed and tested a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). The Coastal System Station"s ALRT project, under funding from the Office of Naval Research (ONR), has been designing, developing, integrating, and testing commercial arrays using a Cessna airborne platform over the last several years. This has led to the development of the Airborne Laser Diode Array Illuminator wide field-of-view (ALDAI-W) imaging test bed system. The ALRT project tested ALDAI-W at the Army"s Night Vision Lab"s Airborne Mine Detection Arid Test. By participating in Night Vision"s test, ALRT was able to collect initial prototype nighttime operational data using ALDAI-W, showing impressive results and pioneering the way for final test bed demonstration conducted in September 2003. This paper describes the ALDAI-W Arid Test and results, along with processing steps used to generate imagery.
WILLIAM F. LAUDENSLAYER; ROBERTA J. FARGO
1997-01-01
In 1993 to 1996, dusky-footed woodrats (Neotoma fuscipes) were tracked using night-vision goggles, hght-tags (LED with battery), and fluorescent powder to better understand their microhabitat use. Traclung was conducted in 3 oak woodland study sites in the southern Sierra Nevada, 16 m northeast of Fresno, California. Nightvision goggles were not very useful for direct...
2007-06-28
SUBJECTS 7 DURATION 7 DESCRIPTION OF EXPERIMENT 7 COGNITIVE PERFORMANCE BATTERY 8 WORK LOAD 10 VISUAL...Once During the Experimental Session vi LIST OF...shared performance on several sub tasks under experimenter manipulated workload conditions such as monitoring of dials and displays with dynamic
Visual evoked potentials through night vision goggles.
Rabin, J
1994-04-01
Night vision goggles (NVG's) have widespread use in military and civilian environments. NVG's amplify ambient illumination making performance possible when there is insufficient illumination for normal vision. While visual performance through NVG's is commonly assessed by measuring threshold functions such as visual acuity, few attempts have been made to assess vision through NVG's at suprathreshold levels of stimulation. Such information would be useful to better understand vision through NVG's across a range of stimulus conditions. In this study visual evoked potentials (VEP's) were used to evaluate vision through NVG's across a range of stimulus contrasts. The amplitude and latency of the VEP varied linearly with log contrast. A comparison of VEP's recorded with and without NVG's was used to estimate contrast attenuation through the device. VEP's offer an objective, electrophysiological tool to assess visual performance through NVG's at both threshold and suprathreshold levels of visual stimulation.
Bamashmus, Mahfouth A; Hubaish, Khammash; Alawad, Mohammed; Alakhlee, Hisham
2015-01-01
The purpose was to evaluate subjective quality of vision and patient satisfaction after laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism. A self-administered patient questionnaire consisting 29 items was prospectively administered to LASIK patients at the Yemen Magrabi Hospital. Seven scales covering specific aspects of the quality of vision were formulated including; global satisfaction; quality of uncorrected and corrected vision; quality of night vision; glare; daytime driving and; night driving. Main outcome measures were responses to individual questions and scale scores and correlations with clinical parameters. The scoring scale ranged from 1 (dissatisfied) to 3 (very satisfied) and was stratified in the following manner: 1-1.65 = dissatisfied; 1.66-2.33 = satisfied and; 2.33-3 = very satisfied. Data at 6 months postoperatively are reported. This study sample was comprised of 200 patients (122 females: 78 males) ranging in age from 18 to 46 years old. The preoperative myopic sphere was - 3.50 ± 1.70 D and myopic astigmatism was 0.90 ± 0.82 D. There were 96% of eyes within ± 1.00 D of the targeted correction. Postoperatively, the uncorrected visual acuity was 20/40 or better in 99% of eyes. The mean score for the overall satisfaction was 2.64 ± 0.8. A total of 98.5% of patients was satisfied or very satisfied with their surgery, 98.5% considered their main goal for surgery was achieved. Satisfaction with uncorrected vision was 2.5 ± 0.50. The main score for glare was 1.98 ± 0.7 at night. Night driving was rated more difficult preoperatively by 6.2%, whereas 79% had less difficulty driving at night. Patient satisfaction with uncorrected vision after LASIK for myopia and myopic astigmatism appears to be excellent and is related to the residual refractive error postoperatively.
Bamashmus, Mahfouth A.; Hubaish, Khammash; Alawad, Mohammed; Alakhlee, Hisham
2015-01-01
Purpose: The purpose was to evaluate subjective quality of vision and patient satisfaction after laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism. Patients and Methods: A self-administered patient questionnaire consisting 29 items was prospectively administered to LASIK patients at the Yemen Magrabi Hospital. Seven scales covering specific aspects of the quality of vision were formulated including; global satisfaction; quality of uncorrected and corrected vision; quality of night vision; glare; daytime driving and; night driving. Main outcome measures were responses to individual questions and scale scores and correlations with clinical parameters. The scoring scale ranged from 1 (dissatisfied) to 3 (very satisfied) and was stratified in the following manner: 1-1.65 = dissatisfied; 1.66-2.33 = satisfied and; 2.33-3 = very satisfied. Data at 6 months postoperatively are reported. Results: This study sample was comprised of 200 patients (122 females: 78 males) ranging in age from 18 to 46 years old. The preoperative myopic sphere was − 3.50 ± 1.70 D and myopic astigmatism was 0.90 ± 0.82 D. There were 96% of eyes within ± 1.00 D of the targeted correction. Postoperatively, the uncorrected visual acuity was 20/40 or better in 99% of eyes. The mean score for the overall satisfaction was 2.64 ± 0.8. A total of 98.5% of patients was satisfied or very satisfied with their surgery, 98.5% considered their main goal for surgery was achieved. Satisfaction with uncorrected vision was 2.5 ± 0.50. The main score for glare was 1.98 ± 0.7 at night. Night driving was rated more difficult preoperatively by 6.2%, whereas 79% had less difficulty driving at night. Conclusion: Patient satisfaction with uncorrected vision after LASIK for myopia and myopic astigmatism appears to be excellent and is related to the residual refractive error postoperatively. PMID:25624684
2013-11-01
Acoustic Measurement and Model Predictions for the Aural Nondetectability of Two Night-Vision Goggles by Jeremy Gaston, Tim Mermagen, and...Goggles Jeremy Gaston, Tim Mermagen, and Kelly Dickerson Human Research and Engineering Directorate, ARL...5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Jeremy Gaston, Tim Mermagen, and Kelly Dickerson 5d. PROJECT NUMBER 74A 5e. TASK NUMBER 5f. WORK
Stem Cell Ophthalmology Treatment Study II
2018-02-01
Retinal Disease; Age-Related Macular Degeneration; Retinitis Pigmentosa; Stargardt Disease; Optic Neuropathy; Nonarteritic Ischemic Optic Neuropathy; Optic Atrophy; Optic Nerve Disease; Glaucoma; Leber Hereditary Optic Neuropathy; Blindness; Vision Loss Night; Vision Loss Partial; Vision, Low; Retinopathy; Maculopathy; Macular Degeneration; Retina Atrophy
The Effects of Modafinil and OTC Stimulants on Physical and Cognitive Performance
2016-03-07
least 7 hours per night were either rescheduled until the sleep requirements were met or dropped from the study. 2.1.3 Vision testing. Vision...the study. Those potential participants who did not sleep at least 7 hours per night were either rescheduled until the sleep requirements were met...could not reschedule another time to return. Therefore, 19 individuals completed the study. One participant’s data indicated poor compliance with
Effects of Extended Hypoxia on Night Vision
1983-06-01
Continue on reverse aide it necessary and identify by block number) hypoxia, anoxia , night vision, dark adaptation, extended hypoxia /y虦 SABDST’RACT M=t...and his colleagues, who not only quantified significant aspects of the dark adaptation function due to anoxia (hypoxia) (12,13,14,16), but also...and his co-workers (7) conducted related and very significant research on bright- ness discrimination, and concluded that anoxia acts mainly on the
Development of Air Force aerial spray night operations: High altitude swath characterization
USDA-ARS?s Scientific Manuscript database
Multiple trials were conducted from 2006 to 2014 in an attempt to validate aerial spray efficacy at altitudes conducive to night spray operations using night vision goggles (NVG). Higher altitude application of pesticide (>400 feet above ground level [AGL]) suggested that effective vector control mi...
Night vision imaging systems design, integration, and verification in military fighter aircraft
NASA Astrophysics Data System (ADS)
Sabatini, Roberto; Richardson, Mark A.; Cantiello, Maurizio; Toscano, Mario; Fiorini, Pietro; Jia, Huamin; Zammit-Mangion, David
2012-04-01
This paper describes the developmental and testing activities conducted by the Italian Air Force Official Test Centre (RSV) in collaboration with Alenia Aerospace, Litton Precision Products and Cranfiled University, in order to confer the Night Vision Imaging Systems (NVIS) capability to the Italian TORNADO IDS (Interdiction and Strike) and ECR (Electronic Combat and Reconnaissance) aircraft. The activities consisted of various Design, Development, Test and Evaluation (DDT&E) activities, including Night Vision Goggles (NVG) integration, cockpit instruments and external lighting modifications, as well as various ground test sessions and a total of eighteen flight test sorties. RSV and Litton Precision Products were responsible of coordinating and conducting the installation activities of the internal and external lights. Particularly, an iterative process was established, allowing an in-site rapid correction of the major deficiencies encountered during the ground and flight test sessions. Both single-ship (day/night) and formation (night) flights were performed, shared between the Test Crews involved in the activities, allowing for a redundant examination of the various test items by all participants. An innovative test matrix was developed and implemented by RSV for assessing the operational suitability and effectiveness of the various modifications implemented. Also important was definition of test criteria for Pilot and Weapon Systems Officer (WSO) workload assessment during the accomplishment of various operational tasks during NVG missions. Furthermore, the specific technical and operational elements required for evaluating the modified helmets were identified, allowing an exhaustive comparative evaluation of the two proposed solutions (i.e., HGU-55P and HGU-55G modified helmets). The results of the activities were very satisfactory. The initial compatibility problems encountered were progressively mitigated by incorporating modifications both in the front and rear cockpits at the various stages of the test campaign. This process allowed a considerable enhancement of the TORNADO NVIS configuration, giving a good medium-high level NVG operational capability to the aircraft. Further developments also include the design, integration and test of internal/external lighting for the Italian TORNADO "Mid Life Update" (MLU) and other programs, such as the AM-X aircraft internal/external lights modification/testing and the activities addressing low-altitude NVG operations with fast jets (e.g., TORNADO, AM-X, MB-339CD), a major issue being the safe ejection of aircrew with NVG and NVG modified helmets. Two options have been identified for solving this problem: namely the modification of the current Gentex HGU-55 helmets and the design of a new helmet incorporating a reliable NVG connection/disconnection device (i.e., a mechanical system fully integrated in the helmet frame), with embedded automatic disconnection capability in case of ejection.
1984-08-01
inside or outside o•h United States without first obtaining me esport license. A violation of the ITAR or CAR m4ay be ublect to a penalty of up to to...clinical data are shown in Table 2. The subjects ranged in age from 24 to 61; there were 7 males and 3 females ; 6 of the subjects wore a visual
2009-07-01
AN/ PAQ -4C and AN-PEQ-2A) which were used in conjunction with night vision goggles (NVGs, AN/PVS-7B), the thermal weapon sight (TWS, AN/PAS-13), and...lights (AN/ PAQ -4C and AN-PEQ-2A) which were used in conjunction with night vision goggles (NVGs, AN/PVS-7B), and the thermal weapon sight (TWS, AN/PAS
The Hunter-Killer Model, Version 2.0. User’s Manual.
1986-12-01
Contract No. DAAK21-85-C-0058 Prepared for The Center for Night Vision and Electro - Optics DELNV-V Fort Belvoir, Virginia 22060 This document has been...INQUIRIES Inquiries concerning the Hunter-Killer Model or the Hunter-Killer Database System should be addressed to: 1-1 I The Night Vision and Electro - Optics Center...is designed and constructed to study the performance of electro - optic sensor systems in a combat scenario. The model simulates a two-sided battle
A Unified Taxonomic Approach to the Laboratory Assessment of Visionic Devices
2006-09-01
the ratification stage with member nations. Marasco and Task 4 presented a large array of tests applicable to image intensification-based visionic...aircraft.” In print. 4. Marasco , P. L., and Task, H. L. 1999. “Optical characterization of wide field-of-view night vision devices,” in
77 FR 5423 - Airworthiness Directives; Bell Helicopter Textron Canada, Limited (Bell) Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-03
... over- temperature warning light by installing a filter to prevent degradation of the pilot's vision...-temperature warning light is installed, this AD would require installing an NVIS filter. The proposed actions... a filter to prevent degradation of the pilot's vision while using night vision goggles and to...
Parkhurst, Gregory D
2016-01-01
Purpose The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS) in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK). Patients and methods This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL) and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles. Results Preoperative mean spherical equivalent was −6.10 D in the ICL group and −6.04 D in the LASIK group (P=0.863). Three months postoperatively, super vision acuity (SVa), super vision acuity with (low-luminance) goggles (SVaG), super vision contrast (SVc), and super vision contrast with (low luminance) goggles (SVcG) significantly improved in the ICL and LASIK groups (P<0.001). Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =−0.134, LASIK =−0.085; P=0.032). Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024). Mean improvement in SVa at 3 months was comparable in both groups (P=0.154). Conclusion Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction. PMID:27418804
Parkhurst, Gregory D
2016-01-01
The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS) in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK). This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL) and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles. Preoperative mean spherical equivalent was -6.10 D in the ICL group and -6.04 D in the LASIK group (P=0.863). Three months postoperatively, super vision acuity (SVa), super vision acuity with (low-luminance) goggles (SVaG), super vision contrast (SVc), and super vision contrast with (low luminance) goggles (SVcG) significantly improved in the ICL and LASIK groups (P<0.001). Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =-0.134, LASIK =-0.085; P=0.032). Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024). Mean improvement in SVa at 3 months was comparable in both groups (P=0.154). Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction.
A Most Rare Vision: Improvisations on "A Midsummer Night's Dream."
ERIC Educational Resources Information Center
Hakaim, Charles J., Jr.
1993-01-01
Describes one teacher's methods for introducing to secondary English students the concepts of improvisation, experimentation, and innovation. Discusses numerous techniques for fostering such skills when working with William Shakespeare's "A Midsummer Night's Dream." (HB)
Mold, James W; Roberts, Michelle; Aboshady, Hesham M
2004-01-01
We wanted to estimate the prevalence of night sweats, day sweats, and hot flashes in older primary care patients and identify associated factors. We undertook a cross-sectional study of patients older than 64 years recruited from the practices of 23 family physicians. Variables included sociodemographic information, health habits, chronic medical problems, symptoms, quality of life, and the degree to which patients were bothered by night sweats, daytime sweating, and hot flashes. Among the 795 patients, 10% reported being bothered by night sweats, 9% by day sweats, and 8% by hot flashes. Eighteen percent reported at least 1 of these symptoms. The 3 symptoms were strongly correlated. Factors associated with night sweats in the multivariate models were age (odds ratio [OR] 0.94/y; 95% confidence interval [CI], 0.89-0.98), fever (OR 12.60; 95% CI, 6.58-24.14), muscle cramps (OR 2.84; 95% CI, 1.53-5.24), numbness of hands and feet (OR 3.34; 95% CI, 1.92-5.81), impaired vision (OR 2.45; 95% CI, 1.41-4.27), and hearing loss (OR 1.84; 95% CI, 1.03-3.27). Day sweats were associated with fever (OR 4.10; 95% CI, 2.14-7.87), restless legs (OR 3.22; 95% CI, 1.76-5.89), lightheadedness (OR 2.24; 95% CI, 1.30-3.88), and diabetes (OR 2.19; 95% CI, 1.22-3.92). Hot flashes were associated with nonwhite race (OR 3.10; 95% CI, 1.60-5.98), fever (OR 3.98; 95% CI, 1.97-8.04), bone pain (OR 2.31; CI 95%: 1.30-4.08), impaired vision (OR 2.12; 95% CI, 1.19-3.79), and nervous spells (OR 1.87; 95% CI, 1.01-3.46). All 3 symptoms were associated with reduced quality of life. Many older patients are bothered by night sweats, day sweats, and hot flashes. Though these symptoms are similar and related, they have somewhat different associations with other variables. Clinical evaluation should include questions about febrile illnesses, sensory deficits, anxiety, depression, pain, muscle cramps, and restless legs syndrome.
Colour blindness in everyday life and car driving.
Tagarelli, Antonio; Piro, Anna; Tagarelli, Giuseppe; Lantieri, Pasquale Bruno; Risso, Domenico; Olivieri, Rosario Luciano
2004-08-01
The aim of the present work was to ascertain, through the administration of a psychosocial questionnaire, the difficulties that subjects with defective colour vision experience in carrying out everyday tasks and work, including driving a car with a driver's licence held for no more than 3 years. Subjects with defective colour vision (n = 151) and subjects with normal vision (n = 302) completed a psychosocial questionnaire regarding the difficulties associated with congenital colour vision deficiency in daily life, work and driving a car. Subjects were diagnosed as colour-blind using the Ishihara test. Statistically significant differences between the two samples were found for daily life activities. Subjects with defective colour vision preferred daytime driving. At night, subjects with defective colour vision had difficulty identifying reflectors on the road and the rear signal lights of cars ahead of them. Colour-blind Calabrian subjects admitted to experiencing colour-related difficulties with a wide range of occupational tasks and leisure pursuits. In particular, colour-blind Calabrian subjects preferred daytime driving, and fewer drove regularly, compared to orthochromatics, who were indifferent to night or daytime driving.
Ultraviolet vision may be widespread in bats
Gorresen, P. Marcos; Cryan, Paul; Dalton, David C.; Wolf, Sandy; Bonaccorso, Frank
2015-01-01
Insectivorous bats are well known for their abilities to find and pursue flying insect prey at close range using echolocation, but they also rely heavily on vision. For example, at night bats use vision to orient across landscapes, avoid large obstacles, and locate roosts. Although lacking sharp visual acuity, the eyes of bats evolved to function at very low levels of illumination. Recent evidence based on genetics, immunohistochemistry, and laboratory behavioral trials indicated that many bats can see ultraviolet light (UV), at least at illumination levels similar to or brighter than those before twilight. Despite this growing evidence for potentially widespread UV vision in bats, the prevalence of UV vision among bats remains unknown and has not been studied outside of the laboratory. We used a Y-maze to test whether wild-caught bats could see reflected UV light and whether such UV vision functions at the dim lighting conditions typically experienced by night-flying bats. Seven insectivorous species of bats, representing five genera and three families, showed a statistically significant ‘escape-toward-the-light’ behavior when placed in the Y-maze. Our results provide compelling evidence of widespread dim-light UV vision in bats.
A Summary of Proceedings for the Advanced Deployable Day/Night Simulation Symposium
2009-07-01
initiated to design , develop, and deliver transportable visual simulations that jointly provide night-vision and high-resolution daylight capability. The...Deployable Day/Night Simulation (ADDNS) Technology Demonstration Project was initiated to design , develop, and deliver transportable visual...was Dr. Richard Wildes (York University); Mr. Vitaly Zholudev (Department of Computer Science, York University), Mr. X. Zhu (Neptec Design Group), and
Sensor fusion to enable next generation low cost Night Vision systems
NASA Astrophysics Data System (ADS)
Schweiger, R.; Franz, S.; Löhlein, O.; Ritter, W.; Källhammer, J.-E.; Franks, J.; Krekels, T.
2010-04-01
The next generation of automotive Night Vision Enhancement systems offers automatic pedestrian recognition with a performance beyond current Night Vision systems at a lower cost. This will allow high market penetration, covering the luxury as well as compact car segments. Improved performance can be achieved by fusing a Far Infrared (FIR) sensor with a Near Infrared (NIR) sensor. However, fusing with today's FIR systems will be too costly to get a high market penetration. The main cost drivers of the FIR system are its resolution and its sensitivity. Sensor cost is largely determined by sensor die size. Fewer and smaller pixels will reduce die size but also resolution and sensitivity. Sensitivity limits are mainly determined by inclement weather performance. Sensitivity requirements should be matched to the possibilities of low cost FIR optics, especially implications of molding of highly complex optical surfaces. As a FIR sensor specified for fusion can have lower resolution as well as lower sensitivity, fusing FIR and NIR can solve performance and cost problems. To allow compensation of FIR-sensor degradation on the pedestrian detection capabilities, a fusion approach called MultiSensorBoosting is presented that produces a classifier holding highly discriminative sub-pixel features from both sensors at once. The algorithm is applied on data with different resolution and on data obtained from cameras with varying optics to incorporate various sensor sensitivities. As it is not feasible to record representative data with all different sensor configurations, transformation routines on existing high resolution data recorded with high sensitivity cameras are investigated in order to determine the effects of lower resolution and lower sensitivity to the overall detection performance. This paper also gives an overview of the first results showing that a reduction of FIR sensor resolution can be compensated using fusion techniques and a reduction of sensitivity can be compensated.
Rotary-wing flight test methods used for the evaluation of night vision devices
NASA Astrophysics Data System (ADS)
Haworth, Loran A.; Blanken, Christopher J.; Szoboszlay, Zoltan P.
2001-08-01
The U.S. Army Aviation mission includes flying helicopters at low altitude, at night, and in adverse weather. Night Vision Devices (NVDs) are used to supplement the pilot's visual cues for night flying. As the military requirement to conduct night helicopter operations has increased, the impact of helicopter flight operations with NVD technology in the Degraded Visual Environment (DVE) became increasingly important to quantify. Aeronautical Design Standard-33 (ADS- 33) was introduced to update rotorcraft handling qualities requirements and to quantify the impact of the NVDs in the DVE. As reported in this paper, flight test methodology in ADS-33 has been used by the handling qualities community to measure the impact of NVDs on task performance in the DVE. This paper provides the background and rationale behind the development of ADS-33 flight test methodology for handling qualities in the DVE, as well as the test methodology developed for human factor assessment of NVDs in the DVE. Lessons learned, shortcomings and recommendations for NVD flight test methodology are provided in this paper.
NASA Astrophysics Data System (ADS)
Upadhyaya, A. S.; Bandyopadhyay, P. K.
2012-11-01
In state of art technology, integrated devices are widely used or their potential advantages. Common system reduces weight as well as total space covered by its various parts. In the state of art surveillance system integrated SWIR and night vision system used for more accurate identification of object. In this system a common optical window is used, which passes the radiation of both the regions, further both the spectral regions are separated in two channels. ZnS is a good choice for a common window, as it transmit both the region of interest, night vision (650 - 850 nm) as well as SWIR (0.9 - 1.7 μm). In this work a broad band anti reflection coating is developed on ZnS window to enhance the transmission. This seven layer coating is designed using flip flop design method. After getting the final design, some minor refinement is done, using simplex method. SiO2 and TiO2 coating material combination is used for this work. The coating is fabricated by physical vapour deposition process and the materials were evaporated by electron beam gun. Average transmission of both side coated substrate from 660 to 1700 nm is 95%. This coating also acts as contrast enhancement filter for night vision devices, as it reflect the region of 590 - 660 nm. Several trials have been conducted to check the coating repeatability, and it is observed that transmission variation in different trials is not very much and it is under the tolerance limit. The coating also passes environmental test for stability.
Salient contour extraction from complex natural scene in night vision image
NASA Astrophysics Data System (ADS)
Han, Jing; Yue, Jiang; Zhang, Yi; Bai, Lian-fa
2014-03-01
The theory of center-surround interaction in non-classical receptive field can be applied in night vision information processing. In this work, an optimized compound receptive field modulation method is proposed to extract salient contour from complex natural scene in low-light-level (LLL) and infrared images. The kernel idea is that multi-feature analysis can recognize the inhomogeneity in modulatory coverage more accurately and that center and surround with the grouping structure satisfying Gestalt rule deserves high connection-probability. Computationally, a multi-feature contrast weighted inhibition model is presented to suppress background and lower mutual inhibition among contour elements; a fuzzy connection facilitation model is proposed to achieve the enhancement of contour response, the connection of discontinuous contour and the further elimination of randomly distributed noise and texture; a multi-scale iterative attention method is designed to accomplish dynamic modulation process and extract contours of targets in multi-size. This work provides a series of biologically motivated computational visual models with high-performance for contour detection from cluttered scene in night vision images.
Wu, Yonghua; Hadly, Elizabeth A; Teng, Wenjia; Hao, Yuyang; Liang, Wei; Liu, Yu; Wang, Haitao
2016-09-20
Owls (Strigiformes) represent a fascinating group of birds that are the ecological night-time counterparts to diurnal raptors (Accipitriformes). The nocturnality of owls, unusual within birds, has favored an exceptional visual system that is highly tuned for hunting at night, yet the molecular basis for this adaptation is lacking. Here, using a comparative evolutionary analysis of 120 vision genes obtained by retinal transcriptome sequencing, we found strong positive selection for low-light vision genes in owls, which contributes to their remarkable nocturnal vision. Not surprisingly, we detected gene loss of the violet/ultraviolet-sensitive opsin (SWS1) in all owls we studied, but two other color vision genes, the red-sensitive LWS and the blue-sensitive SWS2, were found to be under strong positive selection, which may be linked to the spectral tunings of these genes toward maximizing photon absorption in crepuscular conditions. We also detected the only other positively selected genes associated with motion detection in falcons and positively selected genes associated with bright-light vision and eye protection in other diurnal raptors (Accipitriformes). Our results suggest the adaptive evolution of vision genes reflect differentiated activity time and distinct hunting behaviors.
Wu, Yonghua; Hadly, Elizabeth A.; Teng, Wenjia; Hao, Yuyang; Liang, Wei; Liu, Yu; Wang, Haitao
2016-01-01
Owls (Strigiformes) represent a fascinating group of birds that are the ecological night-time counterparts to diurnal raptors (Accipitriformes). The nocturnality of owls, unusual within birds, has favored an exceptional visual system that is highly tuned for hunting at night, yet the molecular basis for this adaptation is lacking. Here, using a comparative evolutionary analysis of 120 vision genes obtained by retinal transcriptome sequencing, we found strong positive selection for low-light vision genes in owls, which contributes to their remarkable nocturnal vision. Not surprisingly, we detected gene loss of the violet/ultraviolet-sensitive opsin (SWS1) in all owls we studied, but two other color vision genes, the red-sensitive LWS and the blue-sensitive SWS2, were found to be under strong positive selection, which may be linked to the spectral tunings of these genes toward maximizing photon absorption in crepuscular conditions. We also detected the only other positively selected genes associated with motion detection in falcons and positively selected genes associated with bright-light vision and eye protection in other diurnal raptors (Accipitriformes). Our results suggest the adaptive evolution of vision genes reflect differentiated activity time and distinct hunting behaviors. PMID:27645106
Complete Vision-Based Traffic Sign Recognition Supported by an I2V Communication System
García-Garrido, Miguel A.; Ocaña, Manuel; Llorca, David F.; Arroyo, Estefanía; Pozuelo, Jorge; Gavilán, Miguel
2012-01-01
This paper presents a complete traffic sign recognition system based on vision sensor onboard a moving vehicle which detects and recognizes up to one hundred of the most important road signs, including circular and triangular signs. A restricted Hough transform is used as detection method from the information extracted in contour images, while the proposed recognition system is based on Support Vector Machines (SVM). A novel solution to the problem of discarding detected signs that do not pertain to the host road is proposed. For that purpose infrastructure-to-vehicle (I2V) communication and a stereo vision sensor are used. Furthermore, the outputs provided by the vision sensor and the data supplied by the CAN Bus and a GPS sensor are combined to obtain the global position of the detected traffic signs, which is used to identify a traffic sign in the I2V communication. This paper presents plenty of tests in real driving conditions, both day and night, in which an average detection rate over 95% and an average recognition rate around 93% were obtained with an average runtime of 35 ms that allows real-time performance. PMID:22438704
Complete vision-based traffic sign recognition supported by an I2V communication system.
García-Garrido, Miguel A; Ocaña, Manuel; Llorca, David F; Arroyo, Estefanía; Pozuelo, Jorge; Gavilán, Miguel
2012-01-01
This paper presents a complete traffic sign recognition system based on vision sensor onboard a moving vehicle which detects and recognizes up to one hundred of the most important road signs, including circular and triangular signs. A restricted Hough transform is used as detection method from the information extracted in contour images, while the proposed recognition system is based on Support Vector Machines (SVM). A novel solution to the problem of discarding detected signs that do not pertain to the host road is proposed. For that purpose infrastructure-to-vehicle (I2V) communication and a stereo vision sensor are used. Furthermore, the outputs provided by the vision sensor and the data supplied by the CAN Bus and a GPS sensor are combined to obtain the global position of the detected traffic signs, which is used to identify a traffic sign in the I2V communication. This paper presents plenty of tests in real driving conditions, both day and night, in which an average detection rate over 95% and an average recognition rate around 93% were obtained with an average runtime of 35 ms that allows real-time performance.
Tchah, Hungwon; Nam, Kiyeun; Yoo, Aeri
2017-01-01
AIM To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberrations, preferred reading distances, preoperative and postoperative refractive errors, mesopic and photopic pupil diameters, and the mesopic and photopic kappa angles were assessed. Patients were also administered a satisfaction survey. Photic phenomena were graded by questionnaire. Independent-related factors were identified by correlation and bivariate logistic regression analyses. RESULTS The distance from the photopic to the mesopic pupil center (pupil center shift) was significantly associated with glare/halo symptoms [odds ratio (OR)=2.065, 95% confidence interval (CI)=0.916-4.679, P=0.006] and night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007). The preoperative photopic angle kappa was significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041). The photopic angle kappa was also significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041) and with night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007) in patients implanted with rotationally asymmetric MIOLs. CONCLUSION A large pupil center shift and misalignment between the visual and pupillary axis (angle kappa) may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs. PMID:28251083
An Analysis of Helicopter Pilot Scan Techniques While Flying at Low Altitudes and High Speed
2012-09-01
Manager SV Synthetic Vision TFH Total Flight Hours TOFT Tactical Operational Flight Trainer VFR Visual Flight Rules VMC Visual Meteorological...Crognale, 2008). Recently, the use of synthetic vision (SV) and a heads-up- display (HUD) have been a topic of discussion in the aviation community... Synthetic vision uses external cameras to provide the pilot with an enhanced view of the outside world, usually with the assistance of night vision
Civil use of night vision goggles within the National Airspace System
NASA Astrophysics Data System (ADS)
Winkel, James G.; Faber, Lorelei
2001-08-01
When properly employed, Night Vision Goggles (NVGs) improve a pilot's ability to see during periods of darkness. The resultant enhancement in situational awareness achieved when using NVGs, increases light safety during night VFR operations. FAA is constrained with a lack of requisite regulatory and guidance infrastructure to adequately facilitate the civil request for use in NVGs within the National Airspace System (NAS) Appliances and Equipment, is formed and tasked to develop: operational concept and operational requirements for NVG implementation into the NAS, minimum operational performance standards for NVGs, and training guidelines and considerations for NVG operations. This paper provides a historical perspective on use of NVGs within the NAS, the status of SC-196 work in progress, FAA integration of SC-196 committee products and the harmonization effort between EUROCAEs NVG committee and SC- 196.
Multi-channel automotive night vision system
NASA Astrophysics Data System (ADS)
Lu, Gang; Wang, Li-jun; Zhang, Yi
2013-09-01
A four-channel automotive night vision system is designed and developed .It is consist of the four active near-infrared cameras and an Mulit-channel image processing display unit,cameras were placed in the automobile front, left, right and rear of the system .The system uses near-infrared laser light source,the laser light beam is collimated, the light source contains a thermoelectric cooler (TEC),It can be synchronized with the camera focusing, also has an automatic light intensity adjustment, and thus can ensure the image quality. The principle of composition of the system is description in detail,on this basis, beam collimation,the LD driving and LD temperature control of near-infrared laser light source,four-channel image processing display are discussed.The system can be used in driver assistance, car BLIS, car parking assist system and car alarm system in day and night.
Color defective vision and day and night recognition of aviation color signal light flashes.
DOT National Transportation Integrated Search
1971-07-01
A previous study reported on the efficiency with which various tests of color defective vision can predict performance during daylight conditions on a practical test of ability to discriminate aviation signal red, white, and green. In the current stu...
Vision-based aircraft guidance
NASA Technical Reports Server (NTRS)
Menon, P. K.
1993-01-01
Early research on the development of machine vision algorithms to serve as pilot aids in aircraft flight operations is discussed. The research is useful for synthesizing new cockpit instrumentation that can enhance flight safety and efficiency. With the present work as the basis, future research will produce low-cost instrument by integrating a conventional TV camera together with off-the=shelf digitizing hardware for flight test verification. Initial focus of the research will be on developing pilot aids for clear-night operations. Latter part of the research will examine synthetic vision issues for poor visibility flight operations. Both research efforts will contribute towards the high-speed civil transport aircraft program. It is anticipated that the research reported here will also produce pilot aids for conducting helicopter flight operations during emergency search and rescue. The primary emphasis of the present research effort is on near-term, flight demonstrable technologies. This report discusses pilot aids for night landing and takeoff and synthetic vision as an aid to low visibility landing.
Global Warming: A Reduced Threat?.
NASA Astrophysics Data System (ADS)
Michaels, Patrick J.; Stooksbury, David E.
1992-10-01
One popular and apocalyptic vision of the world influenced by increasing concentrations of infrared-absorbing trace gases is that of ecological disaster brought about by rapidly rising temperatures, sea level, and evaporation rates. This vision developed from a suite of climate models that have since considerably changed in both their dynamics and their estimates of prospective warming. Observed temperatures indicate that much more warming should already have taken place than predicted by earlier models in the Northern Hemisphere, and that night, rather than day, readings in that hemisphere show a relative warming. A high-latitude polar-night warming or a general night warming could be either benign or beneficial. A large number of plant species show both increased growth and greater water-use efficiency under enhanced carbon dioxide.An extensive body of evidence now indicates that anthropo-generated sulfate emissions are mitigating some of the warming, and that increased cloudiness as a result of these emissions will further enhance night, rather than day, warming. The sulfate emissions, though, are not sufficient to explain all of the night warming. However, the sensitivity of climate to anthropogenerated aerosols, and the general lack of previously predicted warming, could drastically alter the debate on global warming in favor of less expensive policies.
DOT National Transportation Integrated Search
2005-12-01
This volume provides an overview of the six studies that compose Phase II of the Enhanced Night Visibility project and the experimental plan for its third and final portion, Phase III. The Phase II studies evaluated up to 12 vision enhancement system...
Night vision goggle stimulation using LCoS and DLP projection technology, which is better?
NASA Astrophysics Data System (ADS)
Ali, Masoud H.; Lyon, Paul; De Meerleer, Peter
2014-06-01
High fidelity night-vision training has become important for many of the simulation systems being procured today. The end-users of these simulation-training systems prefer using their actual night-vision goggle (NVG) headsets. This requires that the visual display system stimulate the NVGs in a realistic way. Historically NVG stimulation was done with cathode-ray tube (CRT) projectors. However, this technology became obsolete and in recent years training simulators do NVG stimulation with laser, LCoS and DLP projectors. The LCoS and DLP projection technologies have emerged as the preferred approach for the stimulation of NVGs. Both LCoS and DLP technologies have advantages and disadvantages for stimulating NVGs. LCoS projectors can have more than 5-10 times the contrast capability of DLP projectors. The larger the difference between the projected black level and the brightest object in a scene, the better the NVG stimulation effects can be. This is an advantage of LCoS technology, especially when the proper NVG wavelengths are used. Single-chip DLP projectors, even though they have much reduced contrast compared to LCoS projectors, can use LED illuminators in a sequential red-green-blue fashion to create a projected image. It is straightforward to add an extra infrared (NVG wavelength) LED into this sequential chain of LED illumination. The content of this NVG channel can be independent of the visible scene, which allows effects to be added that can compensate for the lack of contrast inherent in a DLP device. This paper will expand on the differences between LCoS and DLP projectors for stimulating NVGs and summarize the benefits of both in night-vision simulation training systems.
Marksmanship Requirements from the Perspective of Combat Veterans - Volume 2: Summary Report
2016-02-01
M. McInroy who provided input to the questionnaire and insured that the Army’s Centers of Excellence were aware of the importance of their students ...combat gear Qualify with weapon in combat gear Hit targets at night using aiming lights & night vision goggles Hit targets at night with thermal ...conditions, the junior and some of the senior enlisted were not comfortable under these conditions making it unsatisfactory. 10 Engineer. Different
Color Vision in Color Display Night Vision Goggles.
Liggins, Eric P; Serle, William P
2017-05-01
Aircrew viewing eyepiece-injected symbology on color display night vision goggles (CDNVGs) are performing a visual task involving color under highly unnatural viewing conditions. Their performance in discriminating different colors and responding to color cues is unknown. Experimental laboratory measurements of 1) color discrimination and 2) visual search performance are reported under adaptation conditions representative of a CDNVG. Color discrimination was measured using a two-alternative forced choice (2AFC) paradigm that probes color space uniformly around a white point. Search times in the presence of different degrees of clutter (distractors in the scene) are measured for different potential symbology colors. The discrimination data support previous data suggesting that discrimination is best for colors close to the adapting point in color space (P43 phosphor in this case). There were highly significant effects of background adaptation (white or green) and test color. The search time data show that saturated colors with the greatest chromatic contrast with respect to the background lead to the shortest search times, associated with the greatest saliency. Search times for the green background were around 150 ms longer than for the white. Desaturated colors, along with those close to a typical CDNVG display phosphor in color space, should be avoided by CDNVG designers if the greatest conspicuity of symbology is desired. The results can be used by CDNVG symbology designers to optimize aircrew performance subject to wider constraints arising from the way color is used in the existing conventional cockpit instruments and displays.Liggins EP, Serle WP. Color vision in color display night vision goggles. Aerosp Med Hum Perform. 2017; 88(5):448-456.
Effects of age and illumination on night driving: a road test.
Owens, D Alfred; Wood, Joanne M; Owens, Justin M
2007-12-01
This study investigated the effects of drivers' age and low light on speed, lane keeping, and visual recognition of typical roadway stimuli. Poor visibility, which is exacerbated by age-related changes in vision, is a leading contributor to fatal nighttime crashes. There is little evidence, however, concerning the extent to which drivers recognize and compensate for their visual limitations at night. Young, middle-aged, and elder participants drove on a closed road course in day and night conditions at a "comfortable" speed without speedometer information. During night tests, headlight intensity was varied over a range of 1.5 log units using neutral density filters. Average speed and recognition of road signs decreased significantly as functions of increased age and reduced illumination. Recognition of pedestrians at night was significantly enhanced by retroreflective markings of limb joints as compared with markings of the torso, and this benefit was greater for middle-aged and elder drivers. Lane keeping showed nonlinear effects of lighting, which interacted with task conditions and drivers' lateral bias, indicating that older drivers drove more cautiously in low light. Consistent with the hypothesis that drivers misjudge their visual abilities at night, participants of all age groups failed to compensate fully for diminished visual recognition abilities in low light, although older drivers behaved more cautiously than the younger groups. These findings highlight the importance of educating all road users about the limitations of night vision and provide new evidence that retroreflective markings of the limbs can be of great benefit to pedestrians' safety at night.
Conquest of darkness by management of the stars
NASA Astrophysics Data System (ADS)
Wiseman, Robert S.
This text was presented as the Thomas B. Dowd Memorial Lecture for 1991 national Infrared Information Symposium (IRIS). The history of Army Night Vision from World War II to 1972 proves how the right organization with talented people and proper support can succeed. This presentation not only illustrates the growth of image intensifier technology and families of equipment, but the key events and stars that made it all happen. Described are the management techniques used and how to organize for effective research, development, engineering, and production programs; the evolution of the Far Infrared Common Module program is described; and how the Night Vision Laboratory was unique.
Visual summation in night-flying sweat bees: a theoretical study.
Theobald, Jamie Carroll; Greiner, Birgit; Wcislo, William T; Warrant, Eric J
2006-07-01
Bees are predominantly diurnal; only a few groups fly at night. An evolutionary limitation that bees must overcome to inhabit dim environments is their eye type: bees possess apposition compound eyes, which are poorly suited to vision in dim light. Here, we theoretically examine how nocturnal bees Megalopta genalis fly at light levels usually reserved for insects bearing more sensitive superposition eyes. We find that neural summation should greatly increase M. genalis's visual reliability. Predicted spatial summation closely matches the morphology of laminal neurons believed to mediate such summation. Improved reliability costs acuity, but dark adapted bees already suffer optical blurring, and summation further degrades vision only slightly.
Low dark current InGaAs detector arrays for night vision and astronomy
NASA Astrophysics Data System (ADS)
MacDougal, Michael; Geske, Jon; Wang, Chad; Liao, Shirong; Getty, Jonathan; Holmes, Alan
2009-05-01
Aerius Photonics has developed large InGaAs arrays (1K x 1K and greater) with low dark currents for use in night vision applications in the SWIR regime. Aerius will present results of experiments to reduce the dark current density of their InGaAs detector arrays. By varying device designs and passivations, Aerius has achieved a dark current density below 1.0 nA/cm2 at 280K on small-pixel, detector arrays. Data is shown for both test structures and focal plane arrays. In addition, data from cryogenically cooled InGaAs arrays will be shown for astronomy applications.
Perception-based synthetic cueing for night vision device rotorcraft hover operations
NASA Astrophysics Data System (ADS)
Bachelder, Edward N.; McRuer, Duane
2002-08-01
Helicopter flight using night-vision devices (NVDs) is difficult to perform, as evidenced by the high accident rate associated with NVD flight compared to day operation. The approach proposed in this paper is to augment the NVD image with synthetic cueing, whereby the cues would emulate position and motion and appear to be actually occurring in physical space on which they are overlaid. Synthetic cues allow for selective enhancement of perceptual state gains to match the task requirements. A hover cue set was developed based on an analogue of a physical target used in a flight handling qualities tracking task, a perceptual task analysis for hover, and fundamentals of human spatial perception. The display was implemented on a simulation environment, constructed using a virtual reality device, an ultrasound head-tracker, and a fixed-base helicopter simulator. Seven highly trained helicopter pilots were used as experimental subjects and tasked to maintain hover in the presence of aircraft positional disturbances while viewing a synthesized NVD environment and the experimental hover cues. Significant performance improvements were observed when using synthetic cue augmentation. This paper demonstrates that artificial magnification of perceptual states through synthetic cueing can be an effective method of improving night-vision helicopter hover operations.
Georgia Academy for the Blind: Orientation and Mobility Curriculum. Crossroads to Independence.
ERIC Educational Resources Information Center
Berner, Catherine L., Comp.; Lindh, Peter D., Comp.
The Georgia Academy for the Blind curriculum guide covers orientation, cane skills, and travel skills. Chapter two, on low vision utilization, includes indoor, outdoor, and night low vision lessons checklists. Chapter three covers postural development and motor coordination. Chapter four, on concept development, covers body image, spatial…
Retinitis Pigmentosa and Education Issues
ERIC Educational Resources Information Center
Brown, Thomas J.
2005-01-01
Retinitis Pigmentosa includes a number of inherited diseases which usually result in blindness. The disease is progressive in nature and begins with the deterioration of cells in the eye responsible for peripheral vision. As the condition worsens there is a gradual loss of peripheral vision and night blindness. Proper educational planning requires…
Portable real-time color night vision
NASA Astrophysics Data System (ADS)
Toet, Alexander; Hogervorst, Maarten A.
2008-03-01
We developed a simple and fast lookup-table based method to derive and apply natural daylight colors to multi-band night-time images. The method deploys an optimal color transformation derived from a set of samples taken from a daytime color reference image. The colors in the resulting colorized multiband night-time images closely resemble the colors in the daytime color reference image. Also, object colors remain invariant under panning operations and are independent of the scene content. Here we describe the implementation of this method in two prototype portable dual band realtime night vision systems. One system provides co-aligned visual and near-infrared bands of two image intensifiers, the other provides co-aligned images from a digital image intensifier and an uncooled longwave infrared microbolometer. The co-aligned images from both systems are further processed by a notebook computer. The color mapping is implemented as a realtime lookup table transform. The resulting colorised video streams can be displayed in realtime on head mounted displays and stored on the hard disk of the notebook computer. Preliminary field trials demonstrate the potential of these systems for applications like surveillance, navigation and target detection.
77 FR 42704 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-20
... Vision Sensors, 12 AN/APG-78 Fire Control Radars (FCR) with Radar Electronics Unit (LONGBOW component... Target Acquisition and Designation Sight, 27 AN/AAR-11 Modernized Pilot Night Vision Sensors, 12 AN/APG... enhance the protection of key oil and gas infrastructure and platforms which are vital to U.S. and western...
MassMutual Partners with EP for a Dynamic Double Play
ERIC Educational Resources Information Center
Exceptional Parent, 2008
2008-01-01
In 2002 "Exceptional Parent" (EP) magazine had a vision--a vision of a dynamic, community outreach program that would raise the public's awareness about the special needs community. This program, now known as Disability Awareness Night, or DAN, would enlighten the public by calling attention to the dedication, perseverance, and the extraordinary…
2015-05-19
reported by U.S. Army aviators using NVG for night flights (Glick and Moser, 1974). It was initially, and incorrectly, called “brown eye syndrome ...112 FREQUENCY Never Rarely Occasionally Often Eye irritation Eye pain Blurred vision Dry eye ... Eye pain Blurred vision Dry eye Light sensitivity j. Since your last contact lens review, did you experience any of the following
NASA Astrophysics Data System (ADS)
Durfee, David; Johnson, Walter; McLeod, Scott
2007-04-01
Un-cooled microbolometer sensors used in modern infrared night vision systems such as driver vehicle enhancement (DVE) or thermal weapons sights (TWS) require a mechanical shutter. Although much consideration is given to the performance requirements of the sensor, supporting electronic components and imaging optics, the shutter technology required to survive in combat is typically the last consideration in the system design. Electro-mechanical shutters used in military IR applications must be reliable in temperature extremes from a low temperature of -40°C to a high temperature of +70°C. They must be extremely light weight while having the ability to withstand the high vibration and shock forces associated with systems mounted in military combat vehicles, weapon telescopic sights, or downed unmanned aerial vehicles (UAV). Electro-mechanical shutters must have minimal power consumption and contain circuitry integrated into the shutter to manage battery power while simultaneously adapting to changes in electrical component operating parameters caused by extreme temperature variations. The technology required to produce a miniature electro-mechanical shutter capable of fitting into a rifle scope with these capabilities requires innovations in mechanical design, material science, and electronics. This paper describes a new, miniature electro-mechanical shutter technology with integrated power management electronics designed for extreme service infra-red night vision systems.
NASA Astrophysics Data System (ADS)
Loro, Stephen Lee
This study was designed to examine moon illumination, moon angle, cloud cover, sky glow, and Night Vision Goggle (NVG) flight performance to determine possible effects. The research was a causal-comparative design. The sample consisted of 194 Fort Rucker Initial Entry Rotary Wing NVG flight students being observed by 69 NVG Instructor Pilots. The students participated in NVG flight training from September 1992 through January 1993. Data were collected using a questionnaire. Observations were analyzed using a Kruskal-Wallis one-way analysis of variance and a Wilcox matched pairs signed-ranks test for difference. Correlations were analyzed using Pearson's r. The analyses results indicated that performance at high moon illumination levels is superior to zero moon illumination, and in most task maneuvers, superior to >0%--50% moon illumination. No differences were found in performance at moon illumination levels above 50%. Moon angle had no effect on night vision goggle flight performance. Cloud cover and sky glow have selective effects on different maneuvers. For most task maneuvers, cloud cover does not affect performance. Overcast cloud cover had a significant effect on seven of the 14 task maneuvers. Sky glow did not affect eight out of 14 task maneuvers at any level of sky glow.
Källhammer, Jan-Erik; Smith, Kip
2012-08-01
We investigated five contextual variables that we hypothesized would influence driver acceptance of alerts to pedestrians issued by a night vision active safety system to inform the specification of the system's alerting strategies. Driver acceptance of automotive active safety systems is a key factor to promote their use and implies a need to assess factors influencing driver acceptance. In a field operational test, 10 drivers drove instrumented vehicles equipped with a preproduction night vision system with pedestrian detection software. In a follow-up experiment, the 10 drivers and 25 additional volunteers without experience with the system watched 57 clips with pedestrian encounters gathered during the field operational test. They rated the acceptance of an alert to each pedestrian encounter. Levels of rating concordance were significant between drivers who experienced the encounters and participants who did not. Two contextual variables, pedestrian location and motion, were found to influence ratings. Alerts were more accepted when pedestrians were close to or moving toward the vehicle's path. The study demonstrates the utility of using subjective driver acceptance ratings to inform the design of active safety systems and to leverage expensive field operational test data within the confines of the laboratory. The design of alerting strategies for active safety systems needs to heed the driver's contextual sensitivity to issued alerts.
Enhanced modeling and simulation of EO/IR sensor systems
NASA Astrophysics Data System (ADS)
Hixson, Jonathan G.; Miller, Brian; May, Christopher
2015-05-01
The testing and evaluation process developed by the Night Vision and Electronic Sensors Directorate (NVESD) Modeling and Simulation Division (MSD) provides end to end systems evaluation, testing, and training of EO/IR sensors. By combining NV-LabCap, the Night Vision Integrated Performance Model (NV-IPM), One Semi-Automated Forces (OneSAF) input sensor file generation, and the Night Vision Image Generator (NVIG) capabilities, NVESD provides confidence to the M&S community that EO/IR sensor developmental and operational testing and evaluation are accurately represented throughout the lifecycle of an EO/IR system. This new process allows for both theoretical and actual sensor testing. A sensor can be theoretically designed in NV-IPM, modeled in NV-IPM, and then seamlessly input into the wargames for operational analysis. After theoretical design, prototype sensors can be measured by using NV-LabCap, then modeled in NV-IPM and input into wargames for further evaluation. The measurement process to high fidelity modeling and simulation can then be repeated again and again throughout the entire life cycle of an EO/IR sensor as needed, to include LRIP, full rate production, and even after Depot Level Maintenance. This is a prototypical example of how an engineering level model and higher level simulations can share models to mutual benefit.
Definition of display/control requirements for assault transport night/adverse weather capability
NASA Technical Reports Server (NTRS)
Milelli, R. J.; Mowery, G. W.; Pontelandolfo, C.
1982-01-01
A Helicopter Night Vision System was developed to improve low-altitude night and/or adverse weather assult transport capabilities. Man-in-the-loop simulation experiments were performed to define the minimum display and control requirements for the assult transport mission and investigate forward looking infrared sensor requirements, along with alternative displays such as panel mounted displays (PMD) helmet mounted displays (HMD), and integrated control display units. Also explored were navigation requirements, pilot/copilot interaction, and overall cockpit arrangement. Pilot use of an HMD and copilot use of a PMD appear as both the preferred and most effective night navigation combination.
Improvement of Hungarian Joint Terminal Attack Program
2013-06-13
LST Laser Spot Tracker NVG Night Vision Goggle ROMAD Radio Operator Maintainer and Driver ROVER Remotely Operated Video Enhanced Receiver TACP...visual target designation. The other component consists of a laser spot tracker (LST), which identifies targets by tracking laser energy reflecting...capability for every type of night time missions, laser spot tracker for laser spot search missions, remotely operated video enhanced receiver
Photographic Assessment of Dark Spots in Night Vision Device Images
1998-01-01
Ronchi, V., (1957), Optics, the science of vision, New York: New York University Press. BIOGRAPHY Peter L. Marasco came to the U.S. Air Force in 1991 as a...optical test methods. Mr. Marasco received a BS degree from the University of Rochester in 1991 and an MS degree from the University of Arizona in 1993
Is More Better? - Night Vision Enhancement System's Pedestrian Warning Modes and Older Drivers.
Brown, Timothy; He, Yefei; Roe, Cheryl; Schnell, Thomas
2010-01-01
Pedestrian fatalities as a result of vehicle collisions are much more likely to happen at night than during day time. Poor visibility due to darkness is believed to be one of the causes for the higher vehicle collision rate at night. Existing studies have shown that night vision enhancement systems (NVES) may improve recognition distance, but may increase drivers' workload. The use of automatic warnings (AW) may help minimize workload, improve performance, and increase safety. In this study, we used a driving simulator to examine performance differences of a NVES with six different configurations of warning cues, including: visual, auditory, tactile, auditory and visual, tactile and visual, and no warning. Older drivers between the ages of 65 and 74 participated in the study. An analysis based on the distance to pedestrian threat at the onset of braking response revealed that tactile and auditory warnings performed the best, while visual warnings performed the worst. When tactile or auditory warnings were presented in combination with visual warning, their effectiveness decreased. This result demonstrated that, contrary to general sense regarding warning systems, multi-modal warnings involving visual cues degraded the effectiveness of NVES for older drivers.
Is More Better? — Night Vision Enhancement System’s Pedestrian Warning Modes and Older Drivers
Brown, Timothy; He, Yefei; Roe, Cheryl; Schnell, Thomas
2010-01-01
Pedestrian fatalities as a result of vehicle collisions are much more likely to happen at night than during day time. Poor visibility due to darkness is believed to be one of the causes for the higher vehicle collision rate at night. Existing studies have shown that night vision enhancement systems (NVES) may improve recognition distance, but may increase drivers’ workload. The use of automatic warnings (AW) may help minimize workload, improve performance, and increase safety. In this study, we used a driving simulator to examine performance differences of a NVES with six different configurations of warning cues, including: visual, auditory, tactile, auditory and visual, tactile and visual, and no warning. Older drivers between the ages of 65 and 74 participated in the study. An analysis based on the distance to pedestrian threat at the onset of braking response revealed that tactile and auditory warnings performed the best, while visual warnings performed the worst. When tactile or auditory warnings were presented in combination with visual warning, their effectiveness decreased. This result demonstrated that, contrary to general sense regarding warning systems, multi-modal warnings involving visual cues degraded the effectiveness of NVES for older drivers. PMID:21050616
Analysis of Risk Compensation Behavior on Night Vision Enhancement System
NASA Astrophysics Data System (ADS)
Hiraoka, Toshihiro; Masui, Junya; Nishikawa, Seimei
Advanced driver assistance systems (ADAS) such as a forward obstacle collision warning system (FOCWS) and a night vision enhancement system (NVES) aim to decrease driver's mental workload and enhance vehicle safety by provision of useful information to support driver's perception process and judgment process. On the other hand, the risk homeostasis theory (RHT) cautions that an enhanced safety and a reduced risk would cause a risk compensation behavior such as increasing the vehicle velocity. Therefore, the present paper performed the driving simulator experiments to discuss dependence on the NVES and emergence of the risk compensation behavior. Moreover, we verified the side-effects of spontaneous behavioral adaptation derived from the presentation of the fuel-consumption meter on the risk compensation behavior.
2001-01-01
translated is ensured. For example, autosomal dominant retinitis pigmentosa (ADRP) is a genetic disorder that results in the degeneration of night and...GLOSSARY A adenosine ADRP Autosomal Dominant Retinitis Pigmentosa C cytidine DNA deoxyribonucleic acid G guanosine mRNA messenger RNA OH hydroxyl PCR...peripheral vision. The genetic defect lies in one, or both copies of a gene required for normal retinal structure and vision, rhodopsin. Triplex
Target Presentation Methodology for Tactical Field Evaluations
1976-10-01
to making their observations. Finally, Sternberp and Banks J (during an investigation of search effectiveness with passive night vision...factors are likely to be more important in the acquisition process. ^J. Stemberg and J. Banks . Search Fffcstivcncss viih hwoive Nipht Vision...differently-colored low-contrast uni- forms (green field uniform and black pajama -type uniform) in a Jungle environment. They found that the
Visual function at altitude under night vision assisted conditions.
Vecchi, Diego; Morgagni, Fabio; Guadagno, Anton G; Lucertini, Marco
2014-01-01
Hypoxia, even mild, is known to produce negative effects on visual function, including decreased visual acuity and sensitivity to contrast, mostly in low light. This is of special concern when night vision devices (NVDs) are used during flight because they also provide poor images in terms of resolution and contrast. While wearing NVDs in low light conditions, 16 healthy male aviators were exposed to a simulated altitude of 12,500 ft in a hypobaric chamber. Snellen visual acuity decreased in normal light from 28.5 +/- 4.2/20 (normoxia) to 37.2 +/- 7.4/20 (hypoxia) and, in low light, from 33.8 +/- 6.1/20 (normoxia) to 42.2 +/- 8.4/20 (hypoxia), both at a significant level. An association was found between blood oxygen saturation and visual acuity without significance. No changes occurred in terms of sensitivity to contrast. Our data demonstrate that mild hypoxia is capable of affecting visual acuity and the photopic/high mesopic range of NVD-aided vision. This may be due to several reasons, including the sensitivity to hypoxia of photoreceptors and other retinal cells. Contrast sensitivity is possibly preserved under NVD-aided vision due to its dependency on the goggles' gain.
Zobor, Ditta; Balousha, Ghassan; Baumann, Britta; Wissinger, Bernd
2014-01-01
Retinitis pigmentosa (RP) is a heterogenous group of inherited retinal degenerations caused by mutations in at least 45 genes. Recently, the FAM161A gene was identified as the causative gene for RP28, an autosomal recessive form of RP. We performed a clinical and molecular genetic study of a consanguineous Palestinian family with two three siblings affected with retinitis pigmentosa. DNA samples were collected from the index patient, his father, his affected sister, and two non-affected brothers. DNA sample from the index was subjected to high resolution genome-wide SNP array. Assuming identity-by-descent in this consanguineous family we applied homozygosity mapping to identify disease causing genes. The index patient reported night blindness since the age of 20 years, followed by moderate disease progression with decrease of peripheral vision, the development of photophobia and later on reduced central vision. At the age of 40 his visual acuity was counting fingers (CF) for both eyes, color discrimination was not possible and his visual fields were severely constricted. Funduscopic examination revealed a typical appearance of advanced RP with optic disc pallor, narrowed retinal vessels, bone-spicule like pigmentary changes in the mid-periphery and atrophic changes in the macula. His younger affected brother (37 years) was reported with overall milder symptoms, while the youngest sister (21 years) reported problems only with night vision. Applying high-density SNP arrays we identified several homozygous genomic regions one of which included the recently identified FAM161A gene mutated in RP28-linked autosomal recessive RP. Sequencing analysis revealed the presence of a novel homozygous nonsense mutation, c.1003C>T/p.R335X in the index patient and the affected sister. We identified an RP28-linked RP family in the Palestinian population caused by a novel nonsense mutation in FAM161A. RP in this family shows a typical disease onset with moderate to rapid progression into severe visual impairment including central vision in the index and overall milder symptoms in the younger brother and sister.
Zobor, Ditta; Balousha, Ghassan; Baumann, Britta
2014-01-01
Purpose: Retinitis pigmentosa (RP) is a heterogenous group of inherited retinal degenerations caused by mutations in at least 45 genes. Recently, the FAM161A gene was identified as the causative gene for RP28, an autosomal recessive form of RP. Methods: We performed a clinical and molecular genetic study of a consanguineous Palestinian family with two three siblings affected with retinitis pigmentosa. DNA samples were collected from the index patient, his father, his affected sister, and two non-affected brothers. DNA sample from the index was subjected to high resolution genome-wide SNP array. Assuming identity-by-descent in this consanguineous family we applied homozygosity mapping to identify disease causing genes. Results: The index patient reported night blindness since the age of 20 years, followed by moderate disease progression with decrease of peripheral vision, the development of photophobia and later on reduced central vision. At the age of 40 his visual acuity was counting fingers (CF) for both eyes, color discrimination was not possible and his visual fields were severely constricted. Funduscopic examination revealed a typical appearance of advanced RP with optic disc pallor, narrowed retinal vessels, bone-spicule like pigmentary changes in the mid-periphery and atrophic changes in the macula. His younger affected brother (37 years) was reported with overall milder symptoms, while the youngest sister (21 years) reported problems only with night vision. Applying high-density SNP arrays we identified several homozygous genomic regions one of which included the recently identified FAM161A gene mutated in RP28-linked autosomal recessive RP. Sequencing analysis revealed the presence of a novel homozygous nonsense mutation, c.1003C>T/p.R335X in the index patient and the affected sister. Conclusion: We identified an RP28-linked RP family in the Palestinian population caused by a novel nonsense mutation in FAM161A. RP in this family shows a typical disease onset with moderate to rapid progression into severe visual impairment including central vision in the index and overall milder symptoms in the younger brother and sister. PMID:24520187
Training for Night Operations - Research Challenges and Opportunities
2012-08-08
Training and Simulation Conference Exhibits and Visuals by Type ……………..……... 1 Figure 2: Radiant Sensitivity of Intensifiers Currently Used in Night Vision...wavelengths across Figure 2. Radiant Sensitivity of Intensifiers the entire radiant sensitivity band. In either case, in order to be Currently...the projector/display technology and NVGs used. NVGs are very sensitive to any light within their band of radiant sensitivity . The intensifier
Nonverbal Communication and Aircrew Coordination in Army Aviation: Annotated Bibliography
2006-06-01
limited in-cockpit visibility resulting from night and night vision goggle (NVG) use. The resulting reductions in nonverbal communication may have an...Readiness Center (USACRC) investigates Army aircraft accidents, and has included combat losses in their investigations. Their work continues to reveal a high...incidence of crew coordination errors that contribute to loss of life and equipment. A USACRC spokesman stated that, "Eighty percent of our accidents
2012-05-01
undergo wavefront-guided (WFG) photorefractive keratectomy ( PRK ), WFG laser in situ keratomileusis ( LASIK ), wavefront optimized (WFO) PRK or WFO...Military, Refractive Surgery, PRK , LASIK , Night Vision, Wavefront Optimized, Wavefront Guided, Visual Performance, Quality of Vision, Outcomes...military. In a prospective, randomized treatment trial we will enroll 224 nearsighted soldiers to WFG photorefractive keratectomy ( PRK ), WFG LASIK , WFO PRK
2013-05-01
and Sensors Directorate. • Study participants and physicians select treatment: PRK or LASIK . WFG vs . WFO treatment modality is randomized. The...to undergo wavefront-guided (WFG) photorefractive keratectomy ( PRK ), WFG laser in situ keratomileusis ( LASIK ), wavefront optimized (WFO) PRK or WFO...TERMS Military, Refractive Surgery, PRK , LASIK , Night Vision, Wavefront Optimized, Wavefront Guided, Visual Performance, Quality of Vision, Outcomes
Night-Vision Goggle Visual Performance During 12 Hours at 10,000 ft Altitude at Night Conditions
2008-03-01
relative ta the use .of head-phanes (OR= 1.74, CI= 0.64-4.71), attendance ta cancerts (OR= 2.20, CI= 0.62-7.82), .or matar sparts (OR= 1.02, CI= 0.21-4.77...performance of low-grade hypaxia exposu re at 10,000 ft duri~g 12 haurs night condltlans. Methods: Hypabaric expasures in a dark environment simulating a...visian gaggle at an altitude .of 10,000 ft In a dark envlranment are described. [418] ROLL, PITCH, AND YAW OFTHE HEAD AS IT TRACKS VISUAL AND
Lateralized activation of Cluster N in the brains of migratory songbirds
Liedvogel, Miriam; Feenders, Gesa; Wada, Kazuhiro; Troje, Nikolaus F.; Jarvis, Erich D.; Mouritsen, Henrik
2008-01-01
Cluster N is a cluster of forebrain regions found in night-migratory songbirds that shows high activation of activity-dependent gene expression during night-time vision. We have suggested that Cluster N may function as a specialized night-vision area in night-migratory birds and that it may be involved in processing light-mediated magnetic compass information. Here, we investigated these ideas. We found a significant lateralized dominance of Cluster N activation in the right hemisphere of European robins (Erithacus rubecula). Activation predominantly originated from the contralateral (left) eye. Garden warblers (Sylvia borin) tested under different magnetic field conditions and under monochromatic red light did not show significant differences in Cluster N activation. In the fairly sedentary Sardinian warbler (Sylvia melanocephala), which belongs to the same phyolgenetic clade, Cluster N showed prominent activation levels, similar to that observed in garden warblers and European robins. Thus, it seems that Cluster N activation occurs at night in all species within predominantly migratory groups of birds, probably because such birds have the capability of switching between migratory and sedentary life styles. The activation studies suggest that although Cluster N is lateralized, as is the dependence on magnetic compass orientation, either Cluster N is not involved in magnetic processing or the magnetic modulations of the primary visual signal, forming the basis for the currently supported light-dependent magnetic compass mechanism, are relatively small such that activity-dependent gene expression changes are not sensitive enough to pick them up. PMID:17331212
Cellular phone use while driving at night.
Vivoda, Jonathon M; Eby, David W; St Louis, Renée M; Kostyniuk, Lidia P
2008-03-01
Use of a cellular phone has been shown to negatively affect one's attention to the driving task, leading to an increase in crash risk. At any given daylight hour, about 6% of US drivers are actively talking on a hand-held cell phone. However, previous surveys have focused only on cell phone use during the day. Driving at night has been shown to be a riskier activity than driving during the day. The purpose of the current study was to assess the rate of hand-held cellular phone use while driving at night, using specialized night vision equipment. In 2006, two statewide direct observation survey waves of nighttime cellular phone use were conducted in Indiana utilizing specialized night vision equipment. Combined results of driver hand-held cellular phone use from both waves are presented in this manuscript. The rates of nighttime cell phone use were similar to results found in previous daytime studies. The overall rate of nighttime hand-held cellular phone use was 5.8 +/- 0.6%. Cellular phone use was highest for females and for younger drivers. In fact, the highest rate observed during the study (of 11.9%) was for 16-to 29-year-old females. The high level of cellular phone use found within the young age group, coupled with the increased crash risk associated with cellular phone use, nighttime driving, and for young drivers in general, suggests that this issue may become an important transportation-related concern.
Bhati, Hitesh; Manjusha, R
2015-01-01
Senile cataract is the leading cause of blindness according to the World Health Report, 1998. Till date no accepted medical treatment is available for cataract. In Ayurveda visual disturbances are described in the context of Timira, Kacha and Linganasha. Timira is an early stage characterized by blurring of vision and Linganasha is end stage where complete loss of vision occurs. Ancient scholars have advocated different Anjana application and oral medications in the Timira and Kacha stage. To study the efficacy of test drugs Triphaladi Ghana Vati and Elaneer Kuzhambu Anjana in immature cataract. In this trial patients having Senile Immature Cataract were randomized with equal probability to one of the two treatment Groups A and B (n = 20 each). In Group A Triphaladi Ghana Vati 500 mg internally for 3 months and in Group B Triphaladi Ghana Vati 500 mg internally and Elaneer Kuzhambu Anjana for local application were given. Assessment was done on the basis of blurring of vision, visualization of nonexisting things, difficulty in bright light and dim light or night vision, distant visual acuity, pinhole vision, best corrected visual acuity and cataract grading on slit lamp. Both groups showed statistically significant changes in blurring of vision, difficulty in glare, daytime and bright light, distant visual activity, pinhole vision, and best-corrected visual acuity. Group B also showed significant changes in difficulty in night time, visualization of nonexisting things and in nuclear cataract. The study establishes that test drugs can reduce and control the progress of immature cataract, and combined therapy was found more effective. Chakshushya Rasayana, early diagnosis and proper management on Doshic lines can prevent arrest or delay senile cataract.
Bhati, Hitesh; Manjusha, R.
2015-01-01
Introduction: Senile cataract is the leading cause of blindness according to the World Health Report, 1998. Till date no accepted medical treatment is available for cataract. In Ayurveda visual disturbances are described in the context of Timira, Kacha and Linganasha. Timira is an early stage characterized by blurring of vision and Linganasha is end stage where complete loss of vision occurs. Ancient scholars have advocated different Anjana application and oral medications in the Timira and Kacha stage. Aim: To study the efficacy of test drugs Triphaladi Ghana Vati and Elaneer Kuzhambu Anjana in immature cataract. Materials and Methods: In this trial patients having Senile Immature Cataract were randomized with equal probability to one of the two treatment Groups A and B (n = 20 each). In Group A Triphaladi Ghana Vati 500 mg internally for 3 months and in Group B Triphaladi Ghana Vati 500 mg internally and Elaneer Kuzhambu Anjana for local application were given. Assessment was done on the basis of blurring of vision, visualization of nonexisting things, difficulty in bright light and dim light or night vision, distant visual acuity, pinhole vision, best corrected visual acuity and cataract grading on slit lamp. Results: Both groups showed statistically significant changes in blurring of vision, difficulty in glare, daytime and bright light, distant visual activity, pinhole vision, and best-corrected visual acuity. Group B also showed significant changes in difficulty in night time, visualization of nonexisting things and in nuclear cataract. Conclusion: The study establishes that test drugs can reduce and control the progress of immature cataract, and combined therapy was found more effective. Chakshushya Rasayana, early diagnosis and proper management on Doshic lines can prevent arrest or delay senile cataract. PMID:27313415
Limits of colour vision in dim light.
Kelber, Almut; Lind, Olle
2010-09-01
Humans and most vertebrates have duplex retinae with multiple cone types for colour vision in bright light, and one single rod type for achromatic vision in dim light. Instead of comparing signals from multiple spectral types of photoreceptors, such species use one highly sensitive receptor type thus improving the signal-to-noise ratio at night. However, the nocturnal hawkmoth Deilephila elpenor, the nocturnal bee Xylocopa tranquebarica and the nocturnal gecko Tarentola chazaliae can discriminate colours at extremely dim light intensities. To be able to do so, they sacrifice spatial and temporal resolution in favour of colour vision. We review what is known about colour vision in dim light, and compare colour vision thresholds with the optical sensitivity of the photoreceptors in selected animal species with lens and compound eyes. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.
Mallipatna, Ashwin; Vinekar, Anand; Jayadev, Chaitra; Dabir, Supriya; Sivakumar, Munsusamy; Krishnan, Narasimha; Mehta, Pooja; Berendschot, Tos; Yadav, Naresh Kumar
2015-07-01
Optical coherence tomography (OCT) is an important imaging tool assessing retinal architecture. In this article, we report a single centers experience of using handheld spectral domain (SD)-OCT in a pediatric population using the Envisu 2300 (Bioptigen Inc., Research Triangle Park, NC, USA). We studied SD-OCT images from 975 patients imaged from January 2011 to December 2014. The variety of cases that underwent an SD-OCT was analyzed. Cases examples from different case scenarios were selected to showcase unique examples of many diseases. Three hundred and sixty-eight infants (37.7%) were imaged for retinopathy of prematurity, 362 children (37.1%) underwent the test for evaluation of suboptimal vision or an unexplained vision loss, 126 children (12.9%) for evaluation of nystagmus or night blindness, 54 children (5.5%) for an intraocular tumor or a mass lesion such as retinoblastoma, and 65 children (6.7%) for other diseases of the pediatric retina. The unique findings in the retinal morphology seen with some of these diseases are discussed. The handheld SD-OCT is useful in the evaluation of the pediatric retinal diseases. The test is useful in the assessment of vision development in premature children, evaluation of unexplained vision loss and amblyopia, nystagmus and night blindness, and intraocular tumors (including retinoblastoma).
Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Kandhro, Ghulam Abbas; Baig, Jameel Ahmed; Shah, Abdul Qadir; Khan, Sumaira; Kolachi, Nida Fatima; Wadhwa, Sham Kumar; Shah, Faheem
2011-01-01
The most common cause of blindness in developing countries is vitamin A deficiency. The World Health Organization (WHO) estimates 13.8 million children have some degree of visual loss related to vitamin A deficiency. The causes of night blindness in children are multifactorial and particular consideration has been given to childhood nutritional deficiency, which is the most common problem found in underdeveloped countries. Such deficiency can result in physiological and pathological processes that in turn influence biological sample composition. Vitamin and mineral deficiency prevents more than two billion people from achieving their full intellectual and physical potential. This study was designed to compare the levels of magnesium (Mg), calcium (Ca), potassium (K), and sodium (Na) in scalp hair, serum, blood, and urine of night blindness children in two age groups, (1-5) and (6-10) years, of both genders comparing them to sex- and age-matched controls. A microwave assisted wet acid digestion procedure was developed as a sample pretreatment for the determination of Mg, Ca, K, and Na in biological samples of children with night blindness. The proposed method was validated by using conventional wet digestion and certified reference samples of hair, serum, blood, and urine. The digests of all biological samples were analysed for Mg, Ca, K, and Na by flame atomic absorption spectrometry (FAAS) using an air/acetylene flame. The results indicated significantly lower levels of Mg, Ca, and K in the biological samples (blood, serum, and scalp hair) of male and female children with night blindness and higher values of Na compared with control subjects of both genders. These data present guidance to clinicians and other professionals investigating deficiency of essential mineral elements in biological samples (scalp hair, serum, and blood) of children with night blindness.
Genetics Home Reference: Refsum disease
... disease is caused by an eye disorder called retinitis pigmentosa . This disorder affects the retina , the light-sensitive ... the retina gradually deteriorate. The first sign of retinitis pigmentosa is usually a loss of night vision, which ...
Fouks, J D; Besnard, S; Signac, L; Meurice, J C; Neau, J P; Paquereau, J
2004-04-01
The present paper exposes algorithmic results providing a vision about sleep functions which complements biological theory and experiments. Derived from the algorithmic theory of information, the theory of adaptation aims at quantifying how an inherited or acquired piece of knowledge helps individuals to survive. It gives a scale of complexity for survival problems and proves that some of them can only be solved by a dynamical management of memory associating continuous learning and forgetting methods. In this paper we explain how a virtual robot "Picota" has been designed to simulate the behavior of a living hen. In order to survive in its synthetical environment, our robot must recognize good seeds from bad ones, and should take rest during night periods. Within this frame, and facing the rapid evolution of to-be-recognized forms, the best way to equilibrate the energetic needs of the robot and ensure survival is to use the nightly rest to reorganize the pieces of data acquired during the daily learning, and to trash the less useful ones. Thanks to this time sharing, the same circuits can be used for both daily learning and nightly forgetting and thus costs are lower; however, this also forces the system to "paralyse" the virtual robot, and therefore the night algorithm is reminiscent of paradoxical (REM) sleep. The algorithm of the robot takes advantage of the alternation between wakefulness or activity and the rest period. This diagram quite accurately recalls the REM period. In the future, the convergence between the neurophysiology of sleep and the theory of complexity may give us a new line of research in order to elucidate sleep functions.
NASA Astrophysics Data System (ADS)
Guan, Wen; Li, Li; Jin, Weiqi; Qiu, Su; Zou, Yan
2015-10-01
Extreme-Low-Light CMOS has been widely applied in the field of night-vision as a new type of solid image sensor. But if the illumination in the scene has drastic changes or the illumination is too strong, Extreme-Low-Light CMOS can't both clearly present the high-light scene and low-light region. According to the partial saturation problem in the field of night-vision, a HDR image fusion algorithm based on the Laplace Pyramid was researched. The overall gray value and the contrast of the low light image is very low. We choose the fusion strategy based on regional average gradient for the top layer of the long exposure image and short exposure image, which has rich brightness and textural features. The remained layers which represent the edge feature information of the target are based on the fusion strategy based on regional energy. In the process of source image reconstruction with Laplacian pyramid image, we compare the fusion results with four kinds of basal images. The algorithm is tested using Matlab and compared with the different fusion strategies. We use information entropy, average gradient and standard deviation these three objective evaluation parameters for the further analysis of the fusion result. Different low illumination environment experiments show that the algorithm in this paper can rapidly get wide dynamic range while keeping high entropy. Through the verification of this algorithm features, there is a further application prospect of the optimized algorithm. Keywords: high dynamic range imaging, image fusion, multi-exposure image, weight coefficient, information fusion, Laplacian pyramid transform.
Rod electrical coupling is controlled by a circadian clock and dopamine in mouse retina
Jin, Nan Ge; Chuang, Alice Z; Masson, Philippe J; Ribelayga, Christophe P
2015-01-01
Key points Rod photoreceptors play a key role in vision in dim light; in the mammalian retina, although rods are anatomically connected or coupled by gap junctions, a type of electrical synapse, the functional importance and regulation of rod coupling has remained elusive. We have developed a new technique in the mouse: perforated patch-clamp recording of rod inner segments in isolated intact retinae maintained by superfusion. We find that rod electrical coupling is controlled by a circadian clock and dopamine, and is weak during the day and stronger at night. The results also indicate that the signal-to-noise ratio for a dim light response is increased at night because of coupling. Our observations will provide a framework for understanding the daily variations in human vision as well as the basis of specific retinal malfunctions. Abstract Rod single-photon responses are critical for vision in dim light. Electrical coupling via gap junction channels shapes the light response properties of vertebrate photoreceptors, but the regulation of rod coupling and its impact on the single-photon response have remained unclear. To directly address these questions, we developed a perforated patch-clamp recording technique and recorded from single rod inner segments in isolated intact neural mouse retinae, maintained by superfusion. Experiments were conducted at different times of the day or under constant environmental conditions, at different times across the circadian cycle. We show that rod electrical coupling is regulated by a circadian clock and dopamine, so that coupling is weak during the day and strong at night. Altogether, patch-clamp recordings of single-photon responses in mouse rods, tracer coupling, receptive field measurements and pharmacological manipulations of gap junction and dopamine receptor activity provide compelling evidence that rod coupling is modulated in a circadian manner. These data are consistent with computer modelling. At night, single-photon responses are smaller due to coupling, but the signal-to-noise ratio for a dim (multiphoton) light response is increased at night because of signal averaging between coupled rods. PMID:25616058
NASA Technical Reports Server (NTRS)
2005-01-01
If it were 50 years ago, NASA's contribution to rock and roll could have been more than just the all-astronaut rock band, Max Q, composed of six NASA astronauts, all of whom have flown aboard the Space Shuttle. If it were 50 years ago, a new NASA spinoff technology, Synthetic Vision, would likely have been able to prevent the fateful, small plane crash that killed rock and roll legends Buddy Holly, Ritchie Valens, and The Big Bopper on that stormy night in 1959. Synthetic Vision is a new cockpit display system that helps pilots fly through bad weather, and it has incredible life-saving potential. In 1997, the White House Commission on Aviation Safety and Security created NASA s Aviation Safety and Security Program (AvSSP) with the aim of sounding the depths of NASA s cutting-edge aviation advances and history of successes. The AvSSP decided to use NASA technology to cut the rate of fatal aviation accidents that occur because of lowered visibility and spatial disorientation, common problems that arise in poor weather conditions, in the dark, or with inexperienced pilots.
Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.
Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro
2012-03-01
To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.
Evidence of Newell's Shearwater breeding in Puna District, Hawaii
Reynolds, Michelle H.; Ritchotte, George L.
1997-01-01
Nocturnal surveys using auditory cues and night-vision equipment were conducted during the seabird breeding season in 1993 to determine use of inland areas in the Puna District, Hawaii by Newell's Shearwater (Puffinus auricularus newelli). Two hundred sixty Newell's Shearwater auditory or visual detections were made during 275 survey hours from 23 Jul. 1993 - 20 Sep. 1993. Mean detection rates were 1.26 birds/h at Puulena Crater (n = 160 Newell's Shearwater detections), 1.05 birds/h at Heiheiahulu (n = 99) and 0.04 birds/ h at Puu Kaliu (n = 2). Vocalizing peaked between 50 and 90 min after sunset and 4 h before sunrise. Although night-vision equipment was used on most of the seabird surveys, only 4% of seabirds were detected visually. Two road-killed birds collected in Puna in June 1993, and four burrows located in Puulena Crater after the 1994 breeding season, provided additional evidence of breeding.
Swap intensified WDR CMOS module for I2/LWIR fusion
NASA Astrophysics Data System (ADS)
Ni, Yang; Noguier, Vincent
2015-05-01
The combination of high resolution visible-near-infrared low light sensor and moderate resolution uncooled thermal sensor provides an efficient way for multi-task night vision. Tremendous progress has been made on uncooled thermal sensors (a-Si, VOx, etc.). It's possible to make a miniature uncooled thermal camera module in a tiny 1cm3 cube with <1W power consumption. For silicon based solid-state low light CCD/CMOS sensors have observed also a constant progress in terms of readout noise, dark current, resolution and frame rate. In contrast to thermal sensing which is intrinsic day&night operational, the silicon based solid-state sensors are not yet capable to do the night vision performance required by defense and critical surveillance applications. Readout noise, dark current are 2 major obstacles. The low dynamic range at high sensitivity mode of silicon sensors is also an important limiting factor, which leads to recognition failure due to local or global saturations & blooming. In this context, the image intensifier based solution is still attractive for the following reasons: 1) high gain and ultra-low dark current; 2) wide dynamic range and 3) ultra-low power consumption. With high electron gain and ultra low dark current of image intensifier, the only requirement on the silicon image pickup device are resolution, dynamic range and power consumption. In this paper, we present a SWAP intensified Wide Dynamic Range CMOS module for night vision applications, especially for I2/LWIR fusion. This module is based on a dedicated CMOS image sensor using solar-cell mode photodiode logarithmic pixel design which covers a huge dynamic range (> 140dB) without saturation and blooming. The ultra-wide dynamic range image from this new generation logarithmic sensor can be used directly without any image processing and provide an instant light accommodation. The complete module is slightly bigger than a simple ANVIS format I2 tube with <500mW power consumption.
Collaboration between human and nonhuman players in Night Vision Tactical Trainer-Shadow
NASA Astrophysics Data System (ADS)
Berglie, Stephen T.; Gallogly, James J.
2016-05-01
The Night Vision Tactical Trainer - Shadow (NVTT-S) is a U.S. Army-developed training tool designed to improve critical Manned-Unmanned Teaming (MUMT) communication skills for payload operators in Unmanned Aerial Sensor (UAS) crews. The trainer is composed of several Government Off-The-Shelf (GOTS) simulation components and takes the trainee through a series of escalating engagements using tactically relevant, realistically complex, scenarios involving a variety of manned, unmanned, aerial, and ground-based assets. The trainee is the only human player in the game and he must collaborate, from his web-based mock operating station, with various non-human players via spoken natural language over simulated radio in order to execute the training missions successfully. Non-human players are modeled in two complementary layers - OneSAF provides basic background behaviors for entities while NVTT provides higher level models that control entity actions based on intent extracted from the trainee's spoken natural dialog with game entities. Dialog structure is modeled based on Army standards for communication and verbal protocols. This paper presents an architecture that integrates the U.S. Army's Night Vision Image Generator (NVIG), One Semi- Automated Forces (OneSAF), a flight dynamics model, as well as Commercial Off The Shelf (COTS) speech recognition and text to speech products to effect an environment with sufficient entity counts and fidelity to enable meaningful teaching and reinforcement of critical communication skills. It further demonstrates the model dynamics and synchronization mechanisms employed to execute purpose-built training scenarios, and to achieve ad-hoc collaboration on-the-fly between human and non-human players in the simulated environment.
A real-time monitoring system for night glare protection
NASA Astrophysics Data System (ADS)
Ma, Jun; Ni, Xuxiang
2010-11-01
When capturing a dark scene with a high bright object, the monitoring camera will be saturated in some regions and the details will be lost in and near these saturated regions because of the glare vision. This work aims at developing a real-time night monitoring system. The system can decrease the influence of the glare vision and gain more details from the ordinary camera when exposing a high-contrast scene like a car with its headlight on during night. The system is made up of spatial light modulator (The liquid crystal on silicon: LCoS), image sensor (CCD), imaging lens and DSP. LCoS, a reflective liquid crystal, can modular the intensity of reflective light at every pixel as a digital device. Through modulation function of LCoS, CCD is exposed with sub-region. With the control of DSP, the light intensity is decreased to minimum in the glare regions, and the light intensity is negative feedback modulated based on PID theory in other regions. So that more details of the object will be imaging on CCD and the glare protection of monitoring system is achieved. In experiments, the feedback is controlled by the embedded system based on TI DM642. Experiments shows: this feedback modulation method not only reduces the glare vision to improve image quality, but also enhances the dynamic range of image. The high-quality and high dynamic range image is real-time captured at 30hz. The modulation depth of LCoS determines how strong the glare can be removed.
NASA Astrophysics Data System (ADS)
Whitehouse, M.
2016-01-01
Pleiades Visions (2012) is my new musical composition for organ that takes inspiration from traditional lore and music associated with the Pleiades (Seven Sisters) star cluster from Australian Aboriginal, Native American, and Native Hawaiian cultures. It is based on my doctoral dissertation research incorporating techniques from the fields of ethnomusicology and cultural astronomy; this research likely represents a new area of inquiry for both fields. This large-scale work employs the organ's vast sonic resources to evoke the majesty of the night sky and the expansive landscapes of the homelands of the above-mentioned peoples. Other important themes in Pleiades Visions are those of place, origins, cosmology, and the creation of the world.
Veilleux, Carrie C; Cummings, Molly E
2012-12-01
Although variation in the color of light in terrestrial diurnal and twilight environments has been well documented, relatively little work has examined the color of light in nocturnal habitats. Understanding the range and sources of variation in nocturnal light environments has important implications for nocturnal vision, particularly following recent discoveries of nocturnal color vision. In this study, we measured nocturnal irradiance in a dry forest/woodland and a rainforest in Madagascar over 34 nights. We found that a simple linear model including the additive effects of lunar altitude, lunar phase and canopy openness successfully predicted total irradiance flux measurements across 242 clear sky measurements (r=0.85, P<0.0001). However, the relationship between these variables and spectral irradiance was more complex, as interactions between lunar altitude, lunar phase and canopy openness were also important predictors of spectral variation. Further, in contrast to diurnal conditions, nocturnal forests and woodlands share a yellow-green-dominant light environment with peak flux at 560 nm. To explore how nocturnal light environments influence nocturnal vision, we compared photoreceptor spectral tuning, habitat preference and diet in 32 nocturnal mammals. In many species, long-wavelength-sensitive cone spectral sensitivity matched the peak flux present in nocturnal forests and woodlands, suggesting a possible adaptation to maximize photon absorption at night. Further, controlling for phylogeny, we found that fruit/flower consumption significantly predicted short-wavelength-sensitive cone spectral tuning in nocturnal mammals (P=0.002). These results suggest that variation in nocturnal light environments and species ecology together influence cone spectral tuning and color vision in nocturnal mammals.
33 CFR 334.390 - Atlantic Ocean south of entrance to Chesapeake Bay; firing range.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fleet Combat Center, Atlantic, Dam Neck, Virginia Beach, Virginia. After darkness, night vision systems... firing on the range during periods of low visibility which would prevent the recognition of a vessel (to...
33 CFR 334.390 - Atlantic Ocean south of entrance to Chesapeake Bay; firing range.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fleet Combat Center, Atlantic, Dam Neck, Virginia Beach, Virginia. After darkness, night vision systems... firing on the range during periods of low visibility which would prevent the recognition of a vessel (to...
33 CFR 334.390 - Atlantic Ocean south of entrance to Chesapeake Bay; firing range.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fleet Combat Center, Atlantic, Dam Neck, Virginia Beach, Virginia. After darkness, night vision systems... firing on the range during periods of low visibility which would prevent the recognition of a vessel (to...
33 CFR 334.390 - Atlantic Ocean south of entrance to Chesapeake Bay; firing range.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fleet Combat Center, Atlantic, Dam Neck, Virginia Beach, Virginia. After darkness, night vision systems... firing on the range during periods of low visibility which would prevent the recognition of a vessel (to...
33 CFR 334.390 - Atlantic Ocean south of entrance to Chesapeake Bay; firing range.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fleet Combat Center, Atlantic, Dam Neck, Virginia Beach, Virginia. After darkness, night vision systems... firing on the range during periods of low visibility which would prevent the recognition of a vessel (to...
The hazard of spatial disorientation during helicopter flight using night vision devices.
Braithwaite, M G; Douglass, P K; Durnford, S J; Lucas, G
1998-11-01
Night Vision Devices (NVDs) provide an enormous advantage to the operational effectiveness of military helicopter flying by permitting flight throughout the night. However, compared with daytime flight, many of the depth perception and orientational cues are severely degraded. These degraded cues predispose aviators to spatial disorientation (SD), which is a serious drawback of these devices. As part of an overall analysis of Army helicopter accidents to assess the impact of SD on military flying, we scrutinized the class A-C mishap reports involving night-aided flight from 1987 to 1995. The accidents were classified according to the role of SD by three independent assessors, with the SD group further analyzed to determine associated factors and possible countermeasures. Almost 43% of all SD-related accidents in this series occurred during flight using NVDs, whereas only 13% of non-SD accidents involved NVDs. An examination of the SD accident rates per 100,000 flying hours revealed a significant difference between the rate for day flying and the rate for flight using NVDs (mean rate for daytime flight = 1.66, mean rate for NVD flight = 9.00, p < 0.001). The most important factors associated with these accidents were related to equipment limitations, distraction from the task, and training or procedural inadequacies. SD remains an important source of attrition of Army aircraft. The more than fivefold increase in risk associated with NVD flight is of serious concern. The associated factors and suggested countermeasures should be urgently addressed.
Impact of dry eye syndrome on vision-related quality of life.
Miljanović, Biljana; Dana, Reza; Sullivan, David A; Schaumberg, Debra A
2007-03-01
To evaluate the impact of dry eye syndrome (DES) on vision-associated quality of life. Cross-sectional study. We identified 450 participants in the Women's Health Study (WHS) and 240 participants in the Physicians' Health Study (PHS) and sent a supplementary questionnaire asking how much their everyday activities were limited by symptoms of dry eye and to what degree problems with their eyes limited them in reading, driving, working at the computer, their professional activity, and watching television. By design, one-third of study subjects had clinically diagnosed DES or severe symptoms and two-thirds did not. We used logistic regression to examine relationships of DES with reported problems with everyday activities in each cohort and pooled estimates using meta-analysis methods. Of the participants invited, 85% completed the supplementary questionnaire, including 135 WHS and 55 PHS participants with DES, and 250 WHS and 149 PHS participants without DES. Controlling for age, diabetes, hypertension, and other factors, those with DES were more likely to report problems with reading ([odds ratio] OR = 3.64, 95% [confidence interval] CI 2.45 to 5.40, P < .0001); carrying out professional work (OR = 3.49, 95% CI 1.72 to 7.09, P= 0.001); using a computer (OR = 3.37, 95% CI 2.11 to 5.38, P < .0001); watching television (OR = 2.84, 95% CI 1.05 to 7.74, P = .04); driving during the day (OR = 2.80, 95% CI 1.58 to 4.96, P < .0001); and driving at night (OR = 2.20, 95% CI 1.48 to 3.28, P < .0001). DES is associated with a measurable adverse impact on several common and important tasks of daily living, further implicating this condition as an important public health problem deserving increased attention and resources.
ERIC Educational Resources Information Center
Kelly, William E.
2005-01-01
This study explored the relationship between night-sky watching and self-reported cognitive variables: need for cognition and social problem-solving. University students (N = 140) completed the Noctcaelador Inventory, the Need for Cognition Scale, and the Social Problem Solving Inventory. The results indicated that an interest in the night-sky was…
Bower, Kraig S; Burka, Jenna M; Subramanian, Prem S; Stutzman, Richard D; Mines, Michael J; Rabin, Jeff C
2006-06-01
To investigate the effect of laser refractive surgery on night weapons firing. Firing range performance was measured at baseline and postoperatively following photorefractive keratectomy and laser in situ keratomileusis. Subjects fired the M-16A2 rifle with night vision goggles (NVG) at starlight, and with iron sight (simulated dusk). Scores, before and after surgery, were compared for both conditions. No subject was able to acquire the target using iron sight without correction before surgery. After surgery, the scores without correction (95.9 +/- 4.7) matched the preoperative scores with correction (94.3 +/- 4.0; p = 0.324). Uncorrected NVG scores after surgery (96.4 +/- 3.1) exceeded the corrected scores before surgery (91.4 +/- 10.2), but this trend was not statistically significant (p = 0.063). Night weapon firing with both the iron sight and the NVG sight improved after surgery. This study supports the operational benefits of refractive surgery in the military.
NASA Astrophysics Data System (ADS)
Aoki, Hirooki; Aoki, Hiroichi; Nakajima, Masato
Measurement of biological information appears to be an effective method to obtain an understanding of health conditions measures to maintain and improve the health of elderly people. However, every conventional bioinstrumentation technique imposes a sense of restraint that results in aversion against measurements that would last over consecutive days. To solve this problem, we propose a system for monitoring the respiration of sleepers, and it uses a fiber grating vision sensor, which is a type of optical range finder, to achieve non-contact and unrestrained monitoring. The signals obtained by the system include the respiration rate, shifts of the ventilation, and the body movement interval of the sleeper. The information enables to investigate the stability of the sleeper throughout the night. We examined the measuring accuracy, validity, and effectiveness of our proposed system. And all-night monitoring performed at elderly care facility revealed that respiratory disturbances during sleep occurred in many of the residents and that sleep apnea is a common syndrome, especially among residents who have senile dementia or have had a stroke. We were able to carry out the all-night monitoring with this system for a total of about 370 times, according to our schedule, without experiencing any failure, accident, or interruption. Our proposed system is highly effective for monitoring elderly dementia patients who are likely to become uncooperative during measurement with existing monitoring methods that use certain amounts of restraint.
Evaluation of Night Vision Devices for Image Fusion Studies
2004-12-01
July 2004. http://www.sensorsmag.com/articles/0400/34/main.shtml Task, Harry L., Hartman, Richard T., Marasco , Peter L., Methods for Measuring...Press, Bellingham, Washington, 1998. Burt, Peter J. & Kolczynski, Raymond J., David Sarnoff Research Center, Enhanced Image Capture through Fusion
78 FR 22527 - Army Science Board Request for Information on Technology and Core Competencies
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-16
...); Edgewood Chemical Biological Command (ECBC); Natick Soldier Research, Development & Engineering Center...; C4ISR; Night Vision; Chemical/Biological Warfare; and Soldier Systems. The study will focus on...); Armament Research, Development & Engineering Center (ARDEC); Aviation & Missile Research, Development...
Oxygenation state and twilight vision at 2438 m.
Connolly, Desmond M
2011-01-01
Under twilight viewing conditions, hypoxia, equivalent to breathing air at 3048 m (10,000 ft), compromises low contrast acuity, dynamic contrast sensitivity, and chromatic sensitivity. Selected past experiments have been repeated under milder hypoxia, equivalent to altitude exposure below 2438 m (8000 ft), to further define the influence of oxygenation state on mesopic vision. To assess photopic and mesopic visual function, 12 subjects each undertook three experiments using the Contrast Acuity Assessment test, the Frequency Doubling Perimeter, and the Color Assessment and Diagnosis (CAD) test. Experiments were conducted near sea level breathing 15.2% oxygen (balance nitrogen) and 100% oxygen, representing mild hypobaric hypoxia at 2438 m (8000 ft) and the benefit of supplementary oxygen, respectively. Oxygenation state was a statistically significant determinant of visual performance on all three visual parameters at mesopic, but not photopic, luminance. Mesopic sensitivity was greater with supplementary oxygen, but the magnitude of each hypoxic decrement was slight. Hypoxia elevated mesopic contrast acuity thresholds by approximately 4%; decreased mesopic dynamic contrast sensitivity by approximately 2 dB; and extended mean color ellipse axis length by approximately one CAD unit at mesopic luminance (that is, hypoxia decreased chromatic sensitivity). The results indicate that twilight vision may be susceptible to conditions of altered oxygenation at upper-to-mid mesopic luminance with relevance to contemporary night flying, including using night vision devices. Supplementary oxygen should be considered when optimal visual performance is mission-critical during flight above 2438 m (8000 ft) in dim light.
Vision Problems in Homeless Children.
Smith, Natalie L; Smith, Thomas J; DeSantis, Diana; Suhocki, Marissa; Fenske, Danielle
2015-08-01
Vision problems in homeless children can decrease educational achievement and quality of life. To estimate the prevalence and specific diagnoses of vision problems in children in an urban homeless shelter. A prospective series of 107 homeless children and teenagers who underwent screening with a vision questionnaire, eye chart screening (if mature enough) and if vision problem suspected, evaluation by a pediatric ophthalmologist. Glasses and other therapeutic interventions were provided if necessary. The prevalence of vision problems in this population was 25%. Common diagnoses included astigmatism, amblyopia, anisometropia, myopia, and hyperopia. Glasses were required and provided for 24 children (22%). Vision problems in homeless children are common and frequently correctable with ophthalmic intervention. Evaluation by pediatric ophthalmologist is crucial for accurate diagnoses and treatment. Our system of screening and evaluation is feasible, efficacious, and reproducible in other homeless care situations.
AN INVESTIGATION OF VISION PROBLEMS AND THE VISION CARE SYSTEM IN RURAL CHINA.
Bai, Yunli; Yi, Hongmei; Zhang, Linxiu; Shi, Yaojiang; Ma, Xiaochen; Congdon, Nathan; Zhou, Zhongqiang; Boswell, Matthew; Rozelle, Scott
2014-11-01
This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.
Neck muscle activity in fighter pilots wearing night-vision equipment during simulated flight.
Ang, Björn O; Kristoffersson, Mats
2013-02-01
Night-vision goggles (NVG) in jet fighter aircraft appear to increase the risk of neck strain due to increased neck loading. The present aim was, therefore, to evaluate the effect on neck-muscle activity and subjective ratings of head-worn night-vision (NV) equipment in controlled simulated flights. Five experienced fighter pilots twice flew a standardized 2.5-h program in a dynamic flight simulator; one session with NVG and one with standard helmet mockup (control session). Each session commenced with a 1-h simulation at 1 Gz followed by a 1.5-h dynamic flight with repeated Gz profiles varying between 3 and 7 Gz and including aerial combat maneuvers (ACM) at 3-5 Gz. Large head-and-neck movements under high G conditions were avoided. Surface electromyographic (EMG) data was simultaneously measured bilaterally from anterior neck, upper and lower posterior neck, and upper shoulder muscles. EMG activity was normalized as the percentage of pretest maximal voluntary contraction (%MVC). Head-worn equipment (helmet comfort, balance, neck mobility, and discomfort) was rated subjectively immediately after flight. A trend emerged toward greater overall neck muscle activity in NV flight during sustained ACM episodes (10% vs. 8% MVC for the control session), but with no such effects for temporary 3-7 Gz profiles. Postflight ratings for NV sessions emerged as "unsatisfactory" for helmet comfort/neck discomfort. However, this was not significant compared to the control session. Helmet mounted NV equipment caused greater neck muscle activity during sustained combat maneuvers, indicating increased muscle strain due to increased neck loading. In addition, postflight ratings indicated neck discomfort after NV sessions, although not clearly increased compared to flying with standard helmet mockup.
Scorpion Hybrid Optical-based Inertial Tracker (HObIT) test results
NASA Astrophysics Data System (ADS)
Atac, Robert; Spink, Scott; Calloway, Tom; Foxlin, Eric
2014-06-01
High fidelity night-vision training has become important for many of the simulation systems being procured today. The end-users of these simulation-training systems prefer using their actual night-vision goggle (NVG) headsets. This requires that the visual display system stimulate the NVGs in a realistic way. Historically NVG stimulation was done with cathode-ray tube (CRT) projectors. However, this technology became obsolete and in recent years training simulators do NVG stimulation with laser, LCoS and DLP projectors. The LCoS and DLP projection technologies have emerged as the preferred approach for the stimulation of NVGs. Both LCoS and DLP technologies have advantages and disadvantages for stimulating NVGs. LCoS projectors can have more than 5-10 times the contrast capability of DLP projectors. The larger the difference between the projected black level and the brightest object in a scene, the better the NVG stimulation effects can be. This is an advantage of LCoS technology, especially when the proper NVG wavelengths are used. Single-chip DLP projectors, even though they have much reduced contrast compared to LCoS projectors, can use LED illuminators in a sequential red-green-blue fashion to create a projected image. It is straightforward to add an extra infrared (NVG wavelength) LED into this sequential chain of LED illumination. The content of this NVG channel can be independent of the visible scene, which allows effects to be added that can compensate for the lack of contrast inherent in a DLP device. This paper will expand on the differences between LCoS and DLP projectors for stimulating NVGs and summarize the benefits of both in night-vision simulation training systems.
Night vision imaging system design, integration and verification in spacecraft vacuum thermal test
NASA Astrophysics Data System (ADS)
Shang, Yonghong; Wang, Jing; Gong, Zhe; Li, Xiyuan; Pei, Yifei; Bai, Tingzhu; Zhen, Haijing
2015-08-01
The purposes of spacecraft vacuum thermal test are to characterize the thermal control systems of the spacecraft and its component in its cruise configuration and to allow for early retirement of risks associated with mission-specific and novel thermal designs. The orbit heat flux is simulating by infrared lamp, infrared cage or electric heater. As infrared cage and electric heater do not emit visible light, or infrared lamp just emits limited visible light test, ordinary camera could not operate due to low luminous density in test. Moreover, some special instruments such as satellite-borne infrared sensors are sensitive to visible light and it couldn't compensate light during test. For improving the ability of fine monitoring on spacecraft and exhibition of test progress in condition of ultra-low luminous density, night vision imaging system is designed and integrated by BISEE. System is consist of high-gain image intensifier ICCD camera, assistant luminance system, glare protect system, thermal control system and computer control system. The multi-frame accumulation target detect technology is adopted for high quality image recognition in captive test. Optical system, mechanical system and electrical system are designed and integrated highly adaptable to vacuum environment. Molybdenum/Polyimide thin film electrical heater controls the temperature of ICCD camera. The results of performance validation test shown that system could operate under vacuum thermal environment of 1.33×10-3Pa vacuum degree and 100K shroud temperature in the space environment simulator, and its working temperature is maintains at 5° during two-day test. The night vision imaging system could obtain video quality of 60lp/mm resolving power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shastry, B.S.; Trese, M.T.
1995-11-20
X-linked retinitis pigmentosa (XLRP) is the most severe form of the inherited forms of retinitis pigmentosa and is clinically variable and genetically heterogeneous. It affects one in 20,000 live births. The affected individuals manifest degeneration of the peripheral retina during the first two decades of life on the basis of night blindness. Central vision usually is preserved until age 50, when the disease advances, affecting central vision and ultimately leading to complete loss of sight. Linkage analysis has shown two loci with a possibility of a third locus on the human X chromosome. The genetic abnormality that causes XLRP ismore » not known at present. Here we describe a large kindred which manifests central loss of field with the preservation of peripheral vision. 5 refs., 1 fig.« less
Silva, Graciela E.; Goodwin, James L.; Parthasarathy, Sairam; Sherrill, Duane L.; Vana, Kimberly D.; Drescher, Amy A.; Quan, Stuart F.
2011-01-01
Study Objective: To determine the impact of lower amounts of childhood sleep assessed by polysomnogram on development of obesity, being anxious or depressed, or having learning problems 5 years later. Design: Prospective cohort. Participants: Subjects were 304 community participants from the Tucson Children's Assessment of Sleep Apnea study, aged 6–12 years old at baseline. Measurements and Results: Children were classified according to baseline sleep as those who slept ≥ 9 h/night, those who slept > 7.5 to < 9 h/night, and those who slept ≤ 7.5 h/night. Odds of overweight/obese (≥ 85th BMI percentile), obese (≥ 95th BMI percentile), anxious or depressed, and learning problems at follow-up were assessed according to baseline sleep categories. Children who slept ≤ 7.5 h/night had higher odds of being obese (OR = 3.3, P < 0.05) at follow-up than children who slept ≥ 9 h/night. Borderline significance for overweight/obese (OR = 2.2, P < 0.1), anxious or depressed (OR = 3.3, P < 0.1), and having learning problems (OR = 11.1, P < 0.1) were seen for children who slept ≤ 7.5 h/night as compared to those who slept ≥ 9 h/night. A mean increase in BMI of 1.7 kg/m2 (P = 0.01) over the 5 years of follow-up was seen for children who slept ≤ 7.5 h/night compared to those who slept ≥ 9 h/night. These relationships did not differ between Hispanic and Caucasian children. Conclusions: Children with reduced amounts of sleep (≤ 7.5 h/night) had an increased risk for higher body weight in early adolescence. Similarly, children who slept ≤ 7.5 h/night had higher risk of being anxious or depressed or having learning problems in early adolescence. Citation: Silva GE; Goodwin JL; Parthasarathy S; Sherrill DL; Vana KD; Drescher AA; Quan SF. Longitudinal association between short sleep, body weight, and emotional and learning problems in Hispanic and Caucasian children. SLEEP 2011;34(9):1197-1205. PMID:21886357
Special Technology Area Review on Micro-Opto-Electro-Mechanical-Systems (MOEMS)
1997-12-01
Optical Interference in Night Vision Systems "* DMD Assisted Intelligent Manufacturing of ................................................... SRI...CONCEPT ......................................... p. 8 FIGURE 3(a): DMD LIGHT SWITCHES...p. 9 FIGURE 3(b): SEM PHOTOMICROGRAPHS OF DMD CHIPS ........................................ p. 9 FIGURE 4: MULTI-USER MEMS PROJECTS (MUMPS
Code of Federal Regulations, 2014 CFR
2014-07-01
... Combat Center. After darkness, night vision systems will be utilized by lookouts to aid in locating vessels transiting the area. (5) There shall be no firing on any ranges during the periods of low...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Combat Center. After darkness, night vision systems will be utilized by lookouts to aid in locating vessels transiting the area. (5) There shall be no firing on any ranges during the periods of low...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Combat Center. After darkness, night vision systems will be utilized by lookouts to aid in locating vessels transiting the area. (5) There shall be no firing on any ranges during the periods of low...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Combat Center. After darkness, night vision systems will be utilized by lookouts to aid in locating vessels transiting the area. (5) There shall be no firing on any ranges during the periods of low...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Combat Center. After darkness, night vision systems will be utilized by lookouts to aid in locating vessels transiting the area. (5) There shall be no firing on any ranges during the periods of low...
Owczarek, Grzegorz; Gralewicz, Grzegorz; Skuza, Natalia; Jurowski, Piotr
2016-01-01
In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular lenses with or without yellow chromophore on functional vision in everyday environmental conditions was analysed.
1991-12-01
integration. Threc papers considered the ergonomics of helmet design and the snugness of fit to the head and the integration of new helmet mounted devices...with existing equipment. Two papers considered the effects of novel helmet designs on the pilot’s ability to control head position and avoid fatigue. Two...the nature of information displayed, including data fused froml multiple sources and design of abstract symbologics that presernt paramcecis of fight
NASA Astrophysics Data System (ADS)
Folaron, Michelle; Deacutis, Martin; Hegarty, Jennifer; Vollmerhausen, Richard; Schroeder, John; Colby, Frank P.
2007-04-01
US Navy and Marine Corps pilots receive Night Vision Goggle (NVG) training as part of their overall training to maintain the superiority of our forces. This training must incorporate realistic targets; backgrounds; and representative atmospheric and weather effects they may encounter under operational conditions. An approach for pilot NVG training is to use the Night Imaging and Threat Evaluation Laboratory (NITE Lab) concept. The NITE Labs utilize a 10' by 10' static terrain model equipped with both natural and cultural lighting that are used to demonstrate various illumination conditions, and visual phenomena which might be experienced when utilizing night vision goggles. With this technology, the military can safely, systematically, and reliably expose pilots to the large number of potentially dangerous environmental conditions that will be experienced in their NVG training flights. A previous SPIE presentation described our work for NAVAIR to add realistic atmospheric and weather effects to the NVG NITE Lab training facility using the NVG - WDT(Weather Depiction Technology) system (Colby, et al.). NVG -WDT consist of a high end multiprocessor server with weather simulation software, and several fixed and goggle mounted Heads Up Displays (HUDs). Atmospheric and weather effects are simulated using state-of-the-art computer codes such as the WRF (Weather Research μ Forecasting) model; and the US Air Force Research Laboratory MODTRAN radiative transport model. Imagery for a variety of natural and man-made obscurations (e.g. rain, clouds, snow, dust, smoke, chemical releases) are being calculated and injected into the scene observed through the NVG via the fixed and goggle mounted HUDs. This paper expands on the work described in the previous presentation and will describe the 3D Virtual/Augmented Reality Scene - Weather - Atmosphere - Target Simulation part of the NVG - WDT. The 3D virtual reality software is a complete simulation system to generate realistic target - background scenes and display the results in a DirectX environment. This paper will describe our approach and show a brief demonstration of the software capabilities. The work is supported by the SBIR program under contract N61339-06-C-0113.
Alternatives to Pyrotechnic Distress Signals; Laboratory and Field Studies
2015-03-01
using night vision imaging systems (NVIS) with “minus-blue” filtering,” the project recommends additional research and testing leading to the inclusion...18 5.2.3 Background Images ...Example of image capture from radiant imaging colorimeter. ....................................................... 16 Figure 10. Laboratory setup
Properties of light reflected from road signs in active imaging.
Halstuch, Aviran; Yitzhaky, Yitzhak
2008-08-01
Night vision systems in vehicles are a new emerging technology. A crucial problem in active (laser-based) systems is distortion of images by saturation and blooming due to strong retroreflections from road signs. We quantify this phenomenon. We measure the Mueller matrices and the polarization state of the reflected light from three different types of road sign commonly used. Measurements of the reflected intensity are also taken with respect to the angle of reflection. We find that different types of sign have different reflection properties. It is concluded that the optimal solution for attenuating the retroreflected intensity is using a linear polarized light source and a linear polarizer with perpendicular orientation (with regard to the source) at the detector. Unfortunately, while this solution performs well for two types of road sign, it is less efficient for the third sign type.
Detection of Special Operations Forces Using Night Vision Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, C.M.
2001-10-22
Night vision devices, such image intensifiers and infrared imagers, are readily available to a host of nations, organizations, and individuals through international commerce. Once the trademark of special operations units, these devices are widely advertised to ''turn night into day''. In truth, they cannot accomplish this formidable task, but they do offer impressive enhancement of vision in limited light scenarios through electronically generated images. Image intensifiers and infrared imagers are both electronic devices for enhancing vision in the dark. However, each is based upon a totally different physical phenomenon. Image intensifiers amplify the available light energy whereas infrared imagers detectmore » the thermal energy radiated from all objects. Because of this, each device operates from energy which is present in a different portion of the electromagnetic spectrum. This leads to differences in the ability of each device to detect and/or identify objects. This report is a compilation of the available information on both state-of-the-art image intensifiers and infrared imagers. Image intensifiers developed in the United States, as well as some foreign made image intensifiers, are discussed. Image intensifiers are categorized according to their spectral response and sensitivity using the nomenclature of GEN I, GEN II, and GEN III. As the first generation of image intensifiers, GEN I, were large and of limited performance, this report will deal with only GEN II and GEN III equipment. Infrared imagers are generally categorized according to their spectral response, sensor materials, and related sensor operating temperature using the nomenclature Medium Wavelength Infrared (MWIR) Cooled and Long Wavelength Infrared (LWIR) Uncooled. MWIR Cooled refers to infrared imagers which operate in the 3 to 5 {micro}m wavelength electromagnetic spectral region and require either mechanical or thermoelectric coolers to keep the sensors operating at 77 K. LWIR Uncooled refers to infrared imagers which operate in the 8 to 12 {micro}m wavelength electromagnetic spectral region and do not require cooling below room temperature. Both commercial and military infrared sensors of these two types are discussed.« less
Dynamic programming and graph algorithms in computer vision.
Felzenszwalb, Pedro F; Zabih, Ramin
2011-04-01
Optimization is a powerful paradigm for expressing and solving problems in a wide range of areas, and has been successfully applied to many vision problems. Discrete optimization techniques are especially interesting since, by carefully exploiting problem structure, they often provide nontrivial guarantees concerning solution quality. In this paper, we review dynamic programming and graph algorithms, and discuss representative examples of how these discrete optimization techniques have been applied to some classical vision problems. We focus on the low-level vision problem of stereo, the mid-level problem of interactive object segmentation, and the high-level problem of model-based recognition.
An approach to integrate the human vision psychology and perception knowledge into image enhancement
NASA Astrophysics Data System (ADS)
Wang, Hui; Huang, Xifeng; Ping, Jiang
2009-07-01
Image enhancement is very important image preprocessing technology especially when the image is captured in the poor imaging condition or dealing with the high bits image. The benefactor of image enhancement either may be a human observer or a computer vision process performing some kind of higher-level image analysis, such as target detection or scene understanding. One of the main objects of the image enhancement is getting a high dynamic range image and a high contrast degree image for human perception or interpretation. So, it is very necessary to integrate either empirical or statistical human vision psychology and perception knowledge into image enhancement. The human vision psychology and perception claims that humans' perception and response to the intensity fluctuation δu of visual signals are weighted by the background stimulus u, instead of being plainly uniform. There are three main laws: Weber's law, Weber- Fechner's law and Stevens's Law that describe this phenomenon in the psychology and psychophysics. This paper will integrate these three laws of the human vision psychology and perception into a very popular image enhancement algorithm named Adaptive Plateau Equalization (APE). The experiments were done on the high bits star image captured in night scene and the infrared-red image both the static image and the video stream. For the jitter problem in the video stream, this algorithm reduces this problem using the difference between the current frame's plateau value and the previous frame's plateau value to correct the current frame's plateau value. Considering the random noise impacts, the pixel value mapping process is not only depending on the current pixel but the pixels in the window surround the current pixel. The window size is usually 3×3. The process results of this improved algorithms is evaluated by the entropy analysis and visual perception analysis. The experiments' result showed the improved APE algorithms improved the quality of the image, the target and the surrounding assistant targets could be identified easily, and the noise was not amplified much. For the low quality image, these improved algorithms augment the information entropy and improve the image and the video stream aesthetic quality, while for the high quality image they will not debase the quality of the image.
Vision Problems: How Teachers Can Help.
ERIC Educational Resources Information Center
Desrochers, Joyce
1999-01-01
Describes common vision problems in young children such as myopia, strabismus, and amblyopia. Presents suggestions for helping children with vision problems in the early childhood classroom and in outdoor activities. Lists related resources and children's books. (KB)
Optimal design of photoreceptor mosaics: why we do not see color at night.
Manning, Jeremy R; Brainard, David H
2009-01-01
While color vision mediated by rod photoreceptors in dim light is possible (Kelber & Roth, 2006), most animals, including humans, do not see in color at night. This is because their retinas contain only a single class of rod photoreceptors. Many of these same animals have daylight color vision, mediated by multiple classes of cone photoreceptors. We develop a general formulation, based on Bayesian decision theory, to evaluate the efficacy of various retinal photoreceptor mosaics. The formulation evaluates each mosaic under the assumption that its output is processed to optimally estimate the image. It also explicitly takes into account the statistics of the environmental image ensemble. Using the general formulation, we consider the trade-off between monochromatic and dichromatic retinal designs as a function of overall illuminant intensity. We are able to demonstrate a set of assumptions under which the prevalent biological pattern represents optimal processing. These assumptions include an image ensemble characterized by high correlations between image intensities at nearby locations, as well as high correlations between intensities in different wavelength bands. They also include a constraint on receptor photopigment biophysics and/or the information carried by different wavelengths that produces an asymmetry in the signal-to-noise ratio of the output of different receptor classes. Our results thus provide an optimality explanation for the evolution of color vision for daylight conditions and monochromatic vision for nighttime conditions. An additional result from our calculations is that regular spatial interleaving of two receptor classes in a dichromatic retina yields performance superior to that of a retina where receptors of the same class are clumped together.
Small Unmanned Aerial Vehicles; DHS’s Answer to Border Surveillance Requirements
2013-03-01
5 of more than 4000 illegal aliens, including the seizure of more than 15,000 pounds of marijuana .13 In addition to the Predator UAVs being...payload includes two color video cameras, an infrared camera that offers night vision capability and synthetic aperture radar that provides high
75 FR 52790 - Small Business Size Standards: Waiver of the Nonmanufacturer Rule
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... for GEN II and GEN III Image Intensifier Tubes. SUMMARY: The U.S. Small Business Administration (SBA... Image Intensifier Tubes, Product Service Code (PSC) 5855, Night Vision Equipment, Emitted and Reflected... business GEN II and GEN III image intensifier tube manufacturers. If granted, the waiver would allow...
Panoramic Night Vision Goggle Testing For Diagnosis and Repair
2000-01-01
Visual Acuity Visual Acuity [ Marasco & Task, 1999] measures how well a human observer can see high contrast targets at specified light levels through...grid through the PNVG in-board and out-board channels simultaneously and comparing the defects to the size of grid features ( Marasco & Task, 1999). The
78 FR 22848 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-17
... Spare Guidance Sections, 18 AN/AVS-9(V) Night Vision Goggles, H-764G with GEM V Selective Availability... support of a Direct Commercial Sale of new F-15SG aircraft. Also included: containers, spare and repair... Selective Availability Anti-Spoofing Module (SAASM), Common Munitions Built-in-Test Reprogramming Equipment...
Copyright in the Age of Photocopiers, Word Processors, and the Internet
ERIC Educational Resources Information Center
Shaw, Marjorie Hodges; Shaw, Brian B.
2003-01-01
Widespread digital infringement of the copyrighted material now has made security firms, night-vision goggles, and metal detectors common in movie previews. The current national controversy over peer-to-peer file sharing of music highlights the difficult questions facing colleges and universities as they grapple with dramatic technological…
Glare disability and driving safety.
Babizhayev, M A
2003-01-01
Increasing investigation of the visual elements of safe driving environments may be of great benefit to society. Visual disability appears to be only one of many visual factors related to traffic accidents. The purpose of this article was to examine the type of visual impairment mediated by the increased glare sensitivity in adult drivers using the original halometer glare test. In this article, the visual sensory, cognitive and motor functions relevant to driving, their measurement, the epidemiology and prevention of age-associated functional impairments and the relationship of functional impairments to both self-reported driving and the imposition of legal restrictions are reviewed. The problem of night and tunnel driving is the most urgent in relation to the effects of glare from vehicle headlights on motion perception of drivers. The reduced mesopic vision and increased sensitivity to glare are accompanied by an increased risk of nighttime accidents. Elderly drivers and patients with beginning cataract cannot sufficiently fulfill the criteria for night driving ability because of contrast and glare sensitivity. It is indispensable for the parameters mentioned to be carefully measured and for drivers to be informed that night driving ability may be impaired, even if visual acuity is sufficient. It would be advisable for traffic safety if simple tests for contrast and glare sensitivity were implemented for vehicles and/or were regularly added to the requirements for a driver's licence, at least for older drivers. The age, functional status and test result limits should be defined to avoid a risk factor in traffic. Copyright 2003 S. Karger AG, Basel
Visual analysis of orthokeratology on myopia reduction for aviators
NASA Astrophysics Data System (ADS)
Mitsui, Iwane
2005-04-01
Ortho-K was indicated for sixty eyes of thirty aviators, twenty-one pilots and nine flight attendants, with age of 34.5 on the average. Uncorrected visual acuity (UCVA) was originally 20/30 or worse in all cases. The mean spherical equivalent (SE) was -3.69 Diopters (D). The same ophthalmologist designed full costumed reverse geometry Advanced Orthokeratology lenses for each patient. All the patients were followed at least two years wearing of Advanced Ortho-K lenses. The follow up examinations on auto-refraction, auto-keratometry, uncorrected and corrected visual acuity, intra-ocular pressure, corneal endothelial cells, corneal thickness and curve, and corneal shape were performed in the morning, 10am to 12am. 94% of the patients improved in UCVA up to 20/20 or better, 87% of them improved up to 20/15 or better, and 67% of them improved up to 20/10. The mean SEs improved to -1.90+/-1.00D during six months, -1.49+/-1.03D during one year, and -0.73+/-0.94D during two years. Astigmatism slightly increased by 0.38D on the average, however, it did not cause any serious problems for aviation tasks even during night. Intraocular pressure did not increase and corneal endothelial cells did not decrease. Other ophthalmologic examinations showed normal conditions and any complications were not observed throughout the period. Advanced Ortho-K was evaluated to be safe and effective enough for also aviators with myopia. It can be recommended one of the options of reduction of myopia for aviators. Evaluations on night vision and night glare are planned for further studies.
Tests of a theory for diel activity and habitat selection
Steven F. Railsback; Bret C. Harvey; John W. Hayse; Kirk E. Lagory
2005-01-01
For many animals, selecting whether to forage during day or night is a critical fitness problem: at night, predation risks are lower but feeding is less efficient. Habitat selection is a closely related problem: the best location for nocturnal foraging could be too risky during daytime, and habitat that is safe and profitable in daytime may be unprofitable at night. We...
Dynamic Programming and Graph Algorithms in Computer Vision*
Felzenszwalb, Pedro F.; Zabih, Ramin
2013-01-01
Optimization is a powerful paradigm for expressing and solving problems in a wide range of areas, and has been successfully applied to many vision problems. Discrete optimization techniques are especially interesting, since by carefully exploiting problem structure they often provide non-trivial guarantees concerning solution quality. In this paper we briefly review dynamic programming and graph algorithms, and discuss representative examples of how these discrete optimization techniques have been applied to some classical vision problems. We focus on the low-level vision problem of stereo; the mid-level problem of interactive object segmentation; and the high-level problem of model-based recognition. PMID:20660950
Sleep Habits and Sleep Problems in Healthy Preschoolers.
Murthy, C L Srinivasa; Bharti, Bhavneet; Malhi, Prahbhjot; Khadwal, Alka
2015-07-01
To describe the sleep patterns and problems in children aged between 12 and 36 mo of age. This cross sectional survey was collected over a span of 1 y in Advanced Pediatric Centre, PGIMER, Chandigarh and crèches of Chandigarh. Children in the age group of 12 to 36 mo were included in study. Children with chronic illness, developmental delay, seizure disorder and lack of consent were excluded. A total of 368 children were enrolled. Main outcome measures were sleep duration over 1 to 3 y of life; sleep behavior at onset, during and waking of sleep and parent reported sleep problems and their predictors. The average duration of sleep was 12.5 h (S.D = 1.9). The mean total sleep duration and mean day time sleep duration decreased, while mean night time sleep increased as the age advanced from 12 to 36 mo. Following were the frequency of sleep habits seen in the index study; bed time routine was seen only in 68(18.5 %), a regular bed time ritual was seen in 281(76.4 %), 329(89.4 %) children frequently required 0-20 min time to fall asleep, 11(3 %) parents used sleep inducing drugs. Night waking (1 to 3 times a night) was seen in 297(80.7 %) and its frequency declined with age. Parent reported sleep problems were seen in 12.8 % (47/368). Lack of co-sleeping and night waking were considered as strongest predictors of parent reported sleep problems. Toddlers' sleep duration, night waking behavior, and day time naps decrease as the age progress while night time sleep duration increases with age. Lack of co-sleeping and night waking are considered as strongest predictors of parent reported sleep problems.
Night-waking and behavior in preschoolers: a developmental trajectory approach.
Reynaud, Eve; Forhan, Anne; Heude, Barbara; Charles, Marie-Aline; Plancoulaine, Sabine
2018-03-01
The aim was to study, with a developmental approach, the longitudinal association between night-waking from age 2 to 5-6 years and behavior at age 5-6 years. Within the French birth cohort study Etude sur les Déterminants pré et post natals du développement et de la santé de l'ENfant (EDEN), repeated measures of children's night-waking were collected at age 2, 3 and 5-6 through parental questionnaires and were used to model night-waking trajectories. Behavior was assessed with the "Strengths and Difficulties Questionnaire," which provides five subscales measuring a child's conduct problems, emotional symptoms, peer relation problems, antisocial behavior, and hyperactivity/attention problems. The behavioral subscales were dichotomized at the tenth percentile. Multivariable logistic regressions, adjusted for parents' socio-economic factors, parental characteristics, and children's characteristics and sleep habits allowed us to study, in 1143 children, the association between night-waking trajectories from 2 to 5-6 years and behavior at age 5-6 years. The "2 to 5-6 rare night-waking" trajectory represented 78% of the included population (n = 896), and the "2 to 5-6 common night-waking" 22% (n = 247%). Children belonging to the "2 to 5-6 common night-waking trajectory" had, at age 5-6, increased risk of presenting emotional symptoms (odds ratio [OR] = 2.17, 95% CI = 1.27-3.70, p = 0.004), conduct problems (OR = 1.63, 95% CI = 1.00-2.65, p = 0.050), and hyperactivity/attention problems (OR = 1.61, 95% CI = 1.00-2.57, p = 0.049). After adjusting for baseline behavior at age two years, only the association with emotional symptoms remained significant (OR = 2.02, 95% CI = 1.15-3.55, p = 0.015). Results did not differ according to sex. Results suggest that the persistence of night-waking difficulties in early years is positively associated with emotional symptoms, hyperactivity/inattention, and conduct problems. Copyright © 2017 Elsevier B.V. All rights reserved.
Eyes for Learning: Preventing and Curing Vision-Related Learning Problems
ERIC Educational Resources Information Center
Orfield, Antonia
2007-01-01
Dr. Orfield's highly readable guide on vision development presents ground-breaking solutions to common learning problems and is supported by substantial data. This holistic common sense--that most people do not know--is not just about vision but also how vision is interrelated with learning. It teaches how to care for a child's vision as well as…
Applying Rhetorical Genre Studies to a Stand-Alone Online Professional Writing Course
ERIC Educational Resources Information Center
Adams, Heather Brook; Jenkins, Patricia
2015-01-01
This program profile explains and illustrates a pedagogical application of Rhetorical Genre Studies (RGS) to a one-semester, upper-division online Professional Writing course. We explain our use of a heuristic, which we liken to "night-vision goggles," that enables students to systematically analyze field data that they gather from a…
The USEPA's SITE Program conducted a demonstration of the Enhanced In Situ Bioremediation Process at the ITT Industries Night Vision Facility in Roanoke, VA. The biostimulation process, developed by the USEOE and licensed to Earth Tech, Inc., involves injecting a mixture of air, ...
Preparation of Ferroelectric Samples for Electrical and Radiation Characterization Studies
1991-12-01
Nuclear Agency Attn Technology Dir Attn RAEE , LTC A. Constantine 5001 Eisenhower Ave Attn RAEE , MAJ G. Kweder Alexandria, VA 22333-0001 Attn RAEE , L...Palkuti Attn RAEE , LCDR L. Cohn Director Attn TITL, Technical Library Div Night Vision & Electro-Optics Lab.. LABCOM 680’ Telegraph RD Attn AMSEL-TMS
Methods for Measuring Characteristics of Night Vision Goggles
1993-10-01
TA 18 6. AUTHOR(S) WU 07 Harry L. Task Peter L. Marasco Richard T. Hartman, Capt Annette R. Zobel 7. PEP.FORMING...DTIC S SELECTE T Harry L. Task 3 MR 16 1994 R Richard T. Hartman 0 Peter L. Mardsco F N CREW SYSTEMS DIRECTORATE G HUMAN ENGINEERING DIVX[SIONWRIGHT-PAT
Rifle Marksmanship Diagnostic and Training Guide
2011-05-01
there any techniques you use to help prepare Soldiers to transition to firing with aiming lights (PEQ-2 or PAQ -4) and night vision goggles (ARM 1)? If...firing skills with the PAQ -4? A‐5 15. Are there any other diagnostic techniques you use that we haven’t discussed? a. Think back on your
All-CMOS night vision viewer with integrated microdisplay
NASA Astrophysics Data System (ADS)
Goosen, Marius E.; Venter, Petrus J.; du Plessis, Monuko; Faure, Nicolaas M.; Janse van Rensburg, Christo; Rademeyer, Pieter
2014-02-01
The unrivalled integration potential of CMOS has made it the dominant technology for digital integrated circuits. With the advent of visible light emission from silicon through hot carrier electroluminescence, several applications arose, all of which rely upon the advantages of mature CMOS technologies for a competitive edge in a very active and attractive market. In this paper we present a low-cost night vision viewer which employs only standard CMOS technologies. A commercial CMOS imager is utilized for near infrared image capturing with a 128x96 pixel all-CMOS microdisplay implemented to convey the image to the user. The display is implemented in a standard 0.35 μm CMOS process, with no process alterations or post processing. The display features a 25 μm pixel pitch and a 3.2 mm x 2.4 mm active area, which through magnification presents the virtual image to the user equivalent of a 19-inch display viewed from a distance of 3 meters. This work represents the first application of a CMOS microdisplay in a low-cost consumer product.
A robust color image fusion for low light level and infrared images
NASA Astrophysics Data System (ADS)
Liu, Chao; Zhang, Xiao-hui; Hu, Qing-ping; Chen, Yong-kang
2016-09-01
The low light level and infrared color fusion technology has achieved great success in the field of night vision, the technology is designed to make the hot target of fused image pop out with intenser colors, represent the background details with a nearest color appearance to nature, and improve the ability in target discovery, detection and identification. The low light level images have great noise under low illumination, and that the existing color fusion methods are easily to be influenced by low light level channel noise. To be explicit, when the low light level image noise is very large, the quality of the fused image decreases significantly, and even targets in infrared image would be submerged by the noise. This paper proposes an adaptive color night vision technology, the noise evaluation parameters of low light level image is introduced into fusion process, which improve the robustness of the color fusion. The color fuse results are still very good in low-light situations, which shows that this method can effectively improve the quality of low light level and infrared fused image under low illumination conditions.
Target detection cycle criteria when using the targeting task performance metric
NASA Astrophysics Data System (ADS)
Hixson, Jonathan G.; Jacobs, Eddie L.; Vollmerhausen, Richard H.
2004-12-01
The US Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate of the US Army (NVESD) has developed a new target acquisition metric to better predict the performance of modern electro-optical imagers. The TTP metric replaces the Johnson criteria. One problem with transitioning to the new model is that the difficulty of searching in a terrain has traditionally been quantified by an "N50." The N50 is the number of Johnson criteria cycles needed for the observer to detect the target half the time, assuming that the observer is not time limited. In order to make use of this empirical data base, a conversion must be found relating Johnson cycles for detection to TTP cycles for detection. This paper describes how that relationship is established. We have found that the relationship between Johnson and TTP is 1:2.7 for the recognition and identification tasks.
Intelligent imaging systems for automotive applications
NASA Astrophysics Data System (ADS)
Thompson, Chris; Huang, Yingping; Fu, Shan
2004-03-01
In common with many other application areas, visual signals are becoming an increasingly important information source for many automotive applications. For several years CCD cameras have been used as research tools for a range of automotive applications. Infrared cameras, RADAR and LIDAR are other types of imaging sensors that have also been widely investigated for use in cars. This paper will describe work in this field performed in C2VIP over the last decade - starting with Night Vision Systems and looking at various other Advanced Driver Assistance Systems. Emerging from this experience, we make the following observations which are crucial for "intelligent" imaging systems: 1. Careful arrangement of sensor array. 2. Dynamic-Self-Calibration. 3. Networking and processing. 4. Fusion with other imaging sensors, both at the image level and the feature level, provides much more flexibility and reliability in complex situations. We will discuss how these problems can be addressed and what are the outstanding issues.
Properties of light reflected from road signs in active imaging for driving safety
NASA Astrophysics Data System (ADS)
Halstuch, Aviran; Yitzhaky, Yitzhak
2007-10-01
Night-vision systems in vehicles are a new emerging technology. A crucial problem in active (illumination-based) systems is distortion of images by saturation and blooming, due to strong retro-reflections from road signs. In this work we quantified this phenomenon. We measured the Mueller matrices and the polarization state of the reflected light from three different types of road signs commonly used. Measurements of the reflected intensity were taken also with respect to the angle of reflection. We found that different types of signs have different reflection properties. It is concluded from our measurements that the optimal solution for attenuating the retro-reflected intensity is using a linear horizontal polarized light source and a linear vertical polarizer. Unfortunately, while the performance of this solution is good for two types of road signs, it is less efficient for the third sign type.
[Diagnosis and treatment of polycythaemia vera: state of the art].
Marton, Imelda; Simon, Zsófia; Borbényi, Zita
2016-10-01
Polycythaemia vera (PV), a condition characterized by blood hyperviscosity due to the expansion of the erythrocyte mass is the most common entity among all Philadelphia chromosome-negative myeloproliferative neoplasms. Arterial and venous thrombotic events are leading determinants of morbidity and mortality but impairment of quality of life due to vasomotor symptoms (erythromelalgia, pruritus) and disease-associated symptoms (tiredness, fatigue, pruritus, night sweats, vision problems, headache, concentration loss, abdominal discomfort, early satiety, fever, weight loss) are also present. The review of polycythaemia vera is actual as the updated WHO 2016 classification of myeloid neoplasms has changed the diagnostic criteria and a new second-line treatment option - JAK1/JAK2 inhibitor ruxolitinib - has been approved for patients who had an inadequate response to or are intolerant of hydroxyurea, which represents a breakthrough in the treatment of this patient population. Orv. Hetil., 2016, 157(44), 1743-1751.
Flight instruments and helmet-mounted SWIR imaging systems
NASA Astrophysics Data System (ADS)
Robinson, Tim; Green, John; Jacobson, Mickey; Grabski, Greg
2011-06-01
Night vision technology has experienced significant advances in the last two decades. Night vision goggles (NVGs) based on gallium arsenide (GaAs) continues to raise the bar for alternative technologies. Resolution, gain, sensitivity have all improved; the image quality through these devices is nothing less than incredible. Panoramic NVGs and enhanced NVGs are examples of recent advances that increase the warfighter capabilities. Even with these advances, alternative night vision devices such as solid-state indium gallium arsenide (InGaAs) focal plane arrays are under development for helmet-mounted imaging systems. The InGaAs imaging system offers advantages over the existing NVGs. Two key advantages are; (1) the new system produces digital image data, and (2) the new system is sensitive to energy in the shortwave infrared (SWIR) spectrum. While it is tempting to contrast the performance of these digital systems to the existing NVGs, the advantage of different spectral detection bands leads to the conclusion that the technologies are less competitive and more synergistic. It is likely, by the end of the decade, pilots within a cockpit will use multi-band devices. As such, flight decks will need to be compatible with both NVGs and SWIR imaging systems. Insertion of NVGs in aircraft during the late 70's and early 80's resulted in many "lessons learned" concerning instrument compatibility with NVGs. These "lessons learned" ultimately resulted in specifications such as MIL-L-85762A and MIL-STD-3009. These specifications are now used throughout industry to produce NVG-compatible illuminated instruments and displays for both military and civilian applications. Inserting a SWIR imaging device in a cockpit will require similar consideration. A project evaluating flight deck instrument compatibility with SWIR devices is currently ongoing; aspects of this evaluation are described in this paper. This project is sponsored by the Air Force Research Laboratory (AFRL).
Vision and the Achievement Gap among Urban Minority Youth
ERIC Educational Resources Information Center
Basch, Charles E.
2011-01-01
Objectives: To outline the prevalence and disparities of vision problems among school-aged urban minority youth, causal pathways through which vision problems adversely affects academic achievement, and proven or promising approaches for schools to address these problems. Methods: Literature review. Results: More than 20% of school-aged youth have…
The impact of the night float system on internal medicine residency programs.
Trontell, M C; Carson, J L; Taragin, M I; Duff, A
1991-01-01
To study the design, method of implementation, perceived benefits, and problems associated with a night float system. Self-administered questionnaire completed by program directors, which included both structured and open-ended questions. The answers reflect resident and student opinions as well as those of the program directors, since program directors regularly obtain feedback from these groups. The 442 accredited internal medicine residency programs listed in the 1988-89 Directory of Graduate Medical Education Programs. Of the 442 programs, 79% responded, and 30% had experience with a night float system. The most frequent methods for initiating a night float system included: decreasing elective time (42.3%), hiring more residents (26.9%), creating a non-teaching service (12.5%), and reallocating housestaff time (9.6%). Positive effects cited include decreased fatigue, improved housestaff morale, improved recruiting, and better attitude toward internal medicine training. The quality of medical care was considered the same or better by most programs using it. The most commonly cited problems were decreased continuity of care, inadequate teaching of the night float team, and miscommunication. Residency programs using a night float system usually observe a positive effect on housestaff morale, recruitment, and working hours and no detrimental effect on the quality of patient care. Miscommunication and inadequate learning experience for the night float team are important potential problems. This survey suggests that the night float represents one solution to reducing resident working hours.
Vignal, Rodolphe; Ollivier, Lénaïck
2011-03-01
To ensure vision readiness on the battlefield, the French military has been providing its soldiers with eyewear since World War I. A military refractive surgery program was initiated in 2008. A prospective questionnaire-based investigation on optical correction and quality of vision among active duty members with visual deficiencies stationed in Djibouti, Africa, was conducted in 2009. It revealed that 59.3% of the soldiers were wearing spectacles, 21.2% were wearing contact lenses--despite official recommendations--and 8.5% had undergone refractive surgery. Satisfaction rates were high with refractive surgery and contact lenses; 33.6% of eyeglass wearers were planning to have surgery. Eye dryness and night vision disturbances were the most reported symptoms following surgery. Military optical devices were under-prescribed before deployment. This suggests that additional and more effective studies on the use of military optical devices should be performed and policy supporting refractive surgery in military populations should be strengthened.
NASA Astrophysics Data System (ADS)
Labin, Amichai M.; Safuri, Shadi K.; Ribak, Erez N.; Perlman, Ido
2014-07-01
Vision starts with the absorption of light by the retinal photoreceptors—cones and rods. However, due to the ‘inverted’ structure of the retina, the incident light must propagate through reflecting and scattering cellular layers before reaching the photoreceptors. It has been recently suggested that Müller cells function as optical fibres in the retina, transferring light illuminating the retinal surface onto the cone photoreceptors. Here we show that Müller cells are wavelength-dependent wave-guides, concentrating the green-red part of the visible spectrum onto cones and allowing the blue-purple part to leak onto nearby rods. This phenomenon is observed in the isolated retina and explained by a computational model, for the guinea pig and the human parafoveal retina. Therefore, light propagation by Müller cells through the retina can be considered as an integral part of the first step in the visual process, increasing photon absorption by cones while minimally affecting rod-mediated vision.
Screening for Vision Problems, Including Usher's Syndrome, among Hearing Impaired Students.
ERIC Educational Resources Information Center
Fillman, Robyn D.; And Others
1987-01-01
A screening program for vision problems and Usher's Syndrome (a common cause of deaf-blindness) among 210 hearing-impaired students found 44 percent had significant vision problems and 1 percent had Usher's Syndrome. The program involved an interagency network of school, health care, and support personnel and utilized a dilated ophathalmological…
The Older Person's Guide to Safe Driving. Public Affairs Pamphlet No. 641.
ERIC Educational Resources Information Center
Brenton, Myron
This pamphlet is a practical guide with helpful suggestions on safe driving for older people. A discussion of the controversy surrounding older people's driving ability begins the pamphlet. Effects of aging on driving are discussed, including affects on vision, twilight and night driving, hearing, muscles and joints, and mental functions. It is…
Rapid Annealing of Iron Implanted Hg(1-x)Cd(x)Te
1990-03-01
Alnrroveii rFoi’ PubikI Release; distributin tilIntl ted DTICELECTEJUN 12 IMU’ BEest Available Cop, D i ..:6 (J,•, 4iL& , AD Rapid Annealing of Ion...Recently, we have received from Or.J. Dinan of the Night Vision and Electro-optic Army Labs at Fort Belvoir a few electrically uncharacterized Hg
1982-03-01
dis- tance of up to 1,200 meters in moonlight . Effective range is substantially reduced with weaker starlight. Night vision devices with...by purification treatment and employment of corrosion inhibitors; by applying protective films to the vulnerable surface (chemically passive, oil...elaborated dynamic stereotype , tanker efficiency Improves, as do march performance Indicators. The duration of this period Is approximately 24 hours
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-08
... enhancements would enable realistic, joint training and testing to support emerging technologies, respond to... visibility require using advanced night vision technology. Training with this equipment can only be conducted... justice and risks to children, subsistence, and cumulative impacts. Public and agency scoping may identify...
Adaptive Red Teaming on Developmental Technologies
2015-09-01
between participating technologies. Power sources such as generators, wind turbines , and solar panels are examples of technology that have high...Day Camera xiv RASE Reconnaissance Advanced Sensor and Exploitation RF radio frequency RFI request for information RGPs rocket...used in night vision equipment, or a more complex electronic attack exploiting a weakness in a wireless network. Technological limitations can be
ERIC Educational Resources Information Center
Smith, Gregory D.; Nunan, Elizabeth; Walker, Claire; Kushel, Dan
2009-01-01
Imaging of artwork is an important aspect of art conservation, technical art history, and art authentication. Many forms of near-infrared (NIR) imaging are used by conservators, archaeologists, forensic scientists, and technical art historians to examine the underdrawings of paintings, to detect damages and restorations, to enhance faded or…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guyot-Sionnest, Philippe; Keuleyan, Sean E.; Lhuillier, Emmanuel
2016-04-19
Nanoparticles, methods of manufacture, devices comprising the nanoparticles, methods of their manufacture, and methods of their use are provided herein. The nanoparticles and devices having photoabsorptions in the range of 1.7 .mu.m to 12 .mu.m and can be used as photoconductors, photodiodes, phototransistors, charge-coupled devices (CCD), luminescent probes, lasers, thermal imagers, night-vision systems, and/or photodetectors.
Ishizuka, Yoichi; Yoshino, Koichi; Takayanagi, Atsushi; Sugihara, Naoki; Maki, Yoshinobu; Kamijyo, Hideyuki
2016-01-01
Objective: The aim of this study was to compare the oral health problems and behavior of full-time male daytime-only and night shift office workers. Methods: The participants were recruited by applying screening procedures to a pool of Japanese registrants in an online database. During the period of 20 February 2015 to 11 March 2015, participants were asked to complete a questionnaire about their oral health. A total of 325 daytime-only workers and 351 workers who sometimes worked night shifts, ages 30 to 69, were analyzed in this study. Results: Overall, the mean number of teeth of the night shift workers was lower than that of the daytime-only workers (p=0.002). When analyzed by age group, a significant difference was seen in the 50-69 age group (p=0.016). The percentage of night shift workers with decayed teeth was higher than that of the daytime-only workers (p<0.001). The night shift workers were more likely to report gingival bleeding (p=0.015) and stomatitis (p=0.025) than the daytime-only workers. The percentage of night shift workers reporting frequent brushing behavior was lower than that of the daytime-only workers (p=0.040). The independent variables found to correlate significantly with tooth decay were night shift work (OR, 1.79; 95% CI, 1.20-2.67), current smoking habit (OR, 1.66; 95% CI, 1.13-2.46), and BMI of ≥25 (OR, 1.56; 95% CI, 1.02-2.39). Conclusions: These results indicate a relationship between night shift work and oral health problems. Night shift workers may require additional support for oral health maintenance. PMID:27010087
Ishizuka, Yoichi; Yoshino, Koichi; Takayanagi, Atsushi; Sugihara, Naoki; Maki, Yoshinobu; Kamijyo, Hideyuki
2016-05-25
The aim of this study was to compare the oral health problems and behavior of full-time male daytime-only and night shift office workers. The participants were recruited by applying screening procedures to a pool of Japanese registrants in an online database. During the period of 20 February 2015 to 11 March 2015, participants were asked to complete a questionnaire about their oral health. A total of 325 daytime-only workers and 351 workers who sometimes worked night shifts, ages 30 to 69, were analyzed in this study. Overall, the mean number of teeth of the night shift workers was lower than that of the daytime-only workers (p=0.002). When analyzed by age group, a significant difference was seen in the 50-69 age group (p=0.016). The percentage of night shift workers with decayed teeth was higher than that of the daytime-only workers (p<0.001). The night shift workers were more likely to report gingival bleeding (p=0.015) and stomatitis (p=0.025) than the daytime-only workers. The percentage of night shift workers reporting frequent brushing behavior was lower than that of the daytime-only workers (p=0.040). The independent variables found to correlate significantly with tooth decay were night shift work (OR, 1.79; 95% CI, 1.20-2.67), current smoking habit (OR, 1.66; 95% CI, 1.13-2.46), and BMI of ≥25 (OR, 1.56; 95% CI, 1.02-2.39). These results indicate a relationship between night shift work and oral health problems. Night shift workers may require additional support for oral health maintenance.
Weiss, S; Schaeffel, F
1993-04-01
1. If the eyes of young chickens are deprived of clear vision by translucent occluders, they develop considerable amounts of axial myopia within days. At the same time, the day time retinal dopamine levels drop by about 30%. Because the retinal dopamine levels of normally sighted chicks also differ diurnally and are low at night, we expected that the rate of axial eye growth might also differ during this time. 2. Unexpectedly, eyes grew in length only during the day (about 0.13 mm/day) and even shrank during the night (about -0.04 mm/night, average net growth +0.09 mm in 24 h). 3. If the eyes were occluded, they grew both during the day and also at night (average net growth: +0.16 mm in 24 h). Therefore, development of deprivation myopia was a result of the lack of growth inhibition at night rather than of excessive growth during the day when the actual deprivation occurred. 4. Suppression of dopaminergic retinal pathways by intravitreal injections of the neurotoxin 6-hydroxy-dopamine (6-OHDA) also suppressed development of deprivation myopia and it restored the growth inhibition at night. With normal visual experience, the drug had no effect on axial eye growth and refractive state. 5. Diurnal growth rhythms of the eyes disappeared under continuous light.(ABSTRACT TRUNCATED AT 250 WORDS)
Features of the Vision of Elderly Pedestrians when Crossing a Road.
Matsui, Yasuhiro; Oikawa, Shoko; Aoki, Yoshio; Sekine, Michiaki; Mitobe, Kazutaka
2014-11-01
The present study clarifies the mechanism by which an accident occurs when an elderly pedestrian crosses a road in front of a car, focusing on features of the central and peripheral vision of elderly pedestrians who are judging when it is safe to cross the road. For the pedestrian's central visual field, we investigated the effect of age on the timing judgment using an actual car. The results for daytime conditions indicate that the elderly pedestrians tended to make later judgments of when they crossed the road from the right side of the driver's view at high car velocities. At night, for a car with its headlights on high beam, the average car-pedestrian distances of elderly pedestrians on the left side of the driver's view were significantly longer than those of young pedestrians at velocities of 20 and 40 km/h. The eyesight of the elderly pedestrians during the day did not affect the timing judgment of crossing a road. At night, for a car with its headlights on either high or low beam, the average car-pedestrian distances of elderly pedestrians having good eyesight were longer than those of elderly pedestrians having poor eyesight, for all car velocities. The color of the car body in the central visual field did not affect the timing judgment of elderly pedestrians crossing the road. Meanwhile, the car-body color in the elderly pedestrian's peripheral vision strongly affected the pedestrian's awareness of the car.
Seeing the Universe: On the Cusp of Technology
NASA Astrophysics Data System (ADS)
Impey, C.
2009-08-01
Since Galileo Galilei turned his modest spyglass to the night sky 400 years ago, his heirs have enhanced his legacy by the method of using successively larger lenses, and then concave mirrors. Astronomers have even succeeded in stilling the night air with flexible optics, letting their telescopes register the sharpest images that optics will allow. New technologies allow the creation of telescopes that would be unrecognizable to Galileo. They don't use glass mirrors or lenses and they often gather radiation that's invisible to the eye. Astronomers have even managed to use the Earth as a telescope. These innovations have given us a sharper vision of the universe, and a better sense of our place in space and time.
Kim, Jong Hyun; Hong, Hyung Gil; Park, Kang Ryoung
2017-05-08
Because intelligent surveillance systems have recently undergone rapid growth, research on accurately detecting humans in videos captured at a long distance is growing in importance. The existing research using visible light cameras has mainly focused on methods of human detection for daytime hours when there is outside light, but human detection during nighttime hours when there is no outside light is difficult. Thus, methods that employ additional near-infrared (NIR) illuminators and NIR cameras or thermal cameras have been used. However, in the case of NIR illuminators, there are limitations in terms of the illumination angle and distance. There are also difficulties because the illuminator power must be adaptively adjusted depending on whether the object is close or far away. In the case of thermal cameras, their cost is still high, which makes it difficult to install and use them in a variety of places. Because of this, research has been conducted on nighttime human detection using visible light cameras, but this has focused on objects at a short distance in an indoor environment or the use of video-based methods to capture multiple images and process them, which causes problems related to the increase in the processing time. To resolve these problems, this paper presents a method that uses a single image captured at night on a visible light camera to detect humans in a variety of environments based on a convolutional neural network. Experimental results using a self-constructed Dongguk night-time human detection database (DNHD-DB1) and two open databases (Korea advanced institute of science and technology (KAIST) and computer vision center (CVC) databases), as well as high-accuracy human detection in a variety of environments, show that the method has excellent performance compared to existing methods.
A Vision in Jeopardy: Royal Navy Maritime Autonomous Systems (MAS)
2017-03-31
Chapter 6 will propose a new MAS vision for the RN. However, before doing so, a fresh look at the problem is required. Consensus of the Problem, Not the... assessment , the RN has failed to deliver any sustainable MAS operational capability. A vision for MAS finally materialized in 2014. Yet, the vision...continuous investment and assessment , the RN has failed to deliver any sustainable MAS operational capability. A vision for MAS finally materialized in
Reinke, Laurens; Özbay, Yusuf; Dieperink, Willem; Tulleken, Jaap E
2015-04-01
In general, sleeping and activity patterns vary between individuals. This attribute, known as chronotype, may affect night shift performance. In the intensive care unit (ICR), night shift performance may impact patient safety. We have investigated the effect of chronotype and social demographics on sleepiness, fatigue, and night shift on the performance of nurses. This was a prospective observational cohort study which assessed the performance of 96 ICU night shift nurses during the day and night shifts in a mixed medical-surgical ICU in the Netherlands. We determined chronotype and assessed sleeping behaviour for each nurse prior to starting shift work and before free days. The level of sleepiness and fatigue of nurses during the day and night shifts was determined, as was the effect of these conditions on psychomotor vigilance and mathematical problem-solving. The majority of ICU nurses had a preference for early activity (morning chronotype). Compared to their counterparts (i.e. evening chronotypes), they were more likely to nap before commencing night shifts and more likely to have young children living at home. Despite increased sleepiness and fatigue during night shifts, no effect on psychomotor vigilance was observed during night shifts. Problem-solving accuracy remained high during night shifts, at the cost of productivity. Most of the ICU night shift nurses assessed here appeared to have adapted well to night shift work, despite the high percentage of morning chronotypes, possibly due to their 8-h shift duration. Parental responsibilities may, however, influence shift work tolerance.
Analog "neuronal" networks in early vision.
Koch, C; Marroquin, J; Yuille, A
1986-01-01
Many problems in early vision can be formulated in terms of minimizing a cost function. Examples are shape from shading, edge detection, motion analysis, structure from motion, and surface interpolation. As shown by Poggio and Koch [Poggio, T. & Koch, C. (1985) Proc. R. Soc. London, Ser. B 226, 303-323], quadratic variational problems, an important subset of early vision tasks, can be "solved" by linear, analog electrical, or chemical networks. However, in the presence of discontinuities, the cost function is nonquadratic, raising the question of designing efficient algorithms for computing the optimal solution. Recently, Hopfield and Tank [Hopfield, J. J. & Tank, D. W. (1985) Biol. Cybern. 52, 141-152] have shown that networks of nonlinear analog "neurons" can be effective in computing the solution of optimization problems. We show how these networks can be generalized to solve the nonconvex energy functionals of early vision. We illustrate this approach by implementing a specific analog network, solving the problem of reconstructing a smooth surface from sparse data while preserving its discontinuities. These results suggest a novel computational strategy for solving early vision problems in both biological and real-time artificial vision systems. PMID:3459172
Collaborative sparse priors for multi-view ATR
NASA Astrophysics Data System (ADS)
Li, Xuelu; Monga, Vishal
2018-04-01
Recent work has seen a surge of sparse representation based classification (SRC) methods applied to automatic target recognition problems. While traditional SRC approaches used l0 or l1 norm to quantify sparsity, spike and slab priors have established themselves as the gold standard for providing general tunable sparse structures on vectors. In this work, we employ collaborative spike and slab priors that can be applied to matrices to encourage sparsity for the problem of multi-view ATR. That is, target images captured from multiple views are expanded in terms of a training dictionary multiplied with a coefficient matrix. Ideally, for a test image set comprising of multiple views of a target, coefficients corresponding to its identifying class are expected to be active, while others should be zero, i.e. the coefficient matrix is naturally sparse. We develop a new approach to solve the optimization problem that estimates the sparse coefficient matrix jointly with the sparsity inducing parameters in the collaborative prior. ATR problems are investigated on the mid-wave infrared (MWIR) database made available by the US Army Night Vision and Electronic Sensors Directorate, which has a rich collection of views. Experimental results show that the proposed joint prior and coefficient estimation method (JPCEM) can: 1.) enable improved accuracy when multiple views vs. a single one are invoked, and 2.) outperform state of the art alternatives particularly when training imagery is limited.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
...), imaging sensor(s), and avionics interfaces that display the sensor imagery on the HUD and overlay it with... that display the sensor imagery, with or without other flight information, on a head-down display. To... infrared sensors can be much different from that detected by natural pilot vision. On a dark night, thermal...
Review of Efforts to Develop a Low-Luminance-Level Disability Glare Tester
2009-09-01
figures 1. LASIK and PRK refractive surgery. .......................................................................................... 6 2...inadequate at this time, particularly for post refractive surgery patients. Early LASIK and PRK produced a very high incidence of night vision...1999). They found that before PRK or LASER in-situ keratomileusis ( LASIK ), simulated pupil dilation from 3 to 7 mm caused a 5-6 fold increase in
Emission Measurements of Ultracell XX25 Reformed Methanol Fuel Cell System
2008-06-01
combination of electrochemical devices such as fuel cell and battery. Polymer electrolyte membrane fuel cells ( PEMFC ) using hydrogen or liquid...communications and computers, sensors and night vision capabilities. High temperature PEMFC offers some advantages such as enhanced electrode kinetics and better...tolerance of carbon monoxide that will poison the conventional PEMFC . Ultracell Corporation, Livermore, California has developed a first
2008-01-01
figure 7), this range allowing for both near and far IR. In essence, the system allows the pilot to see what is normally invisible to the naked eye. 8...contributed to the mid- teen percentage (15.8%) preference for its use during reconnaissance operations. To help qualify preference for reconnaissance
Bilge, Sedat; Aydın, Attila; Bilge, Meltem; Aydın, Cemile; Çevik, Erdem; Eryılmaz, Mehmet
2017-11-01
In the patients with multiple and serious trauma, early applications of life-saving procedures are related to improved survival. We tried to experimentally determine the feasibility of life-saving interventions that are performed with the aid of night vision goggles (NVG) in nighttime combat scenario. Chest tube thoracostomy (CTT), emergency cricothyroidotomy (EC), and needle thoracostomy (NT) interventions were performed by 10 combatant medical staff. The success and duration of interventions were explored in the study. Procedures were performed on the formerly prepared manikins/models in a bright room and in a dark room with the aid of NVG. Operators graded the ease of interventions. All interventions were found successful. Operators stated that both CTT and EC interventions were more difficult in dark than in daytime (p<0.05). No significant difference was observed in the difficulty in the NT interventions. No significant difference was observed in terms of completion times of interventions between in daytime and in dark scenario. The operators who use NVGs have to be aware of that they can perform their tactic and medical activities without taking off the NVGs and without the requirement of an extra light source.
NASA Astrophysics Data System (ADS)
Riantana, R.; Arie, B.; Adam, M.; Aditya, R.; Nuryani; Yahya, I.
2017-02-01
One important thing to pay attention for detecting breast cancer is breast temperature changes. Indications symptoms of breast tissue abnormalities marked by a rise in temperature of the breast. Handycam in night vision mode interferences by external infrared can penetrate into the skin better and can make an infrared image becomes clearer. The program is capable to changing images from a camcorder into a night vision thermal image by breaking RGB into Grayscale matrix structure. The matrix rearranged in the new matrix with double data type so that it can be processed into contour color chart to differentiate the distribution of body temperature. In this program are also features of contrast scale setting of the image is processed so that the color can be set as desired. There was Also a contrast adjustment feature inverse scale that is useful to reverse the color scale so that colors can be changed opposite. There is improfile function used to retrieves the intensity values of pixels along a line what we want to show the distribution of intensity in a graph of relationship between the intensity and the pixel coordinates.
Siddiqi, M A; Kilduff, G M; Gearhart, J D
2003-11-01
We describe the design, construction and testing of a prototype device that allows the direct visualization by eye of far-red and near-infrared (NIR) fluorescence through an optical microscope. The device incorporates a gallium arsenide (GaAs) image intensifier, typically utilized in low-light or 'night vision' applications. The intensifier converts far-red and NIR light into electrons and then into green light, which is visible to the human eye. The prototype makes possible the direct, real-time viewing by eye of normally invisible far-red and NIR fluorescence from a wide variety of fluorophores, using the full field of view of the microscope to which it is applied. The high sensitivity of the image intensifier facilitates the viewing of a wide variety of photosensitive specimens, including live cells and embryos, at vastly reduced illumination levels in both fluorescence and bright-field microscopy. Modifications to the microscope are not required in order to use the prototype, which is fully compatible with all current fluorescence techniques. Refined versions of the prototype device will have broad research and clinical applications.
Infrared imagery acquisition process supporting simulation and real image training
NASA Astrophysics Data System (ADS)
O'Connor, John
2012-05-01
The increasing use of infrared sensors requires development of advanced infrared training and simulation tools to meet current Warfighter needs. In order to prepare the force, a challenge exists for training and simulation images to be both realistic and consistent with each other to be effective and avoid negative training. The US Army Night Vision and Electronic Sensors Directorate has corrected this deficiency by developing and implementing infrared image collection methods that meet the needs of both real image trainers and real-time simulations. The author presents innovative methods for collection of high-fidelity digital infrared images and the associated equipment and environmental standards. The collected images are the foundation for US Army, and USMC Recognition of Combat Vehicles (ROC-V) real image combat ID training and also support simulations including the Night Vision Image Generator and Synthetic Environment Core. The characteristics, consistency, and quality of these images have contributed to the success of these and other programs. To date, this method has been employed to generate signature sets for over 350 vehicles. The needs of future physics-based simulations will also be met by this data. NVESD's ROC-V image database will support the development of training and simulation capabilities as Warfighter needs evolve.
An ancient eye test--using the stars.
Bohigian, George M
2008-01-01
Vision testing in ancient times was as important as it is today. The predominant vision testing in some cultures was the recognition and identification of constellations and celestial bodies of the night sky. A common ancient naked eye test used the double star of the Big Dipper in the constellation Ursa Major or the Big Bear. The second star from the end of the handle of the Big Dipper is an optical double star. The ability to perceive this separation of these two stars, Mizar and Alcor, was considered a test of good vision and was called the "test" or presently the Arab Eye Test. This article is the first report of the correlation of this ancient eye test to the 20/20 line in the current Snellen visual acuity test. This article describes the astronomy, origin, history, and the practicality of this test and how it correlates with the present day Snellen visual acuity test.
Auditory opportunity and visual constraint enabled the evolution of echolocation in bats.
Thiagavel, Jeneni; Cechetto, Clément; Santana, Sharlene E; Jakobsen, Lasse; Warrant, Eric J; Ratcliffe, John M
2018-01-08
Substantial evidence now supports the hypothesis that the common ancestor of bats was nocturnal and capable of both powered flight and laryngeal echolocation. This scenario entails a parallel sensory and biomechanical transition from a nonvolant, vision-reliant mammal to one capable of sonar and flight. Here we consider anatomical constraints and opportunities that led to a sonar rather than vision-based solution. We show that bats' common ancestor had eyes too small to allow for successful aerial hawking of flying insects at night, but an auditory brain design sufficient to afford echolocation. Further, we find that among extant predatory bats (all of which use laryngeal echolocation), those with putatively less sophisticated biosonar have relatively larger eyes than do more sophisticated echolocators. We contend that signs of ancient trade-offs between vision and echolocation persist today, and that non-echolocating, phytophagous pteropodid bats may retain some of the necessary foundations for biosonar.
Development and testing of the EVS 2000 enhanced vision system
NASA Astrophysics Data System (ADS)
Way, Scott P.; Kerr, Richard; Imamura, Joe J.; Arnoldy, Dan; Zeylmaker, Richard; Zuro, Greg
2003-09-01
An effective enhanced vision system must operate over a broad spectral range in order to offer a pilot an optimized scene that includes runway background as well as airport lighting and aircraft operations. The large dynamic range of intensities of these images is best handled with separate imaging sensors. The EVS 2000 is a patented dual-band Infrared Enhanced Vision System (EVS) utilizing image fusion concepts to provide a single image from uncooled infrared imagers in both the LWIR and SWIR. The system is designed to provide commercial and corporate airline pilots with improved situational awareness at night and in degraded weather conditions. A prototype of this system was recently fabricated and flown on the Boeing Advanced Technology Demonstrator 737-900 aircraft. This paper will discuss the current EVS 2000 concept, show results taken from the Boeing Advanced Technology Demonstrator program, and discuss future plans for EVS systems.
Airborne Use of Night Vision Systems
NASA Astrophysics Data System (ADS)
Mepham, S.
1990-04-01
Mission Management Department of the Royal Aerospace Establishment has won a Queen's Award for Technology, jointly with GEC Sensors, in recognition of innovation and success in the development and application of night vision technology for fixed wing aircraft. This work has been carried out to satisfy the operational needs of the Royal Air Force. These are seen to be: - Operations in the NATO Central Region - To have a night as well as a day capability - To carry out low level, high speed penetration - To attack battlefield targets, especially groups of tanks - To meet these objectives at minimum cost The most effective way to penetrate enemy defences is at low level and survivability would be greatly enhanced with a first pass attack. It is therefore most important that not only must the pilot be able to fly at low level to the target but also he must be able to detect it in sufficient time to complete a successful attack. An analysis of the average operating conditions in Central Europe during winter clearly shows that high speed low level attacks can only be made for about 20 per cent of the 24 hours. Extending this into good night conditions raises the figure to 60 per cent. Whilst it is true that this is for winter conditions and in summer the situation is better, the overall advantage to be gained is clear. If our aircraft do not have this capability the potential for the enemy to advance his troops and armour without hinderance for considerable periods is all too obvious. There are several solutions to providing such a capability. The one chosen for Tornado GR1 is to use Terrain Following Radar (TFR). This system is a complete 24 hour capability. However it has two main disadvantages, it is an active system which means it can be jammed or homed into, and is useful in attacking pre-planned targets. Second it is an expensive system which precludes fitting to other than a small number of aircraft.
Improving Night Time Driving Safety Using Vision-Based Classification Techniques.
Chien, Jong-Chih; Chen, Yong-Sheng; Lee, Jiann-Der
2017-09-24
The risks involved in nighttime driving include drowsy drivers and dangerous vehicles. Prominent among the more dangerous vehicles around at night are the larger vehicles which are usually moving faster at night on a highway. In addition, the risk level of driving around larger vehicles rises significantly when the driver's attention becomes distracted, even for a short period of time. For the purpose of alerting the driver and elevating his or her safety, in this paper we propose two components for any modern vision-based Advanced Drivers Assistance System (ADAS). These two components work separately for the single purpose of alerting the driver in dangerous situations. The purpose of the first component is to ascertain that the driver would be in a sufficiently wakeful state to receive and process warnings; this is the driver drowsiness detection component. The driver drowsiness detection component uses infrared images of the driver to analyze his eyes' movements using a MSR plus a simple heuristic. This component issues alerts to the driver when the driver's eyes show distraction and are closed for a longer than usual duration. Experimental results show that this component can detect closed eyes with an accuracy of 94.26% on average, which is comparable to previous results using more sophisticated methods. The purpose of the second component is to alert the driver when the driver's vehicle is moving around larger vehicles at dusk or night time. The large vehicle detection component accepts images from a regular video driving recorder as input. A bi-level system of classifiers, which included a novel MSR-enhanced KAZE-base Bag-of-Features classifier, is proposed to avoid false negatives. In both components, we propose an improved version of the Multi-Scale Retinex (MSR) algorithm to augment the contrast of the input. Several experiments were performed to test the effects of the MSR and each classifier, and the results are presented in experimental results section of this paper.
Improving Night Time Driving Safety Using Vision-Based Classification Techniques
Chien, Jong-Chih; Chen, Yong-Sheng; Lee, Jiann-Der
2017-01-01
The risks involved in nighttime driving include drowsy drivers and dangerous vehicles. Prominent among the more dangerous vehicles around at night are the larger vehicles which are usually moving faster at night on a highway. In addition, the risk level of driving around larger vehicles rises significantly when the driver’s attention becomes distracted, even for a short period of time. For the purpose of alerting the driver and elevating his or her safety, in this paper we propose two components for any modern vision-based Advanced Drivers Assistance System (ADAS). These two components work separately for the single purpose of alerting the driver in dangerous situations. The purpose of the first component is to ascertain that the driver would be in a sufficiently wakeful state to receive and process warnings; this is the driver drowsiness detection component. The driver drowsiness detection component uses infrared images of the driver to analyze his eyes’ movements using a MSR plus a simple heuristic. This component issues alerts to the driver when the driver’s eyes show distraction and are closed for a longer than usual duration. Experimental results show that this component can detect closed eyes with an accuracy of 94.26% on average, which is comparable to previous results using more sophisticated methods. The purpose of the second component is to alert the driver when the driver’s vehicle is moving around larger vehicles at dusk or night time. The large vehicle detection component accepts images from a regular video driving recorder as input. A bi-level system of classifiers, which included a novel MSR-enhanced KAZE-base Bag-of-Features classifier, is proposed to avoid false negatives. In both components, we propose an improved version of the Multi-Scale Retinex (MSR) algorithm to augment the contrast of the input. Several experiments were performed to test the effects of the MSR and each classifier, and the results are presented in experimental results section of this paper. PMID:28946643
Riemann tensor of motion vision revisited.
Brill, M
2001-07-02
This note shows that the Riemann-space interpretation of motion vision developed by Barth and Watson is neither necessary for their results, nor sufficient to handle an intrinsic coordinate problem. Recasting the Barth-Watson framework as a classical velocity-solver (as in computer vision) solves these problems.
Smith, Mark R; Eastman, Charmane I
2012-01-01
There are three mechanisms that may contribute to the health, performance, and safety problems associated with night-shift work: (1) circadian misalignment between the internal circadian clock and activities such as work, sleep, and eating, (2) chronic, partial sleep deprivation, and (3) melatonin suppression by light at night. The typical countermeasures, such as caffeine, naps, and melatonin (for its sleep-promoting effect), along with education about sleep and circadian rhythms, are the components of most fatigue risk-management plans. We contend that these, while better than nothing, are not enough because they do not address the underlying cause of the problems, which is circadian misalignment. We explain how to reset (phase-shift) the circadian clock to partially align with the night-work, day-sleep schedule, and thus reduce circadian misalignment while preserving sleep and functioning on days off. This involves controlling light and dark using outdoor light exposure, sunglasses, sleep in the dark, and a little bright light during night work. We present a diagram of a sleep-and-light schedule to reduce circadian misalignment in permanent night work, or a rotation between evenings and nights, and give practical advice on how to implement this type of plan. PMID:23620685
Spatial contrast sensitivity at twilight: luminance, monocularity, and oxygenation.
Connolly, Desmond M
2010-05-01
Visual performance in dim light is compromised by lack of oxygen (hypoxia). The possible influence of altered oxygenation on foveal contrast sensitivity under mesopic (twilight) viewing conditions is relevant to aircrew flying at night, including when using night vision devices, but is poorly documented. Foveal contrast sensitivity was measured binocularly and monocularly in 12 subjects at 7 spatial frequencies, ranging from 0.5 to approximately 16 cycles per degree, using sinusoidal Gabor patch gratings. Hypoxic performance breathing 14.1% oxygen, equivalent to altitude exposure at 3048 m (10,000 ft), was compared with breathing air at sea level (normoxia) at low photopic (28 cd x m(-2)), borderline upper mesopic (approximately 2.1 cd x m(-2)) and midmesopic (approximately 0.26 cd x m(-2)) luminance. Mesopic performance was also assessed breathing 100% oxygen (hyperoxia). Typical 'inverted U' log/log plots of the contrast sensitivity function were obtained, with elevated thresholds (reduced sensitivity) at lower luminance. Binocular viewing enhanced sensitivity by a factor approximating square root of 2 for most conditions, supporting neural summation of the contrast signal, but had greater influence at the lowest light level and highest spatial frequencies (8.26 and 16.51 cpd). Respiratory challenges had no effect. Contrast sensitivity is poorer when viewing monocularly and especially at midmesopic luminance, with relevance to night flying. The foveal contrast sensitivity function is unaffected by respiratory disturbance when twilight conditions favor cone vision, despite known effects on retinal illumination (pupil size). The resilience of the contrast sensitivity function belies the vulnerability of foveal low contrast acuity to mild hypoxia at mesopic luminance.
Flight performance using a hyperstereo helmet-mounted display: aircraft handling
NASA Astrophysics Data System (ADS)
Jennings, Sion A.; Craig, Gregory L.; Stuart, Geoffrey W.; Kalich, Melvyn E.; Rash, Clarence E.; Harding, Thomas H.
2009-05-01
A flight study was conducted to assess the impact of hyperstereopsis on helicopter handling proficiency, workload and pilot acceptance. Three pilots with varying levels of night vision goggle and hyperstereo helmet-mounted display experience participated in the test. The pilots carried out a series of flights consisting of low-level maneuvers over a period of two weeks. Four of the test maneuvers, The turn around the tail, the hard surface landing, the hover height estimation and the tree-line following were analysed in detail. At the end of the testing period, no significant difference was observed in the performance data, between maneuvers performed with the TopOwl helmet and maneuvers performed with the standard night vision goggle. This study addressed only the image intensification display aspects of the TopOwl helmet system. The tests did not assess the added benefits of overlaid symbology or head slaved infrared camera imagery. These capabilities need to be taken into account when assessing the overall usefulness of the TopOwl system. Even so, this test showed that pilots can utilize the image intensification imagery displayed on the TopOwl to perform benign night flying tasks to an equivalent level as pilots using ANVIS. The study should be extended to investigate more dynamic and aggressive low level flying, slope landings and ship deck landings. While there may be concerns regarding the effect of hyperstereopsis on piloting, this initial study suggests that pilots can either adapt or compensate for hyperstereo effects with sufficient exposure and training. Further analysis and testing is required to determine the extent of training required.
Tunnel Vision in Environmental Management.
ERIC Educational Resources Information Center
Miller, Alan
1982-01-01
Discusses problem-solving styles in environmental management and the specific deficiencies in these styles that might be grouped under the label "tunnel vision," a form of selective attention contributing to inadequate problem-formulation, partial solutions to complex problems, and generation of additional problems. Includes educational…
Development of VIPER: a simulator for assessing vision performance of warfighters
NASA Astrophysics Data System (ADS)
Familoni, Jide; Thompson, Roger; Moyer, Steve; Mueller, Gregory; Williams, Tim; Nguyen, Hung-Quang; Espinola, Richard L.; Sia, Rose K.; Ryan, Denise S.; Rivers, Bruce A.
2016-05-01
Background: When evaluating vision, it is important to assess not just the ability to read letters on a vision chart, but also how well one sees in real life scenarios. As part of the Warfighter Refractive Eye Surgery Program (WRESP), visual outcomes are assessed before and after refractive surgery. A Warfighter's ability to read signs and detect and identify objects is crucial, not only when deployed in a military setting, but also in their civilian lives. Objective: VIPER, a VIsion PERformance simulator was envisioned as actual video-based simulated driving to test warfighters' functional vision under realistic conditions. Designed to use interactive video image controlled environments at daytime, dusk, night, and with thermal imaging vision, it simulates the experience of viewing and identifying road signs and other objects while driving. We hypothesize that VIPER will facilitate efficient and quantifiable assessment of changes in vision and measurement of functional military performance. Study Design: Video images were recorded on an isolated 1.1 mile stretch of road with separate target sets of six simulated road signs and six objects of military interest, separately. The video footage were integrated with customdesigned C++ based software that presented the simulated drive to an observer on a computer monitor at 10, 20 or 30 miles/hour. VIPER permits the observer to indicate when a target is seen and when it is identified. Distances at which the observer recognizes and identifies targets are automatically logged. Errors in recognition and identification are also recorded. This first report describes VIPER's development and a preliminary study to establish a baseline for its performance. In the study, nine soldiers viewed simulations at 10 miles/hour and 30 miles/hour, run in randomized order for each participant seated at 36 inches from the monitor. Relevance: Ultimately, patients are interested in how their vision will affect their ability to perform daily activities. In the military context, in addition to reading road signs, this includes vision with night sensors and identification of objects of military interest. Once completed and validated, VIPER will be used to evaluate functional performance before and after refractive surgery. Results: This initial study was to prove the principle, and its results at the time of this publication were very preliminary. Nine Soldiers viewed visible-day and IR-day VIPER simulations with civilian and military targets, separately, at 10 and 30 miles/hour. Analyses were performed separately for visible and IR, and also aggregated. Only the civilian targets are discussed in this report. At 10 miles/hour, the population detected civilian road signs at an aggregated average of 90.11 +/- 64.20 m, and identified them at 26.93 +/- 22.27m. At 30 miles/hour, the corresponding distances were 103.03 +/- 58.81 and 26.26 +/- 8.55, respectively. Conclusion: This preliminary report proves the principle and suggests that VIPER could be a useful clinical tool in longitudinal assessment of functional vision in warfighters.
Screening for Vision Problems in Children with Hearing Impairments.
ERIC Educational Resources Information Center
Demchak, MaryAnn; Elquist, Marty
Vision problems occur at higher rates in the deaf and hearing impaired population than in the general population. When an individual has a hearing impairment, vision becomes more significant in the instructional and learning process, as well as in social and communicative exchanges. Regular comprehensive visual screening of hearing impaired…
Intrinsically photosensitive retinal ganglion cells.
Do, Michael Tri Hoang; Yau, King-Wai
2010-10-01
Life on earth is subject to alternating cycles of day and night imposed by the rotation of the earth. Consequently, living things have evolved photodetective systems to synchronize their physiology and behavior with the external light-dark cycle. This form of photodetection is unlike the familiar "image vision," in that the basic information is light or darkness over time, independent of spatial patterns. "Nonimage" vision is probably far more ancient than image vision and is widespread in living species. For mammals, it has long been assumed that the photoreceptors for nonimage vision are also the textbook rods and cones. However, recent years have witnessed the discovery of a small population of retinal ganglion cells in the mammalian eye that express a unique visual pigment called melanopsin. These ganglion cells are intrinsically photosensitive and drive a variety of nonimage visual functions. In addition to being photoreceptors themselves, they also constitute the major conduit for rod and cone signals to the brain for nonimage visual functions such as circadian photoentrainment and the pupillary light reflex. Here we review what is known about these novel mammalian photoreceptors.
Integrated cockpit design for the Army helicopter improvement program
NASA Technical Reports Server (NTRS)
Drennen, T.; Bowen, B.
1984-01-01
The main Army Helicopter Improvement Program (AHIP) mission is to navigate precisely, locate targets accurately, communicate their position to other battlefield elements, and to designate them for laser guided weapons. The onboard navigation and mast-mounted sight (MMS) avionics enable accurate tracking of current aircraft position and subsequent target location. The AHIP crewstation development was based on extensive mission/task analysis, function allocation, total system design, and test and verification. The avionics requirements to meet the mission was limited by the existing aircraft structural and performance characteristics and resultant space, weight, and power restrictions. These limitations and night operations requirement led to the use of night vision goggles. The combination of these requirements and limitations dictated an integrated control/display approach using multifunction displays and controls.
Differences in children and adolescents' ability of reporting two CVS-related visual problems.
Hu, Liang; Yan, Zheng; Ye, Tiantian; Lu, Fan; Xu, Peng; Chen, Hao
2013-01-01
The present study examined whether children and adolescents can correctly report dry eyes and blurred distance vision, two visual problems associated with computer vision syndrome. Participants are 913 children and adolescents aged 6-17. They were asked to report their visual problems, including dry eyes and blurred distance vision, and received an eye examination, including tear film break-up time (TFBUT) and visual acuity (VA). Inconsistency was found between participants' reports of dry eyes and TFBUT results among all 913 participants as well as for all of four subgroups. In contrast, consistency was found between participants' reports of blurred distance vision and VA results among 873 participants who had never worn glasses as well as for the four subgroups. It was concluded that children and adolescents are unable to report dry eyes correctly; however, they are able to report blurred distance vision correctly. Three practical implications of the findings were discussed. Little is known about children's ability to report their visual problems, an issue critical to diagnosis and treatment of children's computer vision syndrome. This study compared children's self-reports and clinic examination results and found children can correctly report blurred distance vision but not dry eyes.
Vision Care and the Nation's Children.
ERIC Educational Resources Information Center
American Optometric Association, St. Louis, MO.
Aspects of vision and vision care considered are the following: extent and types of vision defects of American children; importance of vision care in pre-school years, elementary, and secondary school and beyond; and manpower resources in vision care today, the extent of vision testing and care, special problem areas, and governmental support.…
A spiking neural network model of 3D perception for event-based neuromorphic stereo vision systems
Osswald, Marc; Ieng, Sio-Hoi; Benosman, Ryad; Indiveri, Giacomo
2017-01-01
Stereo vision is an important feature that enables machine vision systems to perceive their environment in 3D. While machine vision has spawned a variety of software algorithms to solve the stereo-correspondence problem, their implementation and integration in small, fast, and efficient hardware vision systems remains a difficult challenge. Recent advances made in neuromorphic engineering offer a possible solution to this problem, with the use of a new class of event-based vision sensors and neural processing devices inspired by the organizing principles of the brain. Here we propose a radically novel model that solves the stereo-correspondence problem with a spiking neural network that can be directly implemented with massively parallel, compact, low-latency and low-power neuromorphic engineering devices. We validate the model with experimental results, highlighting features that are in agreement with both computational neuroscience stereo vision theories and experimental findings. We demonstrate its features with a prototype neuromorphic hardware system and provide testable predictions on the role of spike-based representations and temporal dynamics in biological stereo vision processing systems. PMID:28079187
A spiking neural network model of 3D perception for event-based neuromorphic stereo vision systems.
Osswald, Marc; Ieng, Sio-Hoi; Benosman, Ryad; Indiveri, Giacomo
2017-01-12
Stereo vision is an important feature that enables machine vision systems to perceive their environment in 3D. While machine vision has spawned a variety of software algorithms to solve the stereo-correspondence problem, their implementation and integration in small, fast, and efficient hardware vision systems remains a difficult challenge. Recent advances made in neuromorphic engineering offer a possible solution to this problem, with the use of a new class of event-based vision sensors and neural processing devices inspired by the organizing principles of the brain. Here we propose a radically novel model that solves the stereo-correspondence problem with a spiking neural network that can be directly implemented with massively parallel, compact, low-latency and low-power neuromorphic engineering devices. We validate the model with experimental results, highlighting features that are in agreement with both computational neuroscience stereo vision theories and experimental findings. We demonstrate its features with a prototype neuromorphic hardware system and provide testable predictions on the role of spike-based representations and temporal dynamics in biological stereo vision processing systems.
A spiking neural network model of 3D perception for event-based neuromorphic stereo vision systems
NASA Astrophysics Data System (ADS)
Osswald, Marc; Ieng, Sio-Hoi; Benosman, Ryad; Indiveri, Giacomo
2017-01-01
Stereo vision is an important feature that enables machine vision systems to perceive their environment in 3D. While machine vision has spawned a variety of software algorithms to solve the stereo-correspondence problem, their implementation and integration in small, fast, and efficient hardware vision systems remains a difficult challenge. Recent advances made in neuromorphic engineering offer a possible solution to this problem, with the use of a new class of event-based vision sensors and neural processing devices inspired by the organizing principles of the brain. Here we propose a radically novel model that solves the stereo-correspondence problem with a spiking neural network that can be directly implemented with massively parallel, compact, low-latency and low-power neuromorphic engineering devices. We validate the model with experimental results, highlighting features that are in agreement with both computational neuroscience stereo vision theories and experimental findings. We demonstrate its features with a prototype neuromorphic hardware system and provide testable predictions on the role of spike-based representations and temporal dynamics in biological stereo vision processing systems.
Seeing in the dark: vision and visual behaviour in nocturnal bees and wasps.
Warrant, Eric J
2008-06-01
In response to the pressures of predation, parasitism and competition for limited resources, several groups of (mainly) tropical bees and wasps have independently evolved a nocturnal lifestyle. Like their day-active (diurnal) relatives, these insects possess apposition compound eyes, a relatively light-insensitive eye design that is best suited to vision in bright light. Despite this, nocturnal bees and wasps are able to forage at night, with many species capable of flying through a dark and complex forest between the nest and a foraging site, a behaviour that relies heavily on vision and is limited by light intensity. In the two best-studied species - the Central American sweat bee Megalopta genalis (Halictidae) and the Indian carpenter bee Xylocopa tranquebarica (Apidae) - learned visual landmarks are used to guide foraging and homing. Their apposition eyes, however, have only around 30 times greater optical sensitivity than the eyes of their closest diurnal relatives, a fact that is apparently inconsistent with their remarkable nocturnal visual abilities. Moreover, signals generated in the photoreceptors, even though amplified by a high transduction gain, are too noisy and slow to transmit significant amounts of information in dim light. How have nocturnal bees and wasps resolved these paradoxes? Even though this question remains to be answered conclusively, a mounting body of theoretical and experimental evidence suggests that the slow and noisy visual signals generated by the photoreceptors are spatially summed by second-order monopolar cells in the lamina, a process that could dramatically improve visual reliability for the coarser and slower features of the visual world at night.
Nocturnal vision and landmark orientation in a tropical halictid bee.
Warrant, Eric J; Kelber, Almut; Gislén, Anna; Greiner, Birgit; Ribi, Willi; Wcislo, William T
2004-08-10
Some bees and wasps have evolved nocturnal behavior, presumably to exploit night-flowering plants or avoid predators. Like their day-active relatives, they have apposition compound eyes, a design usually found in diurnal insects. The insensitive optics of apposition eyes are not well suited for nocturnal vision. How well then do nocturnal bees and wasps see? What optical and neural adaptations have they evolved for nocturnal vision? We studied female tropical nocturnal sweat bees (Megalopta genalis) and discovered that they are able to learn landmarks around their nest entrance prior to nocturnal foraging trips and to use them to locate the nest upon return. The morphology and optics of the eye, and the physiological properties of the photoreceptors, have evolved to give Megalopta's eyes almost 30 times greater sensitivity to light than the eyes of diurnal worker honeybees, but this alone does not explain their nocturnal visual behavior. This implies that sensitivity is improved by a strategy of photon summation in time and in space, the latter of which requires the presence of specialized cells that laterally connect ommatidia into groups. First-order interneurons, with significantly wider lateral branching than those found in diurnal bees, have been identified in the first optic ganglion (the lamina ganglionaris) of Megalopta's optic lobe. We believe that these cells have the potential to mediate spatial summation. Despite the scarcity of photons, Megalopta is able to visually orient to landmarks at night in a dark forest understory, an ability permitted by unusually sensitive apposition eyes and neural photon summation.
Response to Drs. Shastry and Trese: Phenotype-genotype correlations in X-linked retinitis pigmentosa
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaplan, J.; Munnich, A.
1996-11-11
Shastry and Trese recently reported on a large kindred with X-linked retinitis pigmentosa (XLRP) characterized by a loss of central vision and preserved peripheral function. In their report, the disease had an early onset with severe myopia and a loss of central vision, while night blindness occurred later. Genetic analysis suggested that the disease was linked to the RP2 locus, and the authors raised the question of whether other cases linked to RP2 could display a similar loss of central vision. Three years ago, we reported on 4 large XLRP pedigrees with a very early onset with severe myopia andmore » early loss of visual acuity, while in 5 other families the disease started later with night blindness. We showed that the first clinical form was linked to RP2, while the second was linked to RP3. Thus, the major difference between the two forms concerns the initial symptom, information which can be obtained from the parents and patients after careful questioning. By contrast, in adult life, no difference in either severity of disease or aspect of the fundus was observed in our series, regardless of the clinical subtype of XLRP. Some months later, Jacobson et al. reported on a pedigree with an RP2 genotype, and their data support the notion that in XLRP of RP2 type 1, cone dysfunction takes place first, and as the disease advances both rods and cones are affected. We were very happy, therefore, to read that the study of Shastry and Trese fully confirmed our previous findings. 3 refs.« less
Automated spot defect characterization in a field portable night vision goggle test set
NASA Astrophysics Data System (ADS)
Scopatz, Stephen; Ozten, Metehan; Aubry, Gilles; Arquetoux, Guillaume
2018-05-01
This paper discusses a new capability developed for and results from a field portable test set for Gen 2 and Gen 3 Image Intensifier (I2) tube-based Night Vision Goggles (NVG). A previous paper described the test set and the automated and semi-automated tests supported for NVGs including a Knife Edge MTF test to replace the operator's interpretation of the USAF 1951 resolution chart. The major improvement and innovation detailed in this paper is the use of image analysis algorithms to automate the characterization of spot defects of I² tubes with the same test set hardware previously presented. The original and still common Spot Defect Test requires the operator to look through the NVGs at target of concentric rings; compare the size of the defects to a chart and manually enter the results into a table based on the size and location of each defect; this is tedious and subjective. The prior semi-automated improvement captures and displays an image of the defects and the rings; allowing the operator determine the defects with less eyestrain; while electronically storing the image and the resulting table. The advanced Automated Spot Defect Test utilizes machine vision algorithms to determine the size and location of the defects, generates the result table automatically and then records the image and the results in a computer-generated report easily usable for verification. This is inherently a more repeatable process that ensures consistent spot detection independent of the operator. Results of across several NVGs will be presented.
Hyperstereopsis in night vision devices: basic mechanisms and impact for training requirements
NASA Astrophysics Data System (ADS)
Priot, Anne-Emmanuelle; Hourlier, Sylvain; Giraudet, Guillaume; Leger, Alain; Roumes, Corinne
2006-05-01
Including night vision capabilities in Helmet Mounted Displays has been a serious challenge for many years. The use of "see through" head mounted image intensifiers systems is particularly challenging as it introduces some peculiar visual characteristics usually referred as "hyperstereopsis". Flight testing of such systems has started in the early nineties, both in US and Europe. While the trials conducted in US yielded quite controversial results, convergent positive ones were obtained from European testing, mainly in UK, Germany and France. Subsequently, work on integrating optically coupled I2 tubes on HMD was discontinued in the US, while European manufacturers developed such HMDs for various rotary wings platforms like the TIGER. Coping with hyperstereopsis raises physiological and cognitive human factors issues. Starting in the sixties, effects of increased interocular separation and adaptation to such unusual vision conditions has been quite extensively studied by a number of authors as Wallach, Schor, Judge and Miles, Fisher and Ciuffreda. A synthetic review of literature on this subject will be presented. According to users' reports, three successive phases will be described for habituation to such devices: initial exposure, building compensation phase and behavioral adjustments phase. An habituation model will be suggested to account for HMSD users' reports and literature data bearing on hyperstereopsis, cue weighting for depth perception, adaptation and learning processes, task cognitive control. Finally, some preliminary results on hyperstereopsis spatial and temporal adaptation coming from the survey of training of TIGER pilots, currently conducted at the French-German Army Aviation Training Center, will be unveiled.
Tactical Communications Training Environment for Unmanned Aircraft System Operators
2016-12-15
communication and teamwork skills. The Night Vision Tactical Trainer - Shadow (NVTT-Shadow) was developed as a game -based desktop solution to train...advanced individual training Soldiers and UAS course instructors. The usability testing demonstrated the feasibility of interactive gaming applied to MUM...T tactical communications. Ratings and comments from both students and instructors validated the need as well as mission context, game content, and
NASA Astrophysics Data System (ADS)
Goev, A. I.; Knyazeva, N. A.; Potelov, V. V.; Senik, B. N.
2005-06-01
The present paper represents in detail the complex approach to creating industrial technology of production of polymeric optical components: information has been given on optical polymeric materials, automatic machines for injection moulding, the possibilities of the Moldflow system (the AB "Universal" company) used for mathematical simulation of the technological process of injection moulding and making the moulds.
1945-04-26
England, and compared the speed of their dark adaptation after exposure to a standard illumination with a similar test after staying indoors on a dull ... skylight dark adaptation is considerably delayed. Far from being over in 30 minutes. dark adaptation may not be complete for two hours. An average of all
Innovative Inspection Techniques
1993-01-01
beam and holding the binoculars at the same time. Night-vision glasses with magnification were mentioned but no inspectors we met had direct...angles for an actual lightbulb , the mean spherical candlepower is used as a measure of light output. The MSCP is measured using an integrating...needs special glasses to separate the alternating images, one image for the right and one for the left eye. StereoGraphics Corporation has developed a
Long-Term Counterinsurgency Strategy: Maximizing Special Operations and Airpower
2010-02-01
operations forces possess a repertoire of capabilities and attributes which impart them with unique strategic utility. “That utility reposes most...flashlight), LTMs are employed in a similar role to cue aircrews equipped with Night Vision Devices (NVDs). Concurrently, employment of small laptop...Special Operations Forces (PSS-SOF) and Precision Fires Image Generator (PFIG) have brought similar benefit to the employment of GPS/INS targeted weapons
Tetradymite layer assisted heteroepitaxial growth and applications
Stoica, Vladimir A.; Endicott, Lynn; Clarke, Roy; Uher, Ctirad
2017-08-01
A multilayer stack including a substrate, an active layer, and a tetradymite buffer layer positioned between the substrate and the active layer is disclosed. A method for fabricating a multilayer stack including a substrate, a tetradymite buffer layer and an active layer is also disclosed. Use of such stacks may be in photovoltaics, solar cells, light emitting diodes, and night vision arrays, among other applications.
Enhanced Night Vision Goggle Customer Test
2006-08-01
TASK NUMBER 6. AUTHOR(S) Christian B. Carstens, Charles C. Bonnett, and Elizabeth S. Redden ( all of ARL) 5f. WORK UNIT NUMBER 7...Soldier’s ability to engage and execute close combat, combat support, and combat service support operations in all levels of illumination, adverse...participation: copies of the consent form were provided to all participating subjects. They were given an opportunity to review the experiment
Retinitis Pigmentosa Associated with Glucose-6-Phosphate Dehydrogenase Deficiency.
Thiel, Bryan; Sharma, Aman; Shaikh, Saad
2017-07-23
We report a case of new onset retinitis pigmentosa (RP) associated with a glucose-6-phosphate dehydrogenase (G6PD) deficiency in a 63-year-old African-American male who presented with worsening night vision over a period of five years. The pathogenesis of G6PD-mediated oxidative biological damage is reviewed and a mechanism for the onset of retinal disease proposed.
NASA Astrophysics Data System (ADS)
Zhang, Liandong; Bai, Xiaofeng; Song, De; Fu, Shencheng; Li, Ye; Duanmu, Qingduo
2015-03-01
Low-light-level night vision technology is magnifying low light level signal large enough to be seen by naked eye, which uses the photons - photoelectron as information carrier. Until the micro-channel plate was invented, it has been possibility for the realization of high performance and miniaturization of low-light-level night vision device. The device is double-proximity focusing low-light-level image intensifier which places a micro-channel plate close to photocathode and phosphor screen. The advantages of proximity focusing low-light-level night vision are small size, light weight, small power consumption, no distortion, fast response speed, wide dynamic range and so on. It is placed parallel to each other for Micro-channel plate (both sides of it with metal electrode), the photocathode and the phosphor screen are placed parallel to each other. The voltage is applied between photocathode and the input of micro-channel plate when image intensifier works. The emission electron excited by photo on the photocathode move towards to micro-channel plate under the electric field in 1st proximity focusing region, and then it is multiplied through the micro-channel. The movement locus of emission electrons can be calculated and simulated when the distributions of electrostatic field equipotential lines are determined in the 1st proximity focusing region. Furthermore the resolution of image tube can be determined. However the distributions of electrostatic fields and equipotential lines are complex due to a lot of micro-channel existing in the micro channel plate. This paper simulates electrostatic distribution of 1st proximity region in double-proximity focusing low-light-level image intensifier with the finite element simulation analysis software Ansoft maxwell 3D. The electrostatic field distributions of 1st proximity region are compared when the micro-channel plates' pore size, spacing and inclination angle ranged. We believe that the electron beam movement trajectory in 1st proximity region will be better simulated when the electronic electrostatic fields are simulated.
Vision impairment and dual sensory problems in middle age
Dawes, Piers; Dickinson, Christine; Emsley, Richard; Bishop, Paul; Cruickshanks, Karen; Edmondson-Jones, Mark; McCormack, Abby; Fortnum, Heather; Moore, David R.; Norman, Paul; Munro, Kevin
2014-01-01
Purpose Vision and hearing impairments are known to increase in middle age. In this study we describe the prevalence of vision impairment and dual sensory impairment in UK adults aged 40 to 69 years in a very large and recently ascertained data set. The associations between vision impairment, age, sex, socioeconomic status, and ethnicity are reported. Methods This research was conducted using the UK Biobank Resource, with subsets of UK Biobank data analysed with respect to self-report of eye problems and glasses use. Better-eye visual acuity with habitually worn refractive correction was assessed with a logMAR chart (n = 116,682). Better-ear speech reception threshold was measured with an adaptive speech in noise test, the Digit Triplet Test (n = 164,770). Prevalence estimates were weighted with respect to UK 2001 Census data. Results Prevalence of mild visual impairment and low vision was estimated at 15.2% (95% CI 14.9–15.5%) and 0.9% (95% CI 0.8–1.0%), respectively. Use of glasses was 88.0% (95% CI 87.9–88.1%). The prevalence of dual sensory impairment was 3.1% (95% CI 3.0–3.2%) and there was a nine-fold increase in the prevalence of dual sensory problems between the youngest and oldest age groups. Older adults, those from low socioeconomic and ethnic minority backgrounds were most at risk for vision problems. Conclusions Mild vision impairment is common in middle aged UK adults, despite widespread use of spectacles. Possible barriers to optometric care for those from low socioeconomic and ethnic minority backgrounds may require attention. A higher than expected prevalence of dual impairment suggests that hearing and vision problems share common causes. Optometrists should consider screening for hearing problems, particularly among older adults. PMID:24888710
Yoshinaka, Kiichi; Yamaguchi, Ai; Matsumura, Ritsuko; Node, Koichi; Tokuda, Isao; Akashi, Makoto
2017-10-01
Approximately 20% of workers in developed countries are involved in night work. Nevertheless, many studies have strongly suggested that night-work-induced chronic circadian misalignment increases the risk of a diverse range of health problems. Although a relation between night work and irregular menstrual cycles has been indicated epidemiologically, a direct causal link remains elusive. Here, we report that repetitive reversal of light-dark (LD) cycles triggers irregular estrous cycles in mice. The findings showed that the estrous cycle remained irregular for more than four weeks after the mice were returned to regular LD cycles. Importantly, the magnitude of the negative impact of reversed LD cycles on the estrous cycle, or more specifically the decreased number of normal estrous cycles during the observation period, was dependent on the difference in the frequency of LD reversal. Presently, no clear solution to prevent night-work-mediated menstrual abnormalities is available, and reducing night work in modern society is difficult. Our findings indicate that optimizing work schedules could significantly prevent menstrual problems without reducing total night-work time. © 2017 Molecular Biology Society of Japan and John Wiley & Sons Australia, Ltd.
Childhood Vision: What the Research Tells Us
ERIC Educational Resources Information Center
Center for Health and Health Care in Schools, 2004
2004-01-01
While a nationwide study of vision problems in children has not been conducted in over 30 years, the most recent NHIS (National Health Interview Survey) study shows vision problems are common in children, with an estimated 13.5 million children ages 0-17 affected. As of 2002, 30 states plus the District of Columbia "required" vision…
... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...
Effects of video compression on target acquisition performance
NASA Astrophysics Data System (ADS)
Espinola, Richard L.; Cha, Jae; Preece, Bradley
2008-04-01
The bandwidth requirements of modern target acquisition systems continue to increase with larger sensor formats and multi-spectral capabilities. To obviate this problem, still and moving imagery can be compressed, often resulting in greater than 100 fold decrease in required bandwidth. Compression, however, is generally not error-free and the generated artifacts can adversely affect task performance. The U.S. Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate recently performed an assessment of various compression techniques on static imagery for tank identification. In this paper, we expand this initial assessment by studying and quantifying the effect of various video compression algorithms and their impact on tank identification performance. We perform a series of controlled human perception tests using three dynamic simulated scenarios: target moving/sensor static, target static/sensor static, sensor tracking the target. Results of this study will quantify the effect of video compression on target identification and provide a framework to evaluate video compression on future sensor systems.
Software as a service approach to sensor simulation software deployment
NASA Astrophysics Data System (ADS)
Webster, Steven; Miller, Gordon; Mayott, Gregory
2012-05-01
Traditionally, military simulation has been problem domain specific. Executing an exercise currently requires multiple simulation software providers to specialize, deploy, and configure their respective implementations, integrate the collection of software to achieve a specific system behavior, and then execute for the purpose at hand. This approach leads to rigid system integrations which require simulation expertise for each deployment due to changes in location, hardware, and software. Our alternative is Software as a Service (SaaS) predicated on the virtualization of Night Vision Electronic Sensors (NVESD) sensor simulations as an exemplary case. Management middleware elements layer self provisioning, configuration, and integration services onto the virtualized sensors to present a system of services at run time. Given an Infrastructure as a Service (IaaS) environment, enabled and managed system of simulations yields a durable SaaS delivery without requiring user simulation expertise. Persistent SaaS simulations would provide on demand availability to connected users, decrease integration costs and timelines, and benefit the domain community from immediate deployment of lessons learned.
Vision, eye disease, and art: 2015 Keeler Lecture
Marmor, M F
2016-01-01
The purpose of this study was to examine normal vision and eye disease in relation to art. Ophthalmology cannot explain art, but vision is a tool for artists and its normal and abnormal characteristics may influence what an artist can do. The retina codes for contrast, and the impact of this is evident throughout art history from Asian brush painting, to Renaissance chiaroscuro, to Op Art. Art exists, and can portray day or night, only because of the way retina adjusts to light. Color processing is complex, but artists have exploited it to create shimmer (Seurat, Op Art), or to disconnect color from form (fauvists, expressionists, Andy Warhol). It is hazardous to diagnose eye disease from an artist's work, because artists have license to create as they wish. El Greco was not astigmatic; Monet was not myopic; Turner did not have cataracts. But when eye disease is documented, the effects can be analyzed. Color-blind artists limit their palette to ambers and blues, and avoid greens. Dense brown cataracts destroy color distinctions, and Monet's late canvases (before surgery) showed strange and intense uses of color. Degas had failing vision for 40 years, and his pastels grew coarser and coarser. He may have continued working because his blurred vision smoothed over the rough work. This paper can barely touch upon the complexity of either vision or art. However, it demonstrates some ways in which understanding vision and eye disease give insight into art, and thereby an appreciation of both art and ophthalmology. PMID:26563659
Vision, eye disease, and art: 2015 Keeler Lecture.
Marmor, M F
2016-02-01
The purpose of this study was to examine normal vision and eye disease in relation to art. Ophthalmology cannot explain art, but vision is a tool for artists and its normal and abnormal characteristics may influence what an artist can do. The retina codes for contrast, and the impact of this is evident throughout art history from Asian brush painting, to Renaissance chiaroscuro, to Op Art. Art exists, and can portray day or night, only because of the way retina adjusts to light. Color processing is complex, but artists have exploited it to create shimmer (Seurat, Op Art), or to disconnect color from form (fauvists, expressionists, Andy Warhol). It is hazardous to diagnose eye disease from an artist's work, because artists have license to create as they wish. El Greco was not astigmatic; Monet was not myopic; Turner did not have cataracts. But when eye disease is documented, the effects can be analyzed. Color-blind artists limit their palette to ambers and blues, and avoid greens. Dense brown cataracts destroy color distinctions, and Monet's late canvases (before surgery) showed strange and intense uses of color. Degas had failing vision for 40 years, and his pastels grew coarser and coarser. He may have continued working because his blurred vision smoothed over the rough work. This paper can barely touch upon the complexity of either vision or art. However, it demonstrates some ways in which understanding vision and eye disease give insight into art, and thereby an appreciation of both art and ophthalmology.
Schallhorn, Steven; Tanzer, David; Sanders, Donald R; Sanders, Monica; Brown, Mitch; Kaupp, Sandor E
2010-05-01
To compare changes in simulated night driving performance after Visian Toric Implantable Collamer Lens (TICL; STAAR Surgical) implantation and photorefractive keratectomy (PRK) for the correction of moderate to high myopic astigmatism. This prospective, randomized study consisted of 43 eyes implanted with the TICL (20 bilateral cases) and 45 eyes receiving conventional PRK (VISX Star S3 excimer laser) with mitomycin C (22 bilateral cases) for moderate to high myopia (-6.00 to -20.00 diopters[D] sphere) measured at the spectacle plane and 1.00 to 4.00 D of astigmatism. As a substudy, 27 eyes of 14 TICL patients and 41 eyes of 21 PRK patients underwent a simulated night driving test. The detection and identification distances of road signs and hazards with the Night Driving Simulator (Vision Sciences Research Corp) were measured with and without a glare source before and 6 months after each procedure. No significant difference was noted in the pre- to postoperative Night Driving Simulator in detection distances with and without the glare source between the TICL and PRK groups. The differences in identification distances without glare were significantly better for business and traffic road signs and pedestrian hazards in the TICL group relative to the PRK group whereas with glare, only the pedestrian hazards were significantly better. A clinically relevant change of Night Driving Simulator performance (>0.5 seconds change in ability to identify tasks postoperatively) was significantly better in the TICL group (with and without glare) for all identification tasks. The TICL performed better than conventional PRK in the pre- to postoperative Night Driving Simulator testing with and without a glare source present. Copyright 2010, SLACK Incorporated.
Color Vision Deficiency and Color Blindness: An Introduction to the Problem.
ERIC Educational Resources Information Center
Olsen, Mary Margaret; Harris, Kenneth R.
The paper examines issues concerned with the education and employment of individuals, primarily males, with color vision deficiency. After a brief introduction, the first chapter looks at adult problems such as employment areas in which the disability presents problems. The next chapter considers problems of children, noting the heavy use of color…
... symptoms may include headache or loss of vision. Hypothyroidism symptoms may include feeling cold all the time, ... Vision disorders Problems controlling salt and water balance HYPOTHYROIDISM Heart problems High cholesterol ADRENAL INSUFFICIENCY Inability to ...
Kaur, Gurvinder; Koshy, Jacob; Thomas, Satish; Kapoor, Harpreet; Zachariah, Jiju George; Bedi, Sahiba
2016-04-01
Early detection and treatment of vision problems in children is imperative to meet the challenges of childhood blindness. Considering the problems of inequitable distribution of trained manpower and limited access of quality eye care services to majority of our population, innovative community based strategies like 'Teachers training in vision screening' need to be developed for effective utilization of the available human resources. To evaluate the effectiveness of introducing teachers as the first level vision screeners. Teacher training programs were conducted for school teachers to educate them about childhood ocular disorders and the importance of their early detection. Teachers from government and semi-government schools located in Ludhiana were given training in vision screening. These teachers then conducted vision screening of children in their schools. Subsequently an ophthalmology team visited these schools for re-evaluation of children identified with low vision. Refraction was performed for all children identified with refractive errors and spectacles were prescribed. Children requiring further evaluation were referred to the base hospital. The project was done in two phases. True positives, false positives, true negatives and false negatives were calculated for evaluation. In phase 1, teachers from 166 schools underwent training in vision screening. The teachers screened 30,205 children and reported eye problems in 4523 (14.97%) children. Subsequently, the ophthalmology team examined 4150 children and confirmed eye problems in 2137 children. Thus, the teachers were able to correctly identify eye problems (true positives) in 47.25% children. Also, only 13.69% children had to be examined by the ophthalmology team, thus reducing their work load. Similarly, in phase 2, 46.22% children were correctly identified to have eye problems (true positives) by the teachers. By random sampling, 95.65% children were correctly identified as normal (true negatives) by the teachers. Considering the high true negative rates and reasonably good true positive rates and the wider coverage provided by the program, vision screening in schools by teachers is an effective method of identifying children with low vision. This strategy is also valuable in reducing the workload of the eye care staff.
... pauses in breathing while sleeping) bedwetting (enuresis) night terrors Is Sleepwalking Harmful? Sleepwalking itself is not harmful. ... on this topic for: Parents Kids Teens Night Terrors Nightmares Sleep Problems in Teens All About Sleep ...
Unilateral Macular Star in a Case of Hypertension and Retinitis Pigmentosa.
Chawla, Rohan; Tripathy, Koushik; Chaudhary, Sunil; Phuljhele, Swati; Venkatesh, Pradeep
2017-01-01
To describe a case of hypertension and retinitis pigmentosa presenting with a unilateral macular star. Case report. A 17-year-old female with chronic kidney disease and hypertension presented with a mild blurring of vision in the left eye. There was a history of night blindness. Both eyes had optic disc pallor, arteriolar attenuation, and peripheral bony spicules suggestive of the triad of retinitis pigmentosa. Macular star was seen in the left eye alone. We ascribe the macular star to hypertension as the patient had only a mild decrease in vision, no relative afferent pupillary defect, and similar visual evoked response amplitude and latency in both eyes. Unilateral macular star may be seen in hypertension and may simulate neuroretinitis in the clinical setting.
PixonVision real-time video processor
NASA Astrophysics Data System (ADS)
Puetter, R. C.; Hier, R. G.
2007-09-01
PixonImaging LLC and DigiVision, Inc. have developed a real-time video processor, the PixonVision PV-200, based on the patented Pixon method for image deblurring and denoising, and DigiVision's spatially adaptive contrast enhancement processor, the DV1000. The PV-200 can process NTSC and PAL video in real time with a latency of 1 field (1/60 th of a second), remove the effects of aerosol scattering from haze, mist, smoke, and dust, improve spatial resolution by up to 2x, decrease noise by up to 6x, and increase local contrast by up to 8x. A newer version of the processor, the PV-300, is now in prototype form and can handle high definition video. Both the PV-200 and PV-300 are FPGA-based processors, which could be spun into ASICs if desired. Obvious applications of these processors include applications in the DOD (tanks, aircraft, and ships), homeland security, intelligence, surveillance, and law enforcement. If developed into an ASIC, these processors will be suitable for a variety of portable applications, including gun sights, night vision goggles, binoculars, and guided munitions. This paper presents a variety of examples of PV-200 processing, including examples appropriate to border security, battlefield applications, port security, and surveillance from unmanned aerial vehicles.
Use of 3D vision for fine robot motion
NASA Technical Reports Server (NTRS)
Lokshin, Anatole; Litwin, Todd
1989-01-01
An integration of 3-D vision systems with robot manipulators will allow robots to operate in a poorly structured environment by visually locating targets and obstacles. However, by using computer vision for objects acquisition makes the problem of overall system calibration even more difficult. Indeed, in a CAD based manipulation a control architecture has to find an accurate mapping between the 3-D Euclidean work space and a robot configuration space (joint angles). If a stereo vision is involved, then one needs to map a pair of 2-D video images directly into the robot configuration space. Neural Network approach aside, a common solution to this problem is to calibrate vision and manipulator independently, and then tie them via common mapping into the task space. In other words, both vision and robot refer to some common Absolute Euclidean Coordinate Frame via their individual mappings. This approach has two major difficulties. First a vision system has to be calibrated over the total work space. And second, the absolute frame, which is usually quite arbitrary, has to be the same with a high degree of precision for both robot and vision subsystem calibrations. The use of computer vision to allow robust fine motion manipulation in a poorly structured world which is currently in progress is described along with the preliminary results and encountered problems.
Assessment of the Accountability of Night Vision Devices Provided to the Security Forces of Iraq
2009-03-17
of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering...and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other... data in this project. The qualitative data consisted of individual interviews, direct observation, and written documents. Quantitative data
Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots
2010-04-01
include the following: • Competition for the attention of the wearer/attentional tunneling • Interference with night vision devices • Occlusion...mainstays of society. It is difficult to walk down the street without seeing someone peering at their PDA or BlackBerry * as they are walking. However... BlackBerry is a registered trademark of Research in Motion Limited. 5 A major focus of the Air
Military display performance parameters
NASA Astrophysics Data System (ADS)
Desjardins, Daniel D.; Meyer, Frederick
2012-06-01
The military display market is analyzed in terms of four of its segments: avionics, vetronics, dismounted soldier, and command and control. Requirements are summarized for a number of technology-driving parameters, to include luminance, night vision imaging system compatibility, gray levels, resolution, dimming range, viewing angle, video capability, altitude, temperature, shock and vibration, etc., for direct-view and virtual-view displays in cockpits and crew stations. Technical specifications are discussed for selected programs.
Development of a Night Vision Goggle Heads-Up Display for Paratrooper Guidance
2008-06-01
and GPS data [MIC07]. requiring altitude, position, velocity, acceleration, and angular rates for navigation or control. An internal GPS receiver...Language There are several programming languages that provide the operating capabilities for this program. Languages like JAVA and C# provide an...acceleration, and angular rates. Figure 3.6 illustrates the MIDG hardware’s input and output data. The sensor actually generates the INS data, which is
Technology Support for Combat Casualty Related Medical Infrared Imaging
2011-08-10
LtCol. David Trant USAF as On-site PI, and the Duke Medical IR group (Drs. Pearlstein and Guenther) serving as Co-PI’s, was approved in January 2009...patient outcome. COLLABORATORS: LtCol. Kenneth Egerstrom, USAF; LtCol. David Trant, USAF; Dr. Larry Katz, Department of Emergency Medicine...University of North Carolina Hospitals; Col. Byron Funke, USAF; Dr. David Randall, USArmy Night Vision Laboratories (Ft. Belvoir); Mr. Wayne Antesberger
Distance Estimation to Flashes in a Simulated Night Vision Environment
2007-12-01
indirect perception, which has influenced theorists since, is Hermann von Helmholtz’s theory of unconscious conclusions or unconscious inference [6...Goldstein et al. (Eds.), Blackwell handbook of perception (pp. 53-91). Malden, MA: Blackwell Publishers. [6] Helmholtz, H. von (1867/1925). Treatise on...physiological optics (from 3rd German edition, Vol. III). New York: Dover Publications. [7] Helmholtz, H. von (1878/1968). The facts of perception. In
Guide to Altitude Decompression Sickness Research
2010-05-01
Night Vision Goggles (NVGs) and effects of hypoxia on PRK surgery recovery, F-16 APECS, F-22 Cooling Garment, U-2 Full Pressure Suit, Aircrew...1. Severity 0 No pain 1-2 Mild 3-4 Moderate 5-7 Strong 8-9 Severe 10 Strongest imaginable 2. Intermittent vs . Constant a...symptoms. 2. Intermittent vs . Constant Paresthesia a. Intermittent (Transient) is defined as lasting fewer than 60 seconds each occurrence, in a
The Medical Hazards of Flame-Suppressant Atmospheres
1991-04-19
the external and middle earcavities. Graph B shows inward distension of the may need to be interrupted or slowed to eardrum produced by higher...experiments were performed by mental function, muscular coordination, military scientists (see ACKNOW- night vision, visual contrast sensitivity, LEDGEMENTS) in...task of muscular posure to change any of the visual coordination was slightly function tests (Luria & Knight, degraded during the first 4 h of 1987). the
Performance Based Design of a New Virtual Locomotion Control
2000-11-01
constraints on movements, caloric energy expenditure , etc.). (2) The control action should interact with other actions (looking, manipulation, posturing...velocity, natural cadence, caloric expenditure , etc.) but it is unlikely that one set of tuning parameters will satisfy all criteria. Experimental...tethered for safety. OSIRIS, developed by the US Army’s Night Vision Laboratory, is a stair -stepper device that can only be used upright [Lorenzo et al
The visual standards for the selection and retention of astronauts, part 2
NASA Technical Reports Server (NTRS)
Allen, M. J.; Levene, J. R.; Heath, G. G.
1972-01-01
In preparation for the various studies planned for assessing visual capabilities and tasks in order to set vision standards for astronauts, the following pieces of equipment have been assembled and tested: a spectacle obstruction measuring device, a biometric glare susceptibility tester, a variable vergence amplitude testing device, an eye movement recorder, a lunar illumination simulation chamber, a night myopia testing apparatus, and retinal adaption measuring devices.
Frank, Alan M.; Edwards, William R.
1983-01-01
A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.
Effects of field-of-view restrictions on speed and accuracy of manoeuvring.
Toet, Alexander; Jansen, Sander E M; Delleman, Nico J
2007-12-01
Effects of field-of-view restrictions on the speed and accuracy of participants performing a real-world manoeuvring task through an obstacled environment were investigated. Although field-of-view restrictions are known to affect human behaviour and to degrade performance for a range of different tasks, the relationship between human manoeuvring performance and field-of-view size is not known. This knowledge is essential to evaluate a trade-off between human performance, cost, and ergonomic aspects of field-of-view limiting devises like head-mounted displays and night vision goggles which are frequently deployed for tasks involving human motion through environments with obstacles. In this study the speed and accuracy of movement were measured in 15 participants (8 men, 7 women, 22.9 +/- 2.8 yr. of age) traversing a course formed by three wall segments for different field-of-view restrictions. Analysis showed speed decreased linearly with decreasing field-of-view extent, while accuracy was consistently reduced for all restricted field-of-view conditions. Present results may be used to evaluate cost and performance trade-offs for field-of-view restricting devices deployed to perform time-limited human-locomotion tasks in complex structured environments, such as night-vision goggles and head-mounted displays.
Helicopter cockpit seat side and trapezius muscle metabolism with night vision goggles.
Harrison, Michael F; Neary, J Patrick; Albert, Wayne J; Veillette, Dan W; McKenzie, Neil P; Croll, James C
2007-10-01
Documented neck strain among military helicopter aircrew is becoming more frequent and many militaries use helicopters that provide pilots with the option of sitting in the left or right cockpit seat during missions. The purpose of this study was to use near infrared spectroscopy (NIRS) to investigate the physiological changes in trapezius muscle oxygenation and blood volume during night vision goggle (NVG) flights as a function of left and right cockpit seating. There were 25 pilots who were monitored during NVG flight simulator missions (97.7 +/- 16.1 min). Bilateral NIRS probes attached to the trapezius muscles at C7 level recorded total oxygenation index (TOI, %), total hemoglobin (tHb), oxyhemoglobin (Hbo2), and deoxyhemo-globin (HHb). No significant differences existed between variables for pilots seated in the right cockpit seat as compared with the pilots seated in the left cockpit seat in either trapezius muscle (pTOI = 0.72; ptHb = 0.72; pHbo2 = 0.57; pHHb = 0.21). Alternating cockpit seats on successive missions is not a means to decrease metabolic stress for helicopter pilots using NVG. This suggests that cockpit layout and location of essential instruments with respect to the horizontal and the increased head supported mass of the NVG may be important factors influencing metabolic stress of the trapezius muscle.
The visual ecology of a deep-sea fish, the escolar Lepidocybium flavobrunneum (Smith, 1843)†
Landgren, Eva; Fritsches, Kerstin; Brill, Richard; Warrant, Eric
2014-01-01
Escolar (Lepidocybium flavobrunneum, family Gempylidae) are large and darkly coloured deep-sea predatory fish found in the cold depths (more than 200 m) during the day and in warm surface waters at night. They have large eyes and an overall low density of retinal ganglion cells that endow them with a very high optical sensitivity. Escolar have banked retinae comprising six to eight layers of rods to increase the optical path length for maximal absorption of the incoming light. Their retinae possess two main areae of higher ganglion cell density, one in the ventral retina viewing the dorsal world above (with a moderate acuity of 4.6 cycles deg−1), and the second in the temporal retina viewing the frontal world ahead. Electrophysiological recordings of the flicker fusion frequency (FFF) in isolated retinas indicate that escolar have slow vision, with maximal FFF at the highest light levels and temperatures (around 9 Hz at 23°C) which fall to 1–2 Hz in dim light or cooler temperatures. Our results suggest that escolar are slowly moving sit-and-wait predators. In dim, warm surface waters at night, their slow vision, moderate dorsal resolution and highly sensitive eyes may allow them to surprise prey from below that are silhouetted in the downwelling light. PMID:24395966
Visions of our Planet's Atmosphere, Land and Oceans: NASA/NOAA E-Theater 2003
NASA Technical Reports Server (NTRS)
Hasler, Fritz
2003-01-01
The NASA/NOAA Electronic Theater presents Earth science observations from space in a spectacular way. Fly in from outer space to the conference location as well as the site of the 2002 Olympic Winter Games using data from NASA satellites and the IKONOS 'Spy Satellite". See HDTV movie Destination Earth 2002 incorporating the Olympic Zooms, NBC footage of the 2002 Olympics, the shuttle, & the best NASA/NOAA Earth science visualizations. See the latest US and international global satellite weather movies including hurricanes, typhoons & "tornadoes". See the latest visualizations from NASA/NOAA and International remote sensing missions like Terra, Aqua, GOES, GMS, SeaWiFS, & Landsat. Feel the pulse of OUT planet. See how land vegetation, ocean plankton, clouds and temperatures respond to the sun & seasons. See vortexes and currents in the global oceans that bring up the nutrients to feed tiny algae and draw the fish, whales and fisherman. See the how the ocean blooms in response to these currents and El Nino/La Nina climate changes. See the city lights, fishing fleets, gas flares and bio-mass burning of the Earth at night observed by the "night-vision" DMSP satellite. The presentation will be made using the latest HDTV and video projection technology by: Dr. Fritz Hasler NASA/Goddard Space Flight Center.
Visions of our Planet's Atmosphere, Land and Oceans: NASA/NOAA E-Theater 2003
NASA Technical Reports Server (NTRS)
Hasler, Fritz
2003-01-01
The NASA/NOAA Electronic Theater presents Earth science observations from space in a spectacular way. Fly in from outer space to the conference location as well as the site of the 2002 Olympic Winter Games using data from NASA satellites and the IKONOS "Spy Satellite". See HDTV movie Destination Earth 2002 incorporating the Olympic Zooms, NBC footage of the 2002 Olympics, the shuttle, & the best NASA/NOAA Earth science visualizations. See the latest US and international global satellite weather movies including hurricanes, typhoons & "tornadoes". See the latest visualizations from NASA/NOAA and International remote sensing missions like Terra, Aqua, GOES, GMS, SeaWiFS, & Landsat. Feel the pulse of our planet. See how land vegetation, ocean plankton, clouds and temperatures respond to the sun & seasons. See vortexes and currents in the global oceans that bring up the nutrients to feed tiny algae and draw the fish, whales and fisherman. See the how the ocean blooms in response to these currents and El Nino/La Nina climate changes. See the city lights, fishing fleets, gas flares and bio-mass burning of the Earth at night observed by the "night-vision" DMSP satellite. The presentation will be made using the latest HDTV and video projection technology by: Dr. Fritz Hasler NASA/Goddard Space Flight Center
Visions of our Planet's Atmosphere, Land and Oceans: NASA/NOAA E-Theater 2003
NASA Technical Reports Server (NTRS)
Hasler, Fritz
2003-01-01
The NASA/NOAA Electronic Theater presents Earth science observations from space in a spectacular way. Fly in from outer space to the conference location as well as the site of the 2002 Olympic Winter Games using data from NASA satellites and the IKONOS "Spy Satellite". See HDTV movie Destination Earth 2002 incorporating the Olympic Zooms, NBC footage of the 2002 Olympics, the shuttle, & the best NASA/NOAA Earth science visualizations. See the latest US and international global satellite weather movies including hurricanes, typhoons & "tornadoes". See the latest visualizations from NASA/NOAA and International remote sensing missions like Terra, Aqua, GOES, GMS , SeaWiFS, & Landsat. Feel the pulse of our planet. See how land vegetation, ocean plankton, clouds and temperatures respond to the sun & seasons. See vortexes and currents in the global oceans that bring up the nutrients to feed tiny algae and draw the fish, whales and fisherman. See the how the ocean blooms in response to these currents and El Nino/La Nina climate changes. See the city lights, fishing fleets, gas flares and bio-mass burning of the Earth at night observed by the the "night-vision" DMSP satellite. The presentation will be made using the latest HDTV and video projection technology by: Dr. Fritz Hasler NASA/Goddard Space Flight Center
Vision and Vestibular System Dysfunction Predicts Prolonged Concussion Recovery in Children.
Master, Christina L; Master, Stephen R; Wiebe, Douglas J; Storey, Eileen P; Lockyer, Julia E; Podolak, Olivia E; Grady, Matthew F
2018-03-01
Up to one-third of children with concussion have prolonged symptoms lasting beyond 4 weeks. Vision and vestibular dysfunction is common after concussion. It is unknown whether such dysfunction predicts prolonged recovery. We sought to determine which vision or vestibular problems predict prolonged recovery in children. A retrospective cohort of pediatric patients with concussion. A subspecialty pediatric concussion program. Four hundred thirty-two patient records were abstracted. Presence of vision or vestibular dysfunction upon presentation to the subspecialty concussion program. The main outcome of interest was time to clinical recovery, defined by discharge from clinical follow-up, including resolution of acute symptoms, resumption of normal physical and cognitive activity, and normalization of physical examination findings to functional levels. Study subjects were 5 to 18 years (median = 14). A total of 378 of 432 subjects (88%) presented with vision or vestibular problems. A history of motion sickness was associated with vestibular dysfunction. Younger age, public insurance, and presence of headache were associated with later presentation for subspecialty concussion care. Vision and vestibular problems were associated within distinct clusters. Provocable symptoms with vestibulo-ocular reflex (VOR) and smooth pursuits and abnormal balance and accommodative amplitude (AA) predicted prolonged recovery time. Vision and vestibular problems predict prolonged concussion recovery in children. A history of motion sickness may be an important premorbid factor. Public insurance status may represent problems with disparities in access to concussion care. Vision assessments in concussion must include smooth pursuits, saccades, near point of convergence (NPC), and accommodative amplitude (AA). A comprehensive, multidomain assessment is essential to predict prolonged recovery time and enable active intervention with specific school accommodations and targeted rehabilitation.
Genetics Home Reference: renal coloboma syndrome
... the back of the eye ( the retina ). The vision problems caused by these abnormalities can vary depending ... visual problems, while others may have severely impaired vision. Less common features of renal coloboma syndrome include ...
Facts about Developmental Disabilities
... Children with kernicterus are more likely to have cerebral palsy, hearing and vision problems, and problems with their ... developmental disabilities, such as: ADHD , autism spectrum disorder , cerebral palsy , hearing loss , intellectual disability , learning disability, vision impairment , ...
Sleep and Your Child with Special Needs: What Parents Need to Know
ERIC Educational Resources Information Center
Leadley, Lauri
2011-01-01
Getting a good night's sleep is important to good health for all, but for children with special needs, getting that good night's sleep can be especially difficult. According to a National Sleep Foundation study, more than two-thirds of children experience one or more sleep problems at least a few nights a week. However, studies show that children…
Holloway, Edith E; Xie, Jing; Sturrock, Bonnie A; Lamoureux, Ecosse L; Rees, Gwyneth
2015-05-01
To evaluate the effectiveness of problem-solving interventions on psychosocial outcomes in vision impaired adults. A systematic search of randomised controlled trials (RCTs), published between 1990 and 2013, that investigated the impact of problem-solving interventions on depressive symptoms, emotional distress, quality of life (QoL) and functioning was conducted. Two reviewers independently selected and appraised study quality. Data permitting, intervention effects were statistically pooled and meta-analyses were performed, otherwise summarised descriptively. Eleven studies (reporting on eight trials) met inclusion criteria. Pooled analysis showed problem-solving interventions improved vision-related functioning (standardised mean change [SMC]: 0.15; 95% CI: 0.04-0.27) and emotional distress (SMC: -0.36; 95% CI: -0.54 to -0.19). There was no evidence to support improvements in depressive symptoms (SMC: -0.27, 95% CI: -0.66 to 0.12) and insufficient evidence to determine the effectiveness of problem-solving interventions on QoL. The small number of well-designed studies and narrow inclusion criteria limit the conclusions drawn from this review. However, problem-solving skills may be important for nurturing daily functioning and reducing emotional distress for adults with vision impairment. Given the empirical support for the importance of effective problem-solving skills in managing chronic illness, more well-designed RCTs are needed with diverse vision impaired samples. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Restoration of vision after transplantation of photoreceptors.
Pearson, R A; Barber, A C; Rizzi, M; Hippert, C; Xue, T; West, E L; Duran, Y; Smith, A J; Chuang, J Z; Azam, S A; Luhmann, U F O; Benucci, A; Sung, C H; Bainbridge, J W; Carandini, M; Yau, K-W; Sowden, J C; Ali, R R
2012-05-03
Cell transplantation is a potential strategy for treating blindness caused by the loss of photoreceptors. Although transplanted rod-precursor cells are able to migrate into the adult retina and differentiate to acquire the specialized morphological features of mature photoreceptor cells, the fundamental question remains whether transplantation of photoreceptor cells can actually improve vision. Here we provide evidence of functional rod-mediated vision after photoreceptor transplantation in adult Gnat1−/− mice, which lack rod function and are a model of congenital stationary night blindness. We show that transplanted rod precursors form classic triad synaptic connections with second-order bipolar and horizontal cells in the recipient retina. The newly integrated photoreceptor cells are light-responsive with dim-flash kinetics similar to adult wild-type photoreceptors. By using intrinsic imaging under scotopic conditions we demonstrate that visual signals generated by transplanted rods are projected to higher visual areas, including V1. Moreover, these cells are capable of driving optokinetic head tracking and visually guided behaviour in the Gnat1−/− mouse under scotopic conditions. Together, these results demonstrate the feasibility of photoreceptor transplantation as a therapeutic strategy for restoring vision after retinal degeneration.
Improvement in vision: a new goal for treatment of hereditary retinal degenerations
Jacobson, Samuel G; Cideciyan, Artur V; Aguirre, Gustavo D; Roman, Alejandro J; Sumaroka, Alexander; Hauswirth, William W; Palczewski, Krzysztof
2015-01-01
Introduction: Inherited retinal degenerations (IRDs) have long been considered untreatable and incurable. Recently, one form of early-onset autosomal recessive IRD, Leber congenital amaurosis (LCA) caused by mutations in RPE65 (retinal pigment epithelium-specific protein 65 kDa) gene, has responded with some improvement of vision to gene augmentation therapy and oral retinoid administration. This early success now requires refinement of such therapeutics to fully realize the impact of these major scientific and clinical advances. Areas covered: Progress toward human therapy for RPE65-LCA is detailed from the understanding of molecular mechanisms to preclinical proof-of-concept research to clinical trials. Unexpected positive and complicating results in the patients receiving treatment are explained. Logical next steps to advance the clinical value of the therapeutics are suggested. Expert opinion: The first molecularly based early-phase therapies for an IRD are remarkably successful in that vision has improved and adverse events are mainly associated with surgical delivery to the subretinal space. Yet, there are features of the gene augmentation therapeutic response, such as slowed kinetics of night vision, lack of foveal cone function improvement and relentlessly progressive retinal degeneration despite therapy, that still require research attention. PMID:26246977
Getting drunk safely? Night-life policy in the UK and its public health consequences.
Bellis, Mark A; Hughes, Karen
2011-09-01
Pubs, bars and nightclubs are central features of recreational night-life in the towns and cities of many countries. The last two decades have seen UK towns and cities regenerated through the provision of night-life environments aimed at servicing youth-focused monocultures typified by heavy drinking, loud music and dancing. Such changes in night-life settings have created major problems with management of alcohol-related violence. We examine what policies and interventions have been implemented to reduce violence in public night-life environments. We critically appraise the outcomes of such measures and whether they simply create environments in which it appears 'safe' for people to routinely get drunk while displacing violence and adding to health and social problems elsewhere. KEY FINDINGS/IMPLICATIONS: A variety of initiatives have been put in place to reduce violence and alcohol-related harm in night-time environments. These include changes to licensing laws, high profile policing, late night transport security, street lighting and closed circuit television camera networks. In some circumstances, the evidence for their effectiveness in containing night-life violence is relatively good. However, such approaches can also reduce incentives to stay sober, potentially act as a mechanism for displacing violence into surrounding areas, and divert public monies to city centre drinking environments at the expense of services in local communities. We argue that a public health approach to night-life is required which addresses drunkenness rather than pandering to the economic benefits of excessive alcohol use and managing any violence that is on public display. © 2011 Australasian Professional Society on Alcohol and other Drugs.
Applications: Cloud Height at Night.
ERIC Educational Resources Information Center
Mathematics Teacher, 1980
1980-01-01
The method used at airports in determining the cloud height at night is presented. Several problems, the equation used, and a simple design of an alidade (an instrument that shows cloud heights directly) are also included. (MP)
Fundus white spots and acquired night blindness due to vitamin A deficiency.
Genead, Mohamed A; Fishman, Gerald A; Lindeman, Martin
2009-12-01
To report a successfully treated case of acquired night blindness associated with fundus white spots secondary to vitamin A deficiency. An ocular examination, electrophysiologic testing, as well as visual field and OCT examinations were obtained on a 61-year-old man with vitamin A deficiency who had previously undergone gastric bypass surgery. The patient had a re-evaluation after treatment with high doses of oral vitamin A. The patient was observed to have numerous white spots in the retina of each eye. Best-corrected visual acuity was initially 20/80 in each eye, which improved to 20/40-1 OU after oral vitamin A therapy for 2 months. Full field electroretinogram (ERG) testing, showed non-detectable rod function and a 34 and 41% reduction for 32-Hz flicker and single flash cone responses, respectively, below the lower limits of normal. Both rod and cone functions markedly improved after initiation of vitamin A therapy. Vitamin A deficiency needs to be considered in a patient with white spots of the retina in the presence of poor night vision.
2001 Mars Odyssey Images Earth (Visible and Infrared)
NASA Technical Reports Server (NTRS)
2001-01-01
2001 Mars Odyssey's Thermal Emission Imaging System (THEMIS) acquired these images of the Earth using its visible and infrared cameras as it left the Earth. The visible image shows the thin crescent viewed from Odyssey's perspective. The infrared image was acquired at exactly the same time, but shows the entire Earth using the infrared's 'night-vision' capability. Invisible light the instrument sees only reflected sunlight and therefore sees nothing on the night side of the planet. In infrared light the camera observes the light emitted by all regions of the Earth. The coldest ground temperatures seen correspond to the nighttime regions of Antarctica; the warmest temperatures occur in Australia. The low temperature in Antarctica is minus 50 degrees Celsius (minus 58 degrees Fahrenheit); the high temperature at night in Australia 9 degrees Celsius(48.2 degrees Fahrenheit). These temperatures agree remarkably well with observed temperatures of minus 63 degrees Celsius at Vostok Station in Antarctica, and 10 degrees Celsius in Australia. The images were taken at a distance of 3,563,735 kilometers (more than 2 million miles) on April 19,2001 as the Odyssey spacecraft left Earth.
NASA Astrophysics Data System (ADS)
Goldsmith, John
2014-07-01
The international radio astronomy initiative known as the Square Kilometre Array is a cutting-edge science project, aimed atdramatically expanding our vision and understanding of the Universe. The $2billion+ international project is being shared between Southern Africa and Australia. The Australian component, centred in the Murchison region of Western Australia, is based upon collaboration with Aboriginal communities. A collaborative project called "Ilgarijiri- Things Belonging to the Sky" shared scientific and Aboriginal knowledge of the night sky. Through a series of collaborative meetings and knowledge sharing, the Ilgarijiri project developed and showcased Aboriginal knowledge of the night sky, via an international touring Aboriginal art exhibition, in Australia, South Africa, the USA and Europe. The Aboriginal art exhibition presents Aboriginal stories relating to the night sky, which prominently feature the 'Seven Sisters' and the 'Emu', as well as the collaborative experience with radio astronomers. The success of the Ilgarijiri collaborative project is based upon several principles, which can help to inform and guide future cultural collaborative projects.
NASA Astrophysics Data System (ADS)
Lavers, C.; Franks, K.; Floyd, M.; Plowman, A.
2005-01-01
Advanced electromagnetic sensor systems more commonly associated with the hightech military battlefield may be applied to remote surveillance of wildlife. The first comprehensive study of a wide global variety of Near Infra Red (NIR) and thermal wildlife portraits are presented with this technology: for mammals, birds and other animals. The paper illustrates the safety aspects afforded to zoo staff and personnel in the wild during the day and night from potentially lethal and aggressive animals, and those difficult to approach normally. Such remote sensing systems are non-invasive and provide minimal disruption and distress to animals both in captivity and in the wild. We present some of the veterinarian advantages of such all weather day and night systems to identify sickness and injuries at an early diagnostic stage, as well as age related effects and mammalian cancer. Animals have very different textured surfaces, reflective and emissive properties in the NIR and thermal bands than when compared with the visible spectrum. Some surface features may offer biomimetic materials design advantages.
Night-shift work, sleep duration, daytime napping, and breast cancer risk.
Wang, Pan; Ren, Fang-Mei; Lin, Ying; Su, Feng-Xi; Jia, Wei-Hua; Su, Xue-Fen; Tang, Lu-Ying; Ren, Ze-Fang
2015-04-01
Sleep habits vary among different countries, and sleep problems may cause various health problems. The aim of our study was to evaluate the separate and combined associations of night-shift work, sleep duration, and daytime napping with breast cancer risk among the Chinese population. This study conducted face-to-face interviews with 712 women diagnosed with incident invasive breast cancer before treatment and 742 age-matched controls. Information on sleep habits, demographic characteristics, and suspected or established risk factors of breast cancer were collected from the two groups. Multivariate logistic regression models were used to estimate the odds ratios (ORs) and 95% confidence intervals (CIs). Night-shift work was associated with an increased risk of breast cancer [OR (95% CI): 1.34 (1.05-1.72)]. Compared to women with a sleep duration of 6.1-8.9 h/day, women who had shorter [(≤6.0 h/day) (OR (95% CI): 1.53 (1.10-2.12)] and longer (≥9.0 h/day) sleep duration [(OR (95% CI): 1.59 (1.17-2.17)] had an increased risk of breast cancer. In addition, daytime napping was associated with a reduced risk of breast cancer among night-shift workers [OR (95% CI): 0.57 (0.36-0.90)], but no association was found among women who never had night-shift work [OR (95% CI): 1.01 (0.75-1.35)] (P for interaction = 0.054). Night-shift work and longer sleep duration also synergistically increased breast cancer risk [OR (95% CI): 3.69 (1.94-7.02)] (P for interaction = 0.009). Sleep problems, including night-shift work, and shorter and longer sleep duration, are associated with an increased breast cancer risk. In particular, the combined effects of night-shift work with no daytime napping or longer sleep duration are greater than the independent effects. Copyright © 2014 Elsevier B.V. All rights reserved.
Relationship between fatigue of generation II image intensifier and input illumination
NASA Astrophysics Data System (ADS)
Chen, Qingyou
1995-09-01
If there is fatigue for an image intesifier, then it has an effect on the imaging property of the night vision system. In this paper, using the principle of Joule Heat, we derive a mathematical formula for the generated heat of semiconductor photocathode. We describe the relationship among the various parameters in the formula. We also discuss reasons for the fatigue of Generation II image intensifier caused by bigger input illumination.
NASA Technical Reports Server (NTRS)
1987-01-01
Biomedical Optical Company of America's suntiger lenses eliminate more than 99% of harmful light wavelengths. NASA derived lenses make scenes more vivid in color and also increase the wearer's visual acuity. Distant objects, even on hazy days, appear crisp and clear; mountains seem closer, glare is greatly reduced, clouds stand out. Daytime use protects the retina from bleaching in bright light, thus improving night vision. Filtering helps prevent a variety of eye disorders, in particular cataracts and age related macular degeneration.
Helmet-Mounted Display Design Guide
1997-11-03
flight conditions ( Plaga , 1991). The system need not function during ejection; the criteria should be avoiding further injury. In the past, some...34 Optical En- gineering: 29, 1990, 883-892 E. Peli, "Real Vision and Virtual Reality," Optics and Photonics News, July 1995, pp. 28-34 J. A. Plaga , I...landings. For ejection-seat-equipped aircraft, the cg requirements are based on the I-NIGHTS studies ( Plaga , 1991, and Stickly and Wiley, 1992). The
InP Transferred Electron Cathodes: Basic to Manufacturing Methods
2007-08-29
Source: Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films ; January/February 2003; v.21, no.1, p.219-225 Optimization and...Vacuum, Surfaces and Films ; Sept/Oct 2007 V. 25, No. 5 List of papers submitted or published that acknowledge ARO support during this reporting period...technologies. Night vision devices gather existing ambient light (starlight, moonlight or infra-red light) through a front lens. This light goes into a
Sensor Management for Tactical Surveillance Operations
2007-11-01
active and passive sonar for submarine and tor- pedo detection, and mine avoidance. [range, bearing] range 1.8 km to 55 km Active or Passive AN/SLQ-501...finding (DF) unit [bearing, classification] maximum range 1100 km Passive Cameras (day- light/ night- vision) ( video & still) Record optical and...infrared still images or motion video of events for near-real time assessment or long term analysis and archiving. Range is limited by the image resolution
Night Vision and Electro-Optics Technology Transfer, 1972-1981
1981-09-15
Lixiscope offers potential applications as: a handheld instrument for dental radiography giving real-time ,1servation in orthodontic procedures; a portable...laboratory are described below. There are however, no hard and fast rules. The laboratory’s experimentation with different films, brackets , cameras and...good single lens reflex camera; an exvosure meter; a tripod; and a custom-built bracket to mate the camera and intensifier (Figure 2-1). Figure 2-1
Workshop on Diffuse Discharge Opening Switches (January 13-15, 1982).
1982-04-23
Chairman) Peter Bletzinger Air Force Wright Aeronautical Laboratory Frank DeLucia Duke University Albert Engelhardt Los Alamos National Laboratory...and other gas discharge plasmas," J. Opt. Soc. Am., 68, 352 (1978). 9. P. Camus , M. Dieulin and C. Morillon, "Optogalvanic detection of barium high...Parkway Wright-Patterson AFB, OH 45433 Everett, MA 02149 513/255-2923 617/389-3000 ext. 36 ext. 568 Rudy Buser Albert G. Engelhardt Night Vision and
Uncovering the CH-53E Doppler Myth
2008-01-01
The Corps’ Changing Super Stallion 8 Helicopter Night Vision System 9 Heads-Up Display (BUD) 9 The Infamous Doppler 12 )FUTURE SOLUTIONS 14 Universal...ABSTRACTION FROM, OR REPRODUCTION OF ALL OR ANY PART OF THIS DOCUMENT IS PERMITTED PROVIDED PROPER ACKNOWLEDGEMENT IT MADE. List ofIllustrations Page...remains intimately familiar to those flying the Marine Corps’ CH-53E "Super Stallion " today. Fortunately, the CH.-53Es flown throughout the world today
1990-06-04
Bell NAH-1G (USA 70-15979 NASA-736) FLITE Cobra helicopter hovering on Ames ramp is successor to the original FLITE Cobra. It has been used extensively in joint NASA/Army human factors research in the areas of night vision displays and voice communications since its arrival in 1987. Note: Used in publication in Flight Research at Ames; 57 Years of Development and Validation of Aeronautical Technology NASA SP-1998-3300 fig 140
Frank, A.M.; Edwards, W.R.
1983-10-11
A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision is disclosed. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode. 1 fig.
Frank, A.M.; Edwards, W.R.
1982-03-23
A long-lifetime light source is discussed with sufficiently low intensity to be used for reading a map or other writing at nightime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.
The effect of multispectral image fusion enhancement on human efficiency.
Bittner, Jennifer L; Schill, M Trent; Mohd-Zaid, Fairul; Blaha, Leslie M
2017-01-01
The visual system can be highly influenced by changes to visual presentation. Thus, numerous techniques have been developed to augment imagery in an attempt to improve human perception. The current paper examines the potential impact of one such enhancement, multispectral image fusion, where imagery captured in varying spectral bands (e.g., visible, thermal, night vision) is algorithmically combined to produce an output to strengthen visual perception. We employ ideal observer analysis over a series of experimental conditions to (1) establish a framework for testing the impact of image fusion over the varying aspects surrounding its implementation (e.g., stimulus content, task) and (2) examine the effectiveness of fusion on human information processing efficiency in a basic application. We used a set of rotated Landolt C images captured with a number of individual sensor cameras and combined across seven traditional fusion algorithms (e.g., Laplacian pyramid, principal component analysis, averaging) in a 1-of-8 orientation task. We found that, contrary to the idea of fused imagery always producing a greater impact on perception, single-band imagery can be just as influential. Additionally, efficiency data were shown to fluctuate based on sensor combination instead of fusion algorithm, suggesting the need for examining multiple factors to determine the success of image fusion. Our use of ideal observer analysis, a popular technique from the vision sciences, provides not only a standard for testing fusion in direct relation to the visual system but also allows for comparable examination of fusion across its associated problem space of application.
Blake, Matthew J; Snoep, Lian; Raniti, Monika; Schwartz, Orli; Waloszek, Joanna M; Simmons, Julian G; Murray, Greg; Blake, Laura; Landau, Elizabeth R; Dahl, Ronald E; Bootzin, Richard; McMakin, Dana L; Dudgeon, Paul; Trinder, John; Allen, Nicholas B
2017-12-01
The aim of this study was to test whether a cognitive-behavioral and mindfulness-based group sleep intervention would improve behavior problems in at-risk adolescents, and whether these improvements were specifically related to improvements in sleep. Secondary analysis of a randomized controlled trial conducted with 123 adolescent participants (female = 60%; mean age = 14.48, range 12.04-16.31 years) who had high levels of sleep problems and anxiety symptoms. Participants were randomized into either a sleep improvement intervention (n = 63) or an active control "study skills" intervention (n = 60). Participants completed sleep and behavior problems questionnaires, wore an actiwatch and completed a sleep diary for five school nights, both before and after the intervention. Parallel multiple mediation models showed that postintervention improvements in social problems, attention problems, and aggressive behaviors were specifically mediated by moderate improvements in self-reported sleep quality on school nights, but were not mediated by moderate improvements in actigraphy-assessed sleep onset latency or sleep diary-measured sleep efficiency on school nights. This study provides evidence, using a methodologically rigorous design, that a cognitive-behavioral and mindfulness-based group sleep intervention improved behavior problems in at-risk adolescent by improving perceived sleep quality on school nights. These findings suggest that sleep interventions could be directed towards adolescents with behavior problems. This study was part of The SENSE Study (Sleep and Education: learning New Skills Early). URL: ACTRN12612001177842; http://www.anzctr.org.au/TrialSearch.aspx?searchTxt=ACTRN12612001177842&isBasic=True. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sleep habits in German athletes before important competitions or games.
Erlacher, Daniel; Ehrlenspiel, Felix; Adegbesan, Olufemi A; El-Din, Hamdi Galal
2011-05-01
Sleep is generally regarded as a valuable resource for psychological and physiological well-being. Although the effects of sleep on athletic performance have been acknowledged in sport science, few studies have investigated the prevalence of sleep problems and their effects on elite athletes before a sport event. In this study, 632 German athletes from various sports were asked about their sleep habits during the night(s) before an important competition or game. The findings indicate that 65.8% of the athletes experienced poor sleep in the night(s) before a sports event at least once in their lives and a similarly high percentage (62.3%) had this experience at least once during the previous 12 months. Athletes of individual sports reported more sleep difficulties than athletes of team sports. The main sleep problem was not being able to fall asleep. Internal factors such as nervousness and thoughts about the competition were rated highest for causing sleep problems. Most athletes stated that disturbed sleep had no influence on their athletic performance; however, athletes also reported effects such as a bad mood the following day, increased daytime sleepiness, and worse performance in the competition or game. The differences between individual and team sports indicate that athletes in some sports need more help than those in other sports in managing sleep problems.
The Social Implications of Light at Night
NASA Astrophysics Data System (ADS)
Henshaw, Colin
2015-08-01
Summary: It has been shown that Light at Night (LAN) has serious implications for both the environment and human health. What is considered here are the social implications that arise from these problems, and what needs to be done to redress these issues.Introduction: Light at Night is a serious environmental problem whose environmental and medical implications have been seriously underestimated. If no action is taken the problem will become progressively worse and may reach a point where nothing can be done about it. The issues arising from it need to be identified andappropriate action taken to mitigate these issues as far as possible. Hopefully this can be done amicably by self regulation within communities, but if this fails then stringent anti-light pollution legislation will have to be enacted. Some countries and local authorities have already begun to make faltering steps in this direction1, but so far the measures taken have been minimal and largely ineffective. Light at Night (and the light pollution resulting from it) therefore remains a problem and continues to get worse despite the measures already taken to reduce it. Domes of scattered light continue to hang above our cities, killing off our wildlife and endangering public health. Attitudes need to change and urgent measures need to be taken in order to reduce or eliminate its impact.
Design of DroDeASys (Drowsy Detection and Alarming System)
NASA Astrophysics Data System (ADS)
Juvale, Hrishikesh B.; Mahajan, Anant S.; Bhagwat, Ashwin A.; Badiger, Vishal T.; Bhutkar, Ganesh D.; Dhabe, Priyadarshan S.; Dhore, Manikrao L.
The paper discusses the Drowsy Detection & Alarming System that has been developed, using a non-intrusive approach. The system is basically developed to detect drivers dozing at the wheel at night time driving. The system uses a small infra-red night vision camera that points directly towards the driver`s face and monitors the driver`s eyes in order to detect fatigue. In such a case when fatigue is detected, a warning signal is issued to alert the driver. This paper discusses the algorithms that have been used to detect drowsiness. The decision whether the driver is dozing or not is taken depending on whether the eyes are open for a specific number of frames. If the eyes are found to be closed for a certain number of consecutive frames then the driver is alerted with an alarm.
2011-02-24
CAPE CANAVERAL, Fla. -- Chief Mate Jamie Harris works at the chart table on the bridge at night under a red light so as not to compromise night vision on Freedom Star, one of NASA's solid rocket booster retrieval ships plotting a course in the direction of the left spent booster that splashed down into the Atlantic Ocean after space shuttle Discovery's STS-133 launch. The shuttle’s two solid rocket booster casings and associated flight hardware are recovered in the Atlantic Ocean after every launch by Liberty Star and Freedom Star. The boosters impact the Atlantic about seven minutes after liftoff and the retrieval ships are stationed about 10 miles from the impact area at the time of splashdown. After the spent segments are processed, they will be transported to Utah, where they will be refurbished and stored, if needed. Photo credit: NASA/Ben Smegelsky
Post-Traumatic Stress Disorder and the Earnings of Military Reservists
2013-01-01
such as back pain, fever , rash, and vision problems. After controlling 1 The fact that the PDHA PTSD screen differs from that used by Savoca and...problems Back pain –306** (100) Chest pain –1,018** (147) Chronic cough –341* (136) Diarrhea 48 (107) Fever 538** (149) Joint problems 108...problems associated with PTSD (for example, fevers and vision problems). However, conditions that tend to co-occur with PTSD, such as memory problems
Cheng, Wan-Ju; Cheng, Yawen
2017-07-01
Shift work is associated with adverse physical and psychological health outcomes. However, the independent health effects of night work and rotating shift on workers' sleep and mental health risks and the potential gender differences have not been fully evaluated. We used data from a nationwide survey of representative employees of Taiwan in 2013, consisting of 16 440 employees. Participants reported their work shift patterns 1 week prior to the survey, which were classified into the four following shift types: fixed day, rotating day, fixed night and rotating night shifts. Also obtained were self-reported sleep duration, presence of insomnia, burnout and mental disorder assessed by the Brief Symptom Rating Scale. Among all shift types, workers with fixed night shifts were found to have the shortest duration of sleep, highest level of burnout score, and highest prevalence of insomnia and minor mental disorders. Gender-stratified regression analyses with adjustment of age, education and psychosocial work conditions showed that both in male and female workers, fixed night shifts were associated with greater risks for short sleep duration (<7 hours per day) and insomnia. In female workers, fixed night shifts were also associated with increased risks for burnout and mental disorders, but after adjusting for insomnia, the associations between fixed night shifts and poor mental health were no longer significant. The findings of this study suggested that a fixed night shift was associated with greater risks for sleep and mental health problems, and the associations might be mediated by sleep disturbance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Vision Screening For Head Starters.
ERIC Educational Resources Information Center
Foley, Celia
To determine which children in the Head Start program may have vision problems, Head Start teachers and staff do vision "screening." This booklet demonstrates how to do the screening using the Snellen "E Chart." Trouble signs that the test administrator should be aware of are listed, and vision scores are explained simply.…
West, Kristine L.; Lee, Jongwook
2018-01-01
More than 20 percent of all school-aged children in the United States have vision problems, and low-income and minority children are disproportionately likely to have unmet vision care needs. Vision screening is common in U.S. schools, but it remains an open question whether screening alone is sufficient to improve student outcomes. We implemented a multi-armed randomized controlled trial to evaluate the impact of vision screening, and of vision screening accompanied by eye exams and eyeglasses, provided by a non-profit organization to Title I elementary schools in three large central Florida school districts. We find that providing additional/enhanced screening alone is generally insufficient to improve student achievement in math and reading. In contrast, providing screening along with free eye exams and free eyeglasses to students with vision problems improved student achievement as measured by standardized test scores. We find, averaging over all students (including those without vision problems), that this more comprehensive intervention increased the probability of passing the Florida Comprehensive Achievement Tests (FCAT) in reading and math by approximately 2.0 percentage points. We also present evidence that indicates that this impact fades out over time, indicating that follow-up actions after the intervention may be necessary to sustain these estimated achievement gains. PMID:29693366
Parallel Architectures and Parallel Algorithms for Integrated Vision Systems. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Choudhary, Alok Nidhi
1989-01-01
Computer vision is regarded as one of the most complex and computationally intensive problems. An integrated vision system (IVS) is a system that uses vision algorithms from all levels of processing to perform for a high level application (e.g., object recognition). An IVS normally involves algorithms from low level, intermediate level, and high level vision. Designing parallel architectures for vision systems is of tremendous interest to researchers. Several issues are addressed in parallel architectures and parallel algorithms for integrated vision systems.
MM&T: Precision Machining of Optical Components.
1981-02-01
Center, Naval Weapons Center, Naval Research Laboratory, Naval Air Systems Command, Office of Naval Research, E/O & Night Vision Labs , MICOM, AVRADCOM...Air Force/RDQT lI), Air Force Systens Command, Wright Patterson Mat’l Lab ., I)APPA, TARCOM, ARRADCOM, TSARCOM, Fort Monmouth. 1-- form A-541 I II II I I...sinfle tecnnical iin is ire 1)iill Mulractcrl light Kn njhc r orde us and spatial Oral : reuvtics )etween regularly spaced toot rnaiarks and t-nc rat
2006-06-01
conventional camera vs. thermal imager vs. night vision; camera field of view (narrow, wide, panoramic); keyboard + mouse vs. joystick control vs...motorised platform which could scan the immediate area, producing a 360o panorama of “stitched-together” digital pictures. The picture file, together with...VBS was used to automate the process of creating a QuickTime panorama (.mov or .qt), which includes the initial retrieval of the images, the
Fusion of Night Vision and Thermal Images
2006-12-01
with the walls of the MCP channels. Thus, a thin metal oxide coating commonly known as an ion barrier film is added to the input side of the MCP to...with film ion barrier to filmless gated tubes. An important improvement for Gen 4 products is a greater target identification range and higher target...Metal Seals with S-25 Cathode Mircro-channel plate Ceramic/Metal Seals with GaAS Cathode Mircro-channel plate with ion barrier film Ceramic
1992-01-01
results in stimulation of spatial-motion-location visual processes, which are known to take precedence over any other sensor or cognitive stimuli. In...or version he is flying. This was initially an observation that stimulated the birth of the human-factors engineering discipline during World War H...collisions with the surface, the pilot needs inputs to sensory channels other than the focal visual system. Properly designed auditory and
Huynh, Nancy; Jeffrey, Brett G; Turriff, Amy; Sieving, Paul A; Cukras, Catherine A
2014-03-01
Inherited retinal diseases are uncommon, and the likelihood of having more than one hereditary disorder is rare. Here, we report a case of Stargardt disease and congenital stationary night blindness (CSNB) in the same patient, and the identification of two novel in-frame deletions in the GRM6 gene. The patient underwent an ophthalmic exam and visual function testing including: visual acuity, color vision, Goldmann visual field, and electroretinography (ERG). Imaging of the retina included fundus photography, spectral-domain optical coherence tomography (OCT), and fundus autofluorescence. Genomic DNA was PCR-amplified for analysis of all coding exons and flanking splice sites of both the ABCA4 and GRM6 genes. A 46-year-old woman presented with recently reduced central vision and clinical findings of characteristic yellow flecks consistent with Stargardt disease. However, ERG testing revealed an ERG phenotype unusual for Stargardt disease but consistent with CSNB1. Genetic testing revealed two previously reported mutations in the ABCA4 gene and two novel deletions in the GRM6 gene. Diagnosis of concurrent Stargardt disease and CSNB was made on the ophthalmic history, clinical examination, ERG, and genetic testing. This case highlights that clinical tests need to be taken in context, and that co-existing retinal dystrophies and degenerations should be considered when clinical impressions and objective data do not correlate.
Vision in the dimmest habitats on earth.
Warrant, Eric
2004-10-01
A very large proportion of the world's animal species are active in dim light, either under the cover of night or in the depths of the sea. The worlds they see can be dim and extended, with light reaching the eyes from all directions at once, or they can be composed of bright point sources, like the multitudes of stars seen in a clear night sky or the rare sparks of bioluminescence that are visible in the deep sea. The eye designs of nocturnal and deep-sea animals have evolved in response to these two very different types of habitats, being optimised for maximum sensitivity to extended scenes, or to point sources, or to both. After describing the many visual adaptations that have evolved across the animal kingdom for maximising sensitivity to extended and point-source scenes, I then use case studies from the recent literature to show how these adaptations have endowed nocturnal animals with excellent vision. Nocturnal animals can see colour and negotiate dimly illuminated obstacles during flight. They can also navigate using learned terrestrial landmarks, the constellations of stars or the dim pattern of polarised light formed around the moon. The conclusion from these studies is clear: nocturnal habitats are just as rich in visual details as diurnal habitats are, and nocturnal animals have evolved visual systems capable of exploiting them. The same is certainly true of deep-sea animals, as future research will no doubt reveal.
A self-report critical incident assessment tool for army night vision goggle helicopter operations.
Renshaw, Peter F; Wiggins, Mark W
2007-04-01
The present study sought to examine the utility of a self-report tool that was designed as a partial substitute for a face-to-face cognitive interview for critical incidents involving night vision goggles (NVGs). The use of NVGs remains problematic within the military environment, as these devices have been identified as a factor in a significant proportion of aircraft accidents and incidents. The self-report tool was structured to identify some of the cognitive features of human performance that were associated with critical incidents involving NVGs. The tool incorporated a number of different levels of analysis, ranging from specific behavioral responses to broader cognitive constructs. Reports were received from 30 active pilots within the Australian Army using the NVG Critical Incident Assessment Tool (NVGCIAT). The results revealed a correspondence between specific types of NVG-related errors and elements of the Human Factors Analysis and Classification System (HFACS). In addition, uncertainty emerged as a significant factor associated with the critical incidents that were recalled by operators. These results were broadly consistent with previous research and provide some support for the utility of subjective assessment tools as a means of extracting critical incident-related data when face-to-face cognitive interviews are not possible. In some circumstances, the NVGCIAT might be regarded as a substitute cognitive interview protocol with some level of diagnosticity.
Fukuda, H; Takahashi, M; Miki, K; Haratani, T; Kurabayashi, L; Hisanaga, N; Arito, H; Takahashi, H; Egoshi, M; Sakurai, M
1999-04-01
To assess the shift work-related problems associated with a 16-h night shift in a two-shift system, we took the following important factors into consideration; the interaction between circadian rhythms and the longer night shift, the type of morningness and eveningness experienced, the subjective sleep feeling, the subjects' daily behavior, the effectiveness of taking a nap during the long night shift, and finally the effectiveness of using several different kinds of measuring devices. Included among the measuring devices used were a standard questionnaire, repetitive self-assessment of subjective symptoms and daily behavior at short intervals, and a continuous recording of such objective indices as physical activity and heart rate. A potential problem lies in the fact that field studies that use such measures tend to produce a mass of data, and are thus faced with the accompanying technical problem of analyzing such a large amount of data (time, effort and cost). To solve the data analysis problem, we developed an automated data processing system. Through the use of an image scanner with a paper feeder, standard paper, an optical character recognition function and common application software, we were able to analyze a mass of data continuously and automatically within a short time. Our system should prove useful for field studies that produce a large amount of data collected with several different kinds of measuring devices.
Parents' awareness and perception of children's eye diseases in Nigeria.
Ebeigbe, Jennifer A; Emedike, Chike Martin
Most causes of childhood blindness are treatable or preventable. Knowledge of parents' awareness and perception of eye problems is important in helping to understand parents' eye care seeking behavior. This understanding becomes necessary as early detection and intervention can be effective when done at an early age. Study was carried out in Benin City, Nigeria. Thirty-five parents aged 38-54 years with a mean age of 43(±2) years were recruited. Twenty six were females and nine males. Ten eye care practitioners aged 30-45 years with a mean age of 40 (±2) were included. Seven were males and three were females. Data was analyzed qualitatively and in percentages. Majority of parents were aware of common eye problems: Blurry vision (85.7%), measles in eye (48.5%), cataract (74.3%), conjunctivitis (48.5%), itching and redness (74.3%), crossed eyes (34.3%), strabismus (57.1%), short sightedness (48.5%) and stye or hordeolum (57.1%). Too much carbohydrate, night reading and too much TV were some of the reasons given for bad eyesight. Self medication and use of local remedies for treatment of conjunctivitis was common practice (94.3%). Chloramphenicol eyedrop was the most common drug used for any eye problem before visiting a doctor (80.0%). Parents are aware of common eye diseases in children but have wrong perception of their causes. Programs to increase public awareness of causes of eye problems and harmful effects of self medication are advocated for to expose inherent dangers. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
NASA Technical Reports Server (NTRS)
1990-01-01
Biofeedtrac, Inc.'s Accommotrac Vision Trainer, invented by Dr. Joseph Trachtman, is based on vision research performed by Ames Research Center and a special optometer developed for the Ames program by Stanford Research Institute. In the United States, about 150 million people are myopes (nearsighted), who tend to overfocus when they look at distant objects causing blurry distant vision, or hyperopes (farsighted), whose vision blurs when they look at close objects because they tend to underfocus. The Accommotrac system is an optical/electronic system used by a doctor as an aid in teaching a patient how to contract and relax the ciliary body, the focusing muscle. The key is biofeedback, wherein the patient learns to control a bodily process or function he is not normally aware of. Trachtman claims a 90 percent success rate for correcting, improving or stopping focusing problems. The Vision Trainer has also proved effective in treating other eye problems such as eye oscillation, cross eyes, and lazy eye and in professional sports to improve athletes' peripheral vision and reaction time.
Borges, Renee M.
2018-01-01
The night is a special niche characterized by dim light, lower temperatures, and higher humidity compared to the day. Several animals have made the transition from the day into the night and have acquired unique adaptations to cope with the challenges of performing nocturnal activities. Several plant species have opted to bloom at night, possibly as a response to aridity to prevent excessive water loss through evapotranspiration since flowering is often a water-demanding process, or to protect pollen from heat stress. Nocturnal pollinators have visual adaptations to function under dim light conditions but may also trade off vision against olfaction when they are dependent on nectar-rewarding and scented flowers. Nocturnal pollinators may use CO2 and humidity cues emanating from freshly-opened flowers as indicators of nectar-rich resources. Some endothermic nocturnal insect pollinators are attracted to thermogenic flowers within which they remain to obtain heat as a reward to increase their energy budget. This review focuses on mechanisms that pollinators use to find flowers at night, and the signals that nocturnally blooming flowers may employ to attract pollinators under dim light conditions. It also indicates gaps in our knowledge. While millions of years of evolutionary time have given pollinators and plants solutions to the delivery of pollination services and to the offering of appropriate rewards, this history of successful evolution is being threatened by artificial light at night. Excessive and inappropriate illumination associated with anthropogenic activities has resulted in significant light pollution which serves to undermine life processes governed by dim light. PMID:29599655
NV-CMOS HD camera for day/night imaging
NASA Astrophysics Data System (ADS)
Vogelsong, T.; Tower, J.; Sudol, Thomas; Senko, T.; Chodelka, D.
2014-06-01
SRI International (SRI) has developed a new multi-purpose day/night video camera with low-light imaging performance comparable to an image intensifier, while offering the size, weight, ruggedness, and cost advantages enabled by the use of SRI's NV-CMOS HD digital image sensor chip. The digital video output is ideal for image enhancement, sharing with others through networking, video capture for data analysis, or fusion with thermal cameras. The camera provides Camera Link output with HD/WUXGA resolution of 1920 x 1200 pixels operating at 60 Hz. Windowing to smaller sizes enables operation at higher frame rates. High sensitivity is achieved through use of backside illumination, providing high Quantum Efficiency (QE) across the visible and near infrared (NIR) bands (peak QE <90%), as well as projected low noise (<2h+) readout. Power consumption is minimized in the camera, which operates from a single 5V supply. The NVCMOS HD camera provides a substantial reduction in size, weight, and power (SWaP) , ideal for SWaP-constrained day/night imaging platforms such as UAVs, ground vehicles, fixed mount surveillance, and may be reconfigured for mobile soldier operations such as night vision goggles and weapon sights. In addition the camera with the NV-CMOS HD imager is suitable for high performance digital cinematography/broadcast systems, biofluorescence/microscopy imaging, day/night security and surveillance, and other high-end applications which require HD video imaging with high sensitivity and wide dynamic range. The camera comes with an array of lens mounts including C-mount and F-mount. The latest test data from the NV-CMOS HD camera will be presented.
Borges, Renee M
2018-03-01
The night is a special niche characterized by dim light, lower temperatures, and higher humidity compared to the day. Several animals have made the transition from the day into the night and have acquired unique adaptations to cope with the challenges of performing nocturnal activities. Several plant species have opted to bloom at night, possibly as a response to aridity to prevent excessive water loss through evapotranspiration since flowering is often a water-demanding process, or to protect pollen from heat stress. Nocturnal pollinators have visual adaptations to function under dim light conditions but may also trade off vision against olfaction when they are dependent on nectar-rewarding and scented flowers. Nocturnal pollinators may use CO 2 and humidity cues emanating from freshly-opened flowers as indicators of nectar-rich resources. Some endothermic nocturnal insect pollinators are attracted to thermogenic flowers within which they remain to obtain heat as a reward to increase their energy budget. This review focuses on mechanisms that pollinators use to find flowers at night, and the signals that nocturnally blooming flowers may employ to attract pollinators under dim light conditions. It also indicates gaps in our knowledge. While millions of years of evolutionary time have given pollinators and plants solutions to the delivery of pollination services and to the offering of appropriate rewards, this history of successful evolution is being threatened by artificial light at night. Excessive and inappropriate illumination associated with anthropogenic activities has resulted in significant light pollution which serves to undermine life processes governed by dim light.
A Clear Vision for Equity and Opportunity.
ERIC Educational Resources Information Center
Gould, Marge Christensen; Gould, Herman
2003-01-01
Describes undetected and uncorrected vision problems for children in poverty associated with juvenile delinquency and poor academic performance. Discusses success of a project offering vision screening and free glasses for at-risk students in Tucson, Arizona. (PKP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Zheng; Ukida, H.; Ramuhalli, Pradeep
2010-06-05
Imaging- and vision-based techniques play an important role in industrial inspection. The sophistication of the techniques assures high- quality performance of the manufacturing process through precise positioning, online monitoring, and real-time classification. Advanced systems incorporating multiple imaging and/or vision modalities provide robust solutions to complex situations and problems in industrial applications. A diverse range of industries, including aerospace, automotive, electronics, pharmaceutical, biomedical, semiconductor, and food/beverage, etc., have benefited from recent advances in multi-modal imaging, data fusion, and computer vision technologies. Many of the open problems in this context are in the general area of image analysis methodologies (preferably in anmore » automated fashion). This editorial article introduces a special issue of this journal highlighting recent advances and demonstrating the successful applications of integrated imaging and vision technologies in industrial inspection.« less
Vision and Leadership: Problem-Based Learning as a Teaching Tool
ERIC Educational Resources Information Center
Archbald, Douglas
2013-01-01
We read and hear frequently about the role of vision in leadership. Standards for leadership education programs typically emphasize vision as a core component of leadership education and published accounts of successful leadership usually extol the leader's vision. Given the prevalence of this term in discourse on leadership, it is surprising how…
Reduce volume of head-up display by image stitching
NASA Astrophysics Data System (ADS)
Chiu, Yi-Feng; Su, Guo-Dung J.
2016-09-01
Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.
Evaluation of Helmet Mounted Display Alerting Symbology
NASA Technical Reports Server (NTRS)
DeMaio, Joe; Rutkowski, Michael (Technical Monitor)
2000-01-01
Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.
Zaidman-Zait, Anat; Hall, Wendy A
2015-07-01
To explore associations between children's sleep problems, and behavioural difficulties and parenting approaches. Children commonly have problematic night waking; however, relationships between parenting cognitions and behaviours and children's sleep problems are rarely examined. Longitudinal children's cohort study from 5-29 months post birth. Data were taken from the Quebec Longitudinal Study of Child Development (1998-2007) at three phases: 5, 17 and 29 months of age. Thousand four hundred and eighty-seven families were included in our study based on: participation from phase 1 (5-months old), both parents' reports on parenting cognitions/behaviours and child behavioural difficulties at 29 months, and mothers' reports of children's sleep at 29 months. In 2013, we conducted repeated measures anovas and manovas including children's gender. Extended night-time waking patterns (wakes of ≥20 minutes) were associated with mothers' and fathers' lower sense of parenting impact and higher overprotectiveness and mothers' lower self-efficacy and higher coerciveness for 29-month-old children. In the extended waking group, mothers consistently reported lower self-efficacy, higher overprotectiveness and lower parenting impact at 5, 17 and 29 months. For those children, fathers were only more overprotective at 5 and 29 months. Regarding 29-month-old children's behaviour, children in the extended night waking group had highest scores on externalizing and internalizing behaviours. Girls had higher scores on shyness/inhibition and boys had higher scores on aggression/hyperactivity. Mothers' and fathers' parenting cognitions and behaviours are affected by 29-month-old children's night waking patterns and night waking patterns are associated with children's behavioural problems. © 2015 John Wiley & Sons Ltd.
Design and testing of a dual-band enhanced vision system
NASA Astrophysics Data System (ADS)
Way, Scott P.; Kerr, Richard; Imamura, Joseph J.; Arnoldy, Dan; Zeylmaker, Dick; Zuro, Greg
2003-09-01
An effective enhanced vision system must operate over a broad spectral range in order to offer a pilot an optimized scene that includes runway background as well as airport lighting and aircraft operations. The large dynamic range of intensities of these images is best handled with separate imaging sensors. The EVS 2000 is a patented dual-band Infrared Enhanced Vision System (EVS) utilizing image fusion concepts. It has the ability to provide a single image from uncooled infrared imagers combined with SWIR, NIR or LLLTV sensors. The system is designed to provide commercial and corporate airline pilots with improved situational awareness at night and in degraded weather conditions but can also be used in a variety of applications where the fusion of dual band or multiband imagery is required. A prototype of this system was recently fabricated and flown on the Boeing Advanced Technology Demonstrator 737-900 aircraft. This paper will discuss the current EVS 2000 concept, show results taken from the Boeing Advanced Technology Demonstrator program, and discuss future plans for the fusion system.
Mayo-Wilson, Evan; Imdad, Aamer; Herzer, Kurt; Yakoob, Mohammad Yawar; Bhutta, Zulfiqar A
2011-08-25
To determine if vitamin A supplementation is associated with reductions in mortality and morbidity in children aged 6 months to 5 years. Systematic review and meta-analysis. Two reviewers independently assessed studies for inclusion. Data were double extracted; discrepancies were resolved by discussion. Meta-analyses were performed for mortality, illness, vision, and side effects. Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, Medline, Embase, Global Health, Latin American and Caribbean Health Sciences, metaRegister of Controlled Trials, and African Index Medicus. Databases were searched to April 2010 without restriction by language or publication status. Randomised trials of synthetic oral vitamin A supplements in children aged 6 months to 5 years. Studies of children with current illness (such as diarrhoea, measles, and HIV), studies of children in hospital, and studies of food fortification or β carotene were excluded. 43 trials with about 215,633 children were included. Seventeen trials including 194,483 participants reported a 24% reduction in all cause mortality (rate ratio=0.76, 95% confidence interval 0.69 to 0.83). Seven trials reported a 28% reduction in mortality associated with diarrhoea (0.72, 0.57 to 0.91). Vitamin A supplementation was associated with a reduced incidence of diarrhoea (0.85, 0.82 to 0.87) and measles (0.50, 0.37 to 0.67) and a reduced prevalence of vision problems, including night blindness (0.32, 0.21 to 0.50) and xerophthalmia (0.31, 0.22 to 0.45). Three trials reported an increased risk of vomiting within the first 48 hours of supplementation (2.75, 1.81 to 4.19). Vitamin A supplementation is associated with large reductions in mortality, morbidity, and vision problems in a range of settings, and these results cannot be explained by bias. Further placebo controlled trials of vitamin A supplementation in children between 6 and 59 months of age are not required. However, there is a need for further studies comparing different doses and delivery mechanisms (for example, fortification). Until other sources are available, vitamin A supplements should be given to all children at risk of deficiency, particularly in low and middle income countries.
Mayo-Wilson, Evan; Imdad, Aamer; Herzer, Kurt; Yakoob, Mohammad Yawar
2011-01-01
Objective To determine if vitamin A supplementation is associated with reductions in mortality and morbidity in children aged 6 months to 5 years. Design Systematic review and meta-analysis. Two reviewers independently assessed studies for inclusion. Data were double extracted; discrepancies were resolved by discussion. Meta-analyses were performed for mortality, illness, vision, and side effects. Data sources Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, Medline, Embase, Global Health, Latin American and Caribbean Health Sciences, metaRegister of Controlled Trials, and African Index Medicus. Databases were searched to April 2010 without restriction by language or publication status. Eligibility criteria for selecting studies Randomised trials of synthetic oral vitamin A supplements in children aged 6 months to 5 years. Studies of children with current illness (such as diarrhoea, measles, and HIV), studies of children in hospital, and studies of food fortification or β carotene were excluded. Results 43 trials with about 215 633 children were included. Seventeen trials including 194 483 participants reported a 24% reduction in all cause mortality (rate ratio=0.76, 95% confidence interval 0.69 to 0.83). Seven trials reported a 28% reduction in mortality associated with diarrhoea (0.72, 0.57 to 0.91). Vitamin A supplementation was associated with a reduced incidence of diarrhoea (0.85, 0.82 to 0.87) and measles (0.50, 0.37 to 0.67) and a reduced prevalence of vision problems, including night blindness (0.32, 0.21 to 0.50) and xerophthalmia (0.31, 0.22 to 0.45). Three trials reported an increased risk of vomiting within the first 48 hours of supplementation (2.75, 1.81 to 4.19). Conclusions Vitamin A supplementation is associated with large reductions in mortality, morbidity, and vision problems in a range of settings, and these results cannot be explained by bias. Further placebo controlled trials of vitamin A supplementation in children between 6 and 59 months of age are not required. However, there is a need for further studies comparing different doses and delivery mechanisms (for example, fortification). Until other sources are available, vitamin A supplements should be given to all children at risk of deficiency, particularly in low and middle income countries. PMID:21868478
Helicopter pilot estimation of self-altitude in a degraded visual environment
NASA Astrophysics Data System (ADS)
Crowley, John S.; Haworth, Loran A.; Szoboszlay, Zoltan P.; Lee, Alan G.
2000-06-01
The effect of night vision devices and degraded visual imagery on self-attitude perception is unknown. Thirteen Army aviators with normal vision flew five flights under various visual conditions in a modified AH-1 (Cobra) helicopter. Subjects estimated their altitude or flew to specified altitudes while flying a series of maneuvers. The results showed that subjects were better at detecting and controlling changes in altitude than they were at flying to or naming a specific altitude. In cruise flight and descent, the subjects tended to fly above the desired altitude, an error in the safe direction. While hovering, the direction of error was less predictable. In the low-level cruise flight scenario tested in this study, altitude perception was affected more by changes in image resolution than by changes in FOV or ocularity.
Deep Learning for Computer Vision: A Brief Review
Doulamis, Nikolaos; Doulamis, Anastasios; Protopapadakis, Eftychios
2018-01-01
Over the last years deep learning methods have been shown to outperform previous state-of-the-art machine learning techniques in several fields, with computer vision being one of the most prominent cases. This review paper provides a brief overview of some of the most significant deep learning schemes used in computer vision problems, that is, Convolutional Neural Networks, Deep Boltzmann Machines and Deep Belief Networks, and Stacked Denoising Autoencoders. A brief account of their history, structure, advantages, and limitations is given, followed by a description of their applications in various computer vision tasks, such as object detection, face recognition, action and activity recognition, and human pose estimation. Finally, a brief overview is given of future directions in designing deep learning schemes for computer vision problems and the challenges involved therein. PMID:29487619
Multispectral image-fused head-tracked vision system (HTVS) for driving applications
NASA Astrophysics Data System (ADS)
Reese, Colin E.; Bender, Edward J.
2001-08-01
Current military thermal driver vision systems consist of a single Long Wave Infrared (LWIR) sensor mounted on a manually operated gimbal, which is normally locked forward during driving. The sensor video imagery is presented on a large area flat panel display for direct view. The Night Vision and Electronics Sensors Directorate and Kaiser Electronics are cooperatively working to develop a driver's Head Tracked Vision System (HTVS) which directs dual waveband sensors in a more natural head-slewed imaging mode. The HTVS consists of LWIR and image intensified sensors, a high-speed gimbal, a head mounted display, and a head tracker. The first prototype systems have been delivered and have undergone preliminary field trials to characterize the operational benefits of a head tracked sensor system for tactical military ground applications. This investigation will address the advantages of head tracked vs. fixed sensor systems regarding peripheral sightings of threats, road hazards, and nearby vehicles. An additional thrust will investigate the degree to which additive (A+B) fusion of LWIR and image intensified sensors enhances overall driving performance. Typically, LWIR sensors are better for detecting threats, while image intensified sensors provide more natural scene cues, such as shadows and texture. This investigation will examine the degree to which the fusion of these two sensors enhances the driver's overall situational awareness.
Psychological Adjustment in Adolescents with Vision Impairment
ERIC Educational Resources Information Center
Pinquart, Martin; Pfeiffer, Jens P.
2012-01-01
The present study compared psychological adjustment of 158 adolescents with vision impairment and 158 sighted adolescents with a matched-pair design using the Strengths and Difficulties Questionnaire. Adolescent self-reports and teacher reports on emotional problems, peer problems, and total difficulties showed higher scores in students with…
Khanna, Anjani
2012-01-01
A large number of glaucoma patients suffer from vision impairments that qualify as low vision. Additional difficulties associated with low vision include problems with glare, lighting, and contrast, which can make daily activities extremely challenging. This article elaborates on how low vision aids can help with various tasks that visually impaired glaucoma patients need to do each day, to take care of themselves and to lead an independent life. PMID:27990068
Mothers’ Night Work and Children’s Behavior Problems
Dunifon, Rachel; Kalil, Ariel; Crosby, Danielle; Su, Jessica Houston
2013-01-01
Many mothers work in jobs with nonstandard schedules (i.e., schedules that involve work outside of the traditional 9–5, Monday through Friday schedule); this is particularly true for economically disadvantaged mothers. The present paper uses longitudinal data from the Fragile Families and Child Wellbeing Survey (n = 2,367 mothers of children ages 3–5) to examine the associations between maternal nonstandard work and children’s behavior problems, with a particular focus on mothers’ night shift work. We employ three analytic strategies that take various approaches to adjusting for observed and unobserved selection factors; these approaches provide an upper and lower bound on the true relationship between night shift work and children’s behavior. Taken together, the results provide suggestive evidence for modest associations between exposure to maternal night shift work and higher levels of aggressive and anxious/depressed behavior in children compared to mothers who are not working, those whose mothers work other types of nonstandard shifts, and, for aggressive behavior, those whose mothers work standard shifts. PMID:23294148
Mothers' night work and children's behavior problems.
Dunifon, Rachel; Kalil, Ariel; Crosby, Danielle A; Su, Jessica Houston
2013-10-01
Many mothers work in jobs with nonstandard schedules (i.e., schedules that involve work outside of the traditional 9-5, Monday through Friday schedule); this is particularly true for economically disadvantaged mothers. In the present article, we used longitudinal data from the Fragile Families and Child Wellbeing Survey (n = 2,367 mothers of children ages 3-5 years) to examine the associations between maternal nonstandard work and children's behavior problems, with a particular focus on mothers' night shift work. We employed 3 analytic strategies with various approaches to adjusting for observed and unobserved selection factors; these approaches provided an upper and lower bound on the true relationship between night shift work and children's behavior. Taken together, the results provide suggestive evidence for modest associations between exposure to maternal night shift work and higher levels of aggressive and anxious or depressed behavior in children compared with children whose mothers who are not working, those whose mothers work other types of nonstandard shifts, and, for aggressive behavior, those whose mothers work standard shifts.
[Oguchi disease or stationary congenital night blindness: a case report].
Boissonnot, M; Robert, M F; Gilbert-Dussardier, B; Dighiero, P
2007-01-01
Oguchi disease, originally described in Japanese people, is a rare form of stationary night blindness in patients with normal acuity. We report the case of an 8-year-old girl who presented with an abnormal terrified behavior in the dark. Thorough questioning revealed hemeralopia. Her clinical examination (visual acuity, Goldmann visual field, and color vision) were normal. The fundus examination showed golden-brown color, grayish, almost greenish yellow discoloration in the peripheral area with no osteoclast. This abnormality disappeared after prolonged dark adaptation. The electroretinogram showed a reduced b wave amplitude under scotopic conditions. Her parents were cousins. This diagnosis should be suggested when hemeralopia is associated with typical fundus aspect resolving after dark adaptation (so called Mizuo-Nakamura phenomenon). The long-term prognosis in these patients is good in the absence of clinical progression. This is a genetic autosomal recessive disease caused by mutations in the gene coding for arrestin located in 2q37.1.
Infrared Imaging Sharpens View in Critical Situations
NASA Technical Reports Server (NTRS)
2007-01-01
Innovative Engineering and Consulting (IEC) Infrared Systems, a leading developer of thermal imaging systems and night vision equipment, received a Glenn Alliance for Technology Exchange (GATE) award, half of which was in the form of additional NASA assistance for new product development. IEC Infrared Systems worked with electrical and optical engineers from Glenn's Diagnostics and Data Systems Branch to develop a commercial infrared imaging system that could differentiate the intensity of heat sources better than other commercial systems. The research resulted in two major thermal imaging solutions: NightStalkIR and IntrudIR Alert. These systems are being used in the United States and abroad to help locate personnel stranded in emergency situations, defend soldiers on the battlefield abroad, and protect high-value facilities and operations. The company is also applying its advanced thermal imaging techniques to medical and pharmaceutical product development with a Cleveland-based pharmaceutical company.
2014-02-01
the ISF—night vision devices and ceramic plates for bullet proof vests . With regard to these two articles, we found the following: • INL consulted...However, INL did not consult the directorate about ceramic plates , which INL provided for bullet proof vests that it transferred to the ISF in...did not consult with the directorate about the ceramic plates , INL officials said that INL would contact the directorate in the future about any
Towards Understanding the Role of Colour Information in Scene Perception using Night Vision Device
2009-06-01
possessing a visual system much simplified from that of living birds, reptiles, and teleost (bony) fish , which are generally tetrachromatic (Bowmaker...Levkowitz and Herman (1992) speculated that the results might be limited to “ blob ” detection. A possible mediating factor may have been the size and...sharpness of the “ blobs ” used in their task. Mullen (1985) showed that the visual system is much more sensitive to the 7 DSTO-RR-0345 high spatial
1986-09-01
source of the module/system. Source options are; battery, gas, cartridge, valve , and miscellaneous costs. NAMELIST OPERAT is used to compile the...hardware costs allocated to transportation for packing. TF1 = Initial transportation factor. WEIGHT = Shipping weight of total system. XSUM = System float...CD(6,I)+CD(9,I). . AROC(7,I) - Replenishment spares by year. CD(4,I) - Valve replacement cost by year. CD(5,I) = Cartridge replacement cost by year
1983-06-01
Niven, J.I., McFarland, R.A., and Roughton, F.J. Variations in Visual Thresholds During Carbon Monoxide and Hypoxic Anoxia (abstract). Fed. Proc...and Niven, J.I. Visual Thresholds as an Index of the Modification of the Effects of Anoxia by Glucose. Am. J. Physiol. 144:378-88. 1945. 71... Diphosphoglycerate and Night Vision. Aviat. Space Environ. Med. 52(1):41-44. 1981. 100. Sexton, M., Malone, F. and Farnsworth, D. The Effect of Ultra- violet
Advanced Sensors Boost Optical Communication, Imaging
NASA Technical Reports Server (NTRS)
2009-01-01
Brooklyn, New York-based Amplification Technologies Inc. (ATI), employed Phase I and II SBIR funding from NASA s Jet Propulsion Laboratory to forward the company's solid-state photomultiplier technology. Under the SBIR, ATI developed a small, energy-efficient, extremely high-gain sensor capable of detecting light down to single photons in the near infrared wavelength range. The company has commercialized this technology in the form of its NIRDAPD photomultiplier, ideal for use in free space optical communications, lidar and ladar, night vision goggles, and other light sensing applications.
Coalition Warfare Program Presentation to: 2009 EUCOM/AFRICOM Science and Technology Conference
2009-06-01
compac an nexpens ve m cro- fluxgate magnetometer for use in multiple COCOMs. To continue T&E with joint services and apply lessons learned to...Partners in EUCOM/AFRICOM FY08 Starts • Advanced Dynamic Magnetometer FY09 Starts • ADNS Coalition Network FY10 New Starts • Clip-on Night Vision...Partner 2008 New Starts Advanced Dynamic Magnetometer for Static and Moving Applications T d l t d i i i US Navy (SPAWAR) Italy, Sweden o eve op a a
Air Land Sea Bulletin. Issue No. 2010-3, September 2010
2010-09-01
with M2A3 BFVs during a Quick Response Force mission in Sadr City, Iraq, in support of Operation IRAQI FREEDOM. (Photo by SSgt Ashley Brokop, USAF... M2A3 Bradley Fighting Vehicles (BFVs) into the CLC area of defense. The night vision devices and thermal sites on the vehicles allowed us to...fields determined that an outer cordon would best be achieved by tracked vehicles. The M2A3 and M1A2 BFVs could better sustain IED blasts and
Visual Aids and Eye Protection for the Aviator
1976-10-01
pigmentosa patients. Retinitis pigmen- toss robs you of your night vision very quickly. You still can see centrally and in the daytime but very little at...AND VISUAL AIDS by D.H.Brennan CI INTEGRATION OF AVIATOR’S EYE PROTECTION AND VISUAL AIDS by G.TChisum and P.E.Morway C2 PROTECTION FROM RETINAL BURNS...ensure that infra red wavelengths outside the visible band (MOO-1400 nm) are also attenuated to avoid any possibility of retinal burns. Short ultra
2011-03-12
determine (1) the ability of Megalopta to approach and land on its nest entrance at night (using high-speed filming in bright infrared light), (2...lined with black-and-white patterns and filming their flight trajectories from below in infrared light), and (3) whether Megalopta uses...at the end of a flight tunnel so that we could record both the approach and the final landing phase (Figure 1). The approach was filmed over a
2006-05-01
tubes utilizing thin- filmed technology allowing for a higher SNR, and the F4949G goggles were tested. Twelve participants tested each goggle under six...LogMAR Visual Acuity as a Function of Illumination, Contrast, and NVG ........ 37 Repeated Measures Within-Subjects Analysis of Variance...auto-gated power supply and thin- filmed technology. The Pinnacle’sTM thin- filmed technology gave the image intensifier tube an increase in the signal-to
The Visioceilometer: A Portable Visibility and Cloud Ceiling Height Lidar.
1982-01-01
Artillery School ATTN: STEDP-MT-DA-L ATTN: ATSF- CF -R (CPT James M. Watson) Dugway, UT 84022 Fort Sill, OK 73503 Commander Commandant US Army Dugway Proving...Commandant US Army Dugway Proving Ground US Army Field Artillery School ATTN: STEDP-MT-DA-T (Mr. John Trethewey) ATTN: ATSF- CF -R Dugway, UT 84022 Fort...Base, VA 23655 Fort !elvoir, VA 22060 Commander Director US Army INSCOM/Quest Research Corporation US Army Night Vision & ATTN: Mr. Donald Wilmot
Enhanced Night Vision Via a Combination of Poisson Interpolation and Machine Learning
2006-02-01
of 0-255, they are mostly similar. The right plot shows a family of m(x, ψ) curves of ψ=2 (the most linear) through ψ=1024 (the most curved ...complicating low-light imaging. Nayar and Branzoi [04] later suggested a second variant using a DLP micromirror array to modulate the exposure, via time...255, they are mostly similar. The right plot shows a family of m(x, ψ) curves of ψ=2 (the most linear) through ψ=1024 (the most curved
Observations of Infantry Courses: Implications for Land Warrior (LW) Training.
2000-01-01
PAQ -13 TWS and M68 CCO are not as prevalent in the force, as they are being fielded currently. Some units have prototype bore sight devices. The video...advanced infantry marksmanship (AIM) training using the AN/ PAQ -4C aiming light and the AN/PVS-7B/D or AN/PVS-14 night vision goggles (NVGs), but...the AN/ PAQ -4C infrared aiming light (IAL), the AN/PEQ-2A target pointer illuminator/aiming light (TPIAL), the video camera (now called the
2010-04-07
Commercialization Pilot Programs – Portable Fuel Analyzer – Non-woven FR Materials – Automatic Test Equipment – Night Vision Fusion • Significant efforts – Sensing...contract with the government". Advertising material , commercial item offer, or contribution, as defined in FAR 15.601 shall not be considered to...systems through the entire lifecycle. Our portfolio includes; •Individual & crew-served weapons ranging from 9 mm handguns to 87mm mortar systems
Software Interface Assessment of the Centralized Aviation Flight Records System (CAFRS) 4.0
2015-05-01
administrator based on the role of the user needing the permission. Within CAFRS, some permissions are grouped into common roles based on job...simplify. Ex: “Compl RL3 ref tng – Designated RL2 D/N, RL3 Night Vision Goggles (NVG)”. • Once entry is made on 7122 initial and signed and remark... designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an official endorsement or approval of the use
1997-06-01
made based on a learning mechanism. Traditional statistical regression and neural network approaches offer some utility, but suffer from practical...Columbus, OH. Kraiger, K., Ford, J. K., & Salas, E. (1993). Application of cognitive, skill- based , and affective theories of learning outcomes to new...and Feature Effects 151 Enhanced Spatial State Feedback for Night Vision Goggle Displays 159 Statistical Network Applications of Decision Aiding for
An Advanced 500-MHZ-Bandwidth Fiber-Optic Signal Link for EMP and General Laboratory Applications.
1981-07-01
EVALUATION DIR DEPT OF THE ARMY REDSTONE ARSENAL, AL 35809 ATTN STEWS -CE, COMMUNICATIONS/ ELEC OFFICE DIRECTOR ATTN STEWS -NR, NATIONAL RANGE NIGHT...VISION & ELECTRO-OPTICS LABORATORY OPERATIONS DIR ATTN DELNV-EO, E-O DEVICES DIV ATTN STEWS -ID, INSTRUMENTATION DIR FORT BELVOIR, VA 22060 ATTN STEWS -ID...22900 ATTN WHITTAKER, D., 22900 SPECTRONICS ATTN LAMB , R. C., 22900 ATTN L. STEWART ATTN OLDHAM, T. R., 2300 ATTN MR. SHAUNFIELD ATTN KEHS, A., 22300
Topographic Mapping of Residual Vision by Computer
ERIC Educational Resources Information Center
MacKeben, Manfred
2008-01-01
Many persons with low vision have diseases that damage the retina only in selected areas, which can lead to scotomas (blind spots) in perception. The most frequent of these diseases is age-related macular degeneration (AMD), in which foveal vision is often impaired by a central scotoma that impairs vision of fine detail and causes problems with…
Analysis of circadian properties and healthy levels of blue light from smartphones at night.
Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag
2015-06-18
This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display.
Classification Objects, Ideal Observers & Generative Models
ERIC Educational Resources Information Center
Olman, Cheryl; Kersten, Daniel
2004-01-01
A successful vision system must solve the problem of deriving geometrical information about three-dimensional objects from two-dimensional photometric input. The human visual system solves this problem with remarkable efficiency, and one challenge in vision research is to understand how neural representations of objects are formed and what visual…
Artificial light at night advances avian reproductive physiology
Dominoni, Davide; Quetting, Michael; Partecke, Jesko
2013-01-01
Artificial light at night is a rapidly increasing phenomenon and it is presumed to have global implications. Light at night has been associated with health problems in humans as a consequence of altered biological rhythms. Effects on wild animals have been less investigated, but light at night has often been assumed to affect seasonal cycles of urban dwellers. Using light loggers attached to free-living European blackbirds (Turdus merula), we first measured light intensity at night which forest and city birds are subjected to in the wild. Then we used these measurements to test for the effect of light at night on timing of reproductive physiology. Captive city and forest blackbirds were exposed to either dark nights or very low light intensities at night (0.3 lux). Birds exposed to light at night developed their reproductive system up to one month earlier, and also moulted earlier, than birds kept under dark nights. Furthermore, city birds responded differently than forest individuals to the light at night treatment, suggesting that urbanization can alter the physiological phenotype of songbirds. Our results emphasize the impact of human-induced lighting on the ecology of millions of animals living in cities and call for an understanding of the fitness consequences of light pollution. PMID:23407836
Fixed or Rotating Night Shift Work Undertaken by Women: Implications for Fertility and Miscarriage.
Fernandez, Renae C; Marino, Jennifer L; Varcoe, Tamara J; Davis, Scott; Moran, Lisa J; Rumbold, Alice R; Brown, Hannah M; Whitrow, Melissa J; Davies, Michael J; Moore, Vivienne M
2016-03-01
This review summarizes the evidence concerning effects of night shift work on women's reproductive health, specifically difficulty in conceiving and miscarriage. We distinguish between fixed night shift and rotating night shift, as the population subgroups exposed, the social and biological mechanisms, and the magnitude of effects are likely to differ; of note, women working fixed night shift are known to have high tolerance for this schedule. We identified two relevant systematic reviews with meta-analyses and five additional studies. Night shift work may give rise to menstrual cycle disturbances, but effect sizes are imprecise. Endometriosis may be elevated in night shift workers, but evidence is only preliminary. Adequate data are lacking to assess associations between night shift work and infertility or time to pregnancy. The weight of evidence begins to point to working at night, whether in fixed or rotating shifts, as a risk factor for miscarriage. There are many methodological problems with this literature, with substantial variation in the definitions of night shift and schedule types making comparisons between studies difficult and pooling across studies questionable. Nevertheless, there appears to be grounds for caution and counselling where women have concerns about night shift work and their reproductive health. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Non-Rigid Structure Estimation in Trajectory Space from Monocular Vision
Wang, Yaming; Tong, Lingling; Jiang, Mingfeng; Zheng, Junbao
2015-01-01
In this paper, the problem of non-rigid structure estimation in trajectory space from monocular vision is investigated. Similar to the Point Trajectory Approach (PTA), based on characteristic points’ trajectories described by a predefined Discrete Cosine Transform (DCT) basis, the structure matrix was also calculated by using a factorization method. To further optimize the non-rigid structure estimation from monocular vision, the rank minimization problem about structure matrix is proposed to implement the non-rigid structure estimation by introducing the basic low-rank condition. Moreover, the Accelerated Proximal Gradient (APG) algorithm is proposed to solve the rank minimization problem, and the initial structure matrix calculated by the PTA method is optimized. The APG algorithm can converge to efficient solutions quickly and lessen the reconstruction error obviously. The reconstruction results of real image sequences indicate that the proposed approach runs reliably, and effectively improves the accuracy of non-rigid structure estimation from monocular vision. PMID:26473863
Perry, George H; Martin, Robert D; Verrelli, Brian C
2007-09-01
While color vision perception is thought to be adaptively correlated with foraging efficiency for diurnal mammals, those that forage exclusively at night may not need color vision nor have the capacity for it. Indeed, although the basic condition for mammals is dichromacy, diverse nocturnal mammals have only monochromatic vision, resulting from functional loss of the short-wavelength sensitive opsin gene. However, many nocturnal primates maintain intact two opsin genes and thus have dichromatic capacity. The evolutionary significance of this surprising observation has not yet been elucidated. We used a molecular population genetics approach to test evolutionary hypotheses for the two intact opsin genes of the fully nocturnal aye-aye (Daubentonia madagascariensis), a highly unusual and endangered Madagascar primate. No evidence of gene degradation in either opsin gene was observed for any of 8 aye-aye individuals examined. Furthermore, levels of nucleotide diversity for opsin gene functional sites were lower than those for 15 neutrally evolving intergenic regions (>25 kb in total), which is consistent with a history of purifying selection on aye-aye opsin genes. The most likely explanation for these findings is that dichromacy is advantageous for aye-ayes despite their nocturnal activity pattern. We speculate that dichromatic nocturnal primates may be able to perceive color while foraging under moonlight conditions, and suggest that behavioral and ecological comparisons among dichromatic and monochromatic nocturnal primates will help to elucidate the specific activities for which color vision perception is advantageous.
Mertens, H W; Milburn, N J; Collins, W E
2000-12-01
Two practical color vision tests were developed and validated for use in screening Air Traffic Control Specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulation of color-coded materials from the most demanding, safety-critical color task performed in each type of facility. The tests were evaluated using 106 subjects with normal color vision and 85 with color vision deficiency. The en route center test, named the Flight Progress Strips Test (FPST), required the identification of critical red/black coding in computer printing and handwriting on flight progress strips. The terminal option test, named the Aviation Lights Test (ALT), simulated red/green/white aircraft lights that must be identified in night ATC tower operations. Color-coding is a non-redundant source of safety-critical information in both tasks. The FPST was validated by direct comparison of responses to strip reproductions with responses to the original flight progress strips and a set of strips selected independently. Validity was high; Kappa = 0.91 with original strips as the validation criterion and 0.86 with different strips. The light point stimuli of the ALT were validated physically with a spectroradiometer. The reliabilities of the FPST and ALT were estimated with Chronbach's alpha as 0.93 and 0.98, respectively. The high job-relevance, validity, and reliability of these tests increases the effectiveness and fairness of ATCS color vision testing.
Lightness modification of color image for protanopia and deuteranopia
NASA Astrophysics Data System (ADS)
Tanaka, Go; Suetake, Noriaki; Uchino, Eiji
2010-01-01
In multimedia content, colors play important roles in conveying visual information. However, color information cannot always be perceived uniformly by all people. People with a color vision deficiency, such as dichromacy, cannot recognize and distinguish certain color combinations. In this paper, an effective lightness modification method, which enables barrier-free color vision for people with dichromacy, especially protanopia or deuteranopia, while preserving the color information in the original image for people with standard color vision, is proposed. In the proposed method, an optimization problem concerning lightness components is first defined by considering color differences in an input image. Then a perceptible and comprehensible color image for both protanopes and viewers with no color vision deficiency or both deuteranopes and viewers with no color vision deficiency is obtained by solving the optimization problem. Through experiments, the effectiveness of the proposed method is illustrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, T.L.; Morisseau, D.; Murphy, N.M.
1995-04-01
The Nuclear Regulatory Commission`s (NRC) Headquarters Operations Officers (HOOs) receive and respond to events reported in the nuclear industry on a 24-hour basis. The HOOs have reported reduced alertness on the night shift, leading to a potential deterioration in their on-shift cognitive performance during the early morning hours. For some HOOs, maladaptation to the night shift was also reported to be the principal cause of: (a) reduced alertness during the commute to and from work, (b) poor sleep quality, and (c) personal lifestyle problems. ShiftWork Systems, Inc. (SWS) designed and installed a Circadian Lighting System (CLS) at both the Bethesdamore » and Rockville HOO stations with the goal of facilitating the HOOs physiological adjustment to their night shift schedules. The data indicate the following findings: less subjective fatigue on night shifts; improved night shift alertness and mental performance; higher HOO confidence in their ability to assess event reports; longer, deeper and more restorative day sleep after night duty shifts; swifter adaptation to night work; and a safer commute, particularly for those with extensive drives.« less
Quaternions in computer vision and robotics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pervin, E.; Webb, J.A.
1982-01-01
Computer vision and robotics suffer from not having good tools for manipulating three-dimensional objects. Vectors, coordinate geometry, and trigonometry all have deficiencies. Quaternions can be used to solve many of these problems. Many properties of quaternions that are relevant to computer vision and robotics are developed. Examples are given showing how quaternions can be used to simplify derivations in computer vision and robotics.
Modelling night-time ecosystem respiration by a constrained source optimization method
Chun-Tai Lai; Gabriel Katul; John Butnor; David Ellsworth; Ram Oren
2002-01-01
One of the main challenges to quantifying ecosystem carbon budgets is properly quantifying the magnitude of night-time ecosystem respiration. Inverse Lagrangian dispersion analysis provides a promising approach to addressing such a problem when measured mean CO2 concentration profiles and nocturnal velocity statistics are available. An inverse...
Reliable vision-guided grasping
NASA Technical Reports Server (NTRS)
Nicewarner, Keith E.; Kelley, Robert B.
1992-01-01
Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.
Problems with vision associated with limitations or avoidance of driving in older populations.
Satariano, William A; MacLeod, Kara E; Cohn, Theodore E; Ragland, David R
2004-09-01
This report examines the role of (a) disease processes affecting vision, (b) reported troubles with vision, (c) physical symptoms affecting the eyes, and (d) objective measures in reported driving limitation due to problems with eyesight among older drivers. Data for this study (N = 1,840) were obtained from participants in a community-based study of aging and physical performance in people age 55 or older in the city of Sonoma, California. Each of 16 visual conditions was assessed for impact on reported driving limitation due to eyesight by calculating a "risk" ratio. Then, prevalence of the condition was combined with the ratio to generate an attributable risk for that condition for vision-related limitations in driving. Each condition was significantly associated with reported limitations in driving due to eyesight. "Avoiding physical activity due to vision" (ratio = 3.4) and "trouble seeing steps up/down stairs" (ratio = 2.9) had the strongest association. However, "glasses/contacts required for driving" and "trouble with glare from sun/lights" had the highest attributable risks (35.8 and 29.4). The risk ratio is relevant for evaluating individuals; the attributable risk is relevant to planning countermeasures in populations. Addressing specific problems related to vision should substantially reduce driving limitations due to eyesight.
Reinforcement learning in computer vision
NASA Astrophysics Data System (ADS)
Bernstein, A. V.; Burnaev, E. V.
2018-04-01
Nowadays, machine learning has become one of the basic technologies used in solving various computer vision tasks such as feature detection, image segmentation, object recognition and tracking. In many applications, various complex systems such as robots are equipped with visual sensors from which they learn state of surrounding environment by solving corresponding computer vision tasks. Solutions of these tasks are used for making decisions about possible future actions. It is not surprising that when solving computer vision tasks we should take into account special aspects of their subsequent application in model-based predictive control. Reinforcement learning is one of modern machine learning technologies in which learning is carried out through interaction with the environment. In recent years, Reinforcement learning has been used both for solving such applied tasks as processing and analysis of visual information, and for solving specific computer vision problems such as filtering, extracting image features, localizing objects in scenes, and many others. The paper describes shortly the Reinforcement learning technology and its use for solving computer vision problems.
How Does My Child's Vision Affect His Reading?
ERIC Educational Resources Information Center
Eberly, Donald W.
Various eye problems and the effects they can have on children's reading abilities are explored in this pamphlet, which is one of a series designed to answer parents' questions about their children's reading development. Topics discussed are the demands on vision made by reading, problems that affect visual acuity (nearsightedness, farsightedness,…
Why Can't Johnny Read? The Abell Report. Volume 23, No.7
ERIC Educational Resources Information Center
Jacobson, Joan
2010-01-01
Baltimore's school-based vision-screening program may be leaving thousands of children with uncorrected eyesight problems. Vision screening in public schools is essential for students to learn, especially when low-income children face a high rate of eyesight problems and have poor access to health care. Left undetected and uncorrected, vision…
NASA Technical Reports Server (NTRS)
Lewandowski, Leon; Struckman, Keith
1994-01-01
Microwave Vision (MV), a concept originally developed in 1985, could play a significant role in the solution to robotic vision problems. Originally our Microwave Vision concept was based on a pattern matching approach employing computer based stored replica correlation processing. Artificial Neural Network (ANN) processor technology offers an attractive alternative to the correlation processing approach, namely the ability to learn and to adapt to changing environments. This paper describes the Microwave Vision concept, some initial ANN-MV experiments, and the design of an ANN-MV system that has led to a second patent disclosure in the robotic vision field.
The role of vision processing in prosthetic vision.
Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette
2012-01-01
Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.
Neck muscle activity in helicopter pilots: effect of position and helmet-mounted equipment.
Thuresson, Marcus; Ang, Björn; Linder, Jan; Harms-Ringdahl, Karin
2003-05-01
Helicopter pilots usually work in unfavorable ergonomic positions, often with bulky head-worn equipment during flying missions. The purpose of this study was to evaluate and compare immediate muscle response in the dorsal neck muscles to different positions with a variety of head-worn equipment. Fourteen healthy male helicopter pilots volunteered for this study. EMG activity in the upper and lower dorsal neck muscles and the trapezius muscle was measured in a laboratory situation for 5 s in different sitting positions (neutral, trunk inclined 20 degrees, neck flexed 20 degrees), including registration of a 30 degrees left and right rotation in every position; all measurements were performed while wearing a helmet, a helmet and night vision goggles (hNVG), and a helmet, night vision goggles, and counterweight (hCW), in random order. There was significant higher EMG activity in the upper neck with hNVG and hCW than with the helmet only when comparing the mean activity level of all positions. However, there was no significant difference in EMG activity between any variations of head-worn equipment when comparing activity levels during each position separately. In the upper and lower neck, respectively, there was significantly higher muscle activity during the ipsilateral rotated positions plus neck flexion and trunk inclination than in most other positions. The increased load caused by different positions seems to have a greater influence on muscle activity than the increased load of the head-worn equipment, which must be considered when designing helicopter work-places.
640x512 pixel InGaAs FPAs for short-wave infrared and visible light imaging
NASA Astrophysics Data System (ADS)
Shao, Xiumei; Yang, Bo; Huang, Songlei; Wei, Yang; Li, Xue; Zhu, Xianliang; Li, Tao; Chen, Yu; Gong, Haimei
2017-08-01
The spectral irradiance of moonlight and air glow is mainly in the wavelength region from visible to short-wave infrared (SWIR) band. The imaging over the wavelength range of visible to SWIR is of great significance for applications such as civil safety, night vision, and agricultural sorting. In this paper, 640×512 visible-SWIR InGaAs focal plane arrays (FPAs) were studied for night vision and SWIR imaging. A special epitaxial wafer structure with etch-stop layer was designed and developed. Planar-type 640×512 InGaAs detector arrays were fabricated. The photosensitive arrays were bonded with readout circuit through Indium bumps by flip-chip process. Then, the InP substrate was removed by mechanical thinning and chemical wet etching. The visible irradiance can reach InGaAs absorption layer and then to be detected. As a result, the detection spectrum of the InGaAs FPAs has been extended toward visible spectrum from 0.5μm to 1.7μm. The quantum efficiency is approximately 15% at 0.5μm, 30% at 0.7μm, 50% at 0.8μm, 90% at 1.55μm. The average peak detectivity is higher than 2×1012 cm·Hz1/2/W at room temperature with an integrated time of 10 ms. The Visible-SWIR InGaAs FPAs were applied to an imaging system for SWIR and visible light imaging.
Gellerfors, Mikael; Svensén, Christer; Linde, Joacim; Lossius, Hans Morten; Gryth, Dan
2015-09-01
Securing the airway by endotracheal intubation (ETI) is a key issue in prehospital critical care. Night vision goggles (NVG) are used by personnel operating in low-light environments. We examined the feasibility of an anesthesiologist performed ETI using NVG in a helicopter setting. Twelve anesthesiologists performed ETI on a manikin in an emergency room (ER) setting and two helicopter settings, with randomization to either rotary wing daylight (RW-D) or rotary wing in total darkness using binocular NVG (RW-NVG). Primary endpoint was intubation time. Secondary endpoints included success rate, Cormack-Lehane (CL) score, and subjective difficulty according to the Visual Analoge Scale (VAS). The median intubation time was shorter for the RW-D compared to the RW-NVG setting (16.5 seconds vs. 30.0 seconds; p = 0,03). We found no difference in median intubation time for the ER and RW-D settings (16.8 seconds vs. 16.5 seconds; p = 0.91). For all scenarios, success rate was 100%. CL and VAS varied between the ER setting (CL 1.8, VAS 2.8), RW-D setting (CL 2.0, VAS 3.0), and RW-NVG setting (CL 3.0, VAS 6.5). This study suggests that anesthesiologists successfully and quickly can perform ETI in a helicopter setting both in daylight and in darkness using binocular NVG, but with shorter intubation times in daylight. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
Spectral methods to detect surface mines
NASA Astrophysics Data System (ADS)
Winter, Edwin M.; Schatten Silvious, Miranda
2008-04-01
Over the past five years, advances have been made in the spectral detection of surface mines under minefield detection programs at the U. S. Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate (NVESD). The problem of detecting surface land mines ranges from the relatively simple, the detection of large anti-vehicle mines on bare soil, to the very difficult, the detection of anti-personnel mines in thick vegetation. While spatial and spectral approaches can be applied to the detection of surface mines, spatial-only detection requires many pixels-on-target such that the mine is actually imaged and shape-based features can be exploited. This method is unreliable in vegetated areas because only part of the mine may be exposed, while spectral detection is possible without the mine being resolved. At NVESD, hyperspectral and multi-spectral sensors throughout the reflection and thermal spectral regimes have been applied to the mine detection problem. Data has been collected on mines in forest and desert regions and algorithms have been developed both to detect the mines as anomalies and to detect the mines based on their spectral signature. In addition to the detection of individual mines, algorithms have been developed to exploit the similarities of mines in a minefield to improve their detection probability. In this paper, the types of spectral data collected over the past five years will be summarized along with the advances in algorithm development.
Fast and Accurate Poisson Denoising With Trainable Nonlinear Diffusion.
Feng, Wensen; Qiao, Peng; Chen, Yunjin; Wensen Feng; Peng Qiao; Yunjin Chen; Feng, Wensen; Chen, Yunjin; Qiao, Peng
2018-06-01
The degradation of the acquired signal by Poisson noise is a common problem for various imaging applications, such as medical imaging, night vision, and microscopy. Up to now, many state-of-the-art Poisson denoising techniques mainly concentrate on achieving utmost performance, with little consideration for the computation efficiency. Therefore, in this paper we aim to propose an efficient Poisson denoising model with both high computational efficiency and recovery quality. To this end, we exploit the newly developed trainable nonlinear reaction diffusion (TNRD) model which has proven an extremely fast image restoration approach with performance surpassing recent state-of-the-arts. However, the straightforward direct gradient descent employed in the original TNRD-based denoising task is not applicable in this paper. To solve this problem, we resort to the proximal gradient descent method. We retrain the model parameters, including the linear filters and influence functions by taking into account the Poisson noise statistics, and end up with a well-trained nonlinear diffusion model specialized for Poisson denoising. The trained model provides strongly competitive results against state-of-the-art approaches, meanwhile bearing the properties of simple structure and high efficiency. Furthermore, our proposed model comes along with an additional advantage, that the diffusion process is well-suited for parallel computation on graphics processing units (GPUs). For images of size , our GPU implementation takes less than 0.1 s to produce state-of-the-art Poisson denoising performance.
Riza, Nabeel A; La Torre, Juan Pablo; Amin, M Junaid
2016-06-13
Proposed and experimentally demonstrated is the CAOS-CMOS camera design that combines the coded access optical sensor (CAOS) imager platform with the CMOS multi-pixel optical sensor. The unique CAOS-CMOS camera engages the classic CMOS sensor light staring mode with the time-frequency-space agile pixel CAOS imager mode within one programmable optical unit to realize a high dynamic range imager for extreme light contrast conditions. The experimentally demonstrated CAOS-CMOS camera is built using a digital micromirror device, a silicon point-photo-detector with a variable gain amplifier, and a silicon CMOS sensor with a maximum rated 51.3 dB dynamic range. White light imaging of three different brightness simultaneously viewed targets, that is not possible by the CMOS sensor, is achieved by the CAOS-CMOS camera demonstrating an 82.06 dB dynamic range. Applications for the camera include industrial machine vision, welding, laser analysis, automotive, night vision, surveillance and multispectral military systems.
Military readiness: an exploration of the relationship between marksmanship and visual acuity.
Wells, Kenney H; Wagner, Heidi; Reich, Lewis N; Hardigan, Patrick C
2009-04-01
The United States military relies on visual acuity standards to assess enlistment induction and military occupational specialty eligibility, as well as to monitor soldiers' combat vision readiness. However, these vision standards are not evidence based and may not accurately reflect appropriate standards for military readiness or reflect a correlation between visual acuity and occupational performance. The aim of this study was to investigate the relationship between visual acuity and marksmanship performance using a single blind trial with the Engagement Skills Trainer 2000. Marksmanship performance was evaluated in 28 subjects under simulated day and night conditions with habitual spectacle prescription and contact lenses that created visual blur. Panel Poisson regression using an independent correlation structure revealed significant differences (p < 0.001) as visual acuity decreased from 20/25 to 20/50. We conclude that marksmanship performance decreases as visual acuity decreases. We believe that this relationship supports the use of a visual acuity requirement.
FELIN: tailored optronics and systems solutions for dismounted combat
NASA Astrophysics Data System (ADS)
Milcent, A. M.
2009-05-01
The FELIN French modernization program for dismounted combat provides the Armies with info-centric systems which dramatically enhance the performances of the soldier and the platoon. Sagem now has available a portfolio of various equipments, providing C4I, data and voice digital communication, and enhanced vision for day and night operations, through compact high performance electro-optics. The FELIN system provides the infantryman with a high-tech integrated and modular system which increases significantly their detection, recognition, identification capabilities, their situation awareness and information sharing, and this in any dismounted close combat situation. Among the key technologies used in this system, infrared and intensified vision provide a significant improvement in capability, observation performance and protection of the ground soldiers. This paper presents in detail the developed equipments, with an emphasis on lessons learned from the technical and operational feedback from dismounted close combat field tests.
NASA Astrophysics Data System (ADS)
Isik-Ercan, Zeynep; Kim, Beomjin; Nowak, Jeffrey
This research-in-progress hypothesizes that urban second graders can have an early understanding about the shape of Sun, Moon, and Earth, how day and night happens, and how Moon appears to change its shape by using three dimensional stereoscopic vision. The 3D stereoscopic vision system might be an effective way to teach subjects like astronomy that explains relationships among objects in space. Currently, Indiana state standards for science teaching do not suggest the teaching of these astronomical concepts explicitly before fourth grade. Yet, we expect our findings to indicate that students can learn these concepts earlier in their educational lives with the implementation of such technologies. We also project that these technologies could revolutionize when these concepts could be taught to children and expand the ways we think about children's cognitive capacities in understanding scientific concepts.
ERIC Educational Resources Information Center
Tucker, Laurel A.
2004-01-01
Adults with low vision who seek clinical low vision services need to be able to read (that is, to interpret or understand words, numbers, and symbols in print meaningfully). Reading difficulties that adults encounter during low vision therapy may be directly connected to a visual impairment or may be related to other reading problems, such as…
Haldin, Charlotte; Nymark, Soile; Aho, Ann-Christine; Koskelainen, Ari; Donner, Kristian
2009-05-06
Human vision is approximately 10 times less sensitive than toad vision on a cool night. Here, we investigate (1) how far differences in the capacity for temporal integration underlie such differences in sensitivity and (2) whether the response kinetics of the rod photoreceptors can explain temporal integration at the behavioral level. The toad was studied as a model that allows experimentation at different body temperatures. Sensitivity, integration time, and temporal accuracy of vision were measured psychophysically by recording snapping at worm dummies moving at different velocities. Rod photoresponses were studied by ERG recording across the isolated retina. In both types of experiments, the general timescale of vision was varied by using two temperatures, 15 and 25 degrees C. Behavioral integration times were 4.3 s at 15 degrees C and 0.9 s at 25 degrees C, and rod integration times were 4.2-4.3 s at 15 degrees C and 1.0-1.3 s at 25 degrees C. Maximal behavioral sensitivity was fivefold lower at 25 degrees C than at 15 degrees C, which can be accounted for by inability of the "warm" toads to integrate light over longer times than the rods. However, the long integration time at 15 degrees C, allowing high sensitivity, degraded the accuracy of snapping toward quickly moving worms. We conclude that temporal integration explains a considerable part of all variation in absolute visual sensitivity. The strong correlation between rods and behavior suggests that the integration time of dark-adapted vision is set by rod phototransduction at the input to the visual system. This implies that there is an inexorable trade-off between temporal integration and resolution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morellas, Vassilios; Johnson, Andrew; Johnston, Chris
2006-07-01
Thermal imaging is rightfully a real-world technology proven to bring confidence to daytime, night-time and all weather security surveillance. Automatic image processing intrusion detection algorithms are also a real world technology proven to bring confidence to system surveillance security solutions. Together, day, night and all weather video imagery sensors and automated intrusion detection software systems create the real power to protect early against crime, providing real-time global homeland protection, rather than simply being able to monitor and record activities for post event analysis. These solutions, whether providing automatic security system surveillance at airports (to automatically detect unauthorized aircraft takeoff andmore » landing activities) or at high risk private, public or government facilities (to automatically detect unauthorized people or vehicle intrusion activities) are on the move to provide end users the power to protect people, capital equipment and intellectual property against acts of vandalism and terrorism. As with any technology, infrared sensors and automatic image intrusion detection systems for global homeland security protection have clear technological strengths and limitations compared to other more common day and night vision technologies or more traditional manual man-in-the-loop intrusion detection security systems. This paper addresses these strength and limitation capabilities. False Alarm (FAR) and False Positive Rate (FPR) is an example of some of the key customer system acceptability metrics and Noise Equivalent Temperature Difference (NETD) and Minimum Resolvable Temperature are examples of some of the sensor level performance acceptability metrics. (authors)« less
ERIC Educational Resources Information Center
Kendall, Richard
1988-01-01
The art of Edgar Degas is discussed in relation to his impaired vision, including amblyopia, later blindness in one eye, corneal scarring, and photophobia. Examined are ways in which Degas compensated for vision problems, and dominant themes of his art such as the process of perception and spots of brilliant light. (Author/JDD)
A Lens on Learning: Early Vision Screening Can Set Children on the Path to Achievement.
ERIC Educational Resources Information Center
Black, Susan
2002-01-01
Discusses student learning difficulties linked to visual disorders such as dyslexia and amblyopia, problems associated with current school vision-screening procedures, and recommendations to improve preschool and in-school vision-screening practices with an emphasis on early, regular, and comprehensive eye examinations. (PKP)
NASA Astrophysics Data System (ADS)
Isik-Ercan, Zeynep; Zeynep Inan, Hatice; Nowak, Jeffrey A.; Kim, Beomjin
2014-01-01
This qualitative case study describes (a) the ways 3D visualization, coupled with other science and literacy experiences, supported young children's first exploration of the Earth-Sun-Moon system and (b) the perspectives of classroom teachers and children on using 3D visualization. We created three interactive 3D software modules that simulate day and night, Moon phases and seasons. These modules were used in a science and literacy unit for 35 second graders at an urban elementary school in Midwestern USA. Data included pre- and post-interviews, audio-taped lessons and classroom observations. Post-interviews demonstrated that children's knowledge of the shapes and the movements of the Earth and Moon, alternation of day and night, the occurrence of the seasons, and Moon's changing appearance increased. Second graders reported that they enjoyed expanding their knowledge through hands-on experiences; through its reality effect, 3D visualization enabled them to observe the space objects that move in the virtual space. The teachers noted that 3D visualization stimulated children's interest in space and that using 3D visualization in combination with other teaching methods-literacy experiences, videos and photos, simulations, discussions, and presentations-supported student learning. The teachers and the students still experienced challenges using 3D visualization due to technical problems with 3D vision and time constraints. We conclude that 3D visualization offers hands-on experiences for challenging science concepts and may support young children's ability to view phenomena that would typically be observed through direct, long-term observations in outer space. Results imply a reconsideration of assumed capabilities of young children to understand astronomical phenomena.
Physiological and Psychological Aspects of Night and Shift Work.
ERIC Educational Resources Information Center
Wojtczak-Jaroszowa, Jadwiga
Results of physiological and psychological studies related to night and shift work are reviewed from the standpoint of their possible use by industry in understanding the problems of shift work and finding solutions. (New research data that has appeared since original preparation of the manuscript is presented in a three-part addendum with…
Machine vision for various manipulation tasks
NASA Astrophysics Data System (ADS)
Domae, Yukiyasu
2017-03-01
Bin-picking, re-grasping, pick-and-place, kitting, etc. There are many manipulation tasks in the fields of automation of factory, warehouse and so on. The main problem of the automation is that the target objects (items/parts) have various shapes, weights and surface materials. In my talk, I will show latest machine vision systems and algorithms against the problem.
Das Ende der Nacht [The End of the Night (2nd enlarged ed.)
NASA Astrophysics Data System (ADS)
Posch, Thomas; Hölker, Franz; Uhlmann, Thomas; Freyhoff, Anja
2013-09-01
We provide provide an overview of the history of lighting and of the problems arising from artificial lighting. The book covers the following topics: A brief history of light (ch. 1); night and light in cultural history (ch. 2); light pollution in central Europe (ch. 3); Moths and artificial lights (ch. 4); Artificial lighting and birds (ch. 5); Ocean turtles as victims of beach lighting (ch. 6); Moon light as a zeitgeber for the marine fauna (ch. 7); the influence of artificial light at night on freshwater ecology (ch. 8); artificial light and human health (ch. 9); the loss of the night in a 24 hours society (ch. 10).
Visual function of police officers who have undergone refractive surgery.
Hovis, Jeffery K; Ramaswamy, Shankaran
2006-11-01
The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.
Near real-time, on-the-move software PED using VPEF
NASA Astrophysics Data System (ADS)
Green, Kevin; Geyer, Chris; Burnette, Chris; Agarwal, Sanjeev; Swett, Bruce; Phan, Chung; Deterline, Diane
2015-05-01
The scope of the Micro-Cloud for Operational, Vehicle-Based EO-IR Reconnaissance System (MOVERS) development effort, managed by the Night Vision and Electronic Sensors Directorate (NVESD), is to develop, integrate, and demonstrate new sensor technologies and algorithms that improve improvised device/mine detection using efficient and effective exploitation and fusion of sensor data and target cues from existing and future Route Clearance Package (RCP) sensor systems. Unfortunately, the majority of forward looking Full Motion Video (FMV) and computer vision processing, exploitation, and dissemination (PED) algorithms are often developed using proprietary, incompatible software. This makes the insertion of new algorithms difficult due to the lack of standardized processing chains. In order to overcome these limitations, EOIR developed the Government off-the-shelf (GOTS) Video Processing and Exploitation Framework (VPEF) to be able to provide standardized interfaces (e.g., input/output video formats, sensor metadata, and detected objects) for exploitation software and to rapidly integrate and test computer vision algorithms. EOIR developed a vehicle-based computing framework within the MOVERS and integrated it with VPEF. VPEF was further enhanced for automated processing, detection, and publishing of detections in near real-time, thus improving the efficiency and effectiveness of RCP sensor systems.
Multiple-modality program for standoff detection of roadside hazards
NASA Astrophysics Data System (ADS)
Williams, Kathryn; Middleton, Seth; Close, Ryan; Luke, Robert H.; Suri, Rajiv
2016-05-01
The U.S. Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate (NVESD) is executing a program to assess the performance of a variety of sensor modalities for standoff detection of roadside explosive hazards. The program objective is to identify an optimal sensor or combination of fused sensors to incorporate with autonomous detection algorithms into a system of systems for use in future route clearance operations. This paper provides an overview of the program, including a description of the sensors under consideration, sensor test events, and ongoing data analysis.
NASA Astrophysics Data System (ADS)
Zelazny, Amy; Benson, Robert; Deegan, John; Walsh, Ken; Schmidt, W. David; Howe, Russell
2013-06-01
We describe the benefits to camera system SWaP-C associated with the use of aspheric molded glasses and optical polymers in the design and manufacture of optical components and elements. Both camera objectives and display eyepieces, typical for night vision man-portable EO/IR systems, are explored. We discuss optical trade-offs, system performance, and cost reductions associated with this approach in both visible and non-visible wavebands, specifically NIR and LWIR. Example optical models are presented, studied, and traded using this approach.
Physics-Based Stimulation for Night Vision Goggle Simulation
2006-11-01
a CRT display system can produce darker black level than displays based on digital light processing (DLP) or liquid crystal technologies. It should...The general form of the bucket equation for any gun (color) is as follows: (3) n n n n r MnRp f MxR MnR ⎛ ⎞− = ⎜ ⎟−⎝ ⎠ Equation 3 General...simulate rendering approach, we began by testing the bucket rendering approach already utilized by SensorHost: (10) n n n n r MnRp f MxR MnR
Fabrication of Advanced Thermoelectric Materials by Hierarchical Nanovoid Generation
NASA Technical Reports Server (NTRS)
Park, Yeonjoon (Inventor); Elliott, James R. (Inventor); Stoakley, Diane M. (Inventor); Chu, Sang-Hyon (Inventor); King, Glen C. (Inventor); Kim, Jae-Woo (Inventor); Choi, Sang Hyouk (Inventor); Lillehei, Peter T. (Inventor)
2011-01-01
A novel method to prepare an advanced thermoelectric material has hierarchical structures embedded with nanometer-sized voids which are key to enhancement of the thermoelectric performance. Solution-based thin film deposition technique enables preparation of stable film of thermoelectric material and void generator (voigen). A subsequent thermal process creates hierarchical nanovoid structure inside the thermoelectric material. Potential application areas of this advanced thermoelectric material with nanovoid structure are commercial applications (electronics cooling), medical and scientific applications (biological analysis device, medical imaging systems), telecommunications, and defense and military applications (night vision equipments).
1982-11-01
McAreavy Advanced Attack Helicopter, ATTN;. DRCPM-AAH Target Acquisition Designation System/Pilot Night Vision System, ATTN; nRCPM-AAH-TP USA Aviation...Arabian National Guard Modernization Program, ATTN: DRCPM-NG USA Communications-Electronics Command, ATTN: DRCPM-GARS SMOKE/OBSCURANTS, ATTN; DRCPM...LI~ C.’ t4 oo C) ON )~ al C a;- n enD 9- C% L In C) c! o c5 4o Lo’ w - 0) ’. co L t~0 0l C)O~L 1,.- ool *.- # 0 t; -, j CC -J tmj Li -00 0 0 C 0*J
NASA Astrophysics Data System (ADS)
Xu, Junfeng; Li, Weile; He, Bo; Wang, Haowei; Song, Yong; Yang, Shengyi; Ni, Guoqiang
2018-01-01
Infrared detecting and display device (IR-DDD) is a newly developed optical up-conversion device that integrates the light-emitting diode (LED) onto the infrared (IR) photo-detector, in order to convert IR light into the carriers photo-generated in detection materials and inject them into LED to emit visible light. This IR-DDD can achieve the direct up-conversion from IR ray to visible light, showing the considerable potential in night-vision application. This paper attempts a review of its working principle and current research progresses.
Summary of ARI Research on Remotely Monitored Sensors
1980-07-01
I NAVY PFRSONNEL R AND 0 CENTER/ I US ARMY AVN ENbINEERING FLIGHT ACTIVIIY ATTN8 SAVTE- TD SoFc OF NAVAL RESEARCH PERSONNEL AND TRAINING RESEARCH...LABS ATTN: LTL- TD -S I USA MORILITY EWUIPMENT R AND 0 COMO ATTNS ODMUE-TO I NIGHT VISION LAH ATTN: UHSEL-NV-SUU I USA TRAINING BUAHD I USA HUMAN...I PURDUE UNIV DLPT OF PSYCMOLOGICAL SCIE.NCES 1 05A MOHILITY EWI,1PMENT w AND 0 LUMMANL) ATTNt URDME-1rG IHQ . USA MDW ATTN; ANPE-vE It D A US ARMY
Human Factors and Safety Considerations of Night Vision Systems Flight Using Thermal Imaging Systems
1990-04-01
s4 tank with engine, drive playa that are twit very daIrk in the kcast brightest wheel-, and eXhSAus at temprrAtures between M5 anid Warea IvPKlly...be presented to the pilot on a miniature (1- sources, when viewed through the combiner, degra- inch diameter) cathodec ray tube (CRT) in the de the...performance. Also. flme Ccas Affect the display’s performance as well. The see-through chrsctcrisics of the display permit de Unlike sytcms using the
Vision and Oral Health Needs of Individuals with Intellectual Disability
ERIC Educational Resources Information Center
Owens, Pamela L.; Kerker, Bonnie D.; Zigler, Edward; Horwitz, Sarah M.
2006-01-01
Over the past 20 years, there has been an increased emphasis on health promotion, including prevention activities related to vision and oral health, for the general population, but not for individuals with intellectual disability (ID). This review explores what is known about the prevalence of vision problems and oral health conditions among…
1985-01-01
The NASA imaging processing technology, an advanced computer technique to enhance images sent to Earth in digital form by distant spacecraft, helped develop a new vision screening process. The Ocular Vision Screening system, an important step in preventing vision impairment, is a portable device designed especially to detect eye problems in children through the analysis of retinal reflexes.
Access to Microsoft Windows 95 for Persons with Low Vision: An Overview.
ERIC Educational Resources Information Center
Shragai, Y.
1995-01-01
This article examines Windows 95, pointing out differences and improvements from Windows 3.1 for persons with low vision. Windows 95 is seen as providing substantially greater accessibility than Windows 3.1, though the graphical user interface may still pose serious problems for some users with low vision. (DB)
Robust Spatial Autoregressive Modeling for Hardwood Log Inspection
Dongping Zhu; A.A. Beex
1994-01-01
We explore the application of a stochastic texture modeling method toward a machine vision system for log inspection in the forest products industry. This machine vision system uses computerized tomography (CT) imaging to locate and identify internal defects in hardwood logs. The application of CT to such industrial vision problems requires efficient and robust image...
Vision rehabilitation in the case of blindness.
Veraart, Claude; Duret, Florence; Brelén, Marten; Oozeer, Medhy; Delbeke, Jean
2004-09-01
This article examines the various vision rehabilitation procedures that are available for early and late blindness. Depending on the pathology involved, several vision rehabilitation procedures exist, or are in development. Visual aids are available for low vision individuals, as are sensory aids for blind persons. Most noninvasive sensory substitution prostheses as well as implanted visual prostheses in development are reviewed. Issues dealing with vision rehabilitation are also discussed, such as problems of biocompatibility, electrical safety, psychosocial aspects, and ethics. Basic studies devoted to vision rehabilitation such as simulation in mathematical models and simulation of artificial vision are also presented. Finally, the importance of accurate rehabilitation assessment is addressed, and tentative market figures are given.
Sleep Problems in Individuals with Angelman Syndrome
ERIC Educational Resources Information Center
Didden, Robert; Korzilius, Hubert; Smits, Marcel G.; Curfs, Leopold M. G.
2004-01-01
Prevalence of severe sleep problems and its association with other variables were investigated with 109 individuals who have Angelman syndrome. Severe settling problems, frequent night waking, and early waking were found in 2%, 37%, and 10% of the individuals, respectively. Sleep problems were persistent in this sample. No statistically…
Analysis of circadian properties and healthy levels of blue light from smartphones at night
Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag
2015-01-01
This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display. PMID:26085126
Analysis of circadian properties and healthy levels of blue light from smartphones at night
NASA Astrophysics Data System (ADS)
Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag
2015-06-01
This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display.
Artificial intelligence, expert systems, computer vision, and natural language processing
NASA Technical Reports Server (NTRS)
Gevarter, W. B.
1984-01-01
An overview of artificial intelligence (AI), its core ingredients, and its applications is presented. The knowledge representation, logic, problem solving approaches, languages, and computers pertaining to AI are examined, and the state of the art in AI is reviewed. The use of AI in expert systems, computer vision, natural language processing, speech recognition and understanding, speech synthesis, problem solving, and planning is examined. Basic AI topics, including automation, search-oriented problem solving, knowledge representation, and computational logic, are discussed.
ERIC Educational Resources Information Center
Galperin, D.; Raviolo, A.
2015-01-01
This work analysed the evolution of day/night cycle conceptions held by students of different ages and teachers in the Patagonian region of Argentina. The research was based on drawings, written explanations and semi-structured individual interviews. The results showed that both teachers and students had significant comprehension problems. These…
ERIC Educational Resources Information Center
Glewwe, Paul; West, Kristine L.; Lee, Jongwook
2018-01-01
More than 20 percent of all school-aged children in the United States have vision problems, and low-income and minority children are disproportionately likely to have unmet vision care needs. Vision screening is common in U.S. schools, but it remains an open question whether screening alone is sufficient to improve student outcomes. We implemented…
Machine vision and appearance based learning
NASA Astrophysics Data System (ADS)
Bernstein, Alexander
2017-03-01
Smart algorithms are used in Machine vision to organize or extract high-level information from the available data. The resulted high-level understanding the content of images received from certain visual sensing system and belonged to an appearance space can be only a key first step in solving various specific tasks such as mobile robot navigation in uncertain environments, road detection in autonomous driving systems, etc. Appearance-based learning has become very popular in the field of machine vision. In general, the appearance of a scene is a function of the scene content, the lighting conditions, and the camera position. Mobile robots localization problem in machine learning framework via appearance space analysis is considered. This problem is reduced to certain regression on an appearance manifold problem, and newly regression on manifolds methods are used for its solution.
Palese, Alvisa; Basso, Felix; Del Negro, Elena; Achil, Illarj; Ferraresi, Annamaria; Morandini, Marzia; Moreale, Renzo; Mansutti, Irene
2017-05-01
Some nursing programmes offer night shifts for students while others do not, mainly due to the lack of evidence regarding their effectiveness on clinical learning. The principal aims of the study were to describe nursing students' perceptions and to explore conditions influencing effectiveness on learning processes during night shifts. An explanatory mixed-method study design composed of a cross-sectional study (primary method, first phase) followed by a descriptive phenomenological study design (secondary method, second phase) in 2015. Two bachelor of nursing degree programmes located in Northern Italy, three years in length and requiring night shifts for students starting in the second semester of the 1st year, were involved. First phase: all nursing students ending their last clinical placement of the academic year attended were eligible; 352 out the 370 participated. Second phase: a purposeful sample of nine students among those included in the first phase and who attended the highest amount of night shifts were interviewed. First phase: a questionnaire composed of closed and open-ended questions was adopted; data was analyzed through descriptive statistical methods. Second phase: an open-ended face-to-face audio-recorded interview was adopted and data was analyzed through content analysis. Findings from the quantitative phase, showed that students who attended night shifts reported satisfaction (44.7%) less frequently than those who attended only day shifts (55.9%). They also reported boredom (23.5%) significantly more often compared to day shift students (p=0001). Understanding of the nursing role and learning competence was significantly inferior among night shift students as compared to day shift students, while the perception of wasting time was significantly higher among night shift students compared to their counterparts. Night shift students performed nursing rounds (288; 98.2%), non-nursing tasks (247; 84.3%) and/or less often managed clinical problems (insomnia 37; 12.6% and disorientation/confusion 32; 10.9%). Findings from the qualitative phase showed night shifts are experienced by students as a "time potentially capable of generating clinical learning": learning is maximized when students play an active role, encounter patients' clinical problems and develop relationships with patients, caregivers and staff. Night shifts remains ambiguous from the students' perspective and their introduction in nursing education should be approached with care, considering the learning aims expected by students in their clinical placements and the education of clinical mentors education who should be capable of effectively involving students in the process of night care by avoiding non-nursing tasks. Copyright © 2017 Elsevier Ltd. All rights reserved.
... and lens of your eye helps you focus. Refractive errors are vision problems that happen when the shape ... cornea, or aging of the lens. Four common refractive errors are Myopia, or nearsightedness - clear vision close up ...
Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha
2008-01-01
In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.
Death of Darkness: Artificial Sky Brightness in the Anthropocene
NASA Astrophysics Data System (ADS)
Zender, C. S.
2016-12-01
Many species (including ours) need darkness to survive and thrive yet light pollution in the anthropocene has received scant attention in Earth System Models (ESMs). Anthropogenic aerosols can brighten background sky brightness and reduce the contrast between skylight and starlight. These are both aesthetic and health-related issues due to their accompanying disruption of circadian rhythms. We quantify aerosol contributions to light pollution using a single-column night sky model, NiteLite, suitable for implementation in ESMs. NiteLite accounts for physiologcal (photopic and scotopic vision, retinal diameter/age), anthropogenic (light and aerosol pollution properties), and natural (surface albedo, trace gases) effects on background brightness and threshold visibility. We find that stratospheric aerosol injection contemplated as a stop-gap measure to counter global warming would increase night-sky brightness by about 25%, and thus eliminate last pristine dark sky areas on Earth. Our results suggest that ESMs incorporate light pollution so that associated societal impacts can be better quantified and included in policy deliberations.
Passive IR polarization sensors: a new technology for mine detection
NASA Astrophysics Data System (ADS)
Barbour, Blair A.; Jones, Michael W.; Barnes, Howard B.; Lewis, Charles P.
1998-09-01
The problem of mine and minefield detection continues to provide a significant challenge to sensor systems. Although the various sensor technologies (infrared, ground penetrating radar, etc.) may excel in certain situations there does not exist a single sensor technology that can adequately detect mines in all conditions such as time of day, weather, buried or surface laid, etc. A truly robust mine detection system will likely require the fusion of data from multiple sensor technologies. The performance of these systems, however, will ultimately depend on the performance of the individual sensors. Infrared (IR) polarimetry is a new and innovative sensor technology that adds substantial capabilities to the detection of mines. IR polarimetry improves on basic IR imaging by providing improved spatial resolution of the target, an inherent ability to suppress clutter, and the capability for zero (Delta) T imaging. Nichols Research Corporation (Nichols) is currently evaluating the effectiveness of IR polarization for mine detection. This study is partially funded by the U.S. Army Night Vision & Electronic Sensors Directorate (NVESD). The goal of the study is to demonstrate, through phenomenology studies and limited field trials, that IR polarizaton outperforms conventional IR imaging in the mine detection arena.
Novel Descattering Approach for Stereo Vision in Dense Suspended Scatterer Environments
Nguyen, Chanh D. Tr.; Park, Jihyuk; Cho, Kyeong-Yong; Kim, Kyung-Soo; Kim, Soohyun
2017-01-01
In this paper, we propose a model-based scattering removal method for stereo vision for robot manipulation in indoor scattering media where the commonly used ranging sensors are unable to work. Stereo vision is an inherently ill-posed and challenging problem. It is even more difficult in the case of images of dense fog or dense steam scenes illuminated by active light sources. Images taken in such environments suffer attenuation of object radiance and scattering of the active light sources. To solve this problem, we first derive the imaging model for images taken in a dense scattering medium with a single active illumination close to the cameras. Based on this physical model, the non-uniform backscattering signal is efficiently removed. The descattered images are then utilized as the input images of stereo vision. The performance of the method is evaluated based on the quality of the depth map from stereo vision. We also demonstrate the effectiveness of the proposed method by carrying out the real robot manipulation task. PMID:28629139
Enhanced computer vision with Microsoft Kinect sensor: a review.
Han, Jungong; Shao, Ling; Xu, Dong; Shotton, Jamie
2013-10-01
With the invention of the low-cost Microsoft Kinect sensor, high-resolution depth and visual (RGB) sensing has become available for widespread use. The complementary nature of the depth and visual information provided by the Kinect sensor opens up new opportunities to solve fundamental problems in computer vision. This paper presents a comprehensive review of recent Kinect-based computer vision algorithms and applications. The reviewed approaches are classified according to the type of vision problems that can be addressed or enhanced by means of the Kinect sensor. The covered topics include preprocessing, object tracking and recognition, human activity analysis, hand gesture analysis, and indoor 3-D mapping. For each category of methods, we outline their main algorithmic contributions and summarize their advantages/differences compared to their RGB counterparts. Finally, we give an overview of the challenges in this field and future research trends. This paper is expected to serve as a tutorial and source of references for Kinect-based computer vision researchers.
3-D Signal Processing in a Computer Vision System
Dongping Zhu; Richard W. Conners; Philip A. Araman
1991-01-01
This paper discusses the problem of 3-dimensional image filtering in a computer vision system that would locate and identify internal structural failure. In particular, a 2-dimensional adaptive filter proposed by Unser has been extended to 3-dimension. In conjunction with segmentation and labeling, the new filter has been used in the computer vision system to...
A multidisciplinary approach to solving computer related vision problems.
Long, Jennifer; Helland, Magne
2012-09-01
This paper proposes a multidisciplinary approach to solving computer related vision issues by including optometry as a part of the problem-solving team. Computer workstation design is increasing in complexity. There are at least ten different professions who contribute to workstation design or who provide advice to improve worker comfort, safety and efficiency. Optometrists have a role identifying and solving computer-related vision issues and in prescribing appropriate optical devices. However, it is possible that advice given by optometrists to improve visual comfort may conflict with other requirements and demands within the workplace. A multidisciplinary approach has been advocated for solving computer related vision issues. There are opportunities for optometrists to collaborate with ergonomists, who coordinate information from physical, cognitive and organisational disciplines to enact holistic solutions to problems. This paper proposes a model of collaboration and examples of successful partnerships at a number of professional levels including individual relationships between optometrists and ergonomists when they have mutual clients/patients, in undergraduate and postgraduate education and in research. There is also scope for dialogue between optometry and ergonomics professional associations. A multidisciplinary approach offers the opportunity to solve vision related computer issues in a cohesive, rather than fragmented way. Further exploration is required to understand the barriers to these professional relationships. © 2012 The College of Optometrists.
Initial test of MITA/DIMM with an operational CBP system
NASA Astrophysics Data System (ADS)
Baldwin, Kevin; Hanna, Randall; Brown, Andrea; Brown, David; Moyer, Steven; Hixson, Jonathan G.
2018-05-01
The MITA (Motion Imagery Task Analyzer) project was conceived by CBP OA (Customs and Border Protection - Office of Acquisition) and executed by JHU/APL (Johns Hopkins University/Applied Physics Laboratory) and CERDEC NVESD MSD (Communications and Electronics Research Development Engineering Command Night Vision and Electronic Sensors Directorate Modeling and Simulation Division). The intent was to develop an efficient methodology whereby imaging system performance could be quickly and objectively characterized in a field setting. The initial design, development, and testing spanned a period of approximately 18 months with the initial project coming to a conclusion after testing of the MITA system in June 2017 with a fielded CBP system. The NVESD contribution to MITA was thermally heated target resolution boards deployed to support a range close to the sensor and, when possible, at range with the targets of interest. JHU/APL developed a laser DIMM (Differential Image Motion Monitor) system designed to measure the optical turbulence present along the line of sight of the imaging system during the time of image collection. The imagery collected of the target board was processed to calculate the in situ system resolution. This in situ imaging system resolution and the time-correlated turbulence measured by the DIMM system were used in NV-IPM (Night Vision Integrated Performance Model) to calculate the theoretical imaging system performance. Overall, this proves the MITA concept feasible. However, MITA is still in the initial phases of development and requires further verification and validation to ensure accuracy and reliability of both the instrument and the imaging system performance predictions.
Demonstration of obstacle avoidance system (OASYS) symbology in full mission simulation
NASA Astrophysics Data System (ADS)
Sharkey, Thomas J.
1994-06-01
The U. S. Army Aeroflightdynamics Directorate's (AFDD) Crew Station Research and Development Branch (CSRDB) conducted a multiphase effort to develop symbology displaying information from the Obstacle Avoidance System (OASYS) on the Aviator's Night Vision System (ANVIS) Head Up Display (HUD). The first phase of this program used static symbology displayed on a workstation to identify the types of information required from OASYS by the pilot. The second phase used a low-fidelity, pilot-in-the-loop simulation to evaluate fourteen different symbology-drive law combinations. Based on the results of phases 1 and 2 three candidate symbologies were selected, along with the baseline symbology developed by the OASYS contractor, for evaluation in full mission simulation. In addition, a full-daylight, full field-of-view condition and Night Vision Goggle (NVG) condition, both without OASYS symbology, were used as control conditions. The environmental conditions (e.g., ambient illumination, visual range) and task requirements (e.g., altitude and airspeed) used in the simulation were selected to severely tax the symbology. Reliable differences in performance between symbology conditions were found. Two of the symbologies developed during the earlier phases of this program resulted in reduced frequencies of ground strikes compared to OASYS baseline and NVG only conditions. The frequency of close approaches to wires was lower with the symbology developed in this program than with the baseline symbology. All OASYS symbologies improved performance relative to the NVG control condition. It is recommended that the OASYS symbology and drive laws developed during this program be used during OASYS flight tests.
Bambara, Jennifer K.; Owsley, Cynthia; Wadley, Virginia; Martin, Roy; Porter, Chebon; Dreer, Laura E.
2009-01-01
Purpose To examine the prevalence of persons at risk for depression among family caregivers of visually impaired persons and the extent to which social problem-solving abilities are associated with caregiver depressive symptomatology and life satisfaction. Methods Family caregivers were defined as adults who accompanied their adult relative to an appointment at a low-vision rehabilitation clinic and self-identified themselves as the primary family caregiver responsible for providing some form of assistance for their relative due to vision impairment. Demographic variables, depressive symptoms, life satisfaction, caregiver burden, and social problem-solving abilities were assessed in caregivers. The patient’s visual acuity and depressive symptoms and their relationship to the caregiver’s depressive symptoms and life satisfaction were also examined. Results Ninety-six family caregivers were enrolled. Of those, 35.4% were identified as at risk for depression. Among caregivers, dysfunctional or ineffective social problem-solving abilities were significantly associated with greater depressive symptomatology and decreased life satisfaction after adjustment for caregiver burden and demographic and medical variables for both the caregiver and the visually impaired patient. Problem orientation or motivation to solving problems was also significantly associated with caregiver depression and satisfaction with life. Conclusions A substantial number of caregivers of visually impaired adults experience psychosocial distress, particularly among those who possess poor social problem-solving abilities. These results underscore the need for routine screening and treatment of emotional distress among individuals caring for relatives with vision impairments. Future research should examine the extent to which psychosocial interventions targeting caregiver social problem-solving skills may be useful not only in improving caregiver quality of life but also in subsequently enhancing rehabilitation outcomes for the visually impaired care recipient. PMID:19060279
Bambara, Jennifer K; Owsley, Cynthia; Wadley, Virginia; Martin, Roy; Porter, Chebon; Dreer, Laura E
2009-04-01
To examine the prevalence of persons at risk for depression among family caregivers of visually impaired persons and the extent to which social problem-solving abilities are associated with caregiver depressive symptomatology and life satisfaction. Family caregivers were defined as adults who accompanied their adult relative to an appointment at a low-vision rehabilitation clinic and self-identified themselves as the primary family caregiver responsible for providing some form of assistance for their relative due to vision impairment. Demographic variables, depressive symptoms, life satisfaction, caregiver burden, and social problem-solving abilities were assessed in caregivers. The patient's visual acuity and depressive symptoms and their relationship to the caregiver's depressive symptoms and life satisfaction were also examined. Ninety-six family caregivers were enrolled. Of those, 35.4% were identified as at risk for depression. Among caregivers, dysfunctional or ineffective social problem-solving abilities were significantly associated with greater depressive symptomatology and decreased life satisfaction after adjustment for caregiver burden and demographic and medical variables for both the caregiver and the visually impaired patient. Problem orientation or motivation to solving problems was also significantly associated with caregiver depression and satisfaction with life. A substantial number of caregivers of visually impaired adults experience psychosocial distress, particularly among those who possess poor social problem-solving abilities. These results underscore the need for routine screening and treatment of emotional distress among individuals caring for relatives with vision impairments. Future research should examine the extent to which psychosocial interventions targeting caregiver social problem-solving skills may be useful not only in improving caregiver quality of life but also in subsequently enhancing rehabilitation outcomes for the visually impaired care recipient.
Visual function and color vision in adults with Attention-Deficit/Hyperactivity Disorder.
Kim, Soyeon; Chen, Samantha; Tannock, Rosemary
2014-01-01
Color vision and self-reported visual function in everyday life in young adults with Attention-Deficit/Hyperactivity Disorder (ADHD) were investigated. Participants were 30 young adults with ADHD and 30 controls matched for age and gender. They were tested individually and completed the Visual Activities Questionnaire (VAQ), Farnsworth-Munsell 100 Hue Test (FMT) and A Quick Test of Cognitive Speed (AQT). The ADHD group reported significantly more problems in 4 of 8 areas on the VAQ: depth perception, peripheral vision, visual search and visual processing speed. Further analyses of VAQ items revealed that the ADHD group endorsed more visual problems associated with driving than controls. Color perception difficulties on the FMT were restricted to the blue spectrum in the ADHD group. FMT and AQT results revealed slower processing of visual stimuli in the ADHD group. A comprehensive investigation of mechanisms underlying visual function and color vision in adults with ADHD is warranted, along with the potential impact of these visual problems on driving performance. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
NASA Technical Reports Server (NTRS)
Cohen, Malcolm M.
1992-01-01
A review is presented of the investigations conducted into, and the recommendations made to avoid fatal A-7 Corsair II aircraft accidents during night carrier launchings in which the aircraft was apparently flown into the water. The investigating boards conjectured that the pilots were distracted from their normal cockpit procedures and that the distraction was of an insidious nature not previously experienced or expected in the night catapult/departure environment. A conference to discuss these accidents focused on aerodynamic and human factors analyses of the problem, with the goal of producing several recommendations for its resolution.
Finkelstein, Marsha; Llanos, Imelda; Scheiman, Mitchell; Wagener, Sharon Gowdy
2014-01-01
Vision impairment is common in the first year after traumatic brain injury (TBI), including among service members whose brain injuries occurred during deployment in Iraq and Afghanistan. Occupational therapy practitioners provide routine vision screening to inform treatment planning and referral to vision specialists, but existing methods are lacking because many tests were developed for children and do not screen for vision dysfunction typical of TBI. An expert panel was charged with specifying the composition of a vision screening protocol for servicemembers with TBI. A modified nominal group technique fostered discussion and objective determinations of consensus. After considering 29 vision tests, the panel recommended a nine-test vision screening that examines functional performance, self-reported problems, far–near acuity, reading, accommodation, convergence, eye alignment and binocular vision, saccades, pursuits, and visual fields. Research is needed to develop reliable, valid, and clinically feasible vision screening protocols to identify TBI-related vision disorders in adults. PMID:25005505
Dual Sensory Loss: Overview of Problems, Visual Assessment, and Rehabilitation
Brabyn, John A.; Schneck, Marilyn E.; Haegerstrom-Portnoy, Gunilla; Lott, Lori A.
2007-01-01
This article provides an overview of some of the problems and possible solutions surrounding the neglected issue of combined vision and hearing deficits. The subject is treated by considering each subpopulation, ranging from those who have no residual vision or hearing to those with mild coexisting vision and hearing losses. An attempt is made to relate the different types of visual deficit to the likely problems encountered in real-life activities, such as communication and travel, among individuals who also have a hearing impairment. The assessment and appropriate referral of patients with these combined deficits is discussed, including the interpretation of visual test results and the importance of factors other than standard visual acuity. Speculation is offered on potential strategies and solutions for rehabilitation as well as the need for future research and improvements in service delivery. PMID:18003865
... as Parkinson's disease Diseases such as arthritis or multiple sclerosis Vision or balance problems Treatment of walking problems depends on the cause. Physical therapy, surgery, or mobility aids may help.
Improving land vehicle situational awareness using a distributed aperture system
NASA Astrophysics Data System (ADS)
Fortin, Jean; Bias, Jason; Wells, Ashley; Riddle, Larry; van der Wal, Gooitzen; Piacentino, Mike; Mandelbaum, Robert
2005-05-01
U.S. Army Research, Development, and Engineering Command (RDECOM) Communications Electronics Research, Development and Engineering Center (CERDEC) Night Vision and Electronic Sensors Directorate (NVESD) has performed early work to develop a Distributed Aperture System (DAS). The DAS aims at improving the situational awareness of armored fighting vehicle crews under closed-hatch conditions. The concept is based on a plurality of sensors configured to create a day and night dome of surveillance coupled with heads up displays slaved to the operator's head to give a "glass turret" feel. State-of-the-art image processing is used to produce multiple seamless hemispherical views simultaneously available to the vehicle commander, crew members and dismounting infantry. On-the-move automatic cueing of multiple moving/pop-up low silhouette threats is also done with the possibility to save/revisit/share past events. As a first step in this development program, a contract was awarded to United Defense to further develop the Eagle VisionTM system. The second-generation prototype features two camera heads, each comprising four high-resolution (2048x1536) color sensors, and each covering a field of view of 270°hx150°v. High-bandwidth digital links interface the camera heads with a field programmable gate array (FPGA) based custom processor developed by Sarnoff Corporation. The processor computes the hemispherical stitch and warp functions required for real-time, low latency, immersive viewing (360°hx120°v, 30° down) and generates up to six simultaneous extended graphics array (XGA) video outputs for independent display either on a helmet-mounted display (with associated head tracking device) or a flat panel display (and joystick). The prototype is currently in its last stage of development and will be integrated on a vehicle for user evaluation and testing. Near-term improvements include the replacement of the color camera heads with a pixel-level fused combination of uncooled long wave infrared (LWIR) and low light level intensified imagery. It is believed that the DAS will significantly increase situational awareness by providing the users with a day and night, wide area coverage, immersive visualization capability.
NASA Astrophysics Data System (ADS)
Pasko, V. P.; Stanley, M.; Mathews, J. D.; Inan, U. S.; Wood, T. G.; Cummer, S. A.; Williams, E. R.; Heavner, M. J.
2002-12-01
In August-September 2001 an experimental campaign has been conducted in Puerto Rico to perform correlative studies of lightning and lightning-induced ionospheric effects. The campaign, which was sponsored by a Small Grant for Exploratory Research from the National Science Foundation to Penn State University, had a broad range of scientific goals including studies ionospheric effects of thunderstorms, studies of VHF-quiet positive leaders and studies of large scale optical phenomena above ocean thunderstorms in tropics. As part of this program we conducted night time video recordings of lightning and large scale luminous phenomena above thunderstorms using a SONY DCR TRV 730 CCD video camera equipped with a blue extended ITT Night Vision GEN III NQ 6010 intensifier with 40 deg field of view. The intensifier provided a monochrome (predominantly green) image output. The video system was deployed at the Lidar Laboratory on the grounds of Arecibo Observatory, Puerto Rico (18.247 deg N, 66.754 deg W, elevation 305 m above the sea level). In this talk we report results of observations conducted between 01 and 03 UT on September 3, 2001. A total of 7 sprite events have been detected above a large thunderstorm system (cloud area exceeding 104 km2) located approximately 500 km from the observational site above Haiti/Dominican Republic. The observed events exhibited typical sprite features documented in other parts of the globe, including single columns, groups of columns, relatively small horizontal glows confined to higher altitudes, as well as two large and impulsive events with the transverse extent ~eq50 km. In this talk we will also report results of preliminary analysis of available ELF electromagnetic signatures associated with the observed events recorded by Stanford University at Palmer Station, Antarctica, Duke University, MIT and Los Alamos Sferic Array in Florida. Acknowledgments: The GEN III intensifier has been provided by ITT Night Vision Industries. We are grateful to M. Robinson of ITT Industries for support of our program. We thank W. Lyons for useful discussions. We are indebted to S. Gonzalez, Q. Zhou, M. Sulzer, C. Tepley, J. Friedman, E. Robles, A. Venkataraman and E. Castro for support of our observations at Arecibo Observatory.
Computer vision for microscopy diagnosis of malaria.
Tek, F Boray; Dempster, Andrew G; Kale, Izzet
2009-07-13
This paper reviews computer vision and image analysis studies aiming at automated diagnosis or screening of malaria infection in microscope images of thin blood film smears. Existing works interpret the diagnosis problem differently or propose partial solutions to the problem. A critique of these works is furnished. In addition, a general pattern recognition framework to perform diagnosis, which includes image acquisition, pre-processing, segmentation, and pattern classification components, is described. The open problems are addressed and a perspective of the future work for realization of automated microscopy diagnosis of malaria is provided.
To See Anew: New Technologies Are Moving Rapidly Toward Restoring or Enabling Vision in the Blind.
Grifantini, Kristina
2017-01-01
Humans have been using technology to improve their vision for many decades. Eyeglasses, contact lenses, and, more recently, laser-based surgeries are commonly employed to remedy vision problems, both minor and major. But options are far fewer for those who have not seen since birth or who have reached stages of blindness in later life.
"Better" People, Better Teaching: The Vision of the National Teacher Corps, 1965-1968
ERIC Educational Resources Information Center
Rogers, Bethany
2009-01-01
This article focuses on the period between 1966 and 1968, when the original vision of the policymakers of the National Teacher Corps (NTC) and the federal staffers who created the NTC initiative held sway. In their vision, the "best and brightest" (according to their criteria) could better solve the problems of educating so-called disadvantaged…
Temporal Properties of Liquid Crystal Displays: Implications for Vision Science Experiments
Elze, Tobias; Tanner, Thomas G.
2012-01-01
Liquid crystal displays (LCD) are currently replacing the previously dominant cathode ray tubes (CRT) in most vision science applications. While the properties of the CRT technology are widely known among vision scientists, the photometric and temporal properties of LCDs are unfamiliar to many practitioners. We provide the essential theory, present measurements to assess the temporal properties of different LCD panel types, and identify the main determinants of the photometric output. Our measurements demonstrate that the specifications of the manufacturers are insufficient for proper display selection and control for most purposes. Furthermore, we show how several novel display technologies developed to improve fast transitions or the appearance of moving objects may be accompanied by side–effects in some areas of vision research. Finally, we unveil a number of surprising technical deficiencies. The use of LCDs may cause problems in several areas in vision science. Aside from the well–known issue of motion blur, the main problems are the lack of reliable and precise onsets and offsets of displayed stimuli, several undesirable and uncontrolled components of the photometric output, and input lags which make LCDs problematic for real–time applications. As a result, LCDs require extensive individual measurements prior to applications in vision science. PMID:22984458
NASA Astrophysics Data System (ADS)
Valberg, Arne
2005-04-01
Light Vision Color takes a well-balanced, interdisciplinary approach to our most important sensory system. The book successfully combines basics in vision sciences with recent developments from different areas such as neuroscience, biophysics, sensory psychology and philosophy. Originally published in 1998 this edition has been extensively revised and updated to include new chapters on clinical problems and eye diseases, low vision rehabilitation and the basic molecular biology and genetics of colour vision. Takes a broad interdisciplinary approach combining basics in vision sciences with the most recent developments in the area Includes an extensive list of technical terms and explanations to encourage student understanding Successfully brings together the most important areas of the subject in to one volume
The global problem of blindness and visual dysfunction
NASA Astrophysics Data System (ADS)
Lakshminarayanan, Vasudevan
2012-10-01
According to World Health Organization statistics there are approximately 285 million people who are blind, have severe low vision, or are near-blind. Of these, 39 million are blind, and 246 million have low vision problems. About 90% of these live in developing countries. The major causes are uncorrected refractive errors (42%), and cataracts (38%). In the US, there are about 6 million people over the age of 65 who have age-related macular degeneration which is the leading cause of blindness. For each decade after age 40, it is found that there is a three-fold increase in the prevalence of blindness and low vision. This paper will address the question of what can we, as optical physicists and engineers, do? There is a need for efficient methods to detect problems, investigate function, provide solutions, and develop rehabilitation devices for the visually impaired. Here I will sketch out the magnitude and variety of the problem, examples and future research directions.
Nocturnality constrains morphological and functional diversity in the eyes of reef fishes.
Schmitz, Lars; Wainwright, Peter C
2011-11-19
Ambient light levels are often considered to drive the evolution of eye form and function. Diel activity pattern is the main mechanism controlling the visual environment of teleost reef fish, with day-active (diurnal) fish active in well-illuminated conditions, whereas night-active (nocturnal) fish cope with dim light. Physiological optics predicts several specific evolutionary responses to dim-light vision that should be reflected in visual performance features of the eye. We analyzed a large comparative dataset on morphological traits of the eyes in 265 species of teleost reef fish in 43 different families. The eye morphology of nocturnal reef teleosts is characterized by a syndrome that indicates better light sensitivity, including large relative eye size, high optical ratio and large, rounded pupils. Improved dim-light image formation comes at the cost of reduced depth of focus and reduction of potential accommodative lens movement. Diurnal teleost reef fish, released from the stringent functional requirements of dim-light vision have much higher morphological and optical diversity than nocturnal species, with large ranges of optical ratio, depth of focus, and lens accommodation. Physical characteristics of the environment are an important factor in the evolution and diversification of the vertebrate eye. Both teleost reef fish and terrestrial amniotes meet the functional requirements of dim-light vision with a similar evolutionary response of morphological and optical modifications. The trade-off between improved dim-light vision and reduced optical diversity may be a key factor in explaining the lower trophic diversity of nocturnal reef teleosts.
Vision rehabilitation for visual-vestibular dysfunction: the role of the neuro-optometrist.
Cohen, Allen H
2013-01-01
This article discusses, in a clinically relevant format, the importance of including a neuro-optometrist as a member of the management team for patients with balance disorders. To review the importance of vision and visual processing for maintaining a sense of balance and equilibrium and the role of the neuro-optometrist in the overall rehabilitation of patients with balance disorders Dizziness, balance problems and the sensation that the space world is moving (vertigo) are one of the most commonly reported problems in general medical practice. Persons with a central nervous system injury or other idiopathic causes of visual processing problems or who have functional vision problems that are not adequately managed, often experience extreme difficulty with balance and movement, as well as with their perception of space. Consequently, the patient often experiences difficulty functioning in an environment with excessive visual stimulation such as a grocery store or shopping mall. Symptoms of disequilibrium, vestibular and balance problems are commonly a result of VOR disturbance secondary to an inner ear problem and an unstable binocularity. The combination of neuro-optomertic rehabilitative therapy and balance therapy will result in a is an effective treatment for reducing or resolving these symptoms.
[The effect of drugs used in treatment of skin disorders on visual system].
Szostakiewicz-Grabek, Beata; Juszkiewicz-Borowiec, Maria; Krasowska, Dorota
2016-04-01
Drugs with side effects affecting vision are often used in the treatment of skin disorders. The study evaluated principal groups of medicines which may negatively influence vision and the eye itself. Antimalaric drugs may cause a number of disorders of vision and a diagnosed retinophaty is an absolute contraindication. Retinoids often cause a dry eye condition, which results in intolerance to wearing contact lenses. They can also be a cause of poor nightly vision. Psoralens, used in photochemotherapy, can penetrate to the frontal part of the eye, inducing clouding of the lens and cataract. Glucocorticosteroids, often used in skin conditions, increase intraocular pressure, which may result in development of glaucoma. Methotrexate may also cause complications, such as eyelid edema, conjunctival hyperemia, increased lacrimation and photophobia. A prolonged use of tetracyclines may induce side effect in eye organs. Swelling of the optic nerve head with subsequent decreased vision, and even accumulate of metabolites of tetracycline within the conjunctival were observed. In the study a distinction was made between the medications which may lead to a temporary visual impairment and the medication with a side effect lasting beyond the treatment. It was pointed out that some of the side effects could be avoided or minimised by not combining retinoids and tetracyclines or with the use of protective eyewear during photochemotherapy. An examination by ophthalmologist is a crucial step prior to the treatment with chloroquine, hydroxychloroquine or psoralens. Regular eye exams are necessary when using, especially in a protracted fashion, most of the discussed drugs. Finally, the cooperation between dermatologist and ophthalmologist is fundamental for ensuring patient's safety. © 2016 MEDPRESS.
Mundy, N I; Morningstar, N C; Baden, A L; Fernandez-Duque, E; Dávalos, V M; Bradley, B J
2016-01-01
Do evolutionary specializations lead to evolutionary constraint? This appears plausible, particularly when specialization leads to loss of complex adaptations. In the owl monkey lineage, nocturnality clearly arose from a diurnal ancestor. This behavioural shift was accompanied by morphological changes in the eye and orbit and complete loss of colour vision via missense mutations in the gene encoding the short-wave sensitive visual pigment (SWS opsin). Interestingly, at least one subspecies of owl monkey, Azara's owl monkey (Aotus azarae azarae), has regained activity in daylight. Given that all primate species that are active in daylight, including primarily diurnal species and species that are active during both day and night, have at least dichromatic colour vision, it seems reasonable to propose that dichromacy would be adaptive in A. a. azarae. With a disabled SWS opsin, the main avenue available for Azara's owl monkeys to re-evolve colour vision is via a polymorphism in the intact X-linked opsin locus, which commonly occurs in other New World monkeys. To examine this possibility we assayed variation in the X-linked opsin of A. a. azarae, focusing on the three exons (3, 4 and 5) that control spectral sensitivity. We found low opsin genetic variation on a population level, and no differences at the three main sites that lead to variation in spectral sensitivity in the opsins of other New World monkeys. Two rare alleles with single amino acid variants are segregating in the population, but previous functional studies indicate that these are unlikely to affect spectral sensitivity. Genetic constraint on the re-evolution of colour vision is likely operating in Azara's owl monkey, which may affect the niche that this subspecies is able to occupy.
... by slowing activity in the brain to allow sleep. ... nights after you stop taking the medication.Your sleep problems should improve within 7 to 10 days ... start taking flurazepam. Call your doctor if your sleep problems do not improve during this time, if ...
... by slowing activity in the brain to allow sleep. ... full night after you take the medication.Your sleep problems should improve within 7 to 10 days ... start taking estazolam. Call your doctor if your sleep problems do not improve during this time, if ...
ERIC Educational Resources Information Center
Cannon, Lawrence O.; Elich, Joe
In most mathematics problem solving work, students' motivation comes from trying to please their teachers or to earn a good grade. The questions students must tackle are almost never generated by their own interest. Seven open-ended college algebra-level problems are presented in which the solution of one question suggests other related questions.…
The effect of day and night shifts on oxidative stress and anxiety symptoms of the nurses.
Ulas, T; Buyukhatipoglu, H; Kirhan, I; Dal, M S; Eren, M A; Hazar, A; Demir, M E; Aydogan, T; Karababa, F; Uyanikoglu, A; Kurkcuoglu, I C
2012-05-01
Oxidative stress is believed to have a role in the development of chronic diseases. It is also known that long-term night and shift work in nurses might be associated with many health-related problems like fatigue, sleep problems, anxiety and difficulties in maintaining regular lifestyles. In this study, we aimed to evaluate the changes of oxidative stress parameters and anxiety indexes of the nurses on day and night shifts. One hundred and twenty nurses in ordinary service and intensive care unit (ICU) were enrolled to the study. Subjects were divided into 2 groups; group 1 (n = 60) consisted of nurses working in a day shift and group 2 (n = 60) as working in the night shift. Further, both groups were divided in to 2 groups again; group la and 2a (both n = 30) who working in the ICU, group 1b and 2b (both n = 30) in the ordinary service. Just before and the end of the shifts, blood samples were obtained to measure total antioxidant status (TAS) and total oxidant status (TOS). Oxidative stress index (OSI) was calculated. Anxiety index were determined at the end of the shift using State-Trait Anxiety Inventory index. Oxidative stress parameters were increased in all nurses at the end of the day and night shifts (p < 0.05). However, both in service and ICU nurses TAS, TOS, and OSI levels were not significantly different at the beginning and the end of the shifts (p > 0.05). Anxiety indexes of each ordinary service and ICU nurses were found to be similar (p > 0.05). Ordinary service and ICU nurses' oxidative stress parameters and anxiety indexes were not different and all nurses suffer the similar effects of the shifts both in day and night.
Vision impairment and nutritional status among older assisted living residents.
Muurinen, Seija M; Soini, Helena H; Suominen, Merja H; Saarela, Riitta K T; Savikko, Niina M; Pitkälä, Kaisu H
2014-01-01
Vision impairment is common among older persons. It is a risk factor for disability, and it may be associated with nutritional status via decline in functional status. However, only few studies have examined the relationship between vision impairment and nutritional status, which was investigated in this cross-sectional study. The study included all residents living in the assisted living facilities in Helsinki and Espoo in 2007. Residents in temporary respite care were excluded (5%). Of permanent residents (N=2214), 70% (N=1475) consented. Trained nurses performed a personal interview and assessment of each resident including the Mini Nutritional Assessment (MNA), functional and health status. Patient records were used to confirm demographic data and medical history. Mortality in 2010 was retrieved from central registers. Of the residents, 17.5% (N=245) had vision impairment and they were not able to read regular print. Those with vision impairment were older, more often females, and malnourished according to MNA. They had lower BMI, and suffered more often from dementia and chewing problems than those without vision impairment. In logistic regression analysis controlling for age, gender, chewing problems and dementia, vision impairment was independently associated with resident's malnutrition (OR 2.51, 95% CI 1.80-3.51). According to our results older residents in assisted living with vision impairment are at high risk for malnutrition. Therefore it is important to assess nutritional status of persons with vision impairment. It would be beneficial to repeat this kind of a study also in elderly community population. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
High Dynamic Range Digital Imaging of Spacecraft
NASA Technical Reports Server (NTRS)
Karr, Brian A.; Chalmers, Alan; Debattista, Kurt
2014-01-01
The ability to capture engineering imagery with a wide degree of dynamic range during rocket launches is critical for post launch processing and analysis [USC03, NNC86]. Rocket launches often present an extreme range of lightness, particularly during night launches. Night launches present a two-fold problem: capturing detail of the vehicle and scene that is masked by darkness, while also capturing detail in the engine plume.
ERIC Educational Resources Information Center
Karter, M. Joshua
1994-01-01
Discusses some of the problems the author encountered in staging a production of Marsha Norman's "'night, Mother" in Moscow. States that the area of largest concern was cultural variables, and whether a Russian audience would be able to understand some of the references. Concludes that, despite cultural differences, the audience was…
Gary L. Achtemeier
1999-01-01
The use of fire for controlled burning to meet objectives for silviculture or for ecosystem management carries the risk of liability for smoke. Near-ground smoke can degrade air quality, reduce visibility, aggravate health problems, and create a general nuisance. At night, smoke can locally limit visibility over roadways creating serious hazards to transportation. PB-...
Psychology and Optometry: Interaction and Collaboration.
ERIC Educational Resources Information Center
Biaggio, Mary Kay; Bittner, Erika
1990-01-01
Because a number of vision conditions have psychological components and some psychological conditions may be complicated by vision difficulties, interdisciplinary cooperation between clinical psychology and optometry should prove fruitful for the diagnosis, treatment, and management of health problems. (EVL)
The handicap of abnormal colour vision.
Cole, Barry L
2004-07-01
All people with abnormal colour vision, except for a few mildly affected deuteranomals, report that they experience problems with colour in everyday life and at work. Contemporary society presents them with increasing problems because colour is now so widely used in printed materials and in computer displays. Equal opportunity law gives them protection against unfair discrimination in employment, so a decision to exclude a person from employment on the grounds of abnormal colour vision must now be well supported by good evidence and sound argument. This paper reviews the investigations that have contributed to understanding the nature and consequences of the problems they have. All those with abnormal colour vision are at a disadvantage with comparative colour tasks that involve precise matching of colours or discrimination of fine colour differences either because of their loss of colour discrimination or anomalous perception of metamers. The majority have problems when colour is used to code information, in man-made colour codes and in naturally occurring colour codes that signal ripeness of fruit, freshness of meat or illness. They can be denied the benefit of colour to mark out objects and organise complex visual displays. They may be unreliable when a colour name is used as an identifier. They are slower and less successful in search when colour is an attribute of the target object or is used to organise the visual display. Because those with the more severe forms of abnormal colour vision perceive a very limited gamut of colours, they are at a disadvantage in the pursuit and appreciation of those forms of art that use colour.
Sorting of colors in the retina
NASA Astrophysics Data System (ADS)
Ribak, Erez; Labin, Amichai; Safuri, Shadi; Perlman, Ido
2015-03-01
Our image of the world is detected by photoreceptors, lying at the bottom of the nearly-transparent retina. Lateral neural layers for processing the image temporally, spectrally, and spatially come in front the photoreceptors, not behind them. This reverse order is a long-standing puzzle, which we wish to explain. We found out that cone photoreceptors are attached to metabolic Muller cells which span the retina. Cones provide colour vision at day time, and are surrounded by sensitive rods which function at night. We showed by an analytical and a computational method that the Müller cells also serve as fibre optics, concentrating green-red light into the cones, while the excessive blue is scattered to the nearby rods. Spatial and spectral laboratory measurements validate that indeed the shapes and refractive index values of the Muller cells and the surrounding retina separate the colours according to the spectral sensitivities of both cones and rods. These results also explain other effects of vision acuity and colour sensitivity.
Hanaya, Junko; Nakamura, Yasuko; Nejima, Ryouhei; Miyata, Kazunori; Mera, Kentarou; Ohguro, Hiroshi; Yamamoto, Shuichi
2011-06-01
We report a case of melanoma-associated retinopathy (MAR) associated with positive auto-antibodies against retinal bipolar cells, which has been rarely reported in Japan. A 33 year-old woman noticed shimmering vision, photopsias, blurred vision, and night blindness OS in April 2009, and visited Kagoshima Miyata Eye Clinic in May 2009. She had been continuously treated for malignant melanoma on her left finger since 2007. At her initial visit, the corrected visual acuity was 1.5 OD and 1.2 OS, and slit-lamp examination revealed clear ocular media OU. Funduscopic examination showed normal appearance of the retina OU, except for a mild narrowing of the retinal arteries OS. Humphrey field analyzer revealed a reduction of retinal sensitivity within the central 30 degrees OS. The maximum left eye response of electroretinogram (ERG) showed a negative waveform. The immuno-cytochemical test revealed antibodies against retinal bipolar cells, which confirmed the diagnosis of MAR. Characteristic subjective symptoms, Humphrey field analyzer and ERG are useful for the diagnosis of MAR.
Advances in repairing the degenerate retina by rod photoreceptor transplantation☆
Pearson, Rachael A.
2014-01-01
Despite very different aetiologies, age-related macular degeneration (AMD) and most inherited retinal disorders culminate in the same final common pathway, loss of the light-sensitive photoreceptors. There are few clinical treatments and none can reverse the loss of vision. Photoreceptor replacement by transplantation is proposed as a broad treatment strategy applicable to all degenerations. The past decade has seen a number of landmark achievements in this field, which together provide strong justification for continuing investigation into photoreceptor replacement strategies. These include proof of principle for restoring vision by rod-photoreceptor transplantation in mice with congenital stationary night blindness and advances in stem cell biology, which have led to the generation of complete optic structures in vitro from embryonic stem cells. The latter represents enormous potential for generating suitable and renewable donor cells with which to achieve the former. However, there are still challenges presented by the degenerating recipient retinal environment that must be addressed as we move to translating these technologies towards clinical application. PMID:24412415
NASA Technical Reports Server (NTRS)
1989-01-01
Biomedical Optical Company of America's (BOCA) suntiger lenses, similar in principle to natural filters in the eyes of hawks and eagles, bar 99 percent of potentially harmful wavelengths, while allowing visually useful colors of light (red, orange, green) to pass through. They also improve visual acuity, night vision and haze or fog visibility. The lenses evolved from work done by James B. Stephens and Dr. Charles G. Miller of the Jet Propulsion Laboratory. They developed a formula and produced a commercial welding curtain that absorbs, filters, and scatters light. This research led to protective glasses now used by dentists, workers in hazardous environments, CRT operators and skiers.
Combatant eye protection: an introduction to the blue light hazard
NASA Astrophysics Data System (ADS)
Lattimore, Morris R.
2016-05-01
Emerging evidence of metabolic vulnerability to visible blue light is vitally important, as it is indicative of a scalable threshold effect. Added stressors (e.g., increased altitude or contact lens wear) could shift the wavelength effects toward a more damaging clinical picture. Recent reports have indicated rod photo-pigment damage resulting from solar blue-light exposures, adversely affecting unaided night vision, a militarily important performance decrement. The activation wavelength for the daily synchronous setting of the Circadian Clock, which regulates the synchronization of all hormonal and organ systems throughout the body, falls within this blue light perceptual range.
Two-Photon Absorption Characterization of HgCdTe
1990-07-30
r17 L3 _ , 952L2 9521- 240 L 976 , 210 979 LU ’~-~’ ~180~ - Eg=136.0 _-0.5 m eV Z-150 T 7K W FIG. 2. Wavelength depend- 0120[0 0 12 > ence of the...8217 / Army Center for Night Vision and Electro-Optics, Contract 0 i No. DAAB07-87-C-FO94. j W 9.329 FIG. 12. Wavelength depend- w ence of the...pres- presented in Fig. I. The two-photon magnetoabsorption ence of impurities and defects in samples of MCT with (TPMA) transitions are indicated by
NASA Technical Reports Server (NTRS)
Hansen, R. G.; Byrd, E. A.
1983-01-01
The primary development of cryogenically cooled infrared systems was accomplished by FLIR systems designed for airborne, passive night vision. Essential to the development of these FLIR systems was a family of closed cycle refrigerators which had to meet a limited envelope requirement, utilize a nonlubricated compressor module, and be light in weight. Closed cycle refrigerators accomplished the same cooling function, they use modified oil lubricated reciprocating compressors which are limited in their axis of orientation to an angle of approximately 15-20 degrees maximum from horizon.
Retinitis pigmentosa and congenital toxoplasmosis: a rare coexistence.
Chhabra, Manpreet S; Prakash, Gunjan; Vashisht, Nagender; Garg, S P
2007-01-01
We describe a previously unreported co-existence of retinitis pigmentosa and congenital toxoplasmosis. An eight year old male presented to our center with complaints of decreased night vision. Fundus evaluations in both the eyes demonstrated features typical of retinitis pigmentosa. There were well-defined punched out healed chorio-retinal scars suggestive of congenital toxoplasmosis. On the basis of history, clinical findings and reduction of a and b wave amplitudes on scotopic and photopic electroretinograph, a diagnosis of retinitis pigmentosa with congenital toxoplasmosis was made. Retinitis pigmentosa may co-exist with congenital toxoplasmosis that may affect the patient's overall ocular morbidity and visual acuity.
Scotopic vision deficits in young monkeys exposed to lead.
Bushnell, P J; Bowman, R E; Allen, J R; Marlar, R J
1977-04-15
Rhesus monkeys were reared on diets designed to produce blood lead concentrations of 14 (untreated), 55, or 85 micrograms per 100 milliliters for the first year of life. Eighteen months later, blood lead levels were normal in all animals. At this time, however, visual discrimination performance in the 85-microgram group was impaired under dim light relative both to their own performance under bright light and to the performance of the other groups under all light levels used. We interpret these results to reflect a deleterious, enduring impairment of scotopic visual function (night blindness) as a result of early lead intoxication.
Advanced helmet tracking technology developments for naval aviation
NASA Astrophysics Data System (ADS)
Brindle, James H.
1996-06-01
There is a critical need across the Services to improve the effectiveness of aircrew within the crewstation by capitalizing on the natural psycho-motor skills of the pilot through the use of a variety of helmet-mounted visual display and control techniques. This has resulted in considerable interest and significant ongoing research and development efforts on the part of the Navy, as well as the Army and the Air Force, in the technology building blocks associated with this area, such as advanced head position sensing or head tracking technologies, helmet- mounted display optics and electronics, and advanced night vision or image intensification technologies.
A Projection free method for Generalized Eigenvalue Problem with a nonsmooth Regularizer.
Hwang, Seong Jae; Collins, Maxwell D; Ravi, Sathya N; Ithapu, Vamsi K; Adluru, Nagesh; Johnson, Sterling C; Singh, Vikas
2015-12-01
Eigenvalue problems are ubiquitous in computer vision, covering a very broad spectrum of applications ranging from estimation problems in multi-view geometry to image segmentation. Few other linear algebra problems have a more mature set of numerical routines available and many computer vision libraries leverage such tools extensively. However, the ability to call the underlying solver only as a "black box" can often become restrictive. Many 'human in the loop' settings in vision frequently exploit supervision from an expert, to the extent that the user can be considered a subroutine in the overall system. In other cases, there is additional domain knowledge, side or even partial information that one may want to incorporate within the formulation. In general, regularizing a (generalized) eigenvalue problem with such side information remains difficult. Motivated by these needs, this paper presents an optimization scheme to solve generalized eigenvalue problems (GEP) involving a (nonsmooth) regularizer. We start from an alternative formulation of GEP where the feasibility set of the model involves the Stiefel manifold. The core of this paper presents an end to end stochastic optimization scheme for the resultant problem. We show how this general algorithm enables improved statistical analysis of brain imaging data where the regularizer is derived from other 'views' of the disease pathology, involving clinical measurements and other image-derived representations.
Wright, Cameron H G; Barrett, Steven F; Pack, Daniel J
2005-01-01
We describe a new approach to attacking the problem of robust computer vision for mobile robots. The overall strategy is to mimic the biological evolution of animal vision systems. Our basic imaging sensor is based upon the eye of the common house fly, Musca domestica. The computational algorithms are a mix of traditional image processing, subspace techniques, and multilayer neural networks.
Kernelized Locality-Sensitive Hashing for Fast Image Landmark Association
2011-03-24
based Simultaneous Localization and Mapping ( SLAM ). The problem, however, is that vision-based navigation techniques can re- quire excessive amounts of...up and optimizing the data association process in vision-based SLAM . Specifically, this work studies the current methods that algorithms use to...required for location identification than that of other methods. This work can then be extended into a vision- SLAM implementation to subsequently
Bover, M T; Foulds, J; Steinberg, M B; Richardson, D; Marcella, S W
2008-02-01
This study aimed to describe the characteristics of treatment-seeking patients who wake at night to smoke (night-smoking), identify factors that may be associated with night-smoking, and assess the association between night-smoking and treatment outcome. A total of 2312 consecutive eligible cigarette smokers who sought treatment at a specialist tobacco-dependence clinic declared a Target Quit Date, provided baseline information at assessment, and were then followed-up 4 and 26 weeks after their target quit date. Of the total sample, 51.1% were identified as night-smokers and 25.1% reported smoking abstinence at 26-week follow-up. Night-smoking was associated with a number of other patient characteristics, including African-American race or Hispanic ethnicity, having smoking-related medical symptoms, having been treated for a behavioural health problem, smoking mentholated cigarettes, smoking within 30 min of waking in the morning, increased cigarettes smoked per day, and not having private health insurance. In multivariate analyses, night-smoking at assessment remained a significant predictor of smoking at 26-week follow-up when controlling for other factors associated with treatment outcome (adjusted odds ratio: 0.77, 95% confidence interval: 0.62-0.96). Night-smokers also experienced a shorter average time to relapse (38.5 vs. 56 days, p<0.0001). Several socioeconomic and tobacco use characteristics are shared among patients who wake at night to smoke. This behaviour can be assessed by a simple question and used as a marker for tobacco dependence and as an indicator that more intensive and sustained treatment may be required.
A 3D terrain reconstruction method of stereo vision based quadruped robot navigation system
NASA Astrophysics Data System (ADS)
Ge, Zhuo; Zhu, Ying; Liang, Guanhao
2017-01-01
To provide 3D environment information for the quadruped robot autonomous navigation system during walking through rough terrain, based on the stereo vision, a novel 3D terrain reconstruction method is presented. In order to solve the problem that images collected by stereo sensors have large regions with similar grayscale and the problem that image matching is poor at real-time performance, watershed algorithm and fuzzy c-means clustering algorithm are combined for contour extraction. Aiming at the problem of error matching, duel constraint with region matching and pixel matching is established for matching optimization. Using the stereo matching edge pixel pairs, the 3D coordinate algorithm is estimated according to the binocular stereo vision imaging model. Experimental results show that the proposed method can yield high stereo matching ratio and reconstruct 3D scene quickly and efficiently.
Bakaraju, Ravi C; Tilia, Daniel; Sha, Jennifer; Diec, Jennie; Chung, Jiyoon; Kho, Danny; Delaney, Shona; Munro, Anna; Thomas, Varghese
To compare the visual performance of prototype contact lenses designed via deliberate manipulation of higher-order spherical aberrations to extend-depth-of-focus with two commercial multifocals, after 1 week of lens wear. In a prospective, participant-masked, cross-over, randomized, 1-week dispensing clinical-trial, 43 presbyopes [age: 42-63 years] each wore AIROPTIX Aqua multifocal (AOMF), ACUVUE OASYS for presbyopia (AOP) and extended-depth-of-focus prototypes (EDOF) appropriate to their add requirements. Measurements comprised high-contrast-visual-acuity (HCVA) at 6m, 70cm, 50cm and 40cm; low-contrast-visual-acuity (LCVA) and contrast-sensitivity (CS) at 6m and stereopsis at 40cm. A self-administered questionnaire on a numeric-rating-scale (1-10) assessed subjective visual performance comprising clarity-of-vision and lack-of-ghosting at various distances during day/night-viewing conditions and overall-vision-satisfaction. EDOF was significantly better than AOMF and AOP for HCVA averaged across distances (p≤0.038); significantly worse than AOMF for LCVA (p=0.021) and significantly worse than AOMF for CS in medium and high add-groups (p=0.006). None of these differences were clinically significant (≤2 letters). EDOF was significantly better than AOMF and AOP for mean stereoacuity (36 and 13 seconds-of-arc, respectively: p≤0.05). For clarity-of-vision, EDOF was significantly better than AOP at all distances and AOMF at intermediate and near (p≤0.028). For lack-of-ghosting averaged across distances, EDOF was significantly better than AOP (p<0.001) but not AOMF (p=0.186). EDOF was significantly better than AOMF and AOP for overall-vision-satisfaction (p≤0.024). EDOF provides better intermediate and near vision performance than either AOMF or AOP with no difference for distance vision after 1 week of lens wear. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Buckingham, Bruce A; Cameron, Fraser; Calhoun, Peter; Maahs, David M; Wilson, Darrell M; Chase, H Peter; Bequette, B Wayne; Lum, John; Sibayan, Judy; Beck, Roy W; Kollman, Craig
2013-08-01
Nocturnal hypoglycemia is a common problem with type 1 diabetes. In the home setting, we conducted a pilot study to evaluate the safety of a system consisting of an insulin pump and continuous glucose monitor communicating wirelessly with a bedside computer running an algorithm that temporarily suspends insulin delivery when hypoglycemia is predicted. After the run-in phase, a 21-night randomized trial was conducted in which each night was randomly assigned 2:1 to have either the predictive low-glucose suspend (PLGS) system active (intervention night) or inactive (control night). Three predictive algorithm versions were studied sequentially during the study for a total of 252 intervention and 123 control nights. The trial included 19 participants 18-56 years old with type 1 diabetes (hemoglobin A1c level of 6.0-7.7%) who were current users of the MiniMed Paradigm® REAL-Time Revel™ System and Sof-sensor® glucose sensor (Medtronic Diabetes, Northridge, CA). With the final algorithm, pump suspension occurred on 53% of 77 intervention nights. Mean morning glucose level was 144±48 mg/dL on the 77 intervention nights versus 133±57 mg/dL on the 37 control nights, with morning blood ketones >0.6 mmol/L following one intervention night. Overnight hypoglycemia was lower on intervention than control nights, with at least one value ≤70 mg/dL occurring on 16% versus 30% of nights, respectively, with the final algorithm. This study demonstrated that the PLGS system in the home setting is safe and feasible. The preliminary efficacy data appear promising with the final algorithm reducing nocturnal hypoglycemia by almost 50%.
Folkard, Simon
2008-04-01
"Permanent" or "fixed" night shifts have been argued to offer a potential benefit over rotating shift systems in that they may serve to maximize circadian adjustment and hence minimize the various health and safety problems associated with night work. For this reason, some authors have argued in favor of permanent shift systems, but their arguments assume at least a substantial, if not complete, adjustment of the circadian clock. They have emphasized the finding that the day sleeps taken between successive night shifts by permanent night workers are rather longer than those of either slowly or rapidly rotating shift workers, but this could simply reflect increased pressure for sleep. The present paper reviews the literature on the adjustment to permanent night work of the circadian rhythm in the secretion of melatonin, which is generally considered to be the best known indicator of the state of the endogenous circadian body clock. Studies of workers in "abnormal" environments, such as oil rigs and remote mining operations, were excluded, as the nature of these unique settings might serve to assist adjustment. The results of the six studies included indicate that only a very small minority (<3%) of permanent night workers evidence "complete"adjustment of their endogenous melatonin rhythm to night work, less than one in four permanent night workers evidence sufficiently "substantial" adjustment to derive any benefit from it, there is no difference between studies conducted in normal or dim lighting, and there is no evidence of gender difference in the adjustment to permanent night work. It is concluded that in normal environments, permanent night-shift systems are unlikely to result in sufficient circadian adjustment in most individuals to benefit health and safety.
Neuropsychological functioning related to specific characteristics of nocturnal enuresis.
Van Herzeele, C; Dhondt, K; Roels, S P; Raes, A; Groen, L-A; Hoebeke, P; Walle, J Vande
2015-08-01
There is a high comorbidity demonstrated in the literature between nocturnal enuresis and several neuropsychological dysfunctions, with special emphasis on attention deficit hyperactivity disorder (ADHD). However, the majority of the psychological studies did not include full non-invasive screening and failed to differentiate between monosymptomatic nocturnal enuresis (MNE) and non-MNE patients. The present study primarily aimed to investigate the association between nocturnal enuresis and (neuro)psychological functioning in a selective homogeneous patient group, namely: children with MNE and associated nocturnal polyuria (NP). Secondly, the study investigated the association between specific characteristics of nocturnal enuresis (maximum voided volume, number of wet nights and number of nights with NP) and ADHD-inattentive symptoms, executive functioning and quality of life. The psychological measurements were multi-informant (parents, children and teachers) and multi-method (questionnaires, clinical interviews and neuropsychological testing). Thirty children aged 6-16 years (mean 10.43 years, SD 3.08) were included. Of them, 80% had at least one psychological, motor or neurological difficulty. The comorbid diagnosis of ADHD, especially the predominantly inattentive presentation, was most common. According to the teachers, a low maximum voided volume (corrected for age) was associated with more attention problems, and a high number of nights with NP was associated with more behaviour-regulation problems. No significant correlations were found between specific characteristics of enuresis and quality of life. Details are demonstrated in Table. The children were recruited from a tertiary referral centre, which resulted in selection bias. Moreover, NP was defined as a urine output exceeding 100% of the expected bladder capacity for age (EBC), and not according to the expert-opinion-based International Children's Continence Society norm of 130% of EBC. The definition for NP of a urine output exceeding 100% of the EBC is more in line with the recent findings of the Aarhus group. For children with MNE and associated NP, a high comorbidity with the predominantly inattentive presentation of ADHD was demonstrated. Children experienced problems with daytime functioning in relation to their wetting problem at night. According to the teachers, a low maximum voided volume was associated with more attention problems, and a high number of nights with NP was associated with more behaviour-regulation problems. Although comorbidity is still the appropriate word to use, the observation favours a more complex pathogenesis of enuresis with a common pathway in the central nervous system, including: neurotransmitters, influencing neuropsychological functioning as well as sleep, circadian rhythm of diuresis and bladder function control. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Ryan, Denise S; Sia, Rose K; Stutzman, Richard D; Pasternak, Joseph F; Howard, Robin S; Howell, Christopher L; Maurer, Tana; Torres, Mark F; Bower, Kraig S
2017-01-01
To compare visual performance, marksmanship performance, and threshold target identification following wavefront-guided (WFG) versus wavefront-optimized (WFO) photorefractive keratectomy (PRK). In this prospective, randomized clinical trial, active duty U.S. military Soldiers, age 21 or over, electing to undergo PRK were randomized to undergo WFG (n = 27) or WFO (n = 27) PRK for myopia or myopic astigmatism. Binocular visual performance was assessed preoperatively and 1, 3, and 6 months postoperatively: Super Vision Test high contrast, Super Vision Test contrast sensitivity (CS), and 25% contrast acuity with night vision goggle filter. CS function was generated testing at five spatial frequencies. Marksmanship performance in low light conditions was evaluated in a firing tunnel. Target detection and identification performance was tested for probability of identification of varying target sets and probability of detection of humans in cluttered environments. Visual performance, CS function, marksmanship, and threshold target identification demonstrated no statistically significant differences over time between the two treatments. Exploratory regression analysis of firing range tasks at 6 months showed no significant differences or correlations between procedures. Regression analysis of vehicle and handheld probability of identification showed a significant association with pretreatment performance. Both WFG and WFO PRK results translate to excellent and comparable visual and military performance. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
2017-01-01
Nocturnal insects have evolved remarkable visual capacities, despite small eyes and tiny brains. They can see colour, control flight and land, react to faint movements in their environment, navigate using dim celestial cues and find their way home after a long and tortuous foraging trip using learned visual landmarks. These impressive visual abilities occur at light levels when only a trickle of photons are being absorbed by each photoreceptor, begging the question of how the visual system nonetheless generates the reliable signals needed to steer behaviour. In this review, I attempt to provide an answer to this question. Part of the answer lies in their compound eyes, which maximize light capture. Part lies in the slow responses and high gains of their photoreceptors, which improve the reliability of visual signals. And a very large part lies in the spatial and temporal summation of these signals in the optic lobe, a strategy that substantially enhances contrast sensitivity in dim light and allows nocturnal insects to see a brighter world, albeit a slower and coarser one. What is abundantly clear, however, is that during their evolution insects have overcome several serious potential visual limitations, endowing them with truly extraordinary night vision. This article is part of the themed issue ‘Vision in dim light’. PMID:28193808
Mobile phone related-hazards and subjective hearing and vision symptoms in the Saudi population.
Meo, Sultan A; Al-Drees, Abdul M
2005-01-01
Over the past decade utilization of mobile phones has dramatically increased. They are now an essential part of business, commerce, and communication, however, their use may lead to health problems. Therefore, the present study was designed to investigate a link between the use of mobile phones and hearing and vision symptoms in the Saudi population and also to contribute to the increase in social awareness of health problems associated with the use of these devices. A total of 873 (57.04% of males and 39.86% of females) subjects using mobile phones were invited to participate in the presented study. A structured questionnaire was distributed among them to collect a detailed medical history. The Chi-square test was employed to observe the relationship between duration of calls and hearing and vision complaints. The present study showed an association between the use of mobile phones and hearing and vision complaints. About 34.59% of problems were related with impaired hearing, ear ache and/or warmth on the ear, and 5.04% of complaints with the decreased and/or blurred vision. It is concluded that the use of mobile phone is a health risk factor, and thus it is suggested that excessive use of mobile phones should be avoided and social awareness increased through health promotion activities, such as group discussions or public presentations and via electronic and printed media sources.
Disparities in access to medical care for individuals with vision impairment.
Spencer, Christine; Frick, Kevin; Gower, Emily W; Kempen, John H; Wolff, Jennifer L
2009-01-01
We investigated the relationship between blindness and vision impairment and access to medical care. Pooled data from the Medical Expenditure Panel Survey (MEPS) years 2002-2004 were used to identify non-institutionalized individuals over the age of 40 with either self-reported blindness, vision impairment, or no vision impairment (n = 40,643). Differences in access to care measures by vision status were assessed, after adjusting for the complex sampling design of the MEPS, using either two-sided z-tests or two-sided t-tests. Individuals with blindness and vision impairment report having more access problems related to cost of care, availability of insurance coverage, transportation issues, and refusal of services by providers, although they do not report lower rates of having a usual source of care compared to those without vision impairment. The results suggest that access to care for individuals with blindness and vision impairment is problematic, for reasons that are amenable to policy interventions.
Sleep Strategies of Night-Shift Nurses on Days Off: Which Ones are Most Adaptive?
Petrov, Megan E; Clark, C Brendan; Molzof, Hylton E; Johnson, Russell L; Cropsey, Karen L; Gamble, Karen L
2014-01-01
To determine the off-shift sleep strategies of bi-ethnic night-shift nurses, the relationship between these sleep strategies and adaptation to shift work, and identify the participant-level characteristics associated with a given sleep strategy. African-American and non-Hispanic White female, night-shift nurses from an academic hospital were recruited to complete a survey on sleep-wake patterns (n = 213). Participants completed the standard shiftwork index and the biological clocks questionnaire to determine sleep strategies and adaptation to night-shift work. In addition, chronotype was determined quantitatively with a modified version of the Munich ChronoType Questionnaire. Most participants worked ~3 consecutive 12-h night-shifts followed by several days off. Five sleep strategies used on days off were identified: (a) night stay, (b) nap proxy, (c) switch sleeper, (d) no sleep, and (e) incomplete switcher. Nap proxy and no sleep types were associated with poorer adaptation to night-shift work. The switch sleeper and incomplete switcher types were identified as more adaptive strategies that were associated with less sleep disturbance, a later chronotype, and less cardiovascular problems. Behavioral sleep strategies are related to adaptation to a typical night-shift schedule among hospital nurses. Nurses are crucial to the safety and well-being of their patients. Therefore, adoption of more adaptive sleep strategies may reduce sleep/wake dysregulation in this population, and improve cardiovascular outcomes.